Loading...
HomeMy WebLinkAboutPermit EL12-0327 - CORELINKCOREUNK 3311 S 120 PL EL1 2-0327 Parcel No.: Address: City olkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov 1023049069 3311 S 120 PL TUKW Project Name: CORELINK ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL12 -0327 04/27/2012 10/24/2012 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: SABEY CORPORATION 12201 TUICWILA INTL BLVD 4THFL , SEATTLE WA JASON PECOTTE Phone: 206 - 633 -2811 900 N 34 ST, SUITE 108 , SEATTLE WA TITAN ELECTRIC INC Phone: 206 - 633 -2811 900 N 34 ST, SUITE 108 , SEATTLE WA Contractor License No: TITANEI963OB Expiration Date: 09/02/2012 DESCRIPTION OF WORK: INSTALL (2) 500 KW UPS AND DISTRIBUTION SWITCHGEAR Value of Electrical: NRES: $300,000.00 RES: $0.00 Fees Collected: $4,898.00 Type of Fire Protection: UNKNOWN National Electrical Code Edition: 2008 Electrical service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: (4)- Date: Lt—):7 v 1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does = p> . e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performan• - am authorized to sign and obtain this electrical permit. �j l Signature: Date: ( 7` Print Name: /-ek This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL12 -0327 Printed: 04 -27 -2012 • • PERMIT CONDITIONS Permit No. EL12 -0327 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -0327 Printed: 04 -27 -2012 CITY OF TUKWI `` Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov • Electrical Permit No. '"":1---1 )— 0 ?.)-7 Project No. Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 3311 S 120th Place, Tukwila WA 98168 Suite Number: 120 Floor: Main Core Link Tenant Name: PROPERTY OWNER Name: Jason Pecotte Address: 900 N 34th St, Suite 108 Name: Phone: (206) 633 -2811 Fax: (206) 374 -2128 Email: jasonp@titanelectric.net Address: Phone: (206) 622 -2811 Fax: (206) 374 -2128 City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Jason Pecotte Address: 900 N 34th St, Suite 108 City: Seattle State: WA Zip: 98103 Phone: (206) 633 -2811 Fax: (206) 374 -2128 Email: jasonp@titanelectric.net New Tenant: ❑ Yes m .. No . ELECTRICAL CONTRACTOR INFORMATION Company Name: Titan Electric Address: 900 N 34th St, Suite 108 City: Seattle State: WA Zip: 98103 Phone: (206) 622 -2811 Fax: (206) 374 -2128 Contr Reg No.: TitanE1963OB Exp Date: 09/02/2012 Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 300,000 Scope of Work (please provide detailed information): Install (2) 500 KW UPS and Distribution Switchgear. Will service be altered? ❑ Yes gi No Adding more than 50 amps? t] Yes ❑ No Type of Use: Commercial Type of work: ID New m Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy 0 Seattle City Light H:\Applicatious\Forms- Applications On Line12011 App licatiorelElectrical Pe®it Application Revised 8- 9- 11.docs Revised: Angust 2011 bh ❑ Remodel ❑ Telecommunication ❑ Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outhuildings ❑ Low voltage systems (alarm, furnace thermostat) $152.85 $81.90 ea $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added /altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added /altered without service change $54.60 (up to 5 circuits) ❑ Circuits added /altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL C �t . i; ►1: Signature: Print Name: Mailing Address: ,11/4?- Xrco77-0,- 900 N 34th St, Suite 108 H: Applications\Forms- Applications Oa Ime'2011 Applicetiom\Electical Permit Application Revised 8-9-11 Aocx Revised: August 2011 bh Day Telephone: Seattle City Date: (206) 3 -2811 WA 98103 State Zip Page 2 of 2 • • C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1023049069 Address: 3311 S 120 PL TUKW Suite No: Applicant: CORELINK RECEIPT Permit Number: EL12 -0327 Status: APPROVED Applied Date: 04/06/2012 Issue Date: Receipt No.: R12 -01445 Payment Amount: $3,918.40 Initials: WER Payment Date: 04/27/2012 09:56 AM User ID: 1655 Balance: $0.00 Payee: TITAN ELECTRIC INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 13177 3,918.40 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 3,918.40 Total: $3,918.40 doc: Receiot -06 Printed: 04 -27 -2012 • • �J��rI�A wqs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1023049069 Address: 3311 S 120 PL TUKW Suite No: Applicant: CORELINK RECEIPT Permit Number: EL12 -0327 Status: PENDING Applied Date: 04/06/2012 Issue Date: Receipt No.: R12 -01262 Payment Amount: $979.60 Initials: WER Payment Date: 04/06/2012 03:00 PM User ID: 1655 Balance: $3,918.40 Payee: TITAN ELECTRIC INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 13032 979.60 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 979.60 Total: $979.60 doc: Receiot -06 Printed: 04 -06 -2012 INSPECTION'RECORD �u2 o3Z7 ✓' Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter'Blvd., #100, Tukwila. WA 98188 ` (206) 431 -3670 PermitTnspection Request Line (206) 431 -2451 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: r% 4-jAhlt.V Inspector • - Date: f/0 7 /, 3 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Project:.