Loading...
HomeMy WebLinkAboutPermit D12-376 - CITY OF TUKWILA - SUBURBAN CITIES ASSOCIATION - TENANT IMPROVEMENTSUBURBAN CITIES ASSOCIATION 6300 SOUTHCENTKR BL SUITE 206 D12-376 City AP Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 0003200005 Address: 6300 SOUTHCENTER BL TUKW Suite No: Project Name: SUBURBAN CITIES ASSOCIATION Permit Number: D12-376 Issue Date: 02/15/2013 Permit Expires On: 08/14/2013 Owner: Name: TUKWILA CITY OF Address: 6200 SOUTHCENTER BLVD , TUKVVILA WA 98188 Contact Person: Name: JUDY PETERSON Address: 1011 WESTERN AV, SUITE 706 , SEATTLE WA 98104 Contractor: Name: H S BUILDERS INC Address: 2116 N 120 ST , SEATTLE WA 98133 Contractor License No: HSBUII* 180BG Lender: Name: SELF FUNDED - SUBURBAN CITIES ASSOCIATION Address: Phone: 206 - 587 -0473 Phone: 206 - 367 -8103 Expiration Date: 05/18/2013 DESCRIPTION OF WORK: SMALL TENANT IMPROVEMENT PROJECT REMOVING SECTION OF WALL AND ADDING NEW WALL RESULTING IN THE ADDITION OF 2 EXISTING OFFICES TO SUITE. ONE EXISTING LIGHT WILL BE SHIFTED AND NEW PAINT /CARPET THROUGHOUT. Value of Construction: $10,800.00 Fees Collected: $496.04 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: I -A Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -376 Printed: 02 -15 -2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Storm Drainage: Street Use: Profit: N Water Main Extension: Private: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read an governing this work will be compli N ex• d with Date: Public: Non - Profit: N Public: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not p - • e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: , r-vi S Date: °` 3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D12 -376 Printed: 02 -15 -2013 7: All construction shall be done in confor ce with the approved plans and the requireigiNgs of the International Building Code or International Residential e, International Mechanical Code, WashinggWate Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 min) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 nun). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 25: Aisles leading to required exits shall be provided from all portions of the building and the required width of the doc: IBC -7/10 D12-376 Printed: 02 -15 -2013 aisles shall be unobstructed. (IFC 1013.4) 26: Maintain sprinkler coverage per N.F.P.A. 9 Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 28: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tulcwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 29: An approved manual fire alarm system including audible /visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2328. 30: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2328) 31: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 32: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 34: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 35: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 36: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 37: These plans were reviewed by Inspector 511. If you have any questions, please call Tulcwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -376 Printed: 02 -15 -2013 CITY OF TUKI _ —A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Building Permit No. 1) -- 3"7 4', Project No. Date Application Accepted: t I 30- j Date Application Expires: _ 3U— (3 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 6300 Southcenter Blvd. Tenant Name: Suburban Cities Association King Co Assessor's Tax No.: 000320 -0003 Suite Number: 206 PROPERTY OWNER Name: Judy Peterson Name: City of Tukwila City: Seattle State: WA Zip: 98104 Address: 6300 Southcenter Blvd. Email: jpeterso @heery.com City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Judy Peterson Address: 1011 Western Avenue, Ste. 706 City: Seattle State: WA Zip: 98104 Phone: (206) 587 -0473 Fax: (206) 587 -0469 Email: jpeterso @heery.