Loading...
HomeMy WebLinkAboutPermit EL12-0998 - WOWRACK TECHNOLOGIESWOW TECHNOLOGIES 12201 TUKWILA INTERNATIONAL BL EL1 2-0998 City oikukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No.: 0923049120 Permit Number: EL12 -0998 Address: 12201 TIIKWILA INTERNATIONAL BL TUKW Issue Date: 11/05/2012 Permit Expires On: 05/04/2013 Project Name: WOW TECHNOLOGIES Owner: Name: INTERNATIONAL GATEWAY WEST Address: 12201 TUKVVILA INTERNATIONAL BLVD , SEATTLE WA 98168 Contact Person: Name: TODD SEARS Address: 3623 EAST MARGINAL WY S , SEATTLE WA, 98134 Contractor: Name: EVERGREEN POWER SYSTEMS INC Address: 3623 EAST MARGINAL WY S , SEATTLE WA 98134 Contractor License No: EVERGPS950BE Phone: 206 - 510 -5167 Phone: 206 774 -1400 Expiration Date: 01/05/2013 DESCRIPTION OF WORK: FURNISH AND INSTALL (1) 100A 480/277V PANEL, (1) 100A MCB 208/120V PANEL, (1) 30 KVA TRANSFORMER Value of Electrical: NRES: $7,500.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: Q $287.63 2008 Date: l I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: PQJ( � Date: it/-3 12 Print Name: D cA - ; c k Sea,- S This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL1 2-0998 Printed: 11 -05 -2012 PERMIT CONDITIONS • Permit No. EL12 -0998 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -0998 Printed: 11 -05 -2012 CITY OF TUKWA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Electrical Permit No. -L Project No. Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: 12201 TUKWILA INTERNATIONAL BLVD Suite Number: Floor: WOWRACK TECHNOLOGIES New Tenant: ❑ Yes m.. No PROPERTY OWNER Name: SABEY CORPORATION Address: 12201 TUKWILA- INTERNATIONAL BLV City: SEATTLE State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: TODD SEARS Address: 3623 EAST MARGINAL WAY SOUTH City: SEATTLE State: WA Zip: 98134 Phone: (206) 510 -5167 Fax: (206) 774 -1401 Email: tsear @evergreenps.net ELECTRICAL CONTRACTOR INFORMATION Company Name: EVERGREEN POWER SYSTEMS, 1 Address: 3623 EAST MARGINAL WAY SOUTH City: SEATTLE State: WA Zip: 98134 Phone: (206) 774 -1400 Fax: (206) 774 -1401 Contr Reg No.: EVERGPS950BE Exp Date: 01/05/2013 Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 7,500 Scope of Work (please provide detailed information): FURNISH AND INSTALL (1) 100A 480/277V PANEL, (1) 100A MCB 208/120V PANEL, (1) 30 KVA TRANSFORMER. Will service be altered? ❑ Yes 0 No Adding more than 50 amps? Type of Use: COMMERCIAL Type of work: ❑ New m Addition ❑ Service Change ❑ Remodel ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service FA Yes ❑ No ❑ Tenant Improvement Property Served by: ❑ Puget Sound Energy IZ Seattle City Light H:\Applications'Forms- Applications On Line\2011 Applications\Electrical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added /altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Camivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CE Y THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF r RJUR BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: Print Name: LECTRICAL CONTRA REW MACKEY Mailing Address: 3623 EAST MARGINAL WAY SOUTH H:\Applications\Forms- Applications On Line \201 I Applications\Electrical Permit Application Revised 8.9- 11.docx Revised: August 2011 bh Date: 10/18/2012 Day Telephone: (206) 786 -1763 SEATTLE WA 98134 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0923049120 Permit Number: EL12 -0998 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 10/18/2012 Applicant: WOW TECHNOLOGIES Issue Date: Receipt No.: R12 -02903 Payment Amount: $287.63 Initials: WER Payment Date: 10/18/2012 01:12 