HomeMy WebLinkAboutPermit D12-305 - GRAINGER WW - STORAGE RACKS AND EMERGENCY LIGHTINGGRAINGER W W INC 6725 TODD BL D12 -305 Parcel No.: Address: Suite No: Project Name: City oftI'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov 7888900060 672S TODD BL TUKW GRAINGER W W INC DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: D12 -305 01/31/2013 07/30/2013 Owner: Name: Address: GRAINGER W W INC C/O MARVIN F POER & CO , 18818 TELLER AVE STE 277 92612 Contact Person: Name: DAN O'REILLY Address: 2500 YORK RD , ELK GROVE VILLAGE IL 60007 Contractor: Name: WYNRIGHT CORPORATION Address: 2500 YORK RD , ELK GROVE VILLAGE IL 60007 Contractor License No: WYNRIC *907P9 Lender: Name: GRAINGER Address: 100 GRAINGER PY , LAKE FOREST IL 60045 Phone: 847 766 -3212 Phone: 847- 595 -9400 Expiration Date: 10/29/2014 DESCRIPTION OF WORK: THE WORK TO BE PERFORMED WILL CONSIST OF THE DISMANTLE OF EXISTING DAMAGED STORAGE RACK IN AREAS DESIGNATED AS PHASES I, II, AND III. THE STORAGE RACK IN THESE AREAS WILL BE REPLACED WITH NEW COMPONENTS. ALONG WITH COMPONENT REPLACEMENT A NUMBER OF THE STORAGE LEVELS WILL BE RECONFIGURED AS SHOWN ON THE PLANS (MSDS SHEETS PROVIDED ON CD). UPGRADE OF GENERAL EMERGENCY LIGHTING AND EXIT LIGHTING TO BE INCLUDED. Value of Construction: $40,000.00 Type of Fire Protection: SPRINKLERS /AFA Type of Construction: Electrical Service Provided by: PUGET SOUND ENERGY Fees Collected: International Building Code Edition: Occupancy per IBC: $3,206.57 2009 0024 * *continued on next page ** doc: IBC -7/10 D12 -305 Printed: 01 -31 -2013 Public Works Activities: Charmelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: �. Date: Q`?7I`I2) 1 hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. governing this work will be complie The granting o construction o to this pe t. Signature: ermit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating rformance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached Date: // 37 lg Print Name: ST/s015)-0 u 0-4 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. doc: IBC -7/10 D12-305 Printed: 01 -31 -2013 13: All construction shall be done in conform with the approved plans and the requirem -of the International Building Code or International Residential International Mechanical Code, Washingt to Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 1.2: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDFFIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: Clearance between ignition sources, such as light fixtures, heaters and flame- producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 16: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinlder at the 15 foot elevation of the column, (c) ceiling sprinlder density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 17: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 18: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 19: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2328) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 21: Sprinlders shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 22: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer Incensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance No. 2327). 23: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot -candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) doc: IBC -7/10 D12-305 Printed: 01 -31 -2013 24: Exits and exit access doors shall be mar by an approved exit sign readily visible fro any direction of egress travel. Access to exits shall be marked by r y visible exit signs in cases where the exit path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no t in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 25: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 26: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 27: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 28: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 29: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 30: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 31: Maintain fire extinguisher coverage throughout. 32: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -305 Printed: 01 -31 -2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No.` Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: King Co Assessor's Tax No.: 6725 South Todd Blvd. Tukwila, WA 96188 Suite Number: Floor: Tenant Name: Grainger PROPERTY OWNER Name: Dan O'Reilly or (Steve Gucwa 847 - 766 -3274) Name: Grainger City: Elk Grove Village State: IL Zip: 60007 Address: 100 Grainger Parkway Zip: 60007 City: Lake Forest State: IL Zip: 60045 CONTACT PERSON — person receiving all project communication Name: Dan O'Reilly or (Steve Gucwa 847 - 766 -3274) Address: 2500 York Rd. City: Elk Grove Village State: IL Zip: 60007 City: Elk Grove Village State: IL Zip: 60007 Phone: (847) 766 -3212 Fax: (847) 595 -2126 Email: doreilly @wynright.com Address: GENERAL CONTRACTOR INFORMATION Company Name: Wyntakright Corp. Address: 2500 York Road City: Elk Grove Village State: IL Zip: 60007 Phone: (847) 595 -9400 Fax: (847) 595 -2126 Contr Reg No.: WYNRIC907 -P Exp Date: Tukwila Business License No.: II: \Applications \ Forms - Applications- On Line \20I 1 Applications \Permit Application Revised - 1 -9 -11 docx Revised: August 2011 bh New Tenant: ❑ Yes ® .. No ARCHITECT OF RECORD Company Name: Structural Concepts Engineering Engineer Name: Ali Abolhassani Company Name: N/A City: Anaheim State: CA Zip: 92807 Phone: (714) 632 -7330 Fax: (714) 632 -7763 Architect Name: N/A Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Structural Concepts Engineering Engineer Name: Ali Abolhassani Address: 1200 N. Jefferson St. Suite F City: Anaheim State: CA Zip: 92807 Phone: (714) 632 -7330 Fax: (714) 632 -7763 Email: mail @sceinc.net LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Grainger Address: 100 Grainger Parkway City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATIO. - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 66,101 Existing Building Valuation: $ 7,500,000 Describe the scope of work (please provide detailed information): The work to be performed will consist of the dismantle of existing damaged storage rack in areas designated as Phases I, II, and III. The storage rack in these areas will be replaced with new components. Along with component replacement a number of the storage levels will be reconfigured as shown on the permit approval plans provided. Will there be new rack storage? ® Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: • Sprinklers ▪ Automatic Fire Alarm ❑ None ❑ Other pecify) Will there be storage or use of flammable, combustible or hazardous materials in the building? Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. I1:\ Applications \Forms- Applications On Line \201 1 Applications \permit Application Revised - 1- 9.11.docx Revised: August 2011 bh Page 2 of4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 " Floor 57,300 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: • Sprinklers ▪ Automatic Fire Alarm ❑ None ❑ Other pecify) Will there be storage or use of flammable, combustible or hazardous materials in the building? Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. I1:\ Applications \Forms- Applications On Line \201 1 Applications \permit Application Revised - 1- 9.11.docx Revised: August 2011 bh Page 2 of4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 09/14/2012 Print Name: Darrell Luff Day Telephone: (425) 738 -6121 Mailing Address: 6725 Todd Boulevard Tukwila WA 96188 II:AAppGeations\Fonns- Applications On LineA201 1 ApplicationsV Permit Application Revised - R -9 -1 Ldocx Revised: August 201 I bh City State Zip Page 4 of 4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7888900060 Address: 6725 TODD BL TUKW Suite No: Applicant: GRAINGER W W INC RECEIPT Permit Number: 1)12-305 Status: APPROVED Applied Date: 09/17/2012 Issue Date: Receipt No.: R13 -00673 Payment Amount: $2,470.44 Initials: JEM Payment Date: 01/31/2013 12:14 PM User ID: 1165 Balance: $0.00 Payee: WYNRIGHT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2058782 2,470.44 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $2,470.44 1,940.65 525.29 4.50 ,doc: Receipt-06 Printed: 01 -31 -2013 • Ill CCity of Tukwila 08- Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7888900060 Address: 6725 TODD BL TUKW Suite No: Applicant: GRAINGER W W INC RECEIPT Permit Number: D12-305 Status: PENDING Applied Date: 09/17/2012 Issue Date: Receipt No.: R12 -02627 Initials: User ID: TLS 1670 Payment Amount: $736.13 Payment Date: 09/17/2012 03:30 PM Balance: $1,137.00 Payee: WYNRIGHT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2055744 736.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 736.13 Total: $736.13 doc: Receipt -06 Printed: 09 -17 -2012 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7888900060 Address: 6725 TODD BL TUKW Suite No: Applicant: GRAINGER W W INC RECEIPT Permit Number: D12-305 Status: ISSUED Applied Date: 09/17/2012 Issue Date: 01/31/2013 Receipt No.: R13 -01764 Payment Amount: $378.00 Initials: WER Payment Date: 05/31/2013 11:30 AM User ID: 1655 Balance: $0.00 Payee: WYNRIGHT INTRALOGISTICS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 206 -1226 378.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING INVESTIGATION 000.322.800 378.00 Total: $378.00 doc: Receipt -06 Printed: 05 -31 -2013 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 I- (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 D/2 -5O5 Project: 6i ?AiM6.FP Type of Inspection: ' /� �ri�FQ rc� Lf N Address: , , 725 T5A) 01/i) Date Called: 3l /t , L /,urn` Zf /7,-r 11/ rT j c) Pd51^4 ),' - /ipp /�°f! Special Instructions: c: 30 S7FVAA/ -- .212,4"L 1 9' Cr -- Date Vented: (��,, ,, / 3 �� C J' p.m. Requester: (L/7- zat,- 5-82 0 Phone No: Z/25 - ).3 6. - 6 /?_ / pproved per applicable codes. El Corrections required prior to approval. a COMMENTS: 0 F/24/4/ A/4— 4 eP' l) fn 1fe ,F-A/ e/ - L%GH 72- &I-6 — 40io/ct/iC 3l /t , L /,urn` Zf /7,-r 11/ rT j c) Pd51^4 ),' - /ipp /�°f! ,. ,; ,?,)fi'S i4pP,r ^o✓G6 rn ),'% (/ Id 1i0 k /P /r iilh9 % s`pec�6f' 6,4_ Date: l4-- / 3 R INSPECTION FE REQUIRED. Prior to next inspection. fee must be R at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit L 12 - 3 05 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 �- Project: CI, RAirsi (oFe Typ f Inspections Tr A- M. (4 e. Address: 1��25 77)b6 8 D to Called: , 2- - i----- r riwOut-7 Special Instructions: Date Wanted:. a.m Requester: Phone No: ..- ge'i-43 0 -5 Approved per applicable codes. Corrections required prior to approval. COMMENTS: p /1+ ,, A k3NAAse '1....- 4? 2- - i----- r riwOut-7 PLAM'cl i Inn :tor: pa eA FEE REQUIRED. P for to next in ection. fee' must be. uthcenter Blvd., Su. 100. Call t^sched'ule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 12.-3 0.5- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: Crat e.J. Sprinklers: Type f Inspection: c P J Address: -Suite #: c %2S' 10471 ,p l / blye/ Contact Person: Special Instructions: % Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: IC f 4_ ri n of/ % /'Or c K i n c la m M3/'] hat(10.6 D� DU / ere*, e*, c/ e..4C /1-6" 4/175 ill a O v( y F "1-7-f"' o.-, Needs Shift Inspection: " Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspectors' Fp/ !"'1( Date: apih -R Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • ., INSPECTION NUMBER • INSPECTION R CORD Retain a copy with V ermit r_ rr D/0 - 3o5 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: Sprinklers: Typ of I pection: Address: 673. Suite #: To t. b S Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: knD CI it. ei.1--/V ?cif Sk1/ m' /144;0 fA'fav 6v -o!ac7-P Hood & Duct: AL— S--\-. I► iJipad.ej Pre -Fire: OK' 1n S . Occupancy Type: a. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: A s- a— Date: /7//� Hrs.: l _ r. $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.Q. Form F.P. 113 i; L /THGN /A L/GHT /NG' FEATURES & SPECIFICATIONS INTENDED USE Cc bbi ationemergmgOpiningwetandedtSuitablefmElmninatfngUlepathofegressand (emoting the means of ages in=damn with life Safety Code NFPA 101. CONSTRUCTION Injeclkermoided, Ramem tardath ;NBfeLmpagthermoplastichoudngwit snap-ill design mmponems foteasyImtallaton ikdvena11- Eoapaltem.Uni emalchermnsameasiyr moeedfordirectlonaihdladon. Fiy assembled single face with 82a faceplate (creasy Reld-convaslon to ddr6le face Dart and Mod magmas permits full range of lamp adprsmmeht Law 100ftviewing distance ramp, based on UL924standards. °VACS The typlal ilk ofdee LED lamp Is10yearstwol BW1EDla mps for emergency light. ELECTRICAL Dud-wlagehhput120Ta27riAC;9 6YomtpmLEmergenrymnmboprovidedwIdgestneildutatmsIndka- wandrechagohkbarber y.Malnteance- (rtenickeka nimhbatteryprovides90nOnutesmfemmegemry Ammer. High output 010) opton powers up to 2 LED remote lamps. LISTINGS 111 listed. Meets U1924, NFPA 101, NFiA 70- NEC and 051U illumination standaNs I docedamploation 327 to 122E (0• to WV listed standarl WARRANTY Nxhue are osmed 18lllhonla lighting 24ltmmhwarranty against aadhadal defects Inmanufacture. All life sealant/potent indudngemergencyEghtngforpatm(( egressmlastbemaintain ed,stivked,and testedlaa® tdamewdmhall ItreandFirelt( tedionAswdate0IFRVand Mod codes FaOmemp prison the maggenance, sante, ortesdn9muldpsmpasda Muddy of(o tteandwNvddaEwstantes Notes Spedhmtmu subject to du gas wmwutnmhe. Actual performance may differ as a insult of endvser eMlceanent and aerUatas ORfiRIf7GINf ORMATION ;G , REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 4 2013 City of Tukwila ING DIVISION Contractor Select LED Exit/Unit Combos eomeoslomnemdwtereanmml rdancs(asnobpi. —.] Feb IFD A16 7&231874592 Gteem 129)277 32 106 6 EIAWG3 %tre an, Lbadunoimt anlyr ELALEDIA12 Single remote lame E A LED TMI2 Double remote laiopu EU IOW MI2 Single, weather-pad remote lampcs EIA LED TWPMill Double. weather-proof remote Mau Notes I Seespec sheet 11831s Icogaske 3 OabsratedewbbIDoptlm CONTRACTOR SELECT / EMERGENCY CORRECTION s LED - EXIT -UNR- COMBOS RECEIVED CITY OF TUKWILA NOV 0 9 2012 PERMIT CENTER r IOTA ENGINEERING PRODUCT SPECIFICATION SHEET 1-162 PARALLEL OPERATION EMERGENCY BALLAST 14l3ci• 11 11io7 �" The 1 -162 from IOTA Engineering is a UL Listed fluorescent emergency ballast that allows the same fixture to