Loading...
HomeMy WebLinkAboutPermit D12-397 - SUNWOOD CONDOMINIUMS - ROT DAMAGED DECK REPAIRSUNWOOD CONDOS 15255 SUNWOOD BL D12 -397 City oPi'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 8141400190 Address: 15255 SUNWOOD BL TUKW Suite No: Project Name: SUNWOOD CONDOS DEVELOPMENT PERMIT Permit Number: D12 -397 Issue Date: 01/08/2013 Permit Expires On: 07/07/2013 Owner: Name: CARLSON KJIEL Address: PO BOX 731 , GIG HARBOR WA 98335 Contact Person: Name: RUDY YOUNG Address: 3400 188 ST SW, STE 302 , LYNNWOOD WA 98037 Phone: 425 774 -5600 Contractor: Name: CLANNADH LLC Phone: 425 - 898 -9185 Address: 23316 NE RED -FALL CITY RD, SUITE 608 , REDMOND WA 98053 Contractor License No: CLANNL *909DW Expiration Date: 04/09/2014 Lender: Name: N/A - SUNWOOD CONDO HOA Address: DESCRIPTION OF WORK: UNITS A13, A23, A33 & A26: (2) DECK REPAIR PROJECTS. WORK TO INCLUDE REMOVAL OF EXISTING ROT DAMAGED DECK ASSEMBLIES, REPLACEMENT WITH NEW DECK COATING MEMBRANES, FLASHINGS, AND NEW ALUMINUM PICKET RAILING SYSTEM. NEW RAILINGS SHALL BE A "DEFERRED" SUBMITTAL PER ENGINEERING. Value of Construction: $9,107.00 Type of Fire Protection: Type of Construction: Electrical Service Provided by: Fees Collected: $464.52 International Building Code Edition: 2009 Occupancy per IBC: 0021 * *continued on next page ** doc: IBC -7/10 D12 -397 Printed: 01 -08 -2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: N Number: 0 Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: ff (- g- [ I Date: 3 1 hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t - _ : - work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this pe Signature: Date: 7 Print Name: � -2C'3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -397 Printed: 01 -08 -2013 CITY OF TULA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TUkwilaWA.gov Building Pet Ault No. Project No. Date Application Accepted: Date location Expires: CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION j4 24r r' L: t3,r '+ Is LAN if '2 (0,0. Site Address: Tenant Name: -/ Th" SUN k t»O i;: vo PROPERTY OWNER Name: .San.r r OW, C 2oNl f/"f tii'9 C IAA. Address: /5/ oo C',,.,, w. o» 13( -VD. City: 7!G w I c-R State: i/Vi4 Zip: trI rr CONTACT PERSON - person receiving all project communication Name: R,vp Y X., �A,6, Address: 3 ,t®, / d► P7`-s, gy- Sw City: State'jf, Zip: 94,037 Phone: ?2s, 77 it S'(o » Fax: 4l -.. ?75/5'`6 / Email: Rc-eY Y 0 (J2 Gn- rv4r7/ra , co", GENERAL CONTRACTOR INFORMATION Company Name: Address: .2.3 5 / (o NE geo(wwns,( /Z4 #Gep City: State: yt/,q. Z,p t to S3 Phone: f2' • 7 9 • 7/� Fax: 42�v� od, ,731,0 ! Contr Reg No.: Exp Date: Tukwila Business License No.: H: Applicaflons Forms-Applications On Line 2011 Applications Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh King Co Assessor's Tax No.: q H I"i OQQi L I O o7 /U''' Suite Number: Floor: New Tenant: ❑ Yes ❑ ..No ARCHITECT OF RECORD Company Name: JZ By i 4..0 f "G ruc. n /44 Architect Name: / s,/ Yov vG Address: 3 `f rx, i gs'* -, S7 SI-v Sw)/e S'oz City: G y,t "„ act State: bv4 Zip: •frop Phone: f26.-- .771c. r... Fax: 72r• 779,5-64r Email: „:„.,4y y V d J.. cn,,, sv c.rnwrf. 430.1 ENGINEER OF RECORD Name: iNi1010)/ Oa 004A f 1,I1.4/fS Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: iNi1010)/ Oa 004A f 1,I1.4/fS Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATIOI-!06- 431 -3670 Valuation of Project (contractor's bid price): $ 9 RP 7 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): /2A0•1 - God I cry 0la Cz) P c1e- IrI•L— YEA - / ADJe6rS �}r 13UlLD /ivy 1;41" of ]7ff 41/ Niev (ier'O' "i A I / " (mow► 1121.01C • 14o#2&- (, - 11;k •v tz+ OP- e /rr /,u(, R or PAS -r/+-G e D DEex .4 sr Fs, R E7°G..*c erie r Gtr! -E'k. I7ecic Go�tyN �!e -i >3 �-pNE s FLotSdrl Na / /4.7,12 /V - /4 P<'4 7 ea A./ /A. 5'is pr N ew Ar-/ L. ENG- Strict -c_ Se- A- IP E7' rQ '2 Sv a-4.7 P 6 f d 60.2_ Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below N m r ■4--2/9 i c.4r>3 c C a' ° rvD' ( ) PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Floor area of accessory dwelling: Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? ❑ Yes ❑ No If ',yes", explain: Handicap: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2 " x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:.Applications '•Forms - Applications On Line' 2011 Applications Permit Application Revised - 8 -9 -I Ldocx Revised: August 2011 bh Page 2 of 4 1 Existing ' ' "16 `` Interior Remodel • Addition to '.•;' Existing Structure =a ,.L4 • . New •' • 'Type of Construction per IBC Type of Occupancy per IBC 1St Floor Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage . • • Detached Garage . Attached Carport Detached Carport • . Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Floor area of accessory dwelling: Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? ❑ Yes ❑ No If ',yes", explain: Handicap: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2 " x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:.Applications '•Forms - Applications On Line' 2011 Applications Permit Application Revised - 8 -9 -I Ldocx Revised: August 2011 bh Page 2 of 4 1 PERMIT APPLICATION NOTES - • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE • 1 R AUTHORIZ D AGENT: Signature: Print Name: Mailing Address: 3' I- D S•fi Sw H:Applications`Forms- Applications On Line 2011 Applications Permit Application Revised - 8 -9 -1 I.docx Revised: August 2011 bh Date: l--b- 49 ?e, Day Telephone:2-0 • 9 141 • 1 lg.b L wcro. 4 LA) A- I $03 7Z cry state Zip Page 4 of 4 i PUBLIC WORKS PERMIT INFO TION — 206 - 433 -0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila • ❑ ...Sewer Use Certificate Septic System: ❑ On -site Septic System — For on -s septic system, provide 2 copies of a current septic desi 0—Valley View ❑...Sewer Availability Provided ❑ .. Highline ❑ .. Renton Submitted with A t . lication ❑ ...Civil Plans (Maximum Paper Size — ❑ ...Technical Information Report (Storm ❑ ...Bond ❑ .. Insurance mark box which a . 1 I " x 34 ") Dr age) Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hour ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ .. Geotechni ❑ .. Mainte Report ce Agreement(s) ❑ .. Renton attle ❑ -. approved by King County Health Department. ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ . +` fight -of -way Use - Profit for less than 72 hours ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑. ❑❑. ❑. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone .. Storm Drainage . Aban� .n Septic Tan . Cur/Cut . P. ement Cut . ooped Fire Line ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension ❑ ...Water Main Extension If ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding WO # WO # WO # Private ❑ Private ❑ ❑...Deduct ater Meter Size FINANCE INFORMATION Fire Line Size at Property Lin: ❑ ...Water ■...Sewer Monthly Service Billin Name: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: Mailing Address: Zip Water Meter Refund/Billing: Name: Mailing Address: City State Day Telephone: City State Zip H:.Applications',Forms- Applications On Line. 2011 Applications,Permit Application Revised - 8 -9 -1 Ldocx Revised: August 2011 bh Page 3 of4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 8141400190 Permit Number: D12-397 Address: 15255 SUNWOOD BL TUKW Status: APPROVED Suite No: Applied Date: 12/24/2012 Applicant: SUNWOOD CONDOS Issue Date: Receipt No.: R13 -00093 Initials: WER User ID: 1655 Payment Amount: $283.30 Payment Date: 01/08/2013 02:20 PM Balance: $0.00 Payee: DEJAY RICKARD TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 07834G ACCOUNT ITEM LIST: Description 283.30 Account Code Current Pmts BUILDING - RES STATE BUILDING SURCHARGE 000.322.100 278.80 640.237.114 4.50 Total: $283.30 tint. Ppraint -OR Printpri• M- nR -7n11 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 8141400000 Permit Number: D12-397 Address: 15100 SUNWOOD BL TUKW Status: PENDING Suite No: Applied Date: 12/24/2012 Applicant: SUNWOOD CONDOS Issue Date: Receipt No.: R12 -03365 Payment Amount: $181.22 Initials: JEM Payment Date: 12/24/2012 11:43 AM User ID: 1165 Balance: $283.30 Payee: ROBERT D YOUNG TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 297683 ACCOUNT ITEM LIST: Description 181.22 Account Code Current Pmts PLAN CHECK - RES 000.345.830 181.22 Total: $181.22 rinr. RPr..Pint -OR PrintMrt• 12 -24 -2(112 INSPECTION RECORD Retain a copy with permit INS ECTION NO. PERMIT NO. . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - 3670.\\' Permit Inspection Request Line (206) 431 -2451 7 Project: SLIQUJevh 001,10‹ Type of Inspection: t--'1eJA t Address: 1`2.55, S2tAll+.iOO C. QImo. Date Called: . . . Special Instructions: Date Wanted:. 1- 3 1 _ 17 m. p.m. Requester: Phone N o: Q '` P-040 -77cS .(9 /qy 2.Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: 'crw+41t -(P JI. , Ar A j {�fnspecta : Date: Imo-- / ` 1 11 II�LPECTION FEE REQUIR D. Prior to ne _t inspection, fee must be phi at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 4 INSPECTION RECORD' Retain a copy with permit 12 INSPECTION NO. tPERMIT NO. CITY OF TUKWILA BUILDING DIVISION . • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ' (206) 431 - 3670. -' Permit Inspection Request Line (206) 431 -2451 • Project: 3 &/N WOO,) C45 33 Type Inspection:1 -.