Loading...
HomeMy WebLinkAboutPermit D12-356 - CENTURY LINK - TENANT IMPROVEMENTCENTURY LINK 6101 S 180 ST D12 -356 City off ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3523049120 Address: 6101 S 180 ST TUKW Suite No: Project Name: CENTURY LINK DEVELOPMENT PERMIT Permit Number: D12 -3S6 Issue Date: 12/07/2012 Permit Expires On: 06/01/2013 Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKVVILA WA 98138 Contact Person: Name: LUKE HAGLER Address: 980 S HARNEY ST , SEATTLE WA 98108 Contractor: Name: CHARTER CONST INC Address: 980 S HARNEY ST , SEATTLE WA 98108 Contractor License No: CHARTCI171PM Lender: Name: Address: Phone: 206 - 382 -1900 Phone: 206 - 382 -1900 Expiration Date: 10/23/2014 DESCRIPTION OF WORK: INTERIOR UPGRADES TO CUSTOMER LOBBY SPACE, NEW FULL HEIGHT SECURITY WALLS, MODIFICATION TO CEILING, HEATING, VENTILATION, AND AIR CONDITIONING DISTRIBUTION SYSTEMS, FIRE ALARM SYSTEM WILL BE REQUIRED TO SERVE THE SECURITY VESTIBULES AND CONTROL DESK MONITORING. Value of Construction: $150,000.00 Fees Collected: $3,113.76 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: 1I -B Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -356 Printed: 12 -07 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Storm Drainage: Street Use: Profit: N Water Main Extension: Private: Water Meter: N Permit Center Authorized Signature: L1 l� Date: Public: Non - Profit: N Public: I hereby certify that I have read and ex- 'fled this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be compli _ • wit , whether specified herein or not. The granting of this permit does not p = • lime to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: 1 Print Name: TE� S RSTC N7 Date: %? -7- /z This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D12 -356 Printed: 12 -07 -2012 7: All construction shall be done in conform- a with the approved plans and the requirem of the International Building Code or International Residential , International Mechanical Code, Washingtdffirate Energy Code. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 nun) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 14: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 17: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 18: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 19: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 22: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 nun). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) doc: IBC -7/10 D12 -356 Printed: 12 -07 -2012 23: Exit signs shall be illuminated at all tim o ensure continued illumination for a duratio of not less than 90 minutes in case of primary power loss, the illumination means shall be connected to an rgency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1 .3) 24: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot -candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 25: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 26: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 28: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 29: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2328) 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 32: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -356 Printed: 12 -07 -2012 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 1r► � . �D Project No Date Application Accepted: t 1-- 3 1 Date Application Expires: 5-s- - ( (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: lv /a/ S> /8®T' St. `C'ra tLo -rcy `; a 14 King Co Assessor's Tax No.: 3 -3 L it9 /.7 ea "-/- PROPERTY OWNER Name: C.-"e- t- s"'/Ge. ry L1 ra k. Re. / S it •e- Address: 0.3'46►n,„4 6,.,->t„..^ jar.' ✓,:. City: E,1' /, ,,„ ..- ,/ State: cc, Zip: ���/ / a CONTACT PERSON — person receiving all project communication Name: L 41,...e. x.4`.7 je — Address: 98J S hi,.4rne ,31-. City: s.,..s I]t /e State: w4 Zip: 945' /cif. Phone:2 0i,, 3f31. /yo,:> Fax: 2c>‘.., . 3 s” 2., vS/S,0 Email: 14,ke h 4, ,, GJa r- frrco:. . ee*.+� GENERAL CONTRACTOR INFORMATION Company Name: 6/7,,, ,,„/ -e,, el,,.,s /,.,� e. "i!-, c,,... Address: ei8O S: jja,,, n et7 St, City: Se.4 die State: wri Zip: '8 /0* Phone: :206, 33 "Z • ll-IDG) Fax: ;104,• 3i 2 r p 45e, Contr Reg No.: efing7.42 i / 7 / pin Exp Date: /0 , 2 3 , iq Tukwila Business License No.: f3 ,S , D 9'34, -7c. H: \Applications \Forms - Applications On Line \2011 Applications \Permit Application Revised - 8 -9 -1 I.docx Revised: August 2011 bh Suite Number: Floor: New Tenant: ❑ Yes ARCHITECT OF RECORD Company Name: -Kt «hct�l 6„i14-'rJR,i1nc. Architect Name: t,Nikt Lee wi.x.t Address: 2eI-221 1.4 c, 4, „,l /1- 2. / S`4. +. 8vc> City: 'pile e n.t)e State: /tZ Zip: ,1 a, Phone: 6,62_„ Fax: /,,4, 2,2X9 • i'f11 Email:.rn`Ltt hew j La..w.nnte mb444.e-. -44.,rp , - th ENGINEER OF RECORD Name: -re., .. Company Name: Address: Engineer Name: Address: State: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED. (required for projects $5,000 or greater per RCW 19.27.095) Name: -re., .. •-1 f f„-+, e/e n/ Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION - 206- 431 -3670 Valuation of Project (contractor's bid price): $ /5C) o o Existing Building Valuation: $ Describe the scope of work (please provide detailed information): 1.1•arP -r-rJr^ Lip ,- o../c° -3 '� (•'rs 5 f"arYx'ICr /i©6boy .Sibe-s.�y,` �r'Hi fs[-i1 G/JLi�' Sr'C'sc., 40 /IS/ /Y7�sfr�4 %�eh fv Lta� /%�.c` / "/7C...'/t 5, Ue 1-..'/R>F7'v'M i Cre -f, N ;5 1,144 7 • i S. 9 c.. -i s ; f7 - , /st /' � -, S`/ S ~r'r. -. EJ �' / / ,b- r rra , ". Y d f► £ -° ez ai.^. �i 1/ i i%7�c �rS �r t G/ nor. l % G� <s� s - ..1 —i s r.`.�.• , Will there be new rack storage? ❑ Yes . No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION /HAZARDOUS MATERIALS: Compact: Handicap: ❑ No If "yes ", explain: Sprinklers f Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of ammable, combustible or hazardous materials in the building? ❑ Yes 1a No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \Applications\Forms- Applications On Line \201 1 Applications \Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I' Floor 6 /33 // / 33 0 P //-A. a 2nd Floor 3"1 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION /HAZARDOUS MATERIALS: Compact: Handicap: ❑ No If "yes ", explain: Sprinklers f Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of ammable, combustible or hazardous materials in the building? ❑ Yes 1a No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \Applications\Forms- Applications On Line \201 1 Applications \Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE R UTHOR D ENT: Signature: Print Name: Ste e_ 71.4e4. i1_ Mailing Address: 941" - f �. e% S/ H: \Applications \Forms - Applications On Line \2011 Applications \Permit Application Revised - 8 -9 -1 1.docx Revised: August 2011 bh Date: Day Telephone:.? "Co • ig 2 - /4T oe, X /5 Sc /WC ✓A `ie /v8 City State Zip Page 4 of 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3523049120 Address: 6101 S 180 ST TIIKW Suite No: Applicant: CENTURY LINK RECEIPT Permit Number: D12-356 Status: PENDING Applied Date: 11/05/2012 Issue Date: Receipt No.: R12 -03041 Payment Amount: $3,113.76 Initials: WER Payment Date: 11/05/2012 09:50 AM User ID: 1655 Balance: $0.00 Payee: CHARTER CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 25658 3,113.76 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $3,113.76 1,884.40 1,224.86 4.50 rinr: RPrpint -f1R PrintMrl• 11- ns_7f119 • INSPECTION NO. INSPECTION RECORD Retain a copy with permit (Z - -)Sly PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 ? t'• Project: C'FN/TIMti LINK Typ f Inspecti n: . I JJA-k J ( •• w t Address: n tc9 1 ';11 t X(�` Date Called: Special Instructions: Date Wanted: �a.�m„ Z —2-1 —r 3 p.m., Requester: Phone No: ` r 4s f3 ,4s.r roved per applicable codes. Corrections required prior to approval. COMMENTS: oWei t "c-b Fr1 r.J Date: t_ exe„ 2`%,— t —7 INSPECTION FEE REQUI D. Prior to n xt inspection. fee run e id at 6300 Southcenter Blvd., Suite 100. all to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 { (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 iZ -35,6 Proje �,.— L ‘ 4 �/ TYP 03 f Inspection: �� ( Y Add/ress: Y`^ st--- Date Called: Special Instructions: Date Wanted . - ! ' "J „A.m... (� ( p.m. Requester: W°7.o (0 --4 co _4s fp Approved per applicable codes. Corrections required prior to approval. COMMENTS: fito rr ; �d't .ibt1`_ Inspect Date _ / ? n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: d ,A7 3i L1 k. � - t TYp Inspection: � ct , (, -�t ' Addr ss: T. Date Called: Special Instructions: Date Wante i '--0 p.m. Requester: Phone No: ∎ -454 -°4S (g ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: (() f"i.ur v\AUe -kd\-- Nklot. (3T t,, WI co" pro '.ecx- L: t:t LEA---0 e c MA P wif z e pu 6l'i c__ wA--/ Ins . ector: Iz _ / ( - 1,3 n REINSPECTION FEE REQUIRED. ,nor l:o next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 (206) 431 -36710 Project: ilF%Vcis{ (..t+.1K Type of Inspection: i BUBO riC:It OfiLtnjits Address: C„tOl _�.9 ,+� IAe) S Date Called: . Special Instructions: Date Wanted:. 1 1‘-tom, a.m'. �m:. Requester: Phone No: 02QCn - ` -iSO- L/rs18 Approved perapplicable codes. Corrections required prior to approval. CO MENTS: Ipspect r: Wa"1'6,ir L c ~ct REI{JSPECTION FEE R QUIRED. rior to next inspection. fee must be p d at 6300 Southcenter Blvd.. quite 100. Call to schedule.reinspection. Date: 1-)6.' INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 x,(206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: OPa)iL.l24 LIrJR Type of Inspection: . FRAv iVJ(� Address: ! 0141 1460 Date Called: Special Instructions: Date Wanted:. 12-- 1-5 —I? 6..� = p.m. Requester: Phone No: a..O c o - L1 C . L 51 8 pproved per applicable codes. Corrections required prior to approval. COMMENTS: or: Ctot-i Date: SPECTION FEE REQU ED. Prior to r xt inspection. fee must be at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a. copy with permit Da- PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 f-^ Project: s A C ,ae /A/5 _Z5 ) /e`6. Type of Inspection: _, S Lrsr/C I7/O i) . Address: 6/01 S /SD �.s—i----- Date Called: . • Special Instructions: �oG- 382-/� Date Wanted; . /a /3 / ' 2 a. m. iKe Requester: (44 ?�2 (� Vy/kI1a- j Phone No: 6 Y , ?• / ? , 4 0 1 ) , V • ElApproved per applicable codes. • 10 Corrections required prior to approval. COMMENTS : k S 7��fI PP; U� TO V '/ft1 hi- ,ae /A/5 _Z5 ) /e`6. L// - 7 i(h? 4/% Gr l(11?X" ; 7A/774 -_ / 5 i55rvf./ ?/N /"..-(.4.) 4f-- " CJ5 .__57o P aid Q k e41/1/ S f 1 SS2.tre _,,L A/07 /70.1,-> P. /4 08) /-2/9 2 nspe r: / �C Date' INSPECTION FEE RECUIRED. P or to next inspection, fee must be. paid at 6300 Southcenter Blvd.. S Ite 100. Call to schedule reinspeCtioh. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: C.:.Aurc� L, afk Type of Inspection: k -e .i ") t4L Address: 61 o ! Suite #: 5 j N)$'— Contact Person: Special Instructions: Permits: _ Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: VituArL r-e- Q. w _ (K Needs Shift Inspection: Sprinklers: . Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: _ Occupancy Type: Inspector: A. d_ Date: 21/9//5 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: 1 Company Name: Address: City: State: 1 Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /3 -S -Oc 9- bra- 33-4:7 PERMIT NUMBERS .; • . E CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: �,J to r i �— r a/ k. Sprinklers: Type of Inspection:\ 7) P C.00 -.e2 \ r iI A Lj Address'610-1 Suite #: 5 /8.°-4.....— Contact Person: I- tit,l<e ` ( _er Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: a ` Monitor: Pre -Fire: Permits: Occupancy Type: SP ciNaaL a oIc._ ii1 -C il ( .3 f Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 1FN 42 Date: 1/k, / / 3 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You 411 receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • • • o • City of Tukwila Department of Community Development 6300 Southcenter Blvd, STE #100 Tukwila, WA 98188 Attn: Mr. Bill Rambo Re: Permit Application #D12 -356; Plan review comment responses Michael Baker Jr., Inc. 2929 North Central Avenue Suite 800 Phoenix, AZ 85012 602.279.1234 602.279.1411 Fax RECCEIVEU CITY OF TUKL A NOV 2 % 2012 PERMIT CENTER Mr. Rambo; Please see the following responses to the review comments for D12 -356. Thank you for your supportive comments. All comment responses are identified by clouds on the drawings and labeled with delta 1. Below are the written responses to each comment. 1. Please provide details for the operational controls of door number 0102, D103A and D103B. The sections listed below are IBC code allowed methods for specific door operations. • Section 1008.1.4.4 Access controlled egress doors • Section 1008.1.9.7 Delayed egress locks • Section 1008.1.9.8 electromagnetically locked egress doors Each of these code sections has a specific list of requirements. Please show the applicable section proposed for each door on the plans and also show the requirements for the failsafe operation of the method used as spelled out in the .code section. Please see revised sheet A -601 for a description of each hardware set including the compliant code section to address each of the sections listed above. Also enclosed is the preliminary shop drawing from the security consultant detailing the operational controls. 2. Door 103B has a box symbol on the inside of the man -lock with a BR in it. I could not find this symbol in the legend on sheet E -001. Please see revised sheet E -001. The symbol has been added. 3. The area shown on A -102 has a combined occupant load exceeding 50 and would require two exits from this space. The second exit is not obvious but may be through Hallway 2 and out the door that swings in the direction of travel. Please confirm the second exit and show exit signage as existing or new if needed. Please see revised sheets G -102 and G -103. We are only adding 2 occupants by changing the current Equipment Room 108 to a Touch Down area. Please notice a more extensive exit analysis on the 2 noted sheets above. 4. The alteration of this area involves the main egress path an emergency lighting will need to be shown along this path connecting the two exits. The path should split and include both the man -lock and the bypass through door 102. Please add a note that states the required normal and emergency lighting levels as required per section 1006 IBC. Please see revised Sheet E -104 for added keynote 29 and revised Hallway 107 lighting layout. Please do not hesitate to contact Bruce Preston at 602 - 798 -7515 if any clarifications are required for the responses above. Thank youu,,,�` Bruce Preston DBIA, LEED AP BD +C Project Manager Michael Baker Jr., Inc CITY OAUKWILA NOV 2 7 2012 PERMIT CENTER • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director November 13, 2012 Luke Hagler Charter Construction 980 S Harney St Seattle, WA 98108 RE: Correction Letter #1 Development Permit Application Number D12 -356 Century Link — 6101 S 180 St Dear Mr. hagler, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building, Fire, and Public Works Departments. At this time the Planning Department has no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File No. D12 -356 W:\Permil Center \Correction Letters \2012 \D12 -356 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: November 8, 2012 Project Name: Century Link Permit # D12 -356 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Please provide details for the operational controls of door number D102, DIO3A and D103B. The sections listed below are IBC code allowed methods for specific door operations. • Section 1008.1.4.4 Access controlled egress doors • Section 1008.1.9.7 Delayed egress locks • Section 1008.1.9.8 Electromagnetically locked egress doors Each of these code sections has a specific list of requirements. Please show the applicable section proposed for each door on the plans and also show the requirements for the failsafe operation of the method used as spelled out in the code section. 2. Door 103B has a box symbol on the inside of the man -lock with a BR in it. I could not find this symbol in the legend on sheet E -001. 3. The area shown on A -102 has a combined occupant load exceeding 50 and would require two exits from this space. The second exit is not obvious but may be through Hallway 2 and out the door that swings in the direction of travel. Please confirm the second exit and show exit signage as existing or new if needed. 4. The alteration of this area involves the main egress path an emergency lighting will need to be shown along this path connecting the two exits. The path should split and include both the man - lock and the bypass through door 102. Please add a note that states the required normal and emergency lighting levels as required per section 1006 IBC. Should there be questions concerning the above information please contact the Building Division at 206- 431 -3670. •PERMIT COARD COPT PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -356 DATE: 11/27/12 PROJECT NAME: CENTURY LINK SITE ADDRESS: 6101 S 180 ST Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Fig Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11/29/12 Complete 171) Incomplete ❑ Not Applicable ❑ Comments: PermitCenter Use.Only ' • . ' • °r • INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required No further Review Required I I APPROVALS OR CORRECTIONS: DUE DATE: 12/27/12 Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Not Approved (attach comments) ❑ DATE: • Permit' Ce'riterUse'Only. '•:,"',' ti's•• ".''x::�`i;: 1: x .. ;� . . • CORRECTION LETTER MAILED: M., • Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: O PE CO PLAN REVIEW • OU ING SLIP ACTIVITY NUMBER: D12 -356 PROJECT NAME: CENTURY LINK SITE ADDRESS: 6101 S 180 ST X Original Plan Submittal _ Response to Correction Letter # DATE: 11 -05 -12 Response to Incomplete Letter # _ Revision # After Permit Issued DEPAR MENT : i din lAi sion' ubIic Wo' rrkkss ire Prevention Structural anning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -06 -12 Complete Incomplete n Not Applicable Comments: Permit Center Use Only. • INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ LETTER OF COMPLETENESS MAILED: Ping ❑ PW ❑ Staff Initials: TUESITHURS ROUTING: Please Route 1p Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 12 -04 -12 Not Approved (attach comments) Nr ..Permit.Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: \'1J-- 112, Bldg le Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 d • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: // * 2-7 ` / z- Plan Check/Permit Number: D12-356 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # _ / after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Century Link Project Address: 6101 S 180 St Contact Person: L/- ke 11/4c, C-- Phone Number: .2 ° -- 3 h Z - I do QV N 2 i 2012 °EHMirCENTER Summary of Revision: I Ika,e sc.d. ctla't.A -IoG1 - 2 — 5 €- ,k -1 1 c' sec 5 4.4s lo 2. R G -to3 $mac She 6 i E - /o ,' ,^ a 144 •et,G-r, / ,dao 4150 ?) a,►•. !my :e'...5 (l M`t S ie� ,s.c. % e H `•^ Lett}m.g..1 .fps" Al W% Q.)G X6:1%1! L��t teaTi'O� 70 tit. C. aN�: N.' 7�& STaaa+es Sheet Number(s): ` "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on II \, Iii t C \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople Prlter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name CHARTER CONST INC UBI No. 600479166 Phone 2063821900 Status Active Address 980 5 Harney Street License No. CHARTCI171 PM Suite /Apt. License Type Construction Contractor City Seattle Effective Date 10/14/1983 State WA Expiration Date 10/23/2014 Zip 981082744 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TELESGI179JDTELESIS GROUP INC, THE Construction Contractor General Unused 4/4/1983 4/4/1984 Archived Business Owner Information Name Role Effective Date Expiration Date SALADINO, PETER CARROLL President 02/17/2011 Amount COSENTINO, PATRICK Vice President 02/17/2011 SLPGGL0121001 JACKSON, ERIC Vice President 02/17/2011 FIRMANI, FRANK President 10/14/1983 02/17/2011 SALADINO, PETER C Vice President 10/14/1983 02/17/2011 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 6 TRAVELERS CAS Et SURETY CO 081S103572915BCM 07/22/2001 Until Cancelled $12,000.00 10/18/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 29 Starr Surplus Lines Insurance SLPGGL0121001 11/01/2012 11/01/2013 $1,000,000.00 10/31/2012 28 Starr Surplus Lines Insurance SLPGGL0121000 11/01/2011 11/01/2012 $1,000,000.00 11/01/2011 27 Starr Surplus Lines Insurance SR98011279455 11/01/2011 11/01/2012 11/01/2011 $1,000,000.00 10/31/2011 26 STEADFAST INS GPL982931400 11/01/2010 11/01/2011 $1,000,000.00 10/29/2010 25 FIRST MERCURY INS CO FMWA0004122 11/01/2009 11/01/2010 $1,000,000.00 10/30/2009 24 FIRST MERCURY INS CO fmwa000412 11/01/2008 11/01/2009 $1,000,000.00 10/31/2008 23 FIRST MERCURY INS CO FMFL003259 11/01/2007 11/01/2008 $1,000,000.00 10/30/2007 22 FIRST INS MERCURY FMFL002201 11/01/2006 11/01/2007 $1,000,000.00 11/01/2006 https://fortress.wa.gov/lni/bbip/Print.aspx 12/07/2012 betlrig CenturyLink REAL ESTATE TUKWILA CYBER - INTERIOR UPGRADES 6101 SOUTH 180TH. STREET TUKWILA, WA. 98188 PARCEL No. 3523049120 C7aD Mantrap & Branding Upgrade De /1 AREA OF WORK SM 3 KEY PLAN SCALE: 1" = 80' -0" LOCATION MAP SCALE: N.T.S. E rtiVI" �9 IT \.r •�.I�6'il Ui T : PERM =OrfED FOR: i l' echanicai (1Clectrical eiumbing as Piping City of Tukwila BUR.DiNG DIVISION GENERAL NOTES 1. ALL WORK OF THE GENERAL. CONTRACTOR AND HIS SUBCONTRACTORS (HEREIN REFERRED COLLECTIVELY AS THE CONTRACTOR) SHALL CONFORM TO THE PROVISIONS OF THE FEDERAL, STATE, CITY, AND COUNTY BUILDING LAWS, ORDINANCES, RULES AND REGULATIONS. 2. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND LICENSES AND GIVE ALL NECESSARY NOTICES. THE OWNER SHALL PAY COSTS OF ALL INCIDENTAL FEES - INCLUDING THE CERTIFICATE OF OCCUPANCY. 3. THE CONTRACTOR SHALL MAINTAIN ADEQUATE PROTECTION OF ALL HIS WORK FROM DAMAGE, AND SHALL PROTECT THE OWNER'S PROPERTY, ADJACENT PROPERTY, AND PUBLIC PROPERTY FROM DAMAGE AND INJURY ARISING IN CONNECTION WITH THIS CONTRACT, AND SHALL MAKE GOOD ANY SUCH DAMAGE OR INJURY AT NO COST TO THE OWNER. 4. THE CONTRACTOR SHALL WARRANT AND GUARANTEE ALL MATERIALS AND WORKMANSHIP, FOR ALL PORTIONS OF THE WORK, FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL COMPLETION AND ACCEPTANCE BY THE OWNER, AND SHALL REPAIR OR REPLACE ALL WORK THAT BECOMES DEFECTIVE, AT NO ADDITIONAL EXPENSE. 5. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE BEST SKILL AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCE AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 6. UNLESS NOTED OTHERWISE, THE CONTRACTOR SHALL PROVIDE AND PAY FOR ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT AND MACHINERY, TRANSPORTATION, AND OTHER FACILITIES AND SERVICES NECESSARY FOR PROPER EXECUTION AND COMPLETION OF WORK. 7. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, CLEARANCES AND FIELD CONDITIONS. REPORT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. 8. ALL PENETRATIONS THROUGH WALLS AND FLOORS SHALL BE SEALED WITH FIRE STOPPING MATERIAL AS REQUIRED TO ACHIEVE THE RESPECTIVE FIRE - RESISTIVE RATING AND SMOKE STOPPAGE, AS REQUIRED BY LOCAL BUILDING CODES. 9. THE CONTRACTOR SHALL COORDINATE AND VERIFY ALL MECHANICAL, ELECTRICAL AND PLUMBING PORTIONS OF THE WORK, AND THE LOCATIONS OF ALL PIPING, DUCTWORK, TRENCHES, SLEEVES, SPECIAL BOLTING FOR EQUIPMENT, CONDUITS, ETC., THROUGH AND UNDER CONCRETE SLABS PRIOR TO POURING OF FOOTINGS AND FLOOR SLABS. THE CONTRACTOR SHALL VERIFY UTILITY LOCATIONS 10. THE CONTRACTOR, AND ALL OTHERS PROVIDING WORK OR MATERIALS SHALL PROVIDE AND MAINTAIN COMPLETE WORKMAN'S COMPENSATION AND OTHER NECESSARY INSURANCE (EXCEPT ALL RISK" INSURANCE). PROVIDE CERTIFICATES PRIOR TO COMMENCING WORK. 11. THE CONTRACTOR SHALL KEEP THE PROJECT WORK IN A CLEAN AND ORDERLY FASHION AT ALL TIMES DURING CONSTRUCTION. UPON COMPLETION OF EACH STAGE (OR DAILY), LEAVE ALL WORK AREAS AND FINISHED SPACES "BROOM CLEAN" AND IN ACCEPTABLE CONDITION. 12. THE DESIGN ADEQUACY AND SAFETY OF ERECTION, BRACING, SHORING, TEMPORARY SUPPORT, ETC., ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 13. THE CONTRACTOR'S PRICES SHALL INCLUDE ALL LOCAL TAXES, DELIVERY AND INSTALLATION COST. 14. THE USE OF BRAND TRADE NAMES IN DESCRIBING MATERIALS OR PRODUCTS IS INTENDED TO SET MINIMUM STANDARDS FOR THOSE ITEMS; HOWEVER, ANY SUBSTITUTION MUST BE APPROVED BY MICHAEL BAKER JR. INC. IN WRITING BEFORE BEING USED IN THE WORK. 15. DIMENSIONS NOTED AS "CLEAR' SHALL BE FROM FINISHED MATERIAL FACE. ALL DIMENSIONS TO STUD WALLS ARE TO FACE OF STUD. ALL DIMENSIONS TO MASONRY OR CONCRETE WALLS ARE TO FACE OF MASONRY OR CONCRETE. DIMENSIONS TO STRUCTURAL MEMBERS SUCH AS BEAMS AND OR COLUMNS ARE TO CENTERLINE OF STRUCTURAL MEMBER. 16. GENERAL CONTRACTOR IS RESPONSIBLE TO MAINTAIN A CURRENT SET OF DRAWINGS ON SITE AT ALL TIMES AND TO ENSURE THE DISTRIBUTION OF NEW DRAWINGS TO SUB - CONTRACTORS AND OTHER RELEVANT PARTIES AS SOON AS THEY ARE MADE AVAILABLE. 17. RECORD DOCUMENTS: UPON COMPLETION OF THE PROJECT, CONTRACTOR SHALL PROVIDE OWNER AND TENANT WITH A COMPLETE SET OF RECORD DOCUMENTS INCLUDING RECORD DRAWINGS, A LIST OF SUBCONTRACTORS USED ON THE PROJECT, MANUFACTURERS WARRANTIES, OPERATION AND MAINTENANCE MANUALS FOR MAJOR PIECES OF EQUIPMENT, AND INSTRUCTION MANUALS WHEN APPROPRIATE FOR BUILDING SYSTEMS. 18. DIMENSIONS INDICATED IN CONTRACT DOCUMENTS SHALL GOVERN. DO NOT SCALE DRAWINGS. 19. PROVIDE 2A -108:C FIRE EXTINGUISHERS WITH TRAVEL DISTANCE NOT TO EXCEED 75' IN ACCORDANCE WITH NFPA STANDARDS, AS DIRECTED BY THE FIRE MARSHAL. 20. THE USE OF THE WORD "PROVIDE' IN CONNECTION WITH ANY ITEM SPECIFIED IS INTENDED TO MEAN THAT SUCH SHALL BE FURNISHED, INSTALLED, AND CONNECTED BY THE CONTRACTOR, WHERE SO REQUIRED. NOTICE OF EXTENDED CERTIFICATION AND APPROVAL PERIOD PROVISION THIS CONTRACT ALLOWS THE OWNER TO CERTIFY AND APPROVE BILLINGS ESTIMATES WITHIN 30 DAYS AFTER THE BILLINGS AND ESTIMATES ARE RECEIVED FROM THE CONTRACTOR. NOTICE OF EXTENDED PAYMENT PROVISION THIS CONTRACT ALLOWS THE OWNER TO MAKE PAYMENT WITHIN 45 DAYS AFTER CERTIFICATION AND APPROVAL OF BILLINGS AND ESTIMATES. SCOPE OF WORK DESCRIPTION: THE DATA CENTER IMPROVEMENTS INCLUDE THE ADDITION OF SECURITY VESTIBULES AT PRIMARY ENTRY POINTS ONTO THE DATA CENTER FLOORS AND THE ADDITION OF OR MODIFICATIONS TO SECURITY CONTROL DESK AND MONITORING POINTS AT THE ENTRY OF THE DATA CENTER. THE DESIGN OF MODIFICATIONS WILL INCLUDE: INTERIOR UPGRADES TO THE CUSTOMER LOBBY SPACES; HEATING, VENTILATION, AND AIR CONDITIONING DISTRIBUTION SYSTEMS; AND FIRE ALARM SYSTEMS THAT WILL BE REQUIRED TO SERVE THE SECURITY VESTIBULES AND CONTROL DESK MONITORING POINTS. CODE INFORMATION TOTAL FLOOR AREA NO CHANGE. REMAIN EXISTING REMODELED AREA = 1,133 S.F. BUILDING CODES OBSERVED: 2009 IBC 2009 IMC 2009 IFC CONSTRUCTION TYPE (PER IBC): TYPE: II-B OCCUPANCY TYPE: B REVISIONS No chimes shall be made to the scope of work without prior approval of Y °'zw to Building Division. require a new plan submittal 4 addlional plan review fees. CONSULTANT FIRM MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 PROJECT TEAM OWNER: CENTURYLINK REAL ESTATE 15674 VIKING GLOVE LANE VALLEY CENTER, CA. 92082 CONTACT: BRIAN BACHMAN PH: 760.751.5459 e-mail: Brian.Bachman@CenturyLink.com ARCHITECT: MICHAEL BAKER JR. INC. 2929 N. CENTRAL AVENUE SUITE 800 PHOENIX, AZ. 85012 CONTACT: MATT LAMONT, RA, NCARB OPERATIONS DIRECTOR PH: 602.798.7546 FAX: 602.279.1411 e -mail: Matthew.Lamont@mbakercorp.com CONTACT: BRUCE PRESTON PROJECT MANAGER PH: 602.798.7515 e -mail: bpreston @mbakercorp.com MECH., ELECT. & PLUMING: CEC - COMMUNICATIONS ENGINEERING CONSULTANTS 6820 LAUFFER ROAD COLUMBUS, OHIO 43231 CONTACT: MICHAEL LOY PH: 614.392.2907 e-mail: michael.by @cedimited.com SECURITY: STANLEY SECURITY SOLUTIONS 7399 SOUTH TUCSON WAY SUITE A-6 CENTENNIAL, COLORADO 80112 CONTACT: ED MCMURRER ACCESS CONTROL AND SURVEILLANCE SYSTEM CONTRACTOR PH: 303.232.5600 e-mail: Ed.Mcmurrer@sbdinc.com SHEET INDEX GENERAL G-101 COVER SHEET G-102 OVERALL EXIT ANALYSIS PLAN G-103 ENLARGED EXIT ANALYSIS PLAN ARCH! CTURAL A-001 ABBREVIATIONS & GENERAL NOTES A-101 DEMOLITION FLOOR & RCP PLANS A-102 NEW FLOOR & RCP PLANS A-103 ENLARGED FINISH FLOOR PLAN A-501 PARTITION TYPES & DETAILS A-502 ARCHITECTURAL DETAILS A-601 SCHEDULES & DETAILS MECHANICAL M-001 ABBREVIATIONS & GENERAL NOTES M-101 DEMOLITION MECHANICAL & FP PLANS M-102 MECHANICAL & FP PLANS M -103 DEMOLITION MECHANICAL & FP PLANS M-104 MECHANICAL & FP PLANS PLUMBING P -101 PLUMBING PLAN ELECTRICAL E-001 ABBREVIATIONS & GENERAL NOTES E -101 DEMOLITION FLOOR & RCP PLANS E -102 NEW FLOOR & RCP PLANS E -103 DEMOLITION FLOOR & RCP PLANS E -104 NEW FLOOR & RCP PLANS FM COPY Pe o. n �o P!-- r -•,b= " J 22pprovai is subject to errors and omissions. I, CY c;orntruotion documents does not autthc s L. , tJ. t`'i adopted coda or ordinance. Roco;pt 0. ea;. JVv iv.fzi V(q • t �. ' is acknowledged: • By Date: , ` 4Z- -- City Of Tukwila BUILDING DIVISION CORRECTION LTR #. REVIEWED FOR CODE COMPLIANCE APPROVED 1 DEC 0 5 2012 b L — City of Tukwila BUILDING DIVISION RECttvEi) CITY OF TUKWILA NOV 2 7 2012 PERMIT CENTER CenturyLink CEO LOC D FLOOR FIRST "'DING "I'UKWILA CYBER - INTERIOR UPGRADES STREET ADDRESS 6101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRIPTION COVER SHEET STAMP ISSUED FOR CONSTRUCTION PERMIT REVISIONS CONSULTANT NAME NOTICE The information contained herein shoild not be disclosed b unauthorized persons. B b meant for use by authorized representatives of CenYstLHk• No. DESCRIPTION DATE DRAWN BY AP A CITY COMMENTS 11/19/2012 DATE 10112/12 CHECKED BY BP CASE NUMBER .JOB NO. 128296 REVISED BY BP /AP SCALE N.T.S. FILE NAME SHEET NO. 1 1:100 BUSINESS AREA = 4,413 S.F. RATIO - 1:100 PROJECT SYMBOLS xxxxxx XXXX XX This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 30' 130 30 1:300 0.15X45= 7" REQUIRED 72" PROVIDED EQUIPMENT (E) OCCUPANT LOAD NO CHANGE IN OCCUPANC OR OCCUPANT COUNT --I 3�C7 CODE INFORMATION TOTAL FLOOR AREA: NO CHANGE. REMAIN EXISTING REMODELED AREA =1,133 S.F. BUILDING CODES OBSERVED: 2009 IBC 2009 IMC 2009 IFC CONSTRUCTION TYPE (PER IBC): TYPE: 11-8 OCCUPANCY TYPE: B 1:300 MECHANICAL (E) OCCUPANT LOAD NO CHANGE IN OCCUPANCY OR OCCUPANT COUNT OVERALL EXIT ANALYSIS PLAN SCALE: 1" = 30' -0" SYMBOL LEGEND BUSINESS AREA - NO (E) LOAD CHANGE • 1 x'-x" I EXTERIOR ELEVATION WITH SHEET NUMBER PARTIAL ELEVATION WITH SHEET NUMBER INTERIOR ELEVATION WITH SHEET NUMBER DETAIL WITH SHEET NUMBER SECTION WITH SHEET NUMBER NOTE SYMBOL ROOM NAME DOOR NUMBER WINDOW NUMBER CEILING HEIGHT ABOVE FINISHED FLOOR (A.F.F.) DATUM ELEVATION REVISION NORTH ARROW WALL TYPES REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2012 City of Tukwila BUILDING DIVISION RECtivtu CITY OF TUKWIt.A NOV 2 7 2012 PERMIT CENTER MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 STAMP CONSULTANT FIRM 1 CenturyLink GEOLOCD FLOOR FIRST BUILDING TUKWILA CYBER - INTERIOR UPGRADES STREET ADDRESS 6101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRFf10N OVERALL EXIT ANALYSIS PLAN ISSUED FOR CONSTRUCTION PERMIT REVISIONS DESCRIPTION CITY COMMENTS CONSULTANT NAME NOTICE The information contained herein should not be did b unauthorized persona it is meant for use by authorized represeniatIves of CenhuyLNk. DATE 11/1W2012 DRAWN BY DATE REVISED BY SCALE AP 10/12/12 BP BP /AP 1"=301-0" CASE NUMBER FILE NAME JOB NO 128296 P: 1Project1128296 _CenturyLink_NDC_Tukwila105 Deliverables101 Drawings108 rchitecturelTukwila G102.dwg [36X24] Nov 21, 2012 - 10:34am Initials: ARNOLD.PALACIOS M M M - M M - - M - - - - - - - M M = M - - M • ■ M M1 1:300 EQUIPMENT (E) OCCUPANT LOAD NO CHANGE IN OCCUPANCY OR OCCUPANT COUNT ...NNW MIMI MIN MEN =NM IMO - NEIN •11•11 I■1 NEN INN.. NEM MIN 4, 81 NMI' NNW - MN 1 1 1 1 1 1 1 4C11).4./ 1 1 1 1 1 1 1 1 1 1 L Lip o 32 ■"■ EXIT 1:100 BUSINESS AREA = 4,413 S.F. filkfIetteer OLC • 45 OCCUrANT3 0.15 X45 = 7" REQUIRED 77 PROVIDED MEN MINI NEN INNEN /6■ 11•11111 MINI MINI MIN MINI 45L CODE INFORMATION TOTAL FLOOR AREA: NO CHANGE. REMAIN EXISTING REMODELED AREA = 1,133 S.F. BUILDING CODES OBSERVED: 2009 IBC 2009 IMC 2009 IFC CONSTRUCTION TYPE (PER IBC): TYPE: II-B OCCUPANCY TYPE: B SYMBOL LEGEND EXIT fi 4 BUSINESS AREA - NO (E) LOAD CHANGE MIN= MIN MINI NUM MIN =M MINI MN MIMI MIN IIIIM 111111111 - NNE 11111111MI 1:300 MECHANICAL (E) OCCUPANT LOAD NO CHANGE IN OCCUPANCY OR OCCUPANT COUNT MIMI MIS MMM MIN 11•111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 .11 ENLARGED EXIT ANALYSIS PLAN SCALE: 1/8 Re.. u e41&4 e 4 1 ,31.-7 0 a 1 Ft? 1-e-m /6v6 I h+1)5 -lied 4. ti (.4 U./ft- 35-0 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 05 2012 City &Tukwila BUILDING DIVISION KEY PLAN SCALE: N.T.S. REGtivLi.) CITY OF TUKVV1t A NOV 2 7 2012 PERMIT CENTER CONSILTANT FIRM MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE 800 PHOENIX, ARIZONA 85012 (602) 279-1234 -.CenturyLink GEO LOC ID FLOOR FIRST BuLDING"*TUKWILA CYBER - INTERIOR UPGRADES SWEET ADDRESS 6101 SOUTH 180TH. STREET CRY, STATE TUKWILA, WA. 98188 DESCRIPTION ENLARGED EXIT ANALYSIS PLAN STAMP ISSUED FOR CONSTRUCTION PERMIT REVISIONS CONSULTANT NAME NOTICE The Infomudion contained herein should not be disdosed b unauthorized persons. It 13 meant for use by authorized represenlathes o CenturyLlnk. No. DESCRIPTION DATE DRAWN BY AP CASE NUMBER CRY COMMENTS 11/1912012 DATE 10/12/12 CHECKED BY BP JOB NO. FLE NAME REVISED BY BP/AP SCALE 1/8"=11-0" 128296 SHEET N° G-103 J, This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 GENERAL NOTES 1. COMPLY WITH CODES, LAWS, ORDINANCES, RULES, AND REGULATIONS OF PUBLIC AUTHORITIES GOVERNING THE WORK. 2. OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES GOVERNING THE WORK. 3. REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND CONFIRM THAT WORK IS BUILDABLE AS SHOWN. REPORT ANY CONFLICTS OR OMISSIONS TO THE ARCHITECT FOR CLARIFICATION PRIOR TO PERFORMING ANY WORK IN QUESTION. 4. SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION. 5. COORDINATE WORK WITH THE OWNER, INCLUDING SCHEDULING TIME AND LOCATIONS FOR DELIVERIES, BUILDING ACCESS, USE OF BUILDING SERVICES AND FACILITIES, AND USE OF ELEVATORS. MINIMIZE DISTURBANCE OF BUILDING FUNCTIONS AND OCCUPANTS. 6. OWNER WILL PROVIDE WORK NOTED BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION. 7. COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM INSTALLATIONS. 8. MAINTAIN EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS IN CONFORMANCE WITH CODES AND ORDINANCES. 9. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. 10. MAINTAIN WORK AREAS SECURE AND LOCKABLE DURING CONSTRUCTION. COORDINATE WITH TENANT AND LANDLORD TO ENSURE SECURITY. 11. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, CONSULT THE ARCHITECT. 12. PARTITIONS ARE DIMENSIONED FROM FACE OF STUD TO FACE OF STUD, UNLESS OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED "CLEAR ". ALLOW FOR THICKNESS OF FINISHES. 13. COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS. 14. WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION, RELOCATE PANELS TO ALIGN WITH AND FIT WITHIN NEW CONSTRUCTION. 15. UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4" INCH, UNLESS NOTED OTHERWISE. FIRE DEPARTMENT NOTES 1. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2A -IOB:C WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR, AND ADDITIONAL EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR OR BUILDING DEPARTMENT INSPECTOR. 2. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON DRAWINGS, AND ADDITIONAL SIGNS AS REQUIRED BY BUILDING DEPARTMENT INSPECTOR OR FIRE DEPARTMENT FIELD INSPECTOR. CONNECT EXIT SIGNS TO EMERGENCY POWER CIRCUITS. COMPLY WITH BUILDING CODES. 3. PROVIDE EMERGENCY LIGHTING OF ONE FOOT -CANDLE AT FLOOR LEVEL. COMPLY WITH BUILDING CODES. 4. MAINTAIN ISLES AT LEAST 44" WIDE AT PUBLIC AREAS. 5. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES. 6. DOORS OPENING INTO REQUIRED 1 -HOUR, FIRE - RESISTIVE CORRIDORS SHALL BE PROTECTED WITH A SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20- MINUTE RATING AND SHALL BE SELF -CLOSING. 7. 20- MINUTE DOOR JAMBS TO BE TIGHT - FITTING, SMOKE AND DRAFT CONTROLLED. 8. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE PERSONS AND IN ANY HAZARDOUS AREA. 9. INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDOR SHALL NOT EXCEED AN END POINT FLAME SPREAD RATING: A. CLASS A, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS INSTALLED IN VERTICAL EXITS. B. CLASS B, FLAME SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS INSTALLED IN HORIZONTAL EXITS. C. CLASS C, FLAME SPREAD 76 -200, SMOKE DENSITY 450, FOR MATERIALS INSTALLED IN ANY OTHER DIRECTION 10. DECORATIONS (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) SHALL BE NON - COMBUSTIBLE OR BE FLAME PROOFED IN AN APPROVED MANNER 11. PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE -RATED WALLS OR CEILINGS. 12. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS, FLAMMABLE GAS AND HAZARDOUS SUBSTANCES SHALL COMPLY WITH UNIFORM FIRE CODE REGULATIONS. 13. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE CODE REQUIREMENTS. 14. EXTEND OR MODIFY EXISTING FIRE/LIFE SAFETY SYSTEM AS REQUIRED TO PROVIDE AN APPROVED FIRE/LIFE SAFETY SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT WITH COMPLETE DESCRIPTION OF SEQUENCE OF OPERATION, AND OBTAIN APPROVAL PRIOR TO INSTALLATION. 15. LOCATE THE CENTER OF FIRE ALARM INITIATING DEVICES 48" ABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK. 16. EMERGENCY WARNING SYSTEMS SHALL ACTIVATE A MEANS OF WARNING THE HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY OF NOT MORE THAN 60 FLASHES PER MINUTE. 17. EXTEND OR MODIFY EXISTING AUTOMATIC FIRE EXTINGUISHING SYSTEM AS REQUIRED TO PROVIDE AN APPROVED AUTOMATIC FIRE EXTINGUISHING SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT AND OBTAIN APPROVAL PRIOR TO INSTALLATION. 18. AUTOMATIC SPRINKLER SYSTEMS SHALL BE SUPERVISED BY AN APPROVED CENTRAL, PROPRIETARY OR REMOTE STATION SERVICE OR A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE SIGNAL AT A CONSTANTLY ATTENDED LOCATION. DEMOLITION NOTES 1. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2. PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS. 3. ERECT AND MAINTAIN DUST PROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES, AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT SURFACES. 4. IF DEMOLITION IS PERFORMED, IN EXCESS OF THAT REQUIRED, RESTORE AFFECTED AREAS AT NO COST TO THE OWNER. 5. REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. 6. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT, AND FIXTURES AS REQUIRED FOR NEW WORK. 7. REMOVE ABANDONED HVAC EQUIPMENT, INCLUDING DUCT WORK. 8. REMOVE ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING AND DEVICES, UNLESS OTHERWISE NOTED. 9. REMOVE EXISTING FLOOR FINISHES AND PREPARE SUB -FLOOR AS REQUIRED FOR NEW FLOOR FINISHES. REFLECTED CEILING NOTES 1. DESIGN SUSPENDED CEILING FRAMING SYSTEMS TO RESIST A LATERAL FORCE OF 20% OF THE WEIGHT OF THE CEILING ASSEMBLY AND ANY LOADS TRIBUTARY TO THE SYSTEM. USE A MINIMUM CEILING WEIGHT OF 5 POUNDS PER SQUARE FOOT TO DETERMINE THE LATERAL FORCE. 2. WHERE CEILING LOADS DO NOT EXCEED 5 POUNDS PER SQUARE FOOT AND WHERE PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM, THE FOLLOWING BRACING METHODS MAY BE EMPLOYED: 2.1 PROVIDE LATERAL SUPPORT BY FOUR WIRES OF MINIMUM No. 12 GAUGE SPLAYED IN FOUR DIRECTIONS 90 DEGREES APART, AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. PROVIDE THESE LATERAL SUPPORT POINTS 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' FROM EACH WALL. 2.2 ALLOW FOR LATERAL MOMENT OF THE SYSTEM. ATTACH MAIN RUNNERS AND CROSS RUNNERS AT TWO ADJACENT WALLS; MAINTAIN CLEARANCE BETWEEN THE WALL AND THE RUNNERS AT THE OTHER TWO WALLS. 2.3 PROVIDE VERTICAL SUPPORT AS REQUIRED IN BUILDING CODES. IN ADDITION, VERTICALLY SUPPORT ENDS OF RUNNERS WITHIN 8" OF DISCONTINUITIES SUCH AS MAY OCCUR WHERE THE CEILING IS INTERRUPTED BY A WALL. 2.4 SUPPORT LIGHT FIXTURES AND AIR DIFFUSERS DIRECTLY BY WIRES TO THE STRUCTURE ABOVE. 3. LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES. CENTER SPRINKLER HEADS, SPEAKERS, RECESSED FIXTURES, AND SIMILAR CEILING ELEMENTS IN ACOUSTICAL UNITS, UNLESS OTHERWISE NOTED. 4. FINISH HVAC DIFFUSERS, DRAPERY POCKETS, AND SPEAKER GRILLES TO MATCH ADJACENT FINISH, UNLESS OTHERWISE NOTED. POWER AND COMMUNICATION NOTES 1. PRIOR TO CORING SLAB, REVIEW LOCATIONS WITH ARCHITECT AND COORDINATE LOCATIONS WITH OWNER. 2. COORDINATE INSTALLATION OF TELECOMMUNICATIONS, DATA AND SECURITY SYSTEMS. 3. VERIFY EQUIPMENT SPECIFICATIONS, POWER AND INSTALLATION REQUIREMENTS WITH MANUFACTURER TO ENSURE PROPER FIT AND FUNCTION. 4. VERIFY MOUNTING REQUIREMENTS OF ELECTRICAL, TELEPHONE AND OTHER EQUIPMENT. 5. GANG ADJACENT LIGHT SWITCHES AND COVER WITH A SINGLE PLATE. 6. PROVIDE LIGHT SWITCHING IN CONFORMANCE WITH TITLE 24 REQUIREMENTS, FOR ROOMS OR AREAS GREATER THAN 100 SQUARE FEET PROVIDE DOUBLE SWITCHES WITH EACH SWITCH CONTROLLING 50% OF LAMPS PER FIXTURE. 7. MOUNT STANDARD WALL OUTLETS, SWITCHES AND THERMOSTATS AT HEIGHTS REQUIRED BY TITLE 24 AND ADA GUIDELINES, UNLESS OTHERWISE NOTED. WHEN THERMOSTATS AND LIGHT SWITCH OCCUR TOGETHER, INSTALL BOTH ALIGNED HORIZONTALLY WITH CENTER LINE AT +48" ABOVE FINISH FLOOR. 8. INDICATED DIMENSIONS ARE TO THE CENTER LINE OF OUTLET OR SWITCH, OR CLUSTER OF OUTLETS OR SWITCHES, UNLESS OTHERWISE NOTED. 9. INSTALL OUTLETS ON OPPOSITE SIDES OF PARTITIONS IN SEPARATE STUD CAVITIES. DO NOT INSTALL BACK- TO-BACK. 10. PROVIDE MATCHING COVER PLATES, RECEPTACLES AND RELATED ITEMS. PROVIDE ONE -PIECE TYPE GANG COVER PLATES, UNLESS OTHERWISE NOTED. 11. IDENTIFY DEDICATED OR ISOLATED GROUND ELECTRICAL OUTLETS WITH A RED DOT. FINISH NOTES 1. ENSURE SURFACES TO RECEIVE FINISHES ARE CLEAN, TRUE, AND FREE OF IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 2. REPAIR EXISTING SURFACES TO REMAIN AS REQUIRED FOR APPLICATION OF NEW FINISHES. 3. PROVIDE STRAIGHT, FLUSH RESILIENT BASE AT CARPETED AREAS, AND COVED, TOP SET RESILIENT BASE AT RESILIENT FLOORING, UNLESS OTHERWISE NOTED. 3s& ABBREVIATIONS A ACCES ACOUS ACT AFF AL ALT ANNUNC ANOD APPL ARCH AUTO AVG B BLDG BOLLD BD BLKG BRDLM BU C CAB CPT CEM CER CLG COATG COILG CONC CONSTR CONT CONTR COV CMU D DBL DEPT DES DET DF DIA DIFF DIM DISP DIV DN DR DSCON DWR E ELAST ELECT EMBED ENGR ENTR EQ EQUIP EXIST EXP JT EXPS EXT (E) F FAB FD FE FEC FIN FLDG FPLC FR FRMG FXD FXTR FLR FURN FWC FACP G GA GFRC GFRG GFRP GL GR GYP H HD HDWD HDWE HM HORIZ HVAC INFO INSTRUM INSUL INTLK INT INFILTR JAN ACCESSORY ACOUSTIC(AL) L ACOUSTICAL CEILING TILE LAV ABOVE FINISHED FLOOR LB ALUMINUM £ ALTERNATE ANNUNCIATOR ANODIZED APPLIANCE M ARCHITECT(URAL) AUTOMATIC AVERAGE AND ABBREVIATIONS (CONT.) KIT KITCHEN LT LVLG LVR BUILDING BOLLARD BOARD BLOCKING BROADLOOM BUILT UP CABINET CARPET CEMENT(ITIOUS) CERAMIC CEILING COATING COILING 0 CONCRETE CONSTRUCTION CONTINUOUS(ATION) CONTRACT(OR) COVER CONCRETE MASONRY UNIT OC MAX MFD MFR MECH MET MEMB MEZZ MIN MISC MLWK MOIST MOT MTD N NIC NO NTS (N) ORNA OVFL OVHD OPNG OPR DOUBLE DEPARTMENT DESIGN(ED) DETAIL DRINKING FOUNTAIN DIAMETER DIFFUSER DIMENSION DISPENSER DIVISION DOWN DOLLAR (US CURRENCY) DOOR DISCONNECT DRAWER ELASTOMERIC ELECTRICAL EMBEDD(ED)(ING) ENGINEER(ED) ENTRANCE EQUAL EQUIPMENT EXISTING EXPANSION JOINT EXPOSE(D) EXTERIOR EXISTING FABRICATION FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER AND CABINET FINISH FOLDING FIREPLACE FIRE RAT(ED)(ING) FRAMING FIXED FIXTURE FLOOR(ING) FURNITURE FABRIC WALL COVERING FIRE ALARM CONTROL PANEL GAUGE GLASS FIBER REINFORCED CONCRETE GLASS FIBER REINFORCED GYPSUM GLASS FIBER REINFORCED PLASTER GLASS GRAD(E)(ING) GYPSUM HEAD HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HEATING, VENTILATING AND AIR CONDITIONING INFORMATION INSTRUMENT(ATION) INSULATION INTERLOCK(ING) INTERIOR INFILTRATION JANITOR P PTN PEDTR PBD PNL POLYST PORT PREFIN PREFAB PLAM PLAS PLSTC PLYWD PRTECN R RDR RECES RECPT REF REFL REFR REQD RESIS REINF RESIL RFG RM RO S_ SCR SECUR SF SGL SHORG SIM SST STD STL STRFR STRUCT SURF SUSP SYS T THK TLT TRAF TRANS TRTD T &G TYP U UNDRLAY UTIL UNO V VEH VERT VIF W W/ WC WD WDW W/O WT WTRPRF LAVATORY POUND BRITISH POUND (CURRENCY) LIGHT LEVELING LOUVER MAXIMUM MANUFACTURED MANUFACTURER MECHANICAL METAL MEMBRANE MEZZANINE MINIMUM MISCELLANEOUS MILLWORK MOISTURE MOTOR(IZED) MOUNTED NOT IN CONTRACT NUMBER NOT TO SCALE NEW ORNAMENTAL OVERFLOW OVERHEAD OPENING(S) OPERABLE ON CENTER PARTITION PEDESTRIAN PARTICLE BOARD PANEL POLYSTYRENE PORTABLE PREFINISHED PREFABRICATED PLASTIC LAMINATE PLASTER PLASTIC PLYWOOD PROTECTION READER RECESSED RECEPTACLE REFER(ENCE) REFLECTED REFRIGERATOR REQUIRED RESIST(ANT)(IVE) REINFORCE(ING)(MENT) RESILIENT ROOFING ROOM ROUGH OPENING SCRIBE SECURITY SQUARE FEET SINGLE SHORING SIMILAR STAINLESS STEEL STANDARD STEEL STOREFRONT STRUCTURAL SURFACE SUSPENDED SYSTETM(S) THICK TOILET TRAFFIC TRANSPARENT TREATED TONGUE AND GROOVE TYPICAL UNDERLAYMENT UTILITY UNLESS NOTED OTHERWISE VEHICLE VERTICAL VERIFY IN FIELD WITH WATER CLOSET WOOD WINDOW WITHOUT WEIGHT WATERPROOFING REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2012 • City of Tukwila BUILDING DIVISION RECttvtu CITY OF TUKWILA NOV 2 7 2012 PERMIT CENTER CONSULTANT FIRM MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 1 CenturyLink GEO LOC ID (FLOOR FIRST BuLDINGNAn,UKWILA CYBER - INTERIOR UPGRADES STREET ADDRESS 6101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRP11ON ABBREVIATIONS & GENERAL NOTES STAMP ISSUED FOR CONSTRUCTION PERMIT REVISIONS CONSULTANT HALE NOTICE The information contained herein should not be disclosed to unauthorized persons. It is meant for use by authorized repro of CenbuyUnk No. DESCRIPTION DATE DRAWN BY AP DATE 10/12/12 CHEOCED BY BP CASE NUMBER JOB NO. 128296 REVISED BY BP /AP SCALE N.T.S. FIE NAME SHEET NO. A -001 P:1Project1128296_CenturyUnk .NDC Tukwila105 Deliverables101 Drawings108 }_ArchitecturelTukwIILA -001.dwg [36X241 Nov 21, 2012 - 10:40am Initials: ARNOLD.PALACIOS This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 JANITOR'S CLOSET MEN'S RESTROOM WOMEN'S RESTROOM ECEPTIOIV AREA j101I" 1- 1 1 I (E, I 1 1 I 1 I 1 1 1 1 1 L 1 1 I I I I I I I 1 I` /I 1 I I I 1 I 1 I /� 1 I -- 1-- --k- -- --- H- --1 - - + - -H - ,,/ i I 1 /. I 1 r I 1 1 1 1 1 1 1 I L 1 1- �' AECURITY 1 E 1 O 1 i LOBBY 1 1 1 1 104 1 1 1 _I_ ___. __I ___ _... + E.,1_ I__ _ __ _r__ F IL \ 1— II II —1 I II IIc —� —11 1.1 G --- HALLWAY 1 106 E �r - -I - -- -- T--- I--- l-- r- -I - - -r 1 _ I I 1 1 1 1 II I — r-- — . 1--- 1--- 1--- T--.�-- 1--- 1 - ---- 1 1 1 0 1 1 1 0 1 1 —I -- L - -��� J -- - -I -- H T 4'1 � a DEMOLITION REFLECTED CEILING PLAN SCALE: 1/4" =1'-0" JANITOR'S CLOSET 110 MEN'S RESTROOM 111 WOMEN'S RESTROOM 109 I L RECEPTION AREA 101 HALLWAY 1 106 HALLWAY 2 107 EQUIPMENT ROOM 108 r— ---- it - - - -- -- --K- -- - - - - -- 1 11 1 -I\ I II SECURITY LOBBY 104 CONFERENCE ROOM 105 2' DEMOLITION FLOOR PLAN SCALE: 1/4" =1' -0" GENERAL NOTES: 1. ALL TENANT WORK SHALL CONFORM WITH ALL APPLICABLE REGIONAL & LOCAL BUILDING, FIRE & ACCESSIBILITY CODES. 2. ALL NEW PARTITIONS WILL BE TYPE 3B & 3D, U.N.O. 3. PATCH & REPAIR ALL WALLS & (E) CONSTRUCTION DUE TO DEMOLITION AS NECESSARY TO ACCEPT NEW FINISHES. 4. REFER TO DESIGN BUILD ELECTRICAL DRAWINGS FOR POWER & CIRCUITING REQUIREMENTS ONLY. LOCATIONS SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FOR LOCATION ONLY. IF DISCREPANCIES OCCUR, CONFIRM WITH ARCHITECT BEFORE INSTAWNG. 5. EXPOSED OUTLETS, STATS, DEVICES & HARDWARE, SHALL MATCH EXISTING IN COLOR & TYPE, U.N.O. 6. FURNITURE & EQUIPMENT ARE SHOWN FOR REFERENCE ONLY. - N.I.C. 7. ANY SECURITY DEVICES REMOVED MUST BE PRESENTED TO OWNER FOR FIRST RIGHT OF REFUSAL. DEMO RCP KEYED NOTES: 1. (E) ACT PORTION TO BE REMOVED AS REQUIRED 2. (E) HEADER TO BE REMOVED 3. (E) MECHANICAL DEVICE TO BE REMOVED /RELOCATED — PER MECHANICAL DRAWINGS 4. (E) MECHANICAL DEVICE TO REMAIN - PER MECHANICAL DRAWINGS 5. (E) ELECTRICAL DEVICE TO BE REMOVED/RELOCATED - PER ELECTRICAL DRAWINGS 6. (E) ELECTRICAL DEVICE TO REMAIN — PER ELECTRICAL DRAWINGS DEMO FLOOR PLAN KEYED NOTES: 1. (E) CASEWORK TO BE REMOVED 2. (E) DOUBLE DOORS TO BE REUSED - CHANGE SWING DIRECTION 3. (E) DOUBLE DOORS TO BE REMOVED 4. (E) ELECTRICAL DEVICE TO BE REMOVED/RELOCATED - PER ELECTRICAL DRAWINGS 5. (E) ELECTRICAL DEVICE TO REMAIN — PER ELECTRICAL DRAWINGS 6. (E) PARTITION WALL TO BE REMOVED 7. (E) EQUIPMENT TO BE REMOVED/RELOCATED 8. (E) REFRIGERATOR TO BE REUSED 351 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 05 2012 City of Tukwila BUILDING DIVISION KEY PLAN SCALE: N.T.S. RLCtivEu CITY OF TUKsitin A NOV 2 7 2012 PERMIT CENTER MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279-1234 STAMP CONSULTANT FM CenturyLink GEO LOC 13 FLOOR FIRST BU TUKWILA CYBER - INTERIOR UPGRADES sTREETADDRESS 6101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRPTIDN DEMOLITION FLOOR & RCP PLANS ISSUED FOR CONSTRUCTION PERMIT REVISIONS CONSULTANT NAME NOTICE The informatbn contained herein should not be disclosed to unauthorized persons. his meant for use by authorized represenlalves of CenhsyLNK No. DESCRIPTION DATE DRAWN BY AP DATE 10/ —/12 CHECKED BY BP CASE NUMBER JOB NO. 128296 FILE NAME REVISED BY BP /AP SCALE 1/4"=t-0" SHEET NO. A -101 P:\ Pro] ect1128296 _CenturyLinIODC_Tukwlla105 Deliverabies101 Drawings108_A Architecture1Tukwilaik- 101.dwg [36X24] Nov 21, 2012 - 10:44am Initials: ARNOLD.PALACIOS This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 JANITOR'S CLOSET MEN'S RESTROOM WOMEN'S RESTROOM EIQUIPMEMT ROOM 2' JANITOR'S CLOSET 110 NEW REFLECTED CEILING PLAN SCALE: 1/4" =1' -0" tiis MEN'S RESTROOM 111 WOMEN'S RESTROOM 109 8'- 31/16" BYPASS BREAK ROOM 112 T-8 5/8' CLR. SECURITY LOBBY 104 HALLWAY 1 106 CLR. HALLWAY 2 107 o unk° 7'-8 5/8" 12' TOUCH DOWN 108 CONFERENCE ROOM 2' NEW FLOOR PLAN SCALE: 1/4" =1' -0" GENERAL NOTES: 1. ALL TENANT WORK SHALL CONFORM WITH ALL APPLICABLE REGIONAL & LOCAL BUILDING, FIRE & ACCESSIBILITY CODES. 2. ALL NEW PARTITIONS WILL BE TYPE 3B & 3D, U.N.O. 3. PATCH & REPAIR ALL WALLS & (E) CONSTRUCTION DUE TO DEMOLITION AS NECESSARY TO ACCEPT NEW FINISHES. WHERE NEW FINISHES ARE NOT SPECIFICALLY CALLED OUT, PROVIDE FINISHES TO MATCH ADJACENT. 4. REFER TO DESIGN BUILD ELECTRICAL DRAWINGS FOR POWER & CIRCUITING REQUIREMENTS ONLY. LOCATIONS SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FOR LOCATION ONLY. IF DISCREPANCIES OCCUR, CONFIRM WITH ARCHITECT BEFORE INSTALLING. 5. EXPOSED OUTLETS, STATS, DEVICES & HARDWARE, SHALL MATCH EXISTING IN COLOR & TYPE, U.N.O. 6. FURNITURE & EQUIPMENT ARE SHOWN FOR REFERENCE ONLY. - N.I.C. NEW RCP KEYED NOTES: 1. NEW ACOUSTICAL CEILING TILE TO MATCH EXISTING CONDITIONS & HEIGHT - V.I.F. 2. NEW /RELOCATED MECHANICAL DEVICE - PER MECHANICAL DRAWINGS 3. (E) MECHANICAL DEVICE TO REMAIN - PER MECHANICAL DRAWINGS 4. NEW /RELOCATED ELECTRICAL DEVICE - PER ELECTRICAL DRAWINGS 5. (E) ELECTRICAL DEVICE TO REMAIN - PER ELECTRICAL DRAWINGS 6. NEW 2'X2' ACOUSTICAL CEILING TILE AT 9' -0" A.F.F. - SEE SCHEDULES 7. ELECTRONIC SCREEN NEW FLOOR PLAN KEYED NOTES: 1. FULL HEIGHT TO STRUCTURE BULLET PROOF PARTITION WALL 2. PARTIAL HEIGHT (6" OVER CEILING) PARTITION WALL 3. CHECK -IN COUNTER 4. (E) DOUBLE DOORS IN NEW OUTWARD SWING POSITION 5. NEW CASEWORK - TOP & BOTTOM KITCHEN CABINETS 6. (E) KEVLAR REINFORCED WALL TO REMAIN 7. NEW /RELOCATED ELECTRICAL DEVICE - PER ELECTRICAL DRAWINGS 8. (E) ELECTRICAL DEVICE TO REMAIN - PER ELECTRICAL DRAWINGS 9. PATCH & REPAIR WALL CORNER - SEE SHEET A -103 FOR PAINT COLOR & FINISH 10. BUILT -IN TOUCHDOWN CASEWORK COUNTER 11. UNDER COUNTER DISH WASHER - N.I.C. 12. REUSED REFRIGERATOR 13. VENDING MACHINES - N.I.C. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2012 City of Tukwila BUILDING DIVISION MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 STAMP CONSULTANT FIRM CenturyLink GEO LOC D (44) KEY PLAN SCALE: N.T.S. RECtivEU CITY OF TUK1M1.A NOV 2 7 2012 PERMIT CENTER FLOOR FIRST BUID"G NAMFTUKWILA CYBER - INTERIOR UPGRADES STREET ADDRESS 6101 SOUTH 180TH. STREET CRY, STATE TUKWILA, WA. 98188 DESCRIPTION NEW FLOOR & RCP PLANS ISSUED FOR CONSTRUCTION PERMIT REVISIONS DESCRIPTION CONSULTANT NAME NOTICE The information contained herein should not be dlsdosed a unauthorized persons. It is meant for use by autlarked representatives of CenturyLhdc. DATE DRAWN BY DATE CHECKED BY REVISED BY SCALE AP 10/ —/12 BP BP /AP 114 " =1' -0" CASE NUMBER JOB NO. 128296 FILE NAME SHEET NO. A -102 This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 JANITORS CLOSET 110 MEN'S RESTROOM 111 WOMEN'S RESTROOM 109 BYPASS 102 BREAK ROOM 112 SECURITY LOBBY 104 HALLWAY 1 106 ... HALLWAY 2 .1111•MNI 107 TOUCH DOWN 108 1 11 1 H 1 . I 2' ENLARGED FINISH FLOOR PLAN SCALE: 3/8" GENERAL NOTES: 1. ALL TENANT WORK SHALL CONFORM WITH ALL APPLICABLE REGIONAL & LOCAL BUILDING, FIRE & ACCESSIBILITY CODES. 2. ALL NEW PARTITIONS WILL BE TYPE 3B & 3D, U.N.O. 3. PATCH & REPAIR ALL WALLS & (E) CONSTRUCTION DUE TO DEMOLITION AS NECESSARY TO ACCEPT NEW FINISHES. WHERE NEW FINISHES ARE NOT SPECIFICALLY CALLED OUT, PROVIDE FINISHES TO MATCH ADJACENT. 4. REFER TO DESIGN BUILD ELECTRICAL DRAWINGS FOR POWER & CIRCUITING REQUIREMENTS ONLY. LOCATIONS SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FOR LOCATION ONLY. IF DISCREPANCIES OCCUR, CONFIRM WITH ARCHITECT BEFORE INSTALLING. 5. EXPOSED OUTLETS, STATS, DEVICES & HARDWARE, SHALL MATCH EXISTING IN COLOR & TYPE, U.N.O. 6. FURNITURE & EQUIPMENT ARE SHOWN FOR REFERENCE ONLY. - N.I.C. FINISH FLOOR PLAN KEYED NOTES: 1. 15" CLOCK 2. 30" CLOCK 3. 30" CANVAS GRAPHICS - N.I.C. 4. TRACERY SCULPTURE - N.I.C. 5. 6' SAWS SIGN 6. 12' SAWIS SIGN 7. 8 PC. GRID - N.I.C. 8. 16 PC. GRID - N.I.C. 9. 