Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D12-335 - RAINBOW TRAILER HAVEN #7 - RV
RAINBOW TRAILER HAVEN #7 3714 S 152 ST D12-335 City off ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0041000660 Address: 3714 S 152 ST TUKW Suite No: Project Name: RAINBOW TRAILER HAVEN #7 DEVELOPMENT PERMIT Permit Number: D12-335 Issue Date: 07/25/2013 Permit Expires On: 01/21/2014 Owner: Name: VIP 3614 LLC Address: PO BOX 28 , KIRKLAND WA 98083 Contact Person: Name: JARED VARNES Phone: 206 973 -6003 Address: PO BOX 28 , KIRKLAND WA 98083 Contractor: Name: OWNER AFFIDAVIT - JARED VARNES Address: Contractor License No: Lender: Name: Address: Phone: Expiration Date: DESCRIPTION OF WORK: INSTALL RV IN EXISTING MOBILE HOME PARK Value of Construction: $2,000.00 Fees Collected: $212.40 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -335 Printed: 07 -25 -2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non- Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: 7-92- ( 3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building doc: IBC -7/10 D12 -335 Printed: 07 -25 -2013 Department (206- 431 - 3670). Il 8: VALIDITY OF PERMIT: The issuance or gran ling of a permit shall not be construed to be a• it for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -335 Printed: 07 -25 -2013 CITY OF TUKTA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Pro ect=No J. ,',Date`Appliication Accepted Date Application Expires (For ojJce CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.:,Ot./ '1 I — ODO 66o Site Address: r31.1 t . ) 5 17d S4- 4 Suite Number: Floor: Tenant Name: New Tenant: ❑ Yes ❑..No PROPERTY,OWNER : . < Name: 1`c U UA"�1 Name:...V1p..36"1, ._,„ 1/VQ Address:: ?Q teat' ��/ 11I�ll Address: ail( 2g City: 1 �l l/�� 0 State: �� City: tj K ,A /0 State: >, , / Zip: q of Q_ CONTACT PERSON 7 person receiving all project ,communicattion�/ < Name: 1`c U UA"�1 Address: Address:: ?Q teat' ��/ 11I�ll Architect Name: City: 1 �l l/�� 0 State: �� Zip:q f�o Phone: -7,0b c - _,600 00 ax: Cit y: State: Email: Zia (rl?P,s is 6i 1Yi(1 1 , C o Al v v GENERAL:;CONTRACTOR INFORMATIONw , • ; ,,;. Company Name: Address: Architect Name: A/7/i Zip: Cit y: State: Phone: Fax: City: ,/1-7///- State: Contr Reg No.: Exp Date: Fax: Tukwila Business License No.: Email: H:Wpplications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh ;ARCHITECT OF RECORD,; Name: Company Name: Architect Name: Address: Address: City: City: ,/1-7///- State: Zip: Phone: Fax: Email: ENGINEER -OF.RECORD ' x Name: Company Name: Engineer Name: Address: Address: 74 City: City: State: Zip: Phone: Fax: Email: L1ENDER/BOND ISSUED (required forVojects $5;000 or 1 :greater per ,RCW ,19 27:0 5 .. ... _ Name: / - , -, Address: City: State: Zip: Page 1 of 4 BUILDING TERMIT ,INFORMATIO6206 - 4313670;,.. Valuation of Project (contractor's bid price): $ 2( WO Describe the sco e o work (please provide detailed information): 1151—a 1 ' V 0 e-' i 4-711 y /14041 Ho p . Pa I7 Existing Building Valuation: $ Will there be new rack storage? ❑ ....Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Squar'eFootage Below Existing Interior Remodel "i ': Addition to. Existing `. Structure . _Type of Construction per, 'IBC Type of Occupancy per IBC' Floot nd Floor 3rd Floor Floors thru Accessory Structure *.! Attached Garage' Detached Garage 'Attached Carport Detached Carport :Covered Deck ,Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over_ 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm Compact: Handicap: If "yes ", explain: None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 PUBLIC WORKS PERMIT INFLATION — 206 - 433 -0179 Scope of Work (please provide detailed information): 7jQM pet? - (- (e tLt. C � ,/ cc / 7- (4,4,(( t/1 e � .CtIef- u h 99A /2 /7e c ed ..-- Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑... Highline ❑ ...Valley View ❑... Renton ❑ ...Sewer Availability Provided ❑... Renton ❑... Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance 0... Easement(s) ❑.. ❑.. Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - No Disturbance ❑ .. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation ❑. ❑. ❑. ❑. Geotechnical Report . Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0... Right-of-way Use - Profit for less than 72 hours 0... Right-of-way Use — Potential Disturbance 0... Work in Flood Zone 0... Storm Drainage .. Abandon Septic Tank .. Curb Cut .. Pavement Cut .. Looped Fire Line Domestic Water ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public ❑ ❑ .. Water Main Extension Public ❑ ❑...Grease Interceptor ❑... Channel ization ❑...Trench Excavation 0... utility Undergrounding WO # (2) " WO # (3) WO # (2) " WO # (3) WO # ❑ .. Deduct Water Meter Size Private ❑ Private ❑ " WO# " WO# FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: city Water Meter Refund/Billing: Name: Mailing Address: State Zip Day Telephone: City State Zip H:\Applications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTE fa Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN - OR : ! NT: Signature: Print Name: J Mailing Address: 60 i( H:\Applications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Day Telephone: Date: 107/6/( 6/( City GsvA Zip Page 4 of 4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0041000660 Permit Number: D12-335 Address: 3714 S 152 ST TUKW Status: PENDING Suite No: Applied Date: 10/16/2012 Applicant: RAINBOW TRAILER HAVEN #7 Issue Date: Receipt No.: R12 -02877 Payment Amount: $212.40 Initials: JEM Payment Date: 10/16/2012 01:51 PM User ID: 1165 Balance: $0.00 Payee: JARED VARNES TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 75927D ACCOUNT ITEM LIST: Description 212.40 Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $212.40 126.00 81.90 4.50 doc: Receiot -06 Printed: 10 -16 -2012 INSPECTION •RECORD Retain a copy with permit.Z X335 INSPECT!, N NO PERMIT NO.6 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 43.1 -3670 Permit Inspection Request Line (206) 431 -2451 Pr ect: A,':I CI L") `fie , (J r Type of Inspection: e Ai AA 3,), Lo, A Address: Yi 1 '� . i S ?- -5`(- - Special Instructions: 4-1 Date Wanted: a.m. Requester: Phone No: Approved per applicable codes. t� Corrections required prior to approval. COMMENTS: F'rM 1 1-c? �( Ins t ctor: Dat O i_3 REINSPECTION FEE EQUIRED. P for to next inspection. fee must be paid at 6300 Southcenter Blvd.. ui e 100. Call to schedule reinspection. w�PtitPfi�'':'. _ r. c.. - X .. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. 6, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Projec: r rca ,1 n 5 Otd "froi ef (41----- Type,o1.1nspection:__ „ ---,‘ A. I AA au. ,‘ t . A6 Address: ri (4 i52 Sr- Date Called: -3 Sal Instructions: Date Wanted: i 0 ,--7,-- G a.n. • . Requester: Phone No: 7,A0(0AP/ Approved per applicable codes. orrections required prior to approval. /) COMMENTS: Aes A ,r7* Date: Inspctor: 110 REINSPECTION FEE R Q1i1.11 E :Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., uite 100. Call to schedule reinspection. 31-11-A t5 ds U\<\,/117A- U-1 0 SEPARATE PERMIT REQUIRED FOR: ®'Mechanical EElectrica! erPiumbing (,areas Piping City of Tukwila BUff_.rNNG DIVISION PLANNING APPROVED . No changes can be made. to these plans without approval from the Planning Division of DCD Approved By:, -1?) Date:. IA 00 t- 1rt -000 p 1 19.3(6 - \\ FILE COPY Permit No. P1P.n review approval is subject to errors and omissions. Jrr el of construction documents does not authorize the : ation of any adopted code or orj� e. /Receipt of epproved Fold 1 :I I y I is admowledged: By Date City Of lbkwila BUILDING DIVISION REVISIONS No changes shall be made to the scope i of work without prior approval of ukwila Building Division. 1 h;^ i F,evisions will require a new plan submittal ( and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 2 2013 VAL City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 16 2012 PERMIT CENTER D12 -?,3S Vinyl Skirting Panels for Mobile Home Manufactured Housing FXLE COPY call us t: it„ 1- 800 - 367 -2275 7/10/13 1:36 PM Doors & Windows Interact with us. See how we make mobile home residents happy Y P'unit:Mg rttirig,S .. - GeoTrust• prick to ..'1 10-Jul-13 20:36 GMT Home > Skirting > Vinyl Skirting Panels r4) Description 11'8" x 16" skirting panel Our Price: 511 99 Sale Price. 