Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL12-0217 - OFFICE DEPOT
OFFICE DEPOT 300 ANDOVER PK W EL12 -0217 City ofI'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049001 Address: 300 ANDOVER PK W TUKW Project Name: OFFICE DEPOT ELECTRICAL PERMIT Permit Number: EL12 -0217 Issue Date: 05/23/2012 Permit Expires On: 11/19/2012 Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA WA Contact Person: Name: ERIC KOCH Address: 16398 NE 85 ST, #101 , REDMOND WA Contractor: Name: WASHINGTON ELECTRIC LLC Address: 12501 SE 299 PL , AUBURN WA Contractor License No: WASHIEL887BT Phone: 425 636 -8006 Phone: 253 561 -5828 Expiration Date: 01/30/2014 DESCRIPTION OF WORK: REDUCTION IN SQUARE FOOTAGE OF RETAIL STORE. LIGHT FIXTURES TO BE ROTATED AND REUSED FOR NEW DESIGN /FIXTURE LAYOUT. NO INCREASE IN ELECTRICAL SERVICE. Value of Electrical: NRES: $60,000.00 RES: $0.00 Fees Collected: Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: $1,349.25 2008 Date: 3 /.? -.S// I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this per • oes not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or e perfo ce, ftt ork. I am authorized to sign and obtain this electrical permit. Signatur Print Name: P ,tc ) Date: 5/Z 3/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL12 -0217 Printed: 05 -23 -2012 • • PERMIT CONDITIONS Permit No. EL12 -0217 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -0217 Printed: 05 -23 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: Buz - o�i� Plz -a22 oci u1ll2 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: 90-O /J DC Vim— P k l.t es /- King Co Assessor's Tax No.: U 2,3o 4 5 D V/ D 9 Suite Number: '¢'IPA Floor: PROPERTY OWNER // Name: G KOC1/ Name: Address74354 IA �'5-' Address: F. D. 6 D,‹ 9-390 28' City: h d 10,40 Stagy tem City: —pi /14A 4ve4 State: km Zip: q 0 i CONTACT PERSON — person receiving all project communication // Name: G KOC1/ Address74354 IA �'5-' / 51- *-1 of City: h d 10,40 Stagy tem Zip �6,.O Phone: Fax: 6 36 good G zS ., , — Email: v,¢-7LeP ,06t. oil Zip: New Tenant: ❑ Yes .No ELECTRICAL CONTRACTOR INFORMATION Company Name: ri3fl Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ -.—T -- Cg 0, 000 , b v Scope of Work (please provide detailed information): (2Qci,,,� Cc 9 p ' f- O t ce ��. ' i� M ' ree2K 211,6/2-1- S F 79. of/pe-o,'. 2-3, 859 s f ).A9 EX-4-71-("24' .16"o(l ' Ser colt- Ne`^- (024` Ua `.i )( 4a thy ot7f. . / • l a , i;J € t Seitacc. Will service be altered? ❑ Yes ❑ No /Adding more than 50 amps? ❑ Yes J"' No Type of Use: MG't2(4n1 z,Y.E Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms- Applications On Line \201 I Applications\Electrical Permit Application Revised 8- 9- 11.docx Revised: August 2011 Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added /altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured /mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: •—\ Print Name: -rti Mailing Address: 1 LQ Th 84 ST lot H:\ Applications \Forms- Applications On Line\201 I Applications\Electrical Permit Application Revised 8 -9 -1 I.docx Revised: August 2011 bh Day Telephone: Date: 3 f -7 ( Z 1f25-Ct3(g - B066 Mown IA46" City c38QS2 State Zip Page 2 of 2 • • C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049001 Address: 300 ANDOVER PK W TUKW Suite No: Applicant: OFFICE DEPOT RECEIPT Permit Number: EL12 -0217 Status: APPROVED Applied Date: 03/07/2012 Issue Date: Receipt No.: R12 -01666 Initials: User ID: LAW 1632 Payment Amount: $1,079.40 Payment Date: 05/23/2012 02:08 PM Balance: $0.00 Payee: WASHINGTON ELECTRIC LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 030817 ACCOUNT ITEM LIST: Description 1,079.40 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 1,079.40 Total: $1,079.40 doc: Receiot -06 Printed: 05 -23 -2012 Cit of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: hup://www.ci.tukwila.wa. us SET RECEIPT RECEIPT NO: R12 -00956 Initials: JEM Payment Date: 03/07/2012 User ID: 1165 Total Payment: 1,530.14 Payee: ERIC KOCH SET ID: S000001713 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D12 -074 1,245.06 EL12 -0217 269.85 PG12 -041 15.23 TOTAL: 1,245.06 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 1,530.14 TOTAL: 1,530.14 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES PW BASE APPLICATION FEE PW PLAN REVIEW 000.345.832.00.0 000.345.830 000.322.100 000.345.830 TOTAL: 269.85 972.29 250.00 38.00 1,530.14 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6111'6i17 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 t (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: i 09 Address: "�, _ (A) Date Called: Special Instructions: Date Wanted:. r (a.rr: p Requester: Phone No: pproved per applicable codes. D.Corrections required prior to approval. COMMENTS: a° 4-11\1 t/ Inspector: (Date: `f1/Iz ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. April 13, 2012 Electrical Reviewer City of Tukwila, Dept. of Community Development 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 RE: Permit EL12 -0217 Office Depot 300 Andover Pk W, Ste 400 We have made some changes to our remodel in order to save costs on our construction. We have removed all plumbing changes from our scope of work and made some modifications to our electrical circuits and lighting layout. Please review the updated electrical plans for these changes. If there are any further questions and /or comments, please don't hesitate to call. Sincerely, Partners Architectural Design Group, Inc. Eric E. Koch Principal Encl: 4 sets electrical plans BEV tSO N0.1 ELI 1-011 wave) cavocn KWlll1 iAPR ;1.3 20121 PERMIT CENTER 16398 NE 85th Street, Suite 101 Redmond, WA 98052 425- 636 -8006 PERMITcQ' p COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0217 DATE: 04 -13 -12 PROJECT NAME: OFFICE DEPOT SITE ADDRESS: 300 ANDOVER PK W, SUITE 400 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 Before Permit Issued DEPARTMENTS_ _ (� (11F.J?ding' Division Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 04 -17 -12 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions 12( DUE DATE: 05 -15 -12 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 *EMIT COORD COP* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0217 PROJECT NAME: OFFICE DEPOT SITE ADDRESS: 300 ANDOVER PK W, STE 400 DATE: 03/06/12 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: c..c. ding ivision Public Works / n Fire Prevention Planning Division Structural n Permit Coordinator n o DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1p Incomplete DUE DATE: 03/08/12 Not Applicable o Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route IT Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/05/12 Approved n Approved with Conditions &/ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 02/29/12 PROJECT NAME: SITE ADDRESS: PERMIT NO: b 1_1) -- O DA 7 460 ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS STAFF INITIALS ISSUED DATE STAFF INITIALS I. 9-- 3— tom Summary of Revision: Received by: Summaryry of Revision: �dd(\, s n `. O� 4.br� l'ebJ b1-i eS S eik-te o w o r al V44. Received by:. P REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City it Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ¢ /I /5 /I - Plan ChecWPermit Number: L r2- o2 \-7 ❑ Response to Incomplete Letter # OzResponse to Correction Letter # J Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: (),F1 C Jp y'oi Project Address: 3 G 0 .Ac FY_ k) 5 4 0 0 Contact Person: t C_ \.6 C44 Phone Number: S [e 3 Co O 60 (.p Summary of Revision: %.l H. PsV.E l f '- c-f l.16. es -TT) our S cor - k L n tvG-E1 'Q rid 1 N4 Ou\- c_A-s 1 -1 K ce S Dery . Keys 1-Yt S ArLS Min( ivCA tAxv -t 1 43M - Scowo C &kD'r . k e t7 OUX_ ruisays '�Ft -��' �►o t'- 1d.i Uv t-t r i nzt . M t L[i cr - L— C.4- lvet cS 3wr.l . Afut_ e--5 PrKse, -t_ - 4— i�.Q121 iegl iMR CENTER Sheet Number(s): i2- EYKa`f 1°101, 2-0 1 -3 6 1 RoV if-A( Prowl, 100 f 16Z, I03, SOZ "Cloud" or highlight all areas of revision including date of revision c'''Orr v.-et t o$ , 162, 163, 501,36? 