Loading...
HomeMy WebLinkAboutPermit EL12-0500 - WESTFIELD SOUTHCENTER MALL - TCBYTCBY 1119 S OUTHCENTER MALL EL1 2-0500 City oftukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No.: 9202470010 Address: 1119 SOUTHCENTER MALL TUKW Project Name: TCBY Permit Number: EL12 -0500 Issue Date: 08/17/2012 Permit Expires On: 02/13/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: BRET RYAN Address: 16435 N SCOTTSDALE RD, #195 , SCOTTSDALE AZ, 85254 Contractor: Name: DANARD ELECTRIC INC Address: 18819 38TH AVE E , TACOMA WA 98446 Contractor License No: DANAREI136KG Phone: 480 998 -4200 Phone: (253)875 -8650 Expiration Date: 06/04/2014 DESCRIPTION OF WORK: REVISE ELECTRICAL TO MATCH NEW TENANT IMPROVEMENT LAYOUT Value of Electrical: NRES: $10,000.00 RES: $0.00 Fees Collected: Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: $330.63 2008 Date: O() % ? //� I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th erforman ce of work. I am authorized to sign and obtain this electrical permit. /-� Signature. Date: 0 p /�6�V---- Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL12 -0500 Printed: 08 -17 -2012 • PERMIT CONDITIONS • Permit No. EL12 -0500 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -0500 Printed: 08 -17 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://lAv■w.TtikwilaWA go' • . - . Date Application Accepted Date Application Expires: • fFor.•officluse:only). • • ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: CON'I'ACT PERSql‘t ....; perntee'eiving all project -cc...nuniMic.4ti.§ri-t"?::; :. "..::S--?5,:i"...`40,?i;;;;,:i".:"'.: Name: FecT_ (241 CL--- Name: ., . 1C— Z.v._.) 172c U.AoN.5 J-- Address: i City: State: Le/A Lute ece, CON'I'ACT PERSql‘t ....; perntee'eiving all project -cc...nuniMic.4ti.§ri-t"?::; :. "..::S--?5,:i"...`40,?i;;;;,:i".:"'.: Name: FecT_ (241 CL--- Address: City: •-coirltleste.,_. StateA Zip4eL,,,s74 Phone: eo _ qyg,420n Fax: Email: Foje-r, .ri.,at. .cox4 King Co Assessor's Tax No.: Suite Number: /1"6"11424loor: New Tenant: /14 Yes D ..No '''tar.i:.Ki.k.At Olittaftigi IN PQR,14.400'4';: A'f< '- Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ ACCP 7Z it44TrAA- u6k) rea/'r lowact Scope of Work (please provide detailed information): Will service be altered? D Yes ik No Adding more than 50 amps? 0 Yes No Type of Use: Type of work: 0 New 0 Addition 0 Low Voltage 0 Generator Property Served by: dPuget Sound Energy 0 Seattle City Light MApplicaionsWorrns-Applications On Lina2011 Applicationaleetrical Permit Applicalion Revised 8-0-11.doo Revised: August 2011 bh Service Change 1:] Remodel Tenant Improvement 0 Fire Alarm 0 Telecommunication ED Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings..... . $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added /altered circuits) ❑ Service change with added /altered circuits $81.90 number of added circuits $l 1.55 ea ❑ Circuits added /altered without service change $54.60 (up to 5 circuits) ❑ Circuits added /altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured /mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: Date: p 6— ZS' ("C.. &Pei— Day Telephone: gam' C i8 ' q i6 City state zip H:\Appliemions \Form- Applications On LineU011 Applicaliom\Electrical Permit Application Revised 11.9- 11.docc Revised: August 2011 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.Tukwila WA .eov RECEIPT Parcel No.: 9202470010 Permit Number: EL12 -0500 Address: 1119 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/30/2012 Applicant: TCBY Issue Date: Receipt No.: R12 -02162 Initials: User ID: Payee: WER 1655 Payment Amount: $264.50 Payment Date: 07/19/2012 09:01 AM Balance: $0.00 VING ZHANG TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 01919G ACCOUNT ITEM LIST: Description 264.50 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 264.50 Total: $264.50 doc: Receipt -06 Printed: 07 -19 -2012 Cit of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: httn: //www. ci. tukwila. wa. us SET RECEIPT Copy Reprinted on 05 -30 -2012 at 13:05:18 05/30/2012 RECEIPT NO: R12 -01730 Initials: JEM Payment Date: 05/30/2012 User ID: 1165 Total Payment: 1,247.04 Payee: PING RU ZHANG, ZW TRILLIONS LLC SET ID: S000001752 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D12 -183 EL12 -0500 M12 -082 PG12 -110 TOTAL: 1,063.99 66.13 61.21 55.71 1,063.99 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 1,247.04 TOTAL: 1,247.04 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 TOTAL: 66.13 1,180.91 1,247.04 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TU_ KWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206).431 -36 Permit Inspection Request Line (206) 431 -2451 �`'. Project: Iasi s i %, Type of Inspection: � � � 4111 Date Called: Special Instructions: Date Wanted: aa:mm Requester: Phone No: J,Approved per applicable codes. O Corrections required prior to approval. COMMENTS: n Inspector: n REINSPECTION FEE REQUIRED. Prior to next inspection ;fee must °be'' paid at 6300 Southcenter Blvd., Suite 100. Call to schedule'reinsipection- INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6414&) PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 R (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 x_. Project: Type of Inspection: 700/ 3 Address: j Date Called: Special Instructions% i Date Wanted:. �? f U s rm. r'm. Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. ; COMMENTS: cAi4U/5 4747 L 55 Date: D8 r1 i?/ .<41144.1\ gietc I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: 'HERMIT COORD COPIP` PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0500 PROJECT NAME: TCBY SITE ADDRESS: 1119 SOUTHCENTER MALL DATE: 05/31/12 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Buil"din Division I� Public Works n Fire Prevention Structural Planning Division UPermit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 06 /05/12 Incomplete ❑ Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route I Structural Review Required 17 No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/03/12 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 02/29/12 Contractors or Tradespeople Peter Friendly Page • Electrical Contractor A business licensed by LEI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company DANARD ELECTRIC INC 2538758650 18819 38Th Ave E Tacoma WA 98446 Pierce Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 600087726 Active DANAREI136KG Electrical Contractor 5/7/1987 6/4/2014 General Unused sociated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DANANEI336L3DANAND ELECTRIC INC Electrical Contractor General Unused 6/23/1967 5/31/1988 Archived Master Electrician INFORMATION License DOYLEKR974NF Name DOYLE, KENNETH R Status Active Business Owner Information Name Role Effective Date Expiration Date DOYLE, BONNIE L Cancel Date 01/01/1980 Bond Amount DOYLE, MICHAEL L Agent 05/07/1987 792471C DOYLE, MICHAEL L President 05/07/1987 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 DEVELOPERS SURETY E INDEM CO 792471C 05/12/2008 Until Cancelled $4,000.0004/18/2008 6 HARTFORD FIRE INS 52BSBEB9126 06/29/2007 Until Cancelled 05/12/2008 $4,000.0005/11 /2007 5 FIDELITY a DEPOSIT INS CO 400KC3812 06/29/2000 Until Cancelled 06/29/2007 $4,000.0006/29/2000 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EJONV01847 6/8/2011 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https://fortress.wa.gov/lni/bbip/Print.aspx 08/17/2012 ELECTRICAL SPECIFICATIONS 1.0 GENERAL: 1.1 ALL APPLICABLE CODES, LAWS AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS, AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR WHO SHALL INFORM THE OWNER, PRIOR TO SUBMITTING A PROPOSAL, OF ANY WORK OR MATERIAL WHICH VIOLATES ANY OF THE ABOVE LAWS AND REGULATIONS. ANY WORK DONE BY THE CONTRACTOR CAUSING SUCH VIOLATION SHALL BE CORRECTED BY THE CONTRACTOR. 