Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M12-067 - WESTFIELD SOUTHCENTER MALL - THE ART OF SHAVING
THE ART OF SHAVING 201 SOUTHCENTER MALI. M12 -067 City 4lTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 201 SOUTHCENTER MALL TUKW Project Name: ART OF SHAVING, THE Permit Number: M12 -067 Issue Date: 05/24/2012 Permit Expires On: 11/20/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: PHILIP FOSTER Address: 219 N 2 ST, STE 301 , MINNEAPOLIS MN 55401 Email: PFOSTER @CMARCH.COM Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST , SEATTLE WA 98108 Contractor License No: EVERGRL954R2 Phone: 612 338 -6677 Phone: 206 763 -1744 Expiration Date: 01/06/2014 DESCRIPTION OF WORK: EXISTING FAN COIL UNIT AND ASSOCIATED CONDENSING UNIT TO REMAIN IN SERVICE. INSTALL NEW DISTRIBUTION DUCTWORK AND DIFFUSERS. EXISTING TOILET ROOM EXHAUST FAN TO REMAIN IN SERVICE. Value of Mechanical: $20,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $428.56 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: ►J-�' Print Name: Ait.11 By, ttluv- Date: 5 214 ( 2 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -067 Printed: 05 -24 -2012 • • PERMIT CONDITIONS Permit No. M12-067 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12-067 Printed: 05 -24 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. MVL l Project No. Date Application Accepted: 0,-(1)117, Date Application Expires: tot '1)1(i- (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: Aouthcenter Mall King Co Assessor's Tax No.: - l //v!''11 00i 0 Suite Number: 632 Tenant Name: The Art of Shaving PROPERTY OWNER Name: Philip Foster Address: 219 North 2nd Street, Suite 301 Name: Westfield Phone: (612) 338 -6677 Fax: (612) 338 -2995 Email: pfoster @cmarch.com Address: 2800 Southcenter City: Seattle State: WA zip: 98188 CONTACT PERSON - person receiving all project communication Name: Philip Foster Address: 219 North 2nd Street, Suite 301 City: Minneapolis State: MN Zip: 55401 Phone: (612) 338 -6677 Fax: (612) 338 -2995 Email: pfoster @cmarch.com Floor: 1 New Tenant: m Yes ❑..No MECHANICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail Existing fan coil unit and associate condensing unit to remain in service. Install new distribution ductwork and diffusers. Existing toilet room exhaust fan to remain in service. 20,000 Use: Residential: New ❑ Replacement Commercial: New ❑ Replacement Fuel Type: Electric Gas ❑ Other: H:Wpplications\Forns- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8 -9 -I I.docx Revised: August 2011 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 8 Floor furnace 1 Suspended/wall /floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm 8 Evaporator cooler 1 Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 8 Thermostat 1 Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMITAPPLICATION,NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDINOWNER AR AUT ORIZED AGENT: Signature: Date:OI'l/ Vo)1? Print Name Jae/ 3C477- 1?eI $T _ Day Telephone: 323 —S7f - 364/ 9 Mailing Address:2- 5 ) 60 tJT►-1 4,-7848 -- rni-l�. T1lwtc" vJA / �l/ 5' City State Zip H:\ Applications \Forms- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8- 9- 1l.docx Revised: August 2011 bh Page 2 of 2 1 • C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.zov RECEIPT Parcel No.: 9202470010 Permit Number: M12 -067 Address: 201 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/18/2012 Applicant: ART OF SHAVING, THE Issue Date: Receipt No.: R12 -01686 Initials: LAW User ID: 1632 Payment Amount: $342.85 Payment Date: 05/24/2012 12:44 PM Balance: $0.00 Payee: EVERGREEN REFRIGERATION LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 005410 342.85 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 342.85 Total: $342.85 doc: Receiot -06 Printed: 05 -24 -2012 CM, of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R12 -01358 Initials: JEM Payment Date: 04/18/2012 User ID: 1165 Total Payment: 351.40 Payee: C.M. ARCHITECTURE, P.A. SET ID: S000001738 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member EL12 -0362 M12 -067 PG12 -059 TOTAL: Amount 238.13 85.71 27.56 238.13 TRANSACTION LIST: Type Method Description Amount Payment Check 119738 351.40 TOTAL: 351.40 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 238.13 113.27 TOTAL: 351.40 INSPECTION NO. INSPECTION RECORD Retain a copy with permit M 12- 6 7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 i — (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: ARi'o Niekt]irJe Type of Inspection: FgrOAt —.. Address: A.0 ! W\ A L 1.__- Date Called: Special Instructions: Date Wanted:. % rr) 112 -6 l iZ (a.m' P.m. Requester: Phone No: nApproved per applicable codes. a Correction's required prior to approval. COMMENTS: /° 9 4/6-74 /— in/rt7 Inspect s Datei, 6///.7 RE SPECTION FEE REQUIRED. rior t next inspection, fee must be /paid at 6300 Southcenter Blvd., Su to 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. ' -CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 /'1/2- 067 Project: , ors Nf t.>r\/ d . Type of Inspection: /,am / /1— L.ti/ Address: c /() v0 0/t/ i7i9 // Date Called: Special Instructions: Date Wanted:. G — / 2 ,„ C�:%� p.m. Requester: Phone No: 0206-‘79-3/7e 'Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Inspe Co : Dat 6 -/Z EINSPECTION FEE RE( UIRED. Prior td next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. i 73 EAGLE TEST & BALANCING COMPANY AABC CERTIFIED 815 E. Main Cushing. OK 74023 Phone: (918) 225 -1668 Fax: (913) 225 -168: 13047 S. E. 47th PL. Bellevue, WA 93006 Phone: (425) 747-9256 Fax: (425) 641-5662 TEST AND BALANCE REPORT Project: AR -r of SHAY /NC, .SPACE 209 / Location: Sou-T/-iGgNiw, AIiiLG�7CL JKWIL A� "t/4 Architect. - Engineer: Contractor: Ev , ,y,REw;j1( Project Number: 667 This is to certify that Eagle Tesi & Balance has balanced the systems described herein to their optimum performance capabilities. The testing and balancing has been performed in accordance with the standard requirements and procedures of the Associated Air Balance Council and the results of these test are herein recorded. Associated Air Balance Council Certification Nuinber. 