Loading...
HomeMy WebLinkAboutPermit D12-387 - SOUTHCENTER SOUTH CORPORATE PARK - BUILDING G - SEISMIC UPGRADESOUTHCENTER SOUTHCORPORATE PARK BLDG G 18260 OLYMPIC AV S D12 -387 City ofkukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206. 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 7888900162 Address: 18260 OLYMPIC AV S TUKW Suite No: Project Name: SOUTHCENTER SOUTH CORPORATE PARK, BLDG G Permit Number: D12-387 Issue Date: 04/30/2013 Permit Expires On: 10/27/2013 Owner: Name: EPROPERTY TAX INC DEPT 207 Address: PO BOX 4900 , SCOTTSDALE AZ 85261 Contact Person: Name: KEITH MOORE Address: 21902 96 AV SE , SNOHOMISH WA 98296 Contractor: Name: ADATTO CONSTRUCTION INC Address: 1314 DENNY WAY 103 , SEATTLE, WA 98109 Contractor License No: ADATTCI108DR Lender: Name: SELF FUNDED - CORNERSTONE REAL ESTATE ADVISORS Address: Phone: 206 - 909 -7808 Phone: 206 - 652 -5300 Expiration Date: 03/08/2014 DESCRIPTION OF WORK: VOLUNTARY SEISMIC UPGRADE OF STRUCTURES TO PROVIDE WALL ANCHORS AT THE PERIMETER OF THE BUILDING FROM THE CONCRETE TILT -UP WALL PANELS TO THE WOOD FRAMED ROOF .AND TO PROVIDE CONTINUITY TIES ACROSS THE ROOF DIAPHRAGM. Value of Construction: $115,000.00 Fees Collected: $2,637.32 Type of Fire Protection: International Building Code Edition: 2009 Type of Construction: Occupancy per IBC: 0025 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12-387 Printed: 04 -30 -2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: kot-3 I hereby certify that I have read and e - d this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied hether specified herein or not. The granting of this permit does not pres e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. (� 1 Signature: / ` - 1' (Z1-' Date: CLIOZ ci` —S Q ' �0 ! 3 Print Name: ( a l a r m This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. doc: IBC -7/10 D12 -387 Printed: 04 -30 -2013 6: All construction shall be done in conforr a with the approved plans and the require of the International Building Code or International Residential , International Mechanical Code, Washingt ate Energy Code. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -387 Printed: 04 -30 -2013 • CITY OF TUKWILA Community Development Department P44lie Works Department Permit pnter 6300 So{tthcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov • Building Permit No. b )-- 337 Project No. Date Application Accepted: ( a Date Application Expires: t— .7-1 3 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION l 92.4,o o S King Co Assessor's Tax No.: 7888900162 Site Address: 18200 -18290 Cascade Avenue South Suite Number: Floor: 1 Tenant Name: Various New Tenant: ❑ Yes EZI ..No PROPERTY OWNER Name: Cornerstone Real Estate Advisors, LLC Address: 2448 Main Street City: Santa Monica State: CA Zip: 90405 CONTACT PERSON — person receiving all project communication Name: Keith Moore Address: 21902 96th Avenue SE City: Snohomish State: WA Zip: 98296 Phone: (206) 909 -7808 Fax: Email: keithccce@msn.com GENERALkCONTRACTOR INFORMATION Company lame: To Be Determined Address: Address: 17655 Mountain View Road Architect Name: Phone: (541) 549 -1331 Fax: City: State: Zip: Phone: Fax: Zip: Phone: Contr Reg No.: Exp Date: Tukwila Business License No.: H:\Applications\Forms- Applications On Line\2011 Applications\Permit Application Revised - 8-9 -1 I.docx Revised: August 2011 bh ARCHITECT OF RECORD Company Name: Cascade Crest Consulting Engineers Company Name: Not Applicable Address: 17655 Mountain View Road Architect Name: Phone: (541) 549 -1331 Fax: Email: cccengr @msn.com Address: J City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Cascade Crest Consulting Engineers Engineer Name: Eugene L. Trahem Address: 17655 Mountain View Road City: Sisters State: OR Zip: 97759 Phone: (541) 549 -1331 Fax: Email: cccengr @msn.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name�Dlone- ne.irsbne E (� TT „ "S Address: l c .. V�id 19 blhld� et, J City: Stal: . ip: Page 1 of 4 BUILDING PERMIT INFORMATIONT— 206 -431 -3670 Valuation of Project (contractor's bid price): $ 115,000 Existing Building Valuation: $ 3,951,800 Describe the scope of work (please provide detailed information): Voluntary seismic upgrade of structures to provide wall anchors at the perimeter of the building from the concrete tilt -up wall panels to the wood framed roof and to provide continuity ties across the roof diaphragm. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ® No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None Ill Other (specify) No Changes Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \Applicatnns\Forns- Applications On Line\2011 Apphcanons\Pernul Application Revised - 8- 9- 11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 85,826 0 0 0 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ® No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None Ill Other (specify) No Changes Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \Applicatnns\Forns- Applications On Line\2011 Apphcanons\Pernul Application Revised - 8- 9- 11.docx Revised: August 2011 bh Page 2 of 4 4 PERMIT APPLICATION NOTES — • • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER U ORIZED AGENT: Signature: 677.4.—__ Date: 12/07/2012 Print Name: Keith W. Moore Day Telephone: (206) 909 -7808 Mailing Address: 21902 96th Avenue SE Snohomish WA 98296 city state Zip l Applications\Forne- Applications On Line12011 Applications\Permit Application Revised - 8 -9-1 l.docx Revised: August 2011 6h Page4of4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT ParcelNo.: 7888900162 Permit Number: D12 -387 Address: 18260 OLYMPIC AV S TUKW Status: APPROVED Suite No: Applied Date: 12/07/2012 Applicant: SOUTHCENTER SOUTH CORPORATE PARK, BLDG G Issue Date: Receipt No.: R13 -01475 Payment Amount: $1,600.15 Initials: JEM Payment Date: 04/30/2013 12:59 PM User ID: 1165 Balance: $0.00 Payee: ADATTO CONSTRUCTION, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 263179 1,600.15 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $1,600.15 1,595.65 4.50 doc: Receiot -06 Printed: 04 -30 -2013 City of Tlvilar Department of Community Development 6300 Southcenter Boulevard, Suite 11100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: htm: //www ci_ nrkwila wa. us SET RECEIPT RECEIPT NO: R12 -03276 Initials: User ID: 1655 Payee: CPF KENT VALLEY LLC Payment Date: 12/07/2012 Total Payment: 5,185.85 SET ID: 120712 SET NAME: SEISMIC RETRO SET TRANSACTIONS: Set Member Amount D12 -383 1,037.17 D12 -385 1,037.17 D12 -386 1,037.17 D12 -387 1,037.17 D12 -388 1,037.17 TOTAL: 1,037.17 TRANSACTION LIST: Type Method Description Amount Payment Check 000252 5,185.85 TOTAL: 5,185.85 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 5,185.85 TOTAL: 5,185.85 .ii INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ,i!` (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Dig -387 Project: S.C. cORP82c'iE Ph12k- Type of Inspection: �SiJA t_. Address: V B2. (,c 30.4 AA P el A U Date Called: S � Special Instructions: Date Wanted: 4.In (7_, Z7- 13 p.m. Requester: Phone o: a2o -- Ci 03 -1 3 L/ (. Approved per applicable codes. 1__..J Corrections required prior to approval. COMMENTS: -�� r■ (01t 0 1E4e /i-7: NIA/ 0 Date -27_ , .z.), E SPECTION FEE REQUIRED. Prior to next inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 fp (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 I"' b12- 357 QC) Project: Sotrri -k e. e c tZ , 0012.P0101Th Type of Inspection: ERA ftl J..J t: _1- v S r-1 .7-ru 3k. { 11) ALT- c-- C2) C]-730 n : l _A..- Address: 1 52 O CL4etv1Ple AUS Date Called: Special Instructions: Date Wanted: ( — 20- (3 ,„ p.m. Requester: Phone No: 0.0 G — c, US— 15 `-i (2 ® Approved per applicable codes. Corrections required prior to approval. COMMENTS: CI) AA.N-.14., — Aopr€i J _1- v S r-1 .7-ru 3k. { 11) ALT- c-- C2) C]-730 n : l _A..- - iQic.Nic'L 1. IA If1 I-0H 1 ,J�/ j'2 I x-L -4) rH H o sr •r Insp • r: 'Date: I (- —2 ° -'77 INSPECTION FEE 4EQUIRED. rior to next inspection. fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. MAYES TESTING ENGINEERS, INC. June 25, 2013 City of Tukwila Building Department 6200 South Center Blvd Tukwila, WA 98188 -8188 Attn.: Building Official Re: South Center South Seismic Upgrade Building G 18200 -18290 Olympic Ave South Tukwila, WA Project No. T13050 RECEIVED CITY OF TUKWILA JUN 2?2013 PERMIT CENTER FINAL LETTER Permit: D12 -387 Seattle office 20225 Cedar Valey Road Stit3110 Lyrrmood WA 98036 ph 425.7429360 x425.745.1737 Tacana Office 10029 S. Taaana Vday Stiie E-2 Taccrna,VVA98499 ph 253.584.3720 x253.584.3707 fndOfr,ce 7911 NE 33rd Dri%e Site 190 Poniard, OR 97211 ph 503.281.7515 x503281.7579 This is to inform you that registered special inspections have been completed for this project for Building G as per our reports, copies of which have been sent to you. Special inspection was provided for: • Proprietary Anchors To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to, the city approved drawings, or engineer approved changes. We trust that this provides you with the information that you require. Should you have any questions, give us a call. Sincerely, Mayes Testing Engineers, Inc. Timothy G. Beckerle, P.E. Branch Manager