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Address: Address: 1011 Western Avenue, Ste. 706 City: Seattle State: WA Zip: 98104 Phone: (206) 587 -0473 Fax: (206) 587 -0469 City: State: State: Zip: Phone: Fax: City: State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: H:\Applications \Fonts- Applications On Line \2011 Applications\Pertnit Application Revised - 8- 9- 11.docx Revised: August 2011 bh New Tenant: Floor: 2 ❑ Yes 1,71 „No ARCHITECT OF RECORD Company Name: Heery International Architect Name: Judy Peterson Address: 1011 Western Avenue, Ste. 706 City: Seattle State: WA Zip: 98104 Phone: (206) 587 -0473 Fax: (206) 587 -0469 Email: jpeterso @heery.com ENGINEER OF RECORD Name: SELF FuNLC Company Name: Address: S • C. A Engineer Name: City: State: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: SELF FuNLC -D BY Address: S • C. A City: State: Zip: Page 1 of 4 Valuation of Project (contractor's bid price): $ 10,800 Existing Building Valuation: $ 4,051,800 Describe the scope of work (please provide detailed information): Small tenant improvement project removing section of wall and adding new wall resulting in the addition of 2 existing offices to suite. One existing light will be shifted and new paint /carpet throughout. Will there be new rack storage? ❑.....Yes m.. No If yes, a separate permit and plan submittal will be required. Provide AB Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: m Sprinklers • . ' , . A> towatic Fire Alarm El None ❑ Other (specify) . . . J. J..., • Will there be storage or use of tlatnmable, combustible or hazardous materials in the building? ❑ Yes J No If 'yes', attach list of mdterials•andstorage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications \Forms- Applications On Line \2011 Applications\Permit Application Revised - 8- 9- 11.docx Revised: August 2011 811 Page 2 of 4 Existing Interior Remodel Addition to " Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1s1 Floor 16,615 1 A B 2n0 Floor 16,615 1,306 1 A B 3"' Floor Floors thru Basement 2,030 1 A B Accessory Structure* Attached Garage 14,040 1 A S2 Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: m Sprinklers • . ' , . A> towatic Fire Alarm El None ❑ Other (specify) . . . J. J..., • Will there be storage or use of tlatnmable, combustible or hazardous materials in the building? ❑ Yes J No If 'yes', attach list of mdterials•andstorage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications \Forms- Applications On Line \2011 Applications\Permit Application Revised - 8- 9- 11.docx Revised: August 2011 811 Page 2 of 4 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR Signature: AA O' ZED AGENT: Date: 11/30/2012 Print Name: Judy I. ' eter on Day Telephone: (206) 587 -0473 Mailing Address: 1011 Western Avenue, Ste. 706 Seattle WA 98104 l:\Applications \Forms - Applications On Line \2011 Applications\Pern it Application Revised - 8-9-11 :does: Revised: August 2011 blt City State Zip Page 4 of 4 PUBLIC WORKS PERMIT INFCI'1ATION - 206- 433 -0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District # 125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Septic System: in On -site Septic System — For on -site s . tic system, provide 2 copies of a current septic design approved by King Co y Health Department. ❑ ...Valley View ❑ ... Sewer Availability Provided ❑ .. Highline ❑ .. Renton ❑ .. Renton ❑ .. Seattle Submitted with Application (mark boxe hich apply): ...Civil Plans (Maximum Paper Size — " x 34 ") ❑ ...Technical Information Report (Storm D 'nage) ❑ .. Geotechnical Report ❑ ...Bond ❑ .. Insurance ,\ .. Easement(s) ❑ .. Maintenance Agreement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 h ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way ❑ Non Right -of -way ...Traffic Impact Analysis ..Hold Harmless — (SAO) ...Hold Harness — (ROW) ❑ .. Right -of -way Use • tit for less than 72 hours ❑ .. Right -of -way Us ,: Potential Disturbance ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Work •'`Flood Zone ❑ .. Sty f Drainage ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic ! ` ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire , ne ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection " Irrigation " Domestic Water ❑ ...Permanent Water Meter Size... 7, 0 # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Sewer Main Extension Public I Private ❑ ❑ ...Water Main Extension Publi' ■ Private ❑ FINANCE INFORMATION ❑ ...De ' t Water Meter Size Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ewer ❑ ...Sewage Treatment Monthly Service Billin t Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip 111Applications \Forms - Applications On Line \ 2011 Applications \Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bli Page 3 of 4 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0003200005 Permit Number: D12 -376 Address: 6300 SOUTHCENTER BL TUKW Status: APPROVED Suite No: Applied Date: 11/30/2012 Applicant: SUBURBAN CITIES ASSOCIATION Issue Date: Receipt No.: R13 -00833 Initials: JEM User ID: 1165 Payment Amount: $302.41 Payment Date: 02/15/2013 01:45 PM Balance: $0.00 Payee: KRISTY C BURWELL, SUBURBAN CITIES ASSOC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 05440G ACCOUNT ITEM LIST: Description 302.41 Account Code Current Pmts BUILDING - NONRES 000.322.100 297.90 PLAN CHECK - NONRES 000.345.830 .01 STATE BUILDING SURCHARGE 640.237.114 4.50 Total: $302.41 doc: Receiot -06 Printed: 02 -15 -2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0003200005 Permit Number: D12 -376 Address: 6300 SOUTHCENTER BL TUKW Status: PENDING Suite No: Applied Date: 11/30/2012 Applicant: SUBURBAN CITIES ASSOCIATION Issue Date: Receipt No.: R12 -03226 Payment Amount: $193.63 Initials: WER Payment Date: 11/30/2012 02:35 PM User ID: 1655 Balance: $302.41 Payee: SUBURBAN CITIES ASSOCIATION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 4496 193.63 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 193.63 Total: $193.63 rinr: Rarpint -OR PrintAri• 11- 1n -9n17 INSPECTION RECORD Retain a copy with permit INSPECTION NO. .PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ; (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 6/2 -.3 76 Project: ‘Szi.bzrrb FliN/ �i ri F % Type of Inspection: " !°i Am I. Address: C. 360 St?,/ /' Pa: / et 41Lr Date Called: . Special Instructions: Date Wanted: .m", 2— / 3 p.m. Requester: Phone No: ,9764- 2.2.1 -..s-/3.9 • -- Approved per applicable codes. Corrections required prior to approval. COMMENTS: 74;1 (or yo/ ,/r% ' �" Date me../...... / 7( ..a i ,cJ5-c..f rr . r / ;. s • SPECTION FEE REQUIR D. Priori o next inspec) on :fee.m'ust:ber. at 6300 Southcenter Bt v Suite 100. Call to scheduWeinspection:: •....*. „tip.: • • • r" Y INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 /2 -37� Project: 5 7 /431IR 6 Ad 027 r_�S Type of Inspection: F i7I to /A Jc, - Address: .30 0 56 04/7 C L I/') Date Called; Special Instructions: -S2//k, ZD; 06( ,26a -0/ Date Wanted:. - .2 6.