HomeMy WebLinkAboutPermit D12-347 - EX PED LLC - TENANT IMPROVEMENTEX PED LLC 12600 INTERURBAN AV S D12-347 City ogukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 0004800003 Address: 12600 INTERURBAN AV S TUKW Suite No: Project Name: EX PED LLC Permit Number: D12-347 Issue Date: 12/11/2012 Permit Expires On: 06/09/2013 Owner: Name: GATEWAY OLYMPIA INC Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261 Contact Person: Name: DAVID KEHLE Address: 1916 BONAIR DR SW , SEATTLE WA 98116 Contractor: Name: PRECISION BUILDERS INC Address: PO BOX 98609 , DES MOINES WA 98198 -0609 Contractor License No: PRECIBI151C2 Lender: Name: SELF FUNDED - EX PED LLC Address: Phone: 206 - 433 -8997 Phone: 206 878 -2948 Expiration Date: 01/19/2014 DESCRIPTION OF WORK: NEW TENANT - REMOVE EXISTING NON - BEARING OFFICE PARTITIONS, INSTALL NEW NON - BEARING OFFICE PARTITIONS, INSTALL NEW FULL HEIGHT NON - BEARING WALL Value of Construction: $13,200.00 Fees Collected: $590.58 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0024 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -347 Printed: 12 -11 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Size (Inches): 0 N Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private:. Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N /7 Permit Center Authorized Signature f ,ti�/l�r -( /�/' _ % Date: w2 - ////� I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: /1 - / l Print Name: i k VS)--j-e 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. doc: IBC -7/10 D12-347 Printed: 12 -11 -2012 7: All construction shall be done in conform with the approved plans and the requirem of the International Building Code or International Residential International Mechanical Code, WashingtoWite Energy Code. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet m height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 19: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 21: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 23: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle doc: IBC -7/10 D12-347 Printed: 12 -11 -2012 is engaged from inside the tenant space. (IF hapter 10) 25: Door handles, pulls, latches, locks and o her operating devices on doors required to be cessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 26: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 29: Sprinlders shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 30: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 31: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2328) 32: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 33: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 34: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 35: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 36: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 37: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -347 Printed: 12 -11 -2012 ISITE LOCATION CITY OF TULA Community DeveloPirent Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building nit No. Project No. Date Application Accepted: Date Application Expires: For o ce use onl CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** }�, ,�' ,( King Co Assessor's Tax No.: ?4 Z Site Address: 12000 IU IGW es6a 4� G� Suite Number: Tenant Name: EX RP 1.-1 PROPERTY OWNER Name:% 006 Address:to _ Y 1Z lip re ' Z lo City: k X11 t State: » • Zip: CONTACT PERSON — person receiving all project communication Name: Vv. 10 riEttlk Address: la &3461a vU State: WO Zip/m I t, Phone:. +33 -tql Fax:/ �3(o_I�� Email:4 e Q agh i2QYG h . Co►44 GENERAL CONTRACTOR INFORMATION Company Name: - -jeo Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:Applications\Forms- Applications On Line12012 Applications2ermit Application Revised - 2.7- 12.docx Revised: Febniary 2012 bh New Tenant: Floor: 1 IfYes ' .. No ARCHITECT OF RECORD Company Name: Architect Name: go 0 r/Erwt Address: I1 I (o I b 16i12 State:Wb Zip:a 0 I IP Phone ,�. 