Loading...
HomeMy WebLinkAboutPermit M12-073 - WESTFIELD SOUTHCENTER MALL - ALDOALDO SHOES 657 SOUTHCENTER MALL M12 -073 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 657 SOUTHCENTER MALL TUKW Project Name: ALDO SHOES Permit Number: M12 -073 Issue Date: 06/18/2012 Permit Expires On: 12/15/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: TIM SCHENK Address: 1120 E 80 ST STE 211 , BLOOMINGTON MN 55420 Email: TIMS @ELDERJONES.COM Phone: 952 345 -6040 Contractor: Name: SAJO INC Phone: 514 - 850 -0333 Address: 1320 GRAHAM BL , MONT -ROYAL QUEBEC CANADA H3PC8 Contractor License No: SAJOII*893CZ Expiration Date: 03/04/2013 DESCRIPTION OF WORK: REMODEL OF AN EXISITING RETAIL TENANT SPACE. EXISTING VAV BOX, NEW DUCTWORK, DIFFUSERS, RETURN AIR GRILLE, RELOCATE EXISTING CONTROLS, NEW BATHROOM EXHAUST FAN, AND DUCT WORK. Value of Mechanical: $20,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $428.56 International Mechanical Code Edition: 2009 `,r Date _ . ' W I hereby certify that I have read and examined this pe i t and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: o+rle S f'Y)p� "hews Date: e0//s/12 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -073 Printed: 06 -18 -2012 • • PERMIT CONDITIONS Permit No. M12-073 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: ** *PLUMBING AND GAS PIPING * ** doc: IMC -4/10 M12 -073 Printed: 06 -18 -2012 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. ,l t O; ' 0`3 Project No. f -- Vi t_ Date Application Accepted: C 12, Date Application Expires: 1 l 014 1 Z (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION W J] King Co Assessor's Tax No.: 4320 297 0010 Site Address: 0 SGifl r a MAk.._ Suite Number: /S2S Floor: 1 Tenant Name: ALPO PROPERTY OWNER Name: WE. t EL0 (-LC Address: 633 soaor •Olsatt. 0.113,(ka City: S e.ivat li State: k% Zip :cicaty CONTACT PERSON — person receiving all project communication Name: Ti SCAECNj._ Address: I M.0 E ' 80 tl•s (ZkErt Svi re zi) City: 6uz tt`i6 tlt■1 State: pa 4,,r Zip;s5fV Phone:q ...545..6340 Fax:gv.ssi .y909. Email: -1-- • in @. caof Qf ,l oneis ..,.. New Tenant: ❑ Yes pi ..No AUX) ClAtUrval i a IN TUC /'ui'.A - MECHANICAL CONTRACTOR INFORMATION Company Name:,('$.° . SCe3 0 Cons-Irm GUI 0)1 Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 204000. Describe the scope of work in detail: a e l r n o r . ale= O C 1 s KG ' Z E r 4, I ( . t u 4,4 r SFhc. - / ricr S&✓rI Uelvf..r1/4.. Mau.. Exi sneit, VAV t kut . Kay' O crwanuc. , pt,gx-vs0. s t (t iTakt .r pa Gn i c.�. . gEta o l ter €50SJI (!4 C Kral S /Icy( t Artute%nr. Ex wars*- P-414 0NIG Use Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement * E X ∎ S C►rJ 6- VnV 140-4 OVCd 1 itl(11 =d' 0111AlS .S Fuel Type: Electric Gas ❑ Other: (HAUL SVPP(tW A& H:\ Applications \Forms - Applications On Line \2011 Applications\Mechanical Permit Application Revised 8 -9 -I I.docx Revised: August 2011 bh Page 1 of 2 1 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 1141 Floor furnace Suspended /walUfloor mounted heater , Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit 4 <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm 1141 Evaporator cooler Ventilation fan connected to single duct , Ventilation system Hood and duct Incinerator — domestic 4 Incinerator — comm/industrial