Loading...
HomeMy WebLinkAboutPermit D12-340 - MONEYTREE - 3 OFFICES AND WORKROOMMONEYTREE 6720 FORT DENT WY D12 -340 City o±I'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Suite No: Project Name: MONEYTREE DEVELOPMENT PERMIT Permit Number: D12 -340 Issue Date: 01/04/2013 Permit Expires On: 07/03/2013 Owner: Name: JOHN C RADOVICH LLC Address: 2835 82ND AVE SE #300 , MERCER ISLAND WA 98040 Contact Person: Name: JENNIFER MUKAI Address: 909 112 AV NE, STE 206 , BELLE UE WA 98004 Contractor: Name: BAKER CONSTRUCTION Address: 2711 E SPRAGUE AVE , SPOKANE, WA 99202 Contractor License No: BAKERCD066CZ Lender: Name: Address: Phone: 425 641 -9200 Phone: Expiration Date: 04/08/2014 DESCRIPTION OF WORK: CREATING THREE OFFICES AND A WORKROOM WHERE THREE OFFICES EXIST NOW. WORK WILL INCLUDE CONSTRUCTION OF NEW WALLS TO CREATE THREE OFFICES WHERE A COPY ROOM NOW EXISTS. Value of Construction: $50,000.00 Fees Collected: $1,583.80 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: IIA Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12-340 Printed: 01 -04 -2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N 4 / 1/ I hereby certify that I have read and examined t giFermit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. Date: -( The granting of this pe construction or the perf to this permit. Signature: Print Name: does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating ance of we k. I am authorized to sign and obtain this development permit and agree to the conditions attached JC' Date: it 3 This permit shall becom - null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D12-340 Printed: 01 -04 -2013 7: All construction shall be done in conform with the approved plans and the requirem of the International Building Code or International Residential , International Mechanical Code, Washingtograte Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 25: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress doc: IBC -7/10 D12 -340 Printed: 01 -04 -2013 travel. Access to exits shall be marked by rly visible exit signs in cases where the exit o he path of egress travel is not immediately visible to the occ ts. Exit sign placement shall be such that no t in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, which er is less, from the nearest visible exit sign. (IFC 1011.1) 26: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 27: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 28: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot -candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 29: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 30: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 31: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 32: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 33: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2328) 34: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 35: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 36: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 37: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 38: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 39: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 40: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 41: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -340 Printed: 01 -04 -2013 •CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98/88 http://www.TukwilaWA.gov Building Permit No. tl 2' 0 Project No. Date Application Accepted: 10 VI-- Date Date Application Expires: ® lq 11 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: (f—1 )a �O!'� pettf- L Tenant Name: MANN Tree- PROPERTY OWNER Name: 'R2CACne(e. Address: .2000 I 3.4.4,‘ Ave_ Ne $cD_ City: p _ %leuve. State: up% Zip: 10615 CONTACT PERSON — person receiving all project communication t Name: 3 tv\ cei 1` A uke; Address: 03.i I I e p . Avt_ Address: glj'C t t a ^ J� w t 6 C Ate i /`�Zip:41 City: ji`wtuut_ State:lr V'Tr Contr Reg Nol2ttf i ( Exp Date:4De 113 Phone: [�1CCeJ~J . Log )4,, 1x: Email: ierNAN (ier' K.IJ% Coe_ r r(rd i J' GENERAL CONTRACTOR INFORMATION Company Name: 2 2 ver C LI,vC1tawl Address: 03.i I I e p . Avt_ City: [ O1, `^t. State: czo Zip: pbec !tom■ Phone: 583.535346Dx: Contr Reg Nol2ttf i ( Exp Date:4De 113 Tukwila Business License No.: H: \Applicauons \Forms - Applications On Lune\201 I Apphcauons\Penmt Application Revised - 8 -9 -1 Ldocx Revised: August 2011 bh Z King Co Assessor's Tax No.: 015 l l d - 045S Suite Number: 1 Floor: New Tenant: ❑ Yes cgt .. No ARCHITECT OF RECORD Company Name: 5 p / AtchI .fec5 Architect Name: tkerL Qa.er son Address: ¶ c n 144. /1., IV e gvrt e City:IR � `k�Ie i State: Lac Zip:1' (i Phone:` 4 64 vino Fax: JJ Email: 4_1) \Lit %LYV"frei.. iM-f Jr-- ENGINEER OF RECORD Name: Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206- 431 -3670 Valuation of Project (contractor's bid price): $ So, QQV Describe the scope of work (please provide detailed information): '' rr rr .eaf4 I tAi irto c1■1 ?ken-f ‘u ;1-& elftv.5 vsteu3 -Z I LC( L vvvnex At 4;A) - -(hv.ct c J t es 0k/1/4-eft - Cc 4 ( roots gace r-f N...) . Will there be new rack storage? ❑ Yes Existing Building Valuation: $ K].. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures,'plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentat4on that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes IK No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: f2 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes'. attach list of materials and storage locutions on a separate 8-1/2" x 11 "paper including quantities and Material Su" ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications \Forms - Applications On Line \2011 Applications\Pcrmit Application Revised - 8 -9 -1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per • IBC Type of Occupancy per IBC I51 Floor 1 j1 n I /� V C 11 k 8 2"'I Floor 4 3rd Floor IA Floors thru ANVA Basement � . WA Accessory Structure* N/A Attached Garage Detached Garage WA. Attached Carport IN Detached Carport .n Covered Deck w Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures,'plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentat4on that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes IK No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: f2 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes'. attach list of materials and storage locutions on a separate 8-1/2" x 11 "paper including quantities and Material Su" ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications \Forms - Applications On Line \2011 Applications\Pcrmit Application Revised - 8 -9 -1 I.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HA EAD AN " •THIS APPLI TION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY TH BUILDING OWNER OR ND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature: _. 7 Date: Print Name: .L S% "P Day Telephone: 4 • `41 • VW Mailing Address: qbelt It _Vl‘ % VatJV Q W I g$004 Zip H:\Applications \Forms - Applications On Line \2011 Applications\Permit Application Revised - 8 -9 -1 I,does Revised: August 2011 bh Page 4 of 4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Suite No: Applicant: MONEYTREE RECEIPT Permit Number: D12-340 Status: APPROVED Applied Date: 10/19/2012 Issue Date: Receipt No.: R13 -00035 Initials: User ID: TLS 1670 Payment Amount: $961.65 Payment Date: 01/04/2013 01:03 PM Balance: $0.00 Payee: MONEYTREE INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 227046 961.65 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 957.15 640.237.114 4.50 Total: $961.65 doc: Receiot -06 Printed: 01 -04 -2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Suite No: Applicant: MONEY TREE RECEIPT Permit Number: D12-340 Status: PENDING Applied Date: 10/19/2012 Issue Date: Receipt No.: R12 -02913 Payment Amount: $622.15 Initials: JEM Payment Date: 10/19/2012 11:55 AM User ID: 1165 Balance: $961.65 Payee: MONEYTREE, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 225755 622.15 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 622.15 Total: $622.15 rinr.• Rarpint -OR Printari. 1n_1Q_7n12 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 `n (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Yt_ Proje l{�v �✓t --� 1 re.