42" CANVAS PRINT 10. PT2 - STONE HEARTH (BENJAMIN MOORE 984) SECONDARY WALL COLOR 11. PT3 - RUBY RED (BENJAMIN MOORE 2001-10) ACCENT WALL COLOR 12. NEW CARPET 13. NEW V.C.T. 14. SERVER TABLE - N.I.C. 15. PROJECTOR - N.I.C. 16. ELECTRONIC SCREEN 17. COALESSE SIDEWALK LOUGE/MOBILE CHAIR - N.I.C. 18. CHAIRS & TABLES - N.I.C. 19. VENDING MACHINES - N.I.C. 20. REUSED REFRIGERATOR 21. KITCHEN SINK 22. KITCHEN CABINETRY 23. TV W/ MONITOR SHROUD - N.I.C. 24. COALESSE CIRCA TABLE - N.I.C. 25. UNDER COUNTER DISH WASHER - N.I.C. 26. RULES SIGN - N.I.C. ,7D bP3S REVIEWED FOR CODE COMPLIANCE APPROVED DEC 05 2012 City of Tukwila BUILDING DIVISION KEY PLAN SCALE: N.T.S. RECtivto CITY OF TUKWIL A NOV 2 7 2012 PERMIT CENTER CONSULTANT FIRM BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE 800 PHOENIX, ARIZONA 85012 (602) 279-1234 1 k CenturyLink GEO LOC 11) FLOOR FIRST BUILDING NAI%KWILA CYBER - INTERIOR UPGRADES STREET ADDRESS 6101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRIPTION ENLARGED FINISH FLOOR PLAN STAMP ISSUED FOR CONSTRUCTION PERMIT REVISIONS CONSULTANT NAME NOTICE The Information contained herein should not be dbdosed lo unauthodzed persons. It b meant for use by aulhorlzed rsvresentatIves of CenturyUnt No. DESCRIPTION DATE DRAWN BY AP DATE 10/-/12 CHECKED BY BP CASE NUMBER JOB NO. 128296 REVISED BY BP/AP 3/8" =11-0" FLE NAME SHEET NO. A-103 Initials: ARNOLD,PALACIOS This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission CO 2012 UL752 LEVEL 3 BALLISTIC FIBERGLASS PANEL, SECURE TO METAL STUDS 16 GA. TOP TRACK LEVEL III BULLET RESISTANT LP1250 GLAZING v STAINLESS STEEL ANGLE 5/8" GYP. BOARD - BOTH SIDES CONT. SEALANT BOTH SIDES OF FRAME STAINLESS STEEL CAP LINED W/ LEVEL III FIBERGLASS STAINLESS STEEL FRAME LINED WI LEVEL III FIBERGLASS 0 co W LL STAINLESS STEEL REMOVABLE STOP INSTALLED W/ #10 - 2" FHP STAINLESS STEEL COUNTERTOP TO BE SELECTED, DESIGNED & SPECIFIED BY OWNER EN, CONT. SEALANT BOTH SIDES OF FRAME UL752 LEVEL 3 BALLISTIC FIBERGLASS PANEL, SECURE TO METAL STUDS RECESSED CURRENCY DEAL TRAY J DRYWALL BEAD METAL STUD 5/8" GYP. BOARD - BOTH SIDES BALLISTIC TRANSACTION WINDOW SECTION SCALE: 1 1/2" =1' -0" ATTACH BRACE TO DECK ABOVE W /(2) HILTI S -MD10- 16X1 -1/4 HWH# SELF - DRILLING SCREWS © EACH BRACE LOCATION STUD TRACK, TYP. N LAY -IN ACOUSTICAL CEILING PER REFLECTED CEILING PLANS POWER DRIVEN FASTENERS @ 24" O.C. PER ICBO #2388. USE HILTI FLATHEAD TRACK NAIL #X -DE2OT W /MIN. 5/8" EMBEDMENT 25 GA. WALL BRACING @ 48" O.C. - ATTACH TO STUD TRACK W /(3) HILTI 'HWH" SHEET METAL SCREWS @ EA. BRACE LOCATION GYP. BD. OVER METAL STUDS PER WALL TYPES WALL BASE - PER SCHEDULE FLOOR COVERING - PER SCHEDULE EXIST. CONC. LAB CONTINUOUS "3M" SEALANT, TYP. 1/2 "X CONTINUOUS FIRE - RETARDANT PLYWOOD SHEATHING - DUCT TAPE ALL JOINTS CONTINUOUS "3M" SEALANT, TYP. TYPICAL METAL STUD 1 112" =l' -0" CEILING - AS OCCURS UNDERSIDE OF DECK ABOVE TOP SAFE SIDE 3 5/8" METAL STUDS AT 16" O.C. PLAN FLOOR SLAB - AS OCCURS NOTE: GRYFFOLYN SHEETING FULL LENGTH OF IIUST PARTITION - PROVIDED BY CONTRACTOR 4" WIDE BATTEN STRIP AT EA. BULLET PROOF PANEL SEAM 25 GA. METAL STUDS, AS SPECIFIED BULLET PROOF PANEL DRYWALVMILLWORK SEAM TO BE PLACED OFFSET FROM BULLET PROOF PANEL METAL STUDS BULLET PROOF PANEL 0 0 0 0 ISOMETRIC VIEW DRYWALL/MILLWORK, AS SPECIFIED DRYWALL AS SPECIFIED PI2"1' 2" I DRYWALL/MILLWORK SEAM TO BE PLACED OFFSET FROM BULLET PROOF PANEL PLAN VIEW BULLET RESISTANT FIBERGLASS INSTAL. N.T.S. SECTION VIEW UL LISTED BULLET RESISTANT FIBERGLASS PANEL BATTEN STRIP (CUT FROM FIBERGLASS FULL SHEET) 25 GA. METAL STUDS (BY OTHERS) JOINTS BETWEEN FIBERGLASS PANELS MUST BE KEPT AS TIGHT AS POSSIBLE \,, / _ \ G �,r \ ACCEPTABLE / \ s UNACCEPTABLE / �-- 24" O.C. INTO WALL PLATE 18" O.C. INTO WALL STRUCTURE NOTE: (BULLET RESISTANT PANEL SHOULD BE INSTALLED WITH FULL LOAD RESTING SECURELY AGAINST SLAB. ANCHOR TO WALL PLATE AND WALL STRUCTURE AS SHOWN.) BULLET RESISTANT FIBERGLASS INSTAL. N.T.S. TEMPORARY DUST PATITION 3" = 1'-0" NOT USED N.T.S. NOT USED N.T.S. BASE THREAT SIDE FIRE (3D4,3D5) OR ACOUSTICAL (3D3) SEALANT BOTH SIDES PARTITION TO EXTEND TO UNDERSIDE OF STRUCTURE ABOVE - PARTITIONS NOT TO EXCEED 16' -0" MAX. (3D2, 3D3, 3D4, 3D5) -- METAL RUNNER CHANNEL 5/8" 3 5/8" 1/ 5/8" 5 3/8" SCHEDULED CEILING SYSTEM UL752 LEVEL 3 BALLISTIC FIBERGLASS PANEL, SECURE TO METAL STUDS 3 5/8" 25 GA. @ 16" O.C. METAL STUD 2 1/2" MIN. BATT INSULATION (3D3, 3D4) 5/8" GYP. BOARD METAL RUNNER CHANNEL FIRE (3D4,3D5) OR ACOUSTICAL (3D3) SEALANT BOTH SIDES SCHEDULED FINISHED FLOOR 3D1: INSULATION, FULL HEIGHT (6" OVER CEILING) 3D2: NO INSULATION, FULL HEIGHT (SMOKE PARTITION) 3D3: INSULATION, FULL HEIGHT - BOTTOM OF DECK (STC 45) 3D4: INSULATION, TYPE "X" GYP. BD, FULL HEIGHT, (STC 45,1 HR RATED) 3D5: NO INSULATION, TYPE "X" GYP. BD, FULL HEIGHT (1 HR RATED) 3D6: NO INSULATION, FULL HEIGHT STC TEST NO:NGC 2386 UL TEST NO: U465 1- 112 "X3 "X16 GA. CHANNEL CLIP ANGLE 1/4" LESS THAN STUD WIDTH, TYP. - ATTACH AT EVERY STUD W/ (4) 5/8" #S -12 SCREWS OR 3/4" WELDS IN (3) PLACES 3/4" 16 GA. COLD - ROLLED CHANNEL - LOCATE AT 4' -0" O.C. HORIZONTALLY, OR AS REQUIRED BY LOCAL CODE METAL STUD FRAMING, TYP. SEE PARTITION DETAILS FOR SIZE, GAUGE & SPACING PARTITION TYPE 3D - LEVEL 3 3" =1' -0" PROVIDE CLIP ANGLE(S) + 5' -0" A.F.F. AT WALLS 10' -0" HIGH OR LESS, AND EVERY 4' -0" AT WALLS GREATER THAN 10' -0" OR AS REQUIRED BY LOCAL CODES TYPICAL BRIDGING DETAIL 6" =1' -0" NOT USED N.T.S. UNDERSIDE OF DECK ABOVE TOP PLAN BASE FIRE (3B4,3B5) OR ACOUSTICAL (3B3) SEALANT BOTH SIDES PARTITION TO EXTEND TO UNDERSIDE OF STRUCTURE ABOVE - PARTITIONS NOT TO EXCEED 16' -0" MAX. (3B2, 3B3, 3B4, 3B5) METAL RUNNER CHANNEL SCHEDULED CEILING SYSTEM 3 5/8" 25 GA. @ 16" O.C. METAL STUD 21/2" MIN. BATT INSULATION (3B3, 3B4) 5/8" GYP. BOARD METAL RUNNER CHANNEL FIRE (3B4,3B5) OR ACOUSTICAL (3B3) SEALANT BOTH SIDES 3B1: 3B2: 3B3: 3B4: 3B5: 3B6: 5/8" It, 3 5/8" , 5/8" 4 7/8" SCHEDULED FINISHED FLOOR NO INSULATION, NOT FULL HEIGHT (6" OVER CEILING) NO INSULATION, FULL HEIGHT (SMOKE PARTITION) INSULATION, FULL HEIGHT (STC 45) INSULATION, TYPE "X" GYP. BD, FULL HEIGHT, (STC 45,1 HR RATED) NO INSULATION, TYPE "X" GYP. BD, FULL HEIGHT (1 HR RATED) NO INSULATION, FULL HEIGHT STC TEST NO:NGC 2386 UL TEST NO: U465 bix--3v0 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2012 City of Tukwila BUILDING DIVISION PARTITION TYPE 3B 3" =1' -0" RECEivED CITY OF TUKYt I!_A NOV 2 /2012 PERMIT CENTER CONSIA_TANT FIRM MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279-1234 CenturyLink GEOLOCD FLOOR FIRST BUILDING TUKWILA CYBER - INTERIOR UPGRADES STREET ADDRESS 6101 SOUTH 180TH. STREET CRY, STATE TUKWILA, WA. 98188 DESCRIPTION PARTITION TYPES & DETAILS STAMP ISSUED FOR CONSTRUCTION PERMIT No. REVISIONS DESCRITDN DATE CITY COMMENTS 11/19/2012 CONSULTANT NAME NOTICE The Information contained her& shorld not be dIsdosed b unauthorized persons. It M meant for use by aulrodzed rePAIGENIMVOS of CenturyUnt DRAWN BY DATE CHECKED BY REVISED BY SCALE AP 10/12/12 BP CASE NUMBER JOB NO. 128296 FILE NAME BP /AP INDICATED SHEET NO. A -501 P:1 Project1128296 _CenturyLink_NDC_Tukwila105 Deliverables101 Drawings1 08 J{JArchitecturelTukwilaA- 501.dwg [36X24] Nov 21, 2012 - 10:46am Initials: ARNOLD.PALACIOS This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 BYPASS 11' -11" +/- V.LF. 1 4' -2 3/8" +/- V.I.F. 1' -81/8" )' -0 1/2 ", 1• M BALLISTIC TRANSACTION WINDOW BASE - PER SCHEDULE TRANSACTION WINDOW ELEVATION 1/2" =1' -0" NOT USED N.T.S. NOT USED N.T.S. C.)) ADJUSTABLE FIX CEILING STRUCT URE HI RE 4'-0 METAL CEILING CHANNEL. FRAME AROUND FIXTURE i( AS REQUIRED - CEILING TRIM GER TO BE WIRED TO O.C. c5 12 GA HANGER WIRE TO STRUCT. ABOVE EA. CORNER OF FIXTURE 55 JUNCTION BOX RECESSED FLUORESCENT FIXTURE 3" =1' -0" NOT USED N.T.S. 12 GA. HANGER WIRE TYP. 4' -0" O.C. (3 TIGHT WRAPS) MAIN BEAM 4' -0" O.C. COMPRESSION POST CROSS TEES 2' -0" O.C. 12 GA. BRACE WIRES BRACING NOTES: 1. VERTICAL POSTS MAY NOT BE REQUIRED IN SOME CITIES AND NOT ENFORCED IN ALL SEISMIC ZONES. 2. BRACING WIRES TO BE ATTACHED A MAXIMUM OF 45° TO THE PLANE OF THE CEILING AND PARALLEL TO THE COMPONENTS AT THE BRACING POINT. BRACE WIRES TO BE TAUT AND TIED BOTH ENDS WITH THREE TIGHT WRAPS. CONNECTION DEVICE (100 LB. CAPACITY MIN.) PINNED TO CEILING STRUCTURE & BOLTED TO OMPRESSION STRUT COMPRESSION STRUT DETAIL N.T.S. BOTTOM OF STRUCTURE ABOVE VERTIC COMPRESSION STRUT MA i FROM .055 STEEL TUBIN ACOUSTICAL CEILING TILE TYPIC 712 GA. VE �AL CEILING GER CLIP ON END OF VERTICAL BRACE FOR SNAPPING & LOCKING ON MAIN RUNNER NOTES: MAX. MAX. 1. AREA OF CEILING SUPPORTED NOT TO EXCEED 1,000 SQ.FT. 2. DIAGONAL SPLAY WIRE MAX. BRACE SPACING NOT TO EXCEED 12' -0" BOTH DIRECTIONS 3. VERTICAL HANGER MAX. SPACING NOT TO EXCEED 4' -0" O.C. BOTH DIRECTIONS 4. FIRST BRACING POINT WITHIN 6 %0" OF EACH WALL 5. BRACE POINT ON MAIN RUNNER NOT TO EXCEED 2" DISTANCE FROM CROSS RUNNER CEILING MAIN UNNER 12 GA. BRACE WIRES AT 45° IN 4 DIRECTIONS - WIRES TIED TO GRID CEILING CROSS TIE SEISMIC BRACING @ ACOUSTICAL CEILING 3" =1' -0" NOTE: 1. 11E ADJACENT WALLS TO CEILING MAIN & CROSS RUNNER. 2. INSTALL CEILING GRID USING No.12 GA. SPLAY WIRE HANGERS AT 45° W/ RUNNER, 90° TO EA. OTHER (4 WIRES) BEGINNING 6%0" FROM STARTING POINT OF GRID & TILE LAYOUT & IN BOTH DIRECTIONS AT 12-0" THEREAFTER. 3. USE OF POP RIVETS IS NOT ALLOWED IN SEISMIC DESIGN CATEGORY D. 6' MAX. 12' CLG. COMPRESSION STRUT SCHEDULED CLG. SYSTEM SECTION SEISMIC BRACING DETAIL REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2012 • City of Tukwila BUILDING DIVISION 3/32" = 1' -0" RECtWvEi) CITY OF TUKV t.A NOV 2 / 2012 PERMIT CENTER CONSULTANT FIRM MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279-1234 1 ®CenturyLink GEO LOCI) FLOOR FIRST BUILDING TUKWILA CYBER - INTERIOR UPGRADES STREET ADDRESS 6101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRIPTION ARCHITECTURAL DETAILS STAMP ISSUED FOR CONSTRUCTION PERMIT REVISIONS CONSULTANT NAME NOTICE The info"natbn contained herein should not be disdosed b unaWiafzed persons.It is meant for use by aulhortrad represerlatives of Cenh J *. Na DESCRIPTION DATE DRAWN BY AP DATE 10/12/12 CHECKED BY BP CASE NUMBER JOB NO. 128296 REVISED BY BP /AP SCALE INDICATED FLE NAME SHEET NO. A -502 P:1 Project1128296_ CenturyLink _NDC_Tukwila105_Deliverables101 Drawings \08 1 Architecturegukwila_A,502.dwg [36X24] Nov 21, 2012 - 10:47am Initials: ARNOLD.PALACIOS NOT USED N.T.S. THREAT SIDE UL752 LEVEL 3 BALLISTIC FIBERGLASS PANEL, SECURE TO METAL STUDS UL USTED BULLET RESISTANT COMPOSITES UL USTED BULLET RESISTANT GLAZING s 41/4 "TO8' WALL J NOT USED N.T.S. SAFE SIDE 5/8" GYPSUM BOARD ADJUSTMENT SCREW 16 GA. PRIME PAINTED STEEL FRAME (STAINLESS STEEL OPTIONAL) HEAD @ CHECK -IN WINDOW 5 /8" GYPSUM BOARD CV SAFE SIDE SCALE: 3" =1' -0" 16 GA. PRIME PAINTED STEEL FRAME (STAINLESS STEEL OPTIONAL) REMOVABLE STOP 1" X 1" UL LISTED BULLET RESISTANT GLAZING L752 LEVEL 3 BALLISTIC rIBERGLASS PANEL, SECURE TO METAL STUDS SEALANT BOTH SIDES THREAT SIDE 5/8" GYPSUM BOARD SEALANT - BOTH SIDES 1/2" HOLLOW METAL FRAME PER SCHEDULE 5/8' GYPSUM BOARD 3 5/8' METAL STUD HEADER METAL CUP HOLLOW METAL DOOR - PER SCHEDULE H.M. DOOR HEAD @ FRAMED WALL METAL STUDS AT 16" O.C. - PROVIDE DOUBLE STUDS AT ALL JAMBS SCALE: 3" =1' -0" DOOR SWING HOLLOW METAL DOOR - PER SCHEDULE 5/8" GYPSUM BOARD SEALANT BOTH SIDES 2" 3 5/8" METAL STUD TRACK AT SILL CONDITION HOLLOW METAL FRAME - PER SCHEDULE H.M. DOOR JAMB @ FRAMED WALL 5/8" GYPSUM BOARD SEALANT - BOTH SIDES SAFE SIDE SCALE: 3" =1' -0" BALLISTIC PACKED STEEL / FRAME - PER SCHEDULE UL752 LEVEL 3 BALLISTIC FIBERGLASS PANEL, SECURE TO METAL STUDS 16 GA. TOP TRACK THREAT SIDE BULLET RESISTANT DOOR - PER SCHEDULE BULLET RESISTANT DOOR HEAD DETAIL A SCALE: 3" =1' -0" UL752 LEVEL 3 BALLISTIC FIBERGLASS PANEL, SECURE TO METAL STUDS THREAT SIDE Z Z ANCHORS AS REQUIRED (BY OTHERS) UL LISTED BULLET RESISTANT COMPOSITES JAMB @ CHECK -IN WINDOW SCALE: 3" =1' -0" 5/8" GYPSUM BOARD SEALANT BOTH SIDES DOOR SWING 7 BULLET RESISTANT DOOR - PER SCHEDULE 2" SAFE SIDE METAL STUDS AT 16" O.C. - PROVIDE DOUBLE STUDS AT ALL JAMBS BALLISTIC PACKED STEEL FRAME - PER SCHEDULE BULLET RESISTANT DOOR JAMB DETAIL SCALE: 3" =1' -0" FINISH SCHEDULE ROOM FLOOR WALL CEILING NOTES BASE NORTH - EAST SOUTH WEST NO. NAME MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL HEIGHT 101 S.O.C. CPT RB EXIST. PT1 ., PT1 EXIST. EXISTJACT MATCH EXIST, REPAINT EXISTING PAINTED WALLS 102 BYPASS CPT RB PT1 , PT1 PT1 EXIST. EXISTJACT MATCH EXIST. REPAINT EXISTING PAINTED WALLS 103 MAN TRAP CPT RB PT1 PT1 PT1 PT1 EXISTJACT 9' -0" REPAINT EXISTING PAINTED WALLS 104 SECURITY LOBBY CPT RB PT1 PT3 PT2 PT1 EXISTJACT MATCH EXIST, REPAINT EXISTING PAINTED WALLS 105 CONFERENCE ROOM CPT RB EXIST. PT2 EXIST. EXIST. EXISTJACT EXIST. REPAINT EXISITNG PAINTED WALLS 106 HALLWAY 1 CPT RB PT1 N/A PT2 PT1 EXISTJACT MATCH EXIST REPAINT EXISITNG PAINTED WALLS 107 HALLWAY 2 CPT RB PT1 PT1 PT1 PT1 ACT MATCH EXIST, REPAINT EXISITNG PAINTED WALLS 108 TOUCH DOWN AREA ROOM CPT EXIST. RB EXIST. N/A EXIST. PT2 EXIST. PT1 EXIST. PT1 EXIST. _ ACT EXIST. MATCH EXIST EXIST. REPAINT EXISTING PAINTED WALLS - 109 WOMEN'S RESTROOM 110 JANITORS CLOSET EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. - 111 MEN'S RESTROOM EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. - 112 BREAK ROOM VCT RB PT1 PT1 PT1 PT1 EXIST. EXIST. REPAINT EXISTING PAINTED WALLS DOOR SCHEDULE DOOR NO. DOOR FRAME DOOR TYPE SIZE WIDTH A ( D102 D103A D103B ( D105 C B B 3' -0" 3' -0" 3' -0" 3' -0" HEIGHT 7' -O" 8' -0" 8' -0" 8' -0" THK. 3 /4" 1 3/4" 1 3/4" 1 3/4" DOOR MATERIAL/ DOOR FINISH FIRE RTG STEEL STEEL �� -- - - - STEEL STEEL FRAME MATERIAL/ FRAME FINISH STEEL STEEL STEEL STEEL TYPE HARDWARE GROUP NO. NOTES 4 3 2 2 1 EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXISTING DOOR / NEW OUTWARD SWING POSITION (BID 1 OPTION) ROOM FINISH NOTES: UNLESS NOTED OTHERWISE HEREIN, PROVIDE FINISH, COLOR AND SHEEN AS FOLLOWS: CEILINGS WALLS FIRE PROTECTION EQUIPMENT MECH, ELECTRICAL FERROUS METAL ITEMS UNLESS REQUIRED TO BE COLOR CODED TOP AND BOTTOM EDGES OF DOORS PATCH AND REPAIR WORK PAINT SCHEDULE: EXTERIOR HOLLOW METAL DOORS, FRAMES INTERIOR HOLLOW METAL DOORS, FRAMES INTERIOR PLASTER/GYP. BOARD PT1 PT2 PT3 EGGSHELL EGGSHELL GLOSS RED MATCH COLOR OF ADJACENT WALL SURFACE SAME AS SPECIFIED FOR FACE OF LEAF MATCH EXISTING ADJACENT SURFACE MATCH EXISTING MATCH EXISTING MATCH EXISTING DOVE WING (BENJAMIN MOORE OC-18) PRIMARY WALL COLOR STONE HEARTH (BENJAMIN MOORE 984) SECONDARY WALL COLOR RUBY RED (BENJAMIN MOORE 2001 -10) ACCENT WALL COLOR SCHEDULE ABBREVIATIONS: HM STR GB CPT NO WORK/MATERIAL SCHED. HOLLOW METAL STRUCTURE GYPSUM BOARD CARPET TILE HARDWARE LIST: HEAVY DUTY HINGES ELECTRIC HINGES ELECTRIC LOCKSET DELAYED EGRESS ELECT. PANIC CLOSER DOME FLOOR STOP POWER SUPPLY KICKPLATE POWER SUPPLY VCT PT EXIST RB ACT ' COORDINATE ALL SECURITY REQUIREMENTS W/ STANLEY. VERIFY ALL AND WORK TOGETHER BEFORE INSTALLING. DOOR AND FRAME NOTES: VINYL COMPOSITE TILE PAINT EXISTING CONSTRUCTION RESILIENT BASE ACOUSTICAL CEILING TILE US26 FINISH U.O.N. MCKINNEY T2714 - 4.5' X 4.5" X NPR MCKINNEY T2714 E - 4.5' X 4.5' X QC SCHLARGE L9080PEU -RX -07A VON DUPRIN CHEXIT E- CX9875L X 07-F LCN 4010 SERIES IVES FS436 VON DUPRIN AS REQD. FOR HARDWARE ROCKWOOD MANF. K1050 10'H X 34'W VON DUPRIN AS REQD. FOR HARDWARE HARDWARE & EQUIPMENT HAVE NECESSARY POWER/COMM 1. 4' -0" DOOR WIDTHS REQUIRE 5" HINGES. 2. GENERAL CONTRACTOR TO PROVIDE CONSTRUCTION CORES, TYP. 3. FRAMES FULLY WELDED AT S.O.C. & MAN TRAP r i r 1 5/8" GYPSUM BOARD SEALANT BOTH SIDES 4" THREAT SIDE SAFE SIDE UL752 LEVEL 3 BALLISTIC FIBERGLASS PANEL, SECURE TO METAL STUDS DOOR HINGE - PER SCHEDULE BULLET RESISTANT DOPR - PER SCHEDULE I METAL STUDS AT 16' O.C. - PROVIDE DOUBLE STUDS AT ALL JAMBS BALLISTIC PACKED STEEL FRAME - PER SCHEDULE BULLET RESISTANT DOOR JAMB DETAIL SCALE: 3" =1' -0" HARDWARE GROUP: GROUP #1 BULLETGUARD SINGLE DELAYED EGRESS FULLY COMPLIANT W/ SECTION 1008.1.9.7 FOR DELAYED EGRESS. INCLUDES THE FOLLOWING SIGNAGE, "PUSH UNTIL DOOR ALARM SOUNDS, DOOR CAN BE OPENED IN 15 SECONDS" 1 1/2 PR HEAVY DUTY HINGES 1 POWER SUPPLY 1 DELAYED EGRESS ELECTRIC PANIC 3 SILENCERS 1 DOME FLOOR STOP 1 CLOSER 1 KICKPLATE 1 DOOR CONTACT (BY SECURITY) 1 PUSH BUTTON DOOR RELEASE (BY SECURITY), LOCATE BUTTON IN S.O.C. 1 BIO READER (BY SECURITY) 2 CARD READER (BY SECURITY) GROUP #2 BULLETGUARD SINGLE, INSIDE LEVER ALWAYS FREE FOR IMMEDIATE EGRESS, FULLY COMPLIANT W/ SECTION 1008.1.9.8. DOOR TYPES ' tt 1 1/2 PR HEAVY DUTY HINGES 1/2 PR ELECTRIC HINGE 1 ELECTRIC LOCKSET 3 SILENCERS 1 DOME FLOOR STOP 1 CLOSER 1 DOOR CONTACT (BY SECURITY) 1 PUSH BUTTON DOOR RELEASE (BY SECURITY), LOCATE BUTTON IN S.O.C. 1 CARD READER (BY SECURITY) 1 MOTION DETECTOR (BY SE GROUP #3 BULLETGUARD SINGLE, ALWAYS FREE FOR IMMEDIATE EGRESS W/ PANIC BAR, FULLY COMPLIANT W/ SECTION 1008.1.4A. 1 1/2 PR HEAVY DUTY HINGES 1/2 PR ELECTRIC HINGE 1 ELECTRIC LOCKSET 3 SILENCERS 1 DOME FLOOR STOP 1 CLOSER 1 PANIC BAR 1 DOOR CONTACT (BY SECURITY) 1 PUSH BUTTON DOOR RELEASE (BY SECURITY), LOCATE BUTTON IN S.O.C. 1 CARD READER (BY SECURITY) 1 MOTION DETECTOR (BY SECURITY) GROUP #4 S.O.C. 1 1/2 PR HEAVY DUTY HINGES 1/2 PR ELECTRIC HINGE 1 ELECTRIC LOCKSET 3 SILENCERS 1 DOME FLOOR STOP 1 CLOSER 1 DOOR CONTACT (BY SECURITY) 1 PUSH BUTTON DOOR RELEASE (BY SECURITY), LOCATE BUTTON IN S.O.C. 1 CARD READER (BY SECURITY) co STEEL STEEL BULLET GUARD SINGLE FULL -CITE LEVEL 3 POLY - CARBONATE BULLET RESISTANT W/ BRUSHED ALUMINUM FINISH STEEL BULLET GUARD SINGLE LEVEL 3 POLY - CARBONATE BULLET RESISTANT W/ BRUSHED ALUMINUM FINISH FRAME TYPES n n STEEL 3'-4" 3' �`2" STEEL REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2012 City of Tukwila BUILDING DIVISION RECtIvE0 CITY OF TUKWILA NOV 2 7 2012 PERMIT CENTER CONSULTANT FIRM MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 CenturyLink GEO LOC ID FLOOR FIRST BuLDG rUKWILA CYBER - INTERIOR UPGRADES STREET ADDRESS 6101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRIPfON SCHEDULES & DETAILS STAMP ISSUED FOR CONSTRUCTION PERMIT REVISIONS CONSULTANT NAME NOTICE The Information contained herein should not be disclosed lo unauthorized persons. It M meant for use by authorized represenlaWes of CenturyLink. No. DESCRIPTION DATE DRAWN BY CITY COMMENTS 11/19/2012 DATE CHECKED BY REVISED BY SCALE AP 10/12/12 BP BP /AP INDICATED CASE NUMBER JOB NO. 128296 FILE NAME SHEET NO. A -601 P:IProject1128296_Centuryl inILNDC Tukwila105_Deliverables101 Drawings108_AiprchitecturelTukwila _l- 601.dwg [36X24] Nov 21, 2012 - 10:47am Initials: ARNOLD.PALACIOS N N O c 0 N to a) 0 m 46 0) m 0 U 0 a 0 CU N 0 L co to VAV DISCHARGE DUCTWORK SADDLE TAP SYMBOL MECHANICAL LEGEND DESCRIPTION SYMBOL DESCRIPTION EXISTING WORK TO REMAIN e CONNECT TO EXISTING • • • • EXISTING WORK TO BE REMOVED IM, SUPPLY DUCT UP NEW WORK V RA, OA, OR EXH. DUCT UP RISE OR DROP 0 ROUND DUCT -.c PIPE BRANCH TOP CONNECTION FLAT OVAL DUCT - - -F 1 PIPE BRANCH BOTTOM CONNECTION SPIN -IN FITTING EXTRACTOR AND BALANCE ANCE QAMPER , -CWR- CHILLED WATER RETURN +-441: ELBOW WITH TURNING VANES - CWS - CHILLED WATER SUPPLY FIRE DAMPER -HWR- HOT WATER RETURN MAN. DAMPER HOT WATER SUPPLY - HWS - -4-- CONCENIRK: REDUCER SPRINKLER HEAD 0 THERMOSTAT �® -...\115 \--- �J FLEX DUCT T TEMPERATURE SENSOR DEFINITIONS 1. "INDICATED ": REQUIREMENTS EXPRESSED BY GRAPHIC REPRESENTATIONS OR IN WRITTEN FORM ON DRAWINGS, IN SPECIFICATIONS, AND IN OTHER CONTRACT DOCUMENTS. OTHER TERMS INCLUDING "SHOWN," "NOTED." °SCHEDULED," AND "SPECIFIED" HAVE THE SAME MEANING AS INDICATED." 