Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL12-1141 - WESTFIELD SOUTHCENTER MALL - CHILDREN'S PLACE
CHILDREN'S PLACE 1026 SOUThCENTER MALL EL12 -1141 City otI'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No.: 9202470010 Address: 1026 SOUTHCENTER MALL TIIKW Project Name: CHILDREN'S PLACE Permit Number: EL12 -1141 Issue Date: 01/25/2013 Permit Expires On: 07/24/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD. CA 92013 Contact Person: Name: TAMMY KORTE Phone: 314 - 415 -2400 Address: ARC VISION , 1950 CRAIG RD, SUITE 300, ST LOUIS MO 63146 Contractor: Name: AMPLE ELECTRIC GROUP INC Address: 18261 73 AV NE, APT A -303 , KENMORE WA 98028 Contractor License No: AMPLEEG889BL Phone: 206 - 359 -1249 Expiration Date: 01/12/2014 DESCRIPTION OF WORK: ELECTRICAL FOR NEW TENANT IMPROVEMENT Value of Electrical: NRES: $26,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: $674.63 2008 Date: ( 3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t perfoRnance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: ov- 60 (v,v { c Date: 1725 /2,M3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL12 -1141 Printed: 01 -25 -2013 • PERMIT CONDITIONS • Permit No. EL12 -1141 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -1141 Printed: 01 -25 -2013 CITY OF TUKWI• Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tulovila, •WA 98188 http://www.TukwilaW A. gov • Electrical Permit No. Ct_` d- ' ! 1-{, 1 Project No. ` �, — Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: Site Address: 1026 Southcenter Mall Suite Number: 155 Floor: Tenant Name: The Children's Place PROPERTY OWNER Name: Tammy Korte, ArcVision Address: 1950 Craig Rd #300 Name: Westfield Phone: (314) 415 -2400 Fax: (314) 415 -2300 Email: tkorte @arcv.com Address: 2800 Southcenter City: Seattle State: WA Zip: 98198 CONTACT PERSON — ,person receiving all project communication Name: Tammy Korte, ArcVision Address: 1950 Craig Rd #300 City: St. Louis State: MO Zip: 63146 Phone: (314) 415 -2400 Fax: (314) 415 -2300 Email: tkorte @arcv.com New Tenant: 0 Yes ❑..No ELECTRICAL CONTRACTOR INFORMATION. Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 26,000 Scope of Work (please provide detailed information): tenant improvement Will service be altered? 121 Yes ❑ No Adding more than 50 amps? ❑ Yes No Type of Use: mercantile Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms- Applications On Line\2011 Applications \Electrical Permit Application Revised 8 -9 -1 I.docx Revised: August 2011 bh O Tenant Improvement ❑ Temporary Service Page 1 of 2 • . •• • • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added /altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT. APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. I UILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: vo Print Name: Mailing Address: -Gamvv ■ u \uy \c‘451`) c . 3 °0 H:\Applications \Forms - Applications On Line\201 I Applications \Electrical Permit Application Revised 8 -9 -1 l.docx Revised: August 2011 bh Date: 1 5 1 G . ' Day Telephone: q' 11 1, -.3400 City 111W Ublqco State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL12 -1141 Address: 1026 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/06/2012 Applicant: CHILDREN'S PLACE Issue Date: Receipt No.: R13 -00551 Payment Amount: $539.70 Initials: WER Payment Date: 01/25/2013 09:03 AM User ID: 1655 Balance: $0.00 Payee: AMPLE ELECTRIC GROUP INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1536 539.70 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 539.70 Total: $539.70 rinr. RPraint -f1R PrintAri• f11 -2 -2f11� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL12 -1141 Address: 1026 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 12/06/2012 Applicant: CHILDREN'S PLACE Issue Date: Receipt No.: R12 -03270 Payment Amount: $134.93 Initials: WER Payment Date: 12/06/2012 01:41 PM User ID: 1655 Balance: $539.70 Payee: ARCVISION INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 27421 134.93 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 134.93 Total: $134.93 rinr. RPraint -(1R Printari• 17 -(1R -9!117 INSPECTION RECORD Retain a copy with permit INSPE TION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 •(206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 b'" Project: (I , Type of Inspection: . :', Address: /024 � k 1 Date Called: Special Instructions: Date Wanted:. o . . Requester: Phone No: : ® Approved per applicable codes. COMMENTS: Pt El Corrections required prior to approval r-fiJ Inspector: /, f^' Date::. n REINSPECTION FEE REQUIRED. Prior to next inspection;' fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to, schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 fu7/11q1 (206) 431 -3670 Project: Col �k 5 I Type of Inspection: 2100 /J��►� Address: J j�,1,� Date Called: Special Instructions: Date Wanted:. 3/(4° P m. Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: T"3 6140c4-1345 rme r D.K ,Sf oc4/5`Pbw Inspector: Date: 036/ 3 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila.. WA 98188 ;lit (2 31 -3670 MIT NO. Permit Inspection Reques Line (206) 431 -2451 Project: 0 ` otoc- p Type of Inspection: - f ur1,A & 4f E litAt-c-E551,43GE Address: /0 d' " - Date Called: lit 551 ta)C 6.0%/C- £ I 8c s ec,( 11.,t_ 6 CJ D Special Instructions: Date Wanted:. 4/05— a. .. p.m. Requester: Phone No: Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: NO r /�"� kE :( j�5 /14)E'. "` �t .— 641/t5 �' A c? G L(A/ gf ok tk(t5 tk 1 vpm r k 6j1- tai - f ur1,A & 4f E litAt-c-E551,43GE sjVO,1 -%- fTo 5- a7.to'dw comp C tutr4ci o (Ai .co flo7' lit 551 ta)C 6.0%/C- £ I 8c s ec,( 11.,t_ 6 CJ D - lAAvarl_D /41. Flti f Inspector:. V I Date: 04/0s /3 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 tz, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 (01-1 ig( Project: l pike,c, Type of Inspection: 003 Address: ( Date Called: Special Instructions: (t 1.00 A • ek - Date Wanted:. 3 - p.m. Requester: P I/ Phone No: J -'i - ter Utd C'i Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6ItcJS gii(rAn 4s n kikati6P P I/ / J -'i - ter Utd C'i - L 4+: M° tA% th4Pa s'n Inspector: Date: o3�0571 ? REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPEfTION NO. CITY OF TUKWILA BUILDING DIVISION (206) 431 -3670 INSPECTION RECORD Retain a copy with permit gd.- IN PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project: /� _ 0 �/ �s KType <� �` of Inspection79d/2fQO Date Called: Address: /o„ i PP A14/ 1 Special Instructions: - tds ok Ll D i 0\ "1 g. %` 6* cli Ac-roe Date Wanted:. 3/04/ NR- a.m Requester: ,(4L-TI Ike e, &o - Cif &16 4E1.1 1,14w'i`1Lf of » »r Phone No: —A . i ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: — tW rJt' k.O - SC vS lid e ;t1.4 ,WJ pA(Gti. 4-d b (/7( .r C r 1,1(1 6 J Loin 6/1'16' 4 k5 - ) mar 1-6 rbt_6 4-T Ui 1 , we - ( - tds ok Ll D i 0\ "1 g. %` 6* cli Ac-roe r y / fAI r64 U4 ! 5C4 W/ l a 6UT L1 (IT i Rooll P.107 uk&Ktniti - ge-ROA 04-AJb i is N kiI ,(4L-TI Ike e, &o - Cif &16 4E1.1 1,14w'i`1Lf of » »r LocAt - L--(c, tfrf4 , Grkc/iT —A . i Inspector: �j/ NAMI Date: 0 / if C REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ,� (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 ita- IN Project: j /,lc.E Type of Inspection: , Address: /024 Date Called: Special Instructions: 4 jOO Date Wanted:. z z/ 6-m. m• Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. G COMMENTS: t gtAw Inspector: Date: O 15 n REINSPECTION'FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD - Retain a copy with permit INSPECTION NO. 6A2-1111 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 lg. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proje •p: r 5 Type of Inspection: too) Address: ��V 24 l Lr�1� : i ,.�j(/ Date Called: Special Instructions: Date Wanted:. 2 o y �p c„,,,,? p.m. Requester: Phone No Approved per applicable codes. Corrections required prior to approval. COMMENTS: #`. 41-A0 oc\io r Inspector: ,1 Date: 02 0(P ! 3 REINSPECTION FEE REQUIRED Prior to next inspection. fee must be paid at 6300 Soutlicenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 'INSPECTION NO >::. PERMIT NO. CITY OF TU.KWILA BUILDING DIVISION 6300- Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit:Inspection.Request Line (206) 431 -2451 641111 1 Project :}f! Address` riAVLV Special Instructions:: Type of Inspection: Date Called: Date Wanted: Requester: 7ooffj,o3 r a.m. p.m. Phone No: Approved' per applicable codes. COMMENTS: LJCorrections required prior to approval. W,A +J KAP 7o, 1, Inspector: j Date: o1III it .,f t l / REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Project Summary PRJ -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address Date 10/25/2012 633 Southcenter Mall For Building Department Use Tukwila, WA 98188 Applicant Name: The Children's Place Applicant Address: Applicant Phone: t• r ELT Ili REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 14 2012 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 6 2012 PERMIT CENTER G Prescriptive C Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist(over). Indicate Prescriptive & LPA spaces cle 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Project Info Project Address Date LTG -INT Revised December 2010 10/25/2012 633 Southcenter Mall Tukwila, WA 98188 Applicant Name: The Children's Place Applicant Address: Applicant Phone: For Building Department Use Project Description New Building Addition 0 Alteration fl Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option Alteration Exceptions (check appropriate box - sec. 1132.3) _] No changes are being made to the lighting and space use not changed J Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan/room #) Occupancy