- / 3 p.m: Requester: Phone No: BUG -2 >- 5-/35 Approved per applicable codes. J Corrections required prior to approval. COMMENTS: qlspec r: Date.: Cv— i 3 INSPECTION FEE REQOIRED. Prio to next inspection. fee must be id at 6300 Southcenter BL d.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER • -.77-2-:-T-.1:-I-Zu.:.;-•;43.. e Mrtetif3•44. • INSPECTION RECORD Retain a copy with permit E)/ - 37Ie, PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: t 5-it_14 V 6/1-10 • C. 1 -1- (%-e..5 Type of Inspectiop4.1 • Address: woe) Suite #: a01.47 s 6 /tip Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: -1(f r tU■A-C-- • -- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occupancy Type: • Inspector: a, c„,,,---,— . , Date: it/4/ L3 Hrs.: 1 n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: 1 Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • 4 •.e, • k • "r1 , • • .• •fw •t • •• • • , •• • •• fj. TE PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D12 -376 DATE: 11 -30 -12 PROJECT NAME: SUBURBAN CITIES ASSOCIATION SITE ADDRESS: 6300 SOUTHCENTER BL - SUITE 206 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: MEENTS: 1��`I� Budding Di i on PYibc Wor s K&�tilllti Fire Prevention 1 Structural 11.1 Planning Division ❑I Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -04 -12 Complete Incomplete Not Applicable Comments: Permit'Center:Use Only ;::5;; ~;;; " • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01 -01 -13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit'Center'Use Only CORRECTION LETTER MAILED: Departments issued corrections: e. Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeopleinter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with Li'tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company H S BUILDERS INC 2063678103 2116 N. 120Th St Seattle WA 98133 King Corporation UBI No. 600423576 Status Active License No. HSBUII'180BG License Type Construction Contractor Effective Date 1 /7/1982 Expiration Date 5/18/2013 Suspend Date Specialty 1 General Specialty 2 Unused Business Owner Information Name Role Effective Date Expiration Date LI, JENNIE President 01/07/1982 Bond Amount LI, HIN SING Vice President 01/07/1982 SI7531 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 9 CBIC SI7531 12/14/2010 Until Cancelled $12,000.0009/30 /2010 8 TRAVELERS CAS Et SURETY CO 081S103511679BCM 04/01/2002 Until Cancelled 12/14/2010 $12,000.0004/23 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 26 United Specialty Insurance Com NS1212310 04/11/2012 04/11/2013 $1,000,000.0003 /26/2012 25 United Specialty Insurance Com NS1208873 04/11/2011 04/11/2012 $1,000,000.0003 /18/2011 24 UNITED SPECIALTY INS CO NS1205479 04/11/2010 04/11/2011 $1,000,000.0003 /31/2010 23 UNITED SPECIALTY INS CO 05100743 04/11/2009 04/11/2010 $1,000,000.00 04 /10/2009 22 CENTURY SURETY CO CCP514118 04/11/2008 04/11/2009 $1,000,000.00 04 /11/2008 21 COLONY INS CO GL163721 04/11/2006 04/11/2009 $1,000,000.0004 /09/2008 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 02/15/2013 $$$$$$$$$$$$$$$$$$dgns $$$$$$user$$$$$$ O r OFFICE lI OPEN OFFICE I.T. DEMO 1 FLOOR PLAN NEW WALL TO BE FINISHED/ PAINTED P -1. DEMO PORTION OF WALL AS INDICATED. PATCH EXISTING WALLS TO MATCH ADJOINING FINISH. SEE FINISH PLAN FOR COLOR. CONTRACTOR TO REMOVE AND RECYCLE WHITEBOARt PATCH /PAINT. CONTRACTOR TO COORDINATE PULLING (1) EXIST. TEL. LINE FROM SOUTH WALL IN COPY AREA ABOVE CEILING AND DROP LINE BEHIND COLUMN TO NEW LOCATION. 1/8" = 1, -0" SEISMIC BRACING REQUIRED AT CEILING TO CONSIST OF (2) -12GA. SPLAY WIRES TO STRUCTURE IN OPP. DIRECTIONS AND PERP. TO PARTITION 6'-O" O.C. PRE -PAINT REVEAL GENERAL WALL COLOR. TYP. - 'J' BEAD EA. SIDE W/ JOINT COMPOUND SOUND INSULATION 5/8' TYPE 'X' GWB EA SIDE WALL TYPE MAIN OR CROSS TEE FIRE TREATED WOOD BLOCKING ACOUSTIC CEILING TILE 3 -5/8" CONT. METAL TRACK WITH 114" x 1" BLACK FOAM TAPE BETWEEN TRACK AND BLOCKING FOR SOUND AND LIGHT SEAL 3 -5/8" 20 GA. GALV. STL. STUDS 16 "O.C. - TYP. AT CEILING DETAIL N.T.S. THE VERTICAL STRUT MAY BE EMT CONDUIT, METAL STUDS OR A PROPRIETARY COMPRESSION POST 12 GA. SPLAYED BRACE WIRES CROSS TEE OR LESS ORIESS oii 2" MAX. 1- MINIMUM 314 "(19m AT UNATTACHED WALLS MINIMUM'S 2"(50mm) TYP. SPLAY BRACING DETAIL SUSPENDED CEILING SYSTEM MAXIMUM 8" 202mm)-. WALL LATERAL FORCE BRACING SHALL BE 12' CENTER (MAX.) AND BEGIN NO FATHER THAN 6' FROM WALLS 45° SPLAY WIRE BRACING IN PLANE OF MAIN RUNNER. ALL WIRES ATTACHED TO MAIN RUNNER 4 DIRECTIONS MAIN TEE SPREADER BAR OR OTHER SUITABLE SYSTEM REQUIRED TO KEEP PERIMETER COMPONENTS FROM SPREADING APART MAX. RECOMMENDED LENGTHS FOR VERTICAL STRUTS EMT CONDUIT PIW]^ Ojbaster 112" EMT CONDUIT coffee 3:3( ) I (01 CON, UP TO 6-0" 3/4" EMT CONDUIT U(' TO 8' -6" 1" EMT CONDUIT OF TO 10'-0" 1 METAL STUD l i.-- - ij 71- 1518" METAL STUD (25 GAGE) up TO 6' -2" 2112" METAL STUD (25 GAGE) UP T910' -8° MAXIMUM 3 "(76mm) SEPARATE PERMIT REQUIRED FOR: 14 Mechanical 'l Electrical Plumbing Gas Piping City of Tukwila 4�4 PIN DIVISION LAY -IN CEILING SEISMIC BRACING pTAIL N.T.S. PATCH EXISTING CEILING GRID AND INSTALL NEW TILES IN THIS AREA AFTER DEMO AND LIGHT FIXTURE ARE RELOCATED. RELOCATE EXISTING LIGHT FIXTURE AS INDICATED. DEMO 1 REFLECTED CEILING PLAN 1/8" =1' -0" SOUND INSULATION 3-5/8" 20 GA. GALV. STL. STUDS 16 "O.C. - TYP. ACOUSTICAL SEALANT EA. SIDE - TYP. PLANNING APPROVED No changes can be made to these plans without approval from the Planning Division of DCD Approved By MA l (.7 Date: , 12112 (), A WALL TYPE 6 5/8" TYPE 'X' GWB EACH SIDE -TYP. 3 -5/8" CONT. METAL TRACK RESILIENT BASE CARPET FLOOR SYSTEM AT FLOOR DETAIL GENERAL CONSTRUCTION NOTES 1. GENERAL NOTES APPLY TO ALL DRAWINGS. 2. A COPY OF THE APPROVED PERMIT DRAWINGS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS 3. ALL WORK CONDUCTED UNDER THIS CONTRACT SHALL CONFORM TO THE APPROVED DRAWINGS AND SPECIFICATIONS, AND TQ ALL APPLICABLE CODES AND ORDINANCES. 4. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR REQUIRED NOTIFICATIONS AND COORDINATION WITH GOVERNING AGENCIES. CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES AND THIRD PARTY CONTRACTORS. 6, THE CONTRACTOR SHALL COORDINATE ALL OPERATIONS WITH BUILDING MANAGEMENT INCLUDING AREAS FOR CONSTRUCTION, DEMOLITION, STAGING, STORAGE, ACCESS TO BUILDING AND FLOOR, TIMING QF WORK, AND RELOCATION OF EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC. 7. CONTRACTOR SHALL COORDINATE ALL DELIVERIES AND BUILDING SYSTEM TESTS WITH BUILDING MANAGEMENT. 8. CONTRACTOR SHALL PROVIDE A MINIMUM OF 72 HOURS NOTICE TO BUILDING MANAGEMENT BEFORE ANY INTERRUPTION IN ELECTRICAL, MECHANICAL, ELEVATOR, SECURITY, OR PLUMBING SERVICES. CONTRACTOR SHALL COORDINATE SUCH INTERRUPTIONS WITH THE BUILDING MANAGEMENT. 9. ANY UNINTENDED DISRUPTION TO EXISTING MECHANICAL, ELECTRICAL, PLUMBING, ELEVATOR OR SECURITY SYSTEMS SHALL BE IMMEDIATELY RESTORED TO FULL OPERATION AT NO COST TO THE OWNER. 10. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY CONSULTANT ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY. 11. BUILI3ING WILL BE OCCUPIED BY OWNER'S TENANTS DURING THE CONSTRUCTION PERIOD. PROTECT ALL PASSERBY, OCCUPANTS, AND VISITORS FROM HARM AND INJURY. CONTRACTOR SHALL INSTALL AND MAINTAIN BARRIERS AS NECESSARY TO PROTECT EXISTING EQUIPMENT, PEOPLE, AND FACILITIES DURING CONSTRUCTION. CONTRACTOR SHALL POST SIGNAGE AS NECESSARY TO REDIRECT PEDESTRIAN TRAFFIC IF NECESSARY TO ENSURE PUBLIC SAFETY. ALL FIRE EXITS MUST REMAIN ACCESSIBLE FOR PUBLIC USE. 1 CONF O r OFFICE a OPEN OFFICE a0i FINISH PLAN 1/8" =1' -0" O 1 1-__.