„j !� Type of Inspection: 21 00 Address: ,1 Pt- , _ss J .:! L-1 1.. Date Called: Special Instructions: 0\„ 14.-.... . .v� ( ' kko Date Wanted:. /1)7 (ap m. Requester: t Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: r% 4-jAhlt.V Inspector • - Date: f/0 7 /, 3 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. • PERMIT NO.l CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3.670 Permit Inspection Request Line (206) 431 -2451 Project: C'z' lkvisi Type of Inspection: Address: 551 I S T /Z.0 5 1.- Date Called: II Special Instructions: • Date Wanted:. tU �_as o, CPS Requester: Phone No: JApproved per applicable codes. COMMENTS: Corrections required prior to approval. '. 1 f .�J ctu,Cf7) Inspector: n REINSPECTION IFEE REQUIRED. Prior to next inspection; fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule;reinspection. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 .-Z. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: 60 Je- n/ Type of Inspection: 7.,rei � �(� 7001, Address: 3311 s.. Date Called: .—, Special Instructions: Date Wanted:. r®r j J am. P- • Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: r 6I d-,� C J� }� r a i 91 c)Nicx04 -5 , % V l' I NIA -`1 J!V S 1 f, bt1CS S T) ?? 1 Date: f o v /fa._ n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING D IVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 =367 Permit Inspection Request Line (206) 431 -2451 Project: (01241,4644. Type of Inspection: r . 7 .-1 - Address: 331 I 5. 1 ` Date Called: Special Instructions: f� Date Wanted:. f : rr, P.m. Requester: ■ Phone No: 0 Approved per applicable codes. Ei Corrections required prior to approval: COMMENTS: -- .P614064'6 ArsiD rirrAMI4A11045 DP i gP GI A-41); tl ?s 1)15+ C-L 01)5 fit:. Inspector: rr n REINSPECTION FEE REQUIRED. Prior to next inspection: fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection:. INSPECTION_ RECORD Retain a copy with permit jil -o3Z7 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 \R (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: (1,64.61,04.. Type of Inspection: 7003 In . Address: `� I C . /2a /1-- fJ Date Called: =� Special Instructions: Date Wanted: . .�y it r f a.m. P.m. Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ?A/ ( VkzGkets5 _ 1 = 1461 Date:D7 %0 pli 1 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 y (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: / Q QV.-- Type of Inspection: 003 Address. 3311 5 . a. Date Called: /E%E47 tAist, rcpt. Special Instructions: • Date Wanted: . D 51 arr p.m. Requester: Phone No: Ij(J Approved per applicable codes. aCorrections required prior to approval. COMMENTS, J� 4 614124441a5 a 41 ,' /E%E47 tAist, rcpt. C • Inspector: Date: es—. A 3 f2, ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. *two cuwWc€Py PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0327 PROJECT NAME: CORELINK SITE ADDRESS: 3311 S 120 PL X Original Plan Submittal Response to Correction Letter # DATE: 04 -06 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS. B�lilding ivision Fire Prevention Public Works n Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 04 -10-12 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route X Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05-08-12 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 Contractors or Tradespeople Pri .ter Friendly Page Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name TITAN ELECTRIC INC UBI No. 602250925 Phone 2066332811 Status Active Address 900 N 34Th Ste 108 License No. TITANEI9630B Suite /Apt. License Type Electrical Contractor City Seattle Effective Date 9/2/2004 State WA Expiration Date 9/2/2012 Zip 98103 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TITANE *986Q5 TITAN ELECTRIC Electrical Contractor General Unused 11/25/2002 11/25/2004 Archived Electrical Administrator INFORMATION License CROOKT *011 PB Name CROOK, TRAVIS Status Active Business Owner Information Name Role Effective Date Expiration Date FUNG, LAWRENCE H Agent 09/02/2004 Bond Amount BURKE, PATRICK D President 09/02/2004 9808431 FUNG, LAWRENCE H Secretary 09/02/2004 ELECTRICAL CITATION CROOK, TRAVIS J Vice President 09/02/2004 COLONIAL AM CAS & SURETY OF MD Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Lexon Ins Co 9808431 08/03/2011 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.00 08/08/2011 1 COLONIAL AM CAS & SURETY