- r A it,t, Ai Ad1 2,; 3 S U , I��O� Date Called: • Sp cial Instructions: Date Wanted:/ f — 0 S— I ‘..4.01- PAL Requester: Phone � - ?1tO �i p '^I Approved per applicable codes. Corrections required prior to approval. COMMENTS: ,(( fki4. 4 1 Inspec -tor: Date: r +' 3 • R(`SPECTION FEE REQ IRED. Prior toiext inspection. fee must be paid t 6300 Southcenter Blvd., Suite 100. Call to schedule' reinspection. r. • ws --ApW INSPECTION RECORD 12,--.361V Retain a copy with permi INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G� 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro ct: JkJ vor3 6.-a40 4.s w Typ of Inspection: ri -640 AS F, Address: 1 S 1—S , SunwaoTj Date Called: Special Instructions: Date Wanted: . — 1 - rp- i3-..p.. p.m.m. Requester: Phone No: c Approved per applicable codes. Corrections required prior to approval. COMMENTS: IY--.V.A4) (---0 A D i- -.'- ' a "-__S- 1 J> Z--- i■-1 . n. Co --, i Inspectidr: Date: + ' t FEE REQUIRED. Priof to next inspection, fee must be REINSPECTION UMR NOVA 23316 NE Redmond -Fall City Road #608 Redmond, WA 98053 RECEIVED JAN 15 2013 BUILDING DEPARTMENT 1)12 —397 Request For Information [)ate Create 1/7/2013 Sunwood Condominiums 15100 Sunwood Blvd. Tukwilla, WA 98188 Project #: 12 -168 Clannadh, Inc. Answer Company: J2 Building Consultants Rudy Young 3400 188th ST SW; Ste 302 Lynnwood, WA 98037 Tel: (425) 223 -4101 Fax: Author Company: Carl Hauenstein Clannadh, Inc. 23316 NE Red -Fall City Road #608 Redmond, WA 98053 Tel: (206) 427 -3013 Fax: (425) 868 -7380 Co- Respondent ; • i ;subject' g i Additional Decay at Second deck of Primary invest. IRFI Question Question #1 The beam of the deck has been removed due to the amount of decay. The beam pockets at the end walls have only a 1" to 1.5" vertical support . It is our understanding that minimum bearing Is 3" for structural bearing. We need direction for what we should do here. 9Su6contracti�riRFl INfntier ipli es Structural ate, Engineering qed 32/ uir 0/12 FAntAier: 5" t)(!3 r r /1 I.t "LLr.. -IA Lon r..c.[ -( y2 `•� i'C.C.XJi'r'rr',•C.._ 1,(.. , °l n p' L /Or . f I Yt.( /' aGC!. 5-cv /144,r-tr -J fAeirC`ais. /rMi7Y ez I l6,5 i`5 r'u.e,.0 / cl Printed On: 1/8/2013 ate�A'hswered (/1 ;7 /I_i Page 1 Project: Subject: Date: S\...A kA.) e)01. R Z *// %1‘o113 El Field Report By: ?P Meedng Notes [J Teleconference 11111 11111 BUILDING CONSULTANTS INC. Washington Offices 3400 188th St SW, Ste 302 Lynnwood, Washington 98037 T: (42.5) 774 -5600 / F: (425) 774 -5661 Oregon Offices 112 SW Pennoyer St, 2nd Floor Portland, Oregon 97239 T: (503) 546 -8212 / F: (503) 546 -8219 Hawaii Offical 500 Ala Moana Blvd, Ste 400 Honolulu, Hawaii 96813 T: (808) 672.2080 / F: (808) 672-2081 Testing Lab & Training Gtr, 2615 W. Casino Rd, Ste 6 -E Everett, Washington 98204 T: (425) 774.5600 GENERAL CONSTRUCTION NOTES 1) THESE DRAWINGS DESCRIBE GENERAL REQUIREMENTS FOR WEATHERIZATION DETAILS. REFER TO ARCHITECTURAL DRAWINGS FOR CLADDING TYPES, COLORS, WALL ASSEMBLIES, AND THERMAL RESISTANCE VALUES REQUIRED. REFER TO STRUCTURAL ENGINEERING DOCUMENTS FOR ANY STRUCTURAL CONCRETE, STEEL OR WOOD FRAMING REQUIREMENTS. 2) ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES, STANDARDS, AND MANUFACTURER'S INSTRUCTIONS. REPORT ANY DISCREPANCIES TO ARCHITECT. 3) CONTRACTOR SHALL VERIFY CONDITIONS ON SITE BEFORE BEGINNING WORK AND REPORT ANY DISCREPANCIES TO ARCHITECT. 4) THE CONTRACTOR SHALL BE FAMILIAR w/ THESE DRAWINGS AND DETAILS AND SHALL ENSURE THAT THEIR WORKERS HAVE THE EXPERIENCE, TRAINING AND SKILLS REQUIRED TO EXECUTE THE WORK. 5) SUBMIT REQUEST FOR INFORMATION (RFI) TO THE ARCHITECT. SUBMIT ANY CHANGES IN THE CONTRACT VALUE IN THE FORM OF A CHANGE ORDER PROPOSAL TO THE CONSTRUCTION MANAGER.. 6) COORDINATE ALL CONSTRUCTION ACTIVITY WITH THE OWNERS REPRESENTATIVE(S). PROVIDE SPECIAL CONSIDERATION FOR NOISY OPERATIONS, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES. PROTECT LANDSCAPING & FIXTURES. 7) DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER IMAGES AND ILLUTRATIONS. 8) ALL LUMBER SIZES INDICATED ARE NOMINAL UNLESS DIMENSIONED OR NOTED OTHERWISE. 9) EXTERIOR SHEATHING & FRAMING REPAIRS SHALL REQUIRE INSPECTIONS. COORDINATE INSPECTIONS WITH BUILDING OFFICIALS PRIOR TO COVERING. 10) DO NOT INSTALL DAMAGED OR DEFECTIVE MATERIAL(S). 11) LAP WEATHER RESISTANT BARRIER OVER VERTICAL FLASHING A MIN OF 4 ". UNLESS NOTED OTHERWISE. 