� Type �ofrinspection: w_ Q tr�� r—, AJ A-k g,., , Address: / �_-- -- -DeAr Date Called: Special Instructions: Date Wanted • 2-c1 ( aa.m. Requester: Phone Nej:c 5. _3 IApproved per applicable codes. Corrections required prior to approval. COMMENTS: 7) Inspectors Date 2 �� n REINSPECTION FEE R WIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 r. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 D tZ -3d4o Projec n�f r. y c�vi!j jJC... -j--_, /� t r`eC�_ 'r: T ,� n ) Type of Inspection: 2 f-; m k.L. gu: 1.6.‘.A6.: Date Called: Add/rre --ss: to 7 ?4 Special Instructions: Date Wanted: 1 a.m } Requester: Phone No: . >'0o4 — 4'1.5 -2.43 Z aApproved per applicable codes. El Corrections required prior to approval. COMMENTS: � 11 Inspector: f � n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd..-Suite 100. Call to schedule reinspection. Date—ZL —/3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. c CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 p--- (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: A.o'U . 7c.(° Type of Inspection: r-.- .M..r(D • L. Co 1+-77-746 Address: ,'? (` ; _ __ -,r( .6e/Q-- Date Called: Special Instructions: (9---- Date Wanted:. ? /�a.m� Requester: Phone No: on 0 `9 A t? 5 —2-10 3 a Approved per applicable codes. Corrections required prior to approval. COMMENTS: r:-..o rr? c__.-t ;19/tJ M `t' Inspector:: 6`At1)/ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date e'` 7 j - -/ 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 D r 2 -YID Pro J a t: 1 (,,, e.-Y `t'rt_ e Type of Inspection: ..m .e r(o : L' (, l A( Date Called: Address_. '7.0 -112r( `� Special Instructions: Date Wanted:. / '"^,tn 3 .74 r- ! 3 p.m. Requester: Phone No: 5;01— 4'7.5 - 2 03 Z Approved per applicable codes. Corrections required prior to approval. , COMMENTS: Inspector: 11 Date:3 7/0 — /3 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION 'NO. INSPECTION RECORD Retain a copy with permit PERMIT +NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206)'431 -3670 Permit Inspection Request Line (206) 431 -2451 Proj ct: ----- iliA0A) f---y 1 re_e Type of Inspection: rs `t , - 6,, ... f: Addr ss --•- `i 249 rb -- r C De-AT Date Called: Special Instructions: t ci� / !/t) A-4'1-16-6 6 -i -Al. poi-- �y Date Wanted a.m.- Requester: �{l� Pho.p o: 75 --iata3 t ❑ Approved per applicable codes. D Corrections required prior to approval: COMMENTS: ( ) l at 646 A F - ( / ' � (/, u/ •`.J V'V f/ 1. 17 ! ./ r �. '(/ '� P c_ (. 9 `r k:A4 fr , c... -'' 4 111-71A `T' f �J r. 1-‘P L JAL 1 Inspector: VI Date: REINSPECTION FEE RtQUIRED. Prior to next inspection; fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule re' inspection: 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0: CITY OF TUKWILA BUILDING DIVISION: ; -':` 6300 Southcenter Blvd., #100, Tukwila: WA 98188 • '(206).431 =3670: Permit Inspection Request Line (206) 431 -2451 Project: V`Nnl.. ,(-11`04.:_i' Type of Inspection: • 5us��8N4f Ceti! t ;G Date Called: Address: _ (_;724 1- O T b011 LAI Special Instructions: � -- Date Wanted: •.I-- . ` t .- a m • pm. Requester: Phone No: -50Ci •-• .. 4-1-7'.772,0 72,0 3:.. Y Approved per applicable codes. COMMENTS: LJCorrections require&prior,to approval. in�pect . t`�,. Gtr .� I 'In A.....-.. ,C-A-k--1 Date -1,_- ! � -- ��:. ❑ RgI SPECTION FEE REQU J(ED. Prior to next inspection fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection INSPECTION RECORD — Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 `Al (206) 431' -3670 , Permit Inspection Request Line (206) 431 -2451 Pro'e t: ;) T Type ooff Ins`pec'ti(on: Address: - D Date Called: Special Instructions: D Date Wante : a ,�� � a.m. Requester: Phone No: 505-- 1 1).S- IApproved per applicable codes. El Corrections required prior to approval. COMMENTS: 1 / /1) t f7,1 tit 'Aid -- A l cNtc='d1 led./w) Inspect8 : Date: -�l A"""17 I .,. )c 1- z -i'1 n R INSPECTION FEE REQUIRED. Prior to n xt inspection fee Est be :. p i at 6300 Southcenter Blvd.. Suite 100. Call to schedule'reinspection:, n R INSPECTION FEE REQUIRED. Prior to n xt inspection fee Est be :. p i at 6300 Southcenter Blvd.. Suite 100. Call to schedule'reinspection:, :<CNSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY IJKWILA BUILDING DIVISION D(2% '6300 Southcenter BIvd ,' #100, Tukwila. WA 98188 (206) 431 -3670 Permit_Inspection °Request Line (206) 431 -2451 Prod ct: Type of.Inspection: A ki\ to 6-) Address:. �. '`=- Date Called: Special Instructions Date Wanted:. I 1— - f� ( ' .a.m. P.m. Requester: Phone No: n 2 Approved :per applicable codes. COMMENTS: ElCorrections required prior to approval. f /C_ ;r•_, Inspector: ( a 'T., I -.± ip .On' rit\ r Date: L - /3 REINSPECTION.PEE REQUIRED. Prior to next inspection, fee must be paid at 6300 . Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1S- nr 2 31D PERMIT NUMBERS. CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: ��� Sprinklers: Type Inspection: Ad ress: Lia,d Suite #. 7,,v A. t_, ,rj Contact Person: Special Instructions: Phone No.: VApproved per applicable codes. Corrections required prior to approval. COMMENTS: Sr: N/lt_ -oK -sp st e9g- -e., vtArz- --e5r Needs Shift Inspectioh: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ,,,5 Sa---- Date: 3 4///j J Hrs.: f $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: City: Word /Inspection Record Form.Doc Company Name: State: 6/11/10 Zip: T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Di?- ,5Yo /3- 5- - PERMIT NUMBERS. CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East. Tukwila, Wa. 98188 206-575-4407 Project: /VIP P9 (--Y-Q- e- Sprinklers: Type of Inspection: S e C-o v-e--- Address: to 7 c?..c.) Suite #: 13 0 c) r i -.5 - 1-e,-4- Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Ces Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: , Pre-Fire: Permits: Occupancy Type: Inspectorit A <--„)____- Date: /6// Hrs.: i $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address • Attn: Company Name: • Address': City: State: Zip: Word/Inspection Record Form.Doc T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit -S- 0.1O, ,DIa - 34/0 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: Ty Re of Inspection: p �jv --2�' /� ,, ,, MD i Y Address: Suite #: .54- Devil-- tS Contact Person: Special Instructions: . Typ: Phone No.: Approved per applicable codes. orrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: . Typ: 1 J �lS �� 5 s —t� --01, ep�: 5 #9►4 t i° I' l 9- / of et-5 Ory 'Apvv by -crS ov-(1. l " l ''v4- Lt-at Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: . Typ: Inspector: ez - . S-3-- Date: gii/ /,3 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspectioh. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 1 .2009 Washington State Energy Code Compliance Form for Nonresidential and:Multifamily Residential Inferior Lighting Summary LTG -INT 2009 Washington State Energy Code Compliance forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address 6720 FORT DENT WAY Date 10/19/2012 SUITE 230 For Building Department Use , _ FILE COPY ' !n{ry TUKWILA, WA 98188 Applicant Name: Jpc ARCHITECTS c Appliant Address: 909 112TH AVE NE, BELLEVUE Applicant Phone: 425 -641 -9200 Perri0.1101. Project Description ❑ New Building ❑ Addition ❑ Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option Q Prescriptive 0 Lighting Power Allowance 0 Systems Analysis ,(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allowed Watts per ft2 ** Gross Interior Area in ft2 Allowed x Area " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Proposed Lighting Wattage Location (floor plan /room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Notes: 1. For proposed Fixture Description, indicate fixture type, Tamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the er .._ age. REVIEWEEill GO R. Fo exempt lighting, note section and exception number, and leave Watts /Fixture blank. CODE COMPLIANCE APPROVED NOV 1 r 2012 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 19 2012 PERMIT CENTER 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary (back) LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised D Prescriptive Spaces Occupancy: Q Warehouse or Parking Garage QQ Other Qualification Checklist Note: If occupancy type is "Other" and fixture Lighting Fixtures: 0.85 Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. answer is checked„ the number of fixtures in `"` it i• e ' " " llI f the space is a',ohhmited by�Code.. • Cleariy� indicate these spaces-on`•pians. if•not qualified, do LPA Calculations. (Section 1521) * 1.10 1. Fluorescent fixtures with a) 1 or 2 two tamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8, or CFL ) lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 0.20 - -.. % 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA'Z (W /ftz) Use' LPAZ (W /ftz) Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments', restaurants /bars' 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 ootnotes for Table 15- 1) In cases in which a general use and a specific use are listed, the specific use shall apply. incases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w /ft2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within'2 feet of the window, provided that the display window is separated from the retail space by Walls or at least three- quarter- height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: :,-I y v;.