Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL12-0634 - SEARS
SEARS 18340 OLYMPIC AV S EL1 2-0634 City offtukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.Tukw ila WA .gov Parcel No.: 7888900155 Address: 18340 OLYMPIC AV S TUKW Project Name: SEARS ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL12 -0634 10/19/2012 04/17/2013 Owner: Name: C/O EPROPERTYTAX INC Address: DEPT #207 , PO BOX 4900 85261 Contact Person: Name: SETH BROWN Address: 421 E CERRITOS AV , ANAHEIM CA, 92805 Contractor: Name: OSTLUND ELECTRIC INC Address: 1006 A ST SE , AUBURN WA 98002 Contractor License No: OSTLUEI318DS Phone: 714 - 491 -1317 Phone: 253 833 -5282 Expiration Date: 05/08/2013 DESCRIPTION OF WORK: ELECTRICAL FOR TENANT IMPROVEMENT Value of Electrical: NRES: $80,000.00 RES: $0.00 Fees Collected: Type of Fire Protection: UNKNOWN National Electrical Code Edition: Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and ex governing this work will be complied The granting of this construction or Signature: Print Name: $1,664.25 2008 this permit and know the same to be true and correct. All provisions of law and ordinances ether specified herein or not. e authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this electrical permit. z-N-7/0f7./z Date:/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL12 -0634 Printed: 10 -19 -2012 • PERMIT CONDITIONS • Permit No. EL 12 -0634 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -0634 Printed: 10 -19 -2012 CITY OF TUKWI.. Community Developme,. 1iartment Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http:Pwww.TukwilaWA.gov ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 1(;'34-0 �. O(;\ R Tenant Name: &S t Y U King Co Assessor's Tax No.. U 00160 Floor: New Tenant: /`"" Yes ❑.. No Suite Number: Name: • e �fi � Name: eth r , . Address: I lib 1#4I EIRIMMISIMIIIIMS Phone: 14 _ g , ,Fax: IMEMilli Company Name: 4 j t4 N Address: low , City: Av‘64114A State: ` J p Zip: ar an Phone: n c- 674?x: Contr Reg No.by.nAA6. 9 xp Date: Gil Tukwila Business License No.; Valuation of Project (contractor's bid price): $ GCC Scope of Work (please provide detailed information): ,re( Fb i Will service be altered? Yes ❑ No Adding more than 50 amps? Yes Type of Use: Type of work: ❑ New ❑ Addition i Service Change ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H: \Applications\Forms- Applications On Line \2011 Applications\Electrical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $152.85 $81.90 ea $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added /altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured /mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE ' • R ELECTRICAL CONTRACTOR: J1 Signa l...�� __, Date: d7 (e2 (17i Print Nam e: / 1 tA/N i/L5 Day Telephone: 71'1- 7 -- (0g Mailing Address: LL ( C6)(0 s o S (/ r ,l K., ( � 5o5-- Ctty State Zip H:Wpplications\Forms- Applications On Line \2011 Applications\Electrical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 2 of 2 J��1LA wq� City of Tukwila r�� \y Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7888900155 Address: 18340 OLYMPIC AV S TUKW Suite No: Applicant: SEARS RECEIPT Permit Number: EL12 -0634 Status: APPROVED Applied Date: 07/06/2012 Issue Date: Receipt No.: R12 -02896 Payment Amount: $1,331.40 Initials: WER Payment Date: 10/18/2012 10:48 AM User ID: 1655 Balance: $0.00 Payee: ICE BUILDERS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 122183 1,331.40 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 1,331.40 Total: $1,331.40 dnc• RAreint -OR Printed• 1 n -1 R -2012 Cit,of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: hug : /hvww. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -02063 Initials: WER Payment Date: 07/06/2012 User ID: 1655 Total Payment: 2,565.42 Payee: ICE BUILDERS INC SET ID: 070612 SET NAME: SEARS SET TRANSACTIONS: Set Member Amount D12 -235 EL12 -0634 PG12 -142 TOTAL: 1,761.11 332.85 471.46 1,761.11 TRANSACTION LIST: Type Method Description Amount Payment Check 119151 2,565.42 TOTAL: 2,565.42 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 TOTAL: 332.85 2,232.57 2,565.42 INSPECTION RECORD _� / Retain a copy with permit Et11 a J INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 1 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: l s n 5 Type of Inspection: Address (g3Lt 0 %MAC/ Date Called: Special Instructions: Date Wanted:. (1 (2-0 a.rrN cri.r9) Requester: Phone No: D;Approved per applicable codes. El Corrections required prior to approval. i COMMENTS: tri Nis . Date: /io I n i I I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6,12 v434 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: � '' Type of Inspection: Gldc.) Address: 1 /' '3'ww c)1y11P(C' Date Called: Special Instructions: Date Wanted:. a. Requester: , Phone No: . Approved per applicable codes. COMMENTS: ctCorrections required prior to approval. Ak Inspector: Date: r' Jr Q f� n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 3 INSPECTION NO. INSPECTION,RECORD Retain a copyywith permit 6,17._-031 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 1Q= (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 660,5 Type of Inspection:71.. 00 Date Called: Address: I3 70 Ot 1 me Special Instructions: ' Date Wanted:. 11 /o7 Requester: -% eL Phone No: 1 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: Kl- l ! i ti - -% eL 1 - O 1eKdii5 r1 f kT7o 6ecw4Pr,i, SPA /NAiti Date: / I /0/ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: 4,l#1604ric INSPECTION RECORD. (142--06131/ Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 /X_ Project: Type of Inspection: Address: /F3 IN DPPOC/ Date Called: Special Instructions: Date Wanted:. / <f Of a.m., C.' Requester: Phone No: 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: ()e)JP1 RM"A4t, orb (Jokn4 �R1� ,. Inspector: Date: s l O r �Z- r n REINSPECTION FEE REQUIRED. Prior to next inspection. fee'must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: cG R n Type of Inspection: -1/ Address: n3, yo yrtPic / (/ r Date Called: Special Instructions: Date Wanted:. jj /? (Q / J a.m. p.m. Requester: Phone No: )(IApproved per applicable codes. Corrections required prior to approval. COMMENTS: (X 604/N( 13 Date: /0/31 fiz CJIP16 "—I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: July 26, 2012 • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Seth Brown ICE Builders 421 E Cerritos Av Anaheim, CA 92805 RE: Correction Letter #1 Electrical Permit Application Number EL12 -0634 Sears —18340 Olympic Av S Dear Mr. Brown, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. Building Department: Jim Benner at 206 - 431 -3679 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, 'cdoV Bill Rambo Permit Technician encl File No. ELI2 -0634 W: \Penit Center \Correction Letters \2012\EL12 -0634 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Jim Benner, Electrical Inspector Building Division Review Memo Date: July 25, 2012 Project Name: SEARS Permit #: EL12 -0634 Plan Review: Jim Benner, Electrical Inspector The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). Please include One Line Diagram, Load Summary, and Panel Directories (where applicable) 1. Balance Toads across phases on Panels D, E, F, and G. 2. Sheet E -4. Panel schedule for MDP should reflect 200/3 breaker for Panel E. 3. Ensure 1 foot/candle (average) emergency lighting along path of egress, measured at the floor. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. 41)PERMIT COORD COM PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0634 PROJECT NAME: SEARS SITE ADDRESS: 18340 OLYMPIC AV S DATE: 09/13/12 Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEPART ENTL S: ui ding 'vision Fire Prevention Planning Division Public Works . Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 'VI Incomplete ❑ DUE DATE: 09/18/12 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route [41 Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: DUE DATE: 10/16/12 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: EMTc000c.v PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0634 PROJECT NAME: SEARS SITE ADDRESS: 18340 OLYMPIC AV S X Original Plan Submittal Response to Correction Letter # DATE: 07 -06 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPA TMEN S: ul dln Ivlsi Public Works Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 07-10-12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08-07 -12 Approved Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: '—.)-10 — Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 frib City of Tukwila REVISto N:..,. SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 09/10/2012 Plan Check/Permit Number: EL12 -0634 Response to Incomplete Letter # ,/ Response to Correction Letter # 1 Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Sears Project Address: Contact Person: 18340 Olympic Ave South Summary of Revision: 1. "Balance loads across phases on panels D, E, F, AND G." R: See revised panel schedules and added note on sheet E -4. Phone Number: 2. "Sheet E -4. Panel schedule for MDP should reflect 200/3 breaker for Panel E." R: See revised panel schedule on sheet E -4. RECEIVED SEP 13 20121 3. "Ensure 1 foot/candle (average) emergency lighting along path of egress. Measured at the floor." R: See revised note on sheet E -1. k1MIT CENTER Sheet Number(s): E -1 & E -4: Revision #4, "Issued For Permit Comments" dated 9/10/12 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Cei ter by: / V' Entered in Permits Plus on 0I 11' FI: \ Applications \Forms-Applications On Line \2010 Applications \7 -2010 - Revision Submival.doc Revised: May 201 I 1 Contractors or Tradespeople PIS Friendly Page Electrical Contractor A business licensed by LEI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company OSTLUND ELECTRIC INC 2538335282 1006 A St Se Auburn WA 98002 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 600055689 Active OSTLUEI318DS Electrical Contractor 3/10/1969 5/8/2013 General Unused Master Electrician INFORMATION License OSTLUR "962R1 Name OSTLUND, ROBERT A Status Active Business Owner Information Name Role Effective Date Expiration Date OSTLUND, KEITH E Violation Amount 01/01/1980 9/18/2009 OSTLUND, ARLIS J ELECTRICAL CITATION 01/01/1980 $250.00 OSTLUND, KIM L 9/18/2009 01/01/1980 ELECTRICAL CITATION OSTLUND, KEITH E Agent 01/01/1980 4/30/2012 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 CBIC 608234 11/28/1980 Until Cancelled $4,000.00 09/14/2008 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EMABQ03121 9/18/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EMABQ03122 9/18/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EDUNY00231 4/30/2012 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 EMABQ03125 9/18/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EMABQ03126 9/18/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 10/19/2012 (o) (E (D TV LOCK TRACTOR REPAIR 49' x 15' (EXHAUST TO CODE) TREADMILL REPAIR LUMINAIRE SCHEDULE LUMINAIRE LOCATION STYLE MANUFACTURER / CATALOG NO COUNT POWLAER MINPS PUT / REMARKS SEPTEMBER 10, 2012 EXIT SIGN 120V /SELF POWERED, L.E.D. EXIT SIGN SURE -LITES / LPX7ORWH — L.E.D. EXIT SIGNS SHALL MEET STATE & LOCAL BUILDING CODE REQUIREMENTS. EM BATTERY 120V, EMERGENCY BATTERY UNIT SURE -LITES / CC5 — (2) 9W INCANDESCENT EMERGENCY BATTERY UNIT SHALL MEET STATE & LOCAL BUILDING CODE REQUIREMENTS. P 01 ∎74 EM BATTERY 120V COMBINATION EXIT SIGN/ EMERGENCY BATTERY UNIT SURE -LITES / LPX7ORWH -DH — (2) 72W INCANDESCENT EXIT /EMERGENCY BATTERY UNIT SHALL MEET STATE &LOCAL BUILDING CODE REQUIREMENTS. REMOTE HEAD WEATHER PROOF REMOTE HEAD SURE -CITES / 6XW7WMHWH - (1) 7.2W INCANDESCENT 4J IIlliIIIL L__ vAA'TRESS FORAGE 11 D /26 BINS 35' x 10' D /26 BINS 35' x 10' MATTRESS 1 ORS WAIT FOR STAGING • 'f PARTS 30' x IT 11 4:7' x 20' ORS REPAIR 4' x TREADMILL ASSEMBLY 0 /26 BINS 35` x 1(Y mal/ MAIN AISLE-1 (IDE rn[Pri L) ili PAINT' r, X11 r: PRS REPAIR 50' x 27' 40' x 10' D /22 BINS 35' x 10' BOXED OVERSTOCK - G -x 32! PRE STAG' 40'x14' • D /4,)S BINS • 3)'x10' ;I I JANUARY 6, 2012 ' ISSUED FOR BID MAY 1, 2012 ISSUED FOR REVISIONS & PERMIT JUNE 27, 2012 AISSUED FOR PERMIT COMMENTS D/4t BINS 35'x14' D106, 71 BINS STOW 35' x 10' DEEP CLEAN/ CLEANING . 751-:0-72 1374.3— — . aC.._Jf...:I:`1 RANGES/LAUNDRY/0W STAGING NON - SALEABLE MDSE. 2(.)' x 19' 40' x 35' REFRIGERATOR STAGING -ry Ri PAtR/ — STORAGE 40' x 20' STOW 351x 0' T JUNK 20 x 16' SINK STOW 35' x 10' DTI 1 TO = AL-WH-UE AREA I 1 1 1 . - -_ -_ :_: 1 - L_ _ r —� l =?:,� EMERGENCY, EXIT AND LIGHTING PLAN NORTH SEPARATE PERMIT REQUIRED FOR EffIllechaniost © Electrical Crr Wne Was Pipit Oil of Tukwila EL . "'!NG DIVISION REVISIONS No changss shall be made to the scope 1 4ithout prior approval of 7i!a Building Division. , will require a new plan submittal may in l IJde additional plan review fees. .._trr.SWite —c FILE COP p m milt o. E L1 - -ObS'I pir m ie approval is subject to errors and omissions. of construction documents does not authorize t {; stion of ` any adopted code or ordinance. Receipt pIVovd Field, t .: n k ns ckno�rledged: 1 j By Data. City Of Tukwila BUILDING DIVISION REVIEWED FOR COMPLIANCE WITH A70 -NEC SEP 2 8 2012 City of Tukwila BUILDING DIVISION ABBREVIATIONS AFF AFG UON NEC ECR IG CKT GP JB SC WP LAN F &I ABOVE FINISHED FLOOR ABOVE FINISHED GRADE UNLESS OTHERWISE NOTED NATIONAL ELECTRICAL CODE ELECTRONIC CASH REGISTER GROUND ISOLATED GROUND CIRCUIT CONDUIT: EMT UNLESS NOTED OTHERWISE GENERAL PURPOSE CIRCUIT OR RECEPTACLE JUNCTION BOX SEPERATE CIRCUIT WEATHER PROOF LOCAL AREA NETWORK FURNISH AND INSTALL SYMBOL LEGEND V dip dbWP THIN LINE WEIGHT REPRESENTS EXISTING THICK LINE WEIGHT REPRESENTS NEW THIN DASHED LINE WEIGHT REPRESENTS EXISTING TO BE REMOVED TYPICAL CONDUCTOR IDENTIFIER SHORT LINE = PHASED CONDUCTORS LONG LINE = NEUTRAL GROUND DUPLEX RECEPTACLE AT 18 "AFF UON GFI DUPLEX RECEPTACLE DEDICATED DUPLEX RECEPTACLE WEATHER PROOF DUPLEX RECEPTACLE DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER DOUBLE DUPLEX RECEPTACLE SPECIAL PURPOSE RECEPTACLE AS NOTED 0 JUNCTION BOX POWER POLE • CORD REEL (GRAINGER #6YF67) Mal POWER PANEL ✓ TELEPHONE RECEPTACLE, CONDUIT IN WALL AND 3" STUB UP ABOVE FINISHED CEILING WITH PULL STRING ✓ DATA RECEPTACLE, CONDUIT IN WALL AND 3" STUB UP ABOVE FINISHED CEILING WITH PULL STRING ✓ COMBINATION TELEPHONE / DATA, CONDUIT IN WALL AND 3 " STUB UP ABOVE FINISHED CEILING WITH PULL STRING $a $3 $M $T EP 20A SINGLE POLE TOGGLE SWITCH LOWER CASE LETTERING - SWITCH IDENTIFIER 3 WAY 20A SINGLE POLE TOGGLE SWITCH MOTION SWITCH (LEVITON #OSSMT -MD) THERMALLY PROTECTED SWITCH FUSED DISCONNECT MOTOR �\ ELECTRICAL CONDUIT OVERHEAD ® PLUGMOLD AS NOTED 1' x 4' FLUORESCENT 2' x 4' FLUORESCENT 2a NUMBER - CIRCUIT NUMBER LOWER CASE LETTER - SWITCH IDENTIFIER STRIP FIXTURE SINGLE FACE EXIT SIGN WALL MOUNT BATTERY PACK CEILING MOUNT BATTERY PACK 1' x 4' FLUORESCENT N/L 2' x 4' FLUORESCENT N/L STRIP FIXTURE N/L SHEET NOTES 1. ALL NEW EXIT /EMERGENCY LIGHTING IN BOLD TYPE TO BE CONNECTED TO LOCAL LIGHTING CIRCUIT AHEAD OF ANY LOCAL SWITCHING. 2. EC TO VERIFY THAT ALL EXIT /EMERGENCY LIGHTING SHOWN IN FINE TYPE ARE INFACT EXISTING IN LOCATIONS SHOWN PRIOR TO BID. 3. EXIT AND EMERGENCY LIGHTING DEVICES AS SHOWN ARE INTENDED TO PROVIDE AN ADEQUATELY ILLUMINATED PATH OF EGRESS AND ARE ASSUMED TO BE EXISTING TO REMAIN UNLESS OTHERWISE NOTED. - EC TO ENSURE AN AVERAGE OF ONE (1) FOOT CANDLE AT FLOOR ALONG PATH OF EGRESS, INSTALL NEW UNITS AS REQUIRED, REMOVE ANY CONFLICTING DEVICES AND INSTALL ADDITIONAL DEVICES IF /AS DIRECTED BY PROJECT MANAGER AND /OR LOCAL AUTHORITIES. 5. ALL GENERAL LIGHTING IS EXISTING TO REMAIN. RiECtiVW ci ry OF MOW A HP 13 2012 PERMIT CENTER E 0 LI S CORRECTION L7R# L ISSUE DATE ISSUED FOR SCOPE OF WORK JANUARY 6, 2012 ' ISSUED FOR BID MAY 1, 2012 ISSUED FOR REVISIONS & PERMIT JUNE 27, 2012 AISSUED FOR PERMIT COMMENTS SEPTEMBER 10, 2012 SEARS HOLDINGS w —J 0 w _. 0 0 z 0) w I- 0 z_ z J CL 00 z 1- 0 J Project ArchJ Engineer: M.PELINI Drawn: J. FALLOS Checked: J. LINEGAR Date: OCTOBER 28, 2011 Sheet No: E -1 (9) OUTLET STOCK (7) G \. EF') E (D (A REFRIGERATORS LV WIRING BY OTHERS (t a ap ROUTE CONDUIT UNDER COUNTER 1-3#12,1#12G,3/4"C TO PANEL "LA" CKTS 14.16 —2#121#12G3/4'C —TO PANEL "A" CKT 9 PANEL "A" a LV W RING BY OTHERS 2#12,1#129,3/4"C TO PANE A" CKTS 8 0 SOLUTION CENTER ROTE CONDUIT _ _L ER COUNTER 0) (2) 16 FT. "2 #12,1 #12G,3/4 "C TO PANEL "A" CKT 11 SEASONAL/ PROMO 3 #12,1 #12G,3 14 "C - TO PANEL "A CKTS 7,9 LV WIRING BY OTHERS SEE DETAIL 1 4 ON SHEET E -3 (TYPICAL) 4 #12,1 #12G,3 /4 "C TO PANEL "A" CKTS 1,3,5 12G, 3/4 "C • EL"A MERCHANDISE ELECTRICAL POWER PLAN 32' -0" NORTH SCALE: 1/8" = 1' -0" 2 #12,1 #12G,3/4 "C TO PANEL "B" CKTS 2 OUTB0I ELECTRICAL GENERAL NOTES AND SPECIFICATIONS 1. INSTALLATION OF ELECTRICAL WORK SHALL CONFORM WITH LOCAL REGULATIONS AND ORDINANCES, STATE REQUIREMENTS AND THE LATEST NATIONAL ELECTRICAL CODE. 2. ELECTRICAL CONTRACTOR SHALL VISIT JOB SITE AND DETERMINE EXISTING CONDITIONS AND LIMITATIONS UNDER WHICH THE WORK IS TO BE PERFORMED. THE SUBMISSION OF A BID SHALL BE CONSTRUED AS INDICATING SUCH KNOWLEDGE THAT SUCH EXAMINATION HAS BEEN MADE AND VERIFIED. 3. NEW INSTALLATION INCLUDING MATERIAL AND EQUIPMENT SHALL BE EQUAL TO ORIGINAL INSTALLATION. . 4. ALL NEW CONDUCTORS SHALL BE COPPER TYPE THHN (ABOVE GROUND) RUN IN ELECTRICAL METALLIC TUBING (EMT/THIN WALL) AND TYPE THWN/THHN (BELOW GROUND) RUN IN PVC OR GRC CONDUIT. 5. ELECTRICAL CONTRACTOR SHALL PROVIDE TYPED DIRECTORY FOR NEW PANELS AND ALL EXISTING PANELS BEING AFFECTED BY THIS WORK. 6. ALL ELECTRICAL DISTRIBUTION EQUIPMENT(i.e. PANEL BOARDS etc.) ARE EXISTING TO REMAIN UNLESS NOTED AS NEW. 7. PROVIDE AN INSULATED, ISOLATED GROUND SYSTEM THROUGHOUT AS INDICATED ON DRAWINGS. FOR ELECTRONIC CASH REGISTER (ECR) SYSTEM. PROVIDE ONE INSULATED ISOLATED GROUND WIRE FOR EACH CIRCUIT. PLACE A MAXIMUM OF TWO (2) ECRS ON A SINGLE DEDICATED / ISOLATED CIRCUIT. 8. RECEPTACLES FOR ISOLATED GROUND CIRCUITS SHALL BE AS FOLLOWS: SINGLE - HUBBELL #IG5251 (ORANGE) DUPLEX - HUBBELL #IG5262 (ORANGE) U.O.N. 9. PROVIDE SCREW FASTENED HANDLE LOCK -ON DEVICES AT CIRCUIT BREAKERS FOR ALL REFRIGERATION EQUIPMENT, CASH REGISTERS, ALARMS AND AS DIRECTED IN FIELD BY SHC PROJECT REPRESENTATIVE. 10. FINAL LOCATION OF DEVICES AND EQUIPMENT TO BE VERIFIED WITH SHC PROJECT COORDINATOR PRIOR TO INSTALLATION. 11. HOME RUNS SHOWN SEPARATE FOR CLARITY ONLY. CIRCUITS MAY BE COMBINED FOR MOST COST EFFECTIVE INSTALLATION, BUT MUST COMPLY WITH ARTICLE #310 DERATING FACTORS FROM THE LATEST NATIONAL ELECTRIC CODE AS IS APPLICABLE. 12. IT IS THE RESPONSIBILITY OF THIS ELECTRICAL CONTRACTOR TO VERIFY AT THE JOB SITE ACTUAL AVAILABILITY OF CIRCUITS REQUIRED. CIRCUITS INDICATED ARE DERIVED FROM AVAILABLE INFORMATION. DIFFERENT CIRCUITS THAT HAVE BECOME AVAILABLE IN THE CEILING SPACE DUE TO RELOCATION OF ELECTRIFIED DEVICES MAY BE SUBSTITUTED FOR CIRCUITS INDICATED ON THE DRAWINGS, PROVIDED THOSE CIRCUITS ORIGINATE FROM SOURCE PANELS WITH SIMILAR ELECTRICAL CHARACTERISTICS. 13. THE INTENTION OF THESE DRAWINGS IS TO INDICATE THE ROUGH IN POWER REQUIREMENTS FOR STORE MERCHANDISE FIXTURES AND CASH REGISTERS. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY THE EXACT LOCATION OF EACH OUTLET WITH THE SHC PROJECT REPRESENTATIVE USING FINAL STORE PLANNING FIXTURE LAYOUT PRIOR TO INSTALLATION. 14. ALL OUTLET BOXES FOR DROPS TO SALES AREA FIXTURES MUST BE LOCATED IN CEILING SPACE AND SECURED TO BUILDING STRUCTURE. 15. ALL WIRES SHALL BE LABELED WITH AN IDENTIFICATION TAG TO INDICATE THEIR SOURCE. 16. MINIMUM CONDUCTOR SIZE FOR HOME RUNS SHALL BE #12 THHN IN 1/2" CONDUIT. 17. THE CONTRACTOR MUST INSURE THRU COORDINATION WITH STORE MANAGER AND PROJECT REPRESENTATIVE THAT DURING CONSTRUCTION STAGES, PROCEDURES SHALL BE ESTABLISHED TO ENSURE CONTINUED, UNINTERRUPTED STORE OPERATIONS. ANY ACTIVITIES AFFECTING SYSTEMS WHICH ARE VITAL TO THE CONTINUOUS OPERATION OF THE STORE SHALL BE IMPLEMENTED DURING OFF - HOURS. CONSTRUCTION DURING STORE OPERATING HOURS SHALL BE LIMITED TO MINIMAL INTERRUPTIONS DURING SLOW BUSINESS HOURS AT PROJECT MANAGER'S DISCRETION 18. IN GENERAL, MULTI - OUTLET PLUG -IN STRIPS AND /OR AUDIO/1V TRACKS SHALL BE RELOCATED BY THIS CONTRACTOR FROM EXISTING DISPLAY FIXTURES AS IDENTIFIED AND DIRECTED BY THE SHC PROJECT COORDINATOR. WHERE NEW EQUIPMENT IS REQUIRED, THIS CONTRACTOR SHALL FURNISH AND INSTALL NEW PLUG -IN STRIPS TO MATCH EXISTING. 19. NEW AND RELOCATION OF TELEPHONE /LOW VOLTAGE WIRING WILL BE BY OTHERS. EC SHALL PROVIDE OPENING AND CONDUIT STUB 3" IN TO ACCESSIBLE CEILING SPACE WITH PULL STRING. 20. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL WIRING AND CIRCUITS MATCHING RATING AND POWER REQUIREMENTS OF SPECIFIC ELECTRIFIED STORE FIXTURES, DEVICES AND EQUIPMENT NOT SHOWN ON THIS DRAWING BUT SHOWN AND INDICATED IN THE STORE PLANNING LAYOUT AS BEING RELOCATED OR NEW AS VERIFIED AND DIRECTED BY THE SHC PROJECT COORDINATOR. THIS EQUIPMENT SHALL INCLUDE BUT NOT LIMITED TO CHECKOUT POWER POLES, COOLERS, FREEZERS, PRICE SCANNERS, MOBILE CARTS, CASH REGISTERS, MULTI- OUTLET STRIPS, RECEPTACLES AND LUMINARIES. 21. ELECTRICAL CONTRACTOR SHALL UTILIZE PREVIOUS CIRCUITS AND PANELS FOR ALL RELOCATED EQUIPMENT SUCH AS COOLERS AND FREEZERS. ADJUST BRANCH FEEDER CONDUCTOR SIZES AS REQUIRED. ALL RELOCATED AND NEW RECEPTACLES SHALL MATCH EXISTING CONFIGURATION AND RATING OF EQUIPMENT. 22. CONTRACTOR SHALL RING OUT ALL CIRCUITS IN EXISTING PANELS AFFECTED BY THIS REFURBISHING. THIS CONTRACTOR SHALL REUSE EXISTING CIRCUITS VACATED BY THE REMOVAL OR RELOCATION OF DEPARTMENTAL FIXTURES. WHERE ADDITIONAL CIRCUITS ARE NEEDED REUSE AVAILABLE SPARE CIRCUITS OR PROVIDE NEW BREAKERS IN AVAILABLE SPACES. TAG ALL UNUSED CIRCUITS AS "SPARE ". REPLACE ALL INOPERATIVE OR DEFECTIVE CIRCUIT BREAKERS. TIGHTEN ALL CONNECTIONS. PROVIDE NEW TYPED UPDATED DIRECTORY FOR EACH AFFECTED EXISTING PANEL. KEYED NOTES SEE SHEET E -3 DETAIL 2 & 3 FOR WIRING SCHEMATICS. 10' -6" POWER /COMMUNICATIONS POLE WITH (2) 20A DUPLEXES AND DATA KNOCKOUTS (WIREMOLD #NP3DD106B) IF CEILING EXCEEDS 10' -6" PROVIDE ADDITIONAL BLANK POLE ( WIREMOLD #NP3K0106B) AND COUPLING ASSEMBLY ( WIREMOLD #NP301) FURNISHED BY CONTRACTOR. COMPLETE INSTALLATION BY ELECTRICAL CONTRACTOR. VERIFY LOW VOLTAGE NEEDS PRIOR TO ORDERING. REFER TO DETAIL 1 ON SHEET E -3. E.C. TO VERIFY LOCATION AFTER FIXTURE PLACEMENT AND WITH SEARS P.M. PRIOR TO INSTALLATION. BLANK POWER /COMMUNICATIONS POLE ( WIREMOLD #NP3DD106B) FURNISHED BY CONTRACTOR IF POWER POLE TO EXCEED 10' -0" PROVIDE EQUIPMENT LISTED IN KEY NOTE #2 ON THIS SHEET. COMPLETE INSTALLATION BY ELECTRICAL CONTRACTOR. E.C. TO VERIFY LOCATION AFTER FIXTURE PLACEMENT AND WITH SEARS P.M. PRIOR TO INSTALLATION. EC SHALL PROVIDE DUPLEX RECEPTACLE AT 9' -0" AFF ON COLUMN FOR VOICE BASE STATION, COORDINATE ANY DISCREPANCIES WITH PROJECT COORDINATOR. EC SHALL VERIFY /COORDINATE ELECTRICAL CONNECTION FOR NEW EXTERIOR SIGNAGE WITH SIGN CONTRACTORS AND PROJECT MANAGER, NEW SIGNAGE SHALL BE CIRCUITED LOCAL PANEL AND CONTROLLED BY NEW ASTRONOMICAL TIME CLOCK, THIS SHALL BE VERIFIED PRIOR TO BIDS. ELI} 0b3'1 r:. REVIEWED IEWED .I 0hH COMPLIANCE WITH NFPA 70 NEC SEP 2 8 2012 City o Tukwila BUILDING DIVISION 6 10 I ft IL La KEY PLAN SCALE: 1/64 " =1' -0" RECEIVED JUL 06 2012 PERMIT CENTER ISSUE DATE ISSUED FOR SCOPE OF WORK JANUARY 6, 2012 ISSUED FOR BID MAY 1, 2012 ISSUED FOR REVISIONS & PERMI7 JUNE 27, 2012 SEARS HOLDINGS OUTLET POWER PLAN z 0 V z_ J � n I- O 1 O CO LC) CO M N CO Project Arch.! Engineer: M.PELINI Drawn: J. FALLOS Checked: J. LINEGAR Date: OCTOBER 28, 2011 Sheet No: E -2 111 11111.11 !99 2 #12,1 #12G,3/4 "C TO PANEL "B" CKTS 4 LV WIRING BY OTHERS 2#12,1#12G,3/490 TO PANEL "B" CKTS 6 CONDUIT DROPS 2 #12,1 #12G,3/4 "C CK PANEL "B" � 11 CKT 16 4#12,1#12G,3/4"0 TO PANEL "B" CKTS 1,3,5 2#12,1#12G,3/4"C TO PANEL "B" CKT 16 3 #12,1 #12G,3/4 "0 TO PANEL "B" CKTS 7,9 J r I lAk 3- rI __r t, ) III PANEL "C" PANEL "D PANEL "E "- PANEL "F" PANEL "G' • PANEL "H PANEL "J" C -22 C -2 2 #12,1 #12G,3/4 "C TO PANEL "B CKTS 8 4 C -5 di REFRIGERATOR TESTING 0- J• • . L 11 II -23 I C -20 C -241 41110 C -25 111111 Co ej Il!',II At ' Awn 0 000 CO 0 rN O C -261 0111 2 #12,1 #12G,3/4 "C TO PANEL "B" CKT 16 11► C -101 C -11 111 U C -15, C -14 REFRIGERATOR TESTING 1111► C -271 [C:2C:29j Its 1111 II1Ia 0-13 -12 -.4 C -32� r C -33 (1111 LVIWIRING BYI OTHERS CONDUIt DROPS e 00 r N � 6 0 0 RANGE TESTING r 0 N c) d Co r Ch41' C�! O) CV Co CO 0 Cb I L IL∎ uji II;,11 I�� 11,`11 104 JANUARY 6, 2012 - W 1 r ®11 11 AISSUED FOR REVISIONS & PERMIT CV C�VCV. w: W L► Ii'i► ���, 57.01Nrerr440 - . �...... ._. - CO L -ANN N �.r: W W 111111 1 0,11 Ili 11 ,II El.- - 1.a - < 111.T� C 111i1a m' N LQ, LL 'Cr' e?; T' . C7 OIII IIwr r•-_ _In - 00._ r T r _ 411D .N..- 'r" '010 a ® _p _ 1 CC1 \ ........cY, co COOT 07 a) rN d' iP r;') r N r r 1 1 Cn 0 Oilrikb r.I .T - u_Li 1 • j ,- u_L� c�) r� GAS/ ELECTRIC DRYER TESTING r r ui c 4r (O r rr r 0) 0 CV N NN w N LL N or) N NN N 41 4 , u 011 , 1 T= _ M c') LL LL N M C r LO CD "4 M C? C? V A J -1 tio Co Ii N -i , 00 = V- r CV = 2 r N N 2 2 2 J -2 J -3 J -4 II H-7 H -8 H -9 H-10 J -5 J -6 WASHER TESTING F. J -7 J -8 J -9 H -11 H -12 H -13 R-14 H -15 J -10 J -11 J -12 J -13 J -14 ', J :15 J =1'6 J -=1W J----18 ;1==19 J :20 2 #12,1 #12G,3/4 "C l TO PANEL "B" CKTS14 J -22 J -24 J -25 J -26 J=27 J -28- DISH WASHER TESTING EC SHALL VERIFY THAT THERE ARE NO SPACE CONSTRAINTS ALONG THIS WALL WITH EXISTING EQUIPMENT AND NEW EQUIPMENT THAT IS TO BE INSTALLED, COORDINATE ISSUES WITH PROJECT MANAGER PRIOR TO INSTALLATION - _L:L..._ 3 #10,1 #10G,3/4 "C 1 TO PANEL "MDP" CKTS 26,28,30 II # 0 3 #10,1# 10G,3/4"0 TO PANEL "MDP" CKTS 32,34,36 SUB PANEL "B" PANEL "B" J� J -29 J-3 J -31 J-32 J -33 J -34 - CONDUIT DROPS 2 #12,1 #12G,3/4 "C TO PANEL "B" CKTS 12 2#12,1#12G,3/4'10 TO PANEL "B" CKTS 14 2#12,1#12G ,3/4"0 TO PANEL "B" CKT 16 1 PARTIAL POWER PLAN E -2.1/ SCALE: 1/8" = 11 -0" NORTH (- 2#12,1#12G,3/4"0 TO PANEL "B" CKTS 10 2 #12,1 #12G,3/4 "C TO PANEL "C" -CKT 40 7 2#12,1#12G,3/4"0 TO PANEL "C" CKT 38 2#6,1#6G,3/4110 TO PANEL "C" CKTS 34,36 4#12,1#12G,3/4110 TO PANEL "B" CKTS 25,27,29 1' } INCOMING METER SECTION PANEL "MDP" C-7.1 INCOMING METER SECTION PANEL "MDP" INCOMING POWER EQUIPMENT SCALE: 1/8" = 11 -0" KEYED NOTES EC SHALL FURNISH AND INSTALL (1) ONE DOUBLE DUPLEX RECEPTACLE WITH EACH DUPLEX ON A DEDICATED CIRCUIT FOR EVERY (2) TWO REFRIGERATOR, WASHER AND DISH WASHER TEST STATIONS, RECEPTACLE SHALL BE MOUNTED ABOVE WATER SUPPLY LINE, LABEL EACH RECEPTACLE WITH ITS CORRESPONDING PANEL AND CIRCUIT NUMBER, REFER TO ARCHITECTURAL WORKSTATION ELEVATIONS FOR MORE DETAIL. EC SHALL MOUNT ELECTRICAL PANEL ON UNISTRUT HALF WALL, EC SHALL ENSURE THAT SUFFICIENT BRACING IS PROVIDED FOR A SAFE AND SECURE INSTALLATION, COORDINATE WITH ARCHITECTURAL ELEVATIONS FOR MORE DETAIL. EC SHALL FURNISH AND INSTALL (1) ONE DOUBLE DUPLEX RECEPTACLE WITH EACH DUPLEX ON A DEDICATED CIRCUIT FOR EVERY (2) TWO RANGE TEST STATIONS AND (1) ONE 14 -50R PER EACH RANGE TEST STATION, RECEPTACLES SHALL BE MOUNTED ABOVE WATER SUPPLY LINE, LABEL EACH RECEPTACLE WITH ITS CORRESPONDING PANEL AND CIRCUIT NUMBER, REFER TO ARCHITECTURAL WORKSTATION ELEVATIONS FOR MORE DETAIL. EC SHALL FURNISH AND INSTALL (1) ONE DOUBLE DUPLEX RECEPTACLE WITH EACH DUPLEX ON A DEDICATED CIRCUIT FOR EVERY (2) TWO RANGE TEST STATIONS AND (1) ONE 14 -30R PER EACH RANGE TEST STATION, RECEPTACLES SHALL BE MOUNTED ABOVE WATER SUPPLY LINE, LABEL EACH RECEPTACLE WITH ITS CORRESPONDING PANEL AND CIRCUIT NUMBER, REFER TO ARCHITECTURAL WORKSTATION ELEVATIONS FOR MORE DETAIL. EC SHALL VERIFY ELECTRICAL CONNECTION REQUIREMENTS OF FORK TRUCK CHARGING STATION PRIOR TO INSTALLATION AND INSTALL PER MANUFACTURER REQUIREMENTS. EC SHALL PROVIDE DUPLEX RECEPTACLE AT 9' -0" AFF ON COLUMN FOR VOICE BASE STATION, COORDINATE ANY DISCREPANCIES WITH PROJECT COORDINATOR. EC SHALL VERIFY /COORDINATE FINAL LOCATION OF RECEPTACLE FOR ALARM PANELS WITH ALARM CONTRACTORS AND PROJECT MANAGER. 4 #12,1 #12G,3/4 "C TO PANEL "B" CKTS 11,13,15 MOUNT AT 4'AFF FOR ALARMS +18 "AFF DEDICATED CIRCUIT - FOR NETWORK CABINET 30A, 2 POLE, 120V HUBBELL - HBL93081G FOR UPS -.1.5 3#112, 1 #12G, 3/4 "0 TO PANEL "B" 517,19 10,1 #12G,3/4 "C TO PANEL "B" CKTS 21,23 MEZZANINE POWER PLAN SCALE: 1/8" 1, -0" REVIEWED KIN COMPLIANCE Q� N WITH SEP 2 8 2012 City of Tukwila BUILDING DIVISION KEY PLAN SCALE: 1/64 " =11 -0" EL I MIL ----"� {F TU1�1"�q. • � CEP '3 012 �EFtMIT CENTS ISSUE DATE ISSUED FOR SCOPE OF WORK JANUARY 6, 2012 ISSUED FOR BID MAY 1,2012 AISSUED FOR REVISIONS & PERMIT JUNE 27, 2012 ISSUED FOR PERMIT COMMENTS 4 SEPTEMBER 10, 2012 SEARS HOLDINGS c a) cD c .0) c W o U J CL ce 0 0- J I- 0_ Project Arch./ Engineer: M.PELINI Drawn: J. FALLOS Checked: J. LINEGAR Date: OCTOBER 28, 2011 Sheet No: E -2.1 DATA & COMMUNICATION COMPARTMENT. POWE COMPARTMENT. 3/4 "CONDUIT STUBBED INTO ACCESSIBLE CEILING SPACE FOR LOW VOLTAGE WIRING. PROVIDE BUSHING FOR CABLE PROTECTION. FACE OF POWE COMPARTMENT. —3/4 "CONDUIT TO JUNCTION BOX CIRCUITED AS SHOWN ON DRAWINGS. BOTTOM OF ROOF STEEL JOIST. SECURE POWER /COMMUNICATIONS POLE TO THE FLOOR PER MANUFACTURER'S RECOMMENDATIONS. POWER COMMUNICATION POLE SCALE: NOT TO SCALE NOTES: 1. SEE SALES AREA POWER FLOOR PLAN FOR LOCATION AND REQUIRED POWER. SECURE 1/2" FLEX FIRMLY TO BUILDING STEEL AND CONNECT TO J -BOX. RUN 2 #12 & 1#12 GROUND. 1/2" FLEX EMT CEILING HUBBELL #HBL5352 20A 125V DUPLEX RECEPTACLE FLUSH - MOUNTED IN CEILING SUPPORTED WITH BOX HANGER, "CADDY #512" (TYPICAL). CORD REEL FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR PURCHASED THRU GRAINGER #6YF67 BUILDING STEEL BEEM CLAMP (TYPICAL) SUPPORT CORD REEL TO BUILDING STEEL WITH (2) 1/2" THREADED ROD. E.C. TO VERIFY MATERIALS NEEDED. NUT LOCK WASHER LOCK WASHER NUT FRONT VIEW. RETRACTABLE CORD REEL SCALE: NOT TO SCALE NOTES: 1. SIMILAR FOR USE OVER FLEXIBLE COUNTERS. SEE SALES AREA POWER PLAN SHEET E -2 FOR LOCATION AND CIRCUITING SIDE VIEW SPLITTER IS CAPABLE OF PROVIDING 8 TV'S WITH 1080P HD SIGNALS OR 7 TV'S AND ANOTHER SPLITTER, THIS SPLITTER CAN BE CHAINED TO PROVID HD SIGNALS TO THE NECCESSARY QUANTITY TV'S. BLUE -RAY PLAYER / HD MEDIA SOURCE HDMI CABLE LENGTH TO BE DETERMINED IN FIELD AND ORDERED ACCORDINGLY f! t} f} A f! A f / ,f��L7/lI I I MONOPRICE Pow .4,0/1/OPi9 /CE' / Full HD 1080p HDMI Splitter87FHDM I -SP1OD 0 0 0 0 0 0 0 0 0 -- D Mom opal 0 $111111111 HDMI CABLES TELEVISIONS, LENGTH TO BE DETERMINED IN FIELD FRONT VIEW POWER SUPPLY TO TV 120V PLUGMOLD cTYPICAL WIRING SCHEME FOR HD SPLITTER SCALE: NOT TO SCALE SHELF HDMI CABLE LENGTH TO BE DETERMINED IN FIELD AND ORDERED ACCORDINGLY , -;;9 /E1d0/VG2,-1" Q ;'I ..��,g 'IIIIIIIIII 1. ILt/Oh! /:1LiV DfsY I� � IQI , 00 ® ®0 HDMI CABLES TO TELEVISIONS, LENGTH TO BE DETERMINED IN FIELD 12" O.C. (TYP.) v or POWER SUPPLY TO TV 120V PLUGMOLD OUTPUT TO BE USED FOR TV OR TO SUPPLY ANOTHER SPLITTER IF MORE THEN 15 TV'S ARE NEEDED El Ec Ec Ec FROM BLUE-RAYJ PLAYER / HD MEDIA SOURCE, LOCATION TO BE VERIFIED SHELF CONNECT TO TV VIA HDMI CABLE (TYP.) EC CONNECT TO TV VIA HDMI CABLE (TYP.) Ea EC Ec Ee FINISHED FLOOR 5" A.F.F. 12" A.F.F. 56" A.F.F. 60" A.F.F. 64" A.F.F. HDMI CABLING (LENGTH TO BE DETERMINED IN FEILD, TYPICAL OF ALL) BLUE -RAY PLAYER TYPICAL "PLUGMOLD" WIRING SCHEME @ TV WALL ELEVATION "A" SCALE: NOT TO SCALE NOTE: G.0 TO PROVIDE PLUGMOLD FOR WALL OF EYES AND SINGLE CONDUIT AND J -BOX FOR AV OUTLET. TYPICAL CIRCUITING REQUIREMENTS INCLUDE A MIN. AMPACITY ALLOWANCE OF 600W PER 8 LINEAR FEET. THIS REQUIREMENT IN CONJUNCTION WITH 2 -CKT. WALL MOUNTED PLUG IN MULTI OUTLET STRIPS (WIREMOLD MULTI CIRCUIT #24GBA612) SHALL BE GRAY IN COLOR. IF THE LENGTH OF PLUGMOLD IS LESS THAN 23' USE (WIREMOLD SINGLE CIRCUIT #24GB612). HD SPLITTER HD SPLITTER DISPLAY TV (TYPICAL) HDMI CABLING (LENGTH TO BE DETERMINED IN FEILD, TYPICAL OF ALL) MULTI - OUTLET PLUG STRIP ,J SHELF Ns- 51 -411 TYPICAL "PLUGMOLD" WIRING SCHEME @ TV WALL ELEVATION "B" SCALE: NOT TO SCALE 5" 1' — GENERAL NOTES 1 GC TO INSTALL NV DISTRIBUTION SYSTEM INCLUDING ALL NECESSARY EQUIPMENT. PROVIDE LABOR, APPLICABLE TAXES, PERMITS, AND OTHER RELATED SERVICES AS INDICATED ON DRAWINGS AND AS INTENDED VIA APPLICABLE SCOPE OF WORK. 2. GC WILL COORDINATE THE AN SYSTEM INSTALLATION TIME AND THE STORE PHASING SCHEDULE WITH THE SEARS PROJECT MANAGER. 3 INSTALL THE EQUIPMENT LISTED, AS PER THE ATTACHED WIRING DIAGRAMS. 4 SEARS WILL PROVIDE ALL CORRESPONDING PATCH CABLING BETWEEN TV SETS AND HD SPLITTER. THE ANAL CONNECTIONS WILL BE DONE BY OTHERS WHEN MERCHANDISE ARRIVES. 5. SEARS WILL PROVIDE THE FOLLOWING LIST OF MATERIALS FOR INSTALLATION: QUANTITIES WILL CHANGE FOR EACH JOB BASED ON THE FINAL FIXTURE PLAN. AN ACCURATE TAKEOFF IS REQUIRED. - (16) MONOPRICE.COM 24AWG CL2 HIGH SPEED HDMI CABLE WITH NET JACKET MALE TO MALE OR EQUAL ITEM #4158 - (1) BLUE -RAY PLAYER -(1) MONOPRICE.COM HDMI SPLITTER MODEL TBD ITEM #6194 6. ALL CABLE, EXCEPT FROM PLUGMOLD TO TELEVISION, TO BE CONCEALED ABOVE THE CEILING, WITHIN WALL CAVITY IF ALLOWED BY CODE, IN CONCEALED CONDUIT IF REQUIRED BY CODE AND WITHIN THE PLUGMOLD FIXTURE MOUNTED BEHIND THE TELEVISIONS. REVIEWED :FON COMPLIANCE WITH NFPA70 -NEC SEP 2 8 2012 C o .TukwiIa BUILDING DIVISION RECEIVED 3 �"' JUL 06 2012 PERMIT CENTER ISSUE DATE ISSUED FOR SCOPE OF WORK JANUARY 8, 2012 ISSUED FOR BID MAY 1, 2012 ISSUED FOR REVISIONS & PERMIT JUNE 27, 2012 SEARS HOLDINGS Project Arch./ Engineer. M.PELINI Drawn: J. FALLOS Checked: J. LINEGAR Date: OCTOBER 28, 2011 Sheet No: E -3 PANEL SCHEDULE NAME PLATE : NT 120/208 VOLT BUSS 11200 1200 AMP. MAIN _ B_ RKR 3 PHASE 4 -WIRE 142 CKT BRANCHES CIRCUIT BREAKER BRKR TYPE BOLT -ON MOUNTING SURFACE A.I.C: 122K CKT# VA SERVES APPLIANCE: _ _SERVES L GHTIN_G SERVES RECEPTACLES: SERVES MISCELLANEOUS MS 4MPS LOAD (KVA) 1__.....1 1... ..1_ -.. I....,1__......... POLE A B C LOCATION: I S/E CORNER OF SPACE I PANEL LOAD :ENTRANCE. BOTTOM FED FROM:1 UTILITY __._.. _..._FEEDER.._._ -_.. SIZE: 1000 AMP _ SETS: IWIRE1 600MM THH COND.: 3' I I A- CONNECTED LOAD - DEMAND LOAD L DEMAND AMPS 'MPS ......._.. POLE TRACK LIGHTING SERVES MOTOR SERVES HEATING SPARE / SPACE ._L....... i ..,.i.... _i.. _..