Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL12-0362 - WESTFIELD SOUTHCENTER MALL - THE ART OF SHAVING
ART OF SHAVING, THE 201 S 0 UTH CENTER MALL EL1 2-0362 City o*Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 9202470010 Address: 201 SOUTHCENTER MALL TUKW Project Name: ART OF SHAVING, THE ELECTRICAL PERMIT Permit Number: EL12 -0362 Issue Date: 05/30/2012 Permit Expires On: 11/26/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: PHILIP FOSTER Address: 219 N 2 ST, STE 301 , MINNEAPOLIS MN Contractor: Name: CEDAR GROVE ELECTRIC INC Address: 1819 CENTRAL AVE S SP 71 , KENT WA Contractor License No: CEDARGE955BC Phone: 612 338 -6677 Phone: 253 - 373 -0056 Expiration Date: 01/21/2013 DESCRIPTION OF WORK: TENANT BUILD OUT: EXISTING PANEL AND SERVICE TO REMAIN WITH NEW DISTRIBUTION WITHIN LEASED SPACE Value of Electrical: NRES: $9,400.00 RES: $0.00 Fees Collected: $330.63 Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: 2008 Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: (4).;11„ Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of,w_orkk.. I am authorized to sign and obtain this electrical permit. (2.4/1A- Signature: Print Name: Date: 5 - o -2t2_- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL12 -0362 Printed: 05 -30 -2012 • • PERMIT CONDITIONS Permit No. EL12 -0362 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -0362 Printed: 05 -30 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://vvww.TukwilaWA.gov Electrical Permit No. L42 092(.01. Project No. Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax: * *Please Print ** SITE LOCATION Site Address: Southcenter Mall King Co Assessor's Tax No.: 41,909-A-1 170 IQ Suite Number: 632 Floor: 1 Tenant Name: The Art of Shaving New Tenant: m Yes ❑..No PROPERTY OWNER Name: Philip Foster Address: 219 North 2nd Street, Suite 301 Name: Westfield Phone: (612) 338 -6677 Fax: (612) 338 -2995 Email: pfoster @cmarch.com Address: 2800 Southcenter City: Seattle State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Philip Foster Address: 219 North 2nd Street, Suite 301 City: Minneapolis State: MN Zip: 55401 Phone: (612) 338 -6677 Fax: (612) 338 -2995 Email: pfoster @cmarch.com ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 50,000 Scope of Work (please provide detailed information): Tenant build out of existing retail space. Existing panel and service to remain, new distribution within leased space. Will service be altered? ❑ Yes gj No Type of Use: Mercantile Type of work: • New ❑ Addition ❑ Low Voltage ❑ Generator Pro.ert ' Served b : Puget Sound Energy ❑ Seattle City Light Adding more than 50 amps? ❑ Yes 1 No ❑ Service Change ❑ Fire Alarm H:\ Applications \Forns - Applications On Line \2011 Applications \Electrical Permit.Application Revised 8- 9- 11.docx Revised: August 2011 bh ❑ Remodel ❑ Telecommunication ❑ Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added /altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added /altered without service change $54.60 (up to 5 circuits) ❑ Circuits added /altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured /mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no pemfit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF TI-IE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: 42Ai4- PrintNan: aY SC -1 rzi CJZ- Date: 64-( / ISS% I Z. Day Telephone: 32-3-5 7S- `3 -!4 Mailing Address: ZgGV OV %Ufrti)ILA city H: \Applications \Forms - Applications On Line \2011 Applications \Electrical Permit Application Revised 8 -9 -1 l.docx Revised: August 2011 bh State Zip Page 2 of 2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL12 -0362 Address: 201 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/18/2012 Applicant: ART OF SHAVING, THE Issue Date: Receipt No.: R12 -01722 Initials: User ID: Payee: WER 1655 Payment Amount: $92.50 Payment Date: 05/30/2012 09:14 AM Balance: $0.00 MEL CAMAT TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA RD Pmts Re -Dist OP Authorization No. 09591G ACCOUNT ITEM LIST: Description 92.50 .00 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 ELECTRICAL PLAN - NONRES 000.345.832.00.00 Total: $92.50 264.50 - 172.00 doc: Receiot -06 Printed: 05 -30 -2012 Cif of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukw ila. wa. us SET RECEIPT RECEIPT NO: R12 -01358 Initials: JEM Payment Date: 04/18/2012 User ID: 1165 Total Payment: 351.40 Payee: C.M. ARCHITECTURE, P.A. SET ID: S000001738 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member EL12 -0362 M12 -067 PG12 -059 TOTAL: Amount 238.13 85.71 27.56 238.13 TRANSACTION LIST: Type Method Description Amount Payment Check 119738 351.40 TOTAL: 351.40 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 238.13 113.27 TOTAL: 351.40 INSPE!TION NO..: CITY"OF'TUKWILA BUILDING DIVISION '6300 Southcente'rBlvd., #100, Tukwila. WA 98188 2 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 INSPECTION RECORD Retain a copy with permit 6(2-6 341. PERMIT NO. Project: < /,, jj OC �✓144 cJ Type of Inspection: Poo Address: 7-=0:1 1i Date Called: Special Instructions: Date Wanted:. 0 a:m: Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval., COMMENTS: 6110,110"),S rtri)f- Date: 07/02.b1, REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300'Southcenter Blvd.. Suite 100. Call to schedule reinspection. le*_��.. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 6 tQ (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: /� „�_ Of- /� o-r� j �/ Type of Inspection: O� — Pcii 'r 604.4- Tu Se( s tAt Address: �^ G4)(. Date Called: Special Instructions: Date Wanted:. 6 �,g a. p . m Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /. rVI t , - W tri- f • n f qr ' f or so k, — Pcii 'r 604.4- Tu Se( s tAt Roousr 4-41 I4ar AV -c 4- To ct-k,es5 ,T Inspector: Date: / tO 2i n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Ims :INSPECTION RECORD 4 /,` 034 `Retain a copy with permit INSPECTION NO ` : PERMIT NO. :CITY; :OF'TUKWILA BUILDING DIVISION 6300 Southcenter B1ud., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection ;Request Line (206) 431 -2451 Project Type of Inspection: 700) Address � r -�Ali( i Date Called: Special 'Instructions: _: ;: Date Wanted:. 4 f,ij "gym. Requester: Phone No Approved per applicable codes. Corrections required prior to approval. COMMENTS: (-14lCIVID Inspector: t. . REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: d‘ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 v (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: 1 (, Address: Type of Inspection: Zot M4- Special Instructions: Date Called: Date Wanted: Requester: �oa3 Os- a.m. pm Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: Date: 06oc.12..... n REINSPECTION FEE REQUrRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2009 Washington State rgy Code Compliance- Form•forNonresidentlal an ultifamiiy Resldentlal Project Summary PRJ -SUM 2009Washington 'State `Energy Code Compliance Forms for Noriresldential and Multifamily, Residential Revlsedipecember2010 Project Info Protect Address The Art of Shaving Date 3 /2e /2012 2800 Southcenter Mall For Building Department Use aeattle, WA 53226 Applicant Name: Keith O'Brien Applicant Address: Minneapoiie, Kg Applicant Phone: 952 - 540 -4034 FILE COPY Permit No. REVIEWED .1-UK COMPLIANCE WITH NFPA70 - NEC APR 1 9 2012 C' Tukwila BUILDING DIVISION clTRYo 'TIKWLA u? 18 2012 !" PERMIT CENTER E Li9:„..0&p2 2009 Washington State IllPgy Code Compliance Form-for Nonresidential an IP ultifarni Residential Interior Lighting Summary LTG-INT 2009 Washington State Energy Code Compliance.Fonne for Nonresidential andMultitamily Residential Revised t December 2010 Project Info PrblOct Ad0ress .The At of iihovfog Date . 3/28/2012 2000 Southcenter Mill .. . For Building Department Use . . Seattle. MA 53224 ' Applicant Name: 'Keith O'Brien ' .. ..... .. . Applicant Address: milinea.,,lia, . . . '7 Applicant Phone: 932-540-4034 'Project bescription . . . . . , NeviBuilding - Addition 4 Alteration Plan.s Induded Refer to WSEC Section 1513 for.controls and commissioning requirements: Compliance opfion 0 Prescriptive C) Lighting Power AllowanCe 0 Systems Anaiysis (See Qualification Checklist(over). Indicate Prescriptive & LPA spaces dearly onptans.) Alteration Exceptions (check appropriate box - sec..112.3) No changes are being made to the lighting and space use.not changed Less than 60% of the fixtures' new. Installed wattage•not Me:eased.- &space use not changed. Maximum Allowed Lighting Wattage Location (floor plan/room #) Occupancy Descriptkin Allowed watts per ft2... Gross Interior Area in tt2 Allowed x Area Sales 1.331, 507. 674 Storage 0.50 266 133 . . . . . Mastro= 0.80 57 46 Additional 1000 watt 1.00 1000 1000 .. 8 i 50 , ........ 30 3 90 rom Table 15-1 over - document all exceptions on form LTG-IPA Proposed Lighting Wattage Total Allowed Watts 1853 Location (floor plan/room #) . . .. Fixture Description Number of Flittures Watts/ Fixture Watts Proposed A ,,Recessed adjustable Accent light 13' 48, 624 8 7-Riceised doWnlight 8 35 280 , ci 4'. strip fluOreicent .. . 1 52 52 C2- 4' .trip 41Uoreicant 4 52 208 a 1.track ,' 8' 8 i 50 to o 7 ,Mt0 30 3 90 II '...Meceamed adiUmtahle wall wash, . . 35 35 P1 • Pendant cylinder .. . 