Unit Type Qty Fire damper 1 Diffuser 1141 Thermostat gealaP944. Wood /gas stove Emergency generator Other mechanical equipment (MUM1N A rt► 4 MAUI A Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES'- Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR<; ✓V ORIZED AGENT: Signature: Date: Print Name: 'T"I, M Sci4o -41.e. Day Telephone: .34r- 60 Mailing Address: I i2A E •gnasttt,2�r 1 squw % . C omir(6 , mg 04Z.Q City State H: \Applications \Forms- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8 -9 -1 I.docx Revised: August 2011 bh Zip Page 2 of 2 • a 1-6A., 4v titt,3 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M12 -073 Address: 657 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 05/04/2012 Applicant: ALDO SHOES Issue Date: 06/18/2012 Receipt No.: R12 -02303 Payment Amount: $63.00 Initials: WER Payment Date: 08/07/2012 03:38 PM User ID: 1655 Balance: $0.00 Payee: CHARLES MATTHEWS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 143379 ACCOUNT ITEM LIST: Description 63.00 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 63.00 Total: $63.00 doc: Receipt -06 Printed: 08 -07 -2012 City of Tukwila Department of Community Development 6300 Southcenter Boulevard,'Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT ParcelNo.: 9202470010 Permit Number: M12 -073 Address: 657 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/04/2012 Applicant: ALDO SHOES Issue Date: Receipt No.: R12 -01897 Payment Amount: $342.85 Initials: TLS Payment Date: 06/18/2012 11:34 AM User ID: 1670 Balance: $0.00 Payee: SAJO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 01024142 342.85 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 342.85 Total: $342.85 doc: Receiot -06 Printed: 06 -18 -2012 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT ParcelNo.: 9202470010 Permit Number: M12 -073 Address: 690 SOUTHCENTER MALL TUICW Status: PENDING Suite No: Applied Date: 05/04/2012 Applicant: ALDO SHOES Issue Date: Receipt No.: R12 -01503 Payment Amount: $85.71 Initials: TLS Payment Date: 05/04/2012 01:26 PM User ID: 1670 Balance: $342.85 Payee: ELDER -JONES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 62141 85.71 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 85.71 Total: $85.71 doc: Receipt-06 Printed: 05 -04 -2012 k�3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 R (206) 431-3670 Permit Inspection Request Line (206) 431 -2451 M Z73 Project: ,,11 sk. Type 9£.Inspectio : A A ' Address: 7 se_ AtAti Date Called: /ti Special Instructions: -_.}, ,( 4-&C-C. ftq Jr ( "' 1 Date Wanted:. _ &-� Z... -- m. Requester: Phon N /-? 44 f Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: n-ertitTTw n(e)? Inspectq,r: i1 Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD.' Retain a copy with permit INSPE TION NO. _PERMIT NO. CITY OF TUKWILA BUILDING. DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 -:,' (206) 431- 3670 Permit Inspection Request Line (206) 431 -2451 ryl 1 ? -o7 Project: A t-iDO SHOES Type of Inspection :` -2-(C!--1 _Tic15�i Address: ( -7 ,M A L./— Date Called: Special Instructions: Date Wanted. alri„ Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. COMMENTS: PECTION FEE R 4UIRED. P t 6300 Southcenter lvd.. Sui ior to next inspectionfee. must be,. e 100. Call to schedule. reinspection: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 M12 -O7 --"S Project: A Lflc) z. (-‘oec..., Type of Inspection: Rchi6t--1 --L-ENi Address: (e)57 Go Nr\--- rix A LC_ Date Called: Special Instructions: Date Wanted: 6-,— 2-7— f 7.