1.2 INVESTIGATE EACH SPACE THROUGH WHICH EQUIPMENT MUST BE MOVED. WHERE NECESSARY, EQUIPMENT SHALL BE SHIPPED FROM MANUFACTURER IN SECTIONS OF SIZE SUITABLE FOR MOVING THROUGH AVAILABLE RESTRICTIVE SPACES. ASCERTAIN FROM BUILDING OWNER AND TENANT AT WHAT TIMES OF DAY EQUIPMENT MAY BE MOVED THROUGH ALL AREAS. 1.3 DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK. CONDUIT ROUTING IS SHOWN DIAGRAMMATICALLY AND DOES NOT SHOW ALL OFFSETS, DROPS AND RISES OF RUNS. THE CONTRACTOR SHALL ALLOW IN HIS PRICE FOR ROUTING OF CONDUIT TO AVOID OBSTRUCTIONS. COORDINATION WITH EXISTING SERVICES, INCLUDING THOSE OF OTHER TRADES, IS REQUIRED. MAINTAIN HEADROOM AND SPACE CONDITIONS. 1,4 INSTALL WORK SO AS TO BE READILY ACCESSIBLE FOR OPERATION, MAINTENANCE AND REPAIR. MINOR DEVIATIONS FROM DRAWINGS MAY BE MADE TO ACCOMPLISH THIS, BUT CHANGES WHICH INVOLVE EXTRA COST SHALL NOT BE MADE WITHOUT APPROVAL. 1.5 REMOVAL AND RELOCATION OF CERTAIN EXISTING WORK MAY BE NECESSARY FOR THE PERFORMANCE OF THE GENERAL WORK. ALL EXISTING CONDITIONS CANNOT BE COMPLETELY DETAILED ON THE DRAWINGS. THE CONTRACTOR SHALL SURVEY THE SITE AND INCLUDE ALL CHANGES AND CHARGES IN MAKING UP THE WORK PROPOSAL. . 1.6 CONNECTIONS TO EXISTING WORK: INSTALL NEW WORK AND CONNECT TO EXISTING WORK WITH MINIMUM INTERFERENCE TO EXISTING FACILITIES. TEMPORARY SHUTDOWNS OF EXISTING SERVICES SHALL BE PERFORMED AT NO ADDITIONAL CHARGES, AT TIMES NOT TO INTERFERE T FACILITIES AND ONLY WITH WRITTEN CONSENT OF WITH NORMAL OPERATION OF EXISTING FAC E D OWNER. ALARM AND EMERGENCY SYSTEMS SHALL NOT BE INTERRUPTED. MAINTAIN CONTINUOUS OPERATION OF EXISTING FACILITIES AS REQUIRED WITH NECESSARY TEMPORARY CONNECTIONS BETWEEN NEW AND EXISTING WORK. CONNECT NEW WORK TO EXISTING WORK IN NEAT AND ACCEPTABLE MANNER. RESTORE EXISTING DISTURBED WORK TO ORIGINAL CONDITION, INCLUDING MAINTENANCE OF WIRING CONTINUITY AS REQUIRED. 1.7 DISCONNECT, REMOVE AND /OR RELOCATE EXISTING MATERIAL, EQUIPMENT AND OTHER WORK AS NOTED OR REQUIRED FOR PROPER INSTALLATION OF NEW WORK. 1.8 THE CONTRACTOR SHALL KEEP ALL EQUIPMENT AND MATERIALS, AND ALL PARTS OF THE K PAVEMENTS, FREE FROM BUILDING, EXTERIOR SPACES AND ADJACENT STREETS, SIDEWALKS RE MATERIAL AND DEBRIS RESULTING FROM THE EXECUTION OF THIS WORK. EXCESS MATERIALS WILL NOT BE PERMITTED TO ACCUMULATE EITHER ON THE INTERIOR OR THE EXTERIOR. 1.9 SEAL OPENINGS THROUGH PARTITIONS, WALLS AND FLOORS WITH MINERAL WOOL OR OTHER NONCOMBUSTIBLE MATERIAL. 1.10 PROVIDE ALL NECESSARY FLASHING AND COUNTERFLASHING TO MAINTAIN THE WATERPROOFING INTEGRITY OF THE BUILDING AS REQUIRED BY THE INSTALLATION OR REMOVAL OF CONDUIT AND EQUIPMENT. PROVIDE EQUIPMENT CURBS AS REQUIRED. 1.11 ALL EXISTING MATERIAL, EQUIPMENT AND CONSTRUCTION DEBRIS TO BE REMOVED UNDER THIS CONTRACT SHALL BECOME THE PROPERTY OF THE CONTRACTOR WITH THE EXCEPTION OF SPECIFIC EQUIPMENT AND APPARATUS REQUESTED BY THE BUILDING REPRESENTATIVE, ARCHITECT OR AS NOTED TO BE RELOCATED ON THE DRAWINGS. REMOVED EQUIPMENT SHALL BE PROPERLY DISPOSED OF BY THIS CONTRACTOR. 1.12 UNLESS OTHERWISE SPECIFICALLY NOTED OR SPECIFIED, INCLUDE ALL CUTTING AND PATCHING OF EXISTING FLOORS, WALLS, PARTITIONS AND OTHER MATERIALS IN THE EXISTING BUILDING. THE CONTRACTOR SHALL RESTORE THESE AREAS TO ORIGINAL CONDITION. 1.13 ALL MATERIAL AND EQUIPMENT SHALL BE NEW UNLESS OTHERWISE NOTED AND SHALL BE IN ACCORDANCE WITH BUILDING STANDARDS. THE CONTRACTOR IS RESPONSIBLE TO INDICATE ANY DISCREPANCIES BETWEEN THE CONTRACT DRAWINGS AND ACTUAL FIELD CONDITIONS PRIOR TO SUBMITTAL OF BID. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS SHALL NOT BE MADE FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN DURING SUCH AN EXAMINATION. THE ON-SITE INSPECTION SHALL VERIFY EXISTING CONDUIT (SIZES, CLEARANCES, ETC) AND CONDITIONS. 1.14 INSURANCE: IN ACCORDANCE WITH BUILDING REQUIREMENTS AND SHALL INCLUDE A HOLD HARMLESS CLAUSE FOR OWNER AND ENGINEER. 1.15 THE FINAL ACCEPTANCE SHALL BE MADE AFTER THE CONTRACTOR HAS ADJUSTED HIS, EQUIPMENT, TESTED THE VARIOUS SYSTEMS, DEMONSTRATED THAT IT FULFILLS THE REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS AND HAS FURNISHED ALL THE REQUIRED CERTIFICATES OF INSPECTION AND APPROVAL. 2.0 SCOPE OF WORK . O LABOR, MATERIALS, EQUIPMENT, SERVICES 2.1 SCOPE OF WORK SHALL CONSIST OF PROVIDING LAB R, M T AND FEES NECESSARY FOR COMPLETE AND SAFE INSTALLATION IN CONFORMITY WITH THE NATIONAL ELECTRICAL CODE (NEC) AND ALL OTHER APPLICABLE INDUSTRY, NATIONAL AND LOCAL CODES AND AUTHORITIES HAVING JURISDICTION, AS INDICATED ON DRAWINGS AND HEREIN SPECIFIED. 22 THE DRAWINGS AND THE SPECIFICATIONS SHALL BE CONSIDERED ADDITIONAL TO ARCHITECT AND MECHANICAL ENGINEERS SPECIFICATIONS. ANY DISCREPANCY OR CONTRADICTION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. 2.3 ARCHITECTS GENERAL REQUIREMENTS ARE PART OF THIS CONTRACT AND THEY SHALL BE APPLIED BY THE GENERAL CONTRACTOR AND SUBCONTRACTORS (ELECTRICAL,ETC..). 2.4 ALL ELECTRICAL WORK TO BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL (NEC) CODE. 2.5 GENERAL CONTRACTOR SHALL VISIT THE JOB SITE IN ORDER TO FAMILIARIZE HIMSELF WITH CONDITIONS TIAT CAN AFFECT HIS WORK IN ANY MANNER. (MEASUREMENTS - PARTICULAR CONDITIONS, ETC...) NO EXTRA COST DUE TO THE IGNORANCE OF LOCAL CONDITIONS WILL BE ACCEPTED BY.THE TENANT. 2.6 GENERAL CONTRACTOR SHALL MAKE ALL NECESSARY CHECKING AND ADJUSTMENTS TO COMPLY WITH THE INTENT OF SPECIFICATIONS. 2.7 THE DRAWINGS SHOW THE APPROXIMATE LOCATION OF THE EQUIPMENT. EACH SUBCONTRACTOR SHALL VERIFY THESE LOCATIONS BEFORE INSTALLATION. 2.8 GENERAL CONTRACTOR'S TENDER SHALL INCLUDE THE COST OF ALL NECESSARY PERMITS AND CERTIFICATES, ALL DRAWINGS APPROVAL COSTS AND ALL INSPECTION COSTS REQUIRED BY ALL AUTHORITIES HAVING JURISDICTION. 2.9 EACH SUBCONTRACTOR SHALL COMPLETE THE WORK IN EVERY DETAIL. EVEN THOUGH NOT SHOWN ON DRAWINGS OR CALLED FOR IN THIS SPECIFICATION. 2.10 THE ELECTRICAL TRADE PROVIDE ALL LABOR AND MATERIALS NECESSARY FOR A COMPLETE AND OPERATING ELECTRICAL SYSTEM AS INDICATED ON THE DRAWINGS. THE TRADE SHALL ALSO PROVIDE WHICH IS OBVIOUSLY NECESSARY OR REASONABLY IMPLIED TO COMPLETE THE WORK, 2.11 ALL RUBBISH'S AND GARBAGE SHALL BE REMOVED FROM THE JOB SITE AT THE END OF EVERY WORKDAY. AT THE CONTRACT COMPLETION, ALL TOOLS AND EQUIPMENT SHALL BE REMOVED AND THE JOB SITE SHALL BE LEFT IN A CLEAN CONDITION. 3.0 GURANTEE: 3.1 EACH SUBCONTRACTOR SHALL GUARANTEE HIS WORK AND INSTALLATION REGARDING HIS CONTRACT. THE ELECTRICAL CONTRACTOR SHALL REPAIR OR REPLACE, AT HIS OWN EXPENSE, ALL DEFECTS AND THIS DURING A TWELVE MONTHS PERIOD, STARTING AT THE PROVISIONAL ACCEPTANCE BY THE TENANT. AS LONG AS THE DEFECTS IS NOT DUE TO A BAD USE OR NORMAL WEAR. 4.0 GENERAL PROVISIONS FOR ELECTRICAL WORK: 4.1 SPECIFICATIONS ARE OF SIMPLIFIED FORM AND INCLUDE INCOMPLETE SENTENCES. WORDS OR PHRASES SUCH AS "THE CONTRACTOR SHALL,' "SHALL BE," "FURNISH; "PROVIDE," "A,' "THE," AND "ALL" HAVE BEEN OMITTED FOR BREVITY. 