be used for both normal and emergency operation. in the event of a power failure, the 1-162 switches to the emergency mode and operates Iwo of the existing lamps In parallel for 90 minutes. The unit contains a battery, charger, and inverter dreuti in a single can and Is provided with 2 feet of 3/8" flex for wiring to the fixture. The unit Is designed for installation neat to or on top of the fbdure. The 1-162 can be used with most 2'-4' T8 and 112 linear lamps, 54W19, or 26W-57W 4-pin compact lamps, with an initial output of up to 3000 lumens for two Tamps. The 1-162 is compatible with all electronic or magnetic, series or parallel output, multi-famp ballasts. The 1-162 Is suitable for use in damp Iocatlons. Input Voltage (Dual) 120/277V, 80Hz Input Wattage 4.5 Watts Lamps Operated Most 2'-4' single, bipin T8 & 112 HO or VHO fluorescent lamps, 54W T5 and 28W-57W 4-Pin compact lamps Emergency Operation (2) 2'-4' T8 and T12, (2) 54W T5 Linear Lamps or (2) 28W -57W 4-pin Compacts - 90 minutes Initial Illumination" (2) lamps 3000 lumens (1500 lumens each lamp) Operating Temp 00 to 50° C Battery 24 Hour Recharge 7 -10 Year Life Expectancy Weight 9.75 lbs. Approval UL and CUL Listed c US "Initial lamination Is 2000 lumens when one tamp Is Inoperable 18.375" x 3.0' x 3.0 (mounting center 15.875") LENGTH 15375' .4— MOUNTING CENTEA 15.376 —,; IOTA REV 001312 0 WIDTH 3.3` IHEIGHT 3P MODEL NO: TYPE. PROJECT: COMMENTS: LAMPS OPERATED' Most 2'-4' single, blpin,T8 &T12, NO or VHO dual:scentlamps, 54W T5, and 26W -57W 4-Pin compact lamps "RsSwIe Lwnen Rawson ChM DRUM or mmpa9He romps PRODUCT ADVANTAGES 3000 Lumen Output Parallel Lamp Operation Time Delay feature for compatibility with End-of-Lamp-Life circuitry Open Clrnrk Isolation protects unit when load Is absent FEATURES Will cold start and operate all specified lamps Long life high temperature recyclable NI-Cad battery Painted steel case Includes test switch and charge indicator accessory Idt For use with switched or unswftched fixtures 5-Year Warranty. See Warranty Page for details. Suitable for use in damp locations Meets or exceeds all National Electrical Code and Ufe Safety Code Emergency Ughting Requirements International Voltage models available ENGINEERING 00.80X 11948 TUCSON, AZ ISM (510) 294 -3292 • FAX (528)7414897 aww.IotsengleeerIng.eom 1 -162 PARALLEL oven am ELIEMENCY BALLAST CONFIGURATION NI TWO -PIECE TEST SWITCH AND CHARGE INDICATOR ACCESSORIES ❑ RTK - REMOTE TEST KIT (MAY BE REQUIRED FOR DOWNUGHT OR OTHER APPUCATIONS) SPECIALTY ❑ I -162R (RECESSED PANEL) VOLTAGE RATINGS • 120/277V 8OHZ (STANDARD) ❑ 220V 50HZ ❑ 240V 60HZ ❑ 120V 50HZ LAMP 2 LAMPS F28 T8 2700 F32 T8 3000 F40 T12 2675 54W T5 2500 26W PL CF QUAD 4 -PIN 2600 32W PL CF QUAD 4 -PIN 2750 42W PL CF QUAD 4 -PIN 2800 57W PL CF QUAD 4 -PIN 2500 REMOTE MOUNTING When battery packs are remote mounted. consult Customer Service for the ma)dmum allowable distance between the battery pact and lamp(s). IOTA REV 091312 1-162 SAMPLE SPECIFICATION Emergency lighting shall be provided by using a standard fluorescent fix- ture equipped with an IOTA 1-162 fluorescent emergency battery pack. The 1-162 shall consist of a high temperature, maintenance -free nickel cadmium battery, charger board and an electronic circuit enclosed In a 16.375" x 3.0" x 3.0` vandal - resistant painted steel ease for Installation either adjacent to or on top of the fbdure. A long -life LED charge Indicator light and test switch shall be Included. The fluorescent EM pack shall operate two 20W -40W (2'-41 78 - T12 fluorescent lamps, two 54W T5 fluorescent lamps, or two 26W- 57W 4-pin compact fluorescent lamps, in PARALLEL OPERATION. The 1-162 shall provide reduced illumination for a minimum of 90 minutes in the emergency mode wllh a total initial output of 3000 lumens. Should one lamp become Inoper- able, the remaining lamp shall operate at a minimum initial output of 2000lumens. The 1-182 shall have 4.5 watts of Input power and a battery capacity of 57.6 watt hours.The 1 -162 Is UL Usted and meets or exceeds all NEC and Life Safety Code Emergency Lighting Requirements, and is rated for use in damp locations. The 1-162 Is warranted fora Lull five (5) years from the date of purchase. PARALLEL LAMP SAMPLE SPECIFICATION Emergency lighting shall be provided by using a standard fluorescent fixture equipped with a fluorescent emergency battery pack. The EM pack shall consist of a high temperature, maI denance -free nickel cadmium battery, Charger board and an electronic circuit enclosed In a painted steel case for Installation either adjacent to or an top of the fixture. A long-life LED charge Indicator fight and test swttch shall be included. The fluorescent EM pack shall operate two 20W -40W (2•41 T8 - 712 fluorescent lamps, two 54W 75 fluorescent lamps, or two 26W-57W 4-pin compactfluorescent lamps In PARALLEL OPERATION. The EM pack shall provldareduced Illumination fora minimum of 00 minutes In the emergency mode with a total initial output x13000 lumens. Should one lamp become Inoperable, the remaining lamp shall operate at aminimum initial output of 2000Iumena.The unl shall have 4.5 watts of Input power end a battery capacity of 57.8 watt hours. The EM pack must be UL Usted and meet or exceed all NEC and Llfe Safety Code Emergency Lighting Requirements, and rated for use in damp locations. AO product shall be warranted for a full five (5) years from the date of purchase. <IOTA CNOINECRINO PO SOX 1 1046 TUCSON, AZ 88754 TEL' 1- 8004368 •40TA 14852) FAX MOM 741-2537 WC81 wwwJOTACN IMCCiuW3.00M Stj ctural L.#oncepts ngineering P' FILES ®� Pei *�,► Y Project Name : GRAINGER Project Number : M- 080212 -7 Date : 08/16/12 Street Address : 6725 SOUTH TODD BLVD City /State : TUKWILA, WA 98188 Scope of Work : SELECTIVE RACK 1200 N. Jefferson St, Suite F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 e -mail: mail @sceinc.net REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 4 2013 City of Tukwila BUILDING DIVISIO CITYRSVaitA SEP 112012 PERMIT CENTER n EXPIRES 1L n.. n„ AUG 1 6 2012 pJV3O5 Str ctural oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: GRAINGER Project #: M -080212 -7 TABLE OF CONTENTS Title Page 1 Table of Contents 2 Design Data and Definition of Components 3 Critical Configuration 4 Seismic Loads 5 to 6 Column 7 Beam and Connector 8 to 9 Bracing 10 Anchors 11 Base Plate 12 Slab on Grade 13 Other Configurations 14 to 15 GRAINGER -M -08021 2 -7 -TYPE 16U2O SELECTIVE RACK Page of j S 8/16/2012 Str ctural kiooncepts Enguneering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Design Data Project: GRAINGER Project #: M -080212 -7 1) The analyses conforms to the requirements of the 2009 IBC and the 2008 RMI /ANSI MH 16.1 Rack Design Manual Steel Storage Racks (RMI) and the ASCE 7 -05, section 15.5.3 2) Transverse braced frame steel conforms to ASTM A570, Gr.55, with minimum strength, Fy =55 ksi Longitudinal frame beam and connector steel conforms to ASTM A570, Gr.55, with minimum yield, Fy =55 ksi All other steel conforms to ASTM A36, Gr. 36 with minimum yield, Fy= 36 ksi 3) Anchor bolts shall be provided by installer per ICC reference on plans and calculations herein. 4) All welds shall conform to AWS procedures, utilizing E70xoc electrodes or similar. All such welds shall be performed in shop, with no field welding allowed other than those supervised by a licensed deputy inspector. 5) The slab on grade is 5" thick with minimum 2500 psi compressive strength. Soil bearing capacity is 1000 psf. Definition of Components Frame Height l Beam A Product Beam Spacing Beam Length Front View: Down Aisle (Longitudinal) Frame Column Beam to Column Connector Base Plate and Anchors Panel Height 1.4. Frame td Depth Section A: Cross Aisle (Transverse) Frame Horizontal Brace Diagonal Brace GRAINGER -M -0802 12 -7 -TYPE I GU2O SELECTIVE RACK Page of of 1 8/IG/2Of2 Structural Concepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By. S. P. Project GRAINGER Project S M -080212 -7 Configuration & Summary: TYPE 16U20 SELECTIVE RACK 192' 18" 18' 48" 42' 42' 7 36' **RACK COLUMN REACTIONS ASO LOADS AXIAL DL= 4001b AXIAL LL= 4,8001b SEISMICAXIAL Ps =+ /- 3,258 Ib BASE MOMENT= 0 in -lb Seismic Criteria # Bm Lvls Frame Depth Frame Height 40" —1,— 24" Beam Length Frame Type Ss= 1.383, Fa =1 8 24° 'l- 192.0 in 5 24° Single Row Fy =55 ksi 192" _i— Capacity: 1895 Ib /pr 0.63 -0K Beam Connector 24" Lvl 2: 2 pin OK I Mconn =2271 in -Ib Mcap =12970 in -Ib 0.18 -0K 2a° Fy =55 ksi 2- 1 /4'x1'x16ga 0.41 -0K 24" Fy =55 ksi 2 -1 /4'x1 "xl6ga 0.76 -0K -k Fy =36 ksi 7 in x 5 in x 0.375 in I Fixity 0 in -Ib 0.7 -0K 8' 2 per Base 0.5" x 3.25" Embed HILTI KWIKBOLT 17 ESR 1917 Inspection Reqd (Net Seismic Uplift =1924 Ib) 0.65 - OK * 5" thk x 2500 psi slab on grade. 1000 psf Soil Bearing Pressure 0.84 -0K Level Load Per Level I Brace Story Force Transv - Column Axial 144 192' 18" 18' 48" 42' 42' 7 36' **RACK COLUMN REACTIONS ASO LOADS AXIAL DL= 4001b AXIAL LL= 4,8001b SEISMICAXIAL Ps =+ /- 3,258 Ib BASE MOMENT= 0 in -lb Seismic Criteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss= 1.383, Fa =1 8 36 in 192.0 in 5 144 in Single Row Component Description STRESS Column Fy =55 ksi UnarcoT01 25 3x1.625x12ga P =4550 Ib, M =2303 in -Ib 0.4-OK Column & Backer None None None N/A Beam Fy =55 ksi Unarco 4356 3.56 "xl4ga Lu =144 in Capacity: 1895 Ib /pr 0.63 -0K Beam Connector Fy =55 ksi Lvl 2: 2 pin OK I Mconn =2271 in -Ib Mcap =12970 in -Ib 0.18 -0K Brace - Horizontal Fy =55 ksi 2- 1 /4'x1'x16ga 0.41 -0K Brace - Diagonal Fy =55 ksi 2 -1 /4'x1 "xl6ga 0.76 -0K Base Plate Fy =36 ksi 7 in x 5 in x 0.375 in I Fixity 0 in -Ib 0.7 -0K Anchor 2 per Base 0.5" x 3.25" Embed HILTI KWIKBOLT 17 ESR 1917 Inspection Reqd (Net Seismic Uplift =1924 Ib) 0.65 - OK Slab & Soil 5" thk x 2500 psi slab on grade. 1000 psf Soil Bearing Pressure 0.84 -0K Level Load Per Level Beam Spcg Brace Story Force Transv Story Force Longit. Column Axial Column Moment Conn. Moment Beam Connector 1 1,200 Ib 8.0 in 42.0 in 12 Ib 4 Ib 5,200 Ib 970 "# 1,808 "# 2 pin OK 2 3 4 5 6 7 8 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib 24.0 in 24.0 in 24.0 in 24.0 in 24.0 in 24.0 in 40.0 in 42.0 in 48.0 in 18.0 in 18.0 in 48 Ib 83 Ib 119 Ib 155 Ib 190 Ib 226 Ib 285 Ib 17 Ib 29 Ib 41 Ib 54 Ib 66 Ib 78 Ib 99 Ib 4,550 Ib 3,900 Ib 3,250 Ib 2,600 Ib 1,950 Ib 1,300 Ib 650 Ib 2,303 "# 2,204 "# 2,031 "# 1,783 "# 1,461 "# 1,065 "# 991 "# 2,271 "# 2,169 "# 2,011 "# 1,797 "# 1,528 "# 1,352 "# 952 "# 2 pin OK 2 pin OK 2 pin OK 2 pin OK 2 pin OK 2 pin OK 2 pin OK GRAINGER -M -060212 -7 -TYPE 161J20 SELECTIVE RACK Page 4 of l S- oil G/201 2 Str ctural oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: GRAINGER Seismic Forces Configuration: TYPE 16U20 SELECTIVE RACK Lateral analysis is performed with regard to the 2009 IBC Sec. 2208.1, 2008 RMI/ANSI MH 16.1 Sec 2.6 & ASCE 7 -05 sec 15.5.3 Transverse (Cross Aisle) Seismic Load V= Cs *Ip *Ws =Cs *Ip *(0.67 *LL*PLrf +DL) Csl= [Sds /R] * 0.67 = 0.1544 Cs2= 0.044 *Sds *0.67 = 0.0272 Cs3= [0.5 *S1 /R]* 0.67 = 0.0395 Cs -max= 0.1544 0. Extor pr RM( ma67 Sec u A Sa zJ Lim! Rataraa3rtln 4c. Am laxity Base Shear Coeff =Cs= 0.1544 ASD Format Loads Level 1 2 3 4 5 6 7 8 PRODUC LOAD/LVL,PL 1,200 lb 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib Cs -max * Ip= 0.1544 Vnun= 0.015 Eff Base Shear =Cs= 0.1544 Ws= (0.67 *PtR„ * PL) +DL = 7,2321b vt Project #: M -080212 -7 Transverse Elevation Vtransv =Vt= 0.1544 * (800 Ib + 6432 lb) EL= 1,1171b ASD Level Transverse seismic. shear per upright PL *0.67 *PLrf DL 8041b 1001b 8041b 100 lb 8041b 1001b 804 Ib 100 Ib 8041b 1001b 8041b 1001b 8041b 100 lb 804 Ib 100 Ib hi 8 in 32 in 56 in 80 in 104 in 128 in 152 in 192 in vvi *hi 7,232 28,928 50,624 72,320 94,016 115,712 137,408 173,568 Ss= 51= Fa= Fv= Sds= 2 /3 *Ss *Fa= Sd1= 2/3 *51 *Fv= Ca= 0.4 *2 /3 *Ss *Fa= (Transverse, Braced Frame Dir.) R= II Ip= P�RF1= Pallet Height =hp= DL per Beam Lvl= F 11.9 Ib 47.5 Ib 83.2 Ib 118.8 Ib 154.5 Ib 190.1 Ib 225.8 Ib 285.2 Ib 1.383 0.472 1.000 1.528 0.922 0.481 0.3688 4.0 1.0 `T.0,.: 20.0 in 100 Ib Fi *(hi +hp /2) 214-# 1,995 -# 5,491 -# 10,692 -# 17,613 -# 26,234-# 36,580 -# 57,610 -# sum: 9,600 Ib 6,432 Ib Longitudinal (Downaisle) Seismic Load !Similarly for longitudinal seismic loads, using R =6.0 Cs 1 =Sd1/(T*R)= Cs2= Cs3= Cs -max= Level 1 2 3 4 5 6 7 8 800 Ib W=7232 Ib 679,808 1,117 Ib 2= 156,429 0.0537 0.0272 0.0264 0.0537 PRODUC LOAD/LVL,PL 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib 1,200 Ib Ws= (0.67 * PLC * PL) + DL = 7,232 Ib Cs= Cs- max*Ip= 0.0537 PLRF2= 1.0 (Longitudinal, Unbraced Dir.) R= C.0 T= 1.00 sec Vlong= 0.0537 * (800 Ib + 6432 Ib) EL= 388 lb ASD Leve7Longit seismic shear per upright PL *0.67 *PLrf 804 Ib 804 Ib 804 Ib 804 Ib 804 Ib 804 Ib 804 Ib 804 Ib DL 100 Ib 100 Ib 100 Ib 100 Ib 100 Ib 100 Ib 100 Ib 100 Ib hi 8 in 32 in 56 in 80 in 104 in 128 in 152 in 192 in wi *hi 7,232 28,928 50,624 72,320 94,016 115,712 137,408 173,568 4.1 Ib 16.5 Ib 28.9 Ib 41.3 Ib 53.7 Ib 66.0 Ib 78.4 Ib 99.1 Ib Front View sum: 6,432 Ib 800 Ib W= 7232 Ib GRAINGER -M -0802 12 -7 -TYPE 1 6020 SELECTIVE RACK 679,808 388 Ib Page S of 1 S- 81 1 6/20 12 StrturaI oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: GRAINGER Project #: M -080212 -7 Downaisle Seismic Loads Configuration: TYPE 16U20 SELECTIVE RACK Determine the story moments by applying portal analysis. The base plate is assumed to provide no fixity. Seismic Story Forces Vlong= 3881b Vco1= Vlong /2= 194 Ib F1= 4lb F2= 17 Ib F3= 29 Ib Seismic Story Moments Typical frame made Tributary area of two columns of rack frame Nws E+ 143- 96 $j s. Front View Conceptual System 2 Side View Typical Frame made of two columns a ili � iji!e iI Top View Mbase -max= 0 in -Ib < = == Default capacity Mbase -v= (Vcol *hleff) /2 = 485 in -Ib < = == Moment- going to base Mbase -eff= Minimum of Mbase -max and Mbase -v = 0 in -Ib PINNED BASE ASSUMED M 1 -1= [Vcol * hleff] -Mbase -eff M 2 -2= [Vcol- (F1) /2] * h2 = (194 Ib * 5 in) -0 in -Ib = [194 Ib - 8.3 Ib] *24 in /2 = 970 in -Ib = 2,303 in -Ib hl -eff= hl - beam clip height/2 = 5 in Vcol Mseis= (Mupper +Mlower) /2 Mseis(1 -1)= (970 in -Ib + 2303 in-lb)/2 Mseis(2 -2)= (2303 in -Ib + 2204 in-lb)/2 = 1,637 in -Ib = 2,254 in-lb Beam to Column Elevation Summary of Forces LEVEL 1 hi Axial Load Column Moment Mseismic Mend -fixity Mconn ** Beam Connector 8 in 5,200 Ib 970 in -Ib 1,637 in -Ib 774 in -Ib 1,808 in -Ib 2 pin OK 2 24 in 4,550 Ib 2,303 in -Ib 2,254 in-lb 774 in -Ib 2,271 in -Ib 2 pin OK 3 24 in 3,900 Ib 2,204 in -Ib 2,118 in -Ib 774 in -Ib 2,169 in -Ib 2 pin OK 4 24 in 3,250 Ib 2,031 in -Ib 1,907 in -Ib 774 in -Ib 2,011 in -Ib 2 pin OK 5 24 in 2,600 Ib 1,783 in -Ib 1,622 in -Ib 774 in -Ib 1,797 in -Ib 2 pin OK 6 24 in 1,950 Ib 1,461 in -Ib 1,263 in -Ib 774 in -Ib 1,528 in -Ib 2 pin OK 7 24 in 1,300 Ib 1,065 in-Ib 1,028 in -Ib 774 in -Ib 1,352 in -Ib 2 pin OK 8 40 in 650 Ib 991 in -Ib 496 in -Ib 774 in -Ib 952 in -Ib 2 pin OK Mconn= (Mseismic + Mend -fixity) *0.75 Mconn- allow(2 Pin)= 12,970 in -Ib GRAINGER -M -0802 12 -7 -TYPE 16U20 SELECTIVE RACK Page 6 of 1 S 8/ 1 6/201 2 8trturaI oncepts Engineenng 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: GRAINGER Project #: M -080212 -7 Column (Longitudinal Loads) Configuration: TYPE 16U20 SELECTIVE RACK Conforms to the requirements of Chapter C5 of the AISI Cold Formed Steel Design Manual for combined bending and axial loads. Section Properties Section: Unarco TO1 25 3x1.625x12ga Aeff = 0.572 inA2 Ix = 0.882 inA4 Sx = 0.588 inA3 rx = 1.240 in clf= 1.67 E= 29,500 ksi Loads Considers Toads at level 1 Iy = 0.214 in ^4 Sy = 0.257 inA3 ry = 0.612 in Fy= 55 ksi Cmx= 0.85 Kx = 1.7 Lx = 22.2 in Ky = 1.0 Ly = 42.0 in Cb= 1.0 1,c, 3.000 in x , y - -- j- -- -r 1 10.100 in I=1_0.75 in 1.625 in COLUMN DL= 400 Ib COLUMN PL= 4,800 Ib Mcol= 970 in -Ib 0.11Sds= 0.10142 0.14Sds= 0.12908 Axial Analysis Critical load case RMI Sec 2.1, item 4: (1 +0.11Sds)DL + (1 +0.14SDS)PL *0.75 +EL *0.75 <= 1.0, ASD Method Axial Load =P= (1. 