Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL12-0960 - CITY OF TUKWILA - POOL
CITY OF TUKWILA POOL 4414 S 144 ST CANCELLED 04 -15 -13 EL1 2-0960 City ukwila i Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1523049106 Address: 4414 S 144 ST TUKW Project Name: CITY OF TUKWILA - POOL ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL12 -0960 11/13/2012 05/12/2013 Owner: Name: TUKWILA SCHOOL DISTRICT Address: 4640 144TH ST , SEATTLE WA 98168 Contact Person: Name: DAVE ROBINAUGH Address: 5005 THIRD AV S , SEATTLE WA, 98134 Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA 98124 Contractor License No: MCKINCL942DN Phone: 206 - 832 -8352 Phone: 206 762 -3311 Expiration Date: 03/15/2014 DESCRIPTION OF WORK: UPGRADE ELECTRICAL CONNECTIONS TO EXISTING LOCKER ROOM FANS, BOILER ROOM EQUIPMENT AND AIR HANDLING UNITS. INSTALL NEW VFD'S TO POOL CIRCULATION PUMP AND AHU. Value of Electrical: NRES: $12,730.00 Fees Collected: RES: . $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: National Electrical Code Edition: $395.13 2008 VA9.3/` Date: I(117)11t I hereby certify that I have read and e . n: d this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied ' th, hether specified herein or not. The granting of t permit d; es not p construction o — . erfo Signature: ume to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this electrical permit. Print Name: o 6-juky Date: / 3 , " Jv OZ o Z This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL12 -0960 Printed: 11 -13 -2012 PERMIT CONDITIONS Permit No. EL 12 -0960 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -0960 Printed: 11 -13 -2012 CITY OF TUKIA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Li^ Cl �Q 0 Project No. .1)14)^`-t Date Application Accepted: 10^ Date Application Expires: {---( 0 15 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 4414 South 144th Tenant Name: City of Tukwila King Co Assessor's Tax No.: 1523049106 Suite Number: New Tenant: PROPERTY OWNER Name: Dave Robinaugh Address: 5005 3rd Ave S Name: City of Tukwila Phone: (206) 832 -8352 Fax: Email: davero @mckinstry.com Address: 4414 South 144th City: Tukwila State: WA Zip: 98168 CONTACT PERSON, — person receiving all project communication Name: Dave Robinaugh Address: 5005 3rd Ave S City: Seattle State: WA Zip: 98134 Phone: (206) 832 -8352 Fax: Email: davero @mckinstry.com Floor: ❑ Yes I..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Upgrade electrical connections to existing locker room fans, boiler room equipment, and air handling unit. Install new VFD's to pool circulation pump and AHU. 12,730 Will service be altered? ❑ Yes I No Type of Use: Adding more than 50 amps? ❑ Yes 'No Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy 1' Seattle City Light H:\Applications\Forms- Applications On Line \20I I Applications \Electrical Permit Application Revised 8 -9 -1 I.docx Revised: August 2011 bh • Remodel ❑ Telecommunication ❑ Tenant Improvement ❑ Temporary Service Page I of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: iµ^ Date: 10/10/2012 Print Name: Dave Robinaugh 1 Day Telephone: (206) 832 -8352 Mailing Address: 5005 3rd Ave S Seattle WA 92,134 City H:Wpplications\Forms- Applications On Line \2011 Applications\Electrical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1523049106 Address: 4414 S 144 ST TUKW Suite No: Applicant: CITY OF TUKWILA - POOL RECEIPT Permit Number: EL12 -0960 Status: APPROVED Applied Date: 10/10/2012 Issue Date: Receipt No.: R12 -03089 Payment Amount: $395.13 Initials: JEM Payment Date: 11/13/2012 09:18 AM User ID: 1165 Balance: $0.00 Payee: PARKS ACCT NO. 11263001.1000.107 TRANSACTION LIST: Type Method Descriptio Amount Payment Other Authorization No. ACCOUNT ITEM LIST: Description 395.13 Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 316.10 000.345.832.00.00 79.03 Total: $395.13 rinr: Rarpint_f1R Printari• 11- 13 -7f112 TO: FROM: DATE: SUBJECT: MEMORANDUM Laurie Anderson Brenda Holt 04/23/2013 City of Tukwila - Pool Permit Number EL12 -0960 Please provide a refund to the City of Tukwila Parks Account Number 11263001.1000.107 in the amount of $252.88 from the Electrical Permit Non - Residential Account Number 000.322.101.00.00. There were overlapping/duplicate electrical permits pulled for the City of Tukwila Pool Project (permits EL12-0960 and EL 12- 1115). McKinstry has requested that permit EL12-0960 be cancelled and refunded due to the fact that the work under this permit received approval through permit EL 12 -1115. Per the direction of the Building Official, an eighty percent refund of permit fees is to be granted. Thank you! Jennifer Marshall From: Bob Benedicto Sent: Tuesday, April 23, 2013 9:27 AM To: Bill Rambo; Jennifer Marshall Subject: FW: City of Tukwila Pool Permit EL 12 -0960 Attachments: DCD Letter II.pdf; DCD Letter.pdf O.K. to prepare refund of this permit for McKinstry. See Request letter. Thanks. From: Andrew Gray [mailto:andrewg McKinstry.com] Sent: Monday, April 22, 2013 6:36 PM To: Bob Benedicto Subject: RE: City of Tukwila Pool Permit EL 12 -0960 Thank you, Bob. I attached the request for a refund as you indicated. I also attached the original letter for your reference. Let me know if you have any questions. Thanks, Andy Gray Superintendent c 206.930.4729 McKinstry Consulting 1 Construction 1 Energy 1 Facility Services www.mckinstry.com From: Bob Benedicto j mailto :Bob.Benedicto @TukwilaWA.clovl Sent: Friday, April 19, 2013 9:51 AM To: Andrew Gray Subject: RE: City of Tukwila Pool Permit EL 12 -0960 Good Morning Andrew, I have considered your situation and have directed the permit Tech to close this permit. If you require a refund on this permit you must request it in writing under separate cover. The refund will be made to the original applicant on file. From: Andrew Gray [mailto:andrewg@McKinstrv.com] Sent: Friday, April 19, 2013 9:46 AM To: Bob Benedicto Cc: Dave Robinaugh Subject: FW: City of Tukwila Pool Permit EL 12 -0960 1 I wonder if you've had a chance to consider this situation and if you might be able to offer a resolution. Please don't hesitate to contact either myself or Dave Robinaugh (cc'd) if you have any questions. Thank you, Andy Gray Superintendent c 206.930.4729 McKinstry Consulting 1 Construction 1 Energy 1 Facility Services www.mckinstry.com From: Andrew Gray Sent: Monday, April 15, 2013 1:54 PM To: 'bob.benedicto @tukwilawa.gov' Subject: City of Tukwila Pool Permit EL 12 -0960 Bob, I stopped by the Department of Community Development office to discuss the open permit at Tukwila Pool EL12 -0960. The specialist I spoke with suggested I write a letter which I've attached. Please let me know if you have any questions, Thanks Andy Gray Superintendent c 206.930.4729 McKinstry Consulting 1 Construction 1 Energy 1 Facility Services www.mckinstry.com This email is the property of McKinstry or one of its affiliates and may contain confidential and/or privileged information. If you are not the intended recipient or have received this e-mail in error please notify the sender immediately and delete this e-mail. Any unauthorized copying, disclosure or distribution of the material in this e -mail is strictly forbidden. 2 Monday, April 22, 2013 Bob Benedicto, RA Building Official Department of Community Development 6300 Southcenter Boulevard Tukwila, WA 98188 RE: Request for Refund of Fees Paid for Permit EL12 -0960 City of Tukwila Pool 4414 S 144th St Tukwila, WA 98168 Bob; .r vuvitA APR X32013 PERmacav ,EA I would like to request a refund of the fees paid for Permit EL12 -0960. As described in my letter to you last week regarding this permit, we've discovered that another permit (EL12 -1115) obtained by Betschart Electric overlapped the scope of work covered by this permit. This permit was therefore unnecessary and never utilized although all of the work has been completed and inspected under permit 1115. Thank you and please let me know if you have any questions, Sincerely, Andy Gray McKinstry Project Superintendent andrewg @mckinstry.com 206.930.4729 bAI., Diet, ORW1NI L' � ,�,,l cal I z� Mn '�jolo �� fGti (�" 13 5005 3rd Avenue South • Seattle, WA 98134 • 206.762.3311 • FAX 206.762.2624 California • Colorado • Idaho • Kansas • Minnesota • Missouri • Montana • Oregon • Texas • Washington • Wisconsin Monday, April 15, 2013 Bob Benedicto, RA Building Official Department of Community Development 6300 Southcenter Boulevard Tukwila, WA 98188 RE: Permit EL12 -0960 and EL12 -1115 City of Tukwila Pool 4414 S 144th St Tukwila, WA 98168 Bob; I recently received a letter from your department stating that Permit EL12 -0960 had not yet received a final inspection and would expire on 5/12/13 unless an inspection was conducted. The ensuing investigation at our end revealed that we, McKinstry, and our Electrical Subcontractor, Betschart Electric, mistakenly acquired overlapping electrical permits for the work done at the City of Tukwila Pool. McKinstry acquired Permit EL12 -0960 to cover a scope of work valued at $12,730.00. This amount was to cover the value of work associated with connections to new fan motors, boiler room equipment and air handling units as well as install a new VFD on the pool circulation pump. It did not include any of the lighting upgrade work as we assumed that would be handled by a separate over - the - counter permit at a later date by the lighting subcontractor. Ultimately however, we subcontracted with Betschart Electric to take care of all the work listed above as well as the lighting upgrade work and they subsequently acquired permit EL12 -1115 to cover the entire scope of work valued at $56,500.00. As it stands now, all of the work (electrical and otherwise) has been completed and all permits have been finalized (including the building permit). As such, will you please close the remaining open permit EL12 -0960. Thank you and please let me know if you have any questions, Sincerely, Andy Gray McKinstry Project Superintendent andrewg @mckinstry.com 206.930.4729 c646 liC4i:v %.:! CITY OF TUKWILA �p APR 5 201 PERMIT CENTER A ►7/2,0/3 - ,`.