HomeMy WebLinkAboutPermit EL12-0794 - INTERNAP DATA CENTERINTERNAP DATA CENTER 3355 S 120 PL EL1 2-0794 City oilitukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: httn: / /www.TukwilaWA.gov Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Project Name: INTERNAP DATA CENTER ELECTRICAL PERMIT Permit Number: EL12 -0794 Issue Date: 09/17/2012 Permit Expires On: 03/16/2013 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD , 4TH FLOOR 98168 Contact Person: Name: JUSTIN HAGOOD Address: 15323 NE 90 ST , REDMOND WA, 98052 Contractor: Name: PRECISION ELECTRIC GROUP INC Address: 15323 NE 90TH ST , REDMOND WA 98052 Contractor License No: PRECIEG969PH Phone: 206-948-9805 Phone: (425)823 -8600 Expiration Date: 10/08/2012 DESCRIPTION OF WORK: PROVIDE AND INSTALL (2) 225 VOLT PANELS AND (34) 208 VOLT CIRCUITS. Value of Electrical: NRES: $20,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: SEATTL CITY LI Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: $545.63 2008 Date:q /Z) I hereby certify that I have read and examine: this pe `'t and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the - / • r - ce of ork. I am authorized to sign and obtain this electrical permit. Q� / Signature: G -- Date: / ! A.Z Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL12 -0794 Printed: 09 -17 -2012 PERMIT CONDITIONS Permit No. EL12 -0794 * *ELECTRICAL ** • 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -0794 Printed: 09 -17 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Electrical Permit No. !_ Li 0) q q Project No. Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: 3355 S 120th pL Internap Data Center King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes z..No PROPERTY OWNER Name: Justin Hagood Address: 15323 NE 90th St Name: Internap Phone: (206) 948 -9805 Fax: (425) 823 -8655 Email: Justinh @pegiinc.com Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Justin Hagood Address: 15323 NE 90th St City: Redmond State: WA Zip: 98052 Phone: (206) 948 -9805 Fax: (425) 823 -8655 Email: Justinh @pegiinc.com ELECTRICAL CONTRACTOR INFORMATION Company Name: Precision Electric Group Inc Address: 15323 NE 90th Street City: Redmond State: WA Zip: 98052 Phone: (425) 823 -8600 Fax: (425) 823 -8655 Contr Reg No.: PRECIEG969PH Exp Date: 12/31/2012 Tukwila Business License No.: BUS - 0993459 Valuation of Project (contractor's bid price): $ 20,000 Scope of Work (please provide detailed information): Provide and install (2) 225 volt panels and (34) 208volt circuits. Will service be altered? Yes ❑ No Adding more than 50 amps? WI Yes ❑ No Type of Use: Electrical Panel Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel m Tenant Improvement Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy i Seattle City Light H: Applications\Fornss- Applications On Line2011 Applications\Electncal Permit Application Revised 8- 9- I1.docs Revised: August 2011 bh Page 1 of 2 RRESIDENTIAL NEW RESIDENTIAL SERVICE. ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES Service change or alteration $81.90 (no added/altered circuits) Service change with added/altered circuits $81.90 number of added circuits $11.55 ea Circuits added/altered without service change $54.60 (up to 5 circuits) Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea Meter /mast repair $68.25 Low voltage systems $59.85 (alarm, furnace thermostat) MULTI-FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service ,(generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding age or outbuilding) ❑ Camivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS'APPLICATION