(a)ILocated on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). i h ,,i, ; ;(b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). t 1 his additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for. any other purpose. rr ,. y 1 tt City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 31, 2012 Jennifer Mukai 909 112 Ave NE, Ste 206 Bellevue, WA 98004 RE: Correction Letter #1 Development Permit Application Number D12 -340 MoneyTree — 6720 Fort Dent Wy, Ste 130 Dear Ms. Mukai, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Fire Departments. Planning Department: Brandon Miles at 206 431 -3684 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. Sincerely, encl File No. D12 -340 W:\Permit Center\Correction Letters\2012\D12 -340 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PLANNING DIVISION COMMENTS DATE: October 24, 2012 CONTACT: JDC Architects RE: D12 -340 ADDRESS: 6720 Fort Dent Park ZONING: RCW Planning has reviewed the above building permit and the permit cannot be approved until the following is addressed: 1. Provide a breakdown of all uses on the site and show that the City's parking requirements will be met. PERMIT CO ORD Cal l\ PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -340 DATE: 11/07/12 PROJECT NAME: MONEYTREE SITE ADDRESS: 6720 FORT DENT WY, STE 130 Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division ❑ Public Works ❑ Fire Prevention Structural El -tr Al° 0-16-1-k • Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11/08/12 Complete M Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 12/06/12 Not Approved (attach comments) ❑ DATE: Permit Center.Use,Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: *PERMIT COORD COP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -340 DATE: 10/19/12 PROJECT NAME: . MONEYTREE SITE ADDRESS: 6720 FORT DENT WY, STE 130 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Bullding Division ) V\ \() Public Works Ate& 10.2��1� Fire Prevention Structural bA)18( ifoa • Planning Division Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10/23/12 Complete Incomplete ❑ Not Applicable ❑ Comments: Perm:t Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DUE DATE: 11/20/12 DATE: Permit Center Use Only CORRECTION LETTER MAILED: I O 99t I2 Departments issued corrections: Bldg ❑ Fire ❑ Ping IA PW ❑ Staff Initials: AV- • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 11/06/2012 Plan Check/Permit Number: D12 -340 r Response to Incomplete Letter # Response to Correction Letter # 6720 Revision # 1 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Moneytree A r nEC i ut NOV 0 7 20121 rtt M1Y cENTEA Project Address: 6720 Fort Dent Way, Ste 130 Contact Person: Jennifer Mukai Phone Number: (425) 641 -9200 Summary of Revision: The comments regarding the above permit application findings and our responses are found below: 1. Provide a breakdown of all uses on the site and show that the City's parking requirements will be met. Response: The scope of work sited was incorrect. It should have read as follows: 'Creating reconfiguring three offices and workroom where three offices exist now.' Moneytree is occupying the space now and is just moving a few walls around so we are not increasing the space so the parking will not be affected. An existing and proposed plan are attached to this document for your review. Please let us know if you have any additional concerns as we are happy to address them. Thanks in advance, Claire Wiese Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on tl 01 H:'Applicat ions \Fomts- Applications On Line \2010 Applications \7 -2010 - Revision Submittal.doc Revised: May 2011 Contractors or Tradespeople Pr, jeer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name BAKER CONSTRUCTION & DEV INC UBI No. 600163145 Phone 5095353668 Status Active Address 2711 E Sprague Ave License No. BAKERCD066CZ Suite /Apt. License Type Construction Contractor City Spokane Effective Date 2/9/1994 State WA Expiration Date 4/8/2014 Zip 99202 Suspend Date County Spokane Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company enses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status BAKERC*074CZ BAKER CONSTRUCTION Construction Contractor General Unused 2/9/1993 2/9/1994 Archived BAKERS "247CZ BAKER STEEL INC Construction Contractor General Unused 2/9/1976 2/9/1993 Archived Business Owner Information Name Role Effective Date Expiration Date BAKER, BARRY N Cancel Date 01/01/1980 Amount BAKER, DOUGLAS M 26 01/01/1980 4278119 GARBER. GEORGE J 03/31/2013 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 10 TRAVELERS CAS & SURETY CO 103544694 03/31/2002 Until Cancelled $12,000.00 01/22/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 26 American Guarantee & Liability 4278119 03/31/2012 03/31/2013 $1,000,000.00 03/30/2012 25 NATIONAL FIRE INSURANCE COMPAN 4013757137 03/31/2010 03/31/2012 $1,000,000.00 03/30/2010 24 NATIONAL FIRE INSURANCE COMPAN 4013757137 03/31 /2009 03/31 /2010 $1,000,000.00 03 /30/2009 23 NATIONAL FIRE INS CO OF HARTFO 2091646140 03/31/2008 03/31 /2009 $1,000,000.00 03/25/2008 22 ZURICH AMERICAN INS CO CP03697325 03/31/2006 03/31/2008 $1,000,000.00 03/19/2007 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 01/04/2013 U z CD 0 LJ 0 w cr 0 -0 0 Q 0 Q !C CD N N 0 Pen Table: JPC STD.CTB 16/2012 5:02 PM Moneytree 6720 Fort Dent Way, Floor 1, Suite 130 Phase 2 Site Plan Scale: NTS PLANNING APPROVED • No changes can be made to these plans without approval from the Planning Division of DCD Approved By: t S Date: \\—1 to -Ll REVISIONS No changes shall bo, mad^ to the scope c r vier approve.' of . yCut4ng Divisio:t_ rcgl h.e a am/plan submitt l . , may i av:ude ad onat plan review tees. 6ERVICE AREA 'TRASH ENCLOSURE ////. %7 Jai / /,/e% /, // i, COURTYARD F t 14.00 'E PERMIT I= Q J 1ED FOR: ! Ir'�ctricat bing �s Piping c.1 Tukwila '""1 DIVISION Fg E OPY Permit No. PIP!! rview approval is su : « to errors and o construction documents does not authr ":3 I_ :.):tics of any adopted code or ordinance. Rocs ;t By Date: I - 4-(3 City Of Tukwila BULLING DIVISION Sheet List Table Sheet Number Sheet Title I -0.0 I —CS.1 1 -1.1 I -3.1 1 -4.1 1 -8.1 1 -9.1 1 -10.1 Cover Sheet And Site Plan Exit Plan And Codes Summary Demolition And Dimension Plan Floor And Finish Plan Demo Reflected Ceiling Plan & Reflected Interior Elevations Construction Details Door Schedule Elevations Details Code Information: Ceiling Plan PROJECT ADDRESS: 6720 FORT DENT WAY SUITE 130 TUKWILA, WA 98188 CONSTRUCTION TYPE: CONST —TYPE IIA FULLY SPRINKLERED (NON QR) OCCUPANCY: B TENANT SQUARE FOOTAGE: (area of work) 1,459 SF Building Code Fire Code Energy Code Mechanical Code Electrical Code Plumbing Code 2009 INTERNATIONAL BLDG CODE (IBC), WAC 51 -50 2009 INTERNATIONAL FIRE CODE (IFC), INCL. APPENDIX B &C 2009 WASHINGTON STATE ENERGY CODE (WSEC), WAC 51 -11 2009 INTERNATIONAL MECHANICAL CODE (IMC), WAC 51 -52 JUNE 22, 2009 WA CITIES ELECTRICAL CODE, PARTS 1 & 3 AS PUBLISHED BY WA ASSOC. OF BLDG OFFICIALS 2009 UNIFORM PLUMBING CODE (UPC), WAC 51 -56 & 51 -57 INCL. APPENDIX CHAPTERS H & L — EXCL. SECTIONS L5 —L7 & "LAWN SPRINKLER HEAD" FROM TABLE 6 -4 OF APPENDIX L Zoning Code CITY OF TUKWILA Accessibility 2003 ACCESSIBLE & USABLE BUILDINGS & FACILITIES (ICC /ANSI A117.1) WAC 51 -50 -005 Code Legal Description: TAX PARCEL #295490 -0455 BEGINNING AT HIGHWAY ENGINEER'S STATION P.O.T. (2M) 127 +45.0 ON THE 2M LINE SHOWN ON THE STATE HIGHWAY MAP OF PRIMARY STATE HIGHWAY #1 (SR405) GREEN RIVER INTERCHANGE, SHEET 2 OF 4 SHEETS, ESTABLISHED BY COMMISION