59.99 Product Code SKIRTING101 Color *: White Qty 1 Mobile Home Vinyl Skirting Panel AOD TO'CA T !,► REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 2 2013 City of Tukwila BUILDING DIVISION PY.tL"' iai�i' Single vinyl skirting panel measuring 11'8" long by 16" wide. Read more about how to buy vinyl skirting to completely "trim out" your mobile home. Purchase individual panels from this page, or if you are looking for a complete vinyl skirting package, check out our all -in packages for the dimensions of your home. Manufactured Home Vinyl Skirting Panel • Vinyl panel resistant to damage • Long - lasting all- weather skirting • 11'8 "1 x 16 "W (often referred to as a 12' skirting panel) • Ind vies, of l:inel Mobile Home Vinyl Skirting Panel Shipping and Delivery CompleteMH delivers the vinyl skirting panel from our warehouse directly to your door. For shipping rates to your location, add the mobile home vinyl skirting panel to your Cart, enter your zip code, and click Recalculate. Choose Ground or Expedited delivery depending on your needs, and we'll get your order shipped right away! Manufactured Home Vinyl Skirting Panel Price Match Guarantee Complete Mobile Home Supply proudly offers the lowest prices on thousands of parts in stock including this vinyl skirting ponel. Customers repeatedly choose CompleteMH because of our industry-leading expertise and customer service, in addition to our low prices and great value. If you find another retailer with a lower price on this manufactured home vinyl skirting ponel, contact us and we'll be glad to match it! Conditions on price match: • Must be online store price of an authorized dealer of product. • Not a loss- leader or clearance price. • Must be identical mobile home vinyl skirting panel sold in brand new condition. Customers Also Bought... Vi;r:l S-:'ting n.,ck„gc 16x70 Mobile Home Our Price: 5624.00 RECEIVED CITY OF TUKWILA CORREC ION JUL 1 0 2013 LTR# PERMIT CENTER Vinyl sku ung Package 14x70 Mobile Home Our Price: 5624.00 littp:// www. completemobilehomesupply .com /ProductDetails .asp ?ProductCode= skirting101 K -Rok EnLre House Skating Package - 48" Total Our Price: 52,299.00 Vinyl Skirting Package 28x70 Mobile Home Our Price: 5720.00 A lx-- 33,5" Page 1 of 2 Minute Man 028 892 0298 09 /Z2,'05 08: S am P. 005 FILE 'COPY INSTALLATION INSTRUCTIONS FIRST CHECK FOR UNDERGROUND UTILITY LOCATION: EZDH EARTH AUGERS 1 DETAIL THIS BOOKLET FOR INSTALLATION INSTRUCTIONS. E,ARTH AUGERS 1. INSTALL AUGERS INTO SOIL WITH CONSTANT DOWNWARD PRESSURE TO MINIMIZE SOIL DISTURBANCE LEAVING APPROX. 12" OF SHAFT EXPOSED. 2. INSTALL STABILIZER PLATE - DRIVE FLUSH WITH GROUND SURFACE. 3. COMPLETE TURNING AUGER INTO GROUND UNTIL AUGER HEAD IS FLUSH WITH GROUND SURFACE AND TOP OF STABILIZER PLATE. CROSS DRIVE ANCHORS 1. CROSS DRIVES ARE USED WHERE HARD ROCKY SOIL OCCURS. IF THE GROUND SURFACE IS OTHER THAN ROCK OR MINIMUM 2' ASPHALT, INSTALL MMA -S02 STABILZER PLATE, OR PLACE 121c121(17' DEEP CONCRETE. CONCRETE SLAB ANCHORS. 1, CONCRETE SLAB TO BE MINIMUM 312' THICK AND IN GOOD CONDITION. 2. MINIMUM SLAB AREA REQUIRED FOR EACH ANCHOR IS 28 SQ. FEET. 3. DRILL PROPER SIZE HOLE IN SLAB MINIMUM 12" FROM ANY EDGE. ALL APPLICATIONS 1. ATTACH STRAPS TO CHASSIS BEAM IN MANNER SHOWN. 2. INSERT STRAP THROUGH SPLIT NUT. CUT OFF EXCESS STRAP AND TIGHTEN UNTIL SNUG. END TIC DDWN$ SEE CHART ' v SINGLE WIDE EARTH AUGERS CROSS DRIVE ANCHORS TIE DOWN LOCATIONS w ENO TIE DOWNS SEE CH.R7 1 r 1 1 1 1 DOUBLE WIDE MFO'O I-4OME 135'1541177i MAX. MAX LENGTH OF ND sloe 1 213 141 MAX. LENGTH OF MFD'D . pME • MAX. NO, OF SIDE T?E DOWNS SEA 1 �0 1 �r r �r r ;r r v v v TRIPLE WIDE 42' 52' 62' 73' ,„ REVIEWED FOR YCODE COMPLIANCE f'" APPROVED 1 JUL 2 2 2013 City of Tukwila BUILDING DIVISION CONCRETE SLAB ANCHORS MAX, LEON OF Wen) HOME 34' 42' Sa' 59' 68' NOTE: IF OBSTRUCTIONS PRECLUDE THE PLACEMENT OF THE SIDE TIE DOWNS AT THE 2' LOCATION SHC SIDE TIE DOWNS AT 2' -0" FROM EACH END HAVE A TOLERANCE OF 1'tRECEIVED CITY OF TUKWILA --f I--18" MIN. :0 TO 5 BOLT ON TOP PIER "'cNO *'"-- ' END TIE DOWN VOTE; TIE DOWN STRAPS`- ATTHE CHASSIS BEAM ENOS-TEND TIE DOWNS) CAN BE ATTACHED TO A CHASSIS L1J SuPPC,RT ?iERR WITH A P!EP COLT ON TOP. (SEE SKETCH ABOVEy C? _ D d CORREQTION LTR# JUL 1 0 2013 PERMIT CENTER Minute Man 828 692 0258 '.:;.'(;VIN. SEE rC--,u{: -"R J _ �'•�- SHOE ''E DOWN 3 ?VT 80LT *NO NU1 1 NC4636 EZDH &•MMA34 EARTH AUGER TIE DOWN ORILL 9/1G" HOLE AT IAD HEIGHT OF BEAU, INSTALL 1/2" A307 BOLT. STEEL 5'TRAP FOR TIE DOWN CANCHOR "=O. STRAP SEE-I -EXAM CHASSIS "C" BEAM CHASSIS 1R TIE OWN A OR 'RFC" BEAM CHASSIS 1/7H 09/22/05 08:58am BEAM SHOWN, SEE C.& Rrc-cHAssis rort ENO TIE DOWN CONNECTIONS uuA34 rRAME TIE STABILIZER PLATE - SIDE TIE COwN ORIU. 9/16' HOLE AT WO HEIGHT OF BEAM. INSTALL I/2" A301 OCT. B EARTH AUGER TIE DOWN INSTALLATION INSTRUCTIONS 1. THE DRIVE MACHINE IS STARTED AND THE ANCHOR 1S TURNED INTO THE GROUND TO A POINT WHERE THE TOP (STABILIZER HEAD PLATE) IS FLUSH OR SLIGHTLY BELOW GROUND LEVEL THIS INSURES THAT THE E Z ANCHOR STABILIZER WILL BE AT ITS REQUIRED INSTALLATION POSITION. 