4.2 DEFINITIONS: 1) "PROVIDE ": TO SUPPLY, INSTALL AND CONNECT UP COMPLETE AND READY FOR SAFE AND REGULAR OPERATION THE PARTICULAR WORK REFERRED TO UNLESS SPECIFICALLY OTHERWISE NOTED. 2) INSTALL": TO ERECT, MOUNT AND CONNECT COMPLETE WITH RELATED ACCESSORIES. 3) "FURNISH" OR "SUPPLY: TO PURCHASE, PROCURE, ACQUIRE AND DELIVER COMPLETE WITH RELATED ACCESSORIES. 4) 'WORK ": LABOR, MATERIALS, EQUIPMENT, APPARATUS, CONTROLS, ACCESSORIES AND OTHER ITEMS REQUIRED FOR PROPER AND COMPLETE INSTALLATION. 5) "WIRING ": RACEWAY, FITTINGS, WIRE, BOXES AND RELATED ITEMS. 6) "CONCEALED ": EMBEDDED IN MASONRY OR OTHER CONSTRUCTION, INSTALLED IN FURRED SPACES, WITHIN DOUBLE PARTITIONS OR HUNG CEILINGS, IN TRENCHES, IN CRAWL SPACES, OR IN ENCLOSURES. 7) "EXPOSED ": NOT INSTALLED UNDERGROUND OR "CONCEALED" AS DEFINED ABOVE. 8) "SIMILAR" OR "EQUAL ": EQUAL IN MATERIALS, WEIGHT, SIZE, DESIGN AND EFFICIENCY OF SPECIFIED PRODUCT. 5.0 TEMPORARY LIGHT AND POWER: 5.1 PROVIDE TEMPORARY LIGHT AND POWER SYSTEMS AT EARLIEST POSSIBLE DATE WITHIN THE CONSTRUCTION AREAS FOR THE REQUIREMENTS OF ALL TRADES AS HEREIN DESCRIBED. EXTEND SYSTEMS TO NEW CONSTRUCTION AS SOON AS PHYSICALLY POSSIBLE. MAINTAIN SYSTEM DURING WORKING HOURS OF ALL TRADES. COST OF ENERGY WILL BE PAID FOR BY OWNER. PROVIDE ALL REQUIRED MAINTENANCE, INCLUDING LAMPS AND SOCKETS. 6.0 QUALITY ASSURANCE: 6.1 QUALITY AND GAUGE OF MATERIALS: NEW, BEST OF THEIR RESPECTIVEKINDS, FREE FROM DEFECTS AND LISTED BY UNDERWRITERS LABORATORIES, INC., OR OTHER NATIONALLY APPROVED TESTING AGENCY AND BEARING THEIR LABEL. MATERIALS AND EQUIPMENT OF SIMILAR APPLICATION SHALL BE OF SAME MANUFACTURER, EXCEPT AS NOTED.' 6.2 GUARANTEE ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED AS DEFINED IN PARAGRAPH 3.0. 6.3 PRODUCT DELIVERY, STORAGE AND HANDLING 1) MOVING OF EQUIPMENT: WHERE NECESSARY, SHIP IN CARTED SECTIONS OF SIZE TO PERMIT PASSING THROUGH AVAILABLE SPACES. 2) ACCESSIBILITY: FOR OPERATION, MAINTENANCE AND REPAIR. MINOR DEVIATIONS SHALL BE PERMITTED. CHANGES OF MAGNITUDE OR INVOLVING EXTRA COST ARE NOT PERMISSIBLE WITHOUT REVIEW. GROUP CONCEALED ELECTRICAL EQUIPMENT REQUIRING ACCESS WITH EQUIPMENT FREELY ACCESSIBLE THROUGH ACCESS DOORS. 6.4 MATERIALS 1) NAMEPLATES: PROVIDE BLACK LAMICOID SHEET WITH 314 IN. WHITE LETTERING, FASTENED WITH EPDXY CEMENT FOR EACH DISCONNECT SWITCH, CIRCUIT BREAKER, PANEL, CABINET, TRANSFORMER, ENCLOSURE, MOTOR CONTROLLER AND THE LIKE. NAMEPLATES SHALL DESCRIBE THE NAME AND NUMBER OF EACH COMPONENT. 2) CABLE TAGS: TAG EACH CONDUCTOR PASSING THROUGH SPLICE OR PULLBOX WITH A WHITE LINEN TAG, INDICATING POINT OF ORIGIN AND TERMINATION OF THE CIRCUIT. 7.0 PAINT AND FINISH: 7.1 PAINT SHALL BE THE BEST GRADE FOR ITS PURPOSE. DELIVER IN ORIGINAL SEALED CONTAINERS AND APPLY IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. COLORS SHALL BE AS SELECTED BY ARCHITECT OR ENGINEER. UTILIZE GALVANIZED IRON PRIMER ON PANEL AND PULL B OX FABRICATION. . UTILIZE HOT DIPPED GALVANIZED OR DIPPED IN ES, AFTER FABRICATI N ZINC BASED PRIMER FOR: OUTLET BOXES, JUNCTION BOXES, CONDUIT HANGERS, RODS, INSERTS AND SUPPORTS. ZINC BASED PRIMER WITH FINISH TO MATCH SURROUNDINGS SHALL BE USED FOR MARRED SURFACES OF STEEL EQUIPMENT AND RACEWAYS. A FIELD APPLIED ZINC BASED PRIME COAT SHALL BE UTILIZED FOR STEEL OR IRONWORK. 7.2 BRUSH AND CLEAN WORK PRIOR TO CONCEALING, PAINTING AND ACCEPTANCE. PAINTED EXPOSED WORK SOILED OR DAMAGED; CLEAN AND REPAIR TO MATCH ADJOINING WORK BEFORE FINAL ACCEPTANCE. REMOVE DEBRIS FROM INSIDE AND OUTSIDE OF MATERIAL AND EQUIPMENT. 7.3 FINAL LOCATIONS AND MOUNTING ORIENTATIONS OF ALL SWITCHES, RECEPTACLES AND LIGHT FIXTURES SHALL BE VERIFIED WITH ARCHITECT. 7.4 ALL ACCESS DOOR LOCATIONS SHALL BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. 8.0 LOW- VOLTAGE DISTRIBUTION EQUIPMENT: 8.1 PROVIDE COMPLETE EQUIPMENT INCLUDING: SWITCHES, FUSES, CIRCUIT BREAKERS, PANELS AND TRANSFORMERS. . 8.2 ALL EQUIPMENT SHALL CONFORM TO NEMA, ANSI AND IEEE STANDARDS. 8.3 DISCONNECT SWITCHES SHALL BE FUSED OR NONFUSED AS NOTED. VOLTAGE SHALL BE AS REQUIRED. SWITCHES SHALL BE HEAVY DUTY, EXCEPT AS NOTED, AND HORSEPOWER RATED FOR MOTOR LOADS. TOGGLE TYPE SWITCHES SHALL BE NONFUSED, LOAD BREAK, HAVING MAXIMUM RATINGS OF 20 AMP AT 600 VOLTS AND 30 AMP AT 240 VOLTS. KNIFE -BLADE TYPE SWITCHES SHALL BE LOAD BREAK, QUICK - MAKE - QUICK- BREAK, UL CLASS R UP TO 600 AMP. MAXIMUM RATING EXCEPT AS NOTED SHALL BE 800 AMP. ARC QUENCHERS SHALL BE PROVIDED. SWITCHES SHALL BE SIMILAR TO GENERAL ELECTRIC QMR. ALL SWITCH ENCLOSURES SHALL BE DEAD FRONT, NEMA TYPE 1, EXCEPT AS NOTED. 8.4 FUSES: 1) CIRCUIT 601 TO 6000 AMPERES SHALL BE PROTECTED BY FUSES SIMILAR TO CURRENT LIMITING BUSSMANN LOW -PEAK TIME -DELAY FUSES KRP-C ( AMP)SP, CLASS L LISTED BY UL WITH AN INTERRUPTING RATING OF 300,000 AMPERES RMS SYMMETRICAL. 2) CIRCUITS 0 TO 600 AMPERES SHALL BE PROTECTED BY FUSES SIMILAR TO CURRENT LIMITING BUSSMAN LOW -PEAK DUAL - ELEMENT TIME -DELAY LPN -RK ( AMP)SP (250V) /LPS -RK (AMP)SP (600V) OR LPJ ( AMP)SP (600V) (UL CLASS RK1 OR CLASS J), AND BE LISTED BY UL WITH AN INTERRUPTING RATING OF 300,000 AMPERES RMS SYMMETRICAL. 3) MOTOR CIRCUITS - ALL INDIVIDUAL MOTOR CIRCUITS WITH FULL LOAD AMPERE RATINGS (FLA) OF 480 AMPERES OR LESS SHALL BE PROTECTED BY FUSES SIMILAR TO CURRENT LIMITING BUSSMANN LOW -PEAK DUAL- ELEMENT TIME -DELAY LPN -RK ( AMP)SP (250V) 1LPS-RK (AMP)SP (600V) OR LPJ (AMP)SP (600V) (UL CLASS RK1 OR CLASS J); AND BE LISTED BY UL WITH AN INTERRUPTING RATING OF 300,000 AMPERES RMS SYMMETRICAL. 4) ALL FUSES SHALL BE PROVIDED BY SAME MANUFACTURER. 5) PROVIDE 1 SPACE MATCHING FUSE FOR EACH SET OF 3. 8.5 CIRCUIT BREAKERS: MOLDED CASE BREAKERS SHALL BE THERMAL - MAGNETIC, QUICK -MAKE- QUICK - BREAK, BOLT -ON TYPE, MANUALLY OPERATED WITH INSULATED TRIP -FREE HANDLE. MULTI -POLE TYPE BREAKERS SHALL CONTAIN INTERNAL TRIP BAR: TERMINALS SHALL BE SUITABLE FOR COPPER OR ALUMINUM CABLE. FURNISH AUXILIARY DEVICES WHERE REQUIRED FOR SHUNT-TRIPPING, OPEN AND CLOSE MOTOR OPERATOR AND ALARM INDICATION. ENCLOSURES SHALL BE DEAD FRONT, NEMA TYPE 1, EXCEPT AS NOTED. FRAMES, IC AND INTERCHANGEABLE TRIPS SHALL BE AS FOLLOWS, UNLESS OTHERWISE NOTED: 1) 120 VOLTS, 100 -AMP FRAME: 10,000 AMPS, 1 POLE. 2) 240 VOLTS, 100 AMP FRAME: 18,000 AMPS, 2 AND 3 POLES. 3) 277 VOLTS, 200 AMP FRAME: 50,000 AMPS, 2 AND 3 POLES WITH INTERCHANGEABLE TRIP. 4) 277 VOLTS, 100 -AMP FRAME 14,000 AMPS, 1 POLE. 5) 480 VOLTS, 100 -AMP FRAME: 20,000 AMPS, 2 AND 3 POLES. 8.6 DISTRIBUTION PANELS: SWITCHING UNITS SHALL BE 3 PHASE, 4 WIRE CIRCUIT - BREAKER TYPE UNLESS OTHERWISE NOTED ON PANEL SCHEDULES. BUS BARS SHALL BE HARD DRAWN COPPER, MINIMUM 98 PERCENT CONDUCTIVITY, SILVER OR TIN - PLATED JOINTS. CABINETS SHALL BE GALVANIZED SHEET STEEL BACK BOX, WITH DOOR AND TRIM AND LAPPED AND WELDED CORNERS. HARDWARE SHALL BE CHROME - PLATED WITH FLUSH LOCK/LATCH HANDLE ASSEMBLY (UP TO 48 IN. HIGH DOORS) OR VAULT HANDLE, LOCK AND 3 -POINT CATCH (LARGER THAN 48 IN. HIGH DOORS). HINGES SHALL BE SEMI- CONCEALED, 5- KNUCKLE STEEL WITH NONFERROUS PINS, 180 -DEG OPENING, LOCATED A MAXIMUM 26 IN. ON CENTERS. MINIMUM GUTTER SPACES FOR LIGHTING PANELS SHALL BE 5 -3/4 IN. SIDES, TOP AND BOTTOM. DIRECTORY HOLDER SHALL BE METAL FRAME WITH CLEAR PLASTIC, TRANSPARENT COVER. A TYPEWRITTEN LIST INDICATING FEEDER CABLE AND CONDUIT SIZE, CIRCUIT NUMBERS, OUTLETS SUPPLIED AND THEIR LOCATIONS SHALL BE PROVIDED. 