2 70 140. otai Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts' 18291 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps In-the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) In addition to the fixttire, lamp, and ballast Information. 2. For proposed Watts/Fixture, use manufacturer% listed maidrnurn Input Wattage of the fixture (not simply the lamp wattage) and Other Criteria as specified In Section 1530. For line voltage track lighting, fiat the greater of actualluminaire wattage or bangth of track Multiplied by 50; or as agplICade, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave VVatts/Fixttire blank. 2009 Washington State Orgy Code Compliance Form for'Nonresidentiat anultifamily Residential Interior Lighting Summary (back) LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and MultifamIly Residential Ravi Prescriptive Spaces Occupancy: i0 Warehouse or Parking Garage QQ Other Qualification Checklist Note: If occupancy type Is "Other and fixture Lighting Fixtures: O Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 'e)1 "bjreflectoror answer checked; the number of fixtures In the spice Is not limited by Code. Geary (Section. 1521) 1. Fluorescent fixtures with or two tamps, louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T-8, or CFL lamps, and d) hard -wired electronic Indicate these spaces on :plans. If not qualified, do LPA' Calculations. :0.20 dimniIng ballasts. Screwan CFL fixtures,and tracking lighting do not qualify. 1.10 Penitentiary and other.Group 1 -3 Occupancies 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts Cafeterias, fast food establishments °, restaurants/bars'' . . 1.20 3. LED lights. 15-1 Unit LIsthtin Power Allowance (LPA)' Use' LPA (W /ft`) Use' LPA' (W/fe) 0.91 Automotive facility 0.85 Office buildings, office/administrative areas In facilities of other use types (inCuding but not limited to schools; hospitals; institutions, museums, banks, churches? Convention center 1.10 Parking garages :0.20 Courthouse 1.10 Penitentiary and other.Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments °, restaurants/bars'' . . 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office' . 1.00 Dweling Units 1 :00 Retail', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia. assembly spaces ... .. 0.95 Theater, motion picture' 0.97 Health care clinic 1.00 Theater,.pertorrning arts '1.25 Hospital, nursing homes, and other Group 1.1'and 1-2 Occupancies 1 :20 Transportation 0.80 _ 1.00 Warehouses 0.50 . Laboratory spaces (all spaces not dassified 'laboratory shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries° 1.20 . Submitted for Common Areas Only' Manufacturing facility 1.20 • Main floor building lobbies' (except mall concourses) . . 1.10 Museum 1.00 Common areas, corridors, toilet facilities and Washrooms, elevator lobbies 0.80 ootnotes for Table 1) .In cases In which a general use and a specific use are listed, the specific use shall apply. In cases in which a use Is not mentioned specifically, the Unit Power Allowance shall be determined by the'bulding offldal. This determination shali be based upon the most comparable usespecffied in the table..See Section 1512 for exempt areas. 2) The watts per square foot May be Inoreasedby 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may increased b•2% per foot of ceiling height above 12 feet.. 4) For all other spaces, 'Such as seatingand common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may beincreased by per foot of ceiling height above 9 feet. 6) Reserved: 7) For conference rooms end offices less than 150ft2 with full height partitions: a ,Unit Lighting Power Allowance of 1.1 w/ti2 maybe used. 8) Reserved. 9) For Indoor sport toumament courts with, adjacent spectator seating over 5,000. the Unit Lighting Power Allowance for the court area Is 2.60 W/ft2. 10) Oisplay window illumination installed within 2 feet of the window, provided that the display window Is separated from the retail space by wails or at least three= quarter - height partitions (transparentor opaque) and lighting for free- standing display where the lighting moves With the display are exempt.. An additional lighting power allowance is allowed for merchandise display tuminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: 1. 0.6 watts per square.foot of sales floor area net listed In items ti end ii below; 11.1A watts per square foot of fumlture, clothing,. cosmetics or artwork floor area or 111. 2.5 watts per square foot of jewelry, crystal or china floor area. The Scarified floor area for items i, li, or'111 above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above;LPDs by the sales floor area for each department exciudingmajor circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories 1,11, or111 plus an additionai 1.000 watts for each separate tenant larger than 250 square feet in area. The additional wattage Is,aflowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling-mounted track or directly on or. recessedlnto the•celiing itself (not on the wall). (b) Ad ustable in both the horizontal and vertical axes (vertical axis on is a j. .. ( ly cceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is,allowed only If the lighting Is actually Installed and automatically controlled. separately .from the general lighting, -to be turned off during nonbusiness hours. This additionatpower shall be used only for the specified luminaires end shall not be used for any other purpose. This additional lighting power IS-allowed only if the;flghtlng;ls actually Installed. 11) Provided that a floor plan. Indicating rack location and height, Is submitted, the square footage-for a warehouse may be defined, for computing the interior Unit Lighting PowerAllowance, as the floor area 'not covered by racks plus the vertical face area (accessside only) Of the racks. The height allowance defined In footnote 2 applies only to the floor area not covered by racks. IP 2 009 Washington State nergy Code Compliance ,Form for: Nonresidential and,Muttifamiy Residential' Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 20091Washington'State Energy Coda CampSante Form for'Nmvesidentiat andMottitamdly Restdentlal Revised "De ember 2010 ProjedAddress the ,itie or :saafiag 'Date 3/28/2012 The following, information is necessary to check a pemllt application for compliance with the lighting, motor, and transformer' requirements in the 2009 Washington State- Nonresidential Energy Code. Applicabiilty (yes, no, n e.) . Code ! Section Component Information Required Location' Ton Plans ' Building Department : Notes LIGHTING CONTROLS (Section: 1513) U.A. 1513:1 Local control/access . ,Schedute with.type, indicate Locations Yee 1513.2 Area controls Maximum limit per switch 83.2 N.A. 1513.3 Daytightzone control Schedule with type and features, Indicate locations N.A.. vertical,giazing . Indicate vertical glazing onplans N.k. , overhead glazing Indicate overhead glazing en Plans N.A. 1513.4 Display /exhib /special ,Indicate separate controls N.JC. 1513.5., Exterior shut -off Schedule with•type and features,; indicate location N.A. (a) timer w /backup Indicate tocatton .N•A• (b),photoCell. Indicate location N.A • 1513(6 ; Inter. auto shut -off Indicate location .Yee. 1511.0.1..: (a) occup. sensors Schedule.with type and` locations 31.2 N.A. , 1513:6.2 (b) auto. switches Schedute with type and features (back -up, override capability); Indicate,size of zone onplans_ Yee 1513.7. Hotei/motel controls Indicateiocation of room master controls N• A• 1513:8 Commissioning indicate requirements for lighting controls commissioning EXIT SIGNS(Section 1514) Yea 1514 JMax watts ' Indicate Viatts for each exit sign 131.3 I' LIGHTING POWER ALLOWANCE (Section 1,53104532) Yes 1531 Interior.Ughting Summary Form Completed'andattadied. Schedule with:flxturetypes, tamps, ballasts, watts per fixture 31.3 N.A. '1532 • Exte for Lighting Summary Form . Completed end attached. Schedule with fixture types, tamps, ballasts, Watts per fixture MOTORS (Section 1511) Yee 1511 Elec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency jai.* s I; TRANSFORMERS (Section 1540) Yee' 1 1540 Transformers Indicate size and efficiency Ie1..3 I "no" Is circled for any question, provide explanation: May 30 12 08:51a Cedar Grove Electric Inc 4254270899 p.1 • • Cedar Grove Electric, Inc The Art of Shaving, Seattle, WA PROJECT# 27 -12 -0135 01 This' SubContract must be signed and returned before any work is performed. Subcontractor will be held to the following additional requirements: .1. Before and as a condition of receiving the first draw, which can be no more than 50% of contract amount, the subcontractor is required to list all material suppliers that may provide material or supplies on the job on form titled Supplier List on Horizon Retail Construction Protect as we'd as sign the Declaration at the bottom of this form declaring the information to be true and correct. 2. Before and as a condition of receiving the more than 50% of contract amount, the subcontractor will need to provide final unconditional material lien waivers from all material suppliers used. 3. At the discretion of Horizon Retail Construction, the subcontractor may be requested to update the form titled Supplier List on Horizon Retail Construction Project as well as sign the Declaration at the bottom of this form before receiving either the second or final draw on this project. 