Description Allowed Was per ft2** Gross Interior Area in ft2 Allowed x Area 100 RETAIL 1.33 2833 3768 100 RETAIL FOOTNOTE 10 1.40 2833 3966 102 THRU 106 RETAIL 1.33 565 751 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 8486 Proposed Lighting Wattage Location (floor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 100 CP1 - SURFACE ROUND DOME, 5- F32UT8, EH 17 130 2210 100 DC3 - 6• RECESSED DOWNLIGHT, 25N CMH 3 25 75 100,103,104,106 2328 - EMERGENCY BATTERY UNIT 11 15 165 103 EX. - RECESSED DOWNLIGHT, 100W INC 1 100 100 102,106 RF2 - 2X2 RECESSED TROFFER, 2- P32DT8, BB 5 55 275 104,105 SF1 - 4' -2LAMP FLUORESCENT STRIP, 2-F32T8, EB 7 46 322 100 SF4 - 4' -1 LADE FLUORESCENT STRIP, 1- P32T8, RE 48 30 1440 100 YA -2 - SURFACE TRACK LIGHTING, 25W Cr4E 63 25 1575 100,104,106 X3 - LED EXIT SIGN 2 3 6 100 X11B - LED EXIT SIGN 1 3 3 Total Prnnnend tAl,Hc ,.,� t y no v,,..ccd Total Allowed Watts for Interior otal Proposed Watts 6171 Notes: 1. For proposed Fixture Description, indicate fixture type, Tamp type (e.g. T -8), number of tamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (In feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/ Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the Tamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary (back) LTG -INT ianoe Forms for Nonresidential and Multifamily Residential Revised December 2010 Prescriptive Spaces Occupancy: 0 Warehouse or Parking Garage ® Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked. the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified. do LPA Calculations. Lighting Fixtures: (Section 1521) ] Check if 95% or more of fixtures comply with 1.2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T-5, T -8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. -1 Unit Lighting Power Allowance (LPA Use' LPA (W/ft `) Use' LPA`(W /ft`) 0.91 Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments', restaurants/bars5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail1p retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified laboratory shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only` Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15-1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Ught Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w/ft2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter - height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories 1, il, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be tumed off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height. is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the ranks The heinht allnwanre defined in fnntnnte 2 annlies nnhr to the flnor area not rnvererl by rar•.kn 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential ig mg, ► o or, an • rans ormer Permit Plans Checklist LTG -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address ]Date 10/25/2012 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2009 Washington State Nonresidential Energy Code. Applicability (yes, no n.a.) I Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) Yes 1513.1 Local control/access Schedule with type. indicate locations 21.0 Yes 1513.2 Area controls Maximum limit per switch E1.0 N.A. 1513.3 Daylight zone control Schedule with type and features, indicate locations N.A. vertical glazing Indicate vertical glazing on plans N.A. overhead glazing Indicate overhead glazing on plans Yes 1513.4 Display /exhib /special Indicate separate controls 21.0 N.A. 1513.5 Exterior shut -off Schedule with type and features, indicate location N.A. (a) timerw /backup Indicate location N.A. (b) photocell. Indicate location Yes 1513.6 Inter. auto shut -off Indicate location Yes 1513.6.1 (a) occup. sensors Schedule with type and locations E1.0 Yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability). Indicate size of zone on plans 21.0 N.A. 1513.7 Hotel/motel controls Indicate location of room master controls N.A. 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) Yes ' 1514 Max. watts 'Indicate watts for each exit sign LIGHTING POWER ALLOWANCE (Section 1530 -1532) El. 0 Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture 21.0 N.A. anATAr� ic.__ae__ 1532 irAIII♦ Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture N.A. ' 1511 Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency' TRANSFORMERS (Section 1540) N.A. 1 1540 'Transformers 'Indicate size and efficiency If "no" is circled for any question, provide explanation: • • PER: 4':,.n c 'Y irfr PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -1141 DATE: 12 -06 -12 PROJECT NAME: CHILDREN'S PLACE SITE ADDRESS: 1026 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -11 -12 Complete Incomplete ❑ Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01 -08 -13 Approved ❑ Approved with Conditions Ni Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • Electrical Contractor A business licensed by LEH to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company AMPLE ELECTRIC GROUP INC 2063591249 18261 73Rd Ave Ne Apt A303 Kenmore WA 98028 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602962673 Active AMPLEEG889BL Electrical Contractor 1/12/2012 1/12/2014 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AMPLEEG913RWAMPLE ELECTRIC GROUP INC Electrical Contractor Residential Unused 12/16/2009 12/16/2013 Re- Licensed Electrical Administrator INFORMATION License RAZUMV'882BK Name RAZUMOVICH, VLADISLAV Status Active Business Owner Information Name Role Effective Date Expiration Date RAZUMOVICH, VLAD Agent 01/12/2012 Bond Amount Received Date BOYARCHUK, ROMAN President 01/12/2012 05/22/2012 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Navigators Ins Co 46- BCO27117 05/22/2012 Until Cancelled $4,000.0005/24/2012 1 Lexon Ins Co 9806116 05/19/2011 Until Cancelled 07/06/2012 $4,000.0005/24/2011 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information No records found for the previous 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 01/25/2013 RESPONSIBILITY SCHEDULE Landlord Tenant GC TCP Vendor iPRE. CONSTRUCTION Remarks Permits and Fees (City 1 Mall) x Barricade - X X WHERE REQUIRED IN MALLS. Barricade Graphics x Trash Removal 1 Dumpsters x Landlord Tenant GC TCP Vendor GENERAL CONSTRUCTION Remarks Demolition X X Demising Walls - Studs x NA NA Demising Walls - Gyp Board & Finishing X NA NA Interior Walls - Studs X X Interior Walls - Gyp Board & Finishing X X Sales /Common Area ACT Gelling & Grid X X X Sales Area Hard Ceding - Framing X X X Sales Area Hard Gelling - Gyp Board & Finishing X X X Mirrors X X COLUMNS TO BE MIRRORED PER PLAN Dorn and Frames X X X Door Hardware X X Painting x x Floor preparation x x Floor protection X X Vinyl Base X X Sales Area Flooring X X Sbc k Room Flooring x x Carpet/Walk Off Mat (exterior only) NA NA Landlord Tenant GC TCP Vendor MECHANICAL Remarks HVAC Units X Roof Work X HVAC Unit Curb X HVAC ()Motion (Ductwork, diffusers, etc) X X x Air Balancing x x Exhaust Fan and Venting x X x Fire System (Home, Strobes, Heads) x X Smoke Evacuation System NA IF REQUIRED BY CODE Rre Sprinkler Shut Off x NA NA IF REQUIRED BY CODE SprinlderSystem Modifications X x MODIFY AS REQUIRED Trenching / Coring Existing Slab (Plumbing) X X Plumbing Endures x x x Lan lord Tenant GC TCP Vendor ELECTRICAL Remarks Electrical Service X Meter Sockets X Electrical Panels X X RELOCATE AS REQ'D Transformers X Main Sign Whip x Wiring, Circuiting, Receptacle, switches, etc X x Trenching 1 Coring Existing Slab (Electrical) X X Electrical Control Systems (EMS) X SITE CONTROLS SYSTEM Emergency Lighting / Erat Lighting X X Light F ims X X Lamps X X Cash Wrap wiring x x Fire Alarm Systems X x Telcom / Data wiring x x Conduit X X POS / Telephone system x X Sensamatic Alarm System x X ELECTRIC PROVIDED BY ELECTRICIAN CONTACT Sound System X x Landlord Tenant GC TCP Vendor FIXTURE/FURNISHINGS Remarks Wall Standards / Wall Panel System X X Millwork LI t Cove x x Ann ms x x Cashwrap / Badkwrap X X RoorFnrturePlacement/Assembly x x Fitting Room Accessories / Bench x x Toilet Room Accessories X X INCLUDE HANDDRYER, CHANGING TABLE, ETC. BOH Shelving System q x X BOH Standards and Miscellaneous X X INCLUDE MGR DESK, ALL OTHER SHELVING Landlord Tenant GC TCP Vendor STOREFRONT Remarks Store Front Signage x x Other Signage x . X Neutral Piers & Landlord Bulkhead X X X GC TO BRING TO NEW CONDITION PER PLAN Store Front System X x x GC TO BRING TO NEW CONDITION PER PLAN Store Front Glass X X X GC TO BRING TO NEW CONDITION PER PLAN Store front Doors / Hardware X X X GC TO BRING TO NEW CONDITION PER PLAN Landlord Tenant GC TCP Vendor POST CONSTRUCTION 1 Remarks Fire Extinguishers v x Anal Clean Up/Ready for Occupancy x Post Construction Dumpsters x TCO /CO x Certified As NUEIP/FP Built Submittals k X Warranty Information form submitted to TCP X MUST BE COMPLETED BY GC AT PUNCH All Warranty books n Paper work complete x Operation Manuals X r LIST OF DRA'II NGS DRAWINGS I55UED Y, j.A wow, ovemoo JosiaL 40. . "VogiOgp DRAWING NAME PROJECT OR ENTATI ON TITLE SHEET - KEY PLANS GENERAL INFORMATION GENERAL NOTES GENERAL PRODUCT SPECIFICATIONS ARCHITECTURAL MOLITION PLAN ME I-4ANIGAL DEMOLITION PLAN CONS$RUCTION PLAN PARTITIt TYPES AND DETAILS SCHEDULEAAND DETAILS FIXTURE FLA%FIXTURE SGHEDI E FIXTURE DETAIL PROJECT D I REGTORY NOT USED REFLECTED CEILINGFL'N, NOTES, DETAILS SEISMIC CEILING WPPORA,DETAILS STOREFRONT PLAN AND ELIWATION STOREFRONTASEGTIONS AND IMTAI LS NOT USED PROJECT TENANT ARCHITECT TENANT WORD I NATOR THE CHILDREN'S PLACE STORE #I522 SPACE 155 NESTFIELD 50UTHCENTER MALL 2500 SOUTCENTER MALL TUKWILA, WA, 15155 TERESA BALDUINI CONSTRUCTION PROJECT ADMINISTRATOR THE CHILDREN'S