Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M12-053 - MILLER RESIDENCE
MIT.I,FR RESIDENCE 11803 44 AV S M12 -053 City oPii'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 3347400565 Address: 11803 44 AV S TUKW Project Name: MILLER RESIDENCE Permit Number: M12 -053 Issue Date: 04/05/2012 Permit Expires On: 10/02/2012 Owner: Name: MILLER GARTH Z Address: 11803 44TH AVE S , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Email: SHARYN.PARKER @KINGCOUNTY.GOV Phone: 206 - 296 -7437 Contractor: Name: Ttfdv' COv,.bfvu 4' ov /� ,d Phone: Address: 2_Z c" %J MAYOs 41/ V-reSpo c i Contractor License No: ► W A' CC r `R o ^' Expiration Date: DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Mechanical: $1,749.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $167.70 International Mechanical Code Edition: 2009 Date: A - I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Date: % /67/Z This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -053 Printed: 04 -05 -2012 PERMIT CONDITIONS Permit No. M12-053 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate pe tni sued by the City of Tukwila Building Department (206- 431- 3670). 1 "� ' ` .1.01, 1 • .01t1:0 9: All electrical work shall be inspected and approved under a separ tte p2rrnit isi ueclrby the City of Tukwila Building Department (206- 431 - 3670). T ' 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12-053 Printed: 04 -05 -2012 CITY OF TUKWILA Community Developm•Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.imus Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 11803 44th Ave. S. Tenant Name: Garth Z. Miller Property Owners Name: Garth Z. Miller King Co Assessor's Tax No.: 3347400565 Suite Number: Floor: New Tenant: ❑ Yes m ..No Mailing Address: 11803 44th Ave. S. Tukwila WA 98178 City State Zip CONTACTPERSO o do we contact when'your permit is ready to be, issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR' INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD ; All plans must be wet stamped by Architect'ofRecord Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H:\Applications \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT: INFORMATION 206 -431 -3670 Valuation of Project (contractor's bid pri . $ 20,710 Existing lding Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below st Interior Remodel 'Addition ;to Existing;'' Stractuie. Type of Construction per: IBC•. . :1. Type.of ;::.: Occu pancy per IBC 870 2' Floor Floor: 'Floors Basement •: Accessory S4-uct-Lire' Attached . Carport ; :Deiach`ed, Carport; Covered Deck Uncovered Deck:. PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ ' No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Fotms- Applications On Line \2009 Applications \1-2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 MECHANICAL PERMIT. INFORMATION _ 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Mechanical work (contractor's bid price): $ 67 4 - © 0 Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>!00K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System j ` Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind H:\Applications\Fotms- Applications On Line\2009 Applications \I -2009 - Petmit Application.doc Revised: 1 -2009 bh Page 4 of 6 PUBLIC WORKS PERMIT INFORMATION =.206 -433 -0179 Scope of Work (please provide detailed information): Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Se tic System: D On -site Septic System — n -site septic system, provide 2 copies of a current septic design ap Submitted with A r • licatlon mar .I oxes which a . 1 ❑ ...Civil Plans (Maximum Paper `ye — 22" x 34") ❑ ...Technical Information Report (Sto I Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ -. Highline 0... Valley View ❑ .. Renton ❑ ... Sewer Availability Provided Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 ho ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ - ..Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Renton ❑ .. Seattle by King County Health Department. ❑ .. Geotechnical R ,:rt ❑ .. Maintenance greement(s) ❑ ... Traffic Impact Analysis ❑ ... Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) ❑ .. RigIpof- -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance cubic yards cubic yards ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public .. Work in Flood Zone Storm Drainage ❑ .. Abandon S ptic Tank ❑.. Curb Cu ❑ .. Pavempttt Cut El.. Loop -d Fire Line El l WO # WO # WO # 0...Deduct Water j - Size Private ❑ Private ❑ ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to:. Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 3 of 6 'PERMIT ::APPLICATIONNOT • Applicable to all permits in this aication :;: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED Signature: Print Name: Timothy J. Fe • IV.,"!." eV Mailing Address: 4000 Delridge Way SW, Suite 200 son, SM Ste er Architects, PLLC Date: WCIA. 20 l Day Telephone: (206) 624 -2777 Seattle WA 98106 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\Applications \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING AND 'GAS' PIPIN ERMIT INFORMATION -:'106;441670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: not yet awarded City Contact Person: • Day Telephone: E -Mail Address: Fax Number: State Zip Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: wer: Indicate type of plumbing fixtures and/or gas piping outlets b ed and the quantity below: Fixture Type: '' Qty Fixture Type: :..:. Qty ',iy 'ture Type: Qty .. Fixture Types ° Qh' Bathtub or combination bath/shower Bidet ' CI es washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -w a grinder, commercia Floor Drain Shower, single head trap Lavatory Wash fountai Receptor, indirect waste Sinks Urinals Water Closet �, Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Rain water system— per drain (inside building) Water heater a r vent - Industrial waste treatm interceptor, including trap and vent, except for kitchen type grease interceptors Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair s; k alteration of water ,a "sing and/or water trea R+ ent equipment Repair or alteration of drainage or vent piping X Medical gas piping system serving 1 -5 'inlets/outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 = : ckflow protective %i evice other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:Wpplications \Forms - Applications On-Line \2009 Applications \1-2009 Permit Application.doc Revised: 1-2009 bh Page 5 of 6 CitOof Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -01243 Initials: WER Payment Date: 04/05/2012 User ID: 1655 Total Payment: 6,715.15 Payee: PAMELA K KUEHL (PHONE) SET ID: 033012 SET NAME: KING COUNTY HOUSING AGAIN SET TRANSACTIONS: Set Member Amount D12 -099 229.85 D12 -100 220.30 D12 -101 334.07 D12 -102 304.27 D12 -103 191.65 D12 -104 228.20 D12 -105 326.62 D12 -106 210.75 D12 -107 210.50 D12 -108 220.30 D12 -109 311.72 D12 -110 172.55 D12 -111 248.95 D12 -112 419.17 D12 -113 503.80 M12 -041 167.70 M12 -042 167.70 M12 -043 177.10 M12 -044 167.70 M12 -045 167.70 M12 -046 167.70 M12 -047 167.70 M12 -048 167.70 M12 -049 167.70 M12 -050 167.70 M12 -051 167.70 M12 -052 167.70 M�12 -053 1647.70 M12 -054 167.70 M12 -055 225.25 TOTAL. 229.85 Cit. of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukw ila. wa. us TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA ACCOUNT ITEM LIST: Description TOTAL: 6,715.15 6,715.15 Account Code Current Pmts BUILDING - RES MECHANICAL - RES STATE BUILDING SURCHARGE 000.322.100 000.322.102.00.0 640.237.114 TOTAL: 4,065.20 2,582.45 67.50 6,715.15 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 z (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 �= /1'2,2-o5 Project: /Y/ /GL (2 RI S Type of Inspection: `, A✓. 1., - . �1, Address: /4630 3 yy v 5 Date Called: Special Instructions: Date Wanted:. 4 - ' - r z a.m. Requester: Phone No: _-s5ci -,_ 6 7 - '/ 327 Approved per applicable codes. ' Corrections required prior to approval. 1 COMMENTS: / ) 'n t A - / - . �1, )744-z,, N Inspector: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: / i — [ Z- � r ettalii CO COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -053 PROJECT NAME: MILLER RESIDENCE SITE ADDRESS: 11803 44 AV S X Original Plan Submittal Response to Incomplete Letter # DATE: 03 -30 -12 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 4ANJL u' (Idingiviision Public Works ❑ Fire Prevention Structural n Planning Division Permit Coordinator U DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04-03-12 Complete Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route LCILI Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved 111 Approved with Conditions Not Approved (attach comments) Ti Notation: EP REVIEWER'S INITIALS: DATE: DUE DATE: 05 -01 -12 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pf er Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135931 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Landmark American Ins Co LHA135931 03/01/2012 03/01/2013 $1,000,000.0003 /06/2012 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.00 03/07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.0003 /10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.0008 /05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/Ini/bbip/Print.aspx 04/05/2012 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN M TG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STA11C PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STA11C PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR OR XX 0 X/Y DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN AND UPPER FLOOR MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WIN ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' —O" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 6. 