PM User ID: 1655 Balance: $0.00 Payee: DREW MACKEY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 015264 ACCOUNT ITEM LIST: Description 287.63 Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 230.10 000.345.832.00.00 57.53 Total: $287.63 rinr. RPCaint -(1R PrintArl• 1f_1R -9019 INSPECTION NO. INSPECTION RECORD. Retain a copy with permit,. PERMIT NO. CITY OF TUKWILA BUILDING. DIVISION.: 'C 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: .t- '' ii'' %1 r,.r- W °`V i iivYl Type of Inspection: t}i�. Address: ,,,°.. u. Date Called: Special Instructions: Date Wanted:. amr, Requester: - Phone No: RIApproved per applicable codes. El Corrections requured prior to approval COMMENTS: ■ Inspector: 16ridoc, n REINSPECTION FEE REQUIRED. Prior to next inspection,' fee must -be . paid at 6300 Southcenter Blvd.. Suite 100. Call to'schedule reinspeetion.' . T, • PE PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -0998 DATE: 10 -18 -12 PROJECT NAME: WOWRACK TECHNOLOGIES SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: i& Building tvision Public Works ❑ Fire Prevention Structural n Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-23-12 Complete Incomplete C Not Applicable Comments: Permit'Center'UseOnly. - INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route U Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 -20-12 Approved ❑ Approved with Conditions Lk Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit • Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Contractors or Tradespeople Peer Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company EVERGREEN POWER SYSTEMS INC 2067741400 3623 E Marginal Way S Seattle WA 98134 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602451324 Active EVERGPS950BE Electrical Contractor 1/5/2005 1/5/2013 General Unused Electrical Administrator INFORMATION License MACKEJE216JN Name MACKEY, JAMES E Status Active Business Owner Information Name Role Effective Date Expiration Date HOPKINS, JAMES Agent 01/05/2005 Bond Amount MACKEY, JAMES E President 01/05/2005 52BSBFC2870 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 HARTFORD FIRE INS CO 52BSBFC2870 01/03/2009 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.00 12/19/2008 1 INS CO OF THE WEST 2136450 01/03/2005 Until Cancelled 01/15/2009 EVANS00322 $4,000.00 01/05/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EHRAL00865 12/8/2010 19.28.101 RCW ELECTRICAL CITATION Satisfied $500.00 EBLAG00295 1/6/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EROMA00567 5/24/2010 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EVANS00322 6/19/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip/Print.aspx 11/05/2012 FILE: P: \EPS \EPS PROJECTS \3007— WOWRACK \3007 — WOWRACK.dwg LEVEL 2 LEVEL 2 CRITICAL LOAD RACKS LEVEL 1 LEVEL P1 FAN- FAN -I A MBP-2 of 0 io 0 0 m 0 0 0 u) 0 O 1� NEW 1 PDU 2 500A w /INTERGAL XFRMR 164 CKTS i % i BATT. NEW UPS -2 500A 0(1 In4NEW 11 /0 GND50 AL U, S 1# /0 GND50 AL a. ,14•35:::) 1 }.;) NOTE: EXISTING METERED LOAD: 166A 1f 0 \o 0 \o 0 \o 12Q0 3 3?1 S 3 3 HE RD 480V, NOTE: EXISTING METERED LOAD: 128A k (2)3"C 1# 311350 /0 GND SR ATS ... >. NEW 1Y "C. 4 THHN 1 6 Green THHN v v v MB —L1 100A MCB 120/208V 304W 1Y "C. 4 #3 THHN 6 Green THHN 74pC. 3 #8 THHN 1 1/10 Green THHN NEW MB —H 100A MLO 277/480V 304W 30KVA Secondary 120/208V #6cu BLDG. BLDG. INTERIOR EXTERIOR MECH -2 500A 250A NEW SEPARATE PERMIT REQUIRED FOR: Ei Mechanical ❑ Electrical 15 Plumbing Gas Piping City of Tukwila BUILDING Di\liSION LEVEL P2 r EXlSi BLDG. BLDG. INTERIOR EXTERIOR PSE EXS 1' CRAC 45 TON 110A z ArAll Eul:...