8.7 TRANSFORMERS SHALL BE OPEN - VENTILATED, DRY TYPE, CLASS H INSULATION, 115 DEGREE C TEMPERATURE RISE. WINDINGS SHALL BE COPPER. PRIMARY AND SECONDARY VOLTAGES SHALL BE AS NOTED. PRIMARY TAPS (6-2 112% TAPS, 2 ABOVE AND 4 BELOW RATED VOLTAGE) SHALL BE PROVIDED. ADJUST FOR REQUIRED VOLTAGE. 8.8 BALANCE THE LOAD OVER PHASES WHEN NEW CIRCUITS ARE ADDED TO NEW OR EXISTING PANELS. PROVIDE MULTI -CABLE LUGS WHERE REQUIRED. DOUBLE LUGGING SHALL NOT BE PERMITTED. MOUNTING HEIGHT SHALL BE A MAXIMUM OF 6 FT-6 IN. FROM FLOOR TO TOP SWITCH UNIT. UPDATE DIRECTORIES ON EXISTING PANELBOARDS WHERE CIRCUITING IS CHANGED. 8.9 TESTS: OPEN AND CLOSE LOAD BREAK SWITCHING DEVICES UNDER LOAD. 9.0. RACEWAYS: 9.1 PROVIDE RACEWAYS. COMPLETE WITH BOXES, FITTINGS AND ACCESSORIES. CONDUIT OR TUBING SIZES REFERRED TO IN SPECIFICATIONS AND ON DRAWINGS ARE NOMINAL DIAMETERS. MINIMUM DIAMETER SHALL BE 3/4 IN. 9.2 MATERIALS 1) RACEWAYS: a. RIGID STEEL CONDUIT: FULL - WEIGHT PIPE, GALVANIZED, THREADED. b. ELECTROMETALLIC TUBING (EMT): THIN WALL PIPE, GALVANIZED, THREADLESS. c. FLEXIBLE STEEL CONDUIT: CONTINUOUS SINGLE STRIP, GALVANIZED. d. WIREWAYS: WIRE SHALL BE AS NOTED, MINIMUM NO. 16 GAUGE STEEL WITH GROUND CONTINUITY. FINISH SHALL BE BAKED ENAMEL. COVERS SHALL BE SCREW -ON. e: SURFACE METAL RACEWAY: SIZE AS NOTED. BASE 0.04 IN., COVER 0.25 IN. MATERIAL SHALL BE STEEL. FINISH SHALL BE BAKED ENAMEL. COVERS SHALL BE SCREW -ON. 2) FITTINGS AND ACCESSORIES: a. RIGID STEEL: NONSPLIT, THREADED, STEEL OR MALLEABLE IRON.ZINC DIE CAST NOT PERMITTED. b. ELECTROMETALLIC TUBING: COMPRESSION TYPE. GALVANIZED RIGID STEEL ELBOWS, 2 IN. OR LARGER. c. FLEXIBLE METALLIC CONDUIT: ANGLE WEDGE TYPE WITH INSULATED THROAT. d. BUSHINGS: METALLIC INSULATED TYPE. 3) BOXES: a. OUTLET BOXES: EXCEPT AS OTHERWISE REQUIRED BY CONSTRUCTION, DEVICES OR WIRING, BOXES SHALL BE STAMPED STEEL, 4 IN. SQUARE OR OCTAGON FOR FIXTURES. BOXES ABOVE CEILING SHALL BE 1 -1/2 IN, DEEP. BOXES IN CEILING OR S SLAB SHALL BE 3 IN. DEEP. BOXES IN WALL FOR FIXTURES SHALL BE 2 -3/4 IN. DEEP. BOXES IN WALL FOR RECEPTACLES AND SWITCHES SHALL BE 1 -112 IN. DEEP. FURNISH WITH RAISED COVERS MD FIXTURE STUDS WHERE REQUIRED. WITHOUT FIXTURE OR DEVICE: FURNISH BLANK COVER. OFFSET BACK -TO -BACK OUTLETS WITH MINIMUM 6 IN. SEPARATION. b. JUNCTION AND PULL BOXES: GALVANIZED SHEET STEEL WITH SCREW-ON COVERS, EXCEPT AS NOTED. FURNISH WITH INSULATED SUPPORTS FOR CABLES. LOCATIONS SHALL BE AS NOTED OR REQUIRED AND ACCESSIBLE. PROVIDE BARRIERS IN NEW AND RENOVATED BOXES BETWEEN 120/208 VOLT AND 265/460 VOLT WIRING AND BETWEEN EMERGENCY AND NORMAL WIRING. FLOOR BOXES SHALL BE SUITABLE FOR CONDUIT AND DEVICES NOTED. TELEPHONE: BUSHED HOLE. POWER: DUPLEX RECEPTACLE OR OTHER AS NOTED. INCREASE SIZE TO SUIT AS NECESSARY c. PROVIDE RACEWAYS DAILY AS HEREIN SPECIFIED, EXCEPT AS NOTED. RACEWAYS SHALL BE RUN CONCEALED, EXCEPT AS NOTED. PROVIDE RACEWAY. SUPPORT UTILIZING CEILING TRAPEZE, STRAP HANGERS, OR WALL BRACKETS. PROVIDE U -BOLTS AT EACH FLOOR LEVEL OF RISER RACEWAYS AND CONNECTED TO ACCEPTABLE SUPPORTS. PROVIDE RISER CLAMPS AT EACH FLOOR LEVEL OF RISER RACEWAYS AND RESTING ON SLAB. FOR THROUGH-THE-FLOOR SYSTEMS, UTILIZE AN ASSEMBLY SIMILAR TO HUBBELL FIRE RATED POKE - THROUGH -FLOOR BOX SYSTEM. FOR ABOVE FLOO R FITTINGS TELEPHONE SHALL BE BUSHED HOLE AND P O WER SHALL BE DUPLEX RECEPTACLE OR OTHER AS NOTED. PROVIDE SEPARATION BARRIER BETWEEN POWER AND TELEPHONE COMPARTMENTS. PROVIDE JUNCTION BOX ON UNDERSIDE OF FLOOR. PACK FITTING TO RESTORE FIRE RATING OF FLOOR. SECURE ALL RACEWAYS TO SUPPORTS WITH PIPE STRAPS OR U -BOLTS SPACING OF SUPPORTS SHALL BE A MINIMUM OF 10 FT ON CENTER FOR METALLIC RACEWAY AND AS REQUIRED FOR NO NMET ALLIC RACEW A Y. SPACING S HAL L BE 5 FT CENTER F OR WIREWAYS AND PER CODE AND AS NOTED FOR OTHERS. MOUNT SUPPORTS TO STRUCTURE MASONRY WITH TOGGLE BOLTS ON HOLLOW MASONRY; EXPANSION SHIELDS OR INSERTS IN CONCRETE AND BRICK, MACHINE SCREWS ON METAL, BEAM CLAMPS ON FRAMEWORK, WOOD SCREWS ON WOOD, AND PAN THROUGH STRAPS IN METAL DECK. NAILS, RAWL PLUGS OR WOOD PLUGS SHALL NOT BE PERMITTED. WHERE REQUIRED BY STRUCTURE, FURNISH THROUGH BOLTS AND FISHPLATES. EXPOSED RACEWAYS SHALL BE RUN PARALLEL WITH OR AT RIGHT ANGLES TO WALLS. PROVIDE CLEARANCE WITH WATER,' STEAM OR OTHER PIPING (MINIMUM 3 IN. S SEPARATION FROM STEAM AND HOT WATER PIPES, EXCEPT 1 IN. FROM PIPE COVER AT CROSSINGS AND 18 IN. FOR PARALLEL RUNS). FOR HUNG CEILING OUTLETS, RUN IN HUNG CEILING AND CONNECT TO CEILING SUPPORT CHANNELS. IN MASONRY AND POURED CONCRETE, RUN VERTICALLY ONLY. GROUNDING CONTINUITY OF INTERRUPTED METALLIC RACEWAYS WITH GROUND CONDUCTOR, AND IN FLEXIBLE CONDUIT FOR FEEDERS AND MOTOR TERMINAL CONNECTIONS. EMPTY RACEWAYS OVER 10 FT LONG: PROVIDE FISH OR PULL WIRE, GALVANIZED OR NYLON ROPE. RIGID STEEL CONDUIT SHALL BE PERMITTED FOR FEEDERS AND BRANCH CIRCUITS. PAINT MALE THREADS OF FIELD - THREADED CONDUIT WITH GRAPHITE -BASE PIPE COMPOUND AND BUTT CONDUIT ENDS. TOUCH UP MARRED SURFACES AND FIELD -CUT THREADS, CRC -COLD GALVANIZED. EMT SHALL BE PERMITTED FOR BRANCH CIRCUITS ONLY, IN DRY LOCATIONS DRY WALLS, HUNG CEILINGS, HOLLOW BLOCK WALLS AND FURRED SPACES. EMT SHALL NOT BE PERMITTED IN RAISED FLOORS. FLEXIBLE STEEL CONDUIT SHALL BE UTILIZED FOR SHORT CONNECTIONS WHERE RIGID CONDUIT IS IMPRACTICAL. FROM OUTLET BOX TO RECESSED LIGHTING FIXTURE: PROVIDE MINIMUM 4 FT AND MAXIMUM 6 FT LENGTHS. FOR FINAL CONNECTION TO MOTOR TERMINAL BOX, TRANSFORMER AND OTHER VIBRATING EQUIPMENT: PROVIDE WITH POLYVINYL SHEATHING AND GROUND CONDUCTOR. MINIMUM LENGTH: 18 IN. WITH SLACK. CONNECT GROUND CONDUCTOR TO ENCLOSURE OR RACEWAY AT EACH END, FOR EXPANSION JOINT CROSSINGS, CROSS AT RIGHT ANGLES AND ANCHOR ENDS. CUT CONDUIT ENDS SQUARE. REAM SMOOTH. PAINT MALE THREADS OF FIELD THREADED RACEWAYS WITH GRAPHITE BASE PIPE COMPOUND. DRAW UP TIGHT WITH RACEWAY COUPLING. ALL COUPLINGS SHALL BE COMPRESSION TYPE. NO SET SCREW FITTINGS. EXPANSION FITTINGS SHALL BE INSTALLED AT RIGHT ANGLES WITH CLIP JOINT CENTERED IN EXPANSION JOINT. PROVIDE A LENGTH OF RUN IN ACCORDANCE MANUFACTURER'S RECOMMENDATIONS. PRESET FITTINGS SHALL ALLOW FOR TEMPERATURE VARIATION. RACEWAYS PASSING THROUGH FIRE -RATED CONSTRUCTION: SEAL OPENING WITH FIRE SEALANT. d. ERECT WALL AND SWITCH OUTLETS IN ADVANCE OF FURRING AND FIREPROOFING. OUTLET BOXES SHALL BE SET SQUARE AND TRUE WITH BUILDING FINISH. SECURE TO BUILDING STRUCTURE BY ADJUSTABLE STRAP IRON OR GROUT IN WITH MASONRY. VERIFY OUTLET LOCATIONS IN FINISHED SPACES WITH ARCHITECTURAL DRAWINGS OF INTERIOR DETAILS AND FINISHES: PROVIDE BARRIERS BETWEEN SWITCHES C CONNECTED TO DIFFERENT PHASES FOR VOLTAGES EXCEEDING 150 VOLTS TO GROUND. e. PANEL, JUNCTION AND PULL BOXES SHALL BE LOCATED CLEAR OF OTHER TRADES. CONCEAL JUNCTION AND PULL BOXES IN FINISHED SPACES. WHERE NECESSARY, REROUTE RACEWAYS OR MAKE OTHER ARRANGEMENTS FOR CONCEALMENT. BOXES SHALL BE ACCESSIBLE. SUPPORT BOXES FROM BUILDING STRUCTURE, INDEPENDENT OF CONDUIT. PROVIDE FLOOR-TO-CEILING CHANNELS FOR MOUNTING ON DRYWALL AND LIGHTWEIGHT CONSTRUCTION. OUTLET BOXES FOR FIXTURES RECESSED IN HUNG CEILINGS SHALL BE ACCESSIBLE THROUGH OPENING CREATED BY REMOVAL OF FIXTURE. SECURE TO BLACK IRON SUPPORT. MOTOR TERMINAL BOXES: COORDINATE WITH MOTOR BRANCH CIRCUIT CONDUIT AND WIRING; ADD BOX VOLUME WHERE REQUIRED. f. FIRE SEALANTS: PROVIDE FOR RACEWAYS AND WIRE PASSING THROUGH FLOOR SLOTS, SLEEVES DR OPENINGS IN FIRE - PARTITIONS ROOMS. g. PERFORM CONTINUITY TESTS OF RESISTANCE OF FEEDER CONDUITS FROM SERVICE TO POINT OF FINAL DISTRIBUTION USING 1 CONDUCTOR RETURN. MAXIMUM RESISTANCE SHALL BE 25 OHMS. 10.0 WIRE AND CABLE: 10.1 PROVIDE WIRE AND CABLE COMPLETE WITH ACCESSORIES. SIZE REFERENCE SHALL BE AWG EXCEPT AS NOTED. 