4. Do NOT hold retention: Invoice 100% or per terms of Subcontract, or your invoice will be rejected. 5. Payment for all work completed under this construction contract shall be paid as follows: Nei 30 CHANGE ORDER PROCEDURE: 1. Additional work WILL NOT be authorized in the field. 2. To obtain a signed change order you must forward a detailed proposal including cost breakdown into man hours and material in a timely manner. A written change order signed by Nick Serbian. prior to doing any extra work is required for payment. Consideration for any work over the original contract amount without a written change order signed by Nick Serbian will be null & void. 3. CONTRACT AMOUNT Description Amount Electrical $9,400.00 Total $9,400.00 ALL AMOUNTS INVOICED SHOULD INCLUDE APPLICABLE SALES / USE TAX AND AMOUNTS SHOULD BE SEPARATELY STATED. • SUBCONTRACTOR DATES COMMENCEMENT DATE 5!16!2012 ROUGH INSPECTION DATE 5/31/2012 FINAL COMPLETION DATE 6/22/2012 MATERIAL DELIVERED BY PAYMENT TERMS ! CONTRACT ACCEPTANCE: I agree to the scope of work, payment terms, insurance requirements and change order procedures as stated in this Construction Contracts. THIS COMPLETED PAID SIGNED CONSTRUCTION CONTRACTS TOGETHER WITH YOUR INSURANCE CERTIFICATE & W9 MUST B, EIVED BEFORE COMENCING THE SUBCONTRACTED WORK. • • T Nick Serbian Horizon makes every effort to issue payment within 30 -45 days from invoice RECEIPT DATE. Failure to provide requested documentation or to properly invoice will result in delays of payment. All payments to subcontractor are contingent and not cue until the project owner's fulfillment, including payment, of their contract obligations with Horizon Retail Construction, Inc. Horizon Retail Construction, Inc. reserves the right to make payment only after receiving corresponding payment from the owner. 1500 Horizon Drive Sturtevant WI 53177 262 -638 -6000 phone 262 - 638 -6015 fax Sign`�fylJe. Vendor Required for Payment / Date Feder ID .4 •— 1'2_6141-ORS- Name that corresponds to Federal ID: Cedar Grove Electric, Inc. Subcontract #:27 -12 -0135- 01 5/10/12 3 RECEIVED 05- 30 -'12 08:52 FROM- 4254270899 TO- publicworks /dcd P0001/0001 ;» PERMIT COORD CAPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0362 PROJECT NAME: ART OF SHAVING, THE SITE ADDRESS: 201 SOUTHCENTER MALL DATE: 04/18/12 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: J�j �c -GCS n uilding'Divi n 11111 Fire Prevention Public Works ❑ Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 04/19/12 Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route-71 Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/17/12 Approved n Approved with Conditions g Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire EJ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 02/29/12 Contractors or Tradespeople P ter Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company CEDAR GROVE ELECTRIC INC 4254279218 16825 230Th Ave Se Maple Valley WA 98038 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602254353 Active CEDARGE955BC Electrical Contractor 1/21/2005 1/21/2013 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status CEDARGE995DW CEDAR GROVE ELECTRIC Electrical Contractor General Unused 3/16/2001 3/16/2005 Archived Master Electrician INFORMATION License BATTEJT967C5 Name BATTERSON, J T Status Active Business Owner Information Name Role Effective Date Expiration Date BATTERSON,J T Agent 01/03/2005 Bond Amount BATTERSON, J T President 01/03/2005 9805393 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 Lexon Ins Co 9805393 04/29/2011 Until Cancelled 19.28.271 RCW ELECTRICAL CITATION $4,000.00 04/20/2011 2 COLONIAL AM CAS Et SURETY OF MARYLAND - LPM4068727 04/29/2005 Until Cancelled 06/03/2011 $4,000.00 05/09/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EMABQ03686 10/22/2011 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EHOUD00355 3/22/2008 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni /bbip /Print.aspx 05/30/2012 1:55:27 PM kobrien — 3/30/2012 K: \Projects \3292.0034 TAOS Southcenter Seottle WA \3292.0034 E1.1,dwg SECTION 16 0500 - COMMON WORK RESULTS FOR ELECTRICAL 1.1 COMMON REQUIREMENTS FOR ELECTRICAL INSTALLATION A. Comply with NECA 1. B. Measure indicated mounting heights to bottom of unit for suspended items and to center of unit for woII- mounting items. C. Heodroom Maintenance: If mounting heights or other locution criterio ore not indicated, arrange and install components and equipment to provide maximum possible heodroom consistent with these requirements. D. Equipment: Install to Iacilitote service, maintenance, and repair or replacement of components of both electrical equipment and other nearby installations. Connect in such o woy os to facilitate future disconnecting with minimum interference with other items in the vicinity. E. Right of Way: Give to piping systems installed of o required slope. F. Contractor sholl provide rough -in for and connect to the following equipment furnished by others. Equipment will be provided by other contractors or owner. Secure rough -in information, connection requirements, and templates from equipment supplier. Verify all equipment voltage and power requirements: 1. Plumbing and HVAC equipment. 2. Electric motors. 1.2 FIRESTOPPING A. Apply firestopping to penetrotions of fire -roted floor and woll ossemblies for electricol instollations to restore original tire- resistonce roting of ossembly. Firestopping moleriols and instollotion requirements ore specified in Division 07 Section "Penetration Firestopping" 1.3 EXISTING MATERIALS A. Where existing moleriols or equipment are noted to be reused, Contractor shall assume in his bid that the moteriol or equipment is in good working condition and con be reused without any repoirs. If certain items ore found to be in need of repoir or in unusable condition, Contractor shoo notify Engineer for decision, however. Contractor sholl be responsible for ony damage coused by him to equipment in removal or handling. B. Fixtures and other equipment removed and to be reused shall be cleoned before reinstallation. New lamps shall be provided for all reused fixtures. 1.4 SEISMIC REQUIREMENTS C. Provide brocing and supports to meet code required seismic ratings. SECTION 16 0519 - LOW- VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 1.1 SUMMARY A. This Section includes the following: 1. Building wires and cables rated 600 V and less. 2. Connectors, splices, and terminations rated 600 V and less. 1.2 QUALITY ASSURANCE A. Electrical Components, Devices, end Accessories: Listed and labeled as defined in NFPA 70, Article 100, by o testing ogency acceptable to outhorities having jurisdiction, and morked for intended use. B. Comply with NFPA 70. 1.3 CONDUCTORS AND CABLES A. Copper Conductors: Comply with NEMA WC 70. B. Conductor Insulation: Comply with NEMA WC 70 for. Types THHN -THWN. C. Multi- conductor Coble: Comply with NEMA WC 70 for metol -clod cable, Type MC with ground wire. 1.4 CONDUCTOR MATERIAL APPLICATIONS A. Feeders: Solid copper for No. 12 AWG and smaller; stranded copper for No. 10 AWG and larger. B. Bronch Circuits: Copper. Solid copper for No. 12 AWG and smaller; stronded copper for No. 10 AWG and larger. 1.5 CONDUCTOR INSULATION AND MULTI - CONDUCTOR CABLE APPLICATIONS AND WIRING METHODS A. Feeders Conceoled in Concrete. below Slobs -on- Grode, and Underground: Type THHN -THWN, single conductors in raceway. B. Exposed Bronch Circuits, Including in Crowlspoces: Type THHN -THWN, single conductors in raceway. C. Branch Circuits Concealed in Ceilings, Walls, and Partitions: Type THHN -THWN, single conductors in rocewoy or Metal -clod cable, Type MC. D. Brunch Circuits Concealed in Concrete, below Slabs- on- Grode, and Underground: Type THHN -THWN. single conductors in rocewoy. 1.6 INSTALLATION OF CONDUCTORS AND CABLES A. Conceal cables in finished walls, ceilings, and floors, unless otherwise indicated. B. Install exposed cables parallel and perpendicular to surfaces of exposed structural members, and follow surface contours where possible. SECTION 16 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS 1.1 SUMMARY A. This Section includes methods and materials for grounding systems and equipment. 1.2 QUALITY ASSURANCE A. Electrical Components, Devices, and Accessories: Listed and lobeled os defined in NFPA 70, Article 100, by o testing ogency occeptoble to outhorities having jurisdiction, and marked for intended use. B. Comply with UL 467 for grounding and bonding moleriols and equipment. 1.3 APPLICATIONS A. Conductors: Install solid copper conductor for No. 12 AWG and smaller, and stranded copper conductors for No. 10 AWG and forger, unless otherwise indicated. 1.4 EQUIPMENT GROUNDING A. Install insuloted equipment grounding conductors with the following items, in addition to those required by NFPA 70: 1. Feeders and branch circuits. 2. Lighting circuits. 3. Receptacle circuits. 4. Single -phose motor and opplionce bronch circuits. SECTION 16 0529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS 1.1 SUMMARY A. Section includes: 1. Hongers and supports for electricol equipment and systems. 