Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D12-392 - STETSON RESIDENCE - WALL DEMOLITION
STETSON RESIDENCE 15278 SUNWOOD BL UNIT C-32 D12 -392 n Dep ar tmentof Comm uni t De Development (*Tukwila 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 8141400580 Address: 15278 SUNWOOD BL TUKW Suite No: Project Name: STETSON RESIDENCE 1 DEVELOPMENT PERMIT Permit Number: D12 -392 Issue Date: 01/14/2013 Permit Expires On: 07/13/2013 Owner: Name: STETSON KATHRYN A +JOHN B II Address: 15278 SUNWOOD BLVD #C -32 , TUKW LA WA 98188 Contact Person: Name: KATHRYN A STETSON Address: 15278 SUNWOOD BL, #C32 , TUKWILA WA 98188 Contractor: Name: BLUE MOOSE HOME SERVICES LLC Address: 817 S 314 ST , FEDERAL WAY WA 98003 Contractor License No: BLUEMMH898ME Lender: Name: Address: Phone: 206 851 -4336 Phone: 253 945 -1394 Expiration Date: 07/05/2013 DESCRIPTION OF WORK: REMOVE WALL BETWEEN KITCHEN AND DINING ROOM AND REPLACE WITH BEAM. Value of Construction: $10,000.00 Fees Collected: $464.52 Type of Fire Protection: SMOKE DETECTORS International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 0022 Electrical Service Provided by: * *continued on next page ** doc: IBC -7/10 D12 -392 Printed: 01 -14 -2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: o��l�l�l3 I hereby certify that I have read and e - d this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied hether specified herein or not. The granting of this permit does not pres a to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: �attit/Utlill Date: /-/ Li-/3 Print Name: u!.('f` V I 9 k, 4 • This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). doc: IBC -7/10 D12 -392 Printed: 01 -14 -2013 7: All electrical work shall be inspected i pproved under a separate permit issued b City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12-392 Printed: 01 -14 -2013 CITY OF TUK!"`LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Building P tit No. 1 ' Project No, Date Application Accepted: h P°- Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: 152 -i8 SUv1WC>Dd 81Vd) EG3� Ka.41■Nrh S4 +sov■ King Co Assessor's Tax No.: t 11-k Q V Suite Number: C 3 L Floor: 3 PROPERTY OWNER Name: owlntr Address: City: State: Zip: Name: KailAn it A. S4fSovt Architect Name: Address: 15)18 SUhwood 6tjc(1 1 ? 2. City: rU{CWIIa., State: wA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: owlntr Address: City: State: Zip: Phone:aO , S 1_4331 Fax: Email: k c t Th q . S f e - I - s c m C " a v h a i I• CO vv>, GENERAL CONTRACTOR INFORMATION Company Name: Address: Company Name: Address: Architect Name: City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H: \Applications \Forms - Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh New Tenant: ❑ Yes jK.. No ARCHITECT OF RECORD Name: Address: Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATIO206- 431 -3670 Valuation of Project (contractor's bid price): $ /°/ OUP, 00 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): re VIA OVe w all be �w eevt k i+ Ch e vl d 1 v< i h9 roo wx , re-p (ace. w i +ti beam ) Will there be new rack storage? ❑ ....Yes ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None 1141V-12 W-(00 Other (specify) SiM,N il-C- G'a Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes g No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications\Forms- Applications On Line\2012 ApplicationsU'ermit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* V4 /G., Attached