- VA CKT# NT 3 6 7 9 11 13 16 17 19 10301 10301 1' PANEL'S' MS MS MS MS 10400 2 100/3 x� x4 ®IIILs f�%►t PANEL'F' 21 23 25 27 29 31 33 35 37 39 41... 8 „ 8468 8486 PANEL '1-1* SPACE SPACE SPACE SPACE SPACE SPACE SPACE MS MS MS MS MS MS SPACE SPACE 4 SUB TTL 3 S S S S S S 150/3 MS MS MS MS MS M __. PANEL C' 10400 11 A =In 7880 Ai 7680 ktatloi 10608 10008 2138 2136 30 FORK TRUCK CHARGER 2136 82.1 82,1 82.1 DEMAND FACTORS '. 8141 1st ,OKVA AEC ' IP 1.0 0.00 BAL. REC.'S .5 Ct1t LARGES Gro rM R TTL MOTOR LOAD # OF . APPLIANCES. L LOAD OAD TTL 7TC LF OF TRACK =: ADD. TRACK LOAD PER NEC:' 220 :43(B) 1 BRKR NOTES: € 1 = BREAKER LOCK 2 = GFCI BREAKER 3 = SHUNT TRIP 4 TIME CONTROL 5 = HANDLE TIE 1 PANEL SCHEDULE ... 1, NAME PLATE I "F" 120/208 3- BUSS 200 PHASE, TYPE A.I.C. 1 VOLT 225 AMP. MAIN LUG 4 -WIRE 42 CKT BREAKER. BOLTON SURFACE 22K j _ _• LOCATION: 1...- _...1. ENTRANCE: FED FROM: DRYER TEST AREA 1....... .... TOP 1 I PANEL'MDP' PANEL LOAD BRANCHES BRKR MOUNTING: _ FEEDER SIZE:I 150 AMP I i SETS: 1 wIRE:I COND.) 2/0 THHN CU 2' _ 52.42 ; -4.07 I 4.72 A - CONNECTED A - DEMAND L DEMAND AMPS . I LOAD LOAD I L _ SIZE: SETS: FEEDER 266-AMP 1 IWIRE:1 250MCM COND. i THHN C 2-1/2' � / LOAD LOAD ._....,,. . A L R_ MS ( .,_ ».I._..._..,..__�..... I 1__.,..... { ,.....__,._..i__.._,.,..... CKT NT CKT #I S ERVE S APPLIANCE: A SERVES LIGHTING L SERVES RECEPTACLES R SERVES MISCELLANEOUS MS I . LIGHTING A L R I T M H S TRACK LIGHTING ( SERVES MOTOR SERVES HEATING _ SPARE /SPACE I , , CKT# NT AMPS/ POLE LOAD (KVA) A B C AMPS/ POLE NT 1 MS GAS DRYER 110V RECEPT S 0/1 0.0 • < 20/1 S GAS DRYER 110V RECEPT 1100 2 A 3 1 2184 ELECTRIC DRYER RECEPT A '12 20/1 4.4 .;.;` 30/ A ELECTRIC DRYER RECEPT 2184 A A 3 5 184 A 20/1 •4.4 • 1 ---- 20/1 fl 2184 1000 4 7 2184 ELECTRIC DRYER RECEPT A A '/2 R 20/1 z,7, 2 30/2 • ELECTRIC DRYER RECEPT 2184 2184 ORS REPAIR 1000 9 rs,s Min 7 ' 44 ,y 20/ 1 0.8 11 �,- GAS DRYER 110V RECEPT S '/1 =F =' 0.0 20/1 1 GAS DRYER 110V RECEPT 9 180 MANAGERS OFFICE 13 20/1 GAS DRYER 110V RECEPT S "/1 0.0 t . a . 20/1 GAS DRYER 110V RECEPT 10 0 ?: 4.4 30/ 11 15 17 184 ELECTRIC DRYER RECEPT A A '/2 : 4.4 `I:z1",11 <. 30/2 ( ELECTRIC DRYER RECEPT 2184 2184 • 400 1 ,, "., ELECTRIC DRYER RECEPT 4.4 13 800 19 2184 ELECTRIC DRYER RECEPT A A /2 4.4 ' #' *S 30/2 1 ELECTRIC DRYER RECEPT 2184 2184 1j1 16 21 15 800 4 4�` #t(`u,a: k 23 � GAS DRYER 1 10V RECEPT S /1 VOICE BASE STATION 400 0 0 2011' GAS DRYER 110V RECEPT 17 111 30MPUTER RM NETWORK CAB 2 5 20/1 GAS DRYER 10V RECEPT S A RYE 1 ' 1 ! 0 0 •r�, ,. , :a, ,..: ,..rE. 20 1 / ,� GAS DRYER 110V RECEPT 18 +: 30/ A 27 29 184 ELECTRIC DRYER,RECEPT A A .3 2 1 0/ 4.4 ass` 4.4 :,30/2 A ELECTRIC DRYER RECEPT 2184 �' 1500 31 33 184 ELECTRIC DRYER RECEPT_ A A 3 2080 4.4` a ; 30/2 �� ELECTRIC DRYER RECEPT_ 2184 2184 5.1 20/1 35 • GAS DRYER 110V RECEPT S 2 24 , 0,0 20/1 GAS DRYER 110V RECEPT R "* 37 L SPACE S 20/1 0.0 LIGHTING 1500 �.„' �" �'•- ..., 38 800 39 �1.1"-i_ .....' 2.3 M 0.0 20/1 S -n SPACE 1500 40 _ 28.2 41 AL SPACE S 800 TV REPAIR R '0 S SPACE s, -; _:' 42 L LIGHTING 1500 28 30 SUB TTL i 3.1 26.2 13.1 20/1 is e ;z f 2.3 20/1 L LIGHTING 1500 30 ,...,... ,...,.._.,.._..,.., -3 ._,., ,._.J___. 1 31 768 a _ 220.42 220 44 _: 430 24; , 0.2s;. ,a 4 2 ! ' € 20. 66 ! 20 43( 8) 15 !aa .$,� ,' x>, , M 1 768 DEMAND FACTORS wf PER NEC;: 33 I BRKR NOTES: - 1 - BREAKER 2 = G C i BREAKER }3 = SHUNT 4 = TIME CONTROL =HANDLE ............... LOCK L TRIP TIE .. 1 K 1 1 ,,,...•,_.._.....,._,.._.._. _ ....... .. ._..... ...,,.._.,,... ' I . .._ ,,..,_. FUTURE FAN 0.00' 0.00' 0.00:'BAL. 0' 34,07 LTN 1 ylst 10KVA REC 1. REC.'S 0� .6 5T LMQE MOTR TTL MOTOR LOAD 41OF APPLIANCES. TL APL. LOAD ..,'" :OF RACK TTL LF T TRACK LOAD 0 O m -' °` , ->; , a KVA' "_' lTS r 0.42 .( 220.44 , 450:14 „- •430.26 : 430.285 2 2056 '....... 220.43(8) . ,,.. K ; s _ 768 ................ .. .... ...... FUTURE FAN M M M 20/3 I • 'ADD: 1.5 ...... 20/3 M � M M .. ....................... _ FUTURE FAN 768 1 1 1 I I 30 I PANEL SCHEDULE ... 1, -- .._._s__.1 _ _....._L ............._..._. NAME PLATE 1 T : 1..............1.,_ _._._............... ` ._3.__ "B" existing ! I 1 € 1 . _._..`........_1....__1...._..1 1 ._...1......_.._...._L......... 1 I 1 BUSS 200 TYPE A.I.C: 120/208 3 BRANCHES BRKRTYPE: MOUNTING_ _.. BUSS .?9,9_. PHASE AI „_._,.......� 'BOLT C � VOLT 225 M AMP 4 WIR CIRCUIT -ON SURFACE 22K _ .. ....,»4,..µ.,.,.,Y...._..,,,.._ I LUG A N 1 E 42 CK T BREAKERS LOCATION: ENT CE RAN J FED FROM: NEAR PRS OFFICES E .1 TOP 1 PANEL PANEL _ "_R_�. 36.76 !KVA 30.90 IKVA 86,91 1TTL I ,.,.... ,_I.,.. _ LOAD 4 .J[ - CONNECTED - DEMAND DEM_AND AMPS µ,,.....1_. _II-- 1. L _ SIZE: SETS: FEEDER 266-AMP 1 IWIRE:1 250MCM COND. i THHN C 2-1/2' � / LOAD LOAD ._....,,. . A L R_ MS ( .,_ ».I._..._..,..__�..... I 1__.,..... { ,.....__,._..i__.._,.,..... CKT j _ Ni-- CKT # _ µVA SERVES APPLIANCE: SERVES SERVES RECEPTACLES: SERVES MISCELLANEOUS: _ 1 LIGHTING A L R I TRACK LIGHTING SERVES MOTOR SERVES HEATING SPARE SPACE / T M 1 H TRACK LIGHTING SERV S MOTOR E SERVES HEATING SPARE /SPACE 1'"`1 1 ' VA CKT# NT MS AMPS/ POLE LOAD A (KVA)._ B C AMPS/ POLE S T `'B €1 5 1 1100 REFRIGERATOR A 20/1 2,1 .x�l` ;. 20/1 R TREADMILL REPAIR 1000 2 30 ' A A 3 200 PRINTER R 20/1 2184 A 1 ---- 20/1 fl MATTRESS SANITATION 1000 4 0/2 4.4 5 800 COPIER / FAX R 20/1 z,7, 2 7.T 1.6 20/1 R ORS REPAIR 1000 6 rs,s Min 7 400 MANAGERS OFFICE R 20/ 1 0.8 S9 �,- 20/ 1 R ORS COMPUTER R 400 8 10 0 0 9 180 MANAGERS OFFICE R 20/1 k 1.2 x � r+ 20/1 R PRS REPAIR 1000 10 0 ?: 4.4 30/ 11 11 400 TRAINING RM R 20/1 20/1 2184 ELECTRIC DRYER RECEPT 2184 A 0.8 20/1 R PRS COMPUTER 400 12 ELECTRIC DRYER RECEPT 2184 2184 13 800 OFFICE R 20/1 1.2 4,1' ' #' 20/1 R APPLIANCE TEST COMPUTER 400 14 16 s 1 15 800 OFFICE R 20/7 k 1.2 MO 20/1 R VOICE BASE STATION 400 16 ' c 0 2 / A 17 200 30MPUTER RM NETWORK CAB R 20/1 '� , n 1.7 20/1 L LIGHTING 1500 18 +: 30/ A 19 200 COMPUTER ROOM ALARMS R 2 1 0/ 1 1.7 20/ 1 L LIGHTING 1500 20 GAS DRYER 110V RECEPT 1200 • EFRIGERATOR TEST STATI O N 21 2080 COMPUTER ROOM SERVER R 30/2 0.0 3 6 1 " 20/1 L LIGHTING 1500 22 24 ���11 23 2080 A R "* 20/1 b 3.e 20/1 L LIGHTING 1500 24 28 i' ' 25 800 TV R EPAI R - R 20/1 2.3 4� 1.4 20/1 L LIGHTING 1500 26 _ 28.2 13. 27 800 TV REPAIR R 20/1 20/1 2.3 s, -; _:' 20/1 L LIGHTING 1500 28 30 25 29 800 TV REPAIR R 20/1 is e ;z f 2.3 20/1 L LIGHTING 1500 30 ,...,... ,...,.._.,.._..,.., -3 ._,., ,._.J___. 1 31 768 NG 1 0 LT t? 1at10K AREG 10 V @ BAL. REG:S it3, ,.6:''` t�IRGEST,MOTOR MOTOR LOAD # APPLIANCES ANCES U TTL APL. LOAD "�. T OF7 A _ T LLF ADD:' TRACK LOAD' M 220.42 220 44 _: 430 24; , 0.2s;. ,a 4 2 ! ' € 20. 66 ! 20 43( 8) 15 !aa .$,� ,' x>, , M 1 768 32 34 A 33 768 FUTURE FAN M M .9./. ' 1.6 , ,,.f 1.5 20/3 M M FUTURE FAN 768 768 34 36 36 20/1 35 760 1378 37 768 ................ .. .... ...... FUTURE FAN M M M 20/3 ;�,.y'', ® 1.5 ...... 20/3 M � M M .. ....................... _ FUTURE FAN 768 38 30 1378 39 768 768 40 2.1 SPACE P 41 768 768 42 672 40 3.0 „_.....,._ 41 SUB TTL LIGHTING L 11,2 Ti. 5 117.. 3,1 2.1 S M j., ,,_ „e.,_. j _....,,,_,,,, 42 _..,,. A PRS REPAIR 1200 38 ( SUB TTL 1 9,5 1 8,7 8,7 1,._.,... S 0.0 1 2 4n ? 20/1 ....., PRS REPAIR _..µ..ms. _.. . ,..__ ................._.:_.._.. _ t, ........ .......:,._,....1...., { 1 1 , , , � � � " :DEMAND "FACTORS <•,,. -. • '_ E NEC :i PER N ------ BRKR NOTES: 1 = BREAKER LOCK = GFCI BREAKER 3 = S UN TT RIP 4 = T I ME CONTROL 5 - HANDLE TIE .___._,.__,.__.._ _ "_.. »• -,.,. G '70 10.50 00 'rlai 10KVA 'RE =2 ,97 'B :R EG. !' S ,5 ' `ALES M 0 R 3':S 6,33 TTL MOTOR LOAD =: ,,,, # OFAPPUANCES i 1 >TTLAPL LD AD TTLiFOFTRACK ADO_TRACKLOAD':' ,. UNITS' 2 0:42 .REA`,LTN 2 ' 220 :44' 430.24' . 43025 ` , _ :430 8..: : 220 56 22043(3) ; LF _.._, 11 02 -LTNG @ to ' " '+ 10.00 let 10KVA REG. Q 1 0 0.40 BAL. REC.'S @ 5 LARGEST MOTOR. 3 616 TTL MOTOR I: #OF.APPLIANCES AD 1 TTLAPL LOAD 1 TTL LFOF TRACK = ADD, TRACK LOAD 1 11 1 I 1 1 I I _...._., 15.6 1 1 1 1 1 1 1 PANEL SCHEDULE 1,...7_...........1_ .L._?.. .. NAME PLATE ......_L._....'