Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D12-302 - DHS - 2 OFFICES
DEPARTMENT OF HOMELAND SECURITY 12500 TUKWILA INTERNATIONAL BL D12-302 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 7340600602 Permit Number: D12-302 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Issue Date: 09/26/2012 Suite No: Permit Expires On: 03/25/2013 Project Name: DEPARTMENT OF HOMELAND SECURITY Owner: Name: INTERNATIONAL GATEWAY EAST LLC Address: 12201 TUKWILA INTL BLVD 4TH FLR , SEATTLE WA 98168 Contact Person: Name: JOHN HUGHES Address: 22619 NE 202 ST , WOODINVILLE WA 98077 Contractor: Name: HUGHES CONSTRUCTION Address: 22619 NE 202 ST , WOODINVILLE WA 98072 Contractor License No: HUGHEC*011MT Lender: Name: SELF FUNDED - DEPT OF HOMELAND SECURITY Address: Phone: 206 730 -6577 Phone: 425 - 7878 -7901 Expiration Date: 01/25/2013 DESCRIPTION OF WORK: BUILD TWO NEW OFFICES INSIDE EXISTING TENANT .AREA. NON - STRUCTURAL WORK INCLUDES TWO DOOR FRAMES AND HARDWARE. Value of Construction: $12,500.00 Fees Collected: $559.07 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: IB Occupancy per IBC: 0008 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -302 Printed: 09 -26 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: N N Water Main Extension: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Number: 0 Start Time: Volumes: Cut 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non - Profit: N Public: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pr construction or the performance of work. to this pe Signatur e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit and agree to the conditions attached Print Name: Date: 9.2-&--/z__ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: * * *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Thkwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D12 -302 Printed: 09 -26 -2012 7: All construction shall be done in confornie with the approved plans and the require of the International Building Code or International Residential (�, International Mechanical Code, Washingt ate Energy Code. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 nun). (IFC 906.7 and IFC 906.9) 15: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 17: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (1FC 1008.1.8.1) 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 22: .Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 23: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 24: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 25: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer doc: IBC -7/10 D12-302 Printed: 09 -26 -2012 licensed by the State of Washington and ap ed by the Fire Marshal prior to submittal to a Fire Prevention Bureau. No sprinkler work shall commence out approved drawings. (City Ordinance N 7). 26: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 27: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2328) 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 29: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 30: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 32: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -302 Printed: 09 -26 -2012 CITY OF TUKJOA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Building Pea Project No. Date Application Accepted: gate Application Expires:. -1. (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 11bc.o -Clot King Co Assessor's Tax No.• Site Address: / ZSOD n ip Lp 'gyp jl)F�TIO,�Ya(.T�/C$uite Number: Floor: Tenant Name: Deft" UX Me»r MOrot/.Al.5o 06 PROPERTY OWNER Company Name: II lol,ve--; Coubi_ Il 0k) Name: SR CC.p:e,at toA) Address:.Z.yte t 9 ort. 710L� w ewr , AddressiZZ.,( IuN.tna )1..4- 1wiEe.1r►-ToNAi. D City: ERt t t E State: 00 , Zip4$1 iz CONTACT PERSON — person receiving all project communication Company Name: II lol,ve--; Coubi_ Il 0k) NameJOH Cityl.„ s State: Wit, Zip:��� U� ploys lL� 1 Address:.Z.yte t 9 ort. 710L� w ewr , Contr Reg No44 G ms, (J0 ©t !M Exp Date: t t9 X13 City:,36api N VI 61.1 State: wit Zip: (6011 Phone: 2.0 10 136_ 65 77 Fax: ,.1 Email: ,..7 14 i R b 9 0 E r'n t l. ticNtl Email: GENERAL CONTRACTOR INFORMATION Company Name: II lol,ve--; Coubi_ Il 0k) Address: 11 t i Na 1,07-U° Cityl.„ s State: Wit, Zip:��� U� ploys lL� 1 Phone;. u i 30 _ (mc5'11 Fax: Contr Reg No44 G ms, (J0 ©t !M Exp Date: t t9 X13 Tukwila Business License No.: N f 00O ljy\q-1 H:Wpplications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh New Tenant: ❑ Yes 19-::14o ARCHITECT OF RECORD Name: Company Name: �0 P e- psi, to )6 Company Name: Architect Name: L.-t 19 Address: /37,40 s- pt nv e ,11 'leo City: gizoli t i C State: LA A- , Zip:q ,.1 Phor 1p 581- lilt, FaxZa1i 431 - Z/ ZZ, Email: City: ENGINEER OF RECORD Name: 0610- '�� � �� Company Name: she- 19 Engineer Name: Address: City: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: 0610- '�� � �� of she- 19 Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATIO 111206- 431 -3670 oaa Valuation of Project (contractor's bid price): $ ' � Existing Building Valuation: $ Two 14? AA0 A.) t,7 wx-.. AJ /up 1 Tkio • 1 Describe the scope of work (please provide detailed information): / Al 61 a a L (bIr! Ai fo / `NA-Nk r , GEA Will there be new rack storage? ❑ ....Yes 1:0-240 If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: tr Compact: Handicap: Will there be a change in use? ❑ Yes $i No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: [� Sprinklers [ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docc Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 3116 5c1 5-7---( .� 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: tr Compact: Handicap: Will there be a change in use? ❑ Yes $i No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: [� Sprinklers [ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docc Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN Signa OR AUTHORIZED AGENT: Date: q' %O • ZO!°1— Print Name: ffJ AG:0 gs Day Telephone: 71) (D 73e '1057 7 Mailing Address: iZ4o/ q ZczYD e ' H:Wpplications\Forms- Applications On Line12012 Applications\Perrnit Application Revised - 2- 7- 12.docx Revised: February 2012 bh OaDIIUv,L(.+r City WA • State Zip Page 4 of 4 PUBLIC WORKS PERMIT INFTION — 206 -433 -0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate Septic System: ❑ On -site Septic System — For , t -site septic system, provide 2 copies of a current septic desi pproved by King County Health Department. ❑ ...Valley View ❑ ...Sewer Availability Provided ❑... Highline 0... Renton 0... Renton Submitted with Application (mark oxes which apply): ❑ .. Civil Plans (Maximum Paper — 22" x 34 ") ❑ .. Technical Information Report (Sto Drainage) ❑ .. Bond ❑ ... Insurance ❑... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for less than 7 ours 1=1.. Right -of -way Use - No Disturbance ❑ .. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑...Geotechnis<'_ Report ❑ ... Mainte i,_: ce Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) ❑ `' ight -of -way Use - Profit for less than 72 hours ...Right-of-way Use — Potential Disturbance ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic W ❑... Work in Flood Zone 0... Storm Drainage .A.:i don Septi •'.rbCut avement Cut . Looped Fire Line ❑ .. Permanent Water Meter Size (1) " WO # ❑ .. Temporary Water Meter Size " WO # ❑ .. Water Only Meter Size " WO # ❑ .. Sewer Main Extension .... Public ❑ Private ❑ ❑ .. Water Main Extension ... Public ❑ Private ❑ (2) >, (2) FINANCE INFORMATI ❑.. 0... Grease Interceptor ❑... Channelization 0... Trench Excavation ❑ ... Utility Undergrounding WO # (3) " WO # WO# (3) " WO# duct Water Meter Size " Fire Line Size at Prope 4; Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthl Service '' lin to Name: Mailing A. dress: Zip Day Telephone: Water Meter Refund/Billing; Name: Mailing Address: City State Day Telephone: City State Zip H: 1Applications\Forms- Applications On Line12012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 3 of 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 7340600602 Permit Number: D12-302 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 09/10/2012 Applicant: DEPARTMENT OF HOMELAND SECURITY Issue Date: Receipt No.: R12 -02703 Payment Amount: $340.60 Initials: JEM Payment Date: 09/26/2012 12:29 PM User ID: 1165 Balance: $0.00 Payee: HUGHES CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3412 340.60 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 336.10 640.237.114 4.50 Total: $340.60 doc: Receiot -06 Printed: 09 -26 -2012 • 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 7340600602 Permit Number: D12 -302 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 09/10/2012 Applicant: DEPARTMENT OF HOMELAND SECURITY Issue Date: Receipt No.: R12 -02559 Payment Amount: $218.47 Initials: JEM Payment Date: 09/10/2012 09:20 AM User ID: 1165 Balance: $340.60 Payee: HUGHES CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3404 218.47 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 218.47 Total: $218.47 doc: Receiot -06 Printed: 09 -10 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 op (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 DIZ -3o - Prt: rJe •�i Typ f Inspecti n: A'tJk �VI -\ W.)1%1.- Addresses i2_5 a0 -r-a"--- Date Call d: SJS- G (.pA - Special Instructions: 0 3 (1 Date Wanted:.{ �??'1.• Requester: i Phone No: (1— -7 3 A ° -IC1-C 77 Approved per applicable codes. Corrections required prior to approval. COMMENTS: P efits07— Inspector: a1.._. A, ■ F-7 REINSPECTION FEE REQUIRED. Prior to nex inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date4 ` ( 3 INSPECTION RECORD Retain a copy with permit. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 t Oa -302_ Project: T ( tJP pA ( . m LI' A13 Type Inspec�ti n: (, , e 'f 1 x. TA •• d " ` t t`'a . /ICs Addrest:— . (25 DO `Tr -B Date Called: Special Instructions: Date Wanted: 1 -.4 -(3 a.m. (pm, Requester: -' Phone No: r7,i) (v - `73 d .. 65 ) ElApproved per applicable codes. El Corrections required prior to approval. 3 COMMENTS: zoo t-- Inspdctor: • r:) /U) ririor to next ins eetion .fee must be REINSPECTION FEE'REQULRED.�9 p.._:.,s.,.. paid at 6300 Southcenter Blvd., Suite 100. Call to scte.dule reinspection. Date: (3 • �_.- C. Oars 1 _ ,alnafieeare. • • • • • • • •E• r: r• INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431 -2451 Project: ✓) 04/6/+11. f7iV2) n' ?'re/ Type of Inspection: % /,)y7.; izik /e'-, Address: /0250 r11 / Date Called: Special Instructions: / // Date Wanted:. 