93 -02 -01 Date: Test & Balance Engineer. Stephen D. Barnes Form #89010 Project ART System INEMMIN," ..111■P" -IMMUNE.," MEV 40111411111.341C Date Page AIR DISTRIBUTION TEST SHEET Terminal Number Room Number Terminal Factor Design Test—FPM or CFM Final Type . Size FPM CFM Test 1 I Test 2 Test 3 FPM CFM Pall —/ 1 ,I. s 1) ligi.ias 1.0 .1.01) j3 Z) ) 72 ligiNtva bo 2 ib 1 2_,06 2o0 3 1 SD ye")14.4- ',O .-e, 0' 5T) I Tc -.4061 Zoo g 4. SD 318xaS )-7 .2.02) ) 4P 230 7.5,_/0 2)0 g.5.- $ R 105?S .Y6-5;7 10 0 390 1 //1 o • 1)0 \ SR Aorxr" ,114 57 )00 2-)7 I/O JOS` • 4 Remarks Form #89040 ...03181=2EV- ..4212ENEWv. ..ftEURINEV. -,dfg&gS,M4C' Project Name ART 0 WA/6 Date Page of AIR r OVING EQUIPMENT TEST SHEET Motor Sheave & No. Grooves Specified __ Actual SYSTEM Specified Actual Equipment Location . .5 .7-1R/9 GE • 1-............. Area Served 1 SP/4di.=* 2-0/ greje • Equipment Manufacturer C. ,4 m- R E • 0 0 Modet. .F-vs? If cA/F a3o Amperage _2, g 'Serial 'Number i R/A CFM E77 Motor Sheave & No. Grooves Specified __ Actual Sp-ecified Actual Specified Actual Total CFM - Fan ' 0 d 0 a/ Phase j . ' . i Total CFM - Outlet • 0 0 /0 Amperage _2, g i R/A CFM E77 8 ffe, Motor Service Factor , ME=11 0/A CFM / . .56 Total Static Pressure (Total/External) Inlet Pressure — O. 5 I 1 Discharge Pressure , [ -,- .)- a 1.2_ r 'Fan RPM . .....-_,_ i Motor Sheave & No. Grooves Specified - Actual Sp-ecified Actual 1 Motor Manufacturer Belts 1 I Motor HP/BHP //5 p,3 Phase j . ' . i Voltage Amperage _2, g Motor RPM ' 3 SPEED Motor Service Factor , ME=11 Starter Heater Elements Motor Sheave & No. Grooves D D __ Fan Sheave & No. Grooves P D Belts Remarks j2/E:Crr2E/ YE" Project Name A R7- OF . kJ/It IN EXHAUST FAN DATA SHEET Date Page SYSTEM Equipment Location GE/L. /N6- Area Served /,RES7"RaO4T Equipment Manufacturer B f /91/ Model 76 � D2 676F -�4 Serial 'number . Motor Sheave & No. Grooves Spec' ";tied . Actual Specified Actual Total CFM - Fan /A) / Z.5" 75 7_s- Phase Total CFM - Outlet 1 ` Total Static Pressure • (Total/External) /.. f Amperage O. 9' D.g _ 1 --,... Inlet Pressure Motor Service Factor — 0, 0 .2° _ Oischarge Pressure Fan RPM Motor Sheave & No. Grooves Specified Actual Motor Manufacturer ;RQ/.C%// Jig°/ -/V Motor HP /BHP ----- _ Phase 1 Voitace / )o /.. f Amperage O. 9' D.g Motor RPM --,... by _— Motor Service Factor Starter Heater Elements ----- Motor Sheave & No. Grooves `D D Fan Sheave & No. Grooves ,1 .L7 Belts 17 D Not always required or applicable. Remarks D= 1.?1> E`- "C.7- • 17F1Vf- Specified Actual • Form .489031 f PERMIT COORD COP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -067 PROJECT NAME: ART OF SHAVING, THE SITE ADDRESS: 201 SOUTHCENTER MALL DATE: 04/18/12 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: AVI- f:2 B tiding Division ® Ievention Public Works ❑ Structural ❑ Planning Division fl Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 04/19/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route 4CI INITIALS: Structural Review Required No further Review Required n DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05/17/12 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc . 02/29/12 Contractors or Tradespeople P, ter Friendly Page General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name EVERGREEN REFRIGERATION LLC UBI No. 602512953 Phone 2067631744 Status Active Address 727 S Kenyon St License No. EVERGRL954R2 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 1/6/2006 State WA Expiration Date 1/6/2014 Zip 98108 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EVERGI'201D7 EVERGREEN REFRIGERATION INC Construction Contractor General Unused 3/27/1980 '7/31/2006 01/06/2006 Re Licensed EVERGHH910J0 EVERGREEN HOME HEATING & ENGY Construction Contractor General Unused 4/20/2009 4/20/2013 Suspended Business Owner Information Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC Partner /Member 12/22/2005 Bond Amount PATTON, DAVID Partner /Member 01/06/2006 WA15097 PATTON, RODGER Partner /Member 01/06/2006 PATTON, MATTHEW Partner /Member 01/06/2006 TRAVELERS CAS & SURETY CO Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Merchants Bonding Co (Mutual) WA15097 01/01/2012 Until Cancelled $12,000.0012/15 /2011 1 TRAVELERS CAS & SURETY CO 104667361 01/01/2006 Until Cancelled $12,000.00 01/03/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 AMERICAN FIRE AND CASUALTY COM BAW54192293 07/31/2010 07/31/2012 $1,000,000.00 07/27/2011 2 Continental Western Ins Co CWP2640663 07/31/2006 07/31/2010 $1,000,000.0003 /23/2009 1 ALASKA NATIONAL INSURANCE CO 05GLS31381 07/31/2005 07/31/2006 S1,000,000.0001/03/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 05/24/2012 kobrien — 3/30/2012 1:57:06 PM K: \Projects \3292.0034 TAOS Southcenter Seottle WA \3292.0034 M1.1.dwg MECHANICAL SYMBOL LEGEND DOMESTIC COLD' WATER (CIA) 1>T(1 CONTROL VALVE (TWO -WAY) DOMESTIC HARD COLD WATER (CIA) * CONTROL VALVE (THREE -WAY) - H TEMPERED DOMESTIC HOT WATER (110' F) ii. GLOBE ANGLED VALVE -T - 120- DOMESTIC HOT WATER (120' F) • FLOW DIRECTION