Loading...
HomeMy WebLinkAboutPermit EL12-0211 - SEGALE PROPERTIES - VACANT SPACESEGALE VACANT SPACE 300 ANDOVER PK W EL12-021 1 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049001 Address: 300 ANDOVER PK W TUKW Project Name: SEGALE VACANT SPACE ELECTRICAL PERMIT Permit Number: EL12 -0211 Issue Date: 03/19/2012 Permit Expires On: 09/15/2012 Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA WA Contact Person: Name: STEVE NELSON Address: PO BOX 88028 , TUKWILA WA Contractor: Name: R -C TRUE LINE CORPORATION Address: 15321 105 AV CT E , PUYALLUP WA Contractor License No: RCTRULC038QG Phone: 206 575 -2000 Phone: 253 845 -8775 Expiration Date: 11/07/2013 DESCRIPTION OF WORK: SUITE 450: INSTALL NEW 200 AMP METERED SERVICE FROM ELECTRICAL SERVICE ROOM TO NEW TENANT SUITE. ADD 2 INCH CONDUIT FROM ELECTRICAL SERVICE TO TENANT SPACE FOR TELEPHONE SERVICE. Value of Electrical: NRES: $22,150.00 RES: $0.00 Fees Collected: Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: $610.13 2008 Date:_ le` L& I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th- ,perform ap9e of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL12 -0211 Printed: 03 -19 -2012 41 PERMIT CONDITIONS • Permit No. EL 12 -0211 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -0211 Printed: 03 -19 -2012 1 CITY OF TUKWIIA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.gov • Electrical Permit No. L� D24 Project No. Date Application Accepted: Date Application Expires: Oh�ole I do 12 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 300 Andover Park West Tenant Name: Segale vacant Space King Co Assessor's Tax No.: 262304 9001 Suite Number: 450 Floor: 1 PROPERTY OWNER Name: Steve Nelson Name: Segale Properties LLC Address: PO Box 88028 Address: PO Box 88028 City: Tukwila State: WA City: Tukwila State: WA Zip: 98138 CONTACT PERSON — person receiving all project communication Name: Steve Nelson Address: 15321 105th Ave Crt East Address: PO Box 88028 Phone: (253) 845 -8875 Fax: (253) 845 -4652 City: Tukwila State: WA Zip: 98138 Phone: (206) 575 -2000 Fax: (206) 575 -1662 Email: snelson @segaleproperties.com New Tenant: ❑ Yes j .. No ELECTRICAL CONTRACTOR INFORMATION Company Name: R -C Trueline Address: 15321 105th Ave Crt East City: Puyallup State: WA Zip: 98374 Phone: (253) 845 -8875 Fax: (253) 845 -4652 Contr Reg No.: RCTRUC038QC Exp Date: 11/07/2013 Tukwila Business License No.: BUS - 0993053 Valuation of Project (contractor's bid price): $ 22,150 Scope of Work (please provide detailed information): Install new 200 amp metered service from electrical service room to new tenant suite 450. Add 2" conduit from electrical service room to tenant space for telephone service. Will service be altered? ® Yes ❑ No Adding more than 50 amps? IZ Yes ❑ No Type of Use: Mercantile Tvpe of work: ❑ New ❑ Addition 21 Service Change ❑ Remodel 21 Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served bv: Puget Sound Energy ❑ Seattle City