10142 *400Ib) +(1.12908 *48001b*0.75) = 4,505 Ib Moment =Mx= Mcol *0.75 = 970 in -Ib * 0.75 = 728 in -Ib KxLx/rx = 1.7 *22.2271.24" KyLy /ry = 1 *4270.6115" = 30.5 = 68.7 Fe= n ^2E /(KL/r)max ^2 = 61.7ksi Pn= Aeff*Fn = 24,451 Ib P /Pa= 0.35 > 0.15 Bending Analysis Fy /2= 27.5 ksi Qc= 1.92 Fe > Fy /2 Fn= Fy(1-Fy /4Fe) = 55 ksi *[1 -55 ksi /(4 *61.7 ksi)] = 42.7 ksi Pa= Pn /Qc = 24451 Ib/1.92 = 12,735 Ib Check: P /Pa + (Cmx *Mx) /(Max *px) <_ 1.0 P /Pao + Mx/Max <_ 1.0 Pno= Ae *Fy = 0.572 in ^2 *55000 psi = 31,460 Ib Max= My /Of = 32340 in- Ib/1.67 = 19,365 in -Ib px= {1 /[1- (S2c *P /Pcr)] }A -1 = {1/[1- (1.92 *4505Ib /35321 Ib)] }A -1 = 0.76 Combined Stresses Pao= Pno /5 c = 314601b/1.92 = 16,3851b Myield =My= Sx *Fy = 0.588 inA3 * 55000 psi = 32,340 in -Ib Pcr= nA2EI /(KL)maxA2 = nA2 *29500000 psi /(1 *42 in)A2 = 35,321 Ib (4505 Ib/12735 Ib) + (0.85 *728 in- Ib)/(19365 in -lb *0.76) = (4505 lb/16385 Ib) + (728 in- lb/19365 in -Ib) = 0.40 < 1.0, OK 0.31 < 1.0, OK (EQ C5 -1) (EQ C5 -2) GRAINGER -M -0802 12 -7 -TYPE 16U20 SELECTIVE RACK Page 7 of s- 8/ 1 6/201 2 Stricture! on is Y." ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: GRAINGER BEAM Configuration: TYPE 16U20 SELECTIVE RACK Project #: M- 080212 -7 DETERMINE ALLOWABLE MOMENT CAPACITY A) Check compression flange for local buckling (B2.1) w= c - 2 *t -2 *r = 1.75 in - 2 *0.067 in - 2 *0.067 in = 1.482 in w /t= 22.12 1= lambda= [1.052/(k) ^0.5] * (w /t) * (Fy /E) ^0.5 = [1.052/(4) ^0.5] * 22.12 * (55/29500) ^0.5 = 0.502 < 0.673, Flange is fully effective B) check web for local budding per section b2.3 fl(comp)= Fy *(y3 /y2)= 48.91 ksi f2(tension)= Fy *(y1 /y2)= 100.68 ksi Y= f2 /f1 Eq. B2.3 -5 _ -2.058 k= 4 + 2 *(1 -Y) ^3 + 2 *(1 -Y) Eq. B2.3 -4 = 67.31 flat depth =w= yl +y3 = 3.292 in w /t= 49.13432836 OK 1= lambda= [1.052/(k) ^0.5] * (w /t) * (f1/E) ^0.5 = [1.052/(67.31) ^0.5] * 3.292 * (48.91/29500) ^0.5 = 0.257 < 0.673 be =w= 3.292 in b2= be /2 b1= be(3 -Y) = 1.65 in = 0.651 b1 +b2= 2.301 in > 1.0764 in, Web is fully effective Determine effect of cold working on steel yield point (Fya) per section A7.2 Fya = C*Fyc + (1 -C) *Fy (EQ A7.2 -1) Lcomer =Lc= (p /2) * (r + t/2) 0.158 in C= 2 *Lc/(Lf +2 *Lc) Lflange- top =Lf= 1.482 in = 0.176 in m= 0.192 *(Fu /Fy) - 0.068 (EQ A7.2 -4) = 0.1590 Bc= 3.69 *(Fu /Fy) - 0.819 *(Fu /Fy)^2 - 1.79 = 1.427 since fu /Fv= 1.18 < 1.2 and r /t= 1 <7OK then Fyc= Bc * Fy /(R/t)^m (EQ A7.2 -2) = 78.485 ksi Thus, Fya -top= 59.13 ksi (tension stress at top) Fya- bottom= Fya *Ycg /(depth -Ycg) = 114.78 ksi (tension stress at bottom) Check allowable tension stress for bottom flange Lflange- bot =Lfb= Lbottom - 2 *r * -2 *t = 2.482 in Cbottom =Cb= 2 *Lc /(Lfb +2 *Lc) = 0.113 Fy- bottom =Fyb= Cb *Fyc + (1- Cb) *Fyf = 57.65 ksi Fya= (Fya- top) *(Fyb /Fya- bottom) = 29.70 ksi if F= 0.95 Then F *Mn= F*Fya *Sx= 18.85 in -k Eq. B2.1 -4 Eq. B2.1 -1 Eq B2.3 -2 (EQ A7.2 -3) 3.560 in 2.75 in 1.75 in Beam= Unarco 4356 3.56 "xi4aa Ix= Sx= Ycg= t= Bend Radius =r= Fy =Fyv= Fu =Fuv= E= top flange =b= bottom flange= Web depth= 1.285 in ^4 0.668 in ^3 2.350 in 0.067 in 0.067 in 55.00 ksi 65.00 ksi 29500 ksi 1.750 in 2.750 in 3.560 in Fy yl= Ycg -t -r= 2.216 in y2= depth -Ycg= 1.210 in y3= y2 -t -r= 1.076 in Str tural �on is ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: GRAINGER Project #: M- 080212 -7 BEAM Configuration: TYPE 16U20 SELECTIVE RACK RMI Section 5.2, PT II Section Beam= Unarco 4356 3.56 "xl4ga Ix =Ib= 1.285 in ^4 Sx= 0.668 in ^3 t= 0.067 in Fy =Fyv= 55 ksi Fu =Fuv= 65 ksi Fya= 59.1 ksi Bending E= 29500 ksi F= 150.0 L= 144 in Mcenter =F*Mn= W *L *W *Rm /8 W =LRFD Load Factor= 1.2 *DL + 1.4 *PL +1.4 *(0.125) *PL FOR DL =2% of PL, RM122, item 5 W= 1.599 Rm= 1 - [(2 *F*L) /(6 *E *Ib + 3 *F *L)] 1 - (2 *150 *144 in) /[(6 *29500 ksi *1.285 in ^3) +(3 *150 *144 in)] = 0.852 if F= 0.95 Then F *Mn =F *Fya *Sx = 37.52 in -k Thus, allowable load per beam pair =W= F*Mn *8 *(# of beams) /(L *Rm *W) = 37.52 in -k * 8 * 2/(144in * 0.852 * 1.599) = 3,061 lb/pair Mend= W *L *(1 -Rm) /8 = (3061 Ib /2) * 144 in * (1- 0.852)/8 = 4,077 in-lb Deflection 3.560 in 2.75 in 1.75 in Dmax= Dss *Rd Rd= 1 - (4 *F *L) /(5 *F *L + 10 *E *Ib) = 1 - (4 *150 *144 in) /[(5 *150 *144 in) +(10 *29500 ksi *1.285 in ^4)] = 0.823 in if Dmax= L/180 and Dss= 5 *W *123/(384 *E *Ib) L/180= 5 *W *L ^3 *Rd /(384 *E *Ib *# of beams) solving for W yields, W= 384 *E *I *2/(180 *5 *L ^2 *Rd) 384 *1.285 in ^4 *2/[180 *5 *(144 in) ^2 *0.823 1,895 Ib /pair Allowable load= 1,895 lb/pair .1 C- 1 r Structural is ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: GRAINGER Project 11: M-0802 1 2 -7 2 Pin Beam to Column Connection TYPE 16U20 SELECTIVE RACK I he beam end moments shown herein show the result of the maximum induced hxed end monents form seismic + static loads and the code mandated minimum value of 1.5 %(DL +PL) Mconn max= (Mseismic + Mend - fixity) *0.75 = 2,271 in -Ib Load at level 2 Shear Capacity of Pin Connector Type= 2 Pin Pin Diam= 0.44 in Fy= 55,000 psi Ashear= (0.438 in)^2 * Pi /4 = 0.1507 inA2 Pshear= 0.4 * Fy * Ashear = 0.4 * 55000 psi * 0.1507inA2 = 3,315 Ib Bearing Capacity of Pin tcol= 0.100 in Fu= 65,000 psi Omega= 2.22 a= 2.22 Pbearing= alpha * Fu * diam * tcol /Omega = 2.22 * 65000 psi * 0.438 in * 0.1 in/2.22 = 2,847 Ib < 3315 Ib Moment Capacity of Bracket Edge Distance =E= 1.00 in C= P1 +P2 = P1 +P1 *(0.5 "/4.5 ") = 1.11 * P1 Pin Spacing= 4.0 in Fy= 55,000 psi Mcap= Sclip * Fbending = 0.127 inA3 * 0.66 * Fy = 4,610 in -Ib Pclip= Mcap /(1.11 * d) = 4610.1 in-lb/(1.11 * 0.5 in) = 8,3061b tdip= 0.18 in Sdip= 0.127 inA3 Mconn - allow= [P1 *4.5"+P1 *(0.5'/4.5 ") *0.5 "] = 2847 LB *[4.5' +(0.5/4.570.5 "] = 12,970 in -Ib > Mconn max, OK C *d= Mcap = 1.11 Thus, P1= 2,847 Ib d= E/2 = 0.50 in GRAINGER -M -0802 12 -7 -TYPE I GU20 SELECTIVE RACK Page 61 of 1 8/1C/2012 $trturaI oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: GRAINGER Project #: M -080212 -7 Transverse Brace Configuration: TYPE 16U20 SELECTIVE RACK Section Properties Diagonal Member= 2- 1 /4 "xl "xl6ga Area= 0.241 inA2 r min= 0.311 in Fy= 55,000 psi K= 1.0 Qc= 1.92 Frame Dimensions 2.250 in - 1 0.060 in LL Horizontal Member= 2-1 /4 "x1 "xl6ga Area= 0.241 inA2 r min= 0.311 in Fy= 55,000 psi K= 1.0 2.250 In H 1 0.060 in 1.000 in Bottom Panel Height =H= 42.0 in Frame Depth=D= 36.0 in Column Width =B= 1.6 in Diagonal Member Clear Depth= D-B *2= 32.8 in X Brace= NO Critical load case RMI Sec 2.1, item 4: (1 +0.11Sds)DL + (1+0.14SDS)PL *0.75 +EL *0.75 <= 1.0, ASD Method, DL =PL =0 for upright brace members Vb= Vtransv= 1,117 Ib Ldiag= [(D- B *2)A2 + (H -6" )A2]A1 /2 = 48.7 in Pmax= V *(Ldiag /D) * 0.75 = 1,1331b Pn= AREA *Fn = 0.241 inA2 * 11872 psi = 2,861 Ib Pallow= Pn /S2 = 2861 Ib /1.92 = 1,4901b Pn /Pallow= Horizontal brace 0.76 <= 1.0 OK (kl /r)= (k * Ldiag) /r min = (1 x 48.7 in /0.311 in ) = 156.6 in Fe= piA2 *E/(kI /r)A2 = 11,872 psi SINCE Fe<Fy /2, Fn= Fe = 11,872 psi 3" typ B +1' Typical Panel Configuration Check End Weld Lweld= 2.5 in Fu= 65 ksi tmin= 0.060 in Weld Capacity= 0.75 * tmin * L * Fu /2.5 = 2,925 Ib OK Pmax =V= 838 Ib (kl /r)= (k * Lhoriz) /r min = (1 x 36 in) /0.311 in = 115.8 in Since Fe <Fy /2, Fn =Fe = 21,712 psi Pn /Pallow= 0.41 <= 1.0 OK Fe= piA2 *E /(ki /r)A2 Fy /2= 27,500 psi = 21,712 psi Pn= AREA *Fn = 0.241inA2 *21712 psi = 5,233 Ib Fallow= Pn /4c = 5233 Ib /1.92 = 2,725 Ib GRAINGER -M -0802 12 -7 -TYPE 16U20 SELECTIVE RACK Page ' 0 of 1 S.— 8/ 1 6/20 12 Strturai oncepts ineerin n 9 9 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: GRAINGER Project #: M -080212 -7 Single Row Frame Overturning Configuration: TYPE 16U20 SELECTIVE RACK Loads Load case per RMI Sec 2.1, item 3: (0.6- 0.11Sds)DL + (0.6- 0.14Sds)PLapp *0.75 - EL *0.75 Vtrans =V= 1,117 Ib DEAD LOAD PER UPRIGHT =DL= 800 Ib PL PER UPRIGHT =PL= 9,600 Ib PLapp =PL *0.67= 6,432 Ib Wst= (0.49858 *DL +0.47092 *PLapp *0.75)= 2,670 Ib PL @ TOP= 1,200 Ib DL/Lvl= 100 Ib E(Fi*hi)= 156,429 in -Ib Total Dead Load per Bay =DL= 800 Ib Load Case 1: FuIIy Loaded rack (0.6- 0.11Sds)= 0.4986 (0.6- 0.14Sds)= 0.4709 Frame Depth=D= 36.0 in Htop- IvI =H= 192.0 in # Levels= 8 # Anchors /Base= 2 h= 202.0 in hp= 20.0 in -44D� SIDE ELEVATION Vtrans= 1,117 Ib Movt= E(R *hi) *0.75 = 117,322 in -lb Load Case 2: Top Level Loaded Only Mst= Wst * D/2 = 2670 Ib * 36 in /2 = 48,060 in -Ib T= (Movt- Mst) /D = (117322 in -Ib - 48060 in-lb)/36 in = 1,924 lb Net Uplift per column c tical Level= 8 Anchor h= 202.0 in V1 =Vtop= Cs * Ip * Ws Pinned Base Movt= [V1 *h + V2 * H /2] *0.75 = 0.1544 * (1200 Ib) = [185 lb*202 in +123 Ib *192 in /2] *0.75 = 185 Ib = 36,884 in -Ib V2=VDL= Cs *Ip *DL = 123 Ib T= (Movt- Mst) /D Mst= (0.49858 *DL +0.47092 *PL *0.75) * D/2 = (36884 in -Ib - 14808 in- Ib) /36 in = (100 lb*8 * 0.49858 + 1200 lb*0.47092*0.75)*36 in /2 = 613 Ib = 14,808 in -Ib Net Uplift per column Check (2) 0.5" x 3.25" Embed HILTI KWIKBOLT TZ anchor(s) per base plate. Special inspection is required per ESR 1917. Fully Loaded: Top Level Loaded: Pullout Capacity=Tcap= 1,520 Ib L.A. City Jurisdiction? NO Shear Capacity=Vcap= 1,840 Ib Phi= 1 Tcap *Phi= 1,520 Ib Vcap *Phi= 1,840 Ib (962 Ib/1520 Ib) ^1 + (279 Ib/1840 Ib) ^1 = (307 lb /1520 Ib) ^1 + (46 Ib/1840 Ib) ^1 = 0.78 <= 1.2 OK 0.23 <= 1.2 OK GRAINGER -M -0802 12 -7 -TYPE ICI 120 EL[CIIVE RACK Page of ) 81 1 6/20 12 Strturai oncepts _-__ 4 Enguneerung 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: GRAINGER Project #: M -080212 -7 Base Plate Configuration: TYPE 16U20 SELECTIVE RACK Section Baseplate= 7 in x 5 in x 0.375 in Eff Width =W = 7.00 in Eff Depth =D = 5.00 in Column Width =b = 3.00 in Column Depth =dc = 1.63 in L = 2.00 in Plate Thickness =t = 0.375 in a = 2.50 in Anchor c.c. =2 *a =d = 5.00 in N =# Anchor /Base= 2 Fy = 36,000 psi Downaisle Elevation Down Aisle Loads Critical load case RMI Sec 21, item 4: (110.11Sds)DL t (1+0.14SDS)PL *0.75 #EL *0.75 <= 1.0, ASD Method COLUMN DL= 400 Ib COLUMN PL= 4,800 Ib Base Moment= 0 in -Ib 0.11Sds= 0.10142 0.14Sds= 0.12908 Axial =P= (1.10142 *400 Ib)+(1.12908*4800 Ib*0.75) = 4,505 Ib I Axial Load P = 4,505 Ib Mb= Base Moment*0.75 = 0 in -Ib * 0.75 = 0 in -Ib Mbase =Mb = 0 in -Ib Axial stress =fa = P/A = P /(D *W) 129 psi Moment Stress =fb = M/S = 6 *Mb /[(D *B ^2] = 0.0 psi Moment Stress =fbl = fb-fb2 = 0.0 psi M3 = (1 /2) *fb2 *L *(2/3) *L = (1 /3) *fb2 *LA2 = 0 in -Ib S -plate = (1)(t^2)/6 = 0.023 inA3 /in fb /Fb = Mtotal/[(S- plate)(Fb)] 0.41 OK Tanchor = (Mb- (PLapp *0.75 *0.46)(a)) /[(d) *N /2] = -1,335 Ib No Tension Cross Aisle Loads M1= wL ^2/2= fa*LA2/2 = 257 in -Ib Moment Stress =fb2 = 2 * fb * L/W = 0.0 psi M2= fbl *L ^2)/2 = 0 in -Ib Mtotal = M1 +M2 +M3 = 257 in -Ib /in Fb = 0.75 *Fy = 27,000 psi Pp= 0.7 *Fc = 1,750 psi OK Tallow= 1,520 Ib &Wad bald case ara Sec 2.1, den 4 (1-4.I1Sds)01 + (1+0.145D5)14.97.75+H'V.75 <a 1.0, ASO Method Pstatic= 4,505 Ib Movt *0.75= 117,322 in -Ib Frame Depth= 36.0 in 1 P= Pstatic +Pseismic= 7,764 Ib b = Column Depth= 1.63 in L =Base Plate Depth -Col Depth= 2.00 in fa = P/A = P /(D *W) = 222 psi Sbase /in = (1)(t ^2)/6 = 0.023 inA3 /in fb /Fb = M /[(S- plate)(Fb)] 0.70 OK Pseismic= Movt/Frame Depth = 3,2591b M= wL ^2/2= fa *L ^2/2 = 444 in -Ib /in Fbase = 0.75 *Fy = 27,000 psi OK Check uplift load on Baseplate ( Check uplift forces on baseplate with 2 or more anchors per RMI 7.2.2. the base plate configuration consists of two anchor bolts located on either side f the column and a net uplift force exists, the minimum base plate thickness hall be detemdned based on a design bending moment in the plate equal the uplift force on one anchor times 1/2 the distance from e centerline of the anchor to the nearest edge of the rack column" Ta Elevation Uplift per Column= 1,924 Ib Qty Anchor per BP= 2 Net Tension per anchor =Ta= 962 Ib c= 2.00 in Mu= Moment on Baseplate due to uplift= Ta *c /2 = 962 in -Ib Splate= 0.117 inA3 [fb /Fb] *0.75= 0.228 OK GRAINGER -M -0802 12 -7 -TYPE 1 GU2O SELECTIVE RACK Page 1 R, of 13- 8/IG/2012 Strturai oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: GRAINGER Project #: M -080212 -7 Slab on Grade Configuration: TYPE 16U20 SELECTIVE RACK 1111111111111111111111111111111111111111111 x -* k-- c -14 y L SLAB ELEVATION Base Plate Effec. Baseplate width =B= 7.00 in Effec. Baseplate Depth =D= 5.00 in Column Loads width =a= 3.00 in depth =b= 1.63 in Cross Aisle - Baseolate Plan View Concrete fc= 2,500 psi tslab =t= 5.0 in teff= 5.0 in phi =D= 0.6 Soil fsoil= 1,000 psf Movt= 117,321 in -Ib Frame depth= 36.0 in Sds= 0.922 0.2 *Sds= 0.184 midway cost face of column to edge of plate =c= 5.00 in midway (1st face of column to edge of plate =e= 3.31 in DEAD LOAD=DL= PRODUCT