4-61 Received at the City of Tukwila Permit Center by: tEr Entered in Permits Plus on Li ( o H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Revision Submittal.doc Revised: May 2011 Contractors or Tradespeople Peer Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company WASHINGTON ELECTRIC LLC 2535615828 12501 Se 299Th Pl Auburn WA 98092 King Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 603017983 Active WASHIEL887BT Electrical Contractor 1/30/2012 1/30/2014 General Unused Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WASHIE'908CA WASHINGTON ELECTRIC Electrical Contractor General Unused 2/1/2010 2/1/2012 Re- Licensed Electrical Administrator INFORMATION License JOHNSED919RZ Name JOHNSON, ERIC D. Status Active Business Owner Information Name Role Effective Date Expiration Date JOHNSON, ERIC D Partner /Member 01/30/2012 JOHNSON, MICHELLE R Partner /Member 01/30/2012 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 Lexon Ins Co 9806063 05/16/2011 Until Cancelled $4,000.00 01/30/2012 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type https: // fortress .wa.gov /lni/bbip /Print.aspx 05/23/2012 LIGHTING OUTSIDE THE LEASE SPACE IS EXISTING TO REMAIN AND THE LANDLORD'S RESPONSIBILITY. LIGHTING AND CONTROLS WITHIN AREA ARE EXISTING TO REMAIN AND SHOWN FOR REFERENCE ONLY UNLESS NOTED OTHERWISE. I3I NOTE NOT USED. 5 EXISTING LIGHTING OVERRIDE CONTROLS. SEE LIGHTING KEY NOTE 7 FOR ADDITIONAL INFORMATION. PROVIDE EMERGENCY BALLAST TO OPERATE (2) T8 LAMPS AT A MINIMUM OF '1453 LUMENS FOR 90 MINUTES. 1. TYPE 'X', 'XEM', AND 'EM' FIXTURES SHALL BE MOUNTED ON WALLS, OR SUSPENDED FROM STRUCTURE. PROVIDE STEM MOUNTING FOR ALL EXIT SIGNS LOCATED IN SALES AND RECEIVING AREAS UNLESS OTHERWISE NOTED. PROVIDE WHITE PENDANT WITH SWIVEL FITTING. EXIT LIGHTS SHALL HANG 12" LOWER THAN FLUORESCENT FIXTURES. VERIFY WORKING CONDITION OF EXISTING EXIT AND EMERGENCY LIGHT FIXTURES AND RELOCATE TO NEW LOCATIONS AS INDICATED IF IN PROPER WORKING CONDITION. OFFICE DEPOT TO FURNISH NEW FIXTURES AS REQUIRED TO MEET THE DESIGN INTENT. NEW AND RELOCATED LIGHTING TO BE INSTALLED BY CONTRACTOR. ALL EXIT & EMERGENCY LIGHTS SHALL BE WITH A LOCK -ON CIRCUIT BREAKER. ONCE LIGHTS SHALL NOT BE TURNED OFF. FOR CURRENTLY SWITCHED, PROVIDE CONSTANT BALLAST. CONNECTED TO AN UNSWITCHED CIRCUIT ENERGIZED DURING CONSTRUCTION THE EXISTING FLUORESCENT FIXTURES HOT CONDUCTOR TO NEW EMERGENCY 6. REFER TO DETAIL 1 SHEET E301 FOR LIGHTING FIXTURE SCHEDULE. 7. ALL EXISTING SALES FLOOR LIGHT FIXTURES TO BE RELOCATED AS SHOWN. MATCH MOUNTING HEIGHT OF EXISTING LIGHT FIXTURES. TURN OVER EXISTING FIXTURES NOT BEING REUSED TO OWNER. OFFICE DEPOT TO FURNISH NEW FIXTURES AS REQUIRED TO MEET THE DESIGN INTENT. FIELD VERIFY QUANTITIES OF EXISTING FIXTURES. NEW AND RELOCATED LIGHTING TO BE INSTALLED BY CONTRACTOR. PROVIDE EMERGENCY BALLAST TO OPERATE (1) T5 LAMP PER 8' SECTION AT A MINIMUM OF 940 LUMENS FOR 90 MINUTES. EXISTING LIGHTING CONTACTORS AND ENERGY MANAGEMENT SYSTEM. RE -WORK AS REQUIRED TO MAINTAIN SALES AREA CHECKERBOARD LIGHTING PATTERN. REFER TO GENERAL NOTE 3. COORDINATE REPROGRAMMING WITH OFFICE DE POT CONSTRUCTION MANANGER. NOTE NOT USED. PARALLEL ROWS OF LIGHTS IN THE RETAIL AREA SHALL BE CIRCUITED TO ACHIEVE A CHECKERBOARD PATTERN OF "PARTIAL 1" AND "PARTIAL 2" CONTROLLED CIRCUITS, TO ALLOW FOR AN EVEN 50% LIGHTING PATTERN THROUGHOUT. REFER TO DETAILS 2 AND 3 ON SHEET E301 FOR GENERAL ELECTRICAL NOTES, LEGEND WITH ABBREVIATIONS, AND FIXTURE SCHEDULE. REFER TO DETAIL 2 SHEET E401 FOR CONTACTOR SCHEDULE INCLUDING LIST OF CONTROLLED CIRCUITS. 8. ABANDON EXISTING LIGHT FIXTURES IN EXCESS SPACE. CUT AND TERMINATE CONDUITS AND WIRES IN EXCESS SPACE WITHIN 1' -O" OF DEMISING WALL. REMOVE ALL CONDUIT AND WIRES IN NEW OFFICE DEPOT SPACE THAT ARE NOT RE -USED. LABEL DEMOLISHED CIRCUITS IN PANELBOARDS AS "SPARE" AND TURN EXISTING BREAKER TO OFF POSITION. COORDINATE EXACT REQUIREMENTS AND EXISTING CONDITIONS WITH CONSTRUCTION MANAGER PRIOR TO BID. 9. CONNECT CIRCUITS TO EXISTING BRANCH CIRCUITRY WHEN POSSIBLE. MINIMUM WIRE SIZE AND PANELBOARD CIRCUIT ARE NOTED. VERIFY SIZE, RATING AND CONDITION OF EXISTING BRANCH CIRCUIT CONDUIT AND WIRE PRIOR TO USE TO ENSURE THEY MEET REQUIRED SIZE, AND ALL U.L. RATINGS AND REPLACE AS REQUIRED. 10. ENSURE ALL LIGHTING CONTROLS MEET COMMISSIONING REQUIREMENTS PER WASHINGTON STATE ENERGY CODE SECTION 1513.8. (1\ 12. ALL LIGHTING CIRCUITS ARE FED FROM EXISTING PANELBOARD "LA ". FIXTURES DESIGNATED UNSWITCHED (WITH "U " E.G. 1 1 U) SHALL BE CONNECTED TO THE CIRCUIT AHEAD OF (ON THE LINE SIDE OF) LIGHTING CONTACTOR. EMERGENCY BALLASTS SHALL BE FED FROM THE SAME CIRCUIT AS THE AC BALLAST. EMERGENCY FIXTURES NOT DESIGNATED AS NL (NIGHT LIGHT) FIXTURES: SHALL BE CONTROLLED BY THE EMS SYSTEM IN NORMAL OPERATION AND SHALL OPERATE IN EMERGENCY MODE DURING POWER OUTAGES. 13. REFER TO DETAIL 1 SHEET E102 FOR POINT -BY -POINT EMERGENCY EGRESS CALCULATIONS. FILE COPY Permit No. Pi— *4dw approval Is stmt to errors and omission& of conetruciion documents does not authorize `'- " of `.rn opted code or ordinance. Receipt c` Leiprovlc Field 1 and Is wedged: .tom 1HENDERSON ENGINEERS 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 Fax 913 7425001 www.hei-eng.com 1250000367 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/12 Office Depot Approval Stamp 11. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR ADDITIONAL INFORMATION AND DEMOLITION REQUIREMENTS. B Date: LIGHTING KEY NOTES SCALE: NONE elLIGHTING GENERAL NOTES SCALE: NONE 2) dty Of7Wkrrlls BUILDING DIVISION REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC APR 19 2012 Cit�{o Tukwila Architecture Partners Architectural Design. Group, Inc. 16398 NE 85TH ST. SUITE 101 Redmond, WA 98052 Telephone 425 636 -8006 www.padgi.com 1/2" G.R.M.C. SECURELY ATTACHED TO JOIST 1/2" G.R.M.C. THREADED ON BOTH ENDS. PAINT WHITE. o 1 �� L`t, . t-U D 1 LL p 1 LL 4.1.,.L.-1-L, D 1 LL PENDANT MOUNTING BRACKET EXIT ELECTRICAL CONTRACTOR SHALL MOUNT EXIT LIGHTS IN SALES AREA 1' -0 TO TOP OF SIGN BELOW GENERAL LUMINAIRE MOUNTING HEIGHTS. SURFACE MOUNT TO WALL OR SUSPENDED CEILING IN AREAS WITH SUSPENDED CEILING. MEP Henderson Engineers, Inc. 8325 Lenexa Drive Lenexa, KS 66214 Telephone 913.742.5000 Fax 913.742.5001 www.hei - eng.com Revisions / Issues PNLBD LA LIGHTING AND CIRCUITRY IN THIS AREA AND MEZZANINE IS EXISTING TO REMAIN. VERIFY PROPER WORKING CONDITION OF NORMAL AND EGRESS LIGHTING AND REPLACE AS REQUIRED. �LIVI .. _ �i, gj ....r.... _ 28U. 231 28 0 ,'C I ©' VOA?'" Aoopd ,c, 28 Ilk 28 II MIAmn ii%i f,'Wr 28 'C''2411 ' :_ �i , , i l J! ltf !;L'i �� ' 28 28 28 �2 28 m 2: 2 ippy z„ 0 'C C' ° C' 'B,_ u C o 8. /%f% 28 28 0 /� 'C' 2a 2 2 `A/ /iYl� 28 -- 28_ C, Di LIGHTING AND CIRCUITRY IN THIS AREA IS EXISTING TO REMAIN. VERIFY PROPER WORKING CONDITION OF NORMAL AND EGRESS LIGHTING AND REPLACE AS REQUIRED. EMERGENCY /EXIT LIGHT MOUNTING DETAIL NOTES: 1. MOUNTING HARDWARE SHALL BE COMPATIBLE WITH CABLE SYSTEM. VERIFY COMPONENTS REQUIRED. 2. WHERE REQUIRED BY SEISMIC ZONE, PROVIDE SPLAY CABLE FOR SEISMIC BRACING AT CORNERS OF FIXTURES. 3. USE 3/8" THREADED ROD INSTEAD OF AIRCRAFT CABLE WHERE REQUIRED BY LOCAL CODE. CONTRACTOR SHALL VERIFY WITH LOCAL INSPECTOR BEFORE INSTALLATION. Office DEPOT &brig Cate ofikameir COIL EXCESS CABLE AT AT BAR JOIST. BUY GREEN SELL GREEN BE GREEN RELOCATED LIGHT FIXTURE, TYPICAL OF SALES AREA. P WIRING WHIP PROVIDED WITH FIXTURE 2010 PROTOTYPE OD STORE #XXXX 6600 North Military Trail N278 Boca Raton, FL 33496 TEL: 561/438-6299 FAX: 561/438-7237 CADDY SPEED LINK UL LISTED CABLE SYSTEM. MINIMUM 100# RATING. SECURE WIRING TO BOTTOM CHORD OF BAR JOIST. EXCESS SPACE TO BE CONVERTED TO NEW TENANT SPACE BY LANDLORD. NEW WORK IN EXCESS SPACE COMPLETED UNDER SEPARATE CONTRACT AND PERMIT. P1000 UNISTRUT CHANNEL SECURELY FASTENED TO TOP OF JOISTS. REVISION Project Title Office Dept #0984 300 Andover Park W #400 Tukwila, WA 98188 CADDY SPEED LINK LOCKING DEVICE. Gross Tenant Area: 22,199 sq. ft. CADDY SPEED LINK HOOK WITH SAFETY CLIP. rt / '1:737777177 /„.k`--'147.-ftzr -,:2 /// ".-;4;?''-i?(,,;650%;„r=',,',„%;..%;,,,,,):,,',1;./::01,fr' t'' ///z// ///' /,•/°:/: „0";;Ij se" rd' t,;741,41?:e2f,,, ):4:-,.,' : W, ,,,,11 /,,..doo„ / /� /i'�ii� / /d�irii� ii�if dpi /,fi�ri /�Jii:�i�ii� i, forAl RECEIVED APR 13 2012 PERMIT CENTER FLUORESCENT LIGHTING FIXTURE Job Number CONTRACTOR SHALL BEND TABS UP FOR SUPPORTING LIGHTS. Scale AS NOTED ON DRAWING //0/ /7 7/ /4/ //d r1iLINEAR FLUORESCENT LUMINAIRE MTG. DETAIL SCALE: NONE PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THESE DRAWINGS.' // LIGHTING PLAN SCALE: 3/32" = 1' -0" NOTE: EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS. AND MAY NOT REFLECT EXACT "AS— BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. E101 Luminaire Schedule Label CalcType Units Symbol Qty Label Avg /Min Arrangement Lumens LLF Description 3.38 Total Lumens 0 24 AE Illuminance SINGLE 470 0.750 MSSHB 2 54T5H0 SBL MMD 940 Sales 0 8 BE and FE SINGLE 726.5 0.750 WS -232A 1453 m 16 EM AND XEM SINGLE 132 1.000 029 -84 132 REFER TO DETAILS 1, 2, AND 3 ON SHEET E101 FOR ADDITIONAL INFORMATION. REFER TO DETAIL 1 SHEET E301 FOR LIGHTING FIXTURE SCHEDULE. REFER TO ARCHITECTURAL LIFE SAFETY PLAN FOR ADDITIONAL INFORMATION. VALUES INDICATED ALONG THE PATH OF EGRESS ARE AT THE FLOOR LEVEL. [i] EMERGENCY EGRESS LIGHTING GENERAL NOTES SCALE: NONE Calculation Summary Label CalcType Units Avg Max Min Avg /Min Max /Min Vestibule Illuminance Fc 3.38 4.35 2.20 1.54 1.98 Receiving Illuminance Fc 1.18 2.63 0.16 7.38 16.44 Sales Illuminance Fc 1.23 3.43 0.23 5.35 14.91 (4) DIE. DIG 0.65 0.65 . X0.81 1.16 1.69 2.22 2.47 2.26 1.74 1.24 X0.88 ;0.71 0.74 0.98 1.38 1.91 2.38 2.47 2.13 1.62 1.1�. ! .ii�l MI (!