RECIRCULATION HOT WATER (CHW) \---I. PIPE PITCH DIRECTION SANITARY WASTE UNDERGROUND 111 PIPE UNION W SANITARY WASTE ABOVE GROUND 8 OR © IN -LINE PUMP W VENT QA AIR VENT - AUTOMATIC v III VTR VENT THRU ROOF QM AIR VENT - MANUAL .0r4 -1 hfla- RPZ VALVE (REDUCED PRESSURE BACKFLOW) G NATURAL GAS BACKFLOW PREVENTOR CHILLED WATER SUPPLY BFP CWS B BACKWATER VALVE CWR CHILLED WATER RETURN HOPPER DRAIN OR FLOOR SINK HWS HEATING WATER SUPPLY 0 o FLOOR DRAIN HWR HEATING WATER RETURN I I UNION CD CONDENSATE DRAIN PIPING S BREAK IN MATERIAL FOR VISUAL PURPOSES RL LIOUID REFRIGERANT �•n DRAIN VALVE SUCTION REFRIGERANT FINISHED FLOOR ELEVATION OT THERMOSTAT SIAMESE FIRE DEPT. CONNECTION ON THERMOSTAT - NIGHT SET BACK I e CONNECT TO EXISTING O SPACE TEMPERATURE SENSOR SUPPLY, RETURN AND EXHAUST AIR OH HUMIDISTAT MOTORIZED DAMPER CO CARBON DIOXIDE SENSOR I AQUASTAT BD BACK DRAFT DAMPER QPS PRESSURE SWITCH ( «I FIRE /SMOKE DAMPER El FLOW SWITCH @ SMOKE DAMPER TEMPERATURE GAUGE • FIRE DAMPER N.O. NORMALLY OPEN LOW -LEAK SMOKE DAMPER L N.C. NORMALLY CLOSED I-1...r OR ' VOLUME DAMPER (MANUAL) VFD VARIABLE FREQUENCY DRIVES EXHAUST REGISTER SENSOR TAP CEILING SUPPLY DIFFUSER 4 WATER HAMMER ARRESTER WITH t ' PRESSURE GAUGE WITH ISOLATION VALVE Z RETURN AIR GRILLE /REGISTER U-w^ -- RETURN AIR GRILLE /REGISTER WITH SOUND BOOT. .____40 ELBOW UP (PIPE) ELBOW DOWN (PIPE) I - SIDEWALL SUPPLY REGISTER D TEE UP -0-- Imo- SIDWALL RETURN OR EXHAUST GRILLE TEE -OFF THE BOTTOM / DOWN Y 0 FCO -140 CLEANOUT FLOOR / CEILING CLEANOUT FLOOR REGISTER ] PIPE CAP 1 ECCENTIC REDUCER LINEAR DIFFUSER Li CONCENTRIC REDUCER FLEXIBLE CONNECTION (PIPE) /**-------- FLEX DUCT P pppd O ROOF (PRV) EXHAUST FAN EXPANSION JOINT (LOOP) 1 1 PIPE ANCHOR 1 1 CABINET UNIT HEATER X ALIGNMENT GUIDES N CHECK VALVE C VAV BOX WITH COIL ICI GATE VALVE SUPPLY DUCT ELBOW WITH TURNING VANES 1).1 GAS COCK VALVE IA STOP & WASTE VALVE I STANDARD OR LINED DUCT (SUPPLY, RETURN, EXHAUST). DUCT IS LABELED TO INDICATE INTERNAL DUCT DIMENSION. SEE SPECIFICATION FOR INSULATION. (GPM) CIRCUIT BALANCING VALVE 14x10 1: 171 STRAINER STRAINER WITH BLOW DOWN 4 STANDARD ROUND TAKEOFF (CONICAL BELL MOUTH) WITH VOLUME DAMPER , e A PRESSURE REDUCING VALVE AIR FLOW MEASURING STATION AFMS PRESSURE RELIEF VALVE A GAS PRESSURE REGULATOR Kb! BALL VALVE I--I- WH WALL HYDRANT 6 BUTTERFLY /SHUT -OFF VALE I-} HB HOSE BIBB pGI GLOBE VALVE Q THERMOMETER �'`� A 1 Nd OS &Y VALVE / OS &Y VALVE WIRED QFS FLOW SWITCH SOLENOID VALVE DOUBLE WALL (SUPPLY, RETURN, EXHAUST). DUCT IS LABELED TO INDICATE INTERNAL DUCT DIMENSION. CuM) FLOW MEASURING STATION __14x10. FLOW LIMITING VALVE ( - GENERAL NOTES . Work to be accomplished on these Drawings and the accompanying specifications includes the furnishing of all lobor, moteriols, equipment, and services necessory for the proper completion of all mechanical work. Before submitting o proposal on the work contemplated on these drawings and accompanying specifications, each bidder shall examine the site, check as to the means of making connections to services, and shall become familiar with all the existing conditions and limitations. No extras will be allowed because of the contractor's misunderstanding os to the omount of work involved or his lock of knowledge of ony site conditions which may affect his work. My apparent vorionce of the pion or specification from existing conditions at the site shall be called to the attention of the Engineer during the bid period so clorificotion con be mode by addendum. • Existence of any wires, conduits, pipes, ducts, or other facilities ore shown in a general woy only. It will be the duty of the contractor to visit the site and make exact determination of the existence of any such facilities prior to the submission of his bid. It is understood that he will be responsible for making the exoct determination of the location and condition of such facilities. . All required fees, permits, and inspections shall be obtoined and /or arranged for by the contractor under the section of the Specifications for which they are required. Regular inspections sholl be orronged by the contractor as required by ony and all regulations. All charges from regulating agencies for inspections of instollotions or review of plans and Specifications sholl be paid by the contractor. . Controctor to provide Certificate of Final Inspection. . All moteriols and workmanship shall comply with oil current and applicable codes, specifications, ordinonces, lows, regulations, industry stondords, and utility company regulations. . In cose of difference among building codes, specifications, stole lows, loco) ordinances, industry stondords, and utility compony regulot■ons and the Contract Documents. the most stringent shall govern. Controctor sholl promptly notify the Engineer in writing of any such difference. . All applicable federal, state, and local lows and ordinances sholl be odhered to throughout the construction project. 10. Non - Complionce. Should the contractor perform any work that does not comply with the requirements of the opplicoble building codes, state lows, local ordinances, industry stondords, and utility compony regulations, he shall bear all costs arising to correct the deficiencies. 11. Contractor shall initiate, maintain, and supervise all sofety pre - cautions required for his work, including regulations of the Occupational Safety and Health Administration (OSHA). 12. Drawings ore to scale as noted, but the contractor sholl refer to Architectural and Structural Drawings for exoct location of partitions, wolls, beoms, shafts, equipment, etc. 13. Each trade shall obtain drawings and specifications of oil other trades and coordinate his work with all other trodes. 