9— 2 7 — /2 a.m p.m. Requester: Phone No: ...2.(- 7.3o -(7 77 Approved per applicable codes. Corrections required prior to approval. ri REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER N INSPECTION RECORD Retain a copy with permit t s-- ptt D ta- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: � � ! 0-471 i i Typ of Inspection: Hood & Duct: Address: /?. Suite #: Pre -Fire: Contact Person: j.- 4 Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: al. `l , Q.-- Date: 3/1 / /.S Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 ',a • T.F.D. Form F.P. 113 „�, • • - 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit W.). —30a— PERMIT NUMBERS CITY OF TUKWILA FIRE. DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: pert, c /+oz...e lea A SPCA-, I Type of Inspection: F/4 Address: /a� (ate � Suite #: * i Contact Person: Cwt Pr,e %') /t'- Special Instructions: Monitor: Phone No.: Approved per.applicable codes. COMMENTS: Corrections required prior to approval. e. Needs Shift Inspection: Cl / Sprinklers: • Fire Alarm: / Hood & Duct: Monitor: Pre -Fire: Permits: . / Occupancy Type: Inspector: Cl / Date: //_4 _b_ Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: /i',,44 1 Company Name:. VE(,4 L %tedv ■ c „ Address: S,/ '7 _7 1-h . v e _S City: S,P44.4te Word /Inspection Record Form.Doc A 1 State: 0//1. 6/11/10 Zip: c• / c T.F.D. Form F.P. 113 J. l INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit ia- c-aay 00,- 3°a- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Proj ct: ,4, WI & /4#J ecu... , Type of Inspection: -ia- Fire Alarm: A dress: /a�0 ---t. Suite #: Co tact Person: f v1" MeiSS/ef— Pre -Fire: Special. Instructions: . - . Phone No.: doL- 61,6 -74.151/ 5ii ii.53/ Approved per applicable codes. Corrections required prior to approval. COMMENTS: -F/5r Ckti'd • • Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: ' Occupancy Type: Inspector: L 5c9_,.._ Date: /0/2,6,// 7.____ Hrs.: $100.00 REINSPECT(ON FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. CaII to schedule a reinspection. rets l er Billing Address Attn: kur: Address: '*YQ(i "? S City: 5 0°'t1-Le_ Word /Inspection Record Form.Doc Company Name: (,/'C4 State: () 6/11/10 Zip: c' gicy T.F.D. Form F.P. 113 .rq. - .... • -,x AM- 2 ' -WV; ` ter... ::c s' :+: • _ r ': INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit D,2- 3'Z.. PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: OPp4 . er-r Poeile l e r .44 Sc.- ,..: ,l.y • , - Type of Inspection: ,�f,,-.•", leir+�.� /C�‘-1 , Address: /Z "va -.7-� Suite #: Contact Person: . . r Special Instructions: Phone No.: Pre -Fire: Approved per applicable codes. Corrections required prior to.approval. COMMENTS: f• Needs Shift Inspection: Sprinklers: Date: Fire Alarm: Hood & Duct: / Monitor:' Pre -Fire: Permits: Occupancy Type: i Inspector: FAV 3—, Date: /a /2_ // . Hrs.: / $100.00 REINSPECTION FEE REQUIRED: -You will receive an.invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 1 • • _•1 •; 1r • qi ,.l • '•4 1 •ie • • • • r7 • • rS •rj OPERMIT COOfiD COP PLAN REVIEW /ROUTING SLIP 0 4 n � t' r Ci�..A• �j, � � 16• 4 t'r, ; ; ;..4 �. A try 'S tl; f a =Y itf � AA6� rf . ACTIVITY NUMBER: D12 -302 ,' DATE: 09/10/12 PROJECT NAME: DEPARTMENT OF HOMELAND SECURITY SITE ADDRESS: 12500 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: M. it B I ing Division "®' Avvoiy(4- 44_ 4i- (I--u Ire Prevention 9 Plannin Division Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 09/11/12 Complete yl Incomplete n Not Applicable ❑ Comments: Permtt Center, Use Only: .: • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 7/ Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Not Approved (attach comments) n Notation: DUE DATE: 10/09/12 REVIEWER'S INITIALS: Permit Center,Use Only • .:' ' DATE: CORRECTION LETTER MAILED: Contractors or Tradespeople Pater Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HUGHES CONSTRUCTION UBI No. 600594030 Phone 4257887901 Status Active Address 22619 Ne 202Nd St License No. HUGHEC'011MT Suite /Apt. License Type Construction Contractor City Woodinville Effective Date 7/30/1999 State WA Expiration Date 1/25/2013 Zip 98072 Suspend Date County King Specialty 1 General Business Type Individual Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HUGHECI954DQHUGHES CONSTRUCTION INC Construction Contractor General Unused 3/18/2005 3/18/2007 Expired Business Owner Information Name Role Effective Date Expiration Date HUGHES, JOHN E Owner 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 WESTERN SURETY COMPANY 25320517 07/15/2002 Until Cancelled $12,000.00 07/16/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 11 Ohio Cas Ins Co BKS54810219 07/15/2012 07/15/2013 $1,000,000.00 06/26/2012 10 Ohio Security Ins Co BKS54810219 07/15/2011 07/15/2012 $1,000,000.00 06 /17/2011 9 WESTERN HERITAGE INS CO SCP0812186 07/15/2010 07/15/2011 $1,000,000.0007 /08/2010 8 WESTERN HERITAGE INS CO SCP0756049 07/15/2009 07/15/2010 $1,000,000.00 07 /09/2009 7 WESTERN HERITAGE INS CO SCP0708011 07/15/2008 07/15/2009 $1,000,000.00 07/09/2008 6 WESTERN HERITAGE INS CO SCP0659690 07/15/2007 07/15/2008 $1,000,000.00 07 /16/2007 5 AMERICAN STATES INS CO 01CG2137745 07/15/2005 07/15/2007 $1,000,000.00 06/04/2007 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 09/26/2012 GENERAL NOTES ARCH / INTERIOR ABBREVIATIONS BUILDING SUMMARY PROJECT TEAM 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT "GENERAL CONDITIONS," AND BUILDING STANDARDS AS PROVIDED BY THE BUILDING OWNER. 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT TRADES. 3. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. 4. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWING ONLY WILL NOT SATISFY THIS REQUIREMENT. 5. ALL MODIFICATIONS, REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS AUTHORIZED IN WRITING BY OWNER AND /OR ARCHITECT. 6. WITHIN FIVE (5) BUSINESS DAYS OF START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY IN WRITING BOTH THE ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD TIMES, PAYMENT OF RUSH FABRICATION OR DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION, OR DELAY OF INSTALLATION OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. 8. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS. 9. THE USE OF WORD "PROVIDE" SHALL ALWAYS MEAN, "FURNISH AND INSTALL, CONNECT, OR SECURE" AS REQUIRED. 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL INCLUDE DELIVERY LEAD TIMES OF CONSTRUCTION ITEMS, AND START AND COMPLETION DATES OF EACH PHASE. THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS. 13. ACCESS TO AND FROM THE PROJECT SITE, SPECIAL CONDITIONS, NOISY WORK, TIMING OF WORK, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, RELOCATION OF EXISTING EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC., MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. 14. ADEQUATE CLEANUP, PROTECTION AND PLACEMENT OF ANY CEILING TILES AND /OR OTHER DISRUPTION TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT THE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS. 15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: COMMON HALLWAYS, FREIGHT ELEVATOR VESTIBULES, ETC. 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 17. UPON COMPLETION OF ALL CONSTRUCTION, THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH ONE SET OF "RECORD" AS -BUILT DRAWINGS. 18. ALL MATERIALS TO BE NEW UON. 19. PATCH ALL DISTURBED AND /OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS REQUIRED FOR FINISHED APPEARANCE. 20. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY BACKING, BLOCKING, AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL FIXTURES, CASEWORK AND ALL OTHER ITEMS REQUIRING IT. 21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. 22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND REQUIRE ARCHITECT'S REVIEW PRIOR TO INSTALLATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW. 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION. SUBMIT TO ARCHITECT AT LEAST THREE (3) COPIES FOR REVIEW. 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE LIST. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. ADJ AFF ALT ALUM APC - APPROX - ARCH ACT AV BLDG BOT CAB CL CLG CLR COL CONC CONE DEMO DEPT DF DIA DIFF DIM DTL DW DWG EA EL ELEC ELEV EQ EQUIP EXT FA FD FE FEC FFE FIN - FLUOR - FLR _ FO - FOIC - FTIC FURR GA GC GL GWB HC HDW HM HR INCL INFO INSUL LAV LF MATL MAX MDF ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM ACOUSTICAL PANEL CEILING APPROXIMATE ARCHITECTURAL ACOUSTICAL CEILING TILE AUDIO VISUAL BUILDING BOTTOM CABINET CENTER LINE CEILING CLEAR COLUMN CONCRETE CONFERENCE DEMOLITION DEPARTMENT DRINKING FOUNTAIN DIAMETER DIFFUSER DIMENSION DETAIL DISHWASHER DRAWING EACH ELEVATOR ELECTRICAL ELEVATION EQUAL EQUIPMENT EXTERIOR FIRE ALARM FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR ELEVATION FINISH FLUORESCENT FLOOR FACE OF FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FURNISHED BY TENANT, INSTALLED BY CONTRACTOR FURRING GAUGE GENERAL CONTRACTOR GLASS GYPSUM WALLBOARD - HANDICAPPED - HARDWARE - HOLLOW METAL (STEEL FRAME) - HOUR - INCLUDED OR INCLUDING - INFORMATION - INSULATION - LAVATORY - LINEAR FOOT - MATERIAL - MAXIMUM - MEDIUM DENSITY FIBERBOARD MECH MEZZ MFR MIN MISC MTD MTL N/A NIC NTS OC OFF OPNG OVHD P PART PERF PERIM PERP PLAM PLYWD QTY (R) RA RCP REC REF REFR REL REV RM RO RTD SCHED SF SHT SIM SPEC SPKLR SPKR SQ STD STL STOR STRL STRUC SYMM TBD TEL TEMP THK TO TOS TYP UON UPS VCT VIF W/ WC WD W/0 - MECHANICAL - MEZZANINE MANUFACTURER - MINIMUM MISCELLANEOUS - MOUNTED - METAL - NOT APPLICABLE - NOT IN CONTRACT - NOT TO SCALE - ON CENTER - OFFICE - OPENING - OVERHEAD - PAINT - PARTITION - PERFORATED - PERIMETER - PERPENDICULAR - PLASTIC LAMINATE - PLYWOOD - QUANTITY - RELOCATED - RETURN AIR - REFLECTED CEILING PLAN - RECESSED - REFERENCE - REFRIGERATOR - RELOCATE - REVISION OR REVISED - ROOM - ROUGH OPENING - RATED - SCHEDULE SQUARE FEET /FOOT - SHEET - SIMILAR - SPECIFICATION - SPRINKLER - SPEAKER - SQUARE - STANDARD - STEEL - STORAGE - STRUCTURAL - STRUCTURAL - SYMMETRICAL - TO BE DETERMINED - TELEPHONE OR TELECOM - TEMPERED - THICKNESS - TOP OF - TOP OF SLAB - TYPICAL - UNLESS OTHERWISE NOTED - UNINTERRUPTED POWER SUPPLY - VINYL COMPOSITION TILE - VERIFY IN FIELD - WITH - WATER CLOSET - WOOD - WITHOUT SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila , BUILDING DIVISION 1. PROJECT