10.2 CONDUCTORS SHALL BE COPPER, ASTM STANDARD SOLID (NO. 10 AND SMALLER) OR STRANDED (NO. 8 AND LARGER). GENERAL USE CABLING SHALL BE NO. 12 MINIMUM. AT 120 VOLTS AND OVER 100 FT CIRCUIT LENGTH PROVIDE NO. 10 MINIMUM. AT 265 VOLTS AND OVER 200 FT CIRCUIT LENGTH PROVIDE NO. 10 MINIMUM. 10.3 CONTROL AND ALARM CABLING, EXCEPT AS NOTED, SHALL BE NO. 14 MINIMUM. AT 120 VOLTS AND OVER 200 FT CIRCUIT LENGTH PROVIDE NO. 12 MINIMUM. 10.4 OTHER VOLTAGES AND PHASES ADJUST CABLE SIZING AS REQUIRED TO MAINTAIN VOLTAGE DROP. INCREASE RACEWAY SIZES FOR LARGER WIRE AS REQUIRED. 10.5 INSULATION SHALL BE RUBBER AND THERMOPLASTIC MEETING ASTM AND IPCEA STANDARDS. TYPE THW OR THWN SHALL BE UTILIZED FOR FEEDERS AND BRANCH CIRCUITS EXCEPT AS NOTED. TYPE SFF -2 SHALL BE UTILIZED FOR BRANCH CIRCUITS LOCATED IN WIRING CHANNELS OF CONTINUOUS FLUORESCENT FIXTURES AND IN AMBIENT TEMPERATURES OVER 90 DEG C. FOR UNGROUNDED ISOLATED BRANCH CIRCUITS PROVIDE CROSS - LINKED POLYETHYLENE INSULATION (TYPE XHHW). 10.6 COLOR CODING SHALL BE AS FOLLOWS: 1) 120/208 VOLT SYSTEM: BLACK FOR A PHASE RED FOR B PHASE BLUE FOR C PHASE 2) 277/480 VOLT SYSTEM: BROWN FOR A PHASE ORANGE FOR B PHASE YELLOW FOR C PHASE 3) NEUTRAL WIRE SHALL UTILIZE WHITE OUTER COVERING THROUGHOUT. EQUIPMENT GROUND WIRE SHALL UTILIZE GREEN OUTER COVERING THROUGHOUT. 10.7 WHERE COLOR -CODED CABLE IS NOT AVAILABLE, CERTIFY IN WRITING AND REQUEST PERMISSION TO OVERLAP CONDUCTORS WITH 6 IN. OF COLOR TAPING IN ACCESSIBLE LOCATIONS. 10.8 PROVIDE FLAMEPROOF LINEN OR FIBER TAGS IN ACCESSIBLE LOCATIONS. FOR FEEDERS INDICATE FEEDER NUMBER, SIZE, PHASE AND POINTS OF ORIGIN AND TERMINATIONS. FOR CONTROL AND ALARM WIRING INDICATE TYPE (CONTROL OR ALARM), SIZE OF WIRE, AND POINTS OF ORIGIN AND TERMINATIONS. 10.9 TERMINATIONS, SPLICES AND TAPS UNDER 600 VOLTS: COPPER CONDUCTORS NO. 10 AND SMALLER SHALL UTILIZE COMPRESSION -TYPE OF TWIST -ON SPRING - LOADED CONNECTORS AND CLEAR NYLON - INSULATED COVERING. COPPER CONDUCTORS NO. 8 AND LARGER SHALL UTILIZE MECHANICAL BOLTED PRESSURE OR HYDRAULIC COMPRESSION TYPE USING MANUFACTURER'S RECOMMENDED TOOLING. CABLE LUGS AND CONNECTORS SHALL UTILIZE COMPRESSION TYPE OF SAME METAL AS. CONDUCTOR. PROVIDE TO MATCH CABLE, WITH MARKING INDICATING SIZE AND TYPE. COPPER LUG CONNECTIONS TO BUS BARS: USE ANTISEIZE COMPOUND ON TANG. 10.0 WIRE AND CABLE CONTINUED 10.10 NOT MORE THAN 3 LIGHTING OR CONVENIENCE OUTLET CIRCUITS SHALL BE INSTALLED IN ONE CONDUIT UNLESS OTHERWISE INDICATED. PULL NO THERMOPLASTIC WIRES AT TEMPERATURES LOWER THAN 32 DEG. F. PROVIDE SEPARATE RACEWAYS FOR CONDUCTORS OF 120/208 AND 277/480 VOLT SYSTEMS, EXCEPT 480 VOLT MOTOR BRANCH CIRCUIT WIRING AND RELATED 120 VOLT CONTROL WIRING. THERMOPLASTIC WIRES SHALL NOT BE INSTALLED IN COMPUTER AREA RAISED FLOORS. 10.11 LEAVE WIRES WITH SUFFICIENT SLACK TO PERMIT MAKING FINAL CONNECTIONS. 10.12 PERFORM CONTINUITY AND INSULATION TESTS. MEGGER TEST 100 PERCENT OF FEEDERS, 10 PERCENT OF BRANCH CIRCUITS AND ALL MOTOR BRANCH CIRCUITS OVER 25 HP. 10.13 PERFORM TESTS PRIOR TO CONNECTING EQUIPMENT AND IN PRESENCE OF AUTHORIZED REPRESENTATIVES. SUBMIT WRITTEN REPORT OF RESULTS. CORRECT OR REPLACE CABLE TESTING BELOW MANUFACTURER'S STANDARDS. . 10.14 ALL LOW VOLTAGE WIRING ABOVE CEILING, SHALL BE PLENUM RATED OR IN CONDUIT AS REQUIRED BY LOCAL JURISDICTION HAVING AUTHORITY. 11.0 DEVICES: 11.1 PROVIDE COMPLETE MATERIAL AND ACCESSORIES AS NOTED. 11.2 LOCAL WALL SWITCHES SHALL BE SPECIFICATION GRADE, TOGGLE, QUIET TYPE, RATED 20 AMP, 120/277 VOLT, AC. 11.3 INSERTION RECEPTACLES SHALL BE SPECIFICATION GRADE DUPLEX CONVENIENCE 125 VOLTS, 2 POLE, 3 WIRE, U GROUND SLOT. GROUNDED, EXCEPT AS NOTED. MEETING NEMA STANDARDS, PUBLICATION WD-1 -1971. 1) SINGLE, EXCEPT AS NOTED: a. 20 AMP STRAIGHT BLADE, b. 125 VOLT, LT, 2 POLE, P ! 3 WIRE, GROUNDED. 2) SPECIAL USE: NONINTERCHANGEABLE TYPES AND RATINGS. 3) CLOCKS: SINGLE REGRESSED RECEPTACLE, 5 WIRE 4) GROUND FAULT INTERRUPTER RECEPTACLES: a. FEED -THRU TYPE. 11.4 DEVICE PLATES: SEE ARCHITECT FOR TYPE. FOR RECEPTACLES WITH OTHER THAN 120 VOLT, INSCRIBED VOLTAGE AVAILABLE. 11.5 COLORS: COORDINATE COLORS WITH ARCHITECT. 11.6 MOUNTING ORIENTATION OF RECEPTACLES (HORIZONTAL OR VERTICAL) COORDINATE WITH • ARCHITECT. 12.0 LIGHTING FIXTURES: 12.1 PROVIDE FIXTURES ("LUMINARES "), COMPONENTS AND LAMPS. FIXTURES SHALL BE COMPLETELY FACTORY ASSEMBLED, WIRED AND EQUIPPED WITH ALL NECESSARY SOCKETS, BALLASTS, SUPPORTING HARDWARE AND ACCESSORIES. REFER TO DRAWINGS FOR INDIVIDUAL FIXTURE DESCRIPTIONS. 12.2 FIXTURE CATALOG NUMBERS USED TO ILLUSTRATE EQUIPMENT TYPE DO NOT NECESSARILY DENOTE REQUIRED MOUNTING EQUIPMENT OR ACCESSORIES. PROVIDE ACCESSORIES TO SUIT. 12.3 BALLAST: CLASS P, HIGH POWER FACTOR, LOWEST AVAILABLE NEMA RATED NOISE LEVEL, ET1 AND CBM APPROVED. ENERGY SAVING TYPE. TRIGGER START FOR 24 -INCH LAMPS AND RAPID START FOR 48 -INCH. TWO LAMP BALLASTS; NO THREE LAMP BALLASTS. BALLASTS SHALL BE • ADVANCE MAGNETEK, UNIVERSAL OR EQUAL. 13.0 TELEPHONE CONDUIT SYSTEM: 13.1 PROVIDE COMPLETE SYSTEM OF: EMPTY CONDUIT, PULL BOXES, OUTLETS, SLEEVES AND FISHWIRES. 13.2 EQUIPMENT SHALL CONFORM TO REQUIREMENTS OF TELEPHONE COMPANY. 13.3 OUTLETS SHALL BE: 1) WALL: 4 IN, SQUARE WITH BUSHED COVER PLATE. 2) FLOOR: CAST IRON WITH LOW TENSION FITTING. 13.4 PROVIDE FISHWIRES, IN RACEWAYS OVER 10 FT LONG. 13.5 CONDUIT SHALL BE 3/4 IN. MINIMUM. FURNISH EMPTY CONDUIT FROM OUTLET TO NEAREST ACCESSIBLE HUNG CEILING. SEPARATE PERMIT REQUIRED FOR: la Mechanical 0 Electrical Plumbing. Gas Piping City of Tukwila B.UI ..D'NG DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division_ NOTE: Revisions Will require a new pl^n s+..i? mitt ^t and may include additional pan r ^,F;, REVIEWED .i-Ort COMPLIANCE WITH NFPA 70 - NEC JUN 1 1 2012 City of ' iia BUILDING ► ISION FILE COPY Permit No., irl Plan review approval is pct to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field and melons is acknowledged: B Date: . /I /1a- City Of Tukwila BUILDING DIVISION c�rrn MAY 312012 CAW *6q 2 -0500 TCB12007 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building 'seizure, and /or monetary liability. a) 00 V ` L M N W e- Alia �. M = • via 0 ma 51 In vi � V rd GI 51 U a 0 6 0 n w O • Z t.) Li. W oc G W J W :11: 0 c,c4R g 10 d _I L _!._ .>, f0 1 it a' .' a5 SP I SS .fl C§ 8 0 co o 4 N "I Z 0) co 0 It T- I- Imm ) J "Q to E (I� E .- CL z O immolimmimulmmummummommilm DATE: 5 -I8 -2012 SHEET: SCALE: DRAWN BY: PROJECT No.: TGI51 ?{00 -i E1.0 LIGHT FIXTURE SCHEDULE MARK SYMBOL MANUFACTURER CATALOG NUMBER FIXTURE DESCRIPTION VOLT LAMP DESCRIPTION REMARKS A3 TEXAS FLUORESCENTS 131A125332MY 2x4 LAY -IN FLUORESCENT 120 (3)F32T5 WITH .125 ACRYLIC DIFFUSER L.........