OF MD LPM4066933 08/03/2004 Until Cancelled 08/03/2011 $4,000.0008/10/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EREEB00416 8/10/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 ECHAE00321 8/25/2008 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EREEB00206 2/20/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /Ini /bbip /Print.aspx 04/27/2012 Contractors or Tradespeople Pester Friendly Page • IEOXFJ00469 17/29/2010 119.28.101 RCW 'ELECTRICAL CITATION 'Satisfied 1 $2,000.001 Page 2 of 2 https: // fortress .wa.gov /lni /bbip /Print.aspx 04/27/2012 Apr 03, 2012, 8 :• 48am — Core /ink Seatt /e 111E7 al Engineering Design G WIRING DEVICES IQJ WALL MOUNTED J -BOX NON -FUSED DISGONNEGT SWITCH al FUSED DISCONNECT SWITCH ■ MAGNETIC CONTROLLER (STARTER) COMBINATION STARTER/DISCONNECT SWITGH $r THERMAL OVERLOAD SWITCH +iP MOTOR. k- NORMALLY CLOSED GONTAGT -1 1-- NORMALLY OPEN CONTACT DISTRIBUTION AND RACEWAY 3 MAIN DISTRIBUTION CENTER (MDG) SURFACE MTD PANELBOARD RECESSED PANELBOARD TRANSFORMER BRANCH GIRGUIT HOMERUN CONDUIT GONGEALED IN FLOOR OR UNDERGROUND CONDUIT EXPOSED OR CONGEALED IN WALL OR GEILINS o RAGEWAY UP • RACEWAY 170WN 1 3 GAPPED CONDUIT CURRENT TRANSFORMER GIRGUIT BREAKER SWITGH FUSED SWITCH 1 I I-- GROUND METER ABBREVIATIONS AND SYMBOLS EG GGT N IG GFI >l AG AFF UON EM GP E1NG EF (E) (ER) (R) (RI) 04) GT MDF IDF TTB 3 ELECTRICAL CONTRACTOR GIRGUIT NEUTRAL GROUND ISOLATED GROUND GROUND FAULT INTERRUPTOR WEATHER PROOF ABOVE COUNTER - VERIFY HEIGHT ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED EMERGENCY CHILDPROOF ELECTRICAL WATER COOLER EXHAUST FAN EXISTING TO REMAIN EXISTING TO BE RELOGATED EXISTING TO BE REMOVED RELOGATED LOGATION NEW DEVICE CURRENT TRANSFORMER MAIN DISTRIBUTION FACILITY INTERMEDIATE DISTRIBUTION FACILITY TELEPHONE TERMINAL BOARD POOL EQUIPMENT SCHEDULE NOTATION KITCHEN EQUIPMENT SCHEDULE NOTATION MEGHANIGAL EQUIPMENT SGHEDULE NOTATION DETAIL NOTE DELTA REVISION NOTE ELEGTRIGAL WIRE SIZE SEPARATE PERMIT REQUIRED FOR e Me chanical pectricsi tia-Plumbing 0.1eis NOV City of Tukwila r. 91'LD G AIVISiON j L REVISIONS No changes shall be made to the scope r m( without prior approval of ukwila Building Division. i 'TrZ: sons will require a new plan submittal and may include additional plan review fees. ELECTRICAL SPECIFICATION AND GENERAL NOTES THE GONTRAGTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM. MATERIALS AND INSTALLATION SHALL COMPLY WITH GODES, LAWS AND ORDINANCES OF FEDERAL, STATE AND LOCAL GOVERNING BODIES HAVING JURISDICTION. MATERIALS AND EQUIPMENT SHALL BE LISTED AND /OR LABELED BY U.L., ETL, GSA OR ANOTHER RECOGNIZED TESTING LAB. THE GONTRAGTOR SHALL SECURE AND PAY FOR ALL PERMITS, GOVERNMENTAL FEES, TAXES AND LICENSES NECESSARY FOR THE PROPER EXEGUTION AND GOMPLETION OF THE ELECTRICAL WORK. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO GOVERNMENTAL AGENCIES AND UTILITY COMPANIES SHOP DRAWINGS, WHICH ARE REQUIRED BY THESE AGENGIES, FOR THEIR APPROVAL. THE CONTRACTOR SHALL NOTIFY THE ENGINEER/OIAINER OF ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN VIOLATION OF LAWS, ORDINANCES, RULES OR REGULATIONS OF AUTHORITIES HAVING JURISDICTION. THE GONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE 51TE, AND THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS AND LOCAL GONDITIONS RELATING TO THE WORK. FAILURE TO DO 50 WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE GONTRAGT. ALL MATERIALS, AND EQUIPMENT SHALL BE ERECTED, INSTALLED, GONNEGTED, GLEANED, ADJUSTED, TESTED, CONDITIONED, AND PLACED IN SERVICE IN AGGORDANGE WITH THE MANUFACTURER'S DIRECTIONS AND RECOMMENDATIONS. ALL GUTTING, DRILLING AND PATGHING OF MASONRY, STEEL OR IRON WORK BELONGING TO THE BUILDING MUST BE DONE BY THIS GONTRAGTOR IN ORDER THAT HIS WORK MAY BE PROPERLY INSTALLED, BUT UNDER NO GONDITIONS MAY STRUCTURAL WORK BE GUT, EXCEPT AT THE DIREGTION OF THE ARCHITECT- DESIGNER OR THEIR REPRESENTATIVE. 10. SHOP DRAWINGS SHALL INCLUDE MANUFACTURER'S NAMES, CATALOG NUMBERS, GUTS, DIAGRAMS AND OTHER SUGH DESCRIPTIVE DATA AS MAY BE REQUIRED TO IDENTIFY AND REVIEW THE EQUIPMENT. SUBMITTALS SHALL BE IN LOGICAL GROUPS, FOR EXAMPLE, ALL LIGHTING FIXTURES, PARTIAL SUBMITTALS WILL NOT BE REVIEWED. II. SUBMIT DIGITAL COPIES OF THE FOLLOWING SHOP DRAWINGS FOR REVIEW. A. PANELBOARDS B. DISCONNECTS G. PROVIDE "AS- BUILT" DRAWINGS AND SUBMIT TO OWNER/ENGINEER. D. UPS E. BATTERIES 12. ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW, UNLESS SPEGIFIGALLY INDICATED AS EXISTING TO BE REUSED. 13. EXCEPT AS NOTED OTHERWISE, ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN ON DRAWINGS INCLUDING LABOR, EQUIPMENT AND MATERIALS SHALL BE IN STRICT GOMPLIANCE WITH THE BUILDING STANDARDS. 