Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M12-072 - KISSINGER BUILDING
KISSINGER BUILDING 5219 S 144 ST M12 -072 City olkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.Tukwila WA .gov MECHANICAL PERMIT Parcel No.: 7999600066 Address: 5219 S 144 ST TUKW Project Name: KISSINGER BUILDING Permit Number: M12 -072 Issue Date: 12/05/2012 Permit Expires On: 06/03/2013 Owner: Name: KISSINGER R & T TRUST U/A Address: KISSINGER R & T TRUSTEES , 14415 53RD AVE S 98168 Contact Person: Name: LANCE KISSINGER Phone: 206 - 228 -4033 Address: 12216 11 AV NW , SEATTLE WA 98177 Email: Contractor: Name: RANGER HEATING & COOLING LLC Address: 4014 61 AV S , FIFE WA 98424 Contractor License No: RANGEHC905OM Phone: 206 913 -1123 Expiration Date: 09/18/2014 DESCRIPTION OF WORK: INSTALL NEW TRANS 4 -TON PACKAGE UNIT WITH 15 VIW STRIP HEAT. HEAT PUMP AND NEW DUCT WORK. RUN IN EXPOSED SPIRAL (9) SUPPLY RUNS (1) RETURN AIR WITH ECONOMIZER. Value of Mechanical: $8,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: tiff Fees Collected: $281.56 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Cgti Ul L-, y. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: /p` - (Inn. IMf: -4/1n M12 -072 PrintarI 17- nr, -2n12 • • PERMIT CONDITIONS Permit No. M12 -072 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. Mr.. IMn -4/10 M12-072 Prinmprl 17 -ns -7017 CITY OF TUKWIJ Community Developme partment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov V Date Application, Accepted ,1 Date Application' Expires: (For ofce use Only): 1. MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** � Site Address: SR 1 el / S• Gb. King Co Assessor's Tax No.: 1°161(1 Leo— (o Suite Number: Floor: Tenant Name: New Tenant: ❑ Yes X. No PROPERTY..UWNER'.; Addre .: State: kJ, EA Zip: co-7 '" CONTACT ,PERSON person recewmg all project communication. �i. :: r Company Name: Raler/tiecif 9 Name: 11 11 1 K I / I 11 ddress: City: State: Zip: Phone: µ�� 2 �r j 2- 4 /i !� V : Email: :,MECHANICAL:;CONTRACTOR INFORMATION: Company Name: Raler/tiecif 9 Address: L +l� 16IA-Ave City: 1 ac u State: j Zipq gt/ /L/ Phone: D 53 ,* _5760 Fax:; 53_,2q _QOO I Contr Reg No.: R 4 xi 0050141 Exp Date: 3 .1 joic( J Tukwila Business License No.: Valuation of project (contractor's bid price): $ 8•GXD Describe the scope of woriin detail: 1 b 4- f. .1- i414 41 .11etil-Puis 0-CoYlo rn S8/ Use: Residential: New Commercial: New Fuel Type: Electric [V]/ Replacement Replacement Gas ❑ Other: H:\Applications\Forms- Applications On Line\201 l Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being ins ailed and the quantity below: Unit Type Qty'; Furnace <100k btu 1 Furnace >100k btu Floor furnace Suspended/wall /floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit 1 >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper 1 Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor' ‘ Qty'. 0 -3 hp /100,000 btu 1 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1:1 I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN !-.• R AU • ' IZED : GENT: ��/ Signature: ��� % %! '� Date: S —'/ c(' 2 Print Name: /4212 1,01%bt/e4 Day Telephone: ga9Pez Mailing Address: L/0/17 6/4/ e- G , lacoma City H:\Applicattons\Forms- Applications On Line\2011 Apphcations\Mcchanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7999600066 Address: 5219 S 144 ST TUKW Suite No: Applicant: KISSINGER BUILDING RECEIPT Permit Number: M12 -072 Status: PENDING Applied Date: 05/04/2012 Issue Date: Receipt No.: R12 -01497 Payment Amount: $281.56 Initials: JEM Payment Date: 05/04/2012 11:03 AM User