�} 4F At, Y/r//://1//// rff#09///// EXCESS SPACE TO BE CONVERTED TO NEW TENANT SPACE BY LANDLORD. NEW WORK IN EXCESS SPACE COMPLETED UNDER SEPARATE CONTRACT AND PERMIT. EMERGENCY EGRESS LIGHTING CALCULATIONS PLAN SCALE: 3/32" = 1' -0" r Ay/ ,r/777,„ /7/ //// NOTE: REV LA�N�NCE w TH PA 70 NEC - APR 19 2012 - "-city of Tukwila. BUILDING DIVISION RECEIVED APR 13 2012 PERMIT CENTER EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS- BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. 1HENDERSON ENGINEERSN 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hel-eng.com 1250000367 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/12 Office Depot Approval Stamp Architecture Partners Architectural Design Group, Inc. 16398 NE 85TH ST. SUITE 101 Redmond, WA 98052 Telephone 425 636 -8006 www.padgi.com MEP Henderson Engineers, Inc. 8325 Lenexa Drive Lenexa, KS 66214 Telephone 913.742.5000 Fax 913.742.5001 www.hei - eng.com Revisions / Issues REV DATE DESCRIPTION 3.6.12 BLDG. PERMIT SUBMITTAL 4.2.12 SCOPE REDUCTION Office DEPOT TwENrf Cate 9fr BUY GREEN SELL GREEN BE GREEN 2010 PROTOTYPE OD STORE #XXXX 6600 North Military Trail N278 Boca Raton, FL 33496 TEL: 561/438-6299 FAX: 561/438-7237 Seal Project Title Office Dept #0984 300 Andover Park W #400 Tukwila, WA 98188 Gross Tenant Area: 22,199 sq. ft. Job Number Drawing EMERGENCY EGRESS LIGHTING PLAN Scale AS NOTED ON DRAWING Drawing Date 3.6.12 PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THESE DRAWINGS. Drawing No. E102 CRAIG R. LANHAM REFER TO DETAILS 2 AND 3 ON SHEET E301 FOR GENERAL ELECTRICAL NOTES, AND LEGEND WITH ABBREVIATIONS. 2. CONTRACTOR SHALL FURNISH AND INSTALL ALL UNDER CARPET CABLE COMPONENTS AS NOTED AND SHALL ALSO INCLUDE NECESSARY QUANTITIES OF 'AMP' FLOOR ADHESIVE, FLOOR PREPARATION ROLL, TOP SHIELD, TOP SHIELD BONDING CLIPS, AND • HOLD DOWN TAPE FOR A COMPLETE INSTALLATION OF UNDER CARPET WIRING SYSTEM. FLOOR PREP AND TOP SHIELD IS ONLY REQUIRED ON POWER WIRING. FOLLOW MANUFACTURER'S REQUIREMENTS AND SPECIFICATIONS FOR INSTALLATION OF POWER • AND VOICE /DATA WIRING. VERIFY COLORS AND EXACT LOCATIONS OF DEVICES WITH OWNER PRIOR TO CONSTRUCTION. COORDINATE INSTALLATION OF UNDER CARPET WIRING WITH CARPET AND FIXTURE INSTALLER. PART NUMBERS AND QUANTITIES TO BE VERIFIED.' BY MANUFACTURER PRIOR TO CONSTRUCTION. INSTALLATION SHALL COMPLY WITH NEC ARTICLE 324. ABANDON ALL ELECTRICAL DEVICES IN EXCESS SPACE. CUT AND TERMINATE ALL CONDUITS AND WIRES TO WITHIN 1' -0" OF NEW DEMISING WALL. REMOVE ALL CONDUIT AND WIRES IN NEW OFFICE DEPOT SPACE THAT ARE NOT RE -USED. LABEL DEMOLISHED CIRCUITS IN PANELBOARDS AS "SPARE" AND TURN EXISTING BREAKER TO OFF POSITION. COORDINATE EXACT REQUIREMENTS, REUSE OF EXISTING EQUIPMENT, AND EXISTING CONDITIONS WITH OFFICE DEPOT CONSTRUCTION MANAGER PRIOR TO BID. POWER GENERAL NOTES SCALE: NONE, CONNECT CIRCUITS TO EXISTING BRANCH CIRCUITRY WHEN POSSIBLE. MINIMUM WIRE SIZE AND PANELBOARD CIRCUIT ARE NOTED. VERIFY SIZE, RATING AND CONDITION OF EXISTING BRANCH CIRCUIT CONDUIT AND WIRE PRIOR TO USE TO ENSURE THEY MEET REQUIRED SIZE, AND ALL U.L. RATINGS AND REPLACE AS REQUIRED. 5. DISCONNECT ALL EXISTING SECURITY, FIRE ALARM, HVAC CONTROLS, DUCT SMOKE DETECTORS AND OTHER LOW VOLTAGE DEVICES WITHIN EXCESS SPACE FROM OFFICE DEPOT'S FIRE ALARM CONTROL PANEL, ENERGY MANAGEMENT SYSTEM, ETC. COORDINATE WITH OFFICE DEPOT CONSTRUCTION MANAGER AND LOW VOLTAGE CONTRACTOR. 6. REFER TO OWNER PROVIDE FIXTURE PLAN FOR VOICE /DATA REQUIREMENTS. PROVIDE OUTLET BOXES AND CONDUIT AS REQUIRED. 7. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION. REMOVE ALL ELECTRICAL DEVICES AND CIRCUITRY AFFECTED BY DEMOLITION. 8. PROVIDE LISTED HANDLE -TIE BETWEEN CIRCUIT BREAKERS SHARING COMMON NEUTRAL FOR COMMON TRIP. RELOC CABLE WITH PIG TAILS, FURNISHED BY OWNER, INSTALLED BY ELECTRICAL CONTRACTOR. COORDINATE WITH CONSTRUCTION MANANGER (3 CABLES) 1 PROVIDE AN UPDATED, COMPLETE, TYPEWRITTEN PANELBOARD IDENTIFICATION SCHEDULE AND PLACE ON INTERIOR SIDE OF DOOR FOR ALL EXISTING AND NEW PANELBOARDS. TRACE EXISTING LOADS AS REQUIRED TO PROVIDE A DESCRIPTION FOR THE SPECIFIC PURPOSE OR USE OF THE CIRCUIT PER NEC 408.4. NOTE NOT USED. 8 7/ VOICE /DATA JACKS TO BE MOUNTED IN LOW PROFILE FLOOR FITTING. REFER TO OWNER PROVIDED FIXTURE PLAN FOR ADDITIONAL INFORMATION. 3 RELOC HOME RUN CABLE ROUTED FROM POWERRAIL UP THROUGH POWER POLE. FURNISHED AND ' `- INSTALLED BY OWNER POWERRAIL FURNISHED AND INSTALLED BY OWNER, TYPICAL REFER TO OWNER PROVIDED FIXTURE PLAN FOR EXACT LOCATION OF UNDER CARPET CABLE DEVICES. UNDER CARPET CABLE PLAN SCALE: 1/4" = 1' -0" 4 5 6 7 8 9 CONTACTORS PNLBD LA PNLBD MDP PNLBD C TELEPHONE 11 12 PROVIDE "AMP" #1375032 -1 SURFACE MOUNTED WALL TRANSITION BOX AND COVERPLATE KIT AT 10" AFF AND 554862 -1 TRANSITION BLOCK FOR UNDER CARPET POWER WIRING CONNECTION. VERIFY EXACT LOCATION WITH ARCHITECT PRIOR TO INSTALLATION. ENERGY MANAGEMENT 13 XFMR Ti PROVIDE "AMP" #553445 #10 AWG (3) CONDUCTOR FCC POWER CABLE AS NEEDED. PROVIDE "AMP" #1375032 -1 SURFACE MOUNTED WALL TRANSITION BOX AND COVERPLATE KIT AT 10" AFF AND #1479384 -1 BLOCK FOR TRANSITION FROM ROUND VOICE /DATA CABLING TO AMP UNDER CARPET CABLING SYSTEM. PROVIDE 3/4" CONDUIT WITH PULL STRING STUBBED TO CEILING STRUCTURE FROM TRANSITION BOX FOR VOICE /DATA CABLING, TERMINATE WITH BUSHINGS. PROVIDE (3) "AMP" #558054 -1 RJ45 JACKS WITH (3) #569996 -1 BRACKETS FOR FIXTURE VOICE AND /OR DATA REQUIREMENTS. JACKS MOUNTED IN (1) #555287 LOW PROFILE TWO PORT FITTING. PROVIDE "AMP" #1499119 -1 CATEGORY 5e CMUC CABLES. PROVIDE "AMP" #554192 DUAL DUPLEX DIRECT CONNECTING RECEPTACLE. PROVIDE JUNCTION BOX AT BOTTOM OF DECK FOR INRACK LIGHTING. INSTALL MODULAR WIRING ADAPTER FURNISHED BY INRACK LIGHTING VENDOR. CIRCUIT AS SHOWN. RELOCATED PLUG AND PLAY JUNCTION BOXES, INSTALLED BY ELECTRICAL CONTRACTOR. MOUNT WITHIN 6" OF JOIST TO UNISTRUT SPANNING TOP OF BAR JOISTS, SECURELY FASTENED TO JOISTS. PLUGS SHALL FACE REAR OF STORE. CONTRACTOR SHALL PROVIDE LABEL AT EACH J -BOX WITH CIRCUIT NUMBERS INDICATED IN 1/4" HIGH PRINTED LETTERS. INSTALL LABELS AFTER ROOF IS PAINTED. WIRING FROM J -BOX TO STORE FIXTURES IS BY OTHERS. CONDUIT AND WIRING TO PANELS IS BY ELECTRICAL CONTRACTOR. RELOCATED IN -RACK LIGHTING FIXTURES. FIXTURES ARE PROVIDED WITH FACTORY INSTALLED MODULAR WIRING. TYPICAL. COORDINATE WITH OFFICE DEPOT CONSTRUCTION MANAGER. FIELD VERIFY VOLTAGE AND NOTIFY ARCHITECT /ENGINEER IF NOT 120V. EXISTING BALER DISCONNECT AND CIRCUITRY TO REMAIN. Architecture 1HENDERSON ENGINEERS 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hel- eng.com 1250000367 WA. CORPORATE NUMBER:1754 EXPIRES 06/30/12 Office Depot Approval Stamp Partners Architectural Design Group, Inc. 16398 NE 85TH ST. SUITE 101 Redmond, WA 98052 Telephone 425 636 -8006 www.padgi.com MEP Henderson Engineers, Inc. 8325 Lenexa Drive Lenexa, KS 66214 Telephone 913.742.5000 Fax 913.742.5001 www.hei- eng.com INTERCEPT AND EXTEND EXISTING CIRCUIT FOR AUTOMATIC SLIDING DOOR TO NEW PANELBOARD AS INDICATED AND MAKE FINAL CONNECTIONS PER MANUFACTURER'S SPECIFICATIONS. Revisions / Issues EXISTING LANDLORD ELECTRICAL ROOM LOCATED AT BASE OF EXISTING RAMP. OE3U 880 14 An A A AA PB -38,40 15 INTERCEPT AND EXTEND EXISTING STOREFRONT SIGNAGE CIRCUITS TO NEW PANELBOARD AS INDICATED. MAINTAIN EXISTING CONTROLS. 3.6.12 4.2.12 DESCRIPTION BLDG. PERMIT SUBMITTAL SCOPE REDUCTION ALL ELECTRICAL DEVICES AND CIRCUITRY IN THIS AREA ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. 808 8UU anneeen PB- 35,37,3 // 4/f","%Y/.