#41.ethr J -44- go-400044 ,P/ 5005 3rd Avenue South • Seattle, WA 98134 • 206.762.3311 • FAX 206.762.2624 California • Colorado • Idaho • Kansas • Minnesota • Missouri • Montana • Oregon • Texas •Washington • Wisconsin 04 -02 -2013 DAVE ROBINAUGH 5005 THIRD AV S SEATTLE WA 98134 City of Tukwila Department of Community Development RE: Permit No. EL12 -0960 CITY OF TUKWILA - POOL 4414 S 144 ST TUKW Dear Permit Holder: Jim Haggerton, Mcryor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 05/12/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 05/12/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. ELI2 -0960 000 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431 -3670 • Fc[x 206-431-3665 PERMIT CO D COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0960 DATE: 10 -10 -12 PROJECT NAME: CITY OF TUKWILA POOL SITE ADDRESS: 4414 S 144 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: , PG "' 10'41' uilding Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -11 -12 Complete Incomplete Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 -08 -12 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople P -Iter Friendly Page Electrical Contractor A business licensed by LEN to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MCKINSTRY CO LLC 2067623311 Po Box 24567 Seattle WA 98124 King Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602569922 Active MCKINCL942DN Electrical Contractor 3/15/2006 3/15/2014 General Unused Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LYDIGML901JL LYDIG + MCKINSTRY LLC Construction Contractor General Unused 4/13/2010 4/13/2014 Active MCKINC'993QE MCKINSTRY CO Electrical Contractor General Unused 11/5/2001 11/5/2007 Out Of Business Electrical Administrator INFORMATION License WILLIDR93304 Name WILLIAMS, DAVID RAY Status Active Business Owner Information Name Role Effective Date Expiration Date BLACK, STEPHEN Agent 03/15/2006 Bond Amount ALLEN, DEAN CHARLES Partner /Member 06/09/2010 929523050 MOORE, DOUGLAS J Partner /Member 03/15/2006 ALLEN, DAVID Partner /Member 03/15/2006 WESTERN SURETY CO TEPLICKY, JOSEPH W (BILL) Partner /Member 03/15/2006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 Western Surety Co 929523050 03/06/2011 Until Cancelled $4,000.00 02/25/2011 2 WESTERN SURETY CO 929511593 11/16/2010 Until Cancelled $4,000.00 10/06/2010 1 TRAVELERS CAS & SURETY CO 104702041 03/06/2006 Until Cancelled 03/06/2011 $4,000.00 03/15/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information https://fortress.wa.gov/lni/bbip/Print.aspx 11/13/2012 LIGHTING w- I 0 4 a a CM FLUORESCENT FIXTURE, DRAWN TO SCALE ON PLANS- LETTER IN FIXTURE INDICATES SWITCH LEG CONTROL FLUORESCENT STRIP FIXTURE, DRAWN TO SCALE FIXTURE CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE RECESSED WALL MOUNTED BATTERY PACK LIGHTING FIXTURE, WALL WASHER TRACK LIGHT FIXTURE SUPPLIED FROM EMERGENCY CIRCUIT EXIT SIGN - DIRECTIONAL ARROWS AS INDICATED, SHADED SIDES ILLUMINATED LIGHTING STANDARD - FIXTURE(S), POLE & BASE LIGHT FIXTURE TYPE - SEE FIXTURE SCHEDULE SWITCH - SINGLE POLE SUBSCRIPTS a,b, etc., DENOTES CIRCUIT CONTROLLED 3 WAY SWITCH 4 WAY SWITCH SWITCH - KEY OPERATED SWITCH - OCCUPANCY SENSOR SWITCH - WITH PILOT LIGHT $T SWITCH - TIMER DIMMER 16 DIMMER W /OCCUPANCY SENSOR SLY MOMENTARY CONTACT LOW VOLTAGE SWITCH SWITCHBANK ® RELAY - NEC CLASS II LOW VOLTAGE TRANSFORMER 0 OCCUPANCY SENSOR Q SWITCH - PHOTO CELL CIRCUITS A\ RACEWAY CONCEALED IN CEILING OR WALL. HASH MARKS INDICATE NUMBER E OF WIRES. #12 AWG WIRE UNLESS OTHERWISE NOTED. THREE WIRES IF NO HASH MARK SHOWN. LONG HASH MARK DENOTES NEUTRAL. s INDICATES GROUND WIRE. EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. EXISTING RACEWAY (IF HASH MARKS ARE SHOWN, PULL NEW CONDUCTORS) RACEWAY BELOW SLAB OR UNDERGROUND EXPOSED CONDUIT RUN ON SURFACE OF WALL OR CEILING RACEWAY UP RACEWAY DOWN RACEWAY STUB -OUT WITH BUSHING HOME RUN TO PANEL OR LOCATION NOTED CIRCUIT CONTINUATION ® JUNCTION BOX PULL BOX 0 GROUNDING ROD VICINITY MAP LEGAL DESCRIPTION W 190 FT OF E 565 FT OF S 320 FT OF SW 1/4 OF SE 1/4 LESS CO RD PROJECT LOCATION RECEPTACLES I SINGLE