ID: 1165 Balance: $0.00 Payee: RANGER HEATING AND COOLING TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2065 281.56 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 225.25 000.345.830 56.31 Total: $281.56 doc: Receiot -06 Printed: 05 -04 -2012 4- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 Project: /a</5T,Z- /CAR a2/' 'xi Type of Inspection: , .. . /2 i/y h " /A/ Address: ,5 /may .S / 4/ 4/ cS T Date Called: - Special Instructions: Date Wanted:. /.Z - -/Z m:; . ''p.m: Requester: Phone No: 0,253 -293 7 43'-6" li4err ,V-1 0. Mii 072 rf-view approval is subject to errors and omissions, of construction documents does not authorize ti iton of any adopted code or ordinance. Rep: Luproved Field Copy and conditions is acknowle4ed 38 —7 By Date: — City Of Tukwila BUILDING DIVISION 39' SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Electrical Plumbing CiOtras Piping of Tukwila DIVISION 1 REVISIONS , No changes shall be made to the scope 4 ,i of work without prior approval of , , 77..ikwila Building Division. will require a new plan submittal 7;•::.:_!de additional plan review fecs. i 44,— Area: 37,6 SQ Perimeter: 260 LF Corners: 4 EA Scuppers: 6 EA EB 2' — 6" ROOF PLAN )) umeanner REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 3 2012 vlic City of Tukwila BUILDING DIVISION PROJECT: 219 1441h DATE. 04/12/2-012 RECEIVE CITY OF TU MAY 0 4 2012 PERMIT CENTER AUTHOR: Liana, ROOFCORP a guarantee of quality M E.- 0 E FILE COPY Q�.rryw RA O.% Customer : Project : Name : W4C 1 Model Number WSC060E1 R0 " "`0 3 -10 Ton R-410 Packaged Heat Pump General Unit function Airflow application Elevation Cooling EDB Ent Air relative humidity Heating EAT Heating ambient WB Voltage Evaporator rows Evaporator face area Max unit operating weight ASHRAE 90.1 DX cooling Downflow 0.00ft 80.00F 0.00% 70.00F 42.60F 208 - 230/60/1 4.00Each 9.27sq ft 944.01 b Yes Airflow Design Airflow Tonnage Cooling EWB Ambient Temperature Heating ambient temp Heating ambient relative humidity Design ESP Evaporator fin spacing Evaporator face velocity Min. unit operating weight Rated capacity (AHRI) Convertible 2000cfm 5 Ton 67.00F 95.00F 47.00F 70.00% 0.500in H2O 192Per Foot 216ft /min 682.01 b 57 CDQ Compressor power - heat 0.00kW Main Cooling Compressor power - heat Gross Sensible Capacity Evap Coil Leaving Air Temp (DB) Cooling LDB Dew Point Temp Net total capacity Net sensible heat ratio Refrig charge (HFC -410A) - ckt 2 Saturated Suction Temp 1 Saturated Suction Temp 2 0.00kW 44.32MBh 59.48F 60.58F 56.45F 56.6OM Bh 0.75Number 0.OIb 47.35F 0.00F Saturated Suction Temp Circuit 1 33.79F - HP Saturated Suction Temp Circuit 2 0.00F - HP Gross Total Capacity Gross Latent Capacity Evap Coil Leaving Air Temp (WB) Cooling LWB Fan motor heat Net sensible capacity Refrig charge (HFC -410A) - ckt 1 Saturated Discharge Temp 1 Saturated Discharge Temp 2 Saturated Discharge Temp Circuit 1 - HP Saturated Discharge Temp Circuit 2 - HP 58.36MBh 14.04M Bh 57.63F 58.05F 1.76MBh 42.56MBh 10.OIb 112.18 RE1/IBVVED FOR 0.00F CODE COMPL Y , 105.60 APPROVED MAY 2 3 2012 0.00F CDQ Performance City of Tul4lt BUILDING • �:..