---- / {{{/// EF ASE �' TEXAS FLUORESCENTS 131AI25352E12O -EM 2x4 LAY -IN FLUORESCENT 120 (3)F32T6 SAME FIXTURE AS "A3" ABOVE WITH MINIMUM 010 MIN EMERGENCY BATTERY BACK -UP B w n„ TGBY APPROVED MANUFACTURER CUSTOM MD PENDANT MOUNTED BARREL LIGHT 120. (3) 60W INCANDESCENT MOUNT BOTTOM OF SHADE AT 9' -O" AFF 02 Q INTENSE IFV626E -1200 IG600G 6" RECESSED DOWNLI 'HT 120 (I) 26W GFL. 4 -PIN WITH CLEAR REFLECTOR AND WHITE TRIM RING WITH BAR HANGERS D2E (, INTENSE IFV626E -1200 EMIC600C 6.° RECESSED DOWNLIGHT 120 (1) 26W GFL 4 -PIN SAME FIXTURE AS "D2" ABOVE WITH MINIMUM 410 MIN EMERGENCY BATTERY BACK -UP D3 WALL MOUNTED SPEAKER HORNET R -212- LED -E -WT- 120 -5P -SP -WT -3000 DUAL HEAD RECESSED ADJUSTABLE LED 120 (2) 12104 LED LEA DRIVER 0 0 COI�PLIANC NBC CEILING MOUNTED TELEVISION OUTLET NFPA70 D4 U.N.O. JUNG MOIL- 3K -FL -WH RECESSED DOWNLIGHT 3" MINI ADJUSTABLE 12 SW MRI6 LED REMOTE POWER SUPPLY REQUIRED -- -- INTENSE ITM -12 -100 REMOTE 12V POWER SUPPLY -- -- 100VA - 120/12V L LED POWER 4 . PHILIPS ADVANCE -- HIGH POWER LED LIGHT BAR 12 LED SYSTEM WATTS: qb 446- ARP -25, (4) AL-H1540 LT1148 "M4F -2, (6) AL-1-1540 ADJ. (3) AL- H13446 W BRACKET, (2) AL -H840 LTW 12" FE -2P, (2) PHILLIPS PS- LEDINTA0024V41F0 REMOTE POWER SUPPLY TO BE LOCATED WITHIN 12' -0" P s3 GONTEGH GR24166 -S TRACK 24 -- LOW VOLTAGE FLEXIBLE GABLE TRACK, MOUNT RAIL AT I' -6" AFF: 6' L -TRACK WITH END GAPS, CRS2443 -9 GABLE CEILING CONNECTION, CRS- MAGQR -S QUICK RELEASE ADAPTER, GR52a5 -5 TRACK INTERCONNECTION ADAPTER, CR5293 -5 POWER FEED, CRS- FEEDWIRE -6M -S 6M LEAD WIRE, LVT- 150 -24 I5OVA, 24V REMOTE TRANSFORMER f ---- -i PI _ TGBY APPROVED MANUFACTURER • CUSTOM TBD GLASS SHADE MONO -POINT PENDANT 120 60W INCANDESCENT MOUNT BOTTOM OF SHADE AT 5' -6" AFF P2 GONTEGH GR5691QR -S TRACK HERD 24 IOW MRI6 LED SOLID SYMBOL LIGHT I5 DIRECTED TOWARD MESSAGE WALL; OPEN SYMBOL LIGHT IS DIRECTED. TOWARD TOPPING BAR GT X! -� _ EXITRONIX 400U-100-15L PIE CAST EXIT SIGN MULTI LED PROVIDE FACES AND MOUNTING AS REQUIRED. MINIMUM 90 MIN BATTERY BACK -UP, BLACK FINISH (VERIFY COLOR 4 QUANTITY REQ'D) X2 EXITRONIX 400U-AS-IN DIE CAST EXIT SIGN MULTI LED PROVIDE FACES AND MOUNTING AS REQUIRED. MINIMUM 10 MIN BATTERY BACK -UP, BLACK FINISH (VERIFY COLOR $ QUANTITY REQ'D) Z O DUAL LITE PGA EMERGENCY LIGHT MULTI MULTI LED REFER TO ARCHITECTURAL PLANS FOR FINISHING NOTE: I. FIXTURES INDICATED WITH "NL" ARE TO BE CONNECTED TO A LOCAL CIRCUIT AHEAD OF SWITCH (HOT) FOR CONTINUOUS OPERATION - NIGHT LIGHTING 2: ALL FIXTURES QUANTITIES, LOCATIONS AND MODEL NUMBERS SHALL BE COORDINATED WITH THE ARCHITECTURAL PLANS PRIOR TO ORDERING. DO NOT ORDER FROM THESE PLANS. 3. COMPLY WITH NEC 41013.6 FOR DISCOUNTING MEANS WITH APPLICABLE FOR FLUORESCENT LUMINARIES. 4. LUMINARIES TO SE SECURELY FASTENED TO FRAMING MEMBERS OF CEILING BY MECHANICAL MEANS PER NEC. 410.160. GENERAL NOTES I. CONTRACTOR TO FAMILIARIZE HIMSELF WITH THE SITE AND VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION AND ADJUST FOR ACTUAL FIELD CONDITIONS AT NO EXPENSE TO OWNER. REPORT TO THE ARCHITECT AND OR ENGINEER ANY DISCREPANCIES WITH THE PLANS AND EXISTING CONDITIONS. 2. "NL" DESIGNATION INDICATES FIXTURE TO BE NIGHT LIGHT, CIRCUITED HOT FOR CONTINUOUS OPERATION. 3. CONDUIT LAYOUTS ON THE PLANS ARE DIAGRAMMATIC, NOT INDICATING THE ROUTING REQUIRED. THE CONTRACTOR SHALL ROUTE CONDUITS AS REQUIRED BY THE CONDITIONS OF INSTALLATION. 4. ALL EQUIPMENT PROVIDED BY THE ELECTRICAL CONTRACTOR SHALL BE LISTED AND LABELED BY A NATIONALLY RECOGNIZED TESTING AGENCY, ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. 5. MINIMUM WIRE SIZE SHALL BE #12 AWG CU. MINIMUM CONDUIT SIZE SHALL BE 3/4" UNLESS NOTED OTHERWISE. 6. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO ORDERING OR INSTALLING ANY EQUIPMENT, TO VERIFY ELECTRICAL REQUIREMENTS OF EQUIPMENT PROVIDED BY ALL OTHER TRADES ARE PROVIDED FOR IN THE ELECTRICAL DESIGN. THE CONTRACTOR WILL NOT BE COMPENSATED FOR COSTS ASSOCIATED WITH CHANGING THE ELECTRICAL SYSTEMS TO MATCH UTILIZATION EQUIPMENT, EVEN IF THE ELECTRICAL WORK IS INSTALLED PER THE DRAWINGS. 1. UNLESS SPECIFICALLY NOTED OTHERWISE, SYSTEMS PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR SHALL BE COMPLETE AND FULLY FUNCTIONING AFTER INSTALLATION. COMPONENTS NOT SHOWN, BUT REQUIRED' FOR THE PROPER OPERATION OF THE EQUIPMENT OR SYSTEM, SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE PROJECT. 5. PRIOR TO TRENCHING IN ANY AREA, THE CONTRACTOR SHALL. CONTACT ELECTRICAL, COMMUNICATIONS, GABLE TV, GAS AND WATER UTILITY PROVIDERS AND HAVE ALL UTILITIES IN THE AREA IDENTIFIED. IN ADDITION, THE CONTRACTOR SHALL OBTAIN THE SERVICES OF A SUB - CONTRACTOR SPECIALIZING IN THE. LOCATION OF UNDERGROUND STRUCTURES TO IDENTIFY. ANY OBSTACLES IN THE PATH OF TRENCHING (PRIOR TO COMMENCING WORK). DAMAGE TO UNDERGROUND STRUCTURES SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE PROJECT. al. WHERE THE PLANS INDICATE A LIGHT FIXTURE 15 TO BE PROVIDED WITH SPECIAL FEATURES /SWITCHING (DIMMING,. EMERGENCY, THREE LEVEL, ETC) THE CONTRACTOR SHALL PROVIDE THE FIXTURES WITH THE APPROPRIATE BALLASTING TO ACCOMMODATE THE SPECIAL FEATURE. THE CONTRACTOR SHALL PROVIDE THE FIXTURE AS INDICATED IN THE LIGHT FIXTURE .SCHEDULE, WITH MODIFICATIONS AS REQUIRED, PER PLAN NOTES. . — NAMEPLATE r— PANELBOARD SELF TAPPING (TYPICAL.) SCREWS ENGRAVED LAMAGOID, 5/32 INCH LETTERS ® PANEL " ?!' PANELBOARD 3IN. DESIGNATION STANDARD COLORS: L NORMAL POWER - BLACK BACKGROUND, WHITE LETTERS 2. EMERGENCY POWER - RED BACKGROUND, WHITE LETTERING NAMEPLATES ARE REQUIRED ON ALL PANELBOARDS, STARTERS AND DISCONNECT SWITCHES. PANELBOARD NAMEPLATE DETAIL SCALE: N.T.S. 10. WHERE PORTIONS OF A GABLE RACEWAY OR SLEEVE ARE KNOWN TO BE SUBJECTED TO DIFFERENT TEMPERATURES AND WHERE CONDENSATION IS KNOWN TO BE AN ISSUE, AS IN GOLD STORAGE AREAS OF BUILDINGS OR WHERE PASSING PROM THE. INTERIOR TO THE EXTERIOR OF A BUILDING, THE RACEWAY OR SLEEVE SHALL BE FILLED WITH AN APPROVED MATERIAL TO PREVENT THE CIRCULATION OF WARM AIR TO COLDER SECTION OF THE RACEWAY OR SLEEVE PER NEC 300.1 II. WORK IN THE KITCHEN OR FOOD PREPARATION AREAS SHALL COMPLY WITH THE FOLLOWING : • FINAL CONNECTION TO ALL KITCHEN EQUIPMENT SHALL BE NtADE WITH LIQUID TIGHT FLEXIBLE METAL CONDUIT, UNLESS A CORD AND PLUG CONNECTION. IS PROVIDED BY THE MANUFACTURER. • - THE ELECTRICAL CONTRACTOR SHALL MAKE FINAL ELEGTRIGAL CONNECTIONS TO ALL KITCHEN FOOD SERVICE AND RELATED EQUIPMENT. c - THE ELECTRICAL CONTRACTOR SHALL. VERIFY ROUGH -IN REQUIREMENTS, LOCATIONS MOUNTING HEIGHTS, VOLTAGE, PHASE, AMPS, HP AND KW FOR ALL FOOD SERVICE EQUIPMENT PRIOR TO ROUGH -IN. d - PROVIDE CONDUIT SEALS FOR ALL CONDUITS ENTERING OR LEAVING WALK -IN BOXES. e - THE ELECTRICAL CONTRACTOR SHALL VERIFY THE ROUGH -IN REQUIREMENTS, LOCATIONS, ORIENTATIONS, VOLTAGE, PHASE, HP AND KW FOR ALL HVAG AND PLUMBING EQUIPMENT PRIOR TO ROUGH -IN. - THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL DISCONNECT SWITCHES, INTERLOCKS, CONDUIT AND WIRING AS SPECIFICALLY OUTLINED WITH -IN THE KITCHEN EQUIPMENT DRAWINGS. 