14. PROVIDE COMPLETE METAL RACEWAY SYSTEMS AND ENGLOSURES FOR ALL WIRING THROUGHOUT THE EXTENT OF THE REQUIRED SYSTEM. 15. ELECTRICAL METALLIC TUBING (EMT) SHALL BE USED FOR ALL WALL OUTLETS 4 TELEPHONE OUTLETS RUNNING IN PARTITIONS, BELOW RAISED FLOOR OR ABOVE CEILINGS. EMT FITTINGS SHALL BE OF THE STEEL COMPRESSION TYPE OR STEEL SET SGREW FITTINGS. 16. MINIMUM CONDUIT SIZE SHALL BE 3/4" UNLESS OTHERWISE INDICATED. 11. WIRE NO. 8 AND SMALLER FOR USE IN INTERIOR DRY LOCATIONS SHALL BE TYPE THWN/THNN THERMOPLASTIC 600 VOLT INSULATED GOPPER CONDUCTORS. FEEDERS AND POWER WIRING NO. 6 OR LARGER SHALL BE TYPE THWN 600 VOLT INSULATED COPPER. WIRE HIGH 15 INSTALLED IN RACEWAYS IN MOIST OR DAMP LOCATIONS SHALL BE TYPE XHHW, 600 VOLT INSULATED COPPER CONDUCTORS. NO WIRE SMALLER THAN NO 12 MG SHALL BE USED FOR LIGHTING OR POWER WIRING. WIRE NO. 10 AND SMALLER MAY BE SOLID OR STRANDED, WIRE NO. 8 AND LARGER SHALL BE STRANDED. I8. ALL NEV :CIRCUITS SHALL HAVE A GROUND WIRE INSTALLED. 11. ALL - WIRING' NOT INSTALLED IN GONDUIT AND INSTALLED IN THE GEILING SPACE SHALL BE PLENUM RATED. 20. ALL NEW GIRGUIT BREAKERS FOR NEW OR EXISTING PANELBOARDS SHALL MATGH EXISTING BUILDING PANELBOARD MANUFACTURER AND BREAKER TYPE. THE CONTRACTOR SHALL PROVIDE NEW TYPE WRITTEN PANEL DIRECTORIES' FOR ALL NEW PANELS AND EXISTING PANELS WHICH HAVE CHANGED. 21. ELEGTRIGAL GONTRAGTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT -MAY BE REQUIRED TO ENCLOSE RECEPTACLES. 22. IN SUSPENDED CEILINGS, SUPPORT CONDUIT AND JUNCTION BOXES DIREGT FROM THE STRUCTURAL SLAB, DECK, OR FRAMING PROVIDED FOR THAT PURPOSE. 23. SHOULD ACTUAL FIELD GONDITIONS REQUIRE INDICATED GIRGUIT DESIGNATIONS TO VARY, INDICATE THE GIRGUIT NUMBER USED ON THE "AS- BUILT" DRAWINGS. 24. G.G. SHALL INCLUDE IN HIS COST THE REMOVAL OF ALL EXISTING ELECTRICAL DEVICES, CONDUITS, FIXTURES AND EQUIPMENT. DISCARD ALL EQUIPMENT AS REQUIRED. E.G. SHALL BE RESPONSIBLE FOR DISCONNECTING PRIMARY SERVICE AND TEMPORARY POWER. 25. ALL EXISTING ELEGTRIGAL SERVICES NOT SPEGIFICALLY INDICATED TO BE REMOVED OR ALTERED SHALL REMAIN AS THEY PRESENTLY EXIST. 26. ALL EXTERIOR CONDUIT SHALL BE RIGID GALVANIZED STEEL (RCS). FILE COPY Permit No., L-1 ?- 0-7 phr r 'Aew approval is subject to errors and omlssions. 11 of construction documents does not aut or!o of any adopted code or ordinance. Receipt oa approved Field + = acknowledged: By Date: City OfTtdcwila BUILDING DIVISION REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC APR 19 2012 City of Tukxnla` —'— BUILDING DIVISION c48ftiA APR 1'22011 PERMIT CENTER :nN N X E in 0�C 0�" 3 Ln 'D• D O Oc Pi el Ot cu 17: • U N N m in 00 y > m Cd • a, 0 0 rn z 2 W W W J L) w 2 Li 0 0 Z w ce W Z w u 0 z W ce U z 0 M DESCRIPTION w ce CO 0 w Z 0 Z CO w CHECKED BY: N 0 N m O O ISSUE DATE: Copyright © 2009 - A 1 rights reserved Architectural Engineering Design Group, Inc. All design drawings and written material herein may not be used or duplicated without the written consent of Architectural Engineering Design Group, Inc. SHEET NO.: EO.O PANEL 'HMI' VOLTAGE L -L: 480 VOLTAGE L -G: 211 TYPE: 3PH /41,1 MOUNTING: SURFACE NOTES: LOGATION: MEGH/ELEC. 114 BUS RATING: 600 AMP MAIN GB: M.L.O. 5.G. RATING: 65K AIG FULLY RATED FED FROM: PANEL DPI CI R. NO GGT TYPE LOAD VA LOAD DESCRIPTION GIRGUIT BRKR BUS CIRCUIT BRKR LOAD DESCRIPTION LOAD VA OCT TYPE CI NO POLE TRIP TRIP POLE I LM 21616 FUTURE CRAG 3 100 A 20 3 FUTURE MECHANICAL 1000 M 2 3 LM 21616 -- -- -- B -- -- -- 1000 M 4 5 LM 21616 -- -- -- G -- -- 1000 M 6 1 M 21616 FUTURE GRAG 3 100 A 20 3 FUTURE MEGHANIGAL 1000 M 8 1 M 21616 -- -- -- B -- -- -- 1000 M 10 I1 13 15__ 17 11 M 21616 21616 -- -- -- 100 A---- -- -- -- 1000 M 12 M M M M FUTURE CRAG 3 20 3 FUTURE MECHANICAL 1000 M 14 21616 21616 21616 -- -- -- B -- -- -- 1000 M 16 -- FUTURE GRAG 3 -- 100 G A -- 25 -- -- 1000 M 18 3 FUTURE MECHANICAL 2000 M 20 21 M 21616 -- -- -- B -- -- -- 2000 M 22 23 M 21616 -- _ -- -- G - - -- -- 2000 M 24 25 M 21616 FUTURE GRAG 3 100 A 25 3 FUTURE MEGHANIGAL 2000 M 26 _ 21 M 21616 -- -- -- B -- -- -- 2000 M 28 21 M 21616 -- -- -- G -- -- -- 2000 M 30 31 M 0 FUTURE GRAG REDUNDANT 3 100 A 25 3 FUTURE MECHANICAL 2000 M 32 33 M 0 -- -- -- g -- -- -- 2000 M 34 35 M 0 -- -- -- G -- -- -- 2000 M 36 31 M 0 FUTURE GRAC REDUNDANT 3 100 A 30 3 FUTURE MECHANICAL 3000 M 38 3q M 0 -- -- -- B -- -- -- 3000 M 40 41 M 0 -- -- -- G -- -- -- 3000 M 42 43 SPARE 1 20 A 30 3 FUTURE MECHANICAL 3000 M 44 45 SPARE 1 20 B -- -- -- 3000 M 46 41 SPARE 1 20 G -- -- -- 3000 M 48 4q SPARE 1 20 A 30 3 FUTURE MECHANICAL 3000 M 50 51 SPARE 1 20 B -- -- -- 3000 M 52 53 SPARE 1 20 C -- -- -- 3000 M 54 55 SPARE 1 20 A 20 I SPARE 56 51 SPARE 1 20 B 20 I SPARE 58 51 SPARE 1 20 