//f7 /////:7"///;//,/,%7- /////// 7/////, EXISTING PLUG AND PLAY JUNCTION BOXES. PLUGS SHALL FACE REAR OF STORE. CONTRACTOR SHALL PROVIDE LABEL AT EACH J -BOX WITH CIRCUIT NUMBERS INDICATED IN 1/4" HIGH PRINTED LETTERS. WIRING FROM J -BOX TO STORE FIXTURES IS BY OTHERS. ELECTRICAL CONTRACTOR TO FIELD VERIFY QUANTITIES OF EXISTING CIRCUITS AT EACH PLUG AND PLAY JUNCTION BOX AND PROVIDE NEW CONDUCTORS TO MATCH QUANTITIES SHOWN. PB- 49,51,53 B 32,34,36 4 PB- 55,57,59 PB- 67,69,71 PB -61 63,65 RELOCATE EXISTING PLUG & PLAY BOX, REFER TO KEYNOTE #10. PB- 13,15,17 11111 - ,PD- 32,34,36 PD- 20,22,24 EXCESS SPACE TO BE CONVERTED TO NEW TENANT SPACE BY LANDLORD. NEW WORK IN EXCESS SPACE COMPLETED UNDER SEPARATE CONTRACT AND PERMIT. PD- 38,49,42 PD -1,3,5 PD -7,9(I PD-37,39,41 • F-15,1 (IG] PD -26,2 ,30 PD -11 rPD -13 0 PD- 8,10,12 9,21(t PD -2,4,6 RELOCATED XFMR T2 (SUSPENDED) RE: 3 -E401— Wes. i �//y �%d / f A PNP BOX LOAD SERVED A,B,C CHECKOUTS, CHECKOUTS IG, SODA COOLER D SELF SERVE COPIERS E,F SHIPPING COUNTER, SHIPPING COUNTER IG G DPC BACK COUNTER H SELF SERVE COPIERS 1 POWERPOLEQ #1 J POWER POLE H+ K DPC COUNTER, DPC COUNTER IG L POWER POLE 0 #2 M TECH DEPOT N LAPTOPS, TABLETS 0 WIRELESS, DESKTOPS, NETWORKING P INK, TONER ENDCAPS, MONITORS Q TONER, FAX, INKJET R INK, LASER PRINTERS S LASER PRINTERS, MP3 ACCESSORIES ^� T TELEPHONES, CALCULATORS, MP3, GPS �( U SPARE AP ✓ FURNITURE PAD PERM Office DEPOT y Care af Seal BUY GREEN SELL GREEN BE GREEN 2010 PROTOTYPE OD STORE #XXXX 6600 North Military Trail N278 Boca Raton, FL 33496 TEL: 561 /438 -6299 FAX: 561/438-7237 ELECTRICAL CONTRACTOR TO FIELD VERIFY QUANTITIES OF EXISTING CIRCUITS AT EACH EXISTING PLUG AND PLAY JUNCTION BOX AND PROVIDE NEW CONDUCTORS TO MATCH QUANTITIES SHOWN. LEGEND PROVIDED FOR REFERENCE ONLY TO COVEY CIRCUITING INTENT. COORDINATE WITH OFFICE DEPOT CONSTRUCTION MANAGER. PROVIDE UPDATED CIRCUIT DIRECTORIES, INCLUDING LOAD SERVED, FOR ENTIRE PLUG & PLAY SYSTEM AT EACH PANELBOARD. REFER TO KEY NOTES AND OFFICE DEPOT PROVIDED FIXTURE PLAN FOR ADDITIONAL INFORMATION. PD -23 PD -25 PD -27 PD -29 PD -40 RELOCATED PNLBD PD RELOCATE EXISTING PLUG & PLAY BOX, REFER TO KEYNOTE #10. Project Title Office Dept #0984 300 Andover Park W #400 Tukwila, WA 98188 Gross Tenant Area: 22,199 sq. ft. Job Number Drawing POWER PLAN Scale AS NOTED ON DRAWING Drawing Date 3.6.12 IIPA PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THESE DRAWINGS. Drawing No. POWER PLAN SCALE: 1/8" = l'-O" EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS- BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. E103 LIGHTING FIXTURE SCHEDULE TAG BASE SPECIFICATION LAMP VOLTAGE COLOR MOUNTING KEYNOTES MANUFACTURER MODEL QUANTITY SIZE /TYPE VA WATTS TYPE HEIGHT A EXISTING /RELOCATED SALES AREA LOW PROFILE 8 TANDEM FLUORESCENT WITH REFLECTOR AND PROGRAM START ELECTRONIC BALLAST. 4 F54T5 /HO /SP35 /ECO 240 240 277 WHITE CEILING SUSPENDED MATCH EXISTING 3, 4, 5 AE ,EXISTING/RELOCATED SALES AREA LOW PROFILE 8' TANDEM FLUORESCENT WITH REFLECTOR AND PROGRAM START ELECTRONIC BALLAST. FIELD INSTALLED EMERGENCY BALLAST. 4 F54T5 /HO /SP35 /ECO 240 240 277 WHITE CEILING SUSPENDED MATCH EXISTING 1, 3, 4, 5 AE /NL EXISTING/RELOCATED SALES AREA LOW PROFILE 8' TANDEM FLUORESCENT WITH REFLECTOR AND PROGRAM START ELECTRONIC BALLAST. FIELD INSTALLED EMERGENCY BALLAST. NIGHT LIGHT. 4 F54T5 /HO /SP35 /ECO 240 240 277 WHITE CEILING SUSPENDED MATCH EXISTING 1, 3, 4, 5 B EXISTING RECEIVING AREA WRAP AROUND 8' TANDEM FLUORESCENT WITH PRISMATIC LENS AND ELECTRONIC BALLAST. 4 F32T8 /XL /SP35 /ECO 114 112 277 WHITE CEILING SUSPENDED AL 3, 4 kcmil 1000 CIRCULAR MILS RECEIVING AREA WRAP AROUND 8' TANDEM FLUORESCENT WITH PRISMATIC LENS AND 4 F32T8 ANALOG OUTPUT 112 KIRK KEY WHITE CEILING SUSPENDED AP , E31 EXISTING /RELOCATED ELECTRONIC BALLAST. SQUARE FEET, SUPPLY FAN /XL /SP35 /ECO 114 kVA 277 SPDT SINGLE —POLE, DOUBLE —THROW BKR 3, 4 1 BE EXISTING RECEIVING AREA WRAP AROUND 8' TANDEM FLUORESCENT WITH PRISMATIC LENS AND ELECTRONIC BALLAST. FIELD INSTALLED EMERGENCY BALLAST. F32T8 /XL /SP35 /ECO 114 112 277 WHITE CEILING SUSPENDED CD 1, 3, 4 B1E EXISTING /RELOCATED RECEIVING AREA WRAP AROUND 8' TANDEM FLUORESCENT WITH PRISMATIC LENS AND F32T8 /XL /SP35 /ECO 114 112 277 WHITE CEILING SUSPENDED CAN 1, 3, 4 ►. MAXIMUM ELECTRONIC BALLAST. FIELD INSTALLED EMERGENCY BALLAST. SWITCHBOARD CCTV CLOSED CIRCUIT TELEVISION MCA MINIMUM CIRCUIT AMPACITY TL TWISTLOCK CKT I MCB EXISTING OFFICE /RESTROOM /LOUNGE AREA 2x4 FLUORESCENT TROFFER WITH PRISMATIC LENS AND ELECTRONIC BALLAST. 3 F32T8 /XL /SP35 /ECO 86 85 277 WHITE CEILING RECESSED CVD CUMULATIVE VOLTAGE DROP F EXISTING VESTIBULE 4' FLUORESCENT WRAP AROUND WITH PRISMATIC LENS AND ELECTRONIC BALLAST. 4 F32T8 /XL /SP35 /ECO 114 112 277 WHITE SURFACE MOUNTED DPDT DOUBLE —POLE, DOUBLE —THROW FE EXISTING VESTIBULE 4' FLUORESCENT WRAP AROUND WITH PRISMATIC LENS AND ELECTRONIC BALLAST. FIELD INSTALLED EMERGENCY BALLAST. 4 F32T8 /XL /SP35 /ECO 114 112 277 WHITE SURFACE MOUNTED EM 1 MIN MINIMUM U/S UNDERSLAB EPO ETR EMERGENCY POWER OFF EXISTING TO REMAIN MLO MOCP MAIN LUGS ONLY MAXIMUM OVERCURRENT UL UNDERWRITERS LABORATORIES, INC. FACP FIRE ALARM CONTROL PANEL PROTECTION UNO UNLESS NOTED OTHERWISE FALP FIRE ALARM LOSS PREVENTION MSB MAIN SWITCHBOARD UPS UNINTERRUPTIBLE POWER SUPPLY FBO FURNISHED BY OTHERS /OWNER X LITHONIA LQM — S — W — 3R — 120/277 — EL — N — M8 1 LED — INCLUDED 0.9 0.9 120/277 WHITE PENDANT /SURFACE FF 2, 6 EM EXISTING 6V DOUBLE HEAD EMERGENCY LIGHT WITH SEALED LEAD CALCIUM BATTERY FOR 90 MINUTE OPERATION. 2 (2) 9W INC. WEDGE BASE 14 14 6 WHITE SURFACE FLR 2 XEM EXISTING EXIT SIGN COMBO WITH 6V DOUBLE HEAD EMERGENCY LIGHT WITH SEALED LEAD CALCIUM BATTERY FOR 90 MINUTE OPERATION. 2 LED — INCLUDED (EXIT) (2) 9W INC. WEDGE BASE 25 25 120/277 W SURFACE GFCI 2 NOTES: 1. "PROVIDE EMERGENCY BATTERY BACKUP TO OPERATE 1 LAMP PER 8' SECTION AT 940 LUMENS FOR 90 MINUTES FOR T5 LAMPS, AND OPERATE 2 LAMPS AT 1453 LUMENS FOR 90 MINUTES FOR T8 LAMPS. FIELD INSTALLED. 2. EMERGENCY FIXTURES SHALL BE MOUNTED AT HEIGHT REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. (SEE DETAIL 4/E101 FOR FIXTURES SUSPENDED FROM STRUCTURE.) 3. JUNCTION BOXES AND CONDUIT THAT ARE USED TO WIRE FIXTURES AND THAT ARE OPEN TO VIEW SHALL BE PAINTED TO MATCH ADJACENT STRUCTURE. 4 FIXTURE SHALL BE MOUNTED TO STRUCTURE IN A MANNER RECOMMENDED BY THE MANUFACTURER AND SO AS NOT TO COMPROMISE THE INTEGRITY OF THE STRUCTURE. 5.,FIXTURE SUSPENDED BY AIRCRAFT CABLE THAT IS MOUNTED TO UNISTRUT AT UNDERSIDE OF STRUCTURE AND SUSPENDED SUCH THAT BOTTOM OF REFLECTOR IS AT THE SAME ELEVATION AS THE EXISTING FIXTURES. CONTRACTOR TO VERIFY CABLE LENGTH. SEE DETAIL 5/E101. 6.. REFERENCE DETAIL 5/E101 FOR MOUNTING. PLUG AND PLAY J —BOX FURNISHED BY OWNER, INSTALLED BY CONTRACTOR AT JOIST SPACE. J —BOX IS FURNISHED WITH TWO MODULAR WIRING POWER CONVERTOR TAPS (6 GENERAL POWER CIRCUITS) WITH PIGTAILS IN BOX. THE CONTRACTOR SHALL CONNECT THE PIGTAILS TO THE CIRCUITS INDICATED. CONTRACTOR SHALL PROVIDE LABEL AT EACH J —BOX WITH CIRCUIT NUMBERS INDICATED IN 1/4" HIGH PRINTED LETTERS. MODULAR WIRING FROM BOX TO STORE FIXTURES IS BY OTHERS. 1HENDERSON ENGINEERS_ 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 'www.hell-eng.com 1250000367 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/12 Office Depot Approval Stamp I.G. PLUG AND PLAY J —BOX FURNISHED BY OWNER, INSTALLED BY CONTRACTOR AT JOIST SPACE. J —BOX IS FURNISHED WITH TWO MODULAR WIRING POWER CONVERTOR TAPS (3 GENERAL POWER CIRCUITS, 2 I.G. POWER CIRCUITS) WITH PIGTAILS IN BOX. THE CONTRACTOR SHALL CONNECT THE PIGTAILS TO THE CIRCUITS INDICATED. CONTRACTOR SHALL PROVIDE LABEL AT EACH J —BOX WITH CIRCUIT NUMBERS INDICATED IN 1/4" HIGH PRINTED LETTERS. MODULAR WIRING FROM BOX TO STORE FIXTURES IS BY OTHERS. �IG DUPLEX RECEPTACLE MOUNTED 18" A.F.F., U.N.O. QUADPLEX RECEPTACLE MOUNTED 18" A.F.F., U.N.O. GFCI WP /GFCI DUPLEX ISOLATED GROUND RECEPTACLE MOUNTED 18" A.F.F., U.N.O. PROVIDE INSULATED ISOLATED GROUND WIRE PER CIRCUIT. RECEPTACLE FACE SHALL BE SOLID ORANGE. QUADPLEX ISOLATED GROUND RECEPTACLE MOUNTED 18" A.F.F., U.N.O. PROVIDE INSULATED ISOLATED GROUND WIRE PER CIRCUIT. RECEPTACLE FACE SHALL BE SOLID ORANGE. GROUND FAULT DUPLEX RECEPTACLE MOUNTED 18" A.F.F., U.N.O. GROUND FAULT DUPLEX RECEPTACLE, IN WEATHERPROOF ENCLOSURE. MOUNTED 18" A.F.F., U.N.O. CI TELEPOWER POLE (SEE LEGEND E103) v DATA OUTLET MOUNTED 18" A.F.F. U.N.O. PROVIDE OUTLET BOX & CONDUIT TO JOIST SPACE /ACCESSIBLE LOCATION. v LIGHTING FIXTURE SCHEDULE TELEPHONE OUTLET MOUNTED 18" A.F.F. U.N.O. PROVIDE OUTLET BOX & CONDUIT TO JOIST SPACE /ACCESSIBLE LOCATION. Architecture Partners Architectural Design Group, Inc. 16398 NE 85TH ST. SUITE 101 Redmond, WA 98052 Telephone 425 636 -8006 www.padgi.com MEP SINGLE POLE SWITCH MOUNTED 48" A.F.F. U.N.O. SINGLE POLE SWITCH WITH OCCUPANCY SENSOR, MOUNTED 48" A.F.F., U.N.O. SINGLE POLE MOTOR RATED DISCONNECT SWITCH MOUNTED 48" A.F.F., U.N.O. JUNCTION BOX MOUNTED 42" A.F.F., U.N.O.. ELECTRICAL PANEL BOX Henderson Engineers, Inc. 8325 Lenexa Drive Lenexa, KS 66214 Telephone 913.742.5000 Fax 913.742.5001 www.hei- eng.com Revisions / Issues REV DATE DESCRIPTION ELECTRIC MOTOR 3.6.12 BLDG. PERMIT SUBMITTAL 4.2.12 SCOPE REDUCTION 60 3/35 DISCONNECT SWITCH — "60/3/35" DENOTES AMPERES /POLE /FUSE NF= NON -FUSED CB= CIRCUIT BREAKER (35/3/CB) D PUSH — BUTTON RECEIVING DOOR, EDWARDS #1786C —B PUSH — BUTTON VESTIBULE DOOR, EDWARDS #852 DOOR BELL OR BUZZER WIRELESS DEVICE BY OTHERS. FDR CONDUIT /WIRE FEEDER TAG EMERGENCY LIGHT FIXTURE GROUNDS iNEUTRAL ISOLATED GROUND SWITCH GROUND ISOLATED GROUND HOTS NEUTRAL SWITCH HOTS CIRCUIT, CONCEALED IN WALL OR CEILING CIRCUIT, EXPOSED RECEIVED APR 13 2012 PERMITCENTER NO SCALE WHEN USING! .KINDORF OR UNISTRUT FOR SUPPORT, USE ONLY CONTINUOUS SECTIONS. NO SPLICING OF MULTIPLE PIECES IS PERMITTED. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2008 EDITION OF THE NATIONAL ELECTRICAL CODE WITH WASHINGTON STATE AMENDEMENTS AND ALL CODES HAVING LOCAL JURISDICTION. COORDINATE WITH OTHER CONTRACTORS FURNISHING EQUIPMENT TO VERIFY LOADS AND SECURE LOCATION OF OUTLETS, JUNCTION BOXES, ETC.. FURNISH AND /OR INSTALL DISCONNECT SWITCHES, STARTERS, AND ASSOCIATED WIRING AS REQUIRED BY MANUFACTURER SPECIFICATIONS FOR EXHAUST FANS AND AIR CONDITIONING EQUIPMENT. MINIMUM WIRE SIZE SHALL BE #12 AWG EXCEPT CONTROL WIRING AS NOTED. ALL WIRE SHALL BE COPPER TYPE THWN OR THHN. A. ALL 120 VOLT CIRCUITS OVER 75 FEET IN LENGTH SHALL BE #10 AWG. B. ALL WIRING FOR LIGHTING SHALL BE MINIMUM #10 AWG U.N.O.. ALL ELECTRICAL SYSTEMS. SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED IN, ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE SERVICE ENTRANCE SHALL BE INSTALLED PER THE NATIONAL ELECTRICAL CODE AND THE LOCAL UTILITY WHEN REQUIRED BY THE A.H.J.. UNLESS OTHERWISE NOTED, ALL WIRING DEVICES SHALL BE INSTALLED AS FOLLOWS: A) WALL SWITCHES AT 48 A.F.F. B) DUPLEX RECEPTACLES AT 18" A.F.F. C) TELEPHONE OUTLETS AT 18" A.F.F. VERIFY CEILING CONSTRUCTION WITH GENERAL CONTRACTOR BEFORE INSTALLING LIGHT FIXTURES. 10. SECURE LOW VOLTAGE CABLE IN JOIST SPACE NEATLY TO STRUCTURE. PROVIDE 3/4" CONDUIT STUBS (WITH PULL STRINGS) AND JUNCTION BOXES FROM POINT OF USE TO ROOF STRUCTURE. PROVIDE PLASTIC BUSHINGS AT OPEN END OF CONDUIT. ALL EXPOSED CABLING SHALL BE PLENUM RATED AND SHALL MATCH COLOR OF PAINTED ROOF STRUCTURE. 11. IF APPLICABLE, ELECTRICAL CONTRACTOR SHALL INCLUDE ELECTRICAL DEMOLITION. SEE ARCHITECTURAL DEMOLITION PLAN(S) FOR ADDITIONAL NOTES. 12. VERIFY MECHANICAL EQUIPMENT OVERCURRENT PROTECTION REQUIREMENTS WITH THE EQUIPMENT MANUFACTURER PRIOR TO CONNECTION. 13. ELECTRICAL CONTRACTOR SHALL VERIFY ALL LIGHT FIXTURE LOCATION DIMENSIONS WITH OFFICE DEPOT'S FIXTURE PLANS. 14. SEE PANEL SCHEDULES FOR CIRCUIT BREAKER, WIRE, AND CONDUIT REQUIREMENTS. 15. ALL CONDUIT SHALL BE 3/4" UNLESS NOTED. 16. ALL EXIT, EMERGENCY, AND NIGHT LIGHTS SHALL BE ON A NON— SWITCHED BREAKER OR CONNECTED AHEAD OF THE SWITCH AS PER PLANS. 17. ROUTE ALL EXPOSED HORIZONTAL CONDUIT IN JOIST SPACE TIGHT TO TOP CHORD, NO EXCEPTIONS. WHERE CONDUIT MUST DROP BELOW BEAMS, KEEP TIGHT TO BEAM & AS UNOBTRUSIVE AS POSSIBLE. 18. ELECTRICAL CONTRACTOR SHALL CONNECT ALL SIGNS AND AUTOMATIC DOORS AS REQUIRED PER MANUFACTURER SPECIFICATIONS. 19. ROUTE NEUTRAL CONDUCTOR, SAME SIZE AS PHASE CONDUCTORS, WITH ALL FEEDERS AND BRANCH CIRCUITS EXCEPT TRANSFORMER FEEDERS, RTU FEEDERS, BALER, AND COMPACTOR. 20. ALL TELEPHONE, COMPUTER, & SECURITY SYSTEM LOW VOLTAGE WIRING IS FURNISHED & INSTALLED BY OTHERS. 21. ALL LINE VOLTAGE WIRING AND ALL EMS WIRING IS PROVIDED BY ELECTRICAL CONTRACTOR. ALL CONDUIT IS PROVIDED BY THE ELECTRICAL CONTRACTOR WITH PULL STRING IN EMPTY CONDUITS. 22. REFER TO OFFICE DEPOT SITE SPECIFIC FIXTURE PLAN FOR DATA & TELEPHONE NUMERICAL DESIGNATION, LOCATIONS, ETC. 23. FOR ALL POWER POLE LOCATIONS, ELECTRICAL CONTRACTOR SHALL FURNISH UNISTRUT TO SUPPORT THE TOP OF THE POWER POLE. POWER POLE ITSELF WILL BE FURNISHED AND INSTALLED BY OFFICE DEPOT. CONTRACTOR SHALL FURNISH THIRTY (30) EIGHT FOOT LENGTHS OF UNISTRUT, PAINTED (SEE ARCHITECT'S FINISH PLAN FOR COLOR), WITH MOUNTING HARDWARE FOR INSTALLATION BY OFFICE DEPOT. 24. ALL CURRENT CARRYING CONDUCTORS, EXCEPT LOW VOLTAGE CONDUCTORS, SHALL BE RUN IN CONDUIT. 25. MC CABLE IS NOT TO BE USED FOR ANY VERTICAL DROP LOCATED ON THE SALES FLOOR. THE MC CABLE IS TO BE SUPPORTED & FASTENED PER THE NEC. THE CABLE IS TO BE PAINTED TO MATCH SURROUNDING SURFACE. 26. ALL DEVICES & COVER PLATES SHALL BE WHITE. ISOLATED GROUND RECEPTACLES SHALL BE ORANGE. 27. COORDINATE SIGN CONNECTIONS WITH SIGN SUPPLIER /CONTRACTOR. 28. ELECTRICAL FEEDS TO ALL PANELS, TRANSFORMERS, BRANCH CIRCUITS, ETC. IN OFFICE DEPOT SHALL BE RUN OVERHEAD ONLY. 29. GROUNDING OF ELECTRICAL EQUIPMENT BY ELECTRICAL CONTRACTOR SHALL CONFORM WITH NATIONAL AND LOCAL ELECTRICAL CODES. 94 1 REVIEWED .FUN COMPLIANCE WITH NFPA70 • NEC APR 19 2012 Clay Tukwila BUILDING DIVISION ELECTRICAL GENERAL NOTES NO SCALE ? SYMBOL LIST NOTES: 1. SYMBOL LIST SHOWN IS FOR GENERAL REFERENCE ONLY. THE PRESENCE OF A SYMBOL DOES NOT IMPLY ITS USE ON THIS PROJECT. REFER TO DRAWINGS FOR SPECIFIC SYMBOLS USED. ABBREVIATIONS A AMPERES, AIR (COMPRESSED) GFR GROUND FAULT RELAY OS OCCUPANCY SENSOR A/C AIR CONDITIONING G GROUND PART PARTIAL CIRCUIT AF AMPERE FUSE GND GROUND PH, 0 PHASE AFC ABOVE FINISHED CEILING GRMC GALVANIZED RIGID METAL PNL PANEL AFCI ARC FAULT CIRCUIT INTERRUPTER CONDUIT PNLBD PANELBOARD AFF ABOVE FINISHED FLOOR GRS GALVANIZED RIGID STEEL PROVIDE FURNISH AND INSTALL AFG ABOVE FINISHED GRADE IG ISOLATED GROUND PT POTENTIAL TRANSFORMER AHJ AUTHORITY HAVING JURISDICTION ISC SHORT CIRCUIT CURRENT QTY QUANTITY Al ANALOG INPUT JB JUNCTION BOX RCPT RECEPTACLE AIC AMPERE INTERRUPTING CURRENT J —BOX JUNCTION BOX RLA RUNNING LOAD AMPS AL ALUMINUM kcmil 1000 CIRCULAR MILS RTU ROOFTOP UNIT AO ANALOG OUTPUT KK KIRK KEY SD SMOKE DETECTOR, SUPPLY DUCT AP ACCESS PANEL kV KILOVOLT SF SQUARE FEET, SUPPLY FAN AWG AMERICAN WIRE GAUGE kVA KILOVOLT —AMPS SPDT SINGLE —POLE, DOUBLE —THROW BKR BREAKER kVAR KILOVOLT —AMPS REACTIVE SPST SINGLE —POLE, SINGLE —THROW c CONDUIT kW KILOWATT SS STAINLESS STEEL, SANITARY CD CANDELA kWH KILOWATT —HOUR SEWER, SOIL STACK CT CURRENT TRANSFORMER LF LINEAR FEET ST SHUNT TRIP, STEAM TRAP CAN CABLE TELEVISION SYSTEM MAX MAXIMUM SWBD SWITCHBOARD CCTV CLOSED CIRCUIT TELEVISION MCA MINIMUM CIRCUIT AMPACITY TL TWISTLOCK CKT CIRCUIT MCB MAIN CIRCUIT BREAKER TR TAMPER RESISTANT CU COPPER, CONDENSING UNIT MD MOTORIZED DAMPER TX TRANSFORMER CVD CUMULATIVE VOLTAGE DROP MDP MAIN DISTRIBUTION PANEL TYP TYPICAL DN DOWN MFR MANUFACTURER U/F UNDERFLOOR DPDT DOUBLE —POLE, DOUBLE —THROW MG MOTOR GENERATOR • U/G UNDERGROUND DPST DOUBLE —POLE, SINGLE —THROW MH MANHOLE UH UNIT HEATER EM EMERGENCY MIN MINIMUM U/S UNDERSLAB EPO ETR EMERGENCY POWER OFF EXISTING TO REMAIN MLO MOCP MAIN LUGS ONLY MAXIMUM OVERCURRENT UL UNDERWRITERS LABORATORIES, INC. FACP FIRE ALARM CONTROL PANEL PROTECTION UNO UNLESS NOTED OTHERWISE FALP FIRE ALARM LOSS PREVENTION MSB MAIN SWITCHBOARD UPS UNINTERRUPTIBLE POWER SUPPLY FBO FURNISHED BY OTHERS /OWNER MSWB MAIN SWITCHBOARD V VOLT(S) FCA FAULT CURRENT AMPS MTD MOUNTED ` VAC VOLTS ALTERNATING CURRENT FF FINISHED FLOOR N/A NOT APPLICABLE VD VOLTAGE DROP FLA FULL LOAD AMPS N/C NORMALLY CLOSED VDC VOLTS DIRECT CURRENT FLR FLOOR NIC NOT IN CONTRACT VFD VARIABLE FREQUENCY DRIVE GC GENERAL CONTRACTOR NL NIGHT LIGHT W WIRE GFCI GROUND FAULT CIRCUIT N/O NORMALLY OPEN WP WEATHERPROOF INTERRUPTER OC ON CENTER WR WEATHER RESISTANT XP EXPLOSION —PROOF Offwe DEPOT Wit" CatrefOsamers BUY GREEN SELL GREEN BE GREEN 2010 PROTOTYPE OD STORE #XXXX 6600 North Military Trail N278 Boca Raton, FL 33496 TEL: 561/438 -6299 FAX: 561/438-7237 Seal Project Title Office Dept #0984 300 Andover Park W #400 Tukwila, WA 98188 Gross Tenant Area: 22,199 sq. ft. Job Number ELECTRICAL SYMBOLS & ABBREVIATIONS NO SCALE NOTE EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS— BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. Drawing SCHEDULES, NOTES, & LEGEND Scale AS NOTED ON DRAWING Drawing Date 3.6.12 PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THESE DRAWINGS. Drawing No. E301 CRAIG R. LANHAM ETR ETR EM /C1A C2 01 C2 C1 C2 C1 ETR C2 ETR /EM ETR /EM ETR /EM ETR * * * * * * * * * ETR PANELBOARD: MDP (EXISTING) ** FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 600A AIC RATING: 18000 FULLY RATED MAIN SIZE /TYPE: MLO SERVES: TENANT VOLTS /PHASE: 480Y/277V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: ELECTRICAL ROOM CKT L DESCRIPTION NO. VOLTAMPS /PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS /PHASE DESCRIPTION CKT NO. A B C A B C 1 SURGE PROTECTIVE DEVICE (SPD) „V // j / / /// j�/ ETR 60 3 3 10 960 / , /� // j // 2 SPACE SPARE 3 7/ j// / 20 1 4 5 /�� //�/7/ 1,200 / 4 5 6 7 DEDICATED SPACE ETR / /// ;; XX XX X 3 150 ETR 22,066 �� / PNLBD PB VIA 112.5 KVA XFMR T1 8 9 /Z0; 13. 