14. Drawings show the general orrongement of ductwork, piping, equipment, and appurtenances and sholl be followed as closely as actual building construction and work of other trades will permit. Mechanical work shall conform to the requirements shown on all of the drowings. Architectural and Structural Drawings shall take precedence over Mechanical Drawings. Because of the small scole of the Mechonicol Drowings, it is not possible to indicote all offsets, fittings, and accessories that moy be required. 15. Discrepancies discovered before or of ter work has started shall be brought to the attention of the Engineer immediately, and the Engineer reserves the right to require minor changes in the work of any contractor to eliminate such discrepancies with no chonge in controct cost. 16. Plans and specifications ore complementary, and what is called for in either one shall be os binding os if coiled for in both. 17. Where a disagreement exists between the plans and specifications, the item or arrangement of better quolity, greoter quality, or higher cost shall be included in the bid. 18. Normal use of the facility sholl not be disturbed, except within the immediate construction area. All walks, driveways, and entrances shall be kept clear and free of 011 contractor's equipment, material, and debris at all times. 19. All moteriols and equipment shall be stored in such o place and in such o manner that o minimum of congestion will result. the placing of such moteriols and equipment sholl be subject to the opprovol of the owner. 20. Contractor shall thoroughly exornine the existing building with regard to whot temporary measures he must take in order to permit the owner to occupy specific areas of the building during the various construction phases. in general, systems must remain in use in those designated oreos to permit the owner to function in a pre - construction manner. 21. Each controctor sholl coordinate work with other trades in the installation of equipment, piping, conduit, and ductwork. 22. HVAC/sheet-metol controctor sholl initiate the coordinotion process by providing reproducible plan drawings showing ductwork and equipment. 23. Drawings to be forwarded to the piping contractor and electricol contractor for inclusion of their systems work. 24. Contractors shall solve all coordinotion conflicts among themselves when possible. Engineer will arbitrate when necessary, and his judgment will stand, with no additional cost to the owner. 25. Access panels shall be furnished by the trade requiring them and delivered to the general contractor for instollotion. 26. Access panels shall be as manufactured by Milcor, or approved equal, and of type the is compatible with construction and finish of the wall and /or ceiling 27. Eoch trade shall perform all cutting and patching necessary in order to perform the work, unless such work has been delegated to the general contractor /another trade. However, special permission sholl be obtained from the engineer before cutting structural members or finished moteriols. All patching shall be performed in such manner os to leave no visible trace and to return the part affected to the condition of undisturbed work. Potching work shall be performed by persons experienced, skilled, and licensed for the particular type of work involved. Inferior work will not be accepted. All holes in masonry shall be drilled with rotary drills. Impact tools shall not be used. 28. Each trode shall beor the expense of all cutting, patching, repairing, or replacing of the work of other trades required because of his foult, error, or tardiness of because of ony damage done by him. 29. Each trode shall provide all holes and openings required for his work, unless such holes and openings ore shown to be provided on the architectural or structural drowings. 30. Each trade shall remove existing work that is shown, specified, or obviously necessory for completion of his work. Owner sholl have the option of retaining ony item or material removed under this contract. Items or moteriols not retained by owner shall become the property of the trade and sholl be removed from the premises. 31. Each trade shall periodically clear away all debris, surplus moteriols, etc., resulting from his work or operations, leaving the job and the equipment furnished under any or all contracts in o clean condition. 32. Each trade shall test the equipment provided and /or installed under the specification and shall demonstrate its proper operation to the owner's operating engineer. 33. Each trade shall furnish, without additional expense to the owner, the services of competent instructors, who will give full instruction in the core, adjustment, and operation and maintenance of 011 ports of the equipment to the owner's permanent employees who are to hove charge of the equipment. 34. HVAC subcontractor shall be responsible for tested & rated fire stop systems for all thru- penetration of walls, floors Sc roof assemblies resulting from piping & other work under his controct. refer to specification section for fire stopping for requirements. 35. All wood noilers and other lumber which is instolled in concoct with metal, concrete, or masonry shall be pressure treated agoinst decoy (unless otherwise noted). REVISIONS No changes shall be made to the scope I of work without prior a ► ukwila Building approval of ; In t:: flcvsions win require 9 Division. an may include addional plan revise v fees. s. SEPARATE PERMIT REQUIRED FOR L = ctrical �ymbing tiMas Piping r'`,/ of Tukwila �' .. °-.f%G DIVISION G INDEX TO SHEETS M1.1 MECHANICAL TITLE AND SYMBOLS M1.2 MECHANICAL PLANS AND DETAILS M1.3 MECHANICAL SCHEDULES & SPECIFICATIONS REVIEWED FOR CODE COMPLIANCE APPROVED APR 2 5 2012 41- City of Tukwila BUILDING DIVISION GRILLE, REGISTER AND DIFFUSER KEY O244�0 xx6 /8DIA. 12TYP SIZE (INCHES) OR DIFFUSER NECK SIZE FM QUANTITY, NO INDICATION = 1 UNIT - DEVICE STYLE, SEE SCHEDULE NOTE: SEE GRILLE, REGISTER AND DIFFUSER SCHEDULE FOR FURTHER DETAILS. FZLE COPY Permit No., IA tot"'047 PI^ri rc viev approval is subject to errors and omissions. L:",7 of construction documents does not authorize a.atior: of any adopted code or ordinance. Receipt c' L;y?roveo Field Copy and conditions is acknowledged: By Date: 5/M /(2 City Of lbkwita BUILDING DIVISION MIT-00 BRUCE M. CARLSON architecture • planning • interior design BRUCE M. CARLSON, ARCHITECT 219 N. 2ND ST., SUITE 301 MINNEAPOLIS, MN 55401 PHONE: (612) 338 -6677 FAX: (612) 338 -2995 E -MAIL: info @cmarch.com CONTACT: PHILIP FOSTER pfoster@cmarch.com CONSULTANTS: EMANUELSON -PODAS MECHANICAL / ELECTRICAL 10401 BREN RD. EAST MINNETONKA, MN 55343 952 - 930 -0050 SCOTT VANDER HEIDEN SEAL: MICHAEL A. WEBERT SIGNATURE 03 -30 -2012 DATE ISSUED 45575 REG. NO. SOUTHCENTER MALL 632 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE: MECHANICAL TITLE SHEET REVISIONS: NO: DATE: BY: PROJECT NO: 3292.0034 DRAWN BY: RgB COPYRIGHT BRUCE M. CARLSON, AIA 2012 mcoleman — 3/30/2012 1:56:36 PM K:\Projects\3292.0034 TAOS Southcenter Seattle WA \3292.0034 M1.2.dwg r DOWN THRU SLAB FCO WASTE PIPING INSTALLED IN FURRED OUT WALL WCO SANITARY WASTE RISER DIAGRAM EWH -1 WATER RISER DIAGRAM EXIST OA DUCT TO REMAIN IF 1" SOUND INSULATION AS SPECIFIED Wiii iiiiiMiii� iii ■iii�i'rz�i�y�e iii iii�iii iiiii iw��iiiii i i�iii i. i�iii i�AI eiiii�i ii' 1 I 1 I 1 • 1 8x12 14x14 1h ) HVAC PLAN 1/4 " =1' -0" PLENUM GRILLE SIZE (SEE DRAWINGS FOR SIZE) CEILING 17z 11111111111 r RETURN AIR GRILLE PLUMBING PLAN NOTE: DIMENSION IN ( ) IS LOCATION OF PLUMBING ROUGH -IN. FIELD COORDINATE FIXTURE LOCATION PRIOR TO INSTALL. 1/4 " =1' -0" (5' + / -) 14" FLEX DUCT NOTE: SEE MECHANICAL PLANS FOR SIZE AND LOCATION OF GRILLES RETURN GRILLE DETAIL NO SCALE 1 PLENUM WITH 1/2" ACOUSTICAL LINING LINEAR DIFFUSER CEILING CONICAL BELL SPIN -IN COLLAR FLEXIBLE DUCT RUNOUT (MAX. LENGTH 5' -0 ") - 1 1 r CLAMP 1 1 1 1 1 VOLUME DAMPER —DUCT SEALER SUPPLY DUCT DRAW BAND WITH SILICONE SEALER TYP LINEAR SUPPLY DIFFUSER CONNECTION NO SCALE GENERAL NOTES CONNECTION TO EXISTING FAN COIL UNIT IS SUBJECT TO BUILDING DEPARTMENT AND LANDLORD APPROVAL. CONTRACTOR SHALL INSPECT/TEST HVAC SYSTEM FOR PROPER OPERATION AND COMPLIANCE WITH ALL CODES AND STANDARDS. PLAN NOTES O EXISTING FAN COIL UNIT AND ASSOCIATED CONDENSING UNIT ON ROOF TO REMAIN IN SERVICE. TENANT HVAC CONTRACTOR SHALL CONNECT SUPPLY AND RETURN AIR DUCTWORK TO UNIT AS INDICATED. FIELD VERIFY DUCT SIZES AND LOCATION. O PROVIDE CABLE OPERATOR FOR ALL VOLUME DAMPERS LOCATED ABOVE GYP CEILING. YOUNG REGULATOR MODEL 5020CC DAMPER WITH ACTUATOR MOUNTED IN DIFFUSER (OR EQUAL PRODUCT). O PROVIDE HAIR TRAP ASSEMBLY IN WASTE PIPING - MARBLE PRODUCTS MODEL 1701 CATCH -ALL HAIR TRAP (OR APPROVED EQUAL). O EXISTING EXHAUST FAN TO REMAIN IN SERVICE. TENANT HVAC CONTRACTOR SHALL VERIFY PROPER OPERATION AND SUBMIT DEFICIENCY REPORT TO GENERAL. CONTRACTOR IF NECESSARY. 5O PROVIDE 7 -DAY PROGRAMMABLE CONTROL FOR HVAC UNIT. COORDINATE CONTROL SYSTEM WITH LANDLORD. €:i EXISTING INSTANT ELECTRIC WATER HEATER SERVING LAV TO REMAIN IN SERVICE. TENANT PLUMBING CONTRACTOR SHALL VERIFY PROPER OPERATION AND SUBMIT DIFICIENCY REPORT TO GENERAL CONTRACTOR IF NECESSARY. 7O EWC -1 - NEW WATER CHILLER UNIT INSTALLED IN SINK CABINET. COORDINATE INSTALL WITH CABINET CONSTRUCTION. ELKAY MODEL ERS1, 1.5 GPH, 155W, 1.7 FLA, 120V/1. PH. 4:; CONTRACTOR SHALL FIELD VERIFY /LOCATE EXISTING WATER, VENT, AND WASTE PIPING AND CONNECT NEW PIPING PER APPLICABLE CODES. 9O EWH -1 - NEW WATER HEATER MOUNTED IN CABINET - COORDINATE INSTALL WITH CABINET CONSTRUCTION. EEMAX MODEL EX8208, 208V/40A, 8.3KW, 57 DEG RISE AT 1 GPM. VENTILATION SCHEDULE UNIT OCC AREA SO FT MAX CFM MIN CFM PEOPLE MIN OA SUPPLY CFM EXHAUST CFM FCU -1 800 1000 - 5 128 125 ASHRAE Standard 62.1 -2007 VENTILATION REQUIREMENT: (Rp x Pz) + (Ro x Az) = Vbz RETAIL SALES - (7.5cfm x 5 people) +(.12 x 450 sq ft) = 92 cfm OA STORAGE - (7.5cfm x 0 people) +(.12 x 300 sq ft) = 36 cfm OA FIRE SPRINKLER NOTES SPRINKLER CONTRACTOR SHALL PROVIDE IN THEIR BIDS: MODIFYING THE EXISTING SPRINKLER SYSTEM, SPRINKLER HEADS, PIPING, ACCESSORIES, ETC FOR NEW & REMOVED CEILINGS, REMOVED & NEW WALLS AND NEW LIGHT FIXTURE AND DIFFUSER LOCATIONS. PRIOR TO BID, SPRINKLER CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, MAIN & BRANCH LOCATIONS, HYDROLIC CALCULATIONS, ETC. SEE ARCHITECTURAL, ELECTRICAL, HVAC PLANS FOR ADDITIONAL INFORMATION. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. PROVIDE AS -BUILT DRAWINGS TO LANDLORD AFTER FINAL INSTALLATION. SPRINKLER CONTRACTOR TO CREATE & SUBMIT DRAWING(S) & HYDRAULIC CALCULATIONS TO BLDG DEPT AS A DEFERRED SUBMITTAL PRIOR TO START OF WORK. LOCATION OF LIGHTS, FIXTURES, AND SOFFITS TAKES PRIORITY OVER SPRINKLER HEAD LOCATION. REVIEWED FOR CODE COMPLIANCE APPROVED APR 2 2012 City of Tukwila BUILDING DIVISION MIS -oCr/ BRUCE M. CARLSON architecture • planning • interior design BRUCE M. CARLSON, ARCHITECT 219 N. 2ND ST., SUITE 301 MINNEAPOLIS, MN 55401 PHONE: (612) 338 -6677 FAX: (612) 338 -2995 E —MAIL: info@cmarch.com CONTACT: PHILIP FOSTER pfoster @cmarch.com CONSULTANTS: EMANUELSON —PODAS MECHANICAL / ELECTRICAL 10401 BREN RD. EAST MINNETONKA, MN 55343 952 - 930 -0050 SCOTT VANDER HEIDEN SEAL: MICHAEL A. WEBERT SIGNATURE 03 -30 -2012 DATE ISSUED 45575 REG. NO. SOUTHCENTER MALL 632 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE: MECHANICAL PLANS AND DETAILS REVISIONS: NO: DATE: B Y: • PROJECT NO: 3292.0034 DRAWN BY: R9B 1.2 COPYRIGHT BRUCE M. CARLSON, AIA 2012 mcolemon — 3/30/2012 1:56:08 PM mcolemon — 3/30/: K: \Projects \3292.0034 TAOS Southcenter Seottle WA \3292.0034 M1.3.dwg MECHANICAL SPECIFICATIONS 1500 CONDITIONS OF THE CONTRACT The General • and Supplementary General Conditions os previously detoils long with the general requirements listed in Division jr1 shall opply to all work of this Division. This Controctor will be required to furnish all materials and labor for a complete job if the Engineer is not informed of on omission before bids are received. 1503.1 CODES This work sholl be instolled in conformity with opplicoble Iocol ordinoces and stole statutes. All requirements of the current plumbing codes, heating and ventilation codes, energy or conservotion codes and NFPA bulletins must be met. Slondords and sizes which meet or exceed the above mentioned requirements sholl be installed os drown or specified. Nothing in the specificotions or drawings sholl be construed to permit deviotion from the requirements of governing codes. 15603.02 PERMITS /INSPECTIONS /SPECIAL CHARGES All chorges and obligotions for obtaining permits and inspections for plumbing, heoting and ventilation and fire extinguishing work sholl be the responsibility of this Contractor. This Controctor shall apply for any utility service charge, installotion or meter and gouge required and shall be responsible for the respective costs. Upon completion of the porliculor section of work the Controctor sholl furnish the Owner with proof of occeptonce from the proper Iocol or state deportment having jurisdiction. 1502.03 GUARANTEES AND TESTS This Contractor shall ossume responsibility for and defects which may develop in ony port of the systems coused by faulty workmanship, material or equipment, and agree to replace ony such foulty workmanship, material or equipment during o period of one year from dote of final occeptonce of the work without cost to Owner. All plumbing work sholl be inspected, tested and approved os required by governing codes. Tests sholl be mode in the presence of the proper inspector and the Architect or their authorized representative. All test sholl be mode by the Contractor at his own expense and he shall furnish the Architect o certificate that satisfactory tests hove been made. 1503.04 AIR AND WATER BALANCE The odjusting and balancing of the air and water flow sholl be performed by the installing Contractor (if previously certified by the NEBB or AABC or equal) or sholl be performed by on independent test and balance contractor which hos been certified by NEBB or AABC. 1506.01 INTRA- CONTRACT BOUNDARIES Cooling coil droin pons and drains from oll ventilation openings thru roof or wall shall be piped by Plumbing Controctor. For plumbing equipment which is specified under separate sections the Plumbing Controctor will be required to furnish and instoll the necessary "P" Crops, stop valves ect. including rough -in and final connections. 1506.02 ELECTRICAL SERVICE, WIRING AND ONNECTIONS The Electrical Controctor sholl provide electricol service to all motors and other mechonicol equipment (unless otherwise noted) in conformance with Div. 16 of the specifications. All wiring for the control of mechonicol motors and equipment sholl be furnished complete by the Mechonicol Contractor including but not limited to wiring, conduit, devices and installotion by o licensed Subcontractor utilizing Eleclricions experience in the type of systems to be installed. 1514.01 HANGERS & SUPPORTS Furnish and install brockets, broces or reinforcing ongles os may be required for all partitions not sufficeint in themselves to support plumbing fixtures or other wall hung equipment included in this specification. Piping suspended from contruclion above shall be hung from Grinnell Company, or equal. 1514.02 ACCESS PANELS Unless otherwise noted mechonicol items. Access panels sholl be Dry wall construction Tile ceilings on the drowings, each Mechonicol Controctor shall funish wall and ceiling access panels required Milcor, or approved, os follows: -Type M 14 "x14" minimum -Type DW 24 "x24" minimum for all 1516.01 PIPE INSULATION Cover all the following pipe types listed with premolded fiberglass pipe insulotion, 4 Ib. density and ASJ jocket. Jocket shall hove 0 perm rating of .2 and 2" cemented seams. Insulation shall hove o maximum service temperoture of 850 degrees, o UL rating, sholl meet the requirements of ASTM j✓C547, and hove o flame spreod of 25, smoke development of 50 and o fuel contribution of 50. Insulation shall hove o thermol resistance of .24 btu- in /hr -sq. ft.