AND I6IOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON; ANDI AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Sign. ure: R ORE ECTRICAL CO ' CTOR: Date: 08/22/2012 Print Name Justin Hagood Day Telephone: (206) 948 -9805 Mailing Address: 15323 NE 90th Street H:WpplimtionsWomts- Applimttons On Line \2011 Applications\Electncal Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Redmond City WA 98052 State Zip Page 2 of 2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Applicant: INTERNAP DATA CENTER RECEIPT Permit Number: EL12 -0794 Status: PENDING Applied Date: 08/22/2012 Issue Date: Receipt No.: R12 -02422 Payment Amount: $545.63 Initials: WER Payment Date: 08/22/2012 01:48 PM User ID: 1655 Balance: $0.00 Payee: JUSTIN HAGOOD TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 04573B ACCOUNT ITEM LIST: Description 545.63 Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 436.50 000.345.832.00.00 109.13 Total: $545.63 doc: Receiot -06 Printed: 08 -22 -2012 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. (1,476.7lt CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431 -2451 Project: p� ( Type of Inspection: job Address: S ,5- t?b,�. Date Called: Special Instructions: Date Wanted: 3/1 a.m�. Requester: ' •' Phone No: JApproved per applicable codes. Corrections required-prior to approval. COMMENTS: I Inspector: n REINSPECTION FEE REQUIRED. Prior to next inspection; fee must be` paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection PER4JCO' s • COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0794 DATE: 08 -22 -12 PROJECT NAME: INTERNAP DATA CENTER SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS-pi Ivision Public Works ❑ Fire Prevention Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 171, Incomplete DUE DATE: 08-23 -12 Not Applicable Comments: Permit. Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S I ITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09-20-12 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 02 -01 -2013 JUSTIN HAGOOD 15323 NE 90 ST REDMOND WA 98052 a..� rrtnient 9 **Ainmut1.1 - Development RE: Permit No. EL12 -0794 1NTERNAP DATA CENTER 3355 S 120 PL TUKW Dear Permit Holder: Irri%H;agg0 ti k11%lMayor J rck Perce Drreetor In reviewing our current records, the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/16/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 03/16/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, -9 Bill Rambo Permit Technician File: Permit File No. ELI2 -0794 ac !.$ Boulevard 't#:] ;113 7-9 • • 431 36615 Contractors or Tradespeople Per Friendly Page Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name PRECISION ELECTRIC GROUP INC UBI No. 602434703 Phone 4258238600 Status Active Address 15323 Ne 90Th St License No. PRECIEG969PH Suite /Apt, License Type Electrical Contractor City Redmond Effective Date 10/8/2004 State WA Expiration Date 10/8/2012 Zip 98052 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Master Electrician INFORMATION License DAVISMD962DH Name DAVIS, MARK D Status Active Business Owner Information Name Role Effective Date Expiration Date FRANKE, PATRICK J Agent 10/08/2004 Bond Amount DAVIS, MARK D President 10/08/2004 WA28604 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 Merchants Bonding Co (Mutual) WA28604 10/20/2011 Until Cancelled $4,000.00 10/10/2011 3 First National Ins Co of Ameri 6572196 10/20/2008 Until Cancelled $4,000.00 10/08/2008 2 NATIONWIDE MUTUAL INS CO 7900637867 10/20/2005 Until Cancelled 01/05/2010 $4,000.00 12/08/2006 1 DEVELOPERS INSURANCE COMPANY 574104C 