33 Sef i. Fax .0' Tel Email: eIniehhte P afrfehlearGb. awl ENGINEER OF RECORD Company Name: U 1 4 Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 IsutLuh!Th PERMIT INFORMATI- 206 - 431 -3670 Valuation of Project (contractor's bid price): $ J ' WO • �/� Existing Building Valuation: $-1' M L1, b kI Describe the scope of work (please provide detailed information): Vetlare iucl op grrillosY2 140 .1, ►J Abu - ErIe D , KJ3rnu, Lay tuwN,ea-rt- 1394-eack4 emu, Will there be new rack storage? ❑ ....Yes o If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 11 _ -Il7Ai(ifP7 Compact: Handicap: Will there be a change in use? ❑ Yes 44- No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers gl Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes A. No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1ApplicationsWorms- Applications On Line\2012 Applications\Permit Application Revised - 2.7.12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lst Floor / /D t-1' 4> Y.- / f 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 11 _ -Il7Ai(ifP7 Compact: Handicap: Will there be a change in use? ❑ Yes 44- No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers gl Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes A. No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1ApplicationsWorms- Applications On Line\2012 Applications\Permit Application Revised - 2.7.12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES - • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE Signature: Print Name: 04;k1IIIZED AGENT: Mailing Address: rVP I(E H: Applications'Forms- Applications On Line12012 Applications'Permit Application Revised - 2.7- I2.docx Revised: February 2012 bh Date: ID`ZS Day Telephone: I bIIIr City State Zip Page 4 of 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.Tukwila WA .gov RECEIPT Parcel No.: 0004800003 Permit Number: D12 -347 Address: 12600 INTERURBAN AV S TUICW Status: ISSUED Suite No: Applied Date: 10/26/2012 Applicant: EX PED LLC Issue Date: 12/11/2012 Receipt No.: R12 -03387 Payment Amount: $63.00 Initials: TLS Payment Date: 12/27/2012 01:20 PM User ID: 1670 Balance: $0.00 Payee: PRECISION BUILDERS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 6092 63.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 63.00 Total: $63.00 doc: Receiot -06 Printed: 12 -27 -2012 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0004800003 Address: 12600 INTERURBAN AV S TUKW Suite No: Applicant: EX PED LLC RECEIPT Permit Number: D12 -347 Status: APPROVED Applied Date: 10/26/2012 Issue Date: Receipt No.: R12 -03298 Payment Amount: $359.70 Initials: LAW Payment Date: 12/11/2012 12:02 PM User ID: 1632 Balance: $0.00 Payee: PRECISION BUILDERS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 6057 359.70 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000.322.100 355.20 STATE BUILDING SURCHARGE 640.237.114 Total: $359.70 4.50 rinr. RAt int_f1R Printarl• 19_11 -7f112 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0004800003 Permit Number: D12-347 Address: 12600 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 10/26/2012 Applicant: EX PED Issue Date: Receipt No.: R12 -02977 Payment Amount: $230.88 Initials: WER Payment Date: 10/26/2012 10:23 AM User ID: 1655 Balance: $359.70 Payee: DAVID KEHLE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 025233 ACCOUNT ITEM LIST: Description 230.88 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 230.88 Total: $230.88 rinr.• RPt int -nR Printari • 1(1 -7R -7(117 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO.- -.- CITY OF TUKWILA BUILDING D_ 'IVISION: 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: eV.. i•t• Li..0 Type of Inspection: Y i NAL Address: 0.-60 0 ....