C 20 I SPARE 60 61 SPARE 1 20 A 20 I SPARE 62 63 SPARE 1 20 B 20 I SPARE 64 65 SPARE 1 20 C. 20 I SPARE 66 61 SPARE 1 20 A 20 I SPARE 68 6q SPARE 1 20 B 20 I SPARE 10 11 SPARE 1 20 0 20 I SPARE 12 13 SPARE 1 20 A 20 I SPARE 14 15 SPARE 1 20 5 20 1 SPARE 16 11 SPARE 1 20 G 20 1 SPARE 18 11 SPARE 1 20 A 20 I SPARE 80 81 SPARE 1 20 B 20 I SPARE 82 GGT TYPE: L= LIGHTING, R= REGEPTAGLE, M= MOTOR, LM= LARGEST MOTOR, E= EQUIPMENT, KE =KITGH EQUIP, S= SUBFEED PANEL OCT TYPE: LOAD MOLT DEMANDED LOAD LIGHTING: 0 1.25 0 VA RECEPTACLE: 0 I.0 0 VA OVER IOK: 0 0.5 0 VA MOTOR: 313312 I.0 313312 VA LGST MOTOR: 64848 1.25 81060 VA EQUIPMENT: 0 1.0 0 VA KITGH EQUIP: 0 0 0 VA SUBFEED PNL: 0 1.0 0 VA TOTAL CONNECTED LOADS A B G VA 126080 126080 126080 TOTAL DEMANDED LOADS A B G VA 131484 131484 131484 AMPS 415 415 415 TOTAL ON 314 KVA PANEL: 414 AMPS NOTES: ALL LOADS ON THIS PANEL ARE FUTURE. LOADS ARE SHOWN FOR REFERENCE ONLY. SEPARATE PERMIT REQUIRED FOR e Me chanical pectricsi tia-Plumbing 0.1eis NOV City of Tukwila r. 91'LD G AIVISiON j L REVISIONS No changes shall be made to the scope r m( without prior approval of ukwila Building Division. i 'TrZ: sons will require a new plan submittal and may include additional plan review fees. ELECTRICAL SPECIFICATION AND GENERAL NOTES THE GONTRAGTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM. MATERIALS AND INSTALLATION SHALL COMPLY WITH GODES, LAWS AND ORDINANCES OF FEDERAL, STATE AND LOCAL GOVERNING BODIES HAVING JURISDICTION. MATERIALS AND EQUIPMENT SHALL BE LISTED AND /OR LABELED BY U.L., ETL, GSA OR ANOTHER RECOGNIZED TESTING LAB. THE GONTRAGTOR SHALL SECURE AND PAY FOR ALL PERMITS, GOVERNMENTAL FEES, TAXES AND LICENSES NECESSARY FOR THE PROPER EXEGUTION AND GOMPLETION OF THE ELECTRICAL WORK. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO GOVERNMENTAL AGENCIES AND UTILITY COMPANIES SHOP DRAWINGS, WHICH ARE REQUIRED BY THESE AGENGIES, FOR THEIR APPROVAL. THE CONTRACTOR SHALL NOTIFY THE ENGINEER/OIAINER OF ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN VIOLATION OF LAWS, ORDINANCES, RULES OR REGULATIONS OF AUTHORITIES HAVING JURISDICTION. THE GONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE 51TE, AND THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS AND LOCAL GONDITIONS RELATING TO THE WORK. FAILURE TO DO 50 WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE GONTRAGT. ALL MATERIALS, AND EQUIPMENT SHALL BE ERECTED, INSTALLED, GONNEGTED, GLEANED, ADJUSTED, TESTED, CONDITIONED, AND PLACED IN SERVICE IN AGGORDANGE WITH THE MANUFACTURER'S DIRECTIONS AND RECOMMENDATIONS. ALL GUTTING, DRILLING AND PATGHING OF MASONRY, STEEL OR IRON WORK BELONGING TO THE BUILDING MUST BE DONE BY THIS GONTRAGTOR IN ORDER THAT HIS WORK MAY BE PROPERLY INSTALLED, BUT UNDER NO GONDITIONS MAY STRUCTURAL WORK BE GUT, EXCEPT AT THE DIREGTION OF THE ARCHITECT- DESIGNER OR THEIR REPRESENTATIVE. 10. SHOP DRAWINGS SHALL INCLUDE MANUFACTURER'S NAMES, CATALOG NUMBERS, GUTS, DIAGRAMS AND OTHER SUGH DESCRIPTIVE DATA AS MAY BE REQUIRED TO IDENTIFY AND REVIEW THE EQUIPMENT. SUBMITTALS SHALL BE IN LOGICAL GROUPS, FOR EXAMPLE, ALL LIGHTING FIXTURES, PARTIAL SUBMITTALS WILL NOT BE REVIEWED. II. SUBMIT DIGITAL COPIES OF THE FOLLOWING SHOP DRAWINGS FOR REVIEW. A. PANELBOARDS B. DISCONNECTS G. PROVIDE "AS- BUILT" DRAWINGS AND SUBMIT TO OWNER/ENGINEER. D. UPS E. BATTERIES 12. ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW, UNLESS SPEGIFIGALLY INDICATED AS EXISTING TO BE REUSED. 13. EXCEPT AS NOTED OTHERWISE, ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN ON DRAWINGS INCLUDING LABOR, EQUIPMENT AND MATERIALS SHALL BE IN STRICT GOMPLIANCE WITH THE BUILDING STANDARDS. 14. PROVIDE COMPLETE METAL RACEWAY SYSTEMS AND ENGLOSURES FOR ALL WIRING THROUGHOUT THE EXTENT OF THE REQUIRED SYSTEM. 15. ELECTRICAL METALLIC TUBING (EMT) SHALL BE USED FOR ALL WALL OUTLETS 4 TELEPHONE OUTLETS RUNNING IN PARTITIONS, BELOW RAISED FLOOR OR ABOVE CEILINGS. EMT FITTINGS SHALL BE OF THE STEEL COMPRESSION TYPE OR STEEL SET SGREW FITTINGS. 16. MINIMUM CONDUIT SIZE SHALL BE 3/4" UNLESS OTHERWISE INDICATED. 11. WIRE NO. 8 AND SMALLER FOR USE IN INTERIOR DRY LOCATIONS SHALL BE TYPE THWN/THNN THERMOPLASTIC 600 VOLT INSULATED GOPPER CONDUCTORS. FEEDERS AND POWER WIRING NO. 6 OR LARGER SHALL BE TYPE THWN 600 VOLT INSULATED COPPER. WIRE HIGH 15 INSTALLED IN RACEWAYS IN MOIST OR DAMP LOCATIONS SHALL BE TYPE XHHW, 600 VOLT INSULATED COPPER CONDUCTORS. NO WIRE SMALLER THAN NO 12 MG SHALL BE USED FOR LIGHTING OR POWER WIRING. WIRE NO. 10 AND SMALLER MAY BE SOLID OR STRANDED, WIRE NO. 8 AND LARGER SHALL BE STRANDED. I8. ALL NEV :CIRCUITS SHALL HAVE A GROUND WIRE INSTALLED. 11. ALL - WIRING' NOT INSTALLED IN GONDUIT AND INSTALLED IN THE GEILING SPACE SHALL BE PLENUM RATED. 