ADDRESS: DHS 12500 TUKWILA INTERNATIONAL BLVD. FIRST FLOOR TUKWILA, WA 98168 2. APPLICABLE CODES & ORDINANCES: 2009 INTERNATIONAL BUILDING CODE 2009 INTERNATIONAL MECHANICAL CODE 2009 INTERNATIONAL FUEL GAS CODE 2009 INTERNATIONAL FIRE CODE 2009 WASHINGTON STATE ENERGY CODE (WAC 51 -11) 2009 UNIFORM PLUMBING CODE 2009 NATIONAL FUEL GAS CODE (NFPA 54) 2008 LIQUEFIED PETROLEUM GAS CODE (NFPA 58) THE WASHINGTON CITIES ELECTRICAL CODE 2009 WASHINGTON STATE AMENDMENTS 2003 ICC /ANSI 117.1 ACCESSIBLE & USABLE BUILDINGS AND FACILITIES 3. GENERAL BUILDING DESCRIPTION: TYPE OF CONSTRUCTION: IB FIRE RESISTIVE SYSTEM: SPRINKLERED PER NFPA13 QUICK RESPONSE HEADS OCCUPANCY TYPE: 'B' OFFICE 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: SHAFT ENCLOSURES: 2 HOURS EXIT STAIR ENCLOSURES: 2 HOURS CORRIDORS: 1 HOUR 5. EXITS: APPROXIMATE AREA OF CONSTRUCTION: 375 SQFT TOTAL APPROXIMATE SUITE AREA: 3,856 SQFT TOTAL APPROXIMATE FLOOR AREA: 34,059 SQFT OCCUPANT LOAD FACTOR: 100 NUMBER OF TOTAL PROPOSED OCCUPANTS: 39 NUMBER OF EXITS REQUIRED: 2 REQUIRED; 2 PROVIDED MINIMUM EGRESS WIDTH REQUIRED: 3' -8" COMMON PATH OF EGRESS TRAVEL: 100' SPRINKLERED PER NFPA13 1014.3X1 6. PROJECT DESCRIPTION: NON- STRUCTURAL INTERIOR TENANT IMPROVEMENT. WORK INCLUDES DOORS AND FINISHES. NEW PARTITIONS, REVISIONS No changes shell be made to the scope of work without prior approval of Tukwila Build;ng Division NOTE: Revisions will require a new glen submittal and may include additional Wan rev :"! Gies. TENANT: DHS 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WA 98168 ARCHITECT /DESIGNER: Burgess Design, Inc. 1326 - 5th Avenue, Suite Seattle, Washington 98101 Tel: 206.587.7120 Fax: 206.587.7122 ATTN: Kip Kolodziejski GENERAL CONTRACTOR: TBD PLUMBING ENGINEER: TBD - Bidder Design Build by G.C. MECHANICAL ENGINEER: 500 TBD - Bidder Design Build by G.C. BUILDING MANAGER: Sabey Corporation 12201 Tukwila International Blvd., Seattle, WA 98168 Tel: 206.281.8700 Fax: 206.281.0920 ATTN: Sarah Marquez Ste 400 ELECTRICAL ENGINEER: TBD - Bidder Design Build by G.C. FIRE /LIFE SAFETY ENGINEER: TBD - Bidder Design Build by G.C. PLUMBING, MECHANICAL, ELECTRICAL, LIFE SAFETY PERMITS UNDER SEPARATE SUBMITTALS. LEGAL DESCRIPTION / PARCEL NO. STREET MAP PARCEL NUMBER:102304- 9084 -07, 102304- 9080 -01, 734060 - 0602 -03 FOR LEGAL DESCRIPTION SEE G.0.3 DRAWING INDEX `DRAWING ISSUED 0 of 0 X X GENERAL G.0.0 COVER SHEET / PROJECT INFORMATION G.0.1 PROJECT NOTES X G.0.2 SITE PLAN G.0.3 LEGAL DESCRIPTION X ARCHITECTURAL / INTERIORS A.2A.1 CONSTRUCTION PLAN x A.9.1 DOOR SCHEDULE / DETAILS FVLili co v Permit No.. Dtt-il • rviaw approval is su issions. r i of construction documents does not authorize DEFINITIONS AND DIMENSIONS KEY PLAN / FLOOR PLATE - 1":25' °cation of anv adopted code or ordinance_ Recd &l}t SYMBOLS ELEVATION REFERENCE SYMBOL U DETAIL ID D SHEET NO. SECTION REFERENCE SYMBOL DETAIL REFERENCE SYMBOL COLUMN AND /OR GRID LINE SYMBOL DIMENSION LINE: 20' - 0 L ANGLE (§ AT CENTERLINE 0 INDICATES FINISHED SURFACES TO ALIGN DRAWING TITLE BAR DETAIL IDENTIFICATION DRAWING TITLE GRAPHICAL SCALE FLOOR ELEVATION SYMBOLS 92' -O" +1' -0" NOMINAL FLOOR ELEVATION HEIGHT (ABOVE /BELOW) BUILDING SPACE / ROOM ID OFFICE SPACE NAME SPACE NUMBER 1127 DOOR SYMBOL DOCUMENT SHEET SYMBOL KEYED SHEET NOTES GLAZING SYMBOL REVISION NUMBER A. DEFINITIONS: 1. "TYPICAL" OR *TYP" INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. 2. "SIMILAR" OR "SIM." INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 3. AS REQUIRED" INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS. 4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE, AND PLUMB RELATION ADJACENT MATERIALS. 5. "CLEAR" INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF PARTITIONS. B. DIMENSIONS: 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING CONSTRUCTION, CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED. 2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING PRIORITY ORDER. A. STRUCTURAL DRAWINGS B. LARGE SCALE DETAILS C. SMALL SCALE DETAILS D. ENLARGED PLANS AND SECTIONS E. FLOOR PLANS 3. MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE REQUIREMENTS SHALL BE MAINTAINED. 4. FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE NOTED.. 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR - "AFF ". 6. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC CEILING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES, UNLESS OTHERWISE NOTED. 7. DOCUMENTS ARE DRAWN DIAGRAMATICALLY, AND SCALED DIMENSIONS ARE APPROXIMATE. DIMENSIONS SHALL INDICATE REQUIRED SIZE, CLEARANCES, AND RELATIONSHIPS ARE INDICATED BY DIMENSIONS AS NOTED. DHS 12500 TUKWILA INTERNATIONAL BLVD. TUKWILA, WA 98168 Copy and ins is acknowledged: City Of Tiikwila BUILDING DIVISION AREA OF WORK XIT ALL EXITS ARE EXISTING Tenant: DHS 12500 TUKWILA INTERNATIONAL BLVD. FIRST FLOOR SEATTLE, WA 98168 4 L CORPORATION A Tenant Improvement for: SABEY CORPORATION 12201 TUKWILA INT'L BLVD FOURTH FLOOR SEATTLE, WA 98168 -5121 • •' burgess design `interiors Q architecture 1326 Fifth Avenue .Suite 400 .Seat le Washington 98141 T:0061587.7120 F:(206)587 7122 All reproduction & intellectuol property rights reserved c 2012 Approved by: Date: CONSTRUCTION WORK SHALL NOT PROCEED UNTIL THE BUILDING OWNER / REPRESENTATIVE AND BUILDING TENANT HAVE GIVEN THEIR APPROVAL TO THESE CONSTRUCTION DOCUMENTS. APPROVAL BY THESE PARTIES SHALL BE INTERPRETED AS APPROVAL OF DRAWINGS FOR CONTENT, FINISH SELECTIONS, SCOPE OF WORK, AND ALL DIMENSIONS REGARDED BY EITHER PARTY AS BEING NECESSARY TO THEIR OPERATIONS, USE OF THE SPACE, FURNISHINGS, AND TENANT EQUIPMENT AND FURNITURE INSTALLATIONS. CONSTRUCTION AND /OR INITIATION OF CONSTRUCTION, AUTHORIZED BY THE BUILDING OWNER FROM THESE CONSTRUCTION DOCUMENTS, SHALL BE INTERPRETED BY THE DESIGNER AS APPROVAL IN FULL OF THESE CONSTRUCTION DOCUMENTS BY BOTH THE BUILDING OWNER / REPRESENTATIVE AND THE TENANT. Professional seal tclrUclv�;,,. CITY OF TIIKI I. SEP 10 2012 PERMIT CENTER No. Issue Description Date PERMIT SET 09.07.12 Drawn by: MK Project No: 12.SB04.00 Reviewed by: KK COVER SHEET / PROJECT INFORMATION Original drawing is 24" x 36 ". Scale entities accordingly if reduced G.0.0 PROJECT NOTES 1. THESE PROJECT NOTES ARE GENERIC IN NATURE. CONTRACTORS INSTRUCTIONS FOR CONSTRUCTION ADMINISTRATION MAY VARY BASED ON THE CONTRACT BETWEEN BUILDING MANAGEMENT AND TENANT. VERIFY WITH BUILDING MANAGEMENT ALL CONSTRUCTION REQUIREMENTS AND CONSTRUCTION ADMINISTRATION RESPONSIBILITIES. THE DESIGNER MAY NOT HAVE CONSTRUCTION ADMINISTRATION OBLIGATIONS. 2. PLUMBING, ELECTRICAL, MECHANICAL & LIFE SAFETY SHALL BE PERFORMED UNDER THE DESIGN /BUILD CONTRACT. ALL WORK SHALL BE TO CODE. ANY INFORMATION ON THESE DRAWINGS ARE FOR REFERENCE AND SCHEMATIC DESIGN ONLY. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF THE DESIGN. VERIFY REQUIREMENTS OF BUILDING MANAGEMENT AND TENANT. REVIEW OF SHOP DRAWINGS, IF APPROPRIATE, IS FOR AESTHETIC REASONS ONLY. 3. VERIFY BUILDING STANDARDS WITH BUILDING MANAGEMENT WHEN WORKING IN SUITES WITH NON BUILDING STANDARD ELEMENTS. VERIFY PREFERRED DETAILING OF THESE ELEMENTS WITH BUILDING MANAGEMENT. 4. VERIFY ALL RULES, GENERAL CONDITIONS AND SPECIALIZED BUILDING REQUIREMENTS WITH THE BUILDING MANAGEMENT. 5. VERIFY LEED REQUIREMENTS WITH BUILDING MANAGEMENT. DMSION I - GENERAL CONDITIONS 01010 SUMMARY OF WORK 1. GENERAL DESCRIPTION OF THE PROJECT: NON- STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE, UON. 2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS "BUILDING STANDARD" ON THE PLANS, THE CONTRACTOR SHALL SO ADVISE BURGESS DESIGN WITHIN TEN (10) DAYS OF THE CONTRACTOR'S RECEIPT OF THE PLANS SO THAT BURGESS DESIGN MAY MAKE ALTERNATE SELECTIONS. 3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES, AND IS RESPONSIBLE FOR ALL ROUGH -IN CONNECTIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. 4. FIRE /EMERGENCY SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, SPRINKLER MODIFICATIONS, FIRE EXTINGUISHER PLACEMENT, AUDIBLE ALARMS, SMOKE AND HEAT DETECTORS, STROBES, AND EXIT SIGN PLACEMENT. 5. ALL DESIGN BUILD INFRASTRUCTURE SHALL BE UNDER A SEPARATE PERMIT BY CONTRACTOR. 6. WORK NOT INCLUDED: CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE SPECIFICATIONS AND SHOWN ON THE PLANS EXCEPT FOR THE ITEMS INDICATED "N.I.C." (NOT IN CONTRACT), SUCH AS TELEPHONE AND DATA CABLES, OFFICE FURNITURE, EQUIPMENT AND MOBILE KITCHEN APPLIANCES. 7. CONTRACTOR TO PROVIDE ALL FIRE /EMERGENCY SYSTEMS AS REQUIRED BY ALL APPLICABLE CODES. FIRE /EMERGENCY SYSTEMS INCLUDE BUT NOT LIMITED TO SPRINKLER MODIFICATIONS, FIRE EXTINGUISHERS, AUDIBLE ALARMS, STROBES, SPRINKLERS, SMOKE AND HEAT DETECTORS, AND EXIT SIGNS. 8. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED. 9. ANY MATERIAL USED IN CONSTRUCTION SHALL MEET CURRENT FLAME CODE REGULATIONS. 10. ALL ELECTRICAL, PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHALL COMPLY WITH THE BUILDING SHELL STANDARD SPECIFICATIONS. 11. THE GENERAL CONTRACTOR SHALL LAY OUT THE WORK IN CONFORMITY WITH THE REQUIREMENTS OF CONTRACT DOCUMENTS, AND WILL BE HELD RESPONSIBLE FOR PROPER ESTABLISHMENT AND MAINTENANCE OF ALL LINES AND DIMENSIONS. BEFORE DOING AND WORK, THE GENERAL CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AND CONDITIONS AT THE SITE AND NOTIFY THE ARCHITECTS OF ANY DISCREPANCIES. 12. THE CONTRACTORS SHALL USE DIMENSIONS ONLY. DO NOT SCALE PLANS. ALL DIMENSIONS ARE TO FINISHED FACE UNLESS OTHERWISE NOTED. 13. MATERIALS: ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY MANUFACTURERS. ALL LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURER AND QUALITY UNLESS OTHERWISE SPECIFIED. ALL MATERIAL, EQUIPMENT AND FIXTURES SHALL BE CODE WORTHY WITH ALL PROPER JURISDICTIONAL APPROVALS. DMSION II - SITE WORK 02050 - DEMOLITION 1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ALL ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF ALL DEMOLITION WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN. 2. DEMOLITION OF TELEPHONES, ELECTRICAL, VOICE /DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED CABLING TO BE REMOVED FROM TENANT SPACES BELOW. 3. DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. 4. ALL EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION NEGOTIATED BY THE PRICING PLAN / SPACE PLAN WITH WORK LETTER SHALL BE REMOVED, RELOCATED, OR KEPT FLUSH IN CEILING, WALL, OR FLOOR AS REQUIRED. 