® Compressor power - heat 0.00kW Main Heating CITY OF TUKWILA. MAY 042012 PERMIT CENTE RN.12-b41E Compressor power - heat Output htg capacity w /fan Heating delta T 0.00kW 58.50M Bh 27.08F Output htg capacity Heating LAT 56.74MBh 97.08F Motor/ Electrical Compressor power - heat Component S.P. Max available ESP Indoor mtr operating power Outdoor motor power System power MCA MCA for 230v w /elec heat Compressor 1 RLA Condenser fan FLA Exhaust fan power 0.00kW 0.000in H2O 0.620in H2O 0.56bhp 0.36kW 5.05kW 44.60A 0.00A 27.60A 2.50A 0.O0kW Electric heat static pressure add Total Static Pressure Indoor srpm Indoor Motor power Compressor power SEER @ARI MOP MOP for 230v w/ elec heat Compressor 2 RLA Evaporator fan RLA 0.000in H2O 0.5 87Orpm 0.42kW 4.27kW 13.00btuh /watt 70.00A 0.00A 0.00A 7.60A Packaged Heat Pump 3 -5 Ton Unit efficiency Micro - processor controls Standard efficiency Microprocessor controls 1 ph Major design sequence Major design sequence Field Installed Accessories Roof curb Barometric relief Electric heaters Roof curb Barometric relief 18 kW Electric heater 1 ph Fresh air selection Options module Dry bulb econ 0 -100% w/o bar relief Options module Page 2 EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 3/4' -14 NPT DIA. HOLE TOP PANEL CONDENSER FAN 4 1/4' 27 5/8' 47 7/8' 2" ELECTRICAL CONNECTION (SINGLE POINT POWER WHEN HEAT INSTALLED) THROUGH THE BASE CONDENSATE CONDENSER COIL .• RVICE GAUGE PORT ACCESS 1 3//8' DIA.LHOLE -Or/ NIT POWER WIRE PLAN VIEW UNIT DIMENSION DRAWING 00 CONDENSATE 88 5/B' 32 /4' 40 4 3/4" 3 7/8" PACKAGED HEATPUM ONTROLAND COMPRESSOR ACCESS PANEL NOTES: 1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2. VERIFY WEIGHT. CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION RETURN SUPPLY 23 r 718' 0 7- 00 CONDENSATE 88 5/B' 32 /4' 40 4 3/4" 3 7/8" PACKAGED HEATPUM ONTROLAND COMPRESSOR ACCESS PANEL NOTES: 1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2. VERIFY WEIGHT. CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 718' i s. i 0 0 18 1 0 9518' O DIMENSION DRAWING HORIZONTAL AIR FLOW Page 3 ELECTRICAL / GENERAL DATA GENERAL (2)14x6) Model: WSC060E Unit Operating Voltage: 187 -258 Unit Prim ary Voltage: 208 Unit Secondary Voltage: 230 Unit Hertz: 60 Unit Phase: 1 Oversized Motor MF: N/A NIA MFS : MCB: N/A WITH HEATER Heater kW Rating: Stage: MCA: MFS MCB 13.2/17.6 2 124.1/136.2 125.0/150.0 125.0/150.0 SEER 13.0 Standard Motor Field Installed Oversized Motor Oversized Motor Field Installed Overszed Motor Minimum CircuitAmpacity: 44.6 MCA: N/A MCA: N/A MCA: Maximum Fuse Sae: 70.0 MFS: N/A MFS: N/A MFS: Maximum (HACR) Circuit Breaker. 70.0 MCB: N/A MCB: N/A MCB: INDOOR MOTOR Sanderd Motor Outsized Motor Field Installed Oversized Motor Number: 1 Number: N/A Number: N/A Motor Speed (RRM): 1.0 Motor Speed (RRM): N/A Motor Speed (RRM): N/A Horsepower: -- Horsepower: N/A Horsepower: N/A Phase: 1 Phase: N/A Phase: N/A Full Load Amps: 7.6 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: -- Locked RotorAmps: N/A Locked Rotor Am ps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: 1 Number: 1 Horsepower: 4.8 Horsepower 0.40 Phase: 1 Motor Speed (RRM): 1075 Rated Load Amps: 27.8 Phase: 1 Locked Rotor Amps: 158.0 Full Load Am ps: 2.5 Locked Rotor Amps: 6.6 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R410 Phase: N/A Type: Throwaway Horsepower: N/A Numished: Yes Factory Charge Motor Speed (RPM): N/A Number 4 Cirui[ #1 10.0 lb Full Load Amps: N/A Recommended 16'x25'x2' Ciruit #2 N/A Locked Rotor Amps: N/A NOTES: 1. Maxim um (HACR) Circuit Breaker sizing is for installations in the U nited States only. 2. Refrigerant charge is an approxim ate value. For a more precise value. see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value includes oversized m otor. 5. Value does not include Power Exhaust Accessory. 