10/07/2004 Until Cancelled 11/29/2007 $4,000.00 10/08/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information No records found for the previous 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 09/17/2012 Fad. COPY Permit Na <Q Pan review approval is subplot to efrOM and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field ' conditions is acknowledged: By ', City Of 1Ukwila BUILDING DIVISION REVISIONS No changes shag made to the cope of work without prior approval O Tukwila Building Division.. • t dQTr: Revisions willdd require additional plan revaew feeslt{ µi and may include a TO GENERATOR TO SERVICE SWITCHBOARD #1 SWITCHBOARD #1 ATS #1 4000A 30, 3W 480V SB- UPSBP1 UPS BYPASS SWITCHBOARD 3000A BUS, 480V, 30, 3W + GND, 100KAIC TO UPS INPUT SWITCHBOARD 3000A 3000AT F 3000AF 3000AT UPS DISTRIBUTION SWITCHBOARD - 3000A BUS, 480V, 30, 3W + GND, 65KAIC SHADING INDICATES NEW WORK IN THIS CONTRACT. 1 600AT ) 600AT ) 600AT 1 600AT ) 600AT 600AT T -1A 300 kVA XFMR T -2A 300 kVA XFMR FLAG NOTES USE EXISTING 225A -3P BREAKER T -3A T -4A T -5A T -6A 300 kVA 300 kVA 300 kVA 300 kVA XFMR XFMR XFMR XFMR 600AF 600AT T -7A 300 kVA 480- 208Y/120V EXISTING 800A FEEDER 600AF 600AF 600AT ) 600AT T -6B 300 kVA XFMR 600AF 600AT T -5B 300 kVA XFMR EXISTING 600A FEEDER DP- CPP -7A 800A DISTRIBUTION 208Y/120V, 30, 4W + GND, 42KAIC 800AF 800AT 225AF 225AF 225AF 225AF 225AT ) 225AT ) 225AT 225AT CPP -7A -1 42KAIC CPP -7A -2 42KAIC 0 7,7x5,4 ‚(4/ L SPARE 2 -1/2 "C - 4 #4/0 CU & 1 #4 CU GND PARTIAL EXISTING ONELINE DIAGRAM NOT TO SCALE 600AF ' 600AF 600AT J 600AT T -3B 300 kVA XFMR T -4B 300 kVA XFMR T -7B 300 kVA 480- 208Y/120V c=)-- EXISTING 800A FEEDER 600AF 600AF J 600AT -' 600AT T -2B T -1B 300 kVA 300 kVA XFMR XFMR DP- CPP -7B 800A DISTRIBUTION 208Y/120V, 30, 4W + GND, 42KAIC 800AF 800AT 225AF 225AF 225AF 225AT 225AF 225AT ) 225AT ) 225AT CPP -7B -1 42KAIC CPP -7B -2 42KAIC SPARE 2 -1/2 "C - 4 #4/0 CU & 1 #4 CU GND SHORT CIRCUIT CALCULATIONS DESCRIPTION CIRCUIT DEFINITION CONDUIT # IN LENGTH MAT'L SIZE PARALLEL CONDUCTOR OHMS /MFT R X CIRCUIT IMPEDENCE OHMS R X Z AVAILABLE FAULT CURRENT MINIMUM PANEL RATING AVAILABLE FAULT CURRENT PANEL DESCRIPTION Panel Amps Max Amps L - L Volts L - N Volts Phase Wire A.I.C. M.L.O. Main C.B. Main Fu. Flush Surface Bond Gnd. Iso. Gnd. Feed Thru Sub Feed Top Feed Btm. Feed 225 200 208 120 3 4 42k Amp P Rec UPS DIST SWITCHBOARD Motor Ltg Other Total 1 (USE EXTG PANEL RATING) A 30 0.00000 0.00426 0.00426 65,000 FEEDER TO XFMRS T7 -A /T7B 10 M 350 kCMIL CU 2 0.039 0.050 0.00020 0.00025 0.00032 3 - (AIC SHOWN AT END OF FEEDER - - 1.9 1.9 0.00020 0.00451 0.00452 61,341 C TRANSFORMERS T7 -A & T7 -B 2 IMPEDENCE © 120 VOLTS 1.9 7 0.00004 0.00085 0.00085 A - 300 kVA XFMR 0 5.5% Z 0.00258 0.00749 0.00792 1.9 1.9 AFC ® XFMR SECONDARY SERVER OUTLET B 0.00262 0.00833 0.00874 13,737 42,000 NOTES TO CALCULATIONS: 1. CALCULATIONS ARE BASED ON OHMIC METHOD, 277 VOLTS LINE TO GROUND FAULT. 2. CONDUCTOR IMPEDANCE IS BASED ON NATIONAL ELECTRICAL CODE TABLE 9. 3. CONDUIT MATERIAL: M =MAG, N= NON -MAG SEPARATE PERMIT IIIECIUIFIED FOR: thicianlad pkinangliscidall 3 OM Piping City ANIK2Mai. PANEL: CPP -7A -3 Project: 1 Quantcast Location : Quantcast TI Space Fed From : PANEL DP- CPP -7A Section: Ckt No. CIRCUIT NAME p h Cb /Fu Load Kva PANEL DESCRIPTION Panel Amps Max Amps L - L Volts L - N Volts Phase Wire A.I.C. M.L.O. Main C.B. Main Fu. Flush Surface Bond Gnd. Iso. Gnd. Feed Thru Sub Feed Top Feed Btm. Feed 225 200 208 120 3 4 42k Amp P Rec Heat Motor Ltg Other Total 1 SERVER OUTLET A 30 2 1.9 1.9 3 - B - - 1.9 1.9 5 SERVER OUTLET C 30 2 1.9 1.9 7 - A - - 1.9 1.9 9 SERVER OUTLET B 30 2 1.9 1.9 11 - c - - 1.9 1.9 13 SERVER OUTLET A 30 2 1.9 1.9 15 - B - - 1.9 1.9 17 SERVER OUTLET C 30 2 1.9 1.9 19 - A - - 1.9 1.9 x 21 SERVER OUTLET B 30 2 1.9 1.9 23 - c - - 1.9 1.9 25 SERVER OUTLET A 30 2 1.9 1.9 x _ _ _ _ x 27 - B - - 1.9 1.9 29 SERVER OUTLET C 30 2 1.9 1.9 31 - A - - 1.9 1.9 33 SERVER OUTLET B 30 2 1.9 1.9 35 - C - - 1.9 1.9 37 SPACE ONLY A 39 SPACE ONLY B 41 SPACE ONLY C 2 SERVER OUTLET A 30 2 1.9 1.9 LOAD SUMMARY ( Total, All Sections ) Rec Kva Heat Kva Motor Kva Ltg Kva Other Kva 64.1 Phase A 22.6 Phase B 20.8 Phase C 20.7 Conn. Kva 64.1 Conn. Amps 178 Demand Kva 64.1 Demand Amps 178 4 - B - - 1.9 1.9 6 SERVER OUTLET C 30 2 1.9 1.9 8 - A - - 1.9 1.9 10 SERVER OUTLET B 30 2 1.9 1.9 12 - C - - 1.9 1.9 14 SERVER OUTLET A 30 2 1.9 1.9 16 - B - - 1.9 1.9 18 SERVER OUTLET C 30 2 1.9 1.9 20 - A - - 1.9 1.9 22 SERVER OUTLET B 30 2 1.9 1.9 24 - C - - 1.9 1.9 26 SERVER OUTLET A 30 2 1.9 1.9 28 - B - - 1.9 1.9 30 SERVER OUTLET C 30 2 1.9 1.9 32 - A - - 1.9 1.9 34 SPACE ONLY B 36 SPACE ONLY C 38 , SPACE ONLY A 40 SPACE ONLY B 42 SPACE ONLY C REMARKS : NEW PANEL first 10 kva rec ® 100% + balance 0 50% = largest motor 0 125% + balance ® 100% lighting 0 125% = heating 0 100% = other 0 100% = 64.1 PANEL: CPP -7B -3 Project: 1 Quantcast Location : Quantcast TI Space Fed From : PANEL DP- CPP -713 Section: Ckt No. CIRCUIT NAME P h Cb /Fu Load Kva PANEL DESCRIPTION Panel Amps Max Amps L - L Volts L - N Volts Phase Wire A.I.C. M.L.O. Main C.B. Main Fu. Flush Surface Bond Gnd. Iso. Gnd. Feed Thru Sub Feed Top Feed Btm. Feed 225 225 208 120 3 4 42k Amp P Rec Heat Motor Lt9 Other Total 1 SERVER OUTLET A 30 2 1.9 1.9 3 - B - - 1.9 1.9 5 SERVER OUTLET C 30 2 1.9 1.9 7 - A - 1.9 1.9 9 SERVER OUTLET B 30 2 1.9 1.9 11 - c . - - 1.9 1.9 13 SERVER OUTLET A 30 2 1.9 1.9 15 - B - - 1.9 1.9 17 SERVER OUTLET C 30 2 1.9 1.9 19 - A - - 1.9 1.9 x 21 SERVER OUTLET B 30 2 1.9 1.9 23 - C - - 1.9 1.9 25 SERVER OUTLET A 30 2 1.9 1.9 x _ _ _ _ _ x 27 - B - - 1.9 1.9 29 SERVER OUTLET C 30 2 1.9 1.9 31 - A - - 1.9 1.9 33 SERVER OUTLET B 30 2 1.9 1.9 35 - c - - 1.9 1.9 37 SPACE ONLY A 39 SPACE ONLY B 41 SPACE ONLY C 2 SERVER OUTLET A 30 2 1.9 1.9 LOAD SUMMARY ( Total, All Sections ) Rec Kva Heat Kva Motor Kva Ltg Kva Other Kva 64.6 Phase A 22.8 Phase B 20.9 Phase C 20.9 Conn. Kva 64.6 Conn. Amps 179 Demand Kva 64.6 Demand Amps 179 4 - B - - 1.9 1.9 6 SERVER OUTLET C 30 2 1.9 1.9 8 - A - 1.9 1.9 10 SERVER OUTLET B 30 2 1.9 1.9 12 - C - - 1.9 1.9 14 SERVER OUTLET A 30 2 1.9 1.9 16 - B - - 1.9 1.9 18 SERVER OUTLET C 30 2 1.9 1.9 20 - A - - 1.9 1.9 22 SERVER OUTLET • B 30 2 1.9 1.9 24 - C - - 1.9 1.9 26 SERVER OUTLET A 30 2 1.9 1.9 28 - B - - 1.9 1.9 30 SERVER OUTLET C 30 2 1.9 1.9 32 - A - - 1.9 1.9 34 SPACE ONLY B 36 SPACE ONLY C 38 SPACE ONLY A 40 SPACE ONLY B 42 SPACE ONLY C REMARKS : NEW PANEL first 10 kva rec 0 100% + balance 0 50% = largest motor 0 125% + ba once 0 100% lighting 0 125% _ heating ® 100% = other 0 100% = 64.6 PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone: 425- 823 -8600 Fax: 425- 823 -8655 CASH', IV ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425- 402 -9400 Fax: 425- 402 -9402 NFPAio City of T '� I iIa BUfLDINC $TS►O. REVIEWED COMPLIANCE WI NECrH SEP o 4 2012 Project Title: I \TF,RNAP DATA CENTER PHASE II] QUANTCAST Tenant Improvements 3355 S. 120th Place Tukwila, WA 98168 Sheet Title: ONELINE DIAGRAM PANEL SCHEDULI-{;S RECEIVED AUG 222012 PERMIT CENTER ELL2 07q's Designed By: MSC Drawn By: CJP Project No: Date: 12097 08/20/12 Sheet Number: N;1.0