LOAD =PL= P- seismic =EL= Puncture 400 Ib per column unfactored ASD load 4,800 Ib per column unfadared ASD load (Movt/Frame depth) 3,258 Ib per column unfactored ASD load Load Case 1) (1.2 +0.2Sds *DL) + (0.85 +0.2Sds *PL) + 1.5 *EL RMI SEC 2.2 EQTN 5 = 1.3844*400 Ib + 1.0344*4800 Ib + 1.5*3258 Ib = 10,406 Ib Load Case 2) (0.9- 0.2Sds)DL + (0.9- 0.2Sds) *PLapp + 1.5EL RMI SEC 2.2 EQTN 6 = (0.7156 *400 Ib) + (0.7156 *3216 Ib) + (1.5 *3258 Ib) = 7,475 Ib Load Case 3) 1.2 *DL + 1.4 *PL RMI SEC 2.2 EQTN 2 = 1.2 *400 Ib + 1.4 *4800 Ib = 7,200 Ib Effective Column Load =Pu= 10,406 Ib per column Apunct= [(c +t) +(e +t)] *2 *t = 183.13 in ^2 Slab Bending Fpunct= 2.66 *phi *sgrt(fc) = 79.8 psi fv /Fv= Pu /(Apunct *Fpunct) = 0.712 < 1 OK Pse= DL +PL +E= 10,406 lb Asoil= (Pse *144) /(fsoil) = 1,498 in ^2 x= (L-y) /2 = 12.3 in Fb= 5 *(phi) *(fc) ^0.5 = 150. psi L= (Asoil) ^0.5 = 38.70 in M= w *x ^2/2 = (fsoil *x ^2)/(144 *2) = 526.8 in -Ib y= (c *e) ^0.5 + 2 *t = 14.1 in S -slab= 1 *teff^2 /6 = 4.17 in ^3 fb /Fb= M /(S- slab *Fb) = 0.843 < 1, OK GRAINGER-M-0802 1 2 -7 -TYPE 16U20 SELECTIVE RACK Page ( 3 of ' 8/16/2012 Structural Concepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632,7330 Fax: 714.632.7763 By S.P. Project: GRAINGER Protect A: M -080212 -7 Configuration & Summary: TYPE 16U20 SELECTIVE RACK 192" 52" 12" 24" 24" 24° 24" 24" 144" 192• 16• 18• 48- 42- 42" 36" * *RACK COLUMN REACTIONS ASD LOADS AXIAL DL= 400 /b AXIAL LL= 3,300 /b SEISMICAXIAL Ps =t /- 2,641 /b BA.SEMOMENT= 0 in -lb Seismic Criteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss= 1.383, Fa =1 8 36 in 192.0 in 5 144 in Single Row Component Description STRESS Column Fy =55 ksi Unarco TO1 25 3x1.625x12ga P =3350 Ib, M =1668 in -Ib 0.28 -OK Column & Backer None None None N/A Beam Fy =55 ksi Unarco 4356 3.56'k14ga Lu =144 in Capacity: 1895 Ib /pr 0.79 -OK Beam Connector Fy =55 ksi LvI 7: 2 pin OK I Mconn =1423 in -Ib Mcap =12970 in -Ib 0.11 -OK Brace - Horizontal Fy =55 ksi 2- 1 /4 "x1 "xl6ga 0.3 -OK Brace - Diagonal Fy =55 ksi 2- 1 /4 "xI'xl6ga 0.55 -OK Base Plate Fy =36 ksi 7 in x 5 in x 0.375 in 1 Fixity= 0 in -Ib 0.53 -OK Anchor 2 per Base 0.5" x 3.25" Embed HILTI KWIKBOLTTZ ESR 1917 Inspection Reqd (Net Seismic Uplift= 1662Ib) 0.55 - OK Slab & Soil 5" thk x 2500 psi slab on grade. 1000 psf Soil Bearing Pressure 0.540K Level Load Per Level Beam Spcg Brace Story Force Transv Story Force Longit. Column Axial Column Moment Conn. Moment Beam Connector 7 1,500 Ib 12.0 in 218 Ib 76 Ib 1,600 Ib 539 "# 1,423 "# 2 pin OK 8 1,500 Ib 52.0 in 299 Ib 104 Ib 800 Ib 1,348 "# 1,221 "# 2 pin OK Total: 8061b 2801b Notes GP,AINGER -M -08O2 12 -7 -TYPE 1 GTU SELECTIVE RACK Page 1 4. of 1 s--- 5/1 G/201 2 Structural Concepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By S.P. Project: GRAINGER Project at M- 080212 -7 Configuration & Summary: TYPE 16MBZ10 SELECTIVE RACK TfPC 116MM 10,f BGit C, CANTILEVER RACK f; -6‘) y _ - * *RACK COLUMN REACTIONS ASD LOADS AXIAL DL= 200 /b AXIAL LL= 4,000 /b SEISMIC AXIAL Ps = +/- 2,912 /b BASE MOMENT= 0 in -lb Seismic Criteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss= 1.383, Fa =1 4 36 in 192.0 in 5 144 in Single Row Component Description STRESS Column Fy =55 ksi Unarco TO1 25 3x1.625x12ga P =3400 Ib, M =4412 in -Ib 0.34 -OK Column & Backer None None None N/A Beam Fy =55 ksi Unarco 4356 3.56 "x14ga Lu =144 in Capacity: 1895 Ib /pr 0.79 -0K Beam Connector Fy =55 ksi Lvl 1: 2 pin OK I Mconn =2334 in -Ib Mcap =12970 in -Ib 0.18 -OK Brace - Horizontal Fy =55 ksi 2- 1 /4 "x1 "xl6ga 0.33 -OK Brace - Diagonal Fy =55 ksi 2 -1 /4'x1 "x16ga 0.61 -OK Base Plate Fy =36 ksi 7 in x 5 in x 0.375 in I Fixity= 0 in -Ib 0.59 -OK Anchor 2 per Base 0.5" x 3.25" Embed HILTI KWIKBOLT TZ ESR 1917 Inspection Reqd (Net Seismic Uplift =1866 Ib) 0.608 - OK Slab & Soil 5" thk x 2500 psi slab on grade. 1000 psf Soil Bearing Pressure 0.64--OK Level Load Per Level Beam Spcg Brace Story Force Transv Story Force Longit Column Axial Column Moment Conn. Moment Beam Connector 1 1,500 Ib 8.0 in 42.0 in 14 Ib 5 Ib 4,200 Ib 773 "# 2,334 "# 2 pin OK 2 2,750 Ib 3 2,250 Ib 4 1,500 Ib 58.0 in 78.0 in 48.0 in 42.0 in 48.0 in 18.0 in 18.0 in 196 Ib 354 Ib 325 Ib 68 Ib 123 Ib 113 Ib 3,400 Ib 1,975 Ib 800 Ib 4,412 "# 4,604 "# 1,355 "# 4,097 "# 2,820 "# 898 "# 2 pin OK 2 pin OK 2 pin OK Total: 889 Ib 309 Ib Notes ITHIS UNIT HAS CENTER SUPPORT COL 3 "x3 "xl2ga WITH RIGHT /LEFT HAND CANTILEVER ARMS 16.5" LONG. THE LOAD FOR CLIPPED ARM IS ASSUMED 250# & IS ADDED @ LVLS 2 & 3 FOR ANALYSIS. GRAINGER -M -0502 12-7-TYPE I GMB210 SELECTIVE_ RACK Page I of 1 s- 0/16/2012 • • OFF HOURS INSPECTION Reimbursement authorization/approval to conduct inspection activities during off hours. Date: 6/3O//2 / Permit Number: (-2-- -2104. Requested By: 52-6-arr./ �- / ccc0/44/.8-z/.. l r (G,rarr -/ 65,4) Firm /Company: e-<)%vg /b N r 'o.cloO,,Anor' Inspection Information Project Name: fz,41...iG6eg % X i wool p•1C.uCAno)t 1q ✓,!e )cGore9 /CG,COSr L /6Nr2►4G Project Address /Location: 6725" 7o10 ieGVJ• TKw/ .A &',4 /(0'088 Requested Date for Inspection: 7as4,oi, ju).+a '013 Requested Time: *30 AM( 375irs Gru cw.d 9I/7- 4.34-58Z6 Contact Name: IDA,t.,c Phone Number: 426 - .734. - •r 2.1 Special Conditions for Consideration: 5/116,465,4G47 INA &toss L /�,�T1t•G ./%N� �,� �i�sS ✓csc�iok �.yAG ** Contractor will be charged a minimum for four (4) hour inspection time for any off -hours inspection work at $94.50 per hour (minimum total of $378.00). This is to be paid at the time of request. ** The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of (4) hours. Signature: -7� Printed Name: T 4G I4 Date: 051 31 / 13 RECEIVED CIW OF iuKan to City Use Only: Approved: Disapproved: Remarks: Date of Approval/Disapproval: �p Authorized Reviewer: ply 3-f20I3 PERMIT CENTER W: \Permit Center \Templates \Forms \Off Hours Inspection.docx November 14, 2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Dan O'Reilly 2500 York Road Elk Grove Village, IL 60007 RE: Incomplete Letter #1 to Correction Letter #1 Development Permit Application Number D12 -305 Grainger — 6725 Todd BI Dear Mr. O'Reilly, This letter is to inform you that your response to Correction Letter #1 received at the City of Tukwila Permit Center on November 9, 2012 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions regarding the attached comments. Please address the comments above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Jenn f Ma ' e it\Tech File No. DI2 -305 shall ician W :1Permit CenterlIncomplete Letters 20l21Dl2 -305 Inc #! to Corr #l.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: November 14, 2012 Project Name: Grainger Permit #: D12 -305 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall be original signed wet stamped, not copied. Architectural design sheets and documents by a registered architect shall also be original signed wet stamped, not copied. 1. Previous memo was not adequately addressed as requested. [Provide a means of egress plan. Dimension egress and exit access pathways. Length of common path of egress travel in "S" occupancies (sprinkled building) shall not be more than 100 feet. Exit access travel distance shall not exceed 250 feet. Identify path of egress illumination on the plan to show common paths of egress are provided with emergency illumination. Emergency illumination shall have at least an average 1 foot - candle and a minimum at any point of 0.1 foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required for exit discharge doorways. Identify each exterior emergency exit doorways. (IBC Section 1006, 1008.1.6, 1014.3 Exception #1)] Since this plan for racks exceeds 4000 square feet of alterations to this warehouse rack layout and affects life safety issues, per the WAC 308 -12 -340 a registered design professional shall be required to design the emergency paths and lighting. Please provide an egress plan. The egress plan shall be designed by a registered architect. Sheets and documents provided by a registered engineer and those provided by a registered architect shall be wet stamped and signed by the design professionals specifically to their own design and documents. (WAC 308 -12 -340, RCW 18.08.410(7)) Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. • City ojTu lia Jim Haggerton, Mayor Department of Community Development Jack Pace, Director September 26, 2012 Dan O'Reilly 2500 York Road Elk Grove Village, IL 60007 RE: Correction Letter #1 Development Permit Application Number D12 -305 Grainger — 6725 Todd BI Dear Mr. O'Reilly, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. Sincerely, shall ician enc File No. D12 -305 460- W:\Perrnit Center\Correction Letters \2012012-305 Correction Letter #I.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Project Name: Grainger Permit #: D12 -305 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide a means of egress plan. Dimension egress and exit access pathways. Length of common path of egress travel in "S" occupancies (sprinkled building) shall not be more than 100 feet. Exit access travel distance shall not exceed 250 feet. Identify path of egress illumination on the plan to show common paths of egress are provided with emergency illumination. Emergency illumination shall have at least an average 1 foot - candle and a minimum at any point of 0.1 foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required for exit discharge doorways. Identify each exterior emergency exit doorways. (IBC Section 1006, 1008.1.6, 1014.3 Exception #1) Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. OPERMIT COORD COO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -305 PROJECT NAME: GRAINGER SITE ADDRESS: 6725 TODD BL DATE: 12/26/12 Original Plan Submittal Response to Correction Letter # 1 X Response to Incomplete Letter # 1 Revision # after Permit Issued DEPARTMENTS: Buildint Di ision Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete vz Incomplete ❑ DUE DATE: 12/27/12 Not Applicable ❑ Comments: ' Permit Center Use Only ' : INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 01/22/13 Approved ❑ Approved with Conditions N. Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center.Use:O1iy • • • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: OPER C,�:_ PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -305 PROJECT NAME: GRAINGER SITE ADDRESS: 6725 TODD BL Original Plan Submittal _ X Response to Correction Letter # 1 _ DATE: 11 -09 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPA THE TS: fit tO (2 Building Division is Public Works ❑ Fire Prevention Structural Planning Division n Permit Coordinator tal DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -13 -12 Complete ❑ Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: it It'1( LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 46 Fire ❑ Ping ❑ PW ❑ Staff Initials:iw TUES/THURS ROUTING: � Please Route 1-1 1 Structural Review Required I I No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12 -11 -12 Approved pi Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 ERMIT COORD COM PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -305 DATE: 09/17/12 PROJECT NAME: GRAINGER SITE ADDRESS: 6725 TODD BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued EPAR MEN : ding Division Public Works ❑ ( 01'25"0 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) I�I Complete Incomplete I I DUE DATE: 09/18/12 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TOES /THURS ROUTING: Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Not Approved (attach comments) kV Notation: DUE DATE: 10/16/12 REVIEWER'S INITIALS: DATE: Permit Center Use Only - CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: l2IZu I 12 Plan ChecWPermit Number: D12-305 ® Response to Incomplete Letter # 1 • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner DIY OF itoniotA DEC 2 6 2012 PERMIT CENTER Project Name: Grainger Project Address: 6725 Todd Bl Contact Person: Corey McKinnon Phone Number: 253 872 -5553 Summary of Revision: Update general emergency and exit lighting in warehouse area Valuation of this work estimated at $40,000 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on C: \Users \jennifer- m\Desktop\Revision Submittal Form.doc Revised: May 2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 11/07/2012 Plan Check/Permit Number: D12 -305 Response to Incomplete Letter # ,/ Response to Correction Letter # 1 Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Grainger Project Address: 6725 Todd B1 Contact Person: Steve Gucwa Phone Number: (847) 436 -5820 Summary of Revision: The attached documents address the corrections request for the identification exit access paths and egress illumination. The attached drawing to be added to be added to the existing per it set ( Wynright / Sea -Tac Electric drawing SLOJ illustrates common egress paths of less than100 feet, with a maximum travel distances of less than 250 feet. In addition, this drawing identifies common paths of egress illumination along with emergency lighting at exit discharge doorways. The emergency illumination within these paths will have an average of 1 foot - candle and a minimum level 0.1 foot - candle measured at the floor level along any point of the egress path at the floor level. Sheet Number(s): SL01, SL02, SL03, SL04, & SL05. SLO5 is the revision. • "Cloud" or highlight all areas of revision including drneafyevispry1 —___a Received at the City of Tukwila Permit Center by: Entered in Permits Plus on IA -q. ( 1. H:Wpplications \Forms-Applications On Line \2010 Applications \7.2010 - Revision Submittal.doc Revised: May 2011 'CRY OF YUKWLL,A NGY 0.9 201Z! PERMITGENTER Contractors or Tradespeople ter Friendly Page General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company WYNRIGHT CORPORATION 8475959400 2500 York Rd Elk Grove Village IL 60007 Out Of State Corporation WYNRIGHT CORP UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 603047763 Active WYNRIC *907P9 Construction Contractor 10/29/2010 10/29/2014 Industrial Equipment /Machines Unused her Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status PACIFCS991NZSTRUCTURES PACIFIC COAST INC Construction Contractor Industrial Equipment /Machines Unused 8/9/2001 8/9/2010 Inactive Business Owner Information Name Role Effective Date Expiration Date AMBROSE, KEVIN HENRY President 10/03/2012 Bond Amount SCHECK, MICHAEL FRANK Secretary 10/03/2012 105488821 CARUSO, ANTHONY Treasurer 10/22/2012 SCHECK, MICHAEL F President 10/29/2010 10/03/2012 SIMKINS, JAMES A Secretary 10/29/2010 10/03/2012 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Travelers Cas and Surety Co of America 105488821 07/27/2011 Until Cancelled $6,000.00 09/26/2011 1 TRAVELERS CAS & STY CO OF AMER 104540412 10/29/2010 Until Cancelled 09/12/2011 $6,000.0007/18/2005 09/06/2011 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 National Fire Ins of Hartford 5088319503 09/01/2012 09/01/2013 $1,000,000.00 09/12/2012 1 ALLIED WORLD ASSURANCE CO 03058941 10/29/2010 09/01/2012 $1,000,000.00 09/06/2011 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 01/31/2013 1 22' -1 1/4" 47' -5 1/4" 50' -0" 48' -7 1/2" 51' -11 1/4" 47' -2 3/4" ®111111111_ 1 1 I II- i lk f -1 UP \- PHASE -I ti- I16U41 16U41 52' ;JP ` 52" UP A 16U20 16041 16041 16U41 16U41 16U41 16U41 1 52" 'JP ' S2" UP � 52' UP 52" UP 52° UP 52" UP 6U41 16U41 I 16U41 I 16U41 5.2" UP 52' UP 52' UP 52' UP SAME SAME r 52° UPrights _ _ 1 16U20 16U20 I 16U20 16U20 16U20 I 16U20 1' -4" A16U41 16041 16U41 16041 16TU SAME 16U20 I SAME I SAME I SAME I SAME 16U20 I 16TU 16U20 I 16U41 I 16U41 16U41 16U4 12U124 2U124 09 10 2U1241 11 2U1241 12 16U20 16U20 I 16U20 16U20 I 16U20 I 16U20 00 N N N N 16U20 116U20 ! 