HomeMy WebLinkAboutPermit M12-036 - BED BATH & BEYONDBED BATH & BEYOND 400 STRANDER BL M12 -036 City oftukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0223100070 Address: 400 STRANDER BL TUKW Project Name: BED BATH & BEYOND Permit Number: M12 -036 Issue Date: 04/09/2012 Permit Expires On: 10/06/2012 Owner: Name: GARFIELD - SOUTHCENTER L L C Address: 388 PEARL ST , EUGENE OR 97401 Contact Person: Name: ANDI VAN BLARICOM Address: 5005 THIRD AV S , SEATTLE WA 98134 Email: ANDIV @MCKINSTRY.COM Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA 98124 Contractor License No: MCKINCL942DW Phone: 206 - 832 -8315 Phone: 206 762 -3311 Expiration Date: 03/16/2014 DESCRIPTION OF WORK: REPLACE 12 LENNOX GAS PACK UNITS WITH "LIKE FOR LIKE" REPLACEMENTS. WE WILL BE ADDING NEW DISCONNECTS AND CURB ADAPTORS. SEE "SCOPE OF WORK" ATTACHMENT FOR MORE DETAILS Value of Mechanical: $26,122.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read an governing this work will be compli exa d wit Fees Collected: $514.31 International Mechanical Code Edition: 2009 Date: (H I L 1- ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not p -s e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Date: G` /120)2 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -036 Printed: 04 -09 -2012 PERMIT CONDITIONS Permit No. M12-036 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The fire alarm system for Bed Bath & Beyond needs to be independent of REI. Currently the two systems are inter - connected. The fire alarm system in the Bed Bath & Beyond space needs to have its own fire alarm control panel. 15: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 16: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an'automatic shutoff. Automatic shutoff shall be accomplished; by interrupting the power source of the air - moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be.installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) : , 17: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 18: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 19: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC doc: IMC -4/10 M12 -036 Printed: 04 -09 -2012 104.2) • • 21: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 22: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M12 -036 Printed: 04 -09 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Nt I .,3 Project No.. Date Application Accepted --1 Date ApplicationExpires: 9 -4 - ( ; (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION J ` King Co Assessor's Tax No.: Vaa D 1 C) Site Address: H t7 O rker Z \�i(2 Suite Number: Tenant Name: )9C `. -EeLtCYY4 ?fl \ PROPERTY OWNER Company Name: ,rtes' \n ` ' ` 1 Name: Gie`d1p,\e,. ,mot„ .. 1 ` / �1 JU1 Address: 5' ` D . `z1 \\�Iv' et Jur City: Tw ;\ 0 State: uLs cA Zip: g B i b CONTACT PERSON — person receiving all project Communication Company Name: ,rtes' \n ` ' ` 1 Name: () „. _` '\ \ /` ;0,r; Address: syck Address: &) v City: ��l , State: w 1\0‘ Zip: Ca 13. Jzi ,Q City: State: Zip :C ( Phone: Zicto -ss3z SFax: ate: 3 Email: n ^ . ►', ,q@ fy\exici Yl-1 . czyy, New Tenant: Floor: ❑ Yes `A] ..No MECHANICAL CONTRACTOR INFORMATION Company Name: ,rtes' \n ` ' ` 1 n Address: syck e... City: ��l , State: w 1\0‘ Zip: Ca 13. Jzi ,Q Phone: o _\1(02— 331 x: Contr Reg No.:t_i e'�� `G,25, 12 . p ate: 3 I Its l ic Tukwila Business License No.: "6,..6 0 \LI ( 3 Valuation of project (contractor's bid price): $ 2.14 , t 22._ Describe the scope of work in detail: • Varj2, la, (-1-1V1CAL Oka% e,V- UX u 't U'c& kai t . t` )fefLacsaly l ,\-_ Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas Other: `a_ H:\Applicanons\Pomu- Applications On Line:2011 Applications\Mechanical Permit Application Revised 8.9 -1 l.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfrn Unit Type Qty Air handling unit >10,000 cfrn Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment qak cleat f c> I0 herufl►\S k2, u-n Boiler /Compressor ty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A THORIZED AGENT: Signature: lakVel l'_Y Print Name: f\ ntaT GL, Van i cur i L.t�YY� Mailing Address: O� 5 31 Date: 3) LP L 210 k Z Day Telephone: O IS-Z 1 City H:Wpplications\Forms- Applications On Line\2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh (SSA A 513Lf State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.ov Parcel No.: 0223100070 Address: 400 STRANDER BL TUKW Suite No: Applicant: BED BATH & BEYOND RECEIPT Permit Number: M12 -036 Status: APPROVED Applied Date: 03/09/2012 Issue Date: Receipt No.: R12 -01277 Payment Amount: $411.45 Initials: JEM Payment Date: 04/09/2012 12:39 PM User ID: 1165 Balance: $0.00 Payee: MCKINSTRY CO. SERVICE ACCOUNT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11976 411.45 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 411.45 Total: $411.45 doc: Receiot -06 Printed: 04 -09 -2012 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0223100070 Address: 400 STRANDER BL TUKW Suite No: Applicant: BED BATH & BEYOND RECEIPT Permit Number: M12 -036 Status: PENDING Applied Date: 03/09/2012 Issue Date: Receipt No.: R12 -01004 Payment Amount: $102.86 Initials: WER Payment Date: 03/09/2012 01:57 PM User ID: 1655 Balance: $411.45 Payee: MCKINSTRY CO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11943 102.86 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 102.86 Total: $102.86 doc: Receiot -06 Printed: 03 -09 -2012 INSPECTION /RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA::BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 ma- O?. Project: (N; 1' i eci $ P)f4du► =r Type of Inspection: '7---, s1/4iA Address: 460 a, � tL" Q F Date Called: Special Instructions: Date Wanted:. 1 1 -- {- 1 6,— a:m. p.m. Requester: r. Phone NO: d(o — e3 Z- J 3 I El-Approved per applicable codes. Corrections required prior to approval. COMMENTS: FP{ AA-,-t- IP ( i r■Io Date: fir% ri yiNSPECTION FEE )tEQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: d B 11111 9 1'1 —; tJ Address: b1) ....s-,-,T 1 1 „6 z__ Date Called: 5./i © / 5 1.0 77-4. '\.. Special Instructions: e4`%f1 0 6a3• 07 Date Wanted:. � �� a y p.m. Requester: e L +l ; C7-?1 Phone No: ..?0‘- 396- -/ 75 pproved per applicable codes. Corrections required prior to approval. COMMENTS: D p ` d B 11111 9 1'1 —; tJ dJV� Nlc'7 k.r, s % -C ',,,p,....) -,- N.NixrrJ . ..� 0 ciec.,,e ,1,,, -k 44...i - — Tom. ! -46c rj _ e L +l ; C7-?1 t i,m I — x 1 G 0. LLe( . nspectgt` Date: 12 -- I "— • ❑EINSI/3 CTION FEE REQUIRI . Prior to n xt inspection, fee must be paid t"6300 Southcenter Blvd.,)Suite 100., all to schedule reinspection. • 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /2 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: 6 c - 6 44-h aes GA 13 ,E lc.wld • Type of Inspection: ';1 4)42244-1 1c54". Address: yoo srP.'.Actr" 3,)va. Suite #: Contact Person: j'4-1'' ' G • Special Instructions: Phone No.: a,9 .71 Z- 3311 ✓Approved per apptc ble codes. Corrections required prior to approval. COMMENTS: 1 011, . fre ec/9'f,A, Nb 4✓027/ 4#4 o F4 ct° Kati 504...,Jle-- delir.--1-6 04 s . Fire Alarm: / Hood & Duct: Monitor: Pre Fire: Permits: Needs Shift Inspection: Grr) f3 Date: Sprinklers: Fire Alarm: / Hood & Duct: Monitor: Pre Fire: Permits: )17-,, ' ''Occupancy Type: Inspector: Grr) f3 Date: ./jZljz...,_ Hrs.: / _A_ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. ,C#11 19 schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 Form-FR-113 • r4 c REVIEWED FOR ODE COMPLIANCE APPROVED APR 092012 • City of Tukwila ILDING DIVISION • • r A T 1. • L • • tet z•-• 030 RECEIVED MAR 0 9 2012 PERMIT CENTER Bed Bath & Beyond #371 9/12/2011 Debba Hilnak Core States Group Bed Bath & Beyond #371 Tukwila, WA Thank you for the opportunity to provide this proposal for this project. EXISTING CONDITIONS: > Bed Bath & Beyond is looking to replace the (12) HVAC units currently serving the store. The current units are all Lennox units with the majority being 7.5 single stage units. There three (3) smaller units also serving areas of the store. All the units are gas heat package units. RECOMMENDATION: > We recommend removing and replacing the units in (2) stages and replacing (6) units in each stage. This will allow the store to continue to have some air flow during the replacement, allowing majority of the work to be completed on regular time. SCOPE OF WORK > Remove and dispose of existing equipment in an EPA approved manner > Provide Crane to lift the unit onto the roof of the building > Install customer provided adaptor curbs and new Lennox equipment > Provide miscellaneous materials such as, new gas and condensate piping (if needed) > Re -pipe new units to gas lines > Evacuate /charge and start-up units > Hook up and verify operations of Prodigy boards > Verify proper operation upon completion > Clean Job Site > Provide project management > Provide all mechanical and electrical permitting o This includes any cad drawing and engineering requirements for the city of Tukwila STANDARD EXCLUSIONS: Equipment and curbs (customer provided), deficiencies or failed parts found while performing scope, cut and patch of roofing, new disconnects (provided on equipment by customer), all electrical, load calculations and major engineering, any structural