Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL12-1088 - WESTFIELD SOUTHCENTER MALL - SOMA INTIMATES
SOMA INTIMATES 260 SOUTHCENTER MALL EL1 2-1088 City ofitukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 9202470010 Address: 260 SOUTHCENTER MALL TUICW Project Name: SOMA INTIMATES ELECTRICAL PERMIT Permit Number: EL12 -1088 Issue Date: 02/04/2013 Permit Expires On: 08/03/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: MARY RYAN Address: PO BOX 3749 , MISSION VIEJO CA, 92690 Contractor: Name: ORCA ELECTRICAL CONTRACTORS Address: 2704 171 ST SE , BOTHELL WA 98012 Contractor License No: ORCAEEC944NU Phone: 949 582 -3735 Phone: 425 487 -2636 Expiration Date: 08/31/2010 DESCRIPTION OF WORK: 200 AMP PANEL CHANGE OUT Value of Electrical: NRES: $20,000.00 RES: $0.00 Fees Collected: Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: $545.63 2008 I hereby certify that I have read and x ned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie with whether specified herein or not. The granting of this permit does not pr sul!ne to give authori to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am autho -' o sign and obtain this electrical permit. Signature Date: Print Name: ' • !/'I4 �oL This permit shall become nu jand void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL12 -1088 Printed: 02 -04 -2013 • PERMIT CONDITIONS • Permit No. EL12 -1088 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -1088 Printed: 02 -04 -2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ht-tp://www.TulcwilaWA.gov Electrical Permit No. Project No t1,4- long Date Application Accepted: Date Application Expires: O ( 1 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's T Site Address: i ti% 1,4 (/i/4..4._ Suite Nun itt Tenant Name: PROPERTY OWNER Name: Gs? / E /, C t �� � i Address: 1/ / / 1/ ,L4 Blvd; /l City: a C .4A/40 0 G p State:/ it — ZGA 4_794 CONTACT PERSON — person receiving all project .. communication /ft ,.., 4 /.4.1/_ /s: will. /4r Addrrees 1 BG 3 7 �L � ) Ci State: iii ss /6� J/ 6 Zi , f— ..AR 6; Phoney 4 3 7 _7l 2 , Email/14-1e Y 6 0CI. •fetI .ia�,GIV - e. /L No.: l `V 2L"1 1 'DO 1, 714 Floor: NCfw Tenant: ❑ Yes ELECTRICAL CONTRACTOR INFORMATION Company Nam%V * S4 C� (�,w / IA Address: /^ /, 0 S S'V N Z Uet . �.�a City4Yaire_Y /, /E State4 / Zip ) PhonC * 59fb ' —6 :, 31_3 Contr Reg No.: S �0 3 LL Exp Date: Tukwila Business License No.: Oi Valuation of Project (contractor's bid price): $ , 60 0 )--00 AAA/0 1'A/in Scope of Work (please provide detailed information): TT4/'T4'7 t3&/ /U -f— d 'v ki/ Affev& ,v,L, Se9-e_. �N iv/ 6.t/ S T-N 2- ev Will service be altered? ❑ Yes Type of Use: E'j7t1/41'L Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator jki No ❑ Service Change ❑ Fire Alarm Pro Served b : Puget Sound Energy ❑ Seattle City Light H:Wpplications\Forms- Applications On Line'2011 Applications\Electrical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Adding more than 50 amps? Yes ❑ No 42 ❑ Remodel ®' Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ..... $152.85 (including an attached age) ❑ Garages, pools, spas an utbuildings $81.90 ea ❑ Low voltage system (alarm, fern thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 eal ❑ Circuits added/altered without service than $54.60 (up to 5 circuits) r�C ❑ Circuits added/altered without se ce c e $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) PERMIT;APPLICATION NOTES MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea OkI i.o AM? 141-11E-1- r 1% I E Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: Ly v• /3 Date: l� 22 il/ M �ePa 7.3s Day Telephone: o P‘C� Cit state Zip I1:Wpplications\Forms- Applications On Line \2011 Applications\Electrical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page2of2 Cif" of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukw ila. wa. us SET RECEIPT Copy Reprinted on 02 -04 -2013 at 11:51:17 02/04/2013 RECEIPT NO: R13 -00697 Initials: JEM Payment Date: 02/04/2013 User ID: 1165 Total Payment: 2,538.32 Payee: DENNIS M FILAND (BY PHONE) SET ID: 0204 SET NAME: Temporary Set SET TRANSACTIONS: Set Member Amount D12 -367 1,930.15 EL12 -1088 443.32 PG12 -202 164.85 TOTAL: TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 2,538.32 TOTAL: 2,538.32 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE 000.322.100 000.322.101.00.0 000.345.832.00.0 000.322.103.00.0 640.237.114 TOTAL: 1,925.65 436.50 6.82 164.85 4.50 2,538.32 City of T ila, Department of Community Development 6300 Southceder Boulevard, S uite 6100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: hup./Snww. ci. Mkwila. wa. us SET RECEIPT • Copy Reprinted on 11 -19 -2012 at 09:43:58 11/19/2012 RECEIPT NO: R12 -03149 Initials: JEM User ID: 1165 Payee: PERMIT RESOURCES, INC. Payment Date: 11/19/2012 Total Payment: 1,461.30 SET ID: S000001828 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D12 -367 1,251.67 EL12 -1088 102.31 M12 -180 66.11 PG12 -202 41.21 TOTAL: 1,251.67 TRANSACTION LIST: Type Method Description Amount Payment Check 21601 1,461.30 TOTAL: 1,461.30 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 TOTAL: 102.31 1,358.99 1,461.30 / INSPECTION RECORD 6300 _'��} (� Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 3670 Permit Inspection Request Line (206) 431 -2451 Project: �rik. Type of Inspection: � `�v ` Address: � t1 �1/ 0 ti Date Called: Special Instructions: Date Wanted:. Por a:m m. Requester: Phone No: Approved per applicable codes. COMMENTS: Corrections required prior to approval. Date: 6.3/2/5/13 ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING; DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 5 ktlikTr.5Type of Inspection: Address: AO 4411A.,i Date Called: Special Instructions: 1 Oltf( Date Wanted:. a. ., Si Requester: f Phone No: ElApproved per applicable codes. D Corrections required prior to approval. COMMENTS: 1 — ST-04 Sriti+ GAk V U4-5 uijL :v1m 45 1 - P cl-T: - 8v138a ec›./ mi c srtP u1R sEkthei AI norsI c JDJ, r 3uPI Ar. c.A4- 4(4C. Kw:tj S - ct osC ,0i %1n' .T Awes - i •ls -plc; gJS,i -t,JL 411- Inspector: "Jilt f F411/64i Date :03/2, n REINSPECTION FEE REQUI ED. Prior to next inspection, fee must be ' paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPFCTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 , (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 1,1Z -roa'8 Project: /ham Type of Inspection: ___ 7000 Address: ��� e Hr, ut f Date Called: Special Instructions: /4 4(5N Date Wanted: a.m. ..m\ Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: 1 bLID Inspector: 6Sitc Date: Oz CIS el n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. • PERMIT NO. CITY OF TUKWILA BUILDING D IVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 (206) 431 -3670 Project: �� �� 1 p ' Type of Inspection: Date Called: -706317001 Address: 240° litAti/ Special Instructions: q 7 .CEO 4••. Date Wanted:. .2- a.m .m. m. Requester: r (11.) Phone No: r777Al P1oor! 1-4421-05 _. ,. — c?JE'',A 1JkU..S.e-s it Approved per applicable codes. Corrections required prior to approval. COMMENTS: 7io j I &A/1)1111j 7ao5 e W i015 )?I (11.) enigool AO r777Al P1oor! 1-4421-05 _. ,. — c?JE'',A 1JkU..S.e-s it Inspector: ovAieik Date: a 2X, I/3 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Z INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ! (206)431 -3670 Project: in Type of Inspection: Address: ai 0 C.....4 AA all Date Called: - /J o &1T r,J Cod,no G1i71 4 cb/e,e, -^£. Special Instructions: Date Wanted: q a.m. (i p.m. Requester: �`!in e C Phone No: A /t' ( , Approved per applicable codes. Corrections required prior to approval. c COMMENTS: — ktIt OA/ At, f C FI,E,c AJtcPa q-- iLi--44.. - Lc c.o cia1 ciNi ('1 r co/vat- a 5 - /J o &1T r,J Cod,no G1i71 4 cb/e,e, -^£. /ni STS W) 47,0 JJ Ol AS sc"'� Inspector: CAWel ❑ $60.00 REINSPECTION FEE hEQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: OL r q ' 2 Receipt No.: Date: -:x''` l =,v .,.._d<;�C. „'F. LK'',.s. .a.'- ."".r.' . f >-!"?'' c� '. " - ?'i�.<.. ,i r-- .,+y.ti:.= 'h"GP-•-�`.- —.- - -a; :.- INSPECTION :NO. CITY: OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 AO, (206) 431 -3670 Permit Inspection _RequestLine (206) 431 -2451 INSPECTION RECORD Retain a copy with permit fu2'o8E PERMIT NO.. Project: _.- --3(5 rinkrel 14 Type of Inspection: /00 Address. Date Called: Special Instructions: Date Wanted: . #00 /a. P Requester: Phone No ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: Coda 2 oartc-5 04 we-sr we-s X t i59^i( w °ro ikhc -i t 5 Inspector: • ra,mtr- /1604leic Date:02/00 3 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid -at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2009 Washington State E Project Summary 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Code Compliance Form for Nonresidential - ultifamily Residential PRJ -SUM Revised December 2010 Project Info Project Address WESTFIELD SOUTHCENTER MALL Date 11/8/2012 2800 SOUTHCENTER MALL, SPACE: 116 For Building Department Use _ ,, pin A tribg141 an- TUKWILA, WA 98188 Applicant Name: SHREMSHOCK ENGINEERING INC Applicant Address: 6130 S. SL)NBURY RD WESTERVILLE oH, 43081 Applicant Phone: 614 -645 -4550 r. REVIEWS FOR COMPLIANCE OC NEC NFPA NOV 2 8 2012 City of Tukwila BUILDING E$VED . CITY RE 0 TUK!MlA Nnv 1, 9 2012 PERMIT CENTER .ELIT IOU 2009 Washington State y Code Compliance Form for Nonresidential - Multifamily Residential Interior Lighting Summary Compliance Forms for Nonresidential and Multifamily Residential LTG -INT Revised December 2010 Project Info Project Address WESTFIELD SOUTHCENTER MALL Date 11/8/2012 2800 SOUTHCENTER MALL, SPACE: 116 For Building Department Use TUKWILA, WA 98188 Applicant Name: sHREMSHOCK ENGINEERING INC Applicant Address: 6130 S. SUNBURY RD WESTERVILLE OH, 43081 Applicant Phone: 614 - 545 -4550 Project Description SALES FLOOR ❑ Plans Induded requirements. -, New Building ❑ Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option Q Prescriptive 0 Lighting Pourer Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allowed Watts per ft 2 " Gross Interior Area in ft2 Allowed x Area E2.0 SALES 1.33 1767 2350 SALES FLOOR ADDITIONAL ALLOWANCE OF 1.4W PER SQ FT 1.40 1767 2474 FITTING ROOMS ADDITIONAL ALLOWANCE OF 1000W (SPACE OVER 250SQ FT) 1.00 1000 1000 FITTING ROOMS NON SALES (WAREHOUSE) 0.50 297 149 DISPLAY CASE TOILET ROOM 0.80 136 109 "* From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 6081 Provosed Li htin;; Wattage Location (floor plan /room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed SALES FLOOR A - RECESSED CAN LIGHT - 1 - 42W PLT LAMP ELECTRONIC E 25 48 1200 SALES FLOOR PD -1 PENDANT FIXTURE - 2 - 60W INCANDESCENT 2 350 700 FITTING ROOMS SC -2 WALL SCONCE - 1 -40W INCANDESCENT 12 40 480 FITTING ROOMS SC -1 WALL SCONCE 3 -60W INCANDESCENT 2 180 360 DISPLAY CASE CL - 2 - 32W -T8 - ELECTRONIC BALLAST 4 62 248 SALES FLOOR TRACK USE CL PANEL - 10 A Current limiter 10 120 1200 NON SALES CL -2 1- 32W T8 - ELECTRONIC BALLAST 7 32 224 LAVATORY /HALLWAY CL -1 1- 32W -T8 - ELECTRONIC BALLAST 1 • 32 32 SALES FLOOR TRACK USE CL PANEL - 4 A Current limiter 4 120 480 SALES FLOOR TRACK USE CL PANEL - 9 A Current limiter 9 120 1080 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 6004 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2009 Washington State y Code Compliance Form for Nonresidential . Multifamily Residential Interior Lighting Summary (back) nergy Code Compliance Forms for Nonresidential and Multifamily Residential LTG -INT Revised December 2010 Prescriptive Spaces Occupancy: Q Warehouse or Parking Garage Q Other Qualification Checklist Note: If occupancy is "Other' and fixture P type answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) j Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T-8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL factures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. -1 Unit Lighting Power Allowance (LPA Use' LPA (W /ft`) Use' LPAZ (Wfft`) Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments', restaurants/bars5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelvingl 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel/motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies° (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w /ft2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of fumiture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories 1, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be tumed off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. 2009 Washington State E y Code Compliance Form for Nonresidential ultifamily Residential Exterior Lighting Summary LTG -EXT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Proj Addres:WESTFIELD SOUTHCENTER MATT. Date 11/8/2012 2800 SOUTHCENTER MALL, SPACE: 116 For Building Department Use TUKWILA, WA 98188 Name: SHREMSHOCK ENGINEERING INC Appl. Name 6130 S. SUNBURY RD WESTERVILLE OH, 43081 Appl. Phone 614 -545 -4550 Project Description ❑ Alteration ❑ Plans Induded and commissioning requirements. ❑ New • Addition Refer to WSEC Section 1513 for controls Lighting Zone (as specified by Jurisdiction) O Zone 1 Zone 2 Q Zone 3 0 Zone 4 Compliance Option Q Lighting Power Allowance Q Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 Iumens/W ❑ Controlled by motion sensor ❑ Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed. ❑ Less than 60% of fixtures are new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage Base Site Allowance: Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft`), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Total Allowed Tradable Watts: Tradable Proposed Lighting Wattage (use mfgr listed maximum input wattage for luminaire.) Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Total proposed tradable watts may not exceed the sum of total allowed tradable watts plus the base site allowance. Any base site allowance not needed to make tradable watts comply can be applied to individual non - tradable categories. Total Proposed Tradable Watts: Non - Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: Fixture Description Non - Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Non - Tradable Proposed Lighting Wattage Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Non - tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non - tradable surfaces are Tess than the remaining site allowance. Total excess Non - Tradable watts: Site Allowance Balance: 2009 Washington State y Code Compliance Form for Nonresidential • Multifamily Residential Exterior Lighting Summary (back) LTG -EXT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential TABLE 15 -2B LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised December 2010 Specific area description Zone 1 500 W Zone 2 600 W Zone 3 750 W Zone 4 1300 W Base site allowance' Tradable Surfaces 2 Uncovered Parking Parking lots and drives Areas 0.04 W /ft2 0.06 W /ft2 0.10 W /fe 0.13 W /ft2 Building Grounds Walkways less than 10 ft wide 0.7 W/linear foot 0.7 W/ linear foot 0.8 W/ linear foot 1.0 W/ linear foot Walkways 10 ft wide or greater Plaza areas Special feature areas 0.14 W /ft2 0.14 W /ft2 0.16 W /ft2 0.2 W /ft2 Exterior Stairways 0.75 W /ft2 1.0 W/ft2 .0 W/ft2 1.0 W /ft2 Pedestrian tunnel 0.15 W /ft2 0.15 W /ft2 0.2 W /ft2 0.3 W /ft2 Landscaping 0.04 W /ft2 0.05 W /ft2 0.05 W /ft2 0.05 W /ft2 Building Entrances and Exits Main entries 20 W/linear foot of door width 20 W /linear foot of door width 30 W/linear foot of door width 30 W/linear foot of door width Other doors 20 W/linear foot of door width 20 W/linear foot of door width 20 W/linear foot of door width 20 W/linear foot of door width Entry canopies 0.25 W/ft2 0.25 W /ft2 0.4 W/ft2 0.4 W/ft2 Sales Canopies Free standing and attached 0.6 W /ft2 0.6 W/ft2 0.8 W /ft2 1.0 W/ft2 Outdoor Sales Open areas3 0.25 W /ft2 0.25 W /ft2 0.5 W /ft2 0.7 W /ft2 Street frontage for vehicle sales lots in addition to `open area allowance No Allowance 10 W/linear foot 10 W /linear foot 30 W/linear foot Non - Tradable Surfaces` Building Facades No Allowance 0.1 W /ft2 for each illuminated wall or surfaces 0.15 W/ft2 for each illuminated wall or surface6 0.2 W /RZ for each illuminated wall or surface' Automated teller machines and night depositories 270 W per locations 270 W per locations 270 W per locations 270 W per locations Entrances and gatehouse inspection stations at guarded facilities 0.75 W/ft2 of covered & uncovered area Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W/ft2 f covered & uncovered area Material handling and associated storage No Allowance No Allowance No Allowance 10.5 WI& Drive -up Windows & Doors 400W per drive- through Parking near 24 -hour retail entrances 800 W per main entry FOOTNOTES FOR TABLE 15 -2B: 1. Base site allowance may be used in tradable or nontradable surfaces. 2. Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded. 3. Including vehicle sales lots. 4. Lighting power density calculations for the following applications can be used only for the specific application and cannot be tradf between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted i the "Tradable Surfaces" section of this table. 5. May alternately use 2.5 watts per linear foot for each wall or surface length. 6. May alternately use 3.75 watts per linear foot for each wall or surface length. 7. May alternately use 5 watts per linear foot for each wall or surface length. 8. An additional 90 watts is allowed per additional ATM location. 2009 Washington State y Code Compliance Form for Nonresidential . Multifamily Residential Lighting Power Allowance Adjustments LTG -LPA 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address WESTFIELD SOUTHCENTER MALL Date 11/8/2012 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor plan /room #) Occupancy Description Allowed Watts per ft2** Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per ft2 "' From Table 15-1 based on exceptions listed in footnotes 2009 Washington State E y Code Compliance Form for Nonresidential gifilVlultifamily Residential Lighting, 2009 Washington Motor, and 'i ransformer Permit Plans L,necklist LTG -CHK State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address WESTFIELD SOUTHCENTER MALL IDate 11/8/2012 The following information is necessary to check a permit application for compliance with the lighting, motor, and t ansfomier requirements in the 2009 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) Yes 1513.1 Local controVaccess Schedule with type, indicate locations E3.0 Yes 1513.2 Area controls Maximum limit per switch E3.0 N.A. 1513.3 Daylight zone control Schedule with type and features, indicate locations Yes vertical glazing Indicate vertical glazing on plans N.A. overhead glazing Indicate overhead glazing on plans Yes 1513.4 Display /exhib /special Indicate separate controls E3.0 N.A. 1513.5 Exterior shut -off Schedule with type and features, indicate location Yes (a) timer w /backup Indicate location N.A. (b) photocell. Indicate location N.A. 1513.6 Inter. auto shut -off Indicate location Yes 1513.6.1 (a) occup. sensors Schedule with type and locations N.A. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans N.A. 1513.7 Hotel/motel controls Indicate location of room master controls N.A. 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) Yes I 1514 IMax. watts 'Indicate watts for each exit sign 1 1 LIGHTING POWER ALLOWANCE (Section 1530 -1532) Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture N.A. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) Yes I 1511 I Elec motor efficiency I MECH -MOT or Equipment Schedule with hp, rpm, efficiency I TRANSFORMERS (Section 1540) N.A. I 1540 (Transformers 'Indicate size and efficiency 1 I If "no" is circled for any question, provide explanation: %RMIi COORD CORY ` PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -1088 DATE: 11/19/12 PROJECT NAME: SOMA INTIMATES SITE ADDRESS: 260 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural El Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11/20/12 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route 171 REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 12/18/12 Approved ❑ Approved with Conditions a Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople liter Friendly Page Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company ORCA ELECTRICAL CONTRACTORS 4255850101 2704 171St St Se Bothell WA 98012 Snohomish Limited Liability Company UBI No. Status License, No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602644540 Active ORCAEEC944NU Electrical Contractor 8/31/2006 9/5/2014 General Unused Master Electrician INFORMATION License CABUAB'966MB Name CABUAG, BARNEY Status Active Business Owner Information Name Role Effective Date Expiration Date CABUAG, JOHANNA M Partner /Member 08/31/2006 Bond Amount CABUAG , JACOB K M SR Partner /Member 09/25/2006 100207189 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 American Contractors Indem CO 100207189 10/09/2012 Until Cancelled $4,000.0010/10/2012 2 Platte River Ins Co 41232827 08/13/2011, Until Cancelled 10/08/2012 $4,000.0008/15/2011 1 CBIC SG9027 08/31/2006 Until Cancelled 08/13/2011 $4,000.0008/31/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount ECERM00661 3/28/2011 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip/Print.aspx 02/04/2013 DESIGN DRAWINGS ARE SCI- IEMATIC. THE CONTRACTOR SMALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS: THE CONTRACTOR SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. 2. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR TENANT PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN THIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR TENANT AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT THE CONTRACTORS COST. 3. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, TI-4E PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR TENANT OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING GODES AND DESIGN INTENT. 4. REFER TO MECHANICAL PLAN FOR LOCATION OF MECHANICAL EQUIPMENT. FIELD VERIFY EXACT LOCATIONS. PROVIDE ALL CONVENIENCE RECEPTACLES, SAFETY SWITCHES, WIRING, OR OTHER EQUIPMENT TO ENSURE A COMPLETE AND OPERABLE HVAC SYSTEM, 5. ALL CEILING MOUNTED RECEPTACLES AND COVERPLATES IN WHITE CEILING SHALL BE WHITE. 6. ALL WALL MOUNTED RECEPTACLES, SWITCHES, AND COVERPLATES SHALL BE WHITE. 7. CONDUIT FOR DATA /TELEPHONE OUTLETS AND LOW VOLTAGE CABLING SHALL HAVE A PULL /JUNCTION BOX INSTALLED AFTER EACH SET OF THREE 90 DEGREE BENDS. 8. LABEL ALL COVERPLATES ON INSIDE FACE OF PLATE WITH CIRCUIT NUMBER AND PANEL DESIGNATION. I.E. 'A -l'. CIRCUIT SHALL BE WRITTEN WITH PERMANENT MARKER IN A CONTRASTING COLOR. 9: LOW VOLTAGE VENDOR TO PROVIDE REQUIRED TELEPHONE CABLING AND MAKE NECESSARY CONNECTIONS. 10. CONDUIT FOR SPEAKER, TELEPHONE AND DATA CABLING FROM CASNWRAP SHALL STUB OUT BELOW THE CEILING ABOVE BACKBOARD WITH A BUSHING TO PROTECT THE CABLE FROM THE EDGES OF THE CONDUIT. 11. ALL HORIZONTAL CABLING FOR VOICE AND DATA SHALL BE CATEGORY 5E RATED. 12. PROVIDE ALL BACKBOXES AND CONDUIT FOR THE COMMUNICATIONS OUTLETS. 13. ALL GABLES AND DEVICES TO BE INSTALLED ABOVE FINISHED CEILING SHALL BE PLENUM RATED OR IN CONDUIT. 14. REFER TO SPECIFICATIONS SECTIONS 26 27 26 WIRING DEVICES FOR EXACT ' MODEL NUMBER OF DEVICES TO BE USED 15. FIELD VERIFY ALL CONDITIONS. 1. ELECTRICAL SERVICE EQUIPMENT: 13. UNDER FLOOR CONDUIT (GENERAL CONTRACTOR TO USE APPROPRIATE METHOD): PROVIDE ALL EQUIPMENT AS REQUIRED IN GENERAL NOTES, SPECIFICATIONS, AND AS SHOWN TRENCI -I: (1) COMMON TRENCI -I FOR CONDUITS RUN BELOW FLOOR. TRENCHING AND CONDUIT 26.I -IVAC RECEPTACLE: ON FLOOR PLANS, AND RISER DIAGRAM. MAINTAIN CODE REQUIRED CLEARANCES FOR ALL TO BE EXTENDED FROM THE ACCESS PANEL AT T1-4E BOTTOM OF TI-4E CASNWRAP TO INSIDE PROVIDE POWER CONNECTION TO RECEPTACLE PROVIDED WITH RTU. EQUIPMENT PER NEC 110.26. NEAREST FULL I- IEIGNT ALL TRENCH AND PATCH AS REQUIRED. GENERAL CONTRACTOR TO VERIFY WITH LANDLORD FLOOR SLAB SAW CUTTING /TRENCHING REQUIREMENTS PRIOR TO BID. 27. MECHANICAL EQUIPP'IENT CONNECTIONS: 2. CASH WRAP UTILITY RECEPTACLE: PROVIDE FEEDERS AND DISCONNECTS PER MECHANICAL EQUIPMENT FEEDER /CONNECTION 20 AMP, 120V., QUADRUPLEX RECEPTACLE AT CASH WRAP COUNTER FOR UTILITY POWER. 14. SHON WINDOW RECEPTACLE - CEILING: SCHEDULE. REFER TO DETAIL 'L' ON SHEET E4.0. LOCATE AS DIRECTED BY TENANT /ARCHITECT. CONNECT CIRCUIT AS INDICATED. REFER TO RECEPTACLES WITH 'SF' DESIGNATION SHALL BE MOUNTED FLUSH IN CEILING AT STOREFRONT CODED NOTE #12 FOR CONDUIT REQUIREMENTS. PARALLEL TO STOREFRONT GLASS. REFER TO ARCHITECTURAL SHEETS FOR EXACT 28. HVAC THERMOSTAT /SENSOR: LOCATIONS. COORDINATE LOCATIONS WITH LOCAL ARCHITECTURAL ELEMENTS AND TRACK THERMOSTAT /SENSOR LOCATION TO BE ,COORDINATED WITH TENANT. PROVIDE 4" SQUARE 3, CASH WRAP DEDICATED RECEPTACLE: LIGHTS. I- IOMERUN CIRCUIT THROUGH CONTACTOR CONTROLLED BY TIME CLOCK PANEL. BACKBOX AND 1/2" CONDUIT WITH PULLSTRING, BETWEEN THERMOSTAT /SENSOR LOCATION 20 AMP, 120V., ISOLATED GROUND, DEDICATED CIRCUIT, RECEPTACLE FOR EACH CASH REFER TO LIGHTING CONTROL DETAIL 'N' ON 51-IEET E3.0. AND VAC UNIT IT ;SERVES. REGISTER. LOCATE AS DIRECTED BY TENANT /ARCHITECT. CIRCUIT AS INDICATED. PROVIDE A SEPARATE ISOLATED GROUND CONDUCTOR FOR EACH CIRCUIT. DO NOT INSTALL WITH ANY 15. SALES FLOOR RECEPTACLE: 29. DUCT SMOKE DETE TOR /REMOTE TEST STATION: OTHER CIRCUITS. REFER TO CODED NOTE #12 FOR CONDUIT REQUIREMENTS. LOCATIONS ARE TO BE CONFIRMED WITH TENANT'S REPRESENTATIVE PRIOR TO INSTALLATION. DUCT MOUNTED SM, KE DETECTOR FIELD INSTALLED. GENERAL CONTRACTOR SHALL INTERLOCK SMOKE DETECTOR WITH HVAC UNIT AND FIRE ALARM SYSTEM AND MAKE ALL 4. GASH WRAP TELEPHONE OUTLET: 16. SOUND SYSTEM: FINAL CONNECTIONS AS REQUIRED FOR A COMPLETE SYSTEM. HVAG UNIT TO SHUT DOWN TELEPHONE OUTLET FOR CASH REGISTER, USE 4" SQUARE BOX. PROVIDE CABLING AND MAKE PROVIDE (2) 4" X 4" JUNCTION BOXES WITH COVERPLATES AND A 1" CONDUIT BETWEEN THE UPON ACTIVATION OF SMOKE DETECTOR. COORDINATE WITH LANDLORD TO AVOID CONFLICTS FINAL CONNECTIONS. COORDINATE EXACT REQUIREMENTS /LOCATIONS WITH TENANT/ARCHITECT. BOXES. MOUNT ONE BOX AT 72" AFF AND THE OTHER BOX ABOVE THE CEILING (IF NO IN FIELD. REFER TO CODED NOTE #12 FOR CONDUIT REQUIREMENTS. CEILING MOUNT BOX AT 12' AFF). REFER TO ARCHITECTURAL DETAILS FOR MORE INFORMATION. 30. FIRE ALARM MANUAL PULL STATION: 5. CASH WRAP DATA OUTLET: PROVIDE FIRE ALARM MANUAL PULL STATION AND CONNECT TO PANEL. FIELD VERIFY EXACT DATA OUTLET FOR CASH REGISTER, USE 4" SQUARE BOX. PROVIDE CABLING AND MAKE FINAL 17: SECURITY DOME: LOCATION AND REQUIREMENTS. CONNECTIONS. COORDINATE EXACT REQUIREMENTS /LOCATIONS WITH TENANT /ARCHITECT. SECURITY CAMERA (DOME) FOR CCTV SYSTEM. REFER TO CCTV SYSTEM ON DETAIL 'B' ON REFER TO CODED NOTE #12 FOR CONDUIT REQUIREMENTS. SHEET E3.0, FOR INSTALLATION REQUIREMENTS. 31. FIRE ALARM HORN /STROBE: PROVIDE FIRE ALARM HORN /STROBE, AND CONNECT TO PANEL. FIELD VERIFY EXACT 6. TELEPHONE BOARD: 18. CCTV SYSTEM: LOCATION AND REQUIREMENTS. (C) INDICATES CEILING MOUNTED DEVICES. 4'x8'x3/4" PLYWOOD TELEPHONE BOARD PAINTED WITH (2) COATS OF FIRE RETARDANT PROVIDE ISOLATED GROUND RECEPTACLE FOR CCTV SECURITY SYSTEM. COORDINATE E EXACT PAINT, MOUNTED VERTICALLY. REFER TO SHEET E3.0, DETAIL 'L' FOR MORE INFORMATION. LOCATION IN FIELD WITH SECURITY VENDOR. REFER TO CCTV SYSTEM DETAIL 'B' ON SHEET 32. FIRE ALARM AUDIO SPEAKER STROBE: E3.0 FOR ADDITIONAL INFORMATION. PROVIDE FIRE ALARM STROBE AND CONNECT TO PANEL. FIELD VERIFY EXACT LOCATION AND 7. SECURITY SYSTEM: REQUIREMENTS. (C) INDICATES CEILING MOUNTED DEVICES. JUNCTION BOX, I.G. DUPLEX RECEPTACLE, AND DATA OUTLET FOR ADT SECURITY SYSTEM. 19. OWNER: Ch 11215. METRO FT. MYERS, ' O PARKWAY FL. 33966 ARCHITECT / ENGINEER: E E 8 8 - �C a w y m a2i c `B N O 0 c 1 V) 2 r CABINET UNIT HEATER. COORDINATE EXACT REQUIREMENTS WITH SECURITY VENDOR. REFER TO SHEET E3.0, DETAIL 1'1:OVIDE POWER CONNECTION FOR CABSNCT UNIT HCATCR 33, FIRE ALARM CEILING MOUNTED SMOKE 1.