FILE COPY Permit No. STRUCTURAL CALCULATIONS FOR VOLUNTARY PARTIAL SEISMIC UPGRADE SOUTHCENTER SOUTH BLDG G: 18200 - 18290 OLYMPIC AVE SOUTH TUKWILA, WASHINGTON PREPARED FOR: CBRE NOVEMBER 7, 2012 CASCADE CREST CONSULTING ENGINEERS. INC. 17655 MOUNTAIN VIEW ROAD SISTERS, OREGON 97759 (541) 549 -1331 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 17 2012 BUILDING DIVISION PREPARED BY: EUGENE TRAHERN, P.E. bi 387 RECEIVED CITY OF TUKWILA DEC 0 7 2012 PERMIT CENTER So/ TA( 14)4,/,‘/r445/ PAO-77AL_SeYSE aproMpr (I)L4 - 4R4451 /8J93 &scidior Ave- .50,17-f1 D-4 6 - /1390 P4fYiciAlf Aver Sot49-N BLDG 14 - reit zoi- /8281 L<U-Yelgt.4 AVuTH S-th I - 5-4/0: 5evdrif L1i V7Aezi- 23,4,,Da r II - /6354(9 '44)544.6e* A ve AtArg 77-.itt147 PA.0,TEr-T its .461170400 7t.> Sr-iejtwt$7tAre.oci 7.644" .5'&74/11/d 4e-o14 /RA7)4 ae7WEEke 7-/Ye- er0A./e,ed-76-- 77/1-.7-.-cfP e4i)A4.4. PA.4er4,S A leVi3 1.--;Ve"- 12,441E. L/2.61.5 1oo,'01) kotot.5 1/AP14-14Ais Atgove- ij,s rez 3..ciitz_b2A/44, are- Cr2704 473 I 2009 :71 362 c1:7,i eaS4 ez.:Asa Sos 7 0, 9 I I SIN A. a 4/163 6(,/464 . • i.' itS-DS 1: os 3. r•s3 dar 92. d z Bi3 Ce/Li) —, )45c6-- 3 64. VW) 04)9 .Z.e5f8 644Prog;AZ) • /4400 /APO. i 75,0 or Z84 Fog_de-4 evve)-4-62/ • 8 srp - 8 V492.4)6140, 0,t7644) )e, 9S- L C.A9 CAD II OMIT Comuurtmo ENGINEERS. bac. PROJECT gema,r-si-e-avrt92- 6:13,jtriff ENGR: 7--4;4A6a-4* DATE: /0/9b.- SCALE: SHEET Conterminous 48 States 2009 International Building Code Latitude = 47.436 Longitude = - 122.249 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 1.382 (Ss, Site Class B) 1.0 0.472 (S1, Site Class B) Conterminous 48 States 2009 International Building Code Latitude = 47.436 Longitude = - 122.249 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 = Fv x S1 Site Class D - Fa = 1.0 ,Fv = 1.528 Period Sa (sec) (g) 0.2 1.382 (SMs, Site Class D) 1.0 0.721 (SM1, Site Class D) Conterminous 48 States 2009 International Building Code Latitude = 47.436 Longitude = - 122.249 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 =2/3xSM1 Site Class D - Fa = 1.0 ,Fv = 1.528 Period Sa (sec) (g) 0.2 0.921 (SDs, Site Class D) 1.0 0.481 (SD1, Site Class D) Ef_cG Oc/1---eit ./?)oci.P ./cgid/ornt." Ld. .8404)ed.5 1: P 'XL ie3 o C. 94149/ 4a' .0 45Po. c '44"i2v /sc.,. PAP/44, en •5 7,its l's•sZA_aroiroi) z .2ri_oArA 7 '41" 1: '11c7/..i riscciAs RoAciF .1g:*-zr---oriA444/415:s - 21.1).4 4 6LD4 g? 1-0 7 P•sivart_s 26'? paehsiefre72. = 45151 s LL Caoc.te.S.) 41 Ai' 3 ZIL ; 11418 = A 631_4Mo elJ* bL9 alts" , • 7 fdr- zi 4. 3 49z ID iisott-J = 7 Sre-itirr_ zsrAy. 574(.0 Fr a6c4a) CiLscAns Clatir4 Consuuroaa ENGINEERS. tram PROJECT: ''ot.ePliCErafte72. 5-eLrrof ENG R: 6"; 7124 *Sad' DATE: SCALE: 3/ SHEET •• iLL AAt • .5-fdoPs1it4tAIS Vi2c 7r/i/PACAJOE-ds F 4 = 5_!iere3 ST/ = 3. <bc pdiAJez...1 = 1.4ig. t - 54 lAt;v6rio -* 2reas.4--. I 1.c14. &erSI. «v (5.7a,7-4"*../ ,040.1 4,o ic 4 dAz gesiA9 t#4f Aft2P-Pler • .4Teeirr/V6 3x S. Etlfical.,/fair arti 4J.3.fr JL72V P P tiYojadig. i4e74.(116K • P4is 441 6 etc 7V4ApJega t2,14AJig-s Aj z ag gdert 4i61331‘- ` ie 11-51117) CASA z • ei‘r..E. Wtc..6/: gra_awar 04 liort -i56 ii3 0 0051 1 EA :-.' irzr psi 1 7.74.4risa g- !VC, 1.«, 2Y soo 4Bike &AA o xi, v _3 SV, 8 le.: .■,,,k V-IPS'IS = VIA14,0 AzAK Aef ! 6I-it$1410- /a liF) i, 11,454,0 sia)!Y9 164.4 2,23 = i /pia 164:30 , t VP ti A$ i()'4'1 CASCADH CRT CoNsuientaa Epiclotenats. INC. PROJEcT: -5c5c.frgc2EVIVIZ 5¢2c.frfi ENGR: 77e4 gezdr2A, DATE: Ac/9•4 2- SCALE: 1/ SHEET AivehiPA- ft)ic-.:: 731) SeeliP4,140_61 rid ‘211. Lz4Z40 Ce`lectO 3!3_1(v., 2ks Ci A40 „ Ay, r4off d 1 0 .414- .1.76".0 iL61-119 41V, Pt.12.tti 44,151. scglecA t _elope/ rh;/ 0Y/Cif_ T:Y. . Mrs. f 1 i , , 1 9'4I 1L#'1 toriezimiol44fitePI P--*I4P4/ e/./.1,, c 13 AS sci840494 If40,-1414,416zi ektt4o sk" , t 21461 1 2414 f41E-A4. ,Q4!'1 54B44 aN4triitt (26-74 4 7 sfed aver (1=4/21.3 k 64. 67.1!ir Aha...e.VG 444).+_141 e.11 1(0.z0) 1 7;*LIfe.aB /10 r.A0 ...=rz/9sra3 ra_ife,4„1:, 8, is3S-43 toitbui- gassi-8 ram eatra 1/410a 1 .46z413/7541/4.4 1 t AL 161,4 s9 seu+.c °elk-4 car Sti4ez4 i_e89.pare -4-ely • Va9 a/0Fr -zles Aeoss. el) - /63 WeiAt413,rs51: Z 92 i. Q EL:Y._LPAOsfr,-. rsl°4131fg-e86- 1‘ TY( 20,44ret. , I . L Bily$6pPor 0 28Alcs4954V 774--4 A‘goss .2,1.1j46,-)C2 PoR- 711 °PA Atel- 3(3)/i(01) *c Aloof mat& CASCADE( CREST CI:INSULTING ENCUMERS. INC. PROJECT: tfT1+0 Erk#02 Sear4 ENGR: 744 hiega."/ DATE: ,o/9/'2. SCALE: ij SHEET dse- 32-' 6..,!D .LMA..SO 4 4:B/At (1t _ f :Ernie 44taci.si /Q iJ 1?EPr.±E "i7g4 s r 774— Aoecei V7 w -' c9 _ .... .. ;TlE RettO ..c.4ass Pci tQ4/'/S a$ av Lefrr i716 Ai' g±44.1.4erj R it slVc p,-. C a'i = 'YZr3k C-344416c-x 4.23 -40-= - r *2 f , stNks(sicr`', 215,44. 