2. Construction requirements for concrete boses. 1.2 PERFORMANCE REQUIREMENTS A. Design supports for multiple raceways copoble of supporting combined weight of supported systems and its contents. B. Design equipment supports capable of supporting combined operating weight of supported equipment and connected systems and components. 1.3 QUALITY ASSURANCE A. Comply with NFPA 70. SECTION 16 0533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS 1.1 SUMMARY A. This Section includes rocewoys, fittings, boxes, enclosures, and cobinets for electrical wiring. 1.2 OUALITY ASSURANCE A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, Article 100, by o testing ogency occeptoble to authorities having jurisdiction, and morked for intended use. B. Comply with NFPA 70. 1.3 METAL CONDUIT AND TUBING A. Rigid Steel Conduit: ANSI C80.1. B. EMT: ANSI C80.3. C. Fittings for Conduit (Including 011 Types and Flexible and Liquidlight), EMT, and Coble: NEMA FB 1; listed for type and size raceway with which used, and for application and environment in which installed. 1. Conduit Fittings for Hazardous (Classified) Locotions: Comply with UL 886. 2. Fittings for EMT: Steel, set - screw. or compression type. 1.4 NONMETALLIC CONDUIT AND TUBING A. RNC: NEMA TC 2, Type EPC -40 -PVC, unless otherwise indicated. B. LFNC: UL 1660. C. Fittings for RNC: NEMA TC 3; motch to conduit or tubing type and material. D. Fittings for LFNC: UL 514B. E. Nonmetallic conduits is ollowed below slab on grade only. 1.5 BOXES, ENCLOSURES, AND CABINETS A. Sheet Metal Outlet and Device Boxes: B. Cast - Metol Outlet and Device Boxes: C. Nonmetallic Outlet and Device Boxes: 1.6 RACEWAY APPLICATION A. Comply with the following indoor applications, unless otherwise indicated: 1. Exposed. Not Subject to Physicol Domoge: EMT. 2. Exposed, Not Subject to Severe Physical Domoge: EMT. .3. Exposed and Subject to Severe Physicol Damage: Rigid steel conduit. 4. Conceoled in Ceilings and Interior Walls and Partitions: EMT. 5. Connection to Vibrating Equipment (Including Tronsformers and Hydroulic, Pneumatic. or Motor- Driven Equipment): FMC. except use LFMC in damp or wet locations. 6. Damp or Wet Locotions: Rigid steel conduit. 7. Boxes and Enclosures: NEMA 250, Type 1, except use NEMA 250, Type 4, nonmetallic in damp or wet locations. NEMA OS 1. NEMA FB 1, aluminum, Type FD, with gosketed cover. NEMA OS 2. Electric Solenoid, SECTION 16 0553 - IDENTIFICATION FOR ELECTRICAL SYSTEMS 1.1 SUMMARY A. Section Includes: 1. Identification for raceways. 2. Idenlificotion of power and control cables. 3. Identification for conductors.. 4. Equipment identification labels. 5. Miscelloneous identification products. 1.2 EQUIPMENT IDENTIFICATION LABELS A. Self- Adhesive, Engraved, Laminated Acrylic or Melomine Lobel: Adhesive bucked, with white letters on o dork -groy bockground. Minimum letter height shall be 3/8 inch. 1.3 IDENTIFICATION SCHEDULE A. Power - Circuit Conductor Identification, 600 V or Less: For conductors in voulls, pull and junction boxes, manholes, and hondholes. use color- coding conductor tope to identify the phase. 1. Color- Coding for Phose Identificotion, 600 V or Less: Use colors listed below for ungrounded conductors. a.- Color shall be factory applied or field applied for sizes larger than No. 8 AWG, if authorities having jurisdiction permit. b. Colors for 208 /120 -V Circuits: 1) Phose A Block. 2) Phose B: Red. 3) Phase C: Blue. B. Equipment Identificotion Lobels: On each unit of equipment, install unique designation label that is consistent with wiring diagrams, schedules, and the Operation and Maintenance Manual. Apply lobels to disconnect switches and protection equipment, central or master units. control panels. control stotions, terminal cabinets. and rocks of each system. Systems include power, lighting, control, communicotion, signal, monitoring, and olorm systems unless equipment is provided with its own identificotion. SECTION 16 2416 - PANELBOARDS 1.1 SUMMARY A. Section includes lighting and opplionce branch - circuit panelboords. 1.2 QUALITY ASSURANCE A. Electrical Components, Devices, and Accessories: Listed and lobeled os defined in NFPA 70, by o qualified testing agency, and marked for intended locution and opplication. 1.3 GENERAL`' REQUIREMENTS FOR PANELBOARDS A. Enclosures: Flush- and surfoce- mounted cobinets. 1. Rated environmental conditions of installed location. 0. Indoor Dry and Clean Locutions: NEMA 250, Type 1. b. Outdoor Locotions: NEMA 250, Type 3R. 2. Front: Secured to box with concealed trim clomps. For surface- mounted fronts, match box dimensions; for flush - mounted fronts. overlop box. 3. Directory Card: Inside panelboord door. mounted in tronsporent card holder. B. Phase, Neutral, and Ground Buses: Tin - plated aluminum. C. Ponelboord Short- Circuit Current Roting: Fully roted to interrupt symmetrical short- circuit current available at terminals. 1.4 LIGHTING AND APPLIANCE BRANCH- CIRCUIT PANELBOARDS A. Manufacturers: Subject to compliance with requirements, provide products by one of the following: 1. Eaton Electrical Inc.; Cutler - Hommer Business Unit. 2. General Electric Company; GE Consumer & Industrial - Electrical Distribution. 3. Siemens Energy & Automation. Inc. 4. Square D; a brand of Schneider Electric. B. Ponelboards: NEMA PB 1, lighting and opplionce branch- circuit type. C. Mains: Circuit breoker. D. Bronch Over- current Protective Devices: Bolt -on circuit breakers, replaceable without disturbing adjacent units. Where multi -wire bronch circuits ore utilized provide multi -pole circuit breokers or monufocturer provided handle ties. E. Doors: Conceoled hinges; secured with flush Notch with tumbler lock; keyed alike. 1.5 DISCONNECTING AND OVER- CURRENT PROTECTIVE DEVICES A. Monufocturers: Subject to compliance with requirements, provide products by one of the following: 1. Eaton Electrical Inc.; Cutler- Hommer Business Unit. 2. General Electric Company; GE Consumer & Industrial - Electrical Distribution. 3. Siemens Energy & Automation, Inc. 4. Square D; o brand of Schneider Electric. B. Molded Cose Circuit Breaker (MCCB): Comply with UL 489, with interrupting capacity to meet ovoiloble foult currents. 1. Thermal- Magnetic Circuit Breakers: Inverse time- current element for low -level overloads. and instontoneous mognelic trip element for short circuits. Adjustoble mognelic trip setting for circuit- breoker frame sizes 250 A and larger. 2. GFCI Circuit Breokers: Single- and two -pole configurations with Class A ground-foult protection (6 -mA trip). 3. Ground -Foul: Equipment Protection (GFEP) Circuit Breokers: Closs B ground -fault protection (30 -mA trip). 1.6 INSTALLATION A. Install tiller plates in unused spaces. B. Flush ponelboords: Stub four 1 -inch empty conduits from panelboard into accessible ceiling space or space designated to be ceiling space in the future. Stub four 1 -inch empty conduits into raised floor spoce or below slob not on grade. C. Comply with NECA 1. 1.7 IDENTIFICATION A. Create a directory to indicate installed circuit loads and incorporating Owner's final room designolions. Obtain approval before installing. Use o computer or typewriter to create directory; handwritten directories ore not occeptoble. B. Ponelboord Nomeplotes: Lobel eoch ponelboord with o nameplate complying with requirements for identification specified in Division 26 Section "Identification for Electrical Systems." SECTION 16 2726 - WIRING DEVICES 1.1 A. SUMMARY This Section includes the following: 1. Receptacles, receptocles with integrol GFCI, and ossocioted device plates. 2. Snap: switches and wall -box dimmers. 3. Wall- switch occupancy sensors. 1.2 MANUFACTURERS A. Monufocturers' Nomes: Shortened versions (shown in parentheses) of the following manufacturers' names are used in other Port 2 articles: 1. Cooper Wiring Devices; a division of Cooper Industries, Inc. (Cooper). 2. Hubbell Incorporated; Wiring Device - Kellems (Hubbell). 3. Leviton Mfg. Company Inc. (Leviton). 4. Pass & Seymour /Legrand: Wiring Deices & Accessories (Pass & Seymour). 5. Lutron Electronics. 1.3 STRAIGHT BLADE RECEPTACLES A. Convenience Receptacles, 125 V, 20 A Comply with NEMA WD 1, NEMA WD 6 configurotion 5 -20R, and UL 498. 1.4 GFCI RECEPTACLES A. General Description: Straight blade. feed - through type. Comply with NEMA WD 1, NEMA WD 6. UL 498. and UL 943, Class A, and include indicotor light :hot is lighted when device is tripped. B. Duplex GFCI Convenience Receptacles, 125 V. 20 A 1.5 SNAP SWITCHES A. Comply with NEMA WD 1 and UL 20. B. Switches, 120/277 V, 20 k C. Dimmer switches: Use Lutron Novo To dimmers, match dimmer switch with fixture ballast. 1.6 WALL PLATES A. Single and combination types to match corresponding wiring devices. 1. Plate- Securing Screws: Metal with heod color to motch plate finish. 2. Material for Finished Spaces: Smooth, high - impact thermoplostic. 1.7 FINISHES A. Color: Wiring device catalog numbers in Section Text do not designote device color. 1. Wiring Devices and cover- plotes: block w/ block woll plotes, unless otherwise indicoled or required by NFPA 70 or device listing. Architect reserves the right to request multiple device finishes. 