2. FOR THE E -Z ANCHOR /STABILIZER TO ACHIEVE FULL POTENTIAL., INSTALL THE ANCHOR VERTICALLY WITH NO DEVIATION GREATER THAN 10 DEGREES. NOTE A SLIGHTLY GREATER ANGLE MAY BE USED TO START THE ANCHOR TO AVOID CONTACT WITH THE HOME & STRAIGHTENED AS THE ANCHOR IS GROUND SET. THE SPLIT BOLT IS INSERTED, STRAP FASTENED, AND TIGHTENING ADJUSTMENT MADE. NOTE: WITH MACHINE INSTALLATION, A MINUTE -MAN ADAPTER DESIGNED TO FIT BOTH THE ANCHOR HEAD AND DRIVE MACHINE SHAFT IS AVAILABLE. INSTALLERS DO NOT NEED ADDITIONAL OR SPECIAL EQUIPMENT FOR E -Z ANCHOR INSTALLATION. NOTE: AN ADDITIONAL STABILIZER PLATE IS NOT REQUIRED WITH EZDH & GW2 EARTH AUGER TIE DOWN. CONCRETE TIE DOWN CROSS DRIVE TIE DOWN CHASSIS u41A4 FRAUE 3 TIE /700: 7' 17CEL :,TRAP wAM MCC( I -BEAU SHOWN, 5EE C "& RFC "CHASSIS TOR ENO TIE DOWN CONNECTIONS MM 34 rRAmE NTGUSTRAP W/ STEEL Ttt SIOE TIE GOWN SPLIT BOLT & NUT STABUZER PLATE GROUND LINE ,.r — CRCSZ ORNE ANCHOR M SP_QSS DPivE w/ S A9 LIZc,� — DI AT ,r1: Tni, .. FRAME TIE TO ANCHOR Manufactured Home •,me Tie With Buckle I Beam e Frame Ground Level If this angle exceeds 45`, frame clamp with strap must be added to the opposite beam as indicated by the dotted lines. Proper earth anchor with stabilizer for soil condition (or approved alternate i.e. E -Z Anchor) FRAME TIE INSTALLATION INSTRUCTIONS 1. in,ead :ue,pent length of frame be strap through buckle as shown. am and Peer of hone. Bnng strap to thread n seep between round fame and back through buckle es shown diagram and fasten to anchor hea Diagram showing 51ra0 n posrt0on around d u Move as slack hem system. to pproorw salternate s, single drekb ,s a + Enlarged View of Frame Beam Place buckle at tope/ anchor vde of beam, pass wraparound beam and through buckle. Pass strap back around beam and througn buckle to anchor Strapw,ll wrap beam Nome. Remove all slack from system. Enlarged View of Frame Beam Attach Frame Clamp (Hook) inside top flange 01 home frame. Bring strap around frame. ame and home as shhown ,n f sketch. P011 strap fight and attach to anchor lensien head. "SUGGESTED RECOMMENDATIONS WHEN USING CRIMP ING SEALS" The strap must be identified 'MINUTE MAN ANCHORS INC. CERTIFIED ANSI 225.1 AND ASTM D3953." WHEN EXTENDING OR SPLICING TWO STRAPS. OVER LAP APPROX. 6". USE TWO SEALS FULLY CRIMPING EACH SEAL TWICE TO BOTH STRAPS. 3. WHEN STRAPPING TO AN APPLIANCE SUCH AS SLOT IN A VERTICLE TIE OR A HOOK OR A BUCKLE WE SUGGEST THAT YOU USE A SHORT PIECE OF STRAP (RADIUS CLIP) BENT 180 degrees IN DIRECT CONTACT WITH THE APPLIANCE. IThis will act as O Cushion, reinforce and prevent Sharp bends in the Shop,) NEXT INSERT THE STRAP BENDING IT OVER 180 degrees BACK TO THE STRAP USING ONE SEAL. PLACE BOTH STRAPS INTO SEAL AND CRIMPTWICE. SEALS MUST ALWAYS BE CRIMPED TWICE. 5. PLEASE NOTE: TWO SEALS REQUIRED WHEN SPLICING TWO STRAPS. ONE SEAL WHEN BENDING 180 degrees, eaaea 0$ - 3• to e• ' e r file STRAP enNg3a 2ID • catrim. 1,94, 005 TING te:STS Nat sear mo ASTM 53953 Gsn SNAP-Oh SEAL r -v . PIM . 2-3/16 ACm ANA 13 E -Z ANCHOR INSTALLATION METHOD t Nth mamono mslallahon. a Men/to-Man adapter designed to /t both the anchor naafi ono onve rn ;haft is avwlahle, lnstaonrs do not need andihonal or .special o Lnernent for E -Z Anchor /nstnrlalron. E•Z Anchors are a patented item. arhine 1. MACHINE INSTALLATION The drive machine is started and the anchor is turned into the ground to a point where the top (stabilizer head plate) is flush with Or slightly below ground level. This assures that the E -Z Anchor Stabilizer will be at its required installation position. See Figure A. To achieve full potential, install the E -Z Anchor vertically. A 10''deviation from vertical is acceptable. See Figure A. Note: A slightly greeter angle may be used 0 start anchor to avoid contaC1 with the home and straightened as anchor is ground set. The splltbolt is nserted. strap is fastened. and lightening adjustment made. E -Z Anchor carries U.S. Patents and manufacture is exclusive to M /nuts -Man Anchors, Inc. 2. STANDARDS FOR INSTALLATION • E -Z Anchors and all components are to be installed per manufacturer's instructions. • E-Z Anchors are approved for designated Soil Class III, IV. • E -Z