2 %// Pr 28,100 Z��A, 10 11 /, %/ ;�/ j 8 rr r/ 25,136 12 13 PNLBD LA 13,462 / j �,��� ETR 125 3 3 //// / SALES LTG ROWS 5/6 10 / SPACE 14 15 / / 10,657 7�,�// �j/�j�Z 10 ����ir 16 17 //, ��/ j/ 11,477 / / /// / / 18 1.9 DEDICATED SPACE 1 / / / /// / V % / XX XX X 3 400 ETR 68,682 / PNLBD C 20 21 War 65,402 ����Z 22 ///, // j LTG ROWS 7/8/9 +EM LTG 23 24 / , / /,/ /f // ' �, /// / ETR 65,546 25 SPACE • 20 mil/ /'� � 2:- ,//////, 7 / SPARE 3 3 132 �� /// �/ !�� /. 'f /,/ SPACE 26 27 /, 32 28 %7&/ 29 30 % % /'/i %Z'// ' 1 / / / SUBTOTAL 13,462 10,657 11,477 10 90,748 93,502 90,682 SUBTOTAL TOTAL PHASE A - VA 104,210 LOAD CONN. VA DF ETR LOAD CONN. VA DF 20 REFRIGERATION / //// 1.00 COOLING 24 1.00 AMPS 376 HEATING j / 0 SIGN /DISPLAY 1 1.25 TOTAL PHASE B - VA 104,159 AMPS 376 LIGHTING 1,040 1.25 KITCHEN / // / 1.00 EXISTING 287,204 1.00 RECEPTACLES 19,980 1.0/.5 TOTAL PHASE C - VA 102,159 MOTORS OFFICE /RR /LOUNGE LTG 1.00 LARGE MOTOR PWR CTR LTG 1.25 TOTAL DEMAND 132 AMPS 369 SHOW WINDOW 1 1.25 305,798 VA SUPP HEAT /2,132 / 1.00 TOTAL PNLBD - VA 310,528 MISC EQUIP 2,304 1.00 LTG TRACK 1 1.00 368 A AMPS 374 PANELBOARD NOTES ETR - EXISTING TO REMAIN LTG TRACK - TRACK LENGTH ** - ALL CIRCUIT BREAKERS ARE EXISTING TO REMAIN. SIGN /DISPLAY - SIGNAGE & DISPLAY CASE PANELBOARD: LA (EXISTING) ** FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 250A AIC RATING: 14000 FULLY RATED MAIN SIZE /TYPE: MLO SERVES: TENANT VOLTS /PHASE: 480Y/277V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: ELECTRICAL ROOM CKT NO. DESCRIPTION VOLTAMPS /PHASE NO. AMP P P BKR VNIORE VO AMPB /PHASE DESCRIPTION NO. A C A � C RTU -1 (1 1 -0) COPY /VESTIBULE LTG +EM LTG 1,958 „V // // 10 20 1 1 20 10 960 / , /� // SALES LTG ROWS 1 /2 2 3 SPARE / /, /// 4 j// �; //j 20 1 1 20 10 7/// 1,200 / SALES LTG ROWS 1/2+EM LTG 4 5 SPARE / /f,/ / j „/ ETR 8,342 20 1 1 20 10 4,683 WM". / j / 2,160 SALES LTG ROWS 3/4 . 6 7 SPARE 4,683 „ // / j 13. 20 1 1 20 10 2,160 //% / SALES LTG ROWS 3 /4 +EM LTG 8 9 SPARE / "/ " / 14 / Wr Ad 20 1 1 20 10 / / / 2,160 //// / SALES LTG ROWS 5/6 10 11 SPARE - j„ / / / � ETR 20 1 1 20 10 j// / j 2,160 SALES LTG ROWS 5 /6 +EM LTG 12 13 SPARE 8,342 ��Ar / /// / / 22 20 1 1 20 10 2,640 jj �/„ SALES LTG ROWS 7/8/9 /SALES 14 15'` SPARE ///////- // 20 20 1 1 20 10 / // 2,400 j LTG ROWS 7/8/9 +EM LTG 16 17 . EXISTING LOAD S -ARE __WOW �, /// 1,000 ETR 20 1 1 20 30 / / SPARE 18 19 PCX ROOM LTG 132 �� ree;/ / ETR 20 1 1 20 32 33 �ZdIX SPARE 20 21 SPARE ;; i; / j 1 / / / /// / 20 1 1 20 10 ! // 2,715 /, // RECEIVING LTG 1 22 23 NIGHT /EMERG. LTG f 020 j /, // 1,840 ETR 20 1 1 20 10 / //// / / /`/ 2,125 RECEIVING LTG 2 +EM LTG 24 25 NIGHT /EMERG. LTG 482 /, %,/ j / ETR 20 1 1 20 ETR 3,070 SUBTOTAL MEZZ. OFFICE LTG j�f 26 27 NIGHT /EMERG. LTG / // / 50 % / /// ETR 20 1 1 20 ETR / / CONN. VA OFFICE /RR /LOUNGE LTG 28 29 PWR CTR LTG / / /,� / 132 ETR 20 1 1 20 ETR �j/ /2,132 / 2,060 MEZZANINE LTG 1 30 3 1 SPACE AMPS / / / /f,,1 LIGHTING 1 1.25 ETR 1 20 ETR 2,060 , /,� MEZZANINE LTG 2 32 33 SPACE / J %„ �� 1.00 �!/ �, 237 MOTORS 1 1 LARGE MOTOR 47 / / / % TOTAL DEMAND Vj /j SPACE 34 35 SPACE // / /�� //jj « // 1.25 199,630 VA 1 1 MISC EQUIP 2,304 2/ / / ,/„ SPACE 36 37 SPACE 180 ;i' �, /�f , J'i i/ 50 51 1 1 1,440 i / ,,, 10 20 1 / / '' / SPACE 38 39 SPACE. „�/ 52 �/ PLUG & PLAY BOX - T /22 1 1 1 1 , ��/ ETR / / / /// SPACE 40 4.1 SPACE /// / / /// / 1,440 2 /7/,j%/2 10 20 1. 1 20 ETR 500 / / /%/ SPACE 42 SUBTOTAL 2,572 50 1 2,972 20 10,890 10,607 I- 8,505 SUBTOTAL TOTAL PHASE A - VA 13,462 LOAD CONN. VA DF 59 LOAD CONN. VA DF AMPS 49 COOLING 20 1.00 REFRIGERATION j 1.00 SIGN /DISPLAY 61 1.25 TOTAL PHASE B - VA 10,657 HEATING 1 0 KITCHEN ETR 1.00 AMPS 38 LIGHTING 63 1.25 RECEPTACLES / 1,440 10 1.0/.5 EXISTING 35,596 1.00 TOTAL PHASE C - VA 11,477 AMPS 41 MOTORS 89 1.00 LARGE MOTOR 4/, 1.25 TOTAL DEMAND SHOW WINDOW 20 1.25 35,596 VA TOTAL PNLBD - VA 35,596 SUPP HEAT 1.00 1.00 LTG TRACK 1 ,440 1.00 43 A AMPS 43 MISC EQUIP 20 1.00 PANELBOARD NOTES C# - VIA LTG CONTACTOR # EM - EMERG LTG HANDLE -ON CLAMP ETR - EXISTING TO REMAIN ** - ALL CIRCUIT BREAKERS ARE EXISTING TO REMAIN. LTG TRACK - TRACK LENGTH * ** - TRACE EXISTING CIRCUIT, IDENTIFY LOAD. SIGN /DISPLAY - SIGNAGE & DISPLAY CASE PANELBOARD: C (EXISTING) ** FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 400A AIC RATING: 14000 FULLY RATED MAIN SIZE /TYPE: MLO SERVES: TENANT VOLTS /PHASE: 480Y/277V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: ELECTRICAL ROOM CK NOT DESCRIPTION VOLfAMPB /PHASE NIOE AMP P P BKR AMP W NOIRE VOLTAMPS /PHASE DESCRIPTION NO. A I I C A B C 1 RTU -1 (1 1 -0) 4,683 / / ETR 20 3 3 40 ETR 8,342 i i RTU -5 (10 -B) 2 3 , MI 4,683 V Ar r 'Ar 8,342 r ���J 4 5 �; //j 4,683 / /2 8,342 6 7 RTU -2 (10 -C) 4,683 / ,/ ETR 20 3 3 40 ETR 8,342 ! RTU -6 (11-A) 8 9 �yj� 4,683 WM". w A / 8,342 ry��4, 10 6 // 4,683 8,342 12 13. RTU -3 (9 -C) 4,683 �i ETR 20 3 3 40 ETR 8,342 r / (10 -A) 14 15 Wr Ad 4,683 G��A 8,342 VAN FA 16 17 // / 4,683 r A 8,342 18 19 RTU -4 (11 -B) 8,342 / � ETR 40 3 3 40 Mil WirA/ / SPARE 20 21 FA M/ 8,342 ��Ar Wr AA Ij,� rr 22 23 / / IN -RACK LTG WEST 680 20 12 25 BULE HEATER 4 /8,342 -I ETR 20 1 3 20 ETR IN -RACK LTG EAST RCPTS - MEZZAININE OFFICE RCPTS- MEZZANINE OFFICE RCPTS- MEZZANINE OFFICE �/ PHASE LOSS MONITOR 26 27 SPARE r A 5 `'j, 28 9. S -ARE __WOW UPB1 r4V401411011e, 0 1 V A% % 5 30 3.1 PNLBD PD VIA 75KVA XFMR T2 9,780 ryVM PirZ OL 100 3 3 40 ETR 7,480 ��I /Ir //Z ELEVATOR 32 33 VIM 10,500 A 7,480 W�Z 20 3 1 � 10,644 / / 7,480 _34 36 7 SPARE �D ., I �A / ' 40 3 1 1 1 20 / � Fr SPACE 38 39 PLUG & PLAY BOX - P 34 V �� r 1 WANIESWAV j // j , // �/ SPACE 40 41 /� / i. /i, / 1 540 PLUG & PLAY BOX - P 36 �� / SPACE 42 SUBTOTAL 36,171 32,891 1 33,035 / // 32,511 32,511 32,511 SUBTOTAL TOTAL PHASE A - VA ' 68,682 LOAD CONN. VA DF / ' /, LOAD CONN. VA DF / // PLUG & PLAY BOX - K SPACE AMPS 248 COOLING / j�„ 1.00 REFRIGERATION 10 1.00 TOTAL PHASE B - VA 65,402 HEATING .�: 0 SIGN /DISPLAY SPARE 1.25 AMPS 236 LIGHTING 1 1.25 ETR KITCHEN „ /// 1.00 TOTAL PHASE C - VA 65,546 RECEPTACLES 6,120 1.0/.5 EXISTING 191,206 1.00 AMPS 237 MOTORS 800 1.00 LARGE MOTOR 47 1.25 TOTAL DEMAND TOTAL PNLBD - VA 199,630 SUPP HEAT 1 1.00 SHOW WINDOW « // 1.25 199,630 VA AMPS 240 MISC EQUIP 2,304 1.00 LTG TRACK 1 1.00 240 A PANELBOARD NOTES ETR - EXISTING TO REMAIN OL - REFER TO ONE -LINE DIAGRAM ** - ALL CIRCUIT BREAKERS ARE EXISTING TO REMAIN U.N.O. ** - 4 , Fe ' ' MOCP AND REPLACE CIRCUIT BREAKER AS REQUIRED. LTG TRACK - TRACK LENGTH SIGN /DISPLAY - SIGNAGE & DISPLAY CASE ETR ETR 01 EM /C2 01 EM /C2 01 EM /C2 01 C2 01 C2A C 1 A EM /C1A ETR /C1A ETR /C1A ETR /C1A ETR /C2A ETR ETR ETR ETR ETR ETR ETR ETR ETR HT1 HT1 HT1 C1B C1B ETR ETR ETR ETR ETR ETR ETR HT2 HT2 HT2 HT3 HT3 HT3 HT4 HT4 HT4 HT5 HT5 HT5 ETR ETR ETR ETR PANELBOARD: PB (EXISTING) ** FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 400A AIC RATING: 10000 FULLY RATED ISOLATED GROUND BUS MAIN SIZE /TYPE: 300A MCB SERVES: TENANT VOLTS /PHASE: 208Y/120V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: ELECTRICAL ROOM CKT ( NO. DESCRIPTION VOLTAMPS /PHASE WIRE NO. BKR' P AMP P BKR AMP WIRE NO. VOLTAMPS /PHASE DESCRIPTION CKT NO. A B C A 1 B C 1 TELEPHONE RCPT 300 / �/!// ETR 20 1 1 20 ETR 1,500 / ,,/ // 7 LOUNGE COUNTER RCPT 2 3 TELEPHONE RCPT j/ / 300 /7/0 ETR 20 1 1 20 ETR 1,500 f/ // LOUNGE COUNTER RCPT 4 5 UPS / V/ / , %/ 300 ETR 20 1 1 20 ETR / /�/ / / / 1,200 REFRIGERATOR 6 7 SPARE 6 // / / 20 1 3 50 ETR 2,906 1 / 8 9 FORKLIFT CHARGER yy� 3,890 rerZOIA ETR 50 2 r A 2,906 r A COMPACTOR 10 11 WrAURINAI 20 3,890 A,r r A 2,906 12 13 15 17 PLUG & PLAY BOX - N PLUG & PLAY BOX - N PLUG & PLAY BOX - N 180 lardinriKall 180 10 ��� 10 180 10 20 20 20 1 1 1 1 1 1 20 20 20 Mil 1 :00 w_ ��A /� /� : I� ETR �j�A ���� 7 0 PIr, i����/ri� MAR. OFFICE RCPTS KW 1,000 COMPUTER al 19 IN -RACK LTG WEST 680 20 12 20 1 1 20 � 3.0 II%� /��_ v I�4 ����e RTU R P S QM 21 23 25 27 IN -RACK LTG EAST RCPTS - MEZZAININE OFFICE RCPTS- MEZZANINE OFFICE RCPTS- MEZZANINE OFFICE IMPFAMIWANI 900 360 swasiman 900 12 900 ETR ETR RIME ETR 20 20 20 20 1 1 1 1 1 1 1 1 20 20 20 20 ETR R ETR ETR �/��A w_ _4eiii 680 864 /�i_ Pi Awry UPB1 7 0 r4V401411011e, A CASH RM RCPTS sir P'��r 720 A� 4 ENERAL RCPTS CAI 29 RCPTS- MEZZANINE OFFICE / /, j / f 720 ETR 20 1 1 20 ETR / 1 720 GENERAL RCPTS 30 31 RCPTS- MEZZANINE OFFICE 720 j� ;/ 2;020 ETR 20 1 1 20 10 540 / j PLUG & PLAY BOX - P 32 33 RCPTS- MEZZANINE OFFICE / ' 720 // // / ETR 20 1 1 20 10 / 540 20 PLUG & PLAY BOX - P 34 35 PLUG & PLAY BOX - U WANIESWAV j // 360 20 3 1 20 10 / / 540 PLUG & PLAY BOX - P 36 360 1 10 1 20 10 180 / // / PLUG & PLAY BOX - V 38 1// 1,200 ;! 