Garage hqw Detached Garage VI /Gc. Attached Carport Detached Carport Covered Deck w I Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None 1141V-12 W-(00 Other (specify) SiM,N il-C- G'a Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes g No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications\Forms- Applications On Line\2012 ApplicationsU'ermit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN ��.. OR/ AUTHORIZED AAGENT Signature: (di'I-V Cif ✓ (11- L Gt �, Print Name: Date: ` " 1 Day Telephone: ()a - 4/3/-343 Mailing Address: `5J-7 ?Sl So 1/t (.W 0?3 ct (!(;d ,iatzttacc ILM q, /5/' City State Zip H:Applications\Forms- Applications On Line\2012 Applications\permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 4 of 4 PUBLIC WORKS PERMIT INFVIATION — 206 -433 -0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by„'ng County Health Department. 0... Highline ❑ ...Valley View 0... Renton ❑ ...Sewer Availability Provided ❑... Renton ❑... Seattle Submitted with A r r Iication mark boxes which a ❑ .. Civil Plans (Maximum Paper Size ' 2" x 34 ") ❑ .. Technical Information Report (Storm 1 ainage) ❑ ... Geotechnical Report ❑ .. Bond ❑... Insurance ■ ... Easement(s) 0... Maintenance Agreem Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for less than 72 +urs ❑... Right -of -w Use - Profit for less than 72 hours ❑ .. Right -of -way Use - No Disturbance ❑... Right -o ' ay Use — Potential Disturbance ❑ .. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ork in Flood Zone ...Storm Drainage ❑ .. Sanitary Side Sewer 0... Abandon Sep . Tank 0... Grease Interceptor ❑ .. Cap or Remove Utilities 0... Curb Cut ,° 0... Channelization ❑ .. Frontage Improvements 0... Paveme : ut 0... Trench Excavation ❑ .. Traffic Control 0... Loop - ire Line 0... Utility Undergrounding ❑ .. Backflow Prevention - Fire Protection " Irrigation " Domestic Water ❑ .. Permanent Water Meter Size (1) WO # (2) " WO # (3) " WO # ❑ .. Temporary Water Meter Size (1) " WO # (2) " WO # (3) " WO # ❑ .. Water Only Meter Size " WO # 1 .. Deduct Water Meter Size ❑ .. Sewer Main Extension Pu ❑ Private ❑ ❑ .. Water Main Extension P . is ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Lin: Number of Public Fire Hydrant(s) ❑ .. Water I . Sewer ❑ .. Sewage Treatment Monthly Service Billin Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip FR Applications On Line\2012 Applications\Permit Application Revised - 2-7-12 docx Revised: February 2012 bh Page 3 of 4 • i City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 8141400580 Address: 15278 SUNWOOD BL TUKW Suite No: Applicant: STETSON RESIDENCE RECEIPT Permit Number: D12 -392 Status: APPROVED Applied Date: 12/17/2012 Issue Date: Receipt No.: R13 -00261 Payment Amount: $283.30 Initials: JEM Payment Date: 01/14/2013 08:59 AM User ID: 1165 Balance: $0.00 Payee: KATHRYN A STETSON TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 826707 ACCOUNT ITEM LIST: Description 283.30 Account Code Current Pmts BUILDING - RES STATE BUILDING SURCHARGE 000.322.100 278.80 640.237.114 4.50 Total: $283.30 dnr. RAc. int -OR PrintAd. 01 -14 -9013 City otTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 8141400580 Address: 15278 SUNWOOD BL TUKW Suite No: Applicant: STETSON RESIDENCE RECEIPT Permit Number: D12 -392 Status: PENDING Applied Date: 12/17/2012 Issue Date: Receipt No.: R12 -03333 Initials: JEM User ID: 1165 Payment Amount: $181.22 Payment Date: 12/17/2012 01:18 PM Balance: $283.30 Payee: KATHRYN A STETSON TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 656274 ACCOUNT ITEM LIST: Description 181.22 Account Code Current Pmts PLAN CHECK - RES 000.345.830 181.22 Total: $181.22 rtnr.