- degrees F, and be instolled with Zeston plenum roted covers over 1 pound density microlite blonket and 18 gouge golvonized wier of oll fittings. Molded closed cell polyethylene foon insulotion is not opproved equol. Epe. Type Domestic Cold Water Domestic Hot & Recirc Woter Pipe 1" & Less Pipe 11/4" - 2" Pipe 2 1/1" & Up Pipe 2" & Less Pipe 21/2" & Up Thickness 1/2" 1" 1" 11" 1516.03 DUCTWORK INSULATION Duct liner shall be Schuller Permocote Linocouslic or equol and approved 1 -1/2 Ib. density unless indicated to be 3 Ib. density in details on the drawings, or following porogroph's. The airstream side of the liner sholl be cooted with on immobilized EPA registered anti- microbial agent so it will not support the growth of fungus or bacteria os tested in occordonce with ASTM G21 & G22. All liner shall be cemented to the entire inside of the ductwork and secured with weld pins spoced one per each 2 squore feet on ducts 12" in width and greater. Internal liner shall be seoled of oll row edges with mastic to prevent erosion from mechonicol obrosion or air erosion. First 20 feet of supply oir duct from air handling units shall be insuloted with 1" thick ocousticol liner of 1.5 Ib. density, applied as indicoted above. First 20 feet of return oir duct from oir handling units shall be insuloted with 1" thick ocousticol liner of 1.5 Ib. density, opplied os indicated above. All exhoust ductwork within 15 feel of exhoust fon shall be insulated with 1" thick 1.5 Ib. density liner, applied os indicated above. Ductwork within 4" of drip pan shall not be Tined. All verticol relief ductwork between drip pan and roof insulation shall be insuloted with 1" thick 1.5 Ib. density fibergloss wrop. All remaining relief ductwork from drip pon to plenum shall be insuloted with 1" thick 1.5 Ib. density liner, applied as indicated obove. Ductwork within 4" of drip pon shall not be lined. All transfer duct shall be insuloted with 1" thick 1.5 Ib. density liner, opplied as indicoted obove. Ductwork within 4" of drip pon shall not be lined. All duct sizes shown on the drawings indicote free area and sheet metol sizes must be increased occordingly for insulation thickness. All fresh oir duct work and mixed air ductwork sholl be insuloted with 2" thick 3.0 Ib. density fiberglass board, secured os indicoted by the monufocturer. All supply oir ductwork not lined and run -outs to diffusers, sholl be insuloted with 1" thick 1.5 Ib. density fibergloss wrap with foil vopor borrier secured as indicated by the monufocturer. All drip pons for exhoust and relief ducts sholl be insuloted with 1" thick 1.5 Ib. density fiberglass wrop with foil vapor borrier secured as indicated by the monufocturer. 1523.01 PIPING All woter piping in the building obove ground shall be type "L" hard copper tubing with wrought copper solder type fittings, unions, etc. All water piping in the building below ground shall be type "K" soft copper and sweat fittings. Pipe and fittings shall meet ANSI H23.1. Soldered joints in copper tubing sholl be mode in strict conformance with the recommendations of the monufocturer. Cold woter line and hot woter circulating line to hot water Conk sholl be provided with o 15 degree swing check volve. Provide shut -off valves on oll branches from mains and on all connections to fixtures and equipment, on eoch &de of hot water heaters and circulating pump, and at other points indicoted on the drowings or where required for good isolation /maintenonce of the system. Water supply pipes sholl be anchored inside wall immediately behind shut -off valves to lavatories, sinks, water closets, etc. 1524 VALVES Provide boll volves as shown on plan and where required for proper operation of the plumbing system. 1525.01 VACUUM BREAKERS Vocuum breakers sholl be instolled to all fixtures with submerged inlets, Americon Standard HB -15755 chrome ploled. 1526 DOMESTIC HOT WATER Refer to equipment schedule and /or pion notes for woter heater information. 1533 PIPING (verify materials with londlord prior to instoll) All soil, woste, drain and vent piping, inside the building, shall be cost iron no -hub piping (ASTM A -888) complete with shielded couplings (ASTM C -1 277). Underground soil, waste and drain piping shall be Hub- and - Spigot cost -iron pipe and fittings (ASTM A -74 Service Class). 1534.04 ROOF CAPS Vents stocks from sewer, soil waste and droin pipes shall be extended of leost 12" above roof and shall be provided with a frost proof type of roof jocket for iron, steel, or PVC in P & G roofs. In EPDM roofs, roofer will furnish and install EDPM flashing and stainless steel draw bonds in place and woter tight on pipe. 1534.01 FLOOR DRAINS Floor drains and floor sinks sholl be Zurn, Wade, Josom, J.R. Smith or equol and opproved, with the following number referring to Josom cotolog numbers: Floor Drain X30000 -A Provide funnels on floor droins with indirect condensote. 1534.02 CLEANOUTS Provide cleonouts as shown on plan and os required by Code in oll sonitory systems. All cleonouts sholl be placed in accessible locutions to permit cleoning out of the entire systems. 1534.03 TRAPS & INDIRECT WASTES "P" traps os required sholl be provided in the droin connection from eoch fixture and piece of equipment requiring connection to the drainoge system. Except where a greose interceptor or other type of trop is specified or indicated os being required. Traps sholl conform to the requirements of the Plumbing Code. DIFFUSER, REGISTER & GRILLE SCHEDULE UNIT LOCATION MANUFACTURER MODEL SERVICE TYPE SIZE FINISH NOTES A CEILING TITUS TBDI -30-PF SUPPLY PLENUM SLOT 8" DIA, 4' LONG, (2) 1" SLOT WHITE 1 B CEILING TITUS 50F RETURN GRILLE SEE PLAN WHITE 2 C SIDEWALL TITUS 112RS SUPPLY REGISTER SEE PLAN WHITE 3 NOTES 1. ASSOCIAED CONDENSING UNIT ON ROOF TO REMAIN IN SERVICE. CARRIER MODEL 25HCA324A300, 2.5 TONS, 208V/1 PH. MECHANICAL NOTES: 1. PLENUM SLOT DIFFUSER, INSULATED. CENTER T -BAR. PROVIDE PLASTER FRAME FOR SOLID CEILING LOCATIONS. 2. CEILING RETURN GRILLE, EGGCRATE,112 "x112 "x1" 3. SIDEWALL SUPPLY REGISTER. DOUBLE DEFLECTION. 1582 DUCTWORK All duct joints and connections shop be sealed with Duro Dyne woter based duct sealer, or equal and opproved. Duct tope is NOT occeptoble. Provide Johns - Monville neoprene covered convos 1/16" thick for flexible connections between ducts and inlets and outlests of oll supply and exhoust fans and units. 1582.02 SHEETMETAL DUCTWORK All sheet metal housing, ducts and risers specified here in shall be golvonized iron, #1 grade Inland, or opproved equal, except os otherwise here in ofter specified. All flues or ducts directly connected to fans or rooms enclosing fans shall be mode in strict occordonce with the following schedules: Up to 12" in width 26 gouge 13" to 30" in width 24 gouge - 1" seam 31" to 48" in width 22 gouge - 1" seom 1582.03 SPIRAL METAL All rigid round supply ductwork shall be covered with 1" insulation wrop with foil vopor borrier. A monufoctured insulation "sock" is acceptable to pull over round ductwork and should be be secured to duct of diffuser and trunk ducts with zip ties. All above floor round ductwork shall be United Sheet Metal Co., Spirol UniSeol Duct or equal, monufoctured from galvanized steel in the following gouges: 3" diameter to 8" diameter = 26 gouge 9" diameter to 22" diameter = 26 gouge All fittings shall bve United Sheet Metal Co., Uniform or equol monufoctured with continuous welds and in the following gouges: 3" diometer to 36" diameter = 20 gouge. 1582.04 FLEX DUCT The final 5' of duct work of eoch diffuser moy of the option of the Controctor be installed with insuloted flex, Johns Monsville, Micro -Aire, J -Flex or equal and opproved. 1582.05 DUCT CLEANING Clean duct system with high power vocuum machines or high velocity forced oir to remove accumulated dust in existing (to remain) ductwork. Protect equipment with temporary filters or byposs during cleaning. 1583.01 DUCTTURNS. Elbows sholl hove o minimum throat radius of one holf of the duct width wherever possible. Elbows with o throat radius of less than one holf of the duct width sholl be provided by turning vones. Squore elbow shall be provided with Tuttle and Bailey "Ductturns , or equal and approved. 1583.02 ACCESS DOORS Provide occess doors in ducts of grovity, economizer and motorized dampers. 1584 GRILLES, REGISTERS, & DAMPERS The diffuser, register & grille schedule on the pion list Titus model Is and the following sholl be considered equol: E.H. Price, Connor, Carnes, Krueger, T &B, Noilor. All motorized domper shall be opposed blode type Pottorff, or equal and opproved series f CD -40. Furnish and install where shown on pion an opproved fire /smoke damper monufoctured by Ruskin, or opproved and equol, model #FSD -60 with 120 v octualor and Ruskin EFL(electronic fuse link). EFL shall activate upon temperature of 165'F. The EFL sholl include o push button, remote reset. Electricol sholl interlock with smoke detectors and fire olorm system. 1588 EXHAUST & GRAVITY AIR UNITS Cook, Carves, Jenn Air, Bailey, Powerline, Twin City Fon & Blower, Greenheck, shall be considered approved equals. 1590 AUTOMATIC TEMPERATURE CONTROL SYSTEM A 24 volt system of electric /electronic controls, properly interfaced, sholl be furnished os a port of the complete HVAC system and installed by the Heoting/Ventiloting /Air Conditioning Controctor. This Controctor sholl furnish and install low voltage wiring between control devices and equipment. Wiring moy be installed without conduit except where required for mechanical protection or plenum conditions. Conduit where required shall be furnished by the Mechonicol Controctor unless noted on the drawings to be installed by the Electricol Controctor. All conduit shall be instolled in a timely monner to be completely conceoled in finished spaces. In unfinished spaces, conduit shall be thin wall, instolled in o neot and sturdy manner. Wiring shall conform to NEC Article 725, Class 1 and 2 requirements and shall be neatly cabled and tied to building construction of maximum of 10 foot intervols. The control system shall be o Honeywell Commerical Vison Pro 8000 or equol and opproved progromoble thermostot and components complete with 7 day feature coboble of setting bock the temperoture of both heating and cooling modes, digital readout, and switch For intermittent or constont blower. PLUMBING FIXTURE SCHEDULE UNIT FIXTURE LOCAL CONNECTIONS NOTES WASTE (IN) VENT (IN) CW (IN) HW (IN) S-1 BARBER DEMO SINK 1 1/4 1 1/2 1/2 1/2 1 FCU -1 STORAGE CARRIER FX4CNF030 HORIZ 30 FIELD VERIFY FIELD VERIFY 1,000 1/3 208/1 1 MECHANICAL NOTES: 1. SINK, FAUCET, AND ACCESSORIES FURNISHED BY OWNER. EXISTING FAN COIL UNIT - DX SCHEDULE UNIT LOCATION MANUFACTURER MODEL TYPE COOLING DATA HEATING DATA FAN DATA NOTES TOTAL CAPACITY (MBH) REFRIGERANT TYPE CAPACITY (MBH) AIRFLOW (CFM) POWER (HP) VOLTAGE/ PHASE FCU -1 STORAGE CARRIER FX4CNF030 HORIZ 30 FIELD VERIFY FIELD VERIFY 1,000 1/3 208/1 1 NOTES 1. ASSOCIAED CONDENSING UNIT ON ROOF TO REMAIN IN SERVICE. CARRIER MODEL 25HCA324A300, 2.5 TONS, 208V/1 PH. o (pi REVIEWED FOR CODE COMPLIANCE APPROVED APR 2 2012 City of Tukwila BUILDING DIVISION BRUCE M • CARLSON architecture • planning • interior design BRUCE M. CARLSON, ARCHITECT 219 N. 2ND ST., SUITE 301 MINNEAPOLIS, MN 55401 PHONE: (612) 338 -6677 FAX: (612) 338 -2995 E -MAIL: info @cmarch.com CONTACT: PHILIP FOSTER pfoster ©cmarch.com CONSULTANTS: EMANUELSON -PODAS MECHANICAL / ELECTRICAL 10401 BREN RD. EAST MINNETONKA, MN 55343 952 - 930 -0050 SCOTT VANDER HEIDEN SEAL: MICHAEL A. WEBERT SIGNATURE 03 -30 -2012 DATE ISSUED 45575 REG. NO. SOUTHCENTER MALL 632 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE: MECHANICAL SCHEDULES AND SPECIFICATIONS REVISIONS: NO: DATE: BY: PROJECT NO: 3292.0034 DRAWN BY: RgB 1 .3 COPYRIGHT BRUCE M. CARLSON, AIA 2012