1 20 10 / ' /, 180 j PLUG & PLAY BOX - V 40 / // PLUG & PLAY BOX - K SPACE 29 _ _ _ _ mingompIa / j�„ 1 20 10 , ornr r A 180 PLUG & PLAY BOX - V 10 .�: / / �/ 43 SPARE 31 % „j % %,i /1 j 20 1 1 20 ETR 300 „ /// / NOVAR RMS. 2 44 45 RESTROOM EXHAUST j,,/ 500 /, /,/ ETR 20 1 1 20 ETR 10 800 j// EXHAUST FANS 46 47 ELEVATOR EQUIPMENT jj j i� 1,500 ETR 20 1 1 20 ETR « // 1,200 360 RECEIVING AREA RCPTS 48 49 PLUG & PLAY BOX - T 1,440 / / j��% ,/, / 10 20 1 1 20 ETR 180 V// / 2, ELEVATOR ROOM RCPT 50 51 PLUG & PLAY BOX - T / ,�/, 1,440 i / ,,, 10 20 1 1 20 ETR j, 300 ��/ NOVAR BMS. 1 52 53 PLUG & PLAY BOX - T /22 %, %/ 1,440 10 20 1 1 20 ETR ,j/ j/ 200 ELECTRICAL ROOM EF 54 1 55 PLUG & PLAY BOX - S 1,440 2 /7/,j%/2 10 20 1 1 20 ETR 500 j/ PCX ROOM RCPT 56 57 PLUG & PLAY BOX - S / /j, 1,440 7,/,/ 10 20 1 1 20 ETR / j 720 jj/ RECEIVING OFFICE RCPTS 58 59 PLUG & PLAY BOX - S �0 •27 /f� 10 20 1 1 20 ETR jj/ j 720 RECEIVING OFFICE RCPTS 60 61 PLUG & PLAY BOX - R 1,440 //,440 %2/ ,/ 10 20 1 1 20 ETR 720 j / j RECEIVING OFFICE RCPTS 62 63 PLUG & PLAY BOX - R / / 1,440 10 20 1 1 20 ETR / 200 EMPLOYEE LOUNGE FAN 64 89 PLUG & PLAY BOX - R / 4/, LARGE MOTOR 1.25 TOTAL DEMAND 20 TOTAL PNLBD - VA / 500 A& N SERVER 1.00 I PLUG & PLAY BOX - Q 1 ,440 // 10 20 1 1 20 10 1,080 A / PLUG PLAY - 0 'I Milk PLUG & PLAY BOX - Q WM 1,440 �,I � %te 10 20 1 1 20 10 r A 1,080 r A PLUG & PLAY BOX - 0 WINK OWk:Y11410 rQ/, /�_44W/� 2,000 i�LIPIIII 20 I 30 1 2 1 1 20 20 10 ETR ����� 720 r A / 1,080 PLUG & PLAY BOX - 0 MEZZANINE RCPTS 72 74 r I �/� A 73 WATER HEATER ��_��_ 2,000 1 20 ETR / 900 �i MEZZANINE RCPTS 76 BM t d y- - ;J _� � /�jdfilligi 20 1 1 20 ETR r A r A 900 MEZZANINE RCPTS 78 79 ELEVATOR SHAFT PLUG 500 // / , // ETR 20 1 1 20 / SPARE 80 81 ELEVATOR SHAFT / / /,/ 1,200 ;'Z % // ETR 20 1 1 20 ETR //j/ 500 /EXISTING LOAD 82 83 SPARE Jf %/, %�,% 20 1 1 20 ETR , /// 7,//�/ 500 FURNITURE RCPT /DOOR ALARM 84 SUBTOTAL I. 11,400 16,170 13,610 10,666 11,930 11,526 SUBTOTAL TOTAL PHASE A - VA 22,066 LOAD CONN. VA DF LOAD CONN. VA DF COOLING 1.00 REFRIGERATION 1.00 AMPS 184 TOTAL PHASE B - VA 28,100 HEATING 0 SIGN /DISPLAY 1.25 LIGHTING 1,040 1.25 AMPS 234 KITCHEN 1.00 TOTAL PHASE C - VA 25,136 RECEPTACLES 13,860 1.0/.5 EXISTING 60,402 1.00 AMPS 209 MOTORS 1.00 LARGE MOTOR 1.25 TOTAL DEMAND TOTAL PNLBD - VA 75,302 SUPP HEAT 1.00 SHOW WINDOW 1.25 73,632 VA AMPS 209 LTG TRACK 1.00 204 A MISC EQUIP 1.00 PANELBOARD NOTES - H- 1 • : •C.,: -0 13 C A FEED THRU CONNECTION: (2) Sets of #3/0 R - EXIS NG Ti REMAIN C# - VIA LTG CONTACTOR HT# - PROVIDE HANDLE -TIE FOR MULTI -WIRE BRANCH CIRCUIT ** - ALL CIRCUIT BREAKERS ARE EXISTING TO REMAIN U.N.O. LTG TRACK - TRACK LENGTH * ** - NEW CIRCUIT BREAKER SIGN /DISPLAY - SIGNAGE & DISPLAY CASE ETR. ETR ETR ETR ETR HT6 HT6 HT6 HT7 HT7 HT7 ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR HT8 HT8 HT8 ETR ETR ETR ETR ETR HT1 HT1 HT1 HT2 HT2 HT3 HT3 HT4 HT4 * * /C5 * * /C5 * * /C5 * * /C5 HT5 HT5 HT5 HT6 HT6 * ** /HT6 PANELBOARD: PD (RELOCATED) ** FAULT CURRENT: REFER TO ONE -LINE DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 250A AIC RATING: 10000 FULLY RATED ISOLATED GROUND BUS MAIN SIZE /TYPE: 225A MCB SERVES: FRONT OF STORE VOLTS /PHASE: 208Y/120V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: FRONT WALL CKT NO. DESCRIPTION VOLTAMPS /PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS /PHASE DESCRIPTION CKT NO. A r B C A B C 1 PLUG & PLAY BOX - A,B,C 360 0/ / /,/ / // ,, 10 20 1 1 20 10 1,200 / �� „/ 7 PLUG & PLAY BOX - D 2 3 PLUG & PLAY BOX - A,B,C / % 360 10 20 1 1 20 10 j /, 360 0 PLUG & PLAY BOX - D 4 5 PLUG & PLAY BOX - A,B,C j// / / , / 1,464 10 20 1 1 20 10 /j 360 PLUG & PLAY BOX - D 6 7 PLUG & PLAY BOX - A,B,C (IG) 1,080 / // 10 20 1 1 20 10 720 �/ j PLUG & PLAY BOX - E.F � 8 9 PLUG & PLAY BOX - A,B,C (IG) / , / 1,080 ,// 10 20 1 1 20 10 , 900 / PLUG & PLAY BOX - E,F 10 11 FRONT DOOR OPENER j/7/ f/ // 720 12 20 1 1 20 10 j�/ j 720 PLUG & PLAY BOX - E,F 12 13 FRONT DOOR OPENER 720 % /X / /�� /f/ 12 20 1 1 20 10 1,080 • /,/ / PLUG & PLAY BOX - G 14 15 PLUG & PLAY BOX - K (IG) / / 1,080 %////// 10 20 1 1 20 10 / 1,080 /f PLUG & PLAY BOX - G 16 17 PLUG & PLAY BOX - K (IG) j / j, / 1,080 10 20 1 1 20 10 jj/ j 1,080 PLUG & PLAY BOX - G 18 19 PLUG & PLAY BOX - E (IG) 360 // j /� 10 20 1 1 20 10 1,260 / / / / PLUG & PLAY BOX - J 20 21 PLUG & PLAY BOX - E (IG) / /,/ 360 / /////2 10 20 1 1 20 10 / j 240 �/ PLUG & PLAY BOX - J 22 23 STOREFRONT SIGN ,j� / j�� 1,200 12 20 1 1 20 10 j // 180 PLUG & PLAY BOX - J 24 25 STOREFRONT SIGN 1,200 ////// / jj 12 20 1 1 20 10 360 f� j PLUG & PLAY BOX - K 26 27 STOREFRONT SIGN 1// 1,200 /i 12 20 1 1 20 10 j 360 / // PLUG & PLAY BOX - K 29 STOREFRONT SIGN / j�„ 1 200 12 20 1 1 20 10 /�/ / / �/ 360 PLUG & PLAY BOX - K 30 31 PLUG & PLAY BOX - H 360 / 2/ / j / i 10 20 1 1 20 10 720 / j PLUG & PLAY BOX - M 32 33 PLUG & PLAY BOX - H / j,/ 360�j 10 20 1 1 20 10 / // 720 ��/ PLUG & PLAY BOX - M 34 35 PLUG & PLAY BOX - H % /7/ / j „4/4 1,200 10 20 1 1 20 10 %�`/ / /� 720 PLUG & PLAY BOX - M 36 37 PLUG & PLAY BOX - 1 //,/,/ ' /Z7 10 20 1 1 20 10 180 j�j� / /� PLUG & PLAY BOX - L 38 39 PLUG & PLAY BOX - I //180 / 2/ � 1,200 , // 10 20 1 1 20 10 / 1,200 � / PLUG & PLAY BOX - L 40 41 PLUG & PLAY BOX - I / / // / ///0 180 10 20 1 1 20 10 // / ,,,,,/ 180 PLUG & PLAY BOX - L 42 SUBTOTAL 4,260 5,640 7,044 5,520 4,860 3,600 SUBTOTAL TOTAL PHASE A - VA 9,780 LOAD CONN. VA DF LOAD CONN. VA DF AMPS 82 COOLING 1.00 REFRIGERATION 1.00 TOTAL PHASE B - VA 10,500 HEATING 0 SIGN /DISPLAY 1.25 AMPS 88 LIGHTING 1.25 KITCHEN 1.00 TOTAL PHASE C - A 10,644 RECEPTACLES 6,120 1.0/.5 EXISTING 22,500 1.00 AMPS 89 MOTORS 1.00 LARGE MOTOR 1.25 TOTAL DEMAND TOTAL PNLBD - VA 30,924 SUPP HEAT 1.00 SHOW WINDOW 1.25 30,924 VA AMPS 86 MISC EQUIP 2,304 1.00 LTG TRACK 1.00 86 A PANELBOARD NOTES C# - VIA LTG CONTACTOR # HT# - PROVIDE HANDLE -TIE FOR MULTI -WIRE BRANCH CIRCUIT ** - ALL CIRCUIT BREAKERS ARE EXISTING TO REMAIN U.N.O. LTG TRACK - TRACK LENGTH * ** - NEW CIRCUIT BREAKER SIGN /DISPLAY - ' SIGNAGE & DISPLAY CASE HT7 HT7 HT7 HT8 HT8 HT8 HT9 HT9 HT9 HT1 0 HT10 HT10 HT1 1 HT1 1 * * * /HT1 1 ***/HT1 2 HT1 2 HT12 HT1 3 HT1 3 HT13 PANEL SCHEDULES SCALE: NONE VERIFY EXISTING PANELBOARD AIC RATINGS AND COMPARE TO CALCULATED FAULT CURRENT VALUES. REPORT FINDINGS TO ENGINEER FOR EVALUATION. TYPICAL FOR ALL EXISTING PANELBOARDS. AIC RATING FOR NEW CIRCUIT BREAKERS INSTALLED WITHIN EXISTING PANELBOARDS MUST EXCEED LARGER OF EXISTING PANELBOARD AIC RATING OR CALCULATED FAULT CURRENT VALUE. TYPICAL FOR NEW CIRCUIT BREAKERS INSTALLED IN EXISTING PANELBOARDS. D A REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC APR 1 9 2012 Tukwila. DING DIVISION RECEIVED APR 13 2012 PERMIT CEN 1HENDERSON ENGINEERS= 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hel- eng.com 1250000367 WA. CORPORATE NUMBER:1754 EXPIRES 06/30/12 Office Depot Approval Stamp Architecture Partners Architectural Design Group, Inc. 16398 NE 85TH ST. SUITE 101 Redmond, WA 98052 Telephone 425 636 -8006 www.padgi.com MEP Henderson Engineers, Inc. 8325 Lenexa Drive Lenexa, KS 66214 Telephone 913.742.5000 Fax 913.742.5001 www.hei- eng.com Revisions / Issues REV DATE DESCRIPTION 3.6.12 BLDG. PERMIT SUBMITTAL 4.2.12 SCOPE REDUCTION Office DEPOT Wit" Care ofkkam rr BUY GREEN SELL GREEN BE GREEN 2010 PROTOTYPE OD STORE #XXXX 6600 North Military Trail N278 Boca Raton, FL 33496 TEL: 561/438 -6299 FAX: 561/438 -7237 Seal Project Title Office Dept #0984 300 Andover Park W #400 Tukwila, WA 98188 Gross Tenant Area: 22,199 sq. ft. Job Number Drawing PANEL SCHEDULES Scale AS NOTED ON DRAWING Drawing Date 3.6.12 F► PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THESE DRAWINGS. PANEL SCHEDULE GENERAL NOTES SCALE: NONE NOTE: EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS- BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. z Short- Circuit and Voltage Drop Calculations v2.09.02 Distances are for calculation purposes only and shall not be used for contractor takeoffs nor bidding - Contractor shall notify Engineer of any field condition that results Ina change of 10% or greater circuit distance The following calculations are based on the "Point -by- Point" method where: ISC (2) = ISC(1) x M(1) i= 1/(1 +f) Feede - (30) 1.732 x L x Isc XFMR: f (30) = IP(sca)x Vp x 1.73 x %Z IS(sca)= Vp x M x IP(sca) VOLTAGE DROP (30): ISC (1) = short circuit current at fault point 1 C x E 100,000 x KVA Vs %VD= ((R x cos(arccos(pf)) + X