HomeMy WebLinkAboutPermit M12-012 - WESTFIELD SOUTHCENTER MALL - NATIONAL UNIVERSITYNATIONAL UNIVERSITY 152 SOUTHCENTER MALL M12 -012 City otTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 152 SOUTHCENTER MALL TUKW Project Name: NATIONAL UNIVERSITY Permit Number: M12 -012 Issue Date: 05/11/2012 Permit Expires On: 11/07/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: LESLIE LOMBARD Address: 3701 WILSHIRE BL, STE 414 , LOS ANGELES CA 90010 Email: LESLIEL @URBAN- CONCEPTS.COM Contractor: Name: WILLIAMS MECHANICAL INC Address: 3903 SMITH AV , EVERETT WA 98201 -4549 Contractor License No: WILLIMI088PA Phone: 323 966 -2610 Phone: 425 303 -0828 Expiration Date: 10/01/2013 DESCRIPTION OF WORK: REPLACE EXISTING HEAT PUMP AND INSTALL NEW FAN COIL UNIT, DUCTS, AND CEILING DIFFUSERS. Value of Mechanical: $9,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $293.81 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t : - - = man_ ce of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this Signature: Print Name: MCLIpiAAS Date: I 1 \� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -012 Printed: 05 -11 -2012 PERMIT CONDITIONS Permit No. M12-012 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 20: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: IMC -4/10 M12 -012 Printed: 05 -11 -2012 21: These plans were reviewed byliector 511. If you have any questions, plea.' Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M12 -012 Printed: 05 -11 -2012 #• CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION g2nL,'1 --WLo King Co Assessor's Tax No.: 43'9998624 Site Address: :: s Southcenter Mall Suite Number: 612 Floor: 1 Tenant Name: National University PROPERTY OWNER Name: Westfield, LLC Address: 11602 Wilshire Blvd. 1 lth Floor City: Los Angeles State: CA Zip: 90025 CONTACT PERSON — person receiving all project communication Name: Leslie Lombard Address: 3701 Wilshire Blvd. Ste. 414 City: Los Angeles State: CA Zip: 90010 Phone: (323) 966 -2610 Fax: Email: lesliel @urban- concepts.com New Tenant: 0 Yes ❑ .. No MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Replace existing heat pump, install new fan coil unit, ducts and ceiling diffusers. 000 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas ❑ Other: H:\ Applications \Forms- Applications On Line \2011 Applications \Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 15 Floor furnace Suspended/wall/floor mounted heater 1 Appliance vent Repair or addition to heat/refrig/cooling system 1 Air handling unit <10,000 cf n 1 Unit Type Qty Air handling unit >10,000 cfm 15 Evaporator cooler Ventilation fan connected to single duct 1 Ventilation system Hood and duct 1 Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 15 Thermostat Wood/gas stove Emergency generator Other mechanical equipment 1 Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING WNER OR AUTHORIZED AGENT: Signature: Date: Print Name: Leslie Lombard Day Telephone: (323) 966 -2610 Mailing Address: 3701 Wilshire Blvd. Ste 414 Los Angeles CA 90010 City State Zip H:\Applications \Forms - Applications On Line \2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M12 -012 Address: 152 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 01/25/2012 Applicant: NATIONAL UNIVERSITY Issue Date: Receipt No.: R12 -01559 Initials: User ID: Payee: WER 1655 Payment Amount: $235.05 Payment Date: 05/11/2012 11:43 AM Balance: $0.00 BRADLEY WILLIAMS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 09198G ACCOUNT ITEM LIST: Description 235.05 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 235.05 Total: $235.05 doc: Receiot -06 Printed: 05 -11 -2012 Ci* of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: /hvww. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -00253 Initials: JEM Payment Date: 01/25/2012 User ID: 1165 Total Payment: 170.39 Payee: LESLIE LOMBARD SET ID: S000001681 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount EL12 -0062 M12 -012 PG12 -013 TOTAL: 70.42 58.76 41.21 70.42 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 170.39 TOTAL: 170.39 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 70.42 99.97 TOTAL: 170.39 INSPECTION NO. INSPECTION RECORD Retain a copy with permit ccO fl k2 -OI PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 les (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 �- Project: t%) i\--1- 1 Op..; k i. 11 Ni i U s' 2s rr L Type of Inspection: i S M 0J 46 - S t-A l t i ∎> 0- 4-41\) Address: t `6 7. so ,4- rAA+,t Date Called: � 1N nt. - Special Instructions: G'•-5v / Date Wanted:. h 2-7 -1 Z Vim; p.m. Requester: Phone No: '71-)7 - -0ii - i5 ?5 MApproved per applicable codes. Corrections required prior to approval. /5" COMMENTS: ? ( . 