RECEPTACLE 120V 4h DUPLEX RECEPTACLE 120V DUPLEX RECEPTACLE 120V, MOUNTED 3" ABOVE COUNTER BACKSPLASH DOUBLE DUPLEX RECEPTACLE 120V 40 DOUBLE DUPLEX RECEPTACLE 120V, MOUNTED 3" ABOVE COUNTER BACKSPLASH DUPLEX RECEPTACLE 120V, EMERGENCY CIRCUIT DOUBLE DUPLEX RECEPTACLE 120V, EMERGENCY CIRCUIT .4 SPLIT WIRED RECEPTACLE, 120V, TOP SWITCHED ▪ COMBINATION RECEPTACLE 120/208V, 120/240V . SPECIAL RECEPTACLE, SEE PLANS FOR ADDITIONAL INFORMATION FLUSH FLOOR OUTLET (DEVICES AS INDICATED) FLOOR OUTLET - POKE THROUGH (DEVICES AS INDICATED) la TELEPHONE / POWER POLE MULTI - OUTLET ASSEMBLY - LENGTH PER PLAN, DEVICE(S) AS INDICATED COMBINATION OUTLET (DEVICES AS INDICATED) DUPLEX RECEPTACLE - SURGE PROTECTOR TYPE DUPLEX RECEPTACLE - ISOLATED GROUND TYPE DUPLEX RECEPTACLE - SAFETY TYPE DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE C�7 CONTROL FUSED DISCONNECT SWITCH (FUSE RATING INDICATED) D DISCONNECT SWITCH MOTOR STARTER - MAGNETIC ES MANUAL STARTER ®+ COMBINATION MOTOR STARTER DISCONNECT SWITCH ® ENCLOSED CIRCUIT BREAKER ® THERMOSTAT ® TIME CLOCK CONTACTOR ® RELAY - CONTROL TYPE O PHOTOCELL CONTROL 8 PUSH BUTTON CONTROL STATION H AUTO DOOR PUSHPLATE EQUIPMENT • ;. PANEL - 208 VOLT SYSTEM PANEL - 480 VOLT SYSTEM EQUIPMENT CONNECTION MOTOR CONNECTION SINGLE PHASE MOTOR CONNECTION 3 PHASE TRANSFORMER TRANSIENT VOLTAGE SURGE SUPPRESSOR REVISIONS No changes shall be made to the scope of wcrk without prior approval of Tukwila Buildiog Division. NOTE: E: Revisions will rsailre a new plan submittal and may include additional plan review fees. j ELECTRICAL RISER -.'''f'- FUSED SWITCH —C-11— CIRCUIT BREAKER DRAWOUT CIRCUIT BREAKER CIRCUIT BREAKER - GROUND FAULT PROTECTION CABLE TO BUS CONNECTION FUSE OR CURRENT UMITER GROUND CONNECTION IDENTIFICATION SYMBOL FOR FEEDER SIZES TRANSFORMER WATT -HOUR METER OA AMMETER O VOLTMETER TRANSFER SWITCH O ENGINE - GENERATOR XXXX > AVAILABLE SHORT CIRCUIT CURRENT GENERAL INFORMATION SYMBOLS SPECIAL OUTLET HEIGHTS ARE SHOWN ON THE ELECTRICAL DRAWINGS OR ON THE ARCHITECTURAL DRAWINGS. IF SPECIAL OUTLET HEIGHTS ARE NOT SHOWN OR REQUIRED, THEN LOCATE OUTLETS AS NOTED BELOW. OUTLET HEIGHTS ARE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE OF THE OUTLET UNLESS NOTED OTHERWISE. XO KEY NOTE © REVISION SYMBOL UGHT SWITCHES POINT OF CONNECTION c POINT OF DEMOLITION C�' ® UGHT UNE INDICATES EXISTING DEVICES EXISTING ELECTRICAL x x x x . REMOVE EQUIPMENT NEC CODE REQUIRED CLEAR WORKING SPACE 54 INCHES VERTICALLY MOUNTED X EQUIPMENT DESIGNATION X ELECTRICAL INFORMATION X © EQUIPMENT DISCONNECT AD -AMP DISCONNECT AF -AMP FUSES DETAIL OR DIAGRAM NUMBER © SHEET NUMBER WHERE DETAIL /DIAGRAM SHOWN ; . SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN X PLAN NUMBER X SHEET NUMBER WHERE, PLAN SHOWN © REVISION NUMBER - DENOTES NUMBER OCCURED le° AND DATE WHEN REVISION OR ISSUE REVISION CLOUD - DENOTES AREA OF CHANGE Ark r- - - - -1 © DETAIL REFERENCE OUTLINE WITH NUMBER AND SHEET LOCATION DRAWING INDEX SHEET N0. SHEET TITLE E0.0 ELECTRICAL LEGEND ED2.0 FLOOR PLAN - ELECTRICAL DEMO E2.0 FLOOR PLAN - ELECTRICAL E2.1 ROOF PLAN - ELECTRICAL E3.0 ENLARGED BOILER ROOM ELECTRICAL PLANS E3.2 ENLARGED AIR HANDLER MECHANICAL ROOM ELECTRICAL PLANS E5.0 PANEL P DETAIL E7.0 MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULE & EST. LOAD SUMMARY SEPARATE PERMIT REQUIRED FOR: ti 'foal Ci Electrical Plumbing Q'Cas Piping City of Tukwila BUILDING DIVISION ABBREVIATIONS ACH ABOVE COUNTER HEIGHT AFF ABOVE FINISHED FLOOR AG ABOVE GRADE AHJ AUTHORITY HAVING JURISDICTION A, AMP AMPERE ATR ALL THREAD ROD ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE CB CIRCUIT BREAKER CKT CIRCUIT CTB COMMUNICATIONS TERMINAL BOARD DED DEDICATED DTT DRY TYPE TRANSFORMER DW DISHWASHER E EXISTING, (E) EXISTING EA EACH EC ELECTRICAL CONTRACTOR EWC ELECTRIC WATER COOLER FA FIRE ALARM FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FI FILM ILLUMINATOR G, GND GROUND GD GARBAGE DISPOSAL GFEP GROUND FAULT EQUIPMENT PROTECTION GR, GFCI GROUND FAULT CIRCUIT INTERRUPTER GEN GENERATOR HP HORSEPOWER IG ISOLATED GROUND IH INSTA -HOT WATER DISPENSER J -BOX JUNCTION BOX MC MCC MCB MEZZ MLO MW N NEC NIC 0 PNL PSE R RO RECEPT REF SCH SCL SPECS SW SWBD TELE TSP TYP V VFD VP W WC WP XFMR MECHANICAL CONTRACTOR MOTOR CONTROL CENTER MAIN CIRCUIT BOARD MEZZANINE MAIN LUG OUT MICROWAVE NEUTRAL NATIONAL ELECTRICAL CODE NOT IN CONTRACT PHASE PANEL PUGET SOUND ENERGY RACEWAY RACEWAY ONLY RECEPTACLE REFRIGERATOR SCHEDULE SEATTLE CftY LIGHT SPECIFICATIONS SWITCH SWITCHBOARD TELEPHONE TWISTED SHIELDED PAIR TYPICAL VOLT VARIABLE FREQUENCY DRIVE VANDALPROOF WATT WARMING CABINET WEATHERPROOF TRANSFORMER FILE. COPY Permit No. L D 111 ^-1 rrvi3w approval is subOol to errors and omissiors. of construction documents does nct authc t.3 Jlai �Cfl Of any adopted code or ©rdinanc A; kpprOv3a w Cgpy ',r' conditions is acknowledg : By Date: GENERAL NOTES 1. COMPLY WITH NATIONAL ELECTRICAL CODE LATEST ADOPTED EDITION AND WAC 296 -46B. 2. SYMBOLS ARE BASED ON A STANDARD PACKAGE PER CATEGORY. NOT ALL SYMBOLS MAY APPEAR ON DRAWINGS. 