161120 I 16U20 I 16U20 I 16U20 16U20 B 16U20 16TU 16U20 I 16U20 I 16U20 I 16U20 16U20 -1 161120 16U20 I 1f3TT2n I 16U20 I 1J.J2O I 161120 I 16112.0 iaru 16U20 11 aAM 4 1RTT90 I,_ 1RiT2n SAME h_ SAME F I 16112n 1 SAME- SAMIi4.�SAM Ic,�'j�, AME _1-___111.114_ 16MRZ1�.I MR7.1O 41$MR7,10 I16MR710 B 16U20 SAME I SAME I SAME 16U20 SAME I SAME I 1 SAME I SAME 16TU 16U20 16U20 161J20 I 16U20 i 16U20 l 18U20 16U20 1 16U20 1 16U20 1 16U20 1 16U20 16TU 16U20 16U20 16U20 I co N N 16U20 16U20 _01 sI � � I IE 19 II y-1 SAME I SAME I SAME i 16U20 I SAME I SAME I SAME I SAME } 16TU 16MBZ10 I 1 MBZ10 116MBZ10 116MBZ10 16U20 16U20 * 16TU 18U20 16U20 I 16U20 1 I 16U20 t SAME 4 SAME h_ SAME F I 16112n 1 SAME- SAMIi4.�SAM Ic,�'j�, AME _1-___111.114_ 16MRZ1�.I MR7.1O 41$MR7,10 I16MR710 SAME SAME SAME 16U20 I SAME I SAME I SAME SAME 16TU 16MBZ10 I 1 SMBZ10 I 16MBZ10 16MBZ10 16U20 1 16U20 16U20 16U20 I 16U20 1 16U20 16U20 16U20 16TU9 16MBZ10 116MBZ10 116MBZ10 116MBZ10 1 -I \ REPLACE END FRAMES COLIMN PRO1EC10R$ — 1— TYP. FOR All IttCmuctom FRAMES (SEE E1.EYA010Mi CefIGU RATIONS DETAILS 16TU1 16MBZ10 116MBZ10 DETAILS) 116MBZ10 16U20 1 16U20 16U20 I 16U20 1 16U20 1 16U20 1 16U20 1 16U20 16U20 16U20 r 18u20 --I 164320-1- 16U26-- 1- 16tJ2O --1-r 16U2O_1 icU .-1 c cn .-i N N N N 0 co N to E I 16m—+ -A1 SAM AYE --9AME SAME SAME 1 SAME 1 SAME I 16TU 1 SAME 1 SAME SAME 1 SAME B SAME SAME SAME I SAME I 16TU I SAME I SAME SAME I SAME B SAME SAME SAME SAME 16TU SAME SAME 1: SAME 1 SAME SAME SAME S—I 16� -sA. Mfg- !IIE 1t77-SANE 11 SAME 1 SAME I SAME 1 SAME I 16TU I SAME I SAME SAME I SAM 6HC14 6HC14 L6HC14 ? s5 :JP UP 1 SPACER1 fiHC14 Y 1 I L6HC14 6HC14 UP P I� 1�- PHASE -III HI- DE NSI?Y 6HC14 L6HC14 SP.QCE rp 1 SPACERS UP SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION 1 0 z w CO z 0 0 PHASE -II MANIFEST SYSTEM II O co 10 0 2 0 2 0 N ro 7- 7- NEW WILL CALL OUTBOUND DOCKS CV CO —�° INBOUND DOCKS 2U124 13 40 N N 15 SF 2U12411.2U1241 14 15 0 m N CV N N m 0 0 o to o -o LO o N 1-1 0 E E CO CO CO CO rl m m tossoover mm O O 0 0 0 m m .. 0 N r0 m m m m 1-I CO treatsememma CO #1 #3 #4 #6 #7 1. 11E NUDISM SYSI N 11 THE MMI BBDNO 6 MUSED AS A 71EE, USING LANCE- pi10E. 216F RATED LEAS. SPACING DEISM HEADS ON A BRANCH LM 6 9 3 N. SPAOID WREN BUNCH IiES ‘1517.-111131E ME15411195813811119MCW011671WWWIT 1E41i- OBIECBD 10 A 6 IL NEER. lie SPINNER SYSEII WAS NiPLY2ED CM PRONE A M58 CEM/SO. FL OF)ISFIY OODR HE MOST ROOM 2.500 SO FT. NEA, PUS 500 GPII FOR STREAM 2. HE NORDER I SYSIFL 11 THE MAN MINDING 6 ARRAN= AS A LACE. USNiG LANCE- OREICE. NOT RAND LEADS SPACING B:TVON READS CH A BUNCH UK 6 9 F1 SPACNO LEWIN IRANCH LACES 6 10 FL HERE NE NNE HENS PER BRANCH UE. FRE NO FOUR ON EACH SIDE HE F® MAN 6 4 I MEMO TO A 6 N. RISER. RE SPINNER SYSFCI WAS AULYYD MD CAN PRONE A M8 GPM/SO. FL COMFIT MR RE MOST ROME $500 SO. FL AREA. PLUS 500 WM FOR HOSE SWAM - IELOlE4 OEBEILy 119115 IOG11B1 A- OFIIOIF3 EImi1M.Y ENO SCI IIfCJ1110N N N N N N N N 111 N n 03 40 ° O O 0 0 IE) 0 to m 0 .°1 0 0 0 CO 1-I E. E m E m CERS 2U1241 2U1241 16 17 2U124 120124 18 19 7 co• , m C‘2 CO CO CO .-1 m 0/ m CV CO CO CV a E. E C44) L2 m .-I 2 0 O p COco CO is 0 40 m d 0 40 Cpl 0 m .i 0 m 0 5 Hn 0 E m 40 m N N 22 I N n M 0 O 0 m 14 m m 40 a N N 14 N m m� .- .-I CO CO 40 m CV CV CO CO min 10 1-1 O cv mCO 01 CV m M V E E E m m ESE CV 00 00 co co m m o � 02 0 CO CO �5 5 CO m CA CA O 1-1 .-4 CDCO O ° O O 0 0 E. E. OED E CO 0 0 O %L, tiU CO CO CO CO N O' Dcri k CL O O u1 co X0 1 Zr CD 1 0 LO N 0 N P -- (0o oo co `: 0. EL 3`c c': L x GO M 0 0 O N) N 15' -0' ELECTRICA CHARC1 RS 8 REVISIONS No changes shall be made to the scope cf work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. TENANTIMPROVEMENT GRAINGER 6725 SOUTH TODD BLVD. TUKWILA, WA 96188 VICINITY MAP (NOT TO SCALE) DESCRIPTION OF WORK TO BE DONE NOTE: REVIEWED FOR CODE COMPLIANCE APPROVED JAN ?�.0!' 4 2013 City of Tulovila BUILDING OIVISION THE WORK TO BE PERFORMED WILL CONSIST OF THE DISMANTLE OF EXISTING DAMAGED STORAGE RACK IN AREAS DESIGNATED AS PHASES I, II, AND III. THE STORAGE RACK IN THESE AREAS WILL BE REPLACED WITH NEW COMPONENTS. ALONG WITH COMPONENT REPLACEMENT A NUMBER OF THE STORAGE LEVELS WILL BE RECONFIGURED AS SHOWN T bRMIT APPROVAL PLANS PROVIDED. permit No. Plan review approval is abject to errors and Mona &npr3val of constructkn documents does not auth : 7g r code or ordnance. Rem pt t%t 4o!ation of any adopted of approved F and nondilions is a :s ed: OWNER GRAINGER 100 GRINAGER PARKWAY LAKE FOREST, IL 60045 CONTACT: KEVIN DUHIG PHONE: 847 - 370 -3847 CONTRACTOR WYNRIGHT CORPORATION 2500 YORK RD. ELK GROVE VILLAGE, IL. 60007 CONTACT: PHONE: 847- 595 -9400 FAX: 847 - 595 -2126 TENANT GRAINGER 6725 SOUTH TODD BLVD. TUKWILA, WA 96188 CONTACT: DARREL LUFF PHONE: 425- 738 -6121 By : '� w/6 City Of 1Ukwila g NG DIVISION APPLE ANT WYNRIGHT CORPORATION 2500 YORK RD. ELK GROVE VILLAGE, IL. 60007 CONTACT: PHONE: 847 - 595 -9400 FAX: 847 - 595 -2126 STRUCTURAL ENGINEERING STRUCTURAL CONCEPTS ENGINEERING 1200 N. JEFFERSON ST, SUITE F ANAHEIM, CA 92807 CONTACT: BOB SHARIFI PHONE: 714 - 632 -7330 FAX: 714 - 632 -7763 facb- via) SEP 17 2012 PERMIT CENT A)12.-Soc DRAWING REVISIONS REV DESCRIPTION DATE BY Wynr.ght 2500 YORK ROAD ELK GROVE, IL 60007 1EL: (847) 595 -9400 FAX (647)595 -2128 CUSTOMER LOCATION GRAINGER TUKWILA, WA DRAWING TITLE JOB NUMBER SHEET THIS DOCUMENT IS CONFIDENTIAL PROPRIETARY INFORMATION OF weravotfr AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THIN FOR IMOCH IT IS SPECIFICALLY FURNISHED 1MTHOUT THE PRIOR WRITTEN CONSENT of WROUGHT. COVER SHEET 42164 SLOO SCALE (D -SIZE) DRAWN BY DATE REV. N.T.S. CDM 09/14/12 REPLACE (SET Elm TP. F FRA OR MES Attic CCUMN PROIECTDRSJ I4IJGHTED FRAMES ELEEYA110N C R:MATIONS DETAILS) 16U20 16U20 16U20 16U20 16TU 18U20 16U20 I 16U20 I 16U20 16U20 16U20 16U20 16U20 16TU 16U20 16U20 I 16U20 B 16U20 SAME SAME SAME SAME j 16TU SAME SAME I SAME I SAME B E I 16m—+ -A1 SAM AYE --9AME SAME SAME 1 SAME 1 SAME I 16TU 1 SAME 1 SAME SAME 1 SAME B SAME SAME SAME I SAME I 16TU I SAME I SAME SAME I SAME B SAME SAME SAME SAME 16TU SAME SAME 1: SAME 1 SAME SAME SAME S—I 16� -sA. Mfg- !IIE 1t77-SANE 11 SAME 1 SAME I SAME 1 SAME I 16TU I SAME I SAME SAME I SAM 6HC14 6HC14 L6HC14 ? s5 :JP UP 1 SPACER1 fiHC14 Y 1 I L6HC14 6HC14 UP P I� 1�- PHASE -III HI- DE NSI?Y 6HC14 L6HC14 SP.QCE rp 1 SPACERS UP SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION 1 0 z w CO z 0 0 PHASE -II MANIFEST SYSTEM II O co 10 0 2 0 2 0 N ro 7- 7- NEW WILL CALL OUTBOUND DOCKS CV CO —�° INBOUND DOCKS 2U124 13 40 N N 15 SF 2U12411.2U1241 14 15 0 m N CV N N m 0 0 o to o -o LO o N 1-1 0 E E CO CO CO CO rl m m tossoover mm O O 0 0 0 m m .. 0 N r0 m m m m 1-I CO treatsememma CO #1 #3 #4 #6 #7 1. 11E NUDISM SYSI N 11 THE MMI BBDNO 6 MUSED AS A 71EE, USING LANCE- pi10E. 216F RATED LEAS. SPACING DEISM HEADS ON A BRANCH LM 6 9 3 N. SPAOID WREN BUNCH IiES ‘1517.-111131E ME15411195813811119MCW011671WWWIT 1E41i- OBIECBD 10 A 6 IL NEER. lie SPINNER SYSEII WAS NiPLY2ED CM PRONE A M58 CEM/SO. FL OF)ISFIY OODR HE MOST ROOM 2.500 SO FT. NEA, PUS 500 GPII FOR STREAM 2. HE NORDER I SYSIFL 11 THE MAN MINDING 6 ARRAN= AS A LACE. USNiG LANCE- OREICE. NOT RAND LEADS SPACING B:TVON READS CH A BUNCH UK 6 9 F1 SPACNO LEWIN IRANCH LACES 6 10 FL HERE NE NNE HENS PER BRANCH UE. FRE NO FOUR ON EACH SIDE HE F® MAN 6 4 I MEMO TO A 6 N. RISER. RE SPINNER SYSFCI WAS AULYYD MD CAN PRONE A M8 GPM/SO. FL COMFIT MR RE MOST ROME $500 SO. FL AREA. PLUS 500 WM FOR HOSE SWAM - IELOlE4 OEBEILy 119115 IOG11B1 A- OFIIOIF3 EImi1M.Y ENO SCI IIfCJ1110N N N N N N N N 111 N n 03 40 ° O O 0 0 IE) 0 to m 0 .°1 0 0 0 CO 1-I E. E m E m CERS 2U1241 2U1241 16 17 2U124 120124 18 19 7 co• , m C‘2 CO CO CO .-1 m 0/ m CV CO CO CV a E. E C44) L2 m .-I 2 0 O p COco CO is 0 40 m d 0 40 Cpl 0 m .i 0 m 0 5 Hn 0 E m 40 m N N 22 I N n M 0 O 0 m 14 m m 40 a N N 14 N m m� .- .-I CO CO 40 m CV CV CO CO min 10 1-1 O cv mCO 01 CV m M V E E E m m ESE CV 00 00 co co m m o � 02 0 CO CO �5 5 CO m CA CA O 1-1 .-4 CDCO O ° O O 0 0 E. E. OED E CO 0 0 O %L, tiU CO CO CO CO N O' Dcri k CL O O u1 co X0 1 Zr CD 1 0 LO N 0 N P -- (0o oo co `: 0. EL 3`c c': L x GO M 0 0 O N) N 15' -0' ELECTRICA CHARC1 RS 8 REVISIONS No changes shall be made to the scope cf work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. TENANTIMPROVEMENT GRAINGER 6725 SOUTH TODD BLVD. TUKWILA, WA 96188 VICINITY MAP (NOT TO SCALE) DESCRIPTION OF WORK TO BE DONE NOTE: REVIEWED FOR CODE COMPLIANCE APPROVED JAN ?�.0!' 4 2013 City of Tulovila BUILDING OIVISION THE WORK TO BE PERFORMED WILL CONSIST OF THE DISMANTLE OF EXISTING DAMAGED STORAGE RACK IN AREAS DESIGNATED AS PHASES I, II, AND III. THE STORAGE RACK IN THESE AREAS WILL BE REPLACED WITH NEW COMPONENTS. ALONG WITH COMPONENT REPLACEMENT A NUMBER OF THE STORAGE LEVELS WILL BE RECONFIGURED AS SHOWN T bRMIT APPROVAL PLANS PROVIDED. permit No. Plan review approval is abject to errors and Mona &npr3val of constructkn documents does not auth : 7g r code or ordnance. Rem pt t%t 4o!ation of any adopted of approved F and nondilions is a :s ed: OWNER GRAINGER 100 GRINAGER PARKWAY LAKE FOREST, IL 60045 CONTACT: KEVIN DUHIG PHONE: 847 - 370 -3847 CONTRACTOR WYNRIGHT CORPORATION 2500 YORK RD. ELK GROVE VILLAGE, IL. 60007 CONTACT: PHONE: 847- 595 -9400 FAX: 847 - 595 -2126 TENANT GRAINGER 6725 SOUTH TODD BLVD. TUKWILA, WA 96188 CONTACT: DARREL LUFF PHONE: 425- 738 -6121 By : '� w/6 City Of 1Ukwila g NG DIVISION APPLE ANT WYNRIGHT CORPORATION 2500 YORK RD. ELK GROVE VILLAGE, IL. 60007 CONTACT: PHONE: 847 - 595 -9400 FAX: 847 - 595 -2126 STRUCTURAL ENGINEERING STRUCTURAL CONCEPTS ENGINEERING 1200 N. JEFFERSON ST, SUITE F ANAHEIM, CA 92807 CONTACT: BOB SHARIFI PHONE: 714 - 632 -7330 FAX: 714 - 632 -7763 facb- via) SEP 17 2012 PERMIT CENT A)12.-Soc DRAWING REVISIONS REV DESCRIPTION DATE BY Wynr.ght 2500 YORK ROAD ELK GROVE, IL 60007 1EL: (847) 595 -9400 FAX (647)595 -2128 CUSTOMER LOCATION GRAINGER TUKWILA, WA DRAWING TITLE JOB NUMBER SHEET THIS DOCUMENT IS CONFIDENTIAL PROPRIETARY INFORMATION OF weravotfr AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THIN FOR IMOCH IT IS SPECIFICALLY FURNISHED 1MTHOUT THE PRIOR WRITTEN CONSENT of WROUGHT. COVER SHEET 42164 SLOO SCALE (D -SIZE) DRAWN BY DATE REV. N.T.S. CDM 09/14/12 11 1 5/8" COLUMN NOTES: USE @ TYPE 16T20, 16TU- 192"T4. TYPE 16MBZ10 SELECTIVE RAM COLUMN /BASE LOCATIONS U.O.N. 1/8"/ <TYP. 1/8' 3" 3" r 12 GAGE COLUMN NOTES: --��YyD USE @ CENTER CANTILEVER SUPPOR -r1/8" / COLUMN /BASE LOCATIONS. 1/8" <TYP. TYP. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 4 2013 City of Tukwila UILDING DIVISION DESCRIPTION BASE PLATE: 7" x 5" MATERIAL STEEL YIELD 3/8" THICK PLATE DESCRIPTION COLUMN: UNARCO DESCRIPTION BASE PLATE: 7" x 5" DESCRIPTION COLUMN: UNARCO DESCRIPTION BRACING: HORIZ& DIAG. ASTM A36, Fy= 36.000 PSI MATERIAL STEEL YIELD 12 GAGE STEEL ASTM A570, Fy= 55.000 PSI MATERIAL STEEL YIELD 3/8" THICK PLATE MATERIAL 12 GAGE STEEL MATERIAL 16 GAGE STEEL ASTM A36, Fy= 36.000 PSI STEEL YIELD ASTM A570, Fy= 55.000 PSI STEEL YIELD ASTM A570, Fy= 36.000 PSI NOTES: USE @ SPECIFIED UNARCO BRACE LOCATIONS TYP. GENERAL PROJECT NOTES 1 DESIGNED PER REQUIREMENTS OF THE 2009 IBC, ASCE 7 -05, AND THE 2008 RMI RACK DESIGN MANUAL 2. SEISMIC CRITERIA Ss = 1.383, S1 = 0.472, Fa = 1.00, F• = 1.528 Ip = 1.0 (NO PUBLIC ACCESS), Sds = 0.922, Sd1 = 0.481, OCC. CATAG. II, SITE CLASS D, SEISMIC DESIGN CATAG. D 3. STORAGE CAPACITY: TYPE 16U20 = 1200# PER BEAM LEVEL TYPE 16TU = 1500# PER BEAM LEVEL TYPE 16MBZ10 = 1500# PER BEAM LEVEL TYPE 16MBZ10 @ CENTER COLUMN = 250# PER CUPPED ARM LEVEL 4. ANCHORS HILTI KWIK BOLT TZ , 1/200 X 3 -1 /4" MIN. EMBED OR ICC & ENGINEER APPROVED EQUAL. (2) ANCHOR PER BASEPLATE 5. PERIODIC SPECIAL INSPECTION REQUIRED DURING ANCHOR INSTALLATION. 6. EXISTING S.O.G. CONCRETE THICKNESS & COMPRESSIVE STRENGTH, 5" x 2500 PSI 7. SOIL BEARING PRESSURE 1000 PSF OR BETTER @ GRADE OR BETTER. 8. ALL RACK INSTALLATIONS AND RACKS MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA AND SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD IN CLEAR, LEGIBLE PRINT. 9. ALL BOLTS GR. 5 OR BETTER, INSTALL TO SNUG TIGHT FIT OR BETTER 10. ALL WELDING PERFORMED IN THE SHOP OF AN APPROVED FABRICATOR BY AWS CERTIFIED WELDERS USING E70XX ELECTRODE OR BETTER. FIELD WELD, IF ANY, SHALL BE PROVIDED UNDER THE SUPERVISION OF A LICENSED DEPUTY INSPECTOR. 11. THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MIN. OF 18" BETWEEN TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. 1/2 "O T -BOLT / 1 1/4" 1A 0,750 LS ! 0.750 it NGTEI ALL BENDS = 90°, ALL R40- = 125 EIRMING DETAIL 1.5 102- BILL 0 MATERIAL CT DESCRIPTION AVHATSEC- THK 0. STRIP WICTH 5.468 CUTOFF LENGTH 16.125 UNIT WEIGHT 2.557 TCA76L 0.:709 438 1.351 10014CAPLATE 0.06, '.6 3.062 0.096 0 :6.125 sci [25 16.500 1-3.062 -- r1.531� .;ee RAD. f cam; .375 DIA. hCLE-' END PLATO QUAL B0 sec SECTION B -H T]TA_ WIEGHT 3,997 SECTION A -A W. W. CRAINGER GUPTON NOT SCAM JJcM R &D 07/22/99 UNARCO. MATERIAL HANDLING 07/29/99 .17 XSP165LCRWW000A__ 2A .602 10' 63 1.750 i 38.438 O` TAI LO1 .500 all OF MATERIAL SHAPE CODE 999 OT. DESCRIPTION 067000000.000236 0.067 STRIP WIDTH 3.375 CUTOFF LENGTH 38.438' UN WEI( 2.563 -- 2.563 .875 --I 1.625 .56} 3 I. e94t .438 753 750- - 75C- 188- ,753 1.063 1125 1562 .030 RAC. ALL CORNERS , _E188 .1887 DETAI_C -2.000 1.750 1.500. 