__ --- PIW]^ Ojbaster coffee 3:3( ) I (01 CON, Fe a I?I --- --- l i.-- - ij 71- --- \ L! I 1 .' I - L __.. F11 _.__L____ __ C - __ , - -_ I_ 0 r (: ____ =___.f_. - ` .\ r -' L.f, 0 = - LL_ 3 \ \ / \ , r1 _ ____. (1 0 SEPARATE PERMIT REQUIRED FOR: 14 Mechanical 'l Electrical Plumbing Gas Piping City of Tukwila 4�4 PIN DIVISION LAY -IN CEILING SEISMIC BRACING pTAIL N.T.S. PATCH EXISTING CEILING GRID AND INSTALL NEW TILES IN THIS AREA AFTER DEMO AND LIGHT FIXTURE ARE RELOCATED. RELOCATE EXISTING LIGHT FIXTURE AS INDICATED. DEMO 1 REFLECTED CEILING PLAN 1/8" =1' -0" SOUND INSULATION 3-5/8" 20 GA. GALV. STL. STUDS 16 "O.C. - TYP. ACOUSTICAL SEALANT EA. SIDE - TYP. PLANNING APPROVED No changes can be made to these plans without approval from the Planning Division of DCD Approved By MA l (.7 Date: , 12112 (), A WALL TYPE 6 5/8" TYPE 'X' GWB EACH SIDE -TYP. 3 -5/8" CONT. METAL TRACK RESILIENT BASE CARPET FLOOR SYSTEM AT FLOOR DETAIL GENERAL CONSTRUCTION NOTES 1. GENERAL NOTES APPLY TO ALL DRAWINGS. 2. A COPY OF THE APPROVED PERMIT DRAWINGS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS 3. ALL WORK CONDUCTED UNDER THIS CONTRACT SHALL CONFORM TO THE APPROVED DRAWINGS AND SPECIFICATIONS, AND TQ ALL APPLICABLE CODES AND ORDINANCES. 4. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR REQUIRED NOTIFICATIONS AND COORDINATION WITH GOVERNING AGENCIES. CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES AND THIRD PARTY CONTRACTORS. 6, THE CONTRACTOR SHALL COORDINATE ALL OPERATIONS WITH BUILDING MANAGEMENT INCLUDING AREAS FOR CONSTRUCTION, DEMOLITION, STAGING, STORAGE, ACCESS TO BUILDING AND FLOOR, TIMING QF WORK, AND RELOCATION OF EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC. 7. CONTRACTOR SHALL COORDINATE ALL DELIVERIES AND BUILDING SYSTEM TESTS WITH BUILDING MANAGEMENT. 8. CONTRACTOR SHALL PROVIDE A MINIMUM OF 72 HOURS NOTICE TO BUILDING MANAGEMENT BEFORE ANY INTERRUPTION IN ELECTRICAL, MECHANICAL, ELEVATOR, SECURITY, OR PLUMBING SERVICES. CONTRACTOR SHALL COORDINATE SUCH INTERRUPTIONS WITH THE BUILDING MANAGEMENT. 9. ANY UNINTENDED DISRUPTION TO EXISTING MECHANICAL, ELECTRICAL, PLUMBING, ELEVATOR OR SECURITY SYSTEMS SHALL BE IMMEDIATELY RESTORED TO FULL OPERATION AT NO COST TO THE OWNER. 10. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY CONSULTANT ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY. 11. BUILI3ING WILL BE OCCUPIED BY OWNER'S TENANTS DURING THE CONSTRUCTION PERIOD. PROTECT ALL PASSERBY, OCCUPANTS, AND VISITORS FROM HARM AND INJURY. CONTRACTOR SHALL INSTALL AND MAINTAIN BARRIERS AS NECESSARY TO PROTECT EXISTING EQUIPMENT, PEOPLE, AND FACILITIES DURING CONSTRUCTION. CONTRACTOR SHALL POST SIGNAGE AS NECESSARY TO REDIRECT PEDESTRIAN TRAFFIC IF NECESSARY TO ENSURE PUBLIC SAFETY. ALL FIRE EXITS MUST REMAIN ACCESSIBLE FOR PUBLIC USE. 1 CONF O r OFFICE a OPEN OFFICE a0i FINISH PLAN 1/8" =1' -0" O 1 1-__.__ --- PIW]^ Ojbaster coffee 3:3( ) I (01 CON, Fe a I?I --- --- l i.-- - ij 71- --- \ r-no tr:3 OPEN OFFICE II I.T. L E 0 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 12 2012 . City of ila BUILDING ISION FURNISHINGS PLAN (for reference only) (i__}1 1///„„//7„..:" // ? „7 . , 7?i i/i' /// 7/2/7'4/. / //7 /j / ///',f /i'7' i j/ //' / // /// / / /2/ !!