7 r W\ .1--\ 0 . i d e/ i:-----; nJ a \ Inspect& / Date: INSPECTION FEE REQlJ1RED. Pr or to next inspection, fee must be 'd at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION .6300. Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 ' Permit Inspection. Request Line (206) 431 -2451 AA(2 -0 2_ Proj ct:; - ma, )AJAv, JA.. JuS Type of Inspection: . 1'Pf -i.la I Address. 1 Date Called: Special Instructions:. 0' ) /k Date Wanted:. ,a.m. Requester: Phone No: proved ;.per applicable codes. Corrections required prior to approval. COMMENTS: 3so v o �--- 7J Inspet tor: Dater } 7 — 0' REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO." " PERMIT NO. CITY.OF TUKWILA BUILD G DIVISION 6300 Southcenter: Blvd:; #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection ,'Request Line (206) 431 -2451 M 2 -DMZ Projec '�! u JQISt Type Inspection: ,�) UG +t-- s /V/ Atat Ad "fires •- ` ' ' AA � (Date lecf j� .r Speciallnstructions : Date Wanted: 4 - .- ' 1,1_ C- a:m. p.m. Requester: Ph '70'2_ -- 57°1 ---S-J -Approved' per ;applicable codes. ElCorrections required prior to approval. // COMMENTS:: lnspecto kdk, REINSPECTION. FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. /tit ?,--- INSPECTION RECORD Retain a copy with permit INSPECTION,NO. PERMIT NO. CITY OF'TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.; #100, Tukwila. WA 98188 rz., (206) 431 -3671 Permit Inspection Request Line (206) 431 -2451 Proje t: c,, I \ . J1S' Type of Inspection: • ( .v c3 6 W ��'' L4 i Address:.: , e / Date Called: Special Instructions:L ITC:-13- /1 C II- .e- - / ..cam •. j , Date Wanted:. /�a.m= Requester: Phone No: ? Approved per applicable codes. Corrections required prior to approval. 7Q COMMENTS:. Inspegtor: Date REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 c1-0 I 1/2- c)/ Project: %% op i,1L 2 /,v,16 -- PS'i -/ Type of Inspection:, (r'el > /ey 6 -/ .../ Address: : %..7 -.-' :.So t?,VT /Y/s9 /i Date Called: Special Instructions: Date Wanted:. .5 - / 7 - /Z m: p.m: Requester: Phone No: 4425 - 75'1- G 45<51 Approved per applicable codes. E Corrections required prior to approval. COMMENTS:j,) Q'�. 0 a /44-re 571P01-� Inspector' Date: /7- I,/ !REI PECTION FEE REQUIRE). Prior'to next inspection. fee must be pa;d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 3- INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit (5/).. /3- -F-ix? PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: fen�w 1 V ►� rvcvs; Ill Sprinklers:. Type of Inspection: AtecLi . F0-14 1 1 FA Ft`ic, 1 Address: / c� f0 t.L‘LeV„ I.,,, Suite #: Mk 1. I Contact Person: Special Instructions: I Phone No.: 'Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers:. Fire Alarm: Hood &Duct: Monitor: Pre -Fire: fret . F1'1,1( I Ok. I ri F', ,, , I d < f .� .J Needs Shift Inspection: Sprinklers:. Fire Alarm: Hood &Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Ayv1 S 1 1 Date: G -.1.1_, Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 *PERMIT COORD COPO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -012 DATE: 01/25/12 PROJECT NAME: NATIONAL UNIVERSITY SITE ADDRESS: 152 SOUTHCENTER MALL X _ Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued 4135DEPPARTMENTS: ��`�� din ivission ■ Public Works AW "Fire Prevention c Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 01/26/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route rT Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/23/12 Approved Approved with Conditions E Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name WILLIAMS MECHANICAL INC UBI No. 601413863 Phone 4253030828 Status Active Address 3903 Smith Ave License No. WILLIMI088PA Suite /Apt. License Type Construction Contractor City Everett Effective Date 10/1/1992 State WA Expiration Date 10/1/2013 Zip 982014549 Suspend Date County Snohomish Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WILLIPH136Q4 WILLIAMS PLUMBING & HTG INC Construction Contractor Boiler /Steam Fit /Prot Piping Plumbing 11/24/1987 11/19/1992 Archived Business Owner Information Name Role Effective Date Expiration Date WILLIAMS, DEBORAH KAY Agent 09/27/2011 Bond Amount WILLIAMS, BRADLEY PATRICK President 01/01/1980 1977877 WILLIAMS, DEBORAH KAY Secretary 01/01/1980 WILLIAMS, DEBORAH KAY Treasurer 09/27/2011 INS CO OF THE WEST ZUCCARINI, MICHAEL J Agent 01/01/1980 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 CHOE HANOVER INS. 1977877 10/01/2010 Until Cancelled $12,000.0009/15 /2010 3 INS CO OF THE WEST 2271807 10/01/2007 Until Cancelled 10/23/2010 $12,000.00 10/01/2007 2 CBIC 634038 09/30/2001 10/01/2007 $6,000.0009/25/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 17 CHARTER OAK FIRE INSURANCE COM 4TC00427P552C0F0909/30/2010 09/30/2012 $1,000,000.0009 /13/2011 16 CONTINENTAL WESTERN INSURANCE CWP2643064 09/30/2007 09/30/2010 $1,000,000.0009 /23/2009 15 CONTINENTAL WESTERN INS CO CWP2643064 09/30/2006 09/30/2007 $1,000,000.0009 /26/2006 14 WEST AMERICAN INS CO BK053242160 09/30/2004 09/30/2007 $1,000,000.00 09/18/2006 https: / /fortress.wa. gov /lni /bbip /Print.aspx 05/11/2012 LANDLORD COMMENTS I. SCHEDULE BALANCING WITH TI-4E LANDLORD'S FIELD REPRESENTATIVE. PROVIDE A COPY OF THE APPROVED TEST AND BALANCE REPORT TO THE LANDLORD. 