HomeMy WebLinkAboutPermit M12-020 - REIT MANAGEMENT AND RESEARCHREIT MANAGEMENT & RESEARCH 617 INDUSTRY DR EXPIRED 08 -28 -12 M12-020 City olikukwila n Z Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2523049008 Address: 617 INDUSTRY DR TUKW MECHANICAL PERMIT Project Name: REIT MANAGEMENT & RESEARCH Permit Number: M12 -020 Issue Date: 03/01/2012 Permit Expires On: 08/28/2012 Owner: Name: BLUE DOG PROPERTIES TRUST Address: THOMSON REUTERS TRUST , 2235 FARADAY AVE SUITE 0 92008 Contact Person: Name: BUD WARE Address: 109 WASHINGTON BL STE B , ALGONA WA 98001 Email: BUDW @FIVESTARMECH.COM Contractor: Name: FIVE STAR MECHANICAL Address: 109 WASHINGTON BLVD STE B , ALGONA WA 98001 Contractor License No: FIVESM *010JT Phone: 253- 852 -8284 Phone: 253- 852 -8284 Expiration Date: 04/30/2012 DESCRIPTION OF WORK: REMOVE & REPLACE (2) EXISTING HEAT PUMPS - 6 TON AND 4 TON Value of Mechanical: $20,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: (JaR- Fees Collected: $428.56 International Mechanical Code Edition: 2009 Date: '‘"?•—• 12 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: e r� 2C) 4/ p'z' 7-7 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12-020 Printed: 03 -01 -2012 PERMIT CONDITIONS Permit No. M12-020 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Readily accessible access to roof mounted equipment is required. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this doc: IMC -4/10 M12-020 Printed: 03 -01 -2012 project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: IMC -4/10 M12 -020 Printed: 03 -01 -2012 • • CITY OF TUKWILA Community Development Departn►ent Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http : / /www.TukwilaWA.gov Mechanical Permit No. _____Nic>2_Org.. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION / y ) fl King Co Assessor's Tax No.: Site Address: d /7 .F /idgs lity A r iue. 7 Jell Tenant Name: �J PROPERTY OWNER Name: Q Re i+ /11441 e,Ylort 4_ 1■ e SeGrc_i) 1 4 /7 e ssIn Qc frii. f$sft itie City: p .T� 1c_wi /a . /115 efifa i CONTACT PERSON — person receiving all project communication Name: Q1 0 wGrc° iD q ePica shh 0 ibn OW S4e a CV. ,cf 1 oh 0. • State,; ,, Zip 1god_ Phone: DI 5?— lib 2-Ti t Fax: 253 -vs a.- g -i. O S Email: & d ii .P iUP Star A' ° c_h, cowl Suite Number: Floor: New Tenant: ❑ Yes ❑ .. No MECHANICAL CONTRACTOR INFORMATION Company Name: Ft jc 6kr .Jr.eactri i C4' Ad ess: /O . waghr lq,on $ Iua 54 3 City:d-r State :W A Zie e,oi lgsh‘ '1 Phone:a — —I ca b _ Faxb. ate , $ 6- 72-1 Co Contr Reg No.: F zvE s ml 94 Exp Dptee .5 T (� Tukwila Business License No.: Valuation of project (contractor's bid price): $ `�V Opp Describe the scope of work in detail: Remove 4- 12ep k e \ec pLA- v'h.ps a % -ov Curia a 1-t tovk Use: Residential: New Commercial: New Fuel Type: Electric Gas Replacement Replacement Iss Other: H:\ ppltcations \Form- Applications On Lme\2011 Apphcanons\Mechanical Pemut Application Revised 8- 9- 11,docx Revised: August 2011 bh Page 1 of 2 z Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall /floor mounted heater Appliance vent Repair or addition to heatlrefrig /cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial. Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler /Compressor QtY 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER AUT ZED � NT: Signature: /sp Date: 2- .2'1� -- Print Name: 6-c r q 1.4 L. Q l-e r• Day Telephone: Mailing Address:b 5 W qgl-,; n� Nuek S } e 3 IAAl t31r1 c_ tL) A q $ City State Zip H:\ Applications \Forms- Applications On Line\2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.uv RECEIPT ParcelNo.: 2523049008 Permit Number: M12 -020 Address: 617 INDUSTRY DR TUKW Status: APPROVED Suite No: Applied Date: 02/09/2012 Applicant: REIT MANAGEMENT & RESEARCH Issue Date: Receipt No.: R12 -00882 Payment Amount: $342.85 Initials: WER Payment Date: 03/01/2012 03:38 PM User ID: 1655 Balance: $0.00 Payee: FIVE STAR MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 37518 342.85 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 342.85 Total: $342.85 doc: Receipt -06 Printed: 03 -01 -2012 City of Tukwila Departinent of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: Permit Number: M12-020 Address: 617 INDUSTRY DR TUKW Status: PENDING Suite No: Applied Date: 02/09/2012 Applicant: REIT MANAGEMENT & RESEARCH Issue Date: Receipt No.: R12 -00579 Initials: TLS User ID: 1670 Payment Amount: $85.71 Payment Date: 02/09/2012 01:12 PM Balance: $342.85 Payee: GERALD WARE WARE ENTERPRISES INC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 51902G ACCOUNT ITEM LIST: Description 85.71 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 85.71 Total: $85.71 doc: Receiot -06 Printed: 02 -09 -2012 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. E SEPARATE PERMIT IT REQUIRED FOR: ❑ Mechanical 'Qt Electrical Plumbing Gas Piping City of Tukwila BU j...DiNG DIVISION r New 1-14-on GS/ Feu) • 2b rnd s4-ry ) 'ive (A1C 101) 1)3J 9 %o01_ T3 Lti( cit 2-1 FILE COPY Penult No.. pq Z- '—n` , Phan review approval is subject to errors and OrtiSE401111. Approval of construction documents dons not authorize tit. violation of any adopted code or ordinance. Receipt of approved Reid yand .edged: By •fr Dar 3f 1 -l2 City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 3 2012 City=�.�. of u ila BUILDING VISION RECEIVED FEB 09 2012 ?ERMITCENTER 1.1-4- 020 James W. Ashley -Cole, P.E. CONSULTING ENGINEER CALCULATION SUBMITTAL For Five Star Mechanical. FILE COPY Permfl Mo. HVAC Up -Grade 617 Industry Drive - • Building] Tukwilla WA IA I Xler 010 Project No. 2012.06 February 1, 2012 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 3 2012 City of Tukwila BUILDING DIVISION RECEIVED FEB 09 2012 PERMITGENTER Extent of Analysis; The structural details, general notes, and sealed engineering calculations included with this submittal have been prepared exclusively for the above referenced project. This submittal has been limited to the design of the HVAC gravity support and seismic anchorage. No other aspect of the existing structure has been addressed by this submittal. • The condition of the roof was observed to be in good condition. In my opinion the roof is suitable for the support of the proposed replacement units. • All flashings, coatings, membranes and sealants are by others. Design Criteria: Actual Equipment Weights: Roof: 25 PSF Seismic: Sds( Seismic Design Category D) = 0.8334, Rp = 2.5 Wind: 85 MPH, Exposure B 525 Columbia Street NW, Suite 201 Olympia WA 9850i t. 360.70 STRUCTURAL NOTES These structural notes apply to all structural components of the primary structural systems. Any discrepancies found among the drawings, these notes and the site conditions shall be reported to the Engineer of Record, who shall correct such discrepancy in waiting. Any work done by the Contractor after discovery of such discrepancy, but prior to correction of such discrepancy, shall be done at the Contractor's risk. • The Contractor shall field locate and identify all site utilities prior to performing any site excavation or demolition. The Contractor shall be responsible for all safety precautions and methods, techniques, sequences or procedures required to perform the Contractor's work The Consulting Engineer has no overall supervisory authority or actual and/or direct responsibility for the specific working conditions at the site and/or for any hazards resulting from the actions of any trade contractor. The Consulting Engineer has no duty to inspect, supervise, note, correct, or report any health or safety deficiencies to the Owner, Contractor, or other entities or persons at the project site. • All structural systems which are to be composed of components to be field erected shall be supervised by the supplier during manufacturing, delivery, handling, storage and erection in accordance with the written instructions prepared by the supplier. • It is the Contractor's responsibility to verify all field measurements and site conditions prior to fabrication of any structural elements. No allowance will be made for any items incorrectly fabricated or installed due to failure to perform such verification prior to commencing work. Contractor initiated changes shall be submitted to the Consulting Engineer in writing for approval prior to fabrication, construction or field modification. Changes shown on shop drawings only will not satisfy this requirement. • Non - structural building systems, including: fire resistive assemblies, ADA accessibility, thermal or moisture protection, furnishings, doors, equipment, mechanical, electrical, finishes, siding, paneling veneers, paints and coatings are not the responsibility of the Consulting Engineer. CONSTRUCTION STABILITY The design, adequacy and safety of erection bracing, shoring and all temporary supports is the sole responsibility of the Contractor, and has not been considered by the Engineer of Record. The Contractor shall provide the bracing necessary to provide stability to the structure prior to the completed application of the lateral system. During construction the Contractor shall keep loads within the design roof and floor loads limits shown on the drawings. CODES AND DESIGN All methods, materials and workmanship shall conform to the 2009 edition of the International Building Code (IBC) as amended and adopted by the local Building Department. All reference to other codes and standards, such as ACI, ASTM, AISC, etc. shall be for the latest or most current edition available. DESIGN LIVE LOADS Roof: 25 PSF Seismic: Sds( Seismic Design Category D) = 0.8334, Rp = 2.5 Wind: 85 MPH, Exposure B WOOD FRAMING AND LUMBER GRADING Allowable stress required shall be in accordance with standard grading rules of West Coast Lumber No. 16. Moisture content shall be maximum 19%. All studs, plates and blocking at shear walls, load bearing and exterior studs and plates shall be of grade Douglas-fir #2 or better, unless noted otherwise. Structural Panel Sheathing including Plywood and Oriented Strand Board (OSB) sheathing shall be APA grade trademark sheathing with nominal thickness as indicated on the contract drawings. All glue -lam beams shall be 24F -V4 UNTO as 24F -V8 at cantilever conditions. Wood framing details, not shown otherwise, shall be constructed to the minimum standards of the 2009 IBC and shall conform to the Fastening Schedule 2304.9.1. Unless noted otherwise, all nailing callouts refer to common type nails. Notations on drawings relating to framing clips, joist hangers and other connectors refer to catalog numbers manufactured by the Simpson Strong Tie Company, San Leandro, CA, Catalog C -2012. All hangers in contact with preservative treated lumber shall be "Z -MAX" galvanized with approved fasteners as noted. SECTIONS AND DETAILS Sections and details showing reinforcing, bolts, framing members, and connections are intended to illustrate specific detail. No attempt has been made to show all elements passing through a specific section or detail. Exposed bolted beam connections may have to be furred by the Contractor to conceal connector. Construction details not specifically shown on the drawings shall follow similar details or sections of this project as approved by the Engineer. SPECIAL INSPECTION An independent third party Special Inspector shall be retained by the Owner for the following: • Any item required by the Building Official. CONSTRUCTION OBSERVATION The Contractor shall notify the Engineer of Record for observation of The following: • Any item required by the Building Official. ON$ULT NG ENGINEER z+ - 1.(#-/".6. -.0 1W 4 - _ - - 7. 111N --t.-.b7"- -- e ---_____ .ra. o -- f 'gib - -. ../.'0f;91..._ CF. - Zi L‘zZ VP -sc - .. -- / ok4). - 9p'Iz >f 1 133HS 1A1111■11Taf &I k133NION3'JNillfl NO g• ` 103- apl1sy A/ saws/' ON UL1ING ENGINEER e Lid Li 4-0q r�1t�f w ®lo --- • WO (A WA A WCC3O48A- SUB -1 E TAG: 4 Ton Convertible Heat Pump Packaged Units 2/4WCC3048A1000A PRODUCT SPECIFICATIONS MODEL 2WCC3048A1000A 4WCC3040A1000A RATED Volts/Ph/Hz 208- 230/1/60 208 - 23011/60 RATINGS (COOL) CO BTUH 46000 48 Indoor Airflow (CFM) 1600 1600 Power Input (KW) 423 4.33 EER/SEER (BTUM1att-Hr.)® 11/13 10.75/13 Sound Power Rating (dB(A))® 79 80 (High Temp.) BTOH� Power Input (KW) (Low Temp.) BTUH Power Input (KW) HSPF (BTU / Watt-Hr.) O POWER Min. t r3 dt. Cir Ampacity W Fuse Size —Max. (Amps) Fuse Size — Recmd. (Amps) 46500 3.52 28200 2.95 7.70 208-230/1/60 28.6 46 46 47000 3.92 28200 3.65 7.70 208. 230/1/60 31.1 50 60 vg FSSOR R.L. Amps --L.R. Amps OUTDOOR COIL —TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) ReMgerant Control INDOOR COIL —TYPE ow .1. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (In.) OUTDOOR PAN -- TYPE ta. (tin.)) Drive/No. Speeds CFM 0.0 In. w.g. O Motor —HP / R.P.M. . Volts/Ph/Hz F.L. Arnps/L.R. Amps DIaDWidihF(N —TYPE Drive / No. Speeds CFM v.s. IN. W.S.® Motor —HP / R.P.M. Volts/Ph/Hz F.I.. Amps/L.A. Amps Vype Recommended D7 Min. Face Area (sq. ft.) REFRIGERANT (I GIMEN$IONS Crated (in.) LIGHT aping (lbs.) / Net (Ibs.) Cot 2010 Tram) 200-230/1/60 18.6193.4 SPINE FIN 2/24 20.98 3/8 EXPANSION VALVE PLATE FIN 4/15 6 3/8 EXPANSION VALVE 3/4 FEMALE,., f�PT PROPELLER 27.6 DIRECT /1 4400 1/4/825 230/1/60 1.4/3.1 CENTRIFUGAL 1�0�xO10 SEE FAN PERF TABLE 314 /1080 200- 230/1/60 4/8.4 NO THROWAWAY 5.3 (R -22) 726 HXWXD 49.86X47.4X61.75 200-230/1/60 20.5/109 SPINE FIN 2/24 18.01 3/8 EXPANSION VALVE PLATE FIN 4/15 6 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.8 DIRECT /1 4400 1/4/825 230/1/80 1.4/3.1 CENTRIFUGAL 10 x 10 p L3 SEE FANRPpERF TABLE 3/4/1080 200-230/1/60 4/8.4 NO THROWAWAY 5,3 (R -410A) 7.75 HXWXD 47.86X47.4X61.75 553/425 553/ CU Certified In accordance with the Unitary Air - Conditioner Equipment certification program, which Is based on ARI Standard 210/240. ®Sound Powerval uesere not adjustedlorAR1270- 95 tonal corrections. 0 Calculated in accordance with currently prevailing Nat'l Electrical Coda. C) Standard Air— Dry Coil — Outdoor. 11 Standard Air — Wet Coil — Indoor. (5 Rated In accordance with O.O.E. test procedure. (/) t=iters must be installed In return air system. Square tooteges listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05• W.C. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 3 2012 City of Tukwila BUILDING DIVISION 11 2'o2o RECEIVED FEB 09 2012 PERMITCENTER eu) Installation 40(1 AWARNING Heavy Objects! Ensure that all the lifting equipment used is properly rated for the weight of the unit being lifted. Each of the cables (chains or slings), hooks, and shackles used to lift the unit must be capable of supporting the entire weight of the unit. Lifting cables (chains or slings) may not be of the same length. Adjust as necessary for even unit lift. Other lifting arrangements could cause equipment or property damage. Failure to follow instructions above or properly lift unit could result in unit dropping and possibly crushing operator /technician which could result in death or serious injury. AWARNING Improper Unit Lift! Test lift unit approximately 24 inches to verify proper center of gravity lift point.To avoid dropping of unit, reposition lifting point if unit is not level. Failure to properly lift unit could result in unit dropping and possibly crushing operator /technician which could result in death or serious injury and possible equipment or property -only damage. Table 1. Maximum unit & comer weights (Ibs) and center of gravity dimensions (in.) Unit Tons Model No. 3 WSC036E 4 WSC048E 5 WSC060E W SC072E 7'h WSC090E 10 WSC120E tc 6Th Maximum Model Weights(a) Corner Weights(b) Center of Gravity (in.) Shipping Net A B C D Length Width 589 514 177 107 113 117 29 20 600 525 181 109 115 119 29 20 825 682 228 177 114 163 38 24 835 740 235 196 140 168 40 22 902 804 255 217 153 180 41 22 1431 1219 355 333 257 274 48 28 (a) weights are approximate. (b) Corner weights are given for information only. RT- SVX23E -EN Figure 12. Comer weights A CENTER OF GRAVITY -.10-- LENGTH CENTER OF GRAVITY WIDTH D CENTER OF GRAVITY 21 General Data Lil-ovi Table 2 General Data 4 TON DOWNFLOW & HORIZONTAL 01 1CA WC0048A3 WC11049A3 WCOO48A1 WCD048A4 WC0048AW WCH048A1 WCH040A4 W CH048AW GenoralDeto COalinGPMOrmenCe' 0ro,sCoo1in3C0p•dty 61400 61400 60400 51400 61400 60300 A. Mt. Mel tooting Capacity 49000 49000 48000 49000 48000 98000 00816515' 8.00/10.20 9.001- 9.001- 5.00/10.20 9.00,- 0.001 - Nominal Cho 1600 1000 1800 1800 1800 1600 9ymeln Kw 6.44 5.44 6.32 6.44 6.44 5.33 A.R.I. Sound Rndn916E181' 8.8 8.8 9.0 8.8 9.6 8.8 HatingtHeelinpl' 1140112e150.18tdt 48500 47500 48000 48600 47500 48000 51/310m Power (Kw end 0091 4.7413.00 4.49/3.10 4.08(3.00 4.74/3.00 4.49/310 4.8813.00 11.OWTamp2 Mull 20000 24000 26000 20000 54000 25000 8yatent POwar (Kw and COP) 3.89(2.00 3.69/2.00 3.07/2.00 3.89/2.00 3.5912.00 2.0712.00 HSPF(Otu/Watohr.P 7.00 - - 7.00 - - Commute / -No.n m• I /C6nendr 1 /Clhnatut1 11CIhmtN1' 1 /Climatal1. 11C11meIv11' 1 /CFmetuII` Indoor Coil -Type Platt Fin Plate Fin P1614 FM Plate Fin /101, Fla Plata fin Tube Site liU.! .30 .38 .39 .08 .38 .30 Fess Area 184. FO1 5.49 5.48 6.49 6.49 5.43 6.49 Rowe /PM 4/12 4/12 4.12 4.12 4.12 4.12 Rordgerant Cennrol Expansion Valve Eapanaton VONa Cepon/1en Valve 65501410a Viva Espemlon Volvo 6xpantlon Valve Drain Conn. Size Yn.I 110/ PVC M "PVC %'PVC 11. PVC 16. PVC 6'PVC Outdoor Cell-A/pa Plele Nn Plate Fin Mme Nn Plate Fin Mete Fin F1510 FM 81174 Sim lis.l 001 .30 .38 .38 .38 30 .30 Feel Mee ISO. Ft.1 14.8 19.8 14.8 19.8 14.8 14.8 HowlfFF7 2/16 2116 2(16 2/15 2118 2/15 ROfn00ran1 COntrO1 Expansion V4100 exponvon Valve Espwuto0 Valve e.oNIalea V4140 101,04104 1411V81 18Penata4 Were 1n000lpen -Type Cfinelu84( Centdru9al Can1IF5900 Centil(u541 Cenanupel Canld)ugdl Moto, Hp .78 .78 .76 .76 .76 .76 O.ire /Speed4NO.1 O6ecs/3 Ohect /$ 01,0.119 01,0.113 01rest/3 OFrou113 No. Used 1 1 1 1 1 1 OM. xW1dhlln.) 11.0x0.5 11.0,9.5 11.8,9.8 11.0x8.6 11.0x8.5 11.0x9.5 Motor Rpm 1078 1075 1079 1075 1075 1076 Outdoor Fan -Typo Proposer Propeller Propeller P.epolar Propellor 9,494051 No. 1.1444-01o.157.1 1123 1/22 1/22 1/22 1/22 1/32 Onw,9paed INe3 01.441/1 Do401 /1 Cheat/1 Obect/I Ohe.1 /I Olreet /1 Cfm4 4900 4800 4800 4800 4800 4800 No. Motors -Hp 1 /.50 11.50 1/.50 1/.60 11.60 1 /.50 Rpm 1075 1075 1076 1076 1075 1075 Filel. - TypeIFINnlrhad1 No. /SlmReeemmandad Throwaway /Yea ThrOwewaY/Yee Throwaway /Yea Throwaway !No Throwaway !No Throwaway/No 127166 25x 1 1211853541 12110x1641 1211042841 12110425x1 R110x26x1 Re010Or4n1 Chxlgell.bs.011422)' 11.00 12.13 12.20 12.00 15.13 12.20 Stmerwlona Crated On.l 30.011x 63.5Wx 69,78E 36.014 x 53.5Wx 507821 36.014x 63.6W x69.7921 36.08 a 43.6W x 89.761. 36.064x 63.5W 469.761. 30.0114 53.6W 69.7521 Welptat tplyttLe.1 6 05 3 518 4 500 �_4Il 480 Net lLblba.l 6003 503 485 456 483 5 4$8 NO1ESI 1. ROM in accordance w1M AAI. Standard 240. 2. Rated in accordance with 001 test procedure. HBPF Is at Ma minimum design re4uit°m 01 to Re91on W, 3. Salad in accordance with AA.1. Standard 270. 4. Std. ducky collaut1001. 5. Approximate value. 907 mom 4146e0 value, 50o4nit nameplate and ee,o4Ca lnetluatIUn,. b()t A 4( 414' \0), (9 4/ e‘') 5 Old boa Location and Recommendations Unit Support If unit is to be roof mounted check building codes for weight distribution requirements. Refer to accessory roof curb mounting Instructions. Location and Clearances Installation of unit should conform to local building codes and the National Electrical Code. Canadian installations must conform to CSA and local codes. Select a location that will permit unobstructed airflow into the condenser coil and away from the fan discharge and permit unobstructed service access into the compressor compartment. Suggested airflow clearances and service clearances are given. in Figure 2. Placing and Rigging Rig the unit using either belt or cable slings. The sling eye- let must be placed through the lifting holes in the base rail of the unit. The point where the slings meet the lifting eye- let should be at least 6 feet above the unit. Use spreader bars to prevent excessive pressure on the top of the unit during lifting. Figure 3 shows the unit center of gravity and rigging recommendations. IMPORTANT :: The use of "spreader bars" is re- quired when hoisting the unit (prevents damago to sides and top). Top crating can be used as spreader bars. urrrno otAR 'ATu on C IMN CLEVId ROLM IR OA% WAIL oltrtEH or ARA11IlY `Ct�0 on11W\TITY Roof Mounted Units Downflow units should be mounted on a roof curb when possible. When Installing the unit on the roof curb, follow the Installation instructions accompanying the roof curb kit. On new roofs, the curb should be welded directly to the roof deck. For existing construction, nailers must be In- stalled under the curb if welding Is not possible. Be sure to attach the downflow ductwork to the curb before setting unit In place. See Figure 2. t, 0 v\ Installation 8 When installing the unit, it must be level to insure proper condensate flow from the unit drain pan. Slab Mount For ground level installation, the unit base should be ad• equately supported and hold the unit near level. The instal- lotion must meet the guidelines set forth in local codes." Table 1 Corner Weights & Center of Gravit Unit Models Net Weight Corner Wts. (Ibs) Length Width A 8 C D WC'036 565 36 19 193 140 107 125 WC*048 587 36 19 196 144 112 135 WC "060 602 36 20 199 149 115 139 WC"063 687 39 21 224 174 129 160 WC'07) 687 39 21 224 174 129 160 WC`073 719 39 20 248 181 131 159 WC*090 719 39 20 248 181 131 159 Downflow or Horizontal Note: Corner weights are given for information only. Unit 1s to be supported continuously by curb or equivalent frame support Ductwork Attaching Downflow Ductwork to The Roof Curb The following warning complies with State of California law, Proposition 65. ,�► WARNING- . This product contains fiberglass wool insulation) Fiberglass dust and ceramic fibers are believed by the state of Califor- nia to cause cancer through inhalation. Giesswool fibers may also cause respiratory, skin, or eye Irritation. See page 1T for precautionary and first aid measures. Supply and return air flanges are provided on the roof curb for easy duct installation. All duct work must be run and at- tached to the curb before the unit Is set Into place. See Figure 2 for duct connections. Ductwork construction guidelines: Connections to the unit should be made with three -inch canvas connectors to minimize noise and vibration trans- mission. Elbows with turning vanes or splitters are recommended to minimize air noise and resistance. 07 -02 -2012 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director BUD WARE 109 WASHINGTON BL STE B ALGONA WA 98001 RE: Permit No. M12 -020 REIT MANAGEMENT & RESEARCH 617 INDUSTRY DR TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 08/28/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 08/28/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M12 -020 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431 -3670 • Fax 206 -431 -3665 ttia. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -020 DATE: 02 -09 -12 PROJECT NAME: REIT MANAGEMENT & RESEARCH SITE ADDRESS: 617 INDUSTRY DR - BLDG4 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: l� 69' iti, Building Division Public Works /X1M - C Pr Fire Prevention Structural Planning Division Permit Coordinator n 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 02 -14-12 Not Applicable Comments: Permit Center Cl.. e. Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03-13 -12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pr}'ytter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEt1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name FIVE STAR MECHANICAL UBI No. 601937083 Phone 2538528284 Status Active Address 109 Washington Blvd Ste B License No. FIVESM'010JT Suite /Apt. License Type Construction Contractor City Algona Effective Date 4/30/1999 State WA Expiration Date 4/30/2012 Zip 98001 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status COMFOM1015LA COMFORT MECHANICAL INC Construction Contractor Heating /Vent /Air -Conditioning And Refrig (Hvac/R) Unused 6/1/1999 6/1/2012 Active COMFOP'064D2 COMFORT PLUS Construction Contractor Air Conditioning Mr Ai Heat,Ventilation,Evaporat 3/22/19943/21/2000 Until Cancelled Archived FIVESSE941KU FIVE STAR ENERGY SOLUTIONS Construction Contractor General Unused 5/24/20065/24/2008 04/27/2005 Expired Business Owner Information Name Role Effective Date Expiration Date WARE, GERALD LAVON Member 01/01/1980 Bond Amount WARE, JOHN EDWARD Member 06/10/2010 9899743 ALLEN, ANGELA RENEE Member 06/10/2010 WARE, BETTY J Member 06/10/2010 OLD REPUBLIC SURETY CO Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 FEDERATED MUTUAL INS CO 9899743 06/25/2006 Until Cancelled $12,000.0006/05 /2006 2 OLD REPUBLIC SURETY CO YLI237591 04/30/2002 Until Cancelled 06/25/2006 $12,000.0003/04 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 FEDERATED SERV /MUT INS CO 9434226 04/27/2007 04/27/2012 $2,000,000.0003 /21/2011 7 FEDERATED MUTUAL INS CO 9434226 04/27/2005 04/27/2007 $1,000,000.0003 /27/2006 6 FEDERATED MUTUAL INS CO 5048251 04/27/2005 04/27/2006 $1,000,000.00 04/26/2005 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 03/01/2012