7 6_ '"IL0631°- e 6254- .500 DIA, HOLE 73 75 .094 RAE. (4 PLACES) 2.0 I jh ■-:438 15,250 1o250--- 1 J-7{` 36.063 W. W GRAINGER GUPTON TOLERANCE UNLESS N01E0 %DAC- 3.062 ANC- it 01.1. Gat[ JAM 09/30/99 LSNARCO MATERIAL HANDLING .SEE GNENSIGNE EMO"N 00 NOT ECA2 MALI N) .a •■.c. N. w.wa.. n OM. MOWS NO • 70 VW MAMMY .111.1M06 MA. 1.1r.01171 Cr AR R &D DATE 10/ 01/99 USED CN OS APYO CATS CAS ,G NO XT036ENDAWWGOOA DESCRIPTION T -BOLT CONNECTOR MATERIAL STEEL YIELD 7 GAGE ASTM A570, Fy= 55.000 PSI NOTES: USE @ ALL UNARCO BEAM TO COLUMN CONNECTION LOCATIONS TYP. DESCRIPTION MATERIAL LEFT & RIGHT CANTILEVER ARM 12 GAGE STEEL YIELD ASTM A570, Fy= 55.000 PSI NOTES: USE @ ALL TYPE 16MBZ10 ARM TO COLUMN CONNECTION LOCATIONS TYP. 2B BASE PLATE F.F. 3 1/4" MIN. EMBED. 1/2" DESCRIPTION HILTI KWIK BOLT TZ ANCHO DESCRIPTION ANGLE SUPPORT BRACKET MATERIAL 15 GAGE THK. STEEL MATERIAL 1/2" X 3 1/4" MIN. EMBED, ESR# O. SPECIAL INSPECTION FOR STORAGE RACKS (OVER 8 FEET) Periodic special inspection is required during the anchorage of access floors and storage racks 8 feet or greater in height in structures assigned to Seismic Design Category D, E or F. IBC 1707.5 and TABLE 1704.4 (4) Inspection of anchors installed in hardened concrete. Ns S 1917 SEE NOTE #4 ABOVE FOR ANCHOR SPECS 1B DESCRIPTION 3- 9/16" BEAM ( #4356) MATERIAL 14 GAGE STEEL YIELD ASTM A570, Fy= 55.000 PSI NOTES: USE @ ALL UNARCO BEAM LOCATIONS TYP. 40" 24" 24" 192" 24" 24" 24" 24" get TYPE 16 U20 SELECTIVE RACK 144" 1B FRONT VIEW 192" 5 140" TYPE 16TU SELECTIVE RACK 144" FRONT VIEW STORAGE RACK ELEVATIONS TYPE 16MBZ10 SIDE VIEW FRONT VIEW 36 "H' SIDE VIEW 2B CENTER COLUMN Z O co W 0 w z 6725 SOUTH TODD BLVD. T1 WWII A WA AR1 RR cr4OrTURILA SEP 17 2012 JOB NO. M-08021°‘ SHEET P40. SCE 1 OF •• 0 X +cf._ ti.-12c4- SO -0 MI7M,UMWA..pplaMM ,1-01 1. MN III malssimmimmummim CO 6,91,1i4ecr_WI et? 0/2, 1,46H-orA,-.. • -to bwinpicr*k;'47,fri. 1 PRNIat t%gell i414,(#e VWALZ roz, oxir WrkTEF.- /64%15' CM=Elk ti"1140==e• 1Z1 N4t4ri42 14-Aii.Knot4 IL-For f_ear. r2.1) AU- .p1414,00v, oee 1--lrek--e-4-1671-Y-}e. P.-gen-Id-210H i46141 1.4.1.1706A. Ar-Pit 411,12-12.Aisli LAI-6=4.Artil 111*2 6 1 1 121:f rAbIl 5F,,,,Z1--Fir *7i4' sek+lo-rwAr .184444411 40T.0-40g0 14\ .1-11259,,PINci (-- r)(1.15"r. 141_, /Ai-04 4e-LC.4 1(AL-Vt- 14-r- itea /-1 (1) LEGAL DESCRIPTION • Lot 6 together with the north 197.07 feet of Lot of the Plat of Southcenter South Industrial Park as recorded in volume 97 of Plats, pages 22, 23,'24 an 25, records of King county, Washington. Situate in the county of Ring, state of Washington. 1. General Contractor shall verify all dimensions and building conditions before commencing work. 2. General Contractor shall coordinate with his Subs all bases, curbs and access openings as required for mechanical and electrical equipment. 3. Chamfer all corners on exposed concrete walls. All work shall conform with applicable codes and regulations. 5. See mechanical shop drawings for location and size of roof openings ' for mechanical equipment. Ventilation per the 1985 Uniform. Building Code. 6. Chemical fire extinguishers N.I.C. (Not In Contract). 7. All stud walls and partitions, including furred spaces, shall be fire stopped per code. 8. General Contractor shall furnish and install approved protective pipe guards around F.I. valves, Fire Department connections, electrical transformers and gas meters. 9. All doors, including exits, shall be marked per OSHA standards. 10. Exit door hardware shall conform to U.B.C. Section 3303(C). 11.- Complete fire alarms, hose stations, sprinklers and extingnisher.layoutt _ shall be submitted-per separate permit and approval of-ihshington Survey and Rating Bureau, Factory Mutual, Kemper Insurance Co.-(Durlon Inlenteldt (312)559-3943, to be contacted prior to bidding), and tOe gOverning-Fire Department. Fire lanes, hydrant lOcattons and protecttVe devices 4ha11 be submitted Concurrently for required approvals. • 12 Mechanical and electrical systems;-inclUding exterior surface and,iiih- . -grade improvements shall- be subMitted for separate permit. SP 905 r : - 4- 'KO teeetlifklW tINS950,11t40 oks/e-4-4ue- 461,111-1 HEW 424tiVe44.1AY 4fte- 44-1Y Pr 11.1g40-11LA yrAt419.6 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 4 2O13 City of 'Tukwila BUILDING DIVISION W. Wm GRAINGER SOUTHCENTER SOUTH INDUSTRIAL PARK TUKWILA WASHINGTON &LA 11.194-v1; 1 N air-i L 0,1m AJLEA. 2.tpwIL4211-40-AletA, fgv,f. Anwr164-i .140W-e-HOW;E.; 47h,451‘12. 17,9)0r0 .01/...R.: PA4to0 1-0-AL A4A: 490,1A2 NAif-V-ioue/aff1a.11-ALs-5 I-1 1,re--8-1141,_~ a&e.i,447,41-4G1. IV -2. to. frie.-41-"e114.'. ta4.. 1. L42 ' 5.0 fA71%! 141I-41.7 I4141.1 6 C.O12e- = 1,106, LI Vt. COVe- - 74, PROJECT NO: Ic2 - '2404: REVISIONS: -t-ld 7.2.10 A\ r•vmi W.W. GRAINGER •SHEET NO ADDITIONS / ALTERATIONS SOUTHCENTER S. INDUSTRIAL PARK Alm I TUKWILA -WASHINGTON DATE: i4Tt ALFRED CROONQUIST ARCHITECTS ONE UNION SQUARE BUILDING SUITE 3404 SEATTLE, WASHINGTON 98101 E201:13882051:10 OF 22' -1 1/4" -}- 47' -5 1/4" 50' -0" 50' -0" 48' -7 1/2" UM ME - -- "MI NM - NM ME 51' -11 1/4" 47'-2 3/4" 16U41 ' 16U41 6U41 16U41 16U41 16U41 16U41 16U41 16U41 16U41 16U41 16U41 16U41 16U41 16U41 16U41 16U41 16U41 16U41 16U41 52" DEEP 52" DEEP 53" DEEP 52" DEEP 52" DEEP 52" DEEP 52' DEEP 52" DEEP 52t DEEP 52" DEEP 52' DEEP 52" DEEP 52" DEEP 52" DEEP 52" DEEP 52" DEEP 52" DEEP 52" DEEP 52" DEEP ! 52" DEEP i', FRAME FRAME FRAME FRAME FRAME FRAME FRAME FRAME FRAME FRAME FRAME FRAME FRAME FRAME I, FRAME FRAME FRAME FRAME FRAME FRAME - r - — — — — — — - - - NEI L Ir PHASE -I r L r r � L -- 16020 16U20 16U20 16U20 16U20 16U20 T 16TU 16U20 16U20 16U20 I) 16U20 1 9 10 PHASE -VI 18 SPf■CERS .,: f 12 4 . t .. w F • 312 ,. 2 . €) 4 124-11.2U1. 11 12 13 14 T 15 16 17 18 19 -- -- 1 16U20 1671 1 jJ1�, 16020 16U20 16U20 I) 16U20 1 REPLACE END FRAMES & COLUMN PROTECTORS TYP. FOR ALL HIGHLIGHTED FRAMES (SEE ELEVATION CONFIGURATIONS DETAILS) 1 CO N N; N CO! N NI -- N co CNI 16U20 16U20 16112 16U20 16020 16U20 16U20 16U20 U L6U20 16U20 16U20 Of _, �i U) CO I -- IN N ry ; I IN 16U20 16U20 16U20 16U20 16U20 Id N =N C NI 1 1 1 AL_ 16U20 16U20 16U20 16U20 16020 16U20 16U20 16020 16U 16U20 16U20 16U20 16U20 -- L 1 'r L -- 16U20 16T i II 16MBZ10 J 1 ... Ir L r 1 1' 1C74 11 16MBZ10 am on - -- MBZ10 16MBZ10 16MBZ10 rn 0) 0 i rn CN CL I Z-1 O = RZ 1 1-6 MB-Z-1-0 16U20 6T` . I I11 16U20 16U20 16U20 16U20 16U20 16U20 16U20 16MBZ10 1 • MBZ10 ( 16MBZ10 I 16MBZ10 16MBZ10 16U20 16U20 16U20 16U20 16U20 16U20 16U20 1 1 16U20 t 161:,7 I; 16MBZ10 1 1 1 1 1 MBZ10 REPLACE END FRAMES TYP. FOR ALL HIGHUGH (SEE ELEVATION CONFI 16 V 20 .15 i j 16U20 161521 15U20 I 16U20 .1121 16 U20 1h, r,T 1 1 1 16U20 ISTING END RACKS TO BE REMOVED THIS SIDE ONLY. NOTE: NEW ROW LOCATIONS. SEE DIM'S SHOW. DO NOT USE SAME ROW LOCATIONS. REPLACE END FRAMES & COLUMN PROTECTORS TYP. FOR ALL HIGHLIGHTED FRAMES (SEE ELEVATION CONFIGURATIONS DETAILS) 16MBZ10 COLUMN PROTECTORS y► FRAMES RATIONS DETAILS) MBZ10 16MBZ10 16MBZ10 16MBZ10 0 1 16MBZ10 16MBZ10 16MBZ10 16MBZ10 PHASE -III 1 1 i Is) co ::: I I() 1.0 CO 1 r) CI I� PHASE -II Oh o ° 11 16U20 16020 1602( o — — - — - - — — REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 4 2013 1 1 _- : • ;j} `0I !�'I 001 i 3 "� Ifs CO L ! { �� i� OI C I CC7 ;o 0, . :: I ,,-: 10 f- It- I , 00' i (0! i0 (D 1 ? :'In O;;-! O O (0 CO' I0 Oi City of Tukwila BUILDING DIVISION 1 1 t O O M O ro 0 co, °- 1 1 \-DO NOT REPLACE FRAMES TYP. FOR ALL FRAMES THIS END 1 1 1 1 REPLACE END FRAMES & COLUMN PROTECTORS TYP. FOR ALL HIGHUGHTED FRAMES (SEE ELEVATION CONFIGURATIONS DETAILS) 1 1 1 1 1 PHASE -IV 1 1 O O to to (O (D Ng ,ti.s- N IO0 0 -r O0 Si r REPLACE END FRAMES & COLUMN PR TECTORS TYP. ALL ROW ENDS & TUNNELS I (SEE ELEVATION CONFIGURATIONS DETAILS) MANIFEST SYSTEM - - — — PHASE -V UM NM 1 1 1 1 1 - - - — - - MI — — PHASE -VIII NEW WILL CALL OUTBOUND DOCKS INBOUND DOCKS CNI CO 16HC14 16HC14 16HC14 2x33” 2x33" 2x33" 16HC14 16HC14 16HC14 16HC14 1 16HC14 2x33" 2x33" #2 #3 #4 #5 #6 Lt CNI 2 x 33" 2 x 33" 2 x 33" SPRINKLER NOTE: 16' UP ! 16' UP 16' UP 16' UP 1. THE SOUTHERN SYSTEM IN THE MAIN BUILDING IS ARRANGED AS A CENTER -END TREE, USING LARGE - ORIFICE, 286F RATED HEADS. SPACING BETWEEN HEADS ON A BRANCH LINE IS 9 FT. 3 IN. SPACING BETWEEN BRANCH LINES IS 10 FT. THERE ARE TEN HEADS PER BRANCH LINE, FIVE ON EACH SIDE. THE FEED MAIN IS 4 IN. CONNECTING TO A 6 IN. RISER. THE SPRINKLER SYSTEM WAS ANALYZED AND CAN PROVIDE A 0.36 GPM /SQ. FT. DENSITY OVER THE MOST REMOTE 2,500 SQ. Ft AREA, PLUS 500 GPM FOR HOSE STREAMS. 8' HI- DENSITY - — — — ELECTRICAL CHARGERS 2. THE NORTHERN SYSTEM IN THE MAIN BUILDING IS ARRANGED AS A LOOP, USING LARGE - ORIFICE, 286F RATED HEADS. SPACING BETWEEN HEADS ON A BRANCH LINE IS 9 Ft SPACING BETWEEN BRANCH LINES IS 10 FT. THERE ARE NINE HEADS PER BRANCH UNE, FIVE AND FOUR ON EACH SIDE. THE FEED MAIN IS 4 IN. CONNECTING TO A 6 IN. RISER. THE SPRINKLER SYSTEM WAS ANALYZED AND CAN PROVIDE A 0.48 GPM /SQ. FT • 3' THE MOST REM 2500 SQ. FT. AREA, PLUS 500 GPM FOR HOSE STREAMS. SYMBOL KEY: I.7b. •I 7 „2:t1A *O. .t,.I ►� 2 I q,. q: , ,k • : I t. CENED 1 3 0 5 NOV 0 9 2012 DRAWING REVISIONS DESCRIPTION CUSTOMER LOCATION GRAINGER DRAWING TITLE PLAN VIEW AND ELEVATION DETAILS TUKWILA, WA JOB NUMBER 42164 SHEET SLO1 SCALE (D -SIZE) 1/8 " =1'-0 DRAWN BY 09/05/12 • • — I 1 r r 1 1 1 PHASE -IV 1 1 O O to to (O (D Ng ,ti.s- N IO0 0 -r O0 Si r REPLACE END FRAMES & COLUMN PR TECTORS TYP. ALL ROW ENDS & TUNNELS I (SEE ELEVATION CONFIGURATIONS DETAILS) MANIFEST SYSTEM - - — — PHASE -V UM NM 1 1 1 1 1 - - - — - - MI — — PHASE -VIII NEW WILL CALL OUTBOUND DOCKS INBOUND DOCKS CNI CO 16HC14 16HC14 16HC14 2x33” 2x33" 2x33" 16HC14 16HC14 16HC14 16HC14 1 16HC14 2x33" 2x33" #2 #3 #4 #5 #6 Lt CNI 2 x 33" 2 x 33" 2 x 33" SPRINKLER NOTE: 16' UP ! 16' UP 16' UP 16' UP 1. THE SOUTHERN SYSTEM IN THE MAIN BUILDING IS ARRANGED AS A CENTER -END TREE, USING LARGE - ORIFICE, 286F RATED HEADS. SPACING BETWEEN HEADS ON A BRANCH LINE IS 9 FT. 3 IN. SPACING BETWEEN BRANCH LINES IS 10 FT. THERE ARE TEN HEADS PER BRANCH LINE, FIVE ON EACH SIDE. THE FEED MAIN IS 4 IN. CONNECTING TO A 6 IN. RISER. THE SPRINKLER SYSTEM WAS ANALYZED AND CAN PROVIDE A 0.36 GPM /SQ. FT. DENSITY OVER THE MOST REMOTE 2,500 SQ. Ft AREA, PLUS 500 GPM FOR HOSE STREAMS. 8' HI- DENSITY - — — — ELECTRICAL CHARGERS 2. THE NORTHERN SYSTEM IN THE MAIN BUILDING IS ARRANGED AS A LOOP, USING LARGE - ORIFICE, 286F RATED HEADS. SPACING BETWEEN HEADS ON A BRANCH LINE IS 9 Ft SPACING BETWEEN BRANCH LINES IS 10 FT. THERE ARE NINE HEADS PER BRANCH UNE, FIVE AND FOUR ON EACH SIDE. THE FEED MAIN IS 4 IN. CONNECTING TO A 6 IN. RISER. THE SPRINKLER SYSTEM WAS ANALYZED AND CAN PROVIDE A 0.48 GPM /SQ. FT • 3' THE MOST REM 2500 SQ. FT. AREA, PLUS 500 GPM FOR HOSE STREAMS. SYMBOL KEY: I.7b. •I 7 „2:t1A *O. .t,.I ►� 2 I q,. q: , ,k • : I t. CENED 1 3 0 5 NOV 0 9 2012 DRAWING REVISIONS DESCRIPTION CUSTOMER LOCATION GRAINGER DRAWING TITLE PLAN VIEW AND ELEVATION DETAILS TUKWILA, WA JOB NUMBER 42164 SHEET SLO1 SCALE (D -SIZE) 1/8 " =1'-0 DRAWN BY 09/05/12 ( r I r-I 00 1 N I-- - N CO CO 00 - N N CO C F d- N N N 0 N 1 CO (0 r1 E-+ co �-I (0 1 5 rr) d- CN N CN N 00 O H_D E-� CSC c-i 5 co CO r' CO 5 CR 1 t -� CS0 ri CO 71- d" c° D D 0 (0 r-i RI DRAWING REVISIONS DESCRIPTION CO 5 N d- d- O ° (0 CO 0 N 00 c- if) — rr) 0) 0 O d' CO Ln N CO 5 5 ` CO 5 E-+ CO 5 E-� CO N CN 0) O CO LCD e--I O LCD r� w r' O CO O CO r! O O LO CO CO 5 LC) N5) F_ E-1 CSC E CO •r-i O O 0 LCD LCD 0 o o CO CO rn O i) (O 0 0 rr) 0 0 O N) C0 PHASE —V .1--1 e-1 O LCD CO 5' Ln 0 O LCD CO O CO O 00 N C° N O CO LCD O LCD Co N 5' N CN CN O N O 1.0 CO O CO O CO (fl 5' E-I C0 00 CO r N 0 r 0 CN CO 1 O CO 0 Lo CO N CO rr) d- N N N N N 0) 0 ("N CO CO 5' CO r' (o rI CO rl F -� E-I r- 00 o CO 5, O 1 E-1 CO c-i O ICJ C0 5' O LCD CO r-i O CO 5' CO h- 00 LC) CO rr) CT) 0 O N rr) N N 0) CO CO C\2 CO CO C\2 co CO CO \2 CO 5, C\2 CO CO r' E-1 CO r-i 5, O 5' (N 71- d- CO CO 5 L. = J in CO 0 0 0 0 O Ln C° N O Lf) CO E-1 CO •r-i C\2 CO CO O 5' O 5' 0 • 1 Ln rr) 0) O 0 N) 0 REPLACE END FRAMES & COLUMN PRQTECTORS TYP. ALL ROW ENDS & TUNNELS (SEE ELEVATION CONFIGURATIONS DET TLS) I. RR 1111 IN MI 00 N C° N N N O N CO CO 0 00 0 0 O d 0 5I CO 5' 5, O CO LCD CO N N 5, CO CO E'{ CO 5' rr) N N (N CN N C\2 CO CO 5' C\2 CO CO 5' C\2 Co r-1 C\2 00 CO ri C\2 W CO C\2 CO CD C\2 CO 5' N-� CO C\2 CO CO 00 — Ln N) d C\2 CO CO r-i h -� E-� CO 5, CO 5' 771-! co e-1 5' co N LD N �-1 CO 5' 5' CO E-� C0 5' (C) 5' CO 5' CO 5' CO 5' 5, CO r' 5' CO r, N -4 CO r-I LCD C\2 r-I CO 5' C\2 5' 03 0 (O L) CO 0 0 co 5' LCD C\1 5, CO r-i LCD C\2 CC) N 5, CO 5' 1 N 0 0 O I\ CO N O V) N 1 (74 1 1 1 0) LC) 1 1 1 74- O 5' Ln O 5' 7-1f" O 5, CCD CO 7t- CO CO in 3" 96" o) 3" TYPE: 16U41 ELEVATION DETAIL FRONT VIEW 33" 12 "/30" 33" TYPICAL ELEVATION DETAIL SIDE VIEW CN Q) 3" 1 in n LO 96" m 3" TYPE: 16U50 ELEVATION DETAIL FRONT VIEW 3" in 0 96" o) 3" TYPE: 16U101 ELEVATION DETAIL FRONT VIEW 3" 96" 0) 3" TYPE: 16U179 ELEVATION DETAIL FRONT VIEW 1/2" DIA. X 4-1/2" LG. ANCHOR MINIMUM EMBEDMENT OF 3 -1/4" (2) REQ'D PER END OF AISLE GUARD 1/2" DIA. X 4-1/2" LG. ANCHOR MINIMUM EMBEDMENT OF 3 -1/4" (2) REQ'D PER END OF AISLE GUARD LEFT TOP LEFT FRONT 3" CO to 96" TYPE- 16TU ELEVATION DETAIL FRONT VIEW - TUNNEL BAY RIGHT TOP COLUMN PROTECTOR ANCHOR DETAIL (TYP. ALL LOCATIONS) b13os RIGHT FRONT REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 41013 City of Tukwilr BUILDING biVis RECEIVED CITY OF TUKVTI....A NOV 0 9 2012 DATE BY NOTES: 1.) DEVIATIONS FROM THE DESIGNED RACK LIMITATIONS OR CONFIGURATIONS MAY IMPAIR THE SAFETY OF THE RACK INSTALLATION. 2.) ALL RACK IS DESIGNED IN ACCORDANCE WITH ANSI MH16.1 - 2004 RMI SPECIFICATIONS. 