changes to the building, temporary cooling and any other work or materials not specified. CLARIFICATION: McKinstry will provide the permit, but the invoice to Bed Bath & Beyond for the permit will be separate from the quote and is not included in the price below. The permit price will be provided once we can determine the cost from the city. COST FOR THE ABOVE SCOPE Budget for above scope (including sales tax) $ 28,603.59 Payment is due in full upon substantial completion. This proposal is valid for 45 days from the date proposed. Upon your favorable review, please sign and return this proposal for scheduling and implementation. Should you have any questions or require additional information, please feel free to call me at 206 - 396 -1979. RECEIVED M (;i... 0 3 / MAR 09 2012 �� PERMITCENTER act SPECIFICATIONS GCS 16 -1353 & GCS 16 -1603 Sound RaLng Number m accordance with ARI Standard 270. Rated in accordance with ARI Standard 210/240 or 360; 95 °F outdoor air temperature and 80• db /67"F wb entering evaporator air, RECEIVED "For LPG units a field conversion kit is required and must be ordered extra. See Optional Accessories table. " "Using total airvolume and system static pressure requirements determine from blower performance tables rpm and bhp required. Maximum usable hp of motors furnished by Lennox are shown. If motors of comparable hp are used, be sure to keep within the service factor limitations outlined on )y��to rrY ekiAt M« -03 PERMIT CENTER Model No. GCS16 -1353 GCS16 -1603 "ARI Standard 210/240 Ratings or Standard *360 Ratings Total cooling capacity (btuh) 119,000 *142,000 Total unit watts 13,220 16,820 EER (Btuh/Watts) FILE 0 C© 8.50 Integrated Part Load Value'"r" '' - - - - 8.8 *ARI Standard 270 SRN (Bets) eek* rq.� g 8 Refrigerant (22) Charge – Stage 1 " 7 lbs. 4 oz. 10 lbs. 12 oz, Stage 2 ^ .- _ . 7 lbs. 4 oz. 7 lbs. 12 oz. Evaporator Blower and Drive Selection Blower wheel nominal diameter x width (in.) 15 x 15 15 x 15 Factory Installed ""Drives Nominal motor horsepower 2 3 Maximum usable horsepower 2.30 3.45 Voltage & phase 208/230/460v -3ph 208/230/460v -3ph RPM range 730 — 950 730 — 950 Optional Factory Installed Drives Nominal motor horsepower 3 - - - - Maximum usable horsepower 3.45 - - - - Voltage & phase 208/230/460v -3ph - - - - RPM range 730 -950 - - - - Evaporator Net face area (sq. ft.) 9.46 11.9 Tube diameter (in.) & No. of rows 3/8 — 4 3/8 — 3 Fins per inch 12 12 Condenser Coil Net face area (sq. ft.) 20.0 24.4 Tube diameter (in.) & No. of rows 3/8 — 2 3/8 — 2 Fins per inch 20 20 Condenser Diameter (in.) & No. of blades (2) 20 - 5 (2) 22 — 4 Air volume (cfm) 6400 Total 7700 Total Fans Motor.horsepower (2) 1/3 (2) 1/2 Motor watts 875 Total 1050 Total Btuh Input (low) 170,000 170,000 Two Stage Btuh Output (low) 132,500 132,500 Heating Capacity (Natural Gas Only) Btuh Input (High) 270,000 270,000 i�nn�r-- REVIEWED Btuh Output (High) F CODE COMPLIA.'+ICE R 216,000 216,000 A.G.A. Thermal Effi iency p APP ROVED 80% 80% Btuh Input (low) 170,000 170,000 Two Stage Btuh Output (low) APR 0 n 2012 APR 7 132,500 132,500 Heating Capacity ("LPG Gas Only) Btuh Input (High) 236,250 236,250 Btuh Output (High 192,500 192,500 A.G.A. Thermal E ciencyCIty ofTukwil- c. 81.5% 81.5% Gas Supply Natural BUILDING DIVIS'ON 3/4 3/4 Connections fpt (in.) * *LPG 3/4 3/4 Recommended Gas Natural 7 Supply Pressure (wc. in.) * *LPG 11 11 4 Condensate drain size mpt (in.) 1 1 No. &size of filters (in.) (4) 16 x 25 x 2 (4) 20 x 25 x 2 Net weight of basic unit (lbs.) (1 Package) 1100 1288 Electrical characteristics 208/230v or 460v — 60 hertz — 3 phase Sound RaLng Number m accordance with ARI Standard 270. Rated in accordance with ARI Standard 210/240 or 360; 95 °F outdoor air temperature and 80• db /67"F wb entering evaporator air, RECEIVED "For LPG units a field conversion kit is required and must be ordered extra. See Optional Accessories table. " "Using total airvolume and system static pressure requirements determine from blower performance tables rpm and bhp required. Maximum usable hp of motors furnished by Lennox are shown. If motors of comparable hp are used, be sure to keep within the service factor limitations outlined on )y��to rrY ekiAt M« -03 PERMIT CENTER • SPECIFICATIONS — GCS24- 813 -78 Model No. GCS24- 813 -78 Belt Drive Cooling Ratings Gross cooling capacity — Btuh (kW) 76,000 (22.3) *Net cooling capacity — Btuh (kW) 73,000 (21.4) *Total unit watts 7680 *EER (BtuhA'Vatt) 9.5 *ARI Standard 270 Sound Rating Number (bels) 8.6 Heating Ratings Sea Level One Stage Heating Capacity (Natural Gas) Input/Output — Btuh (kW) 78,000 (22.9) / 62,400 (18.3) A.G.A. /C.G.A. Thermal Efficiency / AFUE 80.0 % / 78.0% Sea Level One Stage Heating Capacity (*LPG) Input/Output — Btuh (kW) 78,000 (22.9) / 62,400 (18.3) A. G.A. /C.G.A. Thermal Efficiency / AFUE 80.0 % / 78.0% Refrigerant (HCFC -22) Charge — Lbs (kg) 10 lbs. 0 oz. (4.54) Evaporator Blower and Drive Selection Blower wheel nom. diameter x width — in. (mm) 12 x 12 (305 x 305) * *Factory Installed Drives Nominal motor horsepower (W) 1.5 (1120) Max. usable horsepower (W) 1.72 (1280) Voltage & phase 208/230/460v or 575v -3ph RPM range 835 — 1135 Evaporator Coil Net face area — sq. ft. (m2) 6.25 (0.58) Tube diameter — in. (mm) & No. of rows 3/8 (9.5) — 3 Fins per inch (m) 14 (551) Expansion device type Thermostatic Expansion Valve Drain connection (No. & size) — in. (mm) type (1) 3/4 (19) Condenser Coil Net face area — sq. ft. (m2) 12.9 (1.20) Tube diameter — in.(mm) & No. of rows 3/8 (9.5) — 2 Fins per inch (m) 20 (787) Condenser Fan (No.) Diameter — in.(mm) & No. of blades (1) 24 (610) — 4 Air volume — cfm (Us) 4500 (2125) Motor horsepower (W) 1/2 (373) Motor rpm 1075 Motor watts 500 Gas Supply Connections fpt — in. (mm) Natural Gas or •LPG 1/2 (12.7) Recommended Gas Supply Pressure — wc. in. (kPa) Natural Gas 7 (1,7) •LPG 11 (2.7) Filters Type of filter Pleated Disposable (furnished) No. & size — in. (mm) (4) 12 x 24 x 2 (305 x 610 x 51) Net weight of basic unit — lbs. (kg) 734 (333) Shipping weight of basic unit — lbs. (kg) (1 Package) 834 (378) Electrical characteristics 208/230/460v or 575v -3ph * Sound Rating Number in accordance with ARI Standard 270. * Rated in accordance with ARI Standard 210/240; 95 °F (35 °C) outdoor air temperature and 80 °F (27 °C) db /67 °F (19 °C) wb entering evaporator air. NOTE — ARI capacity is net and includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. **Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. In Canada, nominal motor output is also maximum usable motor output. •For LPG units a field installed kit is required and must be ordered extra. See Optional Accessories table. Page 4 WEIGHT. DATA — ALL MODELS:._' Description Weight Model No. lbs. I kg Net Weights LCA036S /H Net weight (Base unit) 645 292 LCA042S /H Net weight (Base unit) 645 292 LCA048S /H Net weight (Base unit) 675 306 LCA060S /H Net weight (Base unit) 685 6310 LCA060H Net weight (Base unit) 685 310 LCA072S Net weight (Base unit) 676 307 LCA072H Net weight (Base unit) 686 311 LGA036S /H Net weight (Base unit with low fire heat exchanger) 656 298 LGA042S /H Net weight (Base unit with low fire heat exchanger) 656 298 LGA048S /H Net weight (Base unit with low fire heat exchanger) 720 327 LGA060S /H Net weight (Base unit with low fire heat exchanger) 730 331 LGA072S Net weight (Base unit with low fire heat exchanger) 745 338 LGA072H Net weight (Base unit with low fire heat exchanger) 755 342 Shipping Weights (Add Factory Installed Options Weights To Base Unit Weights For Total Shipping Weight) LCA036S /H Base unit 775 351 LCA042S /H Base unit 775 351 LCA048S /H Base unit 805 365 LCA060S /H Base unit 815 370 LCA072S Base unit 806 366 LCA072H Base unit 816 370 LCA Models Only Electric Heat (add to Base unit) See Electric Heat Rating Tables LGA036S /H Base unit with low fire heat exchanger 786 357 LGA042S /H Base unit with low fire heat exchanger 786 357 LGA048S /H Base unit with low fire heat exchanger 850 386 LGA060S /H Base unit with low fire heat exchanger 860 390 LGA072S Base unit with low fire heat exchanger 875 397 LGA072H Base unit with low fire heat exchanger 885 401 LGA042, 048, 060 and 072 Models Only Dual /High Fire Heat Exchanger (add to Base unit) 18 8 All Models Economizer (add to Base unit) 56 25 Outdoor Air Damper (add to Base unit) 46 21 LTL Packaging (less than truck load) (add to Base unit) 13 6 Gravity Exhaust Dampers 8 4 Hood for Gravity Exhaust Dampers 15 7 HIGH ALTITUDE DERATE(LGA MODELS) A.G.A. certified units must be derated when installed at an elevation of more than 2000 feet (610 m) above sea level. If unit is installed at an alti- tude higher than 2000 feet (610 m), the unit must be derated 4% for every 1000 feet (305 m) above sea level. Thus, at an altitude of4000 feet (1210 m), the unit would require a derate of 16 %. C.G.A. certified units must be derated when installed at an elevation of more than 2000 feet (610 m) above sea level. If unit is installed at an alti- tude higher than 2000 feet (610 m), the unit must be derated 10% for elevations between 2000 feet and 4500 feet (610 m and 1370 m) above sea level. NOTE — This is the only permissible derate for these units. L Series036 -072/ Page 13 • • LENNOX TM Product Submittal PROJECT INFORMATION FILE COPY Permit No,— Project Name: Bed Bath & Beyond #371 Project Number: 3000210101 Project Location: TUKWILA, WA Project Altitude: 1000 CUSTOMER INFORMATION Company Name: Bed Bath & Beyond Company Address: 650 Liberty Ave Company Location:Union, NJ 07083 Contact: Phone: 908 - 688 -0888 ENGINEER INFORMATION REVIEWED FOR CODE COMPLIANCE APPROVED APR 09 2012 City of BUILDING DIVISION Company Name: Company Address: Company Location: , Contact: Phone: RECEIVED C)\c, - DJ\ov. Vag '&1-0Wm) ea1 09 PERMIT CENTER We are pleased to provide the attached project submittal. If you have any questions or need additional information, please feel free to call our office. M I 03b • Project #:3000210101 Project Name:Bed Bath & Beyond #371 Last Changed:TINA J. HANEY Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Prepared On:05/09/2011 Page: 1 of 18 Phone :908- 688 -0888 Lennox Industries Inc. - Product Submittal Table of Contents System ID Qty Model Description H0001. -'7, 9, 11 9 LGH120H4B PKGGE /10TON /CONFIGURABLE„ H0008 & 10 2 LGH072H4B PKGGE/6TON/CONFIGURABLE H00012 1 : LGH060H4E. • PKGGE /5TON /CONFIGURABLE ,;;' Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 2 of 18 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908- 688 -0888 • Lennox Industries Inc. - Product Submittal System ID: H0001 - 7, 9, 11 Package Model:LGH120H4B Description: PKGGE /10TON /CONFIGURABLE HEATING PERFORMANCE Heat Source H/E LowInput H/E LowOutput H/E HighInput H/E HighOutput System HeatOutput Natural Gas 156000 (Btuh) 125000 (Bruh) 240000 (Btuh) 192000 (Btuh) 192000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.75 (in.) 44.4 ( °F) 80 2 11 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R-410A 12.0 12.7 9900 (W) 122000 (Btuh) 118000 (Btuh) 124400 (Btuh) 116930 (Btuh) 89568 (Btuh) 82098 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 58.0 ( °F) 56.6 ( °F) 59.8 ( °F) 57.3 ( °F) 32.8 (lb/hr) 32.8 (lb/hr) FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 4000 (cfm) 4000 (cfrn) 0.80 (in.WC) 2.50 (hp) 3.00 (hp) CAV Belt Drive 1000 (rpm) 940 (rpm) 1200 (rpm) TotalStaticPress Wet Coil Static Press Gas H/E Static Press Economizer Static Press Air Filter Qry Air Filter Length Air Filter Width Air Filter Thickness Number Exhaust Fans ExhaustFan NomPower 1.52 (in.WC) 0.31 (in.WC) 0.22 (in.WC) 0.19 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) 1 0.3 (hp) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA System FLA DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight SOUND 460V 3Ph 60 (Hz) 27.0 (amp) 30 (amp) 16.0 (amp) 24.7 (amp) SupplyFan FLA CondensingUnit FLA CondenserFan Power Unit Oper Range 4.8 (amp) 2.6 (amp) 725 (W) +1- 10% Nominal Voltage 60.1 (in.) 101.3 (in.) 46.9 (in.) 1376 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 24.0 (in.) 27.0 (in.) Outdoor Sound Rating 88 (db) •Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 3 of 18 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908-688-0888 Lennox Industries Inc. - Product Submittal System ID:H0001 - 7, 9, 11 Package Model:LGH120H4B Description: PKGGE /10TON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on all other components of I year See Limited Warranty Certificate included with unit for details Limited warranty on aluminized heat exchanger of 10 years Limited warranty on Prodigy Unit Controller of 3 years INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GLOBAL ECONOMIZER STD STATIC PEF 2 IN MERV4 FILTER STANDARD CAP RA SMOKE DETECTOR NOVAR ETM -2051 GFCI - FACTORY INSTALLED/FIELD WIRED BY ELECTRICIAN DISCONNECT • INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 55W07 EIGARDIOB -1 HAIL GUARD E3126 NAWTY - EXTRA YR COMP PARTS -10T E3148 NAWTY - EXTRA YR COMP LABOR-10T E3I04 NAWTY - EXTRA YR PARTS - 10T E3082 NAWTY - EXTRA YR LABOR - 10T • Project #:3000210101 Quote #:4000249244 Page: 4 of 18 Project Name:Bed Bath & Beyond #371 Quote Desc:Bed Bath & Beyond #371 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908- 688 -0888 Lennox Industries Inc. - Product Submittal System ID:H0001 - 7, 9, 11 Package Mode1:LGH120H4B Description: PKGGE /1OTON /CONFIGURABLE DIMENSIONS - INCHES (MM) Model No. CORNER WEIGHTS CENTER OF GRAVITY AA BB CC DD EE FF Base Max. Base Max. Base Max. Base Max. Base Max. Base Max. Ibs. kg Ibs. kg Ibs. kg Ibs. kg Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm in. mm in. mm 092 293 133 338 153 263 119 295 134 286 130 316 143 326 148 370 168 46.5 1181 45.5 1156 24.5 622 25.5 648 102 294 134 340 154 265 120 297 135 288 131 318 144 328 149 372 169 46.5 1181 45.5 1156 24.5 622 25.5 648 120 306 139 349 158 275 125 305 138 295 134 326 148 334 152 382 173 46.5 1181 45.5 1156 24.5 622 25.5 648 150 316 143 359 163 284 129 314 142 304 138 152 393 345 157 393 178 46.5 1181 45.5 1156 24.5 622 25.5 648 ase Unit - The unit with NO OPTION Max. Unit - The unit with ALL OP11ONS Installed. (Economizer. etc.) 58-16 (1476) 100 f� O 001 43 318 (1102) J 60-1.6 a 3-112 (1527) (89) END VIEW 6.1/'8 5.5:B (156) (143) BOTTOM SUPPLY /AIR OPENING fi•v'8_� (156) 60-1/8 (1527) BASE BOTTOM POWER ENTRY 5-1/2 (140) Do. 24 10.3.41 28 (610) (273) 20 (711) (508) 27 (686) BOTTOM RETURN AIR EE NI� -t-- CENTER OF */ GRAVITY S ,. +.1 6.5:8 \ Fj F 7 (178) 't' (168) 7 DD I ' + BOTTOM f 7(178) CONDENSATE ,y_ 34- 718_x, (886) 101 -1/4 BASE (2572) TOP VIEW 99 -114 OPTONAL DISCONNECT (2521) (FACTORY INSTALLED) BB CC ELECTRIC INLETS 15 -1/2 (394) CONDENSATE GAS SUPPLY DRAIN (FRONT) / INLET SIS TT , (137) ,a-1 /2 I I (470) 9 (886)_r 39-7/6 (1013) FORKLIFT SLOTS (BOTH SIDES) LIFTING HOLES (FOR RIGGING) 00 46 718 (1191) 101 -114 (2572) SIDE VIEW 15 -1,2 (394) .dl JtIII 7111111 HORIZONTAL SUPPLY AIR OPENING HORIZONTAL RETURN AIR OPENING „r- 4 1 -S'8 (41) 30 (762) 00 00 12.118 (308) 6 -1/8 (156) 31 -1i2 —(800) 66-3/8 (1886) Project #:3000210101 Project Name:Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 5 of 18 CONDENSATE DRAIN (BACK) 30 (762) 5 -3/8 (137) SIDE VIEW (Horizontal Openings) Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908-688-0888 • • Lennox Industries Inc. - Product Submittal System ID:H0001 - 7, 9, 11 Package Model:LGH120H4B Description: PKGGE /1 OTON /CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL 21 -3/8 r OUTDOOR AIR HOOD (Furnished with Economizer or Outdoor Air Damper) EXHAUST AIR HOOD (Furnished. Feld Installed) (543) Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 6 of 18 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908-688-0888 I!III. �►` } 0 ee 0 1IliI 00] Ioo 0 0 Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 6 of 18 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908-688-0888 • • Lennox Industries Inc. - Product Submittal System ID:H0001 - 7, 9, 11 Package Model:LGH 120H4B Description: PKGGE /10TON /CONFIGURABLE UNIT CLEARANCES • INCHES (MM) t Unit Clearance A r,. C OPTIONAL OUTDOOR To Clearance in. mm AIR X000 mm _% mm in. mm , -� 60 A/ / , / / / /// JJ /ii / /� /// t Unit Clearance A 13 C To Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 60 1524 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable pars. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 7 of 18 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908- 688 -0888 • Lennox Industries Inc. - Product Submittal System ID:H0008 & 10 Package Model:LGH072H4B Description: PKGGE /6TON /CONFIGURABLE HEATING PERFORMANCE Heat Source H/E HighInput H/E HighOutput System HeatOutput Natural Gas 105000 (Btuh) 84000 (Btuh) 84000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 32.4 ( °F) 80 1 11 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI LEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R-410A 12.0 12.5 6000 (W) 73500 (Btuh) 72000 (Btuh) 77200 (Btuh) 73489 (Btuh) 57900 (Btuh) 54189 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 1 0.75 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 56.2 ( °F) 56.2 ( °F) 57.8 ( °F) 56.8 ( °F) 18.2 (lb/hr) 18.2 (lb/hr) FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 2400 (cfm) 2400 (cfm) 0.80 (in.WC) 1.16 (hp) 2.00 (hp) CAV Belt Drive 870 (rpm) 632 (rpm) 875 (rpm) TotalStaticPress Wet Coil Static Press Gas H/E Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 1.03 (in.WC) 0.13 (in.WC) 0.05 (in.WC) 0.05 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA System FLA 460V 3Ph 60 (Hz) 17.0 (amp) 25 (amp) 9.7 (amp) 14.5 (amp) SupplyFan FLA CondensingUnit FLA CondenserFan Power Unit Oper Range 3.4 (amp) 1.4 (amp) 410 (W) +/- 10% Nominal Voltage DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 46.9 (in.) 912 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 82 (db) Project #:3000210101 Quote #:4000249244 Page: 8 of 18 Project Name: Bed Bath & Beyond #371 Quote Desc:Bed Bath & Beyond #371 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908-688-0888 • Lennox Industries Inc. - Product Submittal System ID:H000S & 10 Package Model:LGH072H4B Description: PKGGE /6TON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details Limited warranty on aluminized heat exchanger of 10 years Limited warranty on Prodigy Unit Controller of 3 years INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GLOBAL ECONOMIZER BAROMETRIC RELIEF DAMPERS 2 IN MERV4 FILTER STANDARD CAP RA SMOKE DETECTOR NOVAR ETM-205 1 GFCI - FACTORY INSTALLED/FIELD WIRED DISCONNECT BY ELECTRICIAN • INCLUDED SYSTEM OPTIONS 17W90 E3123 E3145 E3101 E3079 • - FIELD INSTALLED TI GARD ION-1 HAIL GUARD 5/6T, T TALL NAWTY - EXTRA YR COMP PARTS -6T NAWTY - EXTRA YR COMP LABOR -6T NAWTY - EXTRA YR PARTS - 6T NAWTY - EXTRA YR LABOR - 6T Project #:3000210101 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 9 of 18 Project Name: Bed Bath & Beyond #371 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908-688-0888 • • • Lennox Industries Inc. - Product Submittal System ID:H0008 & 10 Package Model:LGH072H4B Description: PKGGE /6TON /CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF GG HH Ibs. kg Ibs. kg lbs. kg lbs. kg in. mm in. mm in. mm in. mm LGH036 Std. Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 29 737 46.75 1187 LGH036 Max. Unit 132 60 149 68 241 109 213 97 40 1016 18 457 29 737 45.25 1149 LGH048 Std. Unit 104 47 126 57 202 92 167 76 38.5 978 18 457 29 737 46.75 1187 LGH048 Max. Unit 140 64 158 72 255 116 225 102 40 1016 18 457 29 737 45.25 1149 LGH060 Std. Unit 118 54 144 65 232 105 191 87 38.5 978 18 457 29 737 46.75 1187 LGH060 Max. Unit 159 72 179 82 289 131 256 116 40 1016 18 457 29 737 45.25 1149 LGH072 Std. Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 29 737 46.75 1187 LGH072 Max. Unit 167 76 189 86 305 138 269 122 40 1016 18 457 29 737 45.25 1149 Std. Unit - The unit with NO OPTIONS. Max. Unit -The unit with ALL OPTIONS Installed. (Economizer, etc.) as (1143) t5) (25) 100 1 )001 47 (1192) BASE 11 END VIEW AA 7(78) 5.5/8 143 (279) 1(413) 18 (457) 29 (737) 47 (1192) 1 BASE 1 BOTTOM RE41TURRN OPENING BOTTOM,'" AIR OPENING CENTER OF GRAVITY 6 8� (1681 Ne 3-1 LIFTING HOLE (For rigging) DD I 26.1/2 (673) BOTTOM BOTTOM POWER ENTRY CONDENSATE OUTLET 3 X8 (76 X 203) TOP VIEW (Base) 5(102) t 20 (508) 9-1,2 (241) EE—� LI �� I , !HI ���� XIII I 1,1 I� (3 ) -(506) 11. 11111 —1-1 t /—( 1 FORKLIFT SLOTS HORIZONTAL HORIZONTAL (Front, Back and SUPPLY AIR 5-12 RETURNAIR 5-1/2 Bbwcr Eno) OPENING (140) OPENING (140) (Without Economizer) SIDE VIEW BB CC 1 (25) 11 r_19-172 (495) I ---41" 18-3(8 (467) _ (279) 1'2157) l00 Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 10 of 18 BACK VIEW Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908- 688 -0888 63114 (2115) CONDENSATE OUTLET (EITFER SIDE) \a FLUEVENT OUTLET\ iS ELECTRICAL / INLET GAS INLET 15(381) 1I 5-172 (140) '2(89) 00 1— • • 26-1/2 I 27 (673) --�� —III 85-1/4 4 )2165) (666) _JI LI �� I , !HI ���� XIII I 1,1 I� (3 ) -(506) 11. 11111 —1-1 t /—( 1 FORKLIFT SLOTS HORIZONTAL HORIZONTAL (Front, Back and SUPPLY AIR 5-12 RETURNAIR 5-1/2 Bbwcr Eno) OPENING (140) OPENING (140) (Without Economizer) SIDE VIEW BB CC 1 (25) 11 r_19-172 (495) I ---41" 18-3(8 (467) _ (279) 1'2157) l00 Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 10 of 18 BACK VIEW Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908- 688 -0888 • • • Lennox Industries Inc. - Product Submittal System ID:H0003 & 10 Package Model:LGH072H4B Description: PKGGE /6TON /CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) 11.3'4 293; 036 ihN O`-B 15.:/1 (a of ()FA dvo 071 OPTI011A_ OUTDOOR AIR H000 — (FUm31e0 nth Em M mil en — J o OPTIONPL BAROMETRIC REUEFI-ICOD Ft:m ithed with Econoni_cri OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) SIDE VIEW BAROMETRIC RELIEF H000 FOR ECONOMIZER (Furnished) 30 -1:'2 (775) Model A B C No. in. mm in. mm in- mm 036.046 19-1/4 489 13 330 11-3/4 298 060.072 23-1/4 591 17 432 15 -3/4 400 Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 11 of 18 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908-688-0888 • • Lennox Industries Inc. - Product Submittal System ID:H0008 & 10 Package Model:LGH072H4B Description: PKGGE /6TON /CONFIGURABLE UNIT CLEARANCES - INCHES (MM) OUTDOOR AIR HOOD ' Unit Clearance A f3 C To Clearance in. mm in. mm in. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the rrounting surface. ' Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 12 of 18 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908-688-0888 • • Lennox Industries Inc. - Product Submittal System ID: H00012 Package Model:LGH060H4E Description: PKGGE/5TON /CONFIGURABLE HEATING PERFORMANCE Heat Source H/E Highlnput WE HighOutput System HeatOutput Natural Gas 105000 (Btuh) 84000 (Btuh) 84000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 38.9 ( °F) 80 1 11 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R-410A 12.7 17.0 4700 (W) 61600 (Btuh) 60000 (Btuh) 63300 (Btuh) 60917 (Btuh) 47475 (Btuh) 45092 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 2 0.75 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 56.6 ( °F) 56.4 ( °F) 57.8 ( °F) 56.8 ( °F) 14.9 (lb/hr) 14.9 (lb/hr) FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM Motor Torque Pct 2000 (cfm) 2000 (cfm) 0.80 (in.WC) 1.00 (hp) 1.00 (hp) MSAV Direct Drive 1096 (rpm) 76 TotalStaticPress Wet Coil Static Press Gas H/E Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.99 (in.WC) 0.10 (in.WC) 0.04 (in.WC) 0.05 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA System FLA 460V 3Ph 60 (Hz) 18.0 (amp) 25 (amp) 9.0 (amp) 14.8 (amp) SupplyFan FLA CondensingUnit FLA Unit Oper Range 3.7 (amp) 2.1 (amp) +/- 10% Nominal Voltage DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 46.9 (in.) 835 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 82 (db) Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 13 of 18 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908-688-0888 • Lennox Industries Inc. - Product Submittal System ID:H00012 Package Model:LGH060H4E Description: PKGGE /5TON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details Limited warranty on aluminized heat exchanger of 10 years Limited warranty on Prodigy Unit Controller of 3 years LNCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GLOBAL ECONOMIZER BAROMETRIC RELIEF DAMPERS 2 IN MERV4 FILTER STANDARD CAP RA SMOKE DETECTOR NOVAR ETM -2051 GFCI - FACTORY INSTALLED/FIELD WIRED BY ELECTRICIAN DISCONNECT • INCLUDED SYSTEM OPTIONS - FIELD LSTALLED 17W90 TIGARDION -1 HAIL GUARD 5/6T, T TALL E3122 NAWTY - EXTRA YR COMP PARTS -5T E3144 NAWTY - EXTRA YR COMP LABOR -5T E3100 NAWTY - EXTRA YR PARTS - 5T E3078 NAWTY - EXTRA YR LABOR - 5T • Project #:3000210101 Quote #:4000249244 Page: 14 of 18 Project Name:Bed Bath & Beyond #371 Quote Desc:Bed Bath & Beyond #371 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908- 688 -0888 • • • Lennox Industries Inc. - Product Submittal System ID:H00012 Package Model:LGH060H4E Description: PKGGE/STON /CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA B8 CC DD EE FF GG HH Ibs. kg Ibs. kg lbs. kg lbs. kg in. mm in. mm in. mm in. mm LGH036 Std. Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 29 737 46.75 1187 LGH036 Max. Unit 132 60 149 68 241 109 213 97 40 1016 18 457 29 737 45.25 1149 LGH048 Std. Unit 104 47 126 57 202 92 167 76 38.5 978 18 457 29 737 46.75 1187 LGH048 Max. Unit 140 64 158 72 255 116 225 102 40 1016 18 457 29 737 45.25 1149 LGH060 Std. Unit 118 54 144 65 232 105 191 87 38.5 978 18 457 29 737 46.75 1187 LGH060 Max. Unit 159 72 179 82 289 131 256 116 40 1016 18 457 29 737 45.25 1149 LGH072 Std. Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 29 737 46.75 1187 LGH072 Max. Unit 167 76 189 86 305 138 269 122 40 1016 18 457 29 737 45.25 1149 td. Unit - The unit with NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (Economizer. etc.) 45 (1143) (1(25) IOU I I D CUI (� 47(1192)_ (((- -- BASE END VIEW 5.5/8 11 (143) (279) 16.1/4 18 (413) is (457) 5(102) 7 (178) 29 (737) 47 (1192) BASE S`. 2s 3.1 DD BOTTOM RETURN i AIR OPENING BOTTOM", AIR OPENING CENTER OF GRAVITY 6519 1 1168 26.1/2 (673) 20 (508) T FIF BOTTOM CONDENSATE OUTLET TOP VIEW (Base) BB _J 09-12 (241) CC EE BOTTOM POWER ENTRY 3 X 8 (76 X203) �(6 3) LIFTING HOLES � (673) (For rigging) 27 (68fi S t )� BBAS85) E SIDE VIEW 1 (25) 11 19-112 18.3/8 (279) 2(51) (495) (467) 11 'III IIIIII 11 1'1 III (737) it I ill) 11 II. III ICU �= 1 UC 1 FORKLIFT SLOTS HORIZONTAL 1 HORIZONTAL (Front, Back and SUPPLY AIR 540 RETURN AIR 5-1/2 Blower End) OPENING ( ) OPENING (140 Without Economizer) Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 15 of 18 BACK VIEW Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908- 688 -0888 01114 (2115) 5 ( r CONOENSATE �.LE (ET/ER SIDE) FLUE/VENT OUTLET \ e j ELECTRICAL INLET GAS INLET _ _ _ 15 (381) 5-112 (140) /2(89) OC 1 ■INII 1 GO �(6 3) LIFTING HOLES � (673) (For rigging) 27 (68fi S t )� BBAS85) E SIDE VIEW 1 (25) 11 19-112 18.3/8 (279) 2(51) (495) (467) 11 'III IIIIII 11 1'1 III (737) it I ill) 11 II. III ICU �= 1 UC 1 FORKLIFT SLOTS HORIZONTAL 1 HORIZONTAL (Front, Back and SUPPLY AIR 540 RETURN AIR 5-1/2 Blower End) OPENING ( ) OPENING (140 Without Economizer) Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 15 of 18 BACK VIEW Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908- 688 -0888 • • • Lennox Industries Inc. - Product Submittal System ID:H00012 Package Model:LGH060H4E Description: PKGGE /5TON /CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AlR H000 DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) 1 OPTIONAL OUTDOOR AIR H000 (Fumy -w va. h Emnorna en 12 GOi: OPTIONAL BAROMETRIC / RELIEF HCOD lFcmi;he6 wiN Eoorortuc&l OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) 1- II-3'412M; 036 0+v 04 15.301 011711 3 0th 072 SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Furnished) Model A c SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Furnished) Model A B C No. in. mm in. mm in. mm 036.048 19-1/4 489 13 330 11 -3/4 298 060.072 23-1/4 591 17 432 15 -3/4 400 Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 16 of 18 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908- 688 -0888 • • • Lennox Industries Inc. - Product Submittal System ID:H00012 Package Mode1:LGH060H4E Description: PKGGE /5TON /CONFIGURABLE UNIT CLEARANCES - INCHES (MM) ' Unit Clearance A B C Top Clearance in. mm in. mm in. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 17 of 18 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908- 688 -0888 Lennox Industries Inc. - Product Submittal • MISCELLANEOUS MATERIALS COMSD Third Party CURBS PLUS: (12) EXISTING LE Project #:3000210101 Project Name: Bed Bath & Beyond #371 Quote #:4000249244 Quote Desc:Bed Bath & Beyond #371 Page: 18 of 18 Last Changed:TINA J. HANEY Prepared On:05/09/2011 Phone :908- 688 -0888 • • • Drawing Date: 4 -6 -07 REV: 002 2 -10 -11 I Approved By: ho l(bv 04. a,.l M SHELL:18 GA PANS:18 GA CHANNELS:18 GA CLOSURES: 18 GA I TOP FLANGE DIM: 1 1/2' 1 1 1 1 Q N C 151/2" J r / • ifs N N w rn N m 00 4 3/8" co I I �/ / / / / / ` (p 00 rf5 rn _ O i i 1" 791/4" O.D. s[ 3" i 28 114" 19 1/8" 30 7/8" 1 12" / 1 J r — 3" �' 29 1/2" DRAWN BY.: SLW —/ ..,-- 15112' --//— 29 7/8" �– 29116" =3 4518" �� 1 9/16 NEW UNIT:LENNOX i 85/8 "BASE T /K- SERIES /LGH -LCH 024 -072 CURBS PLUS IN 1:,o TRANSITION -CURB SYSTEM 1200 Carline Rd. Confidential and propriety information of Curbs Plus, Inc. unauthorized use, disclosure, or reproduction Is expressly prohibited. Rossville, GA 30741 TAG PLATE: LX108LX6 Phone:(706) 858 -1188 / Fax: (706) 866 -2339 website: www.curbs - plus.com APPROXIMATE WEIGHT:146 LBS. OLD UNIT:LENNOX GCS 24W -413 L- SERIES 036 -072/C HA/GCS24- 653/813 ROLLS OF GASKET:2 TAG: ote: Design subject to change without notice. File Name: LX108LX6 -0 NEW LENNOX T -CLASS A BOX EXISTING LENNOX L- SERIES 036 -072 ©2003 Curbs Plus, Inc. • • • Drawing Date: 1 -29 -04 REV: 003 3 -9 -11 I Approved By: AK,x /v10.11 In a P / t(% SHELL:16 GA. PANS:18 GA. CHANNELS:18 GA. CLOSURES: 16 GA. TOP FLANGE DIM: 1 1/2" to , L M // 7,' 7 �/' //' //' / R/A 2 9116" / A / 6 � U) m a0 u, M - �iF:6 N fV / 93 3/4" O.D. / / 57 7/8" 34 7/8" / T JI �. �' QTY.:9 DRAWN BY.: SLW --- 251/4" 31 112" / 31 114° 29/16" 33/ s° NEW UNIT:LENNOX 93 314° BASE UT-SERIES 090- 150/K- SERIES /LGH -LCH 092 -150 CURBS PLUS, h�t�Co TRANSITION -CURB SYSTEM OLD UNIT:LENNOX 1200 Carline Rd. Confidential and propriety Information of Curbs Plus, Inc. unauthorized use, disclosure, or reproduction is expressly prohibited. GCS /CHA/CHP /GHP 16/16W/24 -1353 (120 -150) Roseville, GA 30741 TAG PLATE: LX9LX80 / LX296LX80 Phone:(706) 858 -1188 / Fax: (706) 866 -2339 ROLLS OF GASKET:1 website: www.curbs - plus.com APPROXIMATE WEIGHT:255 LBS.* TAG: Note: Design subject to change without notice. File Name: LX9LX80 NEW LENNOX L- SERIES 090 -150 EXISTING LENNOX GCS16 -1353 ©2003 Curbs Plus, Inc. engineering architecture project management construction management permitting development services CORE STATES MIENS GROUP STRUCTURAL NARRATIVE AND CALCULATIONS FOR HVAC ROOFTOP UNIT REPLACEMENTS 400 STRANDER BLVD. TUKWILA, WA 98188 SITE ID: Store #371 Prepared for: Bed Bath and Beyond 650 Liberty Avenue Union, NJ 07083 REVIEWED FOR CODE COMPLIANCE APPROVED APR 092012 City of Tukwila BUILDING DIVISION CORREC710N LTR #, L Prepared by: CoreStates Group 501 Office Center Dr, Suite 400, Fort Washington, PA 19034 March 30, 2012 — Core States Project # BBY -12825 RECEIVED APR 04 2012 PERMIT CENTER TABLE OF CONTENTS Section Number Page 1.0 OBJECTIVE 1 2.0 STANDARDS, LOADING, AND REFERENCES 1 3.0 ANALYSIS APPROACH AND ASSUMPTIONS 2 4.0 CALCULATIONS 2 5.0 CONCLUSIONS 2 APPENDIX A CALCULATIONS APPENDIX B SURVEY NOTES APPENDIX C PHOTOGRAPHS 1.0 OBJECTIVE The objective of this report is to qualify the existing structural members of the building ( "Structure ") located at 400 Strander Blvd, Tukwila, WA 98188 for the replacement of HVAC equipment with newer models. The existing Structure is a one story retail building where the structural system is comprised of wood decking supported by wood timber and glue laminated beams. The wood roof is supported on the interior of the building with wood columns, and by a masonry bearing wall at the exterior. The equipment replacement consists of the following: QTY Existing RTU Brand Tons Existing RTU Model # Existing Unit Weight New Lennox RTU Model New Lennox Weights Approx. Adapter Curb Weights Difference w/ Adapter Curb ( + / -) 9 Lennox 10 GCS1613532707G 1345 LGH120H 1210 255 (120) 2 Lennox 6 GCS248131301G 734 LGH072H 762 146 (174) 1 Lennox 5 LGA060HH1G 750 LGH060H 685 146 (81) The equipment is supported on the existing curb with an adaptor. This means that the equipment is supported by the same footprint on the roof as the previous equipment. CoreStates Group visited the site on June 9, 2011 to measure the structural members supporting the proposed installation where accessible. Notes from this site visit are presented in Appendix B, and pictures are presented in Appendix C. This analysis and report is based on this information. It was observed in the field that several of the members supporting the existing HVAC had excessive splitting, and that these members had been reinforced with a sistered joist. 2.0 STANDARDS, LOADINGS, AND REFERENCES The existing structure was analyzed for the following codes and standards: • 2009 International Building Code • Minimum Design Loads for Buildings and Other Structures ASCE/SEI 7 -05, American Society of Civil Engineers • National Design Standard Specification for Wood Construction 2005 Edition, American Forest and Paper Association The following Code - specified Toad combination was used to analyze the existing Structure: 1. 1.4D 2. 1.2D +1.6L +0.5S 3. 1.2D +1.6S +(F,L or 0.8W) 4. 1.2D +1.6W +F,L +0.5S 5. 1.2D +1.0E +F,L +F2S 6. 0.9D +1.0E Where: F1 = 0.5 for other live Toads F2 = 0.7 for roof configurations that do not shed snow off the structure 1 3.0 ANALYSIS APPROACH AND ASSUMPTIONS The analysis approach used in this report is founded on the premise that if the structural members of the existing Structure which will be used to support the proposed equipment are structurally adequate, per the aforementioned standards or increase in forces in these members is Tess than a Code - specified 5% of the design forces, then the new RTU units are acceptable for replacement. The roof members were assumed to be made of Douglas Fir Larch, Grade No. 1. 4.0 CALCULATIONS Calculations for this analysis are provided in Appendix A of this report. 5.0 CONCLUSIONS Based on an analysis of the existing building for applied dead, new equipment, snow, wind, and seismic loads, the Structure does have adequate strength to support the new HVAC equipment. When loaded with the Code - Specified load combinations listed above, it was determined that the wood joists and beams had adequate capacity for the new units listed above, and that the proposed installation will not increase the existing gravity or lateral loads on the existing members more than 5 %. Therefore, the proposed installation may be undertaken as stated above. It has been assumed that all members supporting the equipment are in good condition structurally. If any of the members supporting the proposed equipment are seen to be in poor repair, then CoreStates Group should be notified. The conclusions reached by CoreStates Group in this report are only applicable for the previously mentioned existing structural members supporting proposed HVAC equipment. Any deviation of the support, load, placement, etc., will require CoreStates Group to generate an additional structural analysis. Further, no structural qualification is made or implied by this report for existing structural members not supporting the HVAC roof top equipment. For CoreStates Group 11 A John Scheffey, PE WA Professional Engineer #34844 cc: Jon Baske, Core States Group EXPIRES 08 -18 APPENDIX A CALCULATIONS Core States Group 501 Office Center Dr. Fort Washington, PA 19034 Standard Calculation Sheet Subject: Bed Bath and Beyond Tukwila, WA 1 of 7 Date: 6/27/2011 3:38 PM BBY -12825 Calculations.xmcd JOB NUMBER: BBY -12825 PURPOSE /ASSUMPTIONS The purpose of these calculations are to verify the existing structure for supporting the HVAC replacement units. Site name: #371, 400 Strander Blvd. Tukwila, WA Use ASCE 7 -05 and the IBC 2009 to calculate loads 1. Gravity Loads for New Equipment New Units Equipment Length, L := 72in Equipment Width, W := 36in Equipment Height, H := 54in Dead Load Equipment Self Weight, DLE := 14651bf 2. Wind Load On new Equipment per AS CE 7 -05,, per section 6.5.13 Feq. Input Rhor•- PROPOSED Rhor Rver (UPurr): 1 Rver (PRESSURE) — Location : Tukwila ASCE -7 Reference Classification: II (conservative) table 1.1 pg 3 Exposure category: Exp := Core States Group 501 Office Center Dr. Fort Washington, PA 19034 Standard Calculation Sheet Subject: Bed Bath and Beyond Tukwila, WA 2 of 7 Date: 6/27/2011 3:38 PM BBY -12825 Calculations.xmcd JOB NUMBER: BBY -12825 Velocity pressure: Wind area for equip, /keg := H•L Feq := Aeygz.Cf•G Rver := Feq• Feq Rhor 2 H•0.5 W Lineal Forces Rver Rver '= 7 f Rhor Rhor := 7ft Short direction: Fegs : = Aegs•gz CrG Lineal Forces Fegs Rhor 2 LL Velocity pressure coefficient: Topographic factor: Wind directional factor: Basic wind speed: Importance factor: Equipment height: (mid point) Gust response factor: Force coefficient: qz:= 0.00256•KZ.KZi Kd•V2.I. psf KZ := .7 KZi := 1.0 Kd := 0.85 V := 85mph I := 1.0 'h:= 25ft G := 0.85 Cf := 1.3 mph2 qz = 11•psf (Including the wind load area of the support beam) Feq = 3281bf Rver = 246 lbf uplift and pressure Rhor = 1641bf Rver= 351p11 Rhor = 231pl11 Aegs := H• W Feqs = 1641bf Rhor = 141p11 3. Snow Load per ASCE 7 -05 (Force couple) Aegs= 13ft2 table 6 -3 pg 79 sect 6.5.7.2 pg. 26 table 6 -4 figure 6 -lc table 6 -1 pg 77 section 6.5.8 pg 26 figure 6 -21 (Eq6 — 15) ASCE -7 Reference Core States Group 501 Office Center Dr. Fort Washington, PA 19034 Standard Calculation Sheet Subject: Bed Bath and Beyond Tukwila, WA 3 of 7 Date: 6/27/2011 3:38 PM BBY -12825 Calculations.xmcd JOB NUMBER: BBY -12825 Input Ground Snow Load: Thermal factor Exposure Factor Importance factor: Snow Load: Min pf pf := I.20psf Pf := max(p f, Pf) Pf = 20• psf pg:= 20psf Ct := 1.0 Ce := 0.9 I := 1.0 Pf := pg•I Ce Ct•0.7 4. Earthquake Loads: Design in accordance with ASCE 7 -05 Figure 7 -1 Table 7 -3 Table 7 -2, Exp C, fully exposed CAT II Table 7 -4 Pf = 13•psf Maximum Considered Earthquake Ground Motion at 0.2 Sec Spectral Response Acceleration at 5 percent damping for Class B site. SS := 1.4289 St:= 0.4895 Assumed site Class D ( Stiff Soil Profile) Table 1615.12(1) Site coefficient: Earthquake spectral response acceleration for short period Design spectral response acceleration for short period : Dead load Cabinets, DLE := DLE Dead load Platform, DLP := Olbf Total Dead weight: WE := DLE + DLP WE = 1465 lbf Ibs Using The procedure 13.3 in ASCE -7 Wpp := WE ap := 1.0 R P := 2.5 Ip := 1.0 Table 13.5 -1, ofASCE -7 Table 13.5 -1, ofASCE -7 (13.1.3), of ASCE -7 DLE = 1465 Ibf Fa := 1.0 SMS := Fa SS Eq 16 -37 IBC SDS := 0.67•SMS Eq 16 -39 IBC SDS = 0.957 Core States Group 501 Office Center Dr. Fort Washington, PA 19034 Standard Calculation Sheet Subject: Bed Bath and Beyond Tukwila, WA 4 of 7 Date: 6/27/2011 3:38 PM BBY -12825 Calculations.xmcd JOB NUMBER: BBY -12825 z := 25 feet h := 25 feet 0.4•ap•SDS•Wpp —z) FP := 1 + 2 FP = 6731bf IP Fp,,,ex := 1.6•SDS•IP•WPP Fp,,, = 22441bf ax Fp,,,i„ := O.3 • SDS• IP• WPP Fp,,,„ = 421 Ibf F = 673 Ibf SeisE := Fp SeisE = 673 lbf (Seismic load on equipment and support) Feq := SeisE H•0.5 Rver Feq' Feq Rhor 2 Rhor = 3371bf Rver = 505 lbf uplift and pressure Lineal Forces Long direction: Rver Rver •= 3 ft Rhor Rhor := 3ft Short direction: Rhor = 112.p14 RVer = 168• plf (Force couple) Rhor = 112•plf CHECK EXISTING BUILDING Existing Loads DEAD LOAD Roof Wood Beams 4 psf Wood Deck 3 psf Roofing 4 psf Mech/Ele. 4 psf Core States Group 501 Office Center Dr. Fort Washington, PA 19034 Standard Calculation Sheet Subject: Bed Bath and Beyond Tukwila, WA 5 of 7 Date: 6/27/2011 3:38 PM BBY -12825 Calculations.xmcd JOB NUMBER: BBY -12825 Check Total Roof dead load, DLroo SNOW LOAD f := 15psf • Building Snow Load, Pf = 20•psf Timber Beam for HVACLoading From Historical Joist Manual Published by SJI for 24H6 Joist Mall := 462000in•Ibf Ran := 5600Ibf Wood Beam itainnEi. 4, encel ® yew SaveQni' V $awe &Ezit '24.860 ft t4 5375 x13.250 Click on '!" to Add, OJ¢oe 5 an. Click on S -m t o S<Ls, Click on ::u rt to I todil E General'Data' (31025101;EIDlirr711, ,"'Span Loads 1 Loads Al Spans' 8 +1?Load Combinations' fe3= Slileci Span Max. Max'AOow t t Spin : I ' - Wood SectbA Name : 1 6.376X13.260 I Design Length ' I 2 166 . ft • Quick—List Fraper8es 71.219 in^2 Ix � 1,041.945 n" 4 IY 171.463 n^4 Cf or Cv for Bending .. (S4. trbil Cf or Cv for Compression (see tahl.': Use Cr : Repetitive 7 r Member t ihj '.. 1 h -AAow Total Deflection' Rano 180 13.25 } Member Depth = 1 13.25n live Load Deflection Raba Wood Gradtrt0/Manuf. : 'Wood Member Type : Word Zinn ..loos oa 'General oan•,ab ••• Cm: Wet Use Factor 1 11 Ct: Temperature Factor I 1 1 E ax.Combiations I , M V Summa Li Support Reaions I Design OK ' . f i L41 r - .. Check qe Maxln Maximum Bending Stress; Ratio -° :04495: 1 ,,�/ section used for this span 5:375 X 13450` I fb ; Actual., 2,319.95psi F8: Alowable ,2,S92:00 Load Combination +1.200+0.501141:605. _ Location ofmaximum on span 121330ft ; San #eivf maxman occurs. Span " #.1. �K/- Deflectionsfor miry Def1. Ratios, Extreme 0.+ x) or (L+S) Deflection , Max Downward 085 In Ratio '367 Support Max Upward - 76:660,i1 Ratto - 0 - Support Total Deflection ' "Max DgmmorelL 1.409,h Ratio a 210 Max Upward .0 000, in Ratio - 0 Joists Okay Glu Lam beam supporting joists Maxinium,Sheai,Stress Ratio -. ., '. Secllon used for, this spat fv : Actual , i FY Aiowable` Load Combination Location of maximum on span Span a where maximum paws Reactions; ( service, kips ) Lr L S �0 260: 1, 5:375 X-1312501 .95.57 p0 367.20psi +1.20D+o,50L +1.60$. - - 23.674R Sim # 1 W E 51 #1 1.48 #2 1.46' and unit 1.97- 1.97 Core States Group 501 Office Center Dr. Fort Washington, PA 19034 Standard Calculation Sheet Subject: Bed Bath and Beyond Tukwila, WA 6 of 7 Date: 6/27/2011 3:38 PM BBY -12825 Calculations.xmcd JOB NUMBER: BBY -12825 ' ' 'ii +$4 IV 82.0 ft: hA 8 8.75x40.5 Click on •J- to Add. hie,.: S -n, Click on S•an To S.:lect Click on Su ••• rt to tlodd. E .General Data ©!C Qom( 1 ! ,"'Span Loads If,. .CC /ads AO Spans l D.14 Load Co tnationsl Selela Span Max: Max: t rt . . I. it ® o ,' Span : Wood Section Name: 18.75X40.5 I _116 1 Length ■ I 62 4 ft ylst Fropertes ,) Member Width = I 8.7000 Min 1 Area . 354.38 h^2 llBow, Total Deflection Ratio i �',�u Member Depth .. 1 40.5_O14ivl ly h+4 48;438.6 WY Allow Uve Load Deflection Rath f 180.0 ,260.99 WOOd Cradrq/hlmr,f.: WeStem rWOed Member Type : 61.8 Wood TvM idi.'ted or. Yiera+t pm,ub , Cm: Wet Use Factor 1 11 Cf or Cv for g,, (s..) Ct : Temperature Factor ( 1 1 Cf or Cv for Contression (so rh: LJse Cr : Repetlttve 7 r SPIMMESIS E Max . Combhations l' E M',V -DSuinmaly I . E Support Reactions (, Design UK Maximum Bending Stress Ratio -. _, . 889: 1 .10 Section used for this span 8. 75x40.5 fb : Actual 2,892.600 RI :'App'urable' 3.253.93ps1 LoedComhhlatlon +1:20DW:SOL +1.61% Lolatlwt of avrernmon Spam 31.000 ft spill '8 where ma7wtun wars Span' i l'' ✓'Deflectionsifor,Min :PIfl” Ratios Extreme (L'A:O ar (L +S) Deflecton; .. . Mai Doerward 2.076. in Rano - .358: Support Max tAnerd '0.000 'In Rath' .4 0 Suppertt2 Tots! Deflection Max Downward - 3.632 in Raft:, - ,204' Max Upward ' o.000 h Ratio a 0 „'Maucrnim Shear Stress Ratio.-- 0 248 :;1 Section used for this span 8.75x40.5 , fv : ACtuai 141:71psi 1:=1.0: AOowabie 572.400 LoadCarnbttation +1.200+0SOL +L605 Location of maxtrmmi on span 58.900 ft Span # where Maid:M n ocass Span s 1' Reactions, ( service: kips) Y D - Lr L S W E 11 d1 11:16' 14.88 11:16- 14.88 - fbl := 2892psi Relative stress before unit is installed in glu -lam Core States Group 501 Office Center Dr. Fort Washington, PA 19034 Standard Calculation Sheet Subject: Bed Bath and Beyond Tukwila, WA 7 of 7 Date: 6/27/2011 3:38 PM BBY -12825 Calculations.xmcd JOB NUMBER. BBY -12825 Wood Beam `M1J X cancel ® New Save Qnit dove 8 Exit N- 62.0ft 5.75340.5 In in ( h.M on Su, crt l.i 1lr,/iF r General Data ix ,I Beam Span Data Select Span : 1 — Add Qel Load Load Select Load Type Nye au _Da Span Loads I Loads Ali Soars G +1 +fLnad Combination Load Source : Unused D Magnitude : Location 0.80 24 It ft Lr l copy Load '- Description : Point Load : D = 0.80 k gi224.0 fl Full Uniform 24.000 Foal! Load 24.000 1.000 0.0150 080 00. Summary Ras+jit6 I g Max. Combriatons I om M -V D Summary I 1: Support Reactions i/ Maximum Bending Stress Ratio = 1 Section used for this span 0 fb : Actual F8 : Allowable Load Combination Location of maximum on span Span 4 where maximum occurs 4 4; ✓ Deflections for Mn. Deft. Ratios (L+Li) or (L+S) Deflection Max Downward Max Upward Total Deflection Max Downward Max Upward i fb2 := 2950psi 2.076 in 0.000 in 3.715 in 0.000 n 0.907: 1 8.75x40.5 2,950.68psi 3,253.93psi +1.200+0.501 +1,60S 30.690 ft Span x1 Ratio = 'ill /3 Ratio = Ratio = Ratio = 260 f (- Auto add beam weight? S w Maximum Shear Stress Ratio = Section used for this span fv : Actual Fv : Allowable Load Combination Location of maximum on span Span 4 where maximum occurs Extreme Reactions ( service, kips ) Support 1 Support 42 Relative stress before after is installed in glu -lam (fb2 — fbl) Ratio := • 100 = 2 % fbl D 1r 11.85 11.47 E" .6k) --- __lk.._..._ 0 020 0.252: 1 8.75x40.5 144.20px 572.40psi +1.200+0.501 +1..605 0.000 ft Span *1 S U 14.88 14.88 H k Ake --------- - -- Ile) — Design OK Ratio = 2 % Which is less than 5 % and is allowed under the IBC 2009 for existing structures Roof is adequate to support Equipment exchange. APPENDIX B SURVEY NOTES CORE STATES Client Location CSG jobtt JITU Information Manufacturer Model # Serial # Catalog # Gas or Electric Heat Condensate drain type? • My vents within 107 Curb Dim (front to back) Curb Dim (right to Left) Curb Height GROUP U / /vV/L //, OH y - fd-fa S RTU 1 HVAC Roof -Top Unit Survey Form) Survey Date Surveyed By Facility Contact Phone RTU 2 Pal 9 RP 06- ? <f/ - and ,6 RTU 3 L Ci✓�0 x G f" N "0 x• 1/(%// 1,0 Y (f(S16 --13ri I--)V-74 ‘Cs16- I7?