x sin (arccos(pf))) x L/# x I x 1.73) / E ISC (2) = short circuit current at fault point 2 Feeder/ (10)= 2 x L x Isc XFMR: f (10)= IP(sca)x Vp x XZ VOLTAGE DROP (10): C x E 100,000 x KVA %VD= ((R x cos(arccos(pf)) + X x sin(arccos(pf))) x 2 x L/# x I) / E L = Length of circuit E = Line to line volts IP Primary short circuit current %VD CUM= Cumulative Voltage Drop from Fault Point 1 to Fault Point # C = "C Factor from Sussman table where "C = 1 / impedance per linear foot Vp Primary voltage R= resistance in ohms per LF Feeder Types = IS= Secondary short circuit current X= reactances in ohms per LF NM - Non Magnetic Conduit, M - Magnetic Conduit, FB - Feeder Busway, PB - Plug -in Busway, TX Transformer Vs= Secondary voltage Fault Source Source Feeder L -L Circuit Load Circuit Conductor Conductor Transformer FAULT VOLTAGE TOTAL Fault Point Bus /Feeder Phase (Fault Isc Conduit Material Conductor Busway Volts Length Power Load Resistance Reactance Impedence, Degree CURRENT DROP V.D. Point (F #) Description Point) (amps) Type CU or AL # Wire /Bus Size 'C' value C value E L Factor(pf) A R X Z/ 0 Type kVA Rise Z V sec f M Isc %VD %VD CUM (F #) 1 Utility Service Point 17200 at the secondary of the utility transformer 480Y/277V 3 phase Source Isc + 6X Motor Contribution = 18280 1 Motor Contribution 180 The connected full load motor amps (includes compressors) on the system 2 To Landlord Distribution 3 18280 18280 NM CU 4 Set(s) of 350 kcmil 22737 480 30 0.9 960 0.000038 0.000040 0.451027 0.022 0.98 17891 0.13% 0.13% 2 3 To MDP 3 2 17891 M. CU 2 Set(s) of 350 kcmil 19704 480 200 0.9 480 0.000039 0.000050 0.451027 0.328 0.75 13476 0.99% 1.12% 3 4 To LA 3 3 13476 M CU 1 Set(s) of 1/0 AWG 8925 480 5 0.9 100 0.000120 0.000055 0.451027 0.027 0.97 13118 0.02% 1.14% 4 5 To C 3 3 13476 M CU 2 Set(s) of 250 kcmil 16483 480 8 0.9 320 0.000054 0.000052 0.451027 0.012 0.99 13318 0.03% 1.15% 5 6 To TX1 3 3 13476 M CU 1 Set(s) of 2 AWG 5907 480 10 0.9 120 0.000200 0.000057 0.451027 0.082 0.92 12451 0.09% 1.21% 6 7 TX1 3 6 12451 TX 480 Ext'g 1 12.5 150 4.43 208 4.076 0.20 5660 1.21% 7 8 To PB 3 7 5660 M CU 1 Set(s) of 4/0 AWG 15082 208 5 0.9 240 0.000063. 0.000051 0.451027 0.016 0.98 5573 0.08% 1.29% 8 9 To TX2 3 5 13318 M CU 1 Set(s) of 1/0 AWG 8925 480 210 0.9 72 0.000120 0.000055 0.451027 1.131 0.47 6250 0.72% 1.87% 9 10 TX2 3 9 6250 TX CU 480 Ext'g 75 150 5.7 208 3.949 0.20 2914 1.87% 10 11 To PD 3 10 2914 M CU 1 Set(s) of 4/0 AWG 15082 208 10 0.9 180 0.000063 0.000051 0.451027 0.016 0.98 2868 0.12% 1.99% 11 CONFIRM THIS IS POINT OF SERVICE ENTRANCE AND THAT NEUTRAL AND SERVICE GROUND SYSTEM ARE BONDED TOGETHER AND TO THE AVAILABLE GROUNDING ELECTRODES IN ACCORDANCE WITH NEC, STATE, AND LOCAL CODES.-� ELECTRICAL SINGLE LINE DIAGRAM LEGEND INDICATES EQUIPMENT TO BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. INDICATES EXISTING EQUIPMENT. 1 UTILITY TRANSFORMER 480Y/277V, 30, 4W SEC EXISTING 17,200AFC (F1) LA \DLORD SWITCHBOARD _#2 (EXISTING) 1200 AMPS 480Y/277V 30 4W 17,891 FCA 0.13 %CVD 30 FEET (F2) MBJ f MBJ TO GROUND BAR AT MAIN TELEPHONE BOARD (TTB) s- TO STRUCTURAL STEEL TO ABOVE GROUND METAL PIPING 5- TO WATER SERVICE s- NEUTRAL BUS GROUND BUS UTILITY METER ETR 600A 3P 600AF ETR T V3P TO GROUND ROD(S) I 400A 3P 400AF ETR TO ADJACENT TENANT LEASE SPACE 600 AMPS _480Y/277V 30 4W EXISTING) 13,476 FCA 1.12 %CVD 200 FEET (F3) 125A 3P ETR C150A 3P ETR CONTACTOR SCHEDULE CONTACTOR FUNCTION CIRCUIT CONTROLLED (VIA CONTACTOR POLE INDICATED) LOAD DESCRIPTION LC1 SALES LIGHTS PARTIAL 1 _ LA #2 LA #5 LA #6 LA #9 LA #10 LA #13 LA #14 LA #18 - - - 50% OF SALES FLOOR LIGHTING LC1A EMPLOYEE LIGHTS LA #1 LA #18 LA #22 LA #24 LA #26 LA #28 LA #30 - 1.04 125% EMPLOYEE LIGHTS LC1B CUSTOMER LIGHTS PB #19 PB #21 - - EXISTING LOAD TO BE DELETED 54.85 100% 54.85 TOTAL LOAD IN -RACK LIGHTS LC2 SALES LIGHTS PARTIAL 2 LA #3 LA #4 LA #7 LA #8 LA #11 LA #12 LA #15 LA #16 LA #21 - - - 50% OF SALES FLOOR LIGHTING LC2A EMPLOYEE LIGHTS LA #20 LA #32 AMPS 428 EMPLOYEE LIGHTS LC3 CANOPY LIGHTS NOT USED LC4 SECURITY LIGHTS NOT USED LC5 BUILDING SIGNS PD #23 PD #25 PD #27 PD #29 PD #40 - ter" BUILDING SIGNS /� ► / ► ■ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - / _ NOTE: 1. FIELD VERIFY EXISTING CONTACTORS AND NUMBER OF POLES AVAILABLE. PROVIDE NEW CONTACTORS AND RELAYS AS REQUIRED TO MEET DESIGN INTENT. COORDINATE RE- PROGRAMMING OF EMS WITH OFFICE DEPOT CONSTRUCTION MANAGER AND EMS VENDOR. PROVIDE ALL NECESSARY LABOR AND MATERIALS FOR A FULLY OPERATIONAL SYSTEM. ri H ENDERSON /ENGINEERSI 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hei-eng.eem 1250000367 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/12 Office Depot Approval Stamp Architecture Partners Architectural Design Group, Inc. 16398 NE 85TH ST. SUITE 101 Redmond, WA 98052 Telephone 425 636 -8006 www.padgi.com MEP Henderson Engineers, Inc. 8325 Lenexa Drive Lenexa, KS 66214 Telephone 913.742.5000 Fax 913.742.5001 www.hei- eng.com Revisions / Issues REV DATE DESCRIPTION 3.6.12 BLDG. PERMIT SUBMITTAL 4.2.12 SCOPE REDUCTION 2 CONTACTOR SCHEDULE NO SCALE C400A 3P ETR NEUTRAL BUS MBJ MBJ J GROUND BUS FEEDER SCHEDULE 13,118 FCA 1.14 %CVD 5 FEET (F4) SPD ETR MBJ EXISTING TO REMAIN GND, #2 COPPER GROUND, 3/4" C EXISTING MAIN BONDING JUMPER EXISTING PNLBD LA 480/277V 12,451 FCA 1.21 %CVD 5 FEET (F6) r ,T -1 ��' 1 12.5KVA 1480V 30, 3W PRIMARY Lr; -212(2 _12087120V 30, 4W SEC 5,660 FCA 1.21 %CVD (F7) 13,318 FCA 1.15 %CVD 8 FEET (F5) 225A, (4) #4/0, (1) #2G, (1) #4 10, 2 -1/2" C ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATION AND COPPER CONDUCTORS WITH TYPE THHN /THWN -2 INSULATION; FOR ALUMINUM CONDUCTORS AND FOR TERMINATION OR INSULATION TYPES RATED LESS THAN 75 DEG C, MODIFY SIZES ACCORDING TO NFPA 70. NOTE: UTILITY TRANSFORMER: 300 KVA, 2.1%Z, SECONDARY 480Y/277V, AVAILABLE FAULT CURRENT AT SECONDARY 17,200A UTILITY COMPANY: PUGET SOUND ENERGY UTILITY CONTACT: CUSTOMER SERVICE, (888) FAULT CURRENT SOURCE: WEBSITE CHART THE AVAILABLE FAULT CURRENT IS AVAILABLE ON VALUE OBTAINED FROM THE WEBSITE FILE DATED PAD MOUNT IS: 321- 7779, CONTACTED ON 2 /28/2012 THE COMPANY'S WEBSITE. THE JUNE 2011 IS 17,200A. 5,573 FCA 1.29 %CVD 5 FEET (F8) EXISTING PNLBD PB1 208/120V EXISTING PNLBD PB2 208/120V ETR EXISTING PNLBD C 480/277V SUPPORT SYSTEM SHALL BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER INSTALL TRANSFORMER ABOVE AND IN FRONT OF ELECTRICAL PANELBOARD MINIMUM DISTANCE 5' -0" PANELBOARD WORKING SPACE CLEARANCE AS REQUIRED BY NEC LIB -09-1'I CONDUCTOR SIZE HAS BEEN INCREASED FOR VOLTAGE DROP. x 6,250 FCA 1.87 %CVD 210 FEET (F9) -1T -2 1��'75KVA nern 148OV 30, 3W PRIMARY __j208/120V 30, 4W SEC RELOCATED (SUSPENDED) 2,914 FCA 1.87 %CVD (F10) /-- DEDICATED ELECTRICAL SPACE. EXTENDS ITO 6' ABOVE PANEL BOARD OR TO STRUCTURAL CEILING, WHICHEVER IS LOWER. LOCATE TRANSFORMER 6" MINIMUM FROM ALL WALLS. MAXIMUM OF 10' SECONDARY CONDUCTOR LENGTH. FLEXIBLE CONDUIT RIGID CONDUIT ELECTRICAL PANELBOARD SUPPLIED BY TRANSFORMER DEDICATED ELECTRICAL SPACE (BOTTOM OF PANELBOARD TO FLOOR) FLOOR elSUSPENDED TRANSFORMER MOUNTING LOCATION DETAIL NO SCALE 2,868 FCA 1.99 %CVD 10 FEET (F11) RELOCATED PNLBD PD 208/120V TENANT ELECTRICAL SERVICE LOAD SUMMARY TENANT OCCUPANCY TYPE: TENANT SQUARE FOOTAGE: M 22,239 SERVICE DESCRIPTION: 480Y/277V, 3PH LOAD DESCRIPTION Connected KVA Demand FACTOR Demand KVA EXISTING PEAK UTILITY LOAD © 0.9 pf N/A 125% 179.17 HVAC - SUMMER 0.00 100% 0.00 HVAC - WINTER 0.00 100% 0.00 LIGHTING (PER NEC -220) 1.04 125% 1.30 RECEPTACLES 19.98 100 %;50% 14.99 EXISTING LOAD TO BE DELETED 54.85 100% 54.85 TOTAL LOAD -31.53 KVA 142.91 TOTAL AAPACITY -37.92 AMPS 171.89 SERVICE AMPACITY 600 AMPS 600.00 SPARE CAPACITY AMPS 428 *PER UTILITY COMPANY BILLING PEAK DEMAND OF: 129 KW Mar -11 TENANT ELECTRICAL LOADS ARE BEING REDUCED PER REDUCTION IN SQUARE FOOTAGE, REMOVAL OF HVAC UNITS, AND REDUCED LIGHTING LOADS. SINGLE LINE DIAGRAM - POWER NO SCALE VIEWF_CDE WITH NFPA 70 -NBC APR 1 9 2012 --.6% .Tukwila BUILDING DIVISION RECEIVED APR 13 2012 PERMIT CENT Office DEPOT r�ngCate o,; ,,ers BUY GREEN SELL GREEN BE GREEN 2010 PROTOTYPE OD STORE #XXXX 6600 North Military Trail N278 Boca Raton, FL 33496 TEL: 5611438 -6299 FAX: 561/438-7237 Seal Project Title Office Dept #0984 300 Andover Park. W #400 Tukwila, WA 98188. Gross Tenant Area: 22,199 sq. ft. Job Number Drawing SINGLE LINE DIAGRAMS AND CONTACTOR SCHEDULE Scale AS NOTED ON DRAWING Drawing Date 3.6.12 �► PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THESE DRAWINGS. NOTE: EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS- BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS.