Loading...
HomeMy WebLinkAboutPermit EL12-0565 - TARGETTARGET 301 STRANDER BL EL1 2-0565 Parcel No.: Address: City oPi'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov 2623049005 301 STRANDER BL TUKW Project Name: TARGET ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL12 -0565 09/21/2012 03/20/2013 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: TARGET CORPORATION T 0627 C/0 PROPERTY TAX/TPN 0950 , PO BOX 9456 55440 ROBERT HAMLIN Phone: 503- 419 -4688 MULVANNYG2 ARCHITECTURE , 601 SW SECOND AV, SUITE 1200, PORTLAND OR 97204 E C COMPANY Address: P 0 BOX 10286 , PORTLAND OR 97296 Contractor License No: ECCOM ** 148BA Phone: 503 - 224 -3511 Expiration Date: 06/30/2014 DESCRIPTION OF WORK: ELECTRICAL WORK ASSOCIATED WITH THE REPLACEMENT AND ADDIT ION OF RTU'S ON THE ROOF. Value of Electrical: NRES: $10,000.00 Fees Collected: $330.63 RES: $0.00 Type of Fire Protection: UNKNOWN National Electrical Code Edition: 2008 Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied VAAc 1,u Date: DP1l2112 d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not pres construction or the performance of work. Signature: 1/IQIJC I1(Gt�� <i&t to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this electrical permit. Print Name: Date:q ~ 2/ -26/2- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL12 -0565 Printed: 09 -21 -2012 PERMIT CONDITIONS Permit No. EL12 -0565 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -0565 Printed: 09 -21 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite /00 Tukwila, WA 98188 http://www.TukwilaWA Azov Electrical Permit No. G 1--)k— 05625" Project No. I,1.-' I LI Date Application Accepted: (P ')i — 1 Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: 2623049005 301 Strander Blvd - Tukwila, WA 98188 Suite Number: Target Store T -0627 New Tenant: PROPERTY OWNER Name: Robert Hamlin - MulvannyG2 Architecture Name: Target Corporation City: Portland State: OR Zip: 97204 Address: 1000 Nicollet Mall Email: Rob.Hamlin @MulvannyG2.com City: Minneapolis State: MN Zip: 55403 CONTACT PERSON — person receiving all project communication Name: Robert Hamlin - MulvannyG2 Architecture Address: 601 SW 2nd Ave., Suite 1200 City: Portland State: OR Zip: 97204 Phone: (503) 419 -4688 Fax: (971) 998 -1608 Email: Rob.Hamlin @MulvannyG2.com Floor: ❑ Yes m ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: eAt 2-' pd �I2�I►�` Valuation of Project (contractor's bid price): $ 101000. 00 Scope of Work (please provide detailed information): Replacement and addition of RTU's on the roof with associated gas piping and duct work. Will service be altered? ❑ Yes No Adding more than 50 amps? ❑ Yes V] No Type of Use: Retail Type of work: ❑ New m Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy Seattle City Light H:\ Applications \Forms- Applications On Line\2011 Apphcations\Electrical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added /altered circuits $81.90 number of added circuits $11.55 ea m Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added /altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured /mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY 13Y THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: / " Date: 6*096/02 Mailing l7� /�z3�1� /�//� Print Name: 4b e /urge Day Telephone: 3C0-997",000 Mailin Address: < 7 %L��L.P G!