� __ KW. 120V. IPH. 20A/11'H. DETECTOR: 'L' FOR MORE INFORMATION. - - e - - - .• ' ' _. . . PROVIDE FIRE ALARM CEILING MOUNTED SMOKE 00 ° • co C p 0) ai MARK SYMBOL DESCRIPTION INPUT WATTS 1. DESIGN DRAWINGS ARE SCHEMATIC. TI-4E CONTRACTOR SI -TALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THE CONTRACTOR SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. 2. THE CONTRACTOR SHALL CONTACT THE ARCHITECT ENGINEER OR TENANT PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN THE BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCH' TECT, ENGINEER OR TENANT AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT THE CONTRACTORS COST. 3: BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR TENANT OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT 4. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. 5. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND QUANTITY OF LIGHTING FIXTURES 6. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE (120/277 VOLT INPUT) WITH BATTERY BACKUP. 7. CONTRACTOR IS RESPONSIBLE FOR ALL REFLECTED CEILING PLAN NOTES ON ARCHITECTURAL DRAW INGS. 8. FIELD VERIFY ALL CONDITIONS 1. LIGHTING CIRCUIT - ZONE '0' : CIRCUIT TO BE CONTROLLED BY SINGLE POLE SWITCH AS SHOWN IN LIGHTING CONTROL DETAIL 'N' ON S1 -IEET E3.0. SWITCH SHALL BE EQUIPPED WITN PILOT LIGHT, INDICATING THE CONDITION OF THE LIGHTS BEING CONTROLLED. 2. LIGHTING CIRCUIT - ZONE 'b' : CIRCUIT TO BE CONTROLLED BY TWO POLE SWITCH AS 5HOWN IN LIGHTING CONTROL DETAIL 'N' ON SHEET E3.0. SNITCH SHALL BE EQUIPPED WITN PILOT LIGHT, INDICATING THE CONDITION OF THE LIGHTS BEING CONTROLLED. 3. LIGHTING CIRCUIT - ZONE 'c' CONNECT CIRCUIT THROUGH CONTACTOR CONTROLLED BY SINGLE POLE SWITCH AS I I SHOWN IN LIGHTING CONTROL DETAIL 'N' ON SHEET E3.0. SWITCH SHALL BE EQUIPPED WITH PILOT LIGHT INDICATING THE CONDITION OF THE LIGHTS BEING CONTROLLED. 4. MASTER LIGHTING SWITCWBANK: PROVIDE GANGED SWITCH LOCATION FOR LOCAL LIGHTING SWITCHES. PROVIDE UNDER COMMON FACEPLATE OR MULTIPLE FACEPLATES OF EQUAL WIDTHS. SEE 'LIGHTING CONTROL DETAIL' ON SHEET E3.0, DETAIL 'N'. ALL SWITCHES TO BE PILOT TYPE, LIGHTS ON WHEN SWITCH IS ON. 5. STORE FRONT SIGN: PROVIDE JUNCTION BOX AND TOGGLE TYPE DISCONNECT SWITCH, WITH MINIMUM 12" WHIP FOR CONNECTION TO THE STORE FRONT SIGN. LOCATE ABOVE CEILING NEAR ACCESS PANEL. COORDINATE EXACT REQUIREMENTS WITH SIGN VENDOR. 6. SHOW WINDOW LIGHTING AND SIGN: NOME RUN THROUGH CONTACTOR CONTROLLED BY TIMECLOCK. TIMECLOCK SHALL BE A 24 HOUR 7 -DAY WITH SKIP -A -DAY FEATURE, "TORK" SERIES DWZIOOB. , SCHEDULE TIMECLOCK TO TURN ON 1/2 POUR BEFORE STORE OPENING AND OFF AT MIDNIGHT. CONTACTOR AND TIMECLOCK SHALL BE WALL MOUNTED ADJACENT TO PANELS. 7, TRACK LIGHTING ALIGNMENT: - TRACK FOR TRACK LIGHTING SHALL BE INSTALLED AS SHOWN IN 'TRACK LIGHT ALIGNMENT DETAIL' DETAIL 'J' ON SHEET E3.0. r S. SALES AREA EMERGENCY/NIGHT LIGHT /EXIT CIRCUIT: ALL SALES AREA EMERGENCY LIG1 -ITS, NIGHT LIGHTS, AND EXIT LIGHTS SHALL BE CONNECTED TO UNSWITCHED CIRCUIT 'A -35'. FIXTURES ARE TO PROVIDE CONTINUOUS EGRESS AND EMERGENCY ILLUMINATION PER NEC 700.16 AND 700.17, LIFE SAFETY CODES. PROVIDE SCREW TYPE, LOCK ON DEVICE AT BREAKER. . NONSALES AREA EMERGENCY/NIGHT LIGHT/EXIT GIRGUIT: ALL NON SALES AREA EMERGENCY LIGHTS, NIGHT LIGHTS, AND EXIT LIGHTS SHALL BE CONNECTED TO UNSWITCHED LEG OF LOCAL LIGHTING CIRCUIT. FIXTURES ARE TO PROVIDE CONTINUOUS EGRESS AND EMERGENCY ILLUMINATION PER NEC 700.16 AND 700.17, LIFE SAFETY CODES. PROVIDE SCREW TYPE, LOCK ON DEVICE AT BREAKER. 10. LIGHTING: MOUNT LIGHTING FIXTURE CENTERED ABOVE LAVATORY PLATFORM . 11. DOWNL IG1-4T ORI ENTAT I ON : ALL DOWNLIGNTS SHALL BE IN ORIENTED IN THE SAME DIRECTION. REFER TO DOWNLIG-IT CONFIGURATION DETAIL 'K' ON SWEET 9.0 FOR MORE INFORMATION. 12. EM ONLY FIXTURES: RUN UNSWITCHED LEG OF CIRCUIT TO EMERGENCY BALLAST AND SWITCHED LEG OF. CIRCUIT TO NORMAL BALLAST, TO ALLOW FIXTURE TO BE SWITCHED. MAKE FINAL CONNECTIONS PER MANUFACTURERS WIRING DIAGRAMS. OWNER: C h 11215 METRO FT. MYERS, I C O PARKWAY FL. 33966 ' * A OA LIGWTOLIER #8037 6" CALGULITE CFL OPEN DOWNLIGHT. (1) 26W/32W/42W TRIPLE TUBE HORIZONTAL LAMP WITH CLEAR IRIDESCENCE FREE, NHITE FLANGE AND HANGER BARS. PHILIPS PLT42W /30 /4P ALTO 48 WATTS A EM /NL ®A EM /NL LIGI- ITOLIER #8037 8" CALCULITE CFL OPEN DOWNLIGHT. (1) 26W/32W/42W TRIPLE TUBE HORIZONTAL LAMP WITH CLEAR IRIDESCENCE FREE, WHITE FLANGE WITH TEST SWITCH AND HANGER BARS. PHILIPS PLT42W /30/4P ALTO 48 WATTS ARCHITECT / ENGINEER: o E o 8 CL -2 EM /NL 4' I MERCURY SURFACE MOUNTED 1 -LAMP 4' STRIP FLUORESCENT 120V, MM232 -OCT/ 4T- G- ELB -EL PHILIPS (2,) F32T8/TL830 /ALTO LAMP (3K) 90 MINUTE EMERGENCY LIGHT, BALLAST BODINE 550 OR , EQUIVALENT. (1350 LUMENS) WHEN INDICATED 32 WATTS 1 CL-2 Y Y v o U 0 0 N N y w .5 3 o 14 1 CL -2 E M /NL CL -1 EM * MERCURY #M105- 1- 32- OCT -A -P- ELB- UNI -EMPK /1320 SURFACE MOUNTED 2 -LAMP 4' LOW PROFILE WRAPAROUND 32 WATTS `�_ -- _-=— -WHITE FINISH WITH PRISMATIC ACRYLIC DIFFUSER. PHILIPS - (2) F32T8 /TL830 /ALTO LAMPS. CL -1 EM FIXTURES MARKED EM HAVE 90 MINUTE BATTERY BACKUP BALLAST (1350 LUMENS). PD -1 ��� �� PD -1 DELUX #4608 PENDANT 14 SHADE CLUSTER (14) 25W LAMPS 350 WATTS V) CO- o CO ' SC -1 TROY LIGHTING - #KB14182; 9 -1/4" N x 18 -1/2" H x 10" P BLACK MATTE FINISH - USES 3 60W CANDELABRA LAMPS 180 WATTS SC -2 n iy�1 TROY LIGHTING - #4600 POLISPED NICKEL SCONCE N/ BLACK SHADE (1) 40W LAMP 40 WATTS TRACK JUNO SINGLE CIRCUIT TRACK. NHITE - -- CV _ O * T1 8' JUNO # T690WH - 25N FRONT LOAD GIMBAL RING PA38. LABELED WITH '25 WATT MAXIMUM LAMP' PHILIPS (1) CDM1- 25W /PAR38 /FL /3K(25 DEG FLOOD) 26.4 WATTS ai ,n .L E 0 y v EX -2 r� G EX -2 EDGE- LIT LED EXIT SIGN W /90 MINUTE BATTERY BACK UP AND TEST SWITCH. CEILING MOUNT. MODEL ASTRAL: TE #IRG WHITE < 5W PER SIDE c N iO �� C • • m LV V ,� -C c v N ,0 `1' c Lcf) � (1) m +; THE ENGINEER ASSUMES NO RESPONSIBILITY OR LIABILITY FOR THE USE OF THESE PROJECT OTHERTHAN SPECIFICALPYAUTHOR ANY ED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL. THIS BUILDING USE IS ONLY APPLICABLE AREAS M ETINGTHE STATED DESGNCRITERIA N EX -3 LIGHTALARMS THERMOPLASTIC LED EXIT SIGN W/ 90 MINUTE BATTERY BACK -UP. WHITE W/ RED LETTERS. MODEL #QLXN500. WALL MOUNTED. < 5SIDEPER L N EX -3 LIGHTING SCHEDULE. NOTES: OTHERWISE SHOWN LAMP BASED ON . GENERAL CONTRACTOR SHALL VERIFY QUANTITIES OF FIXTURES AND LAMPS ON LIGHTING AND POWER PLAN. 2. ALL FIXTURES SI-IALL BE FURNISHED BY TENANT, INSTALLED AND WIRED BY GENERAL CONTRACTOR. 3. CAPITOL LIGHTING IS RESPONSIBLE FOR FINAL LIGHTING QUANTITIES. 4. WALL MOUNTED EXIT LIGHTS TO BE MOUNTED AT 12" ABOVE DOOR HEADER UNLESS NOTED IN PLANS OR ELEVATIONS. 5. LIGHTS WITH -EM /NL INDICATE LIGHTS TO BE WIRED AS EMERGENCY/NIGHT LIGHT. I *I INDICATES THAT MANUFACTURER'S LABEL. MUST BE AFFIXED STATING THAT THE WATTAGE 15 THE MAXIMUM LAMP WATTAGE THAT GAN BE USED FOR THIS FIXTURE, LIGHTING ENERGY CODE ISSUES. JO-MCZ INTIMATES STORE NO: 5381 PROJECT LOCATION: WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL SPACE NO.: 116 TUKWILA, WA 98188 LIGHTING FIXTURE SCHEDULE L LIGHTING PLAN GENERAL NOTES G C DESIGN TYPE: LINEN & LACE LIGHTING PLAN CODED NOTES ( #) ADJACENT TENANT REVISIONS: N.I.G. — — — -- REQUIRED BY: DATE I_ ADJACENT LAVATORY INGFRI Nr -- 12 ) t �_ / r'i�V ICr►.v�tl.yOi COMPLI�Ir WITH IF!'� ° Ovw >.a' 8 2012 NOV 1 E N\ _E U�, 4 "- -1 (3) Ti FIXTURES ON (21) Ti FIXTURES ON 3' -0'I OF T TRACK 25' -q" OF T TRACK--\ , 4 )CII) ' A -2B ,: ® r N 7 25' -9" 1 - o C 7) m (TYP.) (7) Ti FIXTURES ON 9' -2 "± OF T TRACK 1- Imo ( 2 ) 8 )(TYP.) - II EF -I 10 _ 1 T 1 �l.} (4EM ) v NON -SALES I FR r 1 I A _ .A > A -- q WDICATESNO REVISION TO THIS SHEET cTENANT ; M /NL N N v1 u �, /NL A -25 (q) TI FIXTURES ON (5) T1 FIXTURES ON 9' -0" OF T TRACK 5' -0" OF T TRACK- 9I -o" i 5' -O" _ r A -13 CItj10fi TIiCWIOc'� �/ c DI V ISI ®� ) _ SC -2© 6 B�ILQIN� CHECKED BY: RAP N ;, /A SC -1 '} I 01 �- �1 ) (4) T1. FIXTURES _ N o o _ Q'y — IFR -1 0 Cs, N. PRA . o1, , tja F' "� 1� 16 i v1 . , 1 t4 ■ ; I =' `� 11pi1 I,� AO n1 f 43084 r " SYirw t W t(! N �' - 1 A -29 A -24 A A-24 ON 3' -O" OF I �r N x �I _ T TRACK �; I SALES I ��" _ N I N , N I I m ® q Tu -� 1 PD -I PD -1 4/A (q) Ti FIXTURES ON (5) TI FIXTURES ON EM /NL q' -0" OF T TRACK 51-01' OF T TRACK � — _ iT ° —� ' �i s ; i 9 -0 51-0" 4A EM U N I I U 0 , V iI SC -2 A 9 (TYP.) IFR A _. A -33 - -- ti .., -30 (TYP.) N 1A N d'= Nz N u w ` >�1 I _ q' -2 " ±` T : A -I1 I � � I -- I W,j EX -3 r� 4/A ( 2 ) -A V A FITTING RM LOUNGE - A /NL - - _M EM /NL (21) T1 FIXTURES ON - FIXTURES ON OF TRACK TRA } A - ©EM Li i A -31 /NL 25' -01" OF T TRACK- DRAWING TITLE: TL LIGHTING PLAN AND FIXTURE SCHEDULE ci 3'70" •r- 25' -q' (TYP) ,�O _. -._; - - -- :. >. , m P :; L_, 8 I WALLWAY i13W 1 w I'�A ALCOVE` (TYP) I 1, .._ L -2 EM /NL FIXTURES C 6 EM /NL - EM /NL a ON 3' -On I I ' 4 0'9- OF T TRACK C 14 ` DATE ISSUED: 11/07/2012 SERVICE CORRIDOR N.I.G. - - -- ------------- - - - - -- ----- - - - - -- - PROJECT NO: 120421 -- - - - - - - -- - - RECEIVED_ ,. - CITY OF TUKLA NORTH NOV 1,9 2012 e DRAWING NO PERMIT CENTER \-\.;) 2•0 LIGHTING PLAN 1 i4° = �� -o° NOTE: GENERAL CONTRACTOR TO PROVIDE AND INSTALL CAT MOUNTING HEIGHT TO CENTERLINE MOUNTING HEIGHT TO CENTERLINE SYMBOL DESCRIPTION UNLESS NOTED OTHERWISE SYMBOL DESCRIPTION UNLESS NOTED OTHERWISE i OWNER: chico's 11215 METRO PARKWAY FT. MYERS, FL. 33966 ARCHITECT / ENGINEER: g g BE NEATLY VOLTAGE CLEARLY . CABLE AS REQUIRED COILED CONTRACTOR ON BOTH j NEAR TOP ENDS. T IN CONNECTION. T CONDUIT. OF TELEPHONE PROVIDE LABEL j BOARD ALL T 10 CABLE FEET GABLE FOR LOW `� 1. DRAWING TUBE (BY GENERAL CONTRACTOR). 2. SURFACE MOUNT JACK FOR TRAFFIC COUNTER AND CAT 5E CABLES PER PLANS. (BY GENERAL CONTRACTOR). 3. WALL MOUNT SHELF FOR ROUTER. (BY TENANT). 4. SURFACE MOUNT JACK FOR REGISTERS AND GAT 5E GABLES PER PLANS. (BY GENERAL CONTRACTOR). 5. QUADRUPLEX RECEPTACLE AND 120V DEDICATED CIRCUIT FOR TELEPHONE BOARD EQUIPMENT. (BY GENERAL CONTRACTOR). 6. QUADRUPLEX RECEPTACLE AND 120V DEDICATED CIRCUIT FOR UNIVERSAL POWER SUPPLY. (BY GENERAL CONTRACTOR). 7. TERMINATE AND LABEL ON BOTH ENDS TELEPHONE LINES ONTO 66 STYLE BLOCK. (BY GENERAL CONTRACTOR). 8. ROUTER. (BY TENANT). 9. INCOMING CAT 5E TELEPHONE LINES PER PLANS LABEL BOTH ENDS. (BY GENERAL CONTRACTOR). 10. WIRELESS ACCESS POINT DATA CONNECTION. TWO SURFACE MOUNTED JACKS AND GAT 5E CABLES PER PLANS. (BY GENERAL CONTRACTOR). 11, 4'1AIx8'1- 1x3 /4 "D PLYWOOD TELEPHONE BACKBOARD PAINTED WITH TWO COATS OF FIRE RETARDANT PAINT. (BY GENERAL CONTRACTOR). 12. TIME CLOCK TO BE MOUNTED AND LABELED ( "TIMECLOCK TC -1 ") ON TELEPHONE BOARD. (BY GENERAL CONTRACTOR). 13, UNIVERSAL POWER SUPPLY. (BY TENANT) 14. SURFACE MOUNT TELEPHONE JACK FOR REMOTE TELEPHONE LINES 1 AND 2 CAT 5E CABLES PER PLANS. (BY GENERAL CONTRACTOR). DUPLEX RECEPTACLE, 3 WIRE GROUND TYPE 18" • LOW VOLTAGE PUSH BUTTON 48" DUPLEX RECEPTACLE, CEILING MOUNTED - -- 0/ COMBINATION BUZZER /BELL AS REQUIRED �Wp DUPLEX RECEPTACLE, WEATHERPROOF I6" 4g) GFI GROUND FAULT PROTECTED DUPLEX RECEPTACLE 18" 4 DOUBLE DUPLEX (QUAD) RECEPTACLE is" CEILING MOUNTED OCCUPANCY SENSOR - -- /I O KP / LOW VOLTAGE TRANSFORMER AS REQUIRED SPEAKER - -- INTRUSION DETECTION SYSTEM KEYPAD AND ANNUNCIATOR AS REQUIRED \ WIRELESS ACCESS POINT (WAP) Y U U N N W u? 0 o ® (HUBBELL DUAL TECHNOLOGY HBA# ATD500C) F FIRE ALARM MANUAL PULL STATION 48" WALL MOUNTED OCCUPANCY SENSOR 44" (HUBBELL HBA# ADI277W1) FIRE ALARM AUDIO /VISUAL SIGNAL. DEVICE SO $1,,1p TOGGLE SWITCH, WEATHERPROOF 48" V FIRE ALARM SPEAKER VISUAL SIGNAL DEVICE 80" LINE VOLTAGE THERMOSTAT 48 FIRE ALARM AUDIO SIGNAL DEVICE 80" a DH MAGNETIC DOOR HOLDER VIA FIRE ALARM SYSTEM 48" [Sl ELECTRIC PANEL - SURFACE MOUNTED 61-0" TO TOP 1 r o co 0 ID ❑ 0 E. m = °m © ( q -( 8 ) 17 1 ( 10 13 ) 4 ETHERNET I, �, �'I LINE 3 ® ��� FAGP FIRE ALARM CONTROL PANEL AS REQUIRED 1Q ELECTRIC PANEL - FLUSH MOUNTED 6 -0 TO TOP C = O CD WAP 1•_ -, — 1 0i ®® �REG'S I SAFETY SWITCH - �i (NON FUSED) AS REQUIRED FAAP FIRE ALARM SYSTEM REMOTE ANNUNCIATOR PANEL AS REQUIRED ( 12 © I- N ZT SAFETY SWITGN (FUSED) AS REQUIRED 5� DUCT MOUNTED SYSTEM SMOKE DETECTOR WITH REMOTE INDICATORS /RESET ai IS Lo ,� Iv ( 6 ) ►Z� CI-1 M MP ® TC 3 -PHASE MAGNETIC MOTOR STARTER AS REQUIRED © SYSTEM CEILING MOUNTED SMOKE DETECTOR - -- COMBINATION STARTER /SAFETY SWITCH AS REQUIRED FS FIRE ALARM WATER FLOW SWITCH AS REQUIRED MANUAL MOTOR STARTING SWITCH AS REQUIRED TS FIRE ALARM TAMPER SWITCH AS REQUIRED MANUAL MOTOR STARTING SWITCH WITH PILOT LIGHT AS REQUIRED REMOTE ALARM /TEST SWITCI -I FOR DUCT DETECTOR AS REQUIRED MOTOR - 1 PHASE AS REQUIRED SD O CAMERA (SECURITY DOME) CEILING MOUNTED MOTOR - 3 PHASE AS REQUIRED sT SHOPPER TRACK CEILING MOUNTED TIME CLOCK AS REQUIRED 0 THERMOSTAT /SENSOR --- TELEPHONE OUTLET 18" COMBINATION TELEPHONE /DATA OUTLET 18" DATA OUTLET IS °1 `� 'p) T LL m V D ? p -a in :Ln E vj N iiii .1 M co U) w THE ENGINEER ASSUMES NO RESPONSIBILITY OR LIABILITY PROJECT OTHER THAN SPECIFICALLY AUTHORIZED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCAnoNIN THE STATE SHOWNONTHE SEAL. THIS BUILDING USE IS ONLY APPLICABLE IN AREAS MEETING THE STATED DESIGN CRITERIA. t (NI i 11 11 a m 1' - { 7 ) . LINE I LINE 1 ( 16 ) ®® ` 15. SIX PLUG SURGE PROTECTOR. (BY GENERAL CONTRACTOR). 16. SMART BOX AND PUNCH BLOCK. BY TELEPHONE COMPANY). ( ) 17. VOICE CONNECTION SURFACE MOUNT JACK FOR LINE 3 - ETHERNET AND CAT 5E CABLES PER PLANS. (BY GENERAL CONTRACTOR) lign ��� 14 SPACE F1ID ADT SYSTEM, (BY TEN) ������ 1 REVIEWED FOR � COMPLIANCE WITH NPPA70 - NEC NOV 2 8 2012 (1/�%�%' lit.(/ �../ INTIMATES ( 5 11 ( ) STORE NO: 5381 IMO PROJECT LOCATION: WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL SPACE NO.: 116 TU KW I LA, WA 98188 -- City Of�TUkWlla BUILDING DIVISION TECHNOLOGY DETAIL AND ELECTRICAL SYMBOLS C DESIGN TYPE: LINEN & LACE CODED NOTES c # ) L CENTER OF CAN LIGHT 2 - #22 AWG 21 ( 3 REVISIONS: DUPLEX OUTLET (IG) �� REQUIRED BY: DATE CAMERA DVR / LOCKBOX (SECURITY DOMES) (WALL MOUNTED) \ LIGHTING FIXTURE TYPE 'A' Pi rai, DIMENSIONED ON ARCI- IITECTURAL REFLECTED CEILING PLAN. LAMP PLUG TOWARDS STOREFRONT CONTROL CABLES # / 2 22 AWG MONITOR /FLAT SCREEN (WALL MOUNTED) 1- Ln q. I& A -31 I SALES AREA A -26 A -28 1 SALES AREA DOWNLIGHTS AND FITTING ROOM DOWNLI ITS CONTACTOR 'G2 1 SALES AREA TRACK LIGHTS, PENDANT LIGHTS AND WALL SCONCE LIGHTS MS MS KEYBOARD 1" CONDUIT UP o m r��� DOWNLIGHT5, AND FITTING ROOM LOUNGE LIGHTS ■'.