20. ALL NEW GIRGUIT BREAKERS FOR NEW OR EXISTING PANELBOARDS SHALL MATGH EXISTING BUILDING PANELBOARD MANUFACTURER AND BREAKER TYPE. THE CONTRACTOR SHALL PROVIDE NEW TYPE WRITTEN PANEL DIRECTORIES' FOR ALL NEW PANELS AND EXISTING PANELS WHICH HAVE CHANGED. 21. ELEGTRIGAL GONTRAGTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT -MAY BE REQUIRED TO ENCLOSE RECEPTACLES. 22. IN SUSPENDED CEILINGS, SUPPORT CONDUIT AND JUNCTION BOXES DIREGT FROM THE STRUCTURAL SLAB, DECK, OR FRAMING PROVIDED FOR THAT PURPOSE. 23. SHOULD ACTUAL FIELD GONDITIONS REQUIRE INDICATED GIRGUIT DESIGNATIONS TO VARY, INDICATE THE GIRGUIT NUMBER USED ON THE "AS- BUILT" DRAWINGS. 24. G.G. SHALL INCLUDE IN HIS COST THE REMOVAL OF ALL EXISTING ELECTRICAL DEVICES, CONDUITS, FIXTURES AND EQUIPMENT. DISCARD ALL EQUIPMENT AS REQUIRED. E.G. SHALL BE RESPONSIBLE FOR DISCONNECTING PRIMARY SERVICE AND TEMPORARY POWER. 25. ALL EXISTING ELEGTRIGAL SERVICES NOT SPEGIFICALLY INDICATED TO BE REMOVED OR ALTERED SHALL REMAIN AS THEY PRESENTLY EXIST. 26. ALL EXTERIOR CONDUIT SHALL BE RIGID GALVANIZED STEEL (RCS). FILE COPY Permit No., L-1 ?- 0-7 phr r 'Aew approval is subject to errors and omlssions. 11 of construction documents does not aut or!o of any adopted code or ordinance. Receipt oa approved Field + = acknowledged: By Date: City OfTtdcwila BUILDING DIVISION REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC APR 19 2012 City of Tukxnla` —'— BUILDING DIVISION c48ftiA APR 1'22011 PERMIT CENTER :nN N X E in 0�C 0�" 3 Ln 'D• D O Oc Pi el Ot cu 17: • U N N m in 00 y > m Cd • a, 0 0 rn z 2 W W W J L) w 2 Li 0 0 Z w ce W Z w u 0 z W ce U z 0 M DESCRIPTION w ce CO 0 w Z 0 Z CO w CHECKED BY: N 0 N m O O ISSUE DATE: Copyright © 2009 - A 1 rights reserved Architectural Engineering Design Group, Inc. All design drawings and written material herein may not be used or duplicated without the written consent of Architectural Engineering Design Group, Inc. SHEET NO.: EO.O 1 PANEL 'HBO PANEL 'LB' TXG2 MGG ❑ UPS UP •■■■■i .9.L■.ea =ea= iEiiGiGGrliiii ■ ■ ■ ■ ■ ■■■■■■■ Mal MMM ..1111•1 111••••1/111111•1 UP 1E2011- ELECTR /CAL POWER PLAN DIA 1 Architectural Engineering Design Group, EXIST NG NEW PREPARED SPACE SWITCHBOARD SECTION NEW PREPARED SPARE SWITCHBOARD SECTION '01ST -DI' 'D15T -GI' 1 UP 1 v 3 FUSE EN f:R 0 v 01 I1 1 1 so UPS UIUPM -2 UP5 UIUPM -I PANEL 'HMI' GENERATOR SWITCHBOARD 0 \ PANEL 'HA' \ PANEL 'LA' GENERAL NOTES ALL EQUIPMENT SHOWN IN LIGHT PEN WEIGHT 15 EXISTING TO REMAIN, UON. TXMVIA LOSURE of EXISTING GENERATOR 2MW of EXISTING N -G RESISTOR of Ili•••••�IiuiI 1. 1111■■ ,1111 ■ ■I i■c:�i■1111■11■ii EXISTING GENERATOR 2MW of 0 //////////1 V / / / / / / / / / /.I Y//// / / / / / / / / / / / / / / / / / / / / / / / / / / / / /.I 1 ELECTRICAL POWER PLAN E2.0 SCALE: 1 /8" = 1' -0" 11 REVIEWED: FOR COMPLIANCE WITH NFPA70 -NEC APR 19 2012 City ofTukwila BUILDING DIVISION crtv�'�'.n APR :fi2 201 PERMIT CENTER in N G1 X n to 0 0 -m> u MN c u u O O LL C Doo M M 0 lei • p O: Ot V y > M M �C 0 0 W • W U Z Z u Z� L11 eev Z Uu W V1 W 2 li U fi z 0 V W z Z W U �z Qom0 I— 0 aw° oa Q N CI- Z 0 N I� W 0 9,4 U M M DESCRIPTION W cc W Z 0 Z 0 N_ M 0 0 W Z 0 u� = Z. W H Z U OQ 0 0 Copyright © 2009 - A 1 rights reserved Architectural Engineering Design Group, Inc. All design drawings and written material herein may not be used or duplicated without the written consent of Architectural Engineering Design Group, Inc. SHEET NO.: E2.0 Z CZ 0 v I- -±- tn GENERATOR SWITCHBOARD 0 \ PANEL 'HA' \ PANEL 'LA' GENERAL NOTES ALL EQUIPMENT SHOWN IN LIGHT PEN WEIGHT 15 EXISTING TO REMAIN, UON. TXMVIA LOSURE of EXISTING GENERATOR 2MW of EXISTING N -G RESISTOR of Ili•••••�IiuiI 1. 1111■■ ,1111 ■ ■I i■c:�i■1111■11■ii EXISTING GENERATOR 2MW of 0 //////////1 V / / / / / / / / / /.I Y//// / / / / / / / / / / / / / / / / / / / / / / / / / / / / /.I 1 ELECTRICAL POWER PLAN E2.0 SCALE: 1 /8" = 1' -0" 11 REVIEWED: FOR COMPLIANCE WITH NFPA70 -NEC APR 19 2012 City ofTukwila BUILDING DIVISION crtv�'�'.n APR :fi2 201 PERMIT CENTER in N G1 X n to 0 0 -m> u MN c u u O O LL C Doo M M 0 lei • p O: Ot V y > M M �C 0 0 W • W U Z Z u Z� L11 eev Z Uu W V1 W 2 li U fi z 0 V W z Z W U �z Qom0 I— 0 aw° oa Q N CI- Z 0 N I� W 0 9,4 U M M DESCRIPTION W cc W Z 0 Z 0 N_ M 0 0 W Z 0 u� = Z. W H Z U OQ 0 0 Copyright © 2009 - A 1 rights reserved Architectural Engineering Design Group, Inc. All design drawings and written material herein may not be used or duplicated without the written consent of Architectural Engineering Design Group, Inc. SHEET NO.: E2.0 Apr 11, 2012 1253pm ci ,01 FEEDER SCHEDULE KEY/ AMPS FEEDER CONDUIT AND GONDUGTORS KEY/ AMPS FEEDER CONDUIT AND CONDUCTORS SERVIGE EN-MANGE