HomeMy WebLinkAboutPermit M12-050 - ENYEART RESIDENCEENYEART
RESIDENCE
11818 44 AV S
M12 -050
City oititukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No.: 3347400985
Address: 11818 44 AV S TUKW
Project Name: ENYEART RESIDENCE
Permit Number: M12 -050
Issue Date: 04/05/2012
Permit Expires On: 10/02/2012
Owner:
Name: ENYEART JADANNE L
Address: 30118 27TH S , FEDERAL WAY WA 98003
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Email: SHARYN.PARKER @KINGCOUNTY.GOV
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI9190A
Phone: 206 - 296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS
AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND
STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND
MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Mechanical: $1,716.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
Fees Collected: $167.70
International Mechanical Code Edition: 2009
Date: rl —'--- `2
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of wo I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit
Signature:
Print Name:
Date: t////
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M12-050
Printed: 04 -05 -2012
PERMIT CONDITIONS
Permit No. M12-050
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IMC -4/10
M12 -050 Printed: 04 -05 -2012
CITY OF TUKWILA
Community Develop Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http.- /h vww. ci. tukwi la. w va. us
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Site Address: 11818 44th Ave. S.
Tenant Name: Jadanne L. Enyeart
Property Owners Name: Jadanne L. Enyeart
King Co Assessor's Tax 1 o.: 3347400985
Suite Number: Floor:
New Tenant: ❑ Yes ..No
Mailing Address: 11818 44th Ave. S.
Tukwila
WA
98178
CONTACT PERSON - who do we'contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL, CONTRACTOR. INFORMATION
(Contractor Information for Mechanical (pg "4)'for Plumbing and Gas Piping (pi 5))
Company Name: not yet awarded
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
City
Day Telephone:
Fax Number:
Expiration Date:
State
Zip
ARCHITECT 'OF RECORD All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
SM Stemper Architects, PLLC
4000 Delridge Way SW, Suite 200
Seattle
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
WA 98106
City State'y
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973 ,
ENGINEER OF RECORD ='All plans must be wet stamped by;Engineer of Record:
Zip
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
H:Wpplications \Forms - Applications On Liae\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
City
Day Telephone:
Fax Number:
State
Zip
Page 1 of 6
TibILDiNd PERMIT INFORMATION,- 206 -431 =3670
.: '_ `• 17,932 , ti
Valuation of Project (contractor's bid price): $ Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
1 Floor,
,2nd Floor.
L. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below ,
Floor '"j'' . ;� "•,\
Floors'".';
Basemen
Accessory Stricture
Attached Garage
Detached Gara
Attached 'Carport
Detached`Carpa
Covered Deck•:
UncoveredDeck
PLANNING DIVISION:
Single family building footprint (a : of the foundation of all structures, plus any d s over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, pr de the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide document. . n that shows that the principal owner lives in one of the d - ings as his or her primary residence.
Number of Parking Stall rovided: Standard: Compact: Handicap:
Will there be a chang= use? ❑ Yes IJ No If "yes ", ex. in
xis
nterior Remodel
Addition to'
Existing
Strcture
745
ew
.t'Type of _
Construction per
IBC
Occupancy
FIRE PROT ION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None
Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fotms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
MECHANICAL CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Mechanical work (contractor's bid price): $ t 1( lD • 06
Scope of Work (please provide detailed information):
Use: Residential: New .... ❑ Replacement .... ❑
Commercial: New .... ❑ Replacement .... ❑
Fuel Type: Electric ❑ Gas .... ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
. Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace>100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
t
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1,750,000 BTU
Repair or Addition to.
Heat/Refrig/Cooling
System
Incinerator - Domestic
Other Mechanical
Equipment
Air Handling Unit
<10,000 CFM
Incinerator — Comm /Ind
H:\Applications\Fonms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 4 of 6
Scope of Work (please provide detailed information):
Call before you Dig: 1- 800 - 424 -5555
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑ ...Tukwila ❑...Water District #125
❑ ...Water Availability Provided
Sewer District
❑ ...Tukwila
❑ ...Sewer Use Certific
Septic System:
On -site Septic System — on -site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with A s r lication m boxes which a s r l :
❑ ...Civil Plans (Maximum Pape ''size — 22" x 34 ")
❑ ...Technical Information Report (St \9 Drainage) ❑ .. Geotechnical Report
❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s)
❑ .. Highline
❑...Valley View ❑ .. Renton
❑ ... Sewer Availability Provided
❑ .. Renton
❑ .. Seattle
Proposed Activities (mark boxes that apply):
❑ ...Right -of -way Use - Nonprofit for less than 72 urs
❑ ...Right -of -way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right -of -way ❑
Non Right -of -way
❑ ...Total Cut
❑ ...Total Fill
❑ ...Sanitary Side Sewer
❑ ...Cap or Remove Utilities
❑ ...Frontage Improvements
❑ ...Traffic Control
❑ ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
cubic yards
cubic yards
a
❑ ...Traffic Impact Analysis
❑ ... Hold Harmless — (SAO)
❑ ... Hold Harmless — (ROW)
❑ .. Right,-cif-way way Use - Profit for less than 72 hours
❑ .. Right-of- -way Use — Potential Disturbance
❑ .. Work in Flood Zone
.. Storm Drainage
.. Abandon Septic T
CurC• t
AV
Pavement Cut
%oped Fire Line
❑ ...Permanent Water Meter Size...
❑'...Temporary Water Meter Size..
❑ ...Water Only Meter Size
❑ ...Sewer Main Extension
❑ ...Water Main Extension
„
Public ❑
Public ❑
El.. Grease Interceptor
❑ .. Channelization
❑ .. Trench Excavation
❑ .. Utility Undergrounding
WO #
WO#
WO #
Private ❑
Private ❑
❑ ... Dedu
ater Meter Size
FINANCE INFORMATION
Fire Line Size at Property 1/lle
❑ ...Water ❑ ...Sewer
Monthly Service Billing to:
Name:
Mailing Address:
Number of Public Fire Hydrant(s)
❑ ...Sewage Treatment
Day Telephone:
Water Meter Refund/Billing:
Name:
Mailing Address:
City
Day Telephone:
State
Zip
City
State
Zip
H:\Applications \Forms - Applications On L1ne\2009 Applications \1 -2009 - Permit Applicatioa.doc
Revised: 1 -2009
bh
Page 3 of 6
PERMIT APPLICATION NOT Applicable to all permits in this a
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED
Signature:
Print Name:
Timothy J. Fe =Son, SM Stemp,7. rchitects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Date: !i''( YV/t
Day Telephone: (206) 624 -2777
Seattle
WA 98106
City
State
Zip
Date Application Accepted:
Date Application Expires:
Staff Initials:
H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 -43 - 670
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Intl Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Indicate type of plumbing fixtures and/or gas pipin . utlets being installed an
Fixture Type:
Qty.
:Fixture Type: > ;.;
3,
. Q h'..
Fixture t ' e:
Qty .
F•
Fixture Type -::::,
Qty';:
Bathtub or combination
bath/shower
Bidet
,
Clothe. 1 asher, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Lavatory
F.y. I -waste grinder,
/.mmercial
ash fountain
Floor Drain
Receptor, indirect waste
Shower, single head trap
Sinks
Urinals3.ater
Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Indu • I al waste treatment
interc- .; or, including trap
and ven `` - cept for kitchen
type greasy ` terceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alterati Pi of
water piping a s /or water
treatment eq _ ,I ament
Repair or alt tion of
drainage or vent • iping
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Each additional medical
gas inlets /outlets greater
than 5
Backflo 1rotective
device '.ii}er than
atmo-p eric -type vacuum
br- • ;sY`ers 2 inch (51 mm)
.' s eter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
'
• tmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:\Applications\Forms- Applications On-Line \2009 Applications \I -2009 Permit Application.doc
Revised: 1 -2009
bh
Page 5 of 6
Cie of Tukwila,
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670 '
Fax: 206-431-3665
Web site: http: //www.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R12 -01243
Initials: WER
Payment Date: 04/05/2012
User ID: 1655 Total Payment: 6,715.15
Payee: PAMELA K KUEHL (PHONE)
SET ID: 033012 SET NAME: KING COUNTY HOUSING AGAIN
SET TRANSACTIONS:
Set Member Amount
D12 -099
D12 -100
D12 -101
D12 -102
D12 -103
D12 -104
D12 -105
D12 -106
D12 -107
D12 -108
D12 -109
D12 -110
D12 -111
D12 -112
D12 -113
M12 -041
M12 -042
M12 -043
M12 -044
M12 -045
229.85
220.30
334.07
304.27
191.65
228.20
326.62
210.75
210.50
220.30
311.72
172.55
248.95
419.17
503.80
167.70
167.70
177.10
167.70
167.70
M12 -046 167.70
M12 -047 167.70
M12 -048 167.70
M12 -049 167.70
IM050 - 167.70
M12 -051 167.70
M12 -052 167.70
M12 -053 167.70
M12 -054 167.70
M12 -055 225.25
TnTAL: 229.85
Ci* of Tukwila, •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: law : /hvww. ci. tukw ila. wa. us
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA
ACCOUNT ITEM LIST:
Description
TOTAL:
6,715.15
6,715.15
Account Code Current Pmts
BUILDING - RES
MECHANICAL - RES
STATE BUILDING SURCHARGE
000.322.100
000.322.102.00.0
640.237.114
TOTAL:
4,065.20
2,582.45
67.50
6,715.15
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF' TUKWILA BUILDING DIVISION
6300 SouthcenterBlvd., #100, Tukwila. WA 98188 z, (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
72742-000
Project:
F'n/ ,g 7 RF S
Type of Inspection:
r.1�v4 L..
Address:
/i6,a y i9j/ 5
Date Called:
Special Instructions:
•
Date Wanted:.
a.m.
Requester:
Phone No:
S 3 li 7- 41ge_.2
Approved per applicable codes. a Corrections required prior to approval.
COMMENTS:
Inspecto
Date:
`EIN,SPECTION FEE REQUIRE'. Prior to next inspection. fee must be
paid/at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
-
•
PLAN RN
•
NG SLIP
ACTIVITY NUMBER: M12 -050
PROJECT NAME: ENYEART RESIDENCE
SITE ADDRESS: 11818 44 AV S
X Original Plan Submittal Response to Incomplete Letter #
DATE: 03 -30 -12
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Msion
Public Works n
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
DUE DATE: 04 -03 -12
Complete Incomplete ❑ Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 05 -01 -12
Approved n Approved with Conditions Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Pr, ter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with LW to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCCI9190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135931
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
5
Landmark
American Ins Co
LHA135931
03/01/2012
03/01/2013
$1,000,000.0003
/06/2012
3
Landmark
American Ins Co
LHA135245
03/01/2011
03/01/2012
$1,000,000.00
03 /07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.0003
/10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01/2009
03/01/2010
$1,000,000.0008
/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
04/05/2012
•
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CI RC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
VD
VTR
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
XX
ABBR
OR (
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
0 ROUND DUCT DIAMETER
X/Y -. X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
/ / / / / / / //.
CD
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING. INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -O" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
10.
11.
12.
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
SYMBOL
SG-X XX
ABBR
s.
'E #
+ f +
40is
I� OR
EQUIP ID#
x
NG
171
•
3
0
D'a
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
VD
RA /EA
RG
SA
SA
RA /EA
SD
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
DESCRIPTION
VOLTS
PH
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
15
16
15
16
N/A
15
16
N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
X
4"
4"
X
DECO
1, 2, 3
X
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
1,2
-
SWITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
140
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH : "SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
2
SG -1
140
<08" WG
8"
8"
CEILING
DECO
1, 2, 3
OG -1
90
<.08" WG
7"
7"
WALL
WALL CAP
1, Z 3, 4
RG -1
25
<.08" WG
4"
4"
CEILING
DECO
1, 2, 3
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1832
802
2
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE INOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 01011 AND 02080 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
FILE COPY
DSOPePermit No. tit ():' .
Pi¢', review approval Is subject to errors and omissions.
lc,. -.tat of construction documents does not authorize
t <, •. ,ktion of any adopted code or
4,. ordinance. Receipt
. 1., , r1 , •
�■ ■ is acknowledged:
of Lpf roved Fleid
/i/
By /,
Date' W'i //z.
SEPARATE PERMIT
REQUIRED FOR:
Cilechanic at
[nn lectrical
lumping
13'6as Piping
City of Tukwila
BUILDING DIVISION
City Of Tukwila
BUILDING DIVISION
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
REVIEWED FOR
I OWE COMPLIANCE
APPROVED
APR 0 4 2012
MIL
City of Tukwila
BUILDING DIVISION
MECHANICAL VENTILATION
CALCULATION RECEIVED
PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / ( &EGR X F)
QR = (FROM TABLE 403.8.1) la
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1a
QF =45/(1 X1 /2) =90CFM
MAR 3 0 2012
PERMIT CENTER
1O5D
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional Limited liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • PAX (206) 624 -2973
THE GREENBUSCH GROUP, INC
)))
N210 WED A YE251210&. B OINEEMN0
1900 >I�I 9116E1 SIRE POI IMRi. lw 1111111
(206) 376 -0669 (206) 372 -0041 FAX
0810.03.1832
0
J
z
0
i-
w
z
z
O
0
z
MPROVEMENTS
0
w
w
ce
w
0)
0
ce
z
Q
J
Q
F-
LU
0
U)
w
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
LEGENDS,
SCHEDULES, .
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1832
SEE
LAUNDRY
ROOM
IBEDR OOM
2
SEE u' n TYP ALL
CEILING GRILLES
KITCHEN
4"0
SEE
LIVING
ROOM
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
INSTALL PER THE
MANUFACTURER'S
WRITTEN INSTRUCTIONS
OUTSIDE AIR
DUCT
16" MIN
RETURN AIR
DUCT
FILTERS ACCESS
MOTOR ACCESS
HOLD TIGHT TO
STRUCTURE
ATTI C
USE EXISTING ATTIC
ACCESS HATCH FOR
ELECTRICAL AND
MAINTENANCE
ACCESS
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSULATE ALL DUCT AS SCHEDULED.
BLENDING UNIT INSTALLATION DETAIL
NONE
CIFNORTH
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DRAWING NOTES:
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS
AT MINIMUM 10 FEET AWAY OR 2 FEET
BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
2. HEATING IS PROVIDED BY ELECTRIC
BASEBOARD HEATERS.
DUCT PER PLAN
FLAG NOTES:
BV -1 AND DUCTWORK ROUTED IN ATTIC. USE
EXISTING ATTIC ACCESS HATCH FOR
MAINTENANCE AND ELECTRICAL ACCESS.
ELECTRICIAN TO PROVIDE PROGRAMMABLE
TIMER SWITCH BY TECHNICAL SPECIFICATIONS
SECTION 16100. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)"
PER WAC 51 -52- 0403.8.2 -5.8.
TRANSITION DUCT TO AIR TERMINAL NECK
SIZE IMMEDIATELY BEFORE MAKING FINAL
GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS
REQUIRED TO INSTALL OUTSIDE AIR INLET,
REFER TO ARCHITECTURAL DRAWINGS AND
TECHNICAL SPECIFICATIONS.
INSULATE ALL DUCTS AS SCHEDULED. REFER
TO THE MINIMUM DUCT INSULATION
THICKNESS SCHEDULE ON M1.0.
CAULK
FOAM BACKER ROD
WALL CAP OR SIDEWALL GRILLE
SLEEVE AND ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1/A2.2 FOR DETAIL.
WALL CAP INSTALLATION DETAIL
NONE
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER
2. SEE PLANS FOR VOLUME DAMPER LOC
3. CEILING SUPPLY INSTALLATION SHOWN,
DUCT PER PLAN
COORDINATE SOFFIT WITH
TECHNICAL REPRESENTATIVE
FIELD FABRICATE PLENUM
BEHIND CEILING GRILLE
CAULK
FOAM BACKER ROD
ARCHITECT TO PROVIDE 2X4
BLOCKING TO SUPPORT CEILING
CUTTING
FLOOR OR CEILING JOIST
CEILING
SLEEVE AND ESCUTCHEON
GRILLE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
ATIONS.
RETURN SIMILAR.
CEILING GRILLE INSTALLATION DETAIL
tODE REVIEWED FOR
COMPLIANCE
APPROVED
APR 0 4 2012
BUILDING Tukwila
RECEIVED
MAR 3 0 2012
PERMIT CENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A FroteaulorW Limited L1aMHty Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 924 -2777 • FAX (206) 624 -2973
THE GREENBUSCH GROUP, INC
eeeeeeeee�
11011 MUSE MEET &ME 201 SEIM 161 121Iv
(206) 378 -0569 (206) 376 -0641 FAX
0810.03.1832
KING COUNTY INTERNATIONAL AIRPORT
1-
z
w
w
0
0
0
w
2
w
w
O
LL
U
z
w
0
w
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
MAIN FLOOR
MECHANICAL
PLAN AND
DETAILS
M2.0
0810.03.1832