1.8 INSTALLATION A. Comply with NECA 1, including the mounting heights listed in thot standard, unless otherwise noted. See drawings. B. Conductors: 1. The length of free conductors of outlets for devices shoo meet provisions of NFPA 70, Article 300, without pigtails. 2. Existing Conductors: a. Cut bock and pigtail, or replace all damaged conductors. b. Pigtailing existing conductors is permitted provided the outlet box is Jorge enough. D. Receptacle Orientation: 1. Install ground pin of vertically mounted receptocles down, and on horizontally mounted the left. E. Receptacles Connections: 1. Provide pigtails in each receptocle box. Do not use feed through Tugs on receptocles. receptacles to SECTION 16 5100 - LIGHTING 1.1 SUMMARY A. Section Includes: 1. Interior lighting fixtures, lamps, and ballasts. 2. Emergency lighting units. 3. Exit signs. 4. Lighting fixture supports. 1.4 MANUFACTURERS A. Products: Subject to compliance with requirements. SECTION 16 6100 - FIRE -ALARM SYSTEM 1.1 SUMMARY A. Provide lire olorm devices in space as required by AHJ. Connect to building Fire Alarm Control Ponel required. 1.2 os SYSTEM SMOKE DETECTORS A. General Requirements for System Smoke Detectors: 1. Comply with UL 268; operating of 24 -V dc, nominal. 2. Detectors sholl be two -wire type. 3. Bose Mounting: Detector and ossociated electronic components shall be mounted in a twist -lock module thot connects to o fixed base. Provide terminols in the fixed base for connection to building wiring. 4. Self- Restoring: Detectors do not require resetting or readjustment after actuation to restore them to normal operation. 5. Integral Visual- Indicating Light: LED type indicating detector has operated. B. Duct Smoke Detectors: Photoelectric type complying with UL 268A. 1. Detector address sholl be accessible from fire-Worm control unit and sholl be able to identify the detector's location within the system and its sensitivity setting. 2. Relay Fon Shutdown: Roted to interrupt fan motor - control circuit. 1.3 NOTIFICATION APPLIANCES A. General Requirements for Notification Applionces: Connected to notification opplionce signal circuits. zoned os indicated, equipped for mounting as indicated and with screw terminals for system connections. 1. Combinotion Devices: Factory- inlegroted audible and visible devices in o single- mounting assembly, equipped for mounting os indicoled and with screw terminals for system connections. B. Horns: Electric - vibrating- polarized type, 24 -V dc; with provision for housing the operating mechanism behind o grille. Comply with UL 464. Horns shall produce o sound - pressure level of 90 dBA, measured 10 feet from the horn, using the coded signal prescribed in UL 464 test protocol. C. Visible Notification Appliances: Xenon strobe lights comply with UL 1971, with clear or nominal while poly- carbonate lens mounted on on aluminum foceplote. The word "FIRE" is engraved in minimum 1 -inch- high letters on the lens. 1. Rated Light Output: a. 15/30/75/110 cd, selectable in the field. 2. Mounting: Wall mounted unless otherwise indicated. 3. For units with guards to prevent physical damage, guards in ploce. 4. Fleshing shall be in 0 temporol pattern, synchronized with other units. 5. Strobe Leods: Factory connected to screw terminals. 6. Mounting Foceplote: Foctory finished. red. 1.4 ADDRESSABLE INTERFACE DEVICE A. Description: Microelectronic monitor module, NRTL listed for use in providing o system oddress for olorm-initioting devices for wired applications with normally open contacts. B. Integral Relay: Copoble of providing a direct signal to circuit - breaker shunt trip for power shutdown. light output ratings shall be determined with SEPARATE PERMIT REQUIRED FOR: 12 M8Chanical O cal � P bing [' as Piping "j cf Tukwila �G I' 'r DIVISION ELECTRICAL SYMBOLS SCHEDULE FLUORESCENT FIXTURE RECESSED MOUNTED CEIUNG FIRE ALARM CONTROL PM EL 1 0 FLUORESCENT axTURE SURFACE MOUNTED CEILING I FIRE ALARM STROBE 90' STRIP TYPE LIGHT FIXTURE CEIUNG 6 FIRE ALARM HORN/STROBE 90" I- -1 l --o- -I CEILING MOUNTED STRIP TYPE LIGHT FIXTURE CEIUNG 4s FIRE ALARM SPEAKER/STROBE 90" I--2-1 WALL MOUNTED STRIP TYPE UGHT FUTURE CEILING S FIRE ALARM CE1UNG HORN muss 0 ROAN D DOWN LIGHT TYPE LIGHT FIXTURE CEILING El nRE ALARM CEDING STROBE C IIJNG '0 WALL MOUNT SCONCE 8 FIRE ALARM CE41NG HORN/STROBE CEILING B--__K TRACK LIGHTING WITH HEADS SPACED AS INDICATED 0- FIRE/SMOKE DAMPER ® EXIT LIGHT FACE/DIRECTION:ARROWS AS INDICATED FIRE ALARM ADDRESSABLE MODULE t4 t-� ENT LIGHT FACE/DIRECTION ARROWS AS INDICATED [ FIRE ALARM PULL STATION 4Y UGHT FIXTURE ON EMERGENCY CIRCUIT ® FIRE ALARM SMOKE DETECTOR - PHOTOELECTRIC CEILING • EMERGENCY BUGEYE LIGHT FIXTURE (MUM t - FIRE ALARM DUCT DECTCCTOR • EMERGENCY DOWNUGHT TYPE LIGHT fTXTURE METER o $ SINGLE POLE SWITCH - LETTER INDICATES SWITCHING 48 PANEL SURFACE (BRANCH) n $2 $3 $4 DOUBLE POLE. 3 -WAY AND 4 -WAY SWITCHES 46' PANEL FLUSH (BRANCH) N $PL PILOT LIGHT SWITCH 46" T TRANSFORMER $K KEY OPERATED SWITCH 46" in PUSHBUTTON - SINGLE 113-x WALL BOX DIMMER SWITCH WITH TYPE AS INDICATED $ u TOGGLE SNATCH - MOTOR RATED TIME CLOCK 46. 0 MOTOR E CONTACTOR 0+ FUSED DISCONNECT p OCCUPANCY SENSOR CEIUNG MOUNTED CEIUNG ♦ TELEPHONE 18 :I es OCCUPANCY SENSOR WALL SWITCH BOX MOUNTED 46 TELEPHONE -WALL HUNG /"---%\ CONDUIT RUN EXPOSED 123 TELEPHONE - CABINET SIZE AS INDICATED /1.--N CONDUIT RUN IN OR BELOW FLOOR, OR UNDER GROUND (UG) COMMUNICATIONS BOARD SIZE AS INDICATED ■---14. HONE RUN v DATA OUTLET Q g 0* Go meR0 DUPLEX RECEPTACLE rip INDICATES WEATHERPROOF ss INDICATES STAINLESS STEEL FACEPLATE CP INDICATES CHILDPROOF RECEPTACLE DW INDICATES DISHWASHER GO *MATES GARBAGE DISPOSAL (SWITCHED) MICRO INDICATES MICROWAVE OVEN 18 M COMBINATION PHONE/DATA OUTLET Q SPEAKER -WALL MOUNTED 0 SPEAKER - CEILING MOUNTED [j]v VOLUME CONTROL e FOURPLEX RECEPTACLE 18 ti BUZZER 4I CEILING MOUNT DUPLEX RECEPTACLE BELL GFI RECEPTACLE 18 (l TV OUTLET - WALL MOUNTED ABOVE COUNTER RECEPTACLE O CEILING JUNCTION BOX RECESSED CEIUNG 4 ABOVE COUNTER GFI RECEPTACLE I.Q WALL RECESSED JUNCTION BOX SPECIAL PURPOSE RECEPTACLE WALL TYPE AS NOTED 18 0 FLOOR BOX WITH DEvICES INDICATED FLOOR REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. t,: rLS will require a new plan submittal G �tl may iaelude additional plan review fees. 9 J�wr•a. GENERAL NOTES 1. REFER TO ARCHITECTURAL ELEVATIONS AND REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHTING FIXTURES AND DEVICES. 2. LETTER THUS: 'A" - INDICATES TYPE OF LIGHTING FIXTURES. REFER TO LIGHTING FIXTURE TYPES AS NOTED ON THE LIGHTING FIXTURE SCHEDULE. 3. VERIFY LOCATION OF ALL FLOOR OUTLETS WITH ARCHITECT PRIOR TO ROUGH -IN. EXISTING CONCRETE FLOOR TO BE CUT AND TRENCHED AS REQUIRED. 4. DATA TELEPHONE AND TELEVISION CONDUIT SHALL BE MINIMUM 3/4 INCH UNLESS OTHERWISE NOTED ON DRAWINGS. 5. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. 6. FINAL CONNECTIONS TO EQUIPMENT SHALL BE PER MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED. 7. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A PULLWIRE OR EQUAL AND SHALL BE IDENTIFIED AT ALL JUNCTION, PULL, AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT, ORIGINATION AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT. 8.IT IS THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS TO ESTABLISH A STANDARD OF QUALITY. THE ENGINEER RESERVES THE RIGHT TO APPROVE METHODS AND MATERIALS NOT REFLECTED HEREIN. 9. CONTRACTOR SHALL REVIEW ARCHITECTURAL, STRUCTURAL, AND MECHANICAL DRAWINGS AND SHALL PROVIDE LIGHTS, SWITCHES, RECEPTACLES, TELEPHONE OUTLETS, EQUIPMENT CONNECTIONS. ETC., AND ASSOCIATED CIRCUITING IN NEW AND REMODELED AREAS, EVEN IF SUCH AREAS ARE NOT SHOWN ON ELECTRICAL DRAWINGS. LAYOUTS, FIXTURE TYPES, QUANTITIES, AND SPACING SHALL BE IN ACCORDANCE WITH SIMILAR AREAS ON THIS PROJECT. CONTRACTOR SHALL INCLUDE COSTS FOR THE ABOVE IN HIS BID. 10. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE OWNER. 11. WORK. MATERIALS AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE OF WASHINGTON, AND NATIONAL CODES AND ORDINANCES. 12. PROVIDE PERMITS AND INSPECTIONS REQUIRED. 13. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 14. VERIFY THAT EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH -IN. 15. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO OWNER. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING OR FACTORY WIRING IN EQUIPMENT PROVIDED BY THIS CONTRACTOR. 17. SYSTEMS SHALL BE COMPLETE, OPERABLE. AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC. SHALL BE CONNECTED AND OPERABLE. 18. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS. RACEWAYS IN SLAB -ON -GRADE OR BELOW GRADE SHALL BE SCHEDULE 40 PVC. TRANSITIONS FROM BELOW TO ABOVE GRADE SHALL BE WITH RIGID STEEL ELBOWS WITH PVC JACKET OR PROVIDED EQUAL PROTECTION. EMT FITTINGS SHALL BE MALLEABLE IRON OR STEEL. CONNECTORS SHALL BE INSULATED THROAT TYPE. 19. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EOUIPMENT SHALL BE WITH LIOUID - TIGHT FLEX METAL CONDUIT AND FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT. 20. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY UL OR OTHER RECOGNIZED TESTING FACILITY. 