FEEDERS 5D5 XFMR FEEDERS (NOTE I) 400N 2[4#3/0, 2 "G] 308 4 #10, I #86, 3/4 "C SOON 2[4#350, 3 "C] 505 4#6, I #86 I -I /4 "G BOON 2[4#500, 3- I /2 "G] 1005 4#I, I #66 I -1 /2 "G 1000N 3[4 #400, 3- I /2 "G] 1505 4 #I /O, I#66, 2 "0 1200N 4[4#350, 3 "0] 2505 4 #250, I #26, 3 "C 1600N 5[4#400, 3- 1 /2 "G] 4005 2[4#3/0, 1 #26, 2 "G] 2000N 6[4#400, 3- I /2 "C] 5oo5 2[4#250, I #I /OG, 3 "G] 2500N 1[4 #500, 3- I /2 "G] 8005 2[4 #500, I #2/O6, 3- I /2 "C] 3000N 8[444500, 3- I /2 "G] 10005 3[4#400, 1 #4 /O6, 3- I /2 "C] 3500N 10[4 #500, 3- 1 /2 "0] 16005 5[4#400, 1#506, 3- 1/2 "G] 4000N 11[4#500, 3- I /2 "G] 25005 1[4 #500, I #5006, 3- I /2 "C] EQUIPMENT FEEDERS 2ON6 4 #12, #126, 3/4 "C 206 3#12, #126, 3/4 "G 30N6 4 #10, I #IOC, 3/4 "G 3oc 3#IO, I #106, 3/4 "G 4ONG 4 #8, I #106, I "G 406 3 #8, I #106, PG 50N6 4#6, I #106, I-1/4"C 506 3#6, I #IOC, I "G GONG 4#4, I #106, I -1 /4 "G 606 3#4, I #106, I "C TONG 4 414, I #86, I-1/4"C 1O6 3 #4, I #86, I -I /4 "G SONG 4#3, I #86, I -1/4 "0 806 3#3, I #86, I -1/4 "0 GONG 4#2, 1 #86, I -1 /2 "G 906 3 #2, I #86, I -1 /4 "C 100% 4 #I, I #86, 1 -1 /2 "G 1006 3 #1, I #86, 1 -1 /2 "G IIONG 4#I, 1#66, 2 "0 1106 3 #I, 1#66, I -1 /2 "G 125N6 4#1/0, 1#66, 2 "0 1256 3 #I /O, I#66, 1 -1/2 "0 'SONG 4#1/0, I #6G, 2 "G 1506 3 #I /O, I#66, 1 -1/2 "0 115N6 4#2/0, 1#66, 2 "0 1156 3 #2/0, I#66, 2 "G 200N6 4*3/0, I#66, 2 -I /2 "C 200G 3#3/0, 1#66, 2 "0 225N6 4#4/0, 1#46, 2 -I /2 "G 2256 3#4/0, I#66, 2 "C 25ONG 4 #250, I #46, 3 "0 2506 3 #250, I #46, 2 -1 /2 "C 300NG 4#350, I #46, 3 "0 3006 3 #350, I #46, 2 -I /2 "G 350N& 4#500, I#36, 3 -1 /2 "C 3506 3#500, I #36, 3 "G 400N6 2[4#3/0, I#36, 2- I /2 "C] 4006 2[3#3/0, 1#36, 2 "0] 450N6 2[4 #4/0, I #26, 2- 1/2 "C] 4506 2[3#4/0, I #26, 2 "0] 500NG 2[4#250, I #26, 3 "0] 5006 2[3 #250, I #26, 2- 1/2 "C] 600N6 2[4#350, I #IG, 3 "G] 6006 2[3#350, I #IG, 2- I /2 "C] -1OONG 2[4#500, I #1 /Os, 3- I /2 "G] 1006 2[3#500, I 441 /O6, 3 11G] SOONG 2[4#500, I #I /06, 3- I/2 "0] 8006 2[3 44500, I 4t1 /O5, 3 "0] I000NG 3[4#400, I #2/06, 3 "0] 10006 3[344400, I #2 /O6, 3 "0] 120oNG 4[4 #350, I#3/O6, 3 "0] 12006 4[3#350, I #3 /O6, 3 "0] 1600NG 4[444600, I#4/O6, 3- I /2 "C] 16006 4[3#600, I #4 /OG, 3- 1 /2 "G] 2000N6 5[4#600, I#4/06, 3-1/2"0] 20006 5[3#600, 1444/06, 3- 1 /2 "C] GROUNDING CONDUCTORS ABBREVIATIONS 68 1 #8, 3/4" G MEGH SEE MEGH SCHEDULE 66 I#6, 3/4" G XFMR SEE XFMR SCHEDULE 64 1#4, 3/4" G 22185 2 GIO 1 -I /O, 3/4" G 0.46 44,123 620 I -2/O, 3/4" G BP-CI 30 630 1 -3/0, 3/4" G 3 500 NOTES: 1. FEEDER FOR SECONDARY OF SEPARATELY DERIVED SYSTEM (595). GROUND SIZE PER NEG 250.66. 2. ALL CONDUCTORS ARE SINGLE GONDUCTOR COPPER THWN UNLESS NOTED OTHERWISE. AMPAGITY BASED ON NEC TABLE 310.16. 3. ALL CONDUITS ARE EMT UNLESS NOTED on IERWISE, FILL RATIOS BASED ON NEG ANNEX 0 TABLE G1. 1 1 OUTLINE OF SCOPE OF WORK UNDER THIS PHASE, ALL OTHER EQUIPMENT 15 EXISTING TO REMAIN. SENERAL NOTES I. NO NEW LOAD 15 ADDED UNDER THIS SCOPE OF WORK. DETAIL NOTES 0 FOR ALL KIRK KEY INTERLOCKS SHOWN INTERCONNECTED WITHIN THIS GEAR, THE INTERLOCK SHOWN AS NORMALLY GLOSED (NG) 15 THE PRIMARY BREAKER UTILIZED. UPON FAILURE OF THE FEED TO THIS BREAKER, THE OTHER NORMALLY OPEN (NO) BREAKERS GAN BE MANUALLY ENERGIZED THROUGH THE USE OF THE KIRK KEY INTERLOCKS. SKRU INTERLOCK SHALL PROVIDE A CLOSED TRANSITION TRANSFER BETWEEN BREAKERS IN ORDER TO MAINTAIN POWER TO DISTRIBUTION PANEL AT ALL TIMES. O 500KVA/SOOKW. 480/277V IN AND 480/2/1V OUT, 3PH, 311 UPS SYSTEM TO PROVIDE 8 MINUTES OF BATTERY BACKUP. (OWNER FURNISHED EQUIPMENT). O NEW FEED SHALL TIE INTO EXISTING GIRGUIT BREAKER WITHIN SWITGHBOARD SHA': O PANEL SHALL BE PROVIDED WITH 2000/3P GIRGUIT BREAKER FOR ROLL UP GENERATOR CONNECTION TO BE CAPABLE OF BACKING UP THE ENTIRE 2000 AMP PANEL BOARD. 0 NEV' MEDIUM VOLTAGE GENERATOR SWITGHGEAR WITH PREPARED SPARE. NO NEW LOAD WILL BE ADDED DURING THIS SCOPE OF WORK. O NEW MEDIUM VOLTAGE GENERATOR SWITGHGEAR WITH PREPARED SPACE. NO NEW LOAD WILL BE ADDED DURING THIS SGOPE OF WORK. O GIRGUIT BREAKER SHALL BE 100% RATED. 1111= ANN SWITCHBOARD SHA 3000A, 450/277V, 3PH, 41N 65KAIG 'DPI' 2000A DIST PANEL 480/271V, 3PH -4W, 65KAIG LOAD SUMMARY EXISTING LOAD ON SWITCHBOARD 'SHA'* FUTURE LOAD ON PANEL 'DPI' ** PANEL 'HMI' UPS -G1 UPS -DI 633 KVA 344 KVA 250 KVA 250 KVA TOTAL LOAD ON 'SHA' LOAD AT 480V/3PH 152'1 KVA 1831 AMPS SWITCHBOARD '5HA' 15 RATED AT 3000AMPS, THEREFORE THE LOAD 15 .AJSTIFIED. *EXISTING LOAD TAKEN FROM PREVIOUS ENGINEER'S DRAWINGS DATED 02/02/2011 * *FUTURE LOAD 15 SHOWN FOR REFERENGE ONLY. NO NEW LOAD SHALL BE ADDED DURING THIS PHASE. 