3. THE LOCATIONS OF ELECTRICAL DEVICES OR LIGHTING FIXTURES INDICATED, ON MECHANICAL PLANS ELEVATIONS OR SECTIONS TAKE PRECEDENCE OVER LOCATIONS INDICATED ON THE ELECTRICAL DRAWINGS. 4. COORDINATE WORK WITH THAT OF ALL CONTRACTORS AND /OR OTHER TRADES DOING WORK ON THE PROJECT. EXAMINE ALL DRAWINGS AND SPECIFICATIONS .9F OTHER TRADES FOR CONSTRUCTION DETAILS AND COORDINATION. 5. OBTAIN AND REVIEW ALL SUBMITTALS AND SHOP DRAWINGS OF EQUIPMENT WITH ELECTRICAL CONNECTIONS. OBTAIN AND REVIEW ALL SUBMITTALS AND SHOP DRAWINGS OF EQUIPMENT WITH ELECTRICAL CONNECTIONS FURNISHED UNDER OTHER DMSIONS OF THE SPECIFICTION AND BY THE OWNER. PROVIDE ALL WIRING IN ACCORDANCE WITH SPECIFIC EQUIPMENT REQUIREMENTS. IMMEDIATELY ADVISE THE ENGINEER OF ANY CHANGES WHICH MAY EFFECT THE CONTRACT. 6. FUSED DISCONNECT SWITCHES SHALL NOT BE REMOVED FROM THIS INSTALLATION WITHOUT FIRST CONFIRMING THE AIC RATINGS AT THAT CONNECTION POINT IN THE SYSTEM AND CONFIRMING THAT ALL DEVICES IN THE SYSTEM MEET OR EXCEED THE AVAILABLE AIC FAULT CURRENT. CALCULATIONS SHALL BE TAKEN DOWN TO 4,000 AIC. 7. THE DRAWINGS AND SPECIFICATIONS ARE COMPUMENTARY AND WHAT IS CALLED FOR (OR SHOWN) IN EITHER IS REQUIRED TO BE PROVIDED AS IF CALLED FOR IN BOTH. AS -BUILT REQUIREMENTS 1. MCKINSTRY ELECTRICAL CONTRACTOR SHALL PRODUCE ACCURATE AS -BUILT DRAWINGS AND PANEL SCHEDULES REFLECTING CHANGES DEVIATING FROM CONSTRUCTION DOCUMENTS. 2. AS -BUILT DRAWIINGS SHALL BE RETURNED TO MCKINSTRY ENGINEERING WHEN COMPLETED. OUTLET MOUNTING HEIGHTS SPECIAL OUTLET HEIGHTS ARE SHOWN ON THE ELECTRICAL DRAWINGS OR ON THE ARCHITECTURAL DRAWINGS. IF SPECIAL OUTLET HEIGHTS ARE NOT SHOWN OR REQUIRED, THEN LOCATE OUTLETS AS NOTED BELOW. OUTLET HEIGHTS ARE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE OF THE OUTLET UNLESS NOTED OTHERWISE. RECEPTACLES 18 INCHES VERTICALLY MOUNTED UGHT SWITCHES 48 INCHES VERTICALLY MOUNTED PANELBOARDS 72 INCHES TO TOP OF PANELBOARD TELEPHONE OUTLET - DESK 18 INCHES VERTICALLY MOUNTED TELEPHONE OUTLET - WALL 54 INCHES VERTICALLY MOUNTED COMPUTER OUTLET - DESK 18 INCHES VERTICALLY MOUNTED ' env ZO t Z (Q� Cit r Of Tukwila BU L;; isms DIV' REVIEWED FOR COMPL IANCE WITH NFPA 70 NEC OCT 18 2012 City of ; ila BUILDING - ISION RECEIVED CITY OF TUKWILA OCT 1 0 2012 PERMIT CENTER L11 09160 PERMIT DRAWINGS PROJECT: instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 7331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: TRACK POOL \ REVISIONS: 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING ANNE GOERLICH ANNE GOERLICH DENNIS NISSEN C10256 9/26/12 AS SHOWN ELECTRICAL LEGEND SHEET NUMBER: E0.0 XL 4�1� WOMEN'S LOCKER ROOM WOMEN'S STAFF ENTRY MANAGER MEN'S LOCKER ROOM MEN'S STAFF X FIRST AID FORAGE Sc JANITOR MECHANICAL ROOM NATATORIUM (MO REVIEWED FOR COMPLIANCE WITH NFPA 7O - NEC OCT 18 2012 City of Tukwila BUILDING DIVISION (E)M -2 PNL B ELOI3 CIRC#31,33,35 CIRCC32,34.36 LOCKER ROOM SUPPLY FAN ( )PNL —B N D'_0„ LOCKER ROOM RETURN FAN FLOOR PLAN - ELECTRICAL DEMO • SCALE: 1/8" = 1' -0" 0 4' 8' 16' cel KEY NOTES 0 EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. DISCONNECT POWER FROM UNIT AND REMOVE EXISTING DISCONNECT SWITCH, STARTER AND 20A 3- POLE CIRCUIT BREAKER. RETAIN CONDUIT AND PHASE CONDUCTORS FOR REUSE. REMOVE EXISTING GROUND CONDUCTOR BACK TO SOURCE. ® EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. DISCONNECT POWER FROM UNIT AND REMOVE EXISTING DISCONNECT SWITCH, STARTER AND 30A 3 —POLE CIRCUIT BREAKER. RETAIN CONDUIT AND CONDUCTORS FOR REUSE. RECEIVED CITY OF TUKWILA OCT 10 2012 PERMIT CENTER PERMIT DRAWINGS PROJECT: For Th instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1 -800- 669 -6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503- 331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: REVISIONS: 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING ANNE GOERLICH ANNE GOERLICH DENNIS NISSEN C10256 9/26/12 AS SHOWN FLOOR PLAN - ELECTRICAL DEMO SHEET NUMBER: ED2IO 11 ENTRY 1 1 1 WOMEN'S LOCKER ROOM ATTENDANT WOMEN'S STAFF MEN'S LOCKER ROOM MANAGER MEN'S STAFF I MECHANICAL ROOM NATATORIUM REVIEWED FOH COMPLIANCE WITH NFPA 70 - NEC OCT 1 8 2012 City of Tukvvila BUILDING DIVISION ORAGE & JANITOR (N)M-2 IC> LOCKER ROOM SUPPLY FAN PNL B ELE 421.3 CIRC#31,33 CIRC#32,34,36 0 (E)PNL—B N C-0" LOCKER ROOM RETURN FAN 350 1 • FLOOR PLAN - ELECTRICAL SCALE: 1/81' = 1'-0* 0 4' 8' 16' KEY NOTES 0 NEW EQUIPMENT TO REPLACE EXISTING EQUIPMENT IN THE SAME LOCATION. O WIRE NEW EQUIPMENT PER MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULE. 0 PROVIDE AND INSTALL NEW 35A 3—POLE CIRCUIT BREAKER IN PANEL B CIRCUITS 1132,34,36 FOR LOCKER ROOM SUPPLY FAN MOTOR (N)M-1. O PROVIDE AND INSTALL NEW 20A 3—POLE CIRCUIT BREAKER IN PANEL B CIRCUITS 1131,33,35 FOR LOCKER ROOM EXHAUST FAN MOTOR (N)M-2. ® MC TO PROVIDE MOTOR STARTER. EC TO INSTALL MOTOR STARTER. e(1 tLIT 04t411.) 