12) REFER TO MATERIAL DATA SHEETS AND MANUFACTURER'S INSTRUCTIONS BEFORE INSTALLING ANY NEW MATERIALS 13) PROVIDE; a) 2" MIN CLEAR B ALL CLADDING TO HORIZONTAL HARD SURFACES B) 6" MIN CLEAR @ ALL FRAMING TO FINISH GRADE 14) EXPOSED FASTENERS SHALL BE SEALED OR GASKETED. INSTALL & LOCATE ALL FASTENERS PER SMACNA. 15) HEM METAL FLASHING DRIP EDGES, TYPICAL. PROVIDE FULLY SOLDERED JOINTS IN SECTIONS OF FLASHING JOINED TOGETHER AS INDICATED ON DRAWINGS. 16) PROVIDE GALVANIC SEPARATION MATERIAL BETWEEN DISSIMILAR METALS. 17) NOTIFY THE ARCHITECT AND /OR CONSTRUCTION MANAGER OF ANY PREVIOUSLY UNDISCOVERED DAMAGE, DEFICIENCIES OR THREATS THAT COMPROMISE THE FIRE AND /OR LIFE SAFETY OF THE BUILDING OCCUPANTS. 18) CONTRACTOR SHALL PROMPTLY REPAIR ANY ACCIDENTAL DAMAGE AT NO ADDITIONAL COST TO THE OWNER. 19) CONTRACTOR SHALL REMOVE DEBRIS AND TRASH FROM THE SITE IMMEDIATELY. DISPOSE OF LEGALLY. KEEP THE BUILDING AND GROUNDS CLEAN AND FREE OF REFUSE AT ALL TIMES. 20) CONTRACTOR SHALL DOCUMENT PRE - EXISTING CONDITIONS FOR REFERENCING DURING NEW CONSTRUCTION. 21) CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR CONSTRUCTION MANAGER OF ANY DISCOVERED MOLD DURING THE COURSE OF WORK. ALL DISCOVERED MOLD SHALL BE TREATED VIA THE GENERIC MOLD ABATEMENT PROTOCOL OUTLINED IN SECTION NUMBER 02 050 DEMOLITI• .. .._! „OISTU PROJECT DESCRIPTION The following is a brief summary of the targeted scope of repair for Sunwood Condominiums, located at 15100 Sunwood Blvd in Tukwila, WA. This scope is based on observations during a J2 investigation of two exploratory opening areas as performed by Clannadh construction on October 11, 2012. Subsequently work has been performed by Clannadh Constuction to repair the moisture damaged framing materials. This document is intended to provide information related to work performed and to be performed, for the purpose of obtaining a construdion permit. This Scope of Repair is meant to provide a general understanding of the work, and to allow the General Contractor to fulfill repair requirements. The repair scope is limited to the specific areas described. It does not address unforeseen conditions that may exist on this condominium complex. During construction, the Contractor shall provide submittals, RFI's change order proposals and pay applications as typically required during the course of work of this project. SCOPE OF REPAIR DESCRIPTION: Scope of work is limited to two specific areas of Building A: Area 1 °South Deck" and Area 2 "West Wall`. These areas were pre - selected for exploratory openings. At both areas, moisture damage was observed after removal of a portion of the stucco cladding. Following is a general description of the repair scope to accompany the drawing set attached, GENERAL WATERPROOFING NOTES 1) ALL FLASHINGS SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE WALL OR TO REDIRECT IT TO THE EXTERIOR. 2) ALL WALL AND ROOF PENETRATIONS SHALL BE TARGET FLASHED. 3) ALL WEATHER RESISTIVE BARRIERS SHALL HAVE POSITIVE LAPPING (SHINGLE STYLE) WHEN INSTALLED. LAPPING AND SEALING OF SEAMS AND JOINTS SHALL BE BY MANUFACTURER'S REQUIREMENTS. 4) ALL BUILDING INTERFACES SHALL BE FLASHED TO PREVENT MOISTURE FROM ENTERING THE WALL. 5) ALL HORIZONTAL HARD SURFACES SHALL HAVE ADEQUATE SLOPING FOR DRAINAGE. 6) PROVIDE PRODUCT SUBMITTALS FOR REVIEW BY J2 PRIOR TO INSTALLATION. PROJECT TEAM OWNER SUNWOOD HOA ARCHITECT J2 BUILDING CONSULTANTS, IN CONTRACTOR CLANNADH CONSTRUCTION INDEX TO DRAWINGS A0.0 t~ a A0.1 ;t A0.1 A1• .1 • A1.2 A1.3 A1.4 COVER SHEET / GENERAL NOTES SCOPE OF REPAIR DESCRIPTIONS SCOPE OF REPAIR PHOTOS NOT USED (STUCCO REMOVED) SADDLE FLASHING DETAIL DECK DETAILS DECK DETAILS RhL∎tiVt:.l CITY OF TUKW . _ DEC 242012 • R .:...... • t ` - .. 'tom • t't • VICINITY MAP ::x:1)1 /1/4 R-j'- / ,z•L./ ,) e 44'o', 6%, /3L,,'/&l.) j 0/0/ )-4 i ch ,• co,, l fti 1 Lt.-;44 CL-tcs i s 444,1 l�, /J /(, ,L No change t of _fi=ts:. cod may! t4f' at}zzQ aft x BUILDING CONSULTANTS INC. 3400 - 188th St SW Ste 302 Lynnwood, Washington 98037 Tel 425.774.5600 Fax 425.774.5661 www..J2Consultant.com Copplght 0 2011 J2 Bulldog Consultants. 0. ,1 . NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING DIMENSIONS, ELEVATION, PLAN, SIDING, WINDOW AND DOOR QUANTITIES. 2. DRAWINGS ARE DIAGRAMATIC ONLY, AND ARE NOT TO BE USED FOR TAKE OFF QUANTITIES. 6401 REGISTERED ARCHITECT STATE OF WASHINGTON REVIEWED OR- C ®pg? ' • i,, IAN CE PERMIT SET SUNWOOD Condominiums Building Exterior Repairs 15100 Sunwood Blvd. Tukwila, WA ar.