6 fi £ G T/e5 /!`! test" DNS CASCADE CREHT Comm: rpm Views. bac. PROJECT: Smv eeRl Svtr •s4 ENGR: E', /Ki4 2 f DATE: /0 /9 //z. SCALE: SHEET slVc p,-. C a'i = 'YZr3k C-344416c-x 4.23 -40-= - r *2 f , stNks(sicr`', 215,44. 6 fi £ G T/e5 /!`! test" DNS CASCADE CREHT Comm: rpm Views. bac. PROJECT: Smv eeRl Svtr •s4 ENGR: E', /Ki4 2 f DATE: /0 /9 //z. SCALE: SHEET 1.13HS :31VOS :31Va 47 :210N3 #405 -23tAirtaPP-Log.c :J1.33r0Eicl -51921314HDP43 orwansmoo masa aavzsvo re)p (!-AEATEXT - cf4.CVAI . 0:417 Jr', /fir ' gZArtiqlelswi, 147f 1-Verrin.7PrO7- zidATWV/Zr 4 Icr"*"777P-5P'44 e9- A pi t iz g :J7327 127...LS IL 71:00' "or/ ..ve fifiyag)A, (-544) .1re 'H4 cr42.9ar 7 korfifoolveuzg .01pr -201Cag, Spr.p 74SP P '4' rnwvi r rkstit Qatiortiv Asrpoohe 1 2/4 At CI*156 N314010 rtie; ropy* 3(00"061 Wl'ir7 .51111 . 5P1.1 nctg cw t )1.5 _-474 5r7,, ef joy 6 -7(1,w 4:14zwy_L 1,40sej„ • Ci-1,41tt, Ir1044.°g ca-/- -P0V-41.v ;• --Ai K" .WGP 4(2LL :OictvgY: czeoK7keTZ. citior Aszi/-r17.$!4 siottirea/Mtel dyers "zip Lziz ; rxbity, mr4r-4..;7 c2-9 9-,es ye 17vcyo iserg in. 4' 4€ 4A44 todo vcr,a • PE CO D C PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -387 DATE: 12- 07 -12__ PROJECT NAME: SOUTHCENTER SOUTH - SEISMIC UPGRADE SITE ADDRESS: 18260 OLYMPIC AV S • • X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter #+_ Revision # After Permit Issued DPARTM sTS: Iu� 1� / _ I ` ang Dion 1 Fire Prevention 0 uWI Pblic Works Structural n Planning Division Permit Coordinator I01 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1)) Incomplete DUE DATE: 12 -11 -12 Not Applicable Comments: permit`Center Use, Only ' INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: n No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01 -08 -13 Approved I I Approved with Conditions Nr Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center• Use'Only .•, CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documentslrouting slip.doc 2 -28 -02 Contractors or Tradespeople Pinter Friendly Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company ADATTO CONSTRUCTION INC 2066525300 1314 Denny Way 103 Seattle WA 981095444 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601154635 Active ADATTCI108DR Construction Contractor 3/19/1990 3/8/2014 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status ADATTCC171JH CONSTRUCTION CONSTRUCTION CO Construction Contractor General Unused 4/8/1983 3/8/1990 Archived Business Owner Information Name Role Effective Date Expiration Date ADATTO, RICHARD President 01/01/1980 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 CBIC SA9863 03/08/2002 Until Cancelled $12,000.0001/29 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 12 Ohio Cas Ins BK050714200 03/08/2013 03/08/2014 $1,000,000.0002 /19/2013 11 WEST AMERICAN INS CO BKW50714200 03/08/2011 03/08/2014 $1,000,000.0002 /19/2013 I https://fortress.wa.gov/lni/bbip/Print.aspx 04/30/2013 General Structural Notes (THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE DRAWINGS.) 1. THIS STRUCTURE DOES NOT CONFORM TO PRESENT EARTHQUAKE CODE REQUIREMENTS. IT HAS BEEN VOLUNTARILY STRENGTHENED IN ACCORDANCE WITH SECTION 1613 OF THE INTERNATIONAL EXISTING BUILDING CODE (IEBC), 2009 EDITION. 2. THIS PROJECT IS INTENDED TO STRENGTHEN THE OUT -OF -PLANE LOAD PATH BETWEEN THE EXTERIOR CONCRETE TILT-UP WALL PANELS AND THE ROOF DIAPHRAGMS ONLY. THE PROJECT IS A VOLUNTARY PARTIAL SEISMIC UPGRADE AND IS WITHIN CURRENT PRACTICE FOR STRENGTHENING OF EXISTING BUILDINGS OF THIS AGE AND TYPE. ALL ASPECTS OF THE BUILDING ARE NOT INTENDED TO COMPLY WITH CURRENT CODE REQUIREMENTS. THE EARTHQUAKE PERFORMANCE OBJECTIVE OF THE DESIGN IS SUBSTANTIAL LIFE- SAFETY IN ACCORDANCE WITH ASCE -31 "SEISMIC EVALUATION OF EXISTING BUILDINGS ". 3. DESIGN LOADING CRITERIA: OCCUPANCY CATEGORY (IBC TABLE 1604.5) 11 ROOF LIVE LOAD 25 PSF (IS = 1.0) EARTHQUAKE ASCE -31 SS = 1.382, S1 = 0.472, SDS = 0.921, SD1 = 0.481, IE = 1.0, SITE CLASS = D SEISMIC DESIGN CATEGORY D (IBC) 4. ALL NEW MATERIALS, WORKMANSHIP, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2009 EDITION. . CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO .COMMENCING.;; ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE DRAWINGS ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE DRAWINGS, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL: CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. . CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR COMPLETION OF THE WORK. . CONTRACTOR- INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER REPRESENTATIVE AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. . DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE OWNER REPRESENTATIVE AND THE STRUCTURAL ENGINEER. 