/ • /,/, / /l'/ / /' // /f:// / /,- i 7/ // /, //• / /' 2//// / /r'/ /,//'/, / / / / / /r'/, / / / %/ // //. /!f ///://,://///// 7: / / //;/J4727/5777/9/2 //// ?, '�f / // // //72 `//V/ // // f //r/;// / /, / / / / /r- //r✓I%! / /'/ / / /r// iw/ :// / % / //. / / /1, // i //' /'/ " /, // // , //' . /7/, / / // / / / / /' //, ' r/' /!/,/ //'/ /'//,// 1 / //' // ////////// ; / /` /, / / /// ./ 7) ;' / / / / / / //'' / / / /% // / / / /-, / //, /221/,'/, /,� / / / /. // //!r/ / / / : / / /// ' ///' `? 'r''T/1?/7/11/, /J' // //J / / 2`..///7217 //////// //////./222, /1// /// %, ;%/;'%/,/' ////////.//// / / /// , Z / //' /'/% /%///////////1/////722/ /J / / % / /'/' / /'//2W /, I . -; ;/ ;'r 1 //i //r' % / /,/�J '7,27/727 COMMON PATH OF EGRESS TRAVEL SUITE 206 - 76' •0" SUITE 200 - 82' -0" r T „1 / / ,.' ` 2' I • /4612,2 / 2 /// .7 ' '/ ,;fir% - - j. i 2/2/2/521 // 2 %2 /f/.////: 21 // / // /!/ / /, j 7-/ / / / / /,r / /, //1 'j//i' /'// / //i ///2;,2./.222/2-722/.////////: % ////. ///!,2,/// =/// / // / //'' kN"r / / ///;/ /�- i'%%/ 1 �/,*' i' /./,,2 /; ;! / // ///// /'› / //,/ /l, //J' // J;/// / /// ' / / / ///// / / / // // / / / / //, ' /J / /.// ' //y // /41 rw / / // // i' /// /''/ / /' // //`/ //,%///'/ " ////22/72221/7/7/7V////// / /// /.- ///,//,/ / //J1�r/ /;•/ /'` '/ / / / / //'/ // / / /F%//'%!f f/ri/ /// / / /./ // / / / / /,.J /`J. //i i ///72i/ r'rrr `✓ ri/,! r%'//r/ J////'/// /, /// /;_/f1/; /T //t //' //' /: / /J /i // /, /////!///,,8 /: ,22///.// /J �'//', /r'X :'' %%r/T/% ,�%%// r 7; / / / / / / / / /// / /, / r /////721/227.27/7/1 / / / /// /'.r'/'' /i 2. / //%'f,/'/'r! /, /. / / /. //11:/ /. / / /' // / / / / / / / /' /' /r r/ /; /// ///�U /':/.'/ // /// ; //'/./ //// /'/ /2 :/7Y/22.! ///////////4 I // ////2 r Q -< ////7//////;, '� /f�J i I rd 11 ////://i/,`//2)'' i/ / / = == 1 yx_- / / 'v, /;f/2 ''r /;,,f / / // /'/ //2 ' `/ // %/' / 2.4 /,://;//,/ (p1 /2/2/2/ STE. 200 / /44;4=1___ III__ ////////////7/4/1/7://////////// 1'///, ////7/ /J, r / / % / //�///'// /'// /`7r .'r/`// /f/ </ // // / /'/ // // /'// 2// / /i /// // /////////7222// // '/ /////// ��,{{ } {j{ ////////72:2221/// / / / / //' / /% / / /// PROJECT LOCATION /./ / //// //i /'227 - ;////r j!r Vii'% !`l T '!, J/: /// //J/r'/ / /,•r / // ///f / / // / /, /// f /r',; / /, / / //; �', ,,/ I /, /// //: / / / / / /r/i'/ ` i /; / // -2 v- / l J / f /// /r f%i % ;/ i; . j'/ // / r / / / / / //i f / //' I //2 / / ///•• i //fz//T+r/' /21/21/22, J //7/177, r %rs/ / 4'` L/ /, // ' / /L/l..G /rl / / / / / /// /;/,-///7,/,/,;- ,r //J/ /////////////4/v/// / / '/ / //272/2/1- LIFE SAFETY PLAN 1 PROJECT LOCATION - 2ND FLOOR 1 " =20' -0" 12. EXISTING EQUIPMENT, FACILITES, AND FINISHES DAMAGED DURING CONSTRUCTION ON THIS PROJECT SHALL BE RESTORED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO THE APPROVAL OF THE ARCHITECT, AND AT NO ADDITONAL COST TO TFIE OWNER. EXISTING MATERIALS TO BE REMOVED MAY BE USED FOR PATCHING, WITH APPROVAL OF ARCHITECT. 13. SCOPE OF WORK WILL REQUIRE OPENING SOME EXISTING WALLS AND CEILINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF OPENINGS TO MATCH EXISTING, EXCEPT WHERE OTHERWISE NOTED. 14. SUBSTITUTIONS MUST BE OF THE SAME QUALITY, FINISH AND STYLE AS SPECIFIED PRODUCT. ALL SUBSTITUTIONS MUST BE APPROVED BY THE ARCHITECT PRIOR TO SUBMITTAL OF BID. 15. CONTRACTOR TO CLEAN ALL AREAS OF CONSTRUCTION THOROUGHLY, INCLUDING BLINDS, CARPET, GLAZING, SILLS, AND ELECTRICAL PLATES. 16. DIMENSIONS OF EXISTING STRUCTURES ARE BASED ON ORIGINAL DRAWINGS AND CURSORY FIELD MEASUREMENTS AND ARE SHOWN FOR INFORMATION ONLY. CONTRACTOR SHALL FIELD MEASURE AND VERIFY ALL CONDITIONS PRIOR TO COMMENCING WORK. DO NOT SCALE DRAWINGS. 17. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE FROM FACE OF FINISH. 