9 - PROVIDE AND INSTALL ALL CONNECTIONS INCLUDING POWER AND CONTROL WIRING TO ALL WALK N BOXES AND TO THE REMOTE COMPRESSORS. REFER TO THE MANUFACTURER SPECIFICATIONS FOR SPECIFIC REQUIREMENTS. h - ALL RECEPTACLES MOUNTED IN KITCHENS, TOILET ROOMS, WITHIN 6 FEET OP SINKS /BASINS AND OUTDOORS SHALL BE GFGI TYPE. 1 - ALL EXTERIOR DEVICES SHALL BE WEATHERPROOF. j - FOR EACH EQUIPMENT ITEM NOT PROVIDED WITH CORD AND PLUG CONNECTION THE CONTRACTOR SHALL. VERIFY THE EQUIPMENT CONTAINS AN INTEGRAL UNIT SWITCH COMPLYING WITH THE NEC, ARTICLE 422 -25. IP THE EQUIPMENT HAS NO UNIT SWITCH, PROVIDE A LOCK -OAF DEVICE AT EACH BRANCH CIRCUIT BREAKER FEEDING THE EQUIPMENT. /12 SAFETY WIRE TIED . TO SAFETY WIRE SUPPORT HOLES 4 FASTENED TO BLDG. STRUCTURE. MINIMUM (2) SAFETY WIRES PER LIGHT FIXTURE PLACED AT DIAGONAL CORNERS ALL WIRES ARE TO BE TAUT WITH A MINIMUM OF 3 TIGHT TURNS AROUND SELF - TYPICAL EXPOSED T -BAR CEILING EXISTING STRUCTURE H'LTI GG21 CLIP OR EQUAL LIGHT FIXTURE SAFETY WIRE SUPPORT HOLE, TYPICAL RECESSED FIXTURE SUPPORT DETAIL SCALE: N.T.S. ELECTRICAL SYMBOLS LEGEND NOTE: NOT ALL SYMBOLS' OR ABBREVIATIONS MAY APPEAR ON PLANS. FIRE ALARM SYMBOLS LEGEND f�,�-1 MANUAL PULL STATION. VERIFY MOUNTING HEIGHT AND LOCATION WITH JURISDICTION HAVING AUTHORITY {� E WALL MOUNTED DUPLEX RECEPTACLE AT 16" A.F.F. UNLESS NOTED OTHERWISE G/B CIRCUIT BREAKER CC D DEDICATED WALL MOUNTED DUPLEX RECEPTACLE AT 16" A.F.F. UNLESS NOTED OTHERWISE ® WALL MOUNTED QUADRAPLEX RECEPTACLE AT 16" A.F.P. UNLESS NOTED OTHERWISE GE WALL MOUNTED 206V RECEPTACLE AT I6" A.F.F. UNLESS NOTED OTHERWISE E.G. FLOW SWITCH 2 CEILING MOUNTED DUPLEX RECEPTACLE EF CM ® FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE 01 WALL MOUNTED JUNCTION BOX AT 16" A.F.F. UNLESS NOTED OTHERWISE ® CEILING MOUNTED JUNCTION BOX ON NEW SEMI - RECESSED TYPE SPRINKLER TO REMAIN ©E DISCONNECT SWITCH IN NEMA ENCLOSURE - SIZE AS INDICATED ON PLANS alR, EPFUSED DISCONNECT SWITCH IN NEMA ENCLOSURE - SIZE AS INDICATED ON PLANS 11-3" WALL MOUNTED VOICE/DATA OUTLET AT 16" A.F.F. UNLESS NOTED OTHERWISE D WALL MOUNTED VOICE OUTLET AT 16" A.F.F. UNLESS NOTED OTHERWISE LIGHTING WALL MOUNTED DATA OUTLET AT 16" Arr. UNLESS NOTED OTHERWISE ® FLUSH• FLOOR MOUNTED VOICE/DATA OUTLET 0 FLUSH FLOOR MOUNTED VOICE OUTLET ® FLUSH FLOOR MOUNTED DATA OUTLET /q/ MOTOR t =`i CHIME 4 PUSH- BUTTON (>1 WALL MOUNTED SPEAKER OS CEILING MOUNTED SPEAKER 113 -1 WALL MOUNTED TELEVISION OUTLET V1E1�11E1 FOB H TENANT T.G.G. TENANT GENERAL CONTRACTOR COI�PLIANC NBC CEILING MOUNTED TELEVISION OUTLET NFPA70 W U.N.O. $ SINGLE POLE TOGGLE SWITCH 1� jN 1 1 2012 Jv y 3 -WAY TOGGLE SWITCH Tukwila $4 City of 4-WAY TOGGLE SWITCH BUILDING DJ ! !On ,.BU. - • . 05 OCCUPANCY SENSOR SWITCH 4T TIMER SWITCH j M HORSEPOWER RATED MANUAL MOTOR STARTER 17 DIMMER SWITCH PHOTOCELL 22 WALL /CEILING MOUNTED OCCUPANCY SENSOR s3 * SECURITY CAMERA © SURFACE MOUNTED 120/203V PANEL - 3' -O" CLEARANCE IN FRONT OF PANEL PER N.E.G. RECESSED MOUNTED 120/203V PANEL - 3' -O" CLEARANCE IN FRONT OF PANEL PER N.E.G. _ SURFACE MOUNTED 211/460V PANEL - 3' -0" CLEARANCE IN FRONT OF PANEL PER N.E.G. RECESSED MOUNTED 211/460V PANEL - 3' -O" CLEARANCE IN FRONT OF PANEL PER N.E.G. MAIN SWITCHBOARD OR DISTRIBUTION PANEL - VERIFY VOLTAGE ON RISER DIAGRAM 07 Ag, PHONE BOARD C/T CABINET GT i7 ELECTRIC METER - VERIFY REQUIREMENTS WITH LOCAL UTILITY STEP DOWN TRANSFORMER - SIZE AS INDICATED ON PLANS T GROUND •- -Ni• �--N, INDICATES HOMERUN �. INDICATES CIRCUIT CONTINUATION IINDICATES GROUND WIRE 1 INDICATES HOT WIRE 1 INDICATES NEUTRAL WIRE 1 INDICATES SWITGHLEG • A PANEL PANEL AND CIRCUIT NUMBER INDICATOR GIRGUIT NUMBER NOTE: NOT ALL SYMBOLS' OR ABBREVIATIONS MAY APPEAR ON PLANS. FIRE ALARM SYMBOLS LEGEND f�,�-1 MANUAL PULL STATION. VERIFY MOUNTING HEIGHT AND LOCATION WITH JURISDICTION HAVING AUTHORITY {� E HAV AUDIOING NISUAL AUTHORITY HORN STROBE. VERIFY MOUNTING HEIGHT AND LOCATION WITH JURISDICTION G/B CIRCUIT BREAKER VISUAL STROBE: VERIFY MOUNTING HEIGHT AND LOCATION( WITH JURISDICTION HAVING AUTHORITY C • ® DUCT MOUNTED SMOKE DETECTOR ® CEILING MOUNTED SMOKE DETECTOR E.G. FLOW SWITCH 2 EXISTING TO REMAIN EF TAMPER SWITCH TS EMERGENCY 0E EXISTING SEMI - RECESSED TYPE SPRINKLER TO REMAIN OR RELOCATED SEMI - RECESSED TYPE SPRINKLER TO REMAIN ON NEW SEMI - RECESSED TYPE SPRINKLER TO REMAIN ©E EXISTING CONGEALED TYPE SPRINKLER TO REMAIN alR, RELOCATED CONGEALED TYPE SPRINKLER TO REMAIN taN NEW CONGEALED TYPE SPRINKLER TO REMAIN )FAGPl FIRE ALARM CONTROL PANEL NOTE: ALL DEVICES SHALL BE COMPATIBLE WITH AND MAINTAIN THE UL LISTING OF EXISTING BUILDING FA SYSTEM. 6.G. SHALL FIELD VERIFY EXACT REQUIREMENTS FOR FIRE ALARM SYSTEM PRIOR TO BID. COORDINATE WITH LOCAL FIRE MARSHALL. SUPPLY AND INSTALL ALL NECESSARY EQUIPMENT. (AUDIONISUAL ALARMS, SMOKE DETECTORS, ETC.) AS REQUIRED. ABBREVIATIONS A.P.F. ABOVE FINISHED FLOOR AHU AIR HANDLER UNIT G/B CIRCUIT BREAKER GKT CIRCUIT CU CONDENSING UNIT D DEDICATED CIRCUIT E.G. ELECTRICAL CONTRACTOR E/EX EXISTING TO REMAIN EF EXHAUST FAN EM EMERGENCY FA FIRE ALARM FAGP FIRE ALARM CONTROL PANEL FLA FULL LOAD AMPS GPI GROUND FAULT CIRCUIT INTERRUPTER HP HORSEPOWER IG ISOLATED GROUND LL LANDLORD LTG LIGHTING MCA MINIMUM CIRCUIT AMPAGITY MOGP MAXIMUM OVERGURIRENT PROTECTION N.I.C. NOT IN CONTRACT ' NL NIGHT L16HT NTS NOT TO SCALE PAR POWER RELOCATED RTU ROOF TOP UNIT T/G TIMEGLOGK TEN TENANT T.G.G. TENANT GENERAL CONTRACTOR TYP TYPICAL U.N.O. UNLESS NOTED OTHERWISE WP WEATHER PROOF XFMR TRANSFORMER 9y) cxrr MAY 31 2012 PENT CENTER TCB12007 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and ,elements of the design. Under such protection, unaufhorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. 0) c co 5.0 et; Isc w • c cuQ in 0 V s � "tii 2 12 aiLisi CONSULTING ENGINEER 0 U 0 0 z O d3 W E Immi EY 71 O U`� w Wes' O n Y O O DATE: 5 -I8 -2012 SHEET: SCALE: DRAWN BY: PROJECT No.: TCBI100 -1 KEYED NOTES 0 PROVIDE A SINGLE PREFAB ROOF PENETRATION WITH SLEEVE. O INALK-IN REMOTE COMPRESSOR ON ROOF. COORDINATE exAcT LOCATION AND DISTANCE FROM WALK-IN REFRIGERATOR. PROVIDE c.oriourr. AND CONDUCTORS THROUGH IAIALK-IN REFRIGERATOR AND INTERCONNECT PER MANUFACTURERS REQUIREMENTS. OPROVIDE 30 AMP/2 POLE NEMA 3R NON-FUSED DISCONNECT AT REMOTE WALK-IN COMPRESSORS ON ROOF PER EQUIPMENT MANUFACTURER REQUIREMENTS. L r ELECTRICAL ROOF PLAN SCALE: 1/4"=1'-0" REVIEWti) i-uti itCOMPLIANCE WITH NFPA 70 - NEC JUN 1 1 2012 City of Tukwila ••• ",.••• •ryrn, BUILDING DIVIsioN TCB12007 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 199D. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, ond/or monetary liability. EL1:02,4*--CiSoo. crreirffgatA MAY 3 1 2012 PERMIT CENTER CONSULTING ENGINEER a 0 0 0 0 n . 0 DATE: 5-1/3-2012 SHEET: SCALE: DRAWN BY: PROJECT No.: TC1512cb01 E2 .0 POWER KEYED NOTES ONOT USED OVERIFY ADEQUATE SIZE AND QUANTITY OF CONDUITS TO ACCOMMODATE NUMBER OF CIRCUITS AND VOICE /DATA REQUIREMENTS INDICATED. 2544'x5/4" THICK MARINE GRADE PLYWOOD BACKBOARD WITH FIRE RETARDANT PAINT IN A COLOR TO MATCH THE SURROUNDING WALLS. INSTALL A #6 INSULATED GU GROUND WIRE TO THE GROUND ELECTRODE AT THE GUTTER. PER NEC SOO.100(A)(I). . 205V 3PH NEMA L -I5 20P POWER CORD PROVIDED WITH SOFT SERVE MACHINE. PROVIDE PROPER RECEPTACLE AS REQUIRED. ELECTRICAL DISTRIBUTION EQUIPMENT. REFER TO SHEET E5.0 FOR FURTHER COORDINATION. 