Anchor working load capacity is 3,150 pounds for a single tie or the load of (2) ties combined.. See Figure 8. • Consult manufactured home set up instructions for number of frame tie downs, over the roof tie downs and tie down spacing. • Proper site preparation requires removal of grass and sod prior to installation. Stabilizer Head For additional information copies of engineering test(s) and report. Contact Minute -Man Anchors, Inc. CONCRETE ANCHOR INSTALLATION 210 PDH CONCRETE ANCHOR ON INSTRUCTIONS THDHLS CONCRETE ANCHOR 00/51E 4100 SLAB ANCHOR MINIMUM HC8ZON1Al 110110 SCALE E AOCHOn NOTE: Your set must be designed by a Registered Professional Engineer if The location is within 1500 feet of the coastline. The allowable working load on concrete anchor models 210 PDH. THDHLS, and 210 JOH is 3,150 pounds vertical for single Or double ties in 3.000 PSI concrete. There must be a minimum 4" Of distance from The edge of the concrete to the center of the anchor shaft ,Anu, ,,.;,t 210 JOH CONCRETE ANCHOR •u . clan .St Cent... CLIP t0 SiAwin,.V.CcCo 4001101150, •M•SE nzleAC, Pevkaed ._ 3.14.57 — ,��':WS .,251 !NM 42 'PIA VEnr n e' f,Oft.: 11250. JANUARY 9, 2007 MINUTE MAN ANCHORS. INC. 305 WEST KING STREET EAST RAT ROL1(, NC. 26726 DEAR 96 ROD M. HUDGINS, IR. P.E. PI. I015170 AMU, 0.C•2t013 -son T HAVE ANALYZED DESIGN DRAWING. PHYSICAL TESTING REPORTS ANO INSTALLATION INSTRUCTIONS FOR THE MINUTE MAN PRODUCTS LISTED AS FOLLOWS: 65005 5/B 650 OH 11/ 16 6501A11. 760 053/4 636 DH 5/8 636 OH 'd 4636 0H TA 4638 N0 7/8 4430 EZOH 636 Mid A4 650 E20H a/. 660 E20H 6650EZV0H % W/ VERT. STABUZER 8860 EZVOH / W /5ERT STABUZR 443013H 5/8 44300811/16 4430 DH a/. 4442 OH 5/8 4450 DH 11/16 4450 OH s. 36 2 XOH 36 XOH 4E1 50H 36 DH 24 BA 210 0H 210 PIN 210 4DH 100 DH TH0H TH05LS FC1 W/S FCII W,'S BUG W/S SBN MMASD2 MMASOA2 CT /WS CORNER TIE LEIS LONGITUDINAL & LATERAL BRACING SYSTEM MMA 31 LONGITUDINAL FRAME TIE MMA 33 =ONG FRAME CLAMP 11 MMSPP LONG STAB SYSTEM 8.2 ASTS SUPPORT TUBS SYSTEM MY ANALYSLS THESE ANCHORS AND THEIR PHYSICAL CMPONENTS TO BEN EXCESS SOF 1125 POUNDS. THE STRAPPING MEETS FEDERAL SFECIRCATION 012S781 H FOR TYPE I. CLASS B. GRADE 15TRAPPING THE STPAPPNG ALSO MEETS WITH ANSI 225.1 STANDARDS AND ASTM 03953.91 STANDARDS THE STRAPPING 15 1 7. X 035 MINIMUM. HOT DIP GALVANIZED STEEL ON FILE APE TESTING REPORTS OF THE DIRECT WITHDRAWAL STRENGTH OF THESE ANCHORS, THESE TEST EVALUATE THE ANCHORAGE STRENGTH OF MINUTE MEN ANCHORS INSTALLED RESISTING AN AXIAL AND 45 DEGREE ANGLE APPUEO WIHDRAWAL LOAD. FOR THE ANCHORS LISTED ON PAGES 10 AND 11. THE AVERAGE HOLDING POWER MEETS AND/ OR EXCEEDS THE REQUIRED MINIMUM OF 4.725 POUNDS, WHEN INSTAL/101N ACCORDANCE WITH MANUFACTURER INSTRUCTIONS IN THE SOIL TYPES AND [LASS SHOWN. THE LLBS BRAONG SYSTEM WAS TESTED • 01511111 H Cn ROz'-' MINUTE MAN ANCHORS, INC. INSTRUCTION FOR USING MINUTE MAN STABILIZING DEVICE Minute Man stabilizing devices are designed for use with Minute Man anchors and intended to I- lterally restrict movement of the anchor through the soil. Segue Prerensioning snap Stabilizer Plat • Ground Anch • 2' /Or - disk anchor 4- for '10 larger disk anchor the anchors approximately lour inches to the inside exterior wall line 01 the home or a sueic,enl distance , ,md mlenerence with the skimng (see above) trie anchor al an angle of approximately 10 degrees • sert,cal so at the head Of the anchor i5Just outside • ' that id ?wall I see above) ..11 the anchor to a depth of approximately one -Third .., the anchor length. 4. Place a Slabalzer plate to the inside of the anchor shaft (side of shaft toward center of house) and the distance indicated from the shaft. s. Onve the stabilizer plate into the ground until the top of the plate is 1' betow the surface of the ground. 6. Install the anchor to its lull depth. 7. Pretension the anchor by pulling d up to Ile st0bili0ar plate. Pull the anchor approximately ii inch more while ,l is in contact with the plate using the snap and take -up Loh to move the anchor head. Vertical Tension 000000tal Tension Installation Instructions for Cross Drive Rock Anchor • INSTALLATION INSTRUCTIONS Dreg 5/8" diameter hole 5 1/2" deep, 6 center of anchor location, for pilot stud. Insert pilot stud 6to hole. Drill two - 3/4" diameter holes in rock at 45 degree angles, using anchor head as a locating guide. Place rod through top of (1) square tube and into hole. Drive rod to desired depth. (Rod must be driven into rocket least 805. of its length In order to achieve minimum allowable pullout resistance.) Place second rod through top of remaining tube. Drive rod to desired depth to lock. Maximum pullout resistance is developed when anchor head is low as possible and ground surface is solid rock. Distance from square tubing to rock surface should not exceed 1 ". drug °_ •''•_o 'O lnslollOhOn. refer 10 0107 0!x101. 