• Rar.Pint -0R PrintMrl• 12 -17 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila. WA 98188 (4— (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 D/2 -3521 Pr c1 lrit .5 0 a o TYPV�ns ct L , In , G Address: S 2-f7 S Date Called: Special Instructions: Date Wanted:., � � ( ' `3 ate, m Requester: Phone S3 '212 - - -L- ( l Approved per applicable codes. Corrections required prior to approval. COMMENTS: -ej-WT wl (sector: Date ri REINSPECTION FEE REQUIRED. for to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suit 100. Call to schedule reinspection. e2 INSPECTION RECORD Retain a copy with permit INSPECTIZ N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 ib.124.q Project: se..% 1a N'4.- Type of Inspection: Address: I 1-1..-1 ' c to n1 uJ exa Date Called: ad - Special Special Instructions: Date Wanted:. 2-- 3 1- t • .a.m: ep.,ma Requester: Phone No: ! - et✓ 1 4 Z'S C `.� 6!,-5:31 -`- Approved per applicable codes. D Corrections required prior to approval. COMMENTS: e�or: Date: RiINSPECTION FEE ' EQUIRED. i-ior to next inspection, fee must be • paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • f INSPECTION NO. r• • INSPECTION RECORD Retain a copy with permit • PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431 -3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project: r 5 0 J ,4 `teA Ctlype "' r s�p�ect Ant A6 r`` �\ Address: s-Z�F t cL1NW064 Date Called: Special Instructions: Date Wanted:r. .-"m,, (— (LI ., /3 P.m. Requester: Phone 3 -..E3 -2177g Approved per applicable codes. COMMENTS: ElCorrections required prior to approval. :Lliot agi4e-ya% it--ItePrYui/t, air-roved Inspector: Date: /+21 _ Z/� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 012 • ' - • INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. • • • CITY.OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 • • P.errriit Inspection Request Line (206) 431 -2451 Project N eo1 D Type of Inspectio : F�Gem;1 Nstll t Address ��"�'' &_ ®�t'� Ni � Date Cal101 � �`� 4. Special Instructions:. • • Date Wanted� /�A a. Requester: / Phone o: 3 023 Z775 (Approved per applicable codes. Corrections required prior to approval. COMMENTS: de pt F? -.- tUt co REINSPECTION FEE REQUIRED. Prior to next inspection; fee tnust,,.be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 l (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 L312 -3.- Project: r:� S to NJ Type of Inspection: t- n i l k rQ COMMENTS: Address: I .2- 7 P) sZIn1Wbo t7 Date Called: 1A i,IV c: vi t', Iro . Special Instructions: C1,4 ,. 1 Date Wanted:. i — 1%- 17S - - {0-"- 6-m. p.m. Requester: Phone No: 3-53 -- z23--27 7 E1Approved per applicable codes. Corrections required prior to approval. 3 ri INSPECTION FEE REQUIRED. Prior tO next inspection, fee must be a. 1d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: COMMENTS: {.' Vv`- f. -\ \ *'s•, i r - :? I t'p■1':a •J(.01,An...t y ( .' Qv) 1A i,IV c: vi t', Iro . L.J.A: 4 ....I`1 -C.:) .i nc. C1,4 ,. 1 ---,,i- . . - - {0-"- • {i0sr. 4erl )1atld'c°cl rte►, 1 ri INSPECTION FEE REQUIRED. Prior tO next inspection, fee must be a. 1d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (,v_ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 D12 -34- Project: Type of Inspection: • Address: \ 5 2 7 'J cv ; ,.l woo Date Called: • ? VI £4.444.341 /C i i r . Special Instructions: • • Date Wanted:. - I Cs - t Z, Ca m tr.'e Requester: i - -G3 ,36 � Phone No: •,./.