/� g H:\Applications \Forms - Applications On Line\20I I Applications\Electrical Permit Application Revised 8 -9 -1 I.docx Revised: August 201 I bh City "J`" State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049005 Address: 301 STRANDER BL TUICW Suite No: Applicant: TARGET RECEIPT Permit Number: EL12 -0565 Status: APPROVED Applied Date: 06/21/2012 Issue Date: Receipt No.: R12 -02649 Payment Amount: $299.88 Initials: WER Payment Date: 09/19/2012 10:44 AM User ID: 1655 Balance: $0.00 Payee: LANKFORD CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 211900 299.88 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 264.50 000.345.832.00.00 35.38 Total: $299.88 doc: Receiot -06 Printed: 09 -19 -2012 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049005 Address: 301 STRANDER BL TUKW Suite No: Applicant: TARGET RECEIPT Permit Number: EL12 -0565 Status: PENDING Applied Date: 06/21/2012 Issue Date: Receipt No.: R12 -01943 Initials: User ID: Payee: WER 1655 Payment Amount: $30.75 Payment Date: 06/21/2012 11:07 AM Balance: $299.88 LANKFORD CONSTRUCTIION CO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 211204 30.75 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 30.75 Total: $30.75 doc: Receiot -06 Printed: 06 -21 -2012 �J�.`NfILA ►vq� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049005 Address: 301 STRANDER BL TUKW Suite No: Applicant: TARGET RECEIPT • Permit Number: EL12 -0565 Status: PENDING Applied Date: 06/21/2012 Issue Date: Receipt No.: R12 -01942 Payment Amount: $ -35.38 Initials: WER Payment Date: 06/21/2012 11:05 AM User ID: 1655 Balance: $330.63 Payee: WRONG AMOUNT ENTERED TRANSACTION LIST: Type Method Descriptio Amount Payment Void 211204 -35.38 Authorization No. ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES Account Code Current Pmts 000.345.832.00.00 -35.38 Total: $ -35.38 doc: Receiot -06 Printed: 06 -21 -2012 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049005 Address: 301 STRANDER BL TUKW Suite No: Applicant: TARGET RECEIPT Permit Number: EL12 -0565 Status: PENDING Applied Date: 06/21/2012 Issue Date: Receipt No.: R12 -01942 Initials: User ID: Payee: WER 1655 Payment Amount: $35.38 Payment Date: 06/21/2012 10:57 AM Balance: $295.25 LANKFORD CONSTRUCTION CO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 211204 35.38 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 35.38 Total: $35.38 doc: Receipt -06 Printed: 06 -21 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 612-0s�s Project: �r l Type of Inspection: 2, (ov Address: Sa I 5r 1 Date Called: r Special Instructions: Date Wanted:. � ap m. P.m. Requester: Phone No: 0Approved per applicable codes. El Corrections required prior to approval. COMMENTS: n plc Date: /Z aJ / iz Inspector: C, 11404 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be . paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • 40 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0565 PROJECT NAME: TARGET SITE ADDRESS: 301 STRANDER BL X Original Plan Submittal Response to Correction Letter # DATE: 06 -21 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Buuifding Division Public Works n Fire Prevention Structural n Planning Division Permit Coordinator ie DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 06-26-12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route IX Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07 -24 -12 Approved ❑ Approved with Conditions I Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople liter Friendly Page • Page 1 of 2 Electrical Contractor A business licensed by Lai to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company E C COMPANY 5032243511 Po Box 10286 Portland OR 97296 Out Of State Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601107330 Active ECCOM * *148BA Electrical Contractor 1/1/1986 6/30/2014 General Unused her Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status ELECTC *542CQ ELECTRICAT CONSTRUCTION OF OR Electrical Contractor General Unused 2/18/1946 12/31/1982 Archived ELECTCC541CQELECTRICAL CONST CO OF OREGON Electrical Contractor General Unused 2/18/1946 12/31/1985 Archived Master Electrician INFORMATION License TRAPPSC976RZ Name TRAPP, STEVEN C Status Active Business Owner Information Name Role Effective Date Expiration Date ADAMS, GEORGE HARRY 01/01/1980 SCROGGY, JOEL J 01/01/1980 BUSINESS FILINGS INCORPORATED Agent 06/28/2010 GOLDSTONE - SCHULLER, LEAH Member 06/28/2012 TRAPP, STEVEN C Member 06/28/2012 SCHMITZ, STEVEN D Member 06/28/2012 BALL, ROBERT SPENCER Member 06/28/2010 JANIK, STEPHEN THOMAS Vice President 06/28/2010 BOCK, JAMES ARTHUR Vice President 06/28/2010 DESHLER, WILLIAM K 01/01/1980 06/28/2010 https://fortress.wa.gov/lni/bbip/Print.aspx 09/21/2012 GENERAL NOTES A. COORDINATE CONSTRUCTION WORK WITH TARGET OSR FOR THE PHASING OF DEMOLITION AND NEW CONSTRUCTION. B. THE CONTRACTOR SHALL REVIEW MECHANICAL DRAWINGS FOR ELECTRICAL CIRCUITS, DEVICES. AND CONNECTIONS TO BE DISCONNECTED AND REMOVED FOR MECHANICAL EQUIPMENT TO BE ABANDONED. THIS SHALL INCLUDE ANY LOW VOLTAGE CONTROLS. C. REMOVE CIRCUITRY BEING DEMOLISHED BACK TO SOURCE OR LAST ACTIVE DEVICE. D. IT IS THE INTENT OF THIS DRAWING TO PROVIDE SCOPE OF DEMOLITION REQUIRED. PROVIDE COMPLETE DEMOLITION AS REQUIRED TO FACILITATE NEW WORK INDICATED WITHIN CONTRACT DOCUMENTS. E. MAINTAIN CIRCUIT CONTINUITY TO DEVICES FED DOWNSTREAM WHICH MAY BE INTERRUPTED DURING CONSTRUCTION. REMOVE CONDUIT AND WIRE ABANDONED DURING CONSTRUCTION. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 1 F _ _ HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz T ELECTRICAL POWER DEMOLITION PLAN T: \Special_ Projects \2012_Special_ Projects \0627_WA South_Center HVAC VVT Conv Bct #162675 \_ActiveCAD \0627ed22.dgn 116" =1' -0" DATE ISSUED ISSUES AND REVISIONS VERSION 31 MAY 2012 05.31.12 - PERMIT SET ELECTRICAL DEN4JLITKJ ROOF PLAN DRAWN BY A. KELLY CHECKED BY R. OLSON ARCHITECTS PROJECT NO. 31— MAY -2012 14:23 KEY NOTES 0 EXISTING RTU UNITS TO BE DEMOLISHED. REMOVE ALL CONDUIT AND ASSOCIATED WIRING AS REQUIRED. LABEL EXISTING BREAKER AS 'SPARE'. REVIEWED TCOMLIE W H NFPA70 - NEC JUL 11 2012 City of Tukwila BUILDING DIVISION �LI� -0 56s TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION TITLE PROJECT CODE 270627 CONFIGURATION LL ELECTRICAL DEN4JLITKJ ROOF PLAN RECEIVED JUN 212012 FERI►IIT CENTER SHEET ED22 T -0627 SOUTH CENTER, WA. U 42 RTU -1A GENERAL NOTES A. REFER TO SHEET E601 FOR ROOFTOP CIRCUITING. B. ROUTE FEEDER CONDUITS FROM ELECTRICAL PANEL TO THE UNIT DISCONNECT (CIRCUIT BF2EAKER) FURNISHED WIN THE RTU /DHU. GROUND CONDUIT DIRECTLY TO JUNCTION BOX OF THE UNIT DISCONNECT. REFER TO C. ROUTE CONDUITS THROUGH ROOF WITHIN ROOF CURBS. D. RTU'S TO BE CONNECTED TO EXISTING EMS. PROVIDE EMS CABLING TYPE 22/2 AWD CL2P SHIELDED PURPLE CABLE TO RTU CONTROL PANEL. PROVIDE 18/2 AWG CL2P SHIELDED FROM NEW TEMPERATURE SENSOR TO CONTROL PANEL. PROVIDE ANY ADDITIONAL CABLING BACK TO EMS TO ENSURE A COMPLETE WORKING SYSTEM. KEY NOTES El PROVIDE GFCI, WP RECEPTACLE. PROVIDE DUCT DETECTION TO SUPPLY SIDE OF RTU. CONNECT TO EXISTING FACP. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz ROOF POWER PLAN T: \Special_ Projects \2012_Special_Projects \0627 WA South_Center HVAC WT_Canv Bct #162675 \_ActiveCAD \0627e221.dgn 1/4" =V-0" DATE ISSUED • ISSUES AND REVISIONS VERSION 31 MAY 2012 05.31.12 - PERMIT SET DRAWN BY A. KELLY CHECKED BY R. OLSON ARCHITECTS PROJECT NO. 31— MAY -2012 14:23 PROVIDE CONDUITS FOR LOW VOLTAGE (FA & EMS) CABLES. EXTEND CONDUITS A MINIMUM OF 18' ABOVE THE BOTTOM OF THE CONTROL CABINET, BUSH & SUPPORT CONDUITS. ROUTE FEEDER CONDUIT TO J-BOX ENCLOSING THE UNIT DISCONNECT (CIRCUIT BREAKER). PROVIDE GROUND WIRE TO J -BOX. ALL CONNECTIONS SHALL BE LIQUID TIGHT. USE KNOCKOUTS PROVIDED. NO OTHER PENETRATIONS ALLOWED. SEAL ALL UNUSED OPENINGS WITH EPCO DUCTSEAL COMPOUND. RTU WIRING LIQUIDTIGHT FIT1ING LIQUIDTIGHT COOUIT / I � III , N MC FITTING COUPLING LIQUID TIGHT FlT TING DETAIL REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC JUL 1 1 2012 City of Tukwila BUILDING DIVISION NOT TO SCALE 56S TARGET STORE SOUTH CENTER v\/ A 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION TITLE W E R P 'A N PROJECT CODE 270627 CONFIGURATION LL R OOF P O L.A RECEIVED JUN 212012 PERMIT CENTER SHEET [221 T -0627 SOUTH CENTER, WA. } L 1 1 ' lU.. Y 3 DESCRI PT ION LOAD LOAD BREAKER KVA On' TYPE AM Pi POLE # BREAKER LOAD LOAD AMP/ POLE TYPE QTY KVA DESCRIPTION 4 { r "' 3 A..1, )L t: S.c... % i 9 a <.r.,... .i.:.F 1 . '. •E E.f iS.Y 4 : ::.1 ' /3 RTU-1A RT U -1 B RTU-2A Demand Load Phase A Phase B Phase Tot Average Spares not included 6 2 5259 5.2'50 525g 3.322 3.322 3.322 5.25 5.28 5_.26 KVA -) 4:7: . } >. j3. .t J r PN (1) MS M MS MS MS MS MS MS MS (1) A : A s Cr 25/3 .25 .S:\:'. C 15/3 3 1 A : 33 • '°' 4 • • 3' 3: 25!3 x r5. MS (1) MS MS if F J �F 2. 4,4 x 0 '. c. ". t.. SPARE SPAR S' # s: II of r. f p P.)710 T f•. „SP APE 4 .<y. WH- 4705 RTU -2B 4.706 4.700 FOCAL TING 3 FOCAL. VA LA ti 1GH T I -III;7e 111111. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 Type L R PN PW MN MNI MS MW KT Total KVA Factor KVA 15.5 1.0, 11.0 3_0 0.0 0.0 55.6 1' .5 0.0 87.6 x 1.25 x 0.5 = x 1 x1= x1_ x1= x1= x = x 0.615 19..4 1.0 *100% of 1st 10kva, plus 5 11.0 3.0 0_0 0.0 55.6 1.5 0.0 91.5 erriatnde 87.5 81.5 110.1 T ota l Connected KVA' Total Demand KVA Total Demand Amps HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz i T: \Special Projects \2012 Special Proiects \0627 WA South Center HVAC WT Cony Bct #162675 \_ActiveCAD \0627e601.dgn ?::/:v/ •.20 }J ...,..V { }: ,+ 0.0;-.70 20-21X..- ..t ...k sr iJ .. .... r, }...., +,t.:+ .. / .,:'.., •x DESCRI PTION LOAD LOAD BREAKER KVA QTY TYPE AMP/ POLE BREAKER LOAD LOAD AMP / POLE TYPE QTY KVA DESCRI PT ION .t :.' ^v �::„ S' > SEA WRAP .'tom.,c.3.C...,T`va Z.: • }• Ca : r":# :/' r ?(k. C .,..,..: f> s£:CA ?: PS MAINE.. R it -.�:- ; s' t: ?G,`. g : e # a ,:.: :.� �f.: Sr...t ... : ; rani' . x.r 3 .Z. 0 ". X: Cf { ``...i} 7 z { TV} }.a . -38 r. 7 t +: ...t.i �+ : : 3i /: 3� . a }�...,. <'�`uf ,. ... , 7O V;C g t a r ) , MF1?..4. }: R�+ R: $ } c >j �i 1 A f: 0' .;' max' 2011 }1 A.R%`.: 7 70 - 20/1 C 12 A 14 1: T. 20/1 o }} 23 { 'a}a t r} Demand Load KVA AMPS Phase A Phase B Phase C Total Average *Spares not tncluded 11.1' 9.7 11.0 31.8 92.5 80.5 91.6 88.2 • PN W t. 's }F/1 Type KVA Factor KVA L 0.0 R 11.1 PN 6.2 Pw 9.0 MN MNI MS MW KT 5.4 0.0 0.0 0.6 0.0 Total 32.3 x 125 x0.5= x1 x1:= x1= x1 x1= x1= x 0.66 PN I HAND 4 D i.+ RE wr)r f.. : A. . 5 (1) 1 0.8 ROOFTOP RECEPTACLE LE 0.0 10.6 100% of 1st 101tva, plus 50% o 6,2 9.0 5.4 0.0 0.0 0.6 0.0 31.8 RTU ROOF TOP UNITS LOCATI ON VOLTP i LOAD TYPE WIRE & CONDUIT CONTROL PANEL/ CIRCUIT LOCAL DISC 1A ROOF TOP. UNIT 1B ROOF TOP UNIT 2A ROOF TOP UNIT 2B ROOF TOP UNIT ROOF ROOF ROOF ROOF 480 3 15.8 KW 3#10,#10G, 3/4"C EMS 480 3 10.€ KW 3 #12= #12G, 3/4"C EMS 480 3 15.8 KW 3#10,#10G, 3/4"C EMS 480 3 14.1 KW 3##1€1,#1 OG= 314 "C EMS H L -3/ 25,27,29 H L-3131,33,35 H L -3! 37,39,41 HL- 3!3QQ32,34 30A 30A 30A 30A 0-DIRECT CONNECT R-RECEPTACLE I HEIGHT NOTES D D D D 32.3 31.8 88.2 rematnder. Total Connected KVA Total Demand KVA Total Demand Amps DATE ISSUED ISSUES AND REVISIONS / 31 MAY 2012 05.31.12 - PERMIT SET DRAWN BY A. KELLY CHECKED BY R. OLSON ARCHITECTS PROJECT NO. 31- MAY -2012 14:23 REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC I JUL 1 1 2012 City of Tukwila BUILDING DIVISioN! �LI� --05bs RECEIVED JUN 212012 PERMIT CENTER GENERAL NOTES A. PROVIDE HANDLE TIES FOR SIMULTANEOUS DISCONNECTING MEANS OF MULTIWIRE BRANCH CIRCUITS PER NEC 210.4. PANELBOARD LOAD LEGEND R - RECEPTACLE L - LIGHTING PN - POWER NON- SEASONAL PW - POWER WINTER MN - MOTORS NON- SEASONAL MNI - MOTORS NON-SEASONAL INTERMITTENT MW - MOTORS WINTER KT - KITCHEN SR - SPARE SC - SPACE • - GFCI BREAKER ( ) - INDICATES NUMBER OF CONNECTIONS TO CIRCUIT •• - PROVIDE MECHANICAL TIE FOR SPLIT WIRE RECEPTACLE TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION TITLE PROJECT CODE 270627 CONFIGURATION LL SCHEDULES SHEET E601 T -0627 SOUTH CENTER, WA