PLACE 500 PLAZA ROAD SECAUCUS, NJ 07014 PHONE (201) 453 -1712 FAX (201) 555 -2552 tbaldulnI @chTldrensp lace .com ARC. VISION 1150 CRAIG ROAD, SUITE 300 5T. LOUIS, MO 65146 LANIE JOHNSON PROJECT COORDINATOR PHONE (314) 4I5 -2400 FAX (3I4) 415 -2300 IIohnson @arcv.com WAYNE JOHNSON 2500 SOUTHCENTER SEATTLE, WA, 18118 PHONE (206) 714 -3455 REVIEWED FOR N COMPLIANCE - NEC DEC 14 2012 City of iia BUILDING VISION 8U I LD I NG DEPARTMENT CITY OF TUKWILA - DEPT. OF COMMUNITY DEVELOPMENT 6500 SOUTHGENTER BLVD. TUKWILA, WA, 55165 1200R>�GHEDULE AND DETAILS TOILET ROOM AND FITTING ROOM DETAI EGHAN I GAL MECHANICAL SPECIFICATIONS MALL LOCATION KR=Y FLAN GODS INFORMATION APPL I GABLE CODES: BUILDING: 2001 IBC. (STATE BLDG. CODE, WAG CHAP. 51 -50) ELECTRICAL: 2006 NEC (LAWS, RULES 4 REG. FOR INSTALLING ELECTRICAL WIRES $ EQUIP. MAC) 216 -46b ENERGY: 2001 WASHINGTON STATE ENERGY CODE (STATE BLDG. CODE, WAG CHAP. 51 -11) FIRE: 2001 1 F (STATE BLDG. CODE, WAG CHAP. 51 -54) MECHANICAL: 200q IMC (STATE BLDG. CODE, WAG CHAP. 51 -52) PLUMBING: 2001 UPC, (STATE BLDG CODE, WAG CHAP. 51 -56 * 51 -57) ACCESSIBILITY: ADAAG (STATE BLDG. CODE, WAC CHAP. 51 -40) OCCUPANCY: USE GROUPS: M - MERCANTILE MECHANICAL PLAN MECHANICAL DETAILS AND SCHEDULES ELEGTRI GAL CONSTRUCTION TYPE: 25 UNPROTECTED (FULLY SPRINKLERED) ELECTRICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS (CONTINUED) ELECTRICAL POWER AND SYSTEMS PLAN ELECTRICAL LIGHTING PLAN ELECTRICAL SCHEDULES AND DETAILS ELECTRICAL DETAILS EGRESS: OCCUPANT LOAD: SALES: 2,555 S.F. / 50 S.F. PER PERSON STOCK: 565 S.F. / 500 S.F. PER PERSON TOTAL OCCUPANT LOAD CODE REQUIREMENTS MAXIMUM TRAVEL DISTANCE TO EXIT MAXIMUM DEAD END CORRIDOR LENGTH MINIMUM CORRIDOR / AISLE WIDTH MINIMUM CLEAR OPENING OF EXIT DOORS ENERGY MANAGEMENT SYSTEM = 14 PERSONS = 2 PERSONS = 16 PERSONS EMSI.0 -EMS SGHEDULE EN 1.0.00 ENERGY ANALYSIS 250 FT. 15 FT. 44 IN. 56 IN. PLUMBING PI .6-\_1 PLUMBING SPECIFICATIONS TOTAL EGRESS WIDTH REQUIRED: .2" PER PERSON X 16 PERSONS = I1 IN. TOTAL EGRESS WIDTH PROVIDED: 105 IN. OCCUPANT LOAD> 50 PROVIDED 2 EXITS PLUMBING CODE: PLUMBING FIXTURE CALCULATIONS PLUPM4t9G IFIGATIDNS (CONTINUED ENLARGED PLUMBI ANS PECIFICATIONS P2.I 1 PLUMBING PLAN AND SFRI NKL 5PI.0 1 Elie#FPRINKLER SPECIFICATIONS FIRE SPRINKLER PLAN AND SCHEDULES WATER CLOSET LAVATORY MOP SINK DRINKING FOUNTAIN REQ'D: 2 REQ'D: 2 REQ'D: I REQ'D: I PROVIDED: 2 PROVIDED: 2 PROVIDED: 1 PROVIDED: I STORE LOCATION KEY FLAN ARGH I TEGTURAL SYM3OL LEGEND A33REV I AT I O NS DETAIL NUMBER SHEET — ELEVATION COLUMN DESIGNATION LEVEL DATUM NORDSTROM 0 O D t: 1 O NOTE ARROW DIMENSION START/END PARTITION DESIGNATION LEASE LINE A.F.F. CL. /4. P. EQ. EXIST. F.R. GC. GYP. BD. REQ'D. TCP. TYP. V.I.F. W.G. N.I.G. O.G. PLYWD. ABOVE FINISH FLOOR CENTERLINE DRAWING EQUAL EXISTING FIRE RATED GENERAL CONTRACTOR GYPSUM BOARD REQUIRED THE CHILDREN'S PLACE TYPICAL VERIFY IN FIELD WATER CLOSET NOT IN CONTRACT ON CENTER PLYWOOD fitn review approval Is ; r.va ���; W v:cgaltm d Fmk/Nod By 1252013 2 ELDflHI 1 SGOPE OF WORK \ NUMBER DRAWING NUMBER DOOR DESIGNATION SECTION/PLAN DETAIL THE CHILDREN'S PLACE STORE *1522 SPACE 155 WESTFIELD SOUTHGENTER MALL 2500 SOUTCENTER MALL TUKWILA, WA, 15155 APPROXIMATE DISTANCE TO PUBLIC TOILET ROOM : 250 FT ROOMNAME 1 ROOM# X -I CX -I - CEILING FINISH BX -I IJ FX -I ' FLOOR FINISH WALL FINISH W WALL BASE DETAIL ROOMNAME 1 ROOM# - NO CHANGE IN EGRESS OR OCCUPANCY - NO CHANGE IN USE. NO STRUCTURAL WORK. NO EXTERIOR WORK. - SELECTIVE DEMOLITION OF NON LOAD BEARING, NON RATED PARTITION WALLS FIXTURES, FINISHES. - PROVIDE INTERNAL NON LOAD BEARING PARTITION WALLS AND INSTALLATION FIXTURES/FIN15HE5. - MECHANICAL - SEE MECHANICAL DRAWINGS. - PLUMBING - SEE PLUMBING DRAWINGS. - ELECTRICAL - SEE ELECTRICAL DRAWINGS. - RELOCATION OF SPRINKLERS TO MATCH LAYOUT F I N15H PLAN ROOM TAG RCP ROOM TAG AND INTERIOR OF NEw RECEIVED CITY OF TUKWILA DEC 0 6 2012 PERMIT CENTER THE GENERAL CONTRACTOR AND EACH SUB TRADE WILL BE RESPONSIBLE FOR REVIEWING THE ENTIRE SET OF DRAWINGS AND NOTING HI5 WORK AS APPLICABLE. WORK INDICATED OR INFERRED ON THE DRAWINGS AND OR REQUIRED FOR COMPLETE OPERATIONAL CODE COMPLIANT INSTALLATION, WILL BE DEEMED AND I NGLUDED IN SUB - CONTRACTOR'S COSTS. - SEE DRAWINGS FOR FULL SCOPE OF WORK Erb \:°: ' 's� Z *rI".5�` :`'.."ib: :.��\`� ,' :,��'.1=11:` 'C > ®2011 ARCVISION, INC THIS DRAWING, THE DESIGN INDICATED, THE FORMAT AND . ARRANGEMENTS ARE THE PROPERTY OF FREDERICK J. GOGLIA, NGARB, R. ANY USE OR REUSE OF ORIGINAL OR ALTERED DESIGN MATERIALS SY THE CLIENT, AGENTS OF THE CLIENT OR OTHER PARTIES WITHOUT THE REVIEW AND WRITTEN APPROVAL OF THE DESIGN PROFESSIONAL SHALL BE AT THE SOLE RISK OF THE OTHERS. FURTHERMORE THE CLIENT AGREES TO DEFEND, INDEMNIFY AND HOLD THE DESIGN PROFESSIONAL HARMLESS FROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES, EXPENSES AND ATTORNEY'S FEES ARISING OUT OF MODIFICATION OR REUSE OF THESE MATERIALS. THE GENERAL CONTRACTOR AND /OR ALL SUB - CONTRACTORS WORKING FROM THESE PLANS AND SPECIFICATIONS ARE NOT TO SCALE SUCH INFORMATION BUT TO CONTACT THE ARCHITECT OR HI5 REPRESENTATIVE REGARDING MEASUREMENTS, IF SUCH MEASUREMENTS DO NOT APPEAR CORRECT, ADD UP PROPERLY OR SCALE CORRECTLY TO THE INDICATED SIZE. THESE DRAWINGS WERE COMPLETED UNDER THE D I REGT SUPERVISION OF: FREDERICK J. GOGL I A DATE ISSUE DATE ISSUE ARCHITECT ARCHITECT? ..a (314) J. RDI ' t S ST. LOUIS, 415-2400 FAX ( ) 415- .GI"CV. . 3 STORE TYPE 2010 -10 TE:GH 2 — B WB PROJECT CHILDREN'S _ ,. IO�2S�I I - TOP REVIE1A1 #I `i 10/26/11 — LL REV I E IAI # I 2 PROJECT SQUARE FOOTAGE SALES SUPPORT TOTAL 2533 SF 565 S 11/01/12 — FOR PERMIT - - _ __ - 6897 REGISTE' ,..r ARCHiTE 1 , � REDERICK J. G t{ LtA �� STORE 1322 STATE OF WASHI GTON SOUTHGENTER MALL r a . S ` 1 0- SEATTLE IAA 018188 3395 SF �$ to the .s #. r �� of work B� Division. NOTE: E: R @VISIOriS wilt require 8 new p SU l and may include additional a Y tionat plan review fees. SCALE AS NOTED DRAWN BY _ JL F SHEET TITLE TITLE SHEET KEY PLANS - SHEET NUMBER t _! - ` ,4RGYISION PROJECT # 120118 CHECKED BY LLJ (POWER AND SYSTEMS GENERAL AND KEYED NOTES GENERAL POKER AI{0 SYSTEM NOTES A. ANY EX/ST1NG COND /71ONS INDICATED ARE BASED AN INFORMA770N PROVIDED BY OTHERS AND POSSIBLE LIMITED FIELD IOR/F/CA710N. THE CONTRACTOR SHALL ADJUST FOR ACTUAL f7ELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. B. THE CON7RACTOfR SHALL 1ST 771E PROJECT SITE REVIEW EX/ST7NG CONDITIONS AGAINST THE PLANS AND FAMILIARIZE HIMSELF WITH THE WORK PR /OR 70 BIDDING AND START OF THE WM. C: 7IIE CONTRACTOR IS RESPONSIBLE FOR DEMOJ77ON OF EXISTING EQUIPMENT, DEVICES AND LUMINAIRES AS INDICATED AND /OR AS REQUIRED TO ALLOW FOR INSTALLA770N AND CONSTRUCTION OF THE NEW b tWK. RE I1OVE ALL EQUIPMENT; DEVICES LUMINAIRES CONDUITS SUPPCRTSy HANGERS ETC THAT ARE NOT SHOWN AND ARE REQUIRED TV BE REMOVED IN ORDER TD COMPLETE THE NEW WORK. D. RECESSED BOXES AND CONDU /TS CONCEALED WITHIN WALLS OR FLOORS THAT ARE 70 REMAIN ARE PERMITTED 70 BE ABANDONED IN PLACE ONLY IF 77/E OPENINGS ARE PATCHED AND THE CONDUCTORS ARE REMOVED. E. THE OWNER SHALL HAVE F7RST SALVAGE RIGHT ON ALL DEMOLISHED EQUIPMENT, DEVICE'S LUMINAIRES AND MATERIALS THE CONTRACTOR SMALL DISPOSE OF ALL DEMOLISHED EQUIPMENT; DEVICES LUMINAIRES, AND MATERIALS 771E OWNER REJECTS F. MAINTAIN CON77NU/TY OF EX/S77NG C/RCU /T5' AS REQUIRED 7D PROVIDE POWER TO REMAINING EQUIPMENT, DEVICES AND LUMINAIRES THAT ARE NOT BEING REMOVED. G. COORDINATE ALL DEVICE LOCATIONS AND CIRCUIT ROUTING WHIN MILLWORK WITH MILLWORK VENDOR PRIOR 70 ROUGH -IN. H. SLAB C1UTT7NG AND TRENCHING SHALL BE DONE PER LANDLORD STANDARDS. COORDINATE ALL SLAB CUTTING WITH THE CHILDREN'S PLACE FIELD TENANT REPRES'ENTATTVE. REPAIR VAPOR BARR /ER PR /O7 TO POJRBACK DOWEL POURBACK INTO EXISTING SLAB. I. RUN PHONE LINES FOR MAIN AND CORDLESS TELEPHONES TO CASH WRAP OUTLET. J. ELECTR /CAL OU7ZE7S AT THE SALES AREA WALLS MUST EXTEND THROUGH AND BE FLUSH WITH THE FACE WALL K. ALL OUTLETS AND COVER PLATES THROUGHOUT SPACE 7O HAVE NH /7E FINISH. L REFER TO ENERGY MANAGEMENT SYSTEM DRAWING a1S1.0 FOR ADDI11ONAL INFORMATION ON SYSTEM FUNCTIONS AND YVRK REQUIRED. M. SEE PANEL SCHEDULES FOR /NFORMA170N ON CIRCUITS THAT ARE 7V BE ROUTED THROUGH ENERGY MANAGEMENT SYSTEM FOR CONTROL. N. THIS PROECT UTILIZES A PLENUM RETURN A/R CHUNG DESIGN. ALL EQUIPMENT AND MATERIALS INSTALLED WITHIN THE PLENUM RETURN CEILING MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF 25/50 AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS PO AIIV SYSTEMS N07E& 1. PROVIDE JUNCTION BOX WITH ISOLATED GROUND LOCATED ABOVE THE CEHUNG FOR SECURITY SYSTEM. 2. NOT USED. 3 ADT TELEPHONE LINE. OUTLET BOX MOUNTED +90" A.F.F. 4. NOT USED. 5. PROVIDE SERVICE DOOR CALL BUTTON SYSTEM INCLUDING PUSH BUTTONS, TRANSFORMER, BUZZER IN CEILING ADJACENT 70 CASHWRAP, AND BUZZER ABOVE' CE/UNG ADJACENT 7O MANAGER'S DESK. 6. LOCATE BUZZER ABOVE (EILING. 7. PROVIDE ONE 1" SPARE CONDUIT WITH PULL STRING 70 ACCESSIBLE CEHUNG SPACE. 8. POWER PACK "B" ABOVE CEHUNG. SEE DETAIL 4/1-50 FOR ADDITIONAL INFORMATION. 9. RUN CONDUITS DOWN FURRED WALL AS REQUIRED FOR CONDUITS' 70 CASHWRAP. STUB CONDUIT BEHIND KICK BASE AT CASHWRAP. SEE CASHWRAP ELEVATION ON SHEET £50 FOR POWER AND DATA OWLET LOCA770N5 1Q PROVIDE 3/4' CONDUIT FROM EAS SYSTEM DIGITAL CONTROLLER TO DOOR MULLION FOR EAS SYSTEM WIRING (BY SENSORMA77C). PRONDE BUSHING AT CONDUIT TERMINA710N5 SEE' DETAIL 4/£550. 11. SENSORMA77C DOORMAX SECURITY SYSTEM. RtttK TO INSTALLATION GUIDES FOR SYSTEM REQUIREMENTS 12. CONFIRM EXACT LOCA77ON OF EMS BUTTON OVERRIDE ON WING WALL W77H THE CHILDREN'S PLACE REPRESEWTA77VE PR/OR TO ROUGH- /N. MOUNTED +54" A.F.F. 13 SHOPPER7RAK INSTALLED ON FACE OF SOFFIT ABOVE ENTRY BY VENDOR. 