5. ALL DAMAGED, ALTERED OR REWORKED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH ". 6. CONTRACTOR SHALL PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUST AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. DMSION VI - ARCHITECTURAL CARPENTRY AND CASEWORK 06100 - ROUGH CARPENTRY 1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS, BUCKS, NAILERS, BACKING, FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. AS DETAILED. 06200 - FINISH CARPENTRY 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED. 06400 - ARCHITECTURAL WOODWORK AND CASEWORK 1. CABINET CONSTRUCTION: COMPLY WITH THE A.W.I. ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR CUSTOM GRADE WORK. CABINETS SHALL BE FLUSH CONSTRUCTION. 2. PROVIDE PARTICLE BOARD, MED. DENSITY, WEIGHING <40 LB. /CU. FT., AT LEAST 3/4" THICK. 3. CABINET HARDWARE: FULL EXTENSION DRAWER GLIDES, STAINLESS STEEL CABINET PULLS, US32D FINISH, AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, UON IN ELEVATIONS / DETAILS, OR PER BUILDING STANDARD. 4. PLASTIC LAMINATE: HIGH - PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, AND FORMICA, UON. LAMINATE TO BE GENERAL - PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL. 5. INTERIOR CABINET SURFACES & SHELVES TO BE OF PREFINISHED BOARD WITH POLYESTER OVERLAY, UON. 6. SHELF EDGING TO BE P- LAM, UON. 7. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. DMSION VIII - DOORS AND WINDOWS 08210 - WOOD DOORS 1. PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS. 2. DOOR SCHEDULE SPECIFIES FINISH (BOTH SIDES OF DOOR) AND FRAME, UON. 3. DOORS SHALL BE PRE - MACHINED FOR HARDWARE PER HARDWARE SCHEDULE. 4. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 5. CONTRACTOR SHALL REVIEW SUITE FOR DOOR STYLE CHANGES AND VERIFY WITH ARCHITECT AND BUILDING MANAGEMENT THE DOOR STYLE TO MATCH IF A VARIATION IS PRESENT. 08710 - FINISH HARDWARE 1. FINISH AND SPECIALTY HARDWARE INCLUDES ALL ACCESSORIES, TOOLS, AND FASTENERS REQUIRED FOR HARDWARE INSTALLATION AND MAINTENANCE. ITEMS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO COMPLETE THE WORK, SHALL BE FURNISHED MATCHING IN QUALITY AND FINISH OF SPECIFIED IN SIMILAR LOCATIONS. 2. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDULE. 3. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE TWO (2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. ALL KEYS TO BE TAGGED WITH ROOM NUMBERS. CONFIRM QUANTITY WITH BUILDING MANAGEMENT. 4. SUBMIT HARDWARE SCHEDULE WITH CATALOGUE CUT SHEETS FOR ARCHITECT REVIEW. 5. ALL DOORS SHALL HAVE A MINIMUM OF 1 -1/2 PAIR OF BUTT HINGES, ONE LATCHSET OR LOCK SET, AND ONE DOOR STOP TO MEET ACCESSIBILITY REQUIREMENTS. 6. ALL HARDWARE SHALL BE COMMERCIAL GRADE AND RATED AT REQUIRED ASSEMBLIES. 7. PROVIDE CLOSERS PER HARDWARE SCHEDULE AND AT ALL RATED ASSEMBLIES. 8. ALL HARDWARE SHALL MATCH BUILDING STANDARD IN STYLE AND FINISH. 9. SET UNITS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND OPERATION. 10. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERY UNIT. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE APPLICATION MADE. 11. PROVIDE PROPER SMOKE GASKETS AT RATED ASSEMBLIES. 12. MATCH BUILDING STANDARD SPECIFICATIONS AND FINISHES. 13. THE FOLLOWING UL LISTINGS ARE REQUIRED ON THE FOLLOWING HARDWARE: PANIC HARDWARE - UL #305 FIRE EXIT HARDWARE - UL #106 & UL #305 ELECTROMAGNETIC LOCK HARDWARE - UL # FWAX -S -A -6635 THE CRASH BAR MUST BE AT LEAST 1/2 OF THE DOOR WIDTH AND OPEN FORCE NO MORE THAN 15 LBS. VERIFY WITH BUILDING STANDARD & MANAGEMENT AND INFORM ARCHITECT IF BUILDING STANDARD DOESN'T COMPLY. 08810 - GLASS 1. ALL GLASS AT SIDELIGHTS AND DOORS SHALL BE 1/4" TEMPERED SAFETY GLAZING, UON. 2. CONTRACTOR SHALL VERIFY GLASS THICKNESS IS APPROPRIATE FOR DIMENSIONS AND SPANS. 3. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS. GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS. IF GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARD, THEY SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 4. RATED GLASS (CERAMIC) RELITE SHALL BE PREMIUM POLISHED FINISH. DMSION IX - FINISHez 09250 GYPSUM DRYWALL AND METAL STUDS 1. INCLUDE NECESSARY MATERIALS, LABOR AND ACCESSORIES FOR THE INSTALLATION OF ALL PARTITIONS AS SHOWN IN THE PLANS. 2. "WALL SURFACES" MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC. 3. ALL PARTITION HEADS SHALL MATCH BUILDING STANDARD, UON. 4. WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE BUILDING STRUCTURE, UON. 5. SEISMIC BRACING: PROVIDE SEISMIC BRACING AS REQUIRED PER THE LATEST BUILDING CODES TO THE PARTITION HEADS AND CEILING GRID. 6. FRAMING STUDS: GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE WITH SHEET METAL BACKING WITHIN ALL WALLS RECEIVING CASEWORK (CABINETS, BOOKSHELVES, ETC.). VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCK IF APPLICABLE. 7. CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING, AND ELECTRICAL WORK. FIRE RATE AS REQUIRED. 8. ALL DRYWALL TO BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED. PROVIDE "M /R" TYPE DRYWALL WHERE REQUIRED BY CODE AND AT ALL TOILET ROOMS, AND BEHIND CERAMIC TILES, UON. 9. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS. INSTALL METAL EDGE TRIM WHENEVER EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI - EXPOSED. 10. PRIOR TO RECEIVING FINISH, ALL SURFACES SHALL BE PROPERLY PREPARED AS REQUIRED TO RECEIVE FINAL FINISHING AS SPECIFIED. 11. EXTEND ALL SOFFIT FRAMING TO STRUCTURE ABOVE. PROVIDE STRUCTURAL DIAGONAL BRACING AS NECESSARY. 12. PROVIDE FRAMING FOR SUSPENDED CEILING WITH SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AND AS SHOWN ON DRAWINGS. 13. USE ACOUSTICAL SEALANT AROUND ALL PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES, ETC. ON BOTH SIDES OF CROSSING /P'ENETRATING WALLS WITH ACOUSTICAL INSULATION. PENETRATIONS OF FIRE -RATED WALLS SHALL BE PROTECTED BY APPLICABLE FIRE -RATED ASSEMBLIES AND MATERIALS. 14. FIRE AND SMOKE SEPARATION ASSEMBLIES SHALL BE MARKED AS REQUIRED IN IBC SECTION 703.6. 09500 - CEILING SUSPENSION SYSTEMS. 1. PROVIDE NEW CEILING TILE, CEILING GRID AND ALL ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEILINGS AS INDICATED ON DRAWINGS. 2. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. VERIFY WITH BUILDING MANAGEMENT IF EXISTING CONDITIONS ARE SEISMICALLY BRACED OR PROVIDE PER CODE. 3. COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEILING AND THE TELEPHONE AND DATA CABLE COMPANIES WHEREVER THEIR RESPECTIVE WORK IS CONTIGUOUS. 4. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES, REGISTERS, DIFFUSERS, SPRINKLERS, AND OTHER INSERTED ITEMS. 5. ALL CUTOUTS SHALL BE CENTERED WITHIN ACOUSTIC CEILING TILE, UON. 6. ALL MATERIALS SHALL HAVE CLASS 1 FLAME SPREAD RATING AND BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND CODES. 7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL AND PERFECTLY ALIGNED WITH EACH OTHER. 8. INSTALLED SUSPENDED CEIUNGS TO BE LEVEL WITHIN A TOLERANCE OF 1/8" IN 12' -O ". ANCHOR AS REQUIRED. 9. IN AREAS OF ALTERATIONS CONTRACTOR SHALL MATCH CONDITIONS AND MAKE EVERY EFFORT TO ALIGN, LEVEL AND MATCH NEVV CEILING TO OLD. CONTRACTOR SHALL REVIEW ALL CEILINGS UPON COMMENCEMENT OF THE PROJECT AND INFORM THE BUILDING MANAGEMENT OF ANY DISCONTINUITIES IN THE CEILING WITHIN 10 DAYS. 10. ADJUST PARTITION HEAD DETAIL TO MATCH EXISTING CEILING CONDITIONS IF NECESSARY. 09530 - ACOUSTICAL TREATMENT 1. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF PARTITION HEAD ABOVE: CEILINGS FOR ALL WALLS NOTED PER PLANS. 2. NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND TWO FEET OF INSULATION ON EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID, UON. 09650 - RESILIENT FLOORING 1. PROVIDE VCT, SHEET LINOLEUM, SHEET VINYL AND RUBBER BASE AS INDICATED IN DRAWINGS. COLOR AND MANUFACTURER PER FINISH SCHEDULE. 2. PROVIDE RUBBER- REDUCING STRIPS IN COLOR TO MATCH SPECIFIED BASE. REDUCING STRIPS TO OCCUR AT ALL AREAS OF FLOOR MATERIAL TRANSITION. 3. BASE TO BE INSTALLED IN LONGEST AVAILABLE LENGTH WITH NO PIECE LESS THAN 12 ". NO JOINTS AT OUTSIDE CORNERS OR WITHIN 6" OF CORNERS. 4. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITIOUS UNDERLAY PER MFR'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 5. GENERAL CONTRACTOR SHALL APPLY FLOOR WAX TO NEW FLOORING AREAS PER MANUFACTURERS SPECIFICATION, UON. 6. UNLESS SPECIFIED ALL RUBBER BASE SHALL BE COVED BASE. 09680 CARPET 1. PROVIDE AND INSTALL COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS. 2. PREPARE SUB FLOOR WITH LIGHT WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 3. PROVIDE SEAMING DIAGRAMS FOR ARCHITECT'S REVIEW. 09900 - PAINTING AND STAIN 1. UNLESS OTHERWISE NOTED, PRIME ALL GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2) FINISH COATS OF BENJAMIN MOORE EGGSHELL FINISH LATEX PAINT OR APPROVED EQUAL, UON. PROVIDE FOR NUMBER OF PAINT COLORS AS INDICATED IN DRAWINGS. 2. FINISH DOORS, DOOR FRAMES, AND SIDELIGHT FRAMES AS INDICATED IN DRAWINGS. A) PAINTED WOODWORK TO BE FINISHED WITH ONE (1) COAT PRIMER AND TWO (2) FINISH COATS. B) SEALED WOODWORK TO BE STAINED PER FINISH SCHEDULE AND SEALED WITH A COMMERCIAL GRADE CLEAR SATIN VARNISH. 3. PAINT, FOR THE LIGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (1) COAT PRIMER AND TWO (2) FINISH COATS. GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. 4. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (1) COAT PRIMER AND TWO (2) FINISH COATS. GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES. 5. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM ALL OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME. 6. TOUCH -UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF WORK BY OTHER TRADES. 7. WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY SHALL RECEIVE THE SAME FINISH AS THE ROOM, UON. 8. ALL PAINTED SURFACES SHALL BE PREPARED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (ESPECIALLY IN REGARD TO THE PRIMING OF EXISTING SURFACES). 9. PUTTY ALL NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE APPLYING FINISH. 10. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. 11. SAND ENAMELED FINISHES APPLIED TO WOODS OR METAL BETWEEN COATS WITH FINE SANDPAPER TO PRODUCE SMOOTH FINISH. 12. MAKE FINISH WORK UNIFORM AND SMOOTH, FREE OF RUNS, SAGS, DEFECTIVE BRUSHING AND CLOGGING. MAKE EDGES OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING. DMSION XII - FURNISHINGS 1250Q_=, WINDOW TREATMENT 1. ALL EXISTING INTERIOR AND PERIMETER MINI BLINDS TO BE BAGGED AND CLEANED TO LIKE -NEW CONDITION. 