■ `INDICATES NO REVISION TO THIS SHEET DIRECTION TO REAR OF STORE �� _ DIRECTION TO FRONT OF STORE TO STRUCTURE ONE ANALOG \ KEYBOARD SHELF FLOOR IDCPI ? TELEPHONE LINE FOR OUT- DIALER DRAWN BY: KMD CHECKED BY RAP POWER CONTACTORS AND TGI FROM CIRCUIT A -23 CONTACTOR 'CI' CONTROLLED BY TIMECLOCK 1. GENERAL PROVIDE CONTRACTOR TO EXTEND CABLE TO PROPOSED HEAD END EQUIPMENT LOCATION. ENOUGH EXCESS CABLE TO REACH ANY WALL IN BACK ROOM. COIL AND MARK CABLE AS CCTV. HEAD END EQUIPMENT LOCATION MUST BE WITHIN 10' OF THE 'NETWORK SWITCH ACCESS'. 2. FOR CAMERAS (SECURITY DOMES), GENERAL CONTRACTOR TO PROVIDE 18 -2 PLENUM WHITE CABLING WITN RG5R COAX PLENUM WHITE. COIL 15' -20' OF CABLING AT EACH CAMERA LOCATION FOR CONNECTIONS. FINAL CONNECTIONS BY EQUIPMENT PROVIDER. 3. GENERAL CONTRACTOR TO PROVIDE BNC CONNECTORS, PLENUM CRIMP -ON AT CAMERA LOCATIONS ONLY. BNC CONNECTORS NOT NEEDED AT THE HEAD END EQUIPMENT LOCATION. FINAL CONNECTIONS BY EQUIPMENT PROVIDER. lt'" ' ) t' ;' 'lft/,y „�4+.''�' '� , ' � +� 430`' `47;(4 ��r 'G ;, 0 ; �. STOREFRONT RECEPTACLES A -7 STOREFRONT SIGN A -q SHOW WINDOW TRACK LIGHTS A -11 • EXTERIOR WALL SCONCES DOWNLIGHT CONFIGURATION K INTRUSION DETECTION SYSTEM DETAIL F CCTV SYSTEM AND CODED NOTES B A -13 4 POLE CONTACTOR NORMALLY OPEN, ELECTRICALLY HELD CLOSED. ROUTER (BY TENANT) WEATHERPROOF PUSHBUTTON SEE POWER PLAN SHEET E1,0 FOR EXACT LOCATIONS, EDWARDS #852. SALES EDBUZZER W ARDS AT #66G0SH r 4u7b Ri� �,, t' +�'� - ,t " ��;- 4t.0 '"" �/f `t(0elk Z■ SEE CODED NOTE 6 , ON SHEET E2.0 FOR MORE INFORMATION. POWER CONTACTOR FROM CIRCUIT A -23 THRU SWITCH 'c' ® SEE ARCHITECTURAL REFLECTIVE CEILING PLAN SHEETS AND ASSOCIATED DETAILS. p \ CONNECT TO NEAREST 12OV, GONVENIENGE RECEPTACLE GIRGUIT. A -24 A PENDANT LIGHTS SALES AREA TRACK LIGHTS (. o o�� 24V EEG. DRAWING TITLE: ELECTRICAL DETAILS AN D SYMBOLS -25 SALES AREA TRACK LIGHTS A -2q -30 WALL SCONCES iJ , km NON -SALES BUZZER. EDWARDS #660. -120V TO 24V SYSTEM TRANSFORMER IN NEMA I A SPARE . O O —t� SPARE 6 POLE CONTACTOR NORMALLY OPEN, ELECTRICALLY HELD CLOSED. SEE REAR OF STORE CODED NOTE ©, ON SHEET E2.0 FOR MORE INFORMATION POWER FEED SHALL BE TOWARDS REAR OF STORE AND SHALL EXTEND PAST OF THE OUTERMOST STANDARD ENCLOSURE. EDWARDS #5q2. GENERAL NOTES: DATE ISSUED: 11/07/2012 • ROUTE CONDUIT UP IN WALL OR COLUMN TO CEILING SPACE. • RUN WIRE ABOVE CEILING IN CONDUIT WHERE REQUIRED BY CODE. REcEIVED CITY OFTUKWILA • PARALLEL WIRE BUZZERS. 1;y 2012 NOV L1 `'" PERMIT CENTER PROJECT NO 120421 OF EACH DISPLAY SECTION. CASH -WRAP STATION DRAWING NO: 3 0 LIGHTING CONTROL DETAIL N TRACK LIGHT ALIGNMENT DETAIL J DATA LAYOUT CONFIGURATION DETAIL E DELIVERY BUZZER SCHEMATIC DETAIL A • PROVIDE PULL STATIONS AS SI -101AIN ON E1.0 AND TIE INTO TENANT'S FIRE ALARM PANEL. PROVIDE DUCT MOUNTED SMOKE DETECTORS AND TIE INTO TENANT'S FIRE ALARM PANEL. FURNISH' AND INSTALL CEILING MOUNTED SMOKE DETECTOR ABOVE FIRE ALARM PANEL AND TIE INTO TENANT'S FIRE ALARM PANEL. FIRE ALARM PANEL. SEE SHEET E1.0 FOR LOCATION A -40 SEE FIRE ALARM NOTE ON SHEET El .0. FIRE ALARM RISER NOTES: FURNISH AND INSTALL SPEAKER /STROBE ANNUNCIATOR DEVICES AS SHOWN ON DRAWING E1.0 7 GENERAL CONTRACTOR SHALL CONTRACT WITH MALL APPROVED FIRE ALARM CONTRACTOR FOR FINAL CONNECTION TO LANDLORD SUPPLIED JUNCTION BOX FOR TENANT FIRE ALARM SYSTEM. VERIFY. EXACT LOCATION OF JUNCTION BOX W ITH MALL OPERATIONS MANAGER. 1. SEE PLANS OF THE TENANT (E1.0) FOR ACTUAL NUMBER OF DEVICES AND ADDITIONAL NOTES. 2. ALL MATERIALS SHALL BE NEW AND BEAR UL LABELS. 3. SUPPLY SHOP DRAWINGS FOR FIRE ALARM SYSTEM TO LOCAL AUTHORITY FOR APPROVAL PRIOR TO I NSTALLATI ON. 4. FURNISH AND INSTALL ALL LABOR AND MATERIALS REQUIRED FOR A COMPLETE INSTALLATION AS INDICATED. 5. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NEC, NFPA, STATE AND LOCAL CODES. FIRE ALARM SEQUENCE OF OPERATION: 1. ACTIVATION OF THE DUCT SMOKE DETECTOR SHALL SEND AN ALARM SIGNAL DIRECTLY TO LANDLORD CENTRAL ADDRESSABLE, VOICE EVACUATION TYPE' MAIN FIRE ALARM PANEL WHICH SHALL: A. INITIATE AN ALARM SIGNAL AT TENANT'S PANEL AND LANDLORD'S MAIN FIRE ALARM PANEL. B. SHUT DOWN TENANT'S HVAC SYSTEM C. INITIATE MALL'S HORN /STROBES. D. ACTIVATE THE TENANT ZONE SMOKE CONTROL EXHAUST SYSTEM AND THE MALL OUTSIDE AIR SUPPLY. E. NOTIFY LOCAL FIRE DEPARTMENT OF FIRE EMERGENCY LOCATION. 2. UPON SMOKE DETECTION IN DUCT MOUNTED SMOKE DETECTOR (IF APPLICABLE), FIRE ALARM PANEL SHALL: A. SHUT DOWN HVAC UNIT B. SEND A SIGNAL TO FIRE ALARM PANEL, SO THAT THE SEQUENCE LISTED ABOVE MAY BE STARTED. MECHANICAL FEEDER /CONNECTION SCHEDULE ITEM VOLTAGE HP KW M.C.A. FEEDERS TYPE OF CONN BRANCH BREAKER WIRE COND WATER HEATER INSTANT- AN SOUS 208V, 1P1-1 . ___ 4'2 ___ 2 #12 TI-II-IN 1 #12 G „ 1/2" EMT 'AC' TOGGLE SWITCH 20A -2P RTU -1 208V 3PH , - -- 154 85.20 3 #3 TH-4N 1 #8 G I I/4" EMT THRU UNIT DISC. SWITCH 100A -3P FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THE CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR TENANT PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN H15 BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR TENANT AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT THE CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. TI-4E CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR TENANT OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. GENERAL CONTRACTOR SHALL BALANCE CONNECTED WATTAGE ACROSS ALL THREE PHASES TO +/- 7% AFTER ALL CONNECTIONS ARE MADE AND RUNNING. PROVIDE BALANCE SHEET TO CONSTRUCTION MANAGER AT PUNCI- ILIST. VERIFY ALL REQUIREMENTS WITH LANDLORD AND LOCAL POWER COMPANY PRIOR TO BID. INCLUDE IN BID THE COST OF ALL WORK REQUIRED FOR A FULLY OPERATIONAL ELECTRICAL SERVICE SYSTEM INCLUDING BUT NOT LIMITED TO AIC RATINGS, FEEDER SIZE, METER REQUIREMENTS, UPGRADE OF LANDLORD'S EQUIPMENT, CONDUIT, ETC. FIRE ALARM RISER DIAGRAM AND NOTES ELECTRICAL EQUIPMENT DATA LANDLORD TO PULL NEW 120/208V SERVICE TO SPACE LANDLORD LEASE LINE SOMA TENANT SPACE I % NEW EQUIPMENT 'EXISTING EQUIPMENT J -BOX SIZED PER NEC CEILING LANDLORD PROVIDED CONDUIT AND CONDUCTORS TO THE SPACE AND GENERAL CONTRACTOR TO EXTEND TO NEW PANELBOARD. LANDLORD SHALL PROVIDE MASTER METERING EQUIPMENT. GC TO COORDINATE WITH LANDLORD /UTILITY COMPANY LANDLORD PROVIDED MAIN CIRCUIT BREAKER WITHIN THE LANDLORD'S ELECTRICAL ROOM 0\200A O / (4) 3/0 ANG. TI-41-4N, I #6 AWG. GROUND D/ AND 1 #6 ISOLATED GRD IN 2 "C. PANEL ,A' 120/205V. 3PH, 4W, 200A MCB 42 CIRCUIT 7-- TIME CLOCK AND LIGHTING CONTACTORS. SEE LIGHTING CONTROL CONNECTION DIAGRAM, DETAIL 'N' ON SHEET E3.0. ALL DISCONNECT SNITCHES AND PANELS SHALL BE INSTALLED ON PLYWOOD BACKERBOARDS. RISER DIAGRAM GENERAL NOTES: A. HVAC CIRCUIT BREAKERS TO BE "I -IACR" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. B. BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT, UNDER LOAD CONDITIONS, TO t7% BETWEEN PHASES: A /B, 5/C, C/A REGARDLESS OF CIRCUITING INDICATED. C. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL 'EQUIPMENT. D. MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. E. ALL CONNECTIONS TO LANDLORD'S SERVICE EQUIPMENT SHALL BE AS DIRECTED BY LANDLORD'S SITE REPRESENTATIVE. TENANT GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TERMINATION EXPENSES. F. SYSTEM SHALL BE GROUNDED TO THE MAIN BUILDING'S GROUNDING SYSTEM. DIST. APPROX. 150' -O" TENANT GENERAL CONTRACTOR SHALL MAKE APPLICATION TO THE (MALL /LOCAL UTILITY) FOR AN ELECTRIC METER AND A METERED ELECTRIC SERVICE IN THE TENANT'S NAME. TENANT GENERAL CONTRACTOR SHALL CONFIRM ALL LOCAL UTILITY GUIDELINES AND REQUIREMENTS PRIOR TO BID, SHALL INCLUDE THE COSTS OF THESE REQUIREMENTS IN TI-IE BID, AND SHALL COMPLY WITH THEM DURING CONSTRUCTION. APPLICATION FOR A TEMPORARY ELECTRIC METER AND CONVERSION TO A PERMANENT ELECTRIC METER SHALL BE SUBMITTED TO THE UTILITY UPON AWARD OF CONTRACT. INSTALLATION AND PROVISIONS FOR SAME SHALL COMMENCE WITHIN THE FIRST WEEK OF CONSTRUCTION. FLOOR Panel Wiring Panelboard Panel Type NEMA Type Schedule (3- phase) °A" Voltage Mains Mount ng 120/208 Phase Mains Rating Options 3 Wire AIC Rating Note 4 4.768 NQ 200A MCB 225 A 10,000 Enclosure 1 SURFACE 6.675 SHOW WINDOW LIGHTING `* 0.439 3.800 19 ' x 200w / FT 3.800 Ckt. No. Zone/ Note Load Description Equip # Brkr Opts Brkr Size* Actual KW Phase Actual KW Brkr Size* Brkr Opts Equip # Load Description Zone/ Note Ckt. No. 1 IG CASH REGISTER 125% OF LARGEST - - -- 20/1 0.280 A 0.540 20/1 - -- LOAD OF THE 220 -43 REQUIREMENT 220-43 REQUIREMENT LARGEST MOTOR & NEC x 1000 NON SALES RECEPTACLES 2 3 IG CASH REGISTER - - -- 20/1 0.280 B 0.180 20/1 - - -- SALES RECEPTACLES 4 5 UTILITY RECEPTACLE - - -- 20/1 0.720 C 0.360 20/1 - -- SALES RECEPTACLES 6 7 TC SHOW WINDOW RECEPTACLE - - -- 20/1 0.360 A 0.180 20/1 - -- . SALES RECEPTACLES 8 9 TC STOREFRONT SIGN - - -- 20/1 1.200 B 0.180 20/1 - - -- SALES RECEPTACLES 10 11 TC SHOW WINDOW LIGHTING 4 20/1 0.439 C 0.180 20/1 - -- LOUNGE AREA RECEPTACLE 12 13 TC EXTERIOR WALL SCONCES - - -- 20/1 0.360 A 0.800 20/1 - - -- REFRIGERATOR 14 15 WATER HEATER - - -- 20/2 2.100 B 0.500 20/1 - -- TELEPHONE BOARD IG 16 17 " - - -- 20/2 2.100 C 0.500 20/1 --- SOUND SYSTEM IG 18 19 MICROWAVE - - -- 20/1 0.800 A 0.500 20/1 - -- WATER COOLER 20 21 SPARE - - -- 20/1 0.000 B 0.500 20/1 - - -- SECURITY SYSTEM IG 22 23 T/C CONNECTION - - -- 20/1 0.200 C 0.700 20/1 - - -- PENDANT LIGHTS C 24 25 C SALES TRACK LIGHTS 10 20/1 1.109 A 0.192 20/1 - - -- SALES DN LIGHTS B 26 27 SPARE - - -- 20/1 0.000 B 0.192 20/1 - - -- FITTING RM DN LIGHTS B 28 29 A SALES/LOUNG DN LTS - - -- 20/1 0.288 C 0.790 20/1 - - -- WALL SCONCES C 30 31 C SALES TRACK LIGHTS 9 20/1 1.003 A 0.000 20/1 - - -- SPARE 32 33 NON SALES LIGHTS L 20/1 0.566 B 0.360 20/1 - - -- MANAGER'S DESK IG 34 35 SALES/EM/NL LIGHTS L 20/1 0.480 C 0.180 20/1 - - -- BACKWRAP RECEPTACLE IG 36 37 RTU -1 - -- 100/3 10.224 A 0.180 20/1 - - -- HVAC RECEPTACLE 38 39 " - - -- " 10.224 B 0.500 20/1 UR FIRE ALARM CIRCUIT 40 41 " - - -- " 10.224 C 0.000 20/1 - - -- SPARE 42 Notes * All circuit breakers to be 20 -Amp, 1 -Pole unless Actual Load Totals: Ph. A Ph. B Ph. C Total (All Phases to be balanced to within otherwise 16.528 noted. kw kw kw kw Actual 137.5 A A A A Zone /Note Zone - Lighting Notes - IG Breaker Options required by L - Handle lock -on device G - Ground Fault Circuit Interrupt. H - Heating, NC & Refrigeration R - Indicates Red circuit breaker as NEC 760.41 (B) Control Zones = Isolated Ground Circuit 16.782 139.6 17.161 142.7 50.471 140.3 7% using Load Totals.) 120/208V ELECTRICAL LOAD SUMMARY SYSTEM SYSTEM DESCRIPTION ACTUAL CONNECTED KW /KVA N.E.C. CONNECTED KW /KVA N.E.C. DEMAND FACTOR N.E.C. DEMAND KW /KVA LIGHTING 4.768 4.768 1.25 5.960 TRACK LIGHTING * ** 2.112 6.675 89 ' x 150W / 2FT 6.675 SHOW WINDOW LIGHTING `* 0.439 3.800 19 ' x 200w / FT 3.800 RECEPTACLES 4.220 4.220 1.0< 10 KW + 0.5 REMAINING KW 4.220 ELECTRIC WATER HEATER 4.200 4.200 1.0 4.200 MISCELLANEOUS 4.060 4.060 1.0 4.060 HVAC SYSTEM * 30.672 30.672 125% OF LARGEST 30.672 TOTAL 50.471 58.395 FT OR ACTUAL CONNECTED) FT OR ACTUAL CONNECTED) ALREADY /KVA TOTAL AMPERAGE AMPS 59.587 NOTES LOAD OF THE 220 -43 REQUIREMENT 220-43 REQUIREMENT LARGEST MOTOR & NEC x 1000 TWO CATAGORIES (200VA / (150VA/2 OR COMPRESSOR CONNECTED KW = MINIMUM FEEDER 165.6 * USE GREATER ** NEC ARTICLE * ** NEC ARTICLE * * ** 125% OF THE INCLUDED IN ACTUAL N.E.C. DEMAND KVA SYSTEM VOLTAGE x IT 59.587 x 1000 208 x 1.73 REVIEWED FOt COMPLIANCE WITH NFPA70 - NEC NOV 2 8 2012 City of-Tukwila BUILDING DIVISION L1)HO88 ELECTRICAL RISER DIAGRAM AND NOTES J PANEL SCHEDULES AND LOAD SUMMARIES Eli' D. CITY 0 TUKW LA NM 19 2012 PERMIT CENTER OWNER: chico's 11215 METRO PARKWAY FT. MYERS, FL. 33966 ARCHITECT / ENGINEER: SHREMSHOCK info @shremshock.com www.shremshock.com CO CO ce w 0 U � O N y v c D Lr) C W U z° t EjLO 0 T THE ENGINEER ASSUMES NO RESPONSIBILITY OR LIABILITY FOR THE USE OF THESE PLANS FOR ANY PROJECT OTHER THAN SPECIFICALLY AUTHORIZED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL. THIS BUILDING USE IS ONLY APPLICABLE IN AREAS MEETING THE STATED DESIGN CRITERIA. INTIMATES STORE NO: 5381 PROJECT LOCATION: WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL SPACE NO.: 116 TUKWILA, WA 98188 DESIGN TYPE: LINEN & LACE REVISIONS: REQUIRED BY: DATE INDICATES NO REVISION TO THIS SHEET DRAWN BY: KMD CHECKED BY: RAP DRAWING TITLE: ELECTRICAL PANEL SCHEDULES AND RISER DIAGRAM DATE ISSUED: 11/07/2012 PROJECT NO: 120421 A DRAWING NO: E4.0 26 05 00 COMMON WORK RESULTS FOR ELECTRICAL A. THE FOLLOWING TERMS SHALL APPLY TO ALL WORK DONE UNDER THIS CONTRACT: 1. ANY REFERENCE TO TENANT OR TENANT'S CONSTRUCTION MANAGER OR FURNISHED BY ANY OF THE ABOVE REFERS TO WHITE HOUSE BLACK MARKET. 2. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATIONS SECTIONS, APPLY TO THIS AND TI-4E OTHER SECTIONS OF DIVISION 26 THROUGH 28. 3. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF THIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT 15 TI-415 CONTRACTOR'S RESPONSIBILITY TO PROVIDE THIS SUBCONTRACTORS WITN A COMPLETE SET OF BID DOCUMENTS. 4. THIS CONTRACTOR 15 RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS WORK AND THE WORK OF T1-415 SUBCONTRACTORS TO COMPLY WITH 71-4E WHITE HOUSE BLACK MARKET SCHEDULE AND THE PROJECT COMPLETION DATE. 5, THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTOR'S BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 6. REFER TO RESPONSIBILITY SCHEDULE ON THE ARCHITECTURAL DRAWINGS FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. B. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL NEW COMPLETE ELECTRICAL SYSTEM AS INDICATED ON DRAWINGS, AS REQUIRED BY CODE AND AS SPECIFIED HEREIN, IN SECTIONS 26 05 00 THROUGH 28 31 11. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING: 1. TEMPORARY SERVICE AS REQUIRED. 2. PRIMARY DISTRIBUTION BY ELECTRIC COMPANY. 3. EMERGENCY AND EXIT LIGHTING SYSTEMS. 4, EMPTY CONDUIT TELEPHONE AND DATA SYSTEMS AS SHOWN ON THE DRAWINGS. 5. ELECTRICAL PANEL AND BRANCH CIRCUIT WIRING. 6. WIRING DEVICES AND PLATES. 7. LIGHTING FIXTURES AND LAMPS, INSTALLATION AND WIRING. 8, LIGHTING CONTROLS. q, ELECTRICAL CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS, SIGNS, CORNICE LIGHTING, CASE LIGHTING, ETC., AS SHOWN ON DRAWINGS. 10. INSTALLATION OF CONDUIT FOR SOUND SYSTEM AS SHOWN ON DRAWINGS. 11. SMOKE /FIRE ALARM WIRING, DEVICES AND CONDUIT, AS SHOWN OR DESCRIBED ON DRAWINGS OR AS NECESSARY TO MEET LANDLORD, STATE, LO GA L , INSURANCE AN D F I RE DEPARTMENT REQUIREMENTS. 12. INSTALLATION OF CONDUITS STUBBED TO ABOVE CEILING FOR HVAC, ALSO, ANY ADDITIONAL CONDUIT FOR HVAC CONTROL EQUIPMENT WHERE PLENUM RATED CABLES ARE NOT PERMITTED. THE GENERAL CONTRACTOR SHALL PAY FOR ALL ELECTRICITY PRIOR TO STORE MERCHANDISING, AND INCLUDE COST IN BID. C. WORK WHICH SHALL BE PERFORMED BY OTHERS, UNLESS NOTED OTHERWISE, INCLUDES THE FOLLOWING: 1. TEMPERATURE CONTROL WIRING THAT IS FURNISHED BY OTHERS PRE -WIRED IN UNITS. 2. TELEPHONES AND FINAL CONNECTION OF WIRING THERETO. 3. DATA LINES WIRING. 4. INTERNAL WIRING OF EQUIPMENT FURNISHED AND PRE -WIRED BY OTHERS. 5. SECURITY SYSTEM FURNISHED AND INSTALLED BY SECURITY CONTRACTOR. D. ELECTRICAL EQUIPMENT FURNISHED BY OTHER TRADES OR BY TENANT AND SPECIFIED IN OR SHOWN ON CONTRACT DOCUMENTS SHALL BE INSTALLED AND CONNECTED BY GENERAL CONTRACTOR, EXCEPT AS OTHERWISE NOTED. PROVIDE BRANCH CIRCUIT CONNECTIONS TO ELECTRICALLY OPERATED EQUIPMENT FURNISHED BY OTHERS AS SPECIFIED IN OR SHOWN ON THE CONTRACT DOCUMENTS. TEMPORARY WIRING FOR OTHER CONTRACTORS SHALL BE INSTALLED BY TI-4E GENERAL CONTRACTOR WHO SHALL BE ENTIRELY RESPONSIBLE TO THE TENANT FOR THE SAFE AND SATISFACTORY OPERATION OF SAID TEMPORARY WIRING. CONTRACTOR REQUIRING SUCH TEMPORARY WIRING SHALL PAY FOR ALL DAMAGE TO PROPERTY RESULTING FROM ITS USE. COMPLY WITH LATEST REQUIREMENTS OF OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA). PROVIDE PERSONNEL GROUND FAULT PROTECTION ON ALL TEMPORARY POWER AND LIGHTING CIRCUITS 30 AMPERES OR LESS. GROUND FAULT CIRCUIT INTERRUPTERS ON CONSTRUCTION CIRCUITS ARE NOT REQUIRED WHERE CIRCUIT IS A PERMANENT CIRCUIT TO BE A PART OF THE COMPLETED BUILDING. HOWEVER, CONTRACTOR SHALL PROVIDE APPROVED CORD SETS INCORPORATING GFCI PROTECTION FOR PERSONNEL. SEE LOCALLY ADOPTED EDITION OF T1-4E N.E.G. ALL FINISH PAINTING IS TO BE PERFORMED BY GENERAL CONTRACTOR EXCEPT THAT THIS CONTRACTOR SHALL RESTORE TO ORIGINAL CONDITION ANY PAINTING DEFACED BY THIS GENERAL CONTRACTOR AFTER ORIGINAL PAINTING. E. F. G. H. GENERAL CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY TENANT'S CONSTRUCTION MANAGER AND THE LANDLORD. PATCHING IS TO BE "AS NEW CONDITION" ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. THIS CONTRACTOR 15 RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. ANY ACCESS PANELS REQUIRED, BUT NOT SPECIFIED OR SHOWN ON DRAWINGS, SHALL BE FURNISHED BY GENERAL CONTRACTOR WITH DESIGN TO BE APPROVED BY ARCHITECT BEFORE STARTING INSTALLATION. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH 15 NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT NHICH IS NECESSARY TO COMPLETE THE WORK OR WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF CONTRACT. 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH: I. THE NATIONAL ELECTRICAL CODE. 2. STATE, CITY, AND COUNTY BUILDING CODES AND ORDINANCES, 3. NATIONAL BOARD OF FIRE UNDERWRITERS. 4. CERTAIN CODES AND STANDARDS AS SET UP BY VARIOUS TECHNICAL SOCIETIES SUCH AS UL, NEMA, NECA, IEEE, ASTM, IES, IPCEA, AND ANSI. 5. THIS WORK SHALL BE GOVERNED ALSO BY LOCAL INSPECTOR'S REQUIREMENTS. 6. FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT STANDARDS. 7. AMERICANS WITH DISABILITIES ACT. J. GENERAL CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY TENANT TO THE CONTRACTOR. K. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES, THE LANDLORD OR TENANT CRITERIA, THE CONTRACTOR 15 RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITN THE MOST STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS NOTED OTHERWISE. L. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, STATE AND LOCAL CODES, NH1CHEVER IS MORE STRINGENT. M. ALL PERMITS REQUIRED BY LAWS, ORDINANCES AND BUILDING CODES" HAVING JURISDICTION SHALL BE OBTAINED AT PROPER TIME BY AND AT THE EXPENSE OF THE GENERAL CONTRACTOR. N. ALL ELECTRICAL WORK SHALL BE INSPECTED BY THE GOVERNMENTAL AGENCY HAVING JURISDICTION, INCLUDING LOCAL INSPECTION AUTHORITIES. 0. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING, THROUGH SHOP DRAWING SUBMITTAL PROCESS, BY TENANT'S CONSTRUCTION MANAGER PRIOR TO ACCEPTANCE. THE, USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. P. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO TENANT'S CONSTRUCTION MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW SEVEN (7) WORKING DAYS FOR TENANT'S CONSTRUCTION MANAGER'S REVIEN WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL CONTRACTOR AND /OR SUB - CONTRACTOR SHOWING THAT THEY HAVE REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. Q. FOR ANY PHASED STORE CONSTRUCTION, THIS CONTRACTOR IS TO INCLUDE IN THIS SID ALL NECESSARY ELECTRICAL SERVICE CHANGES REQUIRED TO KEEP THE OPERATING PHASE OF THE STORE'S ELECTRIC SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE WITH TENANT'S CONSTRUCTION MANAGER AND LANDLORD (IN WRITING) ONE WEEK PRIOR TO ANY SHUT DONN OF THE P.O.S., CASH REGISTERS, ELECTRICAL, TELEPHONE OR FIRE ALARM SYSTEMS. ADVISE GENERAL CONTRACTOR AND TENANT AT TIME OF BID IF ANY CONFLICTS EXIST. R. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK. COORDINATE ANY EXISTING EQUIPMENT TO BE LEFT INTACT AND ADVISE TENANT'S CONSTRUCTION MANAGER AT TIME OF BID. 5. THIS CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING CONDUIT, FIRE ALARM SYSTEM, SWITCH GEAR, PITCH POCKETS AND EQUIPMENT, ETC. UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY NITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, CONDUIT AND SNITCH GEAR PRIOR TO REMOVAL. PITCH POCKETS SHALL BE REMOVED AND THE ROOF PATCHED, AS REQUIRED BY THE LANDLORD. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF /WALL/ FLOOR PATCHED /REPAIRED TO LIKE NEW CONDITION. EXISTING ABANDONED CONDUIT OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE, ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL NHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT, IF REQUIRED BY LANDLORD OR CODES, ABANDONED CONDUIT MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN PROPOSAL. T. GENERAL CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WI71 -I CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. G V. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL CONDUIT, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. N. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, WIRE, UNISTRUT, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. X. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO OTHER CONDUIT OR PIPING. HANGERS UPPER ATTACHMENT MUST BE SUPPORTED FROM THE TOP OF THE BAR JOIST. HANGING FROM METAL DECK IS NOT PERMITTED. WHERE INTERFERENCES OCCUR, 1N ORD ER TO SUPPORT CO THE CONTRACTOR MUST INSTALL TRAPEZE EZE TYPE HANGERS OR SUPPORTS WHICH SHALL B LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, JUNCTION BOXES, ACCESS DOORS, OTHER EQUIPMENT SERVICE REQUIREMENTS AND /OR OTHER TRADES. HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO LANDLORD CRITERIA. Y. UPON COMPLETION OF THE WORK, GENERAL CONTRACTOR SHALL FURNISH TO THE ARCHITECT A BEFORE OF INSPECTION AND APPROVAL FROM THE ABOVE DEPARTMENT BEF REF FINAL PAYMENT ON CONTRACT WILL BE ALLOWED. Z. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND GROUNDS BEFORE ANY EQUIPMENT IS CONNECTED. NHEN DIRECTED BY ARCHITECT, DEMONSTRATE BY PROPER VOLTAGE MEGGER TEST OF INSULATION RESISTANCE OF ANY CONDUCTORS AND REPLACE ALL CONDUCTORS WHICH FAIL SAID TESTS UNTIL ALL CONDUCTORS ARE FREE FROM INSULATION FAULTS. AA. ELECTRICAL LAYOUTS ARE SCHEMATIC. EXACT LOCATIONS ARE DETERMINED BY EXACT LOCATION OF EQUIPMENT, ETC., AND MAY BE REVISED TO SUIT THE CONSTRUCTION CONDITIONS AND AID IN COORDINATION WITH WORK OF OTHER CONTRACTORS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE TENANT'S CONSTRUCTION MANAGER IN WRITING OF ANY VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF THE BID. OTHERWISE, TENANT'S CONSTRUCTION MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED, AB. ELECTRICAL DRAWINGS ARE INTENDED TO INDICATE APPROXIMATE LOCATIONS OF SWITCHES, RECEPTACLES, LIGHTING FIXTURES AND OTHER ITEMS OF VARIOUS ELECTRICAL SYSTEMS, OF PROJECT. EXACT LOCATIONS AND ROUGH -IN DIMENSIONS FOR ALL WORK AND EQUIPMENT SHALL BE OBTAINED FROM ARCHITECT OR ARCHITECT'S REPRESENTATIVE AS WORK PROGRESSES. SHOULD THE GENERAL CONTRACTOR FAIL TO PROPERLY OBTAIN SUCH LOCATIONS OR DIMENSIONS, THE ARCHITECT SHALL CHANGE THIS WORK AT THE GENERAL CONTRACTORS EXPENSE WHEN REQUESTED BY ARCHITECT. ARCHITECT RESERVES THE RIGHT TO MAKE MINOR CHANGES IN LOCATION OF ELECTRICAL WORK OR EQUIPMENT PRIOR TO ROUGHING IN WITH NO ADDITIONAL COST TO TENANT. TENANT'S CONSTRUCTION MANAGER RESERVES TINE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. AC. THE ARCHITECT RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ANY ITEM NHICH, IN THIS OPINION, SHALL NOT PRESENT AN ORDERLY OR REASONABLY NEAT OR WORKMANLIKE APPEARANCE, PROVIDED THAT SUCH ITEM CAN BE PROPERLY INSTALLED IN SUCH ORDERLY WAY BY METHODS USUAL IN SUCH WORK, OR WHICH DOES NOT COMPLY WITH CONTRACT DRAWINGS OR SPECIFICATIONS. SUCH REMOVALS OR REPLACEMENTS SHALL BE DONE BY CONTRACTOR WHEN 50 DIRECTED IN WRITING BY ARCHITECT AND AT CONTRACTOR'S EXPENSE. AD. GENERAL CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS 1. LOCATION OF JUNCTION BOXES AND RECEPTACLES. 2. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. 3. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. AE, AT COMPLETION OF PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT B7 SIGNATURE THEREON, ONE COPY OF DRAWINGS STAMPED "DO NOT REMOVE" SHALL BE PLACED IN DRAWING TUBE LOCATED NEXT TO THE ELECTRICAL PANELS (SEE ARCHITECTURAL DRAWINGS FOR LOCATION). A SECOND AS -BUILT SET SHALL BE SENT TO CHICO'S OFFICES. AF. THE MATERIALS AND EQUIPMENT INSTALLED IN THE WORK SHALL MEET THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND NO MATERIALS OR EQUIPMENT SHALL BE ORDERED UNTIL REVIEWED BY ENGINEER. AG. GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS PER THE DOCUMENTS PROVIDED BY THE TENANT /CONTRACTOR. AN. MANUFACTURER'S CATALOG CUTS MAY BE SUBMITTED FOR STANDARD CATALOG LIGHTING FIXTURES AND OTHER EQUIPMENT. CATALOG CUTS MAY BE MARKED UP TO MEET THE PROJECT SPECIFICATIONS. CUTS SHALL BE MARKED TO INDICATE MODEL NUMBER, SIZE, TYPE, COLOR, RATING, ETC., OF THE ITEM TO BE FURNISHED. Al. PROVIDE INSTRUCTION TO TENANT'S OPERATING PERSONNEL AS NECESSARY, SHOWING LOCATIONS AND PROPER OPERATION OF MAJOR ITEMS OF EQUIPMENT AND SYSTEM COMPONENTS AND REFERRING TO THE OPERATING INSTRUCTION MANUAL DESCRIBED BELOW AS A GUIDE. A.J. GENERAL CONTRACTOR SHALL GUARANTEE T1-415 WORKMANSHIP AND MATERIALS, EXCEPT FOR TENANT- SUPPLIED MATERIALS, FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY TENANT'S CONSTRUCTION MANAGER /ENGINEERING MANAGER AND LEAVE THIS WORK IN PERFECT ORDER AT COMPLETION. AK. SHOULD DEFECTS DEVELOP WITHIN GUARANTEE PERIOD, GENERAL CONTRACTOR SHALL, UPON NOTICE OF SAME, REMEDY SUCH DEFECTS AND HAVE DAMAGES TO OTHER WORK OR FURNISHINGS CAUSED BY DEFECTS. OR WORK OR CORRECTIONS TO SAME REPAIRED AND /OR REPLACED AT TI-115 EXPENSE TO CONDITION BEFORE SUCH DEFECTS OR DAMAGE. AL. COMPILE TWO (2) WRITTEN MANUALS OF OPERATING INSTRUCTIONS INCLUDING COPIES OF SHOP DRAWINGS AND A LISTING OF EQUIPMENT SUPPLIERS. ASSEMBLE IN 8 -I/2" X 11" HARD BACKED INDEXED BINDER. MATERIAL SHALL BE AS FOLLOWS: 1. TITLE PAGE: TITLE OF JOB, LANDLORD, WHITE HOUSE BLACK MARKET ADDRESS, DATE OF SUBMISSION, CONTRACTOR, AND ENGINEER. 2. INDEX 3. LIST OF MAJOR EQUIPMENT USED IN PROJECT ACCOMPANIED BY CONTRACTOR PURCHASE ORDER NUMBERS AND SUPPLIERS' NAMES AND ADDRESSES. ONE COPY OF EACH SHOP DRAWING GROUPED BY TYPES OF EQUIPMENT, I.E., LIGHTING FIXTURES, PANELBOARDS, ETC. SECTION FOR EACH SYSTEM, INCLUDING: a. BRIEF DESCRIPTION OF SYSTEM OPERATION WITH LOCATION OF MAJOR COMPONENTS. b. LIST OF ITEMS IN SYSTEM REQUIRING PERIODIC SERVICE. REQUIRES SEPARATE SECTION FOR EACH OF: ELECTRICAL DISTRIBUTION SYSTEM . FROM THE SERVICE ENTRANCE TO EACH LIGHTING AND POWER PANEL AND OTHER SYSTEMS (I.E. CONTROL SYSTEMS AND ANY OTHER GENERAL CONTRACTOR SYSTEM LISTED IN THESE SPECIFICATIONS.) AM. WHITE HOUSE BLACK MARKET SHALL PROVIDE A COMPLETE 12 -MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT PROVIDED BY TENANT AND TENANT'S VENDORS. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONIES SHOULD BE INCLUDED IN THE BID. AN. AT THE END OF THE PROJECT, THIS CONTRACTOR 51-1ALL CLEAN ALL EQUIPMENT, INCLUDING LIGHT FIXTURES, TO THE SATISFACTION OF NHITE HOUSE BLACK MARKET. ALL DUST, DIRT, DEBRIS, PAINT AND FOREIGN MATTER SHALL BE REMOVED FROM ALL EQUIPMENT. 26 05 19 LOW VOLTAGE ELECTRICAL POWER CONDUCTORS A. CONDUCTORS SHALL BE COPPER. UNLESS NOTED OTHERWISE ON THE DRAWINGS; THE MINIMUM COPPER WIRE SIZES FOR WET AND DRY AREAS AS DEFINED BY THE N.E.C. SHALL BE AS FOLLOWS: 20 AMP CKT BKR OR FUSE _ #12 AWG, THHN /THWN 30 AMP CKT BKR OR FUSE = #10 AWG, TI-41-1N/T1-INN 40 AMP CKT BKR OR FUSE _ #8 ANG, THHN /THWN 50 AMP CKT BKR OR FUSE _ #8 AWG, THHN /THWN 100 AMP CKT BKR OR FUSE = #3 AWG, THHN /THWN 125 AMP CKT BKR OR FUSE = #1 AWG, THHN /THWN 200 AMP CKT BKR OR FUSE _ #3/0 AWG, THHN /THWN MINIMUM WIRE SIZES FOR 20A BRANCH CIRCUITS SHALL BE ADJUSTED FOR DISTANCE, MEASURED FROM THE PANELBOARD CIRCUIT BREAKER TO THE FURTHEST OUTLET, AS FOLLOWS: LESS THAN 100 FT - #12 BETWEEN 101 AND 150 FEET - #10 BETWEEN 151 AND 250 FEET #8 OVER 251 FEET #6 CONDUCTORS USED FOR EMERGENCY LIGHTING CIRCUITS SHALL BE #10 AWG, MINIMUM, AND SHALL BE RUN IN SEPARATE CONDUIT USED FOR NO OTHER PURPOSE. CONDUCTORS MAY BE STRANDED FOR SIZES #10 AWG AND LARGER. CONDUCTORS SIZE #12 AND SMALLER SHALL BE SOLID (NOT STRANDED). ON ALL 20 AMP BRANCH CIRCUITS, CONDUCTORS LARGER THAN #10 AWG SHALL BE REDUCED TO #10 ANG WITHIN 10 FEET OF PANELBOARD AND DEVICES IN JUNCTION BOXES ON RATED TERMINAL STRIPS. 