HomeMy WebLinkAboutPermit M12-051 - KALALAU RESIDENCEKALAIAU RESIDENCE
12048 44 PL S
M12 -051
City oikukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206.431 -3670
Inspection Request Line: 206- 431 -2451
Web site: http: / /www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No.: 3347400860
Address: 12048 44 PL S TUKW
Project Name: KALALAU RESIDENCE
Permit Number: M12 -051
Issue Date: 04/05/2012
Permit Expires On: 10/02/2012
Owner:
Name: KALALAU PATRICK K +DESIREE A
Address: 12048 44TH PL S , SEATTLE WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Email: SHARYN.PARKER @KINGCOUNTY.GOV
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI919OA
Phone: 206 - 296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS
AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND
STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND
MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Mechanical: $1,599.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
Fees Collected:
$167.70
International Mechanical Code Edition: 2009
Date: 4-C
f2
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Signature:
Print Name:
/■
SSE /4 &
Date: y /ch Z
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M12 -051 Printed: 04 -05 -2012
• •
PERMIT CONDITIONS
Permit No. M12-051
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 - 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IMC -4/10
M12 -051 Printed: 04 -05 -2012
CITY OF TUKWILA'
Community Developme Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
or office use only).
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Site Address: 12048 44th PI. S.
Tenant Name: Patrick K. and Desiree A. Kalalau
Property Owners Name: Patrick K. and Desiree A. Kalalau
Mailing Address: 12048 44th PI. S.
King Co Assessor's Tax No.: 3347400860
Suite Number: Floor:
New Tenant: ❑ Yes 0..No
Tukwila
WA
98178
City
CONTACT: PERSON - who do we contact when your permit is ready tobe issue
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
State
Zip
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION • (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City
Day Telephone:
Fax Number:
Expiration Date:
Contact Person:
E -Mail Address:
Contractor Registration Number:
State
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State Zip
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
;ENGINEER OF RECORD'= All plans must be•wet stamped by Engineer of Recor
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
H:Wpplicat ions \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 1 of 6
BUILDING PERMIT. INFORMAT ION .:= ,206= 431- 3670
Valuation of Project (contractor's bid price): $ 26,689 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
®.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areasin Square Footage Below
Interior Remodel
:'.. :Addition toy;:;
Existing
.. ':Structure .
'onstruction per
: IBC
Type of
Occupancy per
IBC
1` Floor.;
1,310
2nd Floor;
3` 'Floor'
Floors: ' thru;;
Basement
Accessory_Structure*
=Attached Garage
•
Detached Garage = s
:Attached'Carpo. •
'Detached Carport
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fotms- Applications On Line \2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
MECHANICAL PERMIT INFO ATION - 206 -431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Mechanical work (contractor's bid price): $ S 9 R- D
Scope of Work (please provide detailed information):
Use: Residential: New .... ❑ Replacement .... ❑
Commercial: New .... ❑ Replacement .... ❑
Fuel Type: Electric ❑ Gas .... ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace>100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
I
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
Incinerator - Domestic
Other Mechanical
Equipment
Air Handling Unit
<10,000 CFM
Incinerator — Comm/Ind
H: Applications \Forms - Applications On 1ine\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
• bh
Page 4 of 6
J
PUBLIC; WORKS PERMITIN1 MATION - 206 -433 -0179
Scope of Work (please provide detailed information):
Call before you Dig: 1- 800 -424 -5555
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑ ...Tukwila ❑...Water District #125
❑....Water Availability Provided
Sewer District
❑ ...Tukwila
❑ ...Sewer Use Certificate
Septic System:
jl On -site Septic System — For -site septic system, provide 2 copies of a current septic to approved by King County Health Department.
❑ .. Highline
0... Valley View ❑ .. Renton
❑...Sewer Availability Provided
❑ .. Renton
❑ .. Seattle
Submitted with Application (mar t oxes which apply):
❑ ...Civil Plans (Maximum Paper . e — 22" x 34 ") .
❑...Technical Information Report (Sto Drainage) ❑ .. Geotec 1 Report . ❑...Traffic Impact Analysis
❑ ...Bond ❑ .. Insurance �'s ❑ .. Easement(s) ❑ .. Maint ce Agreement(s) 0... Hold Harmless — (SAO)
❑...Hold Harmless — (ROW)
Proposed Activities (mark boxes that apply):
❑ ...Right -of -way Use - Nonprofit for less than 7'S ours ❑ . t+ ght -of -way Use - Profit for less than 72 hours
❑ ...Right -of -way Use - No Disturbance ❑ r ' 'ght -of -way Use — Potential Disturbance
❑ ...Construction/Excavation/Fill - Right -of -way ❑
Non Right -of -way
❑ ...Total Cut
❑ ...Total Fill
cubic yards
cubic yards
❑ .. Work in Flood Zone
❑ .. Storm Drainage
❑ ...Sanitary Side Sewer ❑ .. Abando eptic y : k ❑ .. Grease Interceptor
❑ ...Cap or Remove Utilities ❑ .. Curb s • t '
�; ❑ .. Channelization
❑ ...Frontage Improvements ❑ Pav- ent Cut ❑ .. Trench Excavation
❑ ...Traffic Control ❑ .. Lo o e ed Fire Line ❑ .. Utility Undergrounding
❑ ...Backflow Prevention - Fire Protection
Irrigation "
Domestic Water
❑ ...Permanent Water Meter Size... 2, WO #
❑ ...Temporary Water Meter Size .. WO #
❑ ...Water Only Meter Size WO # ❑ ... Deduct �°t.. ter Meter Size
❑ ...Sewer Main Extension Public ❑ Private ❑
❑...Water Main Extension Public ❑ Private ❑
FINANCE INFORMATION
Fire Line Size at Property Line
❑ ...Water ❑ ...Sewer
Monthly Service Billing to:
Name:
Number of Public Fire Hydrant(s)
❑ ...Sewage Treatment
Day Telephone:
Mailing Address:
State Zip
Water Meter Refund/Billing:
Name:
Mailing Address:
City
Day Telephone:
City
State Zip
H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 3 of 6
PERMIT, APPLICATION NOTi Applicable to all permits in this ication
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED
Signature:
Print Name:
Timothy J. Fenl. son, SM Ste p r Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Date: ' f Z
Day Telephone: (206) 624 -2777
Seattle WA 98106
City
State
Zip
Date Application Accepted:
Date Application Expires:
Staff Initials:
H:Wpplicat ions \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
RMIT INFORMATION.'- 206=43
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Intl Building Code):
Occupancy (per Intl Building Code):
Utility Purveyor: Water:
er:
Indicate type of plumbing fixtures and/or gas piping outlets ing insta and the quantity below:
Fixture
Qty
Fixture Type:
Q
F' : ure Type: `
Qty `
Fixture Type'
Qty'
oTcombination
bath/shower
othes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain ord
water cooler (per head)
-waste grinder,
co i ercial
Floor Drain
Shower, single head trap
Lavatory
Was'k I ountain
Receptor, indirect waste
Sinks
Urinals
Water 0 4 set
Building sewer and each
trailer park sewer
Rain water system = per
drain (inside building)
Water heater and/o ; = nt
Industrial to treatment
interceptor, I luding trap
and vent, exct�for kitchen
type grease int eptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or a - ation of
water pip',. _ and/or water
treatme :. equipment
Repair or alterati of
drainage or vent ping
Medical gas piping
system serving 1 -5
inlets/outlets for a
specific gas
Each additional medical
gas inlets /outlets greater
than 5
Ba ow protective
. ce other than
ospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:\Applications \Forms - Applications On- Line\2009 Applications \I -2009 Permit Application.doc
Revised: 1 -2009
bh
Page 5' of 6
Citillof Tukwila,
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: //www. ci. tukwila. wa. us
SET RECEIPT
RECEIPT NO: R12 -01243
Initials: WER
Payment Date: 04/05/2012
User ID: 1655 Total Payment: 6,715.15
Payee: PAMELA K KUEHL (PHONE)
SET ID: 033012 SET NAME: KING COUNTY HOUSING AGAIN
SET TRANSACTIONS:
Set Member Amount
D12 -099 229.85
D12 -100 220.30
D12 -101 334.07
D12 -102 304.27
D12 -103 191.65
D12 -104 228.20
D12 -105 326.62
D12 -106 210.75
D12 -107 210.50
D12 -108 220.30
D12 -109 311.72
D12 -110 172.55
D12 -111 248.95
D12 -112 419.17
D12 -113 503.80
M12 -041 167.70
M12 -042 167.70
M12 -043 177.10
M12 -044 167.70
M12 -045 167.70
M12 -046 167.70
M12 -047 167.70
M12 -048 167.70
M12 -049 167.70
M12 -050 167.70
mormarmastaramist, ,
M12 -052 167.70
M12 -053 167.70
M12 -054 167.70
M12 -055 225.25
TC TATS! 229.85
Citi of Tukwila, •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: //www. ci. tukwila. wa. us
TRANSACTION LIST:
Type Method Description
Amount
Payment Credit C VISA
ACCOUNT ITEM LIST:
Description
TOTAL:
6,715.15
6,715.15
Account Code Current Pmts
BUILDING - RES
MECHANICAL - RES
STATE BUILDING SURCHARGE
000.322.100
000.322.102.00.0
640.237.114
TOTAL:
4,065.20
2,582.45
67.50
6,715.15
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
/1.7 2 -6S7
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
16A1-4 % nW /RES
Type of'Inspection:
J/ •✓4 L
Address:
/20 yP ys/ rrI
S
Date Called:
r.
Special Instructions:
f
Date Wanted :.
-- / — %
Cdr
P.m.
Requester:
Phone No.
-sV. c— 3� 7_..
I
4/8 a7
''.1;ti
Approved per applicable codes.
CO MENTS:
Corrections required prior to approval.
V\-1 C've.
Ingpectd :
Dat
Ca-
REINSPECTION FEE REQUIRED. Prior to ext inspection. fee must be
pa
./ at 6300 SoufhcenterIBlvd., Suite 100. Call to schedule reinspection.
ir
. 1,,,"
• r+Etil� liUPI►�
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M12 -051
PROJECT NAME: KALALAU RESIDENCE
SITE ADDRESS: 12048 44 PL S
X Original Plan Submittal Response to Incomplete Letter #
DATE: 03 -30 -12
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
ling Divlslon
Public Works ❑
Fire Prevention
Structural
n
Planning Division
n Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
DUE DATE: 04 -03 -12
Complete Incomplete n Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
n
Approved with Conditions
DUE DATE: 05-01 -12
Not Approved (attach comments) ❑
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Piper Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with Lai to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCCI9190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135931
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
5
Landmark
American Ins Co
LHA135931
03/01/2012
03/01/2013
$1,000,000.0003
/06/2012
3
Landmark
American Ins Co
LHA135245
03/01/2011
03/01/2012
$1,000,000.00
03/07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.00
03/10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01/2009
03/01/2010
$1,000,000.0008
/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
04/05/2012
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
Cw
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
w
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
OR XX
0
X/Y
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
1p
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 BASEMENT AND MAIN FLOOR MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS. DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
6.
7.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
10.
11.
12.
PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
REVISIONS
No changes shall be made to the scope
cif work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
SYMBOL
SG—X XX
I--DN I +
UPI + UP
DN
+ f +
■
VD
RA /EA
RG
SA
SA
RA /EA
SD
EA
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION — RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
OR ® THERMOSTAT
EQUIP ID` \ EQUIPMENT LOCATION
— t MOD
NG NG
3
0
•
D'4
J
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
REMARKS
DESCRIPTION
VOLTS
PH
337
<.08 "WG
7'10
EXTERIOR
15
16
15
16
N/A
15
16
N/A
—
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
—
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 — DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
LOCATION
REMARKS
WC -1
EXTERIOR
90
337
<.08 "WG
7'10
EXTERIOR
1,2
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1833
1456
3
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE (NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 01011 AND 02080 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
FILE COPY
Permit No.
Plan review approval is sublet to errors and omissions.
Of construction documents does not aurtherin
t .3:ation of any adopted code or ordinance. Receipt
i proved Fr ='..,, .`, cofcItans is acknowledged:
0
i�
• 'r
By
D
City Of Tlukwila
BUILDING DIVISION
SEPARATE PERMIT
REQUIRED FOR
❑ Meichankai
lectrical
Plumbing
C3as Piping
City of Tukwila
BuRPTIO DIVISION
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 0 4 2012
VY1�-
City of Tukwila
BUILDING DIVISION
MECHANICAL VENTILATION CALCULATION RECEIVED
PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) la
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1,(2.
QF = 45 / (1 X 1/2) = 90 CFM
MAR 3 0 2012
PERMITCENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional Limited liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98108
(808) 824 -2777 • FAX (208) 824 -2979
THE GREENBUSCH GROUP, INC
)))
NANO a IEnlwac L 01162201021
1001210 98f If OWE 201 SOME. it 88119
(208) 378- 0889 (208) 378 -0841 FAX
0810.03.1 833
0
ID
-J
z
0
ckf
z
W
z
z
0
0
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED
BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1833
:3::::;-.i--. SEE
BEDROOM
3 (E)SG
(E)SG
BEDROOM
2
BASEMENT MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
CEILING
1)
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN.
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
MOD, INTERLOCK
TO FURNACE
POC
FLOOR
J
0
0
V)
w
FURNACE
OUTSIDE AIR TO FURNACE ELEVATION
SCALE: NONE
NORTH
24' x 24' EXIST.
ATTIC ACCESS
PANEL
COVERED
DECK
N
GAS
METER
(E1SG
BEDROOM
BATH 1
[21 (E)RG
LIVING
ROOM
DIMING
ROOM
KITCHEN
CARPORT
ROOF
1
1
2
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLAN
CAULK
FOAM BACKER ROD
WALL CAP
SLEEVE AND ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL.
WALL CAP CONNECTION DETAIL
SCALE: NONE
NORTH
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE
SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10
FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING
MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE
HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY,
INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE
WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51 -52- 0403.8.2
(CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL
BE CAPABLE OF OPERATING THE VENTILATION SYSTEM
WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES).
COORDINATE FINAL TIME SETTING WITH PROJECT
REPRESENTATIVE.
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP.
REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4
COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER WAC 51- 52- 0403.8.2 -5.8.
INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4
FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2.
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING
FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR
BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED
VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR
TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY
BE REUSED.
05
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 0 4 2012
City of Tukwila
!WILDING DIVISION
RECEIVED
MAR 30 2012
PERMIT CENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, RA 98106
(200) 624 -2777 • FAE (206) 624 -2973
THE GREENBUSCH GROUP, INC
)))
vEf IL7al i sill' lE so 100LE. O1A IN 10119
(206) 370 -0669 (206) 370 -0641 FAX
0810.03.1833
C/)
1—
z
w
w
o O
0 o:
a.
Et 2
—1
‹
0
Q
Z
w
z E
V
co
KING COUNTY
AIP NUMBER
5 -53 -0058 -043
z
0
H
z
Cn
w
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
BASEMENT
AND MAIN
FLOOR
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.1833