RESOLUTION #1192, FEBRUARY 19, 1962, THENCE NORTHEASTERLY AT RIGHT ANGLES TO SAID 2M LINE NORTH 30'27'06" EAST 218.36 FEET TO A POINT ON A LINE THAT IS PARALLEL WITH AND 140 FEET (MEASURED AT RIGHT ANGLES) NORTHEASTERLY OF THE SOUTHWESTERLY MARGIN OF VACATED KENNEDY STREET (6TH PLACE S.) AS SHOWN ON THE PLAT OF GUNDAKER'S INTERURBAN ADDITI01 LE, AS PER PLAT RECORDED IN VOLUME 14 OF PLATS, PAGE 46, RECORDS OF KING COUNTY, SAID POINT BEING THE TRUE POINT OF BEGINNING OF THE PARCEL TO BE DESCRIBED HEREIN, THENCE FROM SAID TRUE POINT OF BEGINNING ALONG SAID PARALLEL LINE NORTH 59'32'54" WEST TO THE BANK OF THE GREEN RIVER, THENCE ALONG THE BANK OF THE GREEN RIVER THE FOLLOWING COURSES: NORTH 38'19'12" EAST TO A POINT LYING SOUTH 30'04'58" WEST 334.53 FEET FROM THE SOUTHWESTERLY LINE OF THE ;ANDS CONVEYED TO KING COUNTY BY STATUTORY WARRANTY DEED RECORDED UNDER RECORDING NO. 7507300471 AND NORTH 30'04'58" EAST 334.53 FEET TO SAID SOUTHWESTERLY LINE, THENCE ALONG SAID SOUTHWESTERLY LINE SOUTH 59'24'45" EAST 183.62 FEET TO A POINT ON THE NORTHWESTERLY LINE OF THE LANDS CONVEYED TO THE CITY OF TUKWILA BY QUIT CLAIM DEED RECORDED UNDER RECORDING NO. 7410290105, THENCE ALONG LAST SAID NORTHWESTERLY LINE THE FOLLOWING COURSES: FROM A TANGENT THAT BEARS SOUTH 30'53'45" WEST ALONG THE ARC OF A CURVE TO THE LEFT HAVING A RADIUS OF 60.00 FEET AND A CENTRAL ANGLE OF 24'24'42 ", AN ARC LENGTH OF 13.63 FEET, THENCE TANGENT TO THE PRECEDING CURVE SOUTH 22'08'00" WEST 223.43 FEET, THENCE TANGENT TO THE PRECEDING CURVE SOUTH 30'27'06" WEST 66.52 FEET TO THE TRUE POINT OF BEGINNING, EXCEPT THAT PORTION CONVEYED TO THE CITY OF TUKWILA BY DEED RECORDED UNDER RECORDING NO. 7708040599, SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. Vicinity Map: PROJECT SITE EINED FOR COMPLIANCE PPROVED V l A 2012 _ Project Team: Property Owner of Tukwij UILDING DIVI&ON J.0 RADOVICH 2000 124TH AVE. NE., 8103 BELLEVUE, WA 98005 425 - 454 -6060 Tenant: MONEYTREE 6720 FORT DENY WAY TUKWILA, WA 98188 206 - 246 -3500 MEAGAN HENDERSON meagan .henderson @moneytreeinc.com Architect: JPC ARCHITECTS, PLLC 909 112TH AVE NE SUITE 206 BELLEVUE, WA 98004 (425) 641 -9200 MARK PETERSON — EXT. 340 markp @jpcarchitects.com CLAIRE WIESE — EXT. 351 clairew ®jpcarchitects.com General Contractor: BAKER CONSTRUCTION 2711 E. SPAGUE AVENUE SPOKANE, WA 99202 509 - 535 -3668 LIC. NO. #BAKERCDO6 ;tEvr,j crr' OF TUKY',”t OCT 192012 PERMIT CENTER t1Q-3L b 0 N VI w z tU N cr CD MoneyTree Floor 1 6720 Fort Dent Way Tukwila, WA 98188 DESIGN DRAWN CHECKED NO. JPC CCW MP 12 -0593 10 18 12 PFRMIT SUBMITTAL Cover Sheet and Site Plan I-0.0 © 2012, JPC Architects, PLLC Pen Table: JPC STD.CTB 10/8/2012 9:56 AM TOTAL DISTANCE 219' -9 3/8" OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE U I TRAVEL DISTANCE II :.. /'<\ ,OFFICE �',/ , y . 111 , - OFFICE k9ALL z' OFFIf 101 OFFICE OFFICE IT STORAGE OFFICE OFFICE OFFICE OFFICE OPEN OFFICE OFFICE RISER ROOM E EXIT 148' -1" EXIT SEPARATION (EXCEEDS MIN. DISTANCE REQUIRED) 1 D 0 1 Exit Plan _ Scale: 3/32 " =1' -0" 1) I.= 310 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 1 F 2012 City of Tukwila BUILDING DIVISION General Notes: Legend: Code Notes: N U LU ce U U a MoneyTree Floor 1 6720 Fort Dent Way Tukwila, WA 98188 1. MEANS OF EGRESS ILLUMINATION: THE MEANS OF EGRESS (EXIT PATHWAY) AND THE EXIT DISCHARGE DOOR SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING IS OCCUPIED AT AN ILLUMINATION LEVEL NOT LESS THAN 1 -FOOT CANDLE (10 LUX) AT THE WALKING SURFACE LEVEL PER IBC 1006. LIGHTING MUST BE PROVIDED WITH EMERGENCY BATTERY BACK -UP PER IBC 1006.3. "COMMON PATH OF EGRESS TRAVEL" IS LESS THAN 100' -0" (75' -0" FOR NO QUICK RESPONSE OR NON SPRINKLERED) AS ALLOWED FOR SPRINKLERED BUILDINGS WITH QUICK RESPONSE HEADS, PER 2006 IBC 1014.3, EXCEPTION #1. 4... —• ._ • "TOTAL EXIT ACCESS TRAVEL DISTANCE" IS LESS THAN 300' -0" (200' -0" FOR NO QUICK RESPONSE OR NON SPRINKLERED) AS ALLOWED FOR SPRINKLERED BUILDINGS WITH QUICK RESPONSE HEADS. DENOTES NUMBER OF OCCUPANTS 1. 65 TOTAL OCCUPANTS IN SUITE NUMBER 140: 65/3 = 22 PER EXIT. 2. EGRESS EXIT WIDTH: PER IBC SECTION 1005.1: 22 X 0.3 = 6.6 MINIMUM EXIT WIDTH. ACTUAL PROVIDED: 36 ". RhG :! v 1) CITY OF UK` .11.A OCT 19 2012 PERMIT CENTER DESIGN DRAWN CHECKED NO. JPC ccw MP 12 -0593 10 1R 12 PFRMIT StIRMITTAI Exit Plan and Codes Summary I-cs.1 © 2012, JPC Architects, PLLC Dwg: \ \KANDINSKY \PROJECTS\ 2012 \12 -0593 \DWG \WIP \MASTER \I -1.1 DEMOLITION AND DIMENSION PLAN .DWG m Pen Table: JPC STD.CTB 909 112th Avenue NE Suite 206 Bellevue, WA 98004 MoneyTree Floor 1 6720 Fort Dent Way Tukwila, WA 98188 DESIGN JPC DRAWN ccw CHECKED MP NO. 12 -0593 10 18 12 PFRMIT SUBMITTAL Demolition and Dimension Plan © 2012, JPC Architects, PLLC SCOPE OF WORK SCOPE OF WORK OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE 109 111 117 119 O I 123 124 125 126 HALL OP 1 / 1 I 0 • p • • 1/ 0- • 132 D I 1 1 rr (1 1 _ ° i n f z ALA 114 1 rr n u ' 3D OFFICE N \ '- 10' -0" EQUAL 1 , 1 1 o I r>T D 41 �• I 103 03 © P OFFICE IIIIIIIIIIIIII OFFICE IT STORAGE OFFICE EQUAL HA' 13 _ ll / - / �0s %� I 113 121 OFFICE OFFICE o 105 T 133 134 OFFICE E r J , I W � I 4 135 1• .� rn HALL _ _ _ / z 104 12' -11 1/2" O o ©, H:4 d TYP 11 TYP o O o I z 10' -1" � 11' -7" 4' -0" la o u = �I . CLR OFFICE : I O ` •' o Il -� -� �I• ��• - _ 102 i2 _ o © 106 •M -�— 11 �. L t• 7 -5 OFFICE . ♦ - 1I STORAGE O � I 4- D \ 107 d % .4 0 8'-4 1 2" V N C� LR . � \ ❑ ❑ \; ., / �, • 100 e ; ■ [0) G / y ' 7 •• , \ ./ • � o Dimension Plan I \\ , Demo » �. \ \ Plan vScale: 1/8 " =1' -O" Scale: 1/8 " =1' -0" Demo Plan General Notes: Key Notes: Dimension Notes: Partition Legend: 1 • COMPLY WITH ALL RULES AND REGULATIONS OF GOVERNMENTAL AUTHORITIES HAVING JURISDICTION OVER DEMOLITION WORK. 2. DEMOLITION INCLUDES COMPLETE REMOVAL AND DISPOSAL OF DEMOLISHED ITEMS. RETAIN SALVAGEABLE ITEMS WHERE OR WHENEVER APPROPRIATE. COORDINATE STORAGE WITH OWNER OR REUSE ON PROJECT. 3. NOTIFY ARCHITECT IMMEDIATELY OF ANY CONFLICTS BETWEEN EXISTING CONDITIONS AND NEW CONSTRUCTION PRIOR TO PROCEEDING WITH THE WORK. 4. REMOVE, REPLACE AND RELOCATE EXISTING MECHANICAL, ELECTRICAL AND FIRE PROTECTION EQUIPMENT /DEVICES AS REQUIRED FOR NEW CONSTRUCTION. AT LOCATIONS WHERE ELECTRICAL IS TO BE REMOVED, PULL OUT WIRING BACK TO PANEL. SEE DESIGN BUILD MECHANICAL, ELECTRICAL AND COMMUNICATIONS DRAWINGS FOR ADDITIONAL INFORMATION. 5. PROTECT STRUCTURAL ELEMENTS FROM DAMAGE DURING CONSTRUCTION. 6. PRIOR TO START OF WORK, COORDINATE WITH TENANT THE SCHEDULE FOR SHUTOFF, CAPPING AND /OR CONTINUATION OF UTILITY SERVICES REQUIRED. 7. EXISTING DOORS, FRAMES AND HARDWARE SCHEDULED TO BE REMOVED SHALL BE SALVAGED AND RELOCATED TO OWNER STORAGE OR REUSE WHERE OR WHENEVER APPROPRIATE. 8 PATCH AND REPAIR EXISTING WALLS AT DEMOLISHED AREAS TO A "LIKE -NEW" APPEARANCE. 0 NO WORK IN THIS AREA UNLESS OTHERWISE INDICATED. REFER TO FLOOR AND FINISH PLAN FOR ADDITIONAL INFORMATION. 2 DEMOLISH EXISTING PARTITION WALLS (PARTIAL, GRID HEIGHT & FULL O HEIGHT) PROTECT EXISTING ADJACENT SURFACES, INCLUDING BUT NOT LIMITED TO CEILING, ADJACENT WALLS AND FLOORING. REFER TO FLOOR PLAN FOR ADDITIONAL INFORMATION. DEMOLISH AND DISPOSE OF EXISTING CABINETRY. PATCH AND REPAIR AFFECTED AREAS, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS AND CEILINGS AS REQUIRED MATCHING EXISTING FINISH MATERIALS, U.N.O ® DEMOLISH AND RE -USE EXISTING DOORS, FRAMES, SIDELITES AND HARDWARE WHERE APPLICABLE. 50 DEMOLISH ELECTRICAL, LOW VOLTAGE AND LIFE SAFETY EQUIPMENT /DEVICES (INCLUDING LOW VOLTAGE CABLING) NOT USED AND AS REQUIRED FOR NEW CONSTRUCTION. © DEMO EXISTING THERMOSTAT RELOCATE AS REQUIRED. 7 PATCH AND REPAIR AFFECTED SUBSTRATE AS REQUIRED FOR INSTALLATION 0 OF NEW PARTITION. HATCH INDICATES FINISH FLOORING AND BASE TO BE DEMOLISHED. PATCH O AND REPAIR AFFECTED SUBSTRATE AS REQUIRED FOR INSTALLATION OF NEW FINISH FLOORING AND BASE MATERIALS. REFER TO FLOOR / FINISH PLAN FOR ADDITIONAL INFORMATION. gO DEMOLISH AND DISPOSE OF EXISTING PLUMBING /FIXTURES. TERMINATE AND CAP ALL EXISTING SUPPLY /WASTE LINES BEHIND WALL AND /OR FLOOR. PATCH AND REPAIR AFFECTED AREAS, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS AND CEILINGS AS REQUIRED MATCHING EXISTING FINISH MATERIALS, UNO 10 ELECTRICAL CHASES AND PANELS TO BE RELOCATED. 11 RELOCATE EXISTING FEC. 12 REUSE EXISTING RATED DOOR PER FLOOR PLAN. 1. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS GOVERN. ALL PARTITION LOCATIONS SHALL BE AS SHOWN ON PARTITION PLAN. IN CASE OF CONFUCT NOTIFY ARCHITECT. PARTITION PLAN BY ARCHITECT TAKES PRECEDENCE OVER ALL OTHER PLANS. 2. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE OF GYPSUM BOARD TO FINISH FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ALL DIMENSIONS MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESSES OF ALL WALL FINISHES, U.N.O. 3. DIMENSIONS NOTED "CLEAR" OR "CLR" MUST BE ACCURATELY MAINTAINED, AND SHALL NOT VARY MORE THAN ± 1/8" WITHOUT WRITTEN INSTRUCTION FROM ARCHITECT. 4. DIMENSIONS MARKED ± MEAN A TOLERANCE NOT GREATER NOR SMALLER THAN 2 INCHES FROM INDICATED DIMENSION, U.N.O. VERIFY FIELD DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. SECURE ARCHITECT'S APPROVAL. . 5. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES OR CONFLICTS IN THE LOCATION(S) OF NEW CONSTRUCTION. UPON COMPLETION OF PARTITION LAYOUT, NOTIFY ARCHITECT. VERIFICATION OF THE LAYOUT TO BE PROVIDED BY THE ARCHITECT PRIOR TO PARTITION INSTALLATION. 6. REFER TO REFLECTED CEILING PLANS FOR SOFFITS, CEILING HEIGHTS AND PLENUM BARRIER LOCATIONS. 7. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. U.N.O. 8. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. 9. ALL DOORS SHALL HAVE 1' -6" CLR. ON STRIKE /PULL SIDE AND 1' -0" CLR. ON PUSH SIDE OF DOOR. VERIFY AND ADVISE ARCHITECT OF EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. = _ = EXISTING PARTITION TO BE REMOVED • 3 Ra $ ID 1EWEED FOR CODE COMPLIANCE APPROVED NOV 112 City of Tukwila BULL IN D1V1S EXISTING PARTITION /CONSTRUCTION TO REMAIN GRID HEIGHT PARTITION. REFER TO DETAIL 3/1-9/1. RATED PARTITION. REFER TO DETAIL 4/1 -9/1. NOTE: AT LOCATIONS AS NECESSITATED BY POCKET DOOR SYSTEMS, "IN -WALL" ELECTRICAL AND /OR MECHANICAL SYSTEMS PROVIDE APPROPRIATE METAL STUD WIDTH TO ACCOMMODATE SIZING REQUIREMENT. CONFORM TO SPECIFIED METAL GAUGE AND SPACING AS INDICATED BY WALL TYPE. REFER TO CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. P'tri-L Key Notes: @ NO WORK THIS AREA. O AT LOCATIONS AS NECESSITATED BY "IN -WALL" ELECTRICAL AND /OR MECHANICAL SYSTEMS, PROVIDE APPROPRIATE METAL STUD WIDTH TO ACCOMMODATE SIZING REQUIREMENT. CONFORM TO SPECIFIED METAL GAUGE AND SPACING AS INDICATED BY WALL TYPE. REFER TO CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. O FURR WALL AT INTERIOR AS REQUIRED FOR NEW ELECTRICAL PANEL. Rit t!vz.J CITY OF T�PK\A " A OCT 19 2012 ERN"' CENTER 909 112th Avenue NE Suite 206 Bellevue, WA 98004 MoneyTree Floor 1 6720 Fort Dent Way Tukwila, WA 98188 DESIGN JPC DRAWN ccw CHECKED MP NO. 12 -0593 10 18 12 PFRMIT SUBMITTAL Demolition and Dimension Plan © 2012, JPC Architects, PLLC FLOOR AND FINISH PLAN.DWG r0 CC 0, w U 0 0, 0 w 0 CC CL Z 0 Y / / CO a a) )C JPC STD.CTB a I a° N F- U w F- U ce .11 V 909 112th Avenue NE Suite 206 Bellevue, WA 98004 MoneyTree Floor 1 6720 Fort Dent Way Tukwila, WA 98188 DESIGN JPC DRAWN ccw CHECKED MP NO. 12 -0593 10 1R 12 PFRMIT SUBMITTAL Dimension and Floor Plan 1-3-1 © 2012, JPC Architects, PLLC SCOPE OF WORK 111 -_I i OFFICE i OFFICE . OFFICE _ L n OFFICE I a� J, .t— SCOPE OF WORK OFFICE E 01117E OFFICE OFFICE OFFICE OFFICE 109 111 117 119 OFFICE - =- OFFICE OFFICE 0- 123 C. 124 GI 125 126 109 119 OFFICE 1 126 JL4L1L11 +42 +42 I 123 124 125 ,111 -r...=Th SCOP� HALL �� 132 I I- I •1 I 111 111 � 114 ,� , HALL SC___ OP F W RK 132 OFFICE Deco _ _ F.E.C. �� rl z_ " n ,y II ' ' " ( 114 w N N 1 v „ H n n OFFICE . _ D OFFICE IT STORAGE OFFICE \ HALL © ;OFFICE Q ; 0 1 �•'' OFFICE °�Z 113 E 121 131 103 - Q (� l�1 O -lyp �i N II ` 105 .,E OFFICE OFFICE IT STORAGE OFFICE OFFICE OFFIC� RBID HA 12 P Gz N ;;; +�� 133 I 134 II �' w OFFICE 121 105 113 11� !— ® �V 4 ' 135 �i� N ( 133 ( 134 1 ` HALL ��� OFFICE ® Q 104 ► i 1 MOM IU O 1.4 135 +44 "= :: � HALL 0 �' Z ∎ 104 O O u OFFICE _- I- I O p �' O I 0 102 . r ! o i-li OFFICE - n I ell 102 i—li __ OFFICE , os =- �, r- N pn. OFFICE F.E.C. OFFICE L 101 I_ 106 0710 [� STORAGE j / N •,_ N l N ©Np 107 • OFFICE �- I 101 STORAGE GE ■; _ F.E.C. Q ��i� v _ _ .0 ,_�h(B tl 'i• ` -E COPY Rv1 1 ���� / I 100 � '� I .0 :[ °)t - N +411 ( ° ..424 I -8.1 ���® �.�: -_ 111 i P IP ��� c° \ j / \ ....04" is--*' ••� ., %+ j ....„.., \ • Li \ � \\ ' Floor Plan —_ \ % I I 11 4116) I p " III Plan Scale: 1/8 " =l' -0" V 4# Scale: 1/8 " =1' -0" Floor Plan General Notes: Floor Plan Key Notes: Finish Plan General Notes: Finish Specifications 1. FLOORING TO BE CARPET (Cl) DIRECT GLUE DOWN UNLESS OTHERWISE NOTED. FOLLOW CRI GUIDELINES FOR INSTALLATION. 2. WALLS TO RECEIVE 4" HIGH RUBBER BASE RBI, THROUGHOUT UNLESS NOTED OTHERWISE. 3. WALLS TO RECEIVE P1 THROUGHOUT UNLESS NOTED OTHERWISE. 4. FOLLOW MANUFACTURER PROVIDED DETAILED INSTALLATION GUIDELINES & USING MFG. RECOMMENDED ADHESIVE PRODUCT OR TOOLS AS REQUIRED. PROVIDE TENANT WITH MANUFACTURER RECOMMENDED CARE AND MAINTENANCE INSTRUCTIONS. 5. BUILDING STANDARD DOORS THROUGHOUT UNLESS NOTED OTHERWISE. 6. SUBMIT SAMPLES TO DESIGN ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. O NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. REFER TO FLOOR /FINISH PLAN FOR ADDITIONAL INFORMATION. O 2 POWER /COMMUNICATIONS PACKAGE (WALL) WITH (1) SINGLE GANG MUD RING (WITH PULL STRING) AND (1) 110V DUPLEX. VERIFY EACH SPECIFIC PACKAGE FOR SPECIAL REQUIREMENT DESIGNATION. D = DEDICATED CIRCUIT; IG = ISOLATED GROUND WITH FULL -SIZE NEUTRAL; DIG = DEDICATED CIRCUIT WITH ISOLATED GROUND AND FULL -SIZE NEUTRAL. ALL HORIZONTAL DATA /COMMUNICATIONS PATHWAYS IN INSULATED WALLS SHALL BE RUN IN CONDUIT OF APPROPRIATE SIZE. CONFIGURATION TO MATCH EXISTING BUILDING STANDARD. REUSE AND REINSTALL EXISTING SALVAGED ELECTRICAL AND LOW VOLTAGE SYSTEMS (CABLING, DEVICES AND EQUIPMENT) WHERE OR WHENEVER PRACTICAL (AS APPROVED BY TENANT). REFER TO GENERAL NOTES AND ELECTRICAL DESIGN -BUILD DOCUMENTS FOR ADDITIONAL INFORMATION. , NEW FIRE EXTINGUISHER CABINET (F.E.C.). MOUNT AT 48" A.F.F. TO CENTER. PROVIDE IDENTIFICATION SIGNAGE AT EACH EXTINGUISHER LOCATION AS REQUIRED. CONFORM TO BUILDING STANDARD FOR MANUFACTURER (CABINET /BOTTLE) TYPE AND STYLE. C4.- ANCILLARY FURNITURE FIXTURES AND EQUIPMENT. TENANT FURNISHED AND INSTALLED. INCLUDING BUT NOT LIMITED TO CHAIRS, TABLES, DESKS, AND FILE CABINETS. O NOT USED. 6 WHERE WALLS HAVE BEEN DEMOLISHED PATCH AND REPAIR WALL. PAINT FINISH TO MATCH EXISTING ADJACENT SURFACE 07 EXISTING COLUMNS TO REMAIN. PROVIDE MINI BLINDS AT SIDELITES THROUGHOUT SCOPE OF WORK. ® MATCH EXISTING. O NEW COPIER /PRINTER LOCATION. PROVIDE DEDICATED POWER WITH (1) SINGLE GANG MUD RING (WITH PULL STRING). 10 RELOCATED ELECTRICAL PANEL NOTE: AT LOCATIONS AS NECESSITATED BY POCKET DOOR SYSTEMS, "IN -WALL" ELECTRICAL AND /OR MECHANICAL SYSTEMS PROVIDE APPROPRIATE METAL STUD WIDTH TO ACCOMMODATE SIZING REQUIREMENT. CONFORM TO SPECIFIED METAL GAUGE AND SPACING AS INDICATED BY WALL TYPE. REFER TO CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. 1. ALL AREAS TO RECEIVE RB -1 U.N.O. 2. ALL WALLS & PARTITIONS TO RECEIVE P -1 U.N.O. 3. PREP ALL EXISTING FLOOR SURFACES TO RECEIVE NEW FINISHES AS SCHEDULED. 4. PROVIDE PAINT APPLICATION APPROPRIATE TO THE SUBSTRATE TO WHICH IT IS TO BE APPLIED. SURFACES BD 5 . ALL EXPOSED GYP. BD. BOTH EXISTING AND NEW, ARE TO RECEIVE NEW PAINT FINISH. PREP ALL SURFACES AS REQUIRED FOR NEW PAINT FINISH. PROVIDE ONE PRIME COAT PLUS TWO FINISH COATS 6. CHANGES IN FLOOR MATERIALS THAT OCCUR AT FRAMED DOOR OPENINGS SHALL OCCUR AT THE CENTERLINE OF THE DOOR IN THE CLOSED POSITION. 7. ANY DECORATIONS USED SHALL BE NON- COMBUSTIBLE OR FLAME - RETARDANT TREATED IN AN APPROVED OF MANNER (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) 8. ALL INTERIOR PARTITIONS, CEILING FINISHES AND TRIM OF PUBLIC AREAS TO COMPLY WITH CLASS 1 MATERIAL CLASSIFICATION; FLAME SPREAD RATING 0 TO 25, SMOKE DEVELOPED 200. ALL INTERIOR WALL AND CEILING FINISHES AND TRIM OF NON- PUBLIC AREAS TO COMPLY WITH CLASS 2 MATERIAL CLASSIFICATION; FLAME SPREAD RATING 26 TO 75, SMOKE DEVELOPED 450. 9. FLOOR COVERINGS OF PUBLIC AREAS TO MEET CLASS A INTERIOR FLOOR FINISH REQUIREMENTS; CRITICAL RADIANT FLUX OF 0.45 WATTS PER SQUARE CENTIMETER OR HIGHER, FLOOR COVERINGS OF NON- PUBLIC AREAS TO MEET CLASS B INTERIOR FLOOR FINISH REQUIREMENTS; CRITICAL RADIANT FLUX BETWEEN 0.22 WATTS PER SQUARE CENTIMETER AND 0.44 WATTS PER SQUARE CENTIMETER. 