1 RECEIVED CITY OF TUKWILA OCT 1 0 2012 PERMIT CENTER PERMIT DRAWINGS For Th instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEAMS, WA 98124 1-800-669-6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503-331-0234 www.rn ckin stry.com PROJECT: TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT POOL TRACK REGISTRATION: of W sk,e1,A, AL".°..v 415s5T6E0oyiovs2.4444, REVISIONS: 9/26/12 90% CD'S 10/8/12 PERMIT DRAWHGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING ANNE GOERLICH ANNE GOERLICH DE\NIS NISSEN C10256 9/26/12 AS SHOWN FLOOR PLAN - ELECTRICAL SHEET NUMBER: E2.0 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC OCT 18 2012 City of Tukwila BUILDING DIVISION MECHANICAL ROOM EXHAUST FAN ■ EF -1 ROOF PLAN - ELECTRICAL SCALE: 1 /8" = 1' -0" 0 4' 8' 16' KEY NOTES 0 ADD ALTERNATE: PROVIDE THE ELECTRICAL CONNECTION TO A REPLACEMENT MECHANICAL ROOM EXHAUST FAN. 09(00 RECEIVED CITY OF TUKWILA OCT 10 2012 PERMIT CENTER PERMIT DRAWINGS PROJECT: For Th instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 - 331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: TRACK Poop � REVISIONS: 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING ANNE GOERLICH ANNE GOERLICH DENNIS NISSEN C10256 9/26/12 AS SHOWN ROOF PLAN - ELECTRICAL SHEET NUMBER: E2.1 KN)CCP -11 DEMOLITION KEY NOTES O EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. DISCONNECT POWER FROM UNIT AND REMOVE EXISTING MOTOR RATED SWITCH. RETAIN CONDUIT AND CONDUCTORS FOR REUSE. • EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. DISCONNECT POWER FROM UNIT AND REMOVE DOSING DISCONNECT SWITCH. RETAIN CONDUIT AND CONDUCTORS FOR REUSE 0 EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. DISCONNECT POWER FROM UNIT AND REMOVE EXISTING STARTER LOCATED IN PANEL P. RETAIN CONDUIT AND CONDUCTORS FOR REUSE. O EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. DISCONNECT POWER FROM UNIT AND REMOVE EXISTING STARTER AND 20A 3—POLE CIRCUIT BREAKER IN PANEL C CIRCUITS 1111_ 3335. RETAIN CONDUIT AND PHASE CONDUCTORS FOR REUSE. TING GROUND CONDUCTOR BACK TO SOURCE. ® EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. DISCONNECT POWER FROM UNIT AND REMOVE EXISTING STARTER. REMOVE EXIS11NG CONDUIT AND CONDUCTORS BACK 10 SOURCE, PANEL P. -► MAIN SWBD, HANDLE #5 (E)CONTROL PANEL P X X X X X X X X X X X PNL C CIRC#26,28,30 VIA CONTACTOR UNIT FOR 'THE BOILER AND DWH TANK PNL C CIRC#31,33,35 BOILER AND DHW CONTACTOR (E)PNL —C PNL P 15A CB VIA STARTER IN PNL P PNL C CIRC#9 • x L_ PNL C CIRC#19 VIA CONTACTOR UNIT FOR THE BOILER AND DWH TANK BOILER ROOM ELECTRICAL DEMO PLAN SCALE: 1/4' = 1' -0" KEY NOTES O NEW EQUIPMENT TO REPLACE EXISTING EQUIPMENT IN THE SAME LOCATION. ® WIRE NEW EQUIPMENT PER MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULE. ® PROVIDE AND INSTALL NEW 15A CIRCUIT BREAKER IN PANEL C CIRCUIT #B FOR PUMP (N)P -4. ® MC TO PROVIDE MOTOR STARTER. EC TO INSTALL MOTOR STARTER. ® LOCATE STARTER IN PANEL P. © NOT USED. O EXTEND CONDUIT AND CONDUCTORS AS NEEDED TO REACH (N)DWH -1. ® PROVIDE AND INSTALL NEW 35A 3 —POLE CIRCUIT BREAKER IN PANEL C CIRCUITS #31,33,35 FOR PUMP (N)P -1. ® LOCATE RECEPTACLE APPROXIMATELY 52" AFT. RECEPTACLE TO SERVE NEW POOL CHEMISTRY PUMP. 2 E5.0 - - MAIN SWBD. HANDLE #5 (E)CONTROL PANEL PJ (N)P -5 PNL C CIRC #5,7 PNL C CIRC#9 --w- OPNL C CIRC#8 DM �,Q d t4ttsI� (N)P -1. 00 00 (N)B -1 00 ©0 ® N P -3 00 (N)P -4 BOILER AND DHW CONTACTOR ff E PNL -C PNL P 15A CB VIA STARTER IN PNL P PNL C CIRC #26,28,30 VIA CONTACTOR UNIT FOR THE BOILER AND DWH TANK PNL C CIRC#31,33,35 PNL C CIRC #19 VIA CONTACTOR UNIT FOR THE BOILER AND DWH TANK BOILER ROOM ELECTRICAL PLAN SCALE: 1/4" = REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC OCT 18 2012 City of Tukwila BUILDING DIVISION_ RECEIVED CITY OF TUKWILA OCT 10 2012 PERMIT CENTER PERMIT DRAWINGS For Th PROJECT: instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 - 331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: REVISIONS: 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING ANNE GOERLICH ANNE GOERLICH DENNIS NISSEN C10256 9/26/12 AS SHOWN ENLARGED BOILER ROOM ELECTRICAL PLANS SHEET NUMBER: E3.0 • PNL C CIRCj38,40,42 VIA STARTER AIR HANDLER MECHANICAL ROOM ELECTRICAL DEMO PLAN CD SCALE: 1/4" = 1' -0" DEMOLITION