6. EER is rated at AHRI conditions and in accordance with DOE test procedures. Page 4 PACKAGED HEAT PUMP CORNER WEIGHT INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0 lb MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF 10.0 Ib OVERSIZED MOTOR N/A BELT DRIVE MOTOR POWER EXHAUST N/A HEATER 30.0 lb THROUGH T THE BASE ELECTRICAL (FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD SMOKE DETECTOR,SUPPLY /RETURN ROOF CURB 76.0 Ib BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET ® 226.0 Ib © 114.0 lb (E)LENGHT (F) WIDTH 625.01b 682.0 Ib O 177.0 Ib DO 163.01b 38' 24' NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3. BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORYWEIGHT. TO OBTAIN TOTAL WEIGHT,ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4. W EIGHTS FOR OPTIONS NOT LISTED ARE >5 LBS. PACKAGED HEAT PUMP RIGGING AND CENTER OF GRAVITY Page 5 CLEARANCE 38' CLEARANCE 48' CLEARANCE FROM TOP OF UNIT 72' DOWNFLOW CLEARANCE 38' HORIZONTAL CLEARANCE 18' ROOF OPENING UNIT OUTLINE CLEARANCE 36' PACKAGED HEAT PUMP CLEARANCE 46 88 518 PACKAGED HEAT PUMP 46' 53 114' DOWN FLOW TYPICAL ROOF OPENING Page 6 33 314' 3M' 314' 33 314' Downtlow Duct Connections - Field Fabricated All Flanges - 1 114' ACCESSORY - DUCT CONNECTIONS Page 7 49 ACCESSORY - ROOFTOP CURB ACCESSORY - ROOFTOP CURB Page 8 84' 18 1/2' 1' 518' -o-- 18 1/2' 1' 1 34 7/8' 3/8' 34 3/8' ACCESSORY - ROOFTOP CURB Page 8 BAROMETRIC RELIEF HOOD BAROMETRIC RELIEF HOOD 7 314 11' ACCESSORY - BAROMETRIC RELIEF DAMPER HOOD CONOMIZER HOOD Page 9 CONOMIZER HOOD CONOMIZER HOOD ACCESSORY - ECONOMIZER H000 Pagel() General The units shall be convertible airflow. The operating range shall be between 115 °F and 0 °F in cooling as standard from the factory for units with microprocessor controls. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R -410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, and galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather - resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil- faced, fire - retardant permanent, odorless glass fiber material. All insulation edges shall be either captured or sealed. The units base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8" high downflow supply /return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double- hemmed and gasket - sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters 1 ", throwaway filters shall be standard on 3 -5 ton gas electric / cooling only standard efficiency units.2 ", throwaway filters shall be standard on all 6 -10 Ton standard efficiency units and all high efficiency gas electric / cooling units. 2 ", throwaway filters shall also be standard on all 3 -10 ton heat pumps. Compressors All units shall have direct - drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas - cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Crankcase heaters shall be included in 6 -10 Ton. Refrigerant Circuits Service pressure ports, and refrigerant line filter driers are factory - installed as standard. An area shall be provided for replacement suction line driers. Evaporator and Condenser Coils Internally finned, 5/162 copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 650 psig and pressure tested to 450 psig. The condenser coil shall have a patent pending 1 +1 +1 hybrid coil designed with slight gaps for ease of cleaning. A removable, reversible, double - sloped condensate drain pan with through the base condensate drain is standard. Outdoor Fans The outdoor fan shall be direct - drive, statically and dynamically balanced, draw- through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built -in thermal overload protection. Indoor Fan All 3 -5 ton 1 -phase and 10 ton 3 phase units offer shall be direct drive type. All all other 3 phase ID motors shall be belt drive type with FC fans with adjustable sheaves. All motors shall be thermally protected. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Controls Unit shall be completely factory -wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for volt control functions. The resident control algorithms shall make all heating, cooling, and /or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm Page 11 maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized Microprocessor shall provide anti -short cycle timing and time delay between compressors to provide a higher level of machine protection. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Accessory - Electric Heaters Electric heat modules shall be available for installation within basic unit. Electric heater elements shall be constructed of heavy -duty nickel chromium elements internally delta connected for 240 volt, wye connected for 480 and 600 volt. Staging shall be achieved through ReliaTel. Each heater package shall have automatically reset high limit control operating through heating element contactors. All heaters shall be individually fused from the factory, where required, and shall meet all NEC and CEC requirements when properly installed. Power assemblies shall provide single point connection. Electric heat modules shall be UL listed or CSA certified. Accessory - Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0 -100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. Accessory - Roof Curb The roof curb shall be designed to mate with the unit's downflow supply and return and provide support and a water tight installation when installed properly. The roof curb design shall allow field fabricated rectangular supply /return ductwork to be connected directly to the curb. Curb design shall comply with NRCA requirements. Curb shall be shipped knocked down for field assembly and shall include wood nailer strips. Page 12 SWOET A STRUCTURAL ENS ENGINEERING N SAY FAG CORPORATION STRUCTURAL REMODEL KISSiNGER BUILDING (mechanical unit) 5215 S. 144th Seattle WA. For: Lance Kissinger 12216 11th Ave. NW Seattle WA. 98177 206 -228 -4033 www.swensonsayfaget.com FILE COPY Permit No to errors and ornisPI ~ns. RECEIVED .. CITY OF TUKWILA MAY 0 4 2012 PERMIT CENTER REVIEWED FOR ODE COMPLIANCE APPROVED MAY 2 3 2012 City of Tukwila BUILDING DIVISION IirO12 SEA 2124 Third Ave, Suite 100, Seattle, WA 98121 TAC 934 Broadway, Suite 100, Tacoma, WA 98402 P 206.443.6212 F 206.443.4870 P 253.284.9470 F 253.284.9471 Kissinger Bldg E-4 cf=2 goo oimk, rce iMa.ii'04.-tv iv! �'�e vv► vtiw►A [ v 5 _;2 13,.15 six 2 S �s c L4 sad tO' o. trJ yko: 40'4 evf ere, �a3 f4.1`' 4° 'LT 3�6 t.15° aq c,t 1J lip ( p L4 L.% 5,1,51 Ct?,747")," vet a Stex: km 'i, f ---- -- 6� •l 55 ts 1 t week TL otttS tle" rt L z5 2d4 1p V. tzt. 2. 21,1 24( Mcf (V C, 4.1. eel (cc 10 /1 �9sr, 4 hem: c t v./sic 134°` i/2 96 r,77 5z /98 l2- 4120 B 14.k `d G , /2* eq z. Z1,1 r SWO FAGET A STRUCTURAL ENS ENGINEERING N SAY CORPORATION Sea t tle: 2124 Third Avenue • Suite 100 • Seattle • WA 98121 Tel: 206.443.6212 Fax: 206.443.4870 Tacoma: 934 Broadway • Suite 100 • Tacoma • WA 98042 Tel: 253.284.9470 Fax: 253.284.9471 Project Asr:;7. Date Pro). No. ilesC Design Sheet A Roof Support Documentation.xls Kissinger Building Dimensions of°roof support system and components 5219 S 144th St; Tukwila, WA 98168 Legend for su000rt positions Position Description Feet • Position Description .::: Position Description Position Position Description E-0 . North: Pilaster . Inches EM -0 North Pilaster. 3:875.:0.322916667 WM =0 North Pilaster W -0 North Pilaster E -1 1st Support : Pilaster 9.25 EM -1 1st :Support Pole .. WM -1 1st Support Pole E-0 W -1 1st Support Pilaster E -2 2nd. Support . Pilaster 0 , EM -2 2nd Support Pole .. WM -0 WM -2 2nd Support Pilaster W -2 2nd Support Pilaster E -3 3rd Support Pilaster 217.5 EM -3 3rd Support Pole EM -1 WM -3 3rd Support Pole W -3 3rd Support Pilaster E-4 Wall Pilaster W -1 EM-4 Wall Pilaster E -2 WM-4 Wall Pilaster :: W-4 Wall Pilaster E -5 South Pilaster WM -2 EM -5 South Pilaster WM -5 South Pilaster 17.95833 W -5 South Pilaster North - South Measurements for center of supports &beam section lengths Position Inches.. Feet Position Inches Feet Position Inches Feet Position . Inches Feet Beams Width 3:875.:0.322916667 9.25 0.770833 9.25 0.770833 3.875 0.322917 E-0 0 0 EM-0 0 0 WM -0 0 0 W -0 0 0 E -1 217.5 18.125 EM -1 217.5 .18.125 . WM -1 217.5 18.125 W -1 217.5 18.125 E -2 215.5 17.95833333 :: EM -2 215.5 17.95833 WM -2 215.5 17.95833 W -2 215.5 17.95833 E -3 183 15.25 EM -3 183 15.25 WM -3 183 15.25 W -3 183 15.25 E-4 182.5 15.20833333 EM-4 182.5 15:20833 WM-4 182.5 15.20833 W-4 182.5 15.20833 E -5 236 19.66666667 EM -5 236 19.66667 WM -5 236 19.66667 W -5 236 19.66667 Total interior length 1034.5 86.20833333 Beam Spacing. Measurements East to West (Center to Center) Position :Inches Feet Position Inches Feet Position Inches Feet Position Inches Feet Interior W East East Mid 165 13.75 West Mid 165 13.75 West 165 13.75 41.25 Beam Dimensions Beam Height 13.75. 1.145833333 13.75 1.145833 13.75 1.145833 13.75 1.145833 Beams Width 3:875.:0.322916667 9.25 0.770833 9.25 0.770833 3.875 0.322917 Beam Bottom to Floor 155 12.91666667 155 12.91667 155 12.91667 155 12.91667 Beam Top to Floor 169 14.08333333 169 14.08333 169 14.08333 169 14.08333 Joists materials are 2" X 10" on 16" centers. Joists run from wall beams across to the inside of the central beams. Central oists run to outside of each central beam they span. Roof. Sub Deck is 3/4" X 7" Tongue and Groove oriented North and South Support Poles Steel 3.5" OD with 3/8" Wall are embedded in the cement slab Plates welded on top of poles-23" long X 12" wide X 3/8" thick. 3" Flange on long sides Front, Side and South Pilasters 15 3/4" X 4" Heat :pump to be installed on Roof Trane, 5 ton heat pump with 20kw strip heat ,with Economizer. Weight 682 pounds + metal curb roughly 70 pounds. Roof:Curb weights 70 pounds, Dimensions W 50" X L 84" X H 14 ". Roof: mounting flange is 1 3/4" wide Building. Shell 8" X 16 "X 8" Masonary Blocks on a cement slab. floor. 3 =aw C: \Documents and Settings \gmackenzie \Local Settings \Temporary Internet Files \Content.Outlook\5DU2USZO\Roof Support Documentation.xls Page 1 PACKAGED HEAT PUMP CORNER .WEIGH T INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.01b MOTORIZED 011 TSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF 10.010 OVERSIZED MOTOR N/A BELT DRIVE MOTOR POWER EXHAUST N/A HEATER 30.0 1b THROUGH THE BASE ELECTRICAL (FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET ( FIOPS) HINGED DOORS (FIOPS) HAIL GUARD SMOKE DETECTOR, SUPPLY /RETURN ROOF.CURB. ,_ . 78.010 BASICUNITWEIGHTS CORNER WEIGH TS . . CENTER OF GRAVITIY SHIPPING NET O 228.01b 114.01b (E)LENGHT (F)WIDTH 625.0 lb 682.01b 0 177.01b DO 183.010 36 '. 24' NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. • 3. BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT. TO OBTAIN TOTAL WEIGHT :ADD. ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. • 4. WEIGHTS FOR OPTIONS NOT LISTED ARE >5 LBS. PACKAGED HEAT PUMP RIGGING AND CENTER OF GRAVITY Model Number WSC060E1 R0 * * * *0 Customer : Project : Name : W4C 1 3 -10 Ton R-410 Packaged Heat Pump General Unit function Airflow application Elevation Cooling EDB Ent Air relative humidity Heating EAT Heating ambient WB Voltage Evaporator rows Evaporator face area Max unit operating weight ASHRAE 90.1 DX cooling Downflow 0.00ft 80.00F 0.00% 70.00F 42.60F 208 - 230/60/1 4.00Each 9.27sq ft 944.OIb Yes Airflow Design Airflow Tonnage Cooling EWB Ambient Temperature Heating ambient temp Heating ambient relative humidity Design ESP Evaporator fin spacing Evaporator face velocity Min. unit operating weight Rated. capacity (AHRI) Convertible 2000cfm 5 Ton 67.00F 95.00F 47.00F 70.00% 0.5001n H2O 192Per Foot 216ft/min y. 682.OIb + Roo s" 8co 57 Main Cooling Compressor power = :heat Gross 'Sensible Capacity Evap Coil Leaving Air Temp (DB) Cooling LDB • Dew Point Temp Net total capacity Net Sensible 'heat ratio Refrig :charge (HFC -410A) - ckt 2 Saturated Suction Temp 1 ,Saturated Suction Temp 2 0.00kW 44.32MBh 59.48F 60.58F 56.45F 56.60MBh 075Number 0.0Ib 47.35F 0.00F Saturated Suction Temp Circuit. 1 . 33.79F. -.HP. Saturated Suction Temp Circuit 2 0.00F - HP Gross Total Capacity Gross Latent Capacity Evap Coil Leaving Air Temp (WB) Cooling LWB Fan motor heat Net sensible capacity Refrig charge (HFC -410A) - ckt 1 Saturated Discharge Temp 1 Saturated Discharge Temp 2 Saturated Discharge Temp Circuit 1 -HP 58.36MBh 14.04MBh 57.63F 58.05F.. 1.76MBh 42.56MBh 10.OIb 112.18F O.00F. 105.60F Saturated. Discharge. Temp Circuit 0.00F 2 - HP CDQ Performance Main Heating TOP PANEL EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 314' -14 NPT DIA. HOLE CONDENSER FAN 4 114' 27 518' 47718' 2' ELECTRICAL CONNECTION (SINGLE POINT POWER WHEN HEAT INSTALLED) THROUGH THE BASE CONDENSATE 27 518' r SUPPLY 4 I/O" 33' RETURN 1 17 112' PLAN VIEW_ UNIT 9 718' DIMENSION DRAWING 17 112' 4 SUPPLY 23 718' CONDENSER COIL NIT CONTROL WIRE 718' DIA. HOLE y • ERVICE GAUGE PORT ACCESS 1 318' DIA. HOLE ✓� NIT POWER WIRE 32 118' i 3 518' 111-3 RETURN. 00 l 00 CONDENSATE 9 318' x-18 314' --d 88 518 32 14' 4 3 4' 3 718' ONTROLAND COMPRESSOR ACCESS PANEL NOTES: 1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2. VERIFY WEIGHT, CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 40718' PACKAGED HEATPUMP 18 11T 9518'55!8' 4 114' 5 518' 7 518' DIMENSION DRAWING 53 114' HORIZONTAL AIR FLOW CLEARANCE 38' CLEARANCE 48' CLEARANCE FROM TOP OF UNIT 72' DOWNFLOW CLEARANCE 38' HORIZONTAL CLEARANCE 18' ROOF OPENING UNIT OUTLINE CLEARANCE 38' PACKAGED HEAT PUMP CLEARANCE 46' 46' 88 518' PACKAGED HEAT PUMP 53 114' DOWN FLOW TYPICAL ROOF OPENING 33 314" 3/4' 33 3/4' r�� Downflow Duct Connections - Field Fabricated 141111., AB Flanges- 11/4' ACCESSORY - DUCT CONNECTIONS BAROMETRIC RELIEF HOOD BAROMETRIC RELIEF HOOD 7 314• 12' ACCESSORY - BAROMETRIC RELIEF DAMPER HOOD CONOMIZER HOOD • •'� City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 1, 2012 Lance Kissinger R & T Kissinger Trust 12216 11`h Ave NW Seattle, WA 98177 RE: Request for Extension Mechanical Permit Number M12 -072 Kissinger Building — 5219 S 144 St Dear Mr. Kissinger, This letter is in response to your written request for an extension to Permit Number M12 -072. The Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending your permit an additional 180 days from the date of expiration, April 29, 2013. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, File: Permit No. M12-072 W: \Permit Center \Extension Letters \Permits\2012\M12 -072 Permit Extension.