.. _....._.s.......s. : ; ._..:..._..L..._._........._.. _......._ ........a._....1._.....1....... " " G BRANCHES: 120/208 3-PHASE, BRKR MOUNTING BUSS 200 TYPE A.I.C: 1VOLT 225 1AMP. MAIN LUG -1-4-WIRE 1_42 CKT -1 t.CIRCUIT BREAKER: BOLTON ISURFACE 122K P i , J.1111M LOCATION: ENTRANCE: FED FROM: DRYER TEST AREA TOP PANEL'MDP' __Li...._ 26 25 72.11 PANEL LOAD r , I SIZE SETS FEEDER 150 AMP 1 WIRE 2/0 COND., , _ THHN CU 2' 120/208 52.42 A CONNECTED 34 07 A DEMAND 94.72 L DEMAND AMPS LOAD LOAD NT CKT# VA SERVES APPLIANCE: SERVES LIGHTING SERVES RECEPTACLES: NS SERVES MISCELLAEOU I , I _.,._. ....... A L R_ MS _..._., .,- .,.,.- _ NT CKT ,. •' SERVES APPLIANCE: A SERVES LIGHTING: L SERVES RECEPTACLES: R MISCELLANEOUS: S SERVES MISCELLANEO M - - -. - - AMPS/ POLE T " M H S TRACK LIGHTING SERVES MOTOR SERVES HEATING SPARE SPACE / 1000 VENDING MACHINE CKT# NT _ MP • MPS POLE LOAD • A A (KVA). B C / POLE R GAS DRYER 110V RECEPT 9 20/1 0. `'B €1 5 =:: 20/ S GAS DRYER 110V RECEPT R 1[ 2 `:I 1,4 2184 ELECTRIC DRYER RECEPT A k 0/2 1 4 4 "`: 30 ' A A ELECTRIC DRYER RECEPT °_- .,-... ....,_ _,.....,..,,_...._..._.__ _-•.-„ 2184 2184 �+ SEASONAL CHECK OUT R 2184 A 1 ---- 1 0 4.4 R SOLUTION CENTER 2184 ELECTRIC DRYER RECEPT A 0/2 4.4 -+ ' +: 30/ A A ELECTRIC DRYER RECEPT 2184 2184 0 s .;' `,��' 2184 A P,.,e CORD REEL 4.4 rs,s Min GAS DRYER 110V RECEPT S '0/l ....?. `: ` r o.o 20/ 1 S GAS DRYER 110V RECEPT ,S!. 20/1 R WALL OF EYES - GAS DRYER 110V RECEPT S''0Jl 10 0 0 AMPS/ 11 20/1 S GAS DRYER 110V RECEPT 20/1 4 20/1 2.4 2.2 2184 ELECTRIC DRYER RECEPT A 2184 A 1 s0 /2 r ,`, 4.4 0 ?: 4.4 30/ 11 A A ELECTRIC DRYER RECEPT 2184 2184 8 S 20/1 2184 ELECTRIC DRYER RECEPT 2184 A � 4.4 ': 1 1,..<,` 4.4 „�."'.; 30/ A A ELECTRIC DRYER RECEPT 2184 2184 ' r2 15 , GAS DRYER 110V RECEPT S 1.0/1 y- II -0 0.0 20/' 3 GAS DRYER 110V RECEPT REFRRIG. CHECKOUT ECR 400 16 s 1 GAS DRYER 110V RECEPT S r 0/1 0.0 vy ` ; "- 20/1 S GAS DRYER 110V RECEPT 0.0 6 S SPARE 2184 ELECTRIC DRYE ECE T A 1 4 E ECT R R P A ' c 0 2 / A 4 4 4 4 30 � / A A ELECTRIC DRYER RECEPT 8 21 4 2184 z •0 r y F2184 2184 ELECTRIC DRYER RECEPT A 2184 A s0 /2 a maw,SE. 4.4 +: 30/ A A A ELECTRIC DRYER RECEPT 2184 2184 •4 S 20/1 GAS DRYER 110V RECEPT S • 0/1 „ •.? :r 0.0 20/11 S GAS DRYER 110V RECEPT 1200 • EFRIGERATOR TEST STATI O N 6 23 4 SPACE S S 0.0 ' „x,'�,M 0.0 \..4118,, ,ih, :4. . .. 4 38 24 ���11 \11I '!4�'! �'"�"_/ 25 A 0.0 "* 20/1 0.0 ©AR SPACE - 40 S 41 Ak. SPACE S 28 i' ' EFRIGERATOR TEST STATION 0,0 1378 3 SPACE 20/1 42 1.4 g____.... --- _. ��Sl1B TTL ,,.., SPARE 3.1 _ 28.2 13. S 29 1378 LIGHTING L 20/1 ,,,,V,': ' -. 1.4 1 i S SPARE c 30 25 1 1 1 I 1378 LIGHTING L 20/1 2.1 DEMAND FACTORS' '''' ' EFRIGERATOR TEST STATION PER NEC:' I BRKR NOTES: 4 4 672 ,...,... ,...,.._.,.._..,.., -3 ._,., ,._.J___. 1 A 0.00 0 0 0 000 % 0TTL e 34.0 NG 1 0 LT t? 1at10K AREG 10 V @ BAL. REG:S it3, ,.6:''` t�IRGEST,MOTOR MOTOR LOAD # APPLIANCES ANCES U TTL APL. LOAD "�. T OF7 A _ T LLF ADD:' TRACK LOAD' , , : KVA . !':. NITS � 220.42 220 44 _: 430 24; , 0.2s;. ,a 4 2 ! ' € 20. 66 ! 20 43( 8) 1 BREAKER LOCK 2 GFCI BREAKER 3 =SHUNT TRIP 4 = TIME CONTROL 6 HANDLE TIE I ........... ..........._........---......._ _,_,... ......... j ACK , LF , 20/3 1 I l 1 PANEL SCHEDULE NAME PLATE "A" existing 3RANCHES__ICIRCUIT 120/208 BUSS 225 3-PHASE BRKR TYPE MOUNTING: A.I.C: (VOLT .AA 225 TAMP MAIN LUG 4-WIRE 42 CKT BREAKER• BBOLT ON ••.IFLUSH. 122K l LOCATION 1_ 1 ENTRANCE: FED FROM: I 18340 SALES FLOOR ' TOP UTILITY J.1111M PANEL LOAD 1 „L „_„_____. KVA_ CONNECTED LOAD KVA DEMAND LOAD DEMAND AMPS 11 1 t ..1,.._ _ • __Li...._ 26 25 72.11 86 94. fTTL _ _ SIZE: SETS: - FEEDER _., __ __ AMP _. _ __ __ ,.,_ ,___ 1 . {WIRE... 4/0 THHN CU COND 2-1/2' _ AREA 120/208 I 100 AMP. MAIN LUG NT CKT# VA SERVES APPLIANCE: SERVES LIGHTING SERVES RECEPTACLES: NS SERVES MISCELLAEOU I , I _.,._. ....... A L R_ MS _..._., .,- .,.,.- T M H S TRACK LIGHTING SERVES MOTOR / SERVES HEATING SPARE SPACE 1 . ;... ... 1..• ....1 VA CKT# NT AMPS/ POLE LOAD (KVA) A =B C AMPS/ POLE BRANCHES: 1 1000 VENDING MACHINE R 20/1 1.4 ,,,, ", .,.t 20/1 R LAUNDRY CHECK OUT ECR 400 2 SURFACE 22K 22K 3 1000 VENDING MACHINE R 20/1 `:I 1,4 31.20 86.74 20/1 R LAUNDRY CHECK OUT ECR 400 4 RECPT ___ 5 400 SEASONAL CHECK OUT R 20/1 1 ---- 1 0 20/1 R SOLUTION CENTER 800 6 __...__. ME 7 1600 SEASONAL CORD REEL R 20/1 3.2 s .;' `,��' 20/1 R CORD REEL 1600 8 Min SERVES MOTOR 8 200 . VOICE BASE STATION R 20/1 ct 1.4 ,S!. 20/1 R WALL OF EYES - 1200 10 POLE AMPS/ 11 1000 ELECTRIC WATER COOLER A 20/1 n 20/1 2.4 2.2 20/1 R WALL OF EYES 1200 12 2 POLE 13 1200 •E AGE A OR TEST STATION 1 FR R T SPARE S 20/1 0.8 I i' z., s, -! 20/1 R REFRRIG. CHECKOUT ECR 800 14 1200 - EFRIGERATOR TEST STATION A 15 , SPARE S 20/1 +! 0.4 6 20/1 R REFRRIG. CHECKOUT ECR 400 16 s 1 A 17 A SPARE S 20/1 �, r 0 0.0 20/1 S SPARE kit << 1„ 18 A • EFRIGERATOR TEST STATION 19 10 SPARE S 20/1 0.0 r y , • 20/1 S SPARE EFRIGERATOR TEST STATION 20 12 A 21 1200 • EFRIGERATOR TEST STATION SPARE S 20/1 - i 0.0 -: 20/1 S SPARE 28 22 1200 • EFRIGERATOR TEST STATI O N A 23 4 SPARE S 20/1 s u ^; 0.0 20/1 S SPARE A 24 20/1 2.4 25 A SPARE S 20/1 0.0 19 - 20/1 S SPARE t f'�u'` 28 A EFRIGERATOR TEST STATION 27 1378 LIGHTING L 20/1 r '* 1.4 : 20/1 'S SPARE • EFRIGERATOR TEST STATION 28 22 S 29 1378 LIGHTING L 20/1 ,,,,V,': ' -. 1.4 20/1 S SPARE c 30 25 1200'EFRIGERATOR TEST STATION 31 1378 LIGHTING L 20/1 2.1 A ' EFRIGERATOR TEST STATION 1200 M 4 4 672 32 1200 • EFRIGERATOR TEST STATION A 33 1378 LIGHTING L 20/1 k " 2.1 , 20/3 M FUTURE FAN 672 34 A 20/1 35 1378 LIGHTING L 20/1 ',,•I -'.! 2.1 A M 31 672 36 20/1 2.4 37 1378 LIGHTING L 20/1 2.1 =.,'x'- _...vj;r 0 M 1200 • EFRIGERATOR TEST STATION 672 38 r 4.2 30 1378 LIGHTING L 20/1 ' :, . 2.1 SPACE P 20/3 M FUTURE FAN 672 40 3.0 SPACE 41 1378 LIGHTING L 20/1 '' [ 2.1 S M 1.2 672 42 20/1 A PRS REPAIR 1200 38 ( SUB TTL 1 9,5 1 8,7 8,7 1,._.,... S 0.0 1 2 4n ? 20/1 ....., PRS REPAIR 1200 40 S 41 SPACE 8 1 J. I BRKR NOTES 1 = BREAKER I2 = GFCI BREAKER 3 SHUNT f4 = TIME CONTROL" ;5 _ HANDLE __.- .._..... - t .,z,,. 0.0 S _ L I 1 I 1 -�� DEMAND FACTORS PER NEC LOCK TRIP TIE _ .._.._ _.._, 11 02 -LTNG @ to ' " '+ 10.00 let 10KVA REG. Q 1 0 0.40 BAL. REC.'S @ 5 LARGEST MOTOR. 3 616 TTL MOTOR I: #OF.APPLIANCES AD 1 TTLAPL LOAD 1 TTL LFOF TRACK = ADD, TRACK LOAD 220 42 20.44 430'14 2 KVA 430 25 44024,. 1 'UNIr3 3� 220.55 220 43(8) I -. ,- .. -___. _...._., 15.6 I; 1... 1 1 1 1 1 _ -...__ PANEL SCHEDULE ( I ! 1 1 1 1 t 1 1 I I i 1 1 1 ■ 4 i 1 I 1 NAME PLATE : BRANCHES: NAME PLATE __I_ 1 -- 'r_.�.___.._ NAE PLATE -7-1-1M7- J.1111M __ IIIIIIIIIIIIIIBIIIIIIIIIISMIINIIIINIIIIUMIIIIIIIIIIMIIIIII 120/208 BUSS VOLT 100 LOAD LOAD __ LOCATION: 7 I 1 REFRIG. TEST r T AREA 120/208 PANEL LOAD 100 AMP. MAIN LUG WASHER TEST AREA ENTRANCE: TOP 225 __._.._.__._____._____._. AMP. MAIN LUG 4 -WIRE 142 CKT d CIRCUIT BREAKER, _..._., 3 -PHASE ,__L__ . TOP PANEL 'MOP' FEEDER A L R MS FED FROM: PANEL "M11/12' PANEL LOAD BRANCHES: CIRCUIT BREAKER BRANCHES: FEEDER BOLT -ON ME IIIIIIIIII BRKR TYPE: BOLT -ON �, 2/0 THHN CU SIZE: 150 AMP 1 48.00 KVA - CONNECTED LOAD ` ": MOUNTING: A.I.C: ,-- SURFACE 22K 22K 2 COND. 2' S ET S 11111111111111111.11111111111111111111. 1 W I RE: COND. i 2 0 TH H CU 2' 31.20 86.74 8 0 KVA - DEMAND TTL DEMAND LOAD______ AMPS __ -_-. RECPT ___ -_ _ _.__ I A ---- __._._ _ __. __. _ �_____..___ 3000 ELECT. RANGE RECPT __...__. ME SERVES APPLIANCE: A I LOAD A KVA �� 111 TRACK LIGHTING M SERVES MOTOR al SERVES LIGHTING: L 8 0 Min SERVES MOTOR A NT SU C # CKT #10M11111111111111111111111111111111 SERVES RECEPTACLES: SERVES MISCELLANEOUS: R MS AMPS/ POLE AMPS T 1 1 1 1 SERVES HEATING SPARE SPACE 20/ / s GAS RANGE 110Y RECEPT 1440 SERVES MISCELLANEOUS: POLE AMPS/ �_ -NT S 1 1200 • EFRIGERATOR TEST STATION A 20/1 2.4 Sie „ ": r r` 20/1 A • EFRIGERATOR TEST STATION 1200 2 POLE 3 1200 •E AGE A OR TEST STATION 1 FR R T A 2D 1 / 2 4 ,�! x *•" 20 1 / A • EFRIGERATOR TEST STATION 1200 4 �;?: 8 1200 - EFRIGERATOR TEST STATION A 20/1 I• .t ' , 2.4 20/1 A • EFRIGERATOR TEST STATION 1200 6 A 7 1200 •EF IOERATOR TEST STATION 1 R A 20 1 2 4 / s 1 A 20 1 / A • EFRIGERATOR TEST STATION 1200 8 5 0 1200 • GE A OR TEST STATION 12 EFRI R T T I A 20 1 / 2 4 kit << 1„ 20 1 / A • EFRIGERATOR TEST STATION 1200 10 6 11 1200 • EFRIGERATOR TEST STATION A 20/1 Ci , • 2.4 20/1 A EFRIGERATOR TEST STATION 1200 12 A 13 1200 • EFRIGERATOR TEST STATION A 20/1 2.4 is °: 20/1 A • EFRIGERATOR TEST STATION 1200 14 28 18 1200 • EFRIGERATOR TEST STATI O N A 20 1 4 10 20/1 A 'EFRIGERA O R T EST STAT I ON 1200 16 A 17 1200 • EFRIGERATOR TEST STATION A 20/1 ;t t 20/1 2.4 20/1 A • EFRIGERATOR TEST STATION 1200 18 13 19 1200 • EFRIGERATOR TEST STATION A 20/1 2.4 s t f'�u'` 20/1 A EFRIGERATOR TEST STATION 1200 20 14 21 1200 • EFRIGERATOR TEST STATION A 20/1 2.4 ,. i,.�l... 20/1 A • EFRIGERATOR TEST STATION 1200 22 S 23 1200•EFRIGERATOR TEST STATION A 20/1 'iii. +'1 2.4 20/1 A -EFRIGERATOR TEST STATION 1200 24 c 4.4 25 1200'EFRIGERATOR TEST STATION A 20/1 2.4 f ;ry 3 20/1 A ' EFRIGERATOR TEST STATION 1200 26 4 4 t 27 1200 • EFRIGERATOR TEST STATION A 20/1 z 2 4 ', 1;x 20/1 A • EFRIGERATOR TEST STATION 1200 28 30/2 •<J 29 1200 •E RIGERATOR TEST STATION A 20/1 STACKABLE DRYER RECEPT 2184 2.4 20/1 A • EFRIGERATOR TEST STATION 1200 30 A 31 1200 • EFRIGERATOR TEST STATION A 20/1 2.4 ,1 x: t 20/1 A • EFRIGERATOR TEST STATION 1200 32 SPACE 0 33 1200 • EFRIGERATOR TEST STATION A 20/1 r 4.2 r ,. a �, 60/2 A PRS REPAIR 3000 34 1440 SPACE P 38 SPACE S 20/1 .x. +>f , A 3.0 SPACE A 28 3000 38 29 1440 37 SPACE S 3 =,. a I 1.2 /'• {' a ^ =: 20/1 A PRS REPAIR 1200 38 A 31 39 SPACE S 0.0 1 2 4n ? 20/1 A PRS REPAIR 1200 40 S 41 SPACE 8 Iza .,z,,. 0.0 S S SPACE x 42 S _.__.___ ,.._._..}___.__4_.L..._, i---� 1 SUB TTL -. ,- .. -___. _...._., 15.6 _1 17.4115.0 _.__._ _ -...__ _ _._ C __.._- � __.t-1 ._ _ S SPACE S 0.0 _! SPACE S S SPACE y,c +' 38 S 39 SPACE S :s I 0.0 7 ":, S SPACE =M 40 N 17,3 D EMAND FACTORS PER NEC. S BRKR NOTES: *) _'+ * 0.0 0 SPACE ' , 0 0 L T N 0:00 .; et 000 sat:, ' ' 10K REC.'S � ' 1 .0 , VA REC 1. A.,-, 5 G S T% O TO T LO 0 APPLIANCES. # F , LOAD ,,,.. „ D TTL LF, F TRACK - I7 A �,, UNITS , ;. 1 ..:., .220,4. 220.44 430.24 430.25•'' : ;: 20,43(B) , 2 2 , 1 = BR 2 = GFCI EAKE R L O CK 13.0 11.6 14.5 BREAKER _ 3 =SHUNT TRIP 4 =TIME CONTROL ___ 5 = HANDLE TIE BRKR NOTES: 11 Ella L'M 111 aliallal 0 0 0 LTNG 0 0 Let BAL. K27 ()KVA REC.'S 'LARGEST 0 M OT APL. TRACK 1 0' R EC O i 0 ;0 6 , � OR . 1NA MOTOR ' 0 LOAD :;= '' OR C`S= " 34 NI ,:: OAPPLIAN E UNITS # F, LOAD TTL LF OF TRACK : LF LOAD ''11. 1111111111111111111111111 111111111111111110111 , , 31 '' .2' , LAPL. 20.58 "L -,. DEMAND RACTORS, ''- ` . ;. .19''UN1TS .. ^' a - • PER NEC: 2 220.42 42 0 4'0'14 430.25 �� 0 22 = .56. .. > . 220.43(B) , .: :'�: _ BRKR NOTES: i1 = BREAKER LOCK 2 = G FC I BREAK 3 = SH U NT TRIP I ER a 1:' . DD RACK , -;!; , -: -, .,.,,. ;? .' '. 0 .00 L T NCi '1aALt0RKE @1 0 V flS EG : } " LARGEST MOTOR ;. MOTOR LOAD r F^ APPLIANCES =I' `'P '' L. D LOAD A TTL LF OF TRACK TRACK LOAD . - , `... 0 , ;TT L r .0 €00 1111111111111 PANEL SCHEDULE ( I ! 1 1 1 1 t 1 1 I I i 1 1 1 ■ 4 i 1 I 1 I BRANCHES: NAME PLATE __I_ 1 -- 'r_.�.___.._ NAE PLATE -7-1-1M7- : _...____..__I __ "H" - _I_____1----1-- 72.00 23.04 64.05 PANEL L LOAD T- T-1-1---'m VA - CONNECTED ......_.__ . A - DEMAND L DEMAND AMPS ' . .1 _ LOAD LOAD __ i. I 1 1 I r_T____I__. 120/208 VOLT 225 AMP. MP MAIN LUG 4 -WIRE 42 CKT LOCATION: WASHER TEST AREA BUSS _._.�_.___.___ 200 3- PHASE, 225 __._.._.__._____._____._. AMP. MAIN LUG 4 -WIRE 142 CKT d CIRCUIT BREAKER, _..._., I_..- ._.___.... ENTRANCE: FED FROM: ,__L__ . TOP PANEL 'MOP' FEEDER A L R MS ___. PANEL LOAD TRACK LIGHTING SERVES MOTOR" SERVES HEATING SPARE SPACE - , i BRANCHES: BRKR TYPE: BOLT -ON AMPS/ POLE SIZE: S I 1 50 AMP �, 2/0 THHN CU 39.07 25.40 KVA - CONNECTED LOAD KVA - DEMAND LOAD MOUNTING: SURFACE ` ": SETS: 1 WIRE: A.I.C: 22K 2 COND. 2' ELECT. RAN G 70.60 A0 TTL DEMAND AMPS ._.a �. I� 8 0 x -.._.. ____ __ -_-. RECPT ___ -_ _ _.__ I A ---- __._._ _ __. __. _ �_____..___ 3000 ELECT. RANGE RECPT __...__. 0/2 IN 7 ! . _ SERVES APPLIANCE: A ELECT. RANGE RECPT _ M SERVES MOTOR , 3000 SERVES MISCELLANEOUS: 8 0 ? •ii LOAD A A SERVES RECEPTACLES: R GAS RANGE 10V RECEPT A RAN 1 P H SERVES HEATING T 1 1 1 1 0 0 20/ / s GAS RANGE 110Y RECEPT 1440 SERVES MISCELLANEOUS: MS AMPS/ LOAD (KVA) AMPS/ S SPARE / SPACE 0 1 0. 0 .. -. ., .r NT CKT# VA 1 i 1 3 POLE A B C POLE ELECT. RANGE RECPT LEC I I 1 I 1 I VA CKT# NT A 1 1440 WASHER A 20/1 2.9 �;?: � ' 20/1 A WASHER 1440 2 0/2 6.0 A 3 1440 WASHER A 20/1 • , 2 9= WASHER 20/1 A WASHER 1440 4 2011 A 5 1440 WASHER A 20/1 ,: 1 a 2.9 20/1 A WASHER 1440 6 20/1 A 7 1440 WASHER A 20/1 25 :'t y 20/1 A WASHER 1440 8 20/1 A 9 1440 WASHER A 20/1 az 28 :s =.. 20/1 A WASHER 1440 10 20/1 8.0 11 1440 WASHER A 20/1 ?i , 'sk 2.9 20/1 A WASHER 1440 12 50 " / A ELECT, RANGE RECPT A 13 1440 WASHER A 20/1 2.9 t f'�u'` ? •. 20/1 A WASHER 1440 14 20/1 A 15 1440 WASHER A 20/1 d� 1 4 if'$ wJ►' ia,_..3.. -_ t S SPACE '- 16 39 `�.�y�� 17 2184 STACKABLE DRYER RECEPT A 30/2 1. c 4.4 30/2 A STACKABLE DRYER RECEPT 2184 18 Alik SPACE 3 19 2184 0.0 A 9 SPACE 4 4 t s. A A S 2184 20 20/1 I 8,0 21 2184 STACKABLE DRYER RECEPT A 30/2 •<J 4.4 - ;•$ Ye. 30/2 A STACKABLE DRYER RECEPT 2184 22 20 1 A 23 2184 LOCK TRIP TIE A 4 F> 4.4 � : , A 0.00 LTN 000 ` "1et 6.00 - BAL 0 - L TT 23.04 L 2184 24 1; 3 .24-4 p7 ' A 29 1 SPACE 0 i 1 0.0 e #3 s' 1 A S SPACE 26 20/1 A 27 1440 SPACE P S 1 -"1 a; k 0 0 .x. +>f , A S SPACE r 1 28 20/1 A 29 1440 SPACE S 3 =,. a I tfi G 0.0 A S SPACE 2 9 30 20/1 A 31 1440 SPACE S 0.0 q'r i� a S S SPACE , 32 S 33 SPACE S "`' 00 'I d S S SPACE x 34 S 35 SPACE S '' tY a 0.0 S S SPACE 0 0 36 S 37 SPACE S 0.0 _! SPACE S S SPACE y,c +' 38 S 39 SPACE S :s I 0.0 7 ":, S SPACE SUB TTL 40 17.3 17,3 41 SPACE S 1 *) _'+ * 0.0 0 SPACE 42 i1 SUB TTL 13.0 11.6 14.5 I DEMAND FACTORS.. '. PER NEC: BRKR NOTES: 11 i 1 111 0 0 0 LTNG 0 0 Let BAL. K27 ()KVA REC.'S 'LARGEST 0 M OT APL. TRACK 1 0' R EC O i 0 ;0 6 , � OR . 1NA MOTOR ' 0 LOAD :;= '' OR C`S= " 34 NI ,:: OAPPLIAN E UNITS # F, LOAD TTL LF OF TRACK : LF LOAD ''11. `r`': 11 ' "+ 220.42 22044 430,24 „,,. 440,25;:::, " 220.56 20 42 9,24 DEMAND RACTORS, ''- ` . ;. .19''UN1TS .. ^' a - • PER NEC: 2 220.42 42 0 4'0'14 430.25 �� 0 22 = .56. .. > . 220.43(B) , .: :'�: _ BRKR NOTES: i1 = BREAKER LOCK 2 = G FC I BREAK 3 = SH U NT TRIP I ER 0 000 , -;!; , -: -, .,.,,. ;? 12 = GFCI BREAKER ,3 =SHUNT TRIP 0 .00 L T NCi '1aALt0RKE @1 0 V flS EG : } " LARGEST MOTOR ;. MOTOR LOAD r F^ APPLIANCES =I' `'P '' L. D LOAD A TTL LF OF TRACK TRACK LOAD . - `... 0 , ;TT L I .4 = TIME CONTROL .0 €00 5 = HANDLE TIE , TI 14 = TIME CONTROL �I�a 15 = HANDLE TIE MUNN 251 4 TLLA MI Iliii D. ADD. 1 1 I EXTERIOR SPACE 18340 EXISTING METER BASE 120/208V RELOCATED PANEL "A" EXISTING FEEDER J TO EXISTING UTILITY TRANSFORMER SINGLE LINE DIAGRAM SPACE 18340 SCALE: NOT TO SCALE PANEL SCHEDULE - - - - -I NAME PLATE : I H D BRANCHES: 1 _... NAE PLATE -7-1-1M7- : -1- . 120/208 'VOLT 1 BUSS 225 { 200 AMP i MAIN LUG 3 ASE 4-WIRE 42 CKT. PH i BRANCHES CIRCUIT BREAKERE, BRKR TYPE: :BOLT -ON N._.... 1..... MOUNTING: 'SURFACE I A.I.C: :22K t LOCATION: ' RANGE TEST AREA € 1 I L.. ENTRANCE: I T OP FED FROM: PANEL 72.00 23.04 64.05 PANEL L LOAD T- T-1-1---'m VA - CONNECTED ......_.__ . A - DEMAND L DEMAND AMPS ' . .1 _ LOAD LOAD __ _...._.. _ „ SIZE: SETS: FEEDER 20 200 AMP _...... _._ .... ........... ......._... 1 WIRE 4/0 THHN CU COND.. 2' TEST AREA BUSS 200 3- PHASE, 225 AMP. MP MAIN LUG 4 -WIRE 42 CKT ( ( ENTRANCE: FED FROM: NT :CKT# NT CKT# P SERVES APPLIANCE: V RVE S LIG SE TING :. H C 3 SERVES RECEPTACLES: ,SERVES MISCELLANEOUS A L R MS T M H S TRACK LIGHTING SERVES MOTOR" SERVES HEATING SPARE SPACE - , FEEDER 150 AMP 1 WIRE: CKT# NT AMPS/ LOAD POLE A (KVA). B I C AMPS/ POLE MOUNTING: 1 A.I.C: GAS RANGE 110V RECEPT S 20/1 0.0 , ` ": 20/ S GAS RANGE 170V RECEPT TTL DEMAND AMPS 2 2 3000 ELECT. RAN G RECPT ERE T A0 2 8 0 x 50 ' E A ELECT. RANGE RECPT A 3000 3000 RECPT 3000 i I A ,. 8 0 A L I`3000 \ 3000 ELECT. RANGE RECPT A A 0/2 IN 7 ! . _ 50/ A ELECT. RANGE RECPT 3000 3000 H SERVES HEATING A A , 3000 SERVES MISCELLANEOUS: 8 0 ? •ii LOAD A A C AMPS/ POLE GAS RANGE 10V RECEPT A RAN 1 P S '0 1 / ,r T 1 1 1 1 0 0 20/ / s GAS RANGE 110Y RECEPT 1440 WASHER A 20/1 I ';:. GAS RANGE 110V RECEPT 0 0 1 0. 0 .. -. ., .r _..,. _ 20/1 1 S GAS RANGE 1 0 RECEPT N 1 V GAS RANGE 110V RECEPT S 3 1440 WASHER A 9000 3000 ELECT. RANGE RECPT LEC A A 0/2 8 0 A 80/ . A ELECT.. RANGE RECPT A 3000 3000 • <..,_. 1440 � ' A 20/1 3000 ELECT. RANGE RECPT A A 0/2 6.0 A WASHER 50/ i A ELECT. RANGE A RECPT 3000 • , 1440 WASHER A 3000 2.9 8 0 ,c' 2011 A 3000 1440 8 r 2 9 GAS RANGE 110V RECEPT S 0/1 r,0 0 20/ i 9 GAS RANGE 110V RECEPT 20/1 A WASHER 1440 p O S R NGE 110V RECEPT A A 8 0 1 0 0 WASHER A 20 1\ / S GAS RANGE 110V RECEPT S 2,9 20/1 A WASHER 3000 3000 ELECT. RANGE RECPT A A 0/2 .•. ^" 8.0 .,.. *'. 50/ A ELECT. RANGE RECPT 3000 2. ELECT RANGE RECPT r •.Ft', 20/1 8.0 WASHER A 3000 15 ��: 300 0 3000 ELECT. RANGE RECPT E E T. A 0 2 6.0 / 8 0 :;r z -,� 50 " / A ELECT, RANGE RECPT A 3000 3000 Di 16 A la 17 GAS RANGE 110V RECEPT • 0/1 =` 0.0 20 11 S GAS RANGE 110V RECEPT 20/1 A ® 1440 SPACE S FAI1 0,0 . ''.: , x I DISH WASHER wJ►' ia,_..3.. -_ t 138 2.9 '- 0.0 39 `�.