-C.13-1 F iZ,AA,J AO Date Called: Special Instructions: Date Wanted:. ; y ,ate 'p`.m:. Requester: Phone No: 1 O(,- 3S `.,,— i. QApproved per applicable codes. COMMENTS: Corrections required prior to approval:.. I-) 71C,..iSQ4 rt Q,��ti�lc� - nn IAA' J If 'spec ybr. Date: 1--I n REIN�PECTION FEE REQUIRJD. Prior to aid, t 6300 Southcenter Blvd.. Suite 100. 1 next inspection fee: mustbe--; Call to schedule reinspection: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT:NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 =(206) 431=3670 Permit Inspection Request Line (206) 431 -2451 Project: :C x .1. 1..L.e. Type of Inspection: rcAiv\it c =... , Addresss�: ‘3..006 - 1JiE Q.1Acz.. $h1/43 v\-k.: Date Called: S -'' Special Instructions: Date Wanted: i • -i t t ,t=] i12 .l vi i p.m. Requester: Phone No: - : Approved per applicable codes. COMMENTS: ElCorrections required prior to. approval:- C.-6 ULF Inspeet Date:\ I I REINSPECTION FEE REQUIRED. Prior to next inspection fee must, be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule:reinspection INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444-Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: T xee of Inspection: Address: jabdo J. .65 Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable codes. COMMENTS: Corrections required prior to approval. t '( -0 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: dvv -� s--? Date: //7//., Z Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: City: • Word /Inspection Record Form.Doc Company Name: State: 6/11/10 Zip: T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 11)/01- f.5q7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila Wa. 98188 206-575-4407 Project: - : Type of Inspection: Sri Address: 1 g_600 Suite #: j4- S , ' Contact Person: Special Instructions: .-3 se _ oc Phone No.: . Approved perapplicable codes. Corrections required prior to approval. COMMENTS: - .. - Sprinklers: Fire Alarm: „- i Hood & Duct: _ _ Monitor: , ------ se _ oc Pre-Fire: ,,.- Permits: ,, rix - 0.(- ..... . OCJ5 2)- e--3,j 11%,i TO z.- I . Needs Shift Inspection: Date: .. - Sprinklers: Fire Alarm: „- i Hood & Duct: _ _ Monitor: , ------ ..:- Pre-Fire: ,,.- Permits: ,, Occupancy Type: Inspector: A.,.. Date: / /3/ (3 Hrs.: i $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila FinanCe Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 PR A S kehle Architect November 19, 2012 City of Tukwila Dept. of Public Works 6300 Southcenter Blvd. Suite 100 Tukwila, Washington 98188 Attn: Plan Review Re: ExPed 12600 Interurban Avenue South D12-347 Dear Staff, The tenant has made several revisions to the project and I have clouded and marked the revisions on Sheet T -2 with revision of 11- 19 -12. They have removed an additional office and restored an office, made a training room and new office, removed a wall to create a larger lunch room, added a door between the warehouses, added a clearstory window in an office wall, and added safety glazing in the overhead doors. All changes are clouded and flagged with rev 1. If you have any questions please call. Sinc David Ke le DK/dk Cc: Mr. Gregory Coleman 0225 /tucexped /11 -19 -12 1916 Bonair Drive S.W. Seattle, WA 98116 REVISION N0;1 RECEIVED CITY OF TUKWILA DEC 1 1 2012 PERMIT CENTER (206) 433 -8997 fax (206) 246 -8369 email: dkehle @dkehlearch.com PERMIT `' f= .`D COPY. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -347 DATE: 12 -11 -12 PROJECT NAME: EX PED LLC SITE ADDRESS: 12600 INTERURBAN AV S Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS: Building Division MI Public Works ❑ AW\ Fire Prevention I Structural Planning Division ❑ Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete I I Complete DUE DATE: 12 -13 -12 Not Applicable Comments: Permit Center Use'Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01 -10 -13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 �° ° �r PE C PLAN REVIE • 98NG SLIP ACTIVITY NUMBER: D12 -347 PROJECT NAME: EX PED LLC DATE: 10 -26 -12 SITE ADDRESS: 12600 INTERURBAN AV S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued EPARTMENTS: Bu Public Works i-Ulc ire Prevention Structural f*\ Okk '11/ Planning Division pi Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete El DUE DATE: 10 -30 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ LETTER OF COMPLETENESS MAILED: Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Nr Structural Review Required REVIEWER'S INITIALS: No further Review Required n DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 11 -27 -12 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PROJECT NAME: xpp(1 SITE ADDRESS: ) )-r000 -14e&e vvi S PERMIT NO: • 'D I 324 7 ORIGINAL ISSUE DATE: IX% 1 1— REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 l.)-- l I- ►� Vi' t --7 -1k 11-S Summary of Revision: c Q, 'L.- ,,-. 4-c/ n.S to i f Received by: O.K. REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 101,11117,/' ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # O' Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector =or Plans Examiner Plan Check/Permit Number: Q ' Project Name: Project Address: IZct I1iizgukE 0, Contact Person: 2' 12 Wig Phone Number: 2 %2- X73• c 141+" Summary of Revision: lI ision: RECEIVED MTV OF TUKWILA IDEC 1 120121 PERMIT CENTER Sheet Number(s): 1,1 1'7i "Cloud" or highlight all areas of revision including date of revhsion Received at the City of Tukwila Permit Center by: -- Entered in Permits Plus on \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople Peer Friendly Page 0 General /Specialty Contractor A business registered as a construction contractor with Lftl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name PRECISION BUILDERS INC UBI No. 600553713 Phone 2068782948 Status Active Address Po Box 98609 License No. PRECIBI151C2 Suite /Apt. License Type Construction Contractor City Des Moines Effective Date 2/22/1985 State WA Expiration Date 1/19/2014 Zip 981980609 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WESTCBI133M3 WEST COAST BUILDERS INC Construction Contractor General Unused 7/23/1987 6/1/1989 Archived PRECIB'163BR PRECISION BUILDERS Construction Contractor General Unused 1/19/1984 1/19/1986 Archived Business Owner Information Name Role Effective Date Expiration Date SANBURN, SCOT DEAN President 02/22/1985 Amount SANBORN, ELIZABETH ANNE Secretary 12/16/2011 BKW1353747076 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 DEVELOPERS INS CO 415171C 01/19/2002 Until Cancelled $12,000.00 01/14/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 20 Ohio Cas Ins Co BKW1353747076 07/15/2012 07/15/2013 $1,000,000.00 07 /10/2012 19 Ohio Cas Ins Co BKW1253747076 07/15/2011 07/15/2012 $1,000,000.00 07/07/2011 18 0010 CABINS BL01053747076 07/15/2010 07/15/2011 $1,000,000.00 07 /13/2010 17 0010 CABINS 8L01053747076 07/15/2009 07/15/2010 $1,000,000.00 06/23/2009 16 0010 CABINS BL053747076 07/15/2008 07/15/2009 $1,000,000.00 07/11/2008 15 0010 CABINS 53646587 07/15/2007 07/15/2008 $1,000,000.00 07/17/2007 14 PROBUILDERS SPECIALTY INSURANC LAM5005190 07/15/2006 07/15/2007 $1,000,000.00 07/14/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 12/11/2012 150' -0" 150-0" 150' -0" 50-0" 50I-0" =.._,._I\-- `i 111101111.111 11101•1111111 SUITE 'A' TENANT AREA qF WORK 12600 TENANT SUITE 'A' (4,500 S.F.) MINNS - - - I. ID REMOVE EX. WALL EX. CFFICE EX. EX - ' OFFICE ADJACENT TENANT NO WORK 1- CONSTRUCT NEW WALLS AND DOORS EX WA 50' -0" r REMOVE EXISTING WALLS SEE DEMO PLAN P. BD. CEILING EX. GYP. BD. CEILING j -►r 11 sirs= .w -x-1,1 1. 