14. APPROXIMATE LOCA710N OF AUDIO SYSTEM VENDOR FURNISHED, ELECTRICAL CONTRACTOR INSTALLED MUSIC EQUIPMENT SHELF MOUNTED ON TELECOMMUNICATIONS EQUIPMENT BACKBOARD. SEE DETAIL 6/x'5.0. RECEPTACLE MOUNTED +90" A.F.F. 15 SINGLE GANG WALL BOX MOUNTED BEH /ND SOUND SYSTEM EQUIPMENT. SEE DETAIL 6/£5.0. ',UNCTION BOX MOUNTED +90" A.F.F. 16. RECEPTACLE FOR UNDERSHELF LUMINAIRE. SEE SHEET E3.0 FOR LOCATION OF LUMINAIRE. 1Z PROVIDE A 4=0" x 8=0" x 3/4" UL- LABELED PRE-RETARDANT PLYWOOD BACKBOARD FOR TELECOMMUNICATIONS EQU /PMENT. THE TOP OF 771E BACKBOARD SHALL BE MOUNTED 10=0" A.F.F. PROVIDE GROUND BAR MOUNTED ON BACKBOARD WITH EQUIPMENT GROUNDING CONDUCTOR CONNECTED TO POWER SYSTEM'S GROUNDING ELECTRODE SYSTEM EXTEND EX1S77NG LANDLORD TELECOMMUNICATION CONDUIT TO THIS LOCATION. RECEPTACLE MOUNTED +90" A.F.F. 1a PROVIDE WALL MOUNTED RECEPTACLE FOR ARMOIRE LIGHTING. ALIGN TOP OF RECEPTACLE Mill THE TOP OF THE ARMOIRE. 19. PROVIDE FINAL CONNECTION TO S/GNAGE COORDINATE LOCATION AND ALL REQUIREMENTS WITH S/GN CONTRACTOR PR /OR TO ROUGH -- /N. PROVIDE A LOCAL DISCONNECTING MEANS MOUNTED IN AN ACCESSIBLE INCONSPICUOUS LOCA7TOW. EACH S/GN CIRCUIT SHALL HAVE A SEPARATE NEUTRAL AND SEPARATE EQUIPMENT GROUNDING CONDUCTOR. 20. PROVIDE A 3/4" CONDUIT WTH PULL STRING FROM OWNER FURNISHED PRICE CHECKER LOCA770N 70 LE7/JNG SPACE. 21. DIMENSION 511O$1 IS THE MAXIMUM WALL SPACE AVAILABLE FOR THE INSTALLA770N OF THE ELECTR /CAL EQU /PMENT. 22. ELECTRICAL CONTRACTOR SHALL INSTALL GINNER FURNISHED SPEAKERS VERIFY QUANTITY AND PLACEMENT OF SPEAKERS PRIOR TO ROUGH -IN. THE QUANTITY AND PLACEMENT CAN VARY BY STORE LOCATION. SPEAKERS SHALL BE PAINTED BLACK. 23. PROVIDE TWO 3/4" CONDUITS WITH PULL STRING TO ACCCESSIBLE CE/UNG SPACE FOR CASHWRAP DATA. 24. PROVIDE A 1" CONDUIT WITH PULL STRING 70 ACCESSIBLE C£/UNG SPACE FOR CASHWRAP TELEPHONE 25. HOLD -UP BUTTON INSTALLED BELOW COUNTER? VERIFY LOCA710N W771 THE CHILDREN'S PLACE REPRESENTA77VE PR /OR TO ROUGH -- /N. 26. NOT USED. 2Z RETURN SIDE DUCT SMOKE DETECTOR AND RELAY FOR HVAC UNIT SUPPLY FAN SHUTDOWN SHALL BE FURNISHED BY THE ELECTR /CAL CONTRACTOR FOR INSTALLA770N BY THE MECHANICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL ALSO PROVIDE A REMOTE KEYED TEST STA770N WI771 VISUAL STATUS ANNUNCIATOR WHEN DUCT SMOKE DETECTOR IS INSTALLED IN A CONCEALED LOCATION GREATER THAN 10'-0" ABOVE RN /SHED FLOOR OR WHEN DUCT SMOKE DETECTOR'S STATUS INDICATORS ARE NOT READILY VISIBLE. COORDINATE LOCA770N OF REMOTE KEYED TEST STATION WITH AUTHORITY HAVING alR /SD /C17ON AND OWNER PRIG? TO ROUGH - /N. ALL FINAL WIRING SHALL BE BY THE ELECTRICAL CONTRACTOR. 2Q ROUTE CONDUITS IN 7HE FLOOR. 29. PROVIDE ONE HUBBELL TWO -GANG FLOOR BOX MODEL 0423341 WITH TWO /52625 COVERS FOR CASHWRAP POWER AND ONE HUBBELL TWO -GANG FLOOR BOX MODEL 409423341 M77/ TWO 153425 COVERS FOR CASHWRAP DATA. EXACT FLOOR BOX MODEL NUMBER TO BE DETERMINED BY 171E CHILDREN'S PLACE. ALTERNATE FOR FLOOR BOX WOULD BE TO STUB CONDUITS UP AT LOCA770N INDICATED. EMS DEVICE LEGEND SYMBOL DEVICE 2 DIGITAL ZONE CONTROLLER STORE TYPE 2010 -10 TECH 2 - 53 W$ ENERGY METER ® OVERRIDE BUTTON >. LIGHTING CONTROL PANEL ® OCCUPANCY SENSOR ® POWER INTERFACE PANEL ® SCREAM LOGIC PANEL ® OUTSIDE SENSOR DEVICE NOTE LOW VOLTAGE CABLING SHALL NOT BE MOUNTED TO ANY LAMINATED SURFACE, E.0 CASHWRAP F7N /SHED SURFACES HALLWAY 106 FITTING ROOM 102 GFCI L1 -3 IllariffigkOk r - r-- EXISTING TOILET ROOM SALES AREA (DISPLAY WINDOW NOTE 16 GA V t BOX MOUNTED A71 '' CK NOTE 18 NOTE 18 r-NOTE 18 L1- 7,9,11 NOTE 17 NOTE 3 I NOTE 18 I NOTE 10 NOTE 13 / NOTE 11 NOTE 19 �TTT.'i`/.vin .mvxrcrrcrcrn:m.wm»vrc St PHSJBUTTON NOTE 6 AT SERVICE DOOR lEVAV-2 L J ir NOTE 25 NOTE 28 NOTE 18 NOTE 23 NOTE 24 NOTE' 18 S OCK ROOM DISPLAY WINDOW RECEIVED CITY OF TUKWILA DEC 0 6 2012 PERMIT CENTER L12 114 1 LEGEND EXISTING NEW WORK NEW TO EXISTING CONNECTION 1 ELECTRICAL POWER PLAN SCALE:1 /4' = I' -0' © 2011 ARGYI510N, INC THIS DRAWING, THE DESIGN INDICATED, THE FORMAT AND ARRANGEMENTS ARE THE PROPERTY OF FREDERICK J. GOGL.IA, NGARB SDI. ANY USE OR REUSE OF ORIGINAL OR ALTERED DESIGN MATERIALS BY THE CLIENT, AGENTS OF THE CLIENT OR OTHER PARTIES WITHOUT THE REVIEW AND WRITTEN APPROVAL OF THE DESIGN PROFESSIONAL SHALL BE AT THE SOLE RISK OF THE OTHERS. FURTHERMORE THE CLIENT AGREES TO DEFEND, INDEMNIFY AND HOLD THE DESIGN PROFESSIONAL HARMLESS FROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES, EXPENSES AND ATTORNEY'S FEES ARISING OUT OF MODIFICATION OR REUSE OF THESE MATERIALS. THE GENERAL CONTRACTOR AND /OR ALL SUB - CONTRACTORS WORKING FROM THESE PLANS AND SPECIFICATIONS ARE NOT TO SCALE SUCH INFORMATION BUT TO CONTACT THE ARCHITECT OR HIS REPRESENTATIVE REGARDING MEASUREMENTS, IF SUCH DATE I55UE REV DATE I55UE ARCHITECT ROBERT L. QUEATHEM E NE� 1950 CRAIG ROAD, &RE 300 S7. LOW, III 63146 PH. (314) 415-2400 FAX (314) 415 -2300 .Br#Y.c�om STORE TYPE 2010 -10 TECH 2 - 53 W$ PROJECT , �� ,,eer 50UTHGENTR SEATTLE, CHIL y� a,, � �$d� mow., STORE 1322 MALL WA GIST SS I q. `� F '�' .fit f•� SUB • � �. (.A fj�(/(�� ' � t'I'c �' �. ;' ' 1. °1 � .:- ... �1- 45481 we ,x 1'o RFCrs ac,- } SSfONALE� jm, r` ~ = 4 ti t 10/26/11 - TGi� RE1� I EV�I # I A 10/26/11 $k L.L. REYI �� I A PROJECT SQUARE FOOTAGE SALES SUPPORT TOT, L 2833 SF 565 SF 11/01/12 - FOR PERMIT 33g8 SF SCALE AS NOTED DRAWN BY JM SHEET TIME ELEGTRI GAL POI1 ER AND SYSTEMS PLAN SHEET -- NUMBER _-- o 0 MEASUREMENTS SCALEUP TO THE INDICATECORRECT, IZE D UP PROPERLY OR THESE DRAWINGS WERE COMPLETED UNDER THE DIRECT SUPERVISION OF: FREDERICK J. 606LIA ARCVISION PROJECT # I20ag• CHECKED BY JM 2 I NOT USED AL SCALE:NOT TO SCE AURAL LICKING NOTE& A. ANY EXISTING CONDITIONS INDICATED ARE BASED ON INFORMATION PROVIDED BY OTHERS AND POSS9'BLE UM /TED FIELD VERIFICATION. THE CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD COND /T1ONS AT NO ADDITIONAL EXPENSE 70 THE OWNER. B. THE CONTRACTOR SHALL VISIT 7HE PROJECT SY7E, REVIEW EXISTING CONDITIONS AGAINST THE PLANS AND FAMILIARIZE HIMSELF WITH THE WORK PRIOR TO BIDDING AND START OF THE WORK. C. 77/E CONTRACTOR IS RESPONSIBLE FOR DEMOU77ON OF EXISTING EQUIPMENT, DEVICES, AND LUMINAIRES AS INDICATED AND /OR AS REQUIRED 70 ALLOW FOR INSTALLATION AND CONSTRUCTION OF THE NEW WORK. REMOVE ALL EQUIPMENT; DEVICES, LUMINAIRES CONDUITS SUPPORTS HANGERS, ETC. THAT ARE NOT SHOWN AND ARE REQUIRED TO BE REMOVED IN ORDER 70 COMPLETE THE NEW $ORK. D. RECESSED BOXES AND CONDUITS CONCEALED WITHIN WALLS OR FLOORS THAT ARE 70 REMAIN ARE PERM /TIED TO BE ABANDONED IN PLACE ONLY IF 77-/E OPENINGS ARE PATCHED AND THE CONDUCTORS ARE REMOVED. E. THE OWNER SHALL HAW FIRST SALVAGE RIGHT ON ALL DEMOLISHED EQUIPMENT, DEVICES LUMINAIRES AND MATERIALS THE CONTRACTOR SHALL DISPOSE OF ALL DEMOLISHED EQUIPMENT, DEVICES LUMINAIRES AND MATERIALS THE OWNER REJECTS F. MAINTAIN CONTINUITY OF EX /STING CIRCUITS AS REQUIRED TO PROVIDE POWER TO REMAINING EQUIPMENT, DEVICE AND LUMINAIRES THAT ARE NOT BEING REMOVED. G. ALL OUTLETS AND COVER PLATES THROUGHOUT SPACE TO HAVE WHITE FINISH. H. EMERGENCY LIGHTING LEVELS AT THE FLOOR 70 BE VER/f7ED BY THE INSTALLING CONTRACTOR. PROVIDE ADD /TTONAL F1XTFURES AS REQUIRED BY THE AUTHORITY HAVING JJR /SD /C7TON. /. REFER TO ENERGY MANAGEMENT SYSTEM DRAWING EMS1.0 FOR ADD /TTONAL INFORMATION ON SYSTEM FUNCTIONS AND WgRK REQUIRED. J. SEE PANEL SCHEDULES FOR INFORMATION ON CIRCUITS THAT ARE TV BE ROUTED THROUGH ENERGY MANAGEMENT SYSTEM FOR CONTROL K. THIS PROJECT UTILIZES A PLENUM RETURN AIR CEILING DESIGN. ALL EQUIPMENT AND MATERIALS INSTALLED WITH IN THE PLENUM RETURN CEILING MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF 25/50 AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS LIMING AV7E& 1. EMERGENCY UGH77NG CIRCUIT SHALL BE ROUTED AHEAD OF ANY UGHITNG CONTROLS SO AS 7D OPERATE 24 HOURS A DAY, SEVEN DAYS A WEEK. 2. LUMINAIRE IS INTEGRAL AND RECEIVES POWER FROM THE ARMOIRE. SEE SHEET E2.0 FOR THE LOCA77ON OF THE RECEPTACLE SERVING THE ARMOIRE. 3. S/7E CONTROLS UGH7TNG CONTROL PANEL LOCATION. PANEL 70 INCLUDE OWRRIDE FUNCTION 7V SYSTEM SCHEDULE. REftN 70 SHEETS EMS1.0 FOR ADDITIONAL /NFO?MA77GV. 4. CONNECT UNDERSHELF LUM /NAIRE 70 RECEPTACLE. SEE SHEET E2.0 FOR RECEPTACLE LOCA770N AND CIRCUIT CALLOL/7 EXIT AND EMERGENCY LIGHT F7X7URE TYPES AND LOCATIONS ARE SUBE'CT 70 BUILDING DEPT. AND LANDLORD APPROVAL EMS DEVICE LEGEND SYMBOL DEVICE ® BUTTON OVERRIDE ID LIGHTING CONTROL PANE. ® OCCUPANCY SENSOR ® POWER INTERFACE PANE ® SCREAM LOGIC PANEL SEE ARCHITECTURAL SHEET A4.0 FOR LUM /NAIRE LAYOUT AND QU4TlTY. ALL LUMINAIRES EMS COMPONENTS AND EXIT SIGNS WILL BE fURNISV BY 77/E CHILDREN'S PLACE FOR INSTALLATION BY THE ELECTRICAL C0NIRcrew'i. LIGHTING GENERAL AND KEYED NOTES NOTE 1, (TYPICAL) NOTE 4 L1 -33 HALLWAY °-.-1-- 106 1 FITTING ROOM 102 JANITOR CLOSET , t,,.....uim...7.rmmmim... / x RF -2 Alammirmet Amu mosigimilimiiiiiiiii...mr-imiwuniommi N 7 � ::: b IIIIIi ...! liammir. VI fi r' maim AMP ii„ smed 105 REVIEWED OR WITH COMPLIANCE EB NFPA7 DEC 14 2012 City of Tukwila IpN { BUILDING EXISTING TOILET ROOM 103 ANOTE ANOTE 2 �_ _ �_ _ :, Ammora SF -4 SF -4 SF -4 SF -4 SF -4 YA -2 YA- YA -2 YY -1 YA -2 YA -2 YA -2 0 YY -1 YA -2 EM2B 39 IMP 'ANEL 'L 39 (�] NOTE WM EM2W NOTE 3 4 4 YA -2 YY -1 A- YA -2 YA -2 YY -1 YY -1 YA.. 2 1 -27,29 CF -1 EMS2 4 39 SF -4 2 YA -2 EM2B 1 -1 StOCK ROOM 104 YA -2 YA -2 0 L1-22 YY -1 YA -2 YY-1 F -43 0 YA -2 YA -2 YY-1 YA -2 YA -2YY -1 • YY -1 YA -2 SF -4 CF -1 EMS1 2 0 YA -2 SF -4 SF -4 SF— 4 A -2 YA 2 YA -2 YY -1 YA -2 L1-23 EMS 4 OYA-2 YY -1 A -2 Mair NOTE 2 SF -4 A -2 EM2B 39 1CF-1 EMS2 4 39 YA -2 YA -2yy_1 0 YY -1 EM2B SF —#F SF -4 YA -2 YA -2 YA -2 YY -1 CF-1 EMS1 2 SF -4 Y SF -4 SF-4 SF -4 SF -4 O YA -2 YY-1 YA -2 YA -2 YY -1 SALES AREA 100 ANOTE 2 ire► ..al= w .11 *• .. SF- YA -2 CF- EM S2 4 YY-1 SF -4 SF- NOTE 2 1 a d DISPLAY WINDOW gbh .. . ..T:O 100E 0 SF -4 YA -2 YA -2 YY-1 39 W EM2B 39 O eY YY-1 YA-2 Q EM2B O SF YY-1 SF -4 YA -2 A -2 YY 1- YA -2 NOTE1 (T / ) YA -2 YA -2 YA -2 ILA -2 SF -4 SF— YA 2 YA -2 YY -3 YA -2 L1 -30 -42 —3 C- 1 X11 B 39 L1 -24 YA •2 YY -1 YA -2 SF -4 D YA -2 YA -2 1 YY-3 YA -2 IMF .......... NOTE 2 DISPLAY WINDOW 100F L1-30 RECEIVED CITY OFTUKWILA DEC 0 6 2012 PERMITCENTER 1„1,1 (4 1 LEGEND '5 EXISTING NEW WORK NEW TO EX/S77NG CONNEC77ON ELECTRICAL LIGHTING PLAN SCALE:1 4 = 1--00 © 2011 ARGVISION, INC THIS DRAWING, THE DESIGN INDICATED, THE FORMAT AND ARRANGEMENTS ARE THE PROPERTY OF FREDERICK J. GOGL IA, NCARB, RDI. ANY USE OR REUSE OF ORIGINAL OR ALTERED DESIGN MATERIALS BY THE CLIENT, AGENTS OF THE CLIENT OR OTHER PARTIES WITHOUT THE REVIEW AND WRITTEN APPROVAL OF THE DESIGN PROFESSIONAL SHALL BE AT THE SOLE RISK OF THE OTHERS. FURTHERMORE THE CLIENT AGREES TO DEFEND, INDEMNIFY AND HOLD THE DESIGN PROFESSIONAL HARMLESS FROM ALL CLAIMS, INJURIES, DAMAGES, LOCfCS, EXPENSES AND ATTORNEY'S FEES ARISING OUT OF MODIFICATION OR REUSE OF THESE MATERIALS. THE GENERAL CONTRACTOR AND /OR ALL SUB — CONTRACTORS WORKING FROM THESE PLANS AND SPECIFICATIONS ARE NOT TO SCALE SUCH INFORMATION BUT TO CONTACT THE ARCHITECT OR HIS REPRESENTATIVE REGARDING MEASUREMENTS, IF SUCH MEASUREMENTS DO NOT APPEAR CORRECT, ADD UP PROPERLY OR SCALE CORRECTLY TO THE INDICATED SIZE. THESE DRAWINGS WERE COMPLETED UNDER THE DIRECT SUPERVISION OF: FREDERICK J. 606L IA DATE ISSUE REV DATE ISSUE 10/26/11 TGP REV I EIN #1 IO /26 /II - LL REVIEY1 #I 11/01/12 - FOR PERMIT ARCHITECT ROBERT L. QUEATHEM ENGINEER 1950 CRAIG ROAD, SURE 300 ST. LOUIS, MO 63146 PH. (314) 415 -2400 FAX (314) 415 -2300 www.ercvcom STORE TYPE TECH 2— 5 2010 -10 INB PROJECT SQUARE FOOTAGE SALES SUPPORT TOTAL SCALE AS NOTED 2855 5F 565 5F 5518 5F DRAWN BY JM ARGVISION PROJECT # 120118 CHECKED BY JM PROJECT C4 ICCT TITLE THE cEIij:EJ'q STORE 1522 SOUTHGENTER MALL SEATTLE, INA 1 S I SS ELEGTRI GAL LIGHTING PLAN r.HCET NUMBER 300 LIGHTING FIXTURE SCHEDULE MARK MANUFACTURER PHASE LAMP SPECIFICATION (SEE GENERAL NOTE A) SECONDARY MOUNTING I REMARKS VOLTS CATALOG NUMBER I CEILING I RECESS 1SURFACEI - - 6 JCABLE CATALOG NUMBER LAMP QUAN LAMP DESCRIPTION LAMP TYPE CF -1 UTE CONTROL S- D- 38- L- 5- T8U6- FP- TCWM -ELB10 -277 5 FB032/835/6/ECO SYLVANIA FL 120 351 LBS. X OF X NOTES: ALL TRANSFORMERS ALL TRANSFORMERS ALL TRANSFORMERS ALL TRANSFORMERS SHALL SHALL SHALL SHALL HAVE ALUMINUM WINDINGS UNLESS NOTED OTHERWISE. HAVE CLASS 220 INSULATION SYSTEM UNLESS NOTED OTHERWISE. HAVE VENTILATED ENCLOSURES UNLESS NOTED OTHERWISE. BE NEMA TP -1 RATED. CEILING SURFACE DECORATIVE ROUND DOME UGHT. DC -3 CON -TECH LIGHTING RL38- CTR1902 -CLR 1 CDM -1 25/PAR38/ FL /3K (BY PHILIPS) MH 120 WALL MOUNTED RANGE RECEPTACLE, NEMA 14-50R UNLESS INDICATED OTHERWISE X X 1080 WALL MOUNTED TELEPHONE OUTLET 125% 200 6" RECESSED DOWNUGHT RF -2 UGHTOUER DP- A- 2- G- 9- W- S- 2- 6U- UNIV -SO 2 FB032/835/6/ECO SYLVANIA FL 120 OF X X WALL MOUNTED COMBINATION TELEPHONE/DATA OUTLET Uj CEIUNG MOUNTED JUNCTION /OUTLET BOX -© 2X2 RECESSED DEEPCELL TROFFER. SF -1 SIMKAR IE- 232- A- B11 -UNV 2 F032T8/835 FL 120 CEIUNG MOUNTED COMPUTER OUTLET X EXPOSED BRANCH CIRCUITING X X 100% P55411"2* 4' STOCK ROOM INDUSTRIAL STRIP UGHT. SF -4 SIMKAR CH- 1- 32- B11HPH -UNIV 1 F032T8/835 FL 120 MOTOR X CONDUIT DOWN X DISCONNECT (SAFETY) SWITCH. SEE PLAN FOR RATING. 0 MULTI- OUTLET ASSEMBLY 4' NDAMOUNTING�HARDWARE PROVIDE CONNECTOR:, UNDERCABINET TASK UGHT. TF -1 FSC UGHTING FSC 3148 -132 1 F032T8/835 FL 120 4200 AUTOMATIC HEAT DETECTOR © X $ AUTOMATIC SMOKE DETECTOR F H YA -2 CON -TECH UGHTING CTL603 -P -MOD 1 FL% K (BY PHIL / S) MH 120 Di X © ♦ X 88 APPLIANCE COMBINATION AUDIBLE/VISUAL E/VISUAL NOTIFICATION F �� TRACK MOUNTED SALES ACCENT LIGHT. YY-1 CON -TECH LIGHTING LT SERIES: LT28: 2FL LT45: 4FT, LT6B: 6FT LTBB: BET. LT12B: 12FT _ BLAQ< FINISH - 120 D X D/W RECEPT. X p CEIUNG MOUNTED SPEAKER Imo- SURFACE TO GRID CEIUNG TRACK. VERIFY EXACT TRACK LENGTHS REQUIRED ON P S. YY-3 CON -TECH LIGHTING LT SERIES: LT2P: VT, LT4P: 4FT, LT6P: 6FT LTSP: 8FT. LT12P: 12FT _ WHITE FINISH - 120 MAGNETIC STARTER X RR X DOUBLE RELAY 433 SEE PLAN ENORM GNE11C STARTER AND DISCONNECT SWITCH. SURFACE TO GRID CEIUNG TRACK. VERIFY EXACT TRACK LENGTHS REQUIRED ON PLANS. X11B ROYAL PACIFIC SINGLE FACE: RXL11 -RB - INCLUDED LED 120 IDD X X THREE- BUTTON PUSHBUTTON STATION RI ELECTRONIC SOLENOID VALVE SALES AREA LED EDGE -UT SINGLE FACE EXIT SIGN WITH BLACK CANOPY. X3 EXITRONIX VEX- U- BP -WB -WH - INCLUDED LED 120 X X NON -FUSED X GROUND -FAULT CIRCUIT INTERRUPTER AFT ABOVE FINISHED FLOOR BACK OF HOUSE WHITE THERMOPLASTIC EXIT SIGN. EM2B EXITRONIX LSO -BL EM BUG EYES 2 INCLUDED IND 120 TR X HACR X HG HOSPITAL GRADE NL BLACK DUAL HEAD SALES EMERGENCY LIGHTING UNIT. EM2W EXITRONIX LL90 EM BUG EYES 2 INCLUDED IND 120 EMS -1 X SALES AREA LTG. X 1300 // - WHITE DUAL HEAD SALES EMERGENCY LIGHTING UNIT. LIGHTING FIXTURE SCHEDULE GENERAL NOTES: NOTE A: FL= FLUORESCENT, CFL= COMPACT FLUORESCENT, IND = INCANDESCENT, MH =METAL HALIDE, HPS =HIGH PRESSURE SODIUM, LED =LIGHT EMITTING DIODE IREFER TO 77.0 FOR EXACT PROJECT SCOPE AND RESPONSIBILITY SCHEDULE. (LIGHT FIXTURE SCHEDULE EXISTING DRY TYPE TRANSFORMER SCHEDULE SYMBOL MARK PHASE PRIMARY SECONDARY RATING k11 K FACTOR MANUFACTURER CATALOG NUMBER WIDTH DEPTH HEIGHT WEIGHT WEATHERSHIELD MOUNTING DETAIL T -1 3 PHASE 480V DELTA 120 /208V WYE 45 KVA NONE EATON V48M28T45EE 23" 17" 30" 351 LBS. NO OF GENERAL A. B. C. D. NOTES: ALL TRANSFORMERS ALL TRANSFORMERS ALL TRANSFORMERS ALL TRANSFORMERS SHALL SHALL SHALL SHALL HAVE ALUMINUM WINDINGS UNLESS NOTED OTHERWISE. HAVE CLASS 220 INSULATION SYSTEM UNLESS NOTED OTHERWISE. HAVE VENTILATED ENCLOSURES UNLESS NOTED OTHERWISE. BE NEMA TP -1 RATED. DRY TYPE TRANSFORMER SCHEDULE ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION -e WALL MOUNTED SINGLE RECEPTACLE ELECTRIC METER DEMAND WALL MOUNTED DUPLEX RECEPTACLE '// A SWITCHBOARD OR DISTRIBUTION PANELBOARD DEMAND CONNECT. 30 WALL MOUNTED QUADRUPLEX RECEPTACLE 125% UGHTING AND APPLIANCE PANELBOARD 1575 3237 4046 WALL MOUNTED DEDICATED DUPLEX RECEPTACLE MOD SWITCH. SPST UNLESS INDICATED WITH MODIFIER. HORSEPOWER RATED WHEN USED FOR MOTOR CONTROL OR DISCONNECTING MEANS. (INCLUDING CONBINATIONS THEREOF)( 7015 WALL MOUNTED DUPLEX RECEPTACLE, ONE RECEPTACLE SWITCHED 100% pagilsrDIFIERS 3: 3 -WAY (SPDT). 4: 4 -WAY. D: DIMMER. F• BOX COVER UNIT BUSSMANN SSU OR STY SERIES. G: ?gawks VANDLES GLOWS WHEN SWITCH IS OFF). H: HORIZONTALLY MOUNTED. K: KEY OPERATED. M• OCCUPANCY ENSOR. P: PILOT LIGHT (PILOT ON WHEN SWITCH IS ON). T: TIMER. V: VACANACY SENSOR. LV: LOW VOLTAGE. OR: OVERRIDE. OT: OVERRIDE WITH TIMER. DM: SPDT CENTER OFF MAINTAINED CONTACT. DTM: SPDT, CENTER OFF' MOMENTARY CONTACT. LOWERCASE LETTER: CONTROL LUMINAIRE WITH SAME LETTER. OF FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE F FLUSH FLOOR MOUNTED DEDICATED DUPLEX RECEPTACLE 4860 C._, `.� 10000 FLUSH FLOOR MOUNTED QUADRUPLEX RECEPTACLE 4 CEIUNG MOUNTED DUPLEX RECEPTACLE 0 WALL MOUNTED SPECIAL RECEPTACLE, NEMA CONFIGURATION AS NOTED as WALL MOUNTED RANGE RECEPTACLE, NEMA 14-50R UNLESS INDICATED OTHERWISE 0 AS L MO NTED SPECIAL RECEPTACLE, NEMA CONFIGURATION 1080 WALL MOUNTED TELEPHONE OUTLET 125% 200 0 PEDESTAL MOUNTED RECEPTACLE, SEE PLAN FOR TYPE 625 FLUSH FLOOR MOUNTED TELEPHONE OUTLET -Oj WALL MOUNTED JUNCTION /OUTLET BOX 0 CEIUNG MOUNTED TELEPHONE OUTLET OF FLUSH FLOOR MOUNTED JUNCTION /OUTLET BOX C WALL MOUNTED COMBINATION TELEPHONE/DATA OUTLET Uj CEIUNG MOUNTED JUNCTION /OUTLET BOX -© WALL MOUNTED COMPUTER OUTLET „,,..---- -..„. BRANCH CIRCUITING CONCEALED IN WALLS OR CEILING OF FLUSH FLOOR MOUNTED COMPUTER OUTLET — •■ BRANCH CIRCUITING CONCEALED IN FLOOR © CEIUNG MOUNTED COMPUTER OUTLET 0 EXPOSED BRANCH CIRCUITING -112 WALL MOUNTED TELEVISION OUTLET 100% P55411"2* HOMERUN TO PANEL THE NUMBER OF ARROWS INDICATES THE NUMBER OF CIRCUITS. TWO WIRES UNLESS NOTED OTHERWISE. GROUND WIRE IS REQUIRED BUT NOT COUNTED IN HASH MARKS. W CEIUNG MOUNTED TELEVISION OUTLET 200 TELECOMMUNICATIONS SYSTEM BACKBOARD ,...---Thle CONDUIT UP 0 MOTOR ..„..----..... CONDUIT DOWN LEI DISCONNECT (SAFETY) SWITCH. SEE PLAN FOR RATING. 