21. ELECTRICAL CONTRACTOR SHALL PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN ALL PHASES OF THE SYSTEM, REGARDLESS OF CIRCUITING INDICATED. 22. ELECTRICAL CONTRACTOR SHALL OBTAIN A COPY OF LANDLORD'S DESIGN CRITERIA, THIS GUIDE SUPERSEDES DRAWINGS AND SPECIFICATION (i.e. MANUFACTURER, ETC.). 23. ALL RECEPTACLE OUTLETS TO BE BLACK AND COVER PLATES TO BE POLISHED NICKEL UNLESS NOTED OTHERWISE. 24. MULTI -PHASE LOADS SHALL BE PROTECTED BY MULTI -POLE CIRCUIT BREAKERS HAVING COMMON TRIP AND SINGLE HANDLE. HANDLE TIES AND TROUGH CLIPS OR PINS ARE UNACCEPTABLE. 25. MULTI -WIRE BRANCH CIRCUITS SHALL . REQUIRE A MULTI -POLE BREAKER AS A MEANS TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES PER NEC 210.4(B). 26. ALL CONDUCTORS SHALL BE COPPER, TYPE 75 DEGREES C, MINIMUM SIZE 112. REMODELING 1. CIRCUIT NUMBERS SHOWN ON THESE DRAWINGS. SHALL NOT NECESSARILY CORRESPOND TO ACTUAL CIRCUIT BREAKER NUMBERS. CONTRACTOR SHALL CONNECT TO EXISTING CIRCUIT BREAKERS ABANDONED BY DEMOLITION /REMODELING. 2. WHERE AN ELECTRICAL SYSTEM IN THE SPACE IS CALLED OUT TO BE CONNECTED WITH AN EXISTING SYSTEM THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE POINT OF CONNECTION AS WELL AS THE MEANS OF CONNECTION WITH THE EXISTING SYSTEM. CONTRACTOR SHALL PROVIDE ALL NEW HARDWARE COMPONENTS REQUIRED TO INTEGRATE THE NEW DEVICES /COMPONENTS INTO THE EXISTING HEADEND OR SYSTEM CONTROL PANEL. CONTRACTOR SHALL PROVIDE ALL SYSTEM SOFTWARE UPGRADES REQUIRED TO INCORPORATE NEW COMPONENTS INTO EXISTING SYSTEM. 3. WHEREVER THE INSTALLATION OF ELECTRICAL EQUIPMENT CONFLICTS WITH EXISTING CONDITIONS NOT MENTIONED IN THE PLANS OR THE SPECIFICATIONS, THE CONTRACTOR SHALL DETERMINE A SATISFACTORY ALTERNATIVE MEANS OF INSTALLATION AND OBTAIN APPROVAL FROM THE ENGINEER BEFORE ACTUAL EOUIPMENT INSTALLATION. 4. CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY EXISTING EQUIPMENT OR CIRCUITS THAT ARE REMAINING TO BE RECONNECTED TO NEW OR EXISTING SWITCHBOARDS /PANELBOARDS. PROVIDE SWITCHES, RECEPTACLES, CONDUIT, WIRE, ETC. AS REQUIRED TO RESTORE CONTINUITY OF CIRCUIT(S). LIGHTING 1. RECESSED LIGHT FIXTURES INSTALLED IN GYP BOARD OR PLASTER CEILINGS SHALL HAVE PLASTER FRAMES INSTALLED PRIOR TO CEILING MATERIAL. 2. VERIFY TYPE OF CEILING CONSTRUCTION FOR PROPER MOUNTING OF ALL RECESSED LIGHT FIXTURES. INSTALLATION OF LIGHT FIXTURES SHALL COMPLY WITH ALL INTERNATIONAL BUILDING CODE REQUIREMENTS. 3. RECESSED LIGHTING FIXTURES INSTALLED INTO METAL SUSPENDED CEILING SYSTEMS FOR LAY -IN TILES AND PANELS SHALL BE INSTALLED AND SUPPORTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE ASTM C635 AND C636. 4. FIXTURES INSTALLED IN 'LIGHT -DUTY CEILING SYSTEMS" SHALL HAVE SEPARATE SUPPORTING MEMBERS. FIXTURES INSTALLED IN 'INTERMEDIATE -DUTY AND HEAVY -DUTY CEILING SYSTEMS" SHALL HAVE SEPARATE SUPPORTING MEMBERS WHEN THE WEIGHT OF THE FIXTURES EXCEEDS THE DEFLECTION AND ROTATION REQUIREMENTS OF ASTM C636 2.7.2,3 & 4. 5. REFER TO REFLECTED CEILING PLAN FOR EXACT LOCATION AND MOUNTING HEIGHTS OF ALL LIGHTING FIXTURES WITHIN THE ENTIRE TENANT SPACE. 6. ELECTRICAL CONTRACTOR SHALL MAKE FINAL ADJUSTMENTS OF ADJUSTABLE DOWNLIGHTS ALONG WITH "THE ART OF SHAVING" REPRESENTATIVE. 7. EMERGENCY FIXTURES AND EXIT LIGHTS SHALL BE FED VIA UNSWITCHED HOT CIRCUIT. FIRE ALARM 1. FIRE ALARM SYSTEM. CONTRACTOR SHALL PROVIDE CONDUIT FOR DEVICES, COORDINATE WITH MALL VENDOR. COMMUNICATIONS 1. BOXES FOR TELEPHONE, TV, DATA, WIRING DEVICES, ETC. SHALL BE MINIMUM TWO GANG WITH SINGLE GANG MUD RING. 2. SOUND SYSTEM. CONTRACTOR SHALL PROVIDE ALL CONDUIT, J- BOXES, AND WIRING FOR SOUND SYSTEM SPEAKERS TO AMPLIFIER LOCATION. CONDUIT SHALL BE A MINIMUM OF 3/4" UNLESS NOTED. OWNER TO FURNISH MUD -RINGS FOR SPEAKERS FOR CONTRACTOR TO INSTALL COORDINATE WITH TENANT. 3. SECURITY SYSTEM. CONTRACTOR SHALL PROVIDE ALL CONDUIT, AND J -BOXES (MINIMUM TWO -GANG) FOR A COMPLETE RACEWAY SYSTEM. CONDUIT SHALL BE A MINIMUM OF 3/4" UNLESS NOTED. SECURITY SYSTEM CONTRACTOR SHALL INSTALL SECURITY PANELS. CAMERAS, WIRE, SECURITY DEVICES, ETC. FILE COPY Permit Na I � - 03 (xZ Mew review approval is subject to errors and omIa ion •,, 3 of construction documents does not authorize t'; .J- uttion of any adopted rode or ordinance. Receipt u tipproved Field Copy and mews Is acknowledged: Bit' 6 Date: 5 -"t 2-19 r � City Of Tukwila BUILDING DIVISION REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC APR 19 2012 .Tukwila BUILDING DIVISION REC IVEL CITY OF TUKVVILA APR 18 2012 PERMIT CENTER "e01.-(14(1„ BRUCE M. CARLSON architecture • planning • interior design BRUCE M. CARLSON, ARCHITECT 219 N. 2ND ST., SUITE 301 MINNEAPOLIS, MN 55401 PHONE: (612) 338 -6677 FAX: (612) 338 -2995 E -MAIL: info@cmarch.com CONTACT: PHILIP FOSTER pfoster @cmarch.com CONSULTANTS: EMANUELSON -PODAS MECHANICAL / ELECTRICAL 10401 BREN RD. EAST MINNETONKA, MN 55343 952 - 930 -0050 SCOTT VANDER HEIDEN SEAL: MATTHEW W. FULTS SIGNATURE 03 -30 -2012 DATE ISSUED 45451 REG. NO. SOUTHCENTER MALL 632 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE: ELECTRICAL TITLE SHEET REVISIONS: NO: DATE: BY: PROJECT NO: 3292.0034 DRAWN BY: KO COPYRIGHT BRUCE M. CARLSON, AIA 2012 0 — 3/30/2012 0 K:\Projects\3292.0034 TAOS Southcenter Seattle WA \3292.0034 E1.2.dwg { A li \r- ii i! J it (Th 1 1 "C -318 A -1 A 24,26 16 f A -3 A -5 (E) GFCI f /....:...lL..__ //......_11.. ._//_..... Il._...._.., lL_. ..... /......1L.......Zl....._ // '�.. ♦. 'r 1: .,►.: A „i4. II OII L. - - - jACr -d-� A -2 gg 0 wp L -19` 19 CU EXIST 1EXIST PNL AI A -4 Sd" II ► CFO ✓ T 1- - -`�\t ' • 1 A- 11 \ `-\ \ A- 23,25 4 A -2 ©18 13 FCU EXIST r --; I .__.; A -18 A -2 -A7-14z TC - - - = , -. � _ ......_..._........- ....... 9._ .... VIA TC :s- R..sz. aaaaa..- .srazas. z r y: v�.n.^tn a r.—, > t.t.. .i M z., ELECTRICAL CONTRACTOR TO CREATE AND SUBMIT FIRE ALARM DRAWINGS TO BUILDING DEPARTMENT AS A DEFERRED SUBMITTAL. POWER AND SPECIAL SYSTEMS PLAN 1/4"-i-0" ELECTRICAL RECEPTACLES (DUPLEX & QUAD) - TO BE BLACK. DUPLEX RECEPTACLE COVERS - IR- 010CA -N -13, COLOR IS POLISHED NICKEL BY HOUSEOFANTIOUEHARDWIRE.COM. OUADPLEX RECEPTACLE COVERS - IIR- 010CA -N -14, COLOR IS POLISHED NICKEL BY HOUSEOFANTIQUEHARDWIRE.COM. CIRCUIT NUMBERS SHOWN ARE FOR REFERENCE ONLY AND ARE ONLY MEANT TO SHOW DESIGN INTENT. UTILIZE EXISTING CIRCUITS, SPARES, OR PROVIDE NEW BREAKERS AS NEEDED. CO) wool EXIST %T A -13 A-1 3 EXIST PNL A 0 d 1 1= L J C2 A -13 C2 A -13 AMINNMEr ✓> I 11 : 10' Oa69� ' A 3 *�( A -7 A-13 X17 815 0 ®O - .44 A- 15 ' iATC ®0 AA15 00 A -A 15 r - IA AI-15 H A r7\ =15- -1 A -1 I.,_;,; a �! fOOa J • .j IAO 1 78" 1 A -17 Aij t o TC 1 AA15 o P1 -A-IS J A-15 b A -6 ■- ir i- h it A -15/T \ I1 'CM"'I A-7 B 1 P1 NLO I -1-- 1A-15 s--� I - b A 151 A-1-5 0 A-15 - —O ®a 0 A 1 A -15 1 ®al VIA T 4' -0" A A- 15 •, AX7 0 LIGHTING PLAN 1/4 " =1' -0" EXIT AND EMERGENCY LIGHT FIXTURE TYPES AND LOCATIONS ARE SUBJECT TO BUILDING DEPARTMENT AND FIRE DEPARTMENT APPROVAL. 4' -0" E3) A9 VI , TC 1* CONDUIT TO ELECTRICAL. CLOSET A- 11 VIA TC KEYNOTES POWER pt PROVIDE "TYPED" PANEL DIRECTORY PER SPECIFICATIONS, DRAWINGS, AND LOADS BEING SERVED. 2O GENERAL CONTRACTOR TO INSTALLS THE LOW VOLTAGE DATA CABLING FROM THE PHONE BOARD TO THE CASH WRAP, AND THEY MUST TERMINATE THE LINES AT THE WRAP. ONE JACK FOR PHONE AND TWO FOR DATA, FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. s: PROVIDE DUPLEX RECEPTACLE FLUSH MOUNTED IN SHOW WINDOW CEILING, RECEPTACLE COLOR TO BE WHITE AND COVER -PLATE COLOR TO BE WHITE. O JUNCTION BOX FOR DATA/TELEPHONE AND POWER, COORDINATE WITH FURNITURE DRAWING. p SOUND SYSTEM AMPLIFIER, COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH ART OF SHAVING REPRESENTATIVE. VERIFY SHELF SIZE WITH OWNER. O EXISTING 2' X 4' X 4" TELEPHONE BOARD WITH DEDICATED DOUBLE DUPLEX RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND TO REMAIN. VERIFY SYSTEM GROUNDING AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE COMPANY. EXTEND 1" CONDUIT WITH PULLWIRE FROM SERVICE ENTRANCE AT DEMISING WALL TO TELEPHONE BOARD. FIELD VERIFY EXACT LOCATION. O 3/4" CONDUIT WITH WIRING TO EACH DATA AND TELEPHONE OUTLET, COORDINATE TENANT WIRING REOUIREMENTS PRIOR TO ROUGH -IN. Q JUNCTION BOXES SHALL BE RECESSED IN WALL FOR POWER, DATA & VOICE OUTLETS. ROUTE CABLES INTO CASH/WRAP (FOR EXACT LOCATION, REFER TO *FIXTURE FLOOR PLAN"). INSTALL OUTLETS WITHIN THE CABINET AS SHOWN ON CASH WRAP FIXTURE DETAIL 3/E1.2. GC TO PROVIDE AND \ INSTALL THE JACKS \ r- r \ I 1 I \ I I ■ \ L Ti I 1 I PHONE J, i i L J 11 12 13 14 15 PROVIDE RECESSED DUPLEX RECEPTACLE OUTLET, FLUSH MOUNTED HORIZONTALLY. EXACT LOCATION AND HEIGHT TO BE FIELD VERIFY AND PROVIDED BY FIXTURE VENDOR AND INSTALLED BY ELECTRICAL CONTRACTOR. FEED VIA TIME CLOCK TO CONTROL TYPE "F" LIGHT FIXTURES. COORDINATE INSTALLATION OF ALL RECEPTACLES WITH FURNITURE PLAN PRIOR TO ROUGH -IN. REFRIGERATION UNIT (REMOTE WATER CHILLER), 1.7FLA, 155W, 120V. PROVIDE BRASS FLUSH FLOOR MOUNTED RECEPTACLE OUTLET. WIREMOLD MODEL 11 881 WITH 8957T BRASS DUPLEX COVERPLATE. REFER TO ARCHITECTURAL. DRAWINGS FOR EXACT LOCATION. FCU -1: EXISTING HVAC UNIT AND ALL ASSOCIATED COMPONENTS, DISCONNECT SWITCH, DUCT DETECTORS, AND ETC. IN CEILING SPACE EXISTING TO REMAIN. SAW CUT /CORE DRILL EXISTING FLOOR (TOPPING ONLY) CONSTRUCTION FOR THE INSTALLATION OF CONDUIT IN FLOOR (WITH 208V BRANCH CIRCUIT) FOR EWH -2. COORDINATE WORK WITH LANDLORD'S REPRESENTATIVE. IF NO TOPPING, MUST CORE SLAB. EXISTING WATER HEATER TO REMAIN. r CASH DRAWER Milli Wel r � CASH DRAWER I L — — IMO F-- IMF - -I ICJC]I IC]C31 APt PRIER 16 t7 18 19 20 21 PROVIDE CONNECTION TO 208 VOLT SINGLE PHASE 8.3 KW WATER HEATER (EWH -1). VERIFY LOCATION OF WATER HEATER WITH MECHANICAL CONTRACTOR. LANDLORD SHALL FURNISH AND INSTALL FIRE ALARM JUNCTION BOX FOR CONNECTION TO TENANT'S FIRE ALARM DEVICES. FIELD VERIFY EXACT LOCATION PRIOR TO INSTALLATION. PROVIDE FIRE ALARM DEVICES AS SHOWN. MATCH LANDLORD'S MANUFACTURER AND SPECIFICATIONS. VERIFY CONNECTION POINT WITH LANDLORD'S REPRESENTATIVE. CONNECT TO LANDLORD'S FIRE ALARM SYSTEM. VERIFY ALL REQUIREMENTS WITH LANDLORD PRIOR TO INSTALLATION. CU -1: EXISTING HVAC UNIT AND ALL ASSOCIATED COMPONENTS, DISCONNECT SWITCH, AND ETC. ON ROOF EXISTING TO REMAIN. EXISTING DUCT SMOKE DETECTOR PROVIDE IN RETURN AIR DUCT TO REMAIN. COORDINATE ALL REQUIREMENT WITH LANDLORD. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL REMOTE TEST SWITCH WITH VISUAL /AUDIBLE INDICATION AT MANAGER'S DESK. TEST SWITCH TO BE AIR PRODUCTS AND CONTROLS INC. CATALOG NUMBER MSR- 100R/R OR EQUAL. COORDINATE ALL REQUIREMENT WITH LANDLORD. SURGE PROTECTOR ATTACHED TO BACK PANEL QUAD RECEPTACLE BY EC CASH WRAP ELEVATION 3 NO SCALE KEYNOTES LIGHTING Oj PROVIDE "TYPED" PANEL DIRECTORY PER SPECIFICATIONS, DRAWINGS, AND LOADS BEING SERVED. 2O ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOX WITH TOGGLE DISCONNECT SWITCH WITHIN 5 FEET OF SIGN IN CONCEALED SPACE. SIGN FURNISHED AND INSTALLED BY SIGN CONTRACTOR. FINAL CONNECTION OF SIGN BY ELECTRICAL CONTRACTOR. SEE ARCHITECTURAL PLANS FOR SIGN LOCATION TO DETERMINE CONDUIT AND ROUTING. ALL OUTLETS, BOXES, CONDUIT, ETC. SHALL BE CONCEALED FROM VIEW. COORDINATE EXACT LOCATION WITH TENANT PRIOR TO ROUGH -IN. DO NOT INSTALL UNTIL NEW STOREFRONT PERMIT IS APPROVED BY CITY. SIGN TO BE CONTROLLED BY TENANT'S TIME CLOCK AND PROVIDE LOCK OFF DEVICE ON CIRCUIT BREAKER. Q CONTRACTOR SHALL COORDINATE LIGHTING WITH MECHANICAL CONTRACTOR TO PREVENT DUCTWORK & PIPING INTERFERENCE WITHIN ENTIRE WORK AREA. O REFER TO REFLECTED CEILING PLAN FOR EXACT LOCATION AND MOUNTING HEIGHTS OF ALL LIGHTING FIXTURES WITHIN THE ENTIRE TENANT SPACE. SPEAKERS, WIRING AND ALL ASSOCIATED WITH SOUND SYSTEM IS FURNISHED AND INSTALLED BY VENDOR. GENERAL CONTRACTOR TO INSTALL CONDUIT IF REQUIRED PER LOCAL CODE. 6O INSTALL FIXTURE ABOVE TRIM. COORDINATE WITH ARCHITECTURAL ELEVATIONS. WALL MOUNTED ULTRASONIC OCCUPANCY SENSOR, USE WATT- STOPPER: 1UW -100 OR EQUAL. ALL LIGHT SWITCHES TO BE BLACK. SWITCH PLATES TO BE - RO1OCA -N -T, ROIOCA -N -2T, RO1OCA -N -3T, RO1OCA -N -4T, COLOR IS POLISHED NICKEL BY HOUSEOFANTIQUEHARDWARE.COM. EXISTING EXHAUST FAN TO REMAIN. BARBER POLE, VERIFY EXACT LOCATION WITH ARCHITECTURAL DRAWINGS. USE SLIM LINE JUNCTION BOX. REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC APR 19 2012 y o Tukwila BUILDING DIVISIC GENERAL NOTES 1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 2. ALL EXIT SIGNS AND NIGHT LIGHTS SHALL BE FED FROM BRANCH CIRCUIT NO. 30 (U.N.O.) AND CIRCUIT BREAKER SHALL HAVE "LOCKED -ON" DEVICE. 3. DISCONNECT SWITCHES SHALL BE TYPE "HD" (HEADY DUTY) BY G.E. OR LANDLORD APPROVED EQUAL 4. ALL ELECTRICAL WIRING SHALL BE INSTALLED IN CONDUIT, THE USE OF CABLE IS NOT PERMITTED. 5. EXISTING CONDUIT TO BUILDING'S TELEPHONE ROOM TO REMAIN, EXTEND TO NEW TELEPHONE BACKBOARD. 6. ELECTRICAL CONTRACTOR SHALL PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN ALL PHASES OF THE SYSTEM, REGARDLESS OF CIRCUITING INDICATED. 7. ALL WIRING SHALL BE IN RIGID OR EMT CONDUIT, FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC. MAX LENGTH 6 FEET, NO BX, ROMEX, ARMORED CABLE, ETC. ALLOWED. 8. REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, FIXTURES, SYSTEMS, CONDUIT AND WIRE, ETC. NOT BEING REUSED, DO NOT ABANDON. 9. ELECTRICAL CONTRACTOR SHALL OBTAIN A COPY OF LANDLORD'S DESIGN CRITERIA, THIS GUIDE SUPERSEDES DRAWINGS AND SPECIFICATION (i.e. MANUFACTURER, ETC.). 10. REFER TO "FIXTURE" DRAWINGS FOR EXACT LOCATION OF ELECTRICAL DEVICES PRIOR TO ROUGH -IN, COORDINATE WITH MILL WORK TRADES. 11. FIRE ALARM DEVICES ARE TO BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND ADA. 12. ALL FIRE ALARM WIRING SHALL BE IN CONDUIT OR AS ALLOWED BY NEC. 13. ELECTRICAL CONTRACTOR TO PROVIDE AUTHORITY HAVING JURISDICTION WITH FIRE ALARM SYSTEM INSTALLATION PLANS, FOR APPROVAL, PRIOR TO INSTALLATION. 14. ALL RECEPTACLE OUTLETS TO BE BLACK AND COVER PLATES TO BE POLISHED NICKEL UNLESS NOTED OTHERWISE. 15. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL FIRE ALARM DEVICES WITH THE BUILDING'S EXISTING FIRE ALARM CONTROL SYSTEM. 16. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL SECURITY SYSTEM DEVICES AND REQUIREMENTS WITH THE BUILDING'S EXISTING SECURITY SYSTEM. 17. ALL EXISTING SWITCHES AND RECEPTACLES TO BE REPLACED WITIREceivED NEW BLACK SWITCHES AND RECEPTACLES. CITY OF TUKWILA APR 18 2012 PERMIT CENTER BRUCE M. CARLSON architecture • planning • interior design BRUCE M. CARLSON, ARCHITECT 219 N. 2ND ST., SUITE 301 MINNEAPOLIS, MN 55401 PHONE: (612) 338 -6677 FAX: (612) 338 -2995 E —MAIL: info @cmarch.com CONTACT: PHILIP FOSTER pfoster @cmarch.com CONSULTANTS: EMANUELSON —PODAS MECHANICAL / ELECTRICAL 10401 BREN RD. EAST MINNETONKA, MN 55343 952 - 930 -0050 SCOTT VANDER HEIDEN SEAL: MATTHEW W. FULTS SIGNATURE 03 -30 -2012 DATE ISSUED 45451 REG. NO. SOUTHCENTER MALL 632 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE: LIGHTING AND POWER PLAN REVISIONS: NO: DATE: BY: PROJECT NO: 3292.0034 DRAWN BY: KO El .2 COPYRIGHT BRUCE M. CARLSON, ALA 2012 2012 1:54:29 PM tnystrom — 3/30/. Seattle WA \3292.0034 E1.3.dwg Southcent K: \Projects \3292.0034 TAOS LANDLORD NOTES: VERIFY ANY DEMOLITION WORK, AND ANY NEW WORK, REOUIRED BY THE LANDLORD THAT IS NOT SHOWN ON PLANS WITH LANDLORD'S DIRECTOR OR OPERATIONS. PRIOR TO BID. VERIFY ANY WORK REQUIRED TO PROTECT LANDLORD AND TENANT ARE ALARM/LIFE SAFETY SYSTEM WIRING AND DEVICES. SPRINKLER PIPING, DUCTWORK, PLUMBING. COMMUNICATION SYSTEM WIRING, ETC. DURING DEMOLITION AND NEW CONSTRUCTION WITH LANDLORD'S CONTROLS ENGINEER AND THE TENANT'S ARCHITECT PRIOR TO BID /START OR WORK. VERIFY CURRENT EDITION OF THE NATIONAL ELECTRICAL CODE AND AMENDMENTS ADOPTED BY THE MALL AND CITY PRIOR TO BID. VERIFY FIRE ALARM SYSTEM REQUIREMENTS WITH THE FIRE DEPT., THE TENANT'S ARCHITECT AND LANDLORD PRIOR TO BID. REUSE OF EXISTING DEVICES, ETC. IS SUBJECT TO APPROVAL BY THE FIRE DEPT. AND THE TENANT'S ARCHITECT. VERIFY ANY SERVICE/ MAINTENANCE /NEW WORK REQUIRED PRIOR TO BID. ALL FIRE ALARM SYSTEM /LIFE SYSTEM WIRING MUST BE INSTALLED IN METAL CONDUIT. RECOMMEND PROVIDE RED CONDUIT, JUNCTION BOX, ETC. ALL UGHTING FIXTURES. EQUIPMENT, DEVICES, ETC. SHALL BE U.L. LISTED. ALL WORK AND MATERIALS SHALL BE ACCORDANCE WITH THE LANDLORD'S MECHANICAL /ELECTRICAL DESIGN CRITERIA ALL CONTRACTORS SHALL OBTAIN A COPY FROM THE LANDLORD'S TENANT COORDINATOR OR MALL OPERATIONS MANAGER AND BECOME FAMIUAR WITH THE REQUIREMENTS CONTAINED WITH PRIOR TO BIDDING THE JOB. WHERE LANDLORD'S REOUIREMENTS CONFLICT WITH CODES OR ORDINANCES, THE STRICTEST INTERPRETATION SHALL APPLY. BASEMENT/TENANT SPACE /GARAGE BELOW. CHANNELING, MW CUTTING, ETC. OF FLOOR SLAB IS NOT ALLOWED. VERIFY THE FOLLOWING LANDLORD REQUIREMENTS WITH LANDLORD'S CONTROL BUILDING ENGINEER PRIOR TO BID, FLOOR SLAB CORING, CONDUIT ROUTING IN SPACE BELOW FLOOR SLAB PATCHING AND SEALING. MAY BE REQUIRED TO PERFORM RADAR /SONAR /X -RAY VERIFICATION SURVEY OF FLOOR SLAB - MUST PERFORM SURVEY IN AREA WITH POST - TENSIONED FLOOR SLAB. VERIFY LANDLORD APPROVED METHOD FOR ATTACHING TO BUILDING STRUCTURE WITH HANOiNG /SUPPORTING TRANSFORMERS, FIXTURES. CONDUIT AND ETC. WITH THE TENANT'S ARCHITECT AND LANDLORD PRIOR TO BID. ATTACHING TO ROOF DECK OR UPPER LEVEL FLOOR SLAB IS NOT ALLOWED. MAY BE REQUIRED TO SUBMIT DETIAL /PLAN TO LANDLORD STRUCTURAL ENGINEER FOR APPROVAL AT THE TENANT'S EXPENSE. PROVIDE ACCESS TO ANY LANDLORD AND TENANT EQUIPMENTS LOCATED ABOVE GYP BOARD CEILING MID ACCESS PANEL LOCATIONS WITH THE TENANT'S ARCHITECT, BUILDING ENGINEER AND LANDLORD PRIOR TO BD/START OR WORK. ALL SAW CUTTING /CORING OF MALI. FLOORING MUST BE COORDINATED WITH MALL ON -SITE REPRESENTATIVE PRIOR TO START OF CONSTRUCTION. X -RAYS OF PROPOSED FLOOR AREA MAY BE REQUIRED PER MALL MANAGEMENT BY A LANDLORD APPROVED LICENSED X -RAY CONTRACTOR. VERIFY WITH MALL ON -SITE REPRESENTATIVE PRIOR TO START OF CONSTRUCTION. EXISTING LANDLORD 120/208 VOLT 3 PHASE 4 WIRE DISTRIBUTION CTR EXISTING METER AND SOCKET TO REMAIN. REPORT ANY DIFFERENCE TO OWNER'S REPRESENTATIVE PRIOR TO BIDDING. EXISTING DISCONNECT SWITCH REPORTED TO BE 100 AMP, 120/208 VOLT, 3 PHASE 4 WIRE. REPORT ANY DIFFERENCE TO OWNER'S REPRESENTATIVE PRIOR TO BIDDING. LIGHT FIXTURE SCHEDULE FIXTURE DESIGNATION PANEL SCHEDULE MOUNTING PANEL: Exist A LOCATION: STOCK VOLTS: 208 Y/ 120 PH: 3 W: 4 AMPS MAIN BREAKER 100 AIC RATING: 10,000 MOUNT: SURFACE FED FROM: Landlord distribution center CIRCUIT DESCRIPTION LAMPS LOAD INA CKT BKR P CIR # P H CIR # 48 P CKT BKR LOAD KVA CIRCUIT DESCRIPTION B RECEPT CEILING RECESSED 0.36 20 1 1 A B C A B C A B C A B C A