1(019 004'.1 10Oer0) 1pgooriOlfs. to 20cure proper ccvntliofee. ..l!1 10s, 191009 me 07;20 locO915, in 0,oer 10 rr701717 me sot mot/qv/on wan me pr0099r Orx.hCk Alf late "anchors, - Warning: Before grcQd anchor installation. determine that the 07(50 liocatl .s,4 round home will There are two basic methods of installing not be close to any underground electrical cables. anchors, each equally effective in properly water lines or sewer piping. Failure to determine the securing manufactured homes to the ground. location of electrical cables may result in serious CAUTION: The installation of anchors with 0 Personal injury. drive machine is a two person Operation. ANCHOR INSTALLATION MACHINE INSTALLATION In this method, the anchor is turned to full depth it to the ground by an anchor drive machine. Attach anchor to machine. i, Placed anchor in proper position in line with strap and machine. Anchor should be installed at a slight angle as shown to assure head being Positioned behind future skirting, 1. MANUAL INSTALLATION A hole is dug to a depth of approximately % the length of the anchor, in the proper position as explained under machine installation. After the hole is dug to ', the length of the anchor, then the anchor is turned into the ground by hand, using a rod or length of pipe for leverage or by machine. After anchor is installed full depth, earth is repacked. Six inches at a time. PROPER TENSIONING OF STRAP TO ANCHOR HEAD Insert bolt into head: attach nut loosely. Insert strap in slot of • Bend strap 90'and take at least . three complete turns bolt until strap is Bush with I l ms on bolt until far side of bolt. I t e� strap is taut. 2. 3. Bolt is turned with 15/16' socket wrench, Or adjustable wrench, on hex head. With square hole in anchor head, hold bolt under tension while repositioning wrench: Place open -end wrench on 5/8' square shoulders of bolt. Align square shoulders of bolt with square hole in anchor head. Holding hex head of bolt in position, tighten nut to draw square shoulders into square hole. Shoulders are now in locking position: continue 1.0 tighten nut. Tensioning device is now in locked, secure position. Note.: The tensioning bolt can be inserted in the head from either side. 4. Notice: In areas of severe cold weather, where possible damage could occur from frost heave. the homeowner should be prepared to adjust tension on the straps to fake up slack. IN LINE INSTALLED AND CONNECTED GROUND ANCHOR AND FRAME CONNECTION Home I Beam Frame Figure 1 51Mp, ^zer Head Main Beam 1• Anchor and strap./ in straight line ■s' Diagonal frame tie - straping Ground Anchors less than 48" In length should not be installed in line with the pull. Install anchor to full depth (i.e., completely to head) For those homes which are designed to require only diagonal frame ties, the �•. MAO 45° anchor can be installed in line with the ties. Figure 1. Another accepted way to limit lateral Figure 3 deflection is by use of a tested and approved Metal Stabilizing Device. Figure 2 and 3. In Figure 2, the Stabilizer is a part Of the anchor. In Figure 3, the plate is driven in front of the anchor's direction of pull and will act to minimize the anchor rod deflection. See Top of Page 2. LOCKING FRAME CLAMP 1I MMA-33 ASSEMBLED UNIT 0 , 5 1 0 0 . 0 . 5 Bolt & Nut locking Clip Home Frame Pivot Clip must not vary more Minute Man Sera than 10 Deg. from Perpendicular P w Radius cap to Deem. To Anchor July 18, 2013 Jared Varnes PO Box 28 Kirkland, WA 98083 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Request for Application Extension #2 Application Number D12 -335 Rainbow Trailer Haven #7 Dear Mr. Varnes, This letter is in response to your written request for extension to Permit Application Number D12 -335. The Building Official has reviewed your letter and considered your request. It has been determined that the City of Tukwila will extend the permit application expiration date an additional 90 days from the date of expiration, through October 10, 2013. Please note that this extension is being granted due to the fact a response was submitted to the correction letter mailed November 30, 2012. This application is not eligible for additional extensions; it must be approved and issued by the newly granted expiration date. Sincerely, Jennif�Mashall er it ech ician File: Permit No. D12 -335 W:\Permit CenterAExtension Letters\Applications\2012\D12 -335 Application Extension #2.