0 MULTI- OUTLET ASSEMBLY ..../.. J CORD AND PLUG ® POWER POLE @, DROP -CORD FA FIRE ALARM PANEL (CONTROL OR ANNUNCIATOR) 4200 AUTOMATIC HEAT DETECTOR © FIRE ALARM MANUAL PULL STATION $ AUTOMATIC SMOKE DETECTOR F H FIRE ALARM MAGNETIC DOOR HOLD OPEN D DUCT SMOKE DETECTOR 12121 FIRE ALARM VISUAL NOTIFICATION APPLIANCE © 0 FIRE SPRINKLER ALARM BELL Di FIRE ALARM AUDIBLE NOTIFICATION APPLIANCE © ♦ FIRE SPRINKLER FLOW SWITCH 88 APPLIANCE COMBINATION AUDIBLE/VISUAL E/VISUAL NOTIFICATION F �� SYST1a�il RINIP SAMY R SWI TTION D CORROSION MONITORING F© Ey SIGNAUNG SYSTEM BUZZER ED SIGNAUNG SYSTEM BELL a SIGNALING SYSTEM CHIME D SIGNAUNG SYSTEM PUSHBUTTON D/W RECEPT. SOUND SYSTEM AMPLIFIER p CEIUNG MOUNTED SPEAKER Imo- CASHWRAP IG RECEPT. -0 WALL MOUNTED SPEAKER —I WALL MOL ANTED VOLUME CONTROL R RELAY ►rj MAGNETIC STARTER D/W RECEPT. RR EMS -3 DOUBLE RELAY 433 SEE PLAN ENORM GNE11C STARTER AND DISCONNECT SWITCH. D SINGLE BUTTON PUSHBUTTON STATION p CONTROL TRANSFORMER 20/1 TWO- BUTTON PUSHBUTTON STATION TR CONTROL TRANSFORMER IDD 20 EMS -1 THREE- BUTTON PUSHBUTTON STATION RI ELECTRONIC SOLENOID VALVE = A ELECTRICAL ABBREVIATIONS SYMBOL DESCRIPTION SYMBOL DESCRIPTION WP WEATHERPROOF NF NON -FUSED (l GROUND -FAULT CIRCUIT INTERRUPTER AFT ABOVE FINISHED FLOOR GFCI GROUND -FAULT CIRCUIT INTERRUPTER UNO UNLESS NOTED OTHERWISE IG ISOLATED GROUND ST SHUNT -TRIP TR TAMPER- RESISTANT HACR HRACR(HEATING, AIR CONDITIONING AND REFRIGERATION) HG HOSPITAL GRADE NL NIGHTUGHT GFPE GROUND -FAULT PROTECTION OF EQUIPMENT EM EMERGENCY N.E.C. LOAD ANALYSIS FOR PANEL "A" (INCLUDING SUBFEEDS) LOAD DESCRIPTION DEMAND FACTOR PHASE A (VA) PHASE B (VA) PHASE C (VA) TOTAL (VA) CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND LIGHTING: 125% 1260 1575 3237 4046 1115 1394 5612 7015 RECEPTACLE (FIRST 10 KVA): 100% 3960 3960 1180 1180 4860 4860 10000 10000 RECEPTACLE (REMAINDER): 50% 0 0 2160 1080 0 0 2180 1080 OTHER CONTINUOUS: 125% 200 250 500 625 200 250 900 1125 OTHER NONCONTINUOUS: 100% 0 0 0 0 0 0 0 0 WATER HEATER: 125% 1500 1875 1500 1875 0 0 3000 3750 COOUNG ONLY: 100% 0 0 200 200 200 200 400 400 LARGEST MOTOR: 25% 0 167 0 167 0 167 0 501 126' -0" TRACK LTG. AT 150VA/2 FT 25% 3450 4313 1800 2250 4200 5250 9450 11813 TOTAL 10370 12140 10577 11423 10575 12121 31542 35684 EQUIVALENT AMPS: 86 101 88 95 88 101 88 99 PHASE BALANCE: -2% 1% 1% -6% -1% -1% 1800 %l // (NEC LOAD SUMMARY (ELECTRICAL SYMBOL LEGEND LANDLORD DISTRIBUTION POINT TENANT SPACE GENERAL AYE -LINE IZ4G?AM NORM A. ANY £X1S77NG CONDITIONS INDICATED ARE BASED ON INFORMA770N PROVIDED BY OTHERS AND POSSIBLE LIMITED FIELD VERIf7CA77GW. 771E CONTRACTOR SHALL ADJUST FOR AC7UAL f7ELD COND /77ONS AT NO ADD /770NAL EXPENSE 70 771E OWNER. B. 771E CONTRACTOR SHALL VISIT THE PROJECT S'7F REVIEW EX/S77NG COND177ONS AGAINST 771E PLANS AND FAMIUARIZE HIMSELF N1771 7HE WORK PRIOR TO BIDDING AND START OF 771E WORK. C. THE CONTRACTOR IS RESPONSIBLE FOR DEMOU770N OF EXIS77NG EQU IPMENT, DEVICES, AND LUMINAIRES' AS INDICA7ED AND /OR AS REQUIRED 70 ALLOW FOR /NSTALLA770N AND CONSTRUC77ON OF THE NEW KINK. REMOVE ALL EQUIPMENT, DEVICES LUMINAIRES, CONDU /7S SUPPORTS, HANGERS, ETC. THAT ARE NOT SHOW AND ARE REQUIRED TO BE REMOVED IN ORDER 70 COMPLETE 771E NEW WORK. D. RECESSED BOXES AND CONDO /TS CONCEALED WHIN WALLS 01? FLOORS THAT ARE 7O REMA /N ARE PERMIT7ED TO BE ABANDONED IN PLACE ONLY IF 7HE OPENINGS ARE PATCHED AND 771E CONDUCTORS ARE REMOVED. E. THE OWNER SHALL HA V£ f7RST SALVAGE RIGHT ON ALL DEMOLISHED EQU IPMENT, DEVICES, LUMINAIRES AND MATERIALS 771E CON7RACTOR SHALL DISPOSE OF ALL DEMOLISHED EQU IPMENT, DEVICES LUMINAIRES, AND MATERIALS 771E OWNER REACTS F. MAINTAIN CON77NU/TY OF EX/S77NG C/RCU /TS AS REQUIRED 70 PROVIDE POWER 70 REMAINING EQU IPMENT, DEVICES AND LUMINAIRES THAT ARE NOT BEING REMOVED. C SEE DETAIL 8/E5.0 FOR ADD/770NAL /NFORMA770N ON 771E ISOLA 7ED GROUND SYS7E4/. 40' -0" (APPROX.) 1 REFER TO T1.0 FOR EXACT PROIECT SCOPE AND RESPONS7'BIUTY SCHEDULE. LANDLORD SERVICE SERVICE SWITCHBOARD, 800A, 277/480 VOLT, 3 PHASE, 4 WIRE EXISTING G.E.C. — EXISTING 18 G.E.C. �M EXISTING 200/3 XIST1NG TO REMAIN EXISTING METER SOCKET XISTING TO REMAIN —1 EXISTING 200/3 170A FUSES SAFETY J SWITCH f--EXISTING TO REMAIN EXISTING 1 — — TRANSFORMER T -1 45KVA 3 PHASE, 1480 VOLT DELTA PRIMARY, 120/208 !VOLT WYE SECONDARY rEXISTING TO REMAIN 1- J. I 1 PANEL 1 1 "L1" 1 EXISTING L__J LEGEND EXISTING NEW WORK NEW TO EX /S77NG CONNECTION 1 1 I ELENOT CTRTO SCAICAL LE ONE -LINE DIAGRAM SCALE: PANEL "Li" SCHEDULE FED FROM: VOLTAGE: BUS BUS BUS MAIN: 120/208V, 3 PHASE, 4 WIRE MATERIAL: ALUMINUM LOAD: 95.6 AMPS RATING: 225 AMPS 125/3 MAIN BREAKER MOUNTING: SURFACE ENCLOSURE: NEMA FAULT CURRENT: AIC RATING: 10,000 OPTIONS*: W/INSULATED/ISOLATED MOUNTED 1 GROUND BAR LOAD (VA) LOAD (VA) NOTES CKT. LOAD DESCRIPTION A B C BREAKER BREAKER A B C LOAD DESCRIPTION CKT. NOTES EMS -3 1 TRACK LTG. 1800 Vfff� // 20/1 20/1 720 �fff/f SALES RECEPTS. 2 3 EWC RECEPT. % 480 A 20/1 20/1 / 200 /" //4 SENSORMATiC 4 5 SPARE �// �� -- 20/1 20/1 %/ //i 1260 ARMOIRE RECEPTS 6 EMS -3 7 EMPLOYEE DESK REC. 180 1 20/1 20/1 900 �ff MGR'S DESK PLUGMOLD 8 9 EMPLOYEE DESK REC. 180 / 20/1 20/1 / 180 MGR'S DESK LTG REC. 10 EMS -1 11 TELEPHONE BOARD REC. f%/' /� 360 20/1 20/1 �ff 720 MGR'S DESK QUAD REC. 12 HLO HLO 13 ADT SYSTEM RECEPT. 360 �� 20/1 20/1 360 STOCK/HALL RECEPTS. 14 15 SOUND SYSTEM REC. ' 500 4 20/1 20/1 1800 %l // D/W RECEPT. 16 EMS -3 HLO 17 CASHWRAP IG RECEPT. 1/71 720 20/1 20/1 ' / i/ 1800 D/W RECEPT. 18 EMS -3 HLO 19 CASHWRAP RECEPT. 14407/ e 20/1 20/1 -- /r SPARE 20 EMS -1 21 EF -1 % 500 A 20/1 20/1 1800 TRACK LTG. 22 EMS -3 EMS-3 23 TRACK LTG. 1800 20/1 20/1 1500 TRACK LTG. 24 EMS -3 25 SPARE -- //17r 20/1 20/1 1650 I/ �ff� TRACK LTG. 26 EMS -3 EMS -1 27 SALES AREA LTG. % 1300 // 20/1 20/1 // 1200 % / /Ii, EXTERIOR SIGN 28 EMS -4 EMS-2 29 SALES AREA LTG. 77 1040 20/1 20/1 % / / //,ff 900 D/W TRACK LTG. 30 EMS -3 EMS -3 31 SALES VALANCE LTG. 1260 / 20/1 20/1 -- SPARE 32 EMS -1 33 STOCK/RR/HALL LTG. 500 /, 20/1 20/2 200 / EXISTING VAV 34 HLO 35 EMS -1 � 200 20/1 00 � 200 36 37 EMS -2 200 200 �� 20/1 20/2 1500 / /�l HWH -1 38 HLO 39 EMERGENCY/EXITS % 237 20/1 � 1500 40 41 SPARE 20/1 20/1 %/ / /1 /i 75 ENTRY LTG. 42 EMS -3 J•OTES: 1 TOTALS: 5240 3697 4120 5130 6880 6455 SEE SPECIFICATIONS FOR OTHER OPTIONS REQUIRED BUT NOT NECESSARILY NOTED HERE HLO CIRCUIT BREAKER SHALL BE EQUIPPED WITH HANDLE LOCK -ON DEVICE HPL CIRCUIT BREAKER SHALL HAVE HANDLE PADLOCK ATTACHMENT TO LOCK BREAKER IN OPEN POSITION EMS -# CIRCUIT SHALL BE ROUTED THROUGH RELAY CONTROLLED BY ENERGY MANAGEMENT SYSTEM (EMS), # = CONTROL ZONE A PROVIDE NEW CIRCUIT BREAKER TO MATCH EXISTING TYPE AND AIC RATING. REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC DEC 14 2012 City of Tukwila — BUILDING DIVISION NOTE: WHEN REQU /RED BY 771E LOCAL alR /SD /C770N, 771E ENGINEER OR THEIR AGENT WILL BE PERFORMING A SI7E VISIT FOLLOWING 7HE COMPLE770N OF CONS7RUC770N. IT IS 771E CONTRACTOR'S RESPONSIBILITY TO HAVE ALL WORK COMPLETED AT 71IS 77ME 70 ENSURE THAT THERE ARE NO DELAYS IN 771E PROJECT. ANY D£NA7I0NS 70 7HE PLANS MUST BE APPROVED IN WRITING. RECEIVED CITY OF TUKWILA EC 0 6 2012 PEWIT CENTER LEGEND EXIS71NG NEW WORK NEW TO EX/SIMG CONNEC770N Iy (ELECTRICAL PANELBOARD SCHEDULES © 2011 ARGVISION, INC THIS DRAWING, THE DESIGN INDICATED, THE FORMAT AND ARRANGEMENTS ARE THE PROPERTY OF FREDERICK J. GOGLIA, NGARB, RDI . ANY USE OR REUSE OF ORIGINAL OR ALTERED DESIGN MATERIALS BY THE CLIENT, AGENTS OF THE CLIENT OR OTHER PARTIES WITHOUT THE REVIEW AND WRITTEN APPROVAL OF THE DESIGN PROFESSIONAL SHALL 5E AT THE SOLE RISK OF THE OTHERS. FURTHERMORE THE CLIENT AGREES TO DEFEND, INDEMNIFY AND HOLD THE DESIGN PROFESSIONAL HARMLESS FROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES, EXPENSES AND ATTORNEY'S FEES ARISING OUT OF MODIFICATION OR REUSE OF THESE MATERIALS. THE GENERAL CONTRACTOR AND /OR ALL SUB- CONTRACTORS WORKING FROM THESE PLANS AND SPECIFICATIONS ARE NOT TO SCALE SUCH INFORMATION BUT TO CONTACT THE ARCHITECT OR HIS REPRESENTATIVE REGARDING MEASUREMENTS, IF SUCH MEASUREMENTS DO NOT APPEAR CORRECT, ADD UP PROPERLY OR SCALE CORRECTLY TO THE INDICATED SIZE. THESE DRAWINGS WERE COMPLETED UNDER THE DIRECT SUPERVISION OF: FREDERICK J. GOGLIA DATE I55UE IO /26/11 - TCP REVIEN *1 10/26/11 - LL REVIEW #I REV DATE I55UE 11/01/12 - FOR PERMIT ARCHITECT ROBERT L. QUEATHEM ENKANEER 1950 CRAIG ROAD, SATE 300 ST. LOPS, MO 63146 PH, (314) 415 -2400 FAX (314) 415 -2= www.ercv.com STORE TYPE TECH 2 - 13 2010 -10 NB PRO.E CCT SQUARE FOOTAGE SALES SUPPORT TOTAL 2855 5F 565 5F 5518 5F PROJECT THE CH DRENS STORE 1522 SOUTHGENTER MALL SEATTLE, NA x8188 SCALE AS NOTED DRAWN BY KRG ARGVISION PROJECT * I20qCia CHECKED BY JM SHEET TITLE ELECTRICAL SGHEPULES AND r,ETA I LS 51' NUMBER .4.0 ELECTRONIC CASH REGISTER POWER SYSTEM. THE CIRCUITS USED TO POWER THE ELECTRONIC CASH REGISTERS SHALL NOT BE USED FOR ANY 07771E7? PURPOSES. 771E CIRCUITS SHALL NOT SHARE THE NEUTRAL OR GROUND WITH OTHER EQUIPMENT SEPARATE POWER NEUTRAL AND INSULATED GROUND WIRES MINIMUM SIZE /12 AWG SHALL BE RUN TO THE CIRCUIT BREAKER PANEL BOARD WERE GROUND WIRE SHALL BE 77ED 70 THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE THE CYRC1/IT FOR GROUNDING AS THIS IS NOT ADEQUATE AT HIGH FREQUENCIES: THE cIRCU /TS FOR THE ELECTRON /C CASH REGISTERS SHALL BE RUN IN SEPARATE CONDUIT, ELECTRONIC CASH REGISTERS OUTLETS SHALL BE HUBBELL NO 1G5362 OR APPROVED EQUAL THIS SYSTEM IS REQUIRED BY THE TENANT EXTEND 1" EMPTY FLEXIBLE CONDUIT FROM TELEPHONE OUTLET 7O NEAREST CASH REGISTER LOCA770N AND INSTALL 1" EMPTY FLEXIBLE CONDU /T WITHIN CASE $!WK BETWEEN ALL CASH REGISTER LOCATION. DATA CABLES FOR CASH REGISTERS (CATEGORY 5 CABLES) ARE PROVIDED BY THE CHILDREN'S PLACE. ELECTRICAL CONTRACTOR SHALL LEAVE 20 FEET OF FLEX CONDU /T AT THE CASHMi'AP ELECTRICAL OUTLET STUB UP LOCATIONS ELECTRICAL CONDUIT FROM- FLOOR 5168 UP OR COMA, GOIORDINAIE W/ LOCATION IN F'D. SEE STET E20 NOTE COORDINATE RECEPTACLE AND DATA OUTLET LOCATIONS IN FIELD TO ALLOW REQUIRED ACCESS: 1 1 CAE NOT TO SCSHWRALE AP ELEVATION SCAL 1 1" CONDUIT TO ACCESSIBLE CEILING SPACE FOR SHOPPER TRACK 3/4" CONDUIT TO ACCESSIBLE CE/LING FOR PR/CE CHECKER (2 FOR OU7ZE7S) 1" CONDUIT PROM DMARC 1" CONDUIT 70 GANG BOX 2" CONDU /T FROM GANG BOX FOR CCTV JUNC7TON BOX FOR SHOPPER TRACK JUNC77ON BOX FOR BROADBAND/EXTANT UNDERSHELF LUM INA /RE; PROVIDE ALL NECESSARY BLOCKING DIGITAL ZONE CONTROLLER, SEE M20 FOR SITE SPECIHHC PLACEMENT AND QUAN/7TTY JJNCT7ON BOX FOR APPS PC/ DM JACK/ L1,L2 JACK � I MCI JUNCTION BOX FOR INT /CART 5' CC1, CC2, C • a 0 CJ cV 2" CONDU /T 70 ACCESSIBLE CEILING SPACE FOR CCTV WIRING TWO 3/4" CONDUITS' 70 ACCESSIBLE CE/UNG SPACE FOR CASH WRAP DATA GANG BOX MOUNTED ON WALL ABOVE DESK 1 1/4" CONDUIT FROM GANG BOX 2 1/2" CONDUIT FROM GANG BOX DIMENSIONS INDICATE THE CENTER UNE OF OUTLET CLUSTERS. LOCATE OUTLETS AS TIGHT AS POSSIBLE. NOTE FOUR SQUARE BOX *2 3/4- CONDUIT * 1 CONDUIT TERMINATE ABOVE CEILING RECEPTACLES TO BE CENTERED BETWEEN SHELVING STANDARDS RECEPTACLE FOR UNDERSHELF LUM /NAIRE HUBBELL PLUG TRAK WITH (6) RECEPTACLES MODEL P7206112 PLUG TRAK WITH PDB12S BOX, CONTRACTOR SHALL PROVIDE ALL NECESSARY BOXES CONNECTORS, MOUN77NG CLAMPS ETC. FOR A COMPLETE PLUG MOLD SYSTEM. 