2. ALL PERIMETER GLAZING TO RECEIVE BLINDS. AS INDICATED IN DRAWINGS. COORDINATE WITH BUILDING MANAGEMENT. MATCH EXISTING CONDITIONS UON. 3. ALL INTERIOR SIDELIGHTS TO RECEIVE 1" MINI - BLINDS WHERE INDICATED IN D 4. PROVIDE SAMPLE AND CUT SHEET TO ARCHITECT FOR REVIEW. 12900 - SIGNAGE 1. PROVIDE AND INSTALL ALL CODE REQUIRED SIGNAGE. DMSION XV - MECHANICAL 15400 - PLUMBING 1. PROVIDE SUPPLY, WASTE AND VENT LINES, VALVES, FITTINGS, ETC. REQUIRED DISHWASHER, REFRIGERATOR, AIR CONDITIONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER HEATERS, ETC. REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 0 2012 City of Tukwila BUILDING DIVISION 2. ALL FIXTURE INSTALLATIONS SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE NEW PLUMBING FIXTURES AS SPECIFIED PER DRAWINGS, OR PER BUILDING STANDARD, UON. 4. PROVIDE HOT AND COLD WATER TO SINKS /DISHWASHERS IF APPLICABLE. 5. ALL NEW WATER HEATERS ARE TO BE INSTALLED WITH DRIP PAN CONNECTED TO WASTE LINE. VERIFY LOCATIONS WITH BUILDING MANAGEMENT AND INSPECTORS. 6. ALL PLUMBING FIXTURES ARE TO BE INSTALLED TO MEET CURRENT GOVERNING LOCAL AND FEDERAL CODES. 7. CONTRACTOR SHALL PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 8. VERIFY WATER SUPPLY & SEWER DRAIN CAPACITY FOR ENTIRE BUILDING WILL MEET NEW CAPACITY WHEN NEW RESTROOMS ARE ADDED TO BUILDING. 15500 - FIRE PROTECTION 1. ALTER OR INSTALL FIRE PROTECTION SYSTEM PER BUILDING STANDARD, LOCAL REGULATIONS AND ORDINANCES. 2. PROVIDE ALL EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS REQUIRED BY CODE. DESIGN AND INSTALL THE SAME IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE SPRINKLERS, FIRE RATED DOORS AND FRAMES, FIRE EXTINGUISHERS, ETC. AS REQUIRED BY APPLICABLE LOCAL CODES AND LAWS. 4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITER'S LABORATORY 2A -10BC 5 -LB, MULTIPURPOSE EXTINGUISHER WITH SQUEEZE -TYPE HANDLE AND FLEXIBLE DISCHARGE HOSE WITH VISIBLE PRESSURE GAUGE, UON. 5. FIRE EXTINGUISHERS SHALL BE INSTALLED PER BUILDING STANDARD REQUIREMENTS, UON. VERIFY LOCATION WITH FIRE MARSHALL. WHEN REQUIRED BY CODE, PROVIDE 1 WALL MOUNT TYPE IN EACH SERVER ROOM OR LABORATORY. 6. DESIGN BUILD FIRE PROTECTION DRAWINGS INDICATE: A. LAYOUT, LOCATION, AND SIZE OF SPRINKLER LINES AND HEADS. B. PRESSURE REQUIREMENTS. C. SPRINKLER HEAD SPECIFICATIONS. D. LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS 7. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE HORNS AND STROBES. 8. ALL SPRINKLER HEADS SHALL BE CENTERED IN ACOUSTICAL CEILING TILE, UON. 9. USE OF NFPA 13 QUICK RESPONSE HEADS MAY BE REQUIRED. CONTRACTOR SHALL VERIFY EXTENT OF QUICK RESPONSE HEADS BY CITY FOR THIS PROJECT. 15800 - HEATING VENTILATING AND AIR CONDITIONING 1. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH ALL MATERIALS, LABOR AND ACCESSORIES FOR COMPLETE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE HVAC SYSTEM AS REQUIRED. 2. DESIGN BUILD MECHANICAL ENGINEERING DRAWINGS INDICATE: A. DUCTS, AIR MOVEMENT REQUIREMENTS, & SIZES OF GRILLES & REGISTERS. 3. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 4. HVAC CONTRACTOR TO CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS, FILTERS AND THERMOSTATS. 5. RE -ZONE, ALTER OR SEPARATE HVAC AS NECESSARY AS DIRECTED BY BUILDING MANAGEMENT FOR ALTERED SUITES. 16000 - ELECTRICAL AND TELECOMMUNICATIONS 1. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. REPLACE OUTLET COVER PLATES TO MATCH NEW FINISH IF APPLICABLE. 2. PROVIDE ALL WORK, EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL SYSTEM. PROVIDE ELECTRICAL OUTLETS PER POWER AND DATA PLAN. 3. PROVIDE MUD RING FOR DATA AND COMMUNICATION AS SHOWN ON THE POWER AND DATA PLAN. EACH MUD RING TO HAVE A MINIMUM NUMBER OF WIRE PULLS AS INDICATED ON DRAWINGS. COORDINATE DATA CABLE CONFIGURATION WITH THE TENANT. 4. ALL OUTLETS AND MUD RINGS TO BE LOCATED AT 18" AFF TO THE CENTER LINE, UON. 5. WHERE MULTIPLE DEVISES OCCUR IN A SINGLE LOCATION, ALL DEVICES SHALL BE GANGED UON. 6. ALL ELECTRICAL OUTLETS WITHIN THE CODE REQUIRED DISTANCE FROM A SINK SHALL BE ON A GROUND FAULT INTERRUPTED CIRCUIT. 7. ALL WIRING DEVICES: SHALL BE BUILDING STANDARD EXCEPT: "ISOLATED GROUND" OUTLETS SHALL BE ORANGE, "HOSPITAL GRADE ISOLATED GROUND" OUTLETS SHALL BE ORANGE WITH A GREEN DOT, "EMERGENCY" OUTLETS SHALL BE RED, AND "DEDICATED" OUTLETS FOR "CLEAN CIRCUIT" FIXTURES SHALL BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). ALL COVER PLATES SHALL BE BUILDING STANDARD FINISH, UON. VERIFY WITH BUILDING MANAGEMENT. 8. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING THE TELEPHONE SWITCH, COPIERS, COMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION DOCUMENTS. 9. COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE INSTALLATION OF TENANT'S NEW FURNITURE. 10. ALL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING, AND CONDUIT SHALL BE CONCEALED IN FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA TO BE PROVIDED BY TENANT'S VENDORS AND SHALL BE COORDINATED BY THE BUILDING MANAGER. 11. THE CONTRACTOR IS TO COORDINATE WITH THE TENANTS SUPPLIED FURNITURE SYSTEMS TO INCLUDE BUT NOT LIMITED TO: ELECTRICAL AND DATA WIRING LOCATIONS, J- BOX LOCATIONS, CONNECTIONS AND WALL MOUNTED REQUIREMENTS. 12. THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH MATERIAL TO MEET CURRENT FLAME SPREAD REGULATIONS. LOCATIONS TO BE PREPARED TO RECEIVE NEW FLOOR FINISH AS REQUIRED. FLOOR SHALL BE LEFT FLUSH. 13. ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY OF DEVICES SHOWN. SWITCHING AND CIRCUITING SHALL BE INDICATED ON SEPARATE ELECTRICAL ENGINEERING AS -BUILT DRAWINGS AND SHALL MEET OWNER'S GUIDELINES. 14. ALL TELEPHONE, ELECTRICAL, COMMUNICATION AND SECURITY WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE CODES. 15. DRAWINGS INDICATE ALL DIMENSIONS TO CENTERLINE OF TELEPHONE, ELECTRICAL, AND COMMUNICATION COVER PLATE. OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION BETWEEN EACH DEVICE. 16. BACK -TO -BACK OUTLETS ARE NOT PERMITTED. FOR ACOUSTICAL CONTROL. 17. LOCATION OF ALL WALL MOUNTED POWER AND BEFORE INSTALLATION. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED DATA DEVICES SHALL BE FIELD REVIEWED BY THE TENANT 18. ELECTRICAL ENGINEER TO PROVIDE DESIGN /BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. 19. THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER & DATA DEVICES. DOCUMENTS FOR SCOPE, TECHNICAL LAYOUT AND SPECIFICATIONS FOR EACH DIS 20. ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES. LOCATION WITH FURNITURE VENDOR. REFER TO DESIGN /BUILD CIPLINE. COORDINATE EXACT 21. COORDINATE POWER /DATA, FIRE SAFETY DEVICES & LIGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR ELEVATIONS, SYSTEM FURNITURE, FINISHES & CASEWORK. 22. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR AND LIGHT FIXTURES. COORDINATE WITH INTERIOR FINISHES AND CASEWORK. 23. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE GRILLS AND THERMOSTATS 24. RECIRCUIT, ALTER OR SEPARATE ELECTRICAL AND VOICE SYSTEM AS NECESSARY BUILDING MANAGEMENT FOR ALTERED SUITES. 16500 - LIGHTING POWER /DATA DEVICES BUILDING OWNER FOR AND AS DIRECTED BY 1. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED CEILING PLAN. ALL SWITCHES SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 48" A.F.F. TO MEET THE LATEST ACCESSIBILITY CODES AND REGULATIONS. 2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION, ALL SWITCHES SHALL BE GANGED UON. 3. WHEN WORKING IN PUBLIC CORRIDOR VERIFY SWITCHING REQUIREMENTS WITH BUILDING MANAGEMENT. 4. VERIFY WITH BUILDING MANAGEMENT SEPARATION OF SUITE SWITCHING WHEN DEMISING CONFIGURATIONS CHANGE. 5. DOWN LIGHTS SHOWN IN THE CENTER OF CEILING TILE WITHOUT DIMENSIONS ARE TO BE LOCATED IN THE CENTER OF CEILING TILE OR CENTER OF 2X2 PORTION OF 2X4 SECOND LOOK TEGULAR TILE. UON. 6. REUSE ALL EXISTING BUILDING STANDARD FLUORESCENT FIXTURES AS NEEDED PER DESIGN LAYOUT AND TO MEET LOCAL ENERGY CODE COMPLIANCE. VERIFY OR PROVIDE NEW LAMPS AND REPLACE FAULTY BALLASTS. 7. PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD PRIOR TO COMMENCEMENT OF WORK. 8. ALL OFFICE AREAS LESS THAN 300 SQ. FT. ENCLOSED BY WALLS OR CEILING - HEIGHT PARTITIONS, AND ALL MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS, PER CODE. 9. DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS INDICATE: A. CIRCUITING AND WIRING OF LIGHT FIXTURES, AND SWITCHES. B. LIFE SAFETY EQUIPMENT. C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES. D. LIGHT FIXTURE SPECIFICATIONS 10. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 11. CONTRACTOR SHALL RE- CIRCUIT AND RE- SWITCH ALL ASPECTS OF TENANT SUITE AND ADJOINING SUITES AS NECESSARY TO FULLY SEPARATE TENANT SUITE FROM OTHERS, AND PROVIDE NEW CORRIDOR, HALLWAY AND OPEN OFFICE SWITCHES AS NEEDED. 12. VERIFY SWITCHING WITH TENANT AND BUILDING MANAGEMENT. VERIFY APPROVED ENERGY CODE REQUIREMENTS OR ENERGY MANAGEMENT SYSTEM AS PART OF THE DESIGN BUILD CONTRACT. 13. PROVIDE, ALTER OR VERIFY ALL EMERGENCY EXIT LIGHTING AND ACCESS PATHWAY LIGHTING AS DIRECTED BY EXISTING CONDITIONS AND CODE REQUIREMENTS. 14. EXIT SIGNS SHALL HAVE UL #924. bl3oz Tenant: DHS 12500 TUKWILA INTERNATIONAL BLVD. FIRST FLOOR SEATTLE, WA 98168 1 L (ORPORAT A Tenant Improvement for: SABEY CORPORATION 12201 TUKWILA INTL BLVD FOURTH FLOOR SEATTLE, WA 98168 -5121 burgess design I interiors 0 architecture 1326 Fif)h Avenue. Sue 400. Seattle Washington 98101 1: (206) 582.7120 E (206) 587.71II M reproduction & intellectual property rights reserved c 2012 Professional seal rccivcu ^irV 17F TUKVr! ^ SEP 10 2012 PERMIT CENTER No. Issue Description Date PERMIT SET 09.07.12 Drown by: MK Reviewed by: KK Project No: 1 2.SB04.00 PROJECT NOTES Original drawing is 24° x 36 ". Scale entities accordingly if reduced G.0.1 10 S01'46'02 "W 107.22' POINT OF BEGINNING FOUND W 1/4 CORNER, SECTION 10, FOUND 2" IRON PIPE w/ BRASS CAP tV SOI %16'02"W 402.93' NE1/4 of THE SE1/4 AND SE1 4 OF THE SE1 /4 OF SECTION 9 AND GOV'T LOT 15 AND SW1 /4 OF THE SW1 /4 OF SECTION 10, 'T23N., R4E., W.M. CITY OF TUKWILA, KING COUNTY, WASHINGTON NI FRTH 0 20 40 60 120 SCALE: 1" = 60' so1.46'o2 "W 247.71' i FOUND CASED BRASS CAP AT INTERSECTION E. MARGINAL WAY AND SOUTH 126TH STREET N8918'S0 "W 974.56' (M) 967.45' (P) 35tH AVENUE SOQ -j 0C -04`QG Ag 1 p � 0 'L 1- . 46'02 "E -73.78' � cn NAIL & BRASS SHINER NOT FOUND, REMOVED 161TH CONSTRUCTION 7 30' t» IS 3420 8 ROBERT BERNHARDT EA5r.s1REAli 9 119.96' S • '46'02 "W '02"W 367.67' ACOss ro EXISTING BLDG 21 -05 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 0 2012 City of Tukwila BUILDING DIVISION REFER TO RECORD OF SURVE VOL. 49 OF SURVEYS, PG 127 FOR CENTERLINE S. 126114 STREET SO1'46'02 "W 10.00' N8918'50"W 20.00' ME OF ASPHALT 34TH AVENUE SOUTH MP' ail 11aliw'R` miesompagrwauessnausi DEDICA11ON TO CITY OF TUKWWLA - — �vaci�tcnU� r�1�— — —. � 1?!t7}1 ,� NJp43?J�o _ \ LOT D.8 6.9t 7 AC. BA L. /02 -05 AFN 20030327900002 Z41NE 17 WOE 01IE5T EASEMENT AFN 200O1019000140 EXISTING BLD.0 .21 -03 I 11 11 1 egg 30• ME ELECTRIC OVERHEAD AND OHOERQRO= NS1PhBUIION UNE3 EASEMENT, AFT! 8111080294 c E 260.08' 82.2' ic x BAASS OF BEARING NO1'46'02 "E 2580.05' (M) - ----SD ----- 15` WIDE WATER UNE EASEMENT "OVER LOT 7, AFN WEST LINE SECTION 10 N0146'02 "E SECTION 2580.05' (M) 0 • tat 342.12' S86'03'33 "E (R) a 4=7'47'13" L=1 .20 L 302. Pc :I A =16'18 30 R 1 61�..0-0y�.' tii 2`�;1-- .__.._.....�..,� T� �` SAY ��} µt� �! ?=- $8 4!?Pc o.., r. --!_- I" ~,._._T 8= 16'18'30" R =1146.0 1 t48' '31,17. 00 \M01 UMENl . "w 189.82 --'' _,nsr23 ■ BSS OF BPSIwiq NORTH 01'46'02' EAST, BEING THE WEST SECTION UNE OF SECTION 10, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M4 M SHOWN ON THE RECORD OF SURVEY FOR THE BOEING COMPANY, RECORDED UNDER AUDITOR'S FiLE NO. 9012199002, VOLUME 77 OF SURVEYS, AT PAGE 209, RECORDS OF KING COUNTY, WASHINGTON. NOTES 1. THIS NORTHERLY ACCESS POINT TO THE DEPARTMENT OF HOMELAND SECURITY BUILDING UES WITHIN LOT 7 AS SHOWN HERE AND ALSO UES WITHIN PARCEL "A" AS DESCRI[ D IN THE DEED UNDER AUDITOR'S FILE NUMBER 5092894 RECORDS OF KiNG COUNTY, W NGTON. THIS DEED CONVEYS AND WARRANTS TO THE STATE OF WASHINGTON THE RIGHT OF INGRESS AND EGRESS (INCLUDING ALL EXISTING, FUN E OR POTENTIAL EASEMENTS OF ACCESS, LIGHT, VIEW AND AIR) TO, FRCM AND BETWEEN THE STATE HIGHWAY (TUKWiLA INTERNATIONAL BLVD.) AN THE REMAINDER OF SAID PARCEL "A ". THIS CREATES A UMITED ACCESS AREA. ACCESS TO LOT 7 FROM TUKWttA •MITERNAiIONAL'BLVD:.REQUIRES AN ACCESS AGREEMENT FROM THE STATE OF WASHINGTON. THIS AGREEMENT IS SATISFIED BY PERMIT NUMBER 3092 ISSUED BY THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATION ON FEBRUARY 24, 2004 FOR THE TRAFFIC SIGNAL ON TUKWILA INTERNATIONAL BOULEVARD FOR THE DEPARTMENT OF HOMELAND SECURITY FACILITY. THIS NORTHERLY ACCESS POINT LIES NORTH OF THE BEGNNING POINT OF LIMITED ACCESS, WMICH IS HIGHWAY ENGINEER'S STATION 532 +00 ACCORDING TO THE DEED FILED UNDER AUDITOR'S FiLE NUMBER 8611070566, RECORDS OF KING COUNTY, WASHINGTON, AS SHOWN HEREON. 2. THIS SOUTHERLY ACCESS POINT TO THE DEPARTMENT OF HOMELAND SECURITY BUILDING UES SOUTHERLY OF ANY RIGHTS WHICH THE STATE OF WASHINGTON MAY HAVE IN REGARDS TO INGRESS AND /OR EGRESS (INCLUDING ALL EXISTING, FUTURE OR POTENTIAL EASEMENTS OF ACCESS, UGHT, VIEW AND MR), PER EXCEPTION PARAGRAPH NO. 8, PER TITLE COMMITMENT NO. 800 - 10140309 DATED AUGUST 13, 2003. THIS SOUTHERLY ACCESS POINT LIES SOUTH OF THE BEGINNING POINT OF LIMITED ACCESS, WHICH IS HIGHWAY ENGINEER'S STATION 532 +00 ACCORDING TO THE DEED FILED UNDER AUDITOR'S F?LE NUMBER 8611070566, RECORDS OF KING COUNTY, WASHINGTON. THERE ARE NO ACCESS RESTRICT1ONS•FOR THIS SOUTHERLY ACCESS POINT AS SHOWN HEREON. LEGEND ► . = FOUND SECTION CORNER AS NOTED BOO 4 = FOUND QUARTER SECTION CORNER AS NOTED =.FOUND MONUMENT AS NOTED • = FOUND 1/2 REBAR /CAP MARKED "DEA 18904" (M) = MEASURED BEARiNG/DISTANCE (C) = BEARING/DISTANCE PER CALCULA110NS (P) - BEARiNG/DISTANCE PER RECORDED PLAT 3X- GM ® O c VAN EXISTING FIRE HYDRANT EXISTING STREET LIGHT EXISTING LUMINAIRE EXISTING GAS METER EXISTING SANITARY SEWER MANHOLE EXISTING HANDICAPPED PARKING STALL EXISTING COMPACT PARKING STALL EXISiNG VAN HANDICAPPED PARKING STALL 1 FOUND 3" I.P. W BRASS CAP HI-WAY PT MON. REFER TO R —O —S VOL 37 OF SURVEYS PG 107 FOUND SW SECTION CORNER, SECTION 10, FOUND 4 "x4" CONCRETE MONUMENT W/ BRASS CAP 15 16 * ** UMITED ACCESS BEGINS AT HIGHWAY ENGINEER'S STATION 532 +00 AS SHOWN, ACCORDING TO THE DEED FILED UNDER AUDITOR'S FILE NUMBER 8611070566, RECORDS OF K•0 COUNTY. WASHINGTON. LOT 8, AS SHOWN HEREON. HAS UNRESTRICTED VEHICULAR AND PEDESTRIAN ACCESS TO TUKWILA INTERNATIONAL BLVD. SOUTH OF THIS STATION. ACCORDING TO SAID DEED. THE SOUTHERLY PROPOSED ACCESS POINT TO 1HE FUTURE DEPARTMENT OF HOMELAND SECURITY BUILDING UES SOUTH OF PARCEL "A" AS DESCRIBED IN SAID DEED. ■ EXISTING STORM CATCH BASIN —0-- EXISTING POWER POLE ▪ EXISTING GUY ANCHOR . EXISTING SIGN EXISTING GAS UNE EXISTING OVERHEAD POWER UNE EXISTING SANITARY SEWER LINE EXISTING WATER UNE EXISTING STORM DRAIN LINE —X EXISTING FENCE UNE —0 - - P(OH)- -- SS So CURB. GUTTER & SIDEWALK W/ 6" HIGH VERTICAL CURB UMITED ACCESS AREA 1 1 D I)- -3o2 Tenant: DHS 12500 TUKWILA INTERNATIONAL BLVD. FIRST FLOOR SEATTLE, WA 98168 A Tenant Improvement for: SABEY CORPORATION 12201 TUKWILA INTL BLVD FOURTH FLOOR SEATTLE, WA 98168 -5121 burgess design I interiors 0 architecture 1326 Fifth Avenue. Suite 400. Seattle Washington 98141 T:12061517.7120 F:(2061 S87.7122 All reproduction & intellectual property rights reserved c 2012 Professional seal REL;clvcv CITY OF TUKW!. SEP 1 0 2012 PERMIT CENTER No. Issue Description Dote PERMIT SET 09.07.12 Drawn by: MK Project No: 1 2.SB04.00 Reviewed by: KK SITE PLAN - NOT A LEGAL SURVEY Original drawing is 24" x 36 ". Scale entities accordingly if reduced G.0.2 NE1 /4 OF THE SE1 /4 AND SE1 /4 OF THE SE1 /4 OF SECTION 9 AND GOV'T LOT 15 AND SW1 /4 OF THE SW1 /4 OF SECTION 10, T23N., R4E., t�.11hl. CITY OF TUKWiLA, KING COUNTY, WASHINGTON TITLE NOTES 1. THE LEGAL DESCRIPTION OF THE BOUNDARY OF LOT 6 AND LOT 8 USED FOR THIS A.LT.A. SURVEY WAS PROVIDED BY TRANSNATION TITLE INSURANCE COMPANY, COMMITMENT ND. 800- 10140309 DATED JUNE 16, 2003, SUBSEQUENTLY UPDATED ON JULY 21, 2003, AND FURTHER UPDATED ON AUGUST 13, 2003. THE LEGAL DESCRIPTION OF THE BOUNDARY OF LOT 7 USED FOR THIS A.L.T.A. SURVEY IS PROVIDED PER THE CITY OF TUKWILA BOUNDARY UNE ADJUSTMENT NO. 104 -060, RECORDED UNDER KING COUNTY AUDITOR'S RECORDING N0. 20041008900012, RECORDS OF KING COUNTY. STATE OF WASHINGTON. THIS A.LT.A. SURVEY REFERENCES THE FOLLOWING FOUR POLICIES PROVIDED BY TRANSNATiON TITLE INSURANCE COMPANY: 1) LOAN POUCY OF TITLE INSURANCE, COMMITMENT NO. 800 - 10140309 DATED AUGUST 13, 2003; 2) COMMITMENT FOR ENDORSEMENT, COMMITMENT NO. 800- 10140309 DATED AUGUST 20, 2004; AND 3) PRO -FORMA SPREADING ENDORSEMENT ATTACHED TO LOAN POUCY NO. 10140309 DATED JULY 22, 2004. 4) SECOND COMMITMENT FOR ENDORSEMENT, COMMITMENT .NO.. 800 - 1.0140309.. DATED.DECEMBER,.20, 2004: THE FOLLOWING NOTES (N0. 2 THROUGH 13, INCLUSIVE) PERTAIN TO SPECIAL EXCEPTIONS DISCLOSED IN SCHEDULE "B" OF THE PROVIDED LOAN POUCY DATED AUGUST 13, 2003, OF WHICH THE PROPERTY IS SUBJECT T0, THE FOLLOWING NOTES (N0. 14 THROUGH 18, INCLUSIVE) PERTAIN TO EXCEPTIONS DISCLOSED IN SCHEDULE "B" OF THE PROVIDED PRO -FORMA SPREADING ENDORSEMENT ATTACHED TO LOAN POUCY NO. 10140309 DATED JULY 22, 2004. THE FOLLOWING NOTES (N0. 19 THROUGH 24, INCLUSIVE) PERTAIN TO SPECIAL EXCEPTIONS DISCLOSED iN SCHEDULE "B" OF THE PROVIDED SECOND COMMITMENT FOR ENDORSEMENT DATED DECEMBER 20, 2004., OF WHICH THE PROPERTY IS SUBJECT TO. 2. EXCEPTION PARAGRAPH NOS. 1 1HROUGH 3 "PERTAIN TO GENERAL 1'ROPERTY'TAXES WHICH D0..N0T`PERTAiN TO MATTERS DISCLOSED BY THIS SURVEY: 3. THIS PROPERTY IS SUBJECT TO AN EASEMENT, AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF EXISTING GAS PIPELINES AND SERVICES OVER A VACATED PORTION OF SOUTH 1261)4 STREET. AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FILE NUMBER 8103230520, DATED MARCH 23. 1981. RECORDS OF KING COUNTY WASHINGTON. (EXCEPTION PARAGRAPH N0. 4) 4. THIS PROPERTY IS SUBJECT TO AN EASEMENT, AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF ELECTRIC OVERHEAD AND UNDERGROUND DISTRIBUTION LINE FACILITIES AT DEPTHS NOT EXCEEDING 21 FEET. AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FiLE NUMBER 8111060294, DATED NOVEMBER 6, 1981, RECORDS OF KING COUNTY, WASHINGTON. (EXCEPTION PARAGRAPH NO. 5) 5. THIS PROPERTY IS SUBJECT TO AN AGREEMENT AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF SEWER CONNECTION, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FILE NUMBER 5833297, DATED JANUARY 15, 1985, RECORDS OF KING COUNTY. WASHINGTON. (EXCEPTION PARAGRAPH NO. 6) 6. THIS PROPERTY iS SUBJECT TO AN AGREEMENT AND THE TERMS AND CONDITIONS THEREOF. FOR THE PURPOSE OF SEVER CONTRACT, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FiI.E NUMBER 8909190545, DATED SEPTEMBER 19, 1989, RECORDS OF KiNG COUNTY, WASHINGTON. (EXCEPTION PARAGRAPH NO. 7) 7. THIS PROPERTY IS SUBJECT TO THE RELINQUISHMENT OF ALL EASEMENTS EXISTING. FUTURE OR POTENTIA1, FOR ACCESS, UGHT, VIEW AND AIR, AND ALL RIGHTS OF INGRESS, EGRESS AND REGRESS TO, FROM AND BETWEEN THE LAND AND THE HIGHWAY OR HIGHWAYS TO BE CONSTRUCTED ON LAND CONVEYED BY DEED AS DISCLOSED BY INSTRUMENTS RECORDED UNDER AUDITOR'S FILE NUMBERS 5112409, 5050287, 5092893 AND 5133877, RECORDS OF KING COUNTY, WASHINGTON, ACCESS RIGHTS GRANTED UNDER RECORDING NO. 5112409 WERE AMENDED BY DEED FROM THE STATE OF WASHINGTON RECORDED UNDER KiNG COUNTY RECORDING NO. 8611070566. (EXCEPTION. PARAGRAPH NO. 8) AFN 5112409: THIS DEED CONVEYS AND WARRANTS TO THE STATE OF WASHINGTON A PORTION OF PARCEL "A" AS DESCRIBED WITHIN SAID DEED FOR RIGHT -OF -WAY PURPOSES. IN ADDITION, SAID DEED ALSO CONVEYS AND WARRANTS TO THE STATE OF WASHINGTON AU. RiGHTS OF INGRESS AND EGRESS (INCLUDING ALL EXISTING, FUTURE OR POTENTIAL EASEMENTS OF ACCESS, UGHT, VIEW AND MR) TO, FROM AND BETWEEN THE STATE HIGHWAY AND THE REMAINDER OF SAiD PARCEL "A ". PARCEL "A" As DESCRIBED IN THE DEED HUED UNDER AUDITOR'S FILE NUMBER 5112409, RECORDS OF KING COUNTY WASHINGTON, LIES WITHIN . A PORTION . OF LOTS -7 AND 8 SHOWN ON THIS A.LT.A. SURVEY. NO PROPOSED ACCESS FOR THE FUTURE DEPARTMENT OF HOMELAND SECURITY BUILDING LIES WITHIN SAiD PARCEL "A" OF SAID DEED. AFN 5050287: THIS DEED CONVEYS AND WARRANTS TO THE STATE OF WASHINGTON A PORTION OF PARCEL "A" AS DESCRIBED WITHIN SAID DEED FOR RIGHT -OF -WAY PURPOSES. IN ADDITION, SAiD DEED ALSO CONVEYS AND WARRANTS TO THE STATE OF WASHINGTON ALL RIGHTS OF INGRESS AND EGRESS (INCLUDING ALL EXISTING. FUTURE OR POTENTIAL EASEMENTS OF ACCESS, LIGHT, MEW AND AIR) TO, FROM AND BETWEEN THE STATE HIGHWAY AND THE REMAINDER OF SAID PARCEL "A ". PARCEL "A" AS DESCRIBED IN THE DEED FILED UNDER AUDITOR'S FILE NUMBER 5050287, RECORDS OF 10140 COUNTY WASHINGTON, UES WITHIN A PORTION OF LOT 6 SHOWN ON THIS A.LT.A. SURVEY. NO PROPOSED ACCESS FOR THE FUTURE DEPARTMENT OF HOMELAND SECURITY BUILDING LIES WITHIN SAID PARCEL "A" OF SAID DEED. AFN 5092893: miS DEED CONVEYS AND WARRANTS TO THE STATE OF WASHINGTON A PORTION OF PARCEL "A" AS DESCRIBED WITHIN SAID DEED FOR RIGHT -OF -WAY PURPOSES. IN ADDITION, SAID DEED ALSO CONVEYS AND WARRANTS TO THE STATE OF WASHINGTON ALL RIGHTS OF INGRESS AND EGRESS (INCLUDING AU. EXISTING, FUTURE OR POTENTIAL EASEMENTS OF ACCESS, UGHT, VIEW AND AIR) TO, FROM AND BETWEEN THE STATE HIGHWAY AND THE REMAINDER OF SAID ,PARCEL "A ". PARCEL "A" AS DESCRIBED IN THE DEED FILED UNDER AUDITOR'S FiLE NUMBER 5092893, RECORDS OF KING COUNTY, WASHINGTON, UES WITHIN A PORTION OF LOT 7 SHOWN ON THiS A.L.T.A. SURVEY, THE PROPOSED MAIN ENTRANCE ACCESS FOR THE FUTURE DEPARTMENT OF HOMELAND SECURITY BUILDING LIES WITHIN SAID PARCEL "A" OF SAID DEED. SAID PARCEL 'A" LiES WITHIN THE LIMITED ACCESS AREA TO TUKWILA INTERNATIONAL BLVD. AFN 5133877: THIS DEED CONVEYS AND WARRANTS TO THE STATE OF WASHINGTON A PORTION OF PARCEL "A" AS DESCRIBED WITHIN SAID DEED FOR RIGHT -OF -WAY PURPOSES. IN ADDITION, SAID DEED ALSO CONVEYS AND WARRANTS TO THE STATE OF WASHINGTON ALL RIGHTS OF INGRESS AND EGRESS (INCLUDING ALL EXISTING, FUTURE OR POTENTIAL EASEMENTS OF ACCESS, LIGHT, VIEW AND AIR) TO, FROM AND BETWEEN THE STATE HIGHWAY AND THE REMAINDER OF SAiD PARCEL A. PARCEL "A" AS DESCRIBED IN THE DEED FILED UNDER AUDITOR'S FILE NUMBER 5133877, RECORDS OF KING COUNTY. WASHINGTON, UES WITHIN A PORTION OF LOT 7 SHOWN ON THIS A.L.T.A. SURVEY. NO PROPOSED ACCESS FOR THE FUTURE DEPARTMENT OF HOMELAND SECURITY BUILDING LIES WITHIN SAID PARCEL "A" OF SAID DEED. AFN 8611070586: THIS DEED CONVEYS AND QUITCLAIMS TO THE SABEY ALL RIGHTS OF INGRESS AND EGRESS (INCLUDING ALL EXISTING, FUTURE, OR POTENTIAL EASEMENTS OF ACCESS, LIGHT ViEW, AND AIR) TO, FROM AND BETWEEN THE STATE HiGHWAY LYING SOUTHERLY OF HIGHWAY ENGINEERS' STATION 532 +00 ON THE UNE SURVEY OF THE STATE HIGHWAY, SOUTH 118111 ST. TO JCT. S.S.H. NO. 1 -K AND THE REMAINDER OF PARCEL "A" DESCRIBED WITHIN SAID DEED FILED UNDER AUDITOR'S FILE NUMBER 8611070566, RECORDS OF KING COUNTY. WASHINGTON. PARCEL "A" AS DESCRIBED IN THE DEED FILED UNDER AUDITOR'S FILE NUMBER 8611070566. RECORDS OF KING COUNTY, WASHINGTON, UES WITHIN A PORTION OF LOTS 7 AND 8 SHOWN ON THIS A.LT.A. SURVEY. NO PROPOSED ACCESS FOR THE FUTURE DEPARTMENT OF HOMELAND SECURITY BUILDING LIES WITHIN SAID PARCEL. "A" OF SAID DEED. 8. THIS PROPERTY 15 SUBJECT TO AN AGREEMENT AND 114E TERMS AND CONDITIONS THEREOF. FOR THE PURPOSE OF N0 PROTEST, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FILE NUMBER 8609021068, DATED SEPTEMBER 2, 1986, RECORDS OF KING COUNTY, WASHINGTON. (EXCEPTION PARAGRAPH NO. 9) 9. THiS PROPERTY IS SUBJECT TO AN EASEMENT AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF TELECOMMUNICATIONS FACILITIES, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FILE NUMBER 20001019000148, DATED OCTOBER 19, 2000, RECORDS OF KiNG COUNTY, WASHINGTON. (EXCEPTION PARAGRAPH NO. 10) 10. THIS PROPERTY IS SUBJECT TO AN AGREEMENT AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF FIBER OPTIC CONDUIT AND RECIPROCAL EASEMENT, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FiLE NUMBER 20010809001086, DATED AUGUST 9, 2001, RECORDS OF KING COUNTY, WASHINGTON. (EXCEPTION PARAGRAPH NO. 11, FIBER OPTIC CONDUIT SHOWN HEREON, EASEMENT UNDETERMINED ON THIS SURVEY) 11. - THIS PROPERTY IS SUBJECT TO A DECLARATION OF ACCESS, PARKING AND DRAINAGE EASEMENTS IMPOSED BY INSTRUMENT RECORDED ON MAY 23, 2001 UNDER RECORDING NO. 20030523002434, RECORDS OF KING COUNTY, WASHINGTON. (EXCEPTION PARAGRAPH NO. 12) 12. THIS PROPERTY 15 ABJECT TO AN AGREEMENT AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF DEVELOPER EXTENSION, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FILE NUMBER 20030616000543, DATED JUNE 16, 2003, RECORDS OF KING COUNTY, WASHINGTON. (EXCEPTION PARAGRAPH NO. 13) 13. THIS PROPERTY IS SUBJECT TO AU. COVENANTS. CONDITIONS. RESTRICTIONS, RESERVATIONS, EASEMENTS OR OTHER SERVITUDES, IF AN DISCLOSED BY 01Y OF 'TUKWILA BOUNDARY UNE ADJUSTMENTS RECORDED UNDER KING COUNTY RECORDING NUMBERS 20030327900002 AND 20030725900003. RIGHTS OR BENEFITS, IF ANY, WHICH MAY BE DISCLOSED BY THE RECORDED DOCUMENT(S) ABOVE AFFECTING LAND OUTSIDE THE BOUNDARY DESCRIBED IN SCHEDULE A. (EXCEPTION PARAGRAPH NO. 14) 14. THiS PROPERTY IS SUBJECT TO ALL COVENANTS, CONDITIONS, RESTRICTIONS, RESERVATIONS, EASEMENTS OR OTHER SERVITUDES, IF ANY, DISCLOSED BY THE BOUNDARY LINE ADJUSTMENT RECORDED UNDER RECORDING NO. 20030725900003. THIS POLICY DOES NOT INSURE THAT THE LAND DESCRIBED IN SCHEDULE "A" IS BENEFITED BY EASEMENTS, COVENANTS OR OTHER APPURTENANCES SHOWN ON THE PLAT OR SURVEY TO BENEFIT OR BURDEN REAL PROPERTY OUTSIDE THE BOUNDARIES OF SAID LAND. (PARAGRAPH NO. 1) 15: THIS PROPERTY IS SUBJECT TO A DEVELOPER EXTENSION AGREEMENT AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF A SANITARY SEWER SYSTEM, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S ALE NUMBERS 20010523000481 AND 20010523000482 DATED MAY 23, 2001, RECORDS OF KING COUNTY, WASHINGTON. (PARAGRAPH NO. 2) 16. THIS PROPERTY IS SUBJECT TO AN AGREEMENT AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF PROPERTY OWNER'S ENCROACHMENT INTO CITY RIGHT -OF -WAY, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FILE NUMBER 20010803000205 DATED AUGUST 3, 2001. RECORDS OF KING COUNTY, WASHINGTON. (PARAGRAPH N0. 3) 17. THIS PROPERTY IS SUBJECT TO AN AGREEMENT AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF FIBER OPTiC CONDUIT AND RECIPROCAL EASEMENT, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FILE NUMBER 20010809001066, DATED AUGUST 9, 2001, RECORDS OF KING COUNTY, WASHINGTON. (PARAGRAPH N0. 4, FIBER OPTIC CONDUIT SHOWN HEREON, EASEMENT UNDETERMINED ON THIS SURVEY) 18. MIS PROPERTY IS SUBJECT TO A DEVELOPER EXTENSION AGREEMENT AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF SEWER SERVICE, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FILE NUMBER 20030816000543, DATED JUNE 18, 2003. RECORDS OF KING COUNTY, WASHINGTON. (PARAGRAPH NO. 5) 19. THIS PROPERTY IS SUBJECT TO ALL COVENANTS, CONDITIONS, RESTRICTIONS, RESERVATIONS, EASEMENTS OR OTHER SERVITUDES, iF ANY, DISCLOSED BY THE BOUNDARY UNE ADJUSTMENT RECORDED UNDER RECORDING 140. 20030725900003, RECORDS OF KiNG COUNTY, WASHINGTON. (PARAGRAPH NO. 1) 20. THIS PROPERTY IS SUBJECT TO A DEVELOPER EXTENSION AGREEMENT AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF A SANITARY SEWER SYSTEM, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FILE NUMBERS 20010523000481 AND 20010523000482 DATED MAY 23, 2001, RECORDS OF KING COUNTY, WASHINGTON. (PARAGRAPH NO. 2) 21. TH1S PROPERTY iS SUBJECT TO AN AGREEMENT AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF PROPERTY OWNER'S ENCROACHMENT INTO CiTY RIGHT -OF -WAY, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FILE NUMBER 20010803000205 DATED AUGUST 3, 2001, RECORDS OF KiNG COUNTY, WASHINGTON. (PARAGRAPH NO. 3) 22. THIS PROPERTY IS SUBJECT TO AN AGREEMENT AND THE TERMS -AND •CONDITIONS THEREOF, FOR THE PURPOSE OF FIBER OPTiC CONDUIT AND RECIPROCAL EASEMENT, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FILE NUMBER 20010809001066, DATED AUGUST 9, 2001, RECORDS OF' KING COUNTY, WASHINGTON. (PARAGRAPH NO. 4) 23. THIS PROPERTY IS SUBJECT TO AN AGREEMENT AND THE TERMS AND CONDITIONS THEREOF, FOR THE PURPOSE OF DEVELOPER EXTENSION, AS DISCLOSED BY INSTRUMENT RECORDED UNDER AUDITOR'S FILE NUMBER 20030616000543, DATED JUNE 18, 2003, RECORDS OF KING COUNTY WASHINGTON. (PARAGRAPH NO. 6) 24. PARAGRAPH NO. 8 PERTAINS TO LIABIUTY FOR GENERAL TAXES, SUPPLEMENTAL TAXES, SPECIAL TAXES OR SURFACE WATER MANAGEMENT CHARGES SUBSEQUENT TO THE DATE OF THIS POLICY, TOGETHER WITH ANY INTEREST, PENALTY OR COSTS, AND DOES NOT PERTAIN TO MATTERS DISCLOSED BY THIS SURVEY. SURVEY NOTES 1. LE1CA/WILD TCA 1100 TOTAL STATION USED FOR THIS SURVEY. 2. THIS SURVEY EXCEEDS THE MINIMUM REQUIRED SURVEY PRECISION FOR FIELD TRAVERSES, AS SET FORTH BY WAC 332 - 130 -090. 3. REFERENCE SURVEYS: BOUNDARY LINE ADJUSTMENT, AFN 20041008900012 BOUNDARY LINE ADJUSTMENT, AFN 20030327900003 BOUNDARY LINE ADJUSTMENT, AFN 20001213900008 BOUNDARY UNE ADJUSTMENT. AFN 20000828900001 BOUNDARY UNE ADJUSTMENT, AFN 20010221001777 RECORD OF SURVEY, VOLUME 77 OF SURVEYS. PAGE 209 RECORD OF SURVEY, VOLUME 56 OF SURVEYS. PAGE 43 RECORD OF SURVEY, VOLUME 49 OF SURVEYS, PAGE 127 RECORD OF SURVEY, VOLUME 44 OF SURVEYS, PAGE 204 RECORD OF SURVEY, VOLUME 79 OF SURVEYS, PAGE 63 ALSO, AN UNRECORDED A.LT.A. /A.C.S.M. LAND TITLE SURVEY DONE BY BARGHAUSEN CONSULTING ENGINEERS, INC FOR THE SABEY CORPORATION DATED JANUARY 1999 AND TITLED "BOEING - EAST MARGINAL WAY CORPORATE PARK" 4. THE FLOOD ZONE DESIGNATION FOR THIS PROPERTY IS ZONE "X ", ACCORDING TO THE FEMA FLOOD MAP PANEL NO. 53033C0960F, EFFECTIVE DATE MAY 16, 1995. ZONE "X" IS DESIGNATED AS AREAS DETERMINED TO BE OUTSIDE THE 500 -YEAR FLOODPLAiN. 