Light H: \4pplicationsWorms- Applications On Line \201 1 Applications\Electrical Permit Application Revised 8 -9-1 l.docx Revised: August 2011 bh Page 1 of 2 i •R RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $152.85 $81.90 ea $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added /altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added /altered without service change $54.60 (up to 5 circuits) ❑ Circuits added /altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signatur --Fp9„4_ Date: 03/02/2012 Print Name: Steven R. Nelson Day Telephone: (206) 575 -2000 Mailing Address: PO Box 88028 Tukwila WA 98138 City Hakpplications\Forms- Applications On Line \2011 ApplicationslElectrical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh State Zip Page 2 of 2 Cilf of Tukwila. 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT Copy Reprinted on 03 -07 -2012 at 09:01:51 03/07/2012 RECEIPT NO: R12 -00927 Initials: JEM Payment Date: 03/06/2012 User ID: 1165 Total Payment: 3,225.88 Payee: SEGALE PROPERTIES LLC SET ID: S000001712 SET NAME: Temporary Set SET TRANSACTIONS: Set Member Amount D12 -072 1,460.87 EL12 -0211 610.13 PG12 -038 154.88 PW12 -021 500.00 PW12 -022 500.00 TOTAL: 1,460.87 TRANSACTION LIST: Type Method Description Amount Payment Check 2107 3,225.88 TOTAL: 3,225.88 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES GAS - NONRES PLAN CHECK - NONRES PLUMBING - NONRES PW BASE APPLICATION FEE PW PERMIT /INSPECTION FEE PW PLAN REVIEW STATE BUILDING SURCHARGE 000.322.100 882.65 000.322.101.00.0 488.10 000.345.832.00.0 122.03 000.322.103.00.0 63.00 000.345.830 604.70 000.322.103.00.0 60.90 000.322.100 500.00 000.342.400 250.00 000.345.830 250.00 640.237.114 4.50 TOTAL: 3,225.88 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 R. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: C ,41 d ,e tATA-41- Type of Inspection: .ter co Address: r Date Called: Special In (ructions: Date Wanted:. r , a.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 1, J 6t'1 Date: cyglof/t? n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 642.- f PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 , (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: r � � •,G v + ' t Type of Inspection: O 0 3 00 M / Date Called: Special Instructions: Date Wanted:. 0 i1 a.m. Requester: fl Phone No: EjApproved per applicable codes. a Corrections required prior to approval. COMMENTS: .e lnlAiit/Si/ iaAkIDoi Inspector: ` 01 (Date: ©! r 1/12. ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD i,� 0� Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 Z. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Projects _ ' ij Type of Inspection: 7o0 Address: V L( Date Called: ' Special Instructions: �i� ` �0� Date Wanted:. m. Requester: ��Q�� Phone No: i -� , j 53 7`�o DApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: eikkctizi tAik or Pf 916c Inspector: 16411 "—I REINSPECTION FEE REQUIRED. rior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date:O� 12, ,2- HERMIT COORS COP* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0211 PROJECT NAME: SEGALE VACANT SPACE SITE ADDRESS: 300 ANDOVER PK W, STE 450 DATE: 03/06/12 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: B Ild'ng Division Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03/08/12 Complete Incomplete ❑ Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: DUE DATE: 04 /05/12 Approved with Conditions k- Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 02/29/12 Contractors or Tradespeople P ter Friendly Page • Electrical Contractor A business licensed by L&I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company R -C TRUE LINE CORPORATION 2538458875 15321 105Th Ave Ct E Puyallup WA 98374 Pierce Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601828382 Active RCTRULC038QG Electrical Contractor 11/7/1997 11/7/2013 General Unused ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TRUEL "035KHTRUE LINE Electrical Contractor General Unused 5/8/1997 5/8/1999 Archived Master Electrician INFORMATION License RAU*RRH967C3 Name RAU, ROBERT H Status Active Business Owner Information Name Role Effective Date Expiration Date RAU, ROBERT H Violation Amount 01/01/1980 8/10/2009 RAU, CARLOTTA ELECTRICAL CITATION 01/01/1980 $250.00 RAU, ROBERT H Agent 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 DEVELOPERS SURETY Et INDEM CO 445594C 11/01/1997 Until Cancelled $4,000.00 06/15/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EREEB00414 8/10/2009 19.28.161 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 03/19/2012 / /; / /. /// /// VACANT SPACE SUITE 500 STARBUCKS'`COFFEE SUITE 300 EXISTING 200 AMP BARNES & NOBLE SUITE 200 NEW METERED SERVICE SEE E2. EXISTING ELECTRICAL ROOM DISTRIBUTION "A" EXISTING 200 AMP HOUSE PANEL EXISTING 400 AMPS NEW POWER AND TELEPHONE CONDUIT ROUTE EXISTING 600 AMPS PROJECT NUMBER: X DRAWING NUMBER: SHEET: 1 OF: 2 TO DISTRIBUTION PANEL Br TO DISTRIBUTION PANEL A +1 EXTG. DISTRIBUTION SWITCHBOARD #2 PSE METER #Z02780919 88.3 kW MAX. DEMAND PSE METER #Z02780939 92.0 kW MAX. DEMAND 400AF. 480Y/277V 30, 4W 600AF 480Y/277V 30, 4W PULL SECTION' 1200A HOUSE PANEL SUITE SUITE HP 300 100 1 TO NEW 200A PANEL 200A 200A' _r_ T 1 2 "C 4#3/0 CU & 1#6 CU GND 2 "C - 4#3/0 CU SEGALE PROPERTIES 5811 Segale Park Drive C. Tukwila; Washington! 98138. Phone: 206-575-2000 Fax: 206- 575 -1837 www.segaleproperile&com (4) 3 "C - 4#350 ` kCMIL CU -� ICASE I ENGINEERING 19515 North Creek Parkway, Suite 302 Bothell, WA 98011 Phone: 425 -402- 9400 •°Fax: 425- 402 -9402 TO EXISTING 300 kVA PSE TRANSFORMER! EXISTING RISER DIAGRAM. NOT TO SCALE Sheet Title: EXISTING RISER DIAGRAM SHADING INDICATES NEW WORK IN THIS CONTRACT. SEGALE - STRANDER RETAIL BLDG. Strander Blvd @ Andover Park East, Tukwila, WA Designed By: MSC Project No: 11151 Reference Dwg: Date: 01/18/12 Sheet Number: ESK 1.1 TTB '(E) NEW METER & DISCONNECT LOCATION