10. CARPET INSTALLATION TO MEET THE GUIDELINES OF THE CARPET AND RUG INSTITUTE -CRI CARPET INSTALLATION STANDARD - CURRENT EDITION. 11. PROVIDE FINISHED SCRIBE STRIPS AND FINISHED MILLWORK EDGES TO CREATE A FINISHED REVEAL CONDITION WHERE MILLWORK COUNTERS, CABINETS, ETC. "ABUT" ADJACENT PARTITION CONSTRUCTION. ALL EXPOSED REVEAL SURFACES AND EDGES TO HAVE SAME PLASTIC LAMINATE FINISH AS THE CASEWORK ITEM THEY "ABUT ". 12. CONTRACTOR TO CLEAN AND REPAIR ALL EXISTING EXTERIOR GLAZING AND INTERIOR RELITE MINI - BLINDS WITHIN THE WORK AREA. FLOORING ._ 1 3 , D REVIEWED FOR CODE COMPLANCE APPROV D NOV 1 R 2012 City of Tukwila BUILDING DIVISION RECCb.vto�, CITY OF TUK4 I OCT 19 2012 PERMIT CENTER CPT 1 BASE TYPICAL FLOORING, U.N.O. MFR: TBD STYLE NAME: TBD STYLE NO: TBD COLOR NO: TBD BACKING: TBD INSTALLATION: TBD MFR REP.: TBD RB1 TYPICAL BASE, U.N.O. MFR: TBD PRODUCT: TBD COLOR NAME: TBD COLOR NO: TBD ASTM TYPE: TBD PROFILE: TBD 9 GENERAL WALL PAINT (TYPICAL U.N.O.) F .C. o .E BUILDING STANDARD FIRE EXTINGUISHER CABINET DUPLEX RECEPTACLE 4i DEDICATED DUPLEX RECEPTACLE GFI DUPLEX RECEPTACLE 4) FOURPLEX RECEPTACLE 4111 DEDICATED FOURPLEX RECEPTACLE -0 SPECIAL RECEPTACLE Q CORE DRILL Q J -BOX FOR TENANT PROVIDED SYSTEMS FURNITURE. POWER POLE , VOICE /DATA RECEPTACLE. CONTRACTOR TO PROVIDE MUD RING AND PULL STRING CO PROXIMITY CARD READER <8>-• WALL TAG NO DESIGNATION = EXISTING N = NEW 8c/OR RELOCATED (COORDINATE RELOCATED ITEMS W /ARCHITECT) D = DEMOLISH Partition Le end: SHERWIN WILUAMS PRO MAR 2000 0 MFR: TBD EXISTING PARTITION TO BE REMOVED — — EXISTING PARTITION /CONSTRUCTION TO REMAIN 0 COLOR NAME: TBD COLOR NO: TBD SHEEN: EGGSHELL, SEMI -GLOSS ® WET AREAS ACCENT WALLS GRID HEIGHT PARTITION. REFER TO DETAIL 3/1 -9/1. RATED PARTITION. REFER TO DETAIL 4/1 -9/1. D MFR: TBD © COLOR NAME: TBD COLOR NO: TBD SHEEN: EGGSHELL, SEMI -GLOSS ® WET AREAS WINDOW COVERING yy1 BUILDING STANDARD COLOR: TBD INSTALLATION: INSTALL TO MATCH EXISTING Finish Plan Key Notes: O NO WORK IN THIS AREA O HATCH AREA INDICATES EXTENT OF CARPET, BASE AND PAINT TO MATCH BUILDING STANDARD. N F- U w F- U ce .11 V 909 112th Avenue NE Suite 206 Bellevue, WA 98004 MoneyTree Floor 1 6720 Fort Dent Way Tukwila, WA 98188 DESIGN JPC DRAWN ccw CHECKED MP NO. 12 -0593 10 1R 12 PFRMIT SUBMITTAL Dimension and Floor Plan 1-3-1 © 2012, JPC Architects, PLLC DEMO REFLECTED CEILING PLAN & REFLECTED CEILING PLAN.DWG Author: CLAIRE WIESE Date/Time: 10/18/2012 8:53 AM 909 112th Avenue NE Suite 206 Bellevue, WA 98004 MoneyTree Floor 1 6720 Fort Dent Way Tukwila, WA 98188 DESIGN JPC DRAWN ccw CHECKED MP NO. 12 -0593 10 18 12 PFRMIT SUBMITTAL Demo Reflected Ceiling Plan & Reflected Ceiling Plan I -4.1 © 2012, JPC Architects, PLLC Akammow SCOPE OF WORK • — SCOPE OF WORK I \ \ \ ( -(f)- .1.- I , I �iII Q-YP DI dC ®0F WK �1- �I -.1 — I II I \ I I y I r �, F.E.C. .__.I__��_. — r gli ■■ II I� I G IIIIM © N ■ - I kD, I�'r1 r vQ r . D kD1 I to ■L L It Ly- d_ t L N 1`L �L ■ ■_! r IL J ____ O ■� N N w I� ' V I _ x - k1 k1 ,.' I 1 •Im 'u Nil 0 �■ DI i1 I J i R t• QTYP . :tiitar —‘, D N ■ 111 F I I F .0 O r ,— I r 1 1 .0E1 VII MN ° N ,..._. ;. ■� \ j /� /© I1., N I� - mil z,- / 5711 7 r A v11 511 LMIIPP" _A.l■ /� la III ■II __ ■ ■Pr" I►111 ■ ■ ] lit l■ I ■v __ ■LI _ _ \ __ ■ \\1r� �� , / .AMEN ■IP' 41 _ ■�PM . AU•__•LUIi• AMEN / ��—� ,, I��U ■� ■ ■�' ■� ■MI\ r - 1 ■ ■ ■� ■ �� /II ■!t \ 1 ■■■■U�■iI ■!!!■�■�\ z \ �m ■ ■��M %■ ■PEE\ \ �- �, ■i ■1 ■ ■■� / ■ ■ /EM\ \�■ 1 .— N \ a o 1 �� I1 ik.) Demo Reflected Ceiling Plan (I Reflected Ceiling Plan r V IScale: 1/8 " =1' -0" Mir, Scale: 1/8 " =1' —O" Reflected Ceiling Notes: Key Notes: RCP Key Notes: . COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO ENSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEM, ETC., NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED ON ARCHITECT'S DRAWINGS. 2. PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO VERTICAL SURFACES, FREE FROM CURVES, BREAKS OR OTHER IRREGULARITIES AND PAINTED TO MATCH CEILING FINISH. 3. FURNISH AND INSTALL ALL ASSOCIATED TRIM AND SEISMIC BRACING AS REQUIRED. 4. LIGHT FIXTURES, NEW SPRINKLERS AND OTHER CEILING ELEMENTS SHALL BE CENTERED IN THE 2'X2' SECTION OF INDIVIDUAL CEILING TILES U.N.O. (EXIST. SPRINKLERS TO REMAIN UNLESS CONFLICT WITH NEW ELEMENTS). 5. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE, AND MATCH ADJACENT CEILING FINISH U.N.O. 6. ALL SOFFITS AND CEILING HEIGHTS ARE DIMENSIONED FROM TOP OF FINISHED FLOOR TO BOTTOM OF FINISHED GYPSUM BOARD OR CEILING TILE AND SHALL ALLOW FOR THICKNESS OF ALL FLOOR FINISHES. 7. THE REFLECTED CEILING PLAN INDICATES THE LOCATION OF CEILING HEIGHTS, LIGHT TYPES, LIGHT FIXTURES, AND ASSOCIATED ITEMS. 8. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION FOR VARIOUS ABOVE- CEILING ELEMENTS ARE TO BE DESIGN BUILD, DOCUMENTATION BY OTHERS - PERMITTED SEPARATELY. 9. NOTIFY ARCHITECT OF ANY CONFLICTS OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, STRUCTURES, HVAC, AND /OR (E)CONDUIT, PRIOR TO FRAMING FOR LIGHTS. ANY DISCREPANCIES BETWEEN ARCHITECT'S CEILING GRID LOCATION & ACTUAL FIELD CONDITIONS ARE TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO FRAMING. 10. SUBMIT GRILLE, THERMOSTAT, AND OTHER FIXTURE AND ELEMENT LAYOUTS TO THE ARCHITECT FOR REVIEW AT LEAST 2 WEEKS PRIOR TO INSTALLATION. 11. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, MECHANICAL DUCTS, STRUCTURAL ELEMENTS AND ALL OTHER RELATED ITEMS. INSTALL NEW PLUMBING, MECHANICAL, FANS, DUCTS, CONDUITS, AND OTHER RELATED ITEMS SO AS TO NOT CONFLICT WITH ANY /ALL FIELD CONDITIONS INCLUDING LUMINAIRES. 12. INSTALL NEW LIGHT FIXTURES WITH PROTECTIVE FILM OR SIMILAR COVER OVER LOUVER, LENS, BAFFLE, ETC. TO AVOID FIXTURE SOILING OR DAMAGE. FIXTURES SHALL BE MAINTAINED CLEAN AND AS NEW. ALL LAMPS SHALL BE NEW AT PROJECT COMPLETION - RELAMP EXISTING FIXTURES. 14. CONTRACTOR TO VERIFY CODE COMPLIANCE OF ALL EXISTING LIGHTING FIXTURES AND ASSOCIATED SEISMIC BRACING RESTRAINTS. FIXTURES FOUND NOT IN COMPLIANCE SHALL BE MODIFIED AND /OR NEW PROVIDED AS REQUIRED BY CURRENT BUILDING AND /OR ENERGY COMPLIANCE CODES. 15. ALL EXITING LIGHTS AND EGRESS LIGHTING LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE INSPECTOR'S FIELD PLACEMENT DETERMINATION. 16. ALL SMOKE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITH IMC /IBC OR SUPERCEDING CODE. ALL FIRE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITH IMC /IBC OR SUPERCEDING CODE. @1 NO WORK IN THIS AREA UNLESS OTHERWISE INDICATED. REFER TO FLOOR AND FINISH PLAN FOR ADDITIONAL INFORMATION. 2 HATCH INDICATES EXTENT OF EXISTING GWB CEILING AND HEADER TO BE DEMOLISHED. INFILL TILE AND GRID TO MATCH EXISTING. O CROSS HATCH INDICATES THE EXTENT OF EXISITNG GRID AND TILE TO BE DEMOLISHED. REFER TO REFLECTED CEILING PLAN FOR LAYOUT. ® NOT USED O SALVAGE AND REUSE EXISTING LIGHTS. REUSE WHERE APPLICABLE. REFER TO REFLECTED CEILING PLAN FOR NEW LAYOUT. MODIFY EXISTING ELECTRICAL, MECHANICAL AND LIFE SAFETY SYSTEMS AS © REQUIRED BY SCOPE OF NEW WORK, MOST CURRENT ISSUE OF APPLICABLE BUILDING CODES AND DESIGN /CONSTRUCTION STANDARDS FOR < BUILDING NAME> INCLUDING, BUT NOT LIMITED TO CIRCUITING, SWITCHING, DUCTING (SUPPLIES /RETURNS), BALANCING, SPRINKLER HEAD AND /OR HORN /STROBE 1. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS ARE GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT THE GUARANTIES OF ACCURACY, THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS. 2. REFER TO SHELL AND CORE DRAWINGS FOR STAIR AND CORE ROOM INFORMATION. 3, MECHANICAL, ELECTRICAL AND LIFE SAFETY ARE SHOWN BASED ON INFORMATION PROVIDED BY OTHERS AND IS TO BE USED FOR COORDINATION PURPOSES ONLY. 4 PROVIDE FIRE RATED GROUTING OR SAFING AT ALL CEILING PENETRATIONS AS REQUIRED TO MAINTAIN FIRE RATING REQUIREMENTS. COORDINATE WITH ARCHITECTURAL, MECHANICAL AND ELECTRICAL DOCUMENTS. 5. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR ADDITIONAL CEILING EXIT SIGNS PENDING CITY INSPECTION REQUIREMENTS. 6. AS REQUIRED ALL SMOKE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITH UBC 713.10 AND ALL FIRE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITH UBC 713.11. 7. EXIT ILLUMINATION LIGHTS WILL HAVE EMERGENCY BACK -UP POWER PER 1997 UBC. 8. ITEMS NOTED BY "D" ARE TO BE REMOVED. ITEMS NOTED BY "N" ARE NEW. ITEMS NOTED BY "R" ARE RELOCATED. ITEMS WITHOUT NOTATION ARE EXISTING. O NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. REFER TO FLOOR /FINISH PLAN FOR ADDITIONAL INFORMATION. 