• COVER SHEET Scale: As Noted 12/▪ 17/2012 loses ai•• Karts. A -0.0 SCOPE OF REPAIR DESCRIPTION; Scope of work is limited to two specific areas of Building A: Area 1 °South Deck' and Area 2 "West Wall ". These areas were pre - selected for exploratory openings. At both areas, moisture damage was observed after removal of a portion of the stucco cladding. Following is a general description of the repair scope to accompany the drawing set attached. Area 1: South Deck At this south deck structure, we observed significant moisture and area of wood rot in the structural elements behind the stucco cladding. We observed inadequate structural support of the post to floor construction, and deficient flashing installation around the post connections - which appears to be the cause of increased moisture intrusion at the post structures. We also observed heavily stained base of stucco wall and a deteriorated exterior storage room door at this deck location. The posts and deck fleshings had been previously repaired; however with the amount of damage observed, J2 recommends remediation to prevent further damage. Two options for repair scenarios shall be priced as follows: NOT SELECTED 12/01 /1 2 Option 1B includes removal of entire existing guardrail system and replacing with new aluminum picket railing. Work includes replacement of heavily damaged storage door and trim at the third floor deck. Option 1B - Replace with new aluminum picket railing: 1 Remove and dispose of entire existing guardrail system and remaining stucco and deck flashing along deck floor line in area described in photo. At areas of removed wall, chip back 4.6" of existing stucco to retain a minimum of 4' of existing WRB to allow for new WRB integration. Retain minimum of 2.4" of wire lath to allow for new wire lath integration. 2. Replace damaged support posts. Provide new structural posts and steel connectors, as described in drawings. 3. Treat all wood areas adjacent to moisture damaged wood with Bor- a-Care treatment 4. Verify if additional joists are needed at east side of deck framing. If needed, remove portion of stucco soffit and install additional joists to double up the parallel joists. Include in price time to investigate existing framing and cost to add joists.. If additional joists are not needed, this scope of work would be deducted by change order. 5. Confirm deck is sloped adequately. Install new metal flashing at deck edges, intersections and around corner posts in preparation for new deck coating. 6. Install 24 gauge pre-finished sheet metals shall be installed over new WRB at all deck edges and at new column pports. Note: this Option omits stucco from the scope of work at the deck edges and corner post. 7. Prepare existing deck surface as recommended by deck waterproofing manufacturer. Deck coating to extend into storage room floor. Install mock up of new deck coating and perform w llles io.:on iuu -- compatibility and adhesion to existing deck membrane. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 3 2013 8. Install new tight knot cedar 9. Install new polyurethane Deck Coating. 10. Integrate new Grade D WR8 and install new lath and stucco to match existing finishes. 1 1.Install new Aluminum Picket Railing. 1 2.After stucco has cured (2 weeks), dean adjacent wall surfaces and apply professional for stucco finish to match existing adjacent color at areas where stucco has been patch ade reeltit0Ifikwila BUILDING DIVISION 13. Storage door replacement: o. Remove and replace storage door, exterior trim, and portions of stucco to allow for head and jamb flashing integration. b. Install new 5/4" primed cedar trim and drip edge head flashing - integrating new Self Adhered Fleshings with existing WRB. c. Install new fiberglass door as noted in products section below. Area 2: West Wall At this west wall location, we observed moisture intrusion and wood rot behind the stucco cladding. We also observed reverse slope at the deck edge and stucco installed too close fo the deck surface. The deficient installation at this intersection of 4 different surfaces appears to be the cause of the observed rot damage. Due to the evidence of continued water intrusion at this location, J2 recommends remediation to prevent further damage and repair costs. A general description of the repair follows: 1. Remove stucco at areas of exploratory openings and along base of wall at deck (about 5'). At stopping points, chip back 46° of existing stucco to retain a minimum of 4 of existing WRB to allow for new WRB integration. Retain minimum of 24" of wire loth to allow for new wire lath intearation. 