B 2 4' LINEAR FLUORESCENT CHANNEL, CHAIN HUNG AT 12' AFF WITH WIRE GUARD 1 20 0.72 RECEPTS 32 WATT T8 LINEAR FLUORESCENT 3000K, 85CRI PHILIPS#F32T8/TL830 /PLUS /ALTO RECEPT E 0.18 20 1 3 4 39 WATT PAR 30 CERAMIC METAL HALIDE, 3000K, 81 CRI PHILIPS #CDM35/PAR30UM /FU3K/ALTO 1 20 0.72 RECEPTS - REFRIGERATION UNIT NOTE 1 6 0.20 20 1 5 6 35 1 20 0.18 FLOOR RECEPT P1 EXUT /EM/NL NOTE 1 PENDANT MTD 7'-6" B.O. FIXTURE 0.21 20 1 7 8 X 1 20 0.36 SHOW WINDOW RECEPT - STOREFRONT LIGHTS NOTE 1/2 LITHONIA LRP LED 1 120/277 EL N 0.30 20 1 9 10 - 1 20 0.72 CASHWRAP RECEPT SURFACE MTD STOREFRONT SIGN NOTE 1/2 120 1.20 20 1 11 12 1 20 072 CASHWRAP RECEPT STOCK LIGHTS NOTE 1 0.46 20 1 13 14 1 20 056 CASEWORK RECEPTS. NOTE 1/2 SALES LIGHTS NOTE 1 0.97 20 1 15 16 1 20 0.56 CASEWORK RECEPTS. NOTE 1/2 BARBER POLE 0.20 20 1 17 18 1 20 0.36 SOUND SYSTEM NOTE 1 EX RTU RECEPT NOTE 1 0.18 20 1 19 20 1 20 0.36 TTB NOTE 1 EXIST WATER HEATER NOTE 1 2.00 20 1 21 22 1 20 0.20 TIMECLOCK NOTE 1 EXIST FCU NOTE 1 3.64 40 2 23 24 2 40 4.15 EWH -1 NOTE 1 - - 3.64 - - 25 26 .. I - I 4.15 - - SPACE I I 20 EXIST CU NOTE 1 SPACE 29 30 2 139 - LOAD SUMMARY: CONNECTED E.M.D. CALCULATED PHASE LOADING LIGHTING 3.54 KVA LARGEST MOTOR 7.28 KVA REMAINING MOTORS 2.97 KVA RECEPTACLES 5.58 KVA KITCHEN EQUIPMENT 0.00 KVA OTHER & MISC 10.70 KVA ELECTRIC HEATING 0.00 KVA SPARE / SPACE 0.00 KVA 4.42 KVA (125 %) 9.10 KVA (125 %) 2.97 KVA (100 %) 5.58 KVA ( 50% > 10KVA) 0.00 KVA (65 %) 10.70 KVA (100 %)_ 0.00 KVA (100 %) 0.00 KVA ( 100 %) w _CONNECTED PHASE A. 11 KVA PHASE B: 7.04 KVA PHASE C: 12 KVA q ,: NOTES: 1. PROVIDE LOCK -ON DEVICE 2. VIA TIME SWITCH TOTALS 30.07 KVA 83.47 AMPS 32.78 KVA 90.98 AMPS LANDLORD NOTES: VERIFY ANY DEMOLITION WORK, AND ANY NEW WORK, REOUIRED BY THE LANDLORD THAT IS NOT SHOWN ON PLANS WITH LANDLORD'S DIRECTOR OR OPERATIONS. PRIOR TO BID. VERIFY ANY WORK REQUIRED TO PROTECT LANDLORD AND TENANT ARE ALARM/LIFE SAFETY SYSTEM WIRING AND DEVICES. SPRINKLER PIPING, DUCTWORK, PLUMBING. COMMUNICATION SYSTEM WIRING, ETC. DURING DEMOLITION AND NEW CONSTRUCTION WITH LANDLORD'S CONTROLS ENGINEER AND THE TENANT'S ARCHITECT PRIOR TO BID /START OR WORK. VERIFY CURRENT EDITION OF THE NATIONAL ELECTRICAL CODE AND AMENDMENTS ADOPTED BY THE MALL AND CITY PRIOR TO BID. VERIFY FIRE ALARM SYSTEM REQUIREMENTS WITH THE FIRE DEPT., THE TENANT'S ARCHITECT AND LANDLORD PRIOR TO BID. REUSE OF EXISTING DEVICES, ETC. IS SUBJECT TO APPROVAL BY THE FIRE DEPT. AND THE TENANT'S ARCHITECT. VERIFY ANY SERVICE/ MAINTENANCE /NEW WORK REQUIRED PRIOR TO BID. ALL FIRE ALARM SYSTEM /LIFE SYSTEM WIRING MUST BE INSTALLED IN METAL CONDUIT. RECOMMEND PROVIDE RED CONDUIT, JUNCTION BOX, ETC. ALL UGHTING FIXTURES. EQUIPMENT, DEVICES, ETC. SHALL BE U.L. LISTED. ALL WORK AND MATERIALS SHALL BE ACCORDANCE WITH THE LANDLORD'S MECHANICAL /ELECTRICAL DESIGN CRITERIA ALL CONTRACTORS SHALL OBTAIN A COPY FROM THE LANDLORD'S TENANT COORDINATOR OR MALL OPERATIONS MANAGER AND BECOME FAMIUAR WITH THE REQUIREMENTS CONTAINED WITH PRIOR TO BIDDING THE JOB. WHERE LANDLORD'S REOUIREMENTS CONFLICT WITH CODES OR ORDINANCES, THE STRICTEST INTERPRETATION SHALL APPLY. BASEMENT/TENANT SPACE /GARAGE BELOW. CHANNELING, MW CUTTING, ETC. OF FLOOR SLAB IS NOT ALLOWED. VERIFY THE FOLLOWING LANDLORD REQUIREMENTS WITH LANDLORD'S CONTROL BUILDING ENGINEER PRIOR TO BID, FLOOR SLAB CORING, CONDUIT ROUTING IN SPACE BELOW FLOOR SLAB PATCHING AND SEALING. MAY BE REQUIRED TO PERFORM RADAR /SONAR /X -RAY VERIFICATION SURVEY OF FLOOR SLAB - MUST PERFORM SURVEY IN AREA WITH POST - TENSIONED FLOOR SLAB. VERIFY LANDLORD APPROVED METHOD FOR ATTACHING TO BUILDING STRUCTURE WITH HANOiNG /SUPPORTING TRANSFORMERS, FIXTURES. CONDUIT AND ETC. WITH THE TENANT'S ARCHITECT AND LANDLORD PRIOR TO BID. ATTACHING TO ROOF DECK OR UPPER LEVEL FLOOR SLAB IS NOT ALLOWED. MAY BE REQUIRED TO SUBMIT DETIAL /PLAN TO LANDLORD STRUCTURAL ENGINEER FOR APPROVAL AT THE TENANT'S EXPENSE. PROVIDE ACCESS TO ANY LANDLORD AND TENANT EQUIPMENTS LOCATED ABOVE GYP BOARD CEILING MID ACCESS PANEL LOCATIONS WITH THE TENANT'S ARCHITECT, BUILDING ENGINEER AND LANDLORD PRIOR TO BD/START OR WORK. ALL SAW CUTTING /CORING OF MALI. FLOORING MUST BE COORDINATED WITH MALL ON -SITE REPRESENTATIVE PRIOR TO START OF CONSTRUCTION. X -RAYS OF PROPOSED FLOOR AREA MAY BE REQUIRED PER MALL MANAGEMENT BY A LANDLORD APPROVED LICENSED X -RAY CONTRACTOR. VERIFY WITH MALL ON -SITE REPRESENTATIVE PRIOR TO START OF CONSTRUCTION. EXISTING LANDLORD 120/208 VOLT 3 PHASE 4 WIRE DISTRIBUTION CTR EXISTING METER AND SOCKET TO REMAIN. REPORT ANY DIFFERENCE TO OWNER'S REPRESENTATIVE PRIOR TO BIDDING. EXISTING DISCONNECT SWITCH REPORTED TO BE 100 AMP, 120/208 VOLT, 3 PHASE 4 WIRE. REPORT ANY DIFFERENCE TO OWNER'S REPRESENTATIVE PRIOR TO BIDDING. LIGHT FIXTURE SCHEDULE FIXTURE DESIGNATION DESCRIPTION MOUNTING TOTAL WATTAGE VOLTAGE LAMPS MANUFACTURER QUANTITY TYPE A RECESSED 2 HEAD MR16 METAL HALIDE ADJUSTABLE ACCENT LIGHT, INTEGRAL ELECTRONIC BALLAST, WHITE TRIM CEILING RECESSED 48 120 2 20 WATT MR16 CERAMIC METAL HAUDE FLOOD 30°, 3000K, 81CRI GE #CMH2OMR16 /830/FL CON -TECH RAN2016MH- X2- P -120V B 4 " DIAMETER DOWNLIGHTING, INTEGRAL ELECTRONIC BALLAST, SPECULAR CLEAR REFLECTOR CEILING RECESSED 35 120 1 35 WATT MR16 NARROW FLOOD 25° CON -TECH LVR16 -TE CTR1602 -P -CLR C2 4' LINEAR FLUORESCENT CHANNEL, CHAIN HUNG AT 12' AFF WITH WIRE GUARD CHAIN HUNG AT 12' AFF 52 120 2 32 WATT T8 LINEAR FLUORESCENT 3000K, 85CRI PHILIPS#F32T8/TL830 /PLUS /ALTO METALUX SSF- 232- UNV- WG /SSF -4FT E TRACK MOUNTED PAR2O METAL HALIDE ADJUSTABLE TRACK HEAD, INTEGRAL ELECTRONIC BALLAST, WHITE FINISH, TRACK LENGTH AS INDICATED ON DRAWING SURFACE MTD TRACK `4 120 1 39 WATT PAR 30 CERAMIC METAL HALIDE, 3000K, 81 CRI PHILIPS #CDM35/PAR30UM /FU3K/ALTO CON -TECH CTL80292039MH -P LT-2-P, LT-4-P, LT 6 P AS REQUIRED F LINEAR LED FIXTURE UNDER CABINET, FURNISHED AND INSTALLED BY FIXTURE MANUFACTURER UNDER CABINET - 120 6 LED HERA LIGHTING H RECESSED ADJUSTABLE WALL WASH, LOW VOLTAGE 4" TRIM TYPE "H" FIXTURES FURNISHED AND INSTALLED BY GENERAL CONTRACTOR, INCLUDING THE ONES IN THE BARBER SPA FIXTURE. CEILING RECESSED 35 120 1 35 WATT MR16 NARROW FLOOD 25° CON -TECH LIGHTING LVR16 -TE CTR1614 -P -CLR P1 PENDANT MOUNTED SELF - BALLASTED COMPACT FLUORESCENT DECORATIVE CYLINDER PENDANT MTD 7'-6" B.O. FIXTURE 70 120 5 14 WATT SELF BALLASTED COMPACT FLUORESCENT ,2700K,82CRI PHILLIPS #EUA SWP 14W BARBICAN ARCHITECTURAL PRODUCTS BAR- PL -M -AOS -14002 X SINGLE FACE EXIT SIGN , LED NICAD BATTERY SURFACE MTD - 120 - L.E.D. LITHONIA LRP LED 1 120/277 EL N X1 SINGLE FACE EXIT SIGN, LED NICAD BATTERY SURFACE MTD - 120 - L.E.DJ(2)6W,6V HALOGEN LITHONIA LHQM- S- W- 3- R -HO -RO W /ELA MR24 K0906 X2 UNIVERSAL MOUNTED RECESSED EMERGENCY LIGHT WITH EMERGENCY BATTERY PACK, TWO, 12WATT TUNGSTEN LAMPS, MFGR: SURFACE MTD 54 120 2 27 W TUNGSTEN LITHONIA ELM627 1. ALL LIGHTING FIXTURES, EQUIPMENT, DEVICES, ETC. SHALL BE U.L. LISTED. 2. ALL LIGHT FIXTURES, EQUIPMENT, WIRING METHODS, ETC. WITHIN A CEILING RETURN AIR PLENUM SHALL BE PLENUM RATED /APPROVED" AS REQUIRED BY BUILDING DEPARTMENT. VERIFY ANY /ALL REQUIREMENTS WITH THE BUILDING DEPARTMENT . 3. EXIT AND EMERGENCY LIGHT FIXTURE TYPES AND LOCATIONS ARE SUBJECT TO BUILDING DEPARTMENT AND FIRE DEPARTMENT APPROVAL. 4. ALL GENERAL LIGHTING IS SUPPLIED BY THE GENERAL CONTRACTOR. 5. DECORATIVE FIXTURES "P1" ARE FURNISHED BY TENANT AND INSTALLED BY GENERAL CONTRACTOR. 6. LED FIXTURE TYPE "F" ARE SUPPLIED BY FIXTURE MANUFACTURER. GENERAL CONTRACTOR TO COORDINATE ALL ELECTRICAL REQUIREMENT. LANDLORD .-LEASE LINE TENANT'S SPACE E.C. TO VISIT EXISTING SPACE AND SURVEY EXISTING CONDITIONS PRIOR TO BID. VERIFY EXISTING CONDUIT /CONDUCTORS /METERING AND ROUTING OF CONDUIT TO LANDLORD'S SPACE. REPORT ANY DISCREPANCIES TO ELECTRICAL DESIGNER. CONTACT LANDLORD'S ELECTRICAL CONTRACTOR TO GAIN ACCESS TO LANDLORD ELECTRICAL DISTRIBUTION ROOM IN ORDER TO TURN OFF SERVICE FOR EXISTING SPACE. THIS RISER DIAGRAM REPRESENTS (AS ACCURATELY AS POSSIBLE) THE EXISTING ELECTRICAL DISTRIBUTION SYSTEM. FIELD VERIFY ALL SIZES OF EQUIPMENT, CONDUCTORS, FUSES, ETC. SIZES SHOWN ON DRAWING SHALL BE CONSIDERED A MINIMUM. ANY EXISTING EQUIPMENT CONDUCTORS, FUSES, ETC. WHICH DO NOT MEET MINIMUM SHALL BE REPLACED TO MEET MINIMUM. ROOF EXISTING CONDUIT AND CONDUCTOR TO REMAIN. CEILING EXISTING PANEL "L" 120/208V 30, 4W 100 AMP M.C.B. TO REMAIN TIME CLOCK INTERMATIC 1T7401 B 7 -DAY NON- PROGRAMMABLE WITH 4 PST -NO SWITCH OR APPROVED EOUAL REVIEWED FOR NFPA COMPLIANCE APR 19 2012 City of Tukwila BUILDING DIVISION FLOOR RISER DIAGRAM 1 NO SCALE arriuu+ APR 182012 PERMIT CENTER BRUCE M. CARLSON architecture • planning • interior design BRUCE M. CARLSON, ARCHITECT 219 N. 2ND ST., SUITE 301 MINNEAPOLIS, MN 55401 PHONE: (612) 338 -6677 FAX: (612) 338 -2995 E -MAIL: infoOcmarch.com CONTACT: PHILIP FOSTER pfosterOcmarch.com CONSULTANTS: EMANUELSON -PODAS MECHANICAL / ELECTRICAL 10401 BREN RD. EAST MINNETONKA, MN 55343 952 - 930 -0050 SCOTT VANDER HEIDEN SEAL: MATTHEW W. FULTS SIGNATURE 03-30-2012 DATE ISSUED 45451 REG. NO. SOUTHCENTER MALL 632 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE: ELECTRICAL SCHEDULES AND DETAILS REVISIONS: NO: DATE: BY: PROJECT NO: 3292.0034 DRAWN BY: KO E1,3 COPYRIGHT BRUCE M. CARLSON, AIA 2012