2 MANAGER DESK ELEVATION SCALE SCALE 3/4' CONDUIT FOR WIRING BETWEEN EACH DOOR FRAME AND CONTROLLER. CONDUIT RUN IS TO BE NO MORE THAN 40' BETWEEN CONTROLLER AND ANTENNAS. (NOTES A AND E) :ffNiINEi\ DOOR OPENING FLOOR LINE SENSORMA71C DIGITAL CONTROLLER IN CE /LING SEE SHEET E1.0 FOR ADDITIONAL INFORMA7TON. (NOTE C) HARDWIRED POWER CONNECTION (NOTE B) EAS DOOR FRAME MOUNT ANTENNA UN /T, MOUNTED ON FACE OF DOOR OPENING. PROVIDE FACE MOUNTED ANTENNA UNIT AS MANUFACTURED BY TYCO INTL. AND INSTALL IN ACCORDANCE WITH TYCO INSTRUCTIONS BIM REFER 70 MANUFACTURER'S INSTALLA770N INS7T?UC77ONS FOR THE CONTROLLER AND ANTENNAS MEL_ SEEFLOORPLAN ON SHEET A1.O FOR EXACT STOREFRONT CONFIGURATION. PLAN SHOWN /5 A TYPICAL LAYOUT SHOWN FOR INFORMATIONAL PURPOSES ONLY FINAL PLACEMENT OF ITEMS MAY VARY SLIGHTLY FROM CONF1GURA770N SHOWN. EAS SYSTEM NOTE& A. 3/4" CONDUIT INTERCONNECT BETWEEN ANTENNA CAVITY AND POWER PACK, 20 FEET MAXIMUM. B. POWER SOURCE 70 BE WITHIN 1 FOOT OF THE POWER PACK. ELECTR /CAL REQUIREMENTS ARE 110 V AC, THREE WIRE, 24 HOUR CIRCUIT WITH LESS THAN .5 V AC BETWEEN NEUTRAL AND GROUND. C. IF POWER PACK IS LOCATED IN CEILING AN ACCESS PANEL OR CEILING 77LE /5 REQUIRED NOT LESS THAN 18" SQUARE. D. AUDIBLE ALARM MAY BE INSTALLED UP TO 30=0" PROM THE POWER PACK. (NOT SHOWN IN DETAIL) E. MAX CABLE RUN FROM "A" ANTENNA TO ELECTRONICS 'i4' POWER PACK IN SOFFIT IS 20'-a " 4 I EAS STEM DETAIL SCALE NOT TO SYSCALE 1 • ETHERNET CABLE (CONNECTION BY OWN DMX PROFUSION XS MEDIA SERVER ZONE 1 I 1 ZONE 2 ZONE 4 Dm P0-11NR I POSE SURLY :ice =I ZONE 1 • MAN MUSIC ZONE ZONE 2 - NOT USED ZONE 3 - NOT USED ZONE 4 - NOT USED E�20L30 MDO3t AMPLFIER CZ LAB 902 ■ ®x E NCH OUT H M E LLB wr H e00w E ICE + wLleE - Ul© J H c INC E MAIM MITRE MODULE SO INPUT SPEAKER UNE 1_ (25V, 70V OR 100V) FROM AMPLIFIER IMILIM' MET] _ s C 0 ®e IN OUT 111111 I1 EQUIPMENT UST • 500' BELDEN WIRE - FOR SPEAKER RUNS * LOWELL FLAT MOUNT SHELF - FOR EQUIPMENT * FURMAN OUTLET STRIP PLUGLOCK - FOR PLUGGING EQUIPMENT IN VOLUME CONTROL IS /NONE WITH SPEAKERS; SEE VC WRING DETAIL BELDEN WIRE USE THE 70V OUTPUT OUTPUT TO SPEAKERS WITH TRANSFORMERS VC WIRING DETAIL SPEAKER TYPE 4 I Y OMX 13201T 100 WATT AREA/R0011 1 I TAP MAN SALES FLOOR NW 5 DMX WIRING DIAGRAM SCALE:NOT TO SCALE 1 REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC DEC 14 2012 City of Tukwila BUILDING DIVISION 7 I NOT TO USED SCALE NOT SCALE SERVICE EQUIPMENT OR SEPARATELY DERIVED SYSTEM ISOLATED GROUND PANELBOARD (SEE NOTE 4) EQUIPMENT GROUND BAR BONDED TO PANELBOARD CAB /NET OUTLET BOX EQUIPMENT GROUND TERMINAL MOUN77NG SCREWS BOND ONLY THE RECEPTACLE FRAME 70 METALLIC OUTLET BOX METALLIC OUTLET BOX ORANGE COLOR FACE IDEN7TF1ES ISOLATED GROUND NOT CONNECTED 717 RECEPTACLE FRAME S/L VER GROUNDED (NEUTRAL) TERMINAL NOTE 3 ISOLATED GROUND TERMINAL IS NOT CONNECTED TO THE RECEPTACLE FRAME AND IS 771EREFORE INSULATED PROM 171E OUTLET BOX GROUNDING PATH ISOLATED GROUND BAR ME BONDED TO (INSULATED mat) PANELBOARD CABINET QDVERAL NOTES APPLICABLE TO 77ES DETAIL A. THIS DETAIL IS DIAGRAMMATIC IN NATURE AND IS NOT INTENDED 70 INDICATE PROPOSED CIRCUIT ROUTING PHASE CONDUCTORS AND RACEWAYS ARE NOT SHOWN FOR CLARITY. ALL RACEWAYS SHALL BE SECURELY BONDED 7V 771E ENCLOSURES 771E RACEWAYS CONNECT. B. A GREEN EQUIPMENT GROUND CONDUCTOR /5 REQUIRED FOR EVERY APPLIANCE BRANCH cRCU /T, EVERY GENERAL- PURPOSE BRANCH CRCU /T, EVERY INDIVIDUAL BRANCH CIRCUIT; AND EVERY MULTI-WIRE BRANCH cRCU /T. UNDER NO CIRCUMSTANCES TILL A METALLIC RACEWAY SYSTEM BE ACCEPTED AS 711E SOLE MEANS OF EQUIPMENT GROUNDING. C GROUNDED (NEUTRAL) CONDUCTORS ARE ONLY REQU /RED FOR 120V LOADS OR POLYPHASE LOADS THAT REQUIRE 120V POWER. D. WHEN INSTALLED PER THE CURRENT NATIONAL ELECTRICAL CODE REQUIREMENTS AT LEAST TWO GROUND CONDUCTOR PATHS ARE REQUIRED; ONE FOR THE RECEPTACLE GROUND AND ONE FOR THE RECEPTACLE. CONDUCTOR LEGEND —GC— GROUNDED CONDUCTOR (NEUTRAL) — EGC— EQUIPMENT GROUNDING CONDUCTOR —IG— ISOLATED GROUNDING CONDUCTOR — GEC — GROUNDING ELECTRODE CONDUCTOR NOTES APPL/CABILE 70 THIS DETAIL: 1. ONLY EQUIPMENT GROUNDING CONDUCTORS SHALL TERMINATE ON THIS EQUIPMENT GROUND BAR. UNDER NO CIRCUMSTANCES SHALL ANY ISOLATED GROUNDING OR GROUNDED CONDUCTOR (NEUTRAL) CONDUCTORS TERMINATE ON THIS BAR. 2. ONLY GROUNDED (NEUTRAL) CONDUCTORS SHALL TERMINATE ON THIS NEUTRAL BAR. UNDER NO CIRCUMSTANCES SHALL ANY ISOLATED GROUNDING OR EQUIPMENT GROUNDING CONDUCTORS TERMINATE ON 77-11S BAR. 3. ONLY /SOILA7ED GROUNDING CONDUCTORS SHALL TERMINATE ON THIS ISOLATED GROUND BAR. UNDER NO CIRCUMSTANCES SHALL ANY EQUIPMENT GROUNDING OR GROUNDED CONDUCTOR (NEUTRAL) CONDUCTORS TERMINATE ON THIS BAR. 4. UNLESS INDICATED OTHERWISE, GRCU /T5' SERVED BY THIS PANEL SHALL BE ROUTED IN DEDICATED RACEWAYS AND SHALL NOT BE COMBINED IN THE SAME RACEWAY WI771 NON - ISOLATED GROUND GRCU /TS: 5. ISOLATED GROUNDING CONDUCTOR /5 PERMITTED TO PASS THROUGH PANELBOARDS BUT MUST TERMINA7E AT THE SERVICE EQUIPMENT GROUNDING TERMINAL AR AT THE GROUNDING TERMINAL OF THE SEPARATELY DERIVED SYSTEM, IF APPLICABLE, UNLESS INDICATED OTHERWISE. HUBBELL PLUG TRAK WITH (6) RECEPTACLES MODEL ,fP7206112 PLUG TRAK WITH PDB12S BOX CONTRACTOR SHALL PROVIDE ALL NECESSARY BOXES CONNECTORS, MOUN77NG CLAMPS; ETC. FOR A COMPLETE PLUG MOLD SYSTEM. JUNCTION BOX FOR SHOPPER TRACK IG IG a Aumil r W■ JY/NC77ON BOX FOR BROADBAND/EXTANT JUNCTION BOX FOR /NT /CART CC1, CC2, CC3 INSTALL HOLD UP BUTTON BELOW COUNTER. VERIFY EXACT LOCA770N WITH OWNER'S REPRESENTA77VE PRIOR 70 ROUGH -IN 1 * 1171.11174 JUNC77ON BOX FOR APPS PC/ DM JACK/ L1,L2 JACK RECEPTACLE FOR UNDERSHELF LUM /NAIRE DIGITAL ZONE CONTROLLER, SEE M20 FOR SITE SPECIFIC PLACEMENT AND QUAN/77TY 1 3 IMANAGERS NOT DESK PLAN SCALE TO SCALE ELECTRICAL CONTRACTOR SHALL PROVIDE A DED /CA 7ED DUPLEX RECEPTACLE AT AUDIO EQUIPMENT MUSIC EQUIPMENT SHELF SEE PLAN PANEL LOCATION. SEE PLAN FOR EXACT LOCA7TON AND HEIGHT 3/4" CONDUIT WITH PULL STRING IN WALL BY ELECTRICAL CONTRACTOR. WEST PENN 252245 (RUN TO SPEAKERS) 1. l 0 M WRIFY IF REQUIRED 7O MUTE TENANT'S MUSIC/STEREO WHEN FIRE ALARM SYSTEM /5 ACTIVATED WITH LANDLORD'S FIRE ALARM SYSTEM CONTRACTOR AND TENANT'S ARCHITECT PRIOR TO B /D. WI r In B N.8 AUDIO SYSTEM VENDOR FURNISHED, ELECTRICAL CONTRACTOR INSTALLED MUSIC EQU /PMENT SHELF AT +/- 7 =0" A.F.F. SEE PLAN FOR LOCA770N. SPEAKERS MOUNTED IN SALES AREA ARE FURNISHED BY 771E CHILDREN'S PLACE FOR INSTALLA7TCN BY THE ELECTRICAL CONTRACTOR. COORDINATE LOCATIONS WITH THE CHILDREN'S PLACE REPRESENTATIVE PRIOR 70 ROUGH -IN. VOLUME CONTROL FUR/AWED BY AUDIO SYSTEM VENDOR FOR INSTALLATION BY ELECTRICAL CONTRACTOR, VER /FY EXACT MOUNTING LOCA770N Wf771 7CP PROJECT MANAGER PRIOR 70 INSTALLA770N, MOUNT AT +5=0" A.F.F. SINGLE GANG WALL BOX MOUNTED BEH /ND SOUND SYSTEM EQUIPMENT BY ELECTRICAL CONTRACTOR. SEE PLAN FOR LOCATION 18 GA PLENUM RATED SPEAKER WIRE FURNISHED BY AUD /O SYSTEL! VENDOR FOR INSTALLA770N BY ELECTRICAL CONTRACTOR WEST PENN 252248 (RUN TO VOLUME CONTROL) NOTES: 1. ALL ELECTRICAL BOXES AND CONDUIT, SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. 2. THE AUDIO SYSTEM VENDOR WILL FURNISH ALL AUDIO EQUIPMENT, WIRING AND SHELVING FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. 3. THE CHILDREN'S PLACE WILL FURNISH THE SPEAKERS. THE ELECTRICAL CONTRACTOR SHALL INSTALL SPEAKERS, AUDIO EQUIPMENT, AND PROVIDE FINAL TERMINATIONS. 4. REFER TO WIRING DIAGRAM 5/E5.0 FOR ADDITIONAL INFORMATION. 1 MUSIC SHELF ELEVATION SCALE: SCALE 8 ISOLATED GROUND RECEPTACLE DETAIL 'ISOLATES SCALE EL1)11'iI RECEIVED CITY OF TUKWILA DEC 0 6 2012 PERMIT CENTER 9 I NOT USED SCALE:NOT TO SCALE © 2011 ARGVISION, INC THIS DRAWING, THE DESIGN INDICATED, THE FORMAT AND ARRANGEMENTS ARE THE PROPERTY OF FREDERICK J. GOGLIA, NCARB, RDI. ANY USE OR REUSE OF ORIGINAL OR ALTERED DESIGN MATERIALS BY THE CLIENT, AGENTS OF THE CLIENT OR OTHER PARTIES WITHOUT THE REVIEW AND WRITTEN APPROVAL OF THE DESIGN PROFESSIONAL SHALL BE AT THE SOLE RISK OF THE OTHERS. FURTHERMORE THE CLIENT AGREES TO DEFEND, INDEMNIFY AND HOLD THE DESIGN PROFESSIONAL HARMLESS FROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES, EXPENSES AND ATTORNEY'S FEES ARISING OUT OF MODIFICATION OR REUSE OF THESE MATERIALS. THE GENERAL CONTRACTOR AND /OR ALL SUB - CONTRACTORS WORKING FROM THESE PLANS AND SPECIFICATIONS ARE NOT TO SCALE SUCH INFORMATION BUT TO CONTACT THE ARCHITECT OR HIS REPRESENTATIVE REGARDING MEASUREMENTS, IF SUCH MEASUREMENTS DO NOT APPEAR CORRECT, ADD UP PROPERLY OR SCALE CORRECTLY TO THE INDICATED SIZE. THESE DRAWINGS WERE COMPLETED UNDER THE DIRECT SUPERVISION OF: FREDERICK J. GOGLIA DATE ISSUE REV DATE ISSUE 10/26/11 - TC' REV I EkM *1 10/26/11 - LL REVIEVI #1 11/01/12 - FOR PERMIT ARCHITECT ROBERT L. QUEATHEM ENGNE6 1950 CRAIG ROAD, Sl4TE 300 ST. LOIN, MO 63146 PH. (314) 415 -2400 FAX (314) 415 -2300 www.arcv.com STORE TYPE TECH 2 — 3 2010 -10 W8 PROJECT SQUARE FOOTAGE SALES SUPPORT TOTAL 2833 5F 565 5F 3318 SF PROJECT THE CHILDREN'S STORE 1322 SOUTHGENTER MALL SEATTLE, WA 18188 SCALE AS NOTED DRAWN BY f<RG ARGVISION PROJECT # 120118 CHECKED BY SHEET TITLE ELEGTRIGAL DEALS SHEET NUMBER 5 .0 SINGLE LINE DIAGRAM NO SCALE VARIABLE VOLUME AIR TERMINAL (TYPICAL OF 2) O18/2 —= 18/2 18/2 MOUNT OUTSIDE AIR DEVICE ON ROOF FOR NON -MALL Supply LOCATIONS Air Duct 1 BUTTON OVERRIDE ® OV '-18/2 x2 c-18/2 x2 SLP 0000 CAT -5 CABLE (1)UPS CABLE 120VAC POWER DEDICATED CIRCUIT (LABEL EMS-2) f (3)18/2 (1)GND PIP (1) 18/10 (1) 18/4 LCP 120VAC POWER, 111 DEDICATED CIRCUIT (LABEL EMS1) PLUS ALL SWITCHED LOADS CUSTOMER NETWORK OR CELL MODEM KEYED NOTES 1 ALL DZCs SHALL BE MOUNTED IN THE SAME ROOM AS INDICATED IN MECHANICAL DRAWINGS. OINSTALL ON LEFT SIDE (LOOKING INTO THE STORE) INTERIOR WING WALL. SIEMENS PROJECT MANAGER OR TCP REP ON SITE MUST BE CONTACTED BEFORE INSTALLATION VERIFY LOCATION. KOPTIONAL CO2 SENSOR. :ii: PROVIDE GROUNDED 24VAC TO POWER DZC. 1 -1/2" EMT CONTROL PANEL MOUNTING DETAIL NO SCALE KEYED NOTES 0 MAXIMUM FLOOR TO TOP OF ANY PANEL 7518. PANELS MAY BE LOWERED TO MET EXISTING CONDITIONS. OMAXIMUM DISTANCE BETWEEN SLP AND PIP 6- TO ACCOMMODATE INTERCONNECTING CABUNG. />N0 LESS THAN 1 -1/2' (THIS SIZE IS CRITICAL) DZC TO SPACE TEMP SENSOR NO SCALE 11 DZC TO DUCT TEMP. SENSOR NO SCALE } m (/3 N N N CD 0 N OPTIONAL AS SPECIFIED BY MECHANICAL DWGa CO2 SENSOR (OPEN VIEW) INSTALL RESISTOR 18/2 CABLE X2 DZC TO CO2 SENSOR WIRING DETAILS N N .