2 INFILL 2X4 BUILDING STANDARD CEILING TILE AND GRID. REFER TO SPECIFICATIONS ON SYMBOLS LEGEND. 3 HATCH AREA INDICATES INFILL OF GYPSUM WALL BOARD CEILING TO MATCH EXISTING CONSTRUCTION METHODS TECHNIQUES, RATINGS AND FINISHES AS REQUIRED. REFER TO DETAIL 12/1 -9.1 FOR ADDITIONAL INFORMATION. ® ALL EXITING LIGHTS AND EGRESS LIGHTING LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE INSPECTOR'S FIELD PLACEMENT DETERMINATION. MODIFY EXISTING ELECTRICAL, MECHANICAL AND LIFE SAFETY SYSTEMS AS REQUIRED BY SCOPE OF NEW WORK, MOST CURRENT ISSUE OF APPLICABLE BUILDING CODES AND DESIGN /CONSTRUCTION STANDARDS, BUT NOT LIMITED TO CIRCUITING, SWITCHING, DUCTING (SUPPLIES /RETURNS), BALANCING, SPRINKLER HEAD AND /OR HORN /STROBE RELOCATION. NOTE: IT IS THE INTENT THAT ALL ABOVE CEILING SYSTEMS BE INVESTIGATED PRIOR TO BID SUBMISSION AND THAT SAID SUBMISSION SHALL CONSTITUTE ACCEPTANCE OF THE TERMS REFERENCED BELOW WITHOUT ADDITIONAL PROJECT AND /OR TENANT COSTS. ALL ABOVE CEILING EQUIPMENT /DEVICES THAT REQUIRE "ACCESSIBILITY" OR ARE IN DIRECT CONFLICT WITH THE ARCHITECTS' DESIRED DESIGN (ARCHITECTURAL CEILING DESIGN, LIGHTING PLACEMENT, ETC.) INTENT SHALL BE REMOVED AND RELOCATED. IF REMOVAL AND /OR RELOCATION IS NOT PHYSICALLY POSSIBLE OR DEEMED COST SENSITIVE, A LETTER SHALL BE SUBMITTED BY EACH TRADE TO THE ARCHITECT FOR REVIEW /APPROVAL PRIOR TO COMPLETION OF DESIGN -BUILD DOCUMENTS AND COMMENCEMENT OF CONSTRUCTION RELATED ACTIVITIES. © RELOCATED OR NEW 2X4 FLUORESCENT LIGHT TO MATCH EXISTING BUILDING STANDARDS. 07 RELOCATED OR NEW 2X2 FLUORESCENT LIGHT TO MATCH EXISTING BUILDING STANDARD. ® REPLACE ALL BENT /SRATCHED OR OTHERWISE DAMAGED CEILING GRID WITHIN SCOPE OF NEW CONSTRUCTION. REV ID R CODE ,Q i 'I LIANCE APPRO' D NOV 1 R 2012 City of Tuk` 'a1 I1 Di DID, g CITY OF TWA!. OCT 19 2012 PERMIT CENTER Symbols Legend RELOCATION. NOTE: IT IS THE INTENT THAT ALL ABOVE- CEILING SYSTEMS BE INVESTIGATED PRIOR TO BID SUBMISSION AND THAT SAID SUBMISSION TYPE SYMBOL MFG. DESCRIPTION SHALL CONSTITUTE ACCEPTANCE OF THE TERMS REFERENCED BELOW WITHOUT ADDITIONAL PROJECT AND /OR TENANT COSTS. ALL ABOVE- CEILING $ SWITCH EQUIPMENT/DEVICES OR ARE IN DIRECT / DEVICES THAT REQUIRE "ACCESSIBILITY" $ 3WAY SWITCH CONFLICT WITH THE ARCHITECTS' DESIRED DESIGN INTENT (ARCHITECTURAL CEILING DESIGN, LIGHTING PLACEMENT, ETC.) SHALL BE REMOVED AND iei BLDG STD EXIT LIGHT RELOCATED. IF REMOVAL AND /OR RELOCATION IS NOT PHYSICALLY POSSIBLE OR IS DEEMED COST- SENSITIVE, A LETTER SHALL BE SUBMITTED BY EACH EXHAUST FAN TRADE TO THE ARCHITECT FOR REVIEW APPROVAL PRIOR TO COMPLETION OF DESIGN -BUILD DOCUMENTS AND COMMENCEMENT OF BLDG STD GRID & TILE CONSTRUCTION - RELATED ACTIVITIES. 07 REPLACE ALL BENT /SRATCHED OR OTHERWISE DAMAGED CEILING GRID WITHIN SCOPE OF NEW CONSTRUCTION. 909 112th Avenue NE Suite 206 Bellevue, WA 98004 MoneyTree Floor 1 6720 Fort Dent Way Tukwila, WA 98188 DESIGN JPC DRAWN ccw CHECKED MP NO. 12 -0593 10 18 12 PFRMIT SUBMITTAL Demo Reflected Ceiling Plan & Reflected Ceiling Plan I -4.1 © 2012, JPC Architects, PLLC Author. CLAIRE WIESE Table: JPC STD.CTB Date/Time: 10/16/2012 10:55 AM Pen 0 0 N 8 EQUAL SPACES I' LAM (PL —X) VERTICAL SURFACES WITH (2) MELAMINE ADJUSTABLE SHELVES UNDER — COUNTER LIGHTING I 6 EQUAL SPACES Work Room Elevation LAM (PL —X) VERTICAL SURFACES WITH (1) MELAMINE ADJUSTABLE SHELF Scale: 1 /4 " =1' -0" Work Room Elevation LAM (PL —X) OUNTER TOP AND ACKSPLASH UPPORTS AS EQUIRED Scale: 1 /4 " =1' -0" 6 EQUAL SPACES /\ / P LAM (PL —X) VERTICAL SURFACES WITH (2) MELAMINE ADJUSTABLE SHELVES REFER TO ELEVATION io N 0 0 0 0 1 / / / / / i 1 :mod J 6 EQUAL SPA ES / / /. // i// / Work Room Elevation LAM (PL —X) OUNTER TOP AND ACKSPLASH UPPORTS AS EQUIRED Scale: 1 /4 " =1' -0" 6 EQUAL SPACES /\ / P LAM (PL —X) VERTICAL SURFACES WITH (2) MELAMINE ADJUSTABLE SHELVES 1 Work Room Elevation 0 N UNDER — COUNTER LIGHTING P LAM (PL —X) VERTICAL SURFACES WITH (1) MELAMINE ADJUSTABLE SHELF Scale: 1 /4 " =1' —O" 3" WIRE PULLS PLAM AT ALL EXTERIOR SURFACES TYPICAL 2' -0" U.N.O. r. N 4" RUBBER BASE AT TOE KICK REFER TO ELEVATION 0 0 0 0 0 0 0 Base Cabinet with Drawer PLAM COUNTER TOP AND BACKSPLASH PROVIDE BLOCKING BEHIND CABINET AND IN WALL AS REQUIRED MELAMINE AT ALL CABINET INTERIORS TYPICAL 3/4" ADJUSTABLE SHELF ON 2" O.C. SHELF CLIPS Scale: 1 " =1' -0" 15' —O 1 /4" 9 EQUAL SPACES a N ih 0 0 7 3 EQUAL SPACES 6' —O" Work Room Elevation Scale: 1/4 " =1' -0" PLAM FRAME 3/4" ADJUSTABLE SHELF ON 2" O.C. SHELF CLIPS HARDWARE PROVIDE BLOCKING BEHIND CABINET AND IN WALL AS REQUIRED UNDER CABINET LIGHT FIXTURE -SEE REFLECTED CEILING PLAN FOR LOCATIONS Upper Cabinet Scale: 1 " =1' -0" mozvAessmariaseer, ....:a REFER TO ELEVATION io N 0 0 0 0 • 0 0 0 0 0 0 0 `e€ 0 :mod 6 EQUAL SPA ES 1 Work Room Elevation 0 N UNDER — COUNTER LIGHTING P LAM (PL —X) VERTICAL SURFACES WITH (1) MELAMINE ADJUSTABLE SHELF Scale: 1 /4 " =1' —O" 3" WIRE PULLS PLAM AT ALL EXTERIOR SURFACES TYPICAL 2' -0" U.N.O. r. N 4" RUBBER BASE AT TOE KICK REFER TO ELEVATION 0 0 0 0 0 0 0 Base Cabinet with Drawer PLAM COUNTER TOP AND BACKSPLASH PROVIDE BLOCKING BEHIND CABINET AND IN WALL AS REQUIRED MELAMINE AT ALL CABINET INTERIORS TYPICAL 3/4" ADJUSTABLE SHELF ON 2" O.C. SHELF CLIPS Scale: 1 " =1' -0" 15' —O 1 /4" 9 EQUAL SPACES a N ih 0 0 7 3 EQUAL SPACES 6' —O" Work Room Elevation Scale: 1/4 " =1' -0" PLAM FRAME 3/4" ADJUSTABLE SHELF ON 2" O.C. SHELF CLIPS HARDWARE PROVIDE BLOCKING BEHIND CABINET AND IN WALL AS REQUIRED UNDER CABINET LIGHT FIXTURE -SEE REFLECTED CEILING PLAN FOR LOCATIONS Upper Cabinet Scale: 1 " =1' -0" mozvAessmariaseer, ....:a REFER TO ELEVATION io N 0 0 0 0 • 0 0 0 0 0 0 0 `e€ 0 :mod I O z0 rQ W W I' LAM (PL —X) VERTICAL SURFACES WITH (2) MELAMINE ADJUSTABLE SHELVES UNDER — COUNTER LIGHTING COPIER PROVIDED BY TENANT --P LAM (PL —X) VERTICAL SURFACES WITH (1) MELAMINE ADJUSTABLE SHELF 3" WIRE PULLS PLAM AT ALL EXTERIOR SURFACES TYPICAL 4" RUBBER BASE AT TOE KICK REFER TO ELEVATION '4- 2' -0" U.N.O. Base Cabinet PLAM COUNTER TOP AND BACKSPLASH PROVIDE BLOCKING BEHIND CABINET AND IN WALL AS REQUIRED MELAMINE AT ALL CABINET INTERIORS TYPICAL 3/4" ADJUSTABLE SHELF ON 2" O.C. SHELF CLIPS Scale: 1 " =1' -0" CODE COMPLIANCE APPROVED NOV 1 R 2012 City of Tukwila BUILDING DIVISRON IRECLlvw CITY OF TUKWII. A OCT 19 2012 PERMIT CENTER N U W I-- 2 U V a C] N CD 5 V7 Lit (I) C Q) 4—+ CT 0 MoneyTree Floor 1 6720 Fort Dent Way Tukwila, WA 98188 DESIGN DRAWN CHECKED NO. JPC CCW MP 12 -0593 10 18 12 PFRMIT SUBMITTAL Interior Elevations 1 -8.1 © 2012, JPC Architects, PLLC 0 w z 0 0 6 z 3 0 a 0 m m a - m X 0 0 0) 0 0 0 Author: CLAIRE WIESE Pen Table: JPC STD.CTB N 0 N 0 E_ 8 18 mils STUDS (25 GA) STUD SIZE STUD SPACING LIMITING WALL HEIGHT NON- COMPOSITE COMPOSITE 1625125 (1 -5/8 ") 12" 7' -7" 8' -10" 16" 6' -11" 8' -4" 24" 6' -0" 7' -11" 2505125 (2 -1/2 ") 12" 10'-6"" 11' -11" 16" 9' -6" 11' -3" 24" 7' -7" 10' -7" 362S125 3 -5/8" 12" 12' -9" 15' -4" 16" 12' -7" 14' -4" 24" 13' -1" 13' -5" 400S125 (4 ") 12" 18' -4" 16' -5" 16" 16' -8" 15' -4" 24" 14' -7" 14' -2" 6005 125 (6 ") 12" 25-5" 22' -1" 16" 23' -1" 19' -9" 24" 20' -2" 16' -9" 30 mils STUDS (20 GA - DRYWALL) STUD SIZE STUD SPACING LIMITING WALL HEIGHT NON - COMPOSITE COMPOSITE 162S125 (1 -5/8 ") 12" 9' -2" 9' -11" 16" 8' -4" 9, -2" 24" 7-3" 8' -3" 250S125 (2 -1/2 ") 12" 12' -9" 13' -2" 16" 11' -7" 12' -1" 24" 10' -1" 10' -9" 362S125 3 -5/8" 12" 16' -6" 17' -1" 16" 15-0" 15-8" 24" 13' -1" 14' -0" 400S125 (4 „) 12" 18' -4" 19' -0" 16” 16' -8" 17' -6" 24" 14' -7" 15-7" 600S125 (6 ") 12" 25-5" 25-6" 16" 23' -1" 23' -2" 24" 20' -2" 20' -3" 33 mils STUDS (20 GA) STUD SIZE STUD SPACING LIMITING WALL HEIGHT NON- COMPOSITE COMPOSITE -note 3 1625125 (1 -5/8 ") 12" 9' -6" 10' -4" 16" 8' -7" 9, -8" 24" 7' -6" 8' -9" 250S125 (2 -1/2 ") 12" 13' -2" 13' -11" 16" 11' -11" 12' -1O" 24" 10' -5" 11' -7" 3625125 3 -5/8" 12" 17' -1" 17'-10" 16" 15' -6" 16' -5" 24" 13' -6" 14' -9" 400S125 (4 ") 12" 18'-11" 19' -11" 16" 17' -3" 18' -4" 24" 15' -0" 16' -5" 600S125 (6 ") 12" 26' -3" 26' -9" 16" 23' -11" 24' -6" 24" 20' -10" 21' -7" NON - BEARING NON - STRUCTURAL LIMITING WALL HEIGHT TABLES 10. 9 GA. LATERAL SUPPORT WIRE WITHIN 3" )F EACH CORNER OF LIGHT FIXTURE. SPLAY NRES AS SHOWN AND FASTEN TO BEAM OR 3URLIN. MIN. OF 3 WIRE TURNS EACH. :ONNECTION POINT 10. 