11 — 111 RELOCATE 6 EXISTING LIGHTS REMOVE EXISTING WALLS SEE DEMO PLAN 11 ADJUST LIGHT SWITCHNG TO NEW AREAS. ADJUST NVAC FOR NEW AREAS REFLECTED CEILING PLAN: OFFICE DEMO SCALE: 118 "•1' -0" BUILDING 'A' (13,44 S.F.) OVERALL FLOOR PLAN SCALE: 1/I6 114-0" 0 0'I' FILE COPY !Bradt No..)11• 34,7 per r view approval is subject to orrors and omissions. c construction documlerds does not aut =za 111: :..;:aticn of any adopted code or oitinancs. Receipt of pproved Field ., ' and S' City Of TtJkwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of T uI. �rila Building Division. f jC T Z: r 9v ;: ion3 will r& ui a new plan submittal a ;:+ m y i n,-;lude additional plan review fees. 16' 32' 64' SCALE 1116" • 1' -0" SEPARATE PERMIT REQUIRED FOR OrMichordcal !Mark* City of Tukwila ,BUILDING DIVISION EXISTING CEILING GRID AND TILESJ4O CHANGES EX. GYP. SD. CEILING D O PHONE (206) 433 -8997 SYM DATE DESCRIPTION PROJECT FAX 206) 246 -8369 0225 10 -25 -12 SUBMIT FOR PERMIT DRAWN BYt I' 1 + 1 11-1941 REY SY TENANT DK .R `1 DATE 10 -23 -12 �� .I CHECKED BY 0 ID E. 1EHLE 1916 BONAIR DR S DAVID STATE 0FWASNINMN SEATTLE, WASHINGTO DATE 9 8 1 1 6 - • ' REVIEWED FOR 11 APPROVED E COMPLIANCE ea 1 maw—. i I!... !II iiiir�lSl."'"�,-. IMME ,I�I�I'EI 11•1 1 11 Mi.,_ Il_ ir�l1 ►1 1 II ■ I 11: :- II II II Fr PAINEL4111. DEC 2 a 2012 DEC 2 R 2012 A-- City of Tukwila LDING DIVISION EX. GYP, BD. CEILING RELOCATE EX LIGHT SWITCH RELOCATE b EX LIGHTS REVISION N0: I ADJUST LIGHT SWITCHING TO NEW AREAS. ADJUST I4VAC FOR NEW AREAS AIN) wa PP' C :\Documents and Settinga\AII Users\Documents\CAD\2002 \0225 RRE Tenant Improvements \Tukwila Commerce Park\BLDG A\EXPED LLC 1260010- 23- 12\T -1 11- 19- 12.dwg, T -1 (2), 1 RECEIVED LIT" OF TLIKWILA DEC 1 1 2012 ?E MIT CENTER REFLECTED CEILING PLAN: OFFICE NEUJ SCALE: 118 0.1' -0" Lti 0 Arn • • / 40 4 • z Q cn �IH H H a <*1 wz At ar4 Z I-4 1-4 121 :4 50' -0" i EMO NOTS: 1. REMOVE EXISTING WALLS, DOORS AND FLOORING THROUGHOUT AS SHOU.N. PATCH AND REPAIR FLOORS, WALLS AND CEILINGS 2. ANY ELECTRICAL OR PLUMBING NOT BEING REUSED TO BE CAPPED AND NOTED ON AN 45-BUILT. ELECTRICAL TO BE PULLED TO A J -BOX AND LA6ELED WITH PANEL NUMBER AND CIRCUIT. 3. MODIFY HVAG AS REQUIRED FOR NEW CANDITIONS 4. MODIFY SPRINKLERS AS REQUIRED FOR NEW CONDITIONS. a FLOOR FLAN: DEMO SCALE: 1/8 "2I' -0" 50' -0" EX. CABINET TO REMAIN- WINDOW SCHEDULE A. RELOCATE EXISTING MTL FRAME, INSTALL NEW SAFETY GLAZING IN WINDOW. VERIFY SIZE (4)4') 5. REMOVE PORTIONS OF WALL FOR NEW CLERESTROY WINDOW, 8'X1' -6 ", IN MTL FRAME TO MATCH EXISTING. ROOM SCHEDULE (c) a EX. OPEN OFFICE NEW OPEN OFFICE COMMON PATH OF NAVE : ' THAN 100 LF 14' 1 1 NEW TRAINING fd•t. 224 SF a V20.II OCC. SINGLE EXIT V. ADA SHOWER NEW WAREHOUSE 965 OF . 11500-2 OCC. elt4LE EXIT REPLACE EXISTING FINISHES WITH NEW FINISHES. VERIFY WITH LANDLO 'r AN T N NEW LUNCH ROOM, REMOVE EX. FLOORING AND ADD NEW LAMINATE FLOORING AND NEW SASE. POOR SCHEDULE: EXISTLNG El EX. 3'X1' AULUMINUM STOREFRONT WITH INSULATED GLAZING AND PADDLE EXIT E2,3, EX. 31X1' SC WOOD DOOOR, MTL FRAME, E5 PRIVACY LOCK E4 EX. 3'X1' SC WOOD DOOR, MTL FRAME, LOGKSET E6 EX. 3'X1' k MTL DOOR, MTL FRAME, LOGKSET, (INSIDE HANDLE TURNS FREELY FOR EXIT) E1,E8 XI TING OVERHEAD DOOR REMOVE TOP TWO PANELS AND REPLACE WITH GLAZING (CLEAR N TP PANEL, OBSCURE IN SECOND PANEL, SAFETY GLAZINGFOR BOTH) OFFICE NEW WAREHOUSE 966SF.V500 ■2000 SINGLE EXIT UNDER 100' TRAVEL KTANCE 24' -1 I/2" REPLACE TOP TWO PARIS WIN SAFETY GLAZING, TOP PANEL 70 ISE CLEAR GLAZ SECOND PANEL WITN OBSCURE GLAZNG. FLOOR FLAN: NEW SCALE: 1/8".11-011 LUAU. TYFE SC-4EUL: A. NEW FULL HEIGHT WALL FROM FLOOR TO ROOF DECK PROVIDE DEFLECTION HEAD TRACK AT ROOF SEE DETAIL. 6"X20GA • 24° O.C. WITH 5/8" G7P BD EACH SIDE. 8. NEW IN FILL WALL TO MA7G1-1 EXISTING WALL GONSTRUGTION. 