8. ALUMINUM CONDUCTORS ARE NOT PERMITTED. C. THE FOLLOWING COLOR CODE SHALL BE USED: PHASE A PHASE B PHASE C NEUTRAL GROUND ISOLATED GROUND 208/120 VOLT BLACK RED BLUE WHITE GREEN GREEN/ YELLOW STRIPE D. CIRCUIT BREAKER /FUSE AND WIRE SIZE COMBINATIONS NOT SHOWN THE ENGINEER PRIOR TO INSTALLATION. ABOVE SHALL BE APPROVED BY 26 05 26 GROUNDING AND BONDING A. FURNISH AND INSTALL A COMPLETE GROUNDING SYSTEM IN COMPLIANCE WITN ALL REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE. B. A SEPARATE EQUIPMENT GROUNDING CONDUCTOR, MINIMUM SIZE PER NEC TABLE 250.122, SHALL BE INSTALLED IN CONDUIT ALONG WITH ALL FEEDERS, BRANCH CIRCUITS AND CONTROL CIRCUITS. CONDUCTOR INSULATION SHALL BE GREEN. C. CONDUIT SYSTEM SHALL BE ELECTRICALLY CONTINUOUS. ALL ENCLOSURES AND NON - CURRENT CARRYING METALS TO BE GROUNDED. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. NHERE ENCLOSURES AND NON - CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. D. ALL RECEPTACLES SHALL SE BONDED TO A GROUND CONDUCTOR USING A #12 AWG MINIMUM BONDING JUMPER BETWEEN RECEPTACLE TERMINAL AND GROUND CONDUCTOR. METAL -TO -METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE FOR EITHER R SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. E. THE GROUNDING ELECTRODE CONDUCTOR FOR SEPARATELY DERIVED SYSTEMS, SUCH AS DRY -TYPE TRANSFORMERS, 51-IALL BE RUN IN NON - METALLIC (PVC) CONDUIT TO MINIMIZE GROUND IMPEDANCE. F. LIGHTING FIXTURES SHALL BE GROUNDED BY THE USE OF A PIGTAIL FASTENED ON BARE METAL THAT I5 FREE OF PAINT. G. BOND ALL STRUCTURAL STEEL TO EARTH, GROUND RODS OR PLATES, OR WATER SYSTEM. H. BOND ALL ROOF MOUNTED EQUIPMENT TO N.E.G. ACCEPTABLE GROUNDS ONLY. 26 05 29 DISTRIBUTION A. GENERAL CONTRACTOR SHALL FURNISH ALL LABOR, MISC. MATERIALS AND EQUIPMENT NECESSARY TO INSTALL ALL OF THE ELECTRICAL SERVICE FROM THE LANDLORD'S ELECTRICAL SERVICE ROOM INCLUDING (AS INDICATED ON SWEET E4.0) BUT NOT LIMITED TO THE SECONDARY CABLES, CONDUIT, PULL WIRE AND GROUND ROD AND SLEEVE AS REQUIRED. COORDINATE REQUIREMENTS WITH LANDLORD PRIOR TO BID. THE GENERAL CONTRACTOR SHALL COORDINATE INSTALLATION OF THE DISCONNECT SWITCHES AND PANELBOARD WITH THIS WORK. B. ALL CONDUCTORS SHALL BE COPPER. ALUMINUM CONDUCTORS ARE NOT PERMITTED. C. COORDINATE WORK PROVIDED BY LANDLORD PRIOR TO BID AND INCLUDE THE COST OF ANY SUCH WORK AS DIRECTED BY LANDLORD. WIRING OF METERING EQUIPMENT SHALL BE BY GENERAL CONTRACTOR AS DIRECTED BY THE ELECTRIC COMPANY. D. METERING EQUIPMENT SHALL BE FURNISHED BY GENERAL CONTRACTOR AND INSTALLED TO THE MALLS REQU IREMENTS. E DISCONNECT SWITCHES 514ALL BE HEAVY -DUTY TYPE, UL LISTED. F. DISCONNECT SWITCHES SHALL BE BY SQUARE D, SIEMENS, CUTLER HAMMER, OR GENERAL ELECTRIC. G. ALL SWITCHES SHALL HAVE SWITCH BLADES NH1CH ARE FULLY VISIBLE IN THE "OFF" POSITION WHEN THE SWITCH DOOR IS OPEN. SWITCHES SHALL HAVE REMOVABLE ARC SUPPRESSORS WHERE NECESSARY TO PERMIT EASY ACCESS TO LINE SIDE LUGS. LUGS SHALL BE FRONT REMOVABLE AND UL LISTED FOR 75' DEGREES C., ALUMINUM OR COPPER WIRES. H. SWITCHES SHALL BE QUICK -MAKE, QUICK - BREAK. THE OPERATING HANDLE SHALL BE AN INTEGRAL PART OF THE BOX, NOT THE COVER. PROVISIONS FOR PADLOCKING THE SWITCH IN THE "OFF" POSITION WITH AT LEAST THREE LOCKS SHALL BE PROVIDED, SWITCHES SHALL HAVE A DUAL COVER INTERLOCK TO PREVENT UNAUTHORIZED OPENING OF THE SWITCH DOOR WHEN THE HANDLE 15 IN THE "ON" POSITION, AND TO PREVENT CLOSING OF THE SWITCH MECHANISM WITH THE DOOR OPEN. THE HANDLING POSITION SHALL INDICATE WHETHER THE SWITCH IS "ON" OR "OFF ". I. SWITCHES SHALL BE FURNISHED IN NEMA 1 GENERAL PURPOSE ENCLOSURE EXCEPT ALL SWITCHES LOCATED OUTDOORS SHALL BE NEMA 3R WEATHERPROOF (WP). NEMA 3R ENCLOSURE SHALL BE MANUFACTURED FROM GALVANIZED STEEL. ENCLOSURES SHALL HAVE A GRAY BAKED ENAMEL FINISH, ELECTRODEPOSITED, ON CLEANED, PHOSPHATIZED STEEL. J. SWITCHES SHALL BE RATED FOR AG. FUSIBLE SWITCHES MUST ACCEPT CLASS R FUSES AND HAVE PROVISIONS TO REJECT ALL FUSES EXCEPT CLASS R. THE UL LISTED SHORT CIRCUIT RATING OF THE SWITCHES SHALL BE 200,000 RMS SYMMETRICAL AMPERES WHEN CLASS R FUSES ARE USED. K. NAMEPLATES SHALL INDICATE FUNCTION OF EACH DEVICE. NAMEPLATES SHALL BE LAMINATED PHENOLIC WITH A WHITE SURFACE AND BLACK CORE. USE 1/16" THICK MATERIAL FOR NAMEPLATES UP TO 2 "x4" AND USE 1/8" THICK MATERIAL FOR LARGER SIZES. ALL NAMEPLATES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. GENERAL CONTRACTOR TO COORDINATE WITN THE LOCAL BUILDING AUTHORITY OR BUILDING INSPECTOR ON WHICH ITEMS SHOULD HAVE A NAMEPLATE. L. ALL FUSES SHALL BE BUSSMANN, SIZES AS NOTED ON DRAWINGS. M. ALL FUSES SHALL BE UL LISTED, CURRENT- LIMITING TYPE, MINIMUM 200,000 AMPS INTERRUPTING CAPACITY. N. FUSES 1 AMP AND ABOVE SHALL BE BUSSMANN "LOW PEAK" RK -I. 250 VOLT FUSES SHALL BE USED ON 208/120 VOLT SYSTEMS. 0. CONTROL FUSES FOR MOTOR STARTERS, CONTACTORS, AND CONTROL PANEL TRANSFORMERS SHALL BE BUSSMANN FNQ -R SIZED AT 500% RATED CURRENT. P. FURNISH SPARE FUSES TO THE TENANT IN THE FOLLOWING QUANTITIES: 10% OF TOTAL PROJECT QUANTITY (BUT NOT LESS THAN THREE (3) FOR EACH TYPE AND RATING OF FUSES). Q. TYPED LIST OF ALL SPARES SHALL ALSO BE INCLUDED. R. FURNISH AND INSTALL CIRCUIT BREAKER TYPE POWER, HEATING AND LIGHTING PANELBOARDS AS SHOWN ON THE DRAWINGS. 5. ALL PANELBOARDS SHALL BE LISTED UNDER UL 67 AND SHALL HAVE APPROPRIATE LABELING. ALL BUSSING SHALL BE SOLID COPPER. T. PANELBOARDS FOR USE ON 208Y/120V VOLT SYSTEM SHALL HAVE A MINIMUM INTEGRATED EQUIPMENT SHORT CIRCUIT CURRENT RATING OF 10,000 AMPS RMS SYMMETRICAL. EXACT RATING SHALL BE DETERMINED BY AVAILABLE FAULT CURRENT FROM UTILITY. GENERAL CONTRACTOR SHALL FURNISH PANELS BASED ON UTILITY COMPANY INFORMATION. ALL LUG CONNECTIONS SHALL BE 75.0 RATED. U. PANELBOARD FRONT ASSEMBLY SHALL INCLUDE A HINGED DOOR WITH A FLUSH MOUNTED CYLINDER LOCK TYPE SPRING LOADED LATCH. ALL LOCKS SHALL BE KEYED ALIKE. DOOR SHALL INCLUDE A TYPED CIRCUIT DIRECTORY CARD MOUNTED IN A FRAME WITH A CLEAR PLASTIC PROTECTIVE COVER. V. EACH PANELBOARD SHALL HAVE A FULL CAPACITY SOLID COPPER NEUTRAL SUBASSEMBLY. W. EACH PANELBOARD SHALL INCLUDE A SOLID COPPER GROUND BUS SUBASSEMBLY, SIMILAR IN CONSTRUCTION TO THE NEUTRAL SUBASSEMBLY, FACTORY MOUNTED AND BONDED TO THE BOX. X. EACH PANELBOARD SHALL INCLUDE (WHERE SPECIFIED) A SOLID COPPER ISOLATED GROUND BUS SUBASSEMBLY, SIMILAR IN CONSTRUCTION TO THE NEUTRAL SUBASSEMBLY, FACTORY MOUNTED AND BONDED TO THE BOX. Y. INTERIOR LABELING SHALL INCLUDE A CONNECTION DIAGRAM AND LABELS INDICATING PROPER TORQUE AND WIRE TYPES FOR MAIN INPUT CONNECTIONS AND BOTH LINE AND LOAD SIDE CIRCUIT BREAKER CONNECTIONS. Z. CIRCUIT BREAKERS SHALL BE QUICK MAKE, QUICK BREAK, THERMAL MAGNETIC TRIP (ENCLOSURE COMPENSATED), MOLDED CASE TYPE, UL LISTED. 15 AND 20 AMP SINGLE POLE BREAKERS SHALL CARRY THE UL "SND" MARKING. LINE SIDE TERMINALS SHALL BE BOLTED TO MAIN BUSBARS. BREAKER RATINGS SHALL BE PER DRAWINGS, AA. TERMINALS FOR CONNECTION OF THE FEEDER TO THE PANELBOARD MAINS TO MAIN BREAKER SHALL BE UL RECOGNIZED AS SUITABLE FOR THE TYPE OF CONDUCTORS SPECIFIED. AB. NAMEPLATES AS SCHEDULED ON DRAWINGS SHALL INDICATE FUNCTION OF EACH DEVICE. NAMEPLATES SHALL BE LAMINATED PHENOLIC WITH A WHITE SURFACE AND BLACK CORE. USE 1/16" THICK MATERIAL FOR PLATES UP TO 2" X 4 ". FOR LARGER SIZES, USE 1/8" THICK MATERIAL. AC. MANUFACTURER: GENERAL ELECTRIC TYPE AQ FOR 208Y/120V APPLICATIONS. EQUAL EQUIPMENT BY SQUARE D, SIEMENS, OR CUTLER HAMMER WILL BE ACCEPTED. AD. EACH PANELBOARD SHALL BE INSTALLED WITH TOP CIRCUIT BREAKER AT 6' -0" ABOVE FLOOR, FLUSH OR SURFACE MOUNTED. 26 05 33 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS A. FURNISH AND INSTALL OUTLET BOXES FOR ALL DEVICES AS REQUIRED, (RECEPTACLES, LIGHTING FIXTURES, MOTORS, SYSTEMS EQUIPMENT CONNECTIONS, SPECIAL OUTLETS AND AS OTHERWISE REQU IRED). B. ALL OUTLET BOXES SHALL BE GALVANIZED PRESSED STEEL OF THE STANDARD KNOCKOUT TYPE. NO ROUND OUTLET BOXES SHALL BE PERMITTED, EXCEPT AS SPECIFICALLY NOTED ON DRAWINGS, CONCEALED BOXES SHALL NOT BE LESS THAN 4" SQUARE AND 1 -1/2" DEEP, WITH PLASTER RINGS. C. ALL KNOCKOUT BOXES, UPON WHICH LIGHTING FIXTURES ARE TO BE INSTALLED, SHALL BE EQUIPPED WITH 3/8" FIXTURE STUDS. D. RECESSED OUTLET BOXES SHALL BE STAMPED STEEL SUITABLE FOR THE DEVICE INSTALLED. SURFACE MOUNTED OUTLET BOXES SHALL BE CAST IRON SUITABLE FOR THE DEVICE INSTALLED. E. EXTERIOR BOXES SHALL BE CAST RUST - RESISTING METAL WITH GASKETED COVERS. F. INSTALL BOXES RIGIDLY FROM BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF FLOORS, CEILINGS, WALLS ETC. ALL OUTLET BOXES TO BE PROVIDED WITH GADDY "QUICK-MOUNT BOX SUPPORT" TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING /UNPLUGGING INTO THESE DEVICES. G. ALL ELECTRICAL CONDUCTORS SHALL BE ENCLOSED IN CONTINUOUS GROUNDED RACEWAY SYSTEM EXCEPT AS OTHERWISE NOTED (I.E. LOW - VOLTAGE PLENUM -RATED WIRE). H. NO OTHER CIRCUITS ARE TO BE RUN IN SAME CONDUIT FEEDING ISOLATED GROUND RECEPTACLES. I. RACEWAY AND ENCLOSURE SIZES SHALL BE AS SHOWN ON DRAWINGS OR, IF NOT SHOWN, SHALL BE SIZED TO COMPLY WITH N.E.G. FILL REQUIREMENTS FOR CONDUCTORS ENCLOSED. PULL OR JUNCTION BOXES SHALL BE PROVIDED IN ALL RACEWAY SYSTEMS AT MAXIMUM OF 100 FOOT W AND INTERVALS HERE REQUIRED TO AVOID EXCESSIVE NUMBER OF BENDS, TO FACILITATE WIRE PULLING OR TO PROVIDE ACCESS TO RACEWAY SYSTEM. BOXES AND COVERS SHALL BE GALVANIZED STEEL OF CODE GAUGE SIZE. TO THE EXTENT POSSIBLE, AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. TI-4E USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. JUNCTION AND PULL BOXES MUST BE LABELED WITH CIRCUIT NUMBER IDENTIFICATION AND SYSTEM TYPE ON COVER. K. RACEWAYS AND ENCLOSURES SHALL BE ADEQUATELY SUPPORTED FROM BUILDING STRUCTURE WITH APPROVED SUPPORT RODS AND /OR CLAMPS. L. ALL CONDUIT SHALL BE RIGID HEAVYWALL GALVANIZED STEEL OR THIN NALL EMT WHERE PERMITTED BY CODE OR AS HEREINAFTER SPECIFIED. PVC SCHEDULE 50 CONDUIT MAY BE USED UNDER FLOOR SLAB. ROMEX, BX, MC OR AG, ETC., ARE NOT PERMITTED. M. MINIMUM SIZE OF CONDUIT SHALL BE 1/2" FOR INDIVIDUAL LIGHTING FIXTURE CONNECTIONS OR TO INDIVIDUAL LIGHT SNITCHES (IF ACCEPTABLE BY THE LANDLORD AND LOCAL CODE OFFICIALS) AND 3/4" FOR. ALL OTHER LOCATIONS. IF HVAC CONTROL WIRING IS REQUIRED TO BE RUN IN CONDUIT, IT SHALL BE A MINIMUM OF 1/2 ", UNLESS NOTED OTHERWISE ON DRAWINGS. ALL IN /UNDER FLOOR CONDUIT SHALL BE OF MINIMUM 1" SIZE. N. EMT THIN WALL CONDUIT MAY BE USED INSIDE HOLLOW PARTITIONS AND ABOVE SUSPENDED P ED CEILINGS AND EXPOSED ABOVE 8' -0" ABOVE FINISHED FLOOR OR ABOVE PANELBOARDS. EMT CONDUIT MAY NOT BE USED BURIED IN EARTH OR FILL, IN OR UNDER CONCRETE FLOOR OR IN POURED CONCRETE CONSTRUCTION. 0. PVC CONDUIT USED UNDER FLOOR SLABS SHALL HAVE RIGID GALVANIZED STEEL ELLS AND METALLIC CONDUIT ABOVE FLOOR SLAB. P. FLEXIBLE METAL CONDUIT (FMC) SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL CONNECTION TO RECESSED FIXTURES, MOTORS, AND ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. FMC SHALL BE UL APPROVED, AND 5011H THE CONDUIT AND FITTINGS SHALL BE LISTED FOR GROUNDING. FMC SHALL BE KEPT TO FOUR FEET (4' -0 ") MAXIMUM LENGTH AND 5HALL BE MINIMUM ONE -HALF INCH (1/2 ") ELECTRICAL TRADE SIZE. NHEN CONNECTED TO HARD CONDUIT, THE FMC MUST BE THE SAME SIZE AS THE HARD CONDUIT IT IS CONNECTED TO. AN EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED IN ALL RUNS OF FMC. Q. LIQUID -TIGHT FLEXIBLE CONDUIT (LFMC) AND LIQUID -TIGHT FITTINGS SHALL BE USED IN AREAS EXPOSED TO THE WEATHER OR EXCESSIVE MOISTURE AS THE FINAL CONNECTION TO MOTORS, AND ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. LFMG SHALL BE UL APPROVED, AND 80114 THE CONDUIT AND FITTINGS SHALL BE LISTED FOR GROUNDING. LFMC SHALL. BE KEPT TO FOUR FEET ( 4 - O n ) MAXIMUM LENGTH AND SHALL BE MINIMUM ONE -HALF INCH (1/2 ") ELECTRICAL TRADE SIZE. WHEN CONNECTED TO HARD CONDUIT, THE LFMC MUST BE THE SAME SIZE AS THE HARD CONDUIT IT IS CONNECTED TO. AN EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED IN ALL RUNS OF LFMC. R. CONDUIT SHALL GENERALLY BE CONCEALED WHERE POSSIBLE. NO CONDUIT SHALL BE RUN IN SLAB, EXCEPT AS REQUIRED FOR FLOOR- MOUNTED DEVICES. PROVIDE PROPERLY LABELED PULL STRING IN ALL EMPTY CONDUITS. 5. EXPOSED CONDUIT WILL BE PERMITTED IN ELECTRIC ROOMS, AND SIMILAR UNFINISHED SPACES, OVERHEAD IN AREAS WITHOUT CEILINGS AND ELSEWHERE AT THE DISCRETION OF THE ARCHITECT. T. ALL CONDUIT FITTINGS SHALL BE GALVANIZED MALLEABLE IRON OR STEEL. CONNECTORS AND COUPLINGS SHALL BE THREADED OR CUPPED SET SCREW TYPE, CONCRETE TIGHT. CONDUIT BODIES SHALL BE MALLEABLE IRON, THREADED FOR HEAVYWALL CONDUIT AND CUPPED SET SCREW TYPE FOR EMT, WITH CADMIUM FINISH AND CADMIUM PLATED SHEET STEEL COVERS. SYNTHETIC RUBBER GASKETS SHALL BE USED UNDER BODY COVERS EXPOSED TO WEATHER. EMT CONNECTORS SHALL BE INSULATED THROAT TYPE. U. INSTALL EXPANSION FITTINGS AT ALL LOCATIONS WHERE CONDUITS CROSS BUILDING EXPANSION JOINTS OR TRAVERSE FROM ONE INDEPENDENT STRUCTURE TO ANOTHER. INSTALL WHEREVER CONDUITS TRAVERSE STRUCTURES HAVING SEPARATE FOUNDATIONS OR WHERE EXISTING BUILDINGS ARE JOINED TO A NEW STRUCTURE. - V. DURING ROUGHING -IN, CAP ALL CONDUITS WHICH MAY BECOME FOULED WITH FOREIGN MATERIAL. W. NO MORE THAN THREE (3) q0- DEGREE BENDS WILL BE ALLOWED IN ANY ONE CONDUIT RUN. WHERE MORE BENDS ARE NECESSARY IN ANY SINGLE RUN, A PULL BOX SHALL BE INSTALLED. ALL CONDUIT EXCEPT IN CONCRETE SLAB OR EARTH SHALL BE ROUTED PARALLEL OR PERPENDICULAR TO THE LINES OF THE BUILDING, AND NO OUT -OF -PLUMB OR DIAGONAL LINES WILL BE ACCEPTED. 26 09 23 LIGHTING CONTROLS A. WHERE LIGHTING CONTACTORS ARE INDICATED ON THE DRAWINGS, THEY WILL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR COMPLETE WITH CONDUIT. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE TO INSTALL THE CONTACTORS AND PULL ALL WIRES AS DETAILED ON THESE DRAWINGS AND CIRCUITED EXACTLY AS DIAGRAMMED ON THE ELECTRICAL DETAIL DRAWINGS. NO VARIATIONS TO THE CIRCUITING ARE ALLOWED. 26 27 26 WIRING DEVICES A. INSTALL ALL WIRING DEVICES, INCLUDING SWITCHES, RECEPTACLES AND POWER RECEPTACLES, TELEPHONE OUTLET BOXES, COVER PLATES AND BLANK OUTLET PLATES AS SHOWN OR DESCRIBED ON DRAWINGS, B. UNLESS OTHERWISE NOTED ON DRAWINGS OR OTHERWISE REQUIRED BY THE NATIONAL ELECTRICAL CODE, HANDICAP CODES OR LOCAL CODES, OUTLET HEIGHTS SHALL BE AS FOLLOWS: 1. SWITCH HEIGHT 48" FROM FINISHED FLOOR TO CENTERLINE OF OUTLET. 2. CONVENIENCE OUTLETS: a. SALES: 16" FROM FINISHED FLOOR TO BOTTOM OF OUTLET. b. NON - SALES: 16" FROM FINISHED FLOOR TO BOTTOM OF OUTLET 3. TELEPHONE OUTLETS SHALL BE LOCATED AS NOTED ON DRAWINGS. C. DUPLEX RECEPTACLES SHALL BE A MINIMUM OF 20 AMPERE RATING. D. COLOR OF DEVICES AND PLATES SHALL BE WHITE, UNLESS NOTED OTHERWISE. THE DEVICES SHALL BE OF THE TYPES AND RATINGS LISTED, OR EQUALS BY ARROW - HART, GENERAL ELECTRIC OR PASS AND SEYMOUR. WEATHERPROOF GFCI RECEPTACLES SHALL BE INSTALLED WHERE SHOWN ON DRAWINGS OR AS REQUIRED BY CODE. DEVICES SHALL BE OF THE FOLLOWING SPECIFICATI tltl J� UNLESS OTHERWISE INDICATED SPECIFICALLY ON PLANS. ���� I-vl E. SINGLE POLE SWITCHES: 20AMP - 120 -277V: HUBBELL "HSL1221" THREE WAY SWITCHES: 20AMP - I20 -277V: HUBBELL "1- I13L1223" DUPLEX RECEPTACLES: 20AMP - 125V: HUBBELL "HBL5362" DUPLEX RECEPTACLES - BLACK: 20AMP - I25V: HUBBELL "1-1BL5362BLK" ISOLATED GROUND RECEPTACLES: 20AMP - 125V: HUBBELL "IG5362" GFCI RECEPTACLES: 20AMP - 125V: HUBBELL "GF5362A" FLOOR BOXES: HUBBELL "B- 2527/29 WITH S -3925 BRASS COVER" COMPLIANCE WITH NFPA 70 - NEC NOV 2 8 2012 ALL DEVICE COVER PLATES SHALL BE PASS AND SEYMOUR SERIES "RP" OR EQUAL BY EA LE City of Tukwila ELECTRIC MFG. CO. BUILDING DIVISION, OTHER EQUIVALENT DEVICES WITH MATCHING COVER PLATES MAY BE FURNISHED AS APPROVED BY ».... WHITE HOUSE BLACK MARKET. F. WIRING DEVICES, UNLESS OTHERWISE PROPERLY AUTHORIZED, SHALL BE SAME MANUFACTURERS ONLY; NO ADDITIONAL MANUFACTURERS SHALL BE PERMITTED UNLESS SPECIFICALLY AUTHORIZED BY TENANT OR TENANT'S REPRESENTATIVE. G. LON VOLTAGE CONTROL DEVICES SHALL BE AS NOTED ON DRAWINGS OR AS REQUIRED. 26 29 13 MOTOR CONTROLLERS A. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL MOTOR CONTROLS, INCLUDING STARTERS, SAFETY DEVICES AND REMOTE CONTROL STATIONS, UNLESS FURNISHED BY EQUIPMENT MANUFACTURER IN PRE -WIRED ASSEMBLIES. B. FURNISH AND INSTALL MANUAL MOTOR STARTERS WITH OVERLOAD RELAYS IN EACH LINE CONDUCTOR FOR ALL FRACTIONAL HORSEPOWER MOTORS NOT EQUIPPED NITH BUILT -IN RUNNING OVERCURRENT PROTECTION, NOT REQUIRING AUTOMATIC CONTROLLERS. C. MANUAL MOTOR STARTERS SHALL INCLUDE OVERLOAD RELAYS IN ALL LINE POLES SIZED TO TRIP SWITCH AT 125% OF MOTOR FULL LOAD RUNNING CURRENT, NEON PILOT LIGHTS, AND NEMA ENCLOSURES, AS MANUFACTURED BY GENERAL ELECTRIC, ALLEN BRADLEY, CUTLER HAMMER, SIEMENS, OR SQUARE -D. D. FURNISH AND INSTALL AUTOMATIC MOTOR STARTERS FOR ONE (1) HP OR LARGER SINGLE PHASE AND THREE PHASE MOTORS OR MOTORIZED EQUIPMENT FURNISHED WITHOUT STARTERS, REQUIRING AUTOMATIC STARTERS FOR CONTROL REGARDLESS OF HORSEPOWER RATING. ALL THREE PHASE STARTERS SHALL HAVE ANTI- SINGLE PHASING, UNDERVOLTAGE PROTECTION, AND PHASE REVERSAL PROTECTION RELAYS EITHER INCLUDED IN STARTERS OR WIRED TO STARTER CONTROL CIRCUIT. E. PROTECTIVE RELAYS SHALL HAVE ADJUSTABLE TIME DELAY RELAY IN CIRCUIT TO AVOID NUISANCE SHUT DOWNS. TIME MARK OR SIMILAR EQUIPMENT IS ACCEPTABLE, IF PROTECTION IS NOT PART OF STARTER. DO NOT RELY ON PROPERLY SIZED FUSES AND MOTOR STARTER OVERLOAD HEATERS ALONE TO AVOID SINGLE PHASING BURNOUTS. F. FURNISH AND INSTALL CONTACTORS, CONTROL RELAYS, PUSHBUTTON STATIONS, SELECTOR SWITCHES, PILOT LIGHTS, FUSES AND SIMILAR CONTROL AUXILIARIES AS SHOWN ON DRAWINGS AND /OR REQUIRED TO PROVIDE PROPER CONTROL AND ISOLATION BETWEEN VARIOUS AUTOMATIC CONTROLLERS AND EQUIPMENT SHONN ON THE DRAWINGS. G. ALL CIRCUIT BREAKERS FEEDING MOTOR LOADS SHALL BE HACR TYPE. H. EQUIPMENT SHALL BE SAME MAKE AS MOTOR STARTERS. PUSHBUTTON STATIONS, SELECTOR SWITCHES, PILOT LIGHTS: HEAVY DUTY, OIL TIGHT, STANDARD SIZE, WITN TRANSFORMER TYPE PILOT LIGHTS, FLUSH MOUNTED WHERE PRACTICAL. (ELECTRICAL SPECIFICATIONS CONTINUED ON SHEET E5.1) ELD (088 CITY' OF TUIPMIA Nov '1, 9 2012 PERMIT CENTER OWNER: chico's 11215 METRO PARKWAY FT. MYERS, FL. 33966 ARCHITECT / ENGINEER: V 0 z w 2 N info@shremshock.com o C O di N ▪ a) a CCD C▪ D C LL1 C O _c N O M co ccoo www.shremshock.com f: 614 545 4555 0 u1, 10 10 1 THE ENGINEER ASSUMES NO RESPONSIBILITY OR LIABILITY FOR THE USE OF THESE PLANS FOR ANY PROJECT OTHER THAN SPECIFICALLY AUTHORIZED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL. THIS BUILDING USE IS ONLY APPLICABLE IN AREAS MEETING THE STATED DESIGN CRITERIA. fcma INTIMATES STORE NO: 5381 PROJECT LOCATION: WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL SPACE NO.: 116 TUKWILA, WA 98188 DESIGN TYPE: LINEN & LACE REVISIONS: REQUIRED BY: DATE • INDICATES NO REVISION TO THIS SHEET DRAWN BY: KMD CHECKED BY: RAP DRAWING TITLE: ELECTRICAL SPECIFICATIONS DATE ISSUED: 11/07/2012 PROJECT NO: 120421 ELECTRICAL SPECIFICATIONS A DRAWING NO: E5.0 26 51 00 INTERIOR LIGHTING A. INSTALL LIGHTING FIXTURES AS SHOWN ON THE DRAWINGS. B. ALL FIXTURES TO BE LISTED AND LABELED BY UNDERWRITERS LABORATORIES AND ALL BALLASTS TO BE CERTIFIED BY CBM AND ETL. C. LAMPS SHALL BE MANUFACTURED BY PHILIPS, OSRAM /SYLVANIA OR GENERAL ELECTRIC. ALL LAMP TYPES SHALL BE BY THE SAME MANUFACTURER. D. FIXTURES ARE TO BE PROVIDED COMPLETE WITH BALLASTS, SOCKET, LAMPS, END AND TRIP PLATES AND ALL MOUNTING ACCESSORIES REQUIRED FOR A COMPLETE FIXTURE INSTALLATION. E. INCANDESCENT AND HIGH INTENSITY DISCHARGE RECESSED LIGHTING FIXTURES TO BE FURNISHED WITH THERMAL CUT OUTS AS REQUIRED BY THE NEC. F. USE RAPID -START 1-HGH- POWER - FACTOR ELECTRONIC BALLASTS AND T8 LAMPS, UNLESS NOTED OTHERWISE. FURNISH SPECIAL LOW TEMPERATURE BALLASTS FOR EXTERIOR MOUNTED FIXTURES. G. WHEREVER REQUIRED, HID BALLASTS TO BE REACTOR OR CWA HPF TYPE AND HIGH PRESSURE SODIUM BALLASTS TO BE REACTOR HPF TYPE. H. UNLESS OTHERWISE NOTED, ALL LENSES ON FLUORESCENT FIXTURES ARE TO BE ACRYLIC AND A MINIMUM OF 0.125 IN. THICK. I ALL RECESSED HID FIXTURES SHALL CARRY A ULR LISTING. THEY SHALL HAVE A THERMAL CUT OUT ON BOTH THE BALLAST AND THE FIXTURE ITSELF. J. USE STEEL WIRE HANGERS FASTENED TO THE BUILDING STRUCTURE TO SUPPORT RECESSED FIXTURES AT EACH CORNER. (FOUR CORNER SUSPENDED). FIXTURES TO FIT TIGHT AGAINST CONSTRUCTION TO ELIMINATE LIGHT LEAKS. K. WALL - MOUNTED FIXTURES SHALL BE MOUNTED PLUMB WITH BUILDING LINES AND INSTALLED WITH PROPER BOX AND COVER HARDWARE. L. SURFACE - MOUNTED FIXTURES SHALL COVER MOUNTING HARDWARE. USE A CANOPY THAT IS NO LONGER THAN THE LENGTH AND WIDTH OF THE FIXTURE AND AT A HEIGHT THAT IS NO HIGHER THAN REQUIRED TO MOUNT FIXTURE ABSOLUTELY VERTICAL. CANOPY FINISH SHALL MATCH FIXTURE FINISH. M. STEM- MOUNTED FIXTURES SHALL BE MOUNTED 50 AS TO BE ABSOLUTELY VERTICAL AND HORIZONTAL. INSTALL AND SUPPORT AS SHOWN ON DRAWINGS. 27 00 00 GENERAL REQUIREMENTS A. PROVIDE ALL MATERIALS, LABOR, TOOLS, TRANSPORTATION INCIDENTALS AND APPURTENANCES TO COMPLETE IN EVERY DETAIL AND LEAVE IN WORKING ORDER ALL WORK CALLED FOR HEREIN. B. ALL NEW MATERIAL AND EQUIPMENT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS: I. TELECOMMUNICATIONS INDUSTRY ASSOC. /ELECTRONIC INDUSTRIES ASSOC, (TIA /EIA): a. TI IA /EIA 568A.1, 2, AND 3 TELECOMMUNICATION CABLING STANDARD. b. TIA /EIA 569 TELECOMMUNICATION PATHWAYS AND SPACES. G. TIA /EIA 606 ADMINISTRATION OF INFRASTRUCTURE d. TIA /EIA 607 GROUNDING AND BONDING e. COMPLY WITH TIA /EIA 568, 569, AND BIC STANDARDS. f. COMPLY WITH NFPA 70. C. FURNISH NEW AND UN- DETERIORATED MATERIALS OF A QUALITY NOT LESS THAN NEAT IS SPECIFIED. ALL NEW MATERIAL SHALL HAVE MANUFACTURER'S NAME, MODEL NUMBER, OR OTHER IDENTIFICATION MARKING. D. THE CONTRACTOR SHALL BEAR ALL COSTS OF PERMITS, INSPECTIONS TESTS, AND /OR APPROVALS, E. THE CONTRACTOR SHALL PROVIDE ON -SITE PERSONNEL TO TROUBLESHOOT AND REPAIR ANY PROBLEMS THAT ARISE DURING CUTOVER AS THEY RELATE TO THEIR INSTALL-ED SYSTEM. F. AFTER COMPLETION, A WARRANTY SHALL BE FURNISHED FOR ALL COMPONENTS, PARTS, AND ASSEMBLIES AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. WARRANTY SERVICES SHALL BE PROVIDED BY A CERTIFIED, FACTORY TRAINED REPRESENTATIVE OF THE EQUIPMENT MANUFACTURER FOR A MINIMUM OF ONE YEAR OR AS SPECIFIED IN EACH INDIVIDUAL SECTION. 27 05 10 TELEPHONE AND DATA CONDUIT SYSTEM A. FURNISH AND INSTALL A SYSTEM OF CONDUIT RACEWAYS, OUTLET BOXES, PULL WIRES, AND TERMINAL BOARDS AS SHOWN ON THE DRAWINGS UNLESS OTHERWISE NOTED ON PLANS. TELEPHONE SWITCHING APPARATUS, CONDUCTORS, INSTRUMENTS, MISCELLANEOUS EQUIPMENT AND APPURTENANCES ARE NOT PART OF THIS CONTRACT AND WILL BE PROVIDED AND INSTALLED BY OTHERS. B. CONDUITS FOR TELEPHONE WALL OUTLETS AND DATA WIRING SHALL BE A MINIMUM OF 1" UNLESS NOTED OTHERWISE. C. FURNISH AND INSTALL A 3/4" THICK, FIRE - TREATED, PLYWOOD TELECOM BACKBOARD AT LOCATION SHOWN ON THE DRAWINGS. PAINT WITH FIRE RETARDANT "P -1B" OR AS DIRECTED BY TENANT'S CONSTRUCTION MANAGER. THE PLYWOOD BACKBOARD SHALL BE SECURELY ATTACHED TO THE BUILDING WALLS TO SUPPORT RELAY PANELS, TERMINAL BLOCKS' AND OTHER HARDWARE WEIGHING APPROXIMATELY 10 POUNDS PER SQUARE FOOT, D. ALL CONDUIT RUNS FOR DATA AND TELEPHONE SHALL BE CONTINUOUS WITH NO JUNCTION BOXES EXCEPT AS NOTED ON DRAWINGS. TI-41S INCLUDES BUT 15 NOT LIMITED TO RUNS BETWEEN TELEPHONE BOARD, MANAGER'S OFFICE, SOUND SYSTEM, CASHWRAPS AND TELEPHONE SETS. E. INSTALL PULL STRING IN EMPTY CONDUITS. ALL PULL STRINGS SHALL BE LABELED FOR PURPOSE DESIGNATED. F. FURNISH AND INSTALL GROUND ROD AND *6 GROUND WIRE FROM TELECOM BACKBOARD TO SERVICE ENTRANCE GROUND AND GROUND ROD PER TELEPHONE COMPANY'S REQUIREMENTS. G. OUTLET BOXES TO BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. 27 05 15 INTERIOR COMMUNICATIONS PATHWAYS A. INTERIOR COMMUNICATIONS PATHWAYS SHALL BE INSTALLED BY THE GENERAL CONTRACTOR AND BY THE TELECOMMUNICATIONS CONTRACTOR AS SPECIFIED HEREIN. B. CONDUITS SHALL BE INSTALLED, AS DETAILED IN DRAWINGS. THESE CONDUITS SHALL BE INSTALLED BY THE GENERAL CONTRACTOR. 27 05 28 WALL -MOUNT RACK A. WALL RACK SHALL CONTAIN NETWORK SWITCH, PATCH PANELS) AND BE MOUNTED ON THE WALLBOARD LOCATED IN THE BACK STORAGE ROOM. B. PROVIDE LOW ELL MODEL X -2820. WALL RACK SHALL BE INSTALLED, AS DETAILED IN DRAWINGS. 27 11 00 HORIZONTAL CABLING AND CONNECTIVITY A. PROVIDE A 10/100/1000 MBPS FULL- DUPLEX TRANSMISSION ETHERNET NETWORK OVER 4 -PAIR, CATEGORY 5E UTP HORIZONTAL CABLING. THE SYSTEM SHALL BE A CERTIFIED SOLUTION BY THE CONNECTIVITY MANUFACTURER. TI-4E HORIZONTAL INFRASTRUCTURE SHALL SUPPORT BOTH VOICE AND DATA APPLICATIONS. S. THIS SECTION INCLUDES WIRE, CABLE, CONNECTING DEVICES, INSTALLATION, AND TESTING FOR WIRING SYSTEMS TO BE USED AS SIGNAL PATHWAYS FOR VOICE, VIDEO, AND DATA TRANSMISSION. THE SYSTEM SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: 1. MOUNTING ELEMENTS 2. UNSHIELDED TWISTED -PAIR CABLE. 3. COAXIAL CABLE. 4. PATCH, STATION, AND CROSS CONNECT CORDS 5. JACKS AND FACEPLATES 6. TERMINATION AND PATCH PANELS G. MANUFACTURERS: SUBJECT TO COMPLIANCE W1TH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: I. COPPER CABLES (UTP AND COAXIAL): a. BERK -TEK, INC. b. BELDEN c. MOHAWK d. GENERAL e. UNIPRISE 2. MODULAR JACKS AND FACEPLATES: 0. LEVITON b. HUBBELL G. ORTRONI CS d. PANDUIT e. UNIPRISE D. HORIZONTAL CABLES FOR VOICE /DATA INFRASTRUCTURE: 1. LISTED AS COMPLYING WITH CATEGORY 5E OF TIA /EIA - 568 -A. 2. CONDUCTORS: SOLID COPPER. 3. UTP CABLE: COMPLY WITH T IA/El A - 568 -A. FOUR THERMOPLASTIC - INSULATED, INDIVIDUALLY TWISTED PAIR OF CONDUCTORS; NO. 2 AWG, COLOR - CODED; ENCLOSE IN A JACKET. 4. CABLE RATING: PLENUM - LISTED FOR USE IN AIR - HANDLING SPACES, 5. NON - PLENUM IN ALL OTHER AREAS. COAXIAL 6.' COLOR CODING: BLUE FOR DATA AND YELLOW FOR VOICE HORIZONTAL CABLES FOR VIDEO: 1. THE HORIZONTAL CABLES SHALL BE RATED RG -6 /U; CELLULAR POLYETHYLENE DIELECTRIC, BARE COPPER BRAID SHIELD WITH 95 PERCENT MINIMUM SHIELDING FACTOR, NO. 18 AWG SOLID COPPER CONDUCTOR; AND PVC JACKET. USE PLENUM RATED CABLE WHERE REQUIRED. F. WORKSTATION OUTLETS: SINGLE JACK CONNECTOR ASSEMBLIES MOUNTED IN FACEPLATE. 1. FACEPLATE; NIGH IMPACT PLASTIC; COLOR TO BE WHITE. 2. MOUNTING: FLUSH, UNLESS OTHERWISE INDICATED. 3, LABELING: SHALL NAVE INTEGRAL LABEL WITH LABEL COVER. 4. JACK SPACES: AS INDICATED ON THE DRAWINGS WITH ANY NECESSARY BLANKS. BLANKS SHALL MATCH FACEPLATE COVER. G. WIRING METHOD: INSTALL HORIZONTAL CABLING IN RACEWAY WITHIN RACKS AND ENCLOSURES, AND EXCEPT IN ACCESSIBLE CEILING SPACES AND IN GYPSUM BOARD PARTITIONS WHERE CABLE WIRING METHOD MAY BE USED. CONCEAL RACEWAY AND CABLING EXCEPT IN UNFINISHED SPACES. IN ACCESSIBLE CEILINGS, USE APPROPRIATELY SIZED J -HOOKS TO SUPPORT THE CABLING EVERY FOUR FEET (MAXIMUM). H. INSTALL CABLE USING TECHNIQUES, PRACTICES, AND METHODS THAT ARE CONSISTENT WITH CATEGORY 5E RATING OF COMPONENTS AND THAT INSURE CATEGORY 5E PERFORMANCE OF COMPLETED AND LINKED SIGNAL PATHS, END TO END. DO NOT BEND CABLE IN HANDLING OR IN INSTALLING TO SMALLER RADII THAN MINIMUMS RECOMMENDED BY MANUFACTURER. J. HORIZONTAL CABLES: LABEL CABLES AT THE WORK AREA END AND AT THE CLOSET END WITH THE PATCH PANEL PORT NUMBER. LABEL EACH CABLE WITHIN 3 INCHES OF EACI-I TERMINATION, WHERE IT 15 ACCESSIBLE IN A CABINET OR JUNCTION OR OUTLET BOX, AND ELSEWHERE AS INDICATED. K. WORKSTATION: LABEL CABLES WITHIN OUTLET BOXES # NEATLY TYPED ON THE INTEGRAL LABEL IN THE FACEPLATE WITH THE PATCH PANEL PORT NUMBER. L. WARRANTY PERIOD FOR COMMUNICATIONS CONNECTIVITY (INCLUDING ALL COPPER): MANUFACTURER'S STANDARD, BUT NOT LESS THAN 25 YEARS FROM DATE OF CONTRACT COMPLETION. 