10. SHOP DRAWINGS FOR STRUCTURAL STEEL AND ENGINEERED WOOD PRODUCTS SHALL BE SUBMITTED TO THE OWNER REPRESENTATIVE AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION OF THESE ITEMS. SHOP DRAWINGS SHALL ALSO BE SUBMITTED TO THE CITY OF TUKWILA BUILDING DEPARTMENT IN ACCORDANCE WITH BUILDING DEPARTMENT REQUIREMENTS AT THE TIME OF CONSTRUCTION. 11. SHOP DRAWING REVIEW: DIMENSIONS AND QUANTITIES ARE NOT REVIEWED BY THE ENGINEER OF RECORD, AND THEREFORE MUST BE VERIFIED BY THE CONTRACTOR. THE CONTRACTOR SHALL REVIEW AND STAMP DRAWINGS PRIOR TO REVIEW BY ENGINEER OF RECORD. SUBMITTALS SHALL INCLUDE A REPRODUCIBLE AND ONE COPY. THE REPRODUCIBLE SHALL BE MARKED AND RETURNED. SHOP DRAWING SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS. THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN CONCEPT BY INDICATING WHICH MATERIAL IS INTENDED TO BE FURNISHED AND INSTALLED AND BY DETAILING THE INTENDED FABRICATION AND INSTALLATION METHODS. IF DEVIATIONS, DISCREPANCIES, OR CONFLICTS BETWEEN SHOP DRAWING SUBMITTALS AND THE CONTRACT DOCUMENTS ARE DISCOVERED EITHER PRIOR TO OR AFTER SHOP DRAWING SUBMITTALS ARE PROCESSED BY THE ENGINEER, THE DESIGN DRAWINGS AND SPECIFICATIONS SHALL CONTROL AND SHALL BE FOLLOWED. SPECIAL INSPECTIONS: 12. STATEMENT OF SPECIAL INSPECTIONS STRUCTURAL ITEMS (SEISMIC DESIGN CATEGORY D): DEFINITIONS: THE SEISMIC LATERAL FORCE- RESISTING SYSTEMS FOR THIS STRUCTURE CONSISTS PRIMARILY OF THE EXISTING CONCRETE WALL PANELS AND THE WOOD FRAMED ROOF DIAPHRAGMS INDICATED ON THE DRAWINGS. SPECIAL INSPECTIONS AND TESTING SHALL BE PERFORMED BY THE OWNER APPOINTED INSPECTION AGENCY IN ACCORDANCE WITH CHAPTER 17 OF THE IBC WITH REPORTS PER IBC SECTION 1704.1.2 SUBMITTED TO THE OWNER, OWNER REPRESENTATIVE, STRUCTURAL ENGINEER, CONTRACTOR, AND BUILDING OFFICIAL FOR EACH DAY SPECIAL INSPECTIONS OR TESTING IS PERFORMED. THESE INSPECTIONS ARE IN ADDITION TO THE INSPECTIONS SPECIFIED IN IBC SECTION 110. SEE TABLES BELOW FOR ADDITIONAL INFORMATION. STRUCTURAL ITEMS WOOD FASTENERS. BOLTS. STRAPS }IOLDOWNS. ETC. EPDXY GROUTED RODS OR REBAR SPECIAL INSPECTION FREQUENCY IBC REFERENCE PERIODIC FOR CONNECTIONS OF ALL MEMBERS OF THE SEISMIC AND WIND RESISTING SYSTEM INCLUDING DIAPHRAGMS, SHEAR WALLS, STRUTS, & HOLDOWNS PERIODIC INCLUDING INSPECTION OF EMBEDMENT DEPTH AND HOLE CLEANUNESS PRIOR TO ALL INSTALLATIONS 1707.3 & 1706.2 TABLE 1704.4, ITEM 4 PERIODIC INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON SITE AT TIME INTERVALS NECESSARY TO CONFIRM THAT THE WORK REQUIREING SPECIAL INSPECTION IS IN CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS. STRUCTURAL OBSERVATION PER IBC SECTION 1710 WILL BE PERFORMED BY THE STRUCTURAL ENGINEER -OF- RECORD DURING CONSTRUCTION AT SIGNIFICANT CONSTRUCTION STAGES AND AT COMPLETION OF THE STRUCTURAL SYSTEM. STRUCTURAL OBSERVATION CONSISTS OF VISUAL OBSERVATION FOR GENERAL CONFORMACE TO THE CONSTRUCTION DOCUMENTS AND DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR THE INSPECTIONS REQUIRED BY SECTIONS 108, 1704, OR OTHER SECTIONS OF THE IBC. ANCHORAGE: 13. EPDXY- GROUTED RODS TO CONCRETE SPECIFIED ON THE DRAWINGS SHALL BE GROUTED WITH "SET -XP ADHESIVE" AS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY, INC. INSTALL IN STRICT ACCORDANCE WITH ICC -ES REPORT NO. 2508, INCLUDING MINIMUM EMBEDMENT REQUIREMENTS OR " HIT -RE- 500 -SD" AS MANUFACTURED BY HILTI CORPORATION AND INSTALLED IN STRICT ACCORDANCE WITH ICC -ES REPORT NO. 2322, INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. SUBSTITUTES PROPOSED BY CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH ICC -ES REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. IN ADDmON, SUBSTITUTIONS SHALL MEET ICC -ES ACCEPTANCE CRITERIA AC308. SPECIAL INSPECTION OF EPDXY- GROUTED ANCHOR INSTALLATION IS REQUIRED. NOTIFY ENGINEER IF BOLT LOCATIONS CONFLICT WITH REINFORCING STEEL - DO NOT CUT REINFORCING OR REDUCE EMBEDMENT DEPTHS WITHOUT PRIOR APPROVAL INSTALL IN STRICT ACCORDANCE WITH ICC -ES REPORT NO. 2508 OR 2322 WHERE A TORQUE TEST IS REQUIRED. UNLESS OTHERWISE NOTED, PROVIDE THE FOLLOWING EMBEDMENT DEPTHS FOR ANCHORS AT CONCRETE: 1/2" DIAMETER ROD 4" 5/8" DIAMETER ROD 4" 3/4" DIAMETER ROD 6" 7/8" DIAMETER ROD 6" RENOVATION: 14. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDRIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. DRIWNG, WHERE USED, SHALL NOT CUT EXISTING REINFORCING. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. UNIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF AND 20 PSF AT ROOFS. 15. CONTRACTOR SHALL CHECK FOR DRY ROT, SPLITTING, CHECKING AND EXISTING DAMAGE AT ALL EXISTING WOOD FRAMING MEMBERS IN AREA OF WORK. ALL ROT SHALL BE REMOVED AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS DIRECTED BY THE STRUCTURAL ENGINEER. 16. IF HOLE IN CONCRETE WALL SHOULD COMPLETELY PENETRATE THE WALL, THE CONTRACTOR IS RESPONSIBLE FOR FILLING, PATCHING AND PAINTING THE HOLE TO MATCH EXISTING CONDITIONS. STRUCTURAL STEEL 17. STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHALL BE BASED ON THE LATEST EDITIONS OF THE A.I.S.C. SPECIFICATIONS AND CODES: 1. SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS - ALLOWABLE STRESS AND PLASTIC DESIGN, OR LOAD AND RESISTANCE FACTOR DESIGN SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS. 2. CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES, ADOPTED MARCH 18, 2005. IN REFERENCE TO SECTIONS 3.1.2 AND 4.4.1, THE CONTRACT DOCUMENTS (DESIGN DRAWINGS) SHOW COMPLETE CONNECTION DETAILS FOR ALL MEMBERS EXCEPT THOSE NOTED TO BE DESIGN -BUILD ITEMS. ALTERNATE CONNECTION DETAILS REQUESTED BY THE FABRICATOR SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL VIA A REQUEST FOR INFORMATION (RFI) PRIOR TO COMPLETION OF SHOP DRAWINGS. IN REFERENCE TO SECTION 3.1.6, FABRICATOR SHALL ALSO REVIEW PROJECT SPECIFICATIONS AND OWNER REPRESENTATIVEURAL DRAWINGS TO DETERMINE PAINTING AND GALVANIZING REQUIREMENTS. MEMBERS EMBEDDED IN CONCRETE, MASONRY OR TO RECEIVE SPRAY -ON FIREPROOFING SHALL NOT BE PAINTED. DO NOT PAINT OR GALVANIZE AREAS OF PIECES TO BE FIELD WELDED, OR REMOVE PAINT AND GALVANIZING IN FIELD PRIOR TO WELDING. IN REFERENCE TO SECTION 3.3, IN THE EVENT OF DISCREPANCIES BETWEEN DESIGN DRAWINGS AND SPECIFICATIONS, THE DESIGN DRAWINGS GOVERN. IN REFERENCE TO SECTION 4.1, THE FABRICATOR SHALL NOT ASSUME BID PACKAGES CONSTITUTE RELEASING THE DRAWINGS FOR CONSTRUCTION WITHOUT EXPLICIT DIRECTION TO DO SO BY THE OWNER. 18. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: TYPE OF MEMBER ASTM SPECIFICATION Fy A. PLATES, ANGLES, CHANNELS, AND RODS A36 36 KSI B. CONNECTION BOLTS (3/4" ROUND, UON) A307 C. THREADED RODS FOR EPDXY GROUTED CONNECTIONS A36 OR A307 (GRADE C) 36 KSI 19. DIMENSIONAL TOLERANCE FOR STRUCTURAL STEEL MEMBERS SHALL BE PER THE AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES, SECTION 6.4 AND ASTM SPECIFICATION A6. 20. HOLE SIZES IN STEEL MEMBERS FOR CONNECTIONS TO CONCRETE SHALL BE GREATER THAN THE NOMINAL BOLT DIAMETER BY 1/16 FOR CAST -IN -PLACE ANCHOR BOLTS, 1/16" FOR EXPANSION BOLTS, AND 1/8" FOR EPDXY GROUTED BOLTS. USE OF LARGER HOLES WOULD REQUIRE THE USE OF WELDED PLATE WASHERS AND WOULD REQUIRE PRIOR APPROVAL BY THE STRUCTURAL ENGINEER. FOR EPDXY GROUTED INSTALLATIONS, GAPS BETWEEN BOLTS AND HOLES IN STEEL MEMBER SHALL BE FILLED SOLID WITH EPDXY PRIOR TO NUT AND WASHER INSTALLATION. 21. ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.S.C. AND A.W.S. STANDARDS AND SHALL BE PERFORMED BY W.A.B.O. CERTIFIED WELDERS USING E70XX ELECTRODES. ONLY PREQUAUFED WELDS (AS DEFINED BY A.W.S.) SHALL BE USED. DO NOT PAINT OR GALVANIZE AREAS OF PIECES TO BE FIELD WELDED, OR REMOVE PAINT AND GALVANIZING IN FIELD PRIOR TO WELDING. 22. NO FIELD WELDING PERMITTED WITHOUT WRITTEN APPROVAL OF THE OWNERS REPRESENTATIVE. WOOD: 23. FRAMING LUMBER SHALL BE KILN DRIED OR MC -19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS: (2x MEMBERS) HEM -FIR NO. 1 MINIMUM BASIC DESIGN STRESS, Fb = 975 PSI, Fv = 150 PSI (3x AND 4x MEMBERS) HEM -FIR NO. 1 MINIMUM BASIC DESIGN STRESS, Fb = 975 PSI, Fv = 150 PSI 24. ENGINEERED LUMBER: EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE NAME AND PLANT NUMBER OF THE MANUFACTURER, THE GRADE, THE NER OR ICC -ES REPORT NUMBER, AND THE QUALITY CONTROL AGENCY. ALL MEMBERS SHALL BE MANUFACTURED WITH AN APPROVED ADHESIVE. PARALAM LUMBER (PSL): Fb = 2,900 PSI, E = 2,000 KSI, Fy = 290 PSI MICROLAM LUMBER (LVL): Fb = 2,600 PSI, E = 1,900 KSI, Fv = 285 PSI 25. ALL PRESSURE- TREATED (P.T.) WOOD MEMBERS SPECIFIED ON THE DRAWINGS THAT OCCUR ABOVE GROUND AND CONTINUOUSLY PROTECTED FROM MOISTURE (INTERIOR LOCATIONS) SHALL BE PRESSURE - TREATED WITH DOT SODIUM BORATE (SBX) WITHOUT NaSi02. AT LOCATIONS PERMANENTLY EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND, WOOD MEMBERS SHALL BE PRESSURE- TREATED Wm-i COPPER AZOLE CA -B (HEM -FIR ONLY), OR ALKALINE COPPER QUAT (ACQ -C FOR DOUGLAS -FIR, OR ACQ -D FOR HEM -FIR) PRESERVATIVES UNLESS OTHERWISE NOTED. AMMONIACAL COPPER ZINC ARSENATE (ACZA) PRESERVATIVE, OR OTHER PRESERVATIVES WITH AMMONIA CARRIERS, SHALL NOT BE USED. SEE GENERAL STRUCTURAL NOTES 26 AND 29 FOR MATERIAL REQUIREMENTS OF CONNECTORS AND FASTENERS IN CONTACT WITH PRESSURE - TREATED MEMBERS. 26. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C- 2011. ALTERNATE CONNECTORS CONFORMING TO IBC SECTION 1715 MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER. A CURRENT ICC -ES REPORT AND A UST STATING THE ITEM -FOR -ITEM SUBSTITUTION MUST BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR ANY PROPOSED SUBSTITUTES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ENGINEERING COSTS RELATING TO REVIEW AND /OR RE- DESIGN TO ACCOMMODATE PROPOSED SUBSTITUTIONS. INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, CENTER STRAP ON JOINT AND INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER, WITH EQUAL NUMBER AND SIZE OF FASTENERS IN EACH MEMBER. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. INSTALL WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. ALL TIMBER JOISTS AND MULTIPLE JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "HU" SERIES JOIST HANGERS, UNLESS OTHERWISE NOTED. ALL TIMBER CONNECTORS IN CONTACT WITH PRESSURE - TREATED WOOD THAT USES PRESERVATIVE CHEMICALS OTHER THAN DOT SODIUM BORATE (SBX) WITHOUT NaSi02 SHALL BE MANUFACTURED FROM ZMAX STEEL BY SIMPSON (G185 STEEL PER ASTM A653), OR TYPE 304 OR 316 STAINLESS STEEL ALTERNATIVELY, CONNECTORS CAN BE POST HOT DIP GALVANIZED PER ASTM A123 OR MECHANICALLY GALVANIZED PER ASTM B695, CLASS 55 OR GREATER. STAINLESS STEEL FASTENERS SHALL BE USED WITH STAINLESS STEEL CONNECTORS, AND HOT DIP GALVANIZED FASTENERS PER ASTM A153 SHALL BE USED WITH GALVANIZED CONNECTORS. 27. ALL WOOD DETAILS SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE IBC. • MINIMUM NAILING SHALL CONFORM TO IBC TABLE 2304.9.1 OR CURRENT ICC -ES REPORT NER -272: COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH OWNER REPRESENTATIVE AND STRUCTURAL ENGINEER. INSTALL WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. INSTALLATION OF LAG SCREWS SHALL CONFORM TO 2005 NDS SECTION 11.1.3 AND INSTALLATION OF BOLTS SHALL CONFORM TO NDS SECTION 11.1.2. 28. ALL NAILS SPECIFIED ON THE DRAWINGS WERE DESIGNED TO BE COMMON NAILS. MINIMUM NAIL DIAMETER AND LENGTH SHALL BE AS FOLLOWS: 10d 0.148" X 3" 16d 0.162" X 3-1/2" 29. ALL TIMBER FASTENERS IN CONTACT WITH WOOD TREATED WITH ONE OF THE APPROVED PRESERVATIVE CHEMICALS LISTED IN THE NOTES ABOVE, OTHER THAN DOT SODIUM BORATE (SBX) WITHOUT NaSi02, SHALL BE POST HOT DIP GALVANIZED PER AST M A153. 30. WOOD GLUE SHALL CONSIST OF T -88 STRUCTURAL EPDXY ADHESIVE BY SYSTEM THREE RESINS, INC. INSTALLED PER THE MANUFACTURERS SPECIFICATIONS. ALL SURFACES MUST BE CLEAN AND FREE FROM DEBRIS PRIOR TO APPLICATION. 18 4 PARATE PERMIT REQUIRED FOR: liriieofa t tod CrteCtdcaI linumbino Q�as Milne City of Tukwila BUILDING DIVISION No ohs Is s. EVISIONS I made to the some cf Wo` witho .prior approval of Tukwila Building Division. F� I fl9V tans will require a new plan submittal cn 3 may include additional plan review fees. SITE PLAN N.T.S. FILE permft No. ploy r, ^v1eW approval is subject to errors and omissions. t = of construction documents does not authcta : :; .ljon of any adopted code or ordinance. Receipt t Lpproved Field Copy and conditions is krcowlsdged: By _. Date: 14 G- City Of Tukwila BUILDING DIVISION REVIEWED FOR E COMPLIANCE APPROVED DEC 17 2012 /(1 City of Tukwila BUILDING DIVISION 15 19 SHEET INDEX: S1.1 GENERAL STRUCTURAL NOTES, SITE MAP & SHEET INDEX S2.G1 PARTIAL ROOF FRAMING PLAN - BUILDING G S2.G2 PARTIAL ROOF FRAMING PLAN - BUILDING G S3.1 DETAILS bLl- 87 RECEIVED CITY OF TUKWILA DEC 0 7 2012 PERMIT CENTER 20 U GENERAL STRUCTURAL PROJECT NO. 12- 0038 -04 PERMIT SET REVISIONS : 2 <<<<<.< SHEET NO. 1 OF : 11 DRAWN BY : LMH DATE: 11 /07/2012 COMPU'1ER FILE : SCALE: NONE SHEET NO. 1 OF : 11 DUST. 2x4 O 24 "oc a rn I N m 50' -0" 50' -0" 50' -0" 10' -0" 4/S3.1 ® 8' -0 "oc TYP. a r• N EXIST. 2x4 O 24 "oc 3/S3.1 a N EXIST. GL v �I AT GLB TYP. a 0 I 0 1 a N do 2/S3.1 0 8' -0"oc TYP. ACROSS FIRST (2) PURUNS a N EXIST. 2x4 O 24"oc 10/S3.1 O 16' -0"oc COL LINE F EXIST. GL 10/53.1 O 32' -0"oc COL LINES C TO E do 111 10/S3.1 O 32' -0"oc COL LINES C TO E do do 10/S3.1 , ® 32 -0"oc COL LINES C TO E EXIST. GL EXIST. GL 50' -0" EXIST. GL 50' -0" 1 9/S3.1 TYP. IJNES 2 TO 12 EXIST. GL 580' -0" 50' -0" 50' -0" do do TYP. EXIST. GL II 10/S3.1 0 16' -0 "oc COL LINE B 4/S3.1 > 0 8' -0 "oc TYP. EXIST. GL ❑ III BUILDING G PARTIAL FRAMING PLAN EXIST. GL SCALE: 1/16" = 1' -0" EXIST. GL a sF N a N. a 0 0 u r i1 I N io REVIEWED FOR CODE COMPLIANCE APPROVED DEC 17 2012 City of Tukwila BUILDING DIVISION bP3S7 RECEIVED CITY OF TUKWILA DEC 0 7 2012 PERMIT CENTER rT144 ROOF FRAMING PLAN BUILDING G PROJECT NO. 12- 0038 -04 PERMIT SET REVISIONS : 2 <<<<l< DRAWN BY : LMH DATE: 11/07/2012 COMPUTER FILE : SCALE: NOTED SHEET NO. S2.G1 4 OF : 11 Ld J U d I 50' -0" 50' -0" 50' -0" 50' -0" 30' -0" 3' -0" 4/S3.1 0 8' -0"oc TYP. ii EXIST. GL do do do EXIST. GL EXIST. GL do iii EXIST. GL 10/S3.1 O 16' -0 "oc COL LINE F EXIST. GL 10/S3.1 O 32' -0"oc COL LINES C TO E EXIST. 