KEY NOTES 0 EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. DISCONNECT POWER FROM UNIT AND REMOVE EXISTING DISCONNECT SWITCH AND STARTER. REMOVE CONDUIT BACK TO SOURCE. RETAIN PHASE CONDUCTORS FOR REUSE IF THEY ARE 4 OR LARGER GAGE RETAIN GROUND CONDUCTOR FOR REUSE IF 18 OR LARGER GAGE. EXISTING PHASE CONDUCTORS ARE ESTIMATED TO BE #3 MID EXISTING GROUND CONDUCTOR IS ESTIMATED TO BE IB. LADDER L (N)SF -1 00 c PNL C CIRC #38,40,42 C LJ EO —O AIR HANDLER MECHANICAL ROOM ELECTRICAL PLAN SCALE: 1/4* = 1' -0" KEY NOTES 0 NEW EQUIPMENT TO REPLACE EXISTING EQUIPMENT IN THE SAME LOCATION. ® WIRE NEW EQUIPMENT PER MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULE. 03 EC TO PROVIDE AND INSTALL 1 Y" CONDUIT FROM (N)SF -1 TO SOURCE. ROUTE ALONG SAME PATH AS DEMOED 'CONDUIT. REVIEWED .FO COMPLIANCE ®C N WITH NF OCT 18 2012 City of Tukwila BUILDING DIVISION' CfictU e4 '9\4) RECEIVED CITY OF TUKWILA OCT 10 2012 PERMIT CENTER PERMIT DRAWINGS PROJECT: For Th instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 - 331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: TRACK POOL .' REVISIONS: 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING ANNE GOERLICH ANNE GOERLICH DENNIS NISSEN C10256 9/26/12 AS SHOWN SHEET TITLE: ENLARGED AIR HANDLER MECHANICAL ROOM ELECTRICAL PLANS SHEET NUMBER: E3.2 DEMOLITION KEY NOTES 01 EXISTING CIRCUIT BREAKER TO BE REMOVED. 02 EXISTING STARTER TO BE REMOVED. ® REMOVE EXISTING CONDUCTORS. ® REMOVE EXISTING CONDUIT. ® REMOVE EXISTING CONDUCTORS BACK TO SOURCE, MAIN SWITCHBOARD HANDLE ,5 DISCONNECT. REMOVE 100A FUSES AT THE HANDLE /5 TO P -5, POOL CIRCULATION PUMP 3 (E)(3)#E 30A/1 P CB 15A/3P 3 (E)(3)#4 — (E)(3)#12 �- (E)(3)#4 (E)(3)#6 SQUARE D LOAD CENTER 20A 15A 15A 15A 20A (E)(3) #12 P-1 POOL ^ CIRCUL/11ION x PUMP, x MOTOR 2 STARTER O x (E)(3) #2O TO P -2, POOL HEATING PUMP - TO MAIN SWBD HANDLE #5O PANEL P DEMOLITION WORK SCALE: NOT TO SCALE KEY NOTES 01 MC TO PROVIDE MOTOR STARTER. EC TO INSTALL MOTOR STARTER. 0 INCREASE FUSE SIZE FOR MAIN SWITCHBOARD HANDLE #5 DISCONNECT, LOCATED IN THE ELECTRICAL ROOM, TO 125A. ® INSTALL CONDUCTORS BACK TO SOURCE, MAIN SWITCHBOARD HANDLE #5 DISCONNECT, PER THE MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULE. ® EC TO PROVIDE AND INSTALL NEW CIRCUIT BREAKER. (N)2 "C W/ ocA4i0 TO P -5, POOL CIRCULATION PUMP (N)(3) #1,(N)(1)#4G 30A/1P CB 15A/3P CB (E)(3)#6 (E)(3) #12 (N)(3) #1, (N)(1)#4G REVIEWED r)H COMPLIANCE WIT NFPA 70 NEC OCT 1 8 2012 City of Tukwila BUILDING DIVISIOK (N)(3)#1,(N)(1)#40 (N)2 "C W /—J (N)(3) #1,(N)(1)#4G SQUARE D LOAD CENTER 20A 15A 15A 15A 20A (E)(3) #12 PANEL P NEW WORK TO P -2, POOL HEATING PUMP TO MAIN SWBD HANDLE #5 SCALE: NOT TO SCALE RECEIVED CITY OF TUKWI A OCT 1 0 2012 PERMIT CENTER PERMIT DRAWINGS PROJECT: For Th instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 - 331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: POOL REVISIONS: 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING ANNE GOERLICH ANNE GOERLICH DENNIS NISSEN C10256 9/26/12 AS SHOWN SHEET TITLE: PANEL P DETAIL SHEET NUMBER: E5.0 SCHEDULE GENERAL NOTES: A ELECTRICAL CONTRACTOR TO PROVIDE LABEL ON INSIDE OF DISCONNECT SWITCH WHICH READS: "REPLACEMENT FUSES ARE TO BE DUAL ELEMENT CURRENT LIMITING AND ARE TO BE PROVIDED WITH THE AIC RATING ABOVE THE AVAILABLE AT THAT POINT IN THE SYSTEM." B. FUSED DISCONNECT SWITCHES SHALL NOT BE REMOVED FROM THIS INSTALLATION WITHOUT FIRST CONFIRMING THE AIC RATINGS AT THAT CONNECTION POINT IN THE SYSTEM AND CONFIRMING THAT ALL DEVICES IN THE SYSTEM MEET OR EXCEED THE AVAILABLE AIC FAULT CURRENT. CALCULATIONS SHALL BE TAKEN DOWN TO 4,000 AIC. SCHEDULE NOTES: 1. CONFIRM ELECTRICAL REQUIREMENTS WTH EQUIPMENT MANUFACTURER PRIOR TO ROUGH -IN 2. EC TO PROVIDE DIRECT CONNECTION TO MECHANICAL PROVIDED VFD. 3. ELECTRICAL TO PROVIDE DIRECT CONNECTION TO IGNITOR. ESTIMATED LOAD SUMMARY NOTE: ESTIMATED LOADS ARE BASED ON UTILITY SUPPLIED PEAK DEMAND, NAMPLATE DATA FOR EXISTING EQUIPMENT REMOVED AND MANUFACTURER SUPPLIED CUT SHEETS ON NEW EQUIPMENT. MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULE EQUIPMENT NUMBER DESCRIPTION ELECTRICAL CHARACTERISTICS CONNECTION STARTER ELECTRICAL FEEDER 21.5 KVA 2.8 KVA 4.9 KVA 2.7 KVA 0.7 KVA 6.1 KVA 0.028 KVA 0.028 KVA 27.1 KVA 2.7 KVA 1.5 KVA NOTES HP kW FLA MCA VOLTAGE PHASE TYPE SIZE FUSE PROVIDED BY PROVIDED BY CONDUIT PH N GND PANEL AND POSITIONS (E)SF -1 POOL SUPPLY FAN 15 11 38.8 208 3 DS 100 1" #3 (EST) #8 (EST) PANEL C, CIRC #38,40,42 (100A CB) REMOVE (E)B -1 GAS BURNER 208 3 DS 30 1" #12 #12 PANEL C, CIRC #26,28,30 (20A CB) VIA BOILER UNIT CONTACTOR REMOVE (E)M -1 LOCKER ROOM SUPPLY FAN MOTOR 5 77 21:5 208 3 DS 30 1/2" #12 #12 PANEL B, CIRC #32,34,36 (20A CB) REMOVE (E)M -2 LOCKER