27 22 00 DATA NETWORK EQUIPMENT A. THE LOCAL AREA NETWORK (LAN) SHALL BE CAPABLE OF 10/100/1000 MB /S FULL DUPLEX DATA TRANSMISSION VIA 4 -PAIR CAT 5E UTP CABLE TO EVERY DATA JACK OUTLET. ALL EQUIPMENT MUST BE THE LATEST MODEL AVAILABLE AT THE TIME OF DELIVERY AND INSTALLATION. B. ETHERNET SWITCHES AND NETWORK MANAGEMENT SOFTWARE: 1. 3COM 2. CISCO 3. HP C. ETHERNET SWITCHES: 1. PROVIDE RACK MOUNTED SWITCHES. 2. SWITCHES SHALL BE RATED 10 /100 /1000 BASE -T LINE SWITCHING SPEED. (RJ -45). 3. SWITCHES SHALL HAVE TWENTY -FOUR 100BASE -T PORTS 4. SWITCH FEATURES SHALL INCLUDE, BUT NOT LIMITED TO: 0. STORE - AND - FORWARD SWITCHING b. FULL /HALF DUPLEX AUTO - NEGOTIATION G. d. e. f. 9• J. k. BACK PRESSURE FLOW CONTROL FOR HALF- DUPLEX BROADCAST STORM SUPPRESSION 802.ID SPANNING TREE PROTOCOL (STP) 802.IW RAPID SPANNING TREE PROTOCOL (RSTP) 802.10 VLAN SUPPORT 802.IP' TRAFFIC PRIORITIZATION 1802.3X FULL - DUPLEX FLOW CONTROL j802.3AD LINK AGGREGATION. IGMP Vl AND V2 SNOOPING. 5. ADVANCED QUALITY OF SERVICE: SHALL PRIORITIZE TRAFFIC TO ENSURE MAXIMUM NETWORK PERFORMANCE AND OPTIMIZE IP TELEPHONY, VIDEO, AND DATA. 6. EACH 5W ITCH SHALL SUPPORT THE FOLLOWING SNMP STANDARDS: a. ESNMP PROTOCOL (RFC1I57) b. MIB -II (RFC 1213) c. BRIDGE MIB (RFC14c13) d. RMON MIB II (RFC 2021) e. REMOTE MONITORING MIS (RC 1757) f. INTERFACE MIB (2233) STANDARDS: 7. EACH SWITCH 51-IALL SUPPORT THE FOLLOWING SECURITY a. RADIUS (RFC 2865, RFC 2869) b. SESSION ACCOUNTING (RFC 2866) c. IEEE 802.1X NETWORK LOGIN d. SSHV2. D. INSTALL ETHERNET SWITCH COMPLETE AND VALIDATE CONNECTIVITY THROUGHOUT. ESTABLISH ALL VLANS, IP ROUTING, AND IP SUBNETS PER OWNER'S DIRECTION. 28 22 00 INTRUSION DETECTION SYSTEM A. THIS SECTION INCLUDES AN INTRUSION DETECTION SYSTEM WITH A DIGITAL RECORDER FOR MONITORING AND RECORDING BUILDING ACTIVITY. B. CONTROL PANEL, MOTION SENSORS, GLASS BREAK SENSORS, KEYPADS, AND DOOR CONTACT SWITCHES: I. GE 2. HONEYWELL 3. PHI LLI PS/BOSCH C. KEYPAD STATIONS 1. KEYPAD AND DISPLAY MODULE: ARRANGED FOR ENTERING AND EXECUTING COMMANDS FOR SYSTEM STATUS CHANGE AND FOR DISPLAYING SYSTEM STATUS AND COMMAND RELATED DATA. D. MOTION SENSORS 1. CEILING OR WALL MOUNT PASSIVE INFRARED WITH A 120- DEGREE ANGLE. E. CONTROL UNITS 1. COMPLY WITH UL 1023. 2. CABINET: LOCKABLE STEEL ENCLOSURE, ARRANGED SO OPERATIONS REQUIRED FOR TESTING, NORMAL OPERATION, AND MAINTENANCE ARE PERFORMED FROM FRONT OF ENCLOSURE. IF MORE THAN A SINGLE CABINET I5 .REQUIRED TO FORM A COMPLETE CONTROL UNIT, PROVIDE EXACTLY MATCHING MODULAR ENCLOSURES. ACCOMMODATE ALL COMPONENTS AND ALLOW AMPLE GUTTER SPACE FOR INTERCONNECTING CABINETS AND FIELD WIRING. IDENTIFY EACH ENCLOSURE BY AN ENGRAVED, LAMINATED, PHENOLIC RESIN NAMEPLATE. LETTERING ON ENCLOSURE NAMEPLATE SHALL NOT BE LESS THAN 1 INCH (25 MM) HIGH. IDENTIFY INDIVIDUAL COMPONENTS AND MODULES WITHIN CABINETS WITH PERMANENT LABELS. 3. CONTROL MODULES: TYPES AND CAPACITIES AS REQUIRE TO PERFORM UNIT FUNCTIONS. VISIBLE AND AUDIBLE SIGNALS IN CENTRAL CONTROL UNIT INDICATE ALARM SUPERVISORY, AND TROUBLE CONDITIONS FOR EACH ZONE. EACI-I TYPE OF AUDIBLE ALARM HAS A DISTINCT SOUND. 4 ZONES: QUANTITY OF ALARM AND SUPERVISORY ZONES AS INDICATED WITH CAPACITY FOR EXPANDING NUMBER OF ZONES HY A MINIMUM OF 25 PERCENT. 5. POWER SUPPLY CIRCUITS: UNITS PROVIDE POWER FOR REMOTE POWER CONSUMING DETECTION DEVICES. CIRCUIT CAPACITY IS ADEQUATE FOR AT LEAST A 25 PERCENT INCREASE IN LOAD. 6. INDICATING' LIGHTS: INDIVIDUAL LED DEVICES DESIGNATE EACH ZONE. AN LED TEST SWITCH FOR EACH CONTROL UNIT SECTION ILLUMINATES ALL LED DEVICES ON THAT SECTION OF THE UNIT. MANUAL TOGGLE TEST- SWITCHES OR PUSH TEST BUTTONS DO NOT REQUIRE A KEY TO OPERATE. ALARM AND SUPERVISORY SIGNALS LIGHT A RED LED FOR THE ASSOCIATED ZONE. TROUBLE SIGNALS LIGHT AN AMBER LED FOR THE ASSOCIATED ZONE. 7. RESETTING: CONTROLS PERMIT SILENCING AUDIBLE SIGNALS FOR INDIVIDUAL ZONES BUT PREVENT RESETTING OF ALARM, SUPERVISORY, OR TROUBLE SIGNALS WHILE THE CONDITION STILL EXISTS. 8 TRANSMISSION TO REMOTE ALARM RECEIVING STATION: AUTOMATICALLY ROUTE ALARM, SUPERVISORY, AND TROUBLE SIGNALS TO A REMOTE ALARM STATION BY MEANS OF A DIGITAL ALARM COMMUNICATOR TRANSMITTER AND TELEPHONE LINES. F. DIGITAL ALARM COMMUNICATOR TRANSMITTER 1. FUNCTIONAL PERFORMANCE: UNIT RECEIVES AN ALARM, SUPERVISORY, OR TROUBLE SIGNAL FROM THE CONTROL PANEL, AND AUTOMATICALLY CAPTURES ONE OR TWO TELEPHONE LINES AND DIALS A PRESET NUMBER FOR A REMOTE CENTRAL STATION. G. CONDUCTORS AND CABLES 1. STRANDED COPPER: SIZE CONDUCTORS AS RECOMMENDED BY SYSTEM MANUFACTURER, UNLESS OTHERWISE INDICATED. H. LISTING FOR SYSTEM 1. UL 1610 - CENTRAL STATION BURGLAR ALARM UNITS. INSTALL SYSTEM ACCORDING TO NFPA 70, APPLICABLE CODES MANUFACTURER'S WRITTEN INSTRUCTIONS. J. TRAIN OWNER'S PERSONNEL A MINIMUM OF 1 HOUR IN THE USE, OPERATION, AND ADMINISTRATION. 28 31 11 DIGITAL ADDRESSABLE FIRE ALARM SYSTEM A. A NEW MICROPROCESSOR CONTROLLED FIRE DETECTION SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE SPECIFICATIONS AND DRAWINGS, AND AS REQUIRED BY THE LOCAL AUTHORITY. B. ACCEPTABLE MANUFACTURES: AVAILABLE MANUFACTURERS SUBJECT TO COMPLIANCE WITH REQUIREMENTS. MANUFACTURERS OFFERING FIRE ALARM SYSTEM THAT MAY BE INCORPORATED INTO THE WORK ARE LIMITED TO THE FOLLOWING: I. SILENT KNIGHT 2. FIRE -LITE 3. ADEMCO 4. DMP 5. BOSCH FIRE ALARM PANEL MUST BE COMPATIBLE WITH THE LANDLORD'S CENTRAL ADDRESSABLE, VOICE EVACUATION TYPE FIRE ALARM SYSTEM. C. GENERAL SYSTEM DESCRIPTION: THE SUPERVISED, CODED, CLOSED - CIRCUIT TYPE SYSTEM SHALL BE SO ARRANGED THAT PULLING A MANUAL PULL STATION OR OPERATION OF ONE OF THE AUTOMATIC DETECTING DEVICES WILL REGISTER AN ALARM AT THE FIRE ALARM CONTROL PANEL. THIS WILL CAUSE IMMEDIATE AND CONTINUOUS OPERATION OF ALL THE BUILDING ALARM SIGNALS TO SOUND THE GENERAL ALARM SIGNAL, UNTIL T1-1E ALARM HAS BEEN ACKNOWLEDGED AT THE CONTROL PANEL. D. BASIC PERFORMANCE: E. F. 1. ALARM, TROUBLE AND SUPERVISORY SIGNALS FROM ALL REPORTING DEVICES SHALL BE ENCODED ONTO AN NFPA STYLE 4 (CLASS B) SIGNALLING LINE CIRCUIT. 2. INITIATION DEVICE CIRCUITS SHALL BE WIRED CLASS B (NFPA STYLE B). 3. INDICATING APPLIANCE CIRCUITS SHALL BE WIRED STYLE Y (CLASS B). SUBMIT COORDINATED SH0P DRAWINGS TO THE ARCHITECT FOR. APPROVAL. ALL REFERENCES TO MANUFACTURER'S MODEL NUMBERS AND OTHER PERTINENT INFORMATION HEREIN 15 INTENDED TO ESTABLISH MINIMUM STANDARDS OF PERFORMANCE, FUNCTION AND QUALITY. G. THE SYSTEM MUST HAVE PROPER LISTING AND /OR APPROVAL FROM THE FOLLOWING NATIONALLY RECOGNIZED AGENCIES: I. UL, UNDERWRITERS LABORATORIES, INC. 2. NFPA 70, NATIONAL ELECTRICAL CODE (NEC).. 3. NFPA 72, NATIONAL FIRE ALARM CODE. H. MODULAR LABELING: THE FIRE ALARM CONTROL PANEL SHALL MEET THE MODULAR LISTING REQUIREMENTS OF UNDERWRITERS LABORATORIES, INC. TO FACILITATE SYSTEM CHANGES AND EXPANSIONS, AND TO ENSURE THAT ALL SUBASSEMBLIES HAVE TI-4E PROPER LISTING, EACH SUBASSEMBLY OF THE FACP SHALL CARRY THE APPROPRIATE UL MODULAR LABEL. THIS INCLUDES ALL PRINTED CIRCUIT BOARD ASSEMBLIES, POWER SUPPLIES, AND ENCLOSURE PARTS. I. ALL EQUIPMENT COMPONENTS SI -IALL BE NEW, AND TI-4E MANUFACTURER'S CURRENT MODEL. THE MATERIALS, APPLIANCES, EQUIPMENT AND DEVICES SHALL BE TESTED AND LISTED BY A NATIONALLY RECOGNIZED APPROVALS AGENCY FOR USE AS PART OF A PROTECTED PREMISES PROTECTIVE SIGNALING (FIRE ALARM) SYSTEM. TI-4E AUTHORIZED REPRESENTATIVE OF THE MANUFACTURER SHALL BE RESPONSIBLE FOR THE SATISFACTORY INSTALLATION OF TI-4E COMPLETE SYSTEM. J. ALL EQUIPMENT AND COMPONENTS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURER'S RECOMMENDATIONS. CONSU LT THE MANUFACTURER'S INSTALLATION MANUALS FOR ALL WIRING DIAGRAMS, SCHEMATICS, PHYSICAL EQUIPMENT SIZES, ETC., BEFORE BEGINNING SYSTEM 1NSTALLAT ION . K. ALL EQUIPMENT SHALL BE ATTACHED TO WALLS AND CEILING /FLOOR ASSEMBLIES AND SHALL BE HELD FIRMLY IN PLACE. L. ALL WIRING SHALL BE INSTALLED IN CONDUIT OR RACEWAY. CONDUIT FILL SHALL NOT EXCEED .40 PERCENT OF INTERIOR CROSS- SECTIONAL AREA WHERE THREE OR MORE CABLES ARE CONTAINED WITHIN A SINGLE CONDUIT. M. GABLE MUST BE SEPARATED FROM ANY OPEN CONDUCTORS OF POWER OR CLASS 1 CIRCUITS, AND SHALL NOT BE PLACED IN ANY CONDUIT, JUNCTION BOX, OR RACEWAY CONTAINING THESE CONDUCTORS. N. WIRING IN CONDUIT SHALL BE IN ACCORDANCE WITH LOCAL, STATE AND NATIONAL CODES (E.G., NEC ARTICLE 760) AND AS RECOMMENDED BY THE MANUFACTURER OF THE FIRE ALARM SYSTEM. NUMBER AND SIZE OF CONDUCTORS SHALL BE AS RECOMMENDED BY TI-4E FIRE ALARM SYSTEM MANUFACTURER, BUT NOT LESS THAN #18 AWG (1.02 MM) FOR INITIATING DEVICE CIRCUITS AND SIGNALING LINE CIRCUITS, AND #12 AWG (1.63 MM) FOR INDICATING APPLIANCE CIRCUITS. 0. ALL WIRE AND CABLE SHALL BE LISTED AND /OR APPROVED BY A RECOGNIZED TESTING AGENCY FOR USE WITH A PROTECTIVE SIGNALING SYSTEM. P. THE FIRE ALARM CONTROL PANEL SHALL BE CONNECTED TO A SEPARATE DEDICATED BRANCH CIRCUIT, MAXIMUM 20 AMPERES. FIRE ALARM CONTROL PANEL PRIMARY POWER WIRING SHALL BE #12 AWG. THE CONTROL PANEL CABINET SHALL BE GROUNDED SECURELY TO THE BUILDING GROUNDING SYSTEM. Q. FIRE ALARM CONTROL PANEL SHALL BE BY APPROVED MANUFACTURERS LISTED ABOVE, AND SHALL BE SURFACE MOUNTED WHERE INDICATED ON PLAN. PROVIDE A REMOTE ANNUNCIATOR PANEL FOR RECESS MOUNTING AT T1-4E LOCATION SHOWN ON THE PLAN. R. STROBE LIGHTS: I, SHALL OPERATE ON 24 VDC, NOMINAL. 2. SHALL MEET TI-4E REQUIREMENTS OF TI-4E ADA AS DEFINED IN UL STANDARD 1971, AND SHALL MEET THE FOLLOWING CRITERIA: 0. UNLESS OTHERWISE SPECIFIED ON THE DRAWINGS, THE INTENSITY SHALL BE A MINIMUM OF 75 CANDELA. b. ALL STROBES IN ANY GIVEN AREA SHALL BE SYNCHRONIZED WITH OTHER STROBES IN THAT AREA c. THE APPLIANCE SHALL BE PLACED 60 IN. ABOVE THE HIGHEST FLOOR LEVEL lNITHIN TI-4E SPACE, OR 6 IN. BELOW THE CEILING, WHICHEVER IS LOWER. 3. SHALL HAVE NIP ITE HOUSING WITH RED LETTERS, UNLESS PROHIBITED BY LOCAL CODES OR MALL STANDARDS. S. AUDIBLE /VISUAL COMBINATION DEVICE: I. SHALL MEET TI-4E APPLICABLE REQUIREMENTS OF SECTION 16722 -R LISTED ABOVE FOR VISIBILITY. 2. AUDIBLE SIGNAL SHALL BE 15DB ABOVE AMBIENT SOUND LEVEL. 3. SHALL HAVE NHITE HOUSING WITH RED LETTERS, UNLESS PROHIBITED BY LOCAL CODES OR MALL STANDARDS. T. MANUAL STATIONS: I. ADDRESSABLE MANUAL STATIONS SHALL BE PROVIDED TO CONNECT TO THE FIRE ALARM CONTROL PANEL SIGNALING LINE CIRCUIT (SLC) LOOPS. . 2. THE MANUAL STATIONS SHALL USE A KEY OPERATED TEST -RESET LOCK, AND SHALL BE DESIGNED 50 THAT AFTER ACTUAL EMERGENCY OPERATION, THEY CANNOT BE RESTORED TO NORMAL USE EXCEPT BY THE USE OF A KEY. 3. ALL OPERATED STATIONS SHALL HAVE A POSITIVE, VISUAL INDICATION OF OPERATION THAT CANNOT BE RESET WITHOUT THE USE OF A KEY. 4. MANUAL STATIONS SHALL BE SUITABLE FOR SEMI FLUSH MOUNTING AS SHOWN ON THE PLANS, AND SHALL BE INSTALLED NOT LESS THAN 42 INCHES, AND NOT MORE THAN 48 INCHES ABOVE THE FINISHED FLOOR. U. PHOTOELECTRIC DETECTORS: 1. THE PHOTOELECTRIC TYPE DETECTOR SHALL BE A PLUG -IN UNIT WHICH MOUNTS TO A TWIST -LOCK BASE, AND SHALL BE UL LISTED. . 2. THE DETECTORS SHALL BE OF THE SOLID STATE PHOTOELECTRIC TYPE AND SHALI- CONTAIN NO RADIOACTIVE MATERIAL. THEY WILL USE A PULSED INFRARED LED LIGHT SOURCE AND BE SEALED AGAINST REAR AIR FLOW ENTRY. 3. THE DETECTOR SHALL FIT INTO A BASE THAT IS COMMON WITH BOTH THE HEAT DETECTOR AND IONIZATION TYPE DETECTOR AND SHALL BE COMPATIBLE WITH OTHER ADDRESSABLE DETECTORS, ADDRESSABLE MANUAL STATIONS, AND ADDRESSABLE ZONE ADAPTOR MODULES ON THE SAME CIRCUIT. THE DETECTOR SHALL ALSO FIT INTO A NON - ADDRESSABLE BASE THAT 15 CAPABLE OF BEING MONITORED BY AN ADDRESSABLE ZONE ADAPTOR MODULE. 4. THE SENSOR AND BASE SHALL BE BY APPROVED MANUFACTURERS LISTED ABOVE. DUCT SMOKE DETECTORS: I. DUCT SMOKE DETECTORS SHALL BE OF THE SOLID STATE PHOTOELECTRIC TYPE AND SHALL OPERATE ON THE LIGHT SCATTERING PHOTODIODE PRINCIPLE. THE DETECTORS SHALL BE DESIGNED TO IGNORE INVISIBLE AIRBORNE PARTICLES OR SMOKE DENSITIES THAT ARE BELOW THE FACTORY SET ALARM POINT. NO RADIOACTIVE MATERIALS SHALL BE USED. W. ADDRESSABLE THERMAL DETECTOR HEAD I. THERMAL DETECTOR HEADS MUST BE UL LISTED. THEY WILL BE A COMBINATION RATE -OF -RISE AND FIXED TEMPERATURE (135 °F) TYPE, AUTOMATICALLY RESTORABLE. THE SENSOR AND BASE SHALL BE BY APPROVED MANUFACTURERS LISTED BELOW, X. AT THE FINAL INSPECTION, A FACTORY TRAINED REPRESENTATIVE OF THE MANUFACTURER OF THE MAJOR EQUIPMENT SHALL DEMONSTRATE T1• -IAT THE SYSTEM FUNCTIONS PROPERLY IN EVERY RESPECT. Y. THE CONTRACTOR AND/OR THE SYSTEMS MANUFACTURER'S REPRESENTATIVES SHALL PROVIDE A TYPEWRITTEN "SEQUENCE OF OPERATION" TO THE TENANT. Z. BEFORE FINAL APPROVAL OF THE FIRE ALARM SYSTEM 15 REQUESTED, PROVIDE THE ARCHITECT, IN WRITING, A STATEMENT THAT ALL REQUIREMENTS OF THE CITY BUILDING INSPECTION AND FIRE DEPARTMENTS HAVE BEEN MET IN THE INSTALLATION OF THE FIRE ALARM SYSTEM. AA. SUBMIT TO THE TENANT, UPON COMPLETION OF THE SYSTEM INSTALLATION, A CONTRACTOR'S FIRE ALARM SYSTEM CERTIFICATION AND DESCRIPTION FORM AS OUTLINED BY NFPA 72, AND AN APPROVED INSPECTION FORM FOR THE FIRE ALARM PORTION OF THE SYSTEM. (END OF ELECTRICAL SPECIFICATION) REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 2 8 2012 City of Tukwila BUILDING DIVISION pcej V6D. 111 I O 6 '11YOF11JK1AI0.A .-- y�� O Nov 19 2012 v PERMIT CENTER OWNER: chico's 11215 METRO PARKWAY FT. MYERS, FL. 33966 ARCHITECT /ENGINEER: SHREMSHOCK info @shremshock.com 8 0) E rn 33 THE ENGINEER ASSUMES NO RESPONSIBILITY OR LIABILITY FOR THE USE OF THESE PLANS FOR ANY PROJECT OTHER THAN SPECIFICALLY AUTHORIZED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL. THIS BUILDING USE IS ONLY APPLICABLE IN AREAS MEETING THE STATED DESIGN CRITERIA. Jama INTIMATES STORE NO: 5381 PROJECT LOCATION: WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL SPACE NO.: 116 TUKWILA, WA 98188 DESIGN TYPE: LINEN & LACE REVISIONS: REQUIRED BY: DATE • INDICATES NO REVISION TO THIS SHEET DRAWN BY: KMD CHECKED BY: RAP DRAWING TITLE: ELECTRICAL SPECIFICATIONS (CONTINUED) DATE ISSUED: 11/07/2012 PROJECT NO: 120421 ELECTRICAL SPECIFICATIONS (CONTINUED) DRAWING NO: E5.1