2. EXCEPT FOR FINAL RUNOUT DEVICE, ALL DUCTWORK, REGARDLESS OF AGE, SHALL BE RIGID SHEET METAL. FIBERGLASS DUCTBOARD IS NOT ACCEPTABLE. REPLACE EXISTING DUCT AS MAY BE ACCEPTABLE_ NO ALTERNATE FOR FIBERCsLASS WILL BE CONSIDERED. 3. MAXIMUM AGGREGATE LENGTH OF FLEX DUCT IS 5 FEET. ANY CHANGE IN DIRECTION THAT MIGHT OCCUR IN FLEX DUCT RUN MUST BE IN RIGID SHEET METAL ELBOWS. MECHANICAL PLAN CHECK NOTES 1. ALL HVAC SYSTEMS SHALL MEET THE CONTROL REQUIREMENTS PER ALL STATE AND LOCAL CODES. 2. A MAINTENANCE LABEL SHALL BE AFFIXED TO MECHANICAL EQUIPMENT AND A MAINTENANCE MANUAL SHALL BE PROVIDED FOR THE OWNER'S USE. THE LABEL SHALL CLEARLY INDICATE THE ROUTINE MAINTENANCE ACTIONS WHICH MUST BE PERFORMED TO MAINTAIN THE EQUIPMENT IN EFFICIENT OPERATING CONDITION, OR INDICATE BY NUMBER WHICH MAINTENANCE OR OPERATIONS MANUALS EXPLAIN THE MAINTENANCE REQUIREMENTS IN GREATER DETAIL. 3. ALL HVAC EQUIPMENT AND APPLIANCES SHALL MEET THE REQUIREMENTS PER ALL STATE AND LOCAL CODES. MANUFACTURERS AND SUPPLIERS SHALL PROVIDE ALL NECESSARY DATA FOR COMPLIANCE. PROVIDE COMPLIANCE CERTIFICATES WITH EQUIPMENT SUBMITTALS. 4. ALL DUCTWORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN ACCORDANCE WITH THE STANDARDS ADOPTED BY CHAPTER 6 OF THE CURRENT IMC (SMACNA STANDARDS ARE ACCEPTABLE PROVIDED THEY MEET OR EXCEED INC) 5. ALL PIPING AND DUCTWORK SHALL BE INSULATED CONSISTENT WITH THE REQUIREMENTS OF ALL STATE AND LOCAL CODES AND CHAPTER 6 OF THE CURRENT I.M.C. INSULATION MATERIALS SHALL MEET ALL STATE AND LOCAL. CODE REQUIREMENTS. 6. ALL DOORS AND WINDOWS SHALL MEET THE MINIMUM INFILTRATION REQUIREMENTS PER ALL STATE AND LOCAL CODES. 1. ALL HVAC SYSTEMS SHALL MEET THE VENTILATION REQUIREMENTS PER ALL LOCAL AND STATE CODES. 8. AREA SEPARATION WALLS: A. PENETRATIONS OF FIRE - RESISTIVE WALLS, FLOOR - CEILINGS AND ROOF - CEILINGS SHALL BE PROTECTED AS REQUIRED IN CURRENT IBC. B. NO RANGE HOOD VENTS, DRYER VENTS, COMBUSTION VENTS, OR HEATING DUCTS ARE PERMITTED IN AREA SEPARATION WALLS. 9. PROVIDE SMOKE DETECTORS FOR AIR MOVING SYSTEMS EXCEEDING 2000 CFM AT MAIN SUPPLY DUCTS PER IMC 609. PROVIDE PHOTOELECTRIC TYPE DETECTOR THAT 15 WIRED TO SHUT DOWN THE POWER SOURCE OF THE AIR MOVING DEVICE. DETECTOR SHALL BE UL AND SFM LISTED FOR THE APPROPRIATE DUCT VELOCITY, TEMPERATURES, PRESSURES AND HUMIDITIES OF THE SYSTEMS. ALSO PROVIDE COORDINATION WITH ELECTRICAL AND FIRE ALARM CONTRACTORS TO ENSURE COMPLIANCE WITH NFPA 12. (REMOTE INDICATION, ANNUCIATION, AND ALARM STATUS MUST BE PROVIDED PER NFPA 12) 10. FIRE AND /OR SMOKE DAMPER ASSEMBLIES, INCLUDING SLEEVES, AND INSTALLATION PROCEDURES SHALL BE APPROVED BY THE BUILDING INSPECTOR PRIOR TO INSTALLATION. 11. LABEL MEDIUM PRESSURE GAS EVERY FIVE FEET. 12. MATERIALS EXPOSED WITHIN A DUCT OR PLENUM SHALL COMPLY WITH CHAPTER 6 IMC. HVAC GENERAL NOTES 1. ALL MECHANICAL WORK TO BE PER CURRENT I.M.C. 2. ALL MATERIALS INSTALLED IN CEILING SPACE SHALL BE APPROVED FOR INSTALLATION IN A RETURN AIR PLENUM PER CHAPTER 6 OF CURRENT IMC_ 3. T e - CONSULT WITH BUILDING ENGINEER TO VERIFY FINAL CONNECTION POINT OF TEMP. CONTROL SYSTEM. (SAMPLE ZONE) 4. LOCATE THERMOSTATS AT 4' -0 (MAXIMUM) ABOVE FINISHED FLOOR 5. ALL DIFFUSER, REGISTER AND GRILLE LOCATIONS SHALL BE COORDINATED WITH ARCHITECTURAL REFLECTED CEILING PLANS, ELECTRICAL LIGHTING LAYOUTS AND SPRINKLER DRAWINGS /LAYOUTS PRIOR TO INSTALLATION. 6. ALL DUCT SIZES ARE NET INSIDE DIMENSIONS. 1. FLEXIBLE DUCTWORK SHALL BE A MAXIMUM OF 5 FEET LONG AND 514ALL HAVE A MINIMUM BEND RADIUS EQUAL TO THE DIAMETER OF THE DUCT. 8. FIRE DAMPERS: REVIEW BOTH TI-4E MECHANICAL AND ARCHITECTURAL PLANS FOR THE FIRE DAMPER REQUIREMENTS. WHERE EITHER NOTED ON DRAWINGS AND /OR AS REQUIRED BY GOVERNING CODES, FURNISH 4 INSTALL FIRE DAMPERS. FIRE DAMPERS SHALL BE INSTALLED AND BE READILY ACCESSIBLE FOR SERVICING IN THE LOCATIONS LISTED IN THE I.B.C. CHAPTER 1, 'FIRE RESISTANT MATERIALS AND CONSTRUCTION' AND SHALL BE IN ACCORDANCE WITH CURRENT I.M.C. CHAPTER 6. 9_ MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING FIELD CONDITIONS SUCH AS LOCATION 4 SIZE OF EXISTING DUCTWORK, PIPING 4 OTHER RELATED ITEMS AFFECTING CONSTRUCTION. 10. ALL CONSTRUCTION SHALL COMPLY WITH THE TENANT CONSTRUCTION STANDARDS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN TI-415 DOCUMENT FROM THE BUILDING MANAGEMENT COMPANY. 11. CONTROLS SHALL BE INSTALLED AS DESCRIBED IN THE TENANT CONSTRUCTION STANDARDS AND AS DETAILED ON THE BUILDING SHELL MECHANICAL PLANS. 12. THE CONTRACTOR SHALL FIELD VERIFY ALL P.0_C.'S AND SITE CONDITIONS PRIOR TO STARTING WORK ANY CONFLICTS WITH THE HVAC DESIGN SHALL BE COMMUNICATED TO THE BUILDING MANAGEMENT COMPANY, OWNER, AND JAMES MANN 4 ASSOCIATES IMMEDIATELY. ADDITION MALL NOTES I. ALL MECHANICAL WORK TO BE PER THE CURRENT MEP TENANT CRITERIA. 2. TESTING AND COMMISSIONING SHALL BE PROVIDED BY THE MALLS CONTRACTOR AT THE EXPENSE OF THE TENANT HVAC CONTRACTOR 3. HVAC CONTRACTOR SHALL COMPLY WITH 114E MALL'S 'TEMPERATURE CONTROLS (vAv) BULLETIN' DATED 9/22/09. 4. HVAC CONTRACTOR SHALL COMPLY WITH THE MALL'S 'MSC BULLETIN' DATED 05/09 REGARDING RELOCATING EXISTING DIFFUSER SERVING THE MALL AREAS. DX FAN COIL UNIT SCHEDULE (HEAT PUMPI SYMBOL ABBR. DESCRIPTION MAXIMUM LENGTH (FT) REMARKS SA AM v 150 TYPE HORIZONTAL RETURN AIR, CHANGE IN ELEVATION (UP OR DOWN) SENS. CLG (MBH) 58.4 CFM SA 2300 K HEATING MBH OROUND CFM OA 420 :: (I1.0) CD /SR EXT 5P .80 HSPF (COP) RG/TG RETURN GRILLE / TRANSFER GRILLE SENS GLG (MBH) 58.4 MIN. GKT. AMPS EWER EXHAUST GRILLE / EXHAUST REGISTER TOT GLcS (MDH) 641.1 0 MOCP - - ROUND SUPPLY AIR DIFFUSER TOT HTG (MBH) 35.1 FIRE DAMPER VOLTAGE 208/3/60 VOLTAGE 208/3/60 COMBINATION SMOKE/FIRE DAMPER i MVD MANUAL VOLUME DAMPER BLOWER HP 2.4 P.O.C. POINT OF CONNECTION CARRIER FAN RPM 7q7 -.It. MODEL NEW DUCTWORK - FLEXIBLE ® MAX FUSE AMPS 40 ® ' SD MIN. CKT. AMPS 36.6 EQUIPMENT SYMBOL WEIGHT (LBS) 400 U, MANUFACTURER CARRIER > -CD- cp CONDENSATE DRAIN PIPING MODEL 40RUQ001 EXISTING i / / //4 EXISTING, TO BE REMOVED SUPPLEMENTAL ELECTRIC HEAT 10 KW SHUT -OFF VALVE DI4 LSD - I PROVIDE: I. MOUNT WITH SPRING ISOLATORS, SEE #3 ON SHEET M -3 2. TXV REFRIGERANT CONTROL 3. CONDENSATE DRAIN SECONDARY OVERFLOW PAN MOUNTED BELOW UNIT. 4. FULLY MODULATING AIR5IDE ECONOMIZER AND CONTROLS. 5. SINGLE POINT POWER CONNECTION FOR FAN COIL UNIT AND ELECTRIC STRIP EMERGENCY HEATER. FAN SCHEDULE SYMBOL ABBR. DESCRIPTION MAXIMUM LENGTH (FT) REMARKS SA AM W 150 TYPE CEILING RETURN AIR, CHANGE IN ELEVATION (UP OR DOWN) SENS. CLG (MBH) 58.4 SYSTEM REST ROOM K HEATING MBH OROUND GFM 80 :: (I1.0) CD /SR SP( ") .375 HSPF (COP) RG/TG RETURN GRILLE / TRANSFER GRILLE HP 100 WATTS MIN. GKT. AMPS EWER EXHAUST GRILLE / EXHAUST REGISTER VOLTAGE 120/1/60 0 MOCP - - ROUND SUPPLY AIR DIFFUSER RPM 1000 FIRE DAMPER VOLTAGE 208/3/60 50NE5 2.2 COMBINATION SMOKE/FIRE DAMPER i MVD MANUAL VOLUME DAMPER WT (LBS) 20 P.O.C. POINT OF CONNECTION CARRIER MANUF. GOOK -.It. MODEL NEW DUCTWORK - FLEXIBLE ® MODEL GC-142 ® ' SD REMARKS #1, #2 EQUIPMENT SYMBOL I. PROVIDE BAGKDRAFT DAMPER. 2. WIRED TO RUN WITH LIGHT SWITCH. FAN PROVIDED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR. 3. PROVIDE WALL MOUNTED VARIABLE SPEED SWITCH. WIRED BY ELECTRICAL CONTRACTOR. 4. WIRED TO RUN CONTINUOUSLY. 5. PROVIDE WALL MOUNTED ON /OFF SWITCH MARKED FOR "VEHICLE EXHAUST FAN ". WIRED BY ELECT. CONTRACTOR. 6. PROVIDE UPBLAST FAN WITH VERTICAL EXTENSION OUTLET AND DRAIN. 1. WIRED TO LINE VOLTAGE T -STAT SET TO COME ON AT 85 DEGEES. WIRED BY ELECTRICAL CONTRACTOR. LEGEND SYMBOL ABBR. DESCRIPTION MAXIMUM LENGTH (FT) REMARKS SA SUPPLY AIR, CHANGE IN ELEVATION (UP OR DOWN) _ 150 #1, *2 RA RETURN AIR, CHANGE IN ELEVATION (UP OR DOWN) SENS. CLG (MBH) 58.4 , EX EXHAUST AIR, CHANGE IN ELEVATION (UP OR DOWN) K HEATING MBH OROUND DUCT, CHANGE IN ELEVATION (UP OR DOWN) :: (I1.0) CD /SR CEILING DIFFUSER / SUPPLY REGISTER HSPF (COP) RG/TG RETURN GRILLE / TRANSFER GRILLE Ar MIN. GKT. AMPS EWER EXHAUST GRILLE / EXHAUST REGISTER 0 MOCP - - ROUND SUPPLY AIR DIFFUSER T FD FIRE DAMPER VOLTAGE 208/3/60 -D SFD COMBINATION SMOKE/FIRE DAMPER WEIGHT LBS. MVD MANUAL VOLUME DAMPER 19 P.O.C. POINT OF CONNECTION CARRIER NEW DUCTWORK - RIGID -.It. MODEL NEW DUCTWORK - FLEXIBLE ® T ROOM THERMOSTAT (SUBSCRIPT = ZONE NUMBER) ® ' SD SMOKE DETECTOR EQUIPMENT SYMBOL U, UC 1' UNDERCUT DOOR > -CD- cp CONDENSATE DRAIN PIPING - - - - -- EXISTING i / / //4 EXISTING, TO BE REMOVED SOV SHUT -OFF VALVE DI4 LSD - I LINEAR SUPPLY D IFFUSER ® LRD -1 LINEAR RETURN DIFFUSER SPLIT SYSTEM HEAT PUMP SCHEDULE SYMBOL KHP) VAPOR LINE SIZE (IN) MAXIMUM LENGTH (FT) REMARKS 6 TOTAL CLG (MBH) 61.q 150 #1, *2 SENS. CLG (MBH) 58.4 HEATING MBH 35.1 SEER (EER) (I1.0) HSPF (COP) (3.3) MIN. GKT. AMPS 26.8 MOCP 45 VOLTAGE 208/3/60 WEIGHT LBS. 515 MANUFACTURER CARRIER MODEL 38AUQ001 PROVIDE: I. MOUNT ON EXISTING ROOF PLATFORM. REMOVE EXISTING OUTDOOR UNIT CURRENTLY SERVING THIS SPACE 2. AUTOMATIC. CHANGEOVER PROGRAMABLE THERMOSTAT 3. U5E TXV REFRIGERANT CONTROL. 4. FACTORY "THERMOGUARD" COATING ON OUTDOOR COIL (10 YEAR GUARANTEE) REFRIGERANT PIPING SCHEDULE SYSTEM TONS LIQUID LINE SIZE (IN) VAPOR LINE SIZE (IN) MAXIMUM LENGTH (FT) REMARKS 6 3/8" 1/8" 150 #1, *2 PROVIDE: I. SUBMIT ROUGH PIPING SCHEMATIC SKETCH SHOWING TOTAL PIPING LIFT AND LENGTH TO MANUFACTURER FOR FINAL APPROVAL OF PIPING SIZING. 2. ROUTE NEW PIPING ALONG SAME PATH AS EXISTING PIPING SERVING REMOVED UNIT. REMOVE OLD PIPING DURING DEMOLITION OF EXISTING UNIT SERVING THI5 SPACE PREVIOUSLY. FILE copy Permit No., tAl2"- 2i■ rrview approval is subject to errors and ornIssim , of construction documents does not a1. the t r, . U ort off ' • :� gf.g ion r ordinance. Receipt of L prov By Date: City Of Ttikwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: ❑ Me hanical grelectrlcal Combing QOM PIPina City of Tukwila Bu LDIN0 DIVISION REVISIONS No changes shall be made to the of work without prior approve! of T Uk 4!il3 Building Division, wtlr: t -,Alolorz will require a new pun eulxnitte1 cad may inciude add1tionat plan review fell, REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2012��Q •A v wry City of Tukwila BUILDING DIVISION Rt�trl v► CITY OF TUy TA JAN 2;5 2012 PERMIT CENTER 12 -012 space planning + interior design j studio 5580 Warbler Way La jolla, California 92037 ph: 619.9777152 fx: 858,456.0605 e: jjorgo @san.rr.com JMA JAMES MANN & ASSOCIATES MECHANICAL - PLUMBING CONSULTING ENGINEERS 11413 PINEHURST DRIVE, SUITE 100 LAKESIDE, CA 92040 819 581 -9950 FAX 819 581 -9940 (/) w z J z 0 z C\1 CT) W U a ry9 CL W Q � 017) 0 r O ; w Hwzz Q J W "er) Id < 0 < Lim 2 z o uj J W W Z 00 Q UJC\J w 0 (/) D z 0 (/) MARK DATE DESCRIPTION 12.16.11 PLAN CHECK SUBMITTAL PROJECT NO: 11145 CAD DWG FILE: DRAWN BY: JWM CHK'D BY: COPYRIGHT: SHEET TITLE HVAC - LEGEND, NOTES & SCHEDULES SHEET M -1 OF ON ROOF SERVICE CORRIDOR VERIFY FINAL LOCATION ON ROOF WITH MALL STAFF E 315 CFM 1210 L —7"." 18'd� v 7 L5D -1 180 CFM 22k ) 18'+ 8'$ Q LSD -2 100 CFM MANAGER 100-J 4 TYPICAL I8'4 1• 1A"J. 14". (100-G) ADVISOR #3 525 CFM RA (TYP OF 2) z ADJ. TENANT � 100-E J ADVISOR #1 190 CFM 8'4+ 14'0 n LSD -1 O 160 CFM 12'4' c 1 oo -o ) COFFEE /PRINT 12'. C i oae ) MEDIA BAR AL (100-M) RR 130 CFM RA LRD -1 100 CFM RA 9'. X 9'0 260 CFM (100-K ) CONFERENCE C 1001 ) STORAGE X 265 CFM 16'. 8'. X 190 CFM ADVISOR #4 (100-H) PARTIAL FIRST FLOOR PLAN ADVISOR #2 100 -F ADJ. TENANT 1'+ LSD -2 C1 oo -C) 120 CFM LOUNGE 9 ". FR (,00 -n) RECEPTION O 230 CFM 230 CFM SCALE: I/4 " =1' -0" O SHEET NOTES NEW LAY -IN CEILING DIFFUSER (TYPICAL) 02 FOR HANGING DETAILS, SEE 03 SMOKE DETECTOR IN_ -^FAIR DUCT DROP WIRED TO SHUT DOWN UNIT. VERIFY COMPATIBILITY AND CONNECTION INTERLOCK WITH EXISTING FIRE ALARM CONTROL PANEL ® NEW THERMOSTAT (MATCH MALL STANDARD). VERIFY FINAL LOCATION WITH ARCHITECT PRIOR TO INSTALLATION 05 COORDINATE MAIN DUCT TRUNK ROUTING WITH CEILING, LIGHTS, AND OTHER OBSTACLES (TYPICAL) ® ROUTE NEW REFRIGERANT PIPING SAME PATH AS EXISTING TO BE REMOVED. SEE PIPE SIZE SCHEDULE ON 11-1 0 LSD -1 = TITUS MODEL ML -39 LINEAR DIFFUSER, (2) 1' SLOT, 4' LONG WITH INSULATED PLENUM ® LSD -2 = TITUS MODEL ML -39 LINEAR DIFFUSER, (1) 1' SLOT, 4' LONG WITH INSULATED PLENUM 09 LRD -1 = TITUS MODEL MLR -39 LINEAR RETURN DIFFUSER, (2) 1' SLOT, 4' LONG WITH INSULATED PLENUM 6'. FROM EF -11 UP THROUGH ROOF WITH GOOSENECK AND BIRDSCREEN 11 20X20 OUTSIDE AIR DUCT FROM ECONOMIZER ON FC -I UP THROUGH ROOF WITH GOOSENECK AND BIRDSCREEN 12 REMOVE EXISTING HEAT PUMP ON ROOF CURRENTLY SERVING THIS SPACE. INSTALL NEW HP -I IN SAME LOCATION CD MALL Mir REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2012 City of Tukwila BUILDING DIVISION CITY OF TUKWLA SAN 2;5 2012 ERMIT CENTER space planning + interior design j studio 5580 Warbler Way La jolla, California 92037 ph: 619.977.7152 fx: 858.456.0605 e: jjorgo @san.rr.com JMA JAMES MANN & ASSOCIATES MECHANICAL - PLUMBING CONSULTING ENGINEERS 11413 PINEHURST DRIVE, SUITE 100 LAKESIDE, CA 92040 819 581 -9950 FAX 619 561 -9940 >—. N N- CO 0 co (f) < %--, 00 W ctz 1 < 0, z V >7QO 0LUH ZE-EZZ < 1 D 0 _ W 2 U C Et Q OQ LL D ZwwQH z O 0 z U V) jZcO< ZLLJC\JLLJ 0 Z D 0 V) o ti z < '_ . G . , -,' A% S� ER MARK DATE DESCRIPTION 12.16.11 PLAN CHECK SUBMITTAL PROJECT NO: 11145 CAD DWG FILE: DRAWN BY: JWM CHK'D BY: COPYRIGHT: SHEET TITLE HVAC - PARTIAL FIRST FLOOR PLAN _2 SHEET OF SECTION 15050 BASIC MECHANICAL REQUIREMENTS PART 1 - GENERAL 1.01 SUMMARY A. Work Included: Basic mechanical requirements governing materials and workmanship incorporating heating, ventilating, air conditioning and related trades as specified herein. 1.02 REFERENCES A. Materials and workmanship shall comply with the following references, which are incorporated into the text by common abbreviation only. Supplements which have been adopted by the governing agencies shall take precedence. UPC - Uniform Plumbing Code (Current Edition) Including supplements IMG - International Mechanical Code (Current Edition) Including supplements NEC - National Electric Code (Current Edition) NFPA - National Fire Protection Association Standards (current editions) IBC - International Building Code (current edition) Including supplements Seattle Non - Residential Energy Code MEP Tenant Criteria Mall Building Standards B. HVAC System components and installation shall comply with the nationally recognized standards for the types of equipment used including, but not limited to, Underwriters' Laboratories (UL), Sheet Metal and Air Conditioning Contractors National Association (SMACNA) and the American Society of Heating, Refrigerating, and Air - Conditioning Engineers (ASHRAE) Handbook. 1.05 SUBMITTALS A. Product Data: Submit six copies of Manufacturer's data for each item to be incorporated into the work. Data shall be bound into vinyl binders of I" capacity and shall include an index at the front listing all of the contents. B. Shop Drawings: Submit shop drawings showing related dimensions, accurately scaled to established references and points of verification. Show sizes, materials, connections, elevations and related information. G. Record Drawings: Contractor shall maintain accurate "as- built" marked -up drawings throughout the construction period. Prior to final acceptance, the Contractor shall submit (1) complete reproducible as -built set of drawings, dated and signed. HVAC contractor shall also provide Autocad based files of the "As- Builts ". D. Substitutions and Product Options: No substitutions shall be allowed unless there Is prior written approval by the Architect. 1.04 PROJECT /SITE CONDITIONS A. All construction shall comply with the tenant construction standards. It shall be the Contractor's responsibility to obtain this document from the Building Management. B. The Contractor shall field verify all P.O.G.'s and site conditions prior to starting work. Any conflicts with the HVAC design shall be communicated to the Building Management immediately. G. Prior to installation of HVAC components, the Contractor shall verify that related installations and materials are complete to ensure no Interruption or Interference by delinquent trades. Notify Owner of all such delinquencies and obtain review and direction prior to proceeding, or accept responsibility for correction of faulty /defective installations. D. All valves, volume dampers, motors and any device that requires adjustment or servicing shall not be located in an inaccessible location. These devices shall be located adjacent to lay -In ceilings or be provided with access panels if required to be installed over drywall ceilings or shafts. E. Permits and Fees: This Contractor shall arrange, apply for and pay for all permits, inspections, fees, and licenses required for this work by any legally constituted public authority. This Contractor shall furnish the Owner with final certificate of inspection at the completion of the work. F. Gleaning of Equipment and Premises: This Contractor shall thoroughly clean all equipment and apparatus and leave in satisfactory condition for finish painting. If equipment has been supplied with the factory finish, the Contractor shall also be responsible for touch -up work and /or refinishing if required. During construction of the job, this Contractor shall be responsible for clean up of cartons, scrap or debris caused by this work. 1.05 SEQUENCING AND SCHEDULING A. Contractor shall be responsible for scheduling the work of related trades to ensure timely and orderly progress of the total work to be performed. 1.06 GUARANTEES A. New materials and equipment to be guaranteed free from defects and faulty workmanship fora minimum period of one year from date of occupancy. PART 2 - PRODUCTS See Section 15500 and drawings. PART 5 - EXECUTION See Section 15800 and drawings. END OF SECTION SECTION 15800 HEATING, VENTILATING, AND AIR CONDITIONING PART 1 - GENERAL 1.01 SCOPE A. The basic mechanical requirements apply to work under this section. Furnish all materials and labor required to execute this work as indicated on the drawings, specified herein and necessary to complete the contract, including, but not limited to, the following principle items: 1. Scheduling and sequencing. 2. Ductwork and accessories. 5. Air distribution, registers and grilles. 4. Submittals. 5. Coordinate with other disciplines. (Le. electrical, plumbing, and fire protection) 6. Acoustical and thermal insulation. 7. Noise and vibration isolation. 8. Controls. 1. Permits, fees, inspections and certificates for work included under this section. 