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 -431 -3665 Jennifer Marshall From: Sent: To: Cc: Subject: Mr Johannessen, RE Permit D12 -335 Jared Varnes <varnes @gmail.com> Friday, July 12, 2013 1:51 PM allenjohannessen@tukwilawa.gov Jennifer Marshall Permit D12 -335 CITY OF IiiKWILA JUL 15 2013 PERMIT CENTER I am requesting a further extension of the permit expiration. I recently (admittedly, very late in the allowed time period) turned in what I hope will be the complete information required for the permit. I had assumed that would automatically extend the permit, but was told that I should also send an email requesting and extension. I would like to request a further extension so that my reply can be reviewed and hopefully approved. Warmest Regards, Jared Varnes iiktem,“0-n 610i c2),sA444 cam fre er,14,,1-0 pe/za; -096'2( Allen Johannessen City of Tukwila 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 RE: Permit D12 -335 July 10, 2013 Mr. Johannessen, Please find the attached Revision submittal for Permit #D12 -335. The Manufacturer's tie -down and installation requirements are also attached. The tie - downs were installed per these instructions. Additionally, information on the proposed skirting is attached. We have not yet installed it because we want to make inspection of the tie -downs easier. We will install it if the tie -downs meet your criteria. Regards, ared Varnes VIP 3614, LLC 206 - 973 -6003 CORRECTION RECEIVED CITY OF TUKWILA JUL 1 0 2013 PERMIT CENTER C 06 -03 -2013 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director JARED VARNES PO BOX 28 KIRKLAND WA 98083 RE: Permit Application No. D12 -335 RAINBOW TRAILER HAVEN #7 3714 S 152 ST TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 10/16/2012, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 07/12/2013. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Bill Rambo Permit Technician File: Permit File No. D12 -335 Raav 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206- 431 -3670 • Fax 206 - 431 -3665 April 22, 2013 Jared Varnes PO Box 28 Kirkland, WA 98083 • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Request for Application Extension Application Number D12 -335 Rainbow Trailer Haven #7 Dear Mr. Varnes, This letter is in response to your written request for extension to Permit Application Number D12 -335. The Building Official has reviewed your letter and considered your request. It has been determined that the City of Tukwila will extend the permit application expiration date an additional 90 days from the date of this letter, through July 12, 2013. Please note that this application is not yet approved and has a correction letter outstanding. Before this application can be approved or issued the items requested must be provided and reviewed for code compliancy. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, 1 ;l Jen T ifer Marshall it Technician File: Permit No. DI2 -335 W:IPermit CenterlExtension LetterslApplications120121D12 -335 Application Extension.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 -431 -3665 c 03 -01 -2013 • City of T'u:wila Jim Haggerton Mayor Department of Community Development J ckPace: Drrector JARED VARNES PO BOX 28 KIRKLAND WA 98083 RE: Permit Application No. D12 -335 RAINBOW TRAILER HAVEN #7 3714 S 152 ST TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 10/16/2012, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 04/14/2013. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or your request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall it Technician File: Permit File No. D12 -335 630 OSouthcentei',Boulevard;, Sitite: #100:■ Tukwila, Washington 981$8 • Phone - 206=431;3670 ■ Fax 206 =431 -3665 November 30, 2012 Jared Varnes PO Box 28 Kirkland, WA 98083 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Correction Letter #1 Development Permit D12 -335 Rainbow Trailer Haven #7 - 3714 S 152 St Dear Mr. Varnes, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. File: D12 -335 W :IPermit CenterlCorrection Letters120121D12 -335 Correction Letter #1.