- . O 0< 0< 0 z> 2 O I J O W O <1-0 0= 0 Z U I. N (� lIIlIFI+I0I 1 1 J 1 1 I 1 1 ci 1111101 DZC TO ROOFTOP WIRING DETAIL NO SCALE a> o as v c 0 a 0 0 -0 0 0 E N 0 IS IA 3 EMS SCHEDULES DEVICE SCHEDULES SYMBOL DEVICE QUANTITY DEVICE LOCATION DEVICE CABLE TYPE NOTES SHIELDED, STRANDED, PLENUM RATED CARBON DIOXIDE SENSOR (OPTIONAL) AS REQUIRED BY CODE MAIN SPACE ONLY WHEN REQUIRED BY CODE 18/2 (x2) D® DUCT TEMPERATURE SENSOR 1 PER DIGITAL ZONE CONTROLLER MAIN SUPPLY AIR DUCT 1812 1 '.:-' DIGITAL ZONE CONTROLLER 1 PER ROOFTOP UNIT (AND ADDITIONAL HVAC) CLUSTERED, REFER TO MECHANICAL DRAWING FOR LOCATION 18/10 2 ® ENERGY METER US SITES 1 PER MDP AS SPECIFIED BY DESIGN ENGINEER 24/1P ( COMMUNICATION TO SLP) 3 ® ENERGY METER CANADIAN SITES 1 PER MDP AS SPECIFIED BY DESIGN ENGINEER 24/1P (COMMUNICATION TO SLP) AND 18/2 3 ® HUMIDISTAT, IF SUPPLIED BY RTU MFGR. AS SPECIFIED IN MECHANICAL SCHEDULE BESIDE REMOTE ZONE SENSOR FOR SERVING RTU AS SPECIFIED BY MFGR. TAPPAN /2469ATIM -CMP CAT5 24AWG/ 4 -UTP UNSHIELDED SOUD CONDUCTOR TWISTED PAIR BELDEN 1583A CATS ® UGHTING CONTROL PANEL 1 OR MORE (REFER TO LCP SCHEDULE FOR DETAILS) NEAR BREAKER PANEL(S) FEEDING CONTROLLED UGHTING CIRCUITS (18/10 & 18/2) PER PANEL •Z OUTSIDE SENSING DEVICE 1 (ONLY NON -MALL LOCATIONS) ROOF 18/2 (X2) ® OCCUPANCY SENSOR 1 EACH RESTROOM AND FITTING ROOM MOUNTED ON CEIUNG OF RESTROOM AND FITTING ROOM PER MFG. INSTRUCTIONS ® (1) BUTTON OVERRIDE 1 NEXT TO ADT PANEL WHENEVER POSSIBLE 18/2 (x2) ® POWER INTERFACE PANEL 1 ELECTRICAL ROOM (UNDER SLP) (1) 18/2, OTHER (SEE POINT TO POINT DWGs) 5 0 SCREAM LOGIC PANEL 1 ELECTRICAL ROOM VARIES PER CONNECTED DEVICE ® ZONE TEMPERATURE SENSOR 1 PER DIGITAL ZONE CONTROLLER IN THE ZONE, AT 72. AFF, PREFERABLY ON A COLUMN NEAR RETURN AIR GRILL 18/2 NOTES 1. ONE DUCT SENSOR, 1 PER DIGITAL ZONE CONTROLLER (DZC) 2. ONE DZC FOR EACH HVAC EQUIPMENT REQUIRING THERMOSTATIC CONTROL (RTU, HEAT PUMPS, ETC.) 3. MOUNT EM CTS ON 3 -PHASE BUSS BARS AT MDP AFTER UTIUTY METER AND BEFORE TRANSFORMERS AND BRANCH CIRCUITS. 4. M.C. SHALL INSTALL LOW VOLTAGE CABLE IN RACEWAYS PROVIDED BY EC. AND TERMINATE BOTH ENDS. - UNE VOLTAGE WIRING AND TERMINATIONS BY EC. 5. EC. SHALL PROVIDE AND INSTALL A DEDICATED 120V, 20A CIRCUIT TO POWER THE PIP. LABEL BREAKER EMS -2 6. INTERCONNECTING CABLING BETWEEN THE PIP AND SLP SHALL BE INSTALLED BY THE M.C. AND THE GROUND CONNECTION BY THE E.C. 7. WITH THE EXCEPTION OF THE OSD AND ENERGY METERS THE M.C. SHALL TERMINATE ALL LV CABLES IN THE SLP INSTALLATION SUMMARY GC TO FILL OUT EMS READINESS CHECKUST. RETURN TO GC PM FOR VERIFICATION. COMMISSIONING WILL BE SCHEDULED AT TIME OF IT INSTALLATION. LOW VOLTAGE WRING FOR TELEPHONE, DATA, SOUND, TV AND SECURITY SYSTEMS WHICH ARE ENCLOSED IN BUILDING PAR777YONS OR IN ANY WAY MADE INACCESSIBLE BY CONSTRUC710N, SHALL BE ENCASED IN A CONDUIT. 7HE CONDUIT NEED NOT TERM /NA7E IN A BOX OR f7771NGS AS LONG AS NORMAL PRECAU77ONS ARE TAKEN TO PROTECT 7HE CONDUCTORS VERNON HILLS CODE OF ORDINANCES 97 -45 ARTICLE IX SEC770N 725- 54(E). SEC770N 800- 52(F), SEC770N 820- 50(A). ALL LOW VOLTAGE CABLES 7O COMPLY M7H NEC 725 -38(E) AND 800 -30. COAXIAL CABLES NEC 820 -50. CABLE SCHEDULES CABLE SIZE TYPE MFG./MODEL 18/2 18AWG /2- CONDUCTOR SHIELDED, STRANDED, PLENUM RATED BELDEN/6300FE NON - PAIRED COMTRAN /3644 TAPPAN /1880AB2M -CMP 18/2 (600V) 18AWG /2- CONDUCTOR SHIELDED, STRANDED, NON PLENUM, TC -600V BELDEN 27325AS 18/10 18AWG /10- CONDUCTOR UNSHIELDED, STRANDED, PLENUM BELDEN/6308UE NON- PAIRED LAKE CABLE/P1810C -WIN TAPPAN /1880AB1O -CMP 24/1P 24AWG /1- TWISTED PAIR SHIELDED, STRANDED, PLENUM RATED, BELDEN /82841 PAIRED TWISTED PAIR LAKE CABLE/PF242CS TAPPAN /2469ATIM -CMP CAT5 24AWG/ 4 -UTP UNSHIELDED SOUD CONDUCTOR TWISTED PAIR BELDEN 1583A CATS GENERAL NON —EMS CONTROLS NOTES 1. UFE SAFETY AND FIRE ALARM SYSTEMS I. LIFE SAFETY AND FIRE ALARM SYSTEMS ARE NOT PART OF THE EMS SYSTEM AND SHALL BE FURNISHED AND INSTALLED AS SPECIFIED IN THE MECHANICAL AND ELECTRICAL BID DOCUMENTS. II. MECHANICAL EQUIPMENT SHUTDOWN SHALL BE WIRED AS TO NOT AFFECT THE EMS SYSTEM. 2. MANUFACTURER SUPPUED HUMIDITY CONTROLLERS I. DEHUMIDIFYING ROOFTOP UNITS a. SOME ROOFTOP UNITS MAY COME EQUIPPED WITH A DEHUMIDIFICATION CYCLE AND SPACE HUMIDITY SENSOR. THIS SENSOR SHALL BE INSTALLED IN ADDITION TO THE EMS SYSTEM AND ACCORDING TO THE MANUFACTURER'S INSTRUCTION. LOW VOLTAGE CABLING TYPICAL (2) RTU STORE w/ SPACE MOUNTED ZONE SENSORS AND (1) ENERGY METER: 560' - 18/2 50' - 18/10 50' - 22/2 LOW CAP. COMM WIRE EACH CO2 SENSOR ADD: 160' - 18/2 EACH OUTSIDE AIR SENSOR ADD: 100' - 18/2 KEY SWITCH AT FRONT ENTRANCE ADD: 260' - 18/2 18/2 CABLE ON I/O MODU LE SIP GND IN -# IN -# 1 a 1b 1- BUTTON OVERRIDE O NEAR SECURITY KEYPAD OV AT FRONT DOOR (REAR VIEW) a ,b TYPICAL OF 3 CONNECTIONS 1- COMMON, 2 SWITCHED LEGS (SEE EMS POINT TO POINT DWGs) 1 BUTTON OVERRIDE NO SCALE FOR NON —MALL LOCATIONS OUTSIDE SENSOR DEVICE (ON ROOF) OUTSIDE UGHT SENSOR (OLD LK WHT WHT 18/2 CABLE LOCATED IN SLP 1r I C 64-WHT :I® ®- BLK/BL K- _ ®-WHT • +OA -OA /OL +OL it 0 0 0 0 0 0 OUTSIDE AIR TEMPERATURE SENSOR (0A) /OSc \OUTSIDE SENSING DEVICE MOUNTING AND WIRING DETAILS NO SCALE 8' 0 0 00 00 5' POINT OUTSIDE UGHT SENSOR, NORTH 1 ROOF LINE 1/2' RIGID CONDUIT SECURE TO BUILDING STRUCTURE J co Od5 OD cc cc O w c 0 a 0 N tcp- ems — prototypical— Rev3.dwg Drawing File Name /Origin: 24/1P COM CABLE PLENUM RATED MAIN DISTRIBUTION PANEL ENERGY METER 0 u BOX i ENERGY METER INSTALLATION DETAILS NO SCALE ADDRESS 32 1 1EZI 2 2: 4 3 8 4 . 16 32 6 5 ON [WI 3J 18/2 SHIELDED RATE FOR 600V MOVE SWITCH #32 TO 'ON' POSITION KEYED NOTES OWHEN TRANSITION FROM 18/2 TO 24/2 CAN'T BE AVOIDED THE FOLLOWING PRECAUTIONS MUST BE TAKEN: 1. MOUNT A SPUCING BOX NEAR TO THE MDP. II.TERMINATE WIRES WITH SEALANT FILLED CONNECTORS (DOLPHINS OR SIMILAR) III.OBSERVE POLARITY GENERAL NOTES: 1. INSTALL ENERGY METER AT MDP AFTER UTIUTY METER AND BEFORE TRANSFORMERS AND BRANCH CIRCUITS TO CAPTURE TOTAL BUILDING LOAD. 2. AVOID SPUCING THE 600V RATED COMM CABLE, IF LONG ENOUGH TO REACH SLP. MOUNTING THE ENERGY METER AT THE MDP BI BLACK LEAD LED FLASHES GREEN WHEN PROPERLY INSTALLED BLACK CT BLACK CT CI FUSE FUSE FUSE BLACK RED YELLOW PHASE VOLTAGE SENSING LEADS WITH CTS (TYPICAL) RED CT -F —YELLOW CT 0 v N REVIEWED F01 -1 COMPLIANCE WITH NFPA70 -NEC DEC 14 2012 City of Tukwila BUILDING DIVISION Li)W41 RECEIVED CITY OF TUKWILA DEC 06 2012 PERMIT CENTER © 2011 ARCVISION, INC THIS DRAWING, THE DESIGN INDICATED, THE FORMAT AND ARRANGEMENTS ARE THE PROPERTY OF FREDERICK J. GOGLIA, NGARB, RDI. ANY USE OR REUSE OF ORIGINAL OR ALTERED DESIGN MATERIALS BY THE CLIENT, AGENTS OF THE CLIENT OR OTHER PARTIES WITHOUT THE REVIEW AND WRITTEN APPROVAL OF THE DESIGN PROiC i ZONAL SHALL BE AT THE SOLE RISK OF THE OTHERS. FURTHERMORE THE CLIENT AGREES TO DEFEND, INDEMNIFY AND HOLD THE DESIGN PROFESSIONAL HARMLESS FROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES, EXPENSES. AND ATTORNEY'S FEES ARISING OUT OF MODIFICATION OR REUSE OF THESE MATERIALS. THE GENERAL CONTRACTOR AND /OR ALL SUB - CONTRACTORS WORKING FROM THESE PLANS AND SPECIFICATIONS ARE NOT TO SCALE SUCH INFORMATION BUT TO CONTACT THE ARCHITECT OR HIS REPRESENTATIVE REGARDING MEASUREMENTS, IF SUCH MEASUREMENTS DO NOT APPEAR CORRECT, ADD UP PROPERLY OR SCALE CORRECTLY TO THE INDICATED SIZE. THESE DRAWINGS WERE COMPLETED UNDER THE DIRECT SUPERVISION OF: FREDERICK J. 606LIA DATE ISSUE REV DATE I55UE 10/26/11 - TOP R1=V I EM # 10/26/11 - LL REV I EIN # 1 11/01/12 - FOR PERMIT ARCHITECT ROBERT L. QUEATHEM Et VEER 1950 CRAIG ROAD, SITE 300 ST. LOUIS, IAD 63146 PH. (314) 415 -2400 FAX (314) 415 -2 0 www.ercv.com STORE TYPE TECH 2 — E3 2010 -10 PROJECT SQUARE FOOTAGE SALES SUPPORT TOTAL 2833 SF 565 5F 3318 5F PROJECT THE CHIJI'F�NS. STORE 1322 SOUTHGENTER MALL SEATTLE, INA g8ISS SCALE AS NOTED DRAWN BY ND ARCVISION PROJECT # 120118 CHECKED BY RF SHEET TITLE ENERGY MANAGEMENT SYSTEM (USA S I TES) SHEET NUMBER ENERGY ANALYSIS COMPLIANCE CALCULATIONS 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential S PRJUM Project Summa onna 1Mchlnntnn State Enerav Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address Date 10/25/2012 - 633 Southcenter Mali For Building Department Use Tukwila, WA 98188 Applicant Name: The Children ' s Place Applicant Address: Applicant Phone: Project Description LI New Building Addition Alteration Lj Plans included Refer to WSEC Section 1513 for controls and commissioning requirements. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Intel-1'0r Li htin e S mma` LTG =INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised Decem Project Info Project Address Date 10/25/2012 633 Southcenter Mall For Building Department Use Tukwila, WA 98188 Applicant Name: The Children 'a Place Applicant Address: Applicant Phone: Project Description LI New Building Addition Alteration Lj Plans included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive (e) Lighting Power Allowance ;