2. "FURNISH ": SUPPLY AND DELIVER TO PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS. 3. "INSTALL ": OPERATIONS AT PROJECT SITE INCLUDING UNLOADING, TEMPORARILY STORING, UNPACKING, ASSEMBLING, ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS. 4. ''PROVIDE": FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE. SEAL JOINTS WITH DUCT MASTIC (TYP.) HARD ROUND DUCT DUCT INSULATION TAP INTO EXISTING VAV DISCHARGE DUCT e MANUAL BALANCING DAMPER INSULATED FLEXIBLE DUCT EXISTING SQUARE CEIUNG DIFFUSER REINSTALLED BY MECHANICAL CONTRACTOR NOTE: SEE PLANS FOR ACTUAL DUCT SIZES. SECURE FLEX DUCT TO ELBOW AND DIFFUSER WITH Xi" GALVANIZED ADJUSTABLE BAND CLAMPS WITH CADMIUM PLATED BUCKLE AND SCREWS WITH SLOTTED HEX HEAD. PLACE BAND CLAMPS BETWEEN THE WIRES OF LAST SPIRAL OF THE FLEX DUCT. SECURE FLEX DUCT TO SPIN -IN COLLAR AND AIR DEVICE COLLAR WITH SHEET METAL SCREWS. MAXIMUM LENGTH OF FLEX DUCT IS 7'. NL 2.0(24" CEILING GRID CEILING DIFFUSER CONNECTION M -001 N. T. S. MECHANICAL ABBREVIATIONS AB. A.D. A.F.F. APPROX. ATC AUTO. CONT. BTM. BLDG. BAS CAB. CAP. C.B. C.I. CLG. CH CONC. C.O. CONN. CONTR. CONT. CONY. COORD. CRAC DTL DIA. DIFF. DISCH. DN. D.S. EC ELEC. E.W.C. ELEM. ELEV. EXH EXIST. FT. HD. FIN. RAD. F. DPR. F. E. F.E.C. F.H.C. FLEX. F & T FLR. F.D. FURN. GA. GEN. GRAV. ABOVE ACCESS DOOR ABOVE FINISHED FLOOR APPROXIMATELY AUTOMATIC TEMPERATURE CONTROL AUTOMATIC CONTROL BOTTOM BUILDING BUILDING AUTOMATION SYSTEM CABINET CAPACITY CATCH BASIN CAST IRON CEILING CEILING HEATER CONCRETE CLEAN OUT CONNECT CONTRACTOR CONTINUATION CONVECTOR COORDINATE COMPUTER ROOM MR CONDITIONER DETAIL DIAMETER DIFFUSER DISCHARGE DOWN DOWNSPOUT ELECTRICAL CONTRACTOR ELECTRICAL ELECTRIC WATER COOLER ELEMENT ELEVATION EXHAUST EXISTING FEET OF HEAD FINNED RADIATION FIRE DAMPER FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FLEXIBLE FLOAT & THERMOSTATIC FLOOR FLOOR DRAIN FURNISH GAGE GENERAL GRAVITY GR. H.B. HTR. HTG. H & A/C INV. ELEV. J. R. LAV. MAN. DPR. M. H. MFR. MECH. MC MOP M. A. MID. NOM. OPNG. O.A. PLBG. PRESS. P.R.V. PROP. REG. RHC. REQD. REL R.A. R.D. RM. SCHED. S.D. SHT.MTL SH. S.I. S.S. STAT. S.A. S & R TEMP. THERM. TYP. T.C.C. UR. V.S.P. VIB. ISOL. V.T.R. w. w/ W.C. GRILLE HOSE BIBB HEATER HEATING HEATING & AIR CONDITIONING INVERT ELEVATION JANITOR RECEPTOR LAVATORY MANUAL DAMPER MANHOLE MANUFACTURER MECHANICAL MECHANICAL CONTRACTOR METHOD OF PROCEDURE MIXED AIR MOUNTED NOMINAL OPENING OUTSIDE NR PLUMBING PRESSURE PRESSURE REDUCING VALVE PROPELLER REGISTER REHEAT COIL REQUIRED RELIEF RETURN AIR ROOF DRAIN ROOM SCHEDULE SHOWER DRAIN SHEET METAL SHOWER SURFACE INLET SERVICE SINK THERMOSTAT SUPPLY MR SUPPLY & RETURN TEMPERATURE THERMOMETER TYPICAL TEMP. CONTROL CONTRACTOR URINAL VITRIFIED SEWER PIPE VIBRATION ISOLATOR VENT THRU ROOF WASTE WITH WATER CLOSET VAV DISCHARGE AIR DUCT FROM VAV 193 FIRE PROTECTION NOTES 1. ALL FIRE PROTECTION CONTRACT WORK IS TO COMPLY WITH THE APPLICABLE NFPA STANDARDS REFERENCED IN THE BUILDING CODE (OBC) AS ADMINISTERED BY THE LOCAL REVIEW /INSPECTION /APPROVAL AUTHORITIES, THE INSURANCE UNDERWRITER'S GUIDELINES, THE LOCAL FIRE PREVENTION AUTHORITY (FIRE MARSHALL'S OFFICE /FIRE DEPARTMENT), AND ANY OTHER AUTHORITIES HAVING JURISDICTION, AS CONFIRMED AND VERIFIED IN ADVANCE BY THE UCENSED FIRE PROTECTION CONTRACTOR. 2. COORDINATE THE REMOVAL AND ADDITION OF PIPING AND SPRINKLER HEADS WITH THE MECHANICAL AND ELECTRICAL CONTRACTOR. 3. INSTALL NEW SPRINKLER HEADS WHERE ADDITIONAL HEADS ARE NEEDED TO MAINTAIN COVERAGE AND WHERE EXISTING HEADS ARE TO BE RELOCATED. THE REUSE OF EXISTING SPRINKLER HEADS ARE ONLY PERMITTED WHERE EXISTING SPRINKLER HEADS ARE TO REMAIN. 4. FIRE PROTECTION CONTRACTOR SHALL FIELD VERIFY AND SECURE ALL MEASUREMENTS AND CONDITIONS BEFORE PROCEEDING WITH NEW INSTALLATION AND ANY MODIFICATIONS TO EXISTING SYSTEM. 5. THE SPRINKLER SYSTEM SHALL BE HYDRAULICALLY DESIGNED AND SIZED ACCORDING TO NFPA PAMPHLET NO. 13, THE APPUCATION BUILDING CODE AND THE INSURER'S GUIDEUNES, RULES AND REGULATIONS (REQUIRED FOR APPROVAL). 6. ALL SPRINKLER PIPING AND FITTINGS SHALL BE SCHEDULE 40, SEAMLESS, GALVANIZED WITH THREADED FITTINGS. 7. ALL EXISTING SPRINKLER HEADS TO REMAIN ARE TO BE FIELD VERIFIED BY THE FIRE PROTECTION CONTRACTOR IN ADVANCE. COORDINATE ALL NEW SPRINKLER DROPS FOR HEAD LOCATIONS WITH EXISTING AND NEW DUCTWORK, PIPING, AND EQUIPMENT. FPC SHALL SUBMIT SHOP DRAWINGS INDICATING NEW SPRINKLER HEAD LOCATIONS, TO THE ARCHITECT FOR REVIEW AND APPROVAL. 8. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR FIRESTOPPING AT ALL FIRE PROTECTION RELATED PENETRATIONS OF FIRE AND SMOKE RATED WALLS AND PARTITIONS. REFER TO ARCHITECTURAL FLOOR PLANS FOR LOCATIONS OF ALL RATED STRUCTURES. 9. RUN ALL PIPING IN FINISHED AREAS CONCEALED WHEREVER POSSIBLE. 10. ALL PIPING SHOWN IS ABOVE CEILING IN AREAS WITH DROPPED CEIUNGS. 11. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR REVIEWING ARCHITECTURAL PROJECT DOCUMENTATION FOR ITEMS AFFECTING FIRE PROTECTION WORK, INCLUDING SPECIFIC DIRECTIONS AND ITEMS OF A GENERAL NATURE, WHICH MAY NOT BE REFERRED TO BY THE FIRE PROTECTION DOCUMENTATION. THIS MAY INCLUDE. BUT IS NOT LIMITED TO, SPRINKLER REQUIREMENTS TO MAINTAIN RATED SEPARATION STRUCTURES (WALLS, WINDOWS. GLASS PARTITIONS /DOORS, ETC.), OR AT PROTECTION FEATURES SUCH AS DRAFTSTOPS AND OTHER STRUCTURAL ELEMENTS. WHERE THERE IS A DISCREPANCY IN LOCATIONS INDICATED BETWEEN THE TWO SETS OF DOCUMENTATION, THE LOCATION INDICATED BY THE ARCHITECTURAL SHALL TAKE PRECEDENT. ARCHITECTURAL REVIEW SHALL INCLUDE COMPLETE DOCUMENTATION, INCLUDING SPECIFICATIONS AND DRAWING ELEVATIONS. 12. FIRE PROTECTION CONTRACTOR SHALL CAP PIPING AND CLOSE VALVES WHERE NECESSARY AND RETURN THE LOCAL SYSTEM TO ACTIVE DUTY AT THE END OF EACH WORK DAY. 13. A COMPLETED CONTRACTORS MATERIAL AND TEST CERTIFICATE SHALL BE PROVIDED UPON COMPLETION OF THE PROJECT. 14. PROVIDE ESCUTCHEON COVER PLATES FOR ALL NEW SPRINKLER HEADS. 15. IN AREAS WHERE CEILING GRID IS INSTALLED, FIRE PROTECTION CONTRACTOR SHALL PROVIDE AND INSTALL SPRINKLER HEADS TO MATCH EXISTING HEADS IN AREA. 16. FIRE PROTECTION CONTRACTOR SHALL AT NO TIME INSTALL HEADS IN SOFFIT. RELOCATE OR PROVIDE NEW IN CEIUNG AREA ONLY. 17. UNLESS DIRECTED OTHERWISE, WHERE EXISTING STRUCTURE IS BEING REMOVED /REMODELED OR OTHERWISE REVISED, THE FIRE PROTECTION CONTRACTOR SHALL REVISE THE EXISTING SPRINKLER INSTALLATION AND PROVIDE NEW FIRE PROTECTION ITEMS /ELEMENTS AS REQUIRED TO PROVIDE /MAINTAIN THE COVERAGE SPECIFIED HEREIN. THIS INCLUDES SPACING AND LOCATION REQUIREMENTS (MINIMUM /MAXIMUM) BETWEEN SPRINKLER HEADS /PIPING AND RELATIVE TO WALLS, SOFFITS, PARTITIONS AND ANY OTHER OBSTRUCTIONS TO SPRINKLER DISCHARGE. IN AREAS WHERE EXISTING WALLS ARE REMOVED, MODIFY EXISTING AND PROVIDE NEW SPRINKLER HEADS TO ALIGN WITH EXISTING GRID PATTERN. ROUND AIR DUCT TO 315 CFM DIFFUSER NOTE: SEE PLANS FOR ACTUAL DUCT SIZES. CONICAL SADDLE TAP CONNECTED INTO VAV k---CONICAL AIR DUCT FROM VAV 193 DUCTWORK CONNECTION DETAIL M-001 N. T. S. SEPARATE PERMIT AND APPROVAL REQUIRED GENERAL NOTES 1. THE CONTRACTOR SHALL OBSERVE ALL FIRE AND LIFE SAFETY RULES, INCLUDING THE USE OF APPROVED AND CERTIFIED FIRE EXTINGUISHERS, PLACEMENT OF FIRE BLANKETS, THE USE OF INDEPENDENT FIRE WATCH PERSONNEL, CONTAINMENT, AND THE PROPER NOTIFICATION OF THE OWNER REPRESENTATIVE PRIOR TO THE START OF WORK. 2. WHEN WORKING IN THE BUILDING THE CONTRACTOR SHALL NOTIFY THE OWNER AND REQUEST THAT THE FIRE ALARM SYSItM BE PUT INTO THE TEST OR BYPASS MODE. THE CONTRACTOR SHALL CONFIRM WITH THE OWNER THAT THE PROPER FIRE ALARM MONITORING AUTHORITIES HAVE BEEN NOTIFIED. PERFORM NO WORK UNTIL VERIFICATION OF THIS PROCEDURE IS COMPLETE. 3. THERE WILL BE NO UNSCHEDULED SHUTDOWNS OF THE OWNERS SERVICES OR OF THE SERVICES EXTENDED FOR OWNERS CUSTOMERS. 4. ALL WORK SHALL. BE SUPERVISED BY A DIRECT EMPLOYEE OF THE CONTRACTOR, AUTHORIZED TO SUPERVISE THE WORK, IMPLEMENT THE NECESSARY PROTECTION MEASURES, CURTAIL UNSAFE OR IMPROPER WORK PROCEDURES, AND FULLY INFORMED OF THE NATURE OF THE FACILITY AND THE SPECIAL PRECAUTIONS REQUIRED TO PERFORM WORK IN THE BUILDING. 5. THE CONTRACTOR SHALL PROVIDE THE OWNER'S REPRESENTATIVE WITH A COMPLETE UST OF EMPLOYEES WHO WILL BE IN THE FACILITY, AND A LIST OF THE SUBCONTRACTORS (AND THEIR EMPLOYEES) PRIOR TO THE START OF WORK. ALL WORK SHALL BE PERFORMED BY DIRECT EMPLOYEES OF THE CONTRACTOR, OR BY DIRECT EMPLOYEES OF THE APPROVED SUBCONTRACTOR. THE OWNER RESERVES THE RIGHT TO PROHIBIT ANY EMPLOYEE OR SUBCONTRACTOR FROM WORKING ON SITE. 6. THE OWNER HAS THE RIGHT TO REFUSE ACCESS TO THE FACILITY IF IN HIS OPINION THE EMPLOYEE OR SUBCONTRACTOR POSES A RISK TO THE OWNERS SERVICES. 7. THE OWNER MAINTAINS A COMPREHENSIVE CONSTRUCTION GUIDELINE MANUAL THAT ADDRESSES ALL WORK RULES IN, ON, OR AROUND THE FACIU1 Y. 8. ON A DAILY BASIS, PRIOR TO ENTERING THE WORK AREA. THE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR AND INDICATE THE NATURE OF THE WORK AND THE AREA IN WHICH THE WORK WILL BE PERFORMED. 9. COORDINATE THE INSTALLATION AND USAGE OF PROTECTIVE BARRIERS WITH GENERAL CONTRACTOR. 10. COORDINATE THE REMOVAL AND RELOCATION OF HVAC ITEMS WITH ALL CONTRACTORS. 11. MECHANICAL CONTRACTOR SHALL COORDINATE THE DISPOSAL OF ALL REMOVED EQUIPMENT, MATERIALS, AND DEVICES WITH OWNER. 12. MAINTAIN A CLEAN AND ORGANIZED WORK AREA AND WHEN TERMINATING THE WORK AT THE END OF THE DAY. REINSTALL ALL CEIUNG TILES, COVER ALL OPENINGS, SWEEP AND REMOVE ALL DEBRIS, STORE ALL TOOLS AND MATERIALS IN APPROVED LOCATIONS, SET AND SECURE ALL SAFETY BARRIERS AS APPROPRIATE. 13. ALL WORK TO BE REMOVED AND INSTALLED PER ALL FEDERAL, STATE, AND LOCAL CODES. 14. REFER TO ARCHITECTURAL PLANS FOR EXISTING AND NEW REFLECTED CEIUNG PLANS AND DETAILS. 15. ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR INVOLVED. 16. ALL EQUIPMENT SHOWN ON THIS SHEET IS EXISTING TO REMAIN UNLESS NOTED OTHERWISE. 17. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF WORK, IF ANY DISCREPANCIES ARE FOUND, NOTIFY THE ENGINEER IN WRITING. 18. MECHANICAL CONTRACTOR RESPONSIBLE FOR REPAIR OF ANY DAMAGE TO CEILING TILES AND /OR CEIUNG GRID DUE TO REMOVAL AND RELOCATION OF THE HVAC ITEMS AND EQUIPMENT. 19. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING, CUTTING, AND RELOCATING ALL ITEMS AS CALLED OUT ON PLANS. COORDINATE WORK WITH ALL OTHER DISCIPLINES. 20. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL SYSTEM DOWN TIME AFTER HOURS, WITH OWNER. TO PERFORM ALL MODIFICATIONS NECESSARY AS PER THE SCOPE OF WORK CALLED OUT ON PLANS. 21. MECHANICAL CONTRACTOR SHALL FIELD VERIFY AND PERFORM ALL WORK NECESSARY TO ENSURE ALL CEILING MOUNTED HVAC ITEMS IN NEW CEIUNG GRID ARE PROPERLY INSTALLED IN CEILING TILES. 22. MECHANICAL CONTRACTOR DIFFUSER SCHEDULED TO MECHANICAL CONTRACTOR 23. MECHANICAL CONTRACTOR AND NEW VAV TERMINALS ENGINEER AT COMPLETION SHALL PROVIDE AN AIR FLOW TEST REPORT OF EACH BE RELOCATED. UPON COMPLETION OF RELOCATION WORK, SHALL RE- BALANCE AIR DEVICES TO ORIGINAL VALUES. SHALL BE RESPONSIBLE FOR RE- BALANCING THE EXISTING IF APPUCABLE. PROVIDE MR BALANCE REPORT TO OF PROJECT. 24. MECHANICAL CONTRACTOR SHALL NOTIFY PROJECT MANAGER AT THE COMPLETION OF THE DEMOLITION PHASE AND PRIOR TO ANY RELOCATION OR NEW WORK PERFORMED. b S- RECtIvEO CITY OF TUKWL.A Nov 2 7 2012 PERMIT CENTER MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 CONSULTANT FIRM NECHANICAUELECTRICAL ENGINEERING tK COMMUNICATIONS ENGINEERING CONSULTANTS P1,OENK, AZ I COLUMBUS, CH 2575 CAMEIBACK ROAD 6520 LAUFFER ROAD PNOQIDL ARIZONA 85015 COLU& US.ONO 43401 P202.347.7114 P9143922302 F23073132301 F9143922907 wwwasciriAlcom CenturyLink GEO LOC ID FLOOR BUILD �2fJ/� EILA CYBER - INTERIOR UPGRADES STREET�AJDDDREESb101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRIPTION ABBREVIATIONS & GENERAL NOTES STAMP ISSUED FOR CONSTRUCTION PERMIT REVISIONS CONSULTANT NAME NOTICE The Information contained herein should not be disclosed to unauthorized persons. N is meant for use by authorized representatives of CenturyUnk. No. DESCRIPTION DATE DRAWN BY DATE CHECKED BY JAG CASE NUMBER 10/12/12 NMO FILENAME REVISED BY SCALE N.T.S. JOB NO. 12033 SHEET NO. M -001 This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 BREAK ROOM MEN'S RESTROOM JANITOR'S CLOSET n F WOMEN'S RESTROOM 135 CFM DIFFUSER HALLWAY 1 EQUIPMENT ROOM 10 "0 VAV DISCHARGE DUCT RECEPTION AREA 16 "0 EXH. DUCT \ `/ 315 CFM DIFFUSER 01 / 14 "o VAV DISCHARGE DUCT L 10 "0 VAV DISCHARGE DUCT / VAV 193 STORAGE 315 CFM DIFFUSER 12 "0 VAV DISCHARGE DUCT L -4 \ y i: I IG -�I I ' VAV 203 SECURITY LOBBY 315 CFM DIFFUSER (-1- CONFERENCE ROOM DEMOLITION HVAC PLAN SCALE: 1/4" = MEN'S RESTROOM BREAK ROOM JANITOR'S CLOSET HALLWAY 2 WOMEN'S RESTROOM HALLWAY 1 EQUIPMENT ROOM RECEPTION AREA eig r---I---T--T---I-----r--I--T- I I I 1 1 1 1 1 1 1 1 1 1 J 1 L J 1 1 1 1 1 1 1 1 I 7 1 I 1 1 1 1 1 1 1 1 1 1 I 1 1 1 I 1 1 I 1 I I I I 1 1 1 1 1 — I 1 -- 1-- J - --1 1 1 -- -� - -1 1 I I 1 I I 1. 1 1 1 1-- 4-- 1--- I-- 4- - I I I I 1 1 1 - -I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 - -1- - -1 1 I I L I CONFERENCE ROOM SECURITY LOBBY / AREA OF WORK DEMOLITION FIRE PROTECTION PLAN SCALE: 1/4" = 1' -0" SEPARATE 4 PERMIT AND APPROVAL REQUIRED CODED NOTES 0 1. MECHANICAL CONTRACTOR SHALL REMOVE EXISTING SUPPLY AIR DEVICE FROM CEILING GRID AND DISCONNECT FROM DUCT. STORAGE OF THE AIR DEVICE SHALL BE COORDINATED WITH OWNER AND THE DEVICE SHALL BE CLEANED BEFORE BEING REINSTALLED. EXISTING DUCTWORK SHALL BE REMOVED AS NECESSARY AND MODIFIED FOR REUSE WHERE POSSIBLE. 2. MECHANICAL CONTRACTOR SHALL REMOVE SECTION OF EXISTING EXHAUST DUCT NECESSARY FOR INSTALLING NEW EXHAUST DUCTWORK. 3. FIRE PROTECTION CONTRACTOR SHALL REMOVE EXISTING SPRINKLER HEAD AND ASSOCIATED RUN OUT. LINE TYPE LEGEND EXISTING WORK TO REMAIN EXISTING WORK TO BE REMOVED KEY PLAN SCALE: N.T.S. REGtivku CITY OF TUK1111. A NOV 2 / 2012 PERMIT CENTER MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 STAMP CONSULTANT FIRM I .CHANICALIELECTRICAL ENGINEERING COMMUNICATIONS ENGINEERING CONSULTANTS PHOENIX. K 2575 CAMELRACK ROAD F1-10EN0( ARIZONA 85016 P9023437414 F8023437351 COLUMBUS. OH 6B20 U4.FFER ROAD COLUL0US, OHIO 43231 s+:r wmoselsiedow DESCRIPTION CenturyLink GEO LOC ID FLOOR But UKWILA CYBER - INTERIOR UPGRADES STREET ADDRE 6101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DEMOLITION MECHANICAL & FP PLANS ISSUED FOR CONSTRUCTION PERMIT REVISIONS CONSULTANT NAME NOTICE The Information contained herein should not be disclosed to unauthorized persons. It is meant for use by authorized representatives of CenturyL ink. No. DESCRIPTION DATE DRAWN BY JAG DATE 10/12/12 CHECKED BY NMO CASE NUMBER JOB NO. 12033 REVISED BY SCALE 1/4"=1-0" FILE NAME SHEET NO. M -101 This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 BREAK ROOM MEN'S RESTROOM JANITOR'S CLOSET HALLWAY 2 WOMEN'S RESTROOM 135 CFM DIFFUSER (I) HALLWAY 1 106 EQUIPMENT ROOM CEILING DIFFUSER CONNECTION 10"0 VAV DISCHARGE DUCT CEILING DIFFUSER CONNECTION 315 CFM DIFFUSER 315 CFM DIFFUSER( S.0.0 101 UNEW TAP (TYP. 2) 1 4"0 VAV DISCHARGE DUCT / 10 "0 VAV DI ICHARG =1 DUCT" / VAV 193 VAV 192 STORAGE I �I 16 "0 EXH. DUCT 5 eDUCTWORK CONNECTION (TYP. 2) KDUCT® CAP M.T. 103 (315 CFM DIFFUSER VAV 203 CONFERENCE ROOM 105 EIUNG DIFFUSER CONNECTION SECURITY LOBBY 104 M -001 16 "0 EXH. • DUCT HVAC PLAN BREAK ROOM MEN'S RESTROOM HALLWAY 2 1107 JANITOR'S CLOSET EQUIPMENT ROOM WOMEN'S RESTROOM HALLWAY 1 106 STORAGE T S.0.C. 101 eit I) L_ BYPASS 102 M.T. 103 r" CONFERENCE ROOM 105 SECURITY LOBBY 104 SCALE: 1 /4" = T Loy- AREA OF C) WORK FIRE PROTECTION PLAN SCALE: 1/4" = 1' -0" SEPARATE 4 PERMIT AND APPROVAL REQUIRED CODED NOTES 0 MECHANICAL CONTRACTOR SHALL INSTALL PREVIOUSLY REMOVED AND CLEANED SUPPLY AIR DEVICE. SUPPLY AIR DEVICE TO BE CONNECTED TO VAV DISCHARGE DUCT WITH PREVIOUSLY REMOVED CONNECTIONS AND DUCTWORK IF POSSIBLE. PROVIDE NEW 10 "0 SUPPLY DUCTWORK, SADDLE TAP, AND CONNECTION COMPONENTS WHERE NECESSARY TO MAKE CONNECTION. 2. MECHANICAL CONTRACTOR SHALL PROVIDE NEW 24 "X12" RETURN AIR DEVICE. MATCH EXISTING COLOR AND MODEL 3. MECHANICAL CONTRACTOR SHALL PROVIDE NEW TAP IN EXISTING VAV DISCHARGE DUCTWORK, SEAL ALL EDGES AND JOINTS WITH DUCT MASTIC. REPAIR INSULATION WHERE NECESSARY. 4. MECHANICAL CONTRACTOR SHALL COORDINATE DUCTWORK LOCATION WITH GENERAL CONTRACTOR AT INTERSECTION OF DUCTWORK AND NEW FULL HEIGHT WALL, PRIOR TO ANY GENERAL CONSTRUCTION WORK. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTING WALL AROUND DUCTWORK CREATING A DUCTWORK PENETRATION WHERE NECESSARY. MECHANICAL CONTRACTOR SHALL PROVIDE FIRE CAULKING AROUND ANY DUCTWORK PENETRATING A FIRE RATED WALL 5. MECHANICAL CONTRACTOR SHALL PROVIDE NEW EXHAUST DUCTWORK TO CONNECT TO EXISTING EXHAUST DUCTWORK. CONTRACTOR SHALL REUSE EXISTING DUCT SUPPORTS AND HANGERS WHERE POSSIBLE. 6. MECHANICAL CONTRACTOR SHALL CAP VAV DISCHARGE DUCT WITH SHEET METAL CAP. ALL JOINTS AND EDGES TO BE SEALED WITH DUCT MASTIC. CAP TO BE INSULATED. 7. FIRE PROTECTION CONTRACTOR SHALL PROVIDE NEW TAP, RUN OUT, ESCUTCHEON, AND SPRINKLER HEAD TO MATCH EXISTING. 8. FIRE PROTECTION CONTRACTOR SHALL PROVIDE ALL NECESSARY SPRINKLER PIPING AND SPRINKLER HEADS TO PROVIDE ADEQUATE COVERAGE IN COMPLIANCE WITH NFPA CODES AND REGULATIONS. LINE TYPE LEGEND EXISTING WORK TO REMAIN NEW WORK KEY PLAN SCALE: N.T.S. D sc2 RECEIvEi) CITY OF TWA .A NOV 2 7 2012 PERMIT CENTER MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279-1234 CONSULTANT FIRM MECHAMCJUJELECTRICAL ENGINEERING COMMUNICATIONS ENGINEERING CONSULTANTS PHOENCL K 2576 CAMELBACK ROAD PHOENDL ARIZONA 63016 P102.343. FM2.343 23O1 301 COLUMBUS, 011 6120 WiFFR ROAD COLUMBUS. 0H043= CenturyLink GEO LOC ID FLOOR BOI MILA CYBER - INTERIOR UPGRADES STREET ADDRE6101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRIPTION MECHANICAL & FP PLANS STAMP ISSUED FOR CONSTRUCTION PERMIT REVISIONS CONSULTANT NAME NOTICE The Information contained herein should not be dlsdosed to unauthorized persons. It is meant for use by authorized representatives of CenturyLink. No. DESCRIPTION DATE DRAWN BY JAG DATE 10/12/12 CHECKED BY NMO CASE NUMBER JOB NO. 12033 REVISED BY SCALE 1/4"=1'-0" FILE NAME SHEET NO. M -102 This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission 4 2012 BREAK ROOM 112 MEN'S RESTROOM 111 JANITOR'S CLOSET 110 WOMEN'S RESTROOM 109 RECEPTION AREA 101 HALLWAY 2 107 0100 CFM DIFFUSER 135 CFM 0 DIFFUSER HALLWAY 1 106 " ./ DISCHARG / DUCT 6 "0 VAV DISCHARGE DUCT 8 "0 VAV - DISCHARG DUCT I 75 CFM �/ DIFFUSER EQUIPMENT ROOM 108 I �AV 192 I YAV 193 �= -I 1 THERMOSTAT FOR VAV L.i 1930 CONFERENCE ROOM 105 SECURITY LOBBY 104 DEMOLITION HVAC PLAN BREAK ROOM 112 MEN'S RESTROOM JANITOR'S CLOSET 110 f AREA OF WORK WOMEN'S RESTROOM 109 HALLWAY 1 106 — !Ili — —T 1 T —'T r—'— T —'T (-- �j Itl'=�_ =_L =L _- _.1.=_L J =_ i_-t1 I -I -T r I-' 7 r -I -r- � � _ I�-II-- I _1- ©I -I - -1- ©I -II -n �- -1- -r r I- 7 r -r I III 1 1. 1 1 1 1. 1 1 tii —) 1 1 1 1 1 1 1 1 1 1 I I I I I I -1- --- 1-- 4-- }---- 1-- 4-- 1--- -1 - -4- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - -- I--- 1--- 1-- --- -- �-- l - --r- _J_ -1-_ I ©J - -J!R 08MIL— i ©-L 1 1 1 1 1 1 1 1 I I 1 1 1 1 1 1 1 1 - -- -- 4-- 1--- I--- i--- }-- -1 - -4- L I I I I I I I I 1 1 1 1 1 1 1 1 1 r--,--T--r--,---r--r---,---r- 1 1 1 1 1 1 1 1 l I I L I I i I J RECEPTION AREA 101 CONFERENCE ROOM 105 SCALE: 1/4" = 1'-0" SECURITY LOBBY 104 DEMOLITION FIRE PROTECTION PLAN SCALE: 1/4" = 1' -0" SEPARATE PERMITAND APPROVAL R QUIRED CODED NOTES 0 1. MECHANICAL CONTRACTOR SHALL REMOVE EXISTING SUPPLY AIR DEVICE FROM CEIUNG GRID AND DISCONNECT FROM DUCT. STORAGE OF THE AIR DEVICE SHALL BE COORDINATED WITH OWNER AND THE DEVICE SHALL BE CLEANED BEFORE BEING REINSTALLED. EXISTING DUCTWORK SHALL BE REMOVED AS NECESSARY AND MODIFIED FOR REUSE WHERE POSSIBLE. 