-.S 3 -z. ? s-2.7),3 . IZApproved per applicable codes. Corrections required prior to approval. COMMENTS: • RAv ;P &( ?Incas y4.0 ,APoPti /'R9'vmlet G . ) 00 Rd44 t ) O p / S0d e5. ;A1 c41; // - - AJvlg- • ,,C.7) aR /1 -Air . AkVaP#rT /d+a) 4 »-,.S46 "i-■1, i - -G3 ,36 � r Inspe tor: ! c...44. —7 Date: /— / G _/ 3 . EINSPECTION FEE EQUIRED!Prior to next inspection. fee. must be • paid at 6300 Southcen r Blvd., Suite 100. Call to schedule reinspection.. EXISTING —� WALL FRAMING NEW h" SHEATHING W/ -- 8d ® 6" AT ALL PANEL EDGES & © 12" IN FIELD. EXTEND SHEATHING TO BOTTOM OF CLERESTORY WINDOWS a -3GZ RECEIVED JAN 17 2013 BUILDING DEPARTMENT. EXISTING ROOF JOIST NEW BEAM PER PLAN EXISTING (2)2x10 REVISED SECTION `. A35 © 4' —O" NOTE: IN LIEU OF 4x6 POST @I BEAM ENDS, PROVIDE (3)2x4 MIN 3/4" = 1 -0" LEWIS ENGINEERING CONSULTANTS 19229 99th South Renton, Washington 98055 Phone: (253) 520-4120 Fax: (253) 681-8349 DESIGNED ksl DRAWN ksl STETSON RESIDENCE SCALE NTS DATE 1/17/13 JOB NO. 21 -117 15278 SUNWOOD BLVD #C32 TUKWILA, WASHINGTON SHEET SK1 OF Structural Calculations for the Stetson Residence 15278 Sunwood Blvd, #C32 Tukwila, Washington Designed for: RJBJR Design Robert Bonner www.robertbonner.com www.rgbjr.com 425 - 279 -3317 Designed by: Lewis Engineering Consultants Job #21 -120 September 13, 2012 FILE COPY pow mom. Kristi Lewis 19229 99`h South Renton, WA 98055 Phone: (253) 520-4120 fax: (253) 681 -8349 email: lewis790@comcast.net REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 0 2012 City of Tukw1l6 BUILDING DIVISION 4')Gl96W' ONAte /:'' I �;, CITY OF TUKiRp. it, DEC 1 12012 PERMIT CENTS 'VS j 7(-6 /44eirai?(, LO 1 Sic �� -.� . ,, aC 4_,- i 6-0 t-__ft d 3 J_ 6. _- 1 __3 5 ka_SS •es-r- :Lo A-K 5y`c414 n _" L` av (.CG Tt c- kApa_ 4 4TY (f 4$ � 1 "i-_. i 1-781 SLR , Lilt ri� ,1V ,1 -\ W M (�jj 1 1f`l i I 1 2- Tr _11)(51,-)-- t5ir-sp ---. A SYYI IC_ i { 1 'Cl. 50-/V:i j 0:1-0--- k , e re ` i a-s ion e. 6, C F. .�rx i yle,b,i eke LEWIS RENTONTWASH G ON 8055 ENGINEERING NE. 65,2:141 IN CONSULTANTS, INC. n I -- I (� � IP 13 JOB # BY DATE PAGE STRUCTURAL NOTES r'1,44 EIPP:E34.:1•1P 54.111 1407. Pp E,1:1NO, 4351'145 10 BEI E741 YEII1APEL• As'. CY:5.4, : E:ap114JCTI5: 1474, PI,OP.,,, •FK ;74'17' 17?g:7; ;5,3; 74r4 .:P:Et • DL S: 41151 0,51 (*1000 441) . 44541? 4 77,1357 A,ID 01112ED ALL :P. 3./ :NO cc HE,,t p(p *.1) p 3:17404 5415,5 471D PtAIES E44.1 BE 4:0 B.P. COIr34f,C1B.:, scrE» T41040 MID EIPABCP. BIWA 10 THE: 0E:10BEEBBIS Pr031 0:10107 4140: 8,1145 40 1:04158 P0PP:01 5::74157 BP.P:50010 :;00::: TO P.pPAEL 0(1 BBE'APPBE TPE,Et PEP :14310 5100; 5.34,1 BE BAPKD • (1.7)63 }Op (,p1155 t413441105 15 050191 II:405411034 A? copp:ks kg•I A, er1:4EV:1301( Prn E 0154 14,54,Ird 15 BANI.SP,7o6ED IP•••5 341111PIP,0LE:1411 *Cop G440145 l()11341001( 01157171074 14441.1 BE 514457PIP:IED 10 BPE ..anaatrA 1144.014RD Or 13E 85. :•PE 41E0) EI:OBE • : 14E. Poi •10:7 0 EA-, I I . . ST.B.E. WALE 7, BE 0110 00 8:4 0/ \ Brr,S Ftp 1 t O : S...P•B; P.111 BLAP1p!.!BELC19 \ 5 NAILS. 547.77. AND COILIPEBIOaS 4,75(01 01.E.BE tan. , twirl* 1/411:11.0 SPEALL. . 011:05214 10 le: ',ell 57:44;4.1. 0.1 IP.M.F, 'PPM.: BE 4.•11471,:1 AiPE N.,..: 00154E:I17: 1601,4 81 :u,, ,R:on:-X OA AP114.1,440 154044. , , .:, I • • ; I... ... . ....P11II5rp.159•I4.07111 ...2-7.......Er. , - . . PrIE,.-IBLAIA ABB 3E41,4)30144 I:54114Er:1P1.1. 5.144 et MADE IP:PIC LIY. EASE Br. BP..., VPIIIEBTOBS. SPAPSON 07 CVJAI. I ,B..• . • . . . 51081 1 . I SLOPE 0 54(1 40 P.SP:CIrm 1,.. P40:4434 A: POE141 1 PEP ■BC 1:P41IPE0 I i • A 5014CPC17. rc - 2500p,--701 POEPPED 1,, I • a *3C7 A■414071 Ea,: PI CO.C.E7C (PEP 17P:4:pl.-NOT REB1PPED i • . . . _ . • • . 1 CP.PustOloPS PI 50747ACT 5f70 PIPESSIoPE 70E44E9 Pf:I00 Att :01.155110:15 01 .. . • • . 111,144'; 1115 410071(141 4044134 *515*' 0(4415 01 47)1 0104141'14101li15005?(04 51 944*4150 1110411 4*37 *470(0 044,44404(1(1 ra,ltor*9 5*3040 0+4445(1* 10 45744 4(51 4*10 4101 04+CE7 11A44444154,5 5041. 0104000* 70 A...:11.1 A1.55 1801141; C05040*1101: 0-1551 V104350 91(54 rABILrai, MIS CO./EMPB 55011 • 14:1 TO< oP 3,8 (ELEC1Fe.I.,E0 (AL...a:ED 7A5ID4P5 AuD 911411te7165 4140 140110 EIL mim 70(15080 70111E1?, 74150 514445411 PROGo.:1 4ReS0E5 COPIPEEPORDPie IC, TPIE 4e1107. PE04037uEB79 APE ZIAAP (MT IBOPED rhPANIZ(D) MIS 4:7340 I:I447a7115 ST(4- SECOND FLOOR FRAMING PLAN BAIA CPABlei, 100 5E1094 KOPP' BE. 01 Pei t1- Al ALL EtPBE 44 0 121. 01:10 SECTION PO,,r .4 3407 T p:Pr, AL. ,:rE.1:::1715 BE 1 854.11183451,4,11:. ,E7 BO.IA,. P.WEr-A,BPP 1E. ',YE Fi'..4EB 074, ELOP2EtP gr Dr.,:pt,A.:EB.a De,. STETSON RESIDENCE -J I LBW: P!....E 1, 4(01(0 7,44 A:IP ea, I — Ili I S 1 MEMBER REPORT Level, Wall: Header V Oy1 T E 1 piece(s) 5 1/4" x 11 7/8" 2.0E Parallam® PSL 0 Overall Length: 14' 7" 14' 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Loads Combination (Pattern) Member Reaction (lbs) 5684 @ 2" 13322 (3.50 ") Passed (43 %) -= 1.0 D + 1.0 S (AU Spans) Shear (lbs) 4685 @ 1' 3 3/8" 13861 Passed (34%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs) 19786 @ 7 3 1/2" 34332 Passed (58%) 1.15 1.0 D + 1.0 5 (All Spans) Uve Load Dell. (in) 0.323 @ 7' 3 1/2" 0.475 Passed (L/529) -- 1.0 D + 1.0 5 (All Spans) Total Load Dell. (In) 0.530 @ 7' 3 1/2" 0.712 Passed (1/323) -- 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (1/240). • Bracing (W): All compression edges (top and bottom) must be braced at 14' 7" o/c unless detailed otherwise. Proper attachment and positioning of lateral tracing is required to achieve member stability. Supports Bearing Length Loads to Supports (lbs) Accessories Total Available Required Dead Snow Total 1 • Trimmer - HF 3.50" 3.50" 1.50" 2220 3464 5684 None 2 • Trimmer - HF 3.50" 3.50" 1.50" 2220 3464 5684 None Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for Installation details. (www.woodbywy.com) Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Use of thls software Is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer Is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. The product application, Input design loads, dimensions and support information have been provided by Forte Software Operator Forte Software Operator K■.ti • LEG i Ofil81h.ar ;r, Id�:is7�0ic:um:.aat rut Job Notes PASSED System : Wall Member Type : Header Building Use : Residential Building Code : IBC Design Methodology : ASD SUSTAINABLE FORESTRY INITIATIVE X13 9/12/2012 8:31:47 AM Forte v4.0, Design Engine: V5.6.1.203 Page 1 of 1 Tributary Dead Snow Loads Location Width (0.90) (1.15) Comments 1 - Uniform(PSF) 0 to 14' 7" 19' 15.0 25.0 Residential - Uving Areas Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for Installation details. (www.woodbywy.com) Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Use