�y�� *I�� w �- •a- � ��_ 1440 20 0.0 ., a „'i_ 21 S ,E' SPACE DISH WASHER 40 20/1 41 ' , %,' Alik SPACE 3 •'' 1440 0.0 39 9 SPACE 23 42 DISH WASHER A 20/1 S Q SPACE SUB TTL 20/1 I 8,0 36,0 18.7 24 I _- 1440 DISH WASHER A 0 2 1 2 2.9 i y v 20 1 A DI H WA HER DISH WASHER 1 ' BRKR NOTES: 1 = BREAKER 2 GFCI BREAKER 3 HUNT 5 4 TIME CONTROL HANDLE _ LOCK TRIP TIE ._.._.. 27 1 7 1 1 1 • DISH WASHER � : , DEMA N O FACTORS � PER NEC 0.00 LTN 000 ` "1et 6.00 - BAL 0 - L TT 23.04 L .0 OKVAREC 70 :! C41 'R S EC. 5 'CMG EST MOTOR MOTOR, LOAD '. OF APPLIANCES . APL LOAD TTL LF TRACK OF TRAC TRACK' LOAD " ;I s 220.42 4 KVA 430.25 NI T S '< 220,55 , u : 220.43(B) I 1; 3 .24-4 p7 ' A 1 1 1 = = "ADD. 1 i 1 29 ; 1 A 1 PANEL SCHEDULE - - - - -I JANUARY 6, 2012 - ___r_.i<_ -M-- -__ __ ,..___r.,_.1__I_.,.._I___I..__. BRANCHES: 1 _... NAE PLATE -7-1-1M7- : -1- . "J" _...I _._._T___- ._..)_._..__r_ -- 1 _Ir 120/208 VOLT SIZE: SET S LOCATION: WASHER MT TOP PANEL'MDP' TEST AREA BUSS 200 3- PHASE, 225 AMP. MP MAIN LUG 4 -WIRE 42 CKT ( ( ENTRANCE: FED FROM: NT :CKT# PANEL LOAD A L R MS BRANCHES: I CU IT BREAKEN BOLT -ON T M H S SIZE: SETS: FEEDER 150 AMP 1 WIRE: i 1 1 2/0 THHN CU 48,96 31.82 I 1 KVA - CONNECTED LOAD KVA - DEMAND LOAD BRKR TYPE: MOUNTING: SURFACE A.I.C: 22K 20/1 0.0 COND. 2' 1 20/ 88.47 TTL DEMAND AMPS 2 3000 ELECT. E RE PT A RANGE RECPT A 0 2 / ''; 6.0 'I=" •I:! 50 ' A A ELECT. RANGE RECPT 3000 i I 3000 ,. SERVES APPLIANCE: SERVES LIGHTING: ER A L 3000 T M TRACK LIGHTING SERVES MOTOR 7 ! 3000 ELECT. SERVES RECEPTACLES: R 8.0 • H SERVES HEATING A A ELECT. RANGE RECPT - NT CKT# V A SERVES MISCELLANEOUS: MS AMPS/ POLE LOAD A (KVAL B C AMPS/ POLE 0 SPARE 1 SPACE 1 1 1 I VA CKT# NT T 1 1 1 1 1 1440 WASHER A 20/1 2.9 ';:. , ' 20/1 A WASHER 1440 2 13A GAS RANGE 110V RECEPT S 3 1440 WASHER A 20/1 S 2 9 ' .,: 20/1 A WASHER 1440 4 0 0/2 l 5 1440 WASHER A 20/1 RECPT 3000 2 9 20/1 A WASHER 1440 8 3000 7 1440 WASHER A 20/1 2.9 `. . " 2011 A WASHER 1440 8 r 2 9 1440 WASHER A 20/1 - 2 9 s „ <. 20/1 A WASHER 1440 10 2 11 1440 WASHER A 20/1 20/1 S 2,9 20/1 A WASHER 1440 12 3000 ELECT. RANGE RECPT A A 13 1440 WASHER A 20/1 2. ELECT RANGE RECPT - 20/1 A WASHER 1440 14 15 1440 DISH WASHER A 20/1 •. 2 9 j 20/1 A DISH WASHER 1440 16 A ELECT. RANGE RECPT 17 1440 DISH WASHER A 20/1 3000 A 2 9 20/1 A DISH WASHER 1440 18 3000 •4 19 1440 DISH WASHER A 20/1 2.9 '- 0.0 20/1 A DISH WASHER 1440 20 21 1440 DISH WASHER A 20/1 2 9 ' , %,' 20/1 A DISH WASHER 1440 22 39 �v� ' w •- 23 1440 DISH WASHER A 20/1 S Q SPACE 2.9 20/1 A DISH WASHER 1440 24 ' 25 1440 DISH WASHER A 0 2 1 2 2.9 42 v 20 1 A DI H WA HER DISH WASHER 1440 26 36.0-15. 27 1440 • DISH WASHER A 20/1 2 9 4L;! 20/1 A DISH WASHER 1440 28 i 1 29 1440 DISH WASHER A 20/1 2.9 20/1 A DISH WASHER 1440 30 t 1 1 f I 1 -"1 31 1440 DISH WASHER A 20/1 2. r 1 ^ "' 20/1 A DISH WASHER 1440 32 33 1440 DISH WASHER A 20/1 2 9 20/1 A DISH WASHER 1440 34 35 SPACE S , 00 S SPACE 36 37 SPACE S 0.0 x e = S SPACE 38 39 SPACE S 0 0 +; S SPACE 40 41 SPACE S y,c +' 0.0 S SPADE 42 SUB TTL 17.3 17,3 14,4 1 1 i1 11 DEMAND FACTORS.. '. PER NEC: BRKR NOTES: 0 0 0 LTNG 0 0 Let BAL. K27 ()KVA REC.'S 'LARGEST 0 M OT APL. TRACK 1 0' R EC O i 0 ;0 6 , � OR . 1NA MOTOR ' 0 LOAD :;= '' OR C`S= " 34 NI ,:: OAPPLIAN E UNITS # F, LOAD TTL LF OF TRACK : LF LOAD ''11. `r`': 11 ' "+ 220.42 22044 430,24 „,,. 440,25;:::, " 220.56 20 42 9,24 1 1 BREAKER LOCK _ 0 000 , -;!; , -: -, .,.,,. ;? 12 = GFCI BREAKER ,3 =SHUNT TRIP `... 0 , ;TT L I .4 = TIME CONTROL 5 = HANDLE TIE , TI 31,82 .TTL ADD. 1ri1 r I1 11 EXTERIOR SPACE 18350 PANEL "MDP" INCOMING METER SECTION PANEL SCHEDULE NAME PLATE JANUARY 6, 2012 Y : I Y E i.. MAY 1 2012 BRANCHES: 120/208 ;VOLT BUSS 225 200 AMP MAIN LUG 142 CKT WIRE KT t BREAKER c -ON CE m# r LOCATION: RANGE TEST AREA I ENTRANCE TOP FED FROM: PANEL MDP PANEL LOAD 3-PHASE, BRKR MOUNTING 1 4 1 C CIRCUIT TYPE: (BOLT f SU t RFA _A.I.C: 22K SIZE: SET S FEEDER 200 AMP 1 1 4 THHN CU 1 WIRE: 0 T N 1 COND.! 2' 72.00 ! A - CONNECTED LOAD 23.04 A DEMAND LOAD 64 OS L DEMAND AMPS 77 NT :CKT# SERVES APPLIANCE: SERVES LIGHTING SERVES RECEPTACLES: SERVES MI SCE AN L EOUS L , - A L R MS T M H S TRACK LIGHTING SERVES MOTOR SERVES HEATING SPARE SPACE •KT# NT AMPS/ POLE LOAD A KVA B C AMPS POLE 1 GAS RANGE 110V RECEPT S 20/1 0.0 I ,,r -," 20/ S GAS RANGE 110V RECEPT 2 3000 ELECT. E RE PT A RANGE RECPT A 0 2 / ''; 6.0 'I=" •I:! 50 ' A A ELECT. RANGE RECPT 3000 5 3000 ,. 6.0 3000 7 ! 3000 ELECT. RANGE RECPT A RA E R T A 0 2 / 8.0 • 50/ / i A A ELECT. RANGE RECPT 3000 [r+ ■ 9 3 000 8 0 3000 0 1 ! GAS RANGE 110V RECEPT S 0 1 / .. 0.0 20 / j S GAS RANGE 110V RECEPT 13A GAS RANGE 110V RECEPT S 0/1 0.0 r, 20/1 S GAS RANGE 110V RECEPT 4 1' 1 17/ 3000 ELECT. RANGE RECPT A L 3000 A 0 0/2 l 8 0 „ „ 50 J A A ELECT. RANGE RECPT 3000 ,,��•� 8.0 3000 8 1: 1 21 3000 ELECT. RANGE RECPT A 3000 A 0/2 8,0 8 0 °; 'sw; 50/ A A ELECT. RANGE RECPT 3000 3000 r 2 2' GAS RANGE 110V RECEPT S 0/1 - 0.0 20 /' S GAS RANGE 110V RECEPT 2 GAS RANGE 110V RECEPT 5 0/1 0.0 . 20/1 S GAS RANGE 110V RECEPT 6 2 3000 ELECT. RANGE RECPT A A 0/2 2 8.0 ? 6 0 A A ELECT RANGE RECPT 3000 2: 3000 5.0 3000 •0 311 3000 ELECT. RANGE RECPT A 0/2 6.0 • 50/ . A ELECT. RANGE RECPT 3000 3. 3000 A 80 - A 3000 •4 3 0 GAS RANGE 110V RECEPT S 0 1 '- 0.0 20 1 S 10 GAS RAN E C P G 1 V RE E T 36 37 SPACE S 0.0 .:",41116„...416,....416.-Al -1•- 38 39 �v� ' w •- 7.0" S Q SPACE 40 41 SPACE S ' S SPACE 42 i SUB TTL 18.0 36.0-15. 1 i i i 1 LOCK _ TRIP TR TIE I _.... = -- DEMAN D FACTORS PER NEC:' BRKR NOTES: -" t 1 1 f I 1 -"1 8 QO 000 0:00 0 23.04 LING 0 220'42 L 1 1st t V A R C. �1 20, 44, BAL. REC.'S CO 5 437 LARGEST M oTOR KVA 430.2 T MOTOR A , TLM TORL D O F APPLIANCES NITS 220.55 L APL LOA - a TT OF LF .; LF TRACK 4 220,43(8) ADD. TRACK LOAD 1 BREAKER 2 GFCI BREAKER 3 = SHUNT 4 TIME CONOL 5 HANDLE = SHEET NOTES 1. DIAGRAM SHOWN IS SCHEMATIC. REFER TO THE POWER PLAN FOR LOCATIONS OF EQUIPMENT. 2. THE INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF THE POWER COMPANY AND SEARS REPRESENTATIVE. 3. REFER TO THE MECHANICAL PLAN FOR THE LOCATION OF THE HVAC EQUIPMENT. 4. REMOVE EX I ST ING SPARE CIR C UIT BREAKERS WHERE NECESSARY TO MAKE ROOM FOR NEW CIRCUIT BREAKERS. REWORK EXISTING SWITCHBOARD AS REQUIRED. PROVIDE ALL REQUIRED MOUNTING HARDWARE. 5. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, , PULL WIRES, CABLES, PULLBOXES, CONCRETE ENCASEMENT OF CONDO S TRANSFORMER T TRAN I RP AD BARRIERS, POLE RISERS, TRENCHING AND BACKFILL AND PAY ALL UTILITY CO. FEES AND REMENTS U NCLUDE ALL REQUIREMENTS QI IN SCOPE OF WORK. 6. CONTRACTOR SHALL COORDINATE WITH THE UTILITY COMPANY FOR FINAL AND EXACT WORK MATERIAL REQUIREMENTS AND CONSTRUCT TO UTILITY COMPANY ENGINEERING PLANS AND SPECIFICATIONS. 7. ALL TERM I NATORS AND ENCLOSURES SHALL BE RATED FOR USE WITH 90 DEGREE CELSIUS CONDUCTORS. 8. CALL UNDERGROUND ALERT BEFORE YOU DIG. 9. EC SHALL COORDINATE THE UPGRADE OF EXISTING BUILD I NG UTILITY TRANSFORMER, RECONNECT EXISTING ELECTRICAL SERVICES THAT ARE TO REMA I N IN SERVICE, AND PROVIDE NEW FEEDER AND EQUIPMENT TO SPACE 18350 AS SHOWN IN THIS ELECTRICAL SET OF CONSTRUCTION DRAWINGS. 10. EC SHALL BALANCE PANEL LOADS UPON INSTALLATION OF CIRCUITING. 11. EITHER THE 110V OR 208V RECEPTACLE WILL BE USED AT EACH RANGE OR DRYER TEST STATION, PANELS D,E,F,G ONLY REFLECT 220V LOADS TO REFLECT WORST CASE SCENARIO. DIVERSITY HAS BEEN APPLIED PER NEC 220.55 FOR ELECTRIC RANGES AND 220.56 FOR ALL OTHER APPLIANCE LOADS. r 4 #4/0,2 "C �Q rc-71 L -J LiJ (3) SETS OF 4- 500KCMIL,3 "C. TO UTILITY TRANSFORMER EXISTING EXISTING PANEL "B" SUB PANEL 0 a PANEL "C" PANEL "D" PANEL "E" N PANEL "F" PANEL "G" PANEL "H" PANEL "J" DISCONNECT AND REMOVE EXISTING METER AND 200A DISCONNECT AND PROVIDE NEW 200A FEEDER TO EXISTING PANEL "A &B" SINGLE LINE DIAGRAM SPACE 18350 SCALE: NOT TO SCALE ELio b 3.9 REVIEWED .I-UN COMPLIANCE WITH NFPA 70 - NEC SEP 2 8 2012 City of Tukwila BUILDING DIVISION RECt9VED CITY OF TUK1'_ A SEP 13 2012 PERMIT CENTER ISSUE DATE ISSUED FOR SCOPE OF WORK JANUARY 6, 2012 ISSUED FOR BID MAY 1 2012 REVISED ELECTRICAL SERVICE A MAY 2 , 2012 ISSUED FOR REVISIONS 8 PERMIT A JUNE 27, 2012 A SEPTEMBER 10, 2012 ISSUED FOR PERMIT COMMENTS SEARS HOLDINGS co O a 0 t-4 CX (As rts N W M M z J W -J 00 (i) 06 LI -J 0 LTC! V z 0 z 0 CYO Tz • VJ W < J � 1--- O LO O >,_ CO co CEO C37 r Project ArchJ Engineer M.PELINI Drawn: J. FALLOS Checked: J. LINEGAR Date: OCTOBER 28, 2011 Sheet No: E -4