SEGALE PROPERTIES 5811 Segale Park Drive C Tukwila, Washington 98138 Phone: 206-575-2000 Ex :206575-1837 www.segaleproperilescom. lull CASE I ENGINEERING 19515 North Creek Parkway, Suite 302 Bothell, WA 98011 Phone: 425 -402 -9400 • Fax: 425-402-9402 EXISTING ELECTRICAL ROOM PLAN SCALE: 1/8" = 1' -0 "` Sheet Title: EXISTING ELECTRICAL ROOM PLAN Project: SEGALE- STRANDER RETAIL BLDG. Strander Blvd @ Andover Park East, Tukwila, WA Designed By: Sheet Number: Project No: L' Tz 11151 I x«C' 71 Reference: Date: 01/18/12 1.3 1 SEGALE PROPERTIES 5811 Segale Park Drive C Tukwila, Washington 98138 Phone: 206-575-2000 Fax :206- 5755-1837 www.segaleproper8es.com - 200A /3P fr- l 1 200A 3P I r. I li 400A/ 6 00A/ 600A /` 400AF i 600AF L---- - - - - -J r 200A/200AF In-- PANEL HP SUITE 300 SUITE 100; ►- NEW 200A PANEL PROVIDE NEW FUSED DISCONNECT & METER. 200A /3P L, -r-----1-- TO DISTRIBUTION PANEL A TO DISTRIBUTION PANEL B ICASE v ENGINEERING 19515 North Creek Parkway, Suite 302 Bothell, WA 98011 Phone: 425 -402 -9400 • Fax: 425- 402 - 9402. PROVIDE NEW TAP ON 1200A, EXISTING 1200A BUS 4-80Y/277V, 30, 4W EXISTING ONELINE DIAGRAM`. NOT TO SCALE Sheet Title: EXISTING ONELINE DIAGRAM Project SEGALE- STRANDER RETAIL BLDG. Andover Park East, Tukwila, WA Strander Blvd @ Ad k T ukw il W Designed By: MSC Project No :_ 11151 Reference Dwg: Date: 01118/12 Sheet Number: ESQ 1.2 LOAD SUMMARY 1200A SWITCHBOARD - 480Y/277V, 3- PHASE, 4 -WIRE DESCRIPTION AREA W /SQ. FT. CONNECTED LOAD-kVA DEMAND FACTOR DEMAND kVA LOAD AMPS EXISTING LOAD MINIMUM PANEL RATING AVAILABLE FAULT CURRENT 0 PSE 300 kVA XFMR FEEDER TO 1200A SWBD (AIC SHOWN AT END OF FEEDER) FEEDER TO 200A DISCONNECT (AIC SHOWN AT END OF FEEDER) FEEDER TO 200A PANEL (AIC SHOWN AT END OF FEEDER) 25 N 350 kCMIL CU 4 5: M 3/0 CU 1 120 M 3/0 CU 1' 0.039 0.050 0.079 0.052 0.079 0.052 0.00000 0.01610 0.01610 0.00024 0.00031 0.00040 17,200 16,871 16,597' 11,057 DISTRIBUTION PANEL A 0.00024 0.01642 0.01642 0.00040 0.0002$ 0.00047 0.00064 0.01668 0.01669 0.00948 0.00624 0.01135 0.01012 0.02292 0.02505 NOTES TO CALCULATIONS: 1. CALCULATIONS ARE BASED ON OHMIC METHOD, 277 VOLTS UNE TO GROUND FAULT. 2. CONDUCTOR IMPEDANCE IS BASED ON NATIONAL ELECTRICAL CODE TABLE 9. 3. CONDUIT MATERIAL M =MAG, N= NON -MAG SSEGALE ( Ilk � �i CA ENGINEERING 19515 North Creek Parkway, Suite 302 Bothell, WA 98011 Phone: 425 -402 -9400 • Fax: 425-402-9402 MAX DEMAND PER PSE Designed lily: MsC Sheet Number: Project No 11151 ESK PROPERTIES 5811 Segale Park Drive c Tukwila. Washington 96138 Phone; 206- 575.2000 Fax: 206576 -1837' www.segaleproperties.com Reference Dwg: 88.3 kW 0 0.95 PF Date: 01/18112 92.9 1.25 116.2 140 DISTRIBUTION PANEL B MAX DEMAND PER PSE 92 kW 0 0.95 PF 96.8 1.25 121.1 146 SUITE 100 * ** 166.0 1.00 166.0 200 . SUITE 200 *** 166.0 1.00 166.0 200 HOUSE PANEL HP LIGHTING . 