ROOM EXHAUST FAN MOTOR 2 2.2 6 208 3 DS 30 1/2" #12 #12 PANEL B, CIRC #31,33,35 (30A CB) REMOVE (E)HWT -3 DOMESTIC WATER HEATER 1/3 1.2 10 115 1 MRS 3/4" #12 #12 #12 PANEL C, CIRC #19 (20A CB) VIA BOILER UNIT CONTACTOR REMOVE (E)P -1 BUILDING HEATING WATER LOOP PUMP 5 55 152 208 3 3/4" #12 #12 PANEL C, CIRC #31,33,35 (20A CB) REMOVE (E)P -3 DHW CIRCULATION PUMP P -3 1/25 0.1 0.84 115 1 MRS 3/4" #12 #12 #12 PANEL C, CIRC #9 (15A CB) REMOVE (E)P -5 POOL CIRCULATION PUMP 20 19.9 575 200 3 2 " #4 PANEL P, 100A CB VIA 60A CB. REMOVE FED FROM MAIN SWBD, HANDLE #5 (100A FUSES). (E)P -2 POOL HEATING PUMP 2 1.5 6 208 3 1" #12 #12 PANEL P, 100A CB VIA 15A CB. REMOVE. FED FROM MAIN SWBD, HANDLE #5 (100A FUSES). (E)CCP -1 CHEMISTRY CONTROLLER 120 1 120VAC RECEPTACLE REMOVE (N)SF -1 POOL SUPPLY FAN 20 21.5 59.7 208 3 VFD MC MC 1 114" #3 #8 PANEL C, CIRC #38,40,42 (100A CB) _ REPLACES EXISTING (N)B -1 GAS BURNER 3 2.8 7.8 208 3 FDS 15 EC 1" #12 #12 PANEL C, CIRC #26,28,30 (20ACB) REPLACES EXISTING (N)M -1 LOCKER ROOM SUPPLY FAN MOTOR 5 4.9 13.7 208 3 FDS 25 EC MC 1/2" #12 #10 PANEL B, CIRC #32,34,36 (35ACB) REPLACES EXISTING (N)M -2 LOCKER ROOM EXHAUST FAN MOTOR 2 2.7 7.5 208 3 FDS 15 EC MC 1/2" #12 #12 PANEL B, CIRC #31,33,35 (20ACB) REPLACES EXISTING (N)DWH -1 DOMESTIC WATER HEATER 0.74 6.2 120 1 MRS EC 3/4" #12 #12 #12 PANEL C, CIRC #19 (20ACB) VIA BOILER UNIT CONTACTOR REPLACES EXISTING (N)P -1 BUILDING HEATING WATER LOOP PUMP 5 6.1 16.8 208 3 EC MC 3/4" #12 #10 PANEL C, CIRC #31,33,35 (35ACB) REPLACES EXISTING (N)P -3 DWH CIRCULATION PUMP P -3 0.028 0.23 120 1 MRS EC 3/4" #12 #12 #12 PANEL C, CIRC #9 (15ACB) REPLACES EXISTING (N)P -4 DWH CIRCULATION PUMP P -4 0.028 0.23 120 1 MRS EC 3/4" #12 #12 #12 PANEL C, CIRC #8 (15ACB) NEW (N) P -5 POOL CIRCULATION PUMP 25 27.1 75.2 208 3 VFD MC MC 1" #1 :#4 PANEL P, 125ACB VIAVFD. REPLACES EXISTING. UPGRADE MAIN SWBD, HANDLE #5 100AFUSES TO 125AFUSES. (N)P -2 POOL HEATING PUMP 2 2.7 7.5 208 3 EC MC 1" #12 #12 PANEL P, 125ACB VIA 15ACB. REPLACES EXISTING. UPGRADE MAIN SWBD, HANDLE #5 100A FUSES TO 125A FUSES. (N)CCP -1 CHEMISTRY CONTROLLER 1.4 1225 115 1 EC 314" #12 #12 #12 PANEL C, CIRC #7 (20ACB) REPLACES EXISTING SCHEDULE GENERAL NOTES: A ELECTRICAL CONTRACTOR TO PROVIDE LABEL ON INSIDE OF DISCONNECT SWITCH WHICH READS: "REPLACEMENT FUSES ARE TO BE DUAL ELEMENT CURRENT LIMITING AND ARE TO BE PROVIDED WITH THE AIC RATING ABOVE THE AVAILABLE AT THAT POINT IN THE SYSTEM." B. FUSED DISCONNECT SWITCHES SHALL NOT BE REMOVED FROM THIS INSTALLATION WITHOUT FIRST CONFIRMING THE AIC RATINGS AT THAT CONNECTION POINT IN THE SYSTEM AND CONFIRMING THAT ALL DEVICES IN THE SYSTEM MEET OR EXCEED THE AVAILABLE AIC FAULT CURRENT. CALCULATIONS SHALL BE TAKEN DOWN TO 4,000 AIC. SCHEDULE NOTES: 1. CONFIRM ELECTRICAL REQUIREMENTS WTH EQUIPMENT MANUFACTURER PRIOR TO ROUGH -IN 2. EC TO PROVIDE DIRECT CONNECTION TO MECHANICAL PROVIDED VFD. 3. ELECTRICAL TO PROVIDE DIRECT CONNECTION TO IGNITOR. ESTIMATED LOAD SUMMARY NOTE: ESTIMATED LOADS ARE BASED ON UTILITY SUPPLIED PEAK DEMAND, NAMPLATE DATA FOR EXISTING EQUIPMENT REMOVED AND MANUFACTURER SUPPLIED CUT SHEETS ON NEW EQUIPMENT. SYSTEM VOLTAGE SERVICE RATING 80% SERVICE RATING 208 V /3PH 600 A 480 A EXISTING PEAK DEMAND May -2011 0.9 PF (Est.) 125% ADJUSTMENT FACTOR 50 KW 55.6 KVA 69.4 KVA EQUIPMENT ADDED (N)SF -1 59.7 FLA 208V /3PH (N)B -1 7.8 FLA 208V /3PH (N)M -1 13.7 FLA 208V /3PH (N)M -2 7.5 FLA 208V /3PH (N)HWT -3 6.2 FLA 120V /1PH (N)P -1 16.8 FLA 208V /3PH (N)P -3 0:23 FLA 120V /1PH (N)P -4 0.23 FLA 120V /1PH (N) P -5 75.2 FLA 208V /3PH (N)P -2 7.5 FLA 208V /3PH (N)CCP -1 12.25 FLA 115V/1PH 21.5 KVA 2.8 KVA 4.9 KVA 2.7 KVA 0.7 KVA 6.1 KVA 0.028 KVA 0.028 KVA 27.1 KVA 2.7 KVA 1.5 KVA TOTAL LOAD ADDED ESTIMATED NEW BUILDING LOAD (PEAK DEMAND + LOAD ADDED) 70.1 KVA 139.5 KVA 387.3 A @ 208 V /3PH LEGEND: FDS - FUSED DISCONNECT SWITCH VFD - VARIABLE FREQUENCY DRIVE (FURNISHED BY DIV. 15 AND INSTALLED BY DIV. 16) DS - DISCONNECT SWITCH MRS - MOTOR RATED SWITCH (20 AMP RATING UNLESS NOTED OTHERWISE.) DC - DIRECT SINGLE POINT CONNECTION TO UNIT POWER BOX CMS - COMINATION MAGNETIC MOTOR STARTER WITH FUSED DISCONNECT SWITCH. T - TOGGLE SWITCH (E) EXISTING (N) NEW REIEWtli rL MLIANCE WITH PA 70 - NEC CT182012 of Tukwila DING DIVIG' Cfi'(' ciA ( P4 04 fis113 1 - o9p RECEIVED CITY OF TUKWILA OCT 10 2012 PERMIT CENTER PERMIT DRAWINGS PROJECT: For Th instry. iie Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503- 331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: REVISIONS: 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING ANNE GOERLICH ANNE GOERLICH DENNIS NISSEN C10256 9/26/12 AS SHOWN MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULE & EST. LOAD SUMMARY SHEET NUMBER: E7.0