Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M12-028 - EL MATADOR APARTMENTS
EL MATADOR APTS 14828 MILITARY RD S M12 -028 City IfTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0041000070 Address: 14828 MILITARY RD S TUKW Project Name: EL MATADOR APARTMENTS Permit Number: Issue Date: Permit Expires On: M12 -028 03/06/2012 09/02/2012 Owner: Name: CEDERLIND JIM Address: 8040 23RD AVE NW , SEATTLE WA 98117 Contact Person: Name: Address: Email: Contractor: Name: OLEG KOT 13406 PACIFIC POINT LN , MUKILTEO WA 98275 COMFORTSOLUTIONINC @GMAIL. COM COMFORT SOLUTION INC Address: 13406 PACIFIC POINT LN , MUKILTEO WA 98275 Contractor License No: COMFOSI905O2 Phone: 425 343 -6157 Phone: 425 - 742 -4265 Expiration Date: 09/22/2012 DESCRIPTION OF WORK: UNITS 107, 108, 206, 207 & 208: INSTALL VENT PIPES FOR (5) KITCHEN HOODS AND (4) BATHROOM FANS Value of Mechanical: $3,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Fees Collected: $221.38 International Mechanical Code Edition: 2009 The granting of this permit does not press construction or the performance of work. back of this permit. Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. oAculi4, ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. me to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: 3- doc: IMC -4/10 M12 -028 Printed: 03 -06 -2012 • PERMIT CONDITIONS Permit No. M12-028 1: ** *BUILDING DEPARTMENT CONDTITONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -028 Printed: 03 -06 -2012 CITY OF TUKW Community Developm1IIIIDepartment Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE 'LOCATION / / ,(� � King Co Assessor's Tax No.: 00/O�D Site Address: l �� Z 8 "� // t 4 / /ie wi gez_ Suite Number: Floor: I '/ ,,c/a' 4 dor a fQ,-/ 6• /, /07, /08, 20(/ 207, 2Dc9 Tenant Name: PROPERTY ?,OWNEI Name: ( i 1`�t IV i l V" Address: 1�,�y/l/'v 2-' City. State: WA. Zip: lib CcONTATPRSON p eson receiing aproe m� ¢ :omuntcaton�,, Name: O/{ /4O / Address: 0,?z/(26 I; L/' rC 6 h"( /17 City: Ma j<<O State: i 74 Zip: 9/271 Phone:( 273 y3 --4/f7 Fax &°2797.2 - 2,.' 3 Email: 42/,?.71pv7/29Z, /'&,7 /0 ci g2?i/,. ep/l New Tenant: ❑ Yes 13.. No 5 MECHANICAL'xCONTRACTOR INFORMATION'. , . Company Name: `©rfr` , yez 40, ham. Address: 131106 4e,,;/..,,,e 6p / //Q/ 447 City: 4de,4 wee State: j- Zip: 94047/. Phone :029-33- 03 2 Fax: (44-942 - 2.t<5 Contr Reg No.: a/9i /OSf 9O30 xp Date: 09 ZZ_ /2_ Tukwila Business License No.: {L,,c _ 1i ; Q Valuation of project (contractor's bid price): $"'- 6962C9 Describe the scope of work in detail: 2h- 4 // ' vend fi /es gQb5. ;/'/ -2 /,'/e e 4.P. h X10,P1_9 ahc' /pup 6A /h`oo.7 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement / Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications\Forms- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type , Qty :. Furnace <100k btu Furnace >100k btu Floor furnace Suspended /wall /floor mounted heater /, '7 Appliance vent Repair or addition to heat/refrig/cooling system 5- Air handling unit <10,000 cfm Unit Type ,Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct /, '7 Ventilation system Hood and duct 5- Incinerator — domestic Incinerator — comm/industrial ,Unit�Type " ,Qty Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor` • 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signatur R OR AUTHORIZED AGENT: -C9 - /Z Date: Print Name: t floes- Day Telephone: Mailing Address: (/ City H:\Applications\Forms- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0041000070 Address: 14828 MILITARY RD S TUKW Suite No: Applicant: EL MATADOR APARTMENTS RECEIPT Permit Number: M12 -028 Status: PENDING Applied Date: 02/23/2012 Issue Date: Receipt No.: R12 -00767 Initials: User ID: Payee: JEM 1165 Payment Amount: $221.38 Payment Date: 02/23/2012 09:39 AM Balance: $0.00 OLEG N KOT TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 03599D ACCOUNT ITEM LIST: Description 221.38 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 177.10 000.345.830 44.28 Total: $221.38 doc: Receipt-06 Printed: 02 -23 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. : PERMIT NO. :CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Projec : i J- • vA Type Qf InspectAon: Ai , /) Address: �/ a Date Called: Date Special Instructions: UATICS 1 Date Wanted:. a � Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. if COMMENTS: Date ,...- (2-. n REINSPECTION FEE REQUIRE. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila: WA 98188 i g. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 M Z -022 Project: 0 MA-74-6 0IL AP Typ of Inspection: - 0 („ 4-- _= ►. .._° Address: 1 14'2 ACS. Date Called: Special Instructions: 11 0 �� �. --!..a. - Date Wanted:. s"-F3.-3-n: e"-- a.m Requester: (.J -F"' Phon}eNom3' 1 1 __ 1d d ZApproved per applicable codes. a Corrections required prior to approval. COMMENTS: jt -- _= ►. .._° (C. , n 8 K. 77 3/((---- (.J -F"' .. ti - v I t • . • r- a ' I ( &o6k eo? aICL' . - clb a it-, i dl () l�L- -- z-,) ,LF f Inspector: A,A4-A P" Date,,, - � 2- n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Gmail - FW El Matador Apts. Fire Damage 1 of3 https: // mail. google .com /mail / ?ui= 2 &ik= 9f196437cc &view =pt &sea... Oleg Kot < comfortsolutioninc@gmail.com> Flo C 0 �liv atic or Apts F re Damage je 1 message Brian Montag <bmontag @pdr- usa.net> To: comfortsolutioninc @gmail.com Brian Montag 206 - 364 -3000 E 206- 364 -1105 IU C ©PU Penngt No. 1PAUL DAVIS RE5TORAr/ON Please consider the environment before printing this e -mail From: Andy Sandberg [ mailto: sandberg .andrew@apacengtech.com] Sent: Wednesday, February 15, 2012 3:46 PM To: steve(@rusdalconstruction.com; plea@ pdr- usa.net; Brian Montag Cc: Mike Smith Subject: El Matador Apts. Fire Damage Wed, Feb 22, 2012 at 12:14 PM REVIEWED FOR CODE COMPLIANCE APPr OVED PEAR 0 2 2012 BUILDING p�rla VISION The following, is shown in our architectural details and plans as requested by the City of Tukwila building inspector and plan reviewer to meet code requirements in the area of repairs: City Requirements and Changes Rated Assemblies 1. Provide one -hour separations at party walls and floors between units. criM: FEB 2 3 2012 PERMIT CERITER LA 2. East exterior wall at Unit 208 adjacent to other building will have (2) layers 5/8" Type 'X GWB on the interior face. 3. East exterior Soffit at unit 208 will have (2) layers of 5/8" Type 'X' Gypsum Sheathing Board. (1 -hr assembly) 4. Ceiling inside unit 208 will have (2) layers of 5/8" Type 'X' GWB (1 -hr assembly due to close p. Gmail - FWj El Matador Apts. Fire Damage https: / /mail.google.com /mail / ?ui= 2 &ik= 9f196437cc &view =pt &sea... proximity of adjacent buildings). a. New party walls will have (1) layer of 5/8" Type 'X' GWB each side with sound insulation. b. New second floor /ceiling will have 1/2 Type 'X' GWB and resilient channels with sound insulation. WA. State Energy Code Requirements 1. New exterior wall insulation is R -15 High Density batt insulation with vapor barrier. 2. New roof insulation will be blown in R -49 insulation with vapor barrier. 3. New floor insulation will be R -30 batt insulation. 4. New windows will have Max. U value = 0.32 5. New exterior doors will have Max. U value =0.40 Mechanical Vents 1. Bathroom exhaust vent locations through exterior walls shall be min. 3' -0" from operable openings. 2. Exhaust vents in unit 208 that penetrate the ceiling will have the annular space filled with noncombustible fire caulking per drawings and rerouted such that they are a min. of 5' -0" from the east exterior wall when they penetrate the roof. 3. Provide shaft enclosure in unit 207 and 208 utility closet for kitchen exhaust for units 107 and 108 below. Penetrations to be filled with noncombustible fire caulking at floor line and ceiling. Horizontal duct enclosure in the floor shall have duct enclosures of 1/2" Type 'X' GWB until vertical shaft location. 4. Exhaust vents for bathrooms in units 107 and 108 to be rerouted per drawings and to have horizontal duct enclosure of 1/2" Type 'X' GWB. 5. Exhaust vents for bathroom and kitchen in units 206 and 207 to vent through ceiling and roof. At penetration through ceiling the annular space should be filled with noncombustible fire caulking. The drawings are signed and ready for pick -up at our front desk. Thanks Andrew Sandberg Architectural Designer Pacific Engineering Technologies 1700 Westlake Ave. North Suite 100 2 of 3 2/22/2012 10:00 PM Gmail - FW El Matador Apts. Fire Damage Seattle, Washington 98109 Office #: (206) - 281 -7500 11243.wd.FULLSET.pdf 1164K https://mail.google.com/mail/?ui=2&ik=9f196437cc&view=pt&sea... 3 of 3 2/22/2012 10:00 PM ) OPERMIT COORD COP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -028 PROJECT NAME: EL MATADOR APARTMENTS SITE ADDRESS: 14828 MILITARY RD S DATE: 02/23/12 X _ Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: r- (d OS•O2- i - A� B ing Division Fire Prevention El Public Works ❑ Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 02/28/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route I4 Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/27/12 Approved ❑ Approved with Conditions' Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople liter Friendly Page General /Specialty Contractor A business registered as a construction contractor with LEN to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name COMFORT SOLUTION INC UBI No. 603041277 Phone 4257424265 Status Active Address 13406 Pacific Point Ln License No. COMFOSI90502 Suite /Apt. License Type Construction Contractor City Mukilteo Effective Date 9/22/2010 State WA Expiration Date 9/22/2012 Zip 98275 Suspend Date County Snohomish Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status COMFOH'942M4 COMFORT HEATING Construction Contractor General Unused 7/24/2006 7/24/2012 Re Licensed Business Owner Information Name Role Effective Date Expiration Date KOT, OLEG NIKOLAEVICH Agent 09/22/2010 Amount KOT, OLEG NIKOLAEVICH President 09/22/2010 C11SH5595 KOT, OKSANA V Vice President 09/22/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SH5595 09/13/2010 Until Cancelled $12,000.00 09/22/2010 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 Contractors Bonding & Insuranc C11SH5595 10/04/2010 10/04/2012 $1,000,000.0009 /16/2011 1 CBIC C11SH5595 10/04/2009 10/04/2010 $1,000,000.0009 /22/2010 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 03/06/2012 REVISIONS No changes shall be made to the scope Of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. alIMMOM FIiE DAMAGE NOTES: 1. CONTRACTOR SHALL FILE FOR AND OBTAIN THE PERMITS FOR ALL WORK AS REQUIRED BY THE LOCAL GOVERNMENT AGENCIES. 2. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 3. THE REQUIRED AND /OR IMPLIED DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE DOES NOT, AND IS NOT INTENDED TO, INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, ON, oR NEAR THE CONSTRUCTION SITE. 4. CONTRACTOR TO PROVIDE TEMPORARY BARRICADES AND OTHER FORMS OF PROTECTION TO PROTECT PUBLIC FROM INJURY DUE TO DEMOLITION WORK AND CONSTRUCTION ACTIVITY. BARRICADES ARE TO REMAIN IN PLACE AFTER DEMOLITION WORK HAS SEEN COMPLETED. 5. 17 IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE AND VERIFY ALL SITE CONDITIONS PRIOR TO START OF CONSTRUCTION. 6. PROVIDE BRACING OR SUPPORT TO PREVENT MOVEMENT OR SETTLEMENT OF STRUCTURE TO REMAIN. 1. REMOVE DEBRIS, RUBBISH AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS FROM BUILDING SITE. TRANSPORT AND LEGALLY DISPOSE OFF SITE. 8. PROVIDE PROPER WEATHER PROTECTION TO PORTIONS OF THE BUILDING EXPOSED DUE TO DEMOLITION AND CONSTRUCTION ACTIVITIES. PROTECT EXISTING FINISHES, FIXTURES, AND EQUIPMENT THAT ARE TO REMAIN FROM DAMAGE. 10. CONTACT THIS OFFICE AT (206) 281 -1500 IF ANY ADDITIONAL DAMAGE IS FOUND DURING DEMOLITION, OR ANY VARIATIONS TO THE SITE OR EXISTING BUILDINGS) THAT ARE FOUND DURING THE CONSTRUCTION WORK 11. LEAVE SITE BROOM CLEAN AFTER DEMOLITION WORK IS COMPLETE. 12. DO NOT SCALE DRAWINGS. 13. VERIFY ALL GRADES, DIMENSIONS AND EXISTING CONDITIONS AT THE SITE BEFORE PROCEEDING WITH THE WORK 14. REPETITIVE FEATURES MAY BE DRAWN OR CALLED OUT ONCE, BUT SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. 15. ALL WOOD PLATES, NAILING STRIPS, AND LEDGERS, IN CONTACT WITH CONCRETE SHALL BE PRESSURE PRESERVATIVE TREATED. CUT ENDS, ETC., SHALL BE PAINTED WITH (2) COATS OF WOOD PRESERVATIVE. 16. ALL VENTILATION OPENINGS SHALL BE SCREENED WITH THE EXCEPTION OF DRYER VENTS. 11. REPLACE ALL DAMAGED INTERIOR AND EXTERIOR DOORS AND HARDWARE WITH NEW DOORS AND HARDWARE TO MATCH EXISTING. I8. ALL WORKMANSHIP SHALL BE OF THE HIGHEST QUALITY AND IN ACCORDANCE WITH INDUSTRY STANDARDS AND MANUFACTURER'S SPECIFICATIONS, DIRECTION AND RECOMMENDATIONS. 19. GENERAL CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE BY OWNER. 20. REMOVE CHAR AND SMOKE SEAL EXISTING FRAMING TO REMAIN. 21. ALL NEW PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH WASHINGTON STATE PLUMBING CODE AMENDMENT RCUJ 1921.110. 22 ALL GLAZING IN DOORS AND WINDOWS IN SPECIFIC HAZARDOUS LOCATIONS SHALL BE TEMPERED OR SAFETY GLASS IN ACCORDANCE WITH SEC. 2406 !B.C. 23. MECHANICAL AND ELECTRICAL REPAIR WORK TO BE BIDDER DESIGNED AND SHALL BE PERFORMED UNDER A SEPARATE BUILDING PERMIT. ALL NEW MECHANICAL AND ELECTRICAL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE WASHINGTON STATE ENERGY CODE (WAC 51 -I1). 24. MECHANICAL EXHAUST DUCTS WHICH PENETRATE FIRE RESISTIVE FLOOR/CEILING OR ROOF /CEILING ASSEMBLIES SHALL BE FIRE DAMPERED OR WITHIN FIRE RESISTIVE SHAFTS, PER IBC SEC. 113. 25. PROVIDE AIR LEAKAGE CONTROL AT ALL CRITICAL AREAS: EXTERIOR JOINTS AT WALLS AND FLOORS, WIRING, FAN, VENT AND PIPE PENETRATIONS AND AT PERIMETER WINDOWS AND DOOR FRAMES IN ACCORDANCE WITH WASHINGTON STATE ENERGY CODE. 26. PROVIDE PENETRATION FLASHING AT ALL DOORS, WINDOWS AND SLIDING GLASS DOORS TO BE REPLACED. INSTALL PENETRATION FLASHING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS AND INACCORDANCE WITH INDUSTRY STANDARDS. 21. AN OPENING NOT LESS THAN 22 "x30" SHALL BE PROVIDED TO ANY ATTIC AREA EXCEEDING 30 SQ. FT. AND HAVING A VERTICAL HEIGHT OF OVER 30 INCHES. A 30" INCH MINIMUM CLEAR HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT OR ABOVE THE ACCESS OPENING. 28. PROVIDE FIRE BLOCKING AND ATTIC DRAFT STOPS IN ACCORDANCE WITH SECTION 111 OF THE IBC. SEPAR)) T E PERMIT REQUIRED FOR: ❑ Mechanical Electrical Plumbing Gas Piping ciriy cf Tukwila Irs I,Ei_E.')lcli DIVISION PROJECT NARRATIVE THE PURPOSE OF THESE SUPPLEMENTAL DRAWINGS (SD -A1, 8D -A2, SD -AD1, AND SD -AD2) IS TO SHOW THE DETAILS NECESSARY TO REPAIR UNIT FLOOR/ WALL ASSEMBLIES AND PENETRATIONS CAUSED BY A RECENT FIRE AND TO RESTORE THE BUILDING TO ITS PRE -FIRE DAMAGED CONDITION. THE GENERAL LAYOUT OF THE UNITS SNOW THE APPROXIMATE LOCATIONS OF CABINETRY, FIXTURES, APPLIANCES AND REQUIRED EXHAUST VENTILATION. NO REVIEW HAS BEEN MADE OF THE ADEQUACY OF UNDAMAGED FRAMING MEMBERS. ARCHITECTURAL DETAILING SUCH AS, BUT NOT LIMITED TO: ROOFING, WATERPROOFING, EXTERIOR SIDING, FLASHING, VENTILATION, WINDOWS, DOORS, ETC. IS NOT INCLUDED IN THIS DRAWING. MECHANICAL AND ELECTRICAL WORK SHALL BE PERFORMED UNDER A SEPARATE BUILDING PERMIT. ALL MECHANICAL AND ELECTRICAL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE STATE OF WASHINGTON. REFER TO DRAWINGS TITLED "EL MATADOR APARTMENTS FIRE DAMAGE REPAIR" BY PACIFIC ENGINEERING TECHNOLOGIES, INC., DATED 9/6/11, REVISED 9/28/11 FOR ALL NOTES, PLANS AND DETAILS NOT SHOWN ON T1 -IESE DRAWINGS. 15UILDING DATA: CODE: OCCUPANCY: R -2 BUILDING AREA: BUILDING HEIGHT: NUMBER OF STORIES: ORIGINAL SUILiDING CONSTRUCTION: CURRENT BUIL1�� �ING CONSTRUCTION: TOTAL NUMBEROF UNITS: 2009 INTERNATIONAL BUILDING CODE (I.5.C.), WITH WASHINGTON STATE AMENDMENTS R -2 1,400 ± F. (3,100' S.F. / FLOOR) 30' -0" t (EXISTING) 2 TYPE VN TYPE VS (2009) I.B.G. 12 UNITS (6 PER FLOOR) BUILDING ENVELOPE REQUIRE ENTS (FOR AREAS WHERE INSULATION, DOORS 4 WINDOWS TO 5E REMOVED AND REPLACED) ATTIC/ROOF EXTERIOR WALL FLOOR R -49 AT FRAMING/TRUSSES IN ATTIC R -I5 BETWEEN EXIST 2x4 STUDS R -30 AT CRAWL SPACE GLAZING (VERT) u =032 MAX. DOORS u = 0.40 MAX. REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 2 2012 City of Tu wile BUILDING !SION ti.f,,.� Vl1,l-o;2-8 FE COPY Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not a1.1tfr,) a the violation of any adopted code or ordinance. Rocc'pt of a roved Field , . PP and co � � , . is acknowledged: By Date:. , - .20/ City Of Tukwila BUILDING DIVISION MRoZ8 EGrty c1n R OF LA FEB 2 3 2012 PERMIT CENTER ALL INFORMATION ON THIS pgCUMENT IS THE EXCLUSIVE PROPERTY OF PACIFIC ENGINEERING TECHNOLOGIES, INC. © COPYRIGHT 2012 O od Y d r N 2 i 1 a a Z• CD cu 0 Q) • CD . Y 5 O Q) N N 3 r VO)coM r - N N cc a I4S2S - MILITARY ROAD S. Job No. 1124 ra. 2/14/2012 11243.wd.A2.dwg NEW PREMANUFACTURED ROOF TRUSSES REFER TO STRUCTURAL 5' -0" MIN. CLEAR 1 AD2 ROOF PLAN eN SCALE: 1/8" = 1' -0" EXIST. FINISHES t0 REMAIN (NO WORK) BATHROOM EXHAUST FANS TO PENETRATE CEILING. FILL ANNULAR SPACE AROUND PENETRATION PER SECTION DUCTS TO EXTEND TO ROOF PENETRATION AT ROOF SHEATHING ADI NEW ATTIC DRAFT STOP IN ACCORDANCE WITH IBC SECTIONS 1113.1 AND 111.42. LOCATE ABOVE INTERFACE BETWEEN UNITS 204/205 AND 206/201. USE 5/8" TYPE 'X' GLOB WITH ALL JOINTS BACKED AND PENETRATIONS SEALED. REF. SECTION AD2 FINISHES TO BE REMOVED AND REPLACED PROVIDE (2) LAYERS OF 5/8" TYPE 'X' GYPSUM SHEATHING AT UNDERSIDE OF SOFFIT, (SHOWN MI =), REF. SECTION 3 AD2 ROOF PENETRATIONS FOR EXHAUST FANS MUST BE A MINIMUM OF 5' -0" FROM EXTERIOR WALL 3 AD2 APPROX. LOCATION OF BATHROOM EXHAUST FAN PATH AT FIRST FLOOR, REF. SECTION ADI BATHROOM EXHAUST DUCT IS APPROX. 4 "4'. CUT 2x10 FLOOR JOISTS UP t0 A MAXIMUM OF 4 1/2 ". IN THE CENTER 1/2 OF THE JOIST. LOCATE HOLES A MINIMUM OF 2' -6" FROM INTERIOR FACE OF EXTERIOR WALL t0 A MAXIMUM OF 3' -6" 4 AD1 AD1 APPROX. LOCATION OF RANGE HOOD EXHAUST FAN IN EA. UNIT PROVIDE (2) LAYERS OF 5/8" TYPE 'X' GYPSUM WALLBOARD AT CEILING FOR 1 -HOUR ROOF /CEILING ASSEMBLY, (SHOWN REF. SECTION FE WOOD DECK DN FE WOOD DECK DN FE WOOD DECK DN 2N1D FLOOR PLAN SCALE: 1/8" I' -0" EXIST. FINISHES TO REMAIN (NO WORK) RANGE HOOD EXHAUST FANS TO PENETRATE CEILING. FILL ANNULAR SPACE AROUND PENETRATION PER SECTION DUCTS TO EXTEND TO ROOF PENETRATION AT ROOF SHEATHING AD1 FINISHES TO BE REMOVED AND REPLACED T T 0- O 0, A 4111 •O's. I O . / N U, - L 00 / o 1/ EF o -0 �D - � 0- E13 � CD� Ir A1 =9 0 �l C13 ElD r ail V' J O X e �I O � 1 11 I 1 UNIT 205 UNIT 206 I I UNIT 201 , �� = (71 I I j I UNIT 203 UNIT 204 ± 11 I I I I I UNIT 108 . I � I UNIT 103 . i- 4 I EL 1 I / UNIT 105 UNIT 106 I ' UNIT 101 _ I 1 f . I o ,o ri .H o 1 __ H l 1 q do , i b d N O -' L /__ r .__- i �i . =l 2 AD I FE WOOD DECK DN FE WOOD DECK DN FE WOOD DECK DN 2N1D FLOOR PLAN SCALE: 1/8" I' -0" EXIST. FINISHES TO REMAIN (NO WORK) RANGE HOOD EXHAUST FANS TO PENETRATE CEILING. FILL ANNULAR SPACE AROUND PENETRATION PER SECTION DUCTS TO EXTEND TO ROOF PENETRATION AT ROOF SHEATHING AD1 FINISHES TO BE REMOVED AND REPLACED T T OHO . / N U, - 00 0- _0 =9 �l C13 ElD ail . O ' (71 O O N/ O O / 11 I I I I I UNIT 108 . I � I UNIT 103 UNI 104 , I 01 1 I I EL 1 I / UNIT 105 UNIT 106 I ' UNIT 101 _ I 1 u 0 4 ri I, 1 l 1 do i b q 111 ob i �i . =l 1r _7') cD I- N O -•a 0 2 API UP 0 UP FE UP 0 let FLOOR PLAN SCALE: I/8" = 1' -0" 0 2 AD2 BATHROOM EXHAUST FANS TO PENETRATE CEILING. FILL ANNULAR SPACE AROUND PENETRATION PER SECTION DUCTS TO BE ROUTED TO EXTEND TO ROOF PENETRATION AT ROOF SHEATHING A MINIMUM OF 5' FROM EXTERIOR WALL ADI RANGE HOOD EXHAUST FANS TO PENETRATE CEILING. FILL ANNULAR SPACE AROUND PENETRATION PER SECTION DUCTS TO BE ROUTED TO EXTEND TO ROOF PENETRATION AT ROOF SHEATHING A MINIMUM OF 5' FROM EXTERIOR WALL 1 ADI PROVIDE (2) LAYERS OF 5/8" TYPE 'X' GYPSUM WALLBOARD AT INTERIOR FACE OF EXTERIOR WALL, (SHOWN I I), REF. SECTION ADI PROVIDE (2) LAYERS OF 5/8" TYPE 'X' GYPSUM WALLBOARD AT INTERIOR FACE OF EXTERIOR WALL, (SHOWN I I), REF. SECTION 2 ADI LEI PENETR4TION THROUGH WALL SHALL BE, 3' -0" MIN. FROM OPERABLE OPENING. PANTRY 3 AD1 KITCHEN II PROVIDE CLOSET SHELF AND ROD BEDROOM CHASE FOR DUCTS AT 2ND FLOOR REF. SECTION 4 AD2 PINING ROOM APPROX. LOCATION OF KITCHEN RANGE HOOD EXHAUST FAN PATH AT FIRST FLOOR, REF. SECTION 1 AD1 I- I VING ROOM 5 AD1 TIP. ENLARGE 1-5EDROOM UNIT FLOOR PLAN 1 SCALE: 1/4" = l'-0" LEGEND LJ EF RH FE PROVIDE 22 "x30" LOCKABLE ATTIC ACCESS IN ACCORDANCE WITH IBC SECTION 12092 AT SECOND FLOOR CEILING CARBON MONOXIDE DETECTOR NEW HARD WIRED SMOKE DETECTOR SMOKE DETECTORS WITHIN UNIT SHALL BE INTERCONNECTED EXHAUST FAN. REF. SECTION RANGE HOOD REF. SECTION 1 ADI ADI 140T WATER TANK FIRE EXTINGUISHER CABINET NEW EXTERIOR /INTERIOR DOOR EXISTING EXTERIOR/INTERIOR DOOR TO REMAIN NEW VINYL WINDOW EXISTING WINDOW TO REMAIN REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 2 2012 City of Tukwila BUILDING DIVISION MOZ8 CAF TIIKYNLh FEB 2 2012 PERMIT CENTER ALL INFORMATION ON THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF PACIFIC ENGINEERING TECHNOLOGIES, INS; © COPYRIGHT 2012 0 a N c o Q; 8 iV U r 2 0. Y 3 N. a 14828 - MILITARY ROAD S Job. No. 11243.00 ;te' \9tQVJ SECTION NO SCALE AT EXHAUST FAN RECESSED LIGHTING FIXTURE BEARING U.L. LISTINGMARK EXIST. PLYWOOD SHEATHING NEW LAYER 1/2" TYPE 'X' GUS WRAP AT HORIZONTAL DUCT ENCLOSURE BATHROOM OR KITCHEN EXHAUST FAN OR HOOD DUCT BEYOND NEW LAYER 1/2" TYPE 'X' GYPSUM WALLBOARD OVER RESILIENT CHANNELS NOTE: PENETRATIONS BY DUCTS AT THE FLOOR /CEILING AND ROOF /CEILING MEMBRANE SHALL HAVE THE ANNULAR SPACE AROUND THE PENETRATION FILLED WITH A MATERIAL TESTED BY ASTM E 119 OR UL 263 IN ACCORDANCE WITH SECTION 113.4.1.1 EXCEPTION I 1/2" TYPE 'X' GWB DUCT LINING, TYP. 6" MIN. SOUND ATTENUATION BLANKETS RESILIENT CHANNEL AT 2nd FLOOR. EXIST. FLOOR JOISTS (1) LAYERS 1/2" TYPE 'X' GWB RECESSED LIGHTING PERP. TO FUR. TRUSSES S SCALE: 3" : l' -0" IN RATED FLOOR CEILING ASSEMBLY GA FILE No. FC5240 1 -14OUR NEW WALL CONSTRUCTION IN ACCORDANCE WITH GA FILE NO. WP 3660 OF THE GYPSUM ASSOCIATION SOUND ATTENUATION INSULATION EXIST. 2x8 WOOD PLATE NEW LAYER OF 5/8" TYPE 'X' GWB EA. SIDE NEW FLOOR CONSTRUCTION IN ACCORDANCE WITH GA FILE NO. FC 5240 OF THE GYPSUM ASSOCIATION INSTALLATION NOTES: ONE LAYER 5/8" TYPE 'X' GYPSUM WALLBOARD OR WATER RESISTANT AT BATH APPLIED At RIGHT ANGLES TO EACH SIDE OF 2x8 WOOD STUDS 16" O.G. WITH 2 1/4" TYPE S OR W DRYWALL SCREWS 1" O.C. VERTICAL JOINTS STAGGERED 16" O.C, HORIZONTAL JOINTS STAGGERED 24" O.C. ON OPPOSITE SIDES. 5/8" TYPE 'X' WATER RESISTANT GWB FIBERGLASS TUB 4 SHOWER ENCLOSURE TYP. PARTY UJ,4LL 4 SCALE: 3" = 1' -0" 1 -1-1OUR ASSEMBLY AT PLUMBING WALLS 2x4 STUD WALL W/ 1/2" GYPSUM WALLBOARD EACH SIDE TYP. INTERIOR 4RT I T I ON SCALE: 3" : 1' -0" PLYWOOD FLOOR SHEATHING 5/8" TYPE 'X' GWB ON RESILIENT CHANNELS UJALL AT 5ATI-1 /5W- 1OUJER VAPOR RETARDER NOT ALLOWED UNDER WATER RESISTANT GUS. SOUND SEALANT, TYP. CONT. BLOCKING NOTE: BATH /SHOWER ENCLOSURE NOT PRESENT AT SIM. SECTION 6 SCALE: 1 1/2" : 1' -0" INSTALLATION NOTES: ONE LAYER 1/2" TYPE 'X' GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO RESILIENT FURRING CHANNELS 24" O.G. WITH I" TYPE S DRYWALL SCREWS 12" O.G. GYPSUM BOARD END JOINTS LOCATED MIDWAY BETWEEN CONTINUOUS CHANNELS AND ATTACHED TO ADITIONAL PEICES OF CHANNEL 54" LONG WITH SCREWS 12" O.G. RESILIENT FURRING CHANNELS APPLIED AT RIGHT ANGLES TO 2x10 WOOD JOISTS 16" O.C. WITH 1 1/4" TYPE W DRYWALL SCREWS. WOOD JOISTS SUPPORTING I" NOMINAL T 4 G WOOD SUBFLOOR AND I" NOMINAL WOOD FINISH FLOOR OR I9/32" PLYWOOD FINISHED FLOOR WITH LONG EDGES T 4 G AND 15/32" INTERIOR PLYWOOD WITH EXTERIOR GLUE SUBFLOOR PERPENDICULAR TO JOISTS WITH JOINTS STAGGERED. EXIST. PLYWOOD FLOOR SHEATHING NEW SOUND ATTENUATION BATT INSULATION EXIST. 2x FLOOR FRAMING NEW 1/2" TYPE 'X' GYPSUM WALLBOARD NEW RESILIENT CHANNELS TYP. UNIT FLOOR SECTION SCALE: 3" : 1' -0" GA FILE No. FC5240 I -HOUR NEW R -I5 BATT INSULATION WITH VAPOR RETARDER ON INTERIOR FACE INTERIOR (2) LAYERS OP 5/8" TYPE 'X' GYPSUM WALLBOARD AT EAST WALL. (1) LAYER OF 5/8" TYPE 'X' AT NORTH AND SOUTH WALLS EXIST. 2x FRAMING EXtERJO R EXIST. PLYWOOD SHEATHING EXIST. WOOD SIDING TYR EXTERIOR WALL SECTION 2 SCALE: 3" = 1' -0" NEW WALL CONSTRUCTION IN ACCORDANCE WITH GA FILE NO. WP 3380 OF THE GYPSUM ASSOCIATION PROVIDE FULL HEIGHT 5/8" TYPE 'X' GLUE EVERY 10' -0" MAX. ACROSS STUDS. TAPE AND MUD SEAMS (IBC 1112.2) SOUND ATTENUATION INSULATION EXIST. 2x6 WOOD PLATE NEW LAYER OF 5/8" TYPE 'X' GWB EA. SIDE REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 2 2012 City of Tukwila BUILDING DIVISION INSTALLATION NOTES: ONE LAYER 5/8" TYPE 'X' GYPSUM WALLBOARD OR WATER RESISTANT AT BATH APPLIED AT RIGHT ANGLES t0 EACH SIDE OF 2x4 WOOD STUDS 16" O.G. STAGGERED 8" O.C. ON 2x6 WOOD PLATES WITH 6d COATED NAILS, 1 1/8" LONG, 0.0915" SHANK, 1/4" HEADS, 1" O.C. JOINTS STAGGERED 24" ON OPPOSftE SIDES. HORIZONTAL BRACING REQUIRED REQUIRED AT MID - HEIGHT. (LOAD BEARING). TYP. PARTY WALL 3 SCALE: 3" = 1' -0" I -HOUR ASSEMBLY M12OZ9 CITY FEB 2 3 2012 PERMIT CENTER ALL INFORMATION ON THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF PACIFIC ENGINEERING TECHNOLOGIES, INC. 0 COPYRIGHT 2012 0 z di C A% 3 {(_ od O a Q °° • c L0 M Z„� Q - • C7) CD V) LC) CD iii N C'.1 000 NN CO 0 s .€ 'C d 0 65 c hip 0 cr) 0• I.� 0%. .44 5 O 0,,-I a hi) cu 0 c 0 U 14&28 - MILITARY ROAD S V) Job 11243.00 NEW R -49 INSULATION WITH VAPOR PROVIDE BAFFLES AT EAVE. (2) LAYER OF 5/8" TYPE 'X' GWB ROOF SOFP SCALE: 3" = 1' -0" IT 3 TYP. VEfist. VENT CI-ASE 4 SCALE: 3" = 1' -0" (2) LAYERS OF 5/8" TYPE 'X' GLUM ATTACH PER SECTION 2 WOOD SOFFIT BOARD TO MATCH EXIST. PROVIDE WOOD TRIM AT TRANSITION FROM 1-HR CONSTRUCTION TO NON -RATED SOFFIT AT CORNERS 2x8 STUD WALL W/ 5/8" TYPE 'X' GYPSUM WALLBOARD EACH SIDE DUCT BEYOND NEW LAYER 5/8" TYPE 'X' GWB WRAP at VERTICAL DUCT ENCLOSURE NEW KITCHEN EXHAUST DUCT. REFER t0 BUILDING PLAN FOR ROUTING 2x FASCIA TO MATCH EXIST. 5/8" TYPE 'X' GYPSUM WALLBOARD WITH ALL JOINTS BACKED BY FRAMING AND PENETRATIONS SEALED, EACH SIDE (1) LAYER OF 5/8" TYPE 'X' GLUE SOUND ATTENUATION INSULATION NEW PLYWOOD SHEATHING NEW PREMANUFACTURED TRUSSES EXIST. 2x CEILING JOISTS 3 ROOF SHEATHING NEW ROOF TRUSSES AD1 TYP. PARTY WALL AT TRUSSES SCALE: 3" 2x CEILING JOIST R -49 INSULATION NEW LAYER 5/8" TYPE 'X' GYPSUM WALLBOARD 2x WOOD FRAMED WALLS (I) LAYER OF 5/8" TYPE 'X' GWB 1 (2) LAYER OF 5/8" TYPE 'X' GWB REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 2 2012 City of Tukwila BUILDING DIVISION INSTALLATION NOTES: BASE LAYER 5/8" TYPE 'X' GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES t0 2x10 WOOD JOISTS 24" O.C. WITH 1 1/4" TYPE W OR 9 DRYWALL SCREWS 24" O.G. FACE LAYER 5/8" TYPE 'X' GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1 1/S" TYPE W OR S DRYWALL SCREWS 12" O.C. AT JOINTS AND INTERMEDIATE TRUSSES AND 1 1/2" TYPE G DRYWALL SCREWS 12" O.C. PLACED 2" BACK ON EITHER SIDE OF END JOINTS. JOINTS OFFSET 24" FROM BASE LAYER JOINTS. WOOD TRUSSES SUPPORTING 1/2" PLYWOOD WITH EXTERIOR GLUE APPLIED AT RIGHT ANGLES TO TRUSSES WITH SD NAILS. APPROPRIATE ROOF COVERING. CEILING PROVIDES ONE HOUR FIRE RESISTANCE PROTECTION FOR FRAMING, INCLUDING TRUSSES. (CE ILI14 AT UNIT 208 ONLY) iTciiLIwG ASSEMBLY 2 (GYPSUM ASSOC. 'RC2601) CITY SCAS/1tA FEB 2 3 2012 PERMIT CENTER ALL INFORMATION ON THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF PACIFIC ENGINEERING TECHNOLOIES, INC. 0 COPYRIGHT 2012 6 N c 0 ° O Q S^ 0 CD p 0 N 1 1 0000N N N (0 CO CO 0 N N 00 4) 4) N c = o 2.E cm_ U .2 ��o b 0 cr, CJ's .,E'.), tc%c •- W O 0 o..4 q CIO ail ttO 1)i 0 W