2. Remove existing deck flashing and prepared deck surface for new Deck Coating membrane, 3. Remove all moisture damage materials from construction. At this location we observed an area of plywood approximately 6" x 6' along with some moist 2x material that will require some chiseling to remove all soft spots. 4. Treat all wood areas adjacent to moisture damaged wood with Bore -Care treatment 5. Replace plywood and framing as needed to match existing adjacent surfaces. 6. Confirm deck is sloped adequately. Grind surface os necessary to ensure positive sloping. Install new metal flashing at deck edges and around intersections in preparation for new polyurethane deck coating. 7. Prepare existing deck surface as recommended by deck waterproofing manufacturer. Install mock up of new deck coating and perform pull-test to confirm compatibility and adhesion to existing deck membrane. 8. Install new polyurethane Deck Coating. 9. At Post and Deck Edges: Install Fiber cement panels with metal ends over new WRB (Tyvek, Vaproshild, and /or Wet - Flash) 10. At Stucco Areas: Integrate new Grade D WRB and install new lath and stucco to match existing finishes. 11. After stucco has cured (2 weeks }, clean adjacent wall surfaces and apply professional grade acrylic paint for stucco finish to match existing adjacent color at areas where stucco has been patched. Contingency for additional Repair 1. Contractor shall include 10% contingency for additional repairs as discovered during remediation. Acoeotable Produds 1. Deck Canting: TREMCO 350/351, 351 Polyurethane Deck Coring, Poofic Polymeaa ci- 5000 X2'Polyvreihone Deck Coating System, or aASF Sonogaurd. 2. Bose WRB: Tyvek Commercial Wrap or Vaproshield WrapShield , Prosoco Wei-Flash rat complex inlersedfares or approved equal_ 3. Grade "D"' WRB: Fortifiber TI'v v5uper,jumbv rex60Mrnule-oroppraved equal. 4. Butyl SAF: Tyvek "RexWrap" (64 mit, Tyvek 'Skalghi Rosh" (30 mil), Stucco-Flex •'Them sh' (1842 ml4 Grace Vyoar Pm (14 moll -or approved equal. 5. Aluminum Roiatnrg: Roitvsorla, 'Laubtta Top ftkel Rat 'ng canted 86&RAf1WOWS, setht irgath net; Or approved equal. 6. Fiberglass Door_ Thermo-Du flat panel with jambs, hinges, weather stripping, sill sweep, and hardware far exterior passage set. Or approved equal 7. Bor-A-Care: Fungicide/hlsertikide wood treatment for penetrating wood pratectran, BUILDING CONSULTANTS INC. 3400 - 1886 St SW Ste 302 Lynnwood, Washington 98037 Tel 425.774.5600 Fax 425.774.5661 www..12Consultonts.com CcpYt1Gt0 0 2011 J2 BuBQm9 CaIJtm.b. Inc. *2 is reserved. NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING DIMENSIONS, ELEVATION, PLAN, SIDING, WINDOW AND DOOR QUANTITIES. 2. DRAWINGS ARE DIAGRAMAT1C ONLY, AND ARE NOT TO BE USED FOR TAKE OFF QUANTITIES. 6401 REGISTERED ARCHITECT revisions Note Date Description PERMIT SET K�l.ti v CITY OF Tit Ktrl 51 A .. rn� S T xCrioonr d UEC 2U12 15100 Sunwood Blvdairs PERMFr CENTERu ila, wA Shost 71. SCOPE OF WORK DESCRIPTION Scale: As Noted 12/17/2012 J. Marto- 7582 BMW A -0.1 Add Simpson ISTA -18 straps both sides of post to deck framing Upgrade existing post anchor Simpson AB O6 with 5/8 °x 4" expoxy set all tread Photo 3: Area 1 HO Mbasiure of Post EXISTING CORRODED POST BASE REMOVED. NEW SIMPSON AB66 INSTALLED WITH EPDXY SET 5/8" X 4" ALL - THREAD ATTACHED TO EXISTING CONCRETE POST BASE Photo 5: Area 1 Poch deck woterpma/ing dehctent insEalioEign INSTALLATION OF EPDXY SET 5/8" ALL THREAD BOLT INSTALLATION OF SIMPSON BUILDING CONSULTANTS INC. 3400 - 1 88th St SW Ste 302 Lynnwood, Washington 98037 Tel 425.774.5600 Fax 425.774.5661 www.J2Consultants.com Ce,olgty 0 2011 J2 Building Consultants. toe All rights 'emerald. 6401 REGISTERED ARCHITECT RUDY YOUNG STATE OF WASHINGTON NOTES: 1. WED FOR OMPLIANCE APPROVED JAN 0 3 2013 B 66 City of Tukwila BUILDING DIVISIO CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING DIMENSIONS, ELEVATION, PLAN, SIDING, WINDOW AND DOOR QUANTITIES. DRAWINGS ARE DIAGRAMATIC ONLY. AND ARE NOT TO BE USED FOR TAKE OFF QUANTITIES. re Note isions Date Description 12/17/12 Permit Submittal POST CAP LSTA 18 INSTALLATION PHOTO MID LEVEL LSTA 18 EXISTING POST BASE Nb.,,i�: is t :,.1 _ CITY OF T��. ", DEC 2 2012 PERMIT SET PERMIT CENTER POST BASE INSTALL PHOTO 1 POST BASE INSTALL PHOTO 2, SUNWOOD Condominiums Building Exterior Repairs 15100 Sunwood Blvd. Tukwila, WA roe SCOPE OF WORK PHOTOS Scale: As Noted 12/1772012 7582 A -0.2 PLANNING APPROVED • No changes can be made to these plans without approval from the Planning Division of DCD Approved By:, J Date:, of n l', / j; PRE FINISHED METAL CAP FLASHING TO MATCH EXISTING WITH STANDING SEAMS AND SLOPED TO DRAIN TYPICALLY. 