3 5/8" X 15 GA STEEL STUD AT 24" OG. WITH 5/8" GYP BD C. NEW 3 5/8" 25 GA. STEEL STUD AT 24" Q.G. WITH 5/8" GYP BD EACH SIDE TO EX. SUSP. CEILING, SOUND INSULATE. W/ G NER4L NOTES: 1. THERE ARE NO CHANGES TO THE BUILDING ENVELOPE 2. THERE ARE NQ CHANGES TO THE EX5TING EXITING 3. CHANGES N LIGHTING WILL BE THE SAME WATTAGE RELOCATED OR NEW 4. NO EXTERIOR CHANGES RECEIVED CITY OF TUKWILA DEC 1 1 2012 PERMIT CENTER POOR SC14EULE: NEUJ MATCH EXISTING, 1,2 NEW DOOM � 70 H�A S.C. WOOD HANDLES EXISTING), MTL FRaME, LOGKSET (INSIDE REVISION NO. I HANDLE TURNS FREELY FOR EXIT NEW 42 "X1' -0" SC WOOD DOOR WITH MTL FRAME, LATCI.ISET, WALL STOP, WEATHERSTRIP. 4. NEW PAIR OF 3'- 0 "X1' -0" SC WOOD DOORS, MTL FRAME, LATCHSET, CLOSER WIN COORDINATOR, WALL STOP, SILENCERS. _../\,,,.C:1DQcuments and Se ( d -3 1-17 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 a 2012 BUILDING DIVISION ON 1 N 00 M I ss V�.I ... .0 ci.....z, con Qa Z3.- O W u m W °a MI I • 1 11E0 i ings\A Documents\CAD12002\0225 RREEF\ Tenant Improvements\Tukwila Commerce Park1BLDG A\EXPED LLC 1280010- 23- 121T -1 11- 19- 12.dwg, T-Ir1 1 ' 1 2 :13: Millik TRUE NORTH TENANT SPACE UNDER THIS PERMIT • 1"r • PROJECT SITE NOltifi NORT1,4 VICINITY MAP ICA FR.91)EPT, AN• puLpitio CODE : 2009 IOC WITH WASHINTON STATE AMENPMENT8 LOCATIQN: PARCEL. NUMBER: ACCOUNT NUMER ; PON$TROCTION TYPE: OCCUPANCY GROOP(6): ZONE: LOT AREA: TENAT etre AREA; OFFICE: WAREHOUSE: TOTAL: PAI: REVISIONS No changes shall be made to the scope cf work without prior approval of Tukwila Building Division. t7 :: r o , t i c n o rz..'quiro a nal? pn submittl End may ind:ude additional plan review fees. TUKWILA CatIERCE F'ARic PUILDItia A 12600 INTERN AVE. TUKWILA, WA p0�4000003 0040000Mo V.1) SPRINKLERED GU P B omcg, 51 WAREHOUSE C Lol 40,2% 60 Fr (wee 44Res) 2�S$ 2,462 SF. 4,T10 etP. NO CHANGE SEPARATE PERMIT REQUIRED FOR linteichardcal GPEtectrical GPPlumbing Chefs POMO City of Tukwila BUiLDING DIVISION REMOVE EX5TI NG NCN-SEARII•0 OFFICE PARTITIONS, INST44 NEW NoN.15EARiNci oFFIcE FtARTITIONS AN P P414, WEIGHT DEMI% WALL NO C4444(48 TO SUILDIlio ENVELOPE LIGHTING WILL REUSE ExISTIt4 WITH ANY NEW Flximes WITi4 SAME WATTAGE LE*441. popfzipTioi LEWIS C Cup aEo N SI•44,15 E 1439.11 FT FROM NUB AT ENP OP CURVE ON cENT LN OF PUWAMIS14-RENTON JUNCTION RD 52 HUP BEING APPRox 1200 FT N AND 440 FT W OF 1/4 CCM BET SEC$ 14 4 1E03-4 TH N 45,24000 W 2538 FT T14 N 0$-A10-00 E 52 FT TO TRUE BEG TH 02-40-30 E 580 FT T N 58-22,30 E 64335 FT T14 tsi 01-8140 W ,343 FT TO LEFT BANK OF DOWAMI844 RIVER BEING DOUNDIRT OF LEWIS C TI4 eittix ALG ep PAN< OF RIVER TO PT N po.3$.40 W OF 'ME BEG. S 00-3t-40 E TO NE SEO ALSO FOR OF D it) OF ADOVE ESCROW LAND S.Y 16.18 Ft 00.0 4 lb FT STRIP ADJ Atto PARL TO oP ELY LN OF R/W oF p 8 Et.gc co FOR JOINT RD ;LOT 41 OF PLAT give,Reipe INTERURBAN R5 FILE COPY Permit o. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 07 2012 4;- City of Tukwila BUILDING DIVISION rm.ow approval 13 subject to errors and omissions. of constracttn doomerds does not authviza E ..).,...11jon ry adopted code or ordinance. Rece:pt s acknowiadged: By Date:,. 1' - Oty Of nikwila BUILDING DIVISION b1,7,-- 3'17 RECEIVED CITY OF TUKWI OCT 2 6 2012 -3 N =oddments and Settings1All Userskliodumente1CAD■2002‘0225 RREER Tenant ImPnavernenterukwile Commerce Park\BLDG AlEXPED LLC 12600 10,23-12VT-0.dW e 50' -0" SUITE 'A' TENANT AREA qF WORK 12600 TENANT SUITE 'A' (4,500 S.F.) 1•1111101110 11111•11111111 50' -0" 50' -0" 50' -0" 50' -0" EX. OFFICE Ex COPY AREA EX. LUNCH ADJACENT TENANT NO U Q ( EX. WAF4HOUSE 50' -0" EX. GYF ADJUST LIGHT SWITCHING TO NEW AREAS, ADJUST RVAC FOR NEW AREAS REFLECTED CEILING 'LAN: OFFICE DEMO SCALE: 1/8 "•11- 0" EXISTING WALLS 0 PLAN EXISTING WALLS 0 Pt.AN !WILDING 'A' (13,441 5 .P.) OVERALL FLOOR PLAN SCALE: 1/i6" • 1' -0" EXISTING CEIL AND TILESNO EX. GYP. O. EX. GYP. SD. 0'I' 8' 16' 32' 48' 64' SCALE 1/16" s 1' -0° 1 �•� r - --, = j 11 REMOVE it 11 41 SEE DS r' NG GRID NAMES P. ea CEILING - ► r = — _ r _ 11 , SEE DS _ ,__� U U � 1 j 11 I I1 I II 11 11 L-- �u / II =1J I I ....... II 11 , 11 , ' 11 11 >7 . 