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665 • Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Project Name: Rainbow Trailer Haven, #7 Permit #: D12 -335 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide recommended method for tie down details and hardware specifications with manufacturers installation and specifications. 2. Provide skirting details as recommended by the manufacturer. Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -335 DATE: 07 -10 -13 PROJECT NAME: RAINBOW TRAILER HAVEN #7 SITE ADDRESS: 3714 S 152 ST Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued L DEPARTMENTS. 45- C liCF-13 uilding' Division Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 07 -11 -13 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: DUE DATE: 08 -08 -13 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 *EMIT COORD COMO PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D12-335 DATE: 10/16/12 PROJECT NAME: RAINBOW TRAILER HAVEN, #7 SITE ADDRESS: 3714 S 152 ST X Original Plan Submittal Response to Correction Letter #_ Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS. ing lJiviSiG 94u,k/D}cworiAP- Alk\ )0(A, 14.10J41:1■ 9317\ Fire Preve tion Planning Division Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10/18/12 Complete Comments: Incomplete Not Applicable 0 Permiteentei Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 1R3 Structural Review Required El No further Review Required fl REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/15/12 Approved 0 Approved with Conditions 0 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff Initials: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #I00 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: VO/( 3 Plan Check/Permit Number:. (2- ` 3 Response to Incomplete Letter # Response to C rrection Letter # ..L Revision # after Permit is Issued Revision requested by a City Building Innspector or Plans Examiner / Project Name: RAU) I t \!'``L I� v I A-d 11 —371L-1 5 (574(E)- Project Address: 31-1 y S 1 57- S -ree'4 f #1 T /V 1 1 t„,4 Contact Person: Me-c0 t/ V A/PA1 Phone Number: 7-06 - Summary of Revision: ATrAC TH 6 T16 - ov wy iiAAvPA- C17 /Z' LLATtam - QuiIcCr1 -'13 A- NO fiST g X11 NS, T 16 -0QuA s 1A/ETe 1 Ns Tht -L40 Pe M ,w -r -v4Rs 1 JS%1c vGT1 &vS , © n'1 & 14Eo (5 11-16 I,v -R ri art ovu oia TH6 S (•cI MA/6- 1-L- ve o'tzb &1Z o 4I410 F- , -r EFTS YovR KG Q vl Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision iEiVIED CITY OF TUKWILA Received at the City of Tukwila Permit Center by: 'JUL 1 0 2g 3 ) E-- Entered in Permits Plus on 7— ( C t 3 11: \ApplicitionsWorms- Applkati,,n. On I-ina1,2010 Application, \7 -2010 - Rcvi,ion Submiltal.doc Revised: May 2011 PERMIT CENTER • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 FAX (206) 431 -3665 E -mail: tukplan@ ci.tukwila.wa.us Permit Center /Building Division 206 431 -3670 Public Works Department 206 433-0179 Planning Division 206 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: — W2 .c STATE OF WASHINGTON) ) ss. COUNTY OF KING ) " 5 0 U/'-t) U I P N states as follows: [please print name 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration require nt of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number. r °' , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. er/Owner's Agent* VIP -3611 Signed and sworn to before me this O� day of T:--(11. , 20/-5. .&c,e,( c,(C mot= (.4 T Y PUBLIC in and for the to of Washington Residing at /rl /14 Name as commissioned: My commission expires: , County t if —Wer)� 05-0-9 -1 q 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufacturedhome dealer or ai' Pik;. manufacturer; j'4 ,;,,loaf,+ 18. An entity whoyhp1d lid taotractor s license under chapte9:28. RCWthaterploys a certified journeyman electrician,"a certified resi'd ntial specialty electrician, or an electrical trainee meetidg,tle requirements of chapter,19.28 RCW to perform plumbing work that is incidentally' directly,fand�tilnr�rlediately appropriate to the Iike = in'-ili. l:r21i1'acemeiit of a household • -NFe s appliance or other small `'housed tcliutilization equipment that requires limited electric power and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions.