MECHANICAL PERMIT
Project Name: REIT MANAGEMENT & RESEARCH
Permit Number: M12 -020
Issue Date: 03/01/2012
Permit Expires On: 08/28/2012
Owner:
Name: BLUE DOG PROPERTIES TRUST
Address: THOMSON REUTERS TRUST , 2235 FARADAY AVE SUITE 0 92008
Contact Person:
Name: BUD WARE
Address: 109 WASHINGTON BL STE B , ALGONA WA 98001
Email: BUDW @FIVESTARMECH.COM
Contractor:
Name: FIVE STAR MECHANICAL
Address: 109 WASHINGTON BLVD STE B , ALGONA WA 98001
Contractor License No: FIVESM *010JT
Phone: 253- 852 -8284
Phone: 253- 852 -8284
Expiration Date: 04/30/2012
DESCRIPTION OF WORK:
REMOVE & REPLACE (2) EXISTING HEAT PUMPS - 6 TON AND 4 TON
Value of Mechanical: $20,000.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
(JaR-
Fees Collected:
$428.56
International Mechanical Code Edition: 2009
Date: '‘"?•—• 12
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Signature:
Print Name:
e r�
2C) 4/ p'z' 7-7
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M12-020 Printed: 03 -01 -2012
PERMIT CONDITIONS
Permit No. M12-020
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Readily accessible access to roof mounted equipment is required.
7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
8: Manufacturers installation instructions shall be available on the job site at the time of inspection.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
12: ** *FIRE DEPARTMENT CONDITIONS * **
13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned
in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051)
15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
air- moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051)
17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051)
18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051)
19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
doc: IMC -4/10
M12-020 Printed: 03 -01 -2012
project.
21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
doc: IMC -4/10
M12 -020 Printed: 03 -01 -2012
• •
CITY OF TUKWILA
Community Development Departn►ent
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http : / /www.TukwilaWA.gov
Mechanical Permit No. _____Nic>2_Org..
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *please print **
SITE LOCATION
/ y ) fl King Co Assessor's Tax No.:
Site Address: d /7 .F /idgs lity A r iue. 7 Jell
Tenant Name: �J
PROPERTY OWNER
Name: Q
Re i+ /11441 e,Ylort 4_ 1■ e SeGrc_i)
1
4 /7 e ssIn Qc frii. f$sft itie
City: p
.T� 1c_wi /a . /115 efifa i
CONTACT PERSON — person receiving all project
communication
Name: Q1 0 wGrc°
iD q ePica shh 0 ibn OW S4e a
CV. ,cf 1 oh 0. • State,; ,, Zip 1god_
Phone: DI 5?— lib 2-Ti t Fax: 253 -vs a.- g -i. O S
Email:
& d ii .P iUP Star A' ° c_h, cowl
Suite Number: Floor:
New Tenant: ❑ Yes ❑ .. No
MECHANICAL CONTRACTOR INFORMATION
Company Name: Ft jc 6kr .Jr.eactri i C4'
Ad ess:
/O . waghr lq,on $ Iua 54 3
City:d-r State :W A Zie e,oi
lgsh‘ '1
Phone:a — —I ca b _ Faxb. ate , $ 6- 72-1 Co
Contr Reg No.: F zvE s ml 94 Exp Dptee .5 T
(�
Tukwila Business License No.:
Valuation of project (contractor's bid price): $ `�V Opp
Describe the scope of work in detail:
Remove 4- 12ep k e
\ec pLA- v'h.ps a % -ov Curia a 1-t tovk
Use: Residential: New
Commercial: New
Fuel Type: Electric Gas
Replacement
Replacement
Iss
Other:
H:\ ppltcations \Form- Applications On Lme\2011 Apphcanons\Mechanical Pemut Application Revised 8- 9- 11,docx
Revised: August 2011
bh
Page 1 of 2
z
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall /floor
mounted heater
Appliance vent
Repair or addition to
heatlrefrig /cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial.
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler /Compressor
QtY
0 -3 hp /100,000 btu
3 -15 hp /500,000 btu
15 -30 hp /1,000,000 btu
30 -50 hp /1,750,000 btu
50+ hp /1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 0 NER AUT ZED � NT:
Signature: /sp
Date:
2- .2'1� --
Print Name: 6-c r q 1.4 L. Q l-e r• Day Telephone:
Mailing Address:b 5 W qgl-,; n� Nuek S } e 3 IAAl t31r1 c_ tL) A q $
City State Zip
H:\ Applications \Forms- Applications On Line\2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx
Revised: August 2011
bh
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.TukwilaWA.uv
RECEIPT
ParcelNo.: 2523049008 Permit Number: M12 -020
Address: 617 INDUSTRY DR TUKW Status: APPROVED
Suite No: Applied Date: 02/09/2012
Applicant: REIT MANAGEMENT & RESEARCH Issue Date:
Receipt No.: R12 -00882
Payment Amount: $342.85
Initials: WER Payment Date: 03/01/2012 03:38 PM
User ID: 1655 Balance: $0.00
Payee: FIVE STAR MECHANICAL
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 37518 342.85
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
MECHANICAL - NONRES
000.322.102.00.00 342.85
Total: $342.85
doc: Receipt -06 Printed: 03 -01 -2012
City of Tukwila
Departinent of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
Parcel No.: Permit Number: M12-020
Address: 617 INDUSTRY DR TUKW Status: PENDING
Suite No: Applied Date: 02/09/2012
Applicant: REIT MANAGEMENT & RESEARCH Issue Date:
Receipt No.: R12 -00579
Initials: TLS
User ID: 1670
Payment Amount: $85.71
Payment Date: 02/09/2012 01:12 PM
Balance: $342.85
Payee: GERALD WARE WARE ENTERPRISES INC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 51902G
ACCOUNT ITEM LIST:
Description
85.71
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 85.71
Total: $85.71
doc: Receiot -06 Printed: 02 -09 -2012
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
E
SEPARATE PERMIT
IT
REQUIRED FOR:
❑ Mechanical
'Qt Electrical
Plumbing
Gas Piping
City of Tukwila
BU j...DiNG DIVISION
r New
1-14-on
GS/
Feu)
•
2b
rnd s4-ry ) 'ive (A1C 101) 1)3J 9 %o01_
T3 Lti( cit 2-1
FILE COPY
Penult No.. pq Z- '—n` ,
Phan review approval is subject to errors and OrtiSE401111.
Approval of construction documents dons not authorize
tit. violation of any adopted code or ordinance. Receipt
of approved Reid yand .edged:
By •fr
Dar
3f 1 -l2
City Of Tukwila
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 2 3 2012
City=�.�.
of u ila
BUILDING VISION RECEIVED
FEB 09 2012
?ERMITCENTER
1.1-4- 020
James W. Ashley -Cole, P.E.
CONSULTING ENGINEER
CALCULATION SUBMITTAL
For
Five Star Mechanical.
FILE COPY
Permfl Mo.
HVAC Up -Grade
617 Industry Drive
- • Building]
Tukwilla WA
IA I Xler 010
Project No. 2012.06
February 1, 2012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 2 3 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
FEB 09 2012
PERMITGENTER
Extent of Analysis; The structural details, general notes, and sealed engineering calculations included
with this submittal have been prepared exclusively for the above referenced project. This submittal has
been limited to the design of the HVAC gravity support and seismic anchorage. No other aspect of the
existing structure has been addressed by this submittal.
• The condition of the roof was observed to be in good condition. In my opinion the roof is suitable for
the support of the proposed replacement units.
• All flashings, coatings, membranes and sealants are by others.
Design Criteria:
Actual Equipment Weights:
Roof: 25 PSF
Seismic: Sds( Seismic Design Category D) = 0.8334, Rp = 2.5
Wind: 85 MPH, Exposure B
525 Columbia Street NW, Suite 201 Olympia WA 9850i t. 360.70
STRUCTURAL NOTES
These structural notes apply to all structural components of the primary structural systems. Any
discrepancies found among the drawings, these notes and the site conditions shall be reported to the
Engineer of Record, who shall correct such discrepancy in waiting. Any work done by the Contractor after
discovery of such discrepancy, but prior to correction of such discrepancy, shall be done at the
Contractor's risk.
• The Contractor shall field locate and identify all site utilities prior to performing any site excavation or
demolition. The Contractor shall be responsible for all safety precautions and methods, techniques,
sequences or procedures required to perform the Contractor's work The Consulting Engineer has no
overall supervisory authority or actual and/or direct responsibility for the specific working conditions
at the site and/or for any hazards resulting from the actions of any trade contractor. The Consulting
Engineer has no duty to inspect, supervise, note, correct, or report any health or safety deficiencies to
the Owner, Contractor, or other entities or persons at the project site.
• All structural systems which are to be composed of components to be field erected shall be supervised
by the supplier during manufacturing, delivery, handling, storage and erection in accordance with the
written instructions prepared by the supplier.
• It is the Contractor's responsibility to verify all field measurements and site conditions prior to
fabrication of any structural elements. No allowance will be made for any items incorrectly fabricated
or installed due to failure to perform such verification prior to commencing work. Contractor initiated
changes shall be submitted to the Consulting Engineer in writing for approval prior to fabrication,
construction or field modification. Changes shown on shop drawings only will not satisfy this
requirement.
• Non - structural building systems, including: fire resistive assemblies, ADA accessibility, thermal or
moisture protection, furnishings, doors, equipment, mechanical, electrical, finishes, siding, paneling
veneers, paints and coatings are not the responsibility of the Consulting Engineer.
CONSTRUCTION STABILITY
The design, adequacy and safety of erection bracing, shoring and all temporary supports is the sole
responsibility of the Contractor, and has not been considered by the Engineer of Record. The Contractor
shall provide the bracing necessary to provide stability to the structure prior to the completed application
of the lateral system. During construction the Contractor shall keep loads within the design roof and floor
loads limits shown on the drawings.
CODES AND DESIGN
All methods, materials and workmanship shall conform to the 2009 edition of the International Building
Code (IBC) as amended and adopted by the local Building Department. All reference to other codes and
standards, such as ACI, ASTM, AISC, etc. shall be for the latest or most current edition available.
DESIGN LIVE LOADS
Roof: 25 PSF
Seismic: Sds( Seismic Design Category D) = 0.8334, Rp = 2.5
Wind: 85 MPH, Exposure B
WOOD FRAMING AND LUMBER GRADING
Allowable stress required shall be in accordance with standard grading rules of West Coast Lumber No.
16. Moisture content shall be maximum 19%. All studs, plates and blocking at shear walls, load bearing
and exterior studs and plates shall be of grade Douglas-fir #2 or better, unless noted otherwise. Structural
Panel Sheathing including Plywood and Oriented Strand Board (OSB) sheathing shall be APA grade
trademark sheathing with nominal thickness as indicated on the contract drawings. All glue -lam beams
shall be 24F -V4 UNTO as 24F -V8 at cantilever conditions.
Wood framing details, not shown otherwise, shall be constructed to the minimum standards of the 2009
IBC and shall conform to the Fastening Schedule 2304.9.1. Unless noted otherwise, all nailing callouts
refer to common type nails.
Notations on drawings relating to framing clips, joist hangers and other connectors refer to catalog
numbers manufactured by the Simpson Strong Tie Company, San Leandro, CA, Catalog C -2012. All
hangers in contact with preservative treated lumber shall be "Z -MAX" galvanized with approved fasteners
as noted.
SECTIONS AND DETAILS
Sections and details showing reinforcing, bolts, framing members, and connections are intended to
illustrate specific detail. No attempt has been made to show all elements passing through a specific section
or detail. Exposed bolted beam connections may have to be furred by the Contractor to conceal connector.
Construction details not specifically shown on the drawings shall follow similar details or sections of this
project as approved by the Engineer.
SPECIAL INSPECTION
An independent third party Special Inspector shall be retained by the Owner for the following:
• Any item required by the Building Official.
CONSTRUCTION OBSERVATION
The Contractor shall notify the Engineer of Record for observation of The following:
• Any item required by the Building Official.
ON$ULT NG ENGINEER
z+
- 1.(#-/".6.
-.0
1W
4
-
_
- -
7.
111N
--t.-.b7"-
--
e
---_____
.ra.
o
--
f
'gib
- -.
../.'0f;91..._
CF. -
Zi
L‘zZ
VP
-sc
-
.. --
/
ok4).
-
9p'Iz >f
1 133HS
1A1111■11Taf &I
k133NION3'JNillfl
NO
g•
`
103-
apl1sy A/
saws/'
ON UL1ING ENGINEER
e Lid Li 4-0q r�1t�f w ®lo
--- •
WO (A WA A WCC3O48A- SUB -1 E
TAG:
4 Ton Convertible Heat Pump Packaged Units
2/4WCC3048A1000A
PRODUCT SPECIFICATIONS
MODEL 2WCC3048A1000A 4WCC3040A1000A
RATED Volts/Ph/Hz 208- 230/1/60 208 - 23011/60
RATINGS (COOL) CO BTUH 46000 48
Indoor Airflow (CFM) 1600 1600
Power Input (KW) 423 4.33
EER/SEER (BTUM1att-Hr.)® 11/13 10.75/13
Sound Power Rating (dB(A))® 79 80
(High Temp.) BTOH�
Power Input (KW)
(Low Temp.) BTUH
Power Input (KW)
HSPF (BTU / Watt-Hr.) O
POWER Min. t r3 dt. Cir Ampacity W
Fuse Size —Max. (Amps)
Fuse Size — Recmd. (Amps)
46500
3.52
28200
2.95
7.70
208-230/1/60
28.6
46
46
47000
3.92
28200
3.65
7.70
208. 230/1/60
31.1
50
60
vg FSSOR
R.L. Amps --L.R. Amps
OUTDOOR COIL —TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
ReMgerant Control
INDOOR COIL —TYPE
ow .1.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (In.)
OUTDOOR PAN -- TYPE
ta. (tin.))
Drive/No. Speeds
CFM 0.0 In. w.g. O
Motor —HP / R.P.M.
. Volts/Ph/Hz
F.L. Arnps/L.R. Amps
DIaDWidihF(N —TYPE
Drive / No. Speeds
CFM v.s. IN. W.S.®
Motor —HP / R.P.M.
Volts/Ph/Hz
F.I.. Amps/L.A. Amps
Vype Recommended D7
Min. Face Area (sq. ft.)
REFRIGERANT (I
GIMEN$IONS
Crated (in.)
LIGHT
aping (lbs.) / Net (Ibs.)
Cot 2010 Tram)
200-230/1/60
18.6193.4
SPINE FIN
2/24
20.98
3/8
EXPANSION VALVE
PLATE FIN
4/15
6
3/8
EXPANSION VALVE
3/4 FEMALE,., f�PT
PROPELLER
27.6
DIRECT /1
4400
1/4/825
230/1/60
1.4/3.1
CENTRIFUGAL
1�0�xO10
SEE FAN PERF TABLE
314 /1080
200- 230/1/60
4/8.4
NO
THROWAWAY
5.3
(R -22)
726
HXWXD
49.86X47.4X61.75
200-230/1/60
20.5/109
SPINE FIN
2/24
18.01
3/8
EXPANSION VALVE
PLATE FIN
4/15
6
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
27.8
DIRECT /1
4400
1/4/825
230/1/80
1.4/3.1
CENTRIFUGAL
10 x 10
p L3
SEE FANRPpERF TABLE
3/4/1080
200-230/1/60
4/8.4
NO
THROWAWAY
5,3
(R -410A)
7.75
HXWXD
47.86X47.4X61.75
553/425
553/
CU Certified In accordance with the Unitary Air - Conditioner Equipment
certification program, which Is based on ARI Standard 210/240.
®Sound Powerval uesere not adjustedlorAR1270- 95 tonal corrections.
0 Calculated in accordance with currently prevailing Nat'l Electrical
Coda.
C) Standard Air— Dry Coil — Outdoor.
11 Standard Air — Wet Coil — Indoor.
(5 Rated In accordance with O.O.E. test procedure.
(/) t=iters must be installed In return air system. Square tooteges listed
are based on 300 f.p.m. face velocity. If permanent filters are used
size per manufacturer's recommendations with clean resistance of
0.05• W.C.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 2 3 2012
City of Tukwila
BUILDING DIVISION
11 2'o2o
RECEIVED
FEB 09 2012
PERMITCENTER
eu)
Installation
40(1
AWARNING
Heavy Objects!
Ensure that all the lifting equipment used is properly rated for the weight of the unit being
lifted. Each of the cables (chains or slings), hooks, and shackles used to lift the unit must be
capable of supporting the entire weight of the unit. Lifting cables (chains or slings) may not be
of the same length. Adjust as necessary for even unit lift. Other lifting arrangements could
cause equipment or property damage. Failure to follow instructions above or properly lift unit
could result in unit dropping and possibly crushing operator /technician which could result in
death or serious injury.
AWARNING
Improper Unit Lift!
Test lift unit approximately 24 inches to verify proper center of gravity lift point.To avoid
dropping of unit, reposition lifting point if unit is not level. Failure to properly lift unit could
result in unit dropping and possibly crushing operator /technician which could result in death
or serious injury and possible equipment or property -only damage.
Table 1. Maximum unit & comer weights (Ibs) and center of gravity dimensions (in.)
Unit
Tons Model No.
3 WSC036E
4 WSC048E
5 WSC060E
W SC072E
7'h WSC090E
10 WSC120E
tc 6Th
Maximum Model
Weights(a)
Corner Weights(b) Center of Gravity (in.)
Shipping Net A B C D Length Width
589 514 177 107 113 117 29 20
600 525 181 109 115 119 29 20
825 682 228 177 114 163 38 24
835 740 235 196 140 168 40 22
902 804 255 217 153 180 41 22
1431 1219 355 333 257 274 48 28
(a) weights are approximate.
(b) Corner weights are given for information only.
RT- SVX23E -EN
Figure 12. Comer weights
A
CENTER OF GRAVITY
-.10-- LENGTH
CENTER OF
GRAVITY
WIDTH
D
CENTER OF GRAVITY
21
General
Data
Lil-ovi
Table 2 General Data
4 TON DOWNFLOW & HORIZONTAL 01 1CA
WC0048A3 WC11049A3
WCOO48A1 WCD048A4 WC0048AW WCH048A1 WCH040A4
W CH048AW
GenoralDeto
COalinGPMOrmenCe'
0ro,sCoo1in3C0p•dty 61400 61400 60400 51400 61400 60300
A. Mt. Mel tooting Capacity 49000 49000 48000 49000 48000 98000
00816515' 8.00/10.20 9.001- 9.001- 5.00/10.20 9.00,- 0.001 -
Nominal Cho 1600 1000 1800 1800 1800 1600
9ymeln Kw 6.44 5.44 6.32 6.44 6.44 5.33
A.R.I. Sound Rndn916E181' 8.8 8.8 9.0 8.8 9.6 8.8
HatingtHeelinpl'
1140112e150.18tdt 48500 47500 48000 48600 47500 48000
51/310m Power (Kw end 0091 4.7413.00 4.49/3.10 4.08(3.00 4.74/3.00 4.49/310 4.8813.00
11.OWTamp2 Mull 20000 24000 26000 20000 54000 25000
8yatent POwar (Kw and COP) 3.89(2.00 3.69/2.00 3.07/2.00 3.89/2.00 3.5912.00 2.0712.00
HSPF(Otu/Watohr.P 7.00 - - 7.00 - -
Commute / -No.n m•
I /C6nendr 1 /Clhnatut1 11CIhmtN1' 1 /Climatal1. 11C11meIv11' 1 /CFmetuII`
Indoor Coil -Type Platt Fin Plate Fin P1614 FM Plate Fin /101, Fla Plata fin
Tube Site liU.! .30 .38 .39 .08 .38 .30
Fess Area 184. FO1 5.49 5.48 6.49 6.49 5.43 6.49
Rowe /PM 4/12 4/12 4.12 4.12 4.12 4.12
Rordgerant Cennrol Expansion Valve Eapanaton VONa Cepon/1en Valve 65501410a Viva Espemlon Volvo 6xpantlon Valve
Drain Conn. Size Yn.I 110/ PVC M "PVC %'PVC 11. PVC 16. PVC 6'PVC
Outdoor Cell-A/pa Plele Nn Plate Fin Mme Nn Plate Fin Mete Fin F1510 FM
81174 Sim lis.l 001 .30 .38 .38 .38 30 .30
Feel Mee ISO. Ft.1 14.8 19.8 14.8 19.8 14.8 14.8
HowlfFF7 2/16 2116 2(16 2/15 2118 2/15
ROfn00ran1 COntrO1 Expansion V4100 exponvon Valve Espwuto0 Valve e.oNIalea V4140 101,04104 1411V81 18Penata4 Were
1n000lpen -Type Cfinelu84( Centdru9al Can1IF5900 Centil(u541 Cenanupel Canld)ugdl
Moto, Hp .78 .78 .76 .76 .76 .76
O.ire /Speed4NO.1 O6ecs/3 Ohect /$ 01,0.119 01,0.113 01rest/3 OFrou113
No. Used 1 1 1 1 1 1
OM. xW1dhlln.) 11.0x0.5 11.0,9.5 11.8,9.8 11.0x8.6 11.0x8.5 11.0x9.5
Motor Rpm 1078 1075 1079 1075 1075 1076
Outdoor Fan -Typo Proposer Propeller Propeller P.epolar Propellor 9,494051
No. 1.1444-01o.157.1 1123 1/22 1/22 1/22 1/22 1/32
Onw,9paed INe3 01.441/1 Do401 /1 Cheat/1 Obect/I Ohe.1 /I Olreet /1
Cfm4 4900 4800 4800 4800 4800 4800
No. Motors -Hp 1 /.50 11.50 1/.50 1/.60 11.60 1 /.50
Rpm 1075 1075 1076 1076 1075 1075
Filel. - TypeIFINnlrhad1
No. /SlmReeemmandad
Throwaway /Yea ThrOwewaY/Yee Throwaway /Yea Throwaway !No Throwaway !No Throwaway/No
127166 25x 1 1211853541 12110x1641 1211042841 12110425x1 R110x26x1
Re010Or4n1 Chxlgell.bs.011422)' 11.00 12.13 12.20 12.00 15.13 12.20
Stmerwlona
Crated On.l
30.011x 63.5Wx 69,78E 36.014 x 53.5Wx 507821 36.014x 63.6W x69.7921 36.08 a 43.6W x 89.761. 36.064x 63.5W 469.761. 30.0114 53.6W 69.7521
Welptat
tplyttLe.1 6 05 3 518 4 500 �_4Il 480
Net lLblba.l 6003 503 485 456 483 5 4$8
NO1ESI
1. ROM in accordance w1M AAI. Standard 240.
2. Rated in accordance with 001 test procedure. HBPF Is at Ma minimum design re4uit°m 01 to Re91on W,
3. Salad in accordance with AA.1. Standard 270.
4. Std. ducky collaut1001.
5. Approximate value. 907 mom 4146e0 value, 50o4nit nameplate and ee,o4Ca lnetluatIUn,.
b()t
A 4( 414'
\0),
(9 4/
e‘') 5
Old boa
Location and Recommendations
Unit Support
If unit is to be roof mounted check building codes for
weight distribution requirements. Refer to accessory roof
curb mounting Instructions.
Location and Clearances
Installation of unit should conform to local building codes
and the National Electrical Code. Canadian installations
must conform to CSA and local codes.
Select a location that will permit unobstructed airflow into
the condenser coil and away from the fan discharge and
permit unobstructed service access into the compressor
compartment. Suggested airflow clearances and service
clearances are given. in Figure 2.
Placing and Rigging
Rig the unit using either belt or cable slings. The sling eye-
let must be placed through the lifting holes in the base rail
of the unit. The point where the slings meet the lifting eye-
let should be at least 6 feet above the unit. Use spreader
bars to prevent excessive pressure on the top of the unit
during lifting. Figure 3 shows the unit center of gravity and
rigging recommendations.
IMPORTANT :: The use of "spreader bars" is re-
quired when hoisting the unit (prevents damago to
sides and top). Top crating can be used as
spreader bars.
urrrno otAR
'ATu
on C IMN
CLEVId ROLM IR OA%
WAIL
oltrtEH or ARA11IlY
`Ct�0 on11W\TITY
Roof Mounted Units
Downflow units should be mounted on a roof curb when
possible. When Installing the unit on the roof curb, follow
the Installation instructions accompanying the roof curb kit.
On new roofs, the curb should be welded directly to the
roof deck. For existing construction, nailers must be In-
stalled under the curb if welding Is not possible. Be sure to
attach the downflow ductwork to the curb before setting
unit In place. See Figure 2.
t, 0 v\
Installation
8
When installing the unit, it must be level to insure proper
condensate flow from the unit drain pan.
Slab Mount
For ground level installation, the unit base should be ad•
equately supported and hold the unit near level. The instal-
lotion must meet the guidelines set forth in local codes."
Table 1
Corner Weights & Center of Gravit
Unit
Models
Net
Weight
Corner Wts. (Ibs)
Length
Width
A
8
C
D
WC'036
565
36
19
193
140
107
125
WC*048
587
36
19
196
144
112
135
WC "060
602
36
20
199
149
115
139
WC"063
687
39
21
224
174
129
160
WC'07)
687
39
21
224
174
129
160
WC`073
719
39
20
248
181
131
159
WC*090
719
39
20
248
181
131
159
Downflow or Horizontal
Note: Corner weights are given for information
only. Unit 1s to be supported continuously by curb
or equivalent frame support
Ductwork
Attaching Downflow Ductwork to The Roof Curb
The following warning complies with State of California
law, Proposition 65.
,�► WARNING-
. This product contains
fiberglass wool insulation) Fiberglass dust and
ceramic fibers are believed by the state of Califor-
nia to cause cancer through inhalation.
Giesswool fibers may also cause respiratory, skin,
or eye Irritation. See page 1T for precautionary
and first aid measures.
Supply and return air flanges are provided on the roof curb
for easy duct installation. All duct work must be run and at-
tached to the curb before the unit Is set Into place. See
Figure 2 for duct connections.
Ductwork construction guidelines:
Connections to the unit should be made with three -inch
canvas connectors to minimize noise and vibration trans-
mission.
Elbows with turning vanes or splitters are recommended to
minimize air noise and resistance.
07 -02 -2012
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
BUD WARE
109 WASHINGTON BL STE B
ALGONA WA 98001
RE: Permit No. M12 -020
REIT MANAGEMENT & RESEARCH
617 INDUSTRY DR TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 08/28/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 08/28/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File: Permit File No. M12 -020
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431 -3670 • Fax 206 -431 -3665
ttia.
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M12 -020 DATE: 02 -09 -12
PROJECT NAME: REIT MANAGEMENT & RESEARCH
SITE ADDRESS: 617 INDUSTRY DR - BLDG4
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Issued
DEPARTMENTS:
l� 69' iti,
Building Division
Public Works
/X1M - C
Pr
Fire Prevention
Structural
Planning Division
Permit Coordinator
n
1
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
n
DUE DATE: 02 -14-12
Not Applicable
Comments:
Permit Center Cl.. e. Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
n
APPROVALS OR CORRECTIONS:
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 03-13 -12
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Pr}'ytter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with LEt1 to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name FIVE STAR MECHANICAL UBI No. 601937083
Phone 2538528284 Status Active
Address 109 Washington Blvd Ste B License No. FIVESM'010JT
Suite /Apt. License Type Construction Contractor
City Algona Effective Date 4/30/1999
State WA Expiration Date 4/30/2012
Zip 98001 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty 1
Specialty 2
Effective
Date
Expiration
Date
Status
COMFOM1015LA
COMFORT
MECHANICAL
INC
Construction
Contractor
Heating /Vent /Air
-Conditioning
And Refrig
(Hvac/R)
Unused
6/1/1999
6/1/2012
Active
COMFOP'064D2
COMFORT
PLUS
Construction
Contractor
Air Conditioning
Mr
Ai Heat,Ventilation,Evaporat
3/22/19943/21/2000
Until Cancelled
Archived
FIVESSE941KU
FIVE STAR
ENERGY
SOLUTIONS
Construction
Contractor
General
Unused
5/24/20065/24/2008
04/27/2005
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
WARE, GERALD LAVON
Member
01/01/1980
Bond Amount
WARE, JOHN EDWARD
Member
06/10/2010
9899743
ALLEN, ANGELA RENEE
Member
06/10/2010
WARE, BETTY J
Member
06/10/2010
OLD REPUBLIC
SURETY CO
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
3
FEDERATED MUTUAL
INS CO
9899743
06/25/2006
Until Cancelled
$12,000.0006/05
/2006
2
OLD REPUBLIC
SURETY CO
YLI237591
04/30/2002
Until Cancelled
06/25/2006
$12,000.0003/04
/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
8
FEDERATED
SERV /MUT INS
CO
9434226
04/27/2007
04/27/2012
$2,000,000.0003
/21/2011
7
FEDERATED
MUTUAL INS CO
9434226
04/27/2005
04/27/2007
$1,000,000.0003
/27/2006
6
FEDERATED
MUTUAL INS CO
5048251
04/27/2005
04/27/2006
$1,000,000.00
04/26/2005
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
03/01/2012