18. THE ELECTRICAL /DATA COMPONENT TO THE PROJECT IS TO BE ENGINEERED BY THE, ELECTRICAL CONTRACTOR (I.E. DESIGN- BUILD). THE ARCHITECT'S INTENT IS INDICATED IN THESE DRAWINGS. 19. DEMOLITION. THE CONTRACTOR WILL BE RESPONSIBLE FOR SENDING ALL DEMOLITION DEBRIS TO AREA CONSTRUCTION DEBRIS RECYCLERS. A COPY OF ALL RECEIPTS ARE REQUIRED AND SUBMITTED TO OWNER. 20. GC IS RESPONSIBLE FOR VERIFYING THAT ALL METHODS AND MEANS OF CONSTRUCTION AND FINISH APPLICATION SHALL CONFORM TO EACH MANUFACTURER'S WARRANTIES AND INSTRUCTION OF APPLICATION. REVISIONS, No changes shall be made tothe scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal end may include additional plan review fees. PROJECT DATA // / /,///' ///// LIFE SAFETY PLAN PROJECT NAME SUBURBAN CITIES ASSOCIATION TENANT IMPROVEMENT PROJECT PROJECT ADDRESS 6300 SOUTHCENTER BLVD., STE. 206 TUKWILA, WA 98188 000320 -0003 33,795 SF P1Z T SIZE: 1,3065P TAX PARCEL NO. GROSS AREA BUILDING HEIGHT 13 FT STORIES 2 STORIES OCCUPANCY GROUP(S) B - BUSINESS / OFFICE CONSTRUCTION TYPE 1A REINFORCED CONCRETE EXISTING BUILDING LEGAL DESCRIPTION GILLIAM W H -D C # 40 BEG 1336.78 FT W AND 1501.5 FT N OF SE COR OF SEC 23 -23-4 TH E 250 FT TH 5 325.5 FT TO N LN OF CO RD # 622 TH WLY ALG SD N LN TO PT S OF BEG TH N TO BEG LESS CO RD PROPOSED PROJECT DESCRIPTION TENANT IMPROVEMENT FOR SUBURBAN CITIES ASSOC. TO INCLUDE TWO OFFICES FROM NEIGHBOR TENANT. APPLICABLE CODES 2009 SBC AND AMENDMENTS 2008 SEC AND AMENDMENTS 2008 NEC 2009 WA ENERGY CODE 2009 EXIST BLDG CODE 2009 SFC 2009 SMC 2009 UPC LOCATION PLAN SUBURBAN CITIES ASSOCIATION 6300 Southcenter Blvd., Ste. 206 Tukwila, WA 98188 OWNER REP: City of Tukwila 6300 Southcenter Blvd., Ste. 100 Tukwila, WA 98188 Contact: Bob Giberson (e) bob.giberson @tukwilawa.gov TENANT: Suburban Cities Association 6300 Southcenter Blvd„ Ste. 206 Tukwila, WA 98188 Contact: Deana Dawson (e) deanna @suburbancities.org (t) 206.431.2457 (t) 206.433.7170 RECEIVED CITY OF TUKWILA NOV 3 0 2012 PERMIT CENTER ARCHITECT: Heery International, Inc, 1011 Western Avenue, Ste. 706 Seattle, WA 98104 Contact: Judy I. Peterson (e) jpeterso©heery.com (t) 206.587.0473 HEERY Heery International Inc. 1011 Western Avenue, Suite 706, Seattle, WA 98104 206.587.0473 project number 1223600 design SUBURBAN CITIES ASSOCIATION RENOVATION 6300 SOUTHCENTER BLVD., STE. 206 TUKWILA, WA 98188 owner's project number consultants /construction managers 7290 REGISTERED ARC seal /signature c STAT 1/.2-Vacit issued for FOR PERMIT date 11.30.12 item date FILE COPY Permlt No., Wr Play: review approval is su 1 .. M. &p rove O1 constrwctiO SIC v o ation at any adopted code or ordinanc of approved Reid Cop and conditions is acICnowiedg d: By Date: c2• / .13 NOTE: ANY MECHANICAL / ELECTRICAL / FIRE PROTECTION WORK WHICH MAY BE REQUIRED WILL BE DESIGN/BUILD BY THE GENERAL CONTRACTOR. HEERY TO SUBMIT DRAWINGS FOR CONSTRUCTION PERMIT. CONTRACTOR TO PICK UP CONSTRUCTION PERMIT AND OBTAIN ANY ADDITIONAL PERMITS WHICH MAY BE REQUIRED. This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein. Including copyrights. It may only be used in a manner consistent with Heery International Incas rights while Neely International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. 'It may not be used for any other purpose except with ttie express written agreement of, anq compensation to, Heery International Inc. VIWWWWWWWWWIW City Of'i'1,lkwila BUILDING DIVISION 0 4. -0" 8'.O" 18 o. SCALE: 8" 1' -0" PLAN NORTH FLOOR, RC PLAN DETAILS AF -102 key plan sheet title sheet number drawn by JIP checked by INITIALS Copyright 0 2011 by Haery International, Inc. all rights reserved, WHEN PLOTT5D AT FULL SIZE THIS SHEET MEASURES 2046"