of thls software Is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer Is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. The product application, Input design loads, dimensions and support information have been provided by Forte Software Operator Forte Software Operator K■.ti • LEG i Ofil81h.ar ;r, Id�:is7�0ic:um:.aat rut Job Notes PASSED System : Wall Member Type : Header Building Use : Residential Building Code : IBC Design Methodology : ASD SUSTAINABLE FORESTRY INITIATIVE X13 9/12/2012 8:31:47 AM Forte v4.0, Design Engine: V5.6.1.203 Page 1 of 1 *EMIT COORD COP* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12- 392___ DATE: 12/17/12 PROJECT NAME: STETSON RESIDENCE SITE-ADDRESS: 15278 SUNWOOD BL; #C32 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: At - tg-10)` Building Division Lig 1)1'61 NIik \ 1W'1I- Public Works ILEJ 'bT AO Fire Prevention Structural r Division 1(1-.1412— ❑ Planning Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12/18/12 Complete T Incomplete ❑ Not Applicable ❑ Comments: Perinit Center Use'Only.! s :; • p��: a� �:, e ' `' ':i }" INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/15/13 Approved ❑ Approved with Conditions jk Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only . CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople,nter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name BLUE MOOSE HOME SERVICES LLC UBI No. 603125973 Phone 2539451394 Status Active Address 817 5 314Th St License No. BLUEMMH898ME Suite /Apt. License Type Construction Contractor City Federal Way Effective Date 7/5/2011 State WA Expiration Date 7/5/2013 Zip 98003 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status BLUEMMH902LM BLUE MOOSE HOME SERVICES Construction Contractor General Unused 6/14/2010 6/14/2012 Expired Business Owner Information Name Role Effective Date Expiration Date ROHLEDER, PATRICK J Partner /Member 07/05/2011 Amount ROHLEDER, MICHAEL EDWIN Partner /Member 07/05/2011 46- 10162560 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 American Contractors Indem CO 100168756 07/01/2011 Until Cancelled $12,000.00 07/05/2011 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 Navigators Ins Co 46- 10162560 07/01/2012 07/01/2013 $500,000.0006/26 /2012 1 Navigators Ins Co 4610146192 07/01/2011 07/01/2012 $500,000.0007/05 /2011 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 01/14/2013 12' -3" 11' -2" 9'-3" -en LIVING RM. 3' -0" POYER — ∎— OWLINS TRANSITION 14OR1i-I HALLWAY 0- �EDRT L / / / / / / CAS 1 NET / / / f MICROWAVE/ HOOD 4OMBO POT rAu LLER / / / / / / CAE / / / / / / / / / / / / NET / / / / / CET SLIDER 1 SLIDER BOTTLE WINE FRIDGE 1S "Dal. SLIDER SLIDER SLIDER SLIDER / / / / / CAI; / / / / / / NET / / / / / SLIDER SLIDER SLIDER PROPOSED KITCHEN F1-04N1 scale 1/4"= 1'-0" WE INTEIO KI1CS41 ELEVATION scale ia"= 1'-0" cA NET REP. REVISIONS ''ages shall be made to the scope work without prior approval of Tukwila Building Division, '3visions will require a new plan submittal I include additional plan review fees i SEPARATE PERMIT REQUIRED FOR: Electrical &gee Piping City of Tukwila BUILDING DIVISION 4 Permit o. : $12. ptN% rrew approval is su to Ms and omissions. &:: ;J•f1 '_ or construction documerds does not akithtnts Receipt �.�: Of �n or ordinance. �i.3 �ti .:.