5. THE CITY OF TUKWILA ZONING DESIGNATION FOR THIS PROPERTY IS AS FOLLOWS: LOTS 6 AND 7 LIE WITHIN THE MIC/H ZONE AND LOT 6 UES WITHIN THE MIC /L, C/U AND LDR ZONES. MIC/H = MANUFACTURING INDUSTRIAL CENTER/ HEAVY INDUSTRIAL MIC/L = MANUFACTURING INDUSTRIAL CENTER/ UGHT INDUSTRIAL CAI = COMMERCIAL/ UGHT INDUSTRIAL LDR = LOW DENSITY RESIDENTIAL THE SETBACKS FOR THE MIC/H ZONE ARE AS FOLLOWS: FRONT - 20 FEET SIDE AND REAR = NONE MAXIMUM BUILDING HEIGHT - 125 FEET NO FLOOR SPACE AREA RESTRICTIONS THE SETBACKS FOR THE MiC/L ZONE ARE AS FOLLOWS: FRONT - 20 FEET SIDE AND REAR - NONE MAXIMUM BUILDING HEIGHT - 4 STORIES OR 45 FEET NO FLOOR SPACE AREA RESTRICTIONS 6. AREA OF LOT 6 - 0.57 AC AREA OF LOT 7 - 5.49 AC AREA OF LOT 8 = 6.91 AC TOTAL AREA OF SITE - 12.97 AC 7. UTILITIES SHOWN HEREON (STORM, SANITARY SEWER AND WATER) ARE TAKEN FROM DESIGN DRAWINGS PROVIDED BY DAVID EVANS AND ASSOCIATES, INC. AND CHS ENGINEERS TO SABEY CORPORATION FOR THE CONSTRUCTION OF THE DEPARTMENT OF HOMELAND SECURITY BUILDING AND PARKING AREA. THE UTILITIES HAVE NOT BEEN FIELD LOCATED NOR VERIfiED TO THE EXTENT Of THEIR HORIZONTAL POSITION OTHER THAN BY VISUAL INSPECTION IN THE FIELD OF FIRE HYDRANTS AND STORM AND SANITARY SEWER STRUCTURE LIDS. REFER TO SAID DESIGN DRAWINGS FOR FURTHER DETAIL OF THESE U1iU11ES. 8. PARKING STALL COUNTS: THERE ARE 378 STANDARD PARKING STALLS. THERE ARE 72 COMPACT PARKING STALLS: THERE ARE 2 VAN HANDICAPPED PARKING STALLS. THERE ARE 8 HANDICAPPED PARKING STALLS. THERE ARE 5 CARPOOL PARKING STALLS. TOTAL. NUMBER OF PARKING STABS 15 463. REVIEVO FOR CODE COMPLIANCE CE APPROVED 20 2012 City of Tukwila BUILDING DIVISION LEGAL DESCRIPTION (PER TRAMSNAiiON TiTLE INSURANCE COMPANY, COMMITMENT NO: 800 - 10140309 DATED .ILLY 21, 2003; LOT 7 LEGAL DESCRIPTION EXCEPTED) PARCEL A: LOT 8, CITY OF TUKWILA BOUNDARY UNE ADJUSTMENT NO. BLA 102 -057, RECORDED UNDER KING COUNTY RECORDING NO. 20030327900002; SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. PARCEL 9: LOT 6. CITY OF TUKWILA BOUNDARY UNE ADJUSTMENT NO. BLA L03 -034, RECORDED UNDER KING COUNTY RECORDING NO. 20030725900003; LOT 7, CITY OF TUKWILA BOUNDARY UNE ADJUSTMENT N0. BLA L04 -060, RECORDED UNDER KING COUNTY RECORDING NO. 20041008900012; SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. PARCEL 0: A NON - EXCLUSIVE EASEMENT FOR CONDUIT FACILITIES AND ACCESS, PARKING AND DRAINAGE AS ESTABUSHED BY AGREEMENTS RECORDED UNDER KING COUNTY RECORDING NUMBERS 20010809001066 AND 20030523002434. SURVEYOR'S CERTIFICATION T0: WASHINGTON CAPITAL JOINT MASTER TRUST MORTGAGE INCOME FUND AND /OR ITS ASSIGNS, TRANSNA1ION TITLE INSURANCE COMPANY AND INTERNATIONAL GATEWAY EAST 10, LLC. THIS IS TO CERTIFY THAT THIS MAP OR PLAT AND THE SURVEY ON WHICH IT IS BASED WERE MADE IN ACCORDANCE WITH THE MINIMUM STANDARD DETALI. REQUIREMENTS FOR A.LT.A. / A.C.S.M. LANO UR � 6 � (8 ED AND •ADOP1ED BY T . .ND .TABLE . IN .1 9 AND IN0. D ITEMS T a � t ()i 14, AND 16 ATHEREOF, (iI) PURSUANT TO THE ACCURACY STANDARDS (AS ADOPTED BY A.L.T.A. AND A.C.S.M. AND IN EFFECT ON THE DATE OF THIS CERTIFICATION), THE POSITIONAL UNCERTAINTIES RESULTING FROM THE SURVEY MEASUREMENTS MADE ON THE SURVEY DO NOT EXCEED THE ALLOWABLE POSITIONAL TOLERANCE; ill THERE ARE NO IMPROVEMENT'S,, ENCROACHMENTS OR USES EXCEPT AS SHOWN AND AS NOTED; (Iv) IMP THE BOUNDARY(S) OF THE PROPERTY(S) FORMS A MATHEMATICALLY CLOSED FIGURE. n. ROBERT C. HERMANN, P.LS. REGISTRATION NO. 18904 IO/^ //-6.200 S GATED blk3oz Tenant: DHS 12500 TUKWILA INTERNATIONAL BLVD. FIRST FLOOR SEATTLE, WA 98168 c GB�Y CORPORATION A Tenant Improvement for: SABEY CORPORATION 12201 TUKWILA INTL BLVD FOURTH FLOOR SEATTLE, WA 98168 -5121 burgess design ( interiors ® architecture 1326 Fifth Avenue . Suite 400 . Sea tie Washington 98101 T: (2061 587.7120 F: (2061 587.7122 All reproduction & intellectual property rights reserved c 2012 Professional seal I'ttU..G1Vl':.J CiTY OF TI)K,",.q! .SEP 1 0 2012 PERMIT CENTER No. Issue Description Date PERMIT SET 09.07.12 Drown by: MK Project No: 1 2.SB04.00 Reviewed by: KK LEGAL DESCRIPTION Originol drowing is 24" x 36 ". Scale entities accordingly if reduced G.0.3 OPEN OFFICE 11' -7" NEW OFFICE OPEN OFFICE CONFERENCE OPEN OFFICE CONSTRUCTION PLAN 0 8' 1 6' 24' 1 /8„ = 1'— On CONTRACTOR TO BUILD ENTIRE PROJECT TO TERMS OF SUPPLEMENTAL LEASE AGREEMENT (SLA) DATED 11.15.11 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 0 2012 City of Tukwila BUILDING DIVISION SYMBOL LEGEND i EXISTING CONSTRUCTION TO REMAIN J■■li•li•* NEW INSULATED NON RATED CONSTRUCTION TO DECK ABOVE, PER DETAIL J /A.9.1 GENERAL CONSTRUCTION NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. 3. ALL INTERIOR PARTITION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PARTITION RATINGS. 4. WHERE PARTITION LAYOUT INTERSECTS EXISTING SHELL /CORE GYPSUM BOARD, REMOVE EXISTING CORNER BEADS AND OTHER ACCESSORIES, ALIGN FACE OF PARTITIONS, TAPE & SAND SMOOTH FOR NEW FINISH. 5. PROVIDE PARTITION ANCHOR BRACKETS FOR ALL CASEWORK, FIXTURES, EQUIPMENT, & DEVICES MOUNTED ON OR ATTACHED TO PARTITIONS. 6. PARTITIONS ARE TO BE BUILDING STANDARD FLOOR TO CEILING PARTITIONS, UON. SEE TYPICAL WALL DETAIL SHEET FOR MORE INFORMATION. 7. DOORS AND CASED OPENINGS WITHOUT DIMENSIONS OR DETAILS ARE TO BE LOCATED 4" FROM ADJACENT WALL OR MATCH EXISTING SUITE STANDARD. 8. ALL WOOD USED IN INTERIOR FRAMING IS TO BE FIRE — RETARDENT TREATED WOOD WHEN BUILDING IS CONSTRUCTION TYPE I AND 11. 9. REFILL ANY ABANDONED CORE DRILL HOLE OR SIMILAR WITH FIRE PROOFING THAT MATCHES THE FLOOR RATING. UON. GENERAL RCP NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEILING PLAN DESIGN. 3. LIGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. 4. UNLESS NOTED OTHERWISE, MULTIPLE SWITCHES IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX AND COVERED WITH A SINGLE COVERPLATE. 5. CLEAN, REPAIR OR REPLACE AS REQUIRED ALL EXISTING SUSPENDED CEILING GRID AND TILES EXISTING TO REMAIN. 6. HVAC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY /RETURN GRILLS PRIOR TO COMPLETION OF PROJECT. 7. ELECTRICAL SUB — CONTRACTOR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES TO BE RELOCATED. 8. PROVIDE EGRESS ILLUMINATION PER IBC 1006. CONTRACTOR IS RESPONSIBLE FOR DESIGN OF THIS SYSTEM UNDER THE DESIGN BUILD CONTRACT. VERIFY WITH BUILDING MANAGEMENT'S EXISTING SYSTEM AND PROVIDE FULL COMPLIANCE TO NEW TENANT SPACE. 9. CUT EXISTING GRID AND SUPPORT AS NEEDED. GENERAL ELECTRICAL NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ELECTRICAL SUB — CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE WORKING CONDITION OF ALL EXISTING OUTLETS NOTED TO REMAIN. 3. 4. 5. ALL OUTLETS SHOWN ARE APPROXIMATE. DUE TO HIDDEN CONDITIONS ADDITIONAL P /P /D MAY EXIST BUT NOT BE REFLECTED ON THE PLANS. FURNITURE SHOWN FOR INTENT ONLY, FINAL LOCATION OF FURNITURE AND OUTLETS TO BE COORDINATED WITH TENANTS FURNITURE VENDOR. VERIFY ELECTRICAL AND VOICE /DATA REQUIREMENTS WITH TENANT. UNLESS DIRECTED OTHERWISE, ALL VOICE /DATA CABLING AND EQUIPMENT ASSOCIATED WITH VOICE /DATA SERVICE INCLUDING WORK FROM BUILDING /FLOOR D —MARK TO SERVER ROOM SHALL BE FURNISHED AND INSTALLED BY TENANT. GENERAL FINISH NOTES 1. VERIFY ALL FINISHES WITH G.C. AND TENANT. KEYED SHEET NOTES PATCH AND REPAIR ALL EXISTING FINISHES AS REQUIRED AFTER CONSTRUCTION TO MAINTAIN SUITE STANDARD. 2O EXISTING LIGHTING TO BE ADJUSTED AS REQUIRED AFTER CONSTRUCTION TO MAINTAIN EXISTING LIGHTING LEVELS. ANY LIGHTING RELOCATION TO BE COORDINATED WITH TENANT. O3 PROVIDE MINIMUM OF (3) THREE ELECTRICAL OUTLETS PER OFFICE AND (2) TWO DATA OUTLETS PER OFFICE AND (1) ONE VOICE OUTLET PER OFFICE. ALL ELECTRICAL AND VOICE /DATA OUTLETS LOCATIONS TO BE DETERMINED AND COORDINATED WITH TENANT. ALL NEW FINISHES TO BY COORDINATED WITH AND DETERMINED BY TENANT. CONTRACTOR TO VERIFY DIMENSIONS ON SLA AGAINST MULLION SPACING AND DETERMINE WITH TENANT ACTUAL LAYOUT OF OFFICES. SLA HAS 5' -6d" DIMENSION FROM EXISTING FURNITURE PANEL TO NEW PARTITION AS SHOWN. VERIFY TRUE LAYOUT WITH TENANT IF DISCREPANCY. WE PROVIDED 13' -8" DIMENSION FOR REFERENCE. D Tenant: DHS 12500 TUKWILA INTERNATIONAL BLVD. FIRST FLOOR SEATTLE, WA 98168 A Tenant Improvement for: SABEY CORPORATION 12201 TUKWILA INT'L BLVD FOURTH FLOOR SEATTLE, WA 98168 -5121 • •' burgess design I interiors 0 architecture 1326 fifth Avenue . Suite 400 . Seat le Washington 99101 T: (2061 S97.1120 F: (200 587,71n All reproduction & intellectual property rights reserved c 2012 Professional seal Ktkitty so n :1TY OF TU,.1 nt ^ SEP 1 0 2012 PERMIT CENTER No. Issue Description Date PERMIT SET 09.07.12 Drawn by: MK Project No: 12.SB04.00 Reviewed by: KK CONSTRUCTION PLAN Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.2A.1 " DEVICES SHOWN STACKED IN PLAN ARE TO ALIGN VERT. AS SHOWN BELOW AT LOCATION AS DIMENSIONED ON PLAN; OR NEXT TO DOOR / OPENING AS DIMENSIONED BELOW FIRE ALARM STROBE FRAME WHERE OCCURS ROOM SIGNAGE, ETC. THERMOSTAT LIGHT & PROJECTION SCREEN SWITCHES, WALL MOUNTED OCCUPANCY SENSOR CARD READER WHERE OCCURS HARDWARE LATCH TELEPHONE OUTLET FINISHED FLOOR ELECTRICAL OUTLET 1. LOCATE SWITCHPIATES, ELECTRICAL AND TELEPHONE WALL OUTLETS AT NEAREST STUD FROM SCALED LOCATION ON PLAN, UNLESS SPECIFICALLY DIMENSIONED ON PLAN, ELEVATION, OR LOCATION AS PER DIAGRAM ABOVE. 2. CENTER FIRE ALARM STROBES DIRECTLY ABOVE FIRE EXTINGUISHER CABINETS WHERE BOTH OCCUR. 3. DETAIL IS SCHEMATIC IN NATURE AND ADA COMPLIANCE MAY BE ACHIEVED WITHIN A RANGE. VERIFY WITH ARCHITECT IF QUESTIONS. 4. IN AREAS WHERE ACCESS FLOOR HAS BEEN REMOVED; VERIFY WITH BUILDING MANAGEMENT AND TENANT WHETHER DEVICES SHOULD BE ALTERED TO STANDARD HEIGHTS. UGHT SWITCHES MUST BE LOWERED TO ADA COMPLIANT HEIGHTS. A GENERAL DEVICE ALIGNMENT 1/4" NTS BOTTOM OF STRUCTURE ACOUSTIC SEALANT ATTACH GWB TO METAL STUDS LONG LEG TOP TRACK POWDER DRIVEN FASTENER 24 "oc CEILING AS SCHEDULED 3 5/8" X 20 GA. (33 MILS) METAL STUDS STUDS 24" OC, TO 14' -9" MAX. HEIGHT STUD SPECIFICATION SHOWN IS ONE SOLUTION. SINCE CEILING IS INTACT CONTRACTOR COULD NARROW STUD GAUGE & WIDTH AND BRACE ACCORDINGLY AS LONG AS ACOUSTIC INTEGRITY IS MAINTAINED 1 LAYER OF 5/8" TYPE "X" GYP. BD. EA. SIDE OF METAL STUDS ATTACHED W/ 16 SCREWS 0 12" O.C. MAX. INSULATION UON ON PLANS POWDER DRIVEN FASTENER 24 "oc MET RUNNER TRACK ACOUSTIC SEALANT CONCRETE SLAB NON -RATED FLOOR TO DECK PARTITION 0" 4" 8" 12" 3" = 1' -0" DOOR & HARDWARE GENERAL NOTES 1. SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION. 2. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME 0 HEAD. REFER TO SPECIFICATIONS FOR CLEARANCES. 3. DOUBLE DOOR NOMINAL WIDTH INDICATES 2 DOOR LEAVES OF EQUAL WIDTH, U.O.N. 4. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH — BOLTS. 5. DOOR / HARDWARE SHALL COMPLY WITH ALL APPUCABLE IBC & ACCESSIBILITY REQUIREMENTS. DOOR SCHEDULE w CO 8 DOOR NOMINAL WIDTH NOMINAL HEIGHT HARDWARE GROUP 101 3' -0" 102 3' -0" MATCH EIS EXIST A 1 HM N/A A HM N/A HARDWARE GROUP HARDWARE GROUP HARDWARE REMARKS GROUP 1 SINGLE, OFFICE LOCKSET NON —RATED 1 OFFICE FUNCTION LOCKSET 3 HINGES 1 WALL — MOUNTED DOOR STOP DOOR TYPES -- BUILDING STANDARD HOLLOW METAL FRAME PAINTED TO MATCH SUITE STANDARD 1 WIDTH FLUSH S.C. WOOD DOOR FINISH TO MATCH SUITE STANDARD REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 0 2012 City of Tukwila BUILDING DIVISION Tenant: DHS 12500 TUKWILA INTERNATIONAL BLVD. FIRST FLOOR SEATTLE, WA 98168 4 AIL D R P H ATtON A Tenant Improvement for: SABEY CORPORATION 12201 TUKWILA INT'L BLVD FOURTH FLOOR SEATTLE, WA 98168 -5121 burgess design J interiors Q architecture 1326 Fifth Avenue. Suite 400 Seattle Washington 98101 T;(206)937.1120 F: (206) S87.7122 All reproduction & intellectual property rights reserved c 2012 Professional seal REuto,w CITY OF TUKi "I. SEP 10 2012 PERMIT CENTER No. Issue Description Dote PERMIT SET 09.07.12 Drawn by: MK Project No: 12.SB04.00 Reviewed by: KK DOOR SCHEDULE / DETAILS Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.9.1