3.) ALL VERTICAL DIMENSIONS ARE TAKEN FROM TOP OF FOOT PLATE. Wynnght 2500 YORK ROAD ELK GROVE, IL 60007 1F1.: (847) 595 -9400 FAX (847)595 -2126 THIS DOCUMENT IS CONFIDENTIAL PROPRIETARY INFORMATION OF WYNRIGHT AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS SPECIFICALLY FURNISHED WITHOUT THE PRIOR WRITTEN CONSENT OF WYNRIGHT. CUSTOMER LOCATION GRAINGER TUKWILA, WA DRAWING TITLE JOB NUMBER SHEET PLAN VIEW AND ELEVATION DETAILS PHASE: V 42164 SLO2 SCALE (D-SIZE) DRAWN BY DATE REV. CDM - - - IS L PHASE 1 E I I L 1 1 Ir L 1 1 L 1 REMOVE —r - - IM w RS _Th 16U20 16U20 16U20 16U20 16U20 16U20 16U20 16U20 16U20 16U20 16U20 SAME SAME SAME 16U20 SAME SAME SAME SAME SAME 16TU 16U20 SAME 16U20 16U20 16U20 J — I REPLACE END FRAMES & COLUMN PROTECTORS TYP. FOR ALL HIGHLIGHTED FRAMES (SEE ELEVATION CONFIGURATIONS DETAILS) SAME :i6TU::16MBz10 o 16U20 16U20 16U20 16U20 16U20 16U20 L' 16U20 16U20 16TU f 16U20 SAME 16U20 16U20 16U20 -- STET- 16U20- 16 16U20 16_112a 16U20 16U20 16U20 16U20 16TU 1AU20 -SAME I 1.6JZ12.0 1.611211______ 16_1_120 J -02-0 J 1, 1 • Ln SAME I SAME in SAME SAME -L i::16U20 SAME 16U20 SAME 16U20 16U20 16U20 SAME 16U20 SAME 16U20 1 SAME 16U20 SAME 16TU 16U20 J 16U20 16 T U 16U20 i r 16MBZ10 J 16U20 16U20 16U20 16U20 In 16U20 16U20 I o) _--- SAME III -------------------------------------------- -SAME - - - - --41. -------- �I - - -- cQ IIN IS SAME mow I- - IS IS NM IN SAME SAME SAME 16U20 SAME SAME SAME SAME SAME :i6TU::16MBz10 16MBZ10 16MBZ10 16MBZ10 L' SAME SAME SAME STET- SAME- ±6m I r 1-6-MB-Z1- 0 16 Z10 1`6 BZ10 16 Z10 +6-U-2-0- -SAME J 1 1 J 1, 1 • Ln SAME SAME SAME 16U20 SAME SAME 1 SAME SAME r � T! ' 1 LVs � � � 16MBZ10 ! L 1 MBZ10 16MBZ10 16MBZ10 J -r 1 16U20 16U20 16U20 16U20 16U20 16U20 16U20 16TU II II 1 16MBZ10 1 MBZ10 16MBZ10 16MBZ10 REPLACE END FRAMES N_ TYP. FOR ALL HIGHLIGH (SEE ELEVATION CONFIG COLUMN PROTECTORS D FRAMES RATIONS DETAILS) 16U20 -L 16U20 16U20 16U20 16U20 16U20 16U20 16U20 16TU J I I 16MBZ10 1 16MBZ10 16MBZ10 16MBZ10 1 J 1 . 1 II 16� 1 —16I 1 -602-0 16U20 16020 f6 0 116U20 11672 -0 16 i�LF 16MBZ10 1 MBZ10 16MBZ10 16MBZ10 DO NOT o o REPLAC (SE END FRAMES & COLUMN TYP. FOR ALL HIGHLIGHTED ELEVATION CONFIGURATIONS 1 I t— EXISTING END RACKS TO BE REMOVED THIS SIDE ONLY. NOTE: NEW ROW oEA11ON ROW LOCATIONS. I'OWN. . PROTECTORS FRAMES DETAILS) i INI N. PHASE-III .. .. •■••7 = N. 1. PHASE-II 16U20 16U20 16U20 /! T 161J20 16TU 16U20 16U20 16U20 1 1 16U20 • 16U20 16U20 16U20 16U20 161 U 16U20 16U20 16U20 16U20 J SAME SAME SAME -SAME SAME ��' SAME SAME S� SAME SAME � SAME sAM SAME SAME DO NOT REPLACE FRAMES TYP. FOR ALL FRAMES THIS END REPLACE END FRAMES & COLUMN PROTECTORS TYP. FOR ALL HIGHLIGHTED FRAMES (SEE ELEVATION CONFIGURATIONS DETAILS) SAME SAME SAME SAME 1 SAME SAM- SAME -SAME SAME SAME SAME SAME , . SAME S� SAME -S E SAME SAME sAM SAME SAME DO NOT REPLACE FRAMES TYP. FOR ALL FRAMES THIS END REPLACE END FRAMES & COLUMN PROTECTORS TYP. FOR ALL HIGHLIGHTED FRAMES (SEE ELEVATION CONFIGURATIONS DETAILS) SAME SAME SAME SAME 1 SAME SAME SAME SAME SAME SAME SAME SAME , . SAME SAME SAME SAME SAME DO NOT REPLACE FRAMES TYP. FOR ALL FRAMES THIS END REPLACE END FRAMES & COLUMN PROTECTORS TYP. FOR ALL HIGHLIGHTED FRAMES (SEE ELEVATION CONFIGURATIONS DETAILS) SAME SAME SAME SAME 1 SAME SAME SAME SAME r: SAME SAME SAME SAME SAME SAME --•1, SAME SAME SAME S AIV SAME SAME SAME S SAME } -- - !MINH - - MR 1M 1 1 1 1 1 1 1 1 1 1 1 1 PHASE -IV 3" CO r7 96" Q N 3" TYPE: 16TU ELEVATION DETAIL FRONT VIEW - TUNNEL BAY 3" 1 1 1 1 1 1 1 1 1 1 i+) CD N 96" 0) 3" TYPE: 16U20 ELEVATION DETAIL FRONT VIEW REVIEWED FOR CODAPPROVED COMPLIANCE JAN 042013 City of Tukwila BUILDING DIVISION 3" CONCRETE ANCHOR 1/2" DIA. x 4-1/2" HILTI 12 TYP. FOOTPLATE DETAIL (WITH NEW FOOT PLATE BASE WELD SHOWN) 12 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10-1/2" CLEAR 10-1/2" CLEAR 10 -1/2" CLEAR 12" CLEAR 12 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 12" CLEAR 1 12 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 12 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 18" CLEAR 18" CLEAR 144" o) 3" 33" 12 "/30" 33" TYPE: 16MBZ10 TYPICAL ELEVATION DETAT �y` ^�,;I fr. ELEVATI ON DETAIL o FRONT VIEW NOV 0 9 2012 SIDE VIE. s rn DRAWING REVISIONS REV DESCRIPTION DATE BY NOTES: 1.) DEVIATIONS FROM THE DESIGNED RACK LIMITATIONS OR CONFIGURATIONS MAY IMPAIR THE SAFETY OF THE RACK INSTALLATION. 2.) ALL RACK IS DESIGNED IN ACCORDANCE WITH ANSI MH16.1 - 2004 RMI SPECIFICATIONS. 3.) ALL VERTICAL DIMENSIONS ARE TAKEN FROM TOP OF FOOT PLATE. Wynright 2500 YORK ROAD ELK GROVE, IL 60007 1EL: (847) 595 -9400 FAX: (847)595 -2126 CUSTOMER LOCATION GRAINGER TUKWILA, WA DRAWING TITLE JOB NUMBER SHEET THIS DOCUMENT IS CONRCENTULL PROPRETARY WFORMATION OF WYNRIGHT AND SHALL NOT BE USED FOR ANY PURPOSE OTFER THAN FOR MHCH IT IS SPECIFICALLY FURNISHED NM'MOUT THE PRIOR MRITTEN CONSENT OF WYMiIOHT. PLAN VIEW AND ELEVATION DETAILS PHASES II, III, AND IV 42164 SLO3 SCALE BY CALIF (D -SIZE) DRAWN B 1/8 " =1'-0 CDM DATE REV. 09/07/12 SAME SAME SAME SAME --•1, SAME SAME SAME SAME } -- - !MINH - - MR 1M 1 1 1 1 1 1 1 1 1 1 1 1 PHASE -IV 3" CO r7 96" Q N 3" TYPE: 16TU ELEVATION DETAIL FRONT VIEW - TUNNEL BAY 3" 1 1 1 1 1 1 1 1 1 1 i+) CD N 96" 0) 3" TYPE: 16U20 ELEVATION DETAIL FRONT VIEW REVIEWED FOR CODAPPROVED COMPLIANCE JAN 042013 City of Tukwila BUILDING DIVISION 3" CONCRETE ANCHOR 1/2" DIA. x 4-1/2" HILTI 12 TYP. FOOTPLATE DETAIL (WITH NEW FOOT PLATE BASE WELD SHOWN) 12 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10-1/2" CLEAR 10-1/2" CLEAR 10 -1/2" CLEAR 12" CLEAR 12 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 12" CLEAR 1 12 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 12 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 18" CLEAR 18" CLEAR 144" o) 3" 33" 12 "/30" 33" TYPE: 16MBZ10 TYPICAL ELEVATION DETAT �y` ^�,;I fr. ELEVATI ON DETAIL o FRONT VIEW NOV 0 9 2012 SIDE VIE. s rn DRAWING REVISIONS REV DESCRIPTION DATE BY NOTES: 1.) DEVIATIONS FROM THE DESIGNED RACK LIMITATIONS OR CONFIGURATIONS MAY IMPAIR THE SAFETY OF THE RACK INSTALLATION. 2.) ALL RACK IS DESIGNED IN ACCORDANCE WITH ANSI MH16.1 - 2004 RMI SPECIFICATIONS. 3.) ALL VERTICAL DIMENSIONS ARE TAKEN FROM TOP OF FOOT PLATE. Wynright 2500 YORK ROAD ELK GROVE, IL 60007 1EL: (847) 595 -9400 FAX: (847)595 -2126 CUSTOMER LOCATION GRAINGER TUKWILA, WA DRAWING TITLE JOB NUMBER SHEET THIS DOCUMENT IS CONRCENTULL PROPRETARY WFORMATION OF WYNRIGHT AND SHALL NOT BE USED FOR ANY PURPOSE OTFER THAN FOR MHCH IT IS SPECIFICALLY FURNISHED NM'MOUT THE PRIOR MRITTEN CONSENT OF WYMiIOHT. PLAN VIEW AND ELEVATION DETAILS PHASES II, III, AND IV 42164 SLO3 SCALE BY CALIF (D -SIZE) DRAWN B 1/8 " =1'-0 CDM DATE REV. 09/07/12 LO N CD A-- LO CO r Lf) N m T L() N 1 C0 LO N CO LC) N CD LO N_ CD LC) D (0 LC) N T." LO N m N J m Lt) N CO LC) N_ A-- LO N D CD N (0 M X N r) M X N C) M X N CO CO x N C ) CO X N CO CO X N CO CO X N CO X N M CO x N CO CO X N CD M x N M c) X N M CO X N N CD -CD 1 i T t -CD ro PHASE -VII DRAWING REVISIONS 4 0) N -5 1/4" 50' -0" 50' -0" 48'-7 1/2" 16U41 52" DEEP FRAME 1 1 - - 16U41 16U41 16U41 16U41 16U41 16U41 16U41 13U41 16U41 16U41 52" DEEP 52" DEEP 52" DEEP 52" DEEP 52" DEEP 52" DEEP - 52" DEEP 52T DEEP 52" DEEP 52" DEEP FRAME RAME FRAME FRAME FRAME FRAME FRAME FAME FRAME FRAME 16U41 52" DEEP FRAME -h- f — - MB MO WM - - - 7111T IN - — — 16U41 16U47 16U41 52" DEEP 52" DEEP 52" DEEP FRAME FRAME 4 FRAME `PHASE -VIII NI ME 16HC14 16HC14 16HC14 16HC14 16HC14 16HC14 16HC14 2 x 33" 2 x 33" 2 x 33" 2 x 33" 2 x 33" 2 x 33" 2 x 33" 1 E -IV 16' UP CO i Iv \ I F EST SYSTEM PHASE -IX UP UP UP UP UP UP UP 1 16HC14 1 1 2 x 33" UP 8' HI- DENSITY J. — - 3" 101 III 1 AM If) L) 96" 3" TYPE: 16U41 ELEVATION DETAIL FRONT VIEW 33" 12 "/30" 33" TYPICAL ELEVATION DETAIL SIDE VIEW N 0) 3" 3" ( MN WO In 96" C7) 3" TYPE: 16U50 ELEVATION DETAIL FRONT VIEW (0 M CO r) 96" 1 3" TYPE: 16TU ELEVATION DETAIL FRONT VIEW — TUNNEL BAY 3" 3" - - - - - - — 16U41 52" DEEP FRAME 16U41 16U41 52" DEEP 52" DEEP FRAME FRAME 16U41 52" DEEP FRAME - In 96" C7) 3" TYPE: 16U101 ELEVATION DETAIL FRONT VIEW M CD td- N 96" N O) 3" TYPE: 16U20 ELEVATION DETAIL FRONT VIEW 0 (0 3" HNO11111 Mil IM NW — REVIEWED FOR CODE COMPLIANCE APPROVED JAN 04 2013 City of Tukwila BUILDING DIVISION 3" 16U41 52" DEEI FRAME N) 00 • 96" 0) 3" TYPE: 16U179 ELEVATION DETAIL FRONT VIEW 1 12 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 12" CLEAR 12 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 18" CLEAR 12 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 12" CLEAR 12 -1/2" CLEAR 10 -1/2" CLEAR 10 -1/2" CLEAR 18" CLEAR l 12 1124 2U12, �9 10 PHASE -VI CO N 144" 0) 3" TYPE: 16MBZ10 ELEVATION DETAIL FRONT VIEW 3" CO M CO M 96" O N 3" 3" TYPE: 16TU ELEVATION DETAIL FRONT VIEW — TUNNEL BAY 0) N 96" TYPE: 16U125 ELEVATION DETAIL FRONT VIEW 0) 3" 3" 3" 1 0) CO 0) C0 96" Cr) 3" TYPE: 16U65 ELEVATION DETAIL FRONT VIEW 0) CO 0) CD 96" 0) 3" TYPE: 16U65 ELEVATION DETAIL FRONT VIEW RECEIVED bP3os NOV 0 9 2012 !-r Gyp REV DESCRIPTION DATE BY NOTES: 1.) DEVIATIONS FROM THE DESIGNED RACK LIMITATIONS OR CONFIGURATIONS MAY IMPAIR THE SAFETY OF THE RACK INSTALLATION. 2.) ALL RACK IS DESIGNED IN ACCORDANCE WITH ANSI MI-116.1 — 2004 RMI SPECIFICATIONS. 3.) ALL VERTICAL DIMENSIONS ARE TAKEN FROM TOP OF FOOT PLATE. Wynr.ght 2500 YORK ROAD ELK GROW. IL 60007 1EL• (647) 595 -9400 FAX (847)595 -2126 THAS DOC: A/ENT IS CONFIDENTIAL PROPRIETARY INFORMATION OF WYNRIGHT AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN FOR WENCH IT IS SPECIFICALLY FURNISHED YNTHOUT THE PRIOR WRITTEN CONSENT OF WYNRIGHT. CUSTOMER LOCATION GRAINGER TUKWILA, WA DRAWING TITLE JOB NUMBER SHEET PLAN VIEW AND ELEVATION DETAILS 42164 SLO4 SCALE (D-SIZE) DRAWN BY DATE REV. 1/8"=1'-0 CDM 09/07/12 22' -1 1/4" 47' -5 1/4" L PHASE -I 50' -0" 50' -0" 48' -7 1/2" 161141 - 161141 161141 j 161141 161141 161141 161141 161141 J 161141 161141 161141 161141 52" UP 52" UP 52" UP 52" UP 52" UP 52" UP 52" UP 52" UP 52" UP 52" UP 52" UP 52" UP 16U41 16U41 16U41 16U41 16U41 52" UPrIs i T 1 16U20 16U20 16U20 16U20 16U20 1 16U20 16U20 16TU 16U20 116U20 16U20 16U20 16U20 16TU 16U20 116U20 16U20 16U20 16U41 16U41 16U411 r 1 �I I 16TU 16U20 16U20 _16TU ___ _ _ 161120 161120 16U20 16U20 116U20 16U20 16U20 16U20 ' 16U20 16U20 i 16U20_ _16_U20 16020 16U20 16U20 16U20 16U20 16U20 5 5 , , 5 5 5 5 5 5 5 , , 5 , } , , , , 5 5 h , , 5 5 , 5 5 5 , 5 , , } 5 - - - } j - - , - - - - - - , - , , - , 16U20 16TU 16020 161120_ 16U20 16U20 16U20 16U20 16U20 16020 116020 16U20 16TU 16U20 16U20 0 ap 16U20 16U20 16U20 16U20 O 16U20 16U20 I 1 16U20 lotLC) 16U20 0 21'- 11 16U20 16U20 16U20 1l I 16U20 1 1 16TU 16MBZ10 19MBZ10 16MBZ10 1 I A 61120 16TU 16U20 16TU 16U20 16U20 16U20 1 16U20 16U20 100_x:; 16TU 16U20 16U20 16U20 16U20 16U20 16U20 16U20 16U20 16TU -161120 1131120- 16U20 161120 1611-20 116020 1h1.120- 6U20 -1611T REPLACE END FRAMES & COLUMN PROCTORS TYP. FOR ALL HIGHLIGHTED FRAMES (SEE ELEVATION CONFIGURATIONS DETAILS) O 16U20 16U20 16U20 16U20 16TU 16U20 16U20 16U20 16U20 16U20 16TU 16U20 16U20 16U20 16U20 16U20 16U20 16U20 I I 108' 63.4" CV u) SAME SAME SAME SAME 16TU SAME SAME SAME SAME N L _ in v SAME SAME -SAME I SAME- 16TU SAME - SAME SAME - SAME- SAME SAME SAME SAME 1MTU SAME SAME 1 SAME SAME s, r: LO SAME SAME SAME SAME 1TU SAME SAME SAME SAME SAME SAME SAME SAME 1311 SAME SAME SAME SAME (Ni EiL7 Ln BAIVIE SAME -SAME SAME 1SU SAME SAME ' -SAME SAME - N = SAME SAME SAME SAME 16TU SAME SAME 11 SAME SAME Cr) N LJ 1-1I 1.6'UP 16UP 16MBZ10 16MBZ10 16MBZ10- 16MBZ10 16MBZ10 I.1 16MBZ10 1 MBZ10 16MBZ10 I •A 16MBZ10 16MBZ10 16MBZ10 REPLACE END FRAlqES & COLUMN PgOTE�TORS -TYP. FOR ALL HIGHLIGHTED FRAM (SEE ELEVATION CONFIGURATIONS DETAILS) 16MBZ10 1 f MBZ10 16MBZ10 16MBZ10 LCD 16MBZ10 t10 16MBZ10 co LC) 1-6MBZ10 16MBZ10 16MBZ10 16MBZ10- 51' -11 1/4" N 47' -2 3/4" ' � I 09 10 11 12 13 14 15 150' -O~ — — I N N tttrtl- • (N N • N M 7r' N N N N N CO N r aJ N N N N C,") N N L _ N N Lf) co (D ( D X aI CD • N D CO (D 00 1 — CS) ›R' 0_ • N D I 1 In in (0 CO 1 -49 CD X (Li co • I a). X DI co CO D x p_1 m cu +; I Ln 1 CDco -'84" # ° N� PHASE -III i16HC14 16HC14 16HC14 "16HC14 16HC14 116HC14 16HC14 ,'16HC14 2 x 33" 2 x 33" 302 XSTSCERZ x 33" 2 x 33" 2 x 33" 2 x 33" 302 k33TERs 1UP 'OP UP UP ,UP UP UP SUP 18" SPACERS S 8' HI- DENSITY 18" SPACERS a L r-) Ln - � 41 I C1-1 LCh O Lcn Up c--i LT, w Co MANIFEST SY NEW WILL CALL SPRINKLER NOTE: PHASE -II REVIEWED FOR CODE PROVED OMPLIANCE AP JAN 04 2013 1 ity of Tukwila DING DIVISION OUTBOUND DOCKS CO O d O 1 INBOUND DOCKS #3 #4 #5 #6 #7 1. THE SOUTHERN SYSTEM IN THE MAIN BUILDING IS ARRANGED AS A CENTER -END TREE, USING LARGE- ORIFICE, 286 °F RATED HEADS. SPACING BETWEEN HEADS ON A BRANCH LINE IS 9 FT. 3 IN. SPACING BETWEEN BRANCH LINES IS 10 FT. THERE ARE TEN HEADS PER BRANCH LINE, FIVE ON EACH SIDE. THE FEED MAIN IS 4 IN. CONNECTING TO A 6 IN. RISER. THE SPRINKLER SYSTEM WAS ANALYZED AND CAN PROVIDE A 0.36 GPM /SQ. FT. DENSITY OVER THE MOST REMOTE 2,500 SQ. FT. AREA, PLUS 500 GPM FOR HOSE STREAMS. 2. THE NORTHERN SYSTEM IN THE MAIN BUILDING IS ARRANGED AS A LOOP, USING LARGE- ORIFICE, 286 °F RATED HEADS. SPACING BETWEEN HEADS ON A BRANCH LINE IS 9 FT. SPACING BETWEEN BRANCH LINES IS 10 FT. THERE ARE NINE HEADS PER BRANCH LINE, FIVE AND FOUR ON EACH SIDE. THE FEED MAIN IS 4 IN. CONNECTING TO A 6 IN. RISER. THE SPRINKLER SYSTEM WAS ANALYZED AND CAN PROVIDE A 0.48 GPM /SQ. FT. DENSITY OVER THE MOST REMOTE 2,500 SQ. FT. AREA, PLUS 500 GPM FOR HOSE STREAMS. SYMBOL KEY: - DENOTES EMERGENCY LIGHTS LOCATION - DENOTES EMERGENCY EXIT SIGN LOCATION CM 0 ` CO O 0 0 O M a O 0 O t0 O ELECTRICAL O ;- am o O CO O O 0 0 Cr) cItt O O O N O CHARGERS tttct- DRAWING REVISIONS DESCRIPTION DATE BY Luminaire Schedule Symbol Qty Label Arrangement Total Lamp Lumens LLF Description 64 F1 SINGLE 2748 0.700 IB 454 SEA -TAC ELECTRIC, INC. C O M M E R C I A L • I N U I J T H I A L Wynr.ght 2500 YOWL ROAD ELK GROVE, IL 60007 1EL• (847) 595 -9100 FAX: (84'7)595• -2126 7X15 DOc** 1T I5 DONRDEN nAL PROPRIETARY OAFORMA71ON OF Wfll GHT AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN FOR MAN IT IS SPEt7FlCN.LY FURNISHED MlHOUT THE PRIOR WRITTEN CONSENT OF WYNRIGHT. CUSTOMER co co co • 1 X D-1 co ✓ CV D _ CV M, 1 r M X d.I • CV: D 1' -4" 0 O LC) _ cq - co X', Q. co _ I N C�) r c) X IS) _ 1 O C 1 M • D �� O CO N 1 (.0 - c94 Q-1 a r. " Di o L7 cry I'— - D X0_1, 0)' RE0E!VED CITY OF T!. :`.