2. MECHANICAL CONTRACTOR SHALL REMOVE EXISTING THERMOSTAT AND ASSOCIATED WIRING. THERMOSTAT TO BE STORED UNTIL RELOCATED. 3. FIRE PROTECTION CONTRACTOR SHALL REMOVE EXISTING SPRINKLER HEAD. ASSOCIATED RUN OUT SHALL BE REMOVED AS NECESSARY. LINE TYPE LEG EN D EXISTING WORK TO REMAIN EXISTING WORK TO BE REMOVED D�� 3s� RECtivku CITY OF TUK1 �+IL A NOV 2 l 2012 SCALE: N.T.S. CONSULTANT FIRM MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602)279.1234 GEO LOC Li FLOOR FIRST B/ILA CYBER — INTERIOR UPGRADES V4 CenturyLink STREETADDRESS101 SOUTH 180TH. STREET cmr, STATE TUKWILA, WA. 98188 DESCRIPTION DEMOLITION MECHANICAL & FP PLANS STAMP ISSUED FOR CONSULTANT NAME CONSTRUCTION PERMIT REVISIONS NOTICE The Informatlnn contgdned herein should not be disclosed to unauth rized persons. It is meant for use by authorized represei ves of Centuryunk. No. DESCRIPTION DATE DRAWN BY DATE JAG CASE NUMBER 10/12/12 CHECKED BY NMO FILENAME REVISED BY SCALE 1/4 " =1' -0" JOB NO. 12033 SHEET NO. M -1 03 This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 N BREAK ROOM 112 MEN'S RESTROOM 111 HALLWAY 2 0100 CFM DIFFUSER 107 JANITOR'S CLOSET 110 135 CFM DIFFUSER WOMEN'S RESTROOM 109 S.O.C. 101 HALLWAY 1 106 8"O VAV DISCHARGE DUCT I 6 "0 VAV DISCHARGE DUCT 8 "0 VAV - DISCHARG DUCT 75 CFM O1 DIFFUSER EQUIPMENT ROOM 108 BYPASS 102 M.T. 103 N---VAV 192 VAV 193 Cb THERMOSTAT FOR VAV 1930 CONFERENCE ROOM 105 SECURITY LOBBY 104 n u HVAC PLAN L L tXt AREA OF WORK O tEt n LJ SCALE: 1/4" = 1' -0" 1 FIRE PROTECTION PLAN SCALE: 1/4" = 1' -0" SEPARATE 4 PERMIT AND APPROVAL REQUIRED CODED NOTES 0 1. MECHANICAL CONTRACTOR SHALL INSTALL PREVIOUSLY REMOVED AND CLEANED SUPPLY AIR DEVICE. SUPPLY AIR DEVICE TO BE CONNECTED TO VAV DISCHARGE DUCT WITH PREVIOUSLY REMOVED CONNECTIONS AND DUCTWORK IF POSSIBLE. 2. MECHANICAL CONTRACTOR SHALL REINSTALL PREVIOUSLY REMOVED THERMOSTAT. NEW WIRING SHALL BE PROVIDED BY MECHANICAL CONTRACTOR. 3. FIRE PROTECTION CONTRACTOR SHALL PROVIDE NEW TAP, RUN OUT, ESCUTCHEON, AND SPRINKLER HEAD TO MATCH EXISTING. 4. FIRE PROTECTION CONTRACTOR SHALL PROVIDE ALL NECESSARY SPRINKLER PIPING AND SPRINKLER HEADS TO PROVIDE ADEQUATE COVERAGE IN COMPLIANCE WITH NFPA CODES AND REGULATIONS. LINE TYPE LEGEND EXISTING WORK TO REMAIN NEW WORK KEY PLAN SCALE: N.T.S. RECt►vE) CITY OF TUKiMiA NOV 2 7 2012 PERMIT CENTER CONSULTANT FIRM MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279-1234 CenturyLink GEO LOC ID FLOOR FIRST Bull-lit/MLA CYBER - INTERIOR UPGRADES MEET ADDRESa101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRIPTION MECHANICAL & FP PLANS STAMP ISSUED FOR CONSTRUCTION PERMIT REVISIONS CONSULTANT NAME NOTICE The InfamatIon contained herein should not be disclosed to unauthorized persons. It Is meant for use by authorized representatives of CenturyU*. No. DESCRIPTION DATE DRAWN BY JAG DATE 10/12/12 CHECKED BY NMO CASE NUMBER JOB NO. 12033 REVISED BY SCALE 1/4 " =1' -0" FILE NAME SHEET NO. M -104 This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission m 2012 O1 EXISTING —' DOUBLE SINK AND FAUCET SECURITY LOBBY 104 �na s gold EXISTING REFRIGERATOR BREAK ROOM 112 EXISTING HOT WATER HEATER MEN'S RESTROOM 111 0 JANITOR'S CLOSET 1110) HALLWAY 2 107 WOMEN'S RESTROOM 109 HALLWAY 1 106 EQUIPMENT ROOM 108 1 S.0.0 101 BYPASS 102 M.T. 1031 CONFERENCE ROOM 105 SECURITY LOBBY 104 DEMOLITION PLUMBING PLAN SCALE: 1/4" = 1' -0" r -� L J RELOCATED() DOUBLE SINK AND FAUCET NEW DISHWASHER® BREAK ROOM 112 RELOCATED REFRIGERATOR VENDING MACHINE (TYP. 2) EXISTING HOT • WATER HEATER MEN'S RESTROOM 111 HALLWAY 2 107 irj JANITOR'S CLOSET 11101 WOMEN'S RESTROOM 109 HALLWAY 1 106 EQUIPMENT ROOM 108 S.O.0 101 BYPASS 102 M.T. 103 CONFERENCE ROOM 105 SECURITY LOBBY 104 PLUMBING PLAN SCALE: 1/4" = 1' -0" SEPARATE 4 PERMIT AND APPROVIU. REQUIRED GENERAL NOTES 1. PLUMBING CONTRACTOR SHALL FIELD LOCATE ALL NECESSARY PIPING SERVICES PRIOR TO ANY PLUMBING WORK. PLUMBING CONTRACTOR SHALL SUBMIT AN AS —BUILT PLUMBING DRAWING OF THE AREA TO THE PROJECT ENGINEER FOR REVIEW. 2. PLUMBING CONTRACTOR SHALL VERIFY ALL PIPING SIZES NECESSARY TO CONNECT WITH NEW /RELOCATED EQUIPMENT. 3. PLUMBING CONTRACTOR SHALL INSTALL ALL NEW SERVICES, PIPING, FITTINGS AND SPECIALTIES IN ACCORDANCE WITH THE KING COUNTY PLUMBING CODE AND THE STATE OF WASHINGTON PLUMBING CODE. 4. ALL PIPING TO BE HIDDEN WITHIN WALLS AND CABINETRY WHERE POSSIBLE. 5. FINAL INSTALLATION OF PLUMBING FIXTURES AND DEVICES SHALL BE IN ACCORDANCE WITH THE CURRENT ADA REQUIREMENTS. THE PLUMBING CONTRACTOR SHALL VERIFY COMPLIANCE WITH THE CURRENT ADA CODE PRIOR TO THE FINAL INSTALLATION. 6. ALL PIPE INSULATION THAT IS DAMAGED OR REMOVED DURING THE DEMOLITION PROCESS SHALL BE REPAIRED WITH NEW INSULATING MATERIAL, COVERINGS AND JOINT SEALANTS. 7. THE EXISTING AND NEW DOMESTIC HOT AND COLD WATER PIPING SYSTEMS SHALL BE PROPERLY CLEANED AND FLUSHED PRIOR TO RETURNING THE PIPING SYSTEMS TO ACTIVE DUTY. UTILIZE A STANDARD CHLORINE BASED SANITIZER IN ACCORDANCE WITH COUNTY PLUMBING CODE STANDARDS. 8. ANY FLOOR CUTTING OR EXCAVATION NECESSARY FOR ACCESS TO PIPING SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR BACKFIWNG ANY AREA EXCAVATED WITH PEA GRAVEL. 9. BACKFLOW DEVICES SHALL BE INSTALLED AT EACH PIECE OF EQUIPMENT AS REQUIRED BY THE LOCAL PLUMBING CODE. CODED NOTES 0 1. PLUMBING CONTRACTOR SHALL REMOVE EXISTING SINK AND GARBAGE DISPOSAL. STORAGE OF THE SINK AND GARBAGE DISPOSAL SHALL BE COORDINATED WITH OWNER AND THE SINK SHALL BE CLEANED BEFORE BEING REINSTALLED. 2. PLUMBING CONTRACTOR SHALL REINSTALL PREVIOUSLY REMOVED SINK AND GARBAGE DISPOSAL IN NEW LOCATION. PLUMBING CONTRACTOR SHALL EXTEND DOMESTIC HOT AND COLD WATER PIPING TO SINK'S NEW LOCATION. PLUMBING CONTRACTOR SHALL INSTALL, LEVEL AND SEAL ALL FITMENTS, FAUCETS, AND CONNECTIONS — INCLUDING P —TRAPS AND HW /CW STOPS. PLUMBING CONTRACTOR SHALL PROVIDE INSULATION FOR HW AND CW PIPING TO MATCH EXISTING INSULATION. PLUMBING CONTRACTOR SHALL PROVIDE NEW CAST IRON VENT RISER AND SANITARY DROP AT SINK. EXTEND VENT TO EXISTING MAIN. EXTEND NEW SANITARY CAST IRON PIPING TO EXISTING 11E—IN AT SANITARY MAIN. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING PIPE CONNECTION SIZES TO SINK. 3. PLUMBING CONTRACTOR SHALL EXTEND EXISTING PIPING SERVICES FROM THE SINK TO NEW DISHWASHER. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE NECESSARY PIPING SERVICES NEEDED AND PIPE CONNECTION SIZES BASED ON SELECTED DISHWASHER MODEL. LINE TYPE LEGEND EXISTING WORK TO REMAIN EXISTING WORK TO BE REMOVED NEW WORK RECtivti) CITY OF TUKWILA NOV 272012 PERMIT CENTER KEY PLAN SCALE: N.T.S. CONSULTANT FIRM MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 GEOLOCL - FLOOR FIRST B RMILA CYBER - INTERIOR UPGRADES ;4; ' CenturyLink STREET AoDRES6101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRIPTION PLUMBING PLAN STAMP ISSUED FOR CONSULTANT NAME CONSTRUCTION PERMIT REVISIONS NOTICE The Information contained herein should not be disclosed to unauthorized persons. h is meant for use by authorized represenfalives of CenturyLink. No. DESCRIPTION DATE DRAWN BY DATE CHECKED BY JAG CASE NUMBER 10/12/12 NMO FILENAME REVISED BY SCALE 1/4"=V-0" JOB NO. 12033 SHEET NO. P -101 This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 LI N ETYP E LEGEND NEW /RELOCATED LOCATION EXISTING TO BE REMOVED /RELOCATED EXISTING CODED NOTES 0 1. PROVIDE ELECTRICAL BOXES AND CONDUIT FOR SECURITY DEVICES. COORDINATE EXACT LOCATION AND QUANTITY IN -FIELD WITH SECURITY CONTRACTOR PRIOR TO START OF WORK. PROVIDE PULL STRING IN EACH CONDUIT. FIXTURE SCHEDULE NOTE: FIXTURE NUMBER INDICATES MOUNTING AS FOLLOWS CL- CEILING MTD; R- RECESSED CEILING ELECTRICAL ABBREVIATIONS AWG AMERICAN WIRE GAUGE GEN GENERATOR A AMPERE GF GROUND FAULT AB ABOVE HT HEIGHT AUX AUXILIARY HTG HEATING BRD BOARD IC INTERCOM BRKR BREAKER JUNC JUNCTION BLDG BUILDING LTG LIGHTING CAB CABINET MH MANHOLE CLG CEILING MFGR MANUFACTURER CIRC CIRCUIT MECH MECHANICAL CONC CONCRETE MTD MOUNTED COND CONDUIT MTG MOUNTING CONN CONNECTION /CONNECTOR OPER OPERATOR /OPERATED CONT CONTROL PLBG PLUMBING CONTR CONTRACTOR PNL PANEL COORD COORDINATE PB PUSHBUTTON DIAG DIAGRAM RECEPT RECEPTACLE DISC DISCONNECT REQ'D REQUIRED ELEC ELECTRICAL STAT THERMOSTAT EC ELECTRICAL CONTRACTOR SW SWITCH ELEV ELEVATOR SWBD SWITCHBOARD EM ERG EMERGENCY TELE TELEPHONE EXH EXHAUST TEMP TEMPERATURE FDR FEEDER TERM BD TERMINAL BOARD FA FIRE ALARM TRANS TRANSFER FIX FIXTURE TFMR TRANSFORMER FLUOR FLUORESCENT T.C.C. TEMP CONTROL CONTRACTOR FRACT FRACTIONAL WP WEATHERPROOF FSBL FUSIBLE LI N ETYP E LEGEND NEW /RELOCATED LOCATION EXISTING TO BE REMOVED /RELOCATED EXISTING CODED NOTES 0 1. PROVIDE ELECTRICAL BOXES AND CONDUIT FOR SECURITY DEVICES. COORDINATE EXACT LOCATION AND QUANTITY IN -FIELD WITH SECURITY CONTRACTOR PRIOR TO START OF WORK. PROVIDE PULL STRING IN EACH CONDUIT. FIXTURE SCHEDULE NOTE: FIXTURE NUMBER INDICATES MOUNTING AS FOLLOWS CL- CEILING MTD; R- RECESSED CEILING FIXTURE NUMBER DESCRIPTION MANUFACTURER CATALOG NUMBER (* INDICATES 277V) LAMPS REMARKS R -1 2' x4'- PARB- T8 FLUOR EXISTING EXISTING 3 -32W - R -2 2'x2' - PARB -T8 FLUOR COOPER 2EP3GX- 2U1- S44I - UN V- GL- ER82-U 2 -32W 1 CL -3E EXIT EXISTING EXISTING - - CL-4E EXIT COOPER APX7 -G - 1 NOTE: NEW FIXTURE WITH OWNER BEFORE PURCHASE. 1. COORDINATE 24V BY SECURITY CONTRACTOR �J 6 "x6 "x4" J -BOX ON SECURE SIDE OF DOOR J MOTION SENSOR ON SECURE SIDE OF DOOR DOOR DC ES 42" LAY -IN CEILING PUSH BUTTON DOOR RELEASE LOCATED IN S.O.C. TYPICAL DOOR HARDWARE WIRING DRAWN FROM EXIT SIDE SECURITY NOTES 1. INGRESS AND EGRESS BY CARD READER. DOOR POSITION SWITCHES TIED INTO BUILDING SECURITY SYSTEM. 2. ALL SECURITY WIRING SHALL BE INSTALLED IN MINIMUM 3/4" EMT WHEN INSTALLED IN OR THROUGH UNSECURED ROOMS. ALL OTHER CABLES CAN BE INSTALLED UTILIZING BRIDLE RINGS. COORDINATE EXACT CONDUIT RUN AND SIZE WITH SECURITY CONTRACTOR PRIOR TO START OF WORK. ELECTRICAL LEGEND SYMBOL 4) 43 •OS a IINI• O SMOKE DETECTOR, CEIUNG MOUNTED DESCRIPTION DUPLEX RECEPTACLE TOGGLE SWITCH, SINGLE, 3 -WAY OCCUPANCY MOTION SWITCH TELEPHONE /DATA OUTLET ELECTRICAL PANEL FIRE ALARM DEVICE - FIRE ALARM DEVICE - FIRE ALARM DEVICE - VISUAL AUDIOVISUAL AUDIO Q SPEAKER, CEILING RECESSED • SPRINKLER MECHANICAL SUPPLY DIFFUSER MECHANICAL RETURN DIFFUSER DOOR CONTACT DOOR STRIKE CARD READER PUSH TO EXIT BUTTON MOTION SENSOR DC CENTER HEIGHT 18" 42" 42" 18" 6' -0" TO TOP SEE DRAWINGS SEE DRAWINGS SEE DRAWINGS PROVIDED BY OTHERS PROVIDED BY OTHERS 42" 42" CAMERA - POWER OVER ETHERNET LIGHTING LEGEND 0 O ALL UGHTING ASSOCIATED WITH THIS SYMBOL ARE R -1. SCHEDULE FOR DETAILS. ALL UGHTING ASSOCIATED WITH THIS SYMBOL ARE R -2. SCHEDULE FOR DETAILS. ALL UGHTING ASSOCIATED WITH THIS SCHEDULE FOR DETAILS. ALL UGHTING ASSOCIATED WITH THIS SCHEDULE FOR DETAILS. SEE FIXTURE SEE FIXTURE SYMBOL ARE CL -3E. SEE FIXTURE SYMBOL ARE CL -4E. SEE FIXTURE GENERAL NOTES 1. THE CONTRACTOR SHALL PROVIDE THE OWNER'S REPRESENTATIVE WITH A COMPLETE LIST OF EMPLOYEES WHO WILL BE IN THE FACILITY, AND A UST OF THE SUBCONTRACTORS (AND THEIR EMPLOYEES) PRIOR TO THE START OF WORK. ALL WORK SHALL BE PERFORMED BY DIRECT EMPLOYEES OF THE CONTRACTOR, OR BY DIRECT EMPLOYEES OF THE APPROVED SUBCONTRACTOR. THE OWNER RESERVES THE RIGHT TO PROHIBIT ANY EMPLOYEE OR SUBCONTRACTOR FROM WORKING ON SITE. 2. THE OWNER MAINTAINS A COMPREHENSIVE CONSTRUCTION GUIDELINE MANUAL THAT ADDRESSES ALL WORK RULES IN, ON, OR AROUND THE FACILITY. 3. MAINTAIN A CLEAN AND ORGANIZED WORK AREA WHEN WORKING AND WHEN TERMINATING THE WORK AT THE END OF THE DAY. SWEEP AND REMOVE ALL DEBRIS, STORE ALL TOOLS AND MATERIALS IN APPROVED LOCATIONS, SET AND SECURE ALL SAFETY BARRIERS AS APPROPRIATE. MAINTAIN A SHOP VACUUM WITH A HEPA FILTER IN THE WORK AREA AND PROVIDE FOR A DAILY REMOVAL OF ALL DEBRIS ON AND UNDER THE RAISED FLOOR. 4. COORDINATE FINAL LOCATION OF ALL EQUIPMENT WITH THE OWNER. 5. COORDINATE THE FINAL ROUTE OF CONDUITS IN ORDER TO AVOID CONFUCTS WITH EXISTING DEVICES & EQUIPMENT. 6. PROVIDE FOR CEIUNG REMOVAL AND REPAIR AS REQUIRED FOR THE INSTALLATION OF CONDUITS, ETC. 7. PROVIDE FOR CAULKING AND PATCHING OF THE WALL. CEIUNG & FLOOR FOR ALL CONDUIT PENETRATIONS. SEAL ALL PENETRATIONS WITH FIRE RATED CAULK. 8. ALL NEW CONDUCTORS SHALL BE CONTINUOUS WITHOUT ANY SPLICES. SPUCES ARE NOT ALLOWED IN ANY WIRING UNLESS A WRITTEN APPROVAL FROM THE ENGINEER IS PROVIDED. 9. THE LOCATION OF EQUIPMENTS /DEVICES SHOWN ARE APPROXIMATE. VERIFY EXACT LOCATION IN FIELD. 10. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO TRACE OUT CIRCUITS BEFORE DEMOLITION WORK BEGINS. 11. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO KEEP A CLEAN WORK AREA AND REPAIR ANY DAMAGE TO WALLS AND CARPET. 12. ELECTRICAL CONTRACTOR SHALL LABEL RECEPTACLES AND CONDUIT ON A PRINTED FORMAT. LABEL SHALL INCLUDES PANEL AND CIRCUIT NUMBER. 13. THE EXISTING CONDITIONS SHOWN WERE OBTAINED FROM OWNER PROVIDED RECORD DRAWINGS AND FIELD OBSERVATIONS. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF WORK, IF ANY DISCREPANCIES ARE FOUND, NOTIFY ENGINEER IN WRITING. 14. THE BRANCH CIRCUIT IDENTIFICATION SHOWN REPRESENTS THE DESIGN INTENT (QUANTITY AND SIZE OF BRANCH CIRCUIT). THE ELECTRICAL CONTRACTOR SHALL REUSE EXISTING BRANCH CIRCUIT BREAKERS OBTAINED FROM DEMOLITION. 15. THE ELECTRICAL CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO CIRCUIT BREAKER POLE LOCATIONS TO ACCOMMODATE THE CIRCUIT BREAKER TIES DEFINITIONS 1. "INDICATED ": REQUIREMENTS EXPRESSED BY GRAPHIC REPRESENTATIONS OR IN WRITTEN FORM ON DRAWINGS, IN SPECIFICATIONS, AND IN OTHER CONTRACT DOCUMENTS. OTHER TERMS INCLUDING "SHOWN," "NOTED." "SCHEDULED," AND "SPECIFIED" HAVE THE SAME MEANING AS INDICATED." 2. "FURNISH ": SUPPLY AND DELIVER TO PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS. 3. "INSTALL ": OPERATIONS AT PROJECT SITE INCLUDING UNLOADING, TEMPORARILY STORING, UNPACKING, ASSEMBUNG, ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION. FINISHING, CURING, PROTECTING. CLEANING, AND SIMILAR OPERATIONS. 4. "PROVIDE ": FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE. ELECTRICAL SPECIFICATIONS GENERAL PROVISIONS A. GENERAL 1. THE PARTY PERFORMING THE WORK UNDER THIS SECTION HEREINAFTER REFERRED TO AS THE CONTRACTOR, SHALL FURNISH ALL LABOR MATERIAL, TOOLS, EQUIPMENT, SERVICES, AND RELATED ACCESSORIES FOR A COMPLETE INSTALLATION OF ALL ELECTRICAL WORK AS INDICATED IN THE DRAWINGS AND SPECIFICATIONS. THIS INCLUDES BUT IS NOT UNITED TO ALL NECESSARY ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS AND OTHER SIMILAR APPURTENANCES NOT INDICATED ON THE DRAWINGS BUT ARE REQUIRED FOR A COMPLETE AND PROPERLY INSTALLED SYSTEM. ITEMS OMITTED FROM EITHER THE SPECIFICATIONS OR THE DRAWINGS, BUT SHOWN OR DESCRIBED IN THE OTHER, AND ALL NECESSARY TO MAKE THE ELECTRICAL SYSTEM COMPLETE AND WORKABLE SHALL FORM A PART OF THE WORK. 2. RACEWAY, WIRING, CABLING, PULL BOXES, JUNCTION BOXES, ETC. SHOWN IN THE CONTRACT DOCUMENTS ARE DIAGRAMMATIC IN NATURE TO SHOW INTENT ONLY. AS THE RESULT OF DIFFERENCES BETWEEN VARIOUS MANUFACTURERS' REQUIREMENTS, ALL RACEWAY, WIRING, AND CABUNG MAY NOT BE SHOWN ON THE DRAWINGS. IT IS THE RESPONSIBIUTY OF THE CONTRACTOR TO INCLUDE IN HIS /HER BID ANY ADDITIONAL RACEWAYS, WIRING, AND CABUNG REQUIRED FOR THE PROPER INSTALLATION AND OPERATION OF THE SYSTEMS BEING PROPOSED FOR USE ON THIS PROJECT. 3. ANY DISCREPANCIES WITHIN DRAWINGS AND SPECIFICATIONS SHALL BE PROMPTLY BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION DURING THE BIDDING PERIOD. NO ALLOWANCE SHALL SUBSEQUENTLY BE MADE TO THE CONTRACTOR BY REASON OF HIS FAILURE TO HAVE BROUGHT SAID DISCREPANCIES TO THE ATTENTION OF THE ENGINEER DURING THE BIDDING PERIOD OR OF ANY ERROR ON THE CONTRACTOR'S PART. 4. THE CONTRACTOR SHALL CHECK ALL EXISTING FIELD CONDITIONS (STRUCTURAL ARCHITECTURAL AND MECHANICAL TRADES WORK) FOR POSSIBLE INTERFACE CAUSED BY CONDITIONS IN THE FIELD BEFORE BID IS MADE. NO ALLOWANCE SHALL SUBSEQUENTLY BE MADE TO THE CONTRACTOR BY REASON OF HIS FAILURE TO HAVE MADE SUCH EXAMINATIONS OR OF ANY ERROR ON HIS PART. 5. THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO COMPARE THEM WITH THE CONTRACT DOCUMENTS AND TO HAVE SATISFIED HIMSELF AS THE CONDITIONS OF THE PREMISES, THE SITE, ANY OBSTRUCTIONS, THE ACTUAL LEVELS, ACCESS PANELS, AND ALL OTHER EXISTING CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD, SHALL CHECK LOCATION OF AND CONNECTIONS TO EXISTING FACIUTIES, AND SHALL ASSUME ALL RESPONSIBIUTY FOR SAME. 6. SHOULD ANY CHANGES IN THE DRAWINGS AND SPECIFICATIONS BE REQUIRED TO CONFORM TO THE ABOVE REGULATIONS, THE CONTRACTOR SHALL NOTIFY THE OWNER OR HIS REPRESENTATIVE AT THE TIME OF SUBMITTING HIS BID. AFTER ENTERING INTO THE OWNER - CONTRACTOR AGREEMENT, THE CONTRACTOR SHALL BE HELD TO COMPLETE ALL WORK NECESSARY TO MEET THESE REQUIREMENTS WITHOUT ADDITIONAL EXPENSE TO THE OWNER. 7. THE CONTRACTOR SHALL NOT ALLOW OR CAUSE ANY OF THE WORK TO BE COVERED UP OR ENCLOSED UNTIL IT HAS BEEN INSPECTED. ANY WORK THAT IS ENCLOSED OR COVERED UP BEFORE SUCH INSPECTION AND TEST SHALL BE UNCOVERED AT THE CONTRACTOR'S EXPENSE; AFTER IT HAS BEEN INSPECTED, THE CONTRACTOR SHALL RESTORE THE WORK TO ITS ORIGINAL CONDITION AT HIS OWN EXPENSE. 8. ALL GENERAL TRADES AND MECHANICAL DRAWINGS SHALL BE CHECKED BEFORE INSTALLING ANY OUTLETS, POWER WIRING, ETC. 9. ALL WORK SHALL BE DONE IN ACCORDANCE WITH CONTRACT DOCUMENTS, IN A NEAT AND WORKMANLIKE MANNER CONSISTENT WITH RECOGNIZED GOOD PRACTICE, AND SHALL BE SUBJECT TO THE APPROVAL OF THE OWNER OR HIS REPRESENTATIVE. 10. IF THE CONTRACTOR FAILS TO DO ANY REQUIRED PATCHING OR REPAIR ANY DAMAGE RESULTING FROM THE INSTALLATION OF THE ELECTRICAL WORK, SUCH PATCHING OR REPAIRING SHALL BE DONE BY THE OWNER AND THE COST SHALL BE PAID BY THE CONTRACTOR. 11. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES IN NEAT AND ORDERLY CONDITION AND REMOVE ALL DEBRIS RESULTING FROM THE WORK, AS WELL AS ALL TOOLS, EQUIPMENT. ETC., FROM THE SITE UPON COMPLETION OF THIS CONTRACT. ALL EQUIPMENT INCLUDING UGHTING FIXTURES AND LENSES SHALL BE CLEAN AND FREE FROM DIRT, GREASE, FINGER MARKS, ETC., BEFORE FINAL ACCEPTANCE. B. JOB -SITE COPY OF DOCUMENTS 1. MAINTAIN AT THE SITE, ONE COPY OF ALL DRAWINGS, SPECIFICATIONS, ADDENDA APPROVED SHOP DRAWINGS, CHANGE ORDERS AND OTHER MODIFICATIONS, IN GOOD ORDER AND MARKED TO RECORD ALL CHANGES MADE DURING CONSTRUCTION. THESE SHALL BE AVAILABLE TO THE OWNERS REPRESENTATIVE AT ALL TIMES. THE DRAWINGS MARKED TO RECORD ALL CHANGES MADE DURING CONSTRUCTION SHALL BE DELIVERED TO THE OWNER'S REPRESENTATIVE UPON COMPLETION OF THE WORK. C. SUBMITTALS 1. THE CONTRACTOR SHALL TURN OVER ALL CERTIFICATES OF APPROVAL FOR INSPECTIONS OF ELECTRICAL WORK TO THE OWNER PROMPTLY WHEN RECEIVED. THESE CERTIFICATES MUST BE RECEIVED BEFORE PAYMENT WILL BE MADE FOR THE WORK INVOLVED. 