8 3/4 GL d 10/S3.1 ® 32' -0 "oc COL LINES C TO E do 10/S3.1 , 0 32 -0 "oc COL LINES C TO E — 9/S3.1 TYP. LINES 2 TO 12 DO EXIST. GL i 10/S3.1 > ® 16' -0 "oc COL LINE 8 11' -0" TYP. DO DO EXIST. 8 3/4 GL I W J 2 U 0 4/S3.1 , 8' -0 "oc TYP. BUILDING G PARTIAL FRAMING PLAN SCALE: 1/16" = 1' -0" 11 EXIST. 2x4 0 24 "oc 3/S3.1 GLB TYP. •--- 2/S3.1 0 8' -0 "oc TYP. ACROSS FIRST (2) PURUNS N 0 0 N t N 4/S3.1 > SKEWED, SIM., TYP. REVIEWED FOR CODE PPR NCE OV Q A DEC 17 2012 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 7 2012 PERMIT CENTER L_ O N r-C7 C o Q Q O eL CL c s - Z .. 0 o D Q I- o QU H> ROOF FRAMING PLAN BUILDING G PROJECT NO. 12- 0038 -04 PERMIT SET REVISIONS : DATE: 11 /07/2012 COMPUTER FILE : SCALE: NOTED 0 z <<<<<< DRAWN BY : LMH DATE: 11 /07/2012 COMPUTER FILE : SCALE: NOTED SHEET NO. S2.G2 5 OF : 11 • toIn z 'n • d ii w z a • -0 F 0 3 ON w o xo raCn L- 0 � 2 Hy 0O 0 te a_ o U E F— a5 z< �UCL� W D C CJ =� o U> J PROJECT NO. 12- 0038 -04 PERMIT SET REVISIONS : i<<<<<< DRAWN BY : 1 "oc 11/07/2012 COMPUTER FILE : SCALE: 2x12 0 EXIST. SHEATHING HD3B 0 8' -0 MAX. WO ROD. PLACE ON SAME ROOF SUB- PURLIN AS WALL ANCHOR W/ 2x4 EXIST. TOP R & 2x8 SISTERED TO EXIST. 2x4 W/ 16d NAILS 0 4 "oc STAGGERED & EXIST. ROOF LPT4 0 2' -0 "oc, EXIST. SHEATHING LUS214 -2 EA. END TOP R EXIST. ROOF SHEATHING HD5B PER PLAN EXIST. ROOF SHEATHING w 07/ i •{ c-7-70) . • . • .`. . EXIST. 2x4 • A. z a. d • d 8 z � _s w Lo o a. • a. . d Q , DETAIL 4a. --c EXIST. 4x HOLDOWN ® 8' -0"oc - 2x4 SISTERED W/ 16d NAILS 0 6 oc . _ SCALE: 1 " -1' -0" EXIST. 2x4 �-� — o o f ��. a A -A HD3B HOLDOWN 0 PER PLAN 0 O • . 4 4' -0"oc PER PLAN EXIST. CONCRETE WALL - 2x12 WHERE REQD. PER DETAIL 1 2 DETAIL 2A: HD5B DETAIL 2B: HD9B EXIST. CONCRETE "oc 8 . 16d 0 4 16d " 4 oc It 0 �� �� EXIST. 2x4 LPT4 0 2' -0 "oc EXIST. BEAM PER PLAN _J EXIST. CONCRETE WALL WALL 2x12 2x8 A -A SCALE: 1 " =1' -0" SCALE: 1 " =1' -0" N_ 1 " SCALE: 1 -1 -0 6 NOTCH 2x12 AS REQ'D HD5B HOLDOWN ® 4' -O" PER PLAN 0 HSTR3 EA. SIDE EXIST. EXIST. PURLIN PLAN V EXIST. TRUSS EXIST. ROOF 0 4' -0 "oc SHEATHING c� 0 0 0 q. I C- o 0 0 `-- I I. d- Z o 1 -� HD9B EA. "0 ROD a EXIST. (o 0 0 o 0 0 EXIST. GL BEAM SIDE W/ 2x12 SISTERED 2x4 W/ & 2x8 TO EXIST. 16d NAILS ® A -A `' Z m 2'_O° a <" c' o CONCRETE WALL N $ EXIST. GL ELEVATION I roc STAGERED & "oc �-� - - ---1\q---L I o f :. • . • • ... : LPT4 0 2' -0 I EXIST. TRUSS -0 "oc d . . � • c a • a EXIST. CONCRETE WALL �' : - - - d • a o a I ® 4' 16d 0 4 "oc �� m=\ EXIST. 2x4 NOT -Y - -- --.� 16d ®4 "oc `` l� ���� `II � N LPT4 2 -0 oc 1. WHERE EXIST. ANCHOR HTT4 W/ (18)10d IS LOCATED, MOVE TO NAILS 0 4' -0 "oc OPP. SIDE OF TRUSS. PER PLAN 2. DETAIL 8A: USE HTT4 ADDED NUT ON WALL EA. SIDE 0 8' -0 "oc SIDE OF HOLDOWN ---- -� EXIST. GL N- '- N 9 SCALE 1 1 0 - - 2x12 11 2x8 A —A SCALE. 1 N =1' -D" 8& 8A PLAN 0 SCALE: 1 " =1' -0" 7 " " SCALE: 1 =1 -0 11 12 HD3B EA. SIDE (4 REQD.) ® 24'oc EXIST. ROOF SHEATHING o " I :I: o 0 • • --->. • / EXIST. 2x4 ® 4' -0 "oc ST2115 W/ (10) 16d NAILS EXIST. TRUSS o I o 2x8 4' SISTERED SCALE 1 " =1' -0" 1 5 x -O" TO EA. SIDE OF TRUSS W/ 16d NAILS 0 roc SCALE: 1"=1'-0* 1 16 17 18 HOLDOWN SCHEDULE REVIEWED FOR CODE COMPLIANCE APPROVED 1 DEC 7 . City Of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 7 2012 HOLDOWN WOOD CONNECTION WALL ANCHOR CONTINUITY TIE ALTERNATE CONNECTION2 HD3B (2) 5/8" DIA. 5/8" DIA. (EMBED 4 ") 5/8" DIA. T2 -24 PAIRED HD5B (2) 3/4" DIA. 5/8" DIA. (EMBED 4 ") 5/8" DIA. T2 -24 PAIRED HD7B (3) 3/4" DIA. 7/8" DIA. (EMBED 6 ") 7/8" DIA. T2 -44 PAIRED HD9B (3) 3/4" DIA. 7/8" DIA. (EMBED 6 ") 7/8" DIA. T2 -44 PAIRED HTT4 (18) 10d NAILS 5/8" DIA. (EMBED 4 ") 5/8" DIA. T2 -24 PAIRED HCSTR3 _ _ (3)3/84" DIA. EA. SIDE T2 -46 PAIRED NOTE: PERMIT CENTER 1. WALL ANCHOR MAY BE EPDXY GROUTED PER GENERAL NOTES. 2. ZONE FOUR HARDWARE i)........ 3 6 7 20 • toIn z 'n • d ii w z a • -0 F 0 3 ON w o xo raCn L- 0 � 2 Hy 0O 0 te a_ o U E F— a5 z< �UCL� W D C CJ =� o U> J PROJECT NO. 12- 0038 -04 PERMIT SET REVISIONS : i<<<<<< SHEET NO. S3.1 11 OF : 11 DRAWN BY : LMH DATE: 11/07/2012 COMPUTER FILE : SCALE: NOTED SHEET NO. S3.1 11 OF : 11