9 GA. LATERAL SUPPORT WIRE AT ENTER ENDS OF EA. FIXTURE. FIXTURE SUPPORT WIRE SUPPLIED BY CEILING :ONTRACTOR 60' MAX. TYP. 45' Light Fixture Bracing Diagram Scale: 3/4 " =1' -O" RECESSED FLUORESCENT FIXTURE CROSS TIE MAIN STRUCTURAL RUNNER 4' -0" O.C. NON- BEARING WALL HEIGHT TABLE NOTES 1. WALL HEIGHTS ARE BASED ON ALLOWABLE DEFLECTION OF L/24. 2. WALLS ARE TO RECEIVE MINIMUM 1/2" GWB BOTH SIDES. 3. IF WALL HEIGHT FOR COMPOSITE ACTION IS USED, GWB IS TO BE FASTENED WITH MINIMUM #6 SCREW AT 12" O.C. 4. HEIGHTS ARE BASED ON THE SSMA CATALOG. 5. TABLES ARE BASED ON 5 PSF LATERAL LOAD. 6. TABLES TO BE USED FOR NON- BEARING NON- STRUCTURAL STUD WALLS ONLY. 7. MATERIAL GAUGES ARE FOR REFERENCE ONLY. 8. WHERE GWB DOES NOT EXTEND TO TOP OF STUDS USE LIMITING WALL HEIGHTS FOR NON COMPOSITE WALLS AND PROVIDE MECHANICAL BRACING OF STUD FLANGES PER SSMA STANDARDS. 1 0 0 0 / STUD WIDTH TO MATCH WALL; 20 GA. TRACK CONNECTED TO CONC. SLAB W/ 3/16" DIA. X 5/8" LONG POWER ACTIVATED FASTENERS (4 MIN.) Partition Bracing Detail STRUCTURE ABOVE STUD WIDTH TO MATCH WALL; 20 GA. BRACE © 6' -0" O.C. MAX. 2 -1/2" X 20 GA. TRACK ANCHORED TO CHANNEL ACOUSTICAL TILE CEILING BLOCKING AS REQUIRED METAL CASING BEAD 22 GA. 2 -1/2" RUNNER & CONT. FOAM PAD - ATTACH TO CEILING GRID WI (2) #10 SCREWS CO 24" O.C. PAINT REVEAL FLAT BLACK OR USE BLACK RUNNER SEE PLANS FOR WALL TYPE Scale: 3 " =1' -0" (E) CONCRETE OVER METAL DECK CEILING CLIP WI (1)- 0.157 "0 HILTI X -J EMBEDDED 1 -1/2" INTO UPPER FLUTE (3) TURNS WITHIN 1 -1/2" OF END OF WIRE SEISMIC BRACE WIRE CEILING CLIP W/ (1)- 0.157 "0 HILTI X -J EMBEDDED 1 -1/2" INTO UPPER FLUTE COMPRESSION STRUT p) Ceiling Bracing Diagram Scale: 3/4 " =1' -0" (E) CONCRETE OVER METAL DECK (2) #8 SCREWS SHIM AS REQ'D, SECURE TO GRID INSULATION TO EXTEND 2' -O" BEYOND EACH SIDE OF WALL AS NOTED BELOW CEILING AS SPECIFIED PAINT REVEAL FLAT BLACK OR TAPED BLACK INSULATION AS NOTED BELOW ONE LAYER 5/8" GWB EACH SIDE OF WALL MTL. STUDS - WIDTH, GA. & SPACING AS NOTED BELOW CONT. MTL. RUNNER MECHANICALLY FASTENED TO SUB - FLOOR. SPACING AND EMBED DEPTH PER GOVERNING CODE & REGULATIONS SPECIFIED BASE FINISHED FLOOR 1/8" FOAM TAPE WALL TYPE WALL HT. STUD SIZE STUD THICKNESS STUD SPACING WALL THICKNESS INSULATION FIRE RATING/ UL DESIGN NO. COMMENTS WALL CEIUNG A 8' -6" " 2 1/2" / 18 Mils 24" O.C. 3 3 4" / SB SB - REF. 5&6/1 -9.1 FOR BRACING *SB =SOUND ATTENUATION BATTS Grid Ht. Partition Scale: 3 " =1' -0" APPROVED "FIRE EXTINGUISHER" SIGNAGE - 3" HIGH WHITE HELVETICA LETTERING ON RED BACKING OF 8 "X12" SIGN. PROVIDE SIGNAGE ON ALL FOUR SIDES OF COLUMN ENCLOSURE WHEN FIRE EXTINGUISHER OCCURS AT COLUMN BUILDING STANDARD FIRE EXTINGUISHER CABINET WHEN LOCATED AT COLUMNS, CABINET AND SIGNAGE TO BE CENTERED ON COLUMN ENCLOSURE. TYPICAL, U.N.O. HANDLE LL LL Q 0 oo SCHEDULED DOOR (OPEN OR CLOSED) WALL - MOUNTED TEL. OUTLET THERMOSTAT HARDWARE SET AS SCHEDULED ELEC. OUTLET TEL. OUTLET - 2 -3/4" VERIFY W/ HARDWARE SCHEDULE LIGHT S CH DOTTED LI INDICATES LO•'TION OF LARGER PLA FOR GANGED SWITCHES NOTE : INSTALL LOCAL ELECTRICAL AND TELEPHONE WALL OUTLETS AND SWITCHPLATES AT NEAREST STUD FROM SCALED LOCATION ON PLAN UNLESS SPECIFICALLY DIMENSIONED. Typical Mounting Heights Scale: N.T.S. NOTE: HEIGHTS ARE AS NOTED UNLESS DIRECTED BY B/S TO BE DIFFERENT 7 NOTES: 1. LATERAL BRACING CLUSTER: (4) 12 GA. GALV. SOFT- ANNEALED MILD STEEL WIRES SECURED TO MAIN RUNNER WITHIN 2" OF CROSS 'T' AND SPLAYED 90 DEGREES FROM EACH OTHER AT 45 DEGREES MAX. ABOVE HORIZONTAL. CLUSTERS PLACED 12' -0" O.C. MAX. AND 6' -0" MAX. FROM EACH WALL. WIRES SHOULD BE TAUT WITHOUT CAUSING CEILING TO LIFT. 2. SUSPENSION WIRE: 12 GA. GALV. SOFT- ANNEALED MILD STEEL WIRE ENCASED IN i" DIAM. CONDUIT (FOR UPLIFT RESTRAINT); SECURE WIRE TO MAIN RUNNER WITHIN 2" OF CROSS 'T'. CONDUIT TO OCCUR AT EVERY LATERAL BRACING CLUSTER AND SUSPENSION WIRES TO OCCUR AT 4' -0" O.C. MAX. EACH WAY. 3 TURNS MIN. WITHIN 3" TYP. NOTE #1 FASTEN RUNNERS TO PERIMETER WALL ANGLE AT (2) ADJACENT SIDES. PROVIDE MIN. 2" WIDE WALL ANGLE MAIN RUNNER, HEAVY DUTY CROSS 'T" 404 141.<1• /y\ `��� 2" MAX. TYP. jam 111141%11111 45' MAX. TYP. VIEW SHOWING LATERAL BRACING CLUSTER AND SUSPENSION WIRE NOTE #2 NOTE #1 RUNNER ENDS AT OPPOSITE WALLS TO FLOAT FREE ON PERIMETER ANGLE. PROVIDE 3/4" CLEARANCE BETWEEN ENDS OF GRID & WALL Seismic Wire /Compression Strut Connection Scale: 3/4 " =1' -0" #7 WALL TYPE WALL HT. STUD THICKNESS WALL THICKNESS EXISTING STRUCTURE FR GYPSUM COMPOUND OR FIRE CAULK "FIRETRAK" DEFLECTION TRACK INSULATION AS NOTED BELOW ONE LAYER 5/8" GWB EACH SIDE OF WALL INSULATION TO EXTEND 2' -0" BEYOND EACH SIDE OF WALL AS NOTED BELOW CEILING AS SPECIFIED CONT. MTL. RUNNER MECHANICALLY FASTENED TO SUBFLOOR. SPACING AND EMBED DEPTH PER GOVERNING CODE & REGULATIONS SPECIFIED BASE 1 /8" FOAM TAPE ACOUSTICAL SEALANT BOTH SIDES FINISHED FLOOR INSULATION WALL CEILING FIRE RATING/ UL DESIGN NO. COMMENTS 9' -0" 3 5/8" 30 Mils 24" O.C. 4 7/8" SB UL# U419 REFER TO DETAILS 8 &12 *SB =SOUND ATTENUATION BATTS FR=F1RE RESISTIVE 1 Hr. Rated Full Ht. Partition Scale: 3 " =1' -0" CO If) U \ VERIFY TYPE B NON -FULL HEIGHT WALL, UL #U419. ACOUSTICAL CEILING GRID ONLY 91-0" A.F.F. " SHAFT LINER 4 ", 20 Ga. GALVANIZED STEEL C -T STUDS CD 24" O.C. (1) LAYER TYPE 'X' GWB. PROVIDE U.L. OR I.C.B.O. APPROVED TENTING AT ALL RECESSED FIXTURES WITHIN TUNNEL CONSTRUCTION. * REFERENCE ICBO REPORT REPORT NO. 2541 3 5/8" MTL. STUDS W/ (1) LAYER 5/8" TYPE 'X' GWB EA. SIDE TO UNDER- SIDE OF TUNNEL. FINISH FLOOR 1 Hour Rated Tunnel Enclosure Scale: 1"=1'-0" 1 BRACE TO STRUCTURE ABOVE 4 ", 20 Ga. GALVANIZED STEEL C -T STUDS @ 24" O.C. 1" SHAFT LINER Tunnel Detail (1) LAYER TYPE "X" GWB Scale: 1"=1'-0" CODE COMPLiANCE APPROVED NOV 1 g 2012 City of Tukwila • ING DIVISION CITY OF TuKt "P1 OCT 19 2012 PERMIT CENTER 4 N H V w F- U V a 909 112th Avenue NE Suite 206 Bellevue, WA 98004 MoneyTree Floor 1 6720 Fort Dent Way Tukwila, WA 98188 DESIGN DRAWN CHECKED NO. JPC ccw MP 12 -0593 10 18 12 PERMIT SUBMITTAL Construction Details I -9.1 © 2012, JPC Architects, PLLC U) Zt- a 0 cm cm N 0 0 0 0 uP U) / 0 ▪ m / Q cc) rn o `m IX j X N 0 H- 0 Y Z Y o / a / F a• ° JPC STD.CTB Author CLAIRE 10/18/2012 9:29 AM E1o) 10 1 BASE, AS SPECIFIED Door Type A BLDG. STD. 3' -0" X B/S X 1 -3/4" SC, FLUSH PANEL WOOD DOOR FINISH: BLDG. STD. STAIN Scale: 3/8"=V-0" 1" " 1/2" Relite Sill Scale: 6"=V-0" 1/2" 1/4" TEMPERED SAFETY GLASS SET WITH GLAZING TAPE AT ENTIRE PERIMETER BUILDING STANDARD FRAME. ANCHOR TO STUD AT MIN. (3) LOCATIONS PER JAMB (CONCEAL FASTENERS) CARPET 1/2" N PARTITION AS SPECIFIED DOUBLE STUDS EACH SIDE AT JAMBS 1/2" (1) ADDITIONAL LAYER OF G.W.B. (WHERE OCCURS) co t, BUILDING STANDARD FRAME. ANCHOR TO STUD AT MIN. (3) N LOCATIONS PER JAMB (CONCEAL FASTENERS) 1• Door Jamb (Head Sim.) 1 -3/4" S.C. B/S WOOD DOOR Scale: 6 " =1' -0" 3 " -0° N • 1 I -10.1 10.1 BLDG. STD. 1 -3/4" SC, FLUSH PANEL WOOD DOOR FINISH: BLDG. STD. STAIN PROVIDE AND INSTALL RATED SIDELITE AND GLASS SYSTEM WITH FIRELITE PLUS BASE, AS SPECIFIED /2' 1 1/2" 1/2„ i k k Door /Relite Jamb 1/4" TEMPERED SAFETY GLASS SET WITH GLAZING TAPE AT ENTIRE PERIMETER BUILDING STANDARD FRAME. ANCHOR TO STUD AT MIN. (3) LOCATIONS PER JAMB (CONCEAL FASTENERS) 1 -3/4" S.C. B/S WOOD DOOR Scale: 6 " =1' -0" 2" 1" 1/2" r r M u Relite Jamb (Head Sim.) PARTITION AS SPECIFIED DOUBLE STUDS EACH SIDE AT JAMBS (1) ADDITIONAL LAYER OF G.W.B. (WHERE OCCURS) BUILDING STANDARD FRAME. ANCHOR TO STUD AT MIN. (3) LOCATIONS PER JAMB (CONCEAL FASTENERS) 1/4" TEMPERED SAFETY GLASS SET WITH GLAZING TAPE AT ENTIRE PERIMETER Scale: 6 " =1' -0" Hardware Set: HS -1 SINGLE NON —RATED DOOR WITH LATCHSET QTY 1 -1/2 PAIR — BUTT HINGES QTY 1 — LEVER LATCHSET QTY 1 — BLDG STD. DOOR STOP QTY 1 SET — SILENCERS Door Schedule: NO. TYPE FRAME HDWE RATING REMARKS REVISION 100 EXISTING RELOCATE EXISITING 20 MIN SITE VERIFY 101 B WD HS -1 102 A WD HS -1 RELOCATED 103 B WD HS -1 105 B WD HS -1 106 B WD HS -1 NEW 107 EXISITING EXISITING N U w F- U U 909 112th Avenue NE Suite 206 CD C7 Bellevue, WA 9 133 B WD HS -1 134 B WD HS -1 135 B WD HS -1 tP1(),- 31,-k 0 RE V 3EsA E DFOR q COD CO .� k ? i :"n \N ; ey C1C CS"b�.w 'M.J lar ����E L. t.. "k h.. APPROVED NOV 1 A 2012 City of Tukwil wi ILDING DIVISION RtGtIVto CITY OF TUKVAI. -' OCT 19 2012 PERMIT CENTER MoneyTree Floor 1 6720 Fort Dent Way Tukwila, WA 98188 DESIGN DRAWN CHECKED NO. JPC ccw MP 12 -0593 10 18 12 PFRMIT SUBMITTAL Door Schedule Elevations Details I -10.1 © 2012, JPC Architects, PLLC