0 NOT USED. 0 NOT USED PROVIDE AND INSTALL NEW J -BOX, DISCONNECT AND CIRCUIT FOR TENANT SIGNAGE. SIGN UNDER SEPARATE PERMIT. SIGN CONTRACTOR TO VERIFY EXACT LOCATION PRIOR TO INSTALLATION. FINAL CONNECTION BY TENANT ELECTRICAL CONTRACTOR. COORDINATE ALL DEVICE LOCATIONS AND CONDUIT ROUTING WITHIN MILLWORK WITH MILLWORK VENDOR. PROVIDE'(I) 5/4 CONDUIT WITH PULLSTRIN6 FOR TELECOMMUNICATION CABLING, FROM NEAREST .ADJACENT 'COLUMN OR WALL, UNDER FLOOR TO POINT OF SALE SERVICE COUNTER BACK TO MANAGERS DESK. . 0 PROVIDE FINAL CONNECTION TO WATER HEATER. O NOT USED O THERMOSTAT LOCATION +45" AFF. PROVIDE CONDUIT WITH PULLSTRING TO ABOVE CEILING. LIGHTING SWITCH BANK III DISPAY COUNTER IG I KITCHEN 1 42 IN. AFF KEYED S NOTES INDICATES THE LIGHTING SWITCH AND CIRCUIT TO BE CONTROLLED. 4 -GANG COMMON FACE PLATE, STAINLESS STEEL, MOUNT LEVEL AND FLUSH WITH THE SURROUNDING WALL. 1 ' I GENERAL DESCRIPTION OF CIRCUIT CONTROLLED LIGHTING KEYED NOTES SWITCH BANK LOCATION. REFER•TO SWITCH BANK DETAIL ON THIS SHEET. ELECTRICAL DISTRIBUTION EQUIPMENT. REFER TO SHEET E5.0 FOR FURTHER COORDINATION. O. UPPER CASE LETTER INDICATES FIXTURE TYPE, REFER TO LIGHT FIXTURE SCHEDULE ON SHEET El.l. LOWER CASE LETTER INDICATES SWITCHING; REFER TO SWITCH BANK DETAIL ON THIS SHEET. O. REMOTE TRANSFORMER FOR LOW VOLTAGE LIGHTING. REFER TO LIGHT FIXTURE SCHEDULE ON SHEET E1.1 FOR FURTHER COORDINATION. II��r1 r- ELECTRICAL POWER PLAN SCALE: I/4 " =1' -0" LWVW COMPIACE TH NFPA 70 - NEC �Y le JUN 1 1 2012 JUN 1 1 2012 C o� Tukwl Ci o Tukw1 `' BUILDING D IVIrON I__... -_. ._.__! L ELECTRICAL LIGHTING PLAN SCALE: 1/4"=I'-0" TCBI 2007 COPYRIGHT NOTICE; These drawings and specifications are copyrighted and subject to copyright protection as an "archiiecturol work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. a co co s w cr° • M. o p cut 4/! RIO ,w. taj M Q CONSULTING ENGINEER U a 0 0 > )E C r'Ncv g • °' 5 Cam. • 16 cio 16; a t� c (,). O E J O •F+ ELt) 0 So 0 crtr MAY 91 2012 PERMIT CENTER DATE: 5 -IS -2012 SHEET: SCALE: DRAWN BY: PROJECT No.: TGBI "1'00'7 i POWER KEYED NOTES OI.. PROVIDE CONNECTION TO CONDENSATE HEAT TRACING TAPE. COORDINATE EXACT ELECTRICAL REQUIREMENTS WITH EQUIPMENT MANUFACTURER. LIGHTING KEYED NOTES PROVIDE FINAL CONNECTION TO WALK -IN LIGHTING. LIGHT FIXTURES PROVIDED BY WALK -IN VENDOR REMOTE STOCKROOM ELECTRICAL POWER PLAN SCALE: 1/4 °= I' -O 1 _i I I A3E k "T NL i ; �.. . '; ><:Z' ' , \� x, , i Ns \ : f 1 A 33 REVIEWEb .tIWH COMPLIANCE WITH NFPA 70 - NEC JUN 1 1 2012 City of Tukwila BUILDING DIVISION REMOTE STOCKROOM ELECTRICAL LIGHTING PLAN SCALE: • I /4 " =1' -O" TCBI. 2007 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright • protection as an "architectural work" under sec. 102 of the copyright act, 17•u.S.C. As amended december 1990. The protection Includes, without limitation, the overall form, orra'!(gement and composition of spaces, and elements o %t the design. Under such protection, unauthorized uitg2£ these drawings and specifications may result, Lil".7 cessation of construction, building seizure, and/or Tribitetary liability. timi) 0) s au 0 INC timl 0 Trial Ili Nom ay% 2 in SEATTLE, WA 98188 CONSULTING ENGINEER W U a 0 O 0 co • a C a 1.s °0. ,^. • 3mg.;' mm O la id D 0 'a u. Z 0 W L 500 R CITY MAY 31 2012 PERMIT COM DATE: .SHEET: SCALE: DRAWN BY: PROJECT No.: E2.2 TCBI2OO1 • G.C. SHALL VERIFY EXISTING SERVICE FEEDERS ARE OF SUFFICIENT LENGTH TO BE PULLED BACK TO NEW PANEL LOCATION. PROVIDE AND INSTALL NEW W NEW LOCATION EXCEEDS FEEDERS LENGTH. KEYED NOTES 0 EXISTING UTILITY COMPANY INCOMING SERVICE. OEXISTING UTILITY COMPANY PAD MOUNTED TRANSFORMER EXISTING WIRING AND CONDUIT TO REMAIN O EXISTING LANDLORD SERVICE DISCONNECT O EXISTING METER BASE AND SOCKET SERVING. TENANT SPACE TO REMAIN. 0 VERIFY EXISTING (s) #6 GU THIN AND (I) #10 GU GNP: IN 5/4" COND. FEEDERS TO 6OA SERVICE DISCONNECT IN SPACE. RELOCATE DISCONNECT AS NECESSARY. EXISTING SUSPENDED 30 KVA TRANSFORMER. RELOCATE AS NECESSARY TO ACCOMMODATE NEI SUSPENDED CEILING. 0 EXISTING IOOA 120/206V RENAMED PANEL "A ". RELOCATE TO LOCATION INDICATED ON PLANS. . OPROVIDE AND INSTALL 24/1 ASTRONOMICAL TIMECLOCK FOR TENANT 516NAGE . 0 VERIFY EXISTING (4) 1$I GU THAN AND (1) #6 &ND IN I -1/2 COND. ROOF LINE 1-l-IOini)i-z.IOi 1Or_. J- _ _1_. J_ I- ± -i--. -f-- -1- -1-- -1- -1-- -1 i n tarn 101 I�I �IOI i I I I r- _..1... _ ' r— - .�- i- _—� 1n101-n-10M 1- 101 1. 1 •1 1. lI - -I UM I L- - - - - --� f I EXIST. 1 rL .j, I XFMR: I II 110' L_..J L I II zm, IRELOCATED' I PANEL 'A' I I ® I L.....--J FINISH FLOOR ELECTRICAL • RISER DIAGRAM SCALE: N.T.S. w 120/208V 3PH -4W . I EL.O ATE D PANEL A Service: 120/208 Volts 3 Phase 4 Wre Cabinets: Surface Mounted Mains :. 100 100A, MCB Total Watts: 33,109 NEMA 1 REM CKT DESCRIPTION WAITS WIRE 12 €2 Liageoc23 IRE DESCRIPTION WATTS CKT REM y 1 KITCHEN WHIN fi ; 4 1/2 ;,,,' ■ 1 ma UNDERCOUNTER REFRIGERATOR 972 2 LD NOTE #2 3 TOPPINGS BAR LIC1 •ITING 855 1/20 1 1 1120 ` NDERCOUNTER REFRIGERATOR 384 4 LD WATER HEATERS 5iG UGH TCI G . 156 12 250 E 1 3120 Ins PAR 33108 NOTES: 1.. 100% OF FIRST 10,000 WATTS , PWS 50% OF REMAINING LOAD. 2. 100% OF LARGER A/C LOAD (COOLING VS HEATING, PLUS 25% OF HIGHEST LOAD. 3. PIECES OF EQUIPMENT :1 -2 =.100%, 3 '' r 4 = 80 %, 5 = 70%, SAND MORE - 66%. SUPPLY /MAUSTFAN r 12 1/20 :C' SOFT SERVE MACHINE 1200 8 LD iD) SOFT SERVE MACHINE 7 :?# 12' a 1200 10 1200 31201 , E . 1200 12 1210 1 3 SOFT SERVE MACHINE 1200 14 LD Li} ' SOFT SERVE MA,C . 1200 12 3120 4I: E: 1200 16 1200 1200 18 19 010 X, ■. : 20 WATER HEATER 1500 20 LQ Lf0 21 SOFT SERVE MAC #1I IE 1230 12 • 41 1500 22 1200 .3120 n 1500 24 1200 I 1 1/28 1 um EA SPARE 26 SPARE WO X■ P.O.S. 500 28 LD TC 31 $ GN SPARE a 1200 12. 1/20 i 1120 GI Q.1 a v am am SPARE 30 FOOD WARMER 996 32 LD 33 L[CIHTING 98 12 11213 ; 11 E Il 1/20 'P/ 1/20 mai FOOD ' NfARMER. 996 ' 34 LD 35 " ALK-IN LIGHTING ?3 .?5O 12 12 Ice ! 1/20 I RECEPTS/ REMOTE STOCK ROOM 360 600 36 38 LD 7 HEAT CE Egi COLD FOOD PAN LQ WALK -IN FREEZER 900 12 SP E 40 900 2J15 ;; E 1 IMP 0 OARD 360 42 LD TOTAL LOAD PHASE W 11202 REMARKS TOTAL LOAD PHASE 8' 11231 (TC) TIME CLOCK CONTROLLED OLLED TOTAL WAD PHASE 'C' 10676 (C#} VIA CONTACTOR (LD) LOCK-ON DEVICE TOTAL LOAD ALL PHASES 33109 VA (IG) ISOLATED GROUND 9197 AMPS (HR) HACR RATED CB (SO) SWITCHING DUTY CB ALL BREAKERS TO 8E 20A S0I.T -ON UNLESS NOTED 0TNERWISE ELECTRICAL SERVICE LOAD SUMMARY 120/208V 3PH -4W . DEMAND LOAD (AMPS) f L+ D D RIP'SON - L. +C iNECTED LOAD (WATTS) DEMAND FACTOR ' DEMAND? LOAD (WATTS) LIGHTING ,. '#69I 125 2114 6 RECEPTACLES . 1220 , NOTE It 1 1220 3 SHOW WINDOW REC 0- 125 CI 0 MECHANICAL 500 NOTE #2 873 2 SIGN LIGHTING .. 12UI 1.25 NOTE # 3 1530 KITCHEN 23748 1.5436 43 WATER HEATERS 4500 1.25 56.E 16 MISCELLANEOUS 250 1.25 -- 313 27C18t) 75 TOTAL . 33108 NOTES: 1.. 100% OF FIRST 10,000 WATTS , PWS 50% OF REMAINING LOAD. 2. 100% OF LARGER A/C LOAD (COOLING VS HEATING, PLUS 25% OF HIGHEST LOAD. 3. PIECES OF EQUIPMENT :1 -2 =.100%, 3 '' r 4 = 80 %, 5 = 70%, SAND MORE - 66%. .REVIEWbU r-Uh COMPLIANCE WITH NFPA 7o - NEC JUN 1 1 2012 City of.Tukwila BUILDING DIVISION ELI oo cr4511#4164 MAY 31 2012 PeRMITGiNTIR TCB12007 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection • includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. a co a s v O0. • M = o p aQ t no .2 2 .lam p M Q 2 tf` H CIW J W V LU J Z an a LE W J W 0?S U ,c CO g CLE —Jb o-o o 2. :o 2 J j' O 0 lam Z0 Q ao DATE: 5 -I5-2012 SHEET: SCALE: DRAWN BY: PROJECT No.: E3.0