2. THE OWNER OR HIS REPRESENTATIVE RESERVES THE RIGHT TO REJECT ANY EQUIPMENT OR MATERIALS WHICH ARE NOT IN COMPUANCE WITH THESE SPECIFICATIONS, OR THE APPROVED SHOP DRAWINGS, EITHER BEFORE OR AFTER INSTALLATION AT NO EXPENSE TO THE OWNER AND EQUIPMENT SHALL BE REPLACED WITH APPROVED EQUIPMENT BY THE CONTRACTOR AT NO COST TO THE OWNER. 3. PROVIDE SHOP DRAWINGS FOR ALL MATERIALS USTED IN THIS SPECIFICATION. 4. THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR REVIEW, (4) COPIES OF MANUFACTURER'S DRAWINGS AND WIRING DIAGRAMS. THE ENGINEER WILL REVIEW CONTRACTOR'S SHOP DRAWINGS AND RELATED SUBMITTALS (AS INDICATED BELOW) WITH RESPECT TO THE ABILITY OF THE DETAILED WORK, WHEN COMPLETE, TO BE A PROPERLY FUNCTIONING INTEGRAL ELEMENT OF THE OVERALL SYSTEM DESIGNED BY THE ENGINEER. BEFORE SUBMITTING A SHOP DRAWING OR ANY RELATED MATERIAL TO THE ENGINEER, CONTRACTOR SHALL REVIEW EACH SUCH SUBMISSION FOR CONFORMANCE WITH THE MEANS. METHODS, TECHNIQUES, SEQUENCES, AND OPERATIONS OF CONSTRUCTION, AND SAFETY PRECAUTIONS THERETO, ALL OF WHICH ARE THE SOLE RESPONSIBIUTY OF CONTRACTOR; APPROVE EACH SUCH SUBMISSION BEFORE SUBMITTING IT; AND SO STAMP EACH SUCH SUBMISSION BEFORE SUBMITTING IT. THE ENGINEER SHALL ASSUME THAT NO SHOP DRAWING OR RELATED SUBMITTAL COMPRISES A VARIATION UNLESS CONTRACTOR ADVISES ENGINEER OTHERWISE VIA A WRITTEN INSTRUMENT WHICH IS ACKNOWLEDGED BY ENGINEER IN WRITING. THE ITEMS, TYPES OF SUBMITTALS AND RELATED MATERIAL (IF ANY) CALLED FOR ARE INDICATED BELOW: ITEMS TYPE SUBMITTALS REQUIRED CONDUIT WIRE SINGLE POLE SWITCH DUPLEX RECEPTACLE FIRE ALARM DEVICE D. GUARANTEES CATALOG CUTS CATALOG CUTS CATALOG CUTS CATALOG CUTS CATALOG CUTS 1. ALL EQUIPMENT FURNISHED AND WORK PERFORMED UNDER THE CONTRACT DOCUMENTS SHALL BE GUARANTEED AGAINST DEFECTS IN MATERIALS OR WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF DM. ACCEPTANCE. ANY FAILURE OF EQUIPMENT OR WORK DUE TO DEFECTS IN MATERIALS OR WORKMANSHIP SHALL BE CORRECTED BY THE CONTRACTOR AT NO COST TO THE OWNER. EXISTING AND DEMOLITION WORK A. WORK INCLUDED 1. SUITABLY AND ADEQUATELY PROTECT THE EXISTING BUILDING ELEMENTS WITHIN, AND IMMEDIATELY ADJACENT TO, THE NEW WORK AREAS FROM DAMAGE AND INJURY DURING THE PROCESS OF INSTAWNG THE WORK UNDER THIS CONTRACT. EXISTING BUILDING ELEMENTS THAT HAVE BEEN HARMED, DAMAGED OR INJURED AS A RESULT OF THE ELECTRICAL CONTRACTOR'S WORK SHALL BE REPAIRED, RESTORED OR REPLACED AT THE ELECTRICAL CONTRACTOR'S EXPENSE. 2. THE CONTRACTOR SHALL REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, WIRING, AND CONDUIT BACK TO A POINT OF RECONNECTION IF THE SYSTEM IS TO BE USED IN THE AREAS TO BE REMODELED IN THIS PROJECT. IF THE SYSTEM IS NOT TO BE USED, REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, WIRING, AND CONDUIT IN THE AREA. 3. REMOVE ALL UNUSED CONDUCTORS FROM ABANDONED RACEWAY. 4. PROVIDE WIRE MARKERS TO IDENTIFY ALL EXISTING, REUSED, CONDUCTORS IN ACCESSIBLE BOXES. 5. WHERE EXISTING FIXTURES ARE CALLED FOR TO BE RELOCATED OR REUSED, THE CONTRACTOR SHALL REMOVE, STORE, CLEAN, RELAMP, REFURBISH, AND REINSTALL THEM AS INDICATED UNLESS OTHERWISE NOTED. REPLACE FAILED BALLASTS. ALL FIXTURES SHALL BE FULLY OPERATIONAL B. CUTTING AND PATCHING 1. PATCHING SHALL MATCH EXISTING SURFACES IN KIND AND FINISH AND IS THE RESPONSIBILITY OF THIS CONTRACTOR. 2. REPAIR OF DAMAGES, BY THE ELECTRICAL CONTRACTOR, TO NEWLY PATCHED AND REFINISHED AREAS SHALL BE DONE BY THIS CONTRACTOR & SHALL MATCH EXISTING CONDITION. 3. WHERE REQUIRED TO MAINTAIN FIRE RATING, OPENINGS SHALL BE SEALED UTILIZING 3M BRAND FIRE BARRIER PENETRATION SEALING SYSTEMS. ARE BARRIER OR FIRE STOP SYSTEMS FROM CROUSE- HINDS, THOMAS & BETTS OR DOW CORNING MAY BE USED AT CONTRACTOR'S OPTION. THIS INCLUDES HOLES LEFT DUE TO REMOVAL OF EXISTING CONDUITS, BUS DUCT, ETC. OPENINGS SHALL BE TEMPORARILY FIRE STOPPED UNTIL PERMANENT ARE STOPPING IS DONE. C. CLEANING AND PAINTING 1. ALL ELECTRICAL EQUIPMENT SHALL BE KEPT DRY AND CLEAN DURING THE CONSTRUCTION PERIOD. INTERIOR OF ALL ENCLOSURES SHALL BE CLEANED OF DIRT AND DEBRIS BEFORE INSTAWNG TRIM OR COVERS. 2. ALL FINISHED SURFACES OF EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL BE THOROUGHLY CLEANED OF DIRT AND ALL SCRATCHED OR DAMAGED SURFACES SHALL BE TOUCHED UP WITH MATCHING MATERIALS BEFORE FINAL ACCEPTANCE OF THE WORK. 3. WHEN ALL WORK IS COMPLETED AND ALL WORK HAS BEEN SATISFACTORILY TESTED AND ACCEPTED BY THE OWNER'S REPRESENTATIVE, ALL CONDUIT AND OTHER EXPOSED SURFACES SHALL BE THOROUGHLY CLEANED. CODES AND FEES A. CODES: 1. ALL WORK PERFORMED UNDER THIS SPECIFICATION SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AS PREPARED AND PUBUSHED BY THE NATIONAL FIRE PROTECTION ASSOCIATION AND ANY APPUCABLE STATE OR LOCAL CODES. B. FEES: 1. OBTAIN AND PAY FOR ANY AND ALL PERMITS REQUIRED BY ALL LAWS AND REGULATIONS AND PUBLIC AUTHORITY HAVING SUCH JURISDICTION. TESTS AND INSPECTIONS A. OBTAIN ALL INSPECTIONS REQUIRED BY ALL LAWS, ORDINANCES, RULES, REGULATIONS OR PUBUC AUTHORITY HAVING JURISDICTION AND OBTAIN CERTIFICATES OF SUCH INSPECTIONS AND SUBMIT SAME TO THE OWNER'S REPRESENTATIVE. PAY ALL FEES, CHARGES AND OTHER EXPENSES IN CONNECTION THEREIN. OBTAIN OCCUPANCY PERMIT AS REQUIRED BY OWNER. FINAL PAYMENT SHALL NOT BE MADE UNTIL OCCUPANCY PERMIT IS OBTAINED. B. WORK SHALL BE UNACCEPTABLE WHEN FOUND TO BE DEFECTIVE OR CONTRARY TO THE PLANS SPECIFICATIONS, CODES SPECIFIED OR ACCEPTED STANDARDS OF GOOD WORKMANSHIP. C. THE CONTRACTOR SHALL PROMPTLY CORRECT ALL WORK FOUND UNACCEPTABLE BY THE OWNER'S REPRESENTATIVE WHETHER OBSERVED BEFORE OR AFTER SUBSTANTIAL COMPLETION AND WHETHER OR NOT FABRICATED, INSTALLED OR COMPLETED. THE CONTRACTOR SHALL BEAR ALL COSTS OF CORRECTING SUCH UNACCEPTABLE WORK, INCLUDING COMPENSATION FOR THE OWNERS REPRESENTATIVE ADDITIONAL SERVICES MADE NECESSARY THEREBY. WIRE AND CABLE A. ALL CONDUCTORS SHALL BE STRANDED AND OF THE AWG SIZE AND TYPE SHOWN ON THE DRAWINGS. WHERE NO SIZE OR TYPE IS SHOWN, CONDUCTORS SHALL NOT BE LESS THAN #12 TYPE XHHW, THHN, OR THWN. ALL CONDUCTORS SHALL BE COPPER AND HAVE 600 VOLT INSULATION; BE UL LABELED AND OF AMERICAN MANUFACTURER. B. ALL CONNECTIONS ARE TO BE MADE USING PRESSURE TYPE TERMINALS. C. THE FOLLOWING COLOR CODE SHALL BE USED: PHASE A PHASE B PHASE C NEUTRAL EQUIPMENT GROUND 120/208 VOLT BLACK RED BLUE WHITE GREEN 277/480 VOLT BROWN ORANGE YELLOW GRAY GREEN D. ALL CONDUCTORS SHALL HAVE CONTINUOUS INSULATION COLOR AS NOTED ABOVE. E. ALL BRANCH CIRCUITS SHALL BE MARKED IN THE PANELBOARD GUTTERS. MARKERS SHALL INDICATE CORRESPONDING BRANCH - CIRCUIT NUMBERS. F. EACH BRANCH CIRCUIT REQUIRING A NEUTRAL SHALL BE FURNISHED WITH A SEPARATE INDIVIDUAL NEUTRAL CONDUCTOR. BOXES AND PLATES A. FURNISH AND INSTALL ALL OUTLET, JUNCTION, AND PULLBOXES AS INDICATED ON THE DRAWINGS AND AS NECESSARY TO INSTALL THE REQUIRED CONDUIT AND WIRING IN A NEAT AND WORKMANUKE MANNER. B. JUNCTION BOXES SHALL BE GALVANIZED AND OF THE CORRECT SIZE AND GAUGE, IN ACCORDANCE WITH CODE REQUIREMENTS AND SHALL BE U.L LABELED. C. FLUSH OUTLET, JUNCTION SHALL BE PRESSED STEEL GALVANIZED OR SHERARDIZED AND SHALL BE A MINIMUM OF 4" SQUARE OR OCTAGONAL SIMILAR TO APPLETON #40. D. ALL BOXES SHALL BE RIGIDLY SUPPORTED FROM BUILDING STRUCTURE INDEPENDENT OF THE CONDUIT SYSTEM. BOXES CAST INTO MASONRY OR CONCRETE ARE CONSIDERED TO BE RIGIDLY SUPPORTED. WIRING DEVICES A. WIRING DEVICES SHALL BE HEAVY DUTY, SPECIFICATION GRADE AS MANUFACTURED BY BRYANT, HUBBELL, LEVITON. ALL DEVICES SHALL HAVE A IVORY FINISH. B. SWITCHES SHALL BE SINGLE POLE AS INDICATED. SWITCHES SHALL BE TOGGLE, RATED 20 AMPERE, 120/277 VOLT. C. RECEPTACLES SHALL BE DUPLEX, 2 POLE, 3 WIRE, NEMA 5 -20R, GROUNDING TYPE, RATED 20 AMPERE, 125 VOLT. RECEPTACLE FACE SHALL BE CONSTRUCTED OF IMPACT RESISTIVE NYLON. D. ALL SWITCHES AND RECEPTACLES SHALL BE FLUSH MOUNTED. ALL OUTLETS ARE TO BE FITTED WITH DEVICE PLATES THAT COMPLETELY CONCEAL THE OPENINGS. E. ALL SWITCHES SHALL BE "OFF" IN THE DOWN POSITION. F. ELEVATIONS FOR OUTLETS FROM FINISHED FLOOR TO CENT OF OUTLET SHALL BE AS FOLLOWS, EXCEPT WHERE OTHERWISE NOTED: 1. SWITCHES: 4' -0" 2. RECEPTACLES IN FINISHED SPACES: 1' -6" G. CHECK ALL DOOR SWINGS SO THAT LIGHT SWITCHES ARE NOT LOCATED BEHIND DOORS. RELOCATE SWITCHES AS REQUIRED, WITH APPROVAL FROM THE OWNER OR HIS REPRESENTATIVE. H. GROUND ALL RECEPTACLES IN ACCORDANCE WITH ARTICLE 250 -146 OF NEC AND AS INDICATED IN THE GROUNDING SECTION OF THIS SPECIFICATION. IDENTIFICATION A. BRANCH - CIRCUIT PANELBOARDS: A PHASE COLOR -CODE NAMEPLATE SHALL BE MOUNTED ON THE INSIDE TRIM ADJACENT TO THE MANUFACTURER'S NAMEPLATE. REFER TO WIRE & CABLE SECTION FOR PROPER COLOR CODE FOR VOLTAGE UTIUZED. B. ALL RECEPTACLES, OUTLETS & JUNCTION BOXES SHALL BE LABELED INDICATING PANEL & CIRCUIT NUMBERS. GROUNDING A. ALL FEEDERS AND BRANCH CIRCUITS OVER 100 VOLTS SHALL INCLUDE A GROUNDING CONDUCTOR SIZED IN ACCORDANCE WITH NEC TABLE 250 -122, EXCEPT NOT BE SMALLER THAN #10 FOR POWER AND UGHTING CIRCUITS AND #14 FOR CONTROL CIRCUITS. ALL GROUND CONDUCTORS SHALL BE GREEN, OR AS SPECIFIED UNDER SECTION, "WIRE AND CABLE ". B. AT EACH RECEPTACLE BOX, THE GROUND CONDUCTOR SHALL ENTER AND CONNECT, WITH NORMAL WIRING CONNECTOR, TO: 1) THE GROUND PIGTAIL TO RECEPTACLE; 2) THE GROUND PIGTAIL TO BOX GROUND SCREW; AND 3) THE OUTGOING GROUND CONDUCTOR TO NEXT DEVICE, IF NOT AT END OF RUN. METAL TO METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. C. CONDUIT SYSTEM SHALL BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS SHALL CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON- CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. WHERE REDUCING WASHERS ARE USED AND WHERE CONCENTRIC OR ECCENTRIC KNOCKOUTS ARE NOT COMPLETELY REMOVED BONDING BUSHINGS SHALL BE REQUIRED. JNTERRUPTION OF SERVICE AND OWNER'S OPERATION A. THE ELECTRICAL CONTRACTOR SHALL ORGANIZE HIS WORK SO THAT THESE ALTERATIONS AND ADDITIONS SHALL CAUSE A MINIMUM OF INTERFERENCE AND DISTURBANCE TO THE OWNER. ARRANGEMENTS SHALL BE MADE WITH THE OWNER AND ENGINEER BEFORE INTERRUPTING SERVICE IN ANY AREA. A WRITTEN DETAILED METHOD OF INTERRUPTION PROCEDURE INDICATING ELAPSED TIME REQUIRED AND TIME OF INTERRUPTION SHALL BE PREPARED BY THE ELECTRICAL CONTRACTOR AND SUBMITTED TO THE OWNER FOR APPROVAL. B. ALL INTERRUPTIONS OF SERVICE SHALL BE MADE WHEN THE LOAD IS AT A MINIMUM AND SHALL BE SCHEDULED AT THE OWNER'S CONVENIENCE. (SERVICE INTERRUPTIONS WILL BE SCHEDULED FOR OTHER THAN NORMAL DAYTIME WORKING HOURS. THE ELECTRICAL CONTRACTOR SHALL INCLUDE NECESSARY COST FOR OVERTIME LABOR IN ALL BIDS.) C. AT NO TIME SHALL THE ELECTRICAL CONTRACTOR OR HIS EMPLOYEES NORMALLY WORKING ON THE PROJECT LEAVE THE FACILITY DURING A TIME WHEN ANY NORMALLY UVE CIRCUITS OR FEEDERS ARE DISCONNECTED, WITHOUT PERMISSION OF THE ENGINEER. D. ALL MATERIALS, CONNECTIONS AND EQUIPMENT FOR TEMPORARY CONTROL OR POWER WIRING TO MAINTAIN CONTINUITY OF SERVICE DURING CONSTRUCTION SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. ALL LOADS NORMALLY SUPPLIED FROM THE ELECTRIC UTILITY AND THOSE SUPPUED FROM THE OWNER'S ENGINE GENERATORS ARE INCLUDED IN THE ABOVE PARAGRAPH. FIRE ALARM A. SCOPE B. D. 1. PROVIDE NEW DEVICES AS NEW ZONES AS REQUIRED. 2. REPROGRAM THE EXISTING NEW DEVICES, INTERLOCKS SYSTEM. STANDARDS SHOWN ON THE DRAWINGS. WIRE THE NEW DEVICES TO NEW DEVICES SHALL MATCH EXISTING DEVICES. SYSTEM (INCLUDING GRAPHIC DISPLAYS) TO INCLUDE ALL AS REQUIRED TO PROVIDE A COMPLETE OPERATING 1. THE MATERIALS, WIRING AND EQUIPMENT SHALL BE DESIGNED AND BUILT IN ACCORDANCE WITH THE BEST PRACTICES OF THE ELECTRICAL INDUSTRY AND SHALL CONFORM TO THE STANDARDS OF: a. b. c. d. e. NATIONAL ELECTRICAL CODE THE NATIONAL ELECTRICAL SAFETY CODE APPLICABLE STATE AND LOCAL CODES NATIONAL FIRE PROTECTION ASSOCIATION UL LISTED OR ASSOCIATED FACTORY MUTUAL INSURANCE COMPANY USTED 2. EQUIPMENT SHALL MATCH EXISTING SYSTEM. DEVICES 1. STROBES EQUIPMENT MANUFACTURER SHALL SELECT THE INTENSITY RATING FOR EACH VISUAL APPUANCE TO PROVIDE AN EQUIVALENT ILLUMINATION FOR THE SPACE /INSTALLATION TO COMPLY WITH ADA AND NFPA 72. 2. SPEAKER /STROBES EQUIPMENT MANUFACTURER SHALL SELECT THE INTENSITY RATING FOR EACH VISUAL APPUANCE TO PROVIDE AN EQUIVALENT ILLUMINATION FOR THE SPACE /INSTALLATION TO COMPLY WITH ADA AND NFPA 72. PROVIDE TWO (2) SPARE HORN /STROBES FOR INSTALLATION WITHIN AREA OF CONSTRUCTION. 3s& REGttvt.o CITY OF TUKI ': Il A NOV 2 7 2012 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279-1234 STAMP CONSULTANT FIRM NECHAMCAUELECTRICAL EMiNNEERING COMMUNICATIONS ENGNJEERWG CONSULTANTS PHOENIX. K 23?6 y3PiBAcK ROAD PHOOiI. ARNONA 85076 PHOZ34S.741.1 7S923.3a6, COLUMBUS. 6020lA FFE" RENO COMM&OHO 63231 PS14.3 . 02 FM43922907 DitSCRIPTION CenturyLink GEO LOC ID FLOOR aulIILA CYBER - INTERIOR UPGRADES STREET ADDRE S6`5101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 ABBREVIATIONS & GENERAL NOTES [67F"f66 !O. ) ISSUED FOR CITY COMMENTS REVISIONS CONSULTANT NAME NOTICE The information contakfed herein should not be disclosed to unauthorized persons. N is meant for use by authorized rep9esentailves of CenturyLink. No. DESCRIPTION DATE DRAWN BY 0.221 12 1 DELTA 1 11/19/12 DATE CHECKED BY RAR CASE NUMBER 11/1912 JTF FLE,,u„& REVISED BY SCALE N.T.S. JOB NO. 12033 SHEET NO. E -001 This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 BREAK ROOM MEN'S RESTROOM HALLWAY 2 n JANITOR'S CLOSET HALLWAY 1 WOMEN'S RESTROOM STORAGE EQUIPMENT ROOM RECEPTION AREA CONFERENCE ROOM r- 1 1 I1_ I 1 1 L_J SECURITY LOBBY DEMOLITION REFLECTED CEILING PLAN SCALE: 1/4" = 1 BREAK ROOM P MEN'S RESTROOM HALLWAY 2 JANITOR'S CLOSET WOMEN'S RESTROOM HALLWAY 1 STORAGE EQUIPMENT ROOM RECEPTION AREA fi II 11 11 i \ 11 IL CONFERENCE ROOM SECURITY LOBBY 10 DEMOLITION FLOOR PLAN SCALE: 1/4" = 1' -0" SEPARATE PERMITAND APPROVAL REQUIRED 4 GENERAL NOTES 1. 2. ALL EQUIPMENT IS EXISTING TO REMAIN, UNLESS NOTED OTHERWISE. THE LOCATION AND QUANTITY OF EQUIPMENTS /DEVICES SHOWN ARE APPROXIMATE. VERIFY EXACT LOCATION IN FIELD. 3. IF CIRCUff NG SERVING A DEVICE, OR LIGHT FIXTURE, ETC, TO BE REMOVED ALSO SERVES DEVICES TO REMAIN, MAINTAIN AND /OR MODIFY CIRCUIT TO KEEP DEVICES. LIGHTS, ETC IN SERVICE. 4. DURING CONSTRUCTION, ELECTRICAL CONTRACTOR TO PROVIDE SUFFICIENT TEMPORARY LIGHTING IN DEMOLmON /WORK AREA. 5. ELECTRICAL CONTRACTOR IS TO PROPERLY DISPOSE OF LAMPS, BATTERIES, AND BALLASTS. PROVIDE A CERTIFICATE OF PROPER DISPOSAL TO OWNER. LAMPS AND BALLASTS ARE TO BE RECYCLED. 6. ELECTRICAL CONTRACTOR SHALL REPLACE ANY CEILING TILES THAT ARE DAMAGED THROUGHOUT THE CONSTRUCTION OF THE PROJECT. 7. THE EXISTING CONDm0NS SHOWN WERE OBTAINED FROM OWNER PROVIDED RECORD DRAWINGS AND FIELD OBSERVATIONS. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF WORK, IF ANY DISCREPANCIES ARE FOUND, NOTIFY ENGINEER IN WRITING CODED NOTES 0 1. ELECTRICAL CONTRACTOR SHALL DISCONNECT EXISTING SMOKE DETECTOR FROM EXISTING CEIUNG GRID, STORE AND RE- INSTALL IN NEW LOCATION. ELECTRICAL CONTRACTOR SHALL MAKE ALL WIRING SECURE. SEE SHEET E -102 FOR NEW LOCATION. 2. ELECTRICAL CONTRACTOR SHALL REMOVE EXISTING 2'X4' UGHT FIXTURE FROM EXISTING CEILING GRID STORE, AND RE- INSTALL IN NEW LOCATION. ELECTRICAL CONTRACTOR SHALL REMOVE ALL CONDUIT & WIRE BACK TO AN UNSWITCHED POINT OF RECONNECTION. SEE SHEET E -102 FOR NEW LOCATION 3. EXISTING SECURITY CAMERA TO REMAIN. 4. EXISTING UGHT FIXTURE TO REMAIN. 5. EXISTING EXIT LIGHT FIXTURE TO REMAIN. 6. EXISTING CEIUNG MOUNTED SMOKE DETECTOR TO REMAIN. 7. EXISTING IN- BOARD /OUT -BOARD UGHT SWITCH TO REMAIN. ELECTRICAL CONTRACTOR SHALL RE- CONFIGURE EXISTING SWITCH PATTERN. SEE SHEET E -102 FOR NEW SWITCH PATTERN. 8. ELECTRICAL CONTRACTOR SHALL REMOVE EXISTING RECEPTACLE. ELECTRICAL CONTRACTOR SHALL REMOVE ALL EXISTING CONDUIT & WIRE BACK TO A POINT OF RECONNECTION IF THE SYSTEM IS TO BE USED IN THE AREA TO BE REMODELED OR IF IN USE OUTSIDE THE AREA OF REMODEL AND MAKE SECURE. CIRCUITS ARE DEDICATED UPS POWER. SEE SHEET E -102 FOR NEW LOCATION. 9. DEMOLITION WORK BY GENERAL CONTRACTOR. 10. EXISTING FIRE ALARM DEVICE TO REMAIN. 11. EXISTING RECEPTACLE TO REMAIN. 12. ELECTRICAL CONTRACTOR SHALL REMOVE EXISTING ACCESS CONTROL DEVICES ASSOCIATED WITH THIS DOOR AND STORE. SECURITY CONTRACTOR SHALL DISCONNECT ALL WIRING BACK TO SOURCE. 3 s � qt' RECtivED CITY OF TUKWILA NOV 2 7 2012 PFRMIT CENTER KEY P LA N SCALE: N.T.S. MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 STAMP CONSULTANT FIRM MECILAMCAUELECTRICAL ENGINEERRIG COMMUMCAT1ONS EN *4EERING CONSULTANTS PHOENIX. AZ 2576 CAMELRACK ROAD Pt Pl .ARIZ A IIIKR 6 P5167343.7414 EZ0.3432301 Im,uIeus, a1 663O1N1PPER ROAD COLUBUS. OHO 43331 Ps14342.2110¢ PS443922607 ISSUED FOR CONSTRUCTION PERMIT DESCRIPTION CenturyLink GEO LOC ID FLOOR 8UltnitaZILA CYBER - INTERIOR UPGRADES STREETADDREV101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DEMOLITION FLOOR & RCP PLANS REVISIONS CONSULTANT NAME NOTICE The Mfonnetlon contained herein should not be disclosed to unauthorized persons. It Is meant for use by authorized representatives of CenturyLi k. No. DESCRIPTION DATE DRAWN BY RAR DATE 10/12/12 CHECKED BY JTF CASE NUMBER JOB NO. 12033 REVISED BY SCALE 1/4"=1'-0" FILE NAME SHEET NO. E -101 This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 BREAK ROOM BREAK ROOM MEN'S RESTROOM HALLWAY 2 107 MEN'S RESTROOM HALLWAY 2 107 JANITOR'S CLOSET EQUIPMENT ROOM JANITOR'S CLOSET WOMEN'S RESTROOM S.O.C. 101 BYPASS 102 J SECURITY LOBBY 104 106 STORAGE WOMEN'S RESTROOM EQUIPMENT ROOM HALLWAY 1 106 STORAGE S.O.C. 101 M.T. 103 BYPASS 102 CONFERENCE ROOM 105 NEW REFLECTED CEILING PLAN SCALE: 1 /4" = 1'-0" 103 24 CONFERENCE ROOM 105 SECURITY LOBBY 104 NEW FLOOR PLAN SCALE: 1/4" =11-0" GENERAL NOTES 1. EQUIPMENT SHOWN IS EXISTING TO REMAIN UNLESS NOTED OTHERWISE. 2. THE LOCATION AND QUANTITY OF EQUIPMENTS /DEVICES SHOWN ARE APPROXIMATE. VERIFY EXACT LOCATION IN FIELD. 3. THE EXISTING CONDITIONS SHOWN WERE OBTAINED FROM OWNER PROVIDED RECORD DRAWINGS AND FIELD OBSERVATIONS. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF WORK, IF ANY DISCREPANCIES ARE FOUND, NOTIFY ENGINEER IN WRITING. 4. SEE SHEET E -001 FOR TYPICAL DOOR HARDWARE WIRING DETAIL 5. THE BRANCH CIRCUIT IDENTIFICATION SHOWN REPRESENTS THE DESIGN INTENT (QUANTITY AND SIZE OF BRANCH CIRCUIT). THE ELECTRICAL CONTRACTOR SHALL REUSE EXISTING BRANCH CIRCUIT BREAKERS OBTAINED FROM DEMOLITION. 