17.4 1.25 21.8 26 RECEPTACLES - GENERAL USE** 3.2 ,< * : >3.2 4 . TOTAL EXISTING LOAD 542.4 594.2 ...::.._._..716 _....,..: FUTURE LOAD - 200A PANEL LIGHTING 4,400 1.5 6.6 1.00 6.6 8 RECEPTACLES -- SPECIFIC USE 4,400 2.5 11.0` 1.00 11.0 13 RECEPTACLES - GENERAL USE ** 4,400 1.5 6.6 * 6.6.,. 8„ HVAC 4,400 15.0 66.0 1.00 66.0' '80 KITCHEN EQUIPMENT 40.0 0.65 26.0 31 TOTAL FUTURE LOAD 130.2 116.2 140 TOTAL 672.6 710.4 85& 0 480Y/277V 3Pkl, 4W *50% DEMAND ON GENERAL USE RECEPTACLES OVER 10 kVA * *DOES NOT INCLUDE RECEPTACLES FOR SPECIFIC EQUIPMENT ***FULL RATING OF FEEDER USED FOR LOAD PROPERTIES' 5811 Segale Park Drive C Washington 981381 Phone: 206;575 -2000 Fax 2065751837 www.segaleproperlies.com. IICASE F ENGINEERING 19515 North Creek Parkway, Sulte 302 Bothell, WA 98011 Phone: 425 -402 -9400 • Fax: 425 - 402 -9402 Sheet Title: LOAD SUMMARY Project: SEGALE - STRANDER RETAIL BLDG. Strander Blvd @ Andover Park East, Tukwila, WA Designed By :;: MSC Project No: 11151 Reference: Date: 01/18/12 ESK 1.4 REVIEWED w� 70 =NEC NFPA MAR 14 2012 Gay o� N BUILDING DIVISI REGtlyt�� CITY OFTUKWLA MAR 0 6 2012 PERMIT CENTER (f) D_ O a_ 0 ICI (f) A LIMITED LIABILITY COMPANY COMMERCIAL * INDUSTRIAL * AGRICULTURAL * NATURAL RESOURCES WWW. SEGALEPROPERTIES. COM z 0 U wz U V% Cr) 300 Andover Park West Da r" ib co PROJECT NUMBER: X DRAWING NUMBER: SHEET: OF: 2 SHORT CIRCUIT CALCULATIONS. DESCRIPTION CIRCUIT DEFINITION! CONDUIT # IN LENGTH MAT'L SIZE PARALLEL CONDUCTOR OHMS /MFT R X CIRCUIT IMPEDENCE OHMS R X Z AVAILABLE FAULT CURRENT MINIMUM PANEL RATING AVAILABLE FAULT CURRENT 0 PSE 300 kVA XFMR FEEDER TO 1200A SWBD (AIC SHOWN AT END OF FEEDER) FEEDER TO 200A DISCONNECT (AIC SHOWN AT END OF FEEDER) FEEDER TO 200A PANEL (AIC SHOWN AT END OF FEEDER) 25 N 350 kCMIL CU 4 5: M 3/0 CU 1 120 M 3/0 CU 1' 0.039 0.050 0.079 0.052 0.079 0.052 0.00000 0.01610 0.01610 0.00024 0.00031 0.00040 17,200 16,871 16,597' 11,057 22,000 22,000 14,000 0.00024 0.01642 0.01642 0.00040 0.0002$ 0.00047 0.00064 0.01668 0.01669 0.00948 0.00624 0.01135 0.01012 0.02292 0.02505 NOTES TO CALCULATIONS: 1. CALCULATIONS ARE BASED ON OHMIC METHOD, 277 VOLTS UNE TO GROUND FAULT. 2. CONDUCTOR IMPEDANCE IS BASED ON NATIONAL ELECTRICAL CODE TABLE 9. 3. CONDUIT MATERIAL M =MAG, N= NON -MAG SSEGALE ( Ilk � �i CA ENGINEERING 19515 North Creek Parkway, Suite 302 Bothell, WA 98011 Phone: 425 -402 -9400 • Fax: 425-402-9402 Sheet Title: SHORT CIRCUIT CALCULATIONS Project SEGALE- STRANDER RETAIL BLDG Strander Blvd @ Andover Park.. East, Tukwila, WA Designed lily: MsC Sheet Number: Project No 11151 ESK PROPERTIES 5811 Segale Park Drive c Tukwila. Washington 96138 Phone; 206- 575.2000 Fax: 206576 -1837' www.segaleproperties.com Reference Dwg: Date: 01/18112 REVIEWED w� 70 =NEC NFPA MAR 14 2012 Gay o� N BUILDING DIVISI REGtlyt�� CITY OFTUKWLA MAR 0 6 2012 PERMIT CENTER (f) D_ O a_ 0 ICI (f) A LIMITED LIABILITY COMPANY COMMERCIAL * INDUSTRIAL * AGRICULTURAL * NATURAL RESOURCES WWW. SEGALEPROPERTIES. COM z 0 U wz U V% Cr) 300 Andover Park West Da r" ib co PROJECT NUMBER: X DRAWING NUMBER: SHEET: OF: 2