11 it • 1 IIIIIMIlaw ''. > 1 1 hj - it — ,. i3D. CEILING — RELOCATE EXISTING LIG EX. GYF ADJUST LIGHT SWITCHING TO NEW AREAS, ADJUST RVAC FOR NEW AREAS REFLECTED CEILING 'LAN: OFFICE DEMO SCALE: 1/8 "•11- 0" EXISTING WALLS 0 PLAN EXISTING WALLS 0 Pt.AN !WILDING 'A' (13,441 5 .P.) OVERALL FLOOR PLAN SCALE: 1/i6" • 1' -0" EXISTING CEIL AND TILESNO EX. GYP. O. EX. GYP. SD. 0'I' 8' 16' 32' 48' 64' SCALE 1/16" s 1' -0° CEILING RELOCATED LICIT MATCHING WATTAGE. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 7 2012 --- City of Tukwila ___ -L. BUILDING DIVISION PcCEIVED rwry nr -r; i�n1 ADJUST LIGHT SWITCHING TO NEW AREAS. ADJUST NVAC FOR NEW AREAS K Iil\ C:1Documents and Sett1ngslAll Users \Documents\CAD120021• ;-5 RREEF\ Tenant ImprovementslTukwila Commerce Perk\BLDG A\EXPED LLC 1260010- 23- 121T- 1.dwg, T -1 OCT 2 6 2012 PERMIT CEhlTE=: REFLECTED CEILING PLAN: OFFICE NEUJ SCALE: 1 /8 "sI' -0" w O DRAWN BY DESCRIPTION 1 12 3:46:32 M �•� r - --, = = NG GRID NAMES 1 1 I II 11 , 11 , ' >7 . IIIIIMIlaw ''. > ...* 0. ''.."" '..'..ta---"" V VT.".....: IOW ADJUST LIGHT SWITCHING TO NEW AREAS. ADJUST NVAC FOR NEW AREAS K Iil\ C:1Documents and Sett1ngslAll Users \Documents\CAD120021• ;-5 RREEF\ Tenant ImprovementslTukwila Commerce Perk\BLDG A\EXPED LLC 1260010- 23- 121T- 1.dwg, T -1 OCT 2 6 2012 PERMIT CEhlTE=: REFLECTED CEILING PLAN: OFFICE NEUJ SCALE: 1 /8 "sI' -0" w O DRAWN BY DESCRIPTION 1 12 3:46:32 M 501 -0n INV EX. OPEN OFFICE REMOVE EXISTING WALL AND DOORS, EX. OFFICE EX ADA SHOUER N PMO NOTES: n 11 111 EX OFFICE `11 n EX OFFICE II 11 11 1 II /s 11 W EX OFFICE EX OFFICE REMOVE EXISTING WALLS AND DOORS. EX WAREHOUSE FLOOR PLAN: DEMO SCALE: I/8" a I' -0" 1. REMOVE EXISTING WALLS, DOORS AND FLOORING THROUGHOUT AS SHOWN. PATCH AND REPAIR FLOORS, WALLS AND CEILINGS 2. ANY ELECTRICAL OR PLUMBING NOT BEING REUSED TO BE CAPPED AND NOTED ON AN AS- BUILT. ELECTRICAL TO SE PULLED TO A J -BOX AND LABELED WITH PANEL NUMBER AND CIRCUIT. 3. MODIFY HVAC AS REQUIRED FOR NEUJ CONDITIONS 4. MODIFY SPRINKLERS AS REQUIRED FOR NEW CONDITIONS. 50-0" EX OPEN OFFICE w ICJ EX ADA RR RR E2 :qX. ADA �; ----RR NEW OPEN OFFICE CCM'1 % PATH OF TRAVEL LESS THAN 100 LF ROOM SCHEDULE REPLACE EXISTING FINISHES WIN NEW FINISHES. VERIFY WITH LANDLORD AND TENANT DOOR SCHEDULE: EXISTING El EX. 3'X1' AULUMINUM STOREFRONT WITH INSULATED GLAZING AND PADDLE EXIT E2,3, EX. 3'X1' SC WOOD DQOOR, MTL FRAME, E5 PRIVACY LOCK E4 EX. 3'X1' SC WOOD DOOR, MTL FRAME, LOCKSET E6 EX. 351' H. MTL DOOR, MTL FRAME, LOCKSET, (INSIDE HANDLE TURNS FREELY FOR EXIT) E1,ES EXISTING OVERHEAD DOOR poo SC1-UjE: NEW MATCH EXISTING, NEW DOORS TO HAVE DYER HANDLES 1,2 NEUJ 3'X1' S.C. WOOD (MATCH EXISTING), MTL FRAME, LOCKSET (INSIDE HANDLE TtNRtslS FREELY FOR EXIT WALL STOP; CLOSER WEATHERSTRIP NEW OFFICE NEB WAREHOUSE 166 • /5�'2 OCC SMGL EXIT UNDER 100' TRAVEL DIV 24' -11/2" FLOOR PLAN: NEW SCALE: 1/8 "01'-0" VJJALL TYFE SCHEDULE: A. NEW FULL HEIGHT WALT. FROM FLOOR TO ROOF PECK PROVIDE DEFLECTION HEAD TRACK AT ROOF SEE DETAIL. 6 "X10GA 0 14" O,C. WIN 5/8" GYP SD EACH SIDE. B. NEW IN PILL WALL TO MATCH EXISTING WAI.I. CONSTRUG710N, 3 5/8" X 25 G4 STEEL STUD AT 24" O.C. WITH 5/8" GYP BD EACH SIDE. GNIEF411.. NOTES: 1. THERE ARE NO CHANGES TO THE BUILDING ENVELOPE 2. THERE ARE NO CHANGES TO THE EXSITING EXITING 3. CHANGES IN LIGHTING WILL BE THE SAME WATTAGE RELOCATED OR NEW 4. NO EXTERIOR CHANGES REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 7 2012 City of Tukwila BUILDING DIVISION RECEIVED OCT 2 6 2012 PERMIT CENT DRAWN BY a DESCRIPTION 03,.