6. THE ELECTRICAL CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO CIRCUIT BREAKER POLE LOCATIONS TO ACCOMMODATE THE CIRCUIT BREAKER TIES. SEPARATE PERMIT AND APPROVAL REQUIRED CODED NOTES 0 1. ELECTRICAL CONTRACTOR SHALL PROVIDE NEW 2'X2' LIGHTING FIXTURE. PROVIDE 2 #12 + #12G IN 3/4 "C AND REUSE EXISTING CIRCUIT OBTAINED FROM DEMOUTION. MAKE ALL FINAL TERMINATIONS. SEE FIXTURE SCHEDULE ON SHEET E -001 FOR ADDITIONAL INFORMATION. 2. ELECTRICAL CONTRACTOR SHALL CLEAN, AND RE- INSTALL EXISTING 2'x4' LIGHT FIXTURE. PROVIDE 2 #12 + #12G IN 3/4 "C AND REUSE EXISTING CIRCUIT OBTAINED FROM DEMOLITION. MAKE ALL FINAL TERMINATIONS. 3. ELECTRICAL CONTRACTOR SHALL PROVIDE NEW EXIT LIGHT FIXTURE. PROVIDE 2 #12 + 112G IN 3/4 "C AND REUSE EXISTING EMERGENCY UGHTING CIRCUIT. MAKE ALL FINAL TERMINATIONS. MAKE ALL FINAL TERMINATIONS. SEE FIXTURE SCHEDULE ON SHEET E -001 FOR ADDff1ONAL INFORMATION. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE NEW SINGLE POLE LIGHT SWITCH. 5. RELOCATED SMOKE DETECTOR NEW LOCATION. ELECTRICAL CONTRACTOR SHALL RE- INSTALL SMOKE DETECTOR, TERMINATE EXISTING I.D.C. WIRING OBTAINED FROM DEMOLITION WORK AND TEST SYSTEM. 6. EXISTING CEILING MOUNTED SMOKE DETECTOR TO REMAIN. 7. ELECTRICAL CONTRACTOR SHALL PROVIDE NEW CEILING MOUNT FIRE ALARM DEVICE TO MATCH EXISTING DEVICES. PROVIDE NEW I.D.C. CABUNG IN 3/4" CONDUIT AND TEST SYSTEM UPON COMPLETION OF FIRE ALARM DEVICE INSTALLATION. 8. EXISTING LIGHT FIXTURE TO REMAIN. ELECTRICAL CONTRACTOR SHALL CLEAN & RE -LAMP LIGHT FIXTURE. 9. EXISTING EXIT LIGHT FIXTURE TO REMAIN. 10. EXISTING SECURITY CAMERA TO REMAIN. 11. ELECTRICAL CONTRACTOR SHALL PROVIDE NEW HORN /STROBE FIRE ALARM DEVICE TO MATCH EXISTING DEVICES. PROVIDE NEW N.A.C. CABLING IN 3/4" CONDUIT AND TEST SYSTEM UPON COMPLETION OF FIRE ALARM DEVICE INSTALLATION. 12. EXISTING FIRE ALARM DEVICE TO REMAIN. 13. NEW CARD READER BY SECURITY CONTRACTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 -GANG JUNCTION BOX WITH SINGLE GANG TRIM RING MOUNTED AT 42" WITH 1" CONDUIT RECESSED IN WALL UP TO ABOVE CEILING AND OUT TO AN ACCESSIBLE LOCATION. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL STRING. 14. NEW SECURITY DESK AND CHECK -IN COUNTER BY GENERAL CONTRACTOR. NO WORK. 15. NEW CAMERA BY SECURITY CONTRACTOR. NO WORK. 16. NEW PUSH BUTTON DOOR RELEASE BY SECURITY CONTRACTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 -GANG JUNCTION BOX WITH SINGLE GANG TRIM RING MOUNTED ON THE UNDERSIDE ON NEW SECURITY DESK AND 1" CONDUIT RECESSED IN WALL TO ABOVE CEIUNG AND OUT TO AN ACCESSIBLE LOCATION IN MAN TRAP 103. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL STRING. 17. NEW PUSH BUTTON DOOR RELEASE BY SECURITY CONTRACTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 -GANG JUNCTION BOX WITH SINGLE GANG TRIM RING MOUNTED ON THE UNDERSIDE ON NEW SECURITY DESK AND 1" CONDUIT RECESSED IN WALL TO ABOVE CEIUNG AND OUT TO AN ACCESSIBLE LOCATION IN HALLWAY 106. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL STRING. 18. NEW PUSH BUTTON DOOR RELEASE BY SECURITY CONTRACTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 -GANG JUNCTION BOX WITH SINGLE GANG TRIM RING MOUNTED AT 42" AFF AND 1" CONDUIT RECESSED IN WALL TO ABOVE CEIUNG AND OUT TO AN ACCESSIBLE LOCATION IN S.O.C. 101. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL STRING. 19. MOTION SENSOR BY SECURITY CONTRACTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 -GANG JUNCTION BOX WITH SINGLE GANG TRIM RING MOUNTED ABOVE ASSOCIATED DOOR WITH 1" CONDUIT RECESSED IN WALL UP TO ABOVE CEIUNG AND OUT TO AN ACCESSIBLE LOCATION. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL STRING. 20. 21. 22. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 -GANG RECESSED MOUNTED JUNCTION BOX AT 18" A.F.F., 1" CONDUIT UP TO 6" ABOVE LAY -IN CEIUNG IN ACCESSIBLE LOCATION, CONDUIT BUSHING. ELECTRICAL CONTRACTOR PROVIDE 2 #12 + #12 GRD IN 3/4 "C FROM NEW RECEPTACLES TO EXISTING DEDICATED UPS POWER CIRCUIT OBTAINED FROM DEMOUTION. MAKE ALL ANAL TERMINATIONS. NEW BIO READER BY SECURITY CONTRACTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 -GANG JUNCTION BOX WffH SINGLE GANG TRIM RING MOUNTED AT 42" WITH 1" CONDUIT RECESSED IN WALL UP TO ABOVE CEIUNG AND OUT TO AN ACCESSIBLE LOCATION. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL STRING. 23. NEW PUSH BUTTON DOOR RELEASE BY SECURITY CONTRACTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 -GANG JUNCTION BOX WITH SINGLE GANG TRIM RING MOUNTED ON THE UNDERSIDE ON NEW SECURITY DESK AND 1" CONDUIT RECESSED IN WALL TO ABOVE CEIUNG AND OUT TO AN ACCESSIBLE LOCATION IN BYPASS 102. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL STRING. 24. ELECTRICAL CONTRACTOR SHALL EXTEND EXISTING 120 VOLT CIRCUIT WITH 2 #12 + #12 GRD IN 3/4 "C TO NEW DUPLEX RECEPTACLE. RECtivEL) MY OF TUKVIIt.A NOV 2 7 2012 PERMIT CENTER KEY PLAN SCALE: N.T.S. MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 CONSULTANT FIRM YECwwICAUELECTRICAL ENGINEERING COMMUNICATIONS ENGINEERING CONSULTANTS PHOENIX. AZ COMBOS OH 2675 GUMS.= ROAD GINO I./OFFER ROAD PHOENIX. ARIZONA 85018 COMMIE OHIO 43231 Py07343.7414 PEN-19229OP Fx9u43.311 P t4.38t.?i07 CenturyLink GEO LOC D FLOOR BuILDI ILA CYBER - INTERIOR UPGRADES STREET 6101 SOUTH 180TH. STREET TUKWILA, WA. 98188 CITY, STATE DESCRIPTION NEW FLOOR & RCP PLANS STAMP O.U. /3 ISSUED FOR CONSTRUCTION PERMIT CONSULTANT NAME REVISIONS NOTICE The kionnatIon contained herein should not be disclosed to unauthorized persons. R is meant for use by authorized representatives of CeMuryLink. No. to. 31 /2.. DESCRIPTION DATE DRAWN BY DATE CHECKED BY RA R CASE NUMBER 10/12/12 JTF FILE NAME REVISED BY SCALE 1/4"=1'-0" JOB NO. 12033 SHEET NO. E -102 This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 MEN'S RESTROOM 111 JANITOR'S CLOSET 110 WOMEN'S RESTROOM 109 HALLWAY 1 106 RECEPTION AREA 101 SECURITY LOBBY 104 7 10 EQUIPMENT ROOM 108 CONFERENCE ROOM DEMOLITION REFLECTED CEILING PLAN 18 MEN'S RESTROOM 111 HALLWAY 2 107 JANITOR'S CLOSET 110 WOMEN'S RESTROOM 109 HALLWAY 1 106 RECEPTION AREA 101 SECURITY LOBBY 104 SCALE: 1/4" = 1' -0" EQUIPMENT ROOM 1 08 CONFERENCE ROOM 105 DEMOLITION FLOOR PLAN SCALE: 1/4" = 1' -0" CODED NOTES 0 1. ELECTRICAL CONTRACTOR SHALL REMOVE EXISTING 2'X4' LIGHT FIXTURE FROM EXISTING CEILING GRID STORE, AND RE- INSTALL IN NEW LOCATION. ELECTRICAL CONTRACTOR SHALL REMOVE ALL CONDUIT & WIRE BACK TO AN UNSWITCHED POINT OF RECONNECTION. SEE SHEET E -104 FOR NEW LOCATION. 2. ELECTRICAL CONTRACTOR SHALL REMOVE EXISTING 2'X2' LIGHT FIXTURE FROM EXISTING CEILING GRID STORE, AND RE- INSTALL IN NEW LOCATION. ELECTRICAL CONTRACTOR SHALL REMOVE ALL CONDUIT & WIRE BACK TO AN UNSWITCHED POINT OF RECONNECTION. SEE SHEET E- 1 04 FOR NEW LOCATION. 3. EXISTING 2'X4' LIGHT FIXTURE TO REMAIN. 4. EXISTING 2'X2' LIGHT FIXTURE TO REMAIN. 5. EXISTING EXIT LIGHT FIXTURE TO REMAIN. 6. ELECTRICAL CONTRACTOR SHALL REMOVE EXISTING IN- BOARD /OUT -BOARD UGHT SWITCH. ELECTRICAL CONTRACTOR SHALL RE- CONFIGURE EXISTING SWITCH PATTERN. SEE SHEET E -104 FOR NEW SWITCH PATTERN.. 7. EXISTING SINGLE POLE UGHT SWITCH TO REMAIN. 8. EXISTING HEAT DETECTOR TO REMAIN. 9. EXISTING HEAT DETECTOR TO BE REMOVED FROM CEIUNG GRID STORE, AND RE- INSTALL IN NEW LOCATION. EXTEND EXISTING WIRE AND CONDUIT TO NEW LOCATION. SEE SHEET E -104 FOR NEW LOCATION. 10. EXISTING SECURITY CAMERA TO REMAIN. 11. EXISTING WALL TO BE REMOVED BY GENERAL CONTRACTOR. 12. ELECTRICAL CONTRACTOR SHALL DISCONNECT EXISTING FIRE ALARM STROBE, STORE AND RE- INSTALL IN NEW LOCATION. REMOVE ALL WIRE AND CONDUIT BACK TO SOURCE. SEE SHEET E -104 FOR NEW LOCATION. 13. ELECTRICAL CONTRACTOR SHALL REMOVE EXISTING WALL MOUNTED MODULAR FURNITURE 8 -WIRE WHIP CONNECTION. TURN WIRE WHIP OVER TO OWNER. PROVIDE NEW COVER PLATE. REMOVE WIRE AND CONDUIT BACK TO A POINT OF RECONNECTION. 14. ELECTRICAL CONTRACTOR SHALL REMOVE EXISTING DUPLEX RECEPTACLE. PROVIDE A NEW COVER PLATE. REMOVE ALL WIRE AND CONDUIT BACK TO A POINT OF RECONNECTION. 15. EXISTING GFI RECEPTACLE ABOVE SINK TO REMAIN. 16. EXISTING FIRE ALARM PULL STATION TO REMAIN. 17. EXISTING FIRE ALARM SPEAKER STROBE TO REMAIN. 18. EXISTING RECEPTACLE TO REMAIN. 19. EXISTING DATA OUTLET TO REMAIN. 20. ELECTRICAL CONTRACTOR SHALL REMOVE EXISTING EXIT LIGHT FIXTURE FROM EXISTING CEILING GRID STORE, AND RE- INSTALL IN NEW LOCATION. ELECTRICAL CONTRACTOR SHALL REMOVE ALL CONDUIT & WIRE BACK TO AN POINT OF RECONNECTION. SEE SHEET E -104 FOR NEW LOCATION. 21. EXISTING SECURITY CAMERA TO BE REMOVED BY SECURITY CONTRACTOR. NO WORK. SEPARATE PERMRANp 4 APPROVAL REQUIRED PANELBOARD PB2B LOCATION GENERAL NOTES 1. THE LOCATION AND QUANTITY OF EQUIPMENTS /DEVICES SHOWN ARE APPROXIMATE. VERIFY EXACT LOCATION IN FIELD. 2. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO TRACE OUT ALL CIRCUITS BACK TO ELECTRICAL PANEL PRIOR TO START OF DEMOLITION WORK. 3. IF CIRCUITING SERVING A DEVICE, OR UGHT FIXTURE, ETC, TO BE REMOVED ALSO SERVES DEVICES TO REMAIN, MAINTAIN AND /OR MODIFY CIRCUIT TO KEEP DEVICES, UGHTS, ETC IN SERVICE. 4. DURING CONSTRUCTION, ELECTRICAL CONTRACTOR TO PROVIDE SUFFICIENT TEMPORARY UGHTING AND POWER IN DEMOLITION /WORK AREA. 5. ELECTRICAL CONTRACTOR SHALL REPLACE ANY CEILING TILES THAT ARE DAMAGED THROUGHOUT THE CONSTRUCTION OF THE PROJECT. 6. ALL ELECTRICAL PANELBOARDS ARE EXISTING TO REMAIN. 7. THE EXISTING CONDITIONS SHOWN WERE OBTAINED FROM OWNER PROVIDED RECORD DRAWINGS AND FIELD OBSERVATIONS. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL EXISTING CONDMONS PRIOR TO START OF WORK, IF ANY DISCREPANCIES ARE FOUND, NOTIFY ENGINEER IN WRITING. boz REGtivLi) CITY OF TUKINIt A NOV 2 7 2012 PERMIT CENTER KEY PLAN SCALE: N.T.S. MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279-1234 STAMP CONSULTANT FIRM ISSUED FOR CONSTRUCTION PERMIT CenturyLink GEO LOC ID FLOOR FIRST BuLDT,ILA CYBER - INTERIOR UPGRADES EEr 101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRIPTION DEMOLITION FLOOR & RCP PLANS REVISIONS CONSULTANT NAME NOTICE The Infomiatlon contained herein should not be disclosed to unauthorized persons. It Is meant for use by authorized representatives of CenturyLink. No. DESCRIPTION DATE DRAWN BY ASR DATE 10/12/12 CASE NUMBER CHECKED BY JTF JOB NO. 12033 REVISED BY SCALE 1/4"=1'-0" FLE NAME SHEET NO. E -103 This drawing is an instrument of service and may not be reproduced or reproductions hereof used without written permission © 2012 BREAK ROOM 112 MEN'S RESTROOM 111 JANITOR'S CLOSET 110 PNL PB2B CKT# 35 PNL PB2B CKT# 26 PNL PB2B CKT# 5 GFI PNL PB2B PNL PB2B CKT# 27 CKT# 29 /BRA } ROOM MEN'S RESTROOM 111 HALLWAY 2 107 0 WOMEN'S RESTROOM 109 HALLWAY 1 106 EQUIPMENT ROOM 108 JANITOR'S CLOSET 110 S.O.C. 101 10 2] ECU RITY LOBBY 1041 103 CONFERENCE ROOM 105 WOMEN'S RESTROOM 109 HALLWAY 1 106 `PNL PB2B CKT# 31 108 PNL PB2B CKT# 33 NEW REFLECTED CEILING PLAN BYPASS 102 101 M.T. 103 SCALE: 1/4" = 1' -0" SECURITY LOBBY 104 CONFERENCE ROOM 105 NEW FLOOR PLAN SCALE: 1/4" = 1' -0" PANEL ID: PB2B VOLTAGE: 208/120V 3$ ,4W LOCATION: MAIN ELEC RM MAIN SIZE: 100A MOUNTING: SURFACE MAIN TYPE: MLO NOTES: - LOAD DESCRIPTION LOAD KVA CIRC BRKR/ POLE CIRC NUMBER CIRC BRKR/ POLE LOAD KVA DESCRIPTION ' air��s1'1,119K A' ' Ai *O e� A �O� 1. 1 * - -2 ! g.� %4 / % /// Lir. / / //. ..7i2 3 - * -4 L ..g1r7 #e12 ���. • �'.I rte. L .aiir A BREAK ROOM RECPT - 20A 1P 5 - - *6 l�'e/ %MOW • �0tar 4� Ar: - i .4 ; 5rAt %O/.Etna 7 * - -8 2.Jl.�7. %4 / % / /.�.- st • A Air 7 - Ag7� r/� 000/ .1.121 11 --*12 C1!j9 r � %� .' ' i����AO �'�. 7. ; Al! 'rem► lire .0ralre X12 13 * - -14 ��''rLM Keg Al • . :• ArarA FA 1175 -* *18 0��00. 0�17,. s001 000 %. ' "'OO� FA AO, r3 4 19 * - -20 Fling MOW � %:1%' e.!�elgt �`�.1%. �Ia�.a'�.J/� Ar Ag ir- .05 00.01 72,21 21 - * -22 ��.L��I �O� CONF RM PROJECTOR .5 20A 1P 23 - - *24 reafrA iO� n�OOi ea :A Oa CONF RM PROJECTOR SCREEN .5 20A 1P 25 * - -26 20A 1P .5 BREAK ROOM RECPT VENDING MACH .5 .5 20A 1P 20A 1P 27 29 -- *30 �� /` //� A. VENDING MACH LOBBY ECPT .6 .5 20A 1P 20A 1 P 31 33 x * -34 re `i i//` / 4 LOBBY TV SCREEN BREAK ROOM DISHWASHER .8 20A 1P 35 - - *36 P%',.rA %e/% 0��00 • • •O! e�. • M i # /AP AO ���// 39 * -40 000`. •; • Ai0iC ci2 41 - - *42 '•1.�� Orow0000. ''000�AA NEW LOAD (CONNECTED): 4.4 KVA NEW LOAD : 12 AMP TOTAL LOAD : 60 AMP ba-c-(4,47 PANELBOARD PB2B LOCATION SEPARATE PERMIT AND APPROVAL REQUIRED KEY PLAN SCALE: N.T.S. GENERAL NOTES 1. ALL UGHTS ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. 2. ELECTRICAL CONTRACTOR SHALL LABEL ALL RECEPTACLES AND UGHTS USING A P -TOUCH LABEL MAKER. LABEL SHALL INCLUDE PANEL AND CIRCUIT NUMBER. 3. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO KEEP A CLEAN WORK AREA AND REPAIR ANY DAMAGE TO WALLS, FLOORING, OR CEILING TILES IN WORK AREA. 4. THE LOCATION OF EQUIPMENT /DEVICES SHOWN ARE APPROXIMATE. VERIFY EXACT LOCATION IN FIELD. 5. AT THE COMPLETION OF WORK, UPDATE ALL ELECTRICAL PANEL'S DIRECTORY /SCHEDULE ON A PRINTED FORM. 6. ALL NEW RECEPTACLE & CONDUIT SHALL BE LABELED. LABEL SHALL INCLUDE BUT NOT UMfTED TO PANEL SOURCE AND CIRCUIT NUMBER. 7. COORDINATE EXACT LOCATION OF NEW RECEPTACLES WITH OWNER PRIOR TO INSTALUNG THE CIRCUITS. 8. ALL PANELBOARDS ARE EXISTING TO REMAIN. 9. THE EXISTING CONDITIONS SHOWN WERE OBTAINED FROM OWNER PROVIDED RECORD DRAWINGS AND FIELD OBSERVATIONS. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF WORK, IF ANY DISCREPANCIES ARE FOUND, NOTIFY ENGI R W:ITI 10. ALL EXISTING LIGHTING EMERGENCY AND NORMAL IS BACKED UP BY AN EMERGENCY GENERATOR. EXISTING EMERGENCY UGHTING HAS A BATTERY BACKUP UNTIL EMERGENCY POWER IS SUPPUED TO THE LIGHT FIXTURES. CODED NOTES 0 1. ELECTRICAL PROVIDE 2 DEMOLITION 2. ELECTRICAL PROVIDE 2 DEMOUTION CONTRACTOR SHALL CLEAN, AND RE- INSTALL #12 + #12G IN 3/4 "C AND REUSE EXISTING . MAKE ALL FINAL TERMINATIONS. CONTRACTOR SHALL CLEAN, AND RE- INSTALL #12 + #12G IN 3/4 "C AND REUSE EXISTING . MAKE ALL FINAL TERMINATIONS.. EXISTING 2'X4' LIGHT FIXTURE. CIRCUIT OBTAINED FROM EXISTING 2'X2' LIGHT FIXTURE. CIRCUIT OBTAINED FROM 3. EXISTING 2'X4' UGHT FIXTURE TO REMAIN. 4. EXISTING 2'X2' UGHT FIXTURE TO REMAIN. 5. EXISTING EXIT LIGHT FIXTURE TO REMAIN. 6. ELECTRICAL CONTRACTOR SHALL PROVIDE NEW SINGLE POLE SWITCH. 7. EXISTING SINGLE POLE UGHT SWITCH TO REMAIN. 8. EXISTING HEAT DETECTOR TO REMAIN. 9. ELECTRICAL CONTRACTOR SHALL RE- INSTALL EXISTING HEAT DETECTOR OBTAINED FROM DEMOLITION IN NEW LOCATION. EXTEND EXISTING WIRE AND CONDUIT TO NEW LOCATION AND TEST SYSTEM UPON COMPLETION OF FIRE ALARM DEVICE INSTALLATION. 10. EXISTING SECURITY CAMERA TO REMAIN. 11. ELECTRICAL CONTRACTOR SHALL RE- INSTALL EXISTING FIRE ALARM SPEAKER STROBE OBTAINED FROM DEMOLITION IN NEW LOCATION. PROVIDE NEW N.A.C. CABLING IN 3/4" CONDUIT AND TEST SYSTEM UPON COMPLETION OF FIRE ALARM DEVICE INSTALLATION. 12. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 #8 + #10 GROUND IN 3/4" CONDUIT FROM PANELBOARD PB2B CIRCUIT #23 TO NEW DUPLEX RECEPTACLE MOUNTED FLUSH IN THE CEIUNG GRID FOR NEW CEILING MOUNTED PROJECTOR. COORDINATE FINAL LOCATION WITH OWNER. MAKE ALL FINAL TERMINATIONS. 13. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 #8 + #10 GROUND IN 3/4" CONDUIT FROM PANELBOARD PB2B CIRCUIT #25 TO NEW MOTORIZED SCREEN JUNCTION BOX MOUNTED ABOVE THE CEIUNG GRID FOR NEW ELECTRONIC SCREEN. NEW ELECTRONIC SCREEN SHALL BE CONTROLLED FROM NEW SWITCH MOUNTED ON WALL COORDINATE FINAL LOCATION WITH OWNER. MAKE ALL FINAL TERMINATIONS. 14. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 -GANG JUNCTION BOX MOUNTED AT 42" A.F.F. ELECTRICAL CONTRACTOR SHALL PROVIDE 3 #12 IN 3/4" CONDUIT FROM NEW JUNCTION BOX TO NEW MOTORIZED SCREEN. MAKE ALL FINAL TERMINATIONS. 15. EXISTING GFI RECEPTACLE ABOVE SINK TO REMAIN. 16. EXISTING ARE ALARM PULL STATION TO REMAIN. 17. EXISTING FIRE ALARM SPEAKER STROBE TO REMAIN. 18. EXISTING RECEPTACLE TO REMAIN. 19. EXISTING DATA OUTLET TO REMAIN. 20. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 #8 + #10 GROUND IN 3/4" CONDUIT APPROXIMATELY 375 FEET FROM DESIGNATED PANELBOARD TO NEW GFI RECEPTACLE MOUNTED ABOVE NEW COUNTER TOPS. COORDINATE FINAL LOCATION WITH OWNER. 21. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 #8 + #10 GROUND IN 3/4" CONDUIT APPROXIMATELY 375 FEET FROM DESIGNATED PANELBOARD TO NEW RECEPTACLE. COORDINATE FINAL LOCATION WITH OWNER. 22. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 #8 + #10 GROUND IN 3/4" FROM RECEPTACLE FOR TV TO CIRCUIT OBTAINED FROM DEMOUTION. MOUNT RECEPTACLE AT CENTER OF NEW N. COORDINATE EXACT MOUNTING HEIGHT WITH OWNER. 23. ELECTRICAL CONTRACTOR SHALL CLEAN, AND RE- INSTALL EXISTING EXIT LIGHT FIXTURE. PROVIDE 2 #12 + #12G IN 3/4 "C AND REUSE EXISTING CIRCUIT OBTAINED FROM DEMOLITION. MAKE ALL FINAL TERMINATIONS. 24. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 #8 + #10 GROUND IN 3/4" CONDUIT FROM NEW GFI RECEPTACLE MOUNTED ABOVE NEW COUNTER TOPS TO EXISTING CIRCUIT OBTAINED FROM DEMOLITION. MAKE ALL FINAL TERMINATIONS. COORDINATE FINAL LOCATION WITH OWNER. 25. NEW DISHWASHER PROVIDED BY OTHERS. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 #8 + #10 GRD IN 3/4 "C APPROXIMATELY 375 FEET FROM DESIGNATED PANELBOARD TO NEW DISHWASHER. MAKE ALL FINAL TERMINATIONS. 26. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 #8 + #10 GROUND IN 3/4" CONDUIT FROM NEW RECEPTACLE TO EXISTING CIRCUIT OBTAINED FROM DEMOUTION. MAKE ALL FINAL TERMINATIONS. COORDINATE FINAL LOCATION WITH OWNER. 27. RELOCATED SECURITY CAMERA BY SECURITY CONTRACTOR. NO WORK. 28. ELECTRICAL CONTRACTOR SHALL PROVIDE 2 -GANG RECESSED MOUNTED JUNCTION BOX AT CENTER OF NEW TV, 1" CONDUIT UP TO 6" ABOVE LAY -IN CEILING IN ACCESSIBLE OCATION AND CONDUIT BUSHING. COORDINATE EXACT MOUNTING HEIGHT WITH 0 N 29. ELECTRICAL CONTRACTOR SHALL CLEAN, AND RE- INSTALL EXISTING 2'X4' EMERGENCY UGHT FIXTURE. PROVIDE 2 #12 + #12G IN 3/4 "C AND REUSE EXISTING CIRCUIT OBTAINED FROM DEMOLITION. MAKE ALL FINAL TERMINATIONS. MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602)279 -1234 CONSULTANT FIRM RhUtl V G1! CITY OF TUKWILA NOV 2 7 2012 PERMIT CENTER GEO LOC D FLOOR FIRST C Butuvi i IILA CYBER - INTERIOR UPGRADES CenturyLmk STREETADDRES&101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRIPTION NEW FLOOR & RCP PLANS STAMP ISSUED FOR CITY COMMENTS REVISIONS CONSULTANT NAME NOTICE The'Moms:Itlon contained herein should not be disclosed to unauthorized persons. It is meant for use by authorized representatives of CenturyIJnk. No. DESCRIPTION DATE DRAWN BY f2 1 DELTA 1 11/19/12 DATE CHECKED BY ASR CASE NUMBER 11/19/12 JTF FILE NAME REVISED BY SCALE 1/4 " =1' -0" JOB NO. 12033 SHEET NO. E -104