24 GA. GALV SADDLE, FULLY SOLDER ALL JOINTS SEALANT BEADS WRB LAPPED OVER VERTICAL LEG OF SADDLE PRE FININSHED METAL COPING TO COVER FINISH STUCCO WALL ASSEMBLIES. PROVIDE BACKER ROD AND SEALANT AT VERTICALS WITH DRAINAGE AT STUCCO TO COPING TOP SET COPING IN 2 BEADS OF SEALANT SET SADDLE OVER SAF SADDLE FLASHING (UNDER COPING) K�!oty� CITY OFT"N1'" DEC 2Lt 2012 PERMIT CENTER DECK -TO -WALL SADDLE FL SHING- OPTION 1A SCALE: NTS BUILDING CONSULTANTS INC. 3400 • 1 88th St SW Ste 302 Lynnwood, Washington 98037 Tel 425.774.5600 Fax 425.774.5661 www.J2Consultants.com Copylghl 0 2011 J2 Building Consultant. Inc. All rights moved. NOTES: 1. 6401 CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING DIMENSIONS, ELEVATION, PLAN, SIDING, WINDOW AND DOOR QUANTITIES. DRAWINGS ARE DIAGRAMATIC ONLY, AND ARE NOT TO BE USED FOR TAKE OFF QUANTITIES. RARCMTECD RU, 4* UN STATE OF WASHINGTON revisions Note Date Description PERMIT SET SUNWOOD Condominiums Building Exterior Repairs 15100 Sunwood Blvd. Tukwila, WA Sho.t.l, DETAILS Scale: As Noted 12 12/17x2012 IShostMumbr. Ja0 mentor. A1.2 7582 NOTES: 1. DETAIL IS DIAGRAMATIC FOR PRICING ONLY. FINAL LAYOUT SUBJECT TO FIELD VERIFICATION OF EXISTING AND PROPOSED STRUCTURAL CONDITIONS. 2 GUARDRAIL SHALL BE ENGINEERED BY WA STATE ENGINEER PER DEFERRED SUBMITTTAL BY GC. REMOVE EXISTING STUCCO WHERE STUCCO IS LESS THAN 1" TO DECK WRB PRESTRIP BEHIND FLASHING FIELD WRB LAPS METAL FLASHING. SET IN CONT. SEALANT 4" SAF (SELF ADHERED FLASHING) OVER TOP OF METAL, TYP. - CONT. CANT BEAD PER MANUF. REQ. ' - NEW MTL. BASE OF WALL FLASHING W/ 10° OVERBEND TO SIT TIGHT TO DECKING - NEW PEDESTRIAN DECK COATING OVER EXISTING TYPICAL 1/4 ": 12" TYP SLOPE DECK STUCCO STOP ITH WEEPS AT BASE TYPIC 1 "- EXIST JOIST EXIST LEDGER (NO WORK) .t, EXIST STUCCO SOFFIT EXIST SIDING (NO WORK) DECK TO WALL DETAIL -AREA 2 TYPICAL A1.3 SCALE : 3" = 1' -0" NEW PEDESTRIAN DECK COATING 11 7-POWDER COATED AL GUARDRAIL WITH PIC MAXIMUM SPACING TYP. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 3 2013 NR1 EXIST STUCCO SOFFIT 2 z N City of Tukwila DIVISIO NEW PRE FINISHED DECK EDGE METAL, FLUSH / DECK SURFACE, SET IN SEALANT POWDER COATED ALUMINUM SIDE MOUNTED RAILING BRACKET BY RAIL MANUFACTURER NEW FIBERCEMENT PANELS OVER NEW MOISTURE BARRIER OVER FURRING STRIPS AS NEEDED BUILDING CONSULTANTS INC. 3400 - 188th St SW Ste 302 Lynnwood, Washington 98037 Tel 425.774.5600 Fax 425,774.5661 www.J2Consultants.com Cop aigM 0 2111 J2 Building CansWl 00. Inc. M lights . ENGINEERED STAINLESS STEEL FASTENERS PER RAIL MANUFACTURER. PRE -DRILL AND FILL WITH SEALANT BEFORE FASTENING TYPICAL EXISTING WOOD STRUCTURE. GC TO CONFIRM STRUCTURAL CONDITIONS . MINIMUM OF 2 JOISTS AT EDGES REQUIRED. CORROSION RESISTANT FASTENERS TYP TYP. DRIP EDGE AT BASE OF FIBER CEMENT DECK RAILING ATTACHMENT - OPTION 1B A1.3 SCALE : 3" = 1' -0" CITY OF Tzl +''t DEC 2 « 2012 NOTES: 1.. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING DIMENSIONS, . ELEVATION, PLAN, SIDING, WINDOW AND DOOR QUANTITIES. 2. DRAWINGS ARE DIAGRAMATIC ONLY, AND ARE NOT TO BE USED FOR TAKE OFF QUANTITIES. revisions Note Date Description 12/17112 Permit Submittal PERMIT SET SUNWOOD Condominiums Building Exterior Repairs 15100 Sunwood Blvd. Tukwila, WA si.w nr PERMIT CENTER DETAILS Scale: As Noted p— au.n"unC". 12/17(2012 Job " 7582 A1.3 STEP 1 • i/ . \` \ / / • X • WRB OVER TOP 6 "x 6 "x 6" GALV. SADDLE FLASHING SET IN SEALANT PLANE DECK TO RECEIVE METALS SADDLE FLASHING LAPS WRB DECK SUB FASCIA, WRAP W/ WRB METAL BASE TO WALL FLASHING DIVERTER (BUILT UP BASE COAT OR METAL TAB) 1 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 3 2013 City of Tukwila BUILDING DIVISION STEP 2: INSTALL PREFINISHED MTL. DECK EDGE METAL FLUSH WITH DECK SURFACE, LAPS OVER FASCIA TRIM STEP 1: INSTALL FASCIA TRIM BOARDS STEP 4 DECK -TO -WALL SADDLE FLASHING A1.4/ SCALE: NTS ELASTOMERIC DECK COATING o 000000 0 000000 BUILDING CONSULTANTS INC. 3400 - 1 88th St SW Ste 302 Lynnwood, Washington 98037 Tel 425.774.5600 Fax 425.774.5661 www.J2Consultants .com Copyright ® 2011 12 Building Coneu9znls... Ino. 2 righlo reserved. NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING DIMENSIONS, ELEVATION, PLAN, SIDING, WINDOW AND DOOR QUANTITIES, 2. DRAWINGS ARE DIAGRAMATIC ONLY, AND ARE NOT TO BE USED FOR TAKE OFF QUANTITIES. �Cttidv rt CITYOfT iK;•�S DEC 2 4 2012 PERMIT CENTER revisions Note Date Description PERMIT SET Roma ,,. SUNWOOD Condominiums Building Exterior Repairs 15100 Sunwood Blvd. Tukwila, WA DETAILS Scale: As Noted Oar 12/17/2012 Jab 7582 A1.4 • el Jennifer Marshall From: Jennifer Marshall Sent: Monday, December 