`,';`. NOV 0 9 2012 EI°. <1i /I1 LOCATION GRAINGER TUKWILA, WA DRAWING TITLE JOB NUMBER SHEET EMERGENCY LIGHTING AND EGRESS PLAN SLO5 SCALE (D -SIZE) DRAWN BY DATE REV. 1 /8"=1 CDM 11 /06/12 GRAINGER TENANT LIGHTING IMPROVEMENTS Code Summary CODE SUMMARY: - WASHINGTON STATE BUILDING CODE - WASHINGTON STATE AMENDMENTS - 2009 INTERNATIONAL BUILDING CODE - 2009 INTERNATIONAL MECHANICAL CODE - 2009 INTERNATIONAL FIRE CODE - 200e UNIFORM PLUMBING CODE - 2009 WASHINGTON STATE ENERGY CODE - 2009 WASHINGTON STATE VENTILATION AND INDOOR QUALITY CODE FULLY SPRINKLED BUILDING - TO BE SUBMITTED UNDER SEPARATE PERMIT. MECHANICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT ELECTRICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT PLUMBING DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT. TENANT IMPROVEMENT - TO BE SUBMITTED UNDER SEPARATE PERMIT. THIS WORK AND ASSOCIATED PERMIT REPRESENTS THE TENANTS RENOVATION TO EXISTING EMERGENCY LIGHTING SYSTEM. LEGAL DESCRIPTION: SOUTH CENTER SOUTH INDUSTRIAL PARK LOT 6 TGWN 191.0 FT. LOT 7 AKA BOUNDARY LINE ADJ1 -1a. TENANT ADDRESS: 6125 SOUTH TODD BOULEVARD TUKWILA, WA 98188 TAX PARCEL NUMBER: T88- 890 -0060 ZONING USE: TUC - TUKWILA URBAN CENTER TENANT IMPROVEMENT SUMMARY: TOTAL SQUARE FOOTAGE: 55,650 SF IN AREA OF WORK OCCUPANCY GROUP: GRAINGER'S MIXED USE - MERCHANTILE/WAREHOUSE= M /S2 AREA OF WORK IS IN WAREHOUSE ONLY. OCCUPANCY LOAD (TABLE 1004.1.1): OCCUPANCY LOAD FACTOR - WAREHOUSE AREA: 55,650 SF 1 500 : 112 OCCUPANTS EGRESS REQUIREMENTS: PER TABLE 1005.1 112 OCCUPANTS X 0.2 = 22.4 INCHES REQUIRED EXIT WIDTH. EXISTING WAREHOUSE SPACE PROVIDES (4) EXITS A TOTAL WIDTH OF 136" THEREFORE MEETS CODE REQUIREMENTS. PER TABLE 1021.1.1 OCCUPANT LOADS OF I -500 REQUIRE TIUO EXITS, A TOTAL OF (4) EXITS ARE EXISTING THEREFORE MEETS CODE REQUIREMENTS. MINIMUM CORRIDOR WIDTH OF 44 ": EXISTING CORRIDOR WIDTHS EXCEED REQUIRED MINIMUM, THEREFORE MEETS CODE REQUIREMENTS. TABLE 1016.1 OCCUPANCY S2 MAXIMUM TRAVEL DISTANCE WITH SPRINKLER SYSTEM 15 400 FEET. TRAVEL DISTANCE WITHIN TENANT SPACE IS LESS THAN 400 FEET, THEREFORE MEETS CODE REQUIREMENTS. General Notes I. ALL WORK TO BE PERFORMED IN COMPLIANCE WITI -1 ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK 2. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. 3. THE ARCHITECT WILL HAVE A REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SITE VISITS TO OBSERVE THE CONSTRUCTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR N RESOLVING VARIATIONS N THE EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL KNOWN CONDITIONS, BUT IT IS ANTICIPATED THAT HIDDEN CONDITIONS WILL BE ENCOUNTERED DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGES. 4. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LNES TRUE, LEVEL, PLUMB AND SQUARE. 5. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. POSTED DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. 6. ALL ATTACHMENTS, CONNECTIONS, AND FASTENING OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO ASSIST THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL. 1. DETAILS SHOWN IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR SHOWN. DETAILS OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE OF THE SAME NATURE AS THOSE DRAWN FOR SIMILAR CONDITIONS. 8. CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT, AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO REPLACE IN KIND ANY SUCH ITEMS DAMAGED, IN ITS ENTIRETY TO LEVEL OF SATISFACTION OF ARCHITECT. 9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER, INCLUDING: SITE ACCESS, MATERIALS STORAGE AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES, AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO VERIFY SEQUENCE OF WORK WITH OWNER 10. ALL INTERIOR GUB 15 I" TYPE X ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZED AS DIMENSIONED ON PLANS. SEE NOTE *11 FOR WATER RESISTANT GWB. IL PROVIDE WATER RESISTANT (PAPERLESS) TYPE X GWB IN ALL TOILET ROOMS, WAREWASH, AND WET AREAS. 12. PROVIDE FINISH WALL BEHIND ALL EQUIPMENT AND CASEWORK. 13. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION. 14. PROVIDE ONE TYPE 5E- 2A -105C FIRE EXTINGUISHER PER 3000 SF AND NOT MORE THAN 15 FT OF TRAVEL DISTANCE, 15. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT NONRATED PARTITIONS_ SEPARATE OUTLETS BY 24" MIN. AT FIRE RATED PARTITIONS. I. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. 11. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. I8. FURNISH AND INSTALL FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTORS SHALL OBTAIN ALL NECESSARY PERMITS. 19. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 20. FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS. 21. ELECTRICAL DESIGN BUILD CONTRACTOR SHALL SUBMIT LIGHTING BUDGET SUMMARY TO CITY OF TUKWILA AS REQUIRED BY LOCAL JURISDICTION HAVING AUTHORITY. Scope of Work SCOPE OF WORK SHALL INCLUDE THE TENANT UPGRADE OF GENERAL, EMERGENCY AND EXIT LIGHTING IN THE WAREHOUSE AREA OF AN EXISTING TENANT SPACE. WORK SHALL INCLUDE BUT NOT BE LIMITED TO: - INSTALLATION OF NEW GENERAL/EMERGENCY LIGHT FIXTURES - INSTALLATION OF NEW EXIT LIGHTING ALONG ALL EGRESS PATHWAYS AND AT ALL EXIT DOORS. - INSTALLATION OF EXTERIOR EMERGENCY LIGHTING AT ALL EXITS Drawing Index ARCHITECTURAL CS1.0 TITLE - COVER SHEET E3.01 EMERGENCY LIGHTING AND EGRESS PLAN Separate Permits THE FOLLOWING ITEMS ARE NOT INCLUDED N THIS PERMIT: - INTERIOR TENANT IMPROVEMENT - FIRE ALARM - FIRE SPRINKLER - MECHANICAL - ELECTRICAL Project Directory OWNER: GRAINGER 100 GRANGER PARKWAY LAKE FOREST, IL 60045 ELECTRICAL CONTRACTOR: SEA -TAC ELECTRIC, INC. COREY MCKINNON 1056 SOUTH 220TH STREET KENT, WA 98032 T - 253.812.5553 F - 253512.4112 D - 253 - 8612354 C - 206 - 406 -2801 COREYI195EATACELECTRIC.COM ARCHITECT: RBA DESIGN, PLL.C. 94 UNION ST SEATTLE, WASHINGTON 98101 CONTACT: BARBARA GRUBB T - 206.623.9125 X 106 BARBARAGGRBADESIGN.COM REVIEWED FOR CODE �R C APPROVED CE A p JAN 042013 City of Tukwila BUILDING DIVISION NORTH GRAINGER Site Plan TODD BOULEVARD 0 z w w cn -w - ASPHALT PAVEMENT 4]' -s 1/e GRAINGER AREA OF WORK unanelce schedule 64 FIX en9ee SeGLe • .::p Lu9ens nescxlpcl 2798 0.700 le 95 50.-0• 50' -0• 48' -1 1/2^ 51' -11 1/41 41' -2 3/41 .. 1'-41 ■ Itr7t e: �Jb* JE' dh�l r�+!! �!l rIFiPIFaIMil Wal �d^ r. iCr: m' ^.Q.."i'Qi'�iGVE-07.F.: r3ms .F � s � s'Th .i / w /wwww /w w/Iww CCL.s"71 irLf nL:rrfi�,�iLt''.'�f'"' .fl.tJ fi.�i7 ►- .� /r'L' /.�L'F�.. w j ' OF .. aL.'4e..l i+a iLL. +wl cr447. is.1,f f:' 2. fl.t:.211 ► - _ 0.&.∎ • .IL:'a SLIM NUMMI q �+ ��,{{ �:ii 1 !Ls,.'.7.!4 ' �T.L- gi:-,! IL.,_ W. Al., FA ft _'� .I a? -fit -nl F•7,�• ._�'' 7 :1 F -'t3�' ,��, j 1.Y / w/Iww /w /I/ww /wwIMA %I r PI dle �r r.� �'���rl� .:ate ��1 511. 1s.:a�ws. . - rs:L:MI • wsr.L'Ww �I dI: 212 u� d•jP I.] I �■7 �EJ, . �. .. 5Pv7. ".t7. :7.IGi.'i l�...iMI ice.... 4 LPP4......L�'G'7J� . '� "' '" OC'_iu. �aF.LCV. L�a�.Lay. , _..tom_ .' .N..= T.:- �:- r`.��► � c� �a . ,,� 1► se..sa III IiIII Jam` .�..IWAI �► u.uuiu;+z 411:rrau1Ltti . • �� „� r r d I frL / �f:' ,,iGIJ iL"F:. w.. .ar a ir:zJ Qom/ caluli 4.I J' NUJ ate% iLMIll a t- Q11 Q _ 1P' +' 11=M ►' a ... L . _P _ .. U . pr AVAIVAM11211/4111,411211112WAPFAIPIAPFAIIIIIIIMIAMMIANEW .1 Lz ,m -- J L� u:� �.. ,L...� a ..�._ .Ir.. i . z...=_ .. . d •2111111+2.1111 t 4:4"72‘1111:C111 ..4LI/fL.J I.1:C7 aQ.L,7 P- Nair IL.V /YL.J r4,7I L f.Lt.a,a4�7 111:-.3111 II WAN .....7I ULAN 7.� :. %ww��w.� aar: =r_ c ar. AlIVAIVAIVAIWAVAIS w�wMrw maxi 111ZJIN ilLV-1111r.w•. MAIN E°.sa. wwwwwt. Z_7 a wI wwwwww- Iwww /Iww/ fr Es ID . r. JII i a 7-1 1 1 II., s t: • `'��'` � 1. n G.,211 n „.s._ : - 1 1 1 6 SPACE . WALK 1 101 SPACES 1111 gym •cam ..... -. ° - -_ ASPHALT PAVEMENT DUMPS TER 1 1 1 7 SPACE 396.0 , 7 ISPACES S ASPHALT PAVEMENT 4 SP?s.CES _w . U -w' 94 Union Street Seattle, WA 9810I 206/623.9125 SEA,4t1TAC ELECTRIC INC. 7056 SOUTH 220TH STREET KENT, WA 98032 PHONE (253) 872 -5553 FAX (253) 872 -4112 • W z(/) DEC 262012 REGISTERED ARCHITECT RODNEY A. BAUCH STATE OF WASHINGTON 111 N Revision Date Description 12/IS/2012 PERMIT SET LTR# CORRECT /ON LTR# Scale Job Number Drawn VARIES 00- 000.00 csM Date 12/18/2012 Checked RBA TITLE -COVER ) SHEET CS1.0 I =1 Luminaire Schedule Symbol Qty 64 Label Arrangement Total Lamp Lumens LLF Description FIX SINGLE 2748 0.700 IB 454 0 W Q r —I TRAVEL DISTANCE 141 LF 22' -1 1/4" 2009 IBC MEANS OF EGRESS ILLUMINATION 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. 1006.2 Illumination level. The means of egress illumination level shall not be Tess than 1 foot - candle at the walking surface. 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways... 3. Exterior egress components... 4. Interior exit discharge elements... 5. Exterior landings...for exit discharge doorways... 2009 IBC MEANS OF EGRESS ILLUMINATION lighting 1006.4 Performance of system. Emergency g g facilities shall be arranged to provide initial illumination that is at least an average of 1 foot - candle and a minimum at any point of 0.1 foot - candle measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot - candle at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ration of 40 to 1 shall not be exceeded. 47' -5 1/4" 50'- " 50'- " REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 4 2013 City of Tukwila BUILDING DIVISION TRAVEL DISTANCE 146 LF TRAVEL DISTANCE 211 LF 48' -7 1 2" 51' -11 1/4" 47'-2 3/4" 16U41 52•M 18U41 WW 16U41 5Y UP 16041 52'UP 16U41 52• UP 16041 WW 18U41 52'UP 16U41 52• UP 18U41 52° UP 16U41 52 UP a' • k. 1 TRAVEL DISTANCE 178 LF PAVEMENT ASPHALT 52" UP 16U20 1 ■! 16U41 16U41 16U41 16U41 16U41, 16 1 16U41 16U41 gam ism 09 10 11 12 13 NOM 16U20 ' 16U20 ' 16020 I 16U20 1116U20 ' 16U20 16U20 I 16U20 16020 SAME I6Td I 16U20 ' I16U20 16U20 1 SAME I SAME SE -I 1 SAME ' 16U20 I SAME I SAME I ' SAME • 16U20 16U20 116U20 116U20 111 16020 I 16U20 I 16U20 I 16U20 1116U20 I 16020 f> I 16U20 I 116020 I 16020 I 16U20 I I 161120 h_..16U20 1 16022 I 161)20 16U20 I 16U20_I 161)20 ite,T1 16020 . 6U2L_ I 16U20 I6UZQ_ I _1fU20 ^I it SAME I SAME 11 SAME I 16U20 16U20 16U20 1 16U20 E 1 SAME SAME I SAME II 16U20 16U20 1 18U20 16U20 I 16U20 1 16U20 I 16U20 I 16U20 I 16U20 I 16U20 SAME SAME SAME 16U20 SAME SAME 16U20 1!) 16U20 I 16U20 1 SAME I SAME II16MBZ10 E - SAME- 16U20 1 SAME { SAME { SAME 16U20 16U20 16U20 SAME-4 SAME I u SAME —I 16MBZ10 16MBZ10 .16MBZ10 I 16MSZ10 - '-10- 16MBZ10 - 1- 36MBZ10 1 tl7 16U20 I SAME I SAME I SAME I SAME 16MBZ10 116MBZ10 16U20 16U20 16U20 16U20 16U20 16MBZ10 116MBZ10 to 16MBZ10 I 16MBZ10 21'- • 0 z �O VI Ar 161120 16U20 16U20 16U20 16U20 16U20 -'16t120 161720- IT't6U20 16v1u mlw =MI 16U20 16U20 16U20 16U20 16U20 16U20 5TPRT 16U20 16U20 16U20 16U20 - '161J20 161120" WORT 1016U20 j 16t120 REPLACE END FRAMES & COLUMN TYP. FOR ALL 01 HLIGHTED (SEE ELEVATION CONFIGURATIONS �` ETAILS) r U) N M U) r- N N r-4 M M fn u, N N w co M • c1) N N r-1 U) r• U) N N r-4 16MBZ10 16MBZ10 t() 16MBZ10 16MBZ10 calt� 16MBZ10 f 1UMBZ1 Y 116MI3L10 j6MBZ1U REPLACE END FRAMES & COLUMN ••.r'.CTORS fill TYP. FOR ALL HIGHLIG : FRAMES (SEE ELEVATION CONFIGURATIONS DETAILS)r I 16U20 1 16020 16U20 I 16U20 SAME I SAME SAME 1 SAME { SAME SAME SAME- -SAME SAME- ME SAME 1 SAME 1 SAME 10 SAME SAME SAME SAME SAME fir) • SAME I 1 16020 I 16U20 11 16U20 I 16U20 PHASE -II 1 1 SAME SAME 1 SAME SAME I SAME SAME SAME I I SAME SAME SAME SAME SAME SAME SAME V' s \- PHASE -II 1 MANIFEST SYSTE 63. SAME 1 SAME { SAME SAME SAME SAME 1 SAME SAME -A x® M U) 01 N r� ri FIX ri r4 V' d' N(0 W W TA rI e. N H H N W u)ID N N m c N N r4 1-4 Cr Cr "VD W si r-4 H 1 -1 (1) U)r- m N 9 6''' -' w' (0 r-4 ri ri '-4 m 0 N ri N r1 M CO u) N '•-1 r4 M u M N '-1 r-1 r-4 (Y) N ri t0 O • M U: C r• (Y) WILL ALL 6'UP 16'UP C14 x 33" P 16HC14 6HC14 t x 33" 30? CE JP JP 6HC14 x 33" P 6HC14 6 ' 4 6HC14 2x33" JP 33" x 33" 6HC14 3'',. y33cE P P P UP 0 SPAC TRAVEL DISTANCE: 132 LF TRAVEL DISTANCE: 132 IF TRAVEL DISTANCE 122 LF ASPHALT P ` I EMENT • ' P ER 6 SPACE SdS TRAVEL. DISTANCE: 110 LF 7 SPACES EC3RE$S PLAN #1 SPRINKLER NOTE: HEM OUTBOUND DOCKS # 2 r� # 3 c� #4 0 0 N c) U)n • N O ri M U) 0 r-4 U.' VI U) M NO ri M • (Y) r♦ U) O NN r-1 N N N ra V' r4 � ri V- ' l0 ri 01 O .-I N r ID r•1 .-r ri V' l0 ri H r-4 W ra r-♦ r W ri 14MUti.1 Yft4BMCM uHEEN1EBEHEENUEEMEME 14 Aso' - r eN ul v7 NW W" 73-75' Ln N V N 0 N lD W N r-4 e-I N N (. N 15 16 N W W"1" r-1 r- 4 V' V' o n " N W W i H 1-1 O (. 9671 -1 moo, ri O L4) l0 ri O W H M ri 0 r-4 V• O la W ri N O o O ri ri N 'C1• wl0 WW ri ri C O O '4 r o QD r-I O () ra r-4 V. W ra N 5 2 r4 r1 M C ri r4 0 W ri O to l0 •--1 o'er 41) 0 W l0 O O °1 ko ri r-I W ri N CV N 4,) N r� N tl4 la ' -4 a� N.~% ri N N N m N CO W ' -I ri N N CO CO W W H ri r, • '_'4 N N co OD W lD ri r-1 ri ri ri 01 0 ° ri ri ri G' Cr CO W W o V' V' W 3 :D N O cn W O r-4 r4 ri Tr o '7 W ri ri V' rl t0 ° ri rI H CD rl N V' W .0 g E W .0 ra r♦ INBOUND DOCKS #5 #6 #7 0 tD O V' 0 N N ID 0 '-4 O M 0 eal� 1]+t Y® 1. THE SOUTHERN SYSTEM IN THE MAIN BUILDING IS ARRANGED AS A CENTER -END TREE, USING LARGE -ORIFICE, 286 °F RATED HEADS. SPACING BETWEEN READS ON A BRANCH LINE IS 9 FT. 3 IN. SPACING BETWEEN BRANCH LINES IS 10 FT. THERE ARE TEN HEADS PER BRANCH LINE, FIVE ON EACH SIDE. THE FEED MAIN IS 4 IN. CONNECTING TO A 6 IN. RISER. THE SPRINKLER SYSTEM WAS ANALYZED AND CAN PROVIDE A 0.36 GPM /SQ. FT. DENSITY OVER THE MOST REMOTE 2,500 SQ. FT. AREA, PLUS 500 GPM FOR HOSE STREAMS. 2. THE NORTHERN SYSTEM IN THE MAIN BUILDING IS ARRANGED AS A LOOP, USING LARGE- ORIFICE, 286 °F RATED HEADS. SPACING BETWEEN HEADS ON A BRANCH LINE IS 9 FT. SPACING BETwR.N BRANCH LINES IS 10 FT. THERE ARE NI4E HEADS PER BRANCH LINE, FIVE AND FOUR ON EACH SIDE. THE FEED MAIN IS 4 IN. CONNECTING TO A 6 IN. RISER. THE SPRINKLER SYSTEM WAS ANALYZED AND CAN PROVIDE A 0.4B GPM /SQ. FT. DENSITY OVER THE MOST REMOTE 2,500 SQ. FT. AREA, PLUS 500 GPt4 FOR HOSE STREAMS. SYMBOL KEY: - - DENOTES EMERGENCY LIGHTS LOCATION - DENOTES MAN DOOR EMERGENCY LIGHT LOCATION ® - DENOTES EMERGENCY EXIT SIGN LOCATION SCALE: 1/16" = 1' -0" n' ELECTRICAL'. m 7 CO CO OD CO N CO W r-1 N CO tO ra co TRAVEL DISTANCE: 119 IF TRAVEL DISTANCE: 139 LF 7 SPACES ASPHALT PAVEMENT bo, 4 SPACES 17' RBA des' nplic 94 Union Street Seattle, WA 98101 206/623.9125 SEIVITAC ELECTRIC INC. 7056 SOUTH 220TH STREET PHONE (253) 872-5553 KENT, WA 98032 FAX (253) 872-4112 1.14 E-04 (1) 11 P-4 gLiq (9) 06537 cox sc; o REGISTERED ARCHITECT RODNEY A. BAUCH STATE OF WASHINGTON Revision Date Description 12/1E3/2012 PERMIT SET Da, 2 b 2012 Scale Job Number 00-000,00 Drawn CSM Dote 12/18/2012 Checked R5A EGRESS PLAN E3.01