�`.. >d. LEVEL 1 (3)4 "C 4#600 Cu I NEW 1 1000KW 480V, 1600A GENERATOR (TRIP SET AT 1200A) CHILLER 100 TON 250A NEW LEVEL P1 LEVEL P2 MAIN ELEC. ROOM NOTE: RISER DIAGRAM FEEDER WIRING DESIGNATIONS SUPERCEDE PANEL SCHEDULE CALLOUTS. PANEL: MB -H1 ❑C DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 L❑CATI ❑N: DEVICE FAMILY: Bolt On MOUNTING: Flush FED FROM: VOLTAGE: 480/277 INCIDENT ENERGY: 0.00 J /cm2 @ 0. 00(i n) BOUNDARY: 0. 00( i n) MAINS(A): MLO CONTINUOUS(A): WIRING: 3 -Phase 4 -Wire BUS SC RATING(A) FAULT CURRENT( A) PPE Category: 225 65000 : 0 ❑C NOTES DESCRIPTION DEMAND VA CKT PHASE LOADS VA CKT VA DEMAND DESCRIPTI ❑N NOTES OC ❑C AMPS P CODE A B C CODE AMPS P AMPS P 0 3 X1 FEEDING PANEL MB- NONE 4682 1 2561 0 (U d- �0 CO 0 CU d- 03 0 CU d' D CD 0 (U CU d- DCO - - CU CU CU CU CU CO CO COC')(V)d'd 1000 LIGHTIN LIGHTING 20 1 20 1 "" /I II - 3 2561 1000 LIGHTIN LIGHTING 20 1 20 1 ,,° ," GENERAL - 5 1561 0 SPARE SPARE 20 1 20 3 „„ SPARE „// SPARE 0 7 0 0 - 20 1 O O SPARE - C7 LC7 0f, — (7 Ln (T — co Lf7 0� CU CU CU CU CU CO C) CO C") Co d 0 - ALL CONNECTED KVA 3P AVE AMPS * PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 6. 68 8, 0 )( A -N 2560. 6 9.2 CONNECTED 6. 68 DATE: Oct 16, 2012 TOTAL DEMAND 6,68 8. 0 ) B -N 2560. 6 - 9. 2 DEMAND 6. 68 TIME 1 1: 29: 05 - TOTAL DESIGN 7, 18 8. 6 - )K C -N 1560, 6 5. 6 DESIGN 7. 18 PELF COPY Permit No. ttri(L'Oln 1 , Pon l'v:..iw approval is subject to errors and omissions. k :)r va1 of construction documents does not authcte k;]olaiion of any adopted code or ordinance. Rocc pt 01 Lpproved Field Copy and conditions is acknowledged: By per. Date: )117/i .) City Of ltikwIla BUILDING DIVISION REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC OCT 3 0 2012 oVN.0 PANEL: MB -L1 OC DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 L❑CATI ❑N: DEVICE FAMILY: Bolt On MOUNTING: Flush FED FROM: BUS -0005 VOLTAGE: 208/120 INCIDENT ENERGY: 0. 00 J /cm2 @ 0, 00( i n) BOUNDARY: 0. 00( i n) MAINS(A): BKR s C❑NTINU❑US(A): 225 WIRING: - 3 -Phase 4 -Wire BUS SC RATING(A) 65000 FAULT CURRENT(A): 0 PPE Category: ❑C NOTES DESCRIPTION DEMAND VA CKT PHASE LOADS VA CKT VA DEMAND DESCRIPTI ❑N NOTES OC AMPS P CODE A B C CODE AMPS P 20 2 GEN BATTERY CHARGER GENERAL 2080 1 1240 0 OJ 0000CUd- k.0000CUd- .D 00 (U CU d- k,D CO CU CU CU CU CU 00 C') co C') co d 200 GENERAL GEN OUTLETS 20 1 "" II II - 3 1040 0 SPARE GEN SPARE 20 1 20 1 GEN BLOCK HEATER GENERAL 1201 5 1201 20 1 GEN BLOCK HEATER GENERAL 1201 7 1201 20 1 SPARE SPARE 0 9 - 0 - 11 13 - - 15 17 19 21 23 25 27 29 31 33 - 35 37 39 41 ALL CONNECTED KVA 3P AVE AMPS * PHASE TOTALS VA AMPS BUS TOTALS - KVA TOTAL CONNECTED 4.68 13.0 E A -N 2440. 9 20, 3 CONNECTED 4. 68 DATE: Oct 16, 2012 TOTAL DEMAND 4, 68 13, 0 K B -N 1040, 0 8. 7 DEMAND 4. 68 TIME: 1 1: 29: 05 TOTAL DESIGN 4,68 13. 0 * C -N 1200,9 10, 0 DESIGN 4. 68 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. t. "7,77: i'svia ions will require a new -I rrmy i:Z ;lode add iienal plan submittal plan review t t. City of .T U LDING I �SON_ RECEIVED CITY OF TUKWILA OCT 18 2012 PERMIT CENTER ELl LY??B WOWRACK GATEWAY CORP. PARK BUILDING B 12201 Tukwila Intl. Blvd. Tukwila, Washington Revisions No: Item: EVERGREEN POWER SYSTEMS INC. Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774 -1400 Fax: (206) 774 -1401 Dote: 1 PERMIT SET 05/25/11 A PERMIT SET REV. 10/05/12 Project Number: 3007 10/16/12 - 12:41pm MRP JB Arch. Bckgrnd.: 03/18/10 Plot Date: Drawn By: Checked By: Drawing Name: 3007 - WOWRACK.dwg Title : ONE -LINE DIAGRAM PERMIT SET Sheet : E5.00