7. 10. 11. 12. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SYMBOL $G X XXX + r + "h■ -+y[SI -el— e-- EQUIP ID #�._ R NG • 3 0 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD VOLUME DAMPER RA /EA RETURN AIR OR EXHAUST AIR DUCT RG RETURN AIR GRILLE SA SA RA /EA SD SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION — RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X 25 1,2 — SWITCHES (ON, TIMER) 120 1 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN X X 1 REMARKS: 1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 — DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 165 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH ` SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 3 SG -1 165 <.08" WG 8" 8" CEILING DECO 1, 2, 3 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" CEILING DECO 1, 2, 3 RG -2 25 <.08" WG 4" 4" WALL DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1835 1331 3 90 CFM 90 CFM IN CEMENT SLAB OR IN GROUND 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51- 1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION I MIN VALUE INOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. FILE COPY Permit No. r view approval is subject to errors and omissions, of construction documents does not sulfate i .3 ufson of any adopted pted «q se or ordinance. Kempf a 4proved Fiel J =t Is acknowledged By Date: ;,_NI r// 2 City Of lUkwita BUILDING DIVISION THERMOSTAT /SWITCH HOURS OF OPERATION SEPARATE PERMIT REQUIRED FOR ❑ Mechanical [electrical ErPlumbing Was Piping City of Tukwila BUILDING DIVISION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 ,F Y City of Tukwila BUILDING DIVISION MECHANICAL VENTILATION CALCULATION RECEIVED PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / ( &EGR X F) QR = (FROM TABLE 403.8.1) la &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF =45/(1 X1 /2) =90CFM MAR 3 0 2012 PERMITCENTER M EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Profeeelouo.l limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, w& 98106 (600) 6B4 -2779 • FAX (20e) 624 -2973 THE GREENBUSCH GROUP, INC 900 i i SAU w 3 u W0 0 Eirl0 Y (206) 376 -0509 (200) 378 -0041 FAX 0810.03.1835 KING COUNTY INTERNATIONAL AIRPORT F- z w 2 w 0 0 0 w w w 0) 0 0 z F- J w AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT. ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1835 GAS METER KITCHEN D IN ING ROOM ALL GRILLES 4 "0, CONTINUED ON 2/M2.0 (E) LIGHT 6 LIVING ROOM CEILING GRILLES !BEDROOM 2 MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS OUTSIDE AIR DUCT 16" MIN RETURN AIR DUCT FILTERS ACCESS MOTOR ACCESS HOLD TIGHT TO STRUCTURE COORDINATE ACCESS HATCH FOR ELECTRICA AND MAINTENANCE ACCESS WITH TECHNIC L REPRESENTATIVE ATTI C NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL NONE NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1 /A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL NONE 25 4"0, CONTINUED ON 1/M2.0 BEDROOM 3 UPPER FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE DUCT PER PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE CAULK FOAM BACKER ROD ARCHITECT TO PROVIDE 2X4 BLOCKING TO SUPPORT CEILING CUTTING FLOOR OR CEILING JOIST CEILING SLEEVE AND ESCUTCHEON GRILLE NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUC11ONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL NONE NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DRAWING NOTES: FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 2. HEATING IS PROVIDED BY ELECTRIC UNIT HEATERS. FLAG NOTES: BV-1 AND DUCTWORK ROUTED IN ATTIC. COORDINATE MAINTENANCE HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. CUT AND PATCH CEILING AS REQUIRED TO INSTALL RETURN AIR DUCT AND GRILLE IN BEDROOM 2. DUCT PER PLAN CAULK FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. Hl2OS3 WALL GRILLE INSTALLATION DETAIL NONE RECEIVED MAR 30 2012 PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Profeeatonal Limited Liability company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 1324 -27?? • FAX (206) 624 -217 THE GREENBUSCH GROUP, INC ))) MIlD NDEO da 141aW409L Q1024:0161D 190D SBL SI i S1EIE 901 SfJiIIIZ SA N119 (206) 376 -0650 $200) 378 -0941 FAX 0810.03.1835 KING COUNTY INTERNATIONAL AIRPORT z w w 0 a 0 w w w 0 ce z D Cn W AIP NUMBER 5-53-0058-043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA MAIN AND UPPER FLOOR MECHANICAL PLANS AND DETAILS M2.0 0810.03.1835