-77a - *6.1/d - 353- 270 -74 6 9,-/M,0-73 51q-f/14 ()l d3 q ,OC/M oia7a Th9'ti,44pta7/ S Pitt Mpdttl P_ 4Of' pool' F-vol- Az ,N 4 5 (169 /' 'toot: P.aOF A/ /i/ • Are condensate lines piped together or Just drain to roof? Notes: (27 (f P a. — T Aix S r 117-7-.6a Manufacturer Model # Serial # Catalog # Gas or Electric Heal Condensate drain type? • My vents within 107 Curb Dim (front to back) Curb Dim (right to left) Curb Height • Are condensate lines piped together or Just drain to roof? Notes: RTU 4 RTU 5 RTU 6 GENNOX L6NNOX (F.NNO X 4-c$ r6- I13r3 - x70 -74 ($,6 -1 '1.?.-,2?() -7 “ S l6 -1 ?53-x70 -7G •6v1 01040 Th9'ti,44pta7/ S Pitt Mpdttl 6 -4 5 4--d--) 4 5 (169 /' 'toot: P.aOF A/ /i/ /t/ 5` q ' 9 ‘ 0 9? ‘ Page 4of5 CORE STATES Client Location CSG job# GROUP T(,r/tw1L4- RTU Information RTUY 7 Manufacturer Model # Serial # Catalog # Gas or Electric Heat Condensate drain type? • Any vents within 10'? Curb Dim (front to back) Curb Dim (right to left) Curb Height • Are condensate lines piped together or Just drain to roof? Notes: HVAC Roof -Top Unit Survey Form Survey Date 1//' Surveyed By j74 ,rte q 12P Facility Contact Phone RTU) RTUY % (/ 13 N/1/0 X ti1� yy0 x lit % /)/ ivo x (,(-$/6--13 3- �7o -r‘. -CS ati - 013- 0o -4 (r6S /‘- f3S-?7o --$'C S 6g41 ,1(f 70 6gt/4 PLY'S 1 5 6q`IL 01 7.05- 3ZR 6q fiq5 Pc5 0 -CO ©o, 0.001` /✓ '(FS ef' 7/.3,f N 6 P 6 s- S-. 7 (163 No Litt'' b G3 Manufacturer Model # Serial # Catalog # Gas or Electric Heat Condensate drain type? • Any vents within 10'? Curb Dim (front to back) Curb Dim (right to left) Curb Height • Are condensate lines piped together or just drain to roof? Notes: RTU ' /0 RTU 11 RTU ' %� Page 4 of 5 GCS 7 t-i - e 6 ) 3 -130 - f 6 GGS - lb-1353-276 - S S E S6gyG b /701 ` 1-0,44,4-0j4 II l a 660N -6o6% S'614111rotirti3 3ZR 6q fiq5 Pc5 Gas " k o f '00,4 Rood' No P No Litt'' S 'I 1311 71 'Pi ,r 0" rr rOr (1/ Page 4 of 5 J3eam Information Beam Height Beam Width Afedet 1 FlangeThtckness Web Dimension (If possible) Web Dim :--- _ ,1i Beam 1 Beam 2 Beam 3 Beam 4 Beam 5 yo.,_„ 1 1 /id 1 £(6 ) 1 1 get" 1 1-755( 1q34/" 1 1 ?" — 1 1 .4.420W 1 ut/ as ! 1 wood 1 k1& P 1 v- 01), > 1 1 Supplementary Information Are block walls used to supporl Joists? (YESINO) Wall Height Wall Thickness Wall 1 Wall 2 Wall 3 Wall 4 Wall 5 /VD i 6ti A/P i Fr /1/d v4'7" H `A'S ati "5 ;y'9 ay '6 9-9" -- 6, „ Column Information Column 1 Column 2 Column 3 Column 4 Column 5 Are round columns used for support? (YES/NO) Diameter Thickness of metal (if accessible) Are square columns used for support? (YES /NO) Wdlh Thickness of metal (if accessible) /toot Framing Sketch Requirements: Masonry Walls Girders and Beams -- Localized Supports Under Curbing Column Locations Beam Shear Splice Locations RTU Locations v Column Grid Lines - Joists Orientation of Supply vs. Return within opening Column Grid Line Spacing Bridging /1/ / /%` •” DON'T FORGET STOREFRONT PHOTOS i" Page 3 of 3 Ream Information Beam Height Beam Width Fiattia itrail Web Dimension (if possible) v I LL Web Dim ><— Width 8 4 ,iJ Beanfg BeamY 7 Beam)(f Beam)l'q Beam,'■ 1 6 l A 5 /; 1 voote 1 \'1100i7 1 vu oar) 1 v-. 0or) 1 wow 1 1 Supplementary Information Are block walls used to support joists? (YES /NO) Wall Height Wall Thickness Wall'Y 6 - .WallZ_.._..__ WaN-3 Wall-4 Column Information Column 1 'CZ umt 2 --olumn 3- Column 4s- V ---Zolu in 5 Are round columns used for support? (YES/NO) Diameter Thickness of metal (if accessible) Are square columns used for support? (YESINO) Width Thieknes'1; 6rmetat•(ifeecessible)°— w 00 (02 /G/ t or 4 - Roof Framing Sketch Requirements: Masonry Walls Girders and Beams Localized Supports Under Curbing Column Locations Beam Shear Splice Locations RTU Locations Column Grid Lines Joists Orientation of Supply vs. Return within opening Column Grld Line Sparing Bridging "' DON'T FORGET STOREFRONT PHOTOS "' Page 3 of 3 Ream Information Beam Height Beam Width Flange Thickness Web Dimension (If possible) l/ Web Dim = E t.I Width t3r4Msj) Beam 6I Beamt2' tJ _Beam -3--- Spa - 5--- -- I Z r w el IN5 'A," 1 5 Yz/ 1 4 /Dodd 1 t4/0e7c( I supplementary Information Are block walls used to support joists? (YES /NO) Wall Height Wall Thickness Wall 1 Wall 2 Wall 3 Wall 4 Wall 5 Column Information Are round columns used for support? (YES /NO) Diameter Thickness of metal (If accessible) Are square columns used for support? (YES/NO) Width Thickness of metal (if accessible) Column 1 Column 2 Column 3 Column 4 Column 5 Roof Framing Sketch Requirements; Masonry Walls Column Locations Column Grid Lines Column Grid Line Spacing Girders and Beams Localized Supports Under Curbing Beam Shear Splice Locations RTU Locations Joists Orientation of Supply vs. Return within opening Bridging "' DON'T FORGET STOREFRONT PHOTOS "• Page 3 of 3 J J CORE STATES 3-0(57s -A 10 LI Structural Rooftop Survey Form Client location CSG jobff Building Information GROUP What year was the building constructed? Joist information Wh vas the joist manufacturer? Is the tag on the joist? (YES/NO If YES, prod de' •tag informalio What type of bridging', , ed? (Horizontal/Diagonal) Are the joists top f bottom adng? What is the J6 st span or length of isl? n ols What-t�tt olstspactrtg?-(iie"Twee j V M f /'T E/" /.ZL What- 19•thelntertorpanel•point•spacIng ?_(web sgace) What is the joist depth? (height) Vv 1 D7- / ) V1 hat is the helght_oi.Rhe joist seat? ( 5: -,- other) Joist Sketch: Joist 1 Survey Date Surveyed By Facility Contact Phone or approximate age of the structure? Joist 2 Joist 3 Joist 4 Joist 5 1 1 1 Lvecod I of ')P I woo 1 vt -oof) 1 woo/ 1 1 /2, % //I 1a 5/; 1 f$/ 1 (3•f 1 j2% 1 1 tt%" 1 1 9 r 1 'e 1 59)co 1 Page 1 of 5 700 TS® GORE STATES ®`a Structural Rooftop Survey Form Client Location CSG John Building) Information GROUP What year was the building constructed? Joist Information Who was the Joist manufacturer? Is there a tag on the joist? (YES / NO) If YES, provide tag Information What type of bridging Is used? (HorizonlavDIagonal) Are the joists top or bottom bearing? What Is the joist span or length of joist? What Is the Joist spacing? (between Joists) WhaHs the - interior penekpoin€s ny?-(web space) what Is the joist depth? (height) Widtti a is s e ht=ehthe leiet -seat? (2.5 °, 5 °, other) Joist Sketch: Survey Date Surveyed By Facility Contact Phone or approximate age of the structure? Joist)( (0. Joist= 7 Joist T Joist, Joist-i )0 w007.4 1 iti (9(9f) I w 00P 1 ''O// 0 1 Z" I I -' 1 13 /6 1 Ja ,f'' 1 Page 1 of 5 is 1 5f 1 s /"1 I '-rvV i nn cPr 4 1 CORE STATES w 1 Client Location CSG jobIII Bulldine information GROUP What year was the building constructed? Joist Information Who was the joist manufacturer? Is there a lag on the Joist? (YES/No) If YES, provide tag Information What type of bridging Is used? (HortzontaUDiagonal) Are the Joists top or bottom bearing? What Is the Joist span or length of joist? What is the joist spacing? (between joists) WIrdris- thednledor Dane! ootnt & aclr a fweh_apgce) What is the joist depth? (height) What What rs4 H (his% set? (2.5 ", 5 ", other) Joist Sketch: J-0 (5 7S Structural Rooftop Survey Form Survey Date Surveyed By Facility Contact Phone or approximate age of the structure? Joist ( vfst1 "Titr4--°-- -- --- -- Joist.S_._... 1 tr/ GUl( 1 [ 5 %z" 1 Page 1 of 5 Revisions NO.; ORK REQUIRED ON NO WORK MAINLEVELAREA (/ - O0 j�' �/2� / / N0 i -�0oi 001/01 w _w•"' ..rr ,.. .. .. f a v 1 ,.. I� ay.�.ro-.aaw ... "„IIAII■� .rte . ��_ l{! 1 tia �... N I lu - mI -0 i ' ifilim.fil x. 11 li - I...l / - -IB 1,n " L 02 * ° 1,1 NI, II 11 — . i i, , UN �I rfi ILA %1 i� 1 �s a ' / s� �roin le -. er k, «., 4 �^^�^^I^ �� . II u -e 1 oof* 11 ■ • - O. FIXTURE PLAN - MAIN LVL. Cpl m i5 �, — ! • i n LLLli a saLe ....1,v. rNy. �y�1 t�...t:�o.. ��1; 1i /i IrE,i�' 1 I— u (p� (('�� 4 Y ✓Y �� �1 _ �� dll a_ I _,i l�l�l� &fit Drawing References Na - 1 I ' 1ftlE163 Mil 111 = /..__. 11 ia'.: N.:1 ® HI Eill 591 I! I 1 1 ® 1 _ r 69 ,===..4 II 1 1 A ...,I}a: -I ®IiM 11 m 7:1 : ' •� Ri sp...-4 1;71 PROMO 7: mo " ^_- n1o<a.m: � 1 ''- t .... i ® I -< 1 • !(!.�I.,,"��--__ -11 'Y ' 11 CO IN 11 .1 oww.r: osoxbi t _Ida— rwmmeuaiwma _ �-- -Bo ❑ - = nil .fz �emil 11 W 1■I N1 -••I. I::: - �_i ;__° F. Q C s ,p� 11_::1 �.�:1 `. 11 (n� (� ✓ 1' ✓ .T G. ' ) �Q - -_ .•_._ �" 1 1 1 °'•" ° �°.. "b= �O���I. A it RP ®dl RUM" I�GCI ;�' I�y I' L �n °��! • �� 1� 0 �y 1 �1 1 I _.. ■_. 11 Il I3I i-- Il ® IBC -� r F� L�l it t► I+� �..__ jj 1 j m L.ernx «�1 11 B ®f3 H Q 8 ;.m_ I 1 ® 1-:1 ' 1: i. :awl, !! 11 II 1 II 11 I � fy f �j :I p uII t •® BED BATH & sEY�/�is eaeuemnavE UM, N.107061 COMMON fAxuo»ee.aae. N b n tl qq t ��L , t-1 .= 1 '- s; _�; l I °I - ��` ►a �M q_�tl Z r p Po W l ® � is .__ a 1 Ii , 1w Its {• �. L.'_ -1`.:i l ❑ Ian _ r'�• -_ • I i I 1![ 7 1■Z.Ui lL °MU �sl... '' iilri+ � - ,. I ■■ �.�I :7R't5 i H,;F'i -'` " 1:Iil% 11 11 11 I■ 11 II 11 11 - - 11 - �11 _ 11 ■ 11 a 1__I I_ =1 '- 1--1 I-_1 ^-. -- =1 +a-.r �1 a!w�atsfl IL.., . 111 11 tl 1 11 11 �.._- niwawwmuus oxu SSVEMPcanu rcow111100«1D.TMIuFaoumNaOWNMAY xmlour MUM= a.EO aanl a earmm. =MUT>EOwwn�.uuxawMxIOND. 1 .. 1�_1 js 1 III 1Q °�I ®�_ 11 1, ______., 11 �' I 1 .-. _ IV* l Q _ w.' >llni ._, 4. Na � 1' ��� .•4 } 4. i + 1, Ma f -= l i N/ 1 .t _ • 11 ✓• V4 Sa "-. Fi �' LODZ. #371 TUKWILA, WA 0(01.9 Me FIXTURE PLAN 1 l,. AV.. 6 6 6 6 6 6 6 6 6 b 6 b 6 6 6 - &,;• I Cale SEE PLAN luaus FIXTURE PLAN 01 S "`t No. F 1 A SCALE: Mr -VW it re ;4 fog ea becill /11' /1/fr (A \I , • (fly k VT,/ : - -- • -;P7'..1 1-42:•,i- • i ; • CITA ar....110 ..tviriga- 1 2J.*-0 :::i •11*-0: ..- F. 24' -G." J, t. 1 1 i •:, Stn. MK)? 07.0/01.11T Mit..i(INI). I.E.Ix.) •' •••••••-•-`,Sr 1.11.1M. 4■.11■1• —L 27'(513 sec,i) F-1) El r7.--rj j t LILij .7-1r4 !• ;.. . FIL 1:! t i.L.0 ..__. , . ..1 . _..:, .,.,... I . 15:•-•4 VT 1.-J L..14,4 _.r _ — — • 17"1" -- -.•-•,--- '• 2 l'--•?. I/ 7::::-E,',,;...;-.-.,----4.-t--1,73,ki,i I : FTG PRE—S/ALES •7727.7=-:17.7.1—.11- 1 • ; 1 -7- u. 1 - ,--7..r------- --" .41 • i ....r ••_ ()Mille) EDNizEc. CutittVAI WO awl IC, at r$Z,1 RCL la rixcz 11barAtzu Of IliCSDIS (1 ...) TRASH 1tES•1= 11EGMER-•,-• pia TO Et 1 • • WA Es4ST.COICLiti '1. i lXvon %p.m wsit 1 i 1 L-- , -:;;;;-■ -L-*■-■... ■ 6-1 .,„,, -.3- -- -,- ) ,,,Iz---.7740:747,t4467,-. ' • DM StsPE111 SusPlifo -- --..\.., I 1 8 OSTAILLX, By C.C. 1 1 I 1 i 1 i2 :••4*-C•' I •E____:,__ i I .........1..':S.`... ..,. . 1 . , s.,_ . • -.1 "'"'"'""'"-"—"-*------!"7,..i:77;kp a:rlitir;i: c.:tv-Lh.t.ii:*.I.• : ! 1. I • e■ • r . \ f '1 c '-• C •1 .:. ., ' I (-1 i s, -} '1/4, ,... k:.). . F69/0 N6- Pc /z/v I FAI N '.7 _ter....: •�zs•_: • WaU? pV' Ca1r� Q1'JSM 1070 l06L7 . • (- )0'4`� r- —T- cos,r7 !AO :• finlfT'"I • . FILLO'd'i " ' 10 ... r, 4 i�_ r-' -lem.� --�-� jam- , l -n. } 7-79., E - - -- •r• - --∎- —aS'x • KIT .I N BASICS - 6riiA -I. _ E ._ _.�' t I " - • CI k.: • ..{: —_ ' , i , - A L._... z : t17 Val • fR`r ro:E? ?,rST: i's++Iaatn ow. - +'- •�a:�.= +'L -x..: .!I�e =..x• EL,._: c. .a.�c......+...:rllaw.rc:.,.t -f ��4 ,_� -' ri ,g —ois s • CO t J APPENDIX C PHOTOGRAPHS Picture 1: Picture of typical roof joists and beams Picture 2: Wood roof beam hung on Glue -Lam Girder Picture 3: Rooftop and units of building Picture 4: Plaque from one of the Units to be Replaced Picture 5: HVAC opening framing from below 11 -01 -2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director ANDI VAN BLARICOM 5005 THIRD AV S SEATTLE WA 98134 RE: Permit No. M12 -036 BED BATH & BEYOND 400 STRANDER BL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/09/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/09/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 0 c Bill Rambo Permit Technician File: Permit File No. M12-036 6300 Southcenter Boulevard, Suite #100 • Tukwila. Washington 98188 • Phone 206 - 431 -3670 • Fax 206-431-3665 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director March 15, 2012 Andrea Van Blaricom McKinstry Co 5005 Tghird Av S Seattle, WA 98134 RE: Correction Letter #1 Mechanical Permit Application Number M12 -036 Bed Bath & Beyond — 400 Strander BI Dear Ms. Van Blaricom, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and be reflected on your drawings. I have enclosed comments from the Building Department. The Fire Department has no corrections at this time. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File: M12 -036 W:\Permit Cen ter \Correction Letters\2012\M12 -036 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: March 14, 2012 Project Name: Bed Bath & Beyond Permit #: M12 -036 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide engineers calculations and drawings wet stamped and signed by the engineer and/or architect providing those documents. Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. ()PERMIT CO PLAN REVIEW /R • ING SLIP ACTIVITY NUMBER: M12 -036 PROJECT NAME: BED BATH & BEYOND SITE ADDRESS: 400 STRANDER BL Original Plan Submittal Response to Incomplete Letter # DATE: 04 -04 -12 X Response to Correction Letter # 1 Revision # After Permit Issued DEPAR MENTS: i ding ivision Public Works ❑ Fire Prevention Structural Planning Division n Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 04-05-12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route $ Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: n Approved with Conditions DUE DATE: 05-03-12 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit "Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -036 PROJECT NAME: BED BATH & BEYOND SITE ADDRESS: 400 STRANDER BL X Original Plan Submittal Response to Correction Letter # DATE: 03 -09 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPA THE TS: ilding Division 'Fire Prevention 111 Planning Division Public Works n Structural Permit Coordinator p DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ,N] Incomplete DUE DATE: 03 -13 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 04 -10 -12 Not Approved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2-28-02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: (--! - ( /Z-00- Plan Check/Permit Number: 1V112-036 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Bed Bath & Beyond Project Address: 400 Strander Bl Contact Person: ANOMA ■JPt- QL16- -lCtM( Phone Number: ZOC, (974-a) Summary of Revision: Pg-QM P O Sl-uG UZP . & t-c 1-\.0.0- REcelvect CITY OF V_1ovitA EAPR .0 .4 2012 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date o revisi Received at the City of Tukwila Permit Center by: }-- Entered in Permits Plus on \applications \forms- applications on Tine \revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople Peter Friendly Page General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MCKINSTRY CO LLC UBI No. 602569922 Phone 2067623311 Status Active Address Po Box 24567 License No. MCKINCL942DW Suite /Apt. License Type Construction Contractor City Seattle Effective Date 3/16/2006 State WA Expiration Date 3/16/2014 Zip 98134 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LYDIGML901JLLYDIG+ MCKINSTRY LLC Construction Contractor General Unused 4/13/2010 4/13/2014 Active WESTVI`121RF WESTVENT INC Construction Contractor General Unused 12/6/1988 9/1/1994 Archived MCKIN * *372N0 MCKINSTRY CO Construction Contractor General Unused 8/20/1963 1/2/2008 Re Licensed Business Owner Information Name Role Effective Date Expiration Date PEDERSEN, JAMIE D Agent 03/16/2006 Bond Amount ALLEN, DEAN CHARLES Partner /Member 03/16/2006 929519469 MOORE, DOUGLAS JAMES Partner /Member 03/16/2006 ALLEN, DAVID EDWARD Partner /Member 03/16/2006 WESTERN SURETY CO TEPLICKY, JOSEPH WILLIAM Partner /Member 03/16/2006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 Western Surety Co 929519469 03/01/2011 Until Cancelled 01/23/2012 $12,000.00 02/24/2011 2 WESTERN SURETY CO 929511574 09/09/2010 Until Cancelled $12,000.0009/02 /2010 1 TRAVELERS CAS SURETY CO 104702039 01/03/2006 Until Cancelled 03/01/2011 $12,000.0003/16 /2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Zurich American Ins Co GLA 3999903 01/31/2012 01/31/2013 $2,000,000.00 12/16/2011 4 ZURICH AMERICAN INS CO GLA3999903 01/31/2011 01/31/2012 $2,000,000.0012 /20/2010 3 ZURICH AMERICAN INS CO CP0399990301 01/31/2009 01/31/2011 $2,000,000.0012 /07/2009 2 ZURICH AMERICAN INS CO CP03999903 01/31/2008 01/31/2009 $2,000,000.00 01/31/2008 https://fortress.wa.gov/lni/bbip/Print.aspx 04/09/2012 \ \MCKDATA \DATA \SERVICE \SALES \SERVICE SALES PROPOSALS \VAN BLARICOM \BBY \371 \M1.O.DWG PLOT DATE: 02 -21 -12 0 23' -7e CLEAR o8'- 11' -6" CLEAR ? 24' -0" 24' -0" CLEAR 36' -7" r 40' -7 a M 0 48' -0" 2 24' -0" 24' -0" 24. 192' -lh" CLEAR ? 24'- 24' -0" 23'- 12 24' -0" • 11 27' -6" 1' 16' -4" a 1 24' -0" / 24' -0" 48' -4" 24' -0" 24' -0" 34' -6" x_21' -3" a to P n" 44' -0" N to U a 31' -11" 24' -0" I0 32' -7" 40' -0" 4 a 1- a 24' -0" 60' -0" (0 to R-- i REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 9 2012 tors- N1A; City of u ila BUILDIN VISION FILE COPY Permit No. AA 1/ • , Pier rnview approval is subject to WWI and omissions. Approval of construolo documents does not authoriA tic violation of any adopted code or orb. Recel of approved and conditions Is McKINSTRY DIVISION: Date, y For Th PROJECT: instry !/e Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATHE, WA 98124 1 -800- 669 -6223 PORTLAND: 16790. NE MASON ST POR11AND, OR 97230 503 -331 -0234 www.mckinstry.com BED BATH AND BEYOND #371 400 STRANDER BLVD TUKWILA, WA 98188 REGISTRATION: ISSUES: 02/21/12 PERMIT SET DATE ' -o" 24' -0" 24' -0" SEPARATE PERMIT REQUIRED FOR: D Mechanical Electrical tumbing Gas Piping City of Tukwila BUILDING DIVISION o CLEAR ? MECHANICAL ROOF PLAN SCALE: 1/1r = 1' -0" 0 8' 16' 32' REVISIONS No changes shall be made to the ecope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submlttc-I and may include additional plan review fees. zod City Of lbkwila BUILDING DIVISION DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DESCRIPTION ENGINEERING ALI SADIGH DOREL PURAVE• ALI SADIGH X DATE: 02/21/2012 SCALE: AS SHOWN SHEET TITLE: RECEIVED MECHANICAL ROOF PLAN RE MAR C 09 2012 PERMIT CENTER SHEET NUMBER: t1i1-03& M1.0