Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL12-0705 - WESTFIELD SOUTHCENTER MALL - AEROSOLES
AERO S OLES 690 SOUThCENTER MAIL EL1 2-0705 City of/Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 9202470010 Address: 690 SOUTHCENTER MALL TUKW Project Name: AEROSOLES ELECTRICAL PERMIT Permit Number: EL12 -0705 Issue Date: 09/24/2012 Permit Expires On: 03/23/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: MARGO KOZICH Address: 2136 PURCELL DR , FERNANDINA FL, 32034 Contractor: Name: HOME RUN ELECTRIC LLC Address: PO BOX 217 , BOTHELL WA 98041 Contractor License No: HOMERRE974K2 Phone: 904 491 -6314 Phone: 425 489 -0791 Expiration Date: 05/22/2013 DESCRIPTION OF WORK: NEW LIGHTING FIXTURES, LIGHTING CONTROL /SWITCHING, AND RECEPTACLES. Value of Electrical: NRES: $15,000.00 RES: $0.00 Type of Fire Protection: SPRINKLERS /AFA Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Dibt, Fees Collected: National Electrical Code Edition: $438.13 2008 Date: 461 -2J- -r2_ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o g'- pe -. rmance of yvork. I authorized to sign and obtain this electrical permit. Print Name: m Date: 6 2 T -1 Z This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL1 2-0705 Printed: 09 -24 -2012 • PERMIT CONDITIONS • Permit No. EL12 -0705 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -0705 Printed: 09 -24 -2012 Site Address: CITY OF TUKWILJ Community Developm )epartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Tenant Name: ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: "1 r Y.2- i cot O �,-�� W� fr Suite Number: 27 Floor: / `,o 5 New Tenant: ❑ Yes Z,.. No Name: l.JVG`%'Tic /eC.d LL.L Address:// NI 407/i),46 mLt/,J, City: // /✓t1L -zz State: gij Zip.7Lv Z Phone: ;04^ It' %, -k3./4 Fax: y0¢ -- ,K GfO-U?77 Name 7/, vo �,/o /� Address :p,,.4;,, f- �a/x.GL 4,/d4- City: ft w e///ni State: , 1 Zip: z0 Phone: ;04^ It' %, -k3./4 Fax: y0¢ -- ,K GfO-U?77 Email: Company Name: Address: City: '"Mate: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ ! %Ot:V '�- Scope of Work (please provide detailed information): /1/614/ ziam-/A/67 /X' J, j, (i//T /4/4 .4V%eOL / re:-/1/4/Li.- ,4v Will service be altered? ❑ Yes .0-No Adding more than 50 amps? ❑ Yes „ErNo Type of Use: Tvpe of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light H: \Applications\Forms- Applications On Line \2011 Applications\Electrical Permit Application Revised 8 -9 -11. docx Revised: August 2011 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $152.85 $81.90 ea $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added /altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured /mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: /y%"T�U�/��' i( Mailing Address: /& 3� 7/4 /300 A //?TL( 5T Day Telephone: H: \Applications\Forms- Applications On Line \2011 Applications\Electrical Permit Application Revised 8 -9 -11. docx Revised: August 2011 bh Date: 7 / 2 oz4/1/6 £ 7z/' City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL12 -0705 Address: 690 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 07/30/2012 Applicant: AEROSOLES Issue Date: Receipt No.: R12 -02689 Payment Amount: $87.63 Initials: WER Payment Date: 09/24/2012 02:22 PM User ID: 1655 Balance: $0.00 Payee: JOHN SMITH TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 04323G ACCOUNT ITEM LIST: Description 87.63 Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 87.63 Total: $87.63 doc: Receiot -06 Printed: 09 -24 -2012 Ci f of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: /hvww. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -02230 Initials: JEM Payment Date: 07/30/2012 User ID: 1165 Total Payment: 1,368.77 Payee: COMMERCIAL PERMIT GROUP, INC. SET ID: S000001779 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member D12 -251 EL12 -0705 M12 -115 TOTAL: Amount 957.06 350.50 61.21 957.06 TRANSACTION LIST: Type Method Description Amount Payment Check 3283 1,368.77 TOTAL: 1,368.77 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 PLAN CHECK - NONRES 000.345.830 TOTAL: 350.50 1,018.27 1,368.77 'INSPECTION RECORD Retain a copywith permit INSPECTION NO. PERMIT NO. all-0705" -CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter ;Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project :. Type of Inspection: Address:.: ` -tr Date Called: Special Instructions: Date Wanted:. 10 , j /( J a r Requester: Phone No Approved per applicable codes. D Corrections required prior to approval. COMMENTS; Put, . 14QK ii/oAs f r Inspector: . Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO." PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit.Inspection Request Line (206) 431 -2451 Wzo1oS Project: 0 44-S Type of Inspection: -^7 ,w Address: " ii/ �{J/ Date Called: — .food oP t1eJ t(c Jt2* 6/ L&4I/ D %d{�riio1.��. i•I�t�# fin11 ,rte -D ?4m ' 5 , e Special-Instru2tions :: ) i &CAM'-. 6.15 -e 4FC..t 5e -Act t2.4``1c.CP Date Wanted :. 4� 1alt<v r.m,. Thm. Requester: :t-r - B&t9% (& ')t I _ Phone No Approved per applicable codes. Corrections required prior to approval. COMMENTS: - . `5v :Aq `` ec•4wt t5 tJ — .food oP t1eJ t(c Jt2* 6/ L&4I/ D %d{�riio1.��. i•I�t�# fin11 ,rte -D ?4m ' 5 , e IN l c+ 51l . > UNIT. > 6- (Kri) 4 I) Ad) ) i &CAM'-. 6.15 -e 4FC..t 5e -Act t2.4``1c.CP t'ttt 2. S..'-f.--7- t i f`-1 tnl`t P c &GJt ri its f f 0.4JP0 IA) t f'f trJ Pn►pdet... A4 L€-oJti.z kucorece. ,trot: SA,W6LJ -nab :t-r - B&t9% (& ')t I _ Date: /0// o 12.-- 1 REINSPECTION FEE REQUIR E D. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. - INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. `CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 >I? (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 aiLo1K Project: /I Type of Inspection: Address: ((' Date Called: Special Instructions:. Date Wanted:. 0 to I a.m p.m. Requester: i Phone No: Approved perapplicable codes. Corrections required prior to approval. COMMENTS: Inspector: - j (P9(� Date: /0 /01 fa■-- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. f� INSPECTION RECORD 1 Retain a copy with permit t' Z 07 INS CTION NO. py p PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 46 i f5 Type of Inspection: 7003 Address: � QO rA ti Date Called: Special Instructions: ' Date Wanted:. �1 V 0 a.m . p.m. Requester: T Phone No: � ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: f� I T � A id-' 6Afck A-cass S'• Del tCtAle / ptryD tJ • Inspector: ° ajtcic Date: 1045.112...._ n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ett1,07o5i INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 4CAO CO Type of Inspection: 7e,5 Address: '7o , !r /`` Date Called: Special Instructions: Date Wanted:. a.m. p.m. Requester: !r - Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: wq l .57ar P-P sorb"/ r Inspector: 61/4-A Date: 10/04 /r n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD 1,1 ;alb Retain a copy with permit In PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 tZ- (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: /t' Va' 501..0 Type of Inspection: 7O D I Address: (010 rii-vt/ Date Called: Special Instructibns: t Date Wanted:. 0 / v� a:m: Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: c. tokeci o4 r ,� S A eADVi1) A Inspector: 4- 1 F-7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: /6 o2-0 INSPECTION NO. INSPECTION RECORD Retain a copy with permit ux 405 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451. Project: At It.a SO Type of Inspection: VV/ Address: 1j� ' Date Called: Special Instructions: Date Wanted:. l a rr m. Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: AflxeS Akr A 61 Rkcfp rcA, NicterE- Inspector: —71 trt Date: /0 /7! 1 /1 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ERMIT COORD COPP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0705 DATE: 07/30/12 PROJECT NAME: AEROSOLES SITE ADDRESS: 690 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: $L�ifdinislon C3i-t4 Public Works Fire Prevention I I Planning Division ❑ Structural n Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 07/31/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required n DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/28/12 Approved n Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople P.er Friendly Page Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company HOME RUN ELECTRIC LLC 4254890791 Po Box 217 Bothell WA 98041 King Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602291057 Active HOMERRE974K2 Electrical Contractor 5/22/2003 5/22/2013 General Unused Master Electrician INFORMATION License SMITHMT951 DQ Name SMITH, MICHAEL T Status Active Business Owner Information Name Role Effective Date Expiration Date SMITH, MICHAEL Partner /Member 05/22/2003 Bond Amount SMITH, JESSICA Partner /Member 05/22/2003 9807205 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Lexon Ins Co 9807205 05/22/2011 Until Cancelled $4,000.0005/06/2011 1 COLONIAL AM CAS & SURETY OF MARYLAND LPM4063917 05/22/2003 Until Cancelled 05/22/2011 $4,000.0005/22/2003 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EJACH00638 6/7/2010 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 09/24/2012 LIGHTING CODED NOTES PROVIDE NEW 11MECLOCK AND CONTACTORS. REFER TO SCHEDULES ON THIS SHEET AND SPECIFICATIONS FOR MORE INFORMATION. 2. CONNECT CIRCUIT THROUGH NEW CONTACTOR 'LC2' WHICH IS CONTROLLED BY NEW 24 HOUR /7 DAY 11MECLOCK TC. COORDINATE ON /OFF SCHEDUUNG WITH OWNER AND LANDLORD. 3. EXISTING JUNCTION BOX, DISCONNECT SWITCH, AND CIRCUIT FOR SIGNAGE CONNECTIONS SHALL REMAIN. E.C. SHALL PROVIDE ALL SIGNAGE WIRING TO THIS BOX. (SIGNAGE BY OTHERS) 4. NEW MASTER LIGHTING SWITCH BANK AT 42" AFF. SEE DETAIL ON THIS SHEET FOR SPECIFIC SWITCHING INFORMATION. PROVIDE LABELS ON SWITCHES AS INDICATED ON DETAIL. 5. PROVIDE 2-HOUR OVERRIDE TIME SWITCH EQUAL TO INTERMA11C FF SERIES. OVERRIDE SWITCH SHALL SERVE AS THE EXTERNAL OVERRIDE SIGNAL TO 11MECLOCK 'TC' POLE #1. PROVIDE PRINTED LABEL AT SWITCH LOCATION TO READ "OVERRIDE SWITCH ". REFER TO UGHiiNG CONTACTOR SCHEDULES, UGHTING CONTROL DETAIL, AND SWITCH BANK DETAIL ON THIS SHEET FOR ADDITIONAL INFORMATION. tI 6. PROVIDE WALL MOUNTED OCCUPANCY SENSOR MOUNTED AT 48" EQUAL TO HUBBELL UGHTHAWK SERIES, SHALL BE PROVIDED WITH TOGGLE ON /OFF SWITCH. 7. PROVIDE AND INSTALL CURRENT UMITiNG DEVICE EQUAL TO CONTECH REG6. TRACK UGHTING SHALL BE WIRED IN A MANNER IN WHICH ONLY ONE CURRENT UMIIING DEVICE IS NEEDED PER HOMERUN. 8. CONNECT CIRCUIT THROUGH UGHTING CONTACTOR LC1 CONTROLLED BY SWITCH "b ". REFER TO UGHTING CONTACTOR SCHEDULES, UGHTING CONTROL DETAIL AND SWITCH BANK DETAIL ON THIS SHEET FOR ADDITIONAL INFORMATION. 9. PROVIDE AND INSTALL CURRENT UMIIING DEVICE EQUAL TO CONTECH REG5. TRACK UGHTING SHALL BE WIRED IN A MANNER IN WHICH ONLY ONE CURRENT UMIIING DEVICE IS NEEDED PER HOMERUN. 10. CONNECT NEW OR EXISTING EMERGENCY UGHTS, EXIT SIGNS AND NIGHT UGHTS TO EXISTING DEDICATED EMERGENCY CIRCUIT 'L -7'. EMERGENCY UGHTS, EXIT SIGNS AND NIGHT UGHTS SHALL BE CIRCUITED AHEAD OF ALL SWITCHING. 11. PROVIDE AND INSTALL CURRENT LIMITING DEVICE EQUAL TO CONTECH REG3. TRACK UGHTING SHALL BE WIRED IN A MANNER IN WHICH ONLY ONE CURRENT LIMITING DEVICE IS NEEDED PER HOMERUN. 12. EXISTING UGHTING IN BACK OF HOUSE SHALL REMAIN. MAINTAIN EXISTING UGHiiNG BRANCH CIRCUIT (L -19). CONNECT CIRCUIT THROUGH UGHTING CONTACTOR LC3 CONTROLLED BY SWITCH "a ". REFER TO UGHTING CONTACTOR SCHEDULES, UGHTING CONTROL DETAIL AND SWITCH BANK DETAIL ON THIS SHEET FOR ADDITIONAL INFORMATION. 13. EXISTING EMERGENCY UGH11NG IN BACK OF HOUSE SHALL REMAIN. 14. CONNECT CIRCUIT THROUGH UGHTING CONTACTOR LC3 CONTROLLED BY SWITCH "a ". REFER TO LIGHTING CONTACTOR SCHEDULES, UGHTING CONTROL DETAIL AND SWITCH BANK DETAIL ON THIS SHEET FOR ADDITIONAL INFORMATION. LIGHTING GENERAL NOTES A. UGHT FIXTURES SHOWN FADED AND LABELED 'EX' ARE EXISTING TO REMAIN. B. ALL WIRING DEVICES (RECEPTACLES, SWITCHES, ETC.) AND COVERPLATES SHALL BE WHITE, NO EXCEPTIONS. C. UGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE THRU- WIRING WHEREVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE UGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. UGH11NG FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE THRU- WIRING, ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. D. UGHTING CIRCUITS UP TO 100' -0" IN LENGTH SHALL U11UZE #12 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 1011 -0" TO 150' -0" IN LENGTH SHALL U11UZE #10 CONDUCTORS MINIMUM. UGHTING CIRCUITS FROM 1511 -0" TO 250' -0" IN LENGTH SHALL U11UZE its CONDUCTORS MINIMUM. UGH11NG CIRCUITS ABOVE 251' -0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. E. ELECTRICAL CONTRACTOR'S BID SHALL INCLUDE THE INSTALLATION OF ALL UGHT FIXTURES AND ASSOCIATED LAMPS FURNISHED BY OWNER. SOME FIXTURES REQUIRE ASSEMBLY. E.C. IS RESPONSIBLE TO ENSURE THE ADJUSTABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. IF THE CEIUNG SYSTEMS ARE FIRE RATED, E.C. SHALL CLOSELY COORDINATE RECESSED FIXTURE REQUIREMENTS WITH OWNER AND SUPPUER TO MAINTAIN THE FIRE RATING OF THE CEIUNG. F. FIXTURES INSTALLED IN FURRED SPACES SHALL BE CONNECTED BY MEANS OF FLEXIBLE CONDUIT AND "AF" WIRE RUN TO A BRANCH CIRCUIT OUTLET BOX WHICH IS INDEPENDENT OF THE FIXTURE. EMERGENCY AND EXIT FIXTURES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST NATIONAL ELECTRICAL CODES. H. ALL NIGHT UGHTS (SHOWN WITH "NL" DESIGNATION) SHALL BE WIRED AHEAD OF SWITCHING. I. EMERGENCY FIXTURES, EMERGENCY BALLASTS SHALL BE PROVIDED WITH AN UNSWITCHED "HOT" TO PROVIDE CONTINUOUS POWER TO BALLAST EVEN WHEN FIXTURE IS OFF. J. EXIT/EMERGENCY LIGHTS AT THE STOREFRONT SHALL BE CEIUNG MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON -SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. K. IT SHALL BE THE E.C.'S RESPONSIBIUTY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE E.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. L. DISCONNECT AND DISCARD ALL EXISTING ELECTRICAL EQUIPMENT AND DEVICES, WIRING, CONDUIT, UGHT FIXTURES, ETC. NOT BEING REUSED. 2 HOUR OVERRIDE - OTIMER SWITCH TO CONTROL 11MECLOCK POLE #1 - LC1 -o 0- Oa ®-0 O ® DETAL NOTES 1. REFER TO CONTACTOR SCHEDULE LC1 ON THIS SHEET FOR CIRCUITS TO BE CONNECTED TO CONTACTOR. 2. REFER TO CONTACTOR SCHEDULE LC2 ON THIS SHEET FOR CIRCUITS TO BE CONNECTED TO CONTACTOR. 3. REFER TO TiMECLOCK SCHEDULE ON THIS SHEET FOR CIRCUITS TO BE CONNECTED TO 11MECLOCK. SWITCH "a" SWITCH "b" /0 • SALES/BOH UGHTING TRACK/DISPLAY UGHTING II STOREFRONT l AND SIGNAGE LIGHTING CONTROL SCHEMATIC SCALE: NONE LIGHTING CONTROL DESIGN INTENT EVENT: NORMAL BUSINESS HOURS (HOURS TO BE DETERMINED BY OWNER) - UGHT SWITCHES AT THE UGHTING SWITCH BANK SHALL CONTROL THE UGHT FIXTURES. EVENT: CONCLUSION OF BUSINESS DAY (TIME TO BE DETERMINED BY OWNER) - 11MECLOCK SHALL SWEEP "OFF" ALL LIGHTS EVENT: AFTER BUSINESS HOURS UGHT FIXTURES SHALL "OFF". OFF " . IF AFTER HOURS CONTROL OF THE UGHT FIXTURES IS DESIRED, THE OVERRIDE SWITCH SHALL SERVE AS AN OVERRIDE SIGNAL TO THE TIMECLOCK AND THE UGHT SWITCHES SHALL BE CAPABLE OF CONTROLLING THE UGHT FIXTURES AGAIN (2 HOUR OVERRIDE MAX). EVENT: BEGINNING OF BUSINESS HOURS - UGHT SWITCHES AT THE UGHTING SWITCH BANK SHALL CONTROL THE UGHT FIXTURES. IT '-T ra::a.. ""��::�xac::a:, n..a.,.:::,• �•:u:,::a:: r::.:.:xr• ��� •":::::a....:::xh:::�r::.:::.:: N FELD VERFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR TENANT PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR TENANT AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR TENANT OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. TIMECLOCK "TC" CIRCUITS NUMBER OF CLOCKS 4 CONTROL REMARKS: Wall Switch 'b' Mount in Nema -1 Enclosure POLE CIRCUIT DESCRIPTION 1 L -11 LIGHTING CONTACTOR LC3 2 L -11 LIGHTING CONTACTOR LC1 3 L -11 LIGHTING CONTACTOR LC2 4 -- -- SPARE LIGHTING CONTACTOR "LC1" NUMBER OF POLES: 6 CONTROL REMARKS: Wall Switch 'b' Mount in Nema -1 Enclosure POLE CIRCUIT DESCRIPTION 1 L -4 SALES TRACK LIGHTING 2 L -6 SALES TRACK LIGHTING 3 L -8 SALES PENDANT LIGHTING 4 L -25 PERIMETER FIXTURES 5 L -29 PERIMETER FIXTURES 6 -- -- SPARE LIGHTING CONTACTOR "LC2" NUMBER OF POLES: 4 CONTROL REMARKS: TIMECLOCK Mount in Nema -1 Enclosure POLE CIRCUIT DESCRIPTION 1 L -1 SIGNAGE 2 L -5 STOREFRONT RECEPTACLES 3 L -12 STOREFRONT DOWNLIGHTS 4 L -14 STOREFRONT TRACK LIGHTING CONTACTOR "LC3" NUMBER OF POLES: 4 CONTROL REMARKS: TIMECLOCK Mount in Nema -1 Enclosure POLE. CIRCUIT CRIPTION DESCRIPTION S 1 L -10 SALES GENERAL LIGHTING 2 L -19 STOCK GENERAL LIGHTING 3 -- -- SPARE 4 -- -- SPARE X 'X Ex tai X1 •■ P •r • \r (L -12 L -10) MI NW 17 • ik 'ik NV •Ir a I. 'i► NI NI ..1 4' (L' 14) ELECTRICAL LIGHTING FLAN 26bCidasnih r on S ate Nonrlastdenuat liner •y Cpde Co iffilleel.Foffirii Interior Lighting Summary :300610:s 'pion Slats Nan is clittat EnelDyoade bore r LTG -INT geasedJue3a01 Project Info'.: ProjettAadress ae resale, Dale 7/25/2012 all s.uihu.ntoz aars.rar, sp'ne. %6224 For Stttdlrg Depertmant ISS: Sae 4a 901ea: AsplkanWama Apphcanf. Addross'. ApphCen[ Phone Project Description 0 flew Blnlding 0 Addnlon EV Alteration 121019R5 Ir.09.0ed Indicate corrtroisgsectlons 1513) incuding cornnOsSfoning requirements on plans: i "oi11i71i621 e;Option O proniiptivg Uglt:rgl P7,1w.v gAI:tce' 13 Sys rns , 0ysis (Se2(4.1a6h.60n Cheddia.. M1�r). Bn4c3lE PresUlptiya $ LP:AS Sce5412aFlb onpfr..7•M i Alteratioil'ExcepUons (checkappropneto,lrax -Sao k122.2) D E1€frhanges are:bein9 made.to:the!to0lilOi late sstlen60 'to-t4thsflxn,res't1 @W, installed' wattega. notnicieesed .5spec snotchangeti.. Maatimgm Ailawed Lighting Wattage. 14, oation (floorJ oom no:)' Occupancy DesrnpfiorI. 40090. vyae =_per'it ?''' /tit ale ftx Allovired x Area SALES' RETAIL 133- 1481.0 1969.7 aii.ali PTSatar lraaeltierb. a. MM.Lais 1.40 793.0 1110 -.2. BALES: 1,000 a 't ae006dl•L:26.e 4t4. altoeino. 8e=I 1.00,. 1000.0' 1000.0. SALES .Tabe 15- 1,r:eontnate'eia I: 480.0 48(.0 sages a - TNick .4lEl' 1ne 1. 60:0, G VOLT HALOGEN stecK' ax atzia Elekr Done 18. 6:4.0 3.15:2.0 "From Table 151; ?ov:rj- .lucumsntall ekcaptfon$ on farm.LTGI,I'A Tate) Allowed Watt$ 4070''.9. Locaudn (fioor/room nd':):. FutureDes:nphon; NUmberor :Fixturss. Wahsa' Fixn.re., Watts PropOSad sAiEs:. - - Voodoo!. Hone Law 2. 6 :0: 1Zi:0 sat.ES, tr aeoes eii':!Dnr,ntisp.i 25: 1513.1 625:0. BALES: D T ek LAELOL1.e. 1 10.0 360.0 SALES D snack Lighting I: 480.0 48(.0 sages a - TNick .4lEl' 1ne 1. 60:0, G VOLT HALOGEN stecK' ax atzia Elekr Done 18. 6:4.0 3.15:2.0 aasranm ex - e0V1 igJiL m4,snetieh 1. 75.0 75.0 0 . 1Q yeq 15134 Display /exhiblspecial Indicate separate controls - E1, E2 -- 0 1513.5: Fxderior: shut -off Schedule with type and features indlcate.location CONTECI4 TPTIV W/ SPCP'IlOWr iiOU6I4fi1 CLEAR TI M PHALLI'. CD M -t 26/ PA4! 3M 1'I./IIG f1'IG (a) timer wibackup . Indicate location: eX ®XI w XI ELX -INVRC PeCESSEA LED EDGE LICE SIGN Total Froppsad Wahs.may mot exceed Total Allowed Waits fde Iih erlor. T Cal PrcpeSed WattS $244,.0 Notes: 1 For proposed Fo0ure De cnpSorir ndhcate 5xture: type lamp dype(Gg.. T6 j,. number pllemps inthe t*re., a 0ballest type -(if m�lidsd)'; For tra k fightfn$ 91st the lerglh dlthe.treck (in teet):in'additien to tits hxtLre, lamp, arid ballast intermation. 2 For proposed Watts /F2lula use menu acturars listed moxrinurn Inplh waitago of the hldure (not sh'hpf r the lamp Wattage) aid other riterra as peclhedm Section 1:530 For Hari} -vered balfests prtIsfi. the defiutt table fl the NREG Tecli0cal Re erenee Manual: may alsobeused Forfracklighunghstihi ralarmacthellummarreWat tagaorleggthofteck ;mulhpfdbySO,.or:as'. applr.ab(9 the wo0ege;]7f ciorent Ilmihfi¢ der es or Whet 6Nlsformel 3 Listelltcdltas. For oxempt Itghting: Hite secti nand excOPhen: number id:leeae Watty/Fo0ure; blank I/4" • I' -0n REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. PI4.E COPY Permit No 1}1%'' i24:7o$ PIP.n r 'iiew approval is subject to errors and omissions. 34 of construction documents does not authorize to ,. olation of any adopted code or ordinance. Receipt (11 i pproved Field Cop and is ac knowiedged: By Date: 9 ) City OrtTb kw it a BUILDING DIVISION 2006 Washing ton State Nonresidential Energy Code Compliance.Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK ewied July W/ 2UUb w35timen Sale.NO'resdenla trhsiyy' Com C011013nce:tone Prefect Address xezoeo1es (Date 7%25/2012. The 'Mating i fcrmatien is necessary to check a petrol application far compliance with the lighting; motor end - Transformer requirements in the 2006 Washington State Nonresidential .Energy Code. Applicability Code (Yes, no, n,a.) Section (Component Infonnation Require( : Location on Plans : Building D:pertment Noes LIGHTING .CONTROLS (Section 1613 'UNIVERSAL PAR HOLDER ?RACK FIAp nNi/Na W'Nii- IVJIMODEL TYPE 1'ea 1513.1 Local control/access Schedule with: type, indicate locations- 5l SALES DISPLAY yea 1513.2 Area controls Maximum aims per switch El - n, 15133 Daylight zone control Schedule with type and featres indicate locations TECH LIGFTNG 1004Y- rAIS-W-C ton- ru-R -J G VOLT HALOGEN -- -- vertical glazing indicate vertical glazing on plans K 4 ' LONG (1) LAMP 6TItlP FLUORESCENT LIGHT PIXTUNE 67000100M UIMNM16E PENDANT HUNG MN JACK CHAIN COORDNATL' WIR4 SMOG SiELVNG LAYOUT, UM ONLY UI 4 STOCK 1445 OPEN CEILING METALUbr: 156232- UVN-ED/I P32TIVILIGIVAiLTO HV I20V overhead . glazing: Indicate overhead glazing on plans 0 . 1Q yeq 15134 Display /exhiblspecial Indicate separate controls - E1, E2 -- 0 1513.5: Fxderior: shut -off Schedule with type and features indlcate.location CONTECI4 TPTIV W/ SPCP'IlOWr iiOU6I4fi1 CLEAR TI M PHALLI'. CD M -t 26/ PA4! 3M 1'I./IIG f1'IG (a) timer wibackup . Indicate location: eX ®XI w XI ELX -INVRC PeCESSEA LED EDGE LICE SIGN (b)photocell. Indicate Ideation,. -- -- I 1513.8 Inter. auto shut -off Indicate location n:a.. 15 .6.1 (a). occup. sensors Schedule with type and locations • 1 gram EAIQR 6PEA1R 6PeZ Yee 15136.2 (b) auto switches Schedule with type and features (back -up, overnde capability); Indicate size of zone' on plans El. yes 1513.7 Commissioning Indicate requirements fa lighting contrds commissloning El EXIT SIGNS 1514) yes 1514 Max watts Indicate watts fa each: exit sign E1 LIGHTING POWER ALLOWANCE (Section 1630-1632) yea 1531 Interior Lighting Summary Forrn Completed and attached. Schedule with fiMu lamps, ballasts, watts per failure: E1 • C n.a. 1532 Exterior Lighting Summary Fern Completed and attached: Schedule with fixture types; lamps; ballasts watts per fixture' E Y LIGHT 120v 4LALOaeJi LAM(" G MOTORS (Section 1611) n a. 1511 Ioec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERSySection 1540) yes 1540 (Transformers (indicate size and efficiency: 1E2,, E3 N "no" is circled for anyquestion, provide explahation: 2005 Washin ton State Nonresidential,Enert Code :Com•IlanceForm Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2t/U6 w3aingkn Seale Nnrlesd Lliat 3rg C'Dde'L'ti'npienretorrims Netted 0910°r Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting In Section 1512, shall ;cq.mplyWith this section.: Where occupancy sensors are':ofted, they :shall have the features' listed In Section 1513.6.1. Where automatIotime switches are cited, they shall have the features !listed' in Section 1513.8.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided tenth lighting controls located within that space. The lighting controls whether one or more, shalt be capapie: of turning off all lights within the space, The controls shall be readily accessible, atthe point of entry /exit, to personnel occupying or using the space EXCEPTIONS: Tho following lighting controls may be centralized in ireMote locations:: 1. Lighting controIe for spaces Which must be used as a whole:. 2. Automate controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security 1513.2 Area Controls::. The maximum lighting 'power that may be controlled from a single switch or automatic control shall not ekceed that which is provided bye -20'em pore circuit loaded to not more than '60%. A master: control may Installed provided the Individual switches retain their capability to function Independently. Circuit breakers may not be used . as the sole means of switching. EXCEPTIONS: 1. Industrial:or manufact tring : process areas,. as may be required for production. 2. Areas less then 5% of the building footprint for footprints beer 100;000 ft'. 1513.3 Daylight Zone Controls All days ghte'd' zones, as defined In Chapter 2, both under overhead glazing: and adjacent to vertical glazing, shall be provided with Individual controls, or:daylight -: or occupant - sensing automatic controls; which control the lights independent of general area lighting. Contiguous daylight . zones adjacent to vertical glazing. are . allowed to be controlled by a single controlling device provided that they do not Include zones facing more than two adjacent cardinal orientations (Le. north, east, south, west): Daylight.zones uhder overhead glazing more than 15 feet from the perimeter shall controlled separately from daylight zones adjacent to vertIcel glazing. EXCEPTION; Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate swltdh for general area lighting, 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently: of general area lighting . 1513.5 Automatic Shut -off Controls, Exterior:.LIghting for all exterior epplioations shall have automatic controls nape die of timing off exterior lighting when sufficient daylight .I0 available or when the lighting Is not required during nighttime hours Lighting not designated for dusk -to -dawn operation' shall be controlled by either. a. A: combination :of a photosensor and a tirne switch; or b. An astronomical time switch. Lighting designated tordusk -to -dawn operation shall bey controlled by an astrortoin foal time switch or photosensor..All time scotches shall be capable of retaining programming and the time setting during loss of power for a period eat least 10 hours. EXCEPTION Lighting for covered vehicle entrances or exits from buildings or parking structures where required far safety, security, or eye adaptation. 1513.6 Automatic but Off Controls, Interior; Buildings ngs greater n . neater the .. 5 ODD ft' and all 008001.ciassrooms shell be equipped with separate eutomatic controls t o shut oft the lighting during unoccupied tours. Within these buil dings, all office areas less than 300 ft' enclosed by walls or ceiling- hefghtpartftions, and all meeting and conterence rooms, and all school classrooms shall be equipped with occupancy sensors that cornpiy wih.Seotion 1513.6.1. For other spaces, automatic controls may be an occupancy sensor,' time Switch or other device capable of automatically shutting off lighting. eve DT Al C• 1 A raaclhat:m i,at.Fw,r rm. t ,. ICIu illuminated' In -a: manner requiring manual operation of the lighting:. 2. Emergency lighting. systems. 3 Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas In which medical or dental tasks are performed are exempt from occupancy sensor (requirement. 1513,6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically timing off all the lights in an area, .no, more than. 30 minutes after the area has been vacated: Light fixtures controlled by occupancy sensors shall have a wall mounted, manual switch capable of turning off lights when space Is occupied. EXCEPTION: OccUpartcy sensors in stairwells are allowed to have two step lighting (high -light and low- light) provided the control falls Witte high -light position. 1513.6.2 Automatic Time Switched Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and Incorporate an automatic holiday "shut-off' feature, which turns off all loads for at least: 24 hours and then resumes normally scheduled operations: Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours; if power Is interrupted. Automatic time switches shall incorporate en over -ride switching device which: a. Is readily accessible, b. is located so that a person using the device can seethe lights or the areas controlled: by the switch, or so that the . area being Illuminated Is annunciated; c. is manually operated, d allows the lighting to remain on for no more than 2 hours when an over -ride is Initiated; and e. controls an area not exceeding 5000 ft' or 5% of the building footprint forfootprinb over 100,000 ft', whichever is greater 1513.7 Commissioning Requirements: For lighting controls which Include daylight dr occupant sensing automatic controls, automatioshutoff controls, occupancy sensors, or automatic time switches the lighting controls shall be tested to ensure that control devices. components, egyfpment and systems are calibrated, adjusted and operate In accordance with approved plans and specifications' Sequences of operation shall be functionally tested to ensure they operate In accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the. owner. Drawing notes shall require commissioning in accordance with this Paragraph. 1514 Exit Signet Exit signs shall have an input power demand of 5 Watts or less per *ign. Motors - General Requirements 1511 Electric Motors: All. permanently wired polyphase' motors of 1 hp or more. Which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an Integral part of specialized process equipment 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 - TRANSFORMERS minimum efficiency of a low voltage dry-type distribution transformer shall be the Class .I Efficiency Levels for distnbutwn transformers specifieO In Tattle 4-2 of the "Guide for Determining Energy Efficiency for Distribution Transformers published by the National Electrical M ufac5, ers'Association (NEMA TP -1- 2002). SEPARATE PERMIT REQUIRED FOR: IP1Aechanical ❑ Electrical (Plumbing (was Piping City of Tukwila BUILDING DIVISION REVIEWED FOR CO FPP �CNEVC H AUG 08 2012 City of Tukwila Jam. BUILDING DIVISION CT)LIGHTING MASTER SWITCH BANK SCALE: NONE LIGHTING SCHEDULE 6YMDOL TYPE DE6AtlPTION MODEL LAIR* CD 111LO NEW D ,T►1T p 'UNIVERSAL PAR HOLDER ?RACK FIAp nNi/Na W'Nii- IVJIMODEL TYPE O 0 0 0 SALES /BOH SALES DISPLAY MASTER LIGHTS LIGHTS OVERRIDE 'a' 'b' SWITCH CT)LIGHTING MASTER SWITCH BANK SCALE: NONE LIGHTING SCHEDULE 6YMDOL TYPE DE6AtlPTION MODEL LAIR* EXS 111LO NEW D ,T►1T p 'UNIVERSAL PAR HOLDER ?RACK FIAp nNi/Na W'Nii- IVJIMODEL TYPE COMM CTLI'b PHILLIPS 03I4-I 16/ PAR SS/ FLAK &PK 4444 mac LIGHTING TRACK- PINISHo aunt TRACI4 L12P/2' -0', LT4P/ 4'-0' MP/ l i. -O'. LTSP/ i'-0' MINI CONNECTOR' LA-2P eI#lrr4P.E GONDWT END RCD& LA-SP (2'-0' LONG TRACK LIGHT (AM AT FIXTURE) (4'-0' LONE TRACK LIGHT (AM AT SION.1 ) COMM Q4 LT2P/ 2'-0' LT4P/ 4'-0' LTbP/ •'-0' LTSP/ 47-0' NOT APPLICABLE -- -- 113•'-0' 2 -41-0' P P PIIDANR HUG LttiNT WM4 LAMP MOUNTING WITH 6'-0' STRAIGHT OLAtCK CORD WITH AIRCRAFT CABLE (eOT1 Pt • 41-0 Apr.) • G.C. TO 1'tIW41ew INSTALL 0) NEW MATCHING PIEIDAHT LIGHT POMMES mom TO KNDORF SUPPORT TECH LIGFTNG 1004Y- rAIS-W-C ton- ru-R -J G VOLT HALOGEN -- -- 2 L--,---_1 K K 4 ' LONG (1) LAMP 6TItlP FLUORESCENT LIGHT PIXTUNE 67000100M UIMNM16E PENDANT HUNG MN JACK CHAIN COORDNATL' WIR4 SMOG SiELVNG LAYOUT, UM ONLY UI 4 STOCK 1445 OPEN CEILING METALUbr: 156232- UVN-ED/I P32TIVILIGIVAiLTO HV I20V -- -- 0 . 1Q Ice 6A/11 Ad PbCURE K', KW DE612144716 EP'lRmBiCY LIGHTING METALUX tI M232- OGi -G -ELS UVI -II MPK 277V RATED PIXIIIR P32TDJrLIMIWALTO 14v 10V -- -- 0 ® N PeCe86E0 DCIIN -IGFR FOR 11I111J WPM CONTECH 0 114 DIA. APENNINE REMICK* TRIM. GC. ro PANT FLANGE TO MATCH CEILING P114I6H IN DRYWALL COMMON, ONLY. CONTECI4 TPTIV W/ SPCP'IlOWr iiOU6I4fi1 CLEAR TI M PHALLI'. CD M -t 26/ PA4! 3M 1'I./IIG f1'IG eX ®XI w XI ELX -INVRC PeCESSEA LED EDGE LICE SIGN ASTRALITE ELX- mate.- t -IeG -U 1T-PJM 2b A114GAP LED IL lQ4 -- -- I ens) w X3 UNIVERSAL RIMIMI 4CY EXIT SIGN teary.A A6TRALITE WIiH KiT 22 AE�AP LED I .1124 • 1 gram EAIQR 6PEA1R 6PeZ TAD. FLUSH MOII1T/ SUWACE M U41' DETA SEE PETAL 16 E 6f34 OR E(.f AL 2 MI-141 3 eORAIE426 i EXTOG C TOILET ROOM LIGHT / PM COMBO woe WW/ LI214f 0211NATION I2oV t00 Alit -- -- I • C 0 EM EXISTING TO Nd1AN E Y LIGHT 120v 4LALOaeJi LAM(" G 2 EXISTING TO 'REMAIN 2 va.T M= AO CALCIUM EATIERY WITH (2) HEADS 12 VOLT (2) PAR M -- -- 3 EXERS NM 1. ALL 1RACKt.IGIff8 ARE TO OE 2. AU. STOREFRONT LIGHTS AND TIMM TO EE SET TO d0 al I -14GUN Audit STORE CLOSING. 3. ALL PIXITINE6/ACCEd6ORE6 4. LIGHTING ISUPPLIER TO VI RIY CENTEINED ON WL*U. I9XMWE6 MO AIM TO Be ON A 24 -HOUR TI MM SET OY SC. I -140 t PRIOR TO INTONE OPEIIINO, AND TWINING O.. �� 01 % TO OR WI417! IN COLOR ON PANTED RJANTME6 FOR IbwrNG Ti E iNEdIINED AMOUNT. 9O% SET- i -19 -12 SEAL: AEROSOLES SHEET TITLE: ELECTRICAL LIGHTING PLAN REVISIONS: NO: DATE: SEATTLE, WASHINGTON 98188 BY: PROJECT NO: DRAWN BY: 12874.00 SCHMID, SOSA SHEET OF POWER CODED NOTES 1. COMMUNICATIONS ( VOICE/DATA) HEADEND EQUIPMENT TO BE LOCATED AT MANAGER'S DESK MILLWORK. VERIFY LOCATION OF EQUIPMENT WITH COMMUNICATIONS CONTRACTOR. 2. ROUTE 3/4" CONDUIT TO VOICE/DATA COMMUNICATIONS EQUIPMENT BOARD. 3. TRENCH 3/4" CONDUIT FOR VOICE/DATA IN FLOOR TO NEAREST WALL EXTEND TO CEIUNG SPACE AND TERMINATE AT COMMUNICATION EQUIPMENT BOARD. 4. TRENCH CONDUIT IN FLOOR TO NEAREST WALL. EXTEND TO CEIUNG SPACE AND ROUTE TO DESIGNATED PANEL 5. SEE MANAGER'S DESK ARCHITECTURAL MILLWORK ELEVATIONS FOR LOCA11ON OF MUSAK UNIT. LOCATE RECEPTACLE AT UNIT LOCATION. 6. ELECTRICAL AND COMMUNICATION DEVICES AT CASH WRAP MILLWORK TO BE LOCATED BEHIND FALSE PANEL 7. PROVIDE SHOW WINDOW RECEPTACLES FLUSH MOUNTED IN CEIUNG. CONNECT CIRCUIT THROUGH NEW CONTACTOR 'LC2' WHICH IS CONTROLLED BY NEW 24 HOUR/7 DAY 11MECLOCK TC. 8. FIELD VERIFY EXACT CONDITIONS AT MANAGERS DESK LOCA11ON. COORDINATE BEST LOCATION OF RECEPTACLES WITH ARCHITECT AND /OR TENANT PROJECT MANAGER PRIOR TO INSTALLING. 9. EXISTING FIRE ALARM DEVICES (IF APPLICABLE) SHALL REMAIN. THIS INCLUDES BUT IS NOT LIMITED TO HORN /STROBES, PULL STATIONS, SMOKE DETECTORS AND DUCT MOUNTED SMOKE DETECTORS. MAINTAIN CONNECTION TO EXISTING FIRE ALARM SYSTEM AND PROTECT THROUGHOUT CONSTRUCTION. 10. REFER TO ELECTRICAL RISER DIAGRAM ON SHEET E -3 FOR MORE INFORMATION ON THE ELECTRICAL DISTRIBUTION EQUIPMENT. 11. PROVIDE QUAD RECEPTACLE FOR SECURITY SYSTEM. COORDINATE EXACT MOUNTING HEIGHT AND LOCA11ON PRIOR TO ROUGH —IN. 12. CONNECT CIRCUIT THROUGH LIGHTING CONTACTOR LC1 CONTROLLED BY SWITCH "b ". REFER TO UGH TING CONTACTOR SCHEDULES, UGH TING CONTROL DETAIL AND SWITCH BANK DETAIL ON THIS SHEET FOR ADDITIONAL INFORMATION. 13. UTILIZE EXISTING RECEPTACLES IN SALES /BOH AREA WHEREVER POSSIBLE. OTHERWISE, REMOVE DEVICE, CONDUIT AND WIRING BACK TO PANEL IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO ENSURE THAT ANY DOWNSTREAM ELECTRICAL DEVICES BE RECONNECTED TO AN EXISTING INTACT BRANCH CIRCUIT. 14. EXISTING HVAC EQUIPMENT SHALL REMAIN. MAINTAIN AND PROTECT ALL ELECTRIC CONNECTIONS AND ASSOCIATED DISCONNECT SWITCHES, CONVENIENCE RECEPTACLES, ETC. POWER GENERAL NOTES A. ANY PENETRATIONS THROUGH FIRE — RESISTANT/RATED WALLS, PARTITIONS, FLOORS, AND CEILINGS SHALL BE FIRESTOPPED USING APPROVED METHODS TO MAINTAIN THE FIRE RESISTANCE RATING. B. ELECTRICAL CONTRACTOR TO PROVIDE A TYPED PANEL DIRECTORY WITH ALL CIRCUITS ACCURATELY LISTED PRIOR TO STORE OPENING. C. ELECTRICAL CONTRACTOR SHALL PROVIDE JUNCTION BOX AND RACEWAY FOR THERMOSTATS AT 60" A.F.F. THERMOSTATS AND TEMPERATURE SENSORS INSTALLED AND WIRED BY MECHANICAL CONTRACTOR. COORDINATE EXACT LOCATIONS WITH MECHANICAL CONTRACTOR. TYPICAL OF ALL. D. ALL CONDUITS SHALL BE CONCEALED IN WALLS AND OUTLET BOXES SHALL BE FLUSH WITH FINISHED WALL UNLESS OTHERWISE NOTED. E. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES AND ORDINANCES AND LANDLORD'S TENANT CRITERIA MANUAL F. RECEPTACLES AND DATA/TELEPHONE SHALL BE MOUNTED +18" A.F.F. UNLESS OTHERWISE NOTED, NO LOWER THAN +15" A.F.F. TO BOTTOM OF DEVICE. G. RECEPTACLE CIRCUITS UP TO 100' -0" IN LENGTH SHALL UTUZE #12 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS FROM 101' -0" TO 150' —O" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS FROM 151' -0" TO 250' -0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS ABOVE 250' -0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. H. SECURITY SYSTEMS CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OTHER SECURITY SYSTEM CONNECTIONS. I. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REVIEW ALL ARCHITECTURAL DRAWINGS, ELECTRICAL DRAWINGS AND NOTES TO INSURE THAT ALL ELECTRICAL REQUIREMENTS ARE MET. J. ALL POWER AND ALARM WIRING FOR EXIT DOORS SHALL BE CONCEALED IN DOOR FRAME. K. DUCTWORK AND PIPING SHALL NOT BE ROUTED OVER ELECTRIC PANELS OR TRANSFORMERS. L PROVIDE NAMEPLATES ON PANELBOARDS, DISCONNECT SWITCHES, TRANSFORMERS, ETC. INDICATING EQUIPMENT DESIGNATION OR EQUIPMENT SERVED AND VOLTAGE. M. VERIFY LOCATION OF FLOOR OUTLETS WITH ARCHITECT PRIOR TO ROUGH —IN. N. DATA/TELEPHONE CONDUIT SHALL BE 3/4" MINIMUM UNLESS OTHERWISE NOTED ON DRAWINGS. 0. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN THEIR BID, COSTS REQUIRED TO MAKE THEIR WORK MEET EXISTING CONDITIONS. P. ALL WORK AND MATERIAL SHALL BE IN ACCORDANCE WITH THE LANDLORD'S TENANT CRITERIA MANUAL ALL CONTRACTORS SHALL OBTAIN A COPY FROM THE LANDLORD'S TENANT COORDINATOR FAMIUER WITH THE REQUIREMENTS CONTAINED WITHIN PRIOR TO BIDDING THE JOB. WHERE LANDLORD'S REQUIREMENTS CONFUCT WITH CODES OR ORDINANCES THE STRICTEST INTERPRETATION SHALL APPLY. L a nss- —I 23) 21) PROVIDE UGHT Fl CASHW .........�::„... , ...., ,............. -,. . ,,,a . _ „ .....w...„, iJ .....a,µ (L -21,23 ELECTRICAL FOUJEIR FLAN 1/4" • 11•0" cos REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC AUG 08 2012 City o r "M. BUILDING DIVISION FELD VERFY ALL �N$ DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR TENANT PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR TENANT AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR TENANT OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. NPORTANT DEMOLMON NOTE ELECTRICAL CONTRACTOR SHALL VISIT SITE AND VERIFY EXISTING CONDITIONS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL ELECTRICAL DEVICES (UGHT FIXTURES, RECEPTACLES, SWITCHES, ETC.) AND EQUIPMENT INCLUDING CONDUIT AND WIRING BACK TO PANEL, THAT IS NOT BEING REUSED. NOTHING SHALL BE ABANDONED IN PLACE. 90% SET- 1 -19 -12 a 12 W W z I VJ O v CC �z I Y WO W -' © rii65 z 0 i '- W W OI o • N O i O a� <. 1, Y i 1R§a SEAL: AEROSOLES JUL 252012 03 co Q OO)i I.J • � � Z wN O = N W O Z I O • W Z � Op V1 Q U Q � o1-3 W � O W L- Z V� 1• X O�WW co MW to � 1— SHEET TITLE: ELECTRICAL POWER PLAN REVISIONS: NO: DATE: BY: PROJECT NO: DRAWN BY: 12874.00 SCHMID, SOSA E 2 SHEET OF NOTE: EQUIPMENT SHOWN FADED AND DASHED ARE EXISTING TO REMAIN. LANDLORD ELECTRIC ROOM-10- FLOOR 200AS /3P /200AF LANDLORD'S SWITCHBOARD 277/480V, 30, 4W -- AEROSOLES TENANT SPACE 1 0 - EXISTING 11 PANEL H L 1- --iLC1 1 1 120/208V 30,4W 225A BUS: 1200A MLO 0 42 POLE j TO TELEPHONE .,,o-- DISTRIBUTION T 30kVA LC2 FACP .� ELECTRICAL RISER DIAGRAM SCALE: NONE EXISTING TELEPHONE 1 EQUIPMENT BOARD TTB 18 "Wx4'Hx 1 3 /4 "TH FLOOR ® CODED NOTES 1. EXISTING 200AS /3P MAIN SWITCH SHALL REMAIN. PROVIDE NAME PLATE TO READ "AEROSOLES ". NAMEPLATE SHALL BE BLACK WITH 1" HIGH WHITE LETTERS. LABEL SHALL BE PERMANENTLY ATTACHED TO EQUIPMENT. 2. EXISTING ELECTRIC UTIUTY METER SHALL REMAIN. E.C. SHALL CONTACT UTIUTY COMPANY TO TRANSFER ELECTRIC SERVICE INTO OWNER'S NAME. PROVIDE NAME PLATE TO READ "AEROSOLES ". NAMEPLATE SHALL BE BLACK WITH 1" HIGH WHITE LETTERS. LABEL SHALL BE PERMANENTLY ATTACHED TO EQUIPMENT. 3. EXISTING 200 AMP WIRE AND CONDUIT SHALL REMAIN. 4. EXISTING 240 VOLT, 3 PHASE DISCONNECT SWITCH SHALL REMAIN. 5. EXISTING PANEL L SHALL REMAIN. REUSE BREAKERS WHEREVER POSSIBLE. REFER TO SCHEDULE ON THIS SHEET FOR MORE INFORMATION. 6. EXISTING 100 AMP WIRE AND CONDUIT SHALL REMAIN. 7. EXISTING 30kVA, 208V TO 480V, REVERSE FEED, FLOOR MOUNTED TRANSFORMER SHALL REMAIN. 8. EXISTING WIRE AND CONDUIT TO HVAC EQUIPMENT SHALL REMAIN. 9. PROVIDE LIGHTING CONTACTORS AND TIMECLOCK. SEE UGHTING SWITCH BANK AND NOTES ON LIGHTING PLAN FOR MORE INFORMATION. 10. EXISTING PLYWOOD TELEPHONE EQUIPMENT BOARD SHALL REMAIN, 11. EXISTING CONDUIT FOR TELEPHONE/DATA FROM LANDLORD'S DISTRIBUTION POINT TO EXISTING TELEPHONE BOARD LOCATION SHALL REMAIN. PROVIDE ALL TELEPHONE/DATA CABLING AS REQUIRED FOR TELEPHONE AND DATA SERVICES. NO EXPOSED TELEPHONE CABLES IN RETURN AIR PLENUMS. E.C. SHALL CONTACT THE LOCAL TELEPHONE COMPANY TO ARRANGE FOR TELEPHONE SERVICE IN OWNER'S NAME. COORDINATE EXACT REQUIREMENTS WITH CONSTRUCTION MANAGER AND LANDLORD. 12. PROVIDE ALL REQUIRED TELEPHONE AND DATA CABLING AS REQUIRED BY AEROSOLES. NO EXPOSED TELEPHONE CABLES IN RETURN AIR PLENUMS. COORDINATE EXACT REQUIREMENTS WITH AEROSOLES' PROJECT MANAGER. 13. EXISTING FIRE ALARM BATTERY CABINET SHALL REMAIN. GENERAL RISER NOTES A. PARALLEL FEEDER CONDUCTORS SHALL BE CUT TO EXACTLY THE SAME LENGTHS AND SHALL BE FROM THE SAME FACTORY RUN. ALL CONNECTIONS FOR SAME SHALL BE TORQUED TO IDENTICAL VALUES. B. EXTERIOR ELECTRICAL WORK SHALL NOT ONLY BE WEATHERPROOF AND WATER - TIGHT, BUT SHALL ALSO BE RUST - RESISTANT. C. CONDUCTORS BELOW GRADE OR SUBJECT TO MOISTURE SHALL BE "XHHW -2 ". D. PROVIDE FACTORY SERIES COORDINATION FOR ALL CIRCUIT BREAKERS (INCLUDING ALL BRANCH BREAKERS), RELATIVE TO "UPSTREAM" BREAKERS, SO THAT ONLY THE BREAKER CLOSEST IN THE CIRCUIT TO THE LOAD TRIPS UPON AN OVERLOAD OR FAULT CONDITION. E. POWER DISTRIBUTION EQUIPMENT SUPPUER SHALL PROVIDE EQUIPMENT APPROPRIATELY RATED AND BRACED TO ACCOMMODATE THE AVAILABLE FAULT CURRENT AT THE UTIUTY COMPANY TRANSFORMER SECONDARIES. THIS SUPPUER SHALL ACCORDINGLY PROVIDE ANY RELATED CALCULATIONS SO THAT THEIR EQUIPMENT IS PROPERLY COORDINATED FOR THE AVAILABLE FAULT CURRENT. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THIS SUPPUER WITH COPIES OF THE ELECTRICAL DOCUMENTS AS REQUIRED SO THAT PROPERLY RATED/BRACED EQUIPMENT IS PROVIDED UNDER BASE BID. F. GROUNDING ELECTRODE WITH N.E.C., INCLUDING CONDUCTORS MAY NOT PROVIDED UNDER BASE G. EQUIPMENT GROUNDING WITH N.E.C., INCLUDING CONDUCTORS MAY NOT PROVIDED UNDER BASE CONDUCTORS SHALL BE PROVIDED IN STRICT COMPUANCE N.E.C. ARTICLE 250 AND TABLE 250 -66. THESE BE INDICATED ON RISERS OR SINGLE -UNES, BUT SHALL BE BID NEVERTHELESS. CONDUCTORS SHALL BE PROVIDED IN STRICT COMPUANCE N.E.C. ARTICLE 250 AND TABLE 250 -122. THESE BE INDICATED ON RISERS OR SINGLE -UNES, BUT SHALL BE BID NEVERTHELESS. H. WORKING CLEARANCES SHALL BE PROVIDED FOR ALL ELECTRICAL EQUIPMENT (SWITCHBOARDS, PANELBOARDS, TRANSFORMERS, STARTERS, DISCONNECTS, ETC. AS APPLICABLE) IN STRICT COMPUANCE WITH N.E.C. CHAPTER 1, PART B, SECTION 110- 26(a). LOCATIONS SHOWN ON FLOOR PLANS ARE SCHEMATIC AND DIAGRAMMATIC IN NATURE. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING COMPUANCE WITH THE ABOVE N.E.C. REFERENCE. THIS REQUIREMENT APPUES TO EQUIPMENT ON FLOOR PLANS AS WELL AS TO EQUIPMENT SHOWN ON RISER. I. HOLD ALL NEW OVERHEAD ELECTRICAL WORK AS TIGHT AS POSSIBLE TO THE BOTTOM OF THE OVERHEAD STRUCTURE. LOCATE ANY RELATED PULLBOXES SO THAT THEY WILL BE FULLY ACCESSIBLE AFTER ALL CONSTRUCTION WORK IS COMPLETE. AS WITH ALL WORK, COORDINATE IN ADVANCE WITH ALL OTHER TRADES. J. ROUTE FEEDER CONDUITS BELOW GRADE WHEREVER POSSIBLE. VERY UMITED SPACE EXISTS ABOVE ACOUSTICAL TILE CEIUNGS AND MANY, IF NOT MOST, OF THE SPACE ABOVE THE GYPSUM BOARD CEILINGS IS NOT AVAILABLE FOR RUNNING CONDUIT. STUDY ALL ARCHITECTURAL, STRUCTURAL & MECHANICAL DRAWINGS VERY CAREFULLY BEFORE LAYING OUT FEEDER ROUTES. K. ALL PANELS HAVE NEMA 1 ENCLOSURES UNLESS NOTED OTHERWISE. L. ALL PANELS ARE SURFACE MOUNTED UNLESS NOTED OTHERWISE. N. E.C. SHALL FIELD VERIFY EXISTING CONDITIONS, EQUIPMENT SIZES AND LOCATIONS, AND FEEDER SIZES PRIOR TO BEGINNING WORK AND REPORT ANY DISCREPANCIES FOUND. ELECTRICAL RESPONSIBILITY SCHEDULE ELECTRIC LEGEND SYMBOL G.C. DESCRIPTION SITE COND. LIGHTING FIXTURES FURN INST FURN FLUORESCENT 1' X 4' LUMINAIRE FURN INST EXIST NEW TEMPORARY POWER TRACK UGHTING IN LENGTH SHOWN & WITH NUMBER OF LUMINAIRES (HEADS) AS INDICATED PROVIDE ALL REQ'D. FACT. ACCESSORIES (T's, L's, X's, ENDS, PWR.FEEDS, FITTINGS, ETC. a o L O PENDANT MOUNTED HIGH -BAY LUMINAIRE le ® X SINGLE SIDED EXIT SIGN - CONNECT AHEAD OF SWITCHING KID m MAIN OVERCURRENT DEVICE IN LANDLORD'S ELECTRIC ROOM DOUBLE SIDED EXIT SIGN - CONNECT AHEAD OF SWITCHING LI EMERGENCY BATTERY PACK (W/ NUMBER OF HEADS INDICATED) - CONNECT AHEAD OF SWITCHING A,B,C LUMINAIRE/UGHTING FIXTURE TYPES LIGHTING CONTROL /SWITCHING a,b,c SWITCHING DESIGNATION NL nl UNSWffCHED NIGHT -UGHT FIXTURE ® X OCCUPANCY SENSOR (PIR) AUTO WALL SWITCH 0 48" AFF /AUTO -OFF & DIP SW. CHOICE OF AUTO OR MANUAL ON, 180 DEG. /1000 SQ.FT. (WS #WI -200, 0- 800W/120V, 0- 1200W/277V) $ SERVICE ENTRANCE FEEDERS TO LEASE SPACE SINGLE POLE SWITCH 3$ 3 -WAY SWITCH RECEPTACLES /MISCELLANEOUS OUTLETS 0 DUPLEX RECEPTACLE 40 DOUBLE DUPLEX RECEPTACLE ( "QUAD") DUPLEX GFCI RECEPTACLE - COUNTER HEIGHT OR SPECIAL HEIGHT - DO NOT FEED DOWNSTREAM OUTLETS FROM LOAD SIDE TERMINALS UNLESS SPECIFICALLY NOTED OTHERWISE ON DWGS. ( ) X FLUSH CEILING DUPLEX RECEPTACLE REFER TO RISER DIAGRAM DATA/VOICE v TELEPHONE OUTLET ®W TELEPHONE OUTLET - WALL PHONE (PROVIDE ONE CABLE DROP) O COMBINATION TELEPHONE /DATA OUTLET V DATA OUTLET MISCELLANEOUS 0 THERMOSTAT (LOW VOLTAGE) - FURNISHED, INSTALLED AND WIRED BY H.C. OUTLET BOX AND CONDUIT STUB -UP BY E.C. REFER TO RISER DIAGRAM TIMECLOCK & CONTACTORS TEMPERATURE CONTROL SENSOR (LOW VOLTAGE) - FURNISHED, INSTALLED & WIRED BY H.C. OUTLET BOX AND CONDUIT STUB -UP BY E.C. © X • INDICATES A DIRECT CONNECTION TO EQUIPMENT 01 X HEAW DUTY DISCONNECT SWITCH (NON- FUSED) 13 HEAW DUTY DISCONNECT SWITCH (FUSED) MOTOR 0-- X MOTOR OPERATED DAMPER (120V) FURNISHED AND INSTALLED BY H.C.) POWER AND INTERLOCK WIRING BY E.C. "v +` +`u HVAC CONTROLS RECESSED OR SURFACE MOUNTED PANELBOARD AS INDICATED ON PLANS PLYWOOD EQUIPMENT BOARD BY EC. (SEE DMSION 16 SPECIFICATIONS) X CIRCUIT BREAKER (NEMA 1 ENCLOSURE UNLESS INDICATED OTHERWISE) El v INDICATES GROUNDING BY EC. PER N.E.C. ARTICLE 250 MINIMUM TRANSFORMER igT g TELEPHONE EQUIPMENT & CABUNG ELECTRIC METER 1 DOOR OPERATORS /DEVICES 05 DOOR BELL WITH TRANSFORMER & PUSHBUTTONS AS SPECIFIED UNDER SPEC. SECTION 16810 GENERAL CONDUIT & WIRING FLUSH PUSHBUTTON FOR DOOR CHIME OR DOOR BELL (SEE SPEC. SECTION 16810) X _ FIRE ALARM 0- FIRE ALARM SYSTEM DUCT SMOKE DETECTOR TS X FIRE ALARM SYSTEM KEYED TEST SWITCH WITH LED. INDICATOR UGHT MOUNT NO HIGHER THAN 6' -0" A.F.F. TO THE CENTER OF THE DEVICE E 1 X RACEWAY /WIRE /CABLE x--.0•(1,3) UGHT FIXTURES & LAMPS HOME RUN WITH CIRCUIT NUMBER(S) CABUNG /RACEWAY - CEIUNG OR WALL - SEE SPECS. FOR APPL CONDUIT/RACEWAY REQ'TS. (FULLY CONCEALED IN FINISHED AREAS, CONCEALED TO OVERHEAD STRUCTURE IN UNFIN. AREAS) X ___ - -- X CABUNG /RACEWAY - BELOW FLOOR /GRADE - SEE SPECS. FOR APPL CONDUIT/RACEWAY REQ'TS. O SOUND SYSTEM JUNCTION BOX - ABOVE ACCESSIBLE CEILING OR AT STRUCTURE IN AREAS WITH NO CEIUNG X JUNCTION BOX - WALL (FLUSH IN FINISHED AREAS) D X ABBREVIATIONS AND NOTES EC. ELECTRICAL CONTRACTOR G.C. X GENERAL. CONTRACTOR AFF X ABOVE FINISHED FLOOR (OR GRADE /PAVEMENT WHERE APPUCABLE) TO CENTER OF OUTLET (UNLESS OTHERWISE NOTED) W/, PROVIDE WEATHERPROOF EQUIPMENT /FIXTURE /DEVICE 42' DISTANCE ABOVE FINISHED FLOOR (OR GRADE /PAVEMENT WHERE APPUC.) TO CENTER OF OUTLET CH COUNTER HEIGHT OR SPECIAL HEIGHT DEVICE COORDINATE WITH EQUIPMENT & ARCHITECTURAL ELEVATIONS GFI / GFCI GROUND FAULT CIRCUIT INTERRUPTER DEVICE (UNLESS SPECIFICALLY NOTED OTHERWISE ON DRAWINGS, DO NOT FEED DOWNSTREAM OUTLETS FROM LOAD SIDE TERMINALS OF GFI RECEPTS.) IG INDICATES ISOLATED GND. DEVICE W /PARTY SIZED ISOLATED /INSULATED EQT. GND. CONDUCTOR (GREEN W/YELLOW TRACER). PROVIDE DEDICATED #10 AWG NEUTRAL COND. FOR EA. PHASE COND. EWC ELECTRIC WATER COOLER UCR UNDER COUNTER REFRIGERATOR EWH ELECTRIC WATER HEATER FURNISHED & INSTALLED BY P.C., WIRED BY EC. IWH INSTANTANEOUS ELECTRIC WATER HEATER FURNISHED & INSTALLED BY P.C., WIRED BY E.C. NOTE: EQUIPMENT SHOWN FADED AND DASHED ARE EXISTING TO REMAIN. LANDLORD ELECTRIC ROOM-10- FLOOR 200AS /3P /200AF LANDLORD'S SWITCHBOARD 277/480V, 30, 4W -- AEROSOLES TENANT SPACE 1 0 - EXISTING 11 PANEL H L 1- --iLC1 1 1 120/208V 30,4W 225A BUS: 1200A MLO 0 42 POLE j TO TELEPHONE .,,o-- DISTRIBUTION T 30kVA LC2 FACP .� ELECTRICAL RISER DIAGRAM SCALE: NONE EXISTING TELEPHONE 1 EQUIPMENT BOARD TTB 18 "Wx4'Hx 1 3 /4 "TH FLOOR ® CODED NOTES 1. EXISTING 200AS /3P MAIN SWITCH SHALL REMAIN. PROVIDE NAME PLATE TO READ "AEROSOLES ". NAMEPLATE SHALL BE BLACK WITH 1" HIGH WHITE LETTERS. LABEL SHALL BE PERMANENTLY ATTACHED TO EQUIPMENT. 2. EXISTING ELECTRIC UTIUTY METER SHALL REMAIN. E.C. SHALL CONTACT UTIUTY COMPANY TO TRANSFER ELECTRIC SERVICE INTO OWNER'S NAME. PROVIDE NAME PLATE TO READ "AEROSOLES ". NAMEPLATE SHALL BE BLACK WITH 1" HIGH WHITE LETTERS. LABEL SHALL BE PERMANENTLY ATTACHED TO EQUIPMENT. 3. EXISTING 200 AMP WIRE AND CONDUIT SHALL REMAIN. 4. EXISTING 240 VOLT, 3 PHASE DISCONNECT SWITCH SHALL REMAIN. 5. EXISTING PANEL L SHALL REMAIN. REUSE BREAKERS WHEREVER POSSIBLE. REFER TO SCHEDULE ON THIS SHEET FOR MORE INFORMATION. 6. EXISTING 100 AMP WIRE AND CONDUIT SHALL REMAIN. 7. EXISTING 30kVA, 208V TO 480V, REVERSE FEED, FLOOR MOUNTED TRANSFORMER SHALL REMAIN. 8. EXISTING WIRE AND CONDUIT TO HVAC EQUIPMENT SHALL REMAIN. 9. PROVIDE LIGHTING CONTACTORS AND TIMECLOCK. SEE UGHTING SWITCH BANK AND NOTES ON LIGHTING PLAN FOR MORE INFORMATION. 10. EXISTING PLYWOOD TELEPHONE EQUIPMENT BOARD SHALL REMAIN, 11. EXISTING CONDUIT FOR TELEPHONE/DATA FROM LANDLORD'S DISTRIBUTION POINT TO EXISTING TELEPHONE BOARD LOCATION SHALL REMAIN. PROVIDE ALL TELEPHONE/DATA CABLING AS REQUIRED FOR TELEPHONE AND DATA SERVICES. NO EXPOSED TELEPHONE CABLES IN RETURN AIR PLENUMS. E.C. SHALL CONTACT THE LOCAL TELEPHONE COMPANY TO ARRANGE FOR TELEPHONE SERVICE IN OWNER'S NAME. COORDINATE EXACT REQUIREMENTS WITH CONSTRUCTION MANAGER AND LANDLORD. 12. PROVIDE ALL REQUIRED TELEPHONE AND DATA CABLING AS REQUIRED BY AEROSOLES. NO EXPOSED TELEPHONE CABLES IN RETURN AIR PLENUMS. COORDINATE EXACT REQUIREMENTS WITH AEROSOLES' PROJECT MANAGER. 13. EXISTING FIRE ALARM BATTERY CABINET SHALL REMAIN. GENERAL RISER NOTES A. PARALLEL FEEDER CONDUCTORS SHALL BE CUT TO EXACTLY THE SAME LENGTHS AND SHALL BE FROM THE SAME FACTORY RUN. ALL CONNECTIONS FOR SAME SHALL BE TORQUED TO IDENTICAL VALUES. B. EXTERIOR ELECTRICAL WORK SHALL NOT ONLY BE WEATHERPROOF AND WATER - TIGHT, BUT SHALL ALSO BE RUST - RESISTANT. C. CONDUCTORS BELOW GRADE OR SUBJECT TO MOISTURE SHALL BE "XHHW -2 ". D. PROVIDE FACTORY SERIES COORDINATION FOR ALL CIRCUIT BREAKERS (INCLUDING ALL BRANCH BREAKERS), RELATIVE TO "UPSTREAM" BREAKERS, SO THAT ONLY THE BREAKER CLOSEST IN THE CIRCUIT TO THE LOAD TRIPS UPON AN OVERLOAD OR FAULT CONDITION. E. POWER DISTRIBUTION EQUIPMENT SUPPUER SHALL PROVIDE EQUIPMENT APPROPRIATELY RATED AND BRACED TO ACCOMMODATE THE AVAILABLE FAULT CURRENT AT THE UTIUTY COMPANY TRANSFORMER SECONDARIES. THIS SUPPUER SHALL ACCORDINGLY PROVIDE ANY RELATED CALCULATIONS SO THAT THEIR EQUIPMENT IS PROPERLY COORDINATED FOR THE AVAILABLE FAULT CURRENT. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THIS SUPPUER WITH COPIES OF THE ELECTRICAL DOCUMENTS AS REQUIRED SO THAT PROPERLY RATED/BRACED EQUIPMENT IS PROVIDED UNDER BASE BID. F. GROUNDING ELECTRODE WITH N.E.C., INCLUDING CONDUCTORS MAY NOT PROVIDED UNDER BASE G. EQUIPMENT GROUNDING WITH N.E.C., INCLUDING CONDUCTORS MAY NOT PROVIDED UNDER BASE CONDUCTORS SHALL BE PROVIDED IN STRICT COMPUANCE N.E.C. ARTICLE 250 AND TABLE 250 -66. THESE BE INDICATED ON RISERS OR SINGLE -UNES, BUT SHALL BE BID NEVERTHELESS. CONDUCTORS SHALL BE PROVIDED IN STRICT COMPUANCE N.E.C. ARTICLE 250 AND TABLE 250 -122. THESE BE INDICATED ON RISERS OR SINGLE -UNES, BUT SHALL BE BID NEVERTHELESS. H. WORKING CLEARANCES SHALL BE PROVIDED FOR ALL ELECTRICAL EQUIPMENT (SWITCHBOARDS, PANELBOARDS, TRANSFORMERS, STARTERS, DISCONNECTS, ETC. AS APPLICABLE) IN STRICT COMPUANCE WITH N.E.C. CHAPTER 1, PART B, SECTION 110- 26(a). LOCATIONS SHOWN ON FLOOR PLANS ARE SCHEMATIC AND DIAGRAMMATIC IN NATURE. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING COMPUANCE WITH THE ABOVE N.E.C. REFERENCE. THIS REQUIREMENT APPUES TO EQUIPMENT ON FLOOR PLANS AS WELL AS TO EQUIPMENT SHOWN ON RISER. I. HOLD ALL NEW OVERHEAD ELECTRICAL WORK AS TIGHT AS POSSIBLE TO THE BOTTOM OF THE OVERHEAD STRUCTURE. LOCATE ANY RELATED PULLBOXES SO THAT THEY WILL BE FULLY ACCESSIBLE AFTER ALL CONSTRUCTION WORK IS COMPLETE. AS WITH ALL WORK, COORDINATE IN ADVANCE WITH ALL OTHER TRADES. J. ROUTE FEEDER CONDUITS BELOW GRADE WHEREVER POSSIBLE. VERY UMITED SPACE EXISTS ABOVE ACOUSTICAL TILE CEIUNGS AND MANY, IF NOT MOST, OF THE SPACE ABOVE THE GYPSUM BOARD CEILINGS IS NOT AVAILABLE FOR RUNNING CONDUIT. STUDY ALL ARCHITECTURAL, STRUCTURAL & MECHANICAL DRAWINGS VERY CAREFULLY BEFORE LAYING OUT FEEDER ROUTES. K. ALL PANELS HAVE NEMA 1 ENCLOSURES UNLESS NOTED OTHERWISE. L. ALL PANELS ARE SURFACE MOUNTED UNLESS NOTED OTHERWISE. N. E.C. SHALL FIELD VERIFY EXISTING CONDITIONS, EQUIPMENT SIZES AND LOCATIONS, AND FEEDER SIZES PRIOR TO BEGINNING WORK AND REPORT ANY DISCREPANCIES FOUND. ELECTRICAL RESPONSIBILITY SCHEDULE ITEM LANDLORD G.C. OWNER SITE COND. REMARKS FURN INST FURN INST FURN INST EXIST NEW TEMPORARY POWER X MAIN OVERCURRENT DEVICE IN LANDLORD'S ELECTRIC ROOM X REFER TO RISER DIAGRAM SERVICE ENTRANCE CONDUIT TO LEASE SPACE X REFER TO RISER DIAGRAM SERVICE ENTRANCE FEEDERS TO LEASE SPACE X REFER TO RISER DIAGRAM ELECTRICAL PANELS X REFER TO RISER DIAGRAM METER REQUIREMENTS X REFER TO RISER DIAGRAM TENANT ELECTRICAL TRANSFORMERS X REFER TO RISER DIAGRAM TIMECLOCK & CONTACTORS X X X ELECTRICAL SERVICE FOR HVAC MOTORS/EPT. X HVAC CONTROLS X TELEPHONE CONDUIT STUB UP X TELEPHONE EQUIPMENT & CABUNG X GENERAL CONDUIT & WIRING X X _ X X RECEPTACLES AND SWITCHES X X X X SEE POWER PLAN (SHEET E -2) UGHT FIXTURES & LAMPS X X X X SEE UGHTING PLAN (SHEET E -1) SOUND SYSTEM X X X PROVIDE ROUGH -IN ONLY FIRE ALARM SYSTEM X X X X MODIFY OR ADD TO EXISTING SYSTEM AS REQUIRED. PANEL NAME L (EXISTING) VOLTAGE 208 PHASE 3 WIRE 4 LOCATION STOCK ROOM SOURCE LANDLORD DISTRIBUTION THROUGH ADJACENT DISCONNECT SEE RISER - PROVIDE NEW ISOLATED GROUND BAR # L R M 3 0.1 0.1 5 0.4 9 0.2 11 0.2 21 0.5 23 25 1.1 0.5 29 0.7 HIC BREAKER AMP POLE DESCRIPTION agWd LIGHTS - RESTROOM f KVA /PHASE A B C RECEPT - STOREFRONT 0.8 SE 0.8 to TIMECLOCK CONTACTORS 0.5 DESCRIPTION BREAKER AMP POLE R M H C MANAGER'S DESK LIGHTS - TRACK 0.6 0.4 2 4 LIGHTS - TRACK 0.5 6 LIGHTS - PENDANT 0.1 8 0.5 RECEPT - CASHWRAP IG RECEPT - CASHWRAP RECEPT - SALES RECEPT - SALES SUBFED TCL FROM Maatim vv SOW TOTAL CONNECTED LOAD /PH LIGHTS - SALES STOREFRONT DOWNLIGHTS STOREFRONT TRACK RECEPT - MUSIC SYSTEM SPARE SPARE VIN: OA 0.3 0.3 • 1.3 ............. 2.2, 3.7 Ci ......., 0.0 0.0 3.5 0.5 8.8 9.5 11.5 0.00 TOTAL CONNECTED LOAD 29.83 SPARE • teittet 0.5 10 12 14 16 20 22 38 L = LITE R = RCPT M = MISC H = HEAT C = COOL DEMAND 125% FIRST IOKVA AT 100% AND REMAINING AT 50% DEMAND 100% DEMAND 100% IF H >C, 0% IF H <C DEMAND 100% IF C >H, 0% IF C <H 5.1 KVA 3.6 KVA 7.9 KVA 14.3 KVA 0.0 KVA TOTAL CONNECTED LOAD: GROWTH FACTOR: TRANSFORMER KVA LOAD: TOTAL PANEL DEMAND = (FACTOR) X 29.8 KVA 1.00 29.8 KVA 30.8 KVA 1.00 30.8 KVA 85.7 AMPS SECURITY SYSTEM 20 S = PROVIDE SWITCHING DUTY RATED BREAKER. L = PROVIDE A HANDLE LOCK -OFF BREAKER G = PROVIDE A GFI BREAKER. T = INDICATES C/B CONTROLLED BY TIMECLOCK EX = EXISTING CIRCUIT TO REMAIN CT = COMMON TRIP BREAKERS 40 0.5 42 COMMENTS 1. PROVIDE (2) #12,(1) #12GND,3 /4 "C FOR ALL BRANCH CCTS UNLESS STATED OTHERWISE. 2. PROVIDE HACR RATED BREAKERS ON ALL MOTOR LOADS. 3. PROVIDE LOCKING TYPE BREAKER FOR ALL LIFE SAFETY AND NIGHT LIGHTING BRANCH CIRCUITS. ._:.:. CTORMA REVIEWED FOR d PLIANCE WITH . NFPA 70 - NEC AUG 08 2012 o Tukwila BUILDING DIVISION CITY OF TUKV►IiA JUL 3 0 2012 PERMIT CENTER W% SET- 1-19 -12 SEAL: AEROSOLES '2 2Q1w J ,1111 7" 91197 00 Q Y o)) W Zd.�Z O N =c o W Z I- D W Z I U V I� a. I c I- W�OJ 1,.1L'-ZV)1'- I"' < 1'- W w M W Lin S I- (0 V) SHEET TITLE: ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULES REVISIONS: NO: DATE: BY: PROJECT NO: DRAWN BY: 12874.00 SCHMID, SOSA SHEET OF 3 1. GENERAL REQUIREMENTS Requirements apply The General Provisions of the Contract including any General and Supplemental Conditions and Gen e ral q uirements pp y to the work in this section. Before submitting a bid, examine all Mechanical, Architectural, and /or Structural documents, visit the site and get acquainted with all conditions that may in any way whatsoever affect the execution of this contract. Take measurements and be responsible for exact size and locations of all openings required for the installation of work. Figured dimensions are reasonably accurate and should govern in setting out work. Where detailed method of installation is not indicated or where variations exist between described work and approved practice, direction of the Owner's representative on job site shall be followed. The contract includes all items of material and labor required for the complete installation and full operation of the electrical work as shown on the drawings and hereinafter specified. All work, materials, and equipment shall have a one year warranty after acceptance of the work by the Owner. Any defective items shall be removed and replaced at the electrical sub - contractor's expense and to the satisfaction of the Engineer. Perform work under this contract in close harmony with other contractors so completed work shall present a neat and workmanlike installation. Exposed finished materials and equipment shall be carefully cleaned and wiped to remove grease, smudges, dust and other spots and left smooth and clean. During the progress of the work, the electrical sub - contractor shall carefully clean up after his men and shall leave the premises and all portions of the building in which he is working free of debris and in a clean and safe condition. Tighten electrical connectors and terminals, including screws and bolts, in accordance with equipment manufacturer's published torque tightening values for equipment connectors. Where manufacturer's torquing requirements are not indicated, tighten connectors and terminals to comply with tightening torques specified in applicable UL and NEC Standards. Whenever the words "contractor", "this contractor, etc. appear on drawings or in these specifications for the Electrical Work, it shall refer to the Electrical Sub - Contractor. Whenever the word "provide" appears in these documents, it shall be interpreted to mean "Furnish & Install ". Outlet mounting heights as indicated on the plans are approximate to be used for bidding purposes only. The exact mounting height of outlets shall be determined in the field with relation to architectural details and equipment being served. It shall be the responsibility of this contractor to coordinate outlet location with equipment. The Owner's representative shall be permitted to relocate any outlet prior to installation within a 15 foot limit at no additional charge in contract price. All fasteners, hangers and methods of hanging exposed work in finished areas shall be submitted to the Owner's representative for approval before installation. If during construction if becomes apparent that certain minor changes in layout will effect a neater job or better arrangerrrent, such alterations shall be made as part of the contract. Engineer's approval shall be obtained before r making such changes. Workmanship throughout shall conform to the standards of best practice. Marks, dents or finish scratches will not be permitted on any exposed materials, fixtures or fittings. Inside of panels & equipment boxes shall be left clean. t The system shall ring entirely free from ground when tested out in the presence of the Owner's representative. This contractor shall be responsible for the proper instruction of each system to the satisfaction of the Owner's representative. Upon completion of the job, this contractor shall furnish the Owner with a complete set of operating instructions on all electrical systems installed. The Electrical al Contractor or shall co nsult the plans o f II other trades in all instances before installing his work so that his piping will not interfere with those branches. In the event of a conflict, this contractor shall report to the Owner's representative at once arid further work to be installed do no u until a satisfactory arrangement is decided upon. Any work done, or equipment placed in position by this contractor, creating a conflict in violation hereof, shall be readjusted to the satisfaction of the Owner's representative at the expense of the contractor. The decision of the Owner's representative shall be final in regard to changes due to conflicting conditions. TEMPORARY ELECTRIC SERVICE Unless directed otherwise, the general contractor will pay for all current for all trades during construction. The electrical contractor shall provide and maintain all power lines (including circuit protection, physical protection, grounding, etc.) to the temporary offices of all trades requiring same, extending from the temporary electrical service. Where applicable, provide temporary security site lighting as required and /or as directed in field. Make all necessary arrangements with local utility companies for temporary electrical service and pay all associated fees for inspections, connections, initiation, etc. Power may be derived from the existing building electrical systems. Coordinate carefully in advance with the owner and do not permit any electric welders to be used from any building service. Electrical contractor shall furnish all temporary light (including lamps) and power complete with all wiring and similar equipment as required, for all work on the site and within the affected buildings during the construction period. Feeders shall be properly fused and ground fault protected per N.E.C. and per all authorities having jurisdiction. Feeders and lamps shall be physically protected along their entire length. Temporary branch circuit wiring shall be installed per NEC in each area with outlets on minimum ten foot centers to accommodate lamps and with receptacles on nominal fifty foot centers to accommodate extension cords provided by the contractor in need of them. The electrical contractor shall furnish and maintain all lamps required for the duration of the job. Sufficient sockets and circuit capacity shall be provided for all construction areas. A minimum of 10 foot candles of illumination shall be maintained in all spaces or as required by OSHA. Provide all necessary specialty temporary power and /or supplementary light for all trades requiring same. At the conclusion of the project, all temporary electric service materials shall be removed by the electrical contractor and become the property of same. 2. SHOP DRAWINGS The contractor shall submit shop drawings on all items of material and equipment for approval by the Engineer. The contractor is not authorized to purchase any material until such approval is obtained. A minimum of six separate sets of drawings is required and will be distributed as follows: 1 copy for Engineer's file; 1 copy for Architect's file; 2 copies for the Owner's file; 2 copies for the contractor. Shop drawings shall be neatly bound in a flat ring binder having job name and contractors name on cover. A single submission is preferred having all items included. Loose sheet or incomplete submittals will not be accepted. All items of material to be supplied which do not require shop drawing submission such as conduit, wire, boxes, etc., shall be listed as separate material showing manufacturer's name and catalog number and type and shall be included with shop drawings submittal. 3. RECORD DRAWINGS AND OPERATING INSTRUCTIONS & SERVICE MANUAL Two sets of mechanical /electrical drawings shall be provided as record drawings which shall be separate, clean, sepia reproducibles reserved for the purpose of showing a complete picture of the work as actually installed. These drawings shall also serve as work progress report sheets and the electrical sub - contractor shall make any notations, neat and legible thereon daily as work proceeds. The drawings shall be available for inspection at all times and shall be kept at the job at a location designated by the Owner's representative. At the completion of the work, these record drawings shall be signed by the electrical sub - contractor, dated and returned to the Owner's representative. Final payment of contract will not be made until receipt and review of said drawings. Provide two neatly bound (with tabbed sections) copies of maintenance and instruction books, parts list pertaining to all equipment furnished. Submit to the Owner's representative for approval. Final payment will not be made until drawings for record, maintenance and instruction manuals are delivered to the Owner's representative. 4. PERMITS AND REGULATIONS The latest edition of the National Electric Code shall be the minimum requirement for all work. All electrical materials used in this work and all workmanship and tests performed therein, unless specifically specified shall conform to the latest rules and regulations and specifications of the National Board of Fire Underwriters, local and state codes and authorities having jurisdiction and utility company. Examine the drawings and specifications for compliance with prevailing codes, regulations and ordinances and base bid and work accordingly. Any minor discrepancy between these drawings /specifications and codes, laws, ordinances, rules and regulations shall be corrected by this contractor as required without any additional reimbursement. Major discrepancies shall immediately be brought to the attention of the engineer (in writing), prior to installation, along with the contractors proposed cost for correction. This contractor shall obtain and pay for all permits or certificates of inspection and approval required for this branch of the work. Owner shall be furnished with certificates of final inspection and approval prior to final acceptance of this branch of the work. 5. DRAWINGS AND SPECIFICATIONS The specifications and accompanying drawings are intended to describe the scope of all electric /mechanical work. The drawings are an outline to indicate the approximate location and arrangement of raceways, wiring and equipment. The drawings shall be followed as closely as possible in executing of the work. Should there be a conflict between drawings and specifications, this contractor shall refer the matter to the Owner's representative for a decision as to method or material. Electrical Contractor shall refer to drawings of all other trades for details, dimensions and locations of other work and route his work so as not to conflict with any other branch. This contractor shall be responsible for checking quantities of equipment mentioned in the specifications with those shown on the drawings. If discrepancies are noted, provide the greater of the quantities or the better of the qualities as applicable. 6. MATERIALS AND EQUIPMENT All materials and equipment shall be new. All materials, apparatus and equipment shall bear the Underwriter's Laboratories Inc., label where regularly supplied. Certain manufacturers of material and equipment are specified and plans are detailed according to this material. This contractor shall base his bid on furnishing and installing this make of material and equipment. Where more than one make of material or equipment is specified, the contractor shall state in his bid which make he proposes to furnish. 7. ELECTRICAL IDENTIFICATION Provide manufacturer's standard self- adhesive vinyl tape not less than 3 mils thick by 1 -1/2" wide. Where applicable, install on all concealed raceways at connection to all junction boxes, pull boxes, equipment, wall /floor /, etc. Unless otherwise indicated or required by governing regulations, provide orange tape with black letters. Provide circuit identification bands for all cables and conductors. Provide manufacturer's standard color coding for cable /conductor jacket and /or insulation for all cables and conductors of all systems. Match identification with marking system used in existing systems (where applicable), shop drawings, contract documents, and similar previously established identification for project's electrical work. Provide on all conductors of all systems. Install engraved plastic - laminate sign on major units of electrical equipment, including central or master unit of each electrical system including communication /control /signal systems, unless unit is specified with its own self - explanatory identification or signal system. Except as otherwise indicated, provide single line of text, 1/2" high lettering, on 1 -1/2" high sign (2" high where 2 lines are required), white lettering in black field. Unless determined otherwise in field, provide text matching terminology and numbering of the contract documents and shop drawings. Secure to substrate with fasteners, except use adhesive where fasteners should not or cannot penetrate substrate. As a minimum provide signs for each unit of the following categories of electrical work where such work exists on the project all starters and disconnects; All remote fixture or equipment switching devices (via engraved wallplates); All System devices, ports, taps, J.B.'s, P.B.s, etc.; Panelboards, electrical cabinets ; Any other equipment designated by Owner or engineer in field. All equipment & system identification nomenclature shown on drawings or listed herein is shown for general design and installation reference only. The actual nameplate, etc. nomenclature for this project shall be verified by electrical contractor in field prior to fabrication and where applicable, shall be an extension of existing nomenclature used on the site as determined in field by electrical contractor. In addition to the above, all labeling for all electrical wiring work (for all systems) shall be 3M DCI No. 054007 -11954 "SWD" Write -on Tape Dispenser Kit with factory provided special fast drying marker included with kit. All markings shall be clear and legible. As determined in field, provide color coding for junction boxes, pull boxes and associated plates to match existing building standards. The following insulation color code shall be used for system and voltage identification for feeder and branc h circuit wiring. 277/480V System - Brown, Orange, Yellow & Gray (neutral 120/208V System - Black, Red, Blue & White (neutral) Equipment Grounding - Green Systems - To match existing, verify in field. 8. GROUNDING All metallic conduit, surface wireways, supports, cabinet and equipment shall be grounded in accordance with the latest issue of the National Electrical Code and shown on plans. The ground terminals of receptacles shall be connected to the equipment ground bus of the source branch circuit panelboard. All grounding conductors shall be protected from mechanical injury. All connections to equipment or conduit shall be make with an approved conductor and same shall be bolted or clamped to equipment and conduit. All contact surfaces shall be thoroughly cleaned and bright before connections to insure a good metal contact. All new branch circuiting installed under this contract shall be provided with redundant insulated parity sized green ground wire by this contractor, installed in strict accordance with NEC Article 517. This contractor shall field test all exposed conductive surfaces in all new "Patient Vicinity' areas, and provide all necessary corrective work (if any) to comply with grounding requirements of NEC Article 517. Provide documentation of all testing results to engineer and state electrical inspector. 9. CONDUIT AND FITTINGS All wiring for different power voltages shall be installed in raceway systems separate from each other (i.e. 24V separate from 120/208V). Only voice and data cables may share raceways. All wiring run in finished spaces shall be run in Wiremold surface steel raceway. All conduit installed indoors shall be galvanized steel EMT (3/4" minimum); all fittings for same shall be set screw type steel, with insulated throats. All wiring of all systems shall be installed in conduit unless specifically indicated otherwise herein or on drawings. Conduit runs exceeding 100 feet in length or having in excess of three 90 degree turns shall be provided with pull boxes. Conduit fill shall not exceed 30 percent. All conduit systems (including J.B.'s, P.B.'s, etc.) shall be permanently identified. New branch circuit home -run conduits shall be no larger than 1 -1/4" diameter. Conduit fill shall not exceed NEC requirements. Conduit shall be cleaned inside before any wires are pulled. Conduit ends shall be capped and plugged with standard accessories as soon as conduit has been permanently installed. Conduit installed without conductors shall be provided with sweep bends and baling wire for pulling. joints shall be made tight with watertight couplings matchin conduit and all corners shall be make with long radius. The ends of all conduits All s s g g matching shall be cut square and reamed and all joints brought to a shoulder. Conduit shall be continuous between outlets to make a complete installation and to effect a continuous ground. Suitable supports and fastening shall be provided for conduit. Conduit shall be supported by approved straps, fasteners and hangers. Hangers shall be suspended from rods. Perforated straps will not be acceptable. Fasteners shall be lead expansion shields in block or concrete, toggle bolts in hollow walls, machine screws on metal surfaces and wood screws on wood construction. All conduit shall be supported independently from all other building systems and shall be supported directly from structural components. Provide sleeves for all fire wall and smoke partition penetrations (sealed accordingly). All raceways shall be entirely free of plaster, mortar, water and other foreign matter. Raceways installed under this contract without conductors shall have baling wire left in raceways from outlet to outlet for future pulling of conductors. Raceways open ends shall be plugged or capped in an approved manner. Where "fishing" through existing hollow partitions is mandatory, use. minimum 3/4" "Greenfield" (steel) for low voltage cabling and metal - clad /armored cable (listed for use in health care facilities) for power. Otherwise type MC /AC cable may only be used for 6' fixture whips, unless case -by -case permission is granted by engineer and owner. 10. METHOD OF WIRING - POWER Neatly dress all work. Install all work parallel and perpendicular to surfaces or exposed structural members, and follow surface contours, where possible. sible. Kee P condu ctor splices to minimum. Install splice and t a P connectors which possess equivalent uivalent or better mechanical chanical strength th and insulation rating than conductors being spliced. Use splice and tap connectors which are compatible with conductor material. All wires shall be run continuous from outlet to outlet/fixture to fixture. Insulation value of joints to be 100% in excess of wire. Provide adequate length of conductors within electrical enclosures and train the conductors to terminal points with no excess. Bundle multiple conductors, with conductors larger than no 10 AWG cabled in individual circuits. Make terminations so there is no bare conductor at the terminal. Branch subfeeder circuits shall be installed as shown on the floor plans. Where outlets are indicated by letters on plans, they shall be controlled by corresponding switches. No wire size smaller than No. 12 shall be used for any branch circuit unless otherwise noted on plans for control circuits. Larger sizes shall be used where required and /or indicated on the plans. Distances from panel to first outlet of a 15 or 20 ampere branch circuit shall require the following minimum wire size to the first outlet. Up to 100 feet: #12 100 TO 200 FEET: #10 More than 200 feet: # 8 All branch circuits more than 200 feet in length shall be minimum No. 10 to the last outlet. Control circuits shall be No. 14 except for runs exceeding 300 feet where they shall be No. 12. Outlets shall be located approximately as shown on the plans and shall be wired to provide control of outlets indicated. All wires of any one circuit shall be run in the same conduit. All wires shall be run continuous from outlet to outlet. Insulation value of joints to be 100% in excess of wire. Mechanical wire splicers shall be Scotchlock insulated type, T &B Stakon or approved equal. The conductors terminating at each wired outlet shall be left not less than 8" long at their outlet fittings to facilitate installment of devices of fixtures. Friction and rubber tape conform to Federal Specifications HH -T -11 and HH -T -111. Plastic electrical tape shall be Scotch #33+ or approved equal. Type MC Cable shall be formed from continuous length of spirally wound, interlocked zinc - coated or galvanized (inside & outside) strip steel. All conductors shall be rated for 90 deg. C. minimum. Provide with full parity sized green insulated equipment ground conductor. Provide compatible steel fittings with integral red plastic insulated throat bushings, compliant with NEC 350 -5. Cables shall be 90 deg. C. rated with all components and fittings listed for grounding and compliant with the following. a) UL Std.4 and UL Std. 83. b) ANSI E119 and E814. c) NEC Articles 250 and 333. Type MC cable may be utilized only if NEC approved and if approved by local authority having jurisdiction and if included in the limited applications defined below. 1) All new 15 or 20 ampere branch circuit work. This shall apply only under all of the following circumstances and conditions. a) Only where concealed (all exposed wiring shall be installed in conduit). b) Route all cables perpendicular and parallel to the building architectural lines /surfaces /structural members, keeping offsets to a minimum and following surface contours where possible. Maintain a uniform elevation for all cable runs wherever possible. All cables shall be supported /anchored at maximum 4 foot intervals and within 12" of box or outlet and shall not sag. Install cables in a manner that prevents overheating. Cables shall be fastened directly to the structure using factory clamps /clips specifically designed for the respective cable (Caddy or equal). ALL EXPOSED MC CABLE SHALL BE FIELD PAINTED BLACK. 11. COMMUNICATION TECHNOLOGY SYSTEMS GENERAL Voice and data cables shall be installed in "J- Hook" style pathway where indicated on drawings. All other wiring /cables of voice /data systems and all other systems shall be installed in conduit, 1" minimum. Verify route for "J- Hook" work above ceiling in field in advance with owner. Provide outlet boxes and conduit stubs for systems as indicated on drawings. Conduit stubs shall be turned out in joist space and, where located in areas with drywall ceilings, shall be extended to the nearest area with no ceiling or with acoustical tile ceiling. Provide conduit, bridle rings and raceways as required. All conduits shall be provided with sweep "L" 90's and insulated throat fittings (or bushings). Typical outlets shall consist of a flush wall mounted 4" square X 2 -1/8" deep box with a double gang plaster ring. Maximum conduit fill for new work shall be 40 %, based on manufacture's published data of cable outside diameter. Cable, terminations, jacks, labeling, hardware, shall be provided by a certified Communication Technology Contractor. Cabling system shall be provided as required for a turnkey, complete working systems. Determine exact locations of communication technology equipment, equipment outlets, etc. in field. Use caution not to exceed the allowed bending radius for respective cables and not to compromise the integrity of the cables during installation by pulling tie -wraps too tightly, damaging cables, etc. Raceway /Cabling bending radii shall be minimum as directed by cable manufacturer. Use pulling compound or lubricant, where necessary; compound must not deteriorate conductor or insulation. Neatly dress all cable work. Work shall be installed in a manner which results in maintaining a minimum distance of 24 inches from feeder /branch circuit raceways and from any ballasted lighting fixture. Provide color coded jackets to identify runs of different systems. Neatly route cables parallel and perpendicular to building architectural lines. Group cables by system type wherever possible. Verify exact locations of telephone switch, data server(s), head -end equipment, equipment outlets, etc. in field. Review all termination and labeling requirements with Owner in advance. All cable shall be provided with permanent adhesive labeling identification by this contractor. Provide transparent adhesive coverings over each label, wrapped around the labels at least two times. The long axis of the labels shall installed be parallel to the long axis of the respective cable assemblies. Labels shall be approximately 1 -1/2" long by 3/8" high. Install power cables in a manner which prevents over - heating. Otherwise, wherever possible, bundle cables of the same system together. Also provide color coded jackets, or other approved labelling /identification method, to identify runs of different systems. All cables which are not routed in conduit shall be neatly bundled, secured at four foot intervals and identified at ten foot intervals. Wherever possible, bundle cables of the same system together. Conduit sizes (and systems furniture whips where applicable) shall be provided as follows. Provide additional wall outlet boxes and additional whips as /if required at systems furniture to achieve same. Conduit Diameter Application (1) 3/4" All Wall Phones (1) 1" All Wall Tech. Outlets at Individual Desks or tables (1) 1" All Wall Tech. Outlets at Individual Work Stations, PC's, Copiers, Faxes, etc. Ceiling cavities will not be used as environmental air plenums. "J- Hook" Pathways Cable distribution bridle rings shall be equal to Caddy #4BRT64 or Mono - Systems Inc. The Hook" (minimum 4" diameter or 4" square usable internal area) constructed of aluminum or corrosion resistant steel with rolled edges or equivalent to prevent damage to cable jackets and insulation. Provide splits or openings so that cables can be laid in the rings rather than threaded through. Provide maximum 30% fill (in cross section), based on outside diameter of cables. Accordingly, provide multiple sets of rings along any routes as /if required. Provide rings at four foot intervals and at all offsets. Route rings through corridors and similar open areas wherever possible to minimize wall penetrations. Securely anchor (mechanical - not adhesive) all rings directly to structural components of the building. Rings shall not be anchored to ductwork, conduit, piping, fixtures, equipment, ceiling supports, etc. All rings shall be fully and readily accessible after installation. Neatly route bridle ring paths parallel and perpendicular to building architectural lines and at a consistent elevation wherever possible. Route all bridle ring paths and cables perpendicular and parallel to the building architectural lines, keeping offsets to a minimum. Install bridle rings in a uniform plane /elevation wherever possible, keeping vertical offsets to an absolute minimum. Prior to installation, submit scaled coordination drawings showing all proposed routing and ring locations for review by Owner. Keep offsets to an absolute minimum. Bridle ring paths shall be routed so that a minimum of 24" exists between any cables and any EMI source such as ballasts, motors, power wiring, etc. 12. OUTLET, JUNCTION AND SWITCHBOXES Gang type outlet boxes shall not be used. The outlet box locations indicated on drawings shall be considered approximate, and therefore, it shall be incumbent upon this contractor to study the general construction with relation to spaces and equipment surrounding each outlet. All outlet, switch and junction boxes shall be made of code galvanized steel complete with rings and screw cover plates and located where shown and noted on drawings. Where conduit is concealed, boxes shall not be less than 4" square x 1 -1/2" deep. All boxes shall be equipped with proper covers to bring flush with finished wall surface. Where outlet boxes occur in block, cinder, or concrete block, facing tile or other material where such materials form the finished wall surface, the opening for the box shall be cut neatly and of the size that the cover plate will cover all parts of the opening. Condulets shall be used on exposed raceways. In general, junction boxes shall be furnished and required by the National Electric Code, of the proper sizes, and shall be constructed of #12 gauge steel with removable front fastened on with counter sunk head screws or other approved means. For special application, junction boxes shall be noted, detailed and /or sized on the drawings or in the field as required. 13. HEIGHT OF BOXES Prior to rough -in, verify all box /device mounting heights and locations in field with Owner's representative relative to equipment being served and relative to existing conditions where applicable. In general, where not located at counter areas, the height of boxes from finished floor to center of boxes shall be as follows, unless otherwise noted on plans: Switches Receptacles Telephone Outlets (desk phone) Telephone Outlets (Wall phone) Data Cable Outlets Fire Alarm manual pull stations Fire Alarm AN alarms 14. WIRE AND CABLE 4'0" 1'6" 1'6" 4'0" 1'6" 4'0" 6'8" (verify) Furnish and install all necessary cable of the size and type indicated on the drawings or specified hereinafter. All wire shall be copper. All wiring shall be new. No wire smaller than #12 AWG shall be installed unless specifically designated. Use of #14 color coded wire will be allowed for control circuits only. All wiring shall be in conduit unless specifically indicated otherwise herein. All conductors shall be copper. Provide stranded conductors for all sizes unless indicated otherwise. Provide THHN/THWN insulation for all conductors size 500 MCM (kcmil) and larger, and no. 8 AWG and smaller. For all other sizes provide THW or THHN /THWN insulation as appropriate for the locations where installed. Provide color coded insulation /jacket for phase identification. All wires shall be rated at 600 volts. Provide type XHHW -2 insulation for all wiring subject to moisture, for all wiring below grade and for all wiring fed from isolated power systems. Keep conductor splices to minimum. Pull conductors simultaneously where more than one is being installed in same raceway. Use UL listed pulling compound or lubricant, where necessary. Install splice and tap connectors which possess equivalent or better mechanical strength and insulation rating than conductors being spliced. Use splice and tap connectors which are compatible with conductor material. Increase wire sizes per NEC to offset voltage drop as /if required. 15. WIRING DEVICES DEVICE COLORS: REFER TO LIGHTING AND POWER PLANS FOR SPECIFIC DEVICE COLOR REQUIREMENTS. SPECIFICATION GRADE RECEPTACLES: Duplex receptacles shall be equal to Leviton #5362 series (NEMA 5 -20R). Ground fault circuit interrupter duplex receptacles shall be equal to Leviton #8899 series (NEMA 5 -20R). Duplex isolated ground receptacles shall be equal to Leviton #5362 -IG. SWITCHES: Occupancy sensor lighting switches shall be manufactured by Watt Stopper and Greengate - REFER TO LIGHTING PLAN. WALL PLATES: Provide wall plates with engraved legends where indicated on drawings and /or where required per ELECTRICAL IDENTIFICATION Section. All device wallplates shall be standard size; "midway ", "oversized" ( "jumbo ") or "extra deep" wallplates shall not be acceptable. Construct with metal screws for securing plates to devices; screw heads colored to match finish of plates. 16. SUPPORTS, INSERTS, CUTTING AND PATCHING This contractor shall do all cutting and patching required for the admission of his work. Any damage done by this contractor to the building during the progress of his work shall be made good at his own expense. All patching shall be done by a skilled craftsman in that respective trade. It shall be the responsibility of this contractor to supervise the installation of, and pay for all additional members, wood or metal and labor which may be required to support any type of permanent or temporary electrical apparatus employed in the execution of this contractor's work. SEAL ALL NEW FLOOR, CEILING, WALL, SLAB, ETC. PENETRATIONS TO MATCH OR EXCEED EXISTING /NEW ASSEMBLY FIRE RATINGS. PROVIDE SLEEVE SEALS FOR ALL SLEEVES; PROVIDE SLEEVES FOR ALL PENETRATIONS. VERIFY REQUIREMENTS IN FIELD. ALL PENETRATIONS OF FIRE -RATED OR SMOKE -RATED WALLS, FLOORS, CEILINGS, ETC. SHALL BE SEALED IMMEDIATELY AFTER RACEWAYS ARE INSTALLED. ALL NEW ELECTRICALLY RELATED WORK SHALL BE SUPPORTED DIRECTLY FROM BUILDING STRUCTURAL MEMBERS. NEW ELECTRICALLY RELATED WORK SHALL NOT BE SUPPORTED FROM DUCTWORK, DUCTWORK HANGERS, CEILING SUPPORTS, EXISTING CONDUIT SUPPORTS, ETC. ALL CONDUITS (AND CABLE ASSEMBLIES, WHERE APPLICABLE) SHALL BE ROUTED PARALLEL TO BUILDING STRUCTURAL MEMBERS. ANY AND ALL NONCOMPLYING WORK INSTALLED BY THE ELECTRICAL CONTRACTOR SHALL BE REMOVED AND REINSTALLED TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE AND THE ENGINEER, AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. 17. LIGHTING FIXTURES All surface mounted ballasted fixtures shall be mounted with air spaces between fixture and surface per latest edition of NFPA/NEC. All recessed fixtures shall be equipped with necessary plaster frames and surface trim. All recessed fluorescent fixtures shall be equipped and suitably constructed to operate with "P" rated ballasts. All recess mounted incandescent and H.I.D. fixtures shall have UL approved thermal protection per latest edition of NFPA/NEC. All junction boxes and serviceable components (ballasts, thermal protection devices, fuses, etc.) for recessed fixtures shall be readily accessible for service or replacement from below the ceiling, without removing any ceiling components (other than tiles). Where plaster frames are inferred for lighting fixtures (either by narrative or by catalog number or by application) the actual function shall be taken to mean for mounting within gypsum board or similar type ceiling system (i.e. not within wet plaster ceiling system). All lighting fixtures utilized for emergency egress lighting shall be connected ahead of switching. All ballasts of the same type shall be of the same manufacturer and catalog number. All lamps of the same type shall be of the same manufacturer and catalog number. Provide low energy solid state rapid start electronic fluorescent lamp ballasts (less than or equal to 20% THD) specifically designed for operating lamp types indicated. Fluorescent ballasts shall be Motorola or Advance equal. All fixtures shown on drawings with multi -level switching shall be provided with multiple ballasts to accommodate same. All other fixtures may contain either single ballasts or multiple ballasts as required to fulfill required function and as required to comply with construction schedule. Incandescent lamps shall be Sylvania or Philips, long life type (3000 hours). All incandescent lamps shall be inside frosted unless specifically directed otherwise. Provide socket adapters /extenders if required for accommodating the specified lamp. Fluorescent lamp color temperature shall be 3500K. Compact fluorescent twin tube /dual twin tube lamps shall be Osram or Philips, 82 CRI, minimum 10,000 hours rated. Long fluorescent twin tube lamps shall be Osram or Philips, 82 CRI, 3150 initial lumens, minimum 20,000 hours rated. F32T8 fluorescent lamps shall be rapid start, energy saving type, minimum 75 CRI, minimum 2850 initial lumens and minimum 20,000 hours rated. Lamps shall be Sylvania Osram or Philips, equal to Sylvania #F032 /RS. All surface and recessed ceiling fixtures installed on grid or tile ceilings shall be installed to agree with module of ceiling either displacing a tile, or unit on center of tile, or centered on grid lines. Provide fixtures and /or fixture cutlet boxes with hangers to properly support fixture weight. All lighting fixtures installed in or on suspended ceiling systems shall be anchored directly to the building structural system above (anchored per NEC). Such anchoring shall be independent of the ceiling support system. All fixtures shall be installed plumb and level. Support surface mounted fixtures greater than 2 feet in length at a point in addition to the outlet box fixture stud. Replace defective lamps for a period of one year following the time of Substantial Completion. Where used for temporary lighting prior to time of Substantial Completion, replace all incandescent lighting fixture lamps, as well as any tamps which are defective, damaged or burned out. For all existing fixtures which are scheduled for reuse, remove from existing ceilings during demolition; protect during construction; clean, service (if required), relamp (with lamps to match building standard or per this section as noted) and reinstall at locations indicated. For all existing fixtures which are scheduled to be removed and turned over to Owner, the fixtures shall be disconnected, carefully removed and turned over to Owner. Transfer such fixtures to storage area as directed in field. 18. MECHANICAL EQUIPMENT Provide all conduit and outlet boxes as required for all control wiring and thermostats. Furnish and install power wiring and make line connections to all heating, ventilating and air conditioning equipment. Electrical Contractor shall examine the approved drawings of all branches and shall wire and connect all motors, disconnects, control devices and other items requiring electricity for operation. This contractor shall make the necessary electrical connections between the specified equipment and the junction box near equipment with flexible metallic conduit and matched connectors. No flexible conduil shall be exposed in finished rooms. Each motor shall have disconnect switch or manual starter installed by this contractor ahead of motor or motor magnetic starter. The Electrical Contractor shall provide control and interlock wiring as specifically indicated on the drawings. All other control wiring required for operation of the systems shall be provided by the Heating Contractor. REVIEWED .FOR COMPLIANCE WITH NFPA70 - NEC AUG 08 2012 City o .TuI I BUILDING DIVISION 19. FIRE ALARM WORK (FULL FIRE ALARM) Where indicated on drawings, remove existing fire alarm devices in affected areas and protect during demolition and construction phases. Clean and reinstall these existing devices as indicated on drawings. Relocate devices as indicated on drawings and extend conduit and wiring as required. Modify and /or extend related existing wiring in conduit as required. Fire alarm system devices (smoke detectors, pull stations, bells, strobes, etc.) shall be of the same manufacturer as, and compatible with, the existing building fire alarm system. Provide auxiliary contacts if required for special applications. All strobe alarms shall be ADA compliant, minimum 75cd per ADA. All new wiring shall be installed in strict accordance with manufacturer's requirements and in conduit (3/4" minimum). Fire alarm system wiring shall be installed in a raceway system separate from security sub - system wiring where /if applicable. The installation shall include a complete system test of the equipment by the local representative of the system installed. This test shall be performed in the presence of representatives of the owner, engineer, and local fire department. The fire alarm system supplier shall provide to the electrical contractor a complete set of floor plan drawings showing conduit sizes and number of Y PP P P conductors required to all components plus detailed wiring connections required at each type of device. It shall be the responsibility of the fire alarm systems manufacturer to submit these drawings to the state fire marshall's office (or other authority having jurisdiction) for approval. This action shall be taken during the shop drawing procedure. The system must be approved by this authority and a copy submitted to the engineer with the shop drawing submittal. All fire alarm system working drawings shall be provided by manufacturer. Provide all required modifications (cards, power supplies, hardware, firmware, software, etc.) to the existing fire alarm system as required to render the entire extension fully operable. Provide all required 20A/120VAC power as required to energize all new fire alarm related components. This requirement applies whether or not such power work is shown on the drawings. Branch circuits serving fire alarm related equipment shall be dedicated to fire alarm related equipment only. Smoke detector locations shall not exceed the rated coverage of the detector and, in general, shall be no more than 15 feet from a wall or 30 feet from supply air diffuser. Provide contact bases for all applications where auxiliary apart. Smoke detectors shall not be installed within 3 feet om a supp y d pp contacts are required. in devices shall be red ADA-compliant units (with minimum 75 candela ADA-compliant strobes) wall The audio /visual and visual only alarm indicating de ces s p ( p ) mounted at 6'8" as shown on plans. Strobe units shall be synchronized wherever required by any authority having jurisdiction, including ADAAG. Additionally, where required by local authority, the strobes must meet ANSI S3.41 temporal code. The waterflow switches, tamper switches and pressure switches shall be provided by the sprinkler contractor. The electrical contractor shall wire and provide the related monitor modules as required. P q Provide isolation modules as required to isolate wire to wire shorts on a data loop to limit the number of other modules or detectors that are incapacitated by the short circuit fault and /or grounds. Isolation modules shall be part of the smoke detector base. The isolation modules shall permit the entire system to operate independently of the area disconnected by the isolation module due to wiring faults. Provide monitor modules as required to interface "non- intelligent" devices into the system as shown on the drawings (i.e. sprinkler flow switches, tamper switches, etc.). Provide control modules for all auxiliary devices including all supervised control functions such as air handler shutdowns. Exterior /roof mounted duct smoke detectors shall be in a NEMA -4x enclosure. The installation shall include a complete system t es t of the equipment b the local representative of the system installed. This test shall be performed in the presence of representatives of the Owner, Engineer, and local fire department. The fire alarm system supplier shall provide to the electrical contractor a complete set of floor plan drawings showing conduit sizes and number of conductors required to all components plus detailed wiring connections required at each type of device. It shall be the responsibility of the Fire Alarm Systems Manufacturer to submit these drawings to the State Fire Marshall's Office for approval. This action shall be taken during the shop drawing procedure. The system must be approved by this State Inspection Agency and a copy submitted to the Engineer with the shop drawing submittal. All fire alarm system working drawings shall be provided by manufacturer. 20. ELECTRICAL DISTRIBUTION EQUIPMENT DISCONNECTS & FUSES: Subject to compliance with requirements, provide equipment of one of the following (for each type and rating): Allen - Bradley Co. General Electric Co. Siemans /ITE Square D Co. Westinghouse/Cutler-Hammer Disconnect switches shall be equal to Square D Type HD. All Safety Switches /Disconnects shall be heavy duty, safety type, quick make and quick break and externally operated. Unless noted otherwise on drawings or directed otherwise in field, all disconnect switches shall be fused. Unless noted otherwise on drawings or directed otherwise in field, brace all disconnect switches for 200,000 A.I.C. Provide heavy -duty switches, with fuses of classes and current ratings indicated and UL listed for use as service equipment under UL Standard 98 or 869. See Section "FUSES" for specifications. Where current limiting fuses are indicated, provide switches with non - interchangeable feature suitable only for current limiting type fuses. Install disconnect switches within sight of controller position unless otherwise indicated. FUSES: Subject to compliance with requirements, provide fuses of one of the following. All fuses shall be of the same manufacturer: Bussman, LittelFuse, Shawmut (A4BQ series). Except as otherwise indicated, provide fuses of types, sizes, ratings, and average time - current and peak let- through current characteristics indicated, which comply with manufacturer's standard design, materials, and constructed in accordance with published product information, and with industry standards and configurations. Fuses 1 ampere through 600 amperes shall be rejection type. Fuses 601 amperes through 6000 amperes shall be Hi -Cap, bolt type. Provide factory fuse identification labels, installed on the inside of the door of each switch indicating type and size of fuses installed. For types and ratings required, furnish additional fuses, amounting to 10 percent of fuses supplied, but not less than one set of 3 of each kind. Each fuse shall be clearly factory marked with classification, characteristics, ampere ratings, voltage ratings, etc. Fuses shall not be shipped installed in switches nor shall they be installed in the equipment until the equipment until the equipment is ready to be energized. All fuses shall be of the same manufacturer. Prior to installing fuses for protection of specific equipment, motors, etc., verify recommended fuse size /type in field from respective equipment manufacturer. If a conflict in fuse size /type results between manufacturer's recommendations and above specifications, contact engineer. Provide all required fuses under base bid. Install fuses in fused switches. LIGHTING CONTACTORS All contactors shall be equipped with external green pilot lights in cover and external H.O.A. selector switches in cover. Lighting contactors shall be wired so 9 P 9 9 9 that the "AUTO" position is the normal activated condition (i.e. photocell controlled, photocell /time -clock controlled, remote switch controlled, BAS controlled, etc.); the "OFF" position shall be a manual override to turn lighting off; the "HAND" position shall be a manual override to turn lighting on. All contactors shall be equipped with field convertible N.O. /N.C. contacts and descriptive nameplates. Lighting contactors shall be equal to Square D Class 8903 (or Allen - Bradley Bul. 500L -BA "94 series) for tungsten & ballast lighting and resistance heating loads. Lighting contactors shall be electrically held in factory NEMA 1 enclosure, with 120V coil and characteristics as indicated on drawings or as required. "Dry" contacts shall be rated at 30A, 250V or 600V as required. Provide number of poles (minimum of four poles) and number of contactors as required for each application. Verify all coil voltage ratings in field. TIMECLOCKS Multi- Purpose Time Clock shall be equal to Intermatic #ET70415C (or equal by Paragon, Tork). Time clock shall be programmable 365 day, 24 hour with override controls. Unit shall be 4 channel. Provide all required external contactors, relays, etc. to render the control systems fully operational. Verify zone control requirements in field prior to rough -in. Provide battery backup extended power carryover. Custom programming shall be configured as specified and detailed on plans. PANELBOARDS: Subject to compliance with requirements, provide panelboard products of one of the following (for each type and rating of panelboard and enclosure): Square D Company, General Electric Company, Siemens /ITE, Westinghouse /Cutler- Hammer. Panelboards shall bear UL labels for their specific applications. Panelboards shall be suitable for service voltage with number of branch circuits of capacity scheduled. Unless otherwise indicated, panelboards and sections thereof, if any, shall have main lugs only of capacity equal to, or greater than, the rating or setting f the over the current protective device next back on the line. All circuit breaker panelboard bus assemblies shall be of the distributed (sequence) 9 P bussing type throughout, so that any 2 adjacent single pole breakers and /or spaces shall be replaceable by a 2 pole internal common trip breaker, and any 3 adjacent single pole breakers and /or spaces shall be replaceable by a 3 pole internal common trip breaker, 15 amp through 70 amp inclusive, without disturbing any other breaker. All panelboards shall be UL listed and labeled for use as service entrance equipment where being used as such. Distribution panels shall be Square D I -Line. 480Y/277 volt high voltage panels shall be Square D NF. 208Y/120V Lighting and Appliance panelboards shall be equal to Square D NQOD with bolt -on branch breakers. All bussing shall be copper. All branch circuit breakers shall be full ambient compensated thermal magnetic molded case with quick -make and quick -break action and positive handle trip indication, both on manual and on automatic operation. Breakers shall be of the over - the - center toggle operating type with the handle going to a position between "on" and "off' to indicate automatic tripping. All circuit breakers shall be full size. "Tandem" or "split" breakers shall not be permitted. All multi -pole breakers shall have internal common trip with all load side box lugs of one breaker in the same gutter. All circuit breakers shall have sealed cases to prevent tampering. All 15 and 20 ampere branch circuit breakers shall be UL Listed as SWD (switching duty). All 15 -70 ampere branch circuit breakers shall be HACR Type. All GFI circuit breakers shall be UL Class A with maximum threshold of 5 mA. All branch circuit breakers serving all ballasted (fluorescent/HID) lighting loads shall be HID rated. Provide 20 ( + / -) non - padlock type breaker lock -on devices and install on branch breakers as directed in field (night lights, computers, security, etc.). Provide detailed typewritten schedules for all panelboards. Circuit breakers shall be furnished as scheduled on the drawings or as otherwise required based on field determinations. Provide all electrical distribution related equipment with appropriately braced bussing and properly rated breakers, fuses, etc. for the available fault currents. In existing buildings where fault current values are not indicated on drawings, coordinate with existing "upstream" distribution equipment provide equipment AIC ratings to meet or exceed same. Fill out panelboard's circuit directory card upon completion of installation work. Directories shall be neatly typewritten. All panelboard directories shall include the actual room names /numbers that are selected for interior signage /designation. All recessed panelboards shall be provided with a minimum of three 1 -1/4" empty conduits terminated to a single 12" X 12" X 6" deep junction box above accessible ceiling. TRANSFORMERS: Ll)-O7 05 Power Distribution Transformers shall be Square D Dry Type. Provide copper windings. Provide 4" high concrete housekeeping pad (with chamfered edges) for all floor mounted transformers. Install units on vibration mounts; comply with manufacturer's indicated installation method. 90% SET- 1-19 -12 Y � 0 0 YOOZ zcnote Om O MO). -u oz • SEAL: AEROSOLES EIF-1E;Tifirlit2 1,57 JUL 2 5 2012 00 QW r 00 Y IJJ ~ Q Z w 0 N ce U N Lij W Z I O w in U 0ONQU Q • CL I Li N 1- J W W J _ I- O W L- Z V1 I- X I- Q I- O WZMQ I- w14) W V1 3 F- to v) SHEET TITLE: ELECTRICAL SPECIFICATIONS REVISIONS: NO: DATE: BY: PROJECT NO: DRAWN BY: E 12874.00 SCHMID, SOSA E -4 SHEET OF