• con '^^ Q 3 s s Z w mW CA W ch MINSINNIImiposmonnem C:\Documents and Set ings\All UserslDocuments \CA012002\O225 RREEFI Tenant Improvements\Tukwiia Commerce ParIABLDG A\EXPED LI,.0 12600 10-23-12\T-1.dwg, - , 1 3:46;53 L DRAILERS COUNT ELEV4TION "'"`""""" SCALE: 3/8' t 114:1 NOTES: CABINETRY TO BE FLUSH OVERLAY, PLASTIC LAMINATE INSIDE TO HAVE KORTRON FINISH HARDWARE TO BE CONCEALED HINGES, EUROPEAN,26D WIRE PULLS TO BE 26D FINISH DRAWER GUIDES TO EE METAL, SELF CLOSING ADJUSTABLE SHELVING OUTLETS TO BE 444" TO CENTER (MI5$ BACKSPLASH) ROOF STRUCTURE GLB1PURLM OR STIFFENER + I/2" SPACE GYP.BD. TO GYP. 8D. EA. SIDE \74>: ALT.1 -1EAD DETAIL. SCALE: I.1/2" , 1' -0" MINIM OMNI 6" DEEP LEG CRACK ATTACH TO GL.B. W/3 1 5/8" SCREWS • 2' -0' OTC. (DEEP LEG IS 3 ") STUDS 20 GA • 2' -0" C.C. NOT ATTACHED TO TRACK BUT LAPPED up INSIDE 1 ". GYP.BD. ATTACHED TO STUD -NOT TO STRUCTURE OR TRACK SECTION FOR WALLS GREATER THAN S'- 0" IN WIDTH WITHOUT AN INTERSECTING WALL, PROVIDE 12Sa. WIRES SPLAYED • 45 t0 AN EYE SCREW • ROCF ANp Top OF WAL '■ ■■■■■■■■■■■■■■1111111r,■■ ■■■■■■■■■► ATTACH TOP RUNNER TRACK TO CEILING GRID WITH 2 - Ya x 1 IV LONG SCREWS AT 2' -0" O.C. TYPICAL STUDS - 3 5/8", 25G,A. STEEL • 24" O.C. (FOR WALL INSULATION SEE MAW '5 /S" GYP. BD. EA SIDE (FLUSH FINISH). sEg REFLECTED CEILING PLAN Imp TYPICAL WALL HEAD TO $USPENDWD CEILING SCALE; 1- v2. "I' TYPICAL. WALL FRAMING ATTACH BOTTOM TRACK TO CONC. FLOOR W/ POWDER DRIVEN ANCHORS, HILTI OR APPROVED I" EMBEDMENT AT 24" Q.C. 2 1/2" RUBBER BASE • CARPET 4 4 4 IU4LL TQ SAAB SCALE: . 11-0" WOOD DOOR HOLLOW METAL DRY WALL FRAME (MATCH EXISTING) 54" G. 8D. BOTH SIDES STEEL STUDS 5/8" GYP. BD. (TYPE 'X' 0 FIRE RATED WALLS.) ACOUSTICAL BLANKET • SOUND WALL. CONC. SLAB ON GRADE CAULK GYP. BD. TO FLOOR 0 ALL SOUND AND INEUL. WALLS INTERIOR DOOR JAMB SCALE: 1 -1/2" • 1' -0' SECTION D101- 3y7 SECTION REVIEWED FOR CODE COMPLIANCE APPROVED NOV 07 2012 City of Tukwila BUILDING DIVISION RECEIVED C :fYQ::TU( 11; OCT 2 6 2012 PERMIT CENTER C :Documents and Settinas\All UseraiDOCuments \CA 1312002\ ®225 RREFF1 Tenant ImnrnuamantnlT:,kwila P.nmmnrrs■ PariMMRI r112 etcYDCn 11 r vlann 4ft_na 4 71T_ a .a.... z 0 l= a it 0 0 A PAINT GYP BD REFER Y 40111P- — ==_== tip .... PAINT GYP BD 4" PLAM BAC SPLASH - ,ire„,..----- f 44410 L DRAILERS COUNT ELEV4TION "'"`""""" SCALE: 3/8' t 114:1 NOTES: CABINETRY TO BE FLUSH OVERLAY, PLASTIC LAMINATE INSIDE TO HAVE KORTRON FINISH HARDWARE TO BE CONCEALED HINGES, EUROPEAN,26D WIRE PULLS TO BE 26D FINISH DRAWER GUIDES TO EE METAL, SELF CLOSING ADJUSTABLE SHELVING OUTLETS TO BE 444" TO CENTER (MI5$ BACKSPLASH) ROOF STRUCTURE GLB1PURLM OR STIFFENER + I/2" SPACE GYP.BD. TO GYP. 8D. EA. SIDE \74>: ALT.1 -1EAD DETAIL. SCALE: I.1/2" , 1' -0" MINIM OMNI 6" DEEP LEG CRACK ATTACH TO GL.B. W/3 1 5/8" SCREWS • 2' -0' OTC. (DEEP LEG IS 3 ") STUDS 20 GA • 2' -0" C.C. NOT ATTACHED TO TRACK BUT LAPPED up INSIDE 1 ". GYP.BD. ATTACHED TO STUD -NOT TO STRUCTURE OR TRACK SECTION FOR WALLS GREATER THAN S'- 0" IN WIDTH WITHOUT AN INTERSECTING WALL, PROVIDE 12Sa. WIRES SPLAYED • 45 t0 AN EYE SCREW • ROCF ANp Top OF WAL '■ ■■■■■■■■■■■■■■1111111r,■■ ■■■■■■■■■► ATTACH TOP RUNNER TRACK TO CEILING GRID WITH 2 - Ya x 1 IV LONG SCREWS AT 2' -0" O.C. TYPICAL STUDS - 3 5/8", 25G,A. STEEL • 24" O.C. (FOR WALL INSULATION SEE MAW '5 /S" GYP. BD. EA SIDE (FLUSH FINISH). sEg REFLECTED CEILING PLAN Imp TYPICAL WALL HEAD TO $USPENDWD CEILING SCALE; 1- v2. "I' TYPICAL. WALL FRAMING ATTACH BOTTOM TRACK TO CONC. FLOOR W/ POWDER DRIVEN ANCHORS, HILTI OR APPROVED I" EMBEDMENT AT 24" Q.C. 2 1/2" RUBBER BASE • CARPET 4 4 4 IU4LL TQ SAAB SCALE: . 11-0" WOOD DOOR HOLLOW METAL DRY WALL FRAME (MATCH EXISTING) 54" G. 8D. BOTH SIDES STEEL STUDS 5/8" GYP. BD. (TYPE 'X' 0 FIRE RATED WALLS.) ACOUSTICAL BLANKET • SOUND WALL. CONC. SLAB ON GRADE CAULK GYP. BD. TO FLOOR 0 ALL SOUND AND INEUL. WALLS INTERIOR DOOR JAMB SCALE: 1 -1/2" • 1' -0' SECTION D101- 3y7 SECTION REVIEWED FOR CODE COMPLIANCE APPROVED NOV 07 2012 City of Tukwila BUILDING DIVISION RECEIVED C :fYQ::TU( 11; OCT 2 6 2012 PERMIT CENTER C :Documents and Settinas\All UseraiDOCuments \CA 1312002\ ®225 RREFF1 Tenant ImnrnuamantnlT:,kwila P.nmmnrrs■ PariMMRI r112 etcYDCn 11 r vlann 4ft_na 4 71T_ a .a.... z 0 l= a it 0 0 A