24, 2012 4:31 PM To: 'RUDYY @J2CONSULTANTS.COM' Subject: D12 -397, Sunwood Condos Good afternoon Rudy, I wanted to keep you informed as to some information I added /adjusted on your permit application. The address for Building A is 15255 Sunwood Blvd and consequently I updated that on the permit application. I also added parcel numbers for each of the units and they are as follows: A13: 814140 -0060 A23: 814140 -0090 A33: 814140 -0160 A36: 814140 -0190 )ennifer Marshall Permit Technician, City of Tukwila T: 206 431 -3670, F: 206 431 -3665 jennifer .marshallkatukwilawa.gov 1 • ! ,viz -377 Dave Larson From: Rudy Young <RudyY @j2consultants.com> Sent: Friday, December 28, 2012 4:09 PM To: Dave Larson Cc: tom.g.kunza @boeing.com; Jorja Burtis; Carl Hauenstein Subject: D12 -397 Sunwood Condominiums RCW 64.55 Compliance Hi Dave, Thank you for speaking with me this afternoon, concerning this deck repair project at Sunwood Condominiums. As discussed the work involved will not exceed 5% of the assessed value of the Sunwood Condominium complex; therefore, it is not subject to compliance with RCW 64.55 requirements for rehabilitation of a multi- family project. We will not be issuing a letter of compliance per RCW 64.55.020 "building permit application - submission of design documents" Although we will not be submitting a letter with the design documents, we will be providing a letter at the conclusion of the work. This letter will note that we have, as Architect of record, observed the work during the course of construction. This letter will note that the installation is consistent with the architectural documents issued to date and will provide documentation of any changes made during the course of construction. We are looking forward to receiving a permit for construction of the remaining work. Please feel free to contact me if there are any further questions. Sincerely, Rudy D. Young, AIA NCARB Architect, WA CA J2 BUILDING CONSULTANTS, INC. RudyY @J2Consultants.com OFF 425.774.5600 I DAR 425.223.4101 I CELL 206.914.1608 Cc: Jorja Burtis and Tom Kunza - Sunwood Home Owners Association Carl Hauensteing - Project Manager Clannadh Construction northwest HARVEST omoorg During the month of December, 12 Building Consultants will be donating 1% of all new contracts to Northwest Harvest. Join us in the fight to end hunger in our community. RICENED CM/ or (DEC 2 8 20121 1 ERMIT COORD COMA PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -397 DATE: 12/24/12 PROJECT NAME: SUNWOOD CONDOMINIUMS SITE ADDRESS: 15255 SUNWOOD BL: A13;_ 23, 33, & 36 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 11f "-& Building Division IN JJs AM_ iiy7-1� Public Works �J Fire Prevention Structural Q1(v) ftv I1- ,∎1- Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12/27/12 Complete 1)t, Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only. INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 01/22/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name CLANNADH LLC UBI No. 602995549 Phone 4258989185 Status Active Address 23316 Ne Red -Fall City Rd #608 License No. CLANNL "909DW Suite /Apt. License Type Construction Contractor City Redmond Effective Date 3/16/2010 State WA Expiration Date 4/9/2014 Zip 98053 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status CLANNCL9350F CLANNADH CONSTRUCTION LLC Construction Contractor Siding Unused 9/6/2007 9/6/2009 Expired CLANNDL9400J CLANNADH DEVELOPMENT LLC Construction Contractor General Unused 9/11/2006 9/11/2010 Expired CLANNE1950CS CLANNADH ENTERPRISES INC Construction Contractor General Unused 2/10/2005 2/10/2009 Re Licensed CLANNE *965MW CLANNADH ENTERPRISES Construction Contractor General Unused 7/16/2004 7/16/2006 Re- Re- Licensed Business Owner Information Name Role Effective Date Expiration Date MULLEN, ALAN J Partner /Member 03/16/2010 Amount Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 American Contractors Indem CO 100115615 03/02/2010 Until Cancelled $12,000.00 03/16/2010 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 Ccoottsdale Ins TBD 03/01/2012 03/01/2013 $1,000,000.00 03/01/2012 3 Preferred Contractors Ins Co PC7454402 03/01/2011 03/01/2012 $5,000,000.00 03/10/2011 2 Preferred Contractors Ins Co PC7454402 03/01/2011 03/01/2012 $5,000,000.00 03 /07/2011 1 Preferred Contractors Ins Co PC74544 03/01/2010 03/01/2011 $5,000,000.00 03/16/2010 Summons /Complaint Information Cause County Complaint Judgment Status Payment Paid By KING 10 -2- 43110 -1SEA Date: 12/16/2010 https: // fortress .wa.gov /lni/bbip /Print.aspx Date: Open Date: 01/08/2013