5GL TRANSFORMER 4160/2400 DELTA SECONDARY r 1- OUTLINE OF SCOPE OF WORK UNDER THIS PHASE, ALL OTHER EQUIPMENT 15 EXISTING TO REMAIN. zu- 2 0 T MVI- TIE -GEN 0 ( GENERATOR O TIE BREAKER N 2000AF /'� t F 0 • GENERATOR^ 0(, 0 T BREAKER / 1200AF GEN -BKR -I MVIP 4160V DISTRIBUTION SWITGHGEAR 2000A. BUSSED FOR FUTURE CONNECTIONS' GENERATOR„ BREAKER (T 1200AF GEN -BKR -2 4/ 0 GENERATOR^ BREAKER (T 1200AF GEN- BKR -3 MVI 4160/2400V MAIN SWITGHGEAR 2000A _L FUTURE 2MW 2MW - 4160V - 4160V GENERATOR GENERATOR 4160V 480/27-15E0 T TXMV I A 2500 kVA Fo 2 M 416OV GENERATOR GENERATOR BREAKER( 1200AF \V Lr1 N 0) X :n O u td *0 >"- a) u M D 0 0 N �MM -01 o66', 3co G) i 0 y a 5OO > M M 3 0 O O 2MW 416OV GENERATOR 2000AF 2000AT LL 00. 4 00(0 NN 1 , 2000NG1 IL F2 00 p o0 I <o•)z o,) zo•) 0 0 O. 'BP -GI' 1200A PANEL 480V, 3PH -3W, 65K (OWNER FURNISHED) 12006 BATT 1GI- 13ATT3' BATT 'GI - BATT2' BATT GI- BATTI' 600A . • 6P--00A 600A n 8006 XF1 PS -0I' , cONVRTR �1 2[ #300 THHN, 2 "G] INVR. a - • 5 m 1 8006 1 F3 5 'UPS -D GONVRTR 1 12006 J 600NG XF1l PANEL 'HMI' 1 1 1 1 O ? • 4_ • < 1 d 1 �(• \• O 1 O (. O O O O (1 00 • • a FI 3000A 2 (3 #500MGM I #1/06 IN 3 I /2 "G) �'UIUPM -2' �'UIUPM -I' BATT BATT 'DI- BATT2' 'DI- BATTI' 600A n 60� BATT 'DI- BATT3' 600A 2[ #300 THHN, 2"G] 5000 1 1 SOOG SKRU 7 • 1200A3P 'NC' 12006 Flo UPS DISTRIBUTION GI PANEL 'DIST -0I' 1200A , 480V, 3PH -3W, 65K m 0 1 ! •)0D_•)0 IL • 0 •) 0E•' U1• MIN • 2 (3 #500MGM, I #I /06 IN 3 1 /2 "G) 800A • 1 800A n. 800A SPARE 800A SPARE • •-• lu 1 F50 2500A 480V 3 (6 #500MGM, I #2506 IN 4 "G) (3) 3 I /2 "G -EACH W/ 3- 500MGM, 3/OG m 0 O SKRU 52L • • 1200A3P 'NG' m 00 12006 xF6 1 1 PDU -2 PDU -3 PDU -4 1200A, 480V, 3PH PANEL 'UIPI -2' 100A/3P • IOOA/3P IOOA/3P • IOOA/3P 1 PDU 613 I -• • 100A/3P 1 PDU -7A �- - -y • 100A/3P PDU -9 P 1 PDU -I I 100 • ^ 100A/3P 100A/3P 1 I PDU -13 I 'BP-DI' 1200A PANEL 480V, 3PH -3W, 65K (OWNER FURNISHED) UP5 DISTRIBUTION DI PANEL 'DIST -17I' 1200A , 480V, 3PH -31A1, 65K l l l lf TD- j l l� 4 O< 1 1 SPARE MBP MEGH MEGH 'UISBM' 2000A, 480V SYSTEM BYPASS (6) 4 "G -EACH W/ 3- 500MGM, I #2506 1200A, 480V, 3PH PANEL 'UIPI -1' 100A/3P 100• A/5P I OOA/3P IOO• A/3P 100▪ A/5P 100• A/5P 100A/3P 100A/3P SP▪ ARE IOOA/3P SPACE PDU -I PDU -5 I PDU -6A I 1 PDU -7B J IPDU -8I 1 PDU -101 1 PDU -12 1 1 MEGH MEGH 00 FUTURE FUTURE CHILLER CHILLER MEGH MEGH 1 MEGH MEGH MEGH EXISTING ONE -LINE DIAGRAM ELECTRICAL ONE -LINE DIAGRAM E3.0 SCALE: NONE MGG -I, 600A 480/277V PANEL 'HA' FUTURE TXG -I 75kVA TRANSFORMER 480V PRIMARY 208 /120 SECONDARY PANEL 'LA' 0(• <( of <( 0( ( <( 0 • 0. • N • 0- • 0 • D- • Q • N N N Ul to N N PANEL 'HB' Fr TXG -2 75kVA TRANSFORMER 480V PRIMARY 208/120 SECONDARY PANEL 'LB' REVIEWED FOR - COMPLIANCE EC WITH NFPA APR 192012 City of Tukwila )ING DIVISION FAULT CURRENT CALCULATION SCHEDULE Du POINT LOCATION DESCRIPTION LENGTH (L) (ft) VOLTAGE (EL -L) VOLTAGE (EL -N) PHASE WIRE SIZE CONDUCTOR MATERIAL CONDUCTOR TYPE CONDUIT MATERIAL VOLTAGE GLASS G VALUE # OF PARALLEL RUNS Isc AVAILABLE UPSTREAM f L -L M L -L I9G AT EQUIP (13ph) OR (IL -U POINT FO MV SECONDARY -- -- -- -- -- -- 60,142 FO Fl PANEL SHA 25 480 211 3 500 COPPER THREE SINGLE CONDUCTORS STEEL 600V 22185 8 60,142 0.03 0.q1 58,358 Fl F2 PANEL DPI 50 480 21/ 3 400 COPPER THREE SINGLE CONDUCTORS STEEL 600V 20565 6 58,358 0.01 O.cI2 53,110 F2 F3 UPS-DI 35 480 211 3 500 COPPER THREE SINGLE CONDUCTORS 5TEEL 600V 22185 2 53,110 0.15 0.81 46,633 F3 F4 BP -DI 20 480 211 3 500 COPPER THREE SINGLE CONDUCTORS STEEL 600V 22185 2 46,633 0.08 0.43 43,345 F4 F5 BP -DI 20 480 211 3 500 COPPER THREE SIDLE CONDUCTORS STEEL 600V 22185 5 53,110 0.03 0.4/ 51,453 F5 F6 DIST -DI 30 480 211 3 500 COPPER THREE SINGLE CONDUCTORS STEEL 600V 22185 5 51,453 0.05 0.45 44,446 F6 F1 UPS-CI 40 480 211 3 500 COPPER THREE SINGLE CONDUCTORS STEEL 600V 22185 2 53,110 0.11 0.85 45,165 F1 F8 BP-GI 10 480 211 3 500 COPPER THREE SINGLE CONDUCTORS STEEL 600V 22185 2 45,165 0.04 0.46 44,123 F8 Fq BP-CI 30 480 211 3 500 COPPER THREE SINGLE CONDUCTORS STEEL 600V 22185 5 53,110 0.05 0.45 51,084 Fq FIO DIST -GI 20 480 211 3 400 COPPER THREE SINGLE CONDUCTORS STEEL • 600V 20565 5 51,064 0.04 0.41 44,321 FIO Fl PANEL HMI 20 480 211 3 350 COPPER THREE SINGLE CONDUCTORS STEEL 600V 14103 2 53310 0.10 0.41 48,150 Fl NOTES: I. ALL CALCULATIONS l^IERE DONE USING EUSSMAN "POINT -TO- POINT" METHOD. 2. REFER TO PLANS FOR ASSUMED UTILITY TRANSFORMER SIZE UTILIZED FOR CALCULATIONS. cmc�4��iu+ j� L �` 0 327 .: 012 1 w U �z Q �O < uSO < N CI- J � O J W Ce O U 2 w Q 0 DESCRIPTION w CO O Lf; N. N. w Z 0 Z CO w 0 W 04/03/2012 ISSUE DATE: N z 0 Ur Z 15- W 0U U 0 0 O Copyright © 2009 - A I right reserved Architectural Engineering De Ign Group, Inc. All design drawings and written material herein may not be used or duplicated without the written consent of Architectural Engineering Design Group, Inc.' a W U z 2 - U w WZ< wOO SHEET NO.: E3.0