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Lance Kissinger • 12216 11th Avenue NW Seattle, WA 98177 206 228 -4033 09 -28 -12 Bill Rambo, Permit Technician City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 RE: Permit Application No. M12 -072, Kissinger Bldg, 5219 S 144th ST, Tuk Dear Mr.Rambo, This letter is a request for extension of the permit M12 -072 in response to your letter dated 09- 04 -12. Due to the circumstances of the time to move electrical service and install new breaker panels we may not get the electrical service hooked back up by City Light in time for my vendor to finish off this permit inspection before the permit runs out. Currently the Heat Pump unit is mounted on the roof and plumbed by my electrician and his permits are finalized for the new electrical panel installations. We a just waiting for City light to hook up the external service and turn the service back on at the pole before we can finalize the mechanicals inspection. Thank you, L. ce Kissinger, Trustee R & T Kissinger Trust. omi Jo efrgAid 00 dal cf/teibort RECEIVED *TV OF TUKWItA 28 2o12i PERMIT CENTER tKy 0 -3_c)■ C'f� 0`i'21 . (3 09 -04 -2012 • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director LANCE KISSINGER 12216 11 AV NW SEATTLE WA 98177 RE: Permit Application No. M12 -072 KISSINGER BUILDING 5219 S 144 ST TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 05/04/2012, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 10/31/2012. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M12 -072 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431 -3670 • Fax 206 -431 -3665 'PERMIT COORD CORD PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -072 DATE: 05/04/12 -PROJECT NAME: KISSINGER BUILDING SITE ADDRESS: 5219 S 144 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Alin cirb.vi, ling 'vision Fire Preven Ion Public Works Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 05/08/12 Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Eg Structural Review Required n I�I No further Review Required I I REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/05/12 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 02/29/12 Contractors or Tradespeople Prr Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name RANGER HEATING & COOLING LLC UBI No. 603021557 Phone 2069131123 Status Active Address 4014 61St Ave E License No. RANGEHC9050M Suite /Apt. License Type Construction Contractor City Fife Effective Date 9/14/2010 State WA Expiration Date 9/18/2014 Zip 98424 Suspend Date County Pierce Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status RANGEH'928RN RANGER HEATING Construction Contractor Heating /Vent /Air- Conditioning And Refrig (Hvac /R) Unused 12/15/2008 12/15/2010 Re Licensed Business Owner Information Name Role Effective Date Expiration Date KALLANDER, DAVID THOMAS Partner /Member 09/14/2010 Bond Amount QUY, SEAN RYAN Partner /Member 09/24/2010 am9069166 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 UPPER HUDSON am9069166 08/05/2012 08/25/2013 $1,000,000.00 09/11/2012 2 NATIONAL INS 50192400 08/15/2011 Until Cancelled $12,000.0008/22 /2011 COMPANY 1 American ins Co 0763303 0763303 09/07/2010 08/22/2011 10/15/2011 $6,000.00 09/14/2010 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 Country Mutual Ins Co am9069166 08/05/2012 08/25/2013 $1,000,000.00 09/11/2012 1 Country Mutual Ins Co 9069166 08/25/2010 08/25/2012 $1,000,000.00 07/25/2011 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https: / /fortress.wa. gov /lni/bbip /Print.aspx 12/05/2012