�c�}IS F � �. et, proved Field Copy and conditions isacknowledged: By Datt 1- I�{-f3 City Of'f tkvilla BUILDING DIVISION FOR E COMPLIANCE APPROVED DEC 202012 city ofTukwila BUILDING DIVISION EAST INTERIOR KITCHEN ELEVATION scale I/2 "• P -Pl" NORTH INTERIOR KITCHEN ELEVATION scale 1/2": I' -m" I~i,��I1t r.t) CITY OF "WOW 1... DEC .17 2012 PERMIT CENTER WRITTIr4 ON TWIN D RAIUINdle WALL. I. WAVU PIaC/ONCR !MI! WALED DIMINSIONS. ccwii ACTOR SNAIL CMWOIC AND WOW ALL' DPIINSIONS AND CONDITIONS PRlT'ANINS To TNW PROMO? PPM TO TOM OCIINST UCTION WAGS 11' Ii 1wIW CGNTIIACTiORi IRWsPcwsi*ILMY TO IDNNITIPY A{.L DI CIIMPAN DIMI TO TNW OWIRINIM AT T141 TIM M 1/4111Y AIRW NOM. TMW 0111SI4N IS e U we IMAM CORK ANY USW OIR RRPRODUOTION OP ouM14N Is NOT AUTMO N= MIMS *MR CORP. ALLOWS UN OP DO M. ROM COW 1"us N NOTIINWD OIL ANY • vA RIATION RIM TON DIMINNONS AND/OR CONDITION* SWIM ON TMWSW DIRAWN1110. ANY SuCN VARIATION SNALI. SI R __I.II•D PRIOR TO I�ROCMIDINW WITH TMi WOIMC OR TOM CONTRACTOR MALL ACOWPT DULL ItlaPON IMI LM'YPOI! COWL' TO RAIGTPY AIL IN 114I WANT ANY LIARI.M'Y l$ MOOD ON RwrJR CORK OUR LIAOILI1Y TO YOU OR ANY' 1±NIRD PARTY SHALL NOT T1411 PIM PAID POI ROLM CORP. PRODUCT. ANY uNAUTNORI=0 ALTRRATIONS OP 1141811 DIRAWINft WIY IWO CONTRACTOR leNDAOIR T141118 PARTY, TNI. CON? ACTOR . AND/OR THIRD MAW GNAW. MOLD IROINIR COIRP. HARMLa & wwwOt11 rg b r.doetgn ROBERT BONN 618 TOBIN 8f. RCNTON, WA 42E+. 219. 3311 INPOIRODIIRTISONNIPLCOM project title: STETSON CONDO PROJECT 16218 SUNWD BLVD. *C32 tUKWILr4, WA 98188 EXISN3R O; ?PN revisions:.. CONCRP1"6: 06-22 -12 DiION L7EIIELOPMNNt: 00-11 -12 CONSTRUCTION DOCUMNNTes 00-28 -12 PRRMIT MT: 10 -26 -12 1)124-12 SOUI1•4 INTERIOR KITCHEN! ELEVATION scale I/2"= 1'-0" drawing no. MRCS,. NUMMI% AUG PJb, 2012 1 SLIDER SLIDER BOTTLE WINE FRIDGE SLIDER SLIDER SLIDER SLIDER EAST INTERIOR KITCHEN ELEVATION scale I/2 "• P -Pl" NORTH INTERIOR KITCHEN ELEVATION scale 1/2": I' -m" I~i,��I1t r.t) CITY OF "WOW 1... DEC .17 2012 PERMIT CENTER WRITTIr4 ON TWIN D RAIUINdle WALL. I. WAVU PIaC/ONCR !MI! WALED DIMINSIONS. ccwii ACTOR SNAIL CMWOIC AND WOW ALL' DPIINSIONS AND CONDITIONS PRlT'ANINS To TNW PROMO? PPM TO TOM OCIINST UCTION WAGS 11' Ii 1wIW CGNTIIACTiORi IRWsPcwsi*ILMY TO IDNNITIPY A{.L DI CIIMPAN DIMI TO TNW OWIRINIM AT T141 TIM M 1/4111Y AIRW NOM. TMW 0111SI4N IS e U we IMAM CORK ANY USW OIR RRPRODUOTION OP ouM14N Is NOT AUTMO N= MIMS *MR CORP. ALLOWS UN OP DO M. ROM COW 1"us N NOTIINWD OIL ANY • vA RIATION RIM TON DIMINNONS AND/OR CONDITION* SWIM ON TMWSW DIRAWN1110. ANY SuCN VARIATION SNALI. SI R __I.II•D PRIOR TO I�ROCMIDINW WITH TMi WOIMC OR TOM CONTRACTOR MALL ACOWPT DULL ItlaPON IMI LM'YPOI! COWL' TO RAIGTPY AIL IN 114I WANT ANY LIARI.M'Y l$ MOOD ON RwrJR CORK OUR LIAOILI1Y TO YOU OR ANY' 1±NIRD PARTY SHALL NOT T1411 PIM PAID POI ROLM CORP. PRODUCT. ANY uNAUTNORI=0 ALTRRATIONS OP 1141811 DIRAWINft WIY IWO CONTRACTOR leNDAOIR T141118 PARTY, TNI. CON? ACTOR . AND/OR THIRD MAW GNAW. MOLD IROINIR COIRP. HARMLa & wwwOt11 rg b r.doetgn ROBERT BONN 618 TOBIN 8f. RCNTON, WA 42E+. 219. 3311 INPOIRODIIRTISONNIPLCOM project title: STETSON CONDO PROJECT 16218 SUNWD BLVD. *C32 tUKWILr4, WA 98188 EXISN3R O; ?PN revisions:.. CONCRP1"6: 06-22 -12 DiION L7EIIELOPMNNt: 00-11 -12 CONSTRUCTION DOCUMNNTes 00-28 -12 PRRMIT MT: 10 -26 -12 1)124-12 SOUI1•4 INTERIOR KITCHEN! ELEVATION scale I/2"= 1'-0" drawing no. MRCS,. NUMMI% AUG PJb, 2012 1 STRUCTURAL NOTES 1. GENERAL: STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO BIDDING OR CONSTRUCTION. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AND SHORING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN MADE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES NECESSARY TO PERFORM THE WORK IN A SAFE WORKMANLIKE MANNER. THE DRAWINGS ARE INTENDED TO INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED. EXISTING STRUCTURE IS ASSUMEDT TO BE STRUCTURALLY SOUND AND IN GOOD CONDITION. 2. CODE: CONSTRUCTION SHALL CONFORM TO THE 2009 INTERNATIONAL BUILDING CODE. 3. DESIGN LOADS: SNOW FLOOR LIVE WIND SEISMIC 25 POUNDS PER SQUARE FOOT 40 POUNDS PER SQUARE FOOT BASIC WIND SPEED = 85 MPH 3— SECOND GUST, EXPOSURE B, Kzt = 1.00 SITE CLASS D, R = 6.5 FOR LIGHT FRAMED WALLS WITH WOOD SHEAR PANELS 4. TIMBER AND LUMBER: ALL 2X, 3X AND 4X MEMBERS SHALL BE HEM FIR NO. 2 OR BETTER. STUDS AND PLATES SHALL BE HEM FIR, CONSTRUCTION OR BETTER. ALL TIMBER AND LUMBER SHALL CONFORM TO THE REQUIREMENTS OF WWPA GRADING RULES. PLATES AND OTHER MEMBERS IN COTACT WITH CONCRETE OR EXPOSED TO WEATHER SHALL BE PRESSURE TREATED PER IBC 2303.1.8. STUDS SHALL BE CAPPED WITH DOUBLE TOP PLATES INSTALLED TO PROVIDE OVERLAPPING JOINTS AT CORNERS AND AT INTERSECTION WITH BEARING PARTITIONS. PSL SHALL E 2.0E PARALLAM AS MANUFACTURED BY TRUS JOIST MACMILLIAN. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARD OF THE IBC. 5. NAILS, BOLTS AND CONNECTORS: UNLESS OTHERWISE NOTED, MINIMUM NAILING SHALL CONFORM TO IBC TABLE 2304.9.1. ALL NAILS SHALL BE COMMON WIRE NAILS. CONNECTORS SHALL BE SIMPSON STRONG -TIE OR APPROVED EQUAL. POST /BEAM AND BEAM /BEAM CONNECTIONS SHALL BE MADE USING LIGHT GAGE METAL FRAMING CONNECTORS, SIMPSON OR EQUAL. SPECIAL INSPECTION IS REQUIRED AS FOLLOWS PER IBC CHANPER 17: A. CONCRETE: f'c = 2500psi - -NOT REQUIRED B. A307 ANCHOR BOLTS IN CONCRETE (PER 1704.4)- -NOT REQUIRED . CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD: ALL CONNECTIONS IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE HOT DIPPED GALVANIZED STEEL OR STAINLESS STEEL. HOT DIPPED GALVANIZED FASTENERS SHOULD CONFORM TO ASTM A153 AND HOT DIPPED GALVANIZED CONNECTORS SHALL CONFORM TO ASTM A653 (COATING DESIGNATION G -185). STAINLESS STEEL FASTENER AND CONNECTORS SHALL BE TYPE 304 OR 316. (ELECTROPLATED GALVANIZED FASTENERS AND CONNECTORS ARE NOT TO BE USED WITH PRESSURE TREATED WOOD. SIMPSON PRODUCT FINISHES CORRESPONDING TO THE ABOVE REQUIREMENTS ARE ZMAX (HOT DIPPED GALVANIZED) AND SST300 (STAINLESS STEEL. SLOPE EXISTING WALL TO BC REMOVED. PROVIDE SHORING AS REQ'D EXISTING ROOF JOIST 0 2' -0" NEW 4x6 POST 0 EA END OF PSL W/ SIMPSON PC POST CAP. ALIGN W/ BEARING WALL BELOW a AR SLOPE XISTING ROOF JOIST ® 2' -0" EXISTING WALL TO BE REMOVED. PROVIDE SHORING AS REQ'D EXISTING ROOF JOIST 0 2' -0" SLOPE XISTING ROOF JOIST CAD 2' -0" PLAN NOTES: 1. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL PLANS 2. CONNECTORS SHALL BE MANUFACTURED BY SIMPSON OR APPROVED EQUAL. 3. CONTRACTOR SHALL PROVIDE SHORING AS REQUIRED. 4. CONTRACTOR SHALL NOTIFY THE ENGINEER OR ARCHITECT OF ANY DISCREPANCIES IN EXISTING CONDITONS. SLOPE SECOND FLOOR FRAMING PLAN 1 /4" = 1' -0" (1) NEW if SHEATHING W/ 8d 0 6" AT ALL PANEL EDGES & 12" IN FIELD SECTION 3/4" = 1' -0" REVIEWED FOR ;CODE COMPLIANCE APPROVED DEC 2 0 2012 City of Tukwila BUILDING DIVISION REC►LIVEU CITY OF Tutoilnuo, DEC 1 ,/ 2012 PERMIT CENTER. S19229 99th Place South Renton, Washington 98055 3I NG Phone: (2 3j 681 -8349 ANTS _j 2 STRUCTURAL NOTES, ROOF FRAMING PLAN AND SECTIONS 15278 SUNWOOD BLVD #C32 TUKWILA, WASHINGTON