10. Test and balance. PART 2 - PRODUCTS 2.01 DUCTWORK AND ACCESSORIES A. Ductwork for air conditioning, heating, ventilating and exhaust system shall be fabricated of galvanized sheet steel. I Volume dampers shall be manually operated as indicated on the drawings, shall be two (2) gauges heavier than the duct In which it is installed, and shall be equipped with locking quadrants. All dampers shall be marked with bright colored ribbon for easy identification. 2. Sheet metal duct seams (transverse) shall be made air -tight with an approved high pressure duct sealing compound (Duro- Dyne S2). Longitudinal seams on duct systems with internal static pressures 0.15 in. water or greater shall be sealed as described above. Longitudinal seams shall be Pittsburgh Lock. 5. All ductwork fabrication and installation shall be in accordance with all applicable codes and standards. 2.02 FLEXIBLE DUCT A. Insulated low pressure flexible duct shall be a factory fabricated assembly consisting of a zinc - coated spring steel helix, with 1 inch thick fiberglass insulation, sheathed in a seamless vapor barrier jacket. The interior of the duct shall have a fire resistive coating to prevent fiber erosion. The duct shall have a straight run sound absorption of 5 decibels per foot and 5 decibels per foot of 45 degree bend. The composite assembly, including insulation and vapor barrier, shall meet the Class 1 requirements and shall have a flame spread of 25 or less and a smoke density of 50 or less as set forth in NFPA Standard No. c1O -A and be labeled by Underwriters' Laboratories, Inc. as an air duct. B. Flexible duct shall be installed in a fully extended condition free of sags and kinks, using only the minimum length required. Flexible duct shall be suspended on 56 inch centers with a minimum 5/4 Inch wide flat banding material. G. Insulated low pressure flexible duct shall be type 5 -I5I as manufactured by Glass Insulation Company, Inc. Los Angeles, California, or approved equal. D. Flexible duct shall be city and state approved and shall be 5' -O" maximum in length as manufactured with metal joint collars on both ends. Flex duct cutting is not allowed. E. High pressure flexible duct shall be some as above except approved for use up to 4" static pressure. 2.05 INSULATION A. All work and material installation shall be performed in accordance with the published recommendations of the manufacturer, and the local codes workmanship shall comply with the best practices of the trade. 1. All materials must conform to the requirements of NFPA ci0A as determined by The Underwriters' Laboratories method, NFPA No. 255 and ASTM E84, and shall conform with the governing code. Flame spread shall be 25 or less and smoke - density shall be 50 or less. 2. Where vapor barriers are used, they must be intact and continuous throughout. All seams, joints and punctures shall be sealed watertight. 5. Approved manufacturers: Owens - Corning Fiberglass, Johns - Manville, PPG, Gertainteed. B. Concealed Ducts: All supply air ductwork shall be insulated with 1 -1/2 inch thick, 5/4 pound fiberglass duct wrap, Johns Manville, Owens - Corning, PPG or CSG, in accordance with California Title 24 Energy Requirements (with vapor barrier). Insulation shall be firmly wrapped around ductwork covering all surfaces, Including standing seams, and with all joints lapped a minimum of 2 ". Insulation shall be securely fastened in place with 16 gauge soft annealed black or galvanized wire spaced approximately 12" on centers for straight runs, and 5" centers for elbows and fittings. G. Acoustical Duct Liner: Fan coil plenums, return air plenums and transfer air ductwork shall be lined with coated J -M 1.5 PGF Microtex coated duct liner. Duct Liner shall be a minimum of I" thick. Duct liner material shall be applied with coated side facing air stream and secured to sheet metal using adhesive and fastened mechanical clips spaced as recommended by the manufacturer. All joints shall be tightly butted and heavily sized with Lagfas or Arabol adhesive to assure the continuity of the surface. Duct sizes shown are net clear dimensions. Increase duct size to allow for duct liner. 2.04 AIR OUTLETS A. All grilles, registers, diffusers and other air outlets shall be furnished, installed and carefully located with respect to lighting fixtures. Ceiling outlet locations shall be as approved by the Architect. B. All duct or plenum interior surfaces visible through grilles from any vantage point, in occupied space, shall be painted black. G. Air distribution shall be "Titus" or approved equal. LAY -IN TYPE CEILING Gelling Diffuser: Model PCS or PCS -DF, frame to match ceiling type. Return/Exhaust Registers: Model PAR or PDR, frame to match ceiling type. DRYWALL TYPE CEILING Ceiling Diffuser: Model 500FS, frame to match ceiling type. Return/Exhaust Registers: Model 55OFL, frame to match ceiling type. 2.05 FIRE DAMPERS A. Verify and include all fire dampers required by fire rated walls and ceilings. Fire dampers shall be approved and listed by the State Fire Marshal as manufactured by "Ruskin ", or equal, as follows: 1. All shall be per U.L. 555 or U.L. 555S. 2. All shall be rated according to the rating of the penetration (i.e. 1 -1/2 or 5 hour ratings). 5. Dampers shall be with blades outside of air stream. 4. Provide combination smoke /fire dampers where indicated on drawings. 2.06 SYSTEM CONTROLS A. System controls shall match existing onsite. Match owner base system for this property. B. New thermostats, shall be coordinated with mall's control contractor.. PART 5 - EXECUTION 5.01 BALANCING, TESTS, AND GUARANTEE A. Total system balance shall be performed by an independent, non- affiliated agency certified by the Associated Air Balance Council (AABG) which specializes in and whose business is dedicated to testing, adjusting and verification of the HVAC system performance. The submittal of unbiased reports shall be timely upon completion of work. This work shall conform to AABG specifications referred to in Chapters 11 through 26 of the AABG National Standard and other criteria as set forth in this specification. B. Balancing Contractor shall balance the air conditioning, heating and ventilating systems so that proper air and water flow is demonstrated at each unit (SA register, heat pump, etc.). Three (5) balance reports shall be submitted to Architect. G. System shall be tested for a minimum of 8 hours for proper operation and all defects shall be remedied in a manner acceptable to the Architect. For a period of 50 days after completion, the Contractor shall provide the service of a technician to spot check and adjust air balance if requested by the Building Management. D. At the conclusion of tests, and after the acceptance by the Engineer, system shall be turned over to Owner and a guarantee period of one (1) year will commence. This guarantee will cover all equipment installed under this contract and, during the guarantee period, all defects shall be remedied without cost to the Owner. A knowledgeable representative of the Contractor shall, at the time of turnover, instruct the designated representative of the Owner in the proper operation and maintenance and shall supply him with three copies of all maintenance and operating instructions of the installed equipment neatly bound in three separate folders. END OF SECTION DO NOT SUPPORT FROM DECK (NO SHOOTING INTO DECK) CONNECT TO STRUCTURE OR PROVIDE SECONDARY SUPPORT 45 DEG. PROVIDE 12 GA. VERTICAL WIRE PER UBC STD 25213 AND 25214-1•• (AT OPPOSING CORNERS) SECURE TO STRUC- TURE ABOVE ACCOUSTICAL FLEX DUCT - 1' LENGTH CEILING - VOLUME DAMPER (MARK w/BRIGHT COLORED RIBBON) ROUND DIFFUSER NECK - SIZE AS INDICATED ON PLAN (BY SIZE OF BRANCH DUCT) 24'x 24' LAY-1N TYPE CEILING DIFFUSER RETURN AIR CEILING DIFFUSER NO SCALE BRANCH DUCT 45 DEGREE ANGLE MAIN RECTANGULAR BRANCH DUCT BRANCH FLEX OF SPIRAL DUCT MANUAL VOLUME DAMPER ON FITTINGS 45 DEGREE ANGLE MAIN ROUND BRANCH DUCT TYPICAL BRANCH DUCT NO SCALE DO NOT SUPPORT FROM DECK (NO SHOOTING INTO DECK) CONNECT TO STRUCTURE OR PROVIDE SECONDARY SUPPORT 45 DEG. PROVIDE 12 GA. VERTICAL WIRE PER UBC STD 25213 AND 25214 OPPOSING CORNERS) CEILING SECURE TO STRUC- TURE ABOVE ACCOUSTICAL FLEX DUCT - MAX. LENGTH = VOLUME DAMPER (MARK wBRIGHT COLORED RIBBON) ROUND DIFFUSER NECK - SIZE AS INDICATED ON PLAN (BY SIZE OF BRANCH DUCT) 24'x 24' LAY -IN TYPE CEILING DIFFUSER SUPPLY AIR CEILING DIFFUSER NO 5CALE SUPPORT STRUCTURE, FOR ATTACHMENT SEE STRUCTURAL DRAWINGS MASON TYPE SCB (OPA -0349) REF. PAGE XI 2 MASON TYPE 30N ISOLATION HANGER W/ REBOUND WASHER MASON TYPE UC (OPA -0349) REP. PAGE X5A GALVANIZED DRIP PAN UNDER FC -I UNIT ALL THREAD ROD ROD STIFFENING STRUT MASON TYPE SCi314 (OPA -0349) REF. PAGE X2 NOTE: SEE 'MASON' 14ANDBOOK FOR SPECIFIC ELEMENTS REQUIRED FOR EACH UNIT TYPE. FAN COIL UNIT SUPPORT (FC-1) STEEL AIRCRAFT CABLE, 1 X 19 STRAND CORE REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2012 City of Tukwila BUILDING DIVISION NO SCALE REGtilvti CITY OF TUK1MLA JAN 252012 PERMIT CENTER space planning + interior design j studio 5580 Warbler Way La jolla, California 92037 ph: 619.977.7152 fx: 858.456.0605 e: jjorgo @san.rr.com JMA JAMES MANN & ASSOCIATES MECHANICAL - PLUMBING CONSULTING ENGINEERS 11413 PINEHURST DRIVE, SUITE 100 LAKESIDE, CA 92040 819 581 -9950 FAX 819 581 -9940 (I) w �z WId >z ZH Jo <u- z zw 0Z I-- z N (7) W U < CO CL cn J � 07) I Q 67 111- Z w w > F. w Z Z 1 J w J = Q> O w% Lil H � � J ZcO< UN z u) 0 MARK DATE DESCRIPTION 2.16.11 PLAN CHECK SUBMITTAL PROJECT NO: 11145 CAD DWG FILE: DRAWN BY: JWM CHK'D BY: COPYRIGHT: SHEET TITLE HVAC - DETAILS & SPECIFICATIONS SHEET M -3 OF