- p.m. Requester: Phone No: ev.We— Sci 6- s'sq Z,, pproved per applicable codes. El Corrections required prior to approval. Ji COMMENTS: • Da7:_77 • INSPECTION FEE QUIRED. P ior to next inspection, fee must be ' aid at 6300 Southcen er Blvd.. Suite 100. Call to schedule reinspection. Project Name: Location: Architect Engineer: Contractor. EAGLE TEST & BALANCE COMPANY AABC CERTIFIED 815 E. Main Cushing, OK 74023 Phone: 918 - 225 -1668 Fax: 918 - 225 -1687 13047 S.E. 47th Place Bellevue, WA 98006 Phone: 425 - 747 -9256 Fax: 425 -641 -5662 TEST AND BALANCE REPORT Aldo Seattle, WA Washington Heating & Air Conditioning Project Number. ETB -12 -1678 x.013 This is to certify that Eagle Test & Balance has balanced the systems described herein to their optimum performance capabilities. The testing and balancing has been performed in accordance with the standard requirements and procedures of the Associated Air Balance Council and the results of these tests are herein recorded. Associated Air Balance Council Certification Number. 93 -02-01 Dates. 9/2/12. Form #89010 1 EAGLE TEST & BALANCE COMPANY • Project Name Aldo Project #: ETB -12 -1678 Date: 812112 System: (VAV) FP -1 AIR DISTRIBUTION TEST SHEET Term # Room # Term Term Factor Design FPM Design CFM Test FPM or CFM Final Final Type Size Test 1 Test2 Test 3 FPM CFM VAV 1 AB 8" 1.0 200 195 200 200 2 AB 8" 1.0 200 180 190 190 3 AB 8" 1.0 200 225 200 200 4 AB 8" 1.0 200 230 205 205 5 AA 10" 1.0 275 755 250 250 6 AA 10" 1.0 275 255 260 260 7 AA 10" 1.0 275 290 270 270 8 AA 10" 1.0 275 240 265 265 9 AA 10" 1.0 275 235 255 255 Remarks: Form #1.5.10 2 EAGLE TEST & BALANCE COMPANY Project Name: Aldo System: Building System Supply Air Manufacturer- Titus Project #: ETB -12 -1678 Date: 812/12 Constant X Variable TERMINAL UNIT DATA Single X Dual Box # Location Model Size Cal Factor Design CFM Actual CFM Max Cooling Min Cooling Max Heat Max Cooling Min Cooling Max Heat (VAV) FP -1 CEILING ATQS -7 16" .2 2175 1800 2095 1785 Remarks: Form #89041 3 Project Name: Aldo System: EF -1 EAGLE TEST & BALANCE COMPANY w Project #: ETB -12 -1678 Date 8/2/12 FAN DATA FAN EF-1 Actual Equipment Location CEILING Total CFM-Fan Area Served RESTROOM Equipment Manufacturer BROAN 100 Model QTR110L I In I Out Serial Number * * Motor Sheave & Shaft Specified Actual Specified Actual Total CFM-Fan 110 95 Sheave Adjustment Total CFM-Air Dist 100 95 I In I Out I In I Out Tot/Ex Static Pressure .25 * Inlet Pressure * -.04 Discharge Pressure * .8 Fan RPM * DD Motor Sheave & Shaft Specified Actual Specified Actual Motor Mfg BROAN BROAN Sheave Adjustment Motor HP /BHP * * I In I Out I In I Out Phase/Hi 1 1 Voltage 115 121 Amperage 1.0 .8 Motor RPM * DD Motor Sery Fac/Frame # * * Starter Location /Size * * O.L. Heater Size/Rating * Motor Sheave & Shaft DIRECT DRIVE Fan Sheave & Shaft DIRECT DRIVE Belt Size/Number DIRECT DRIVE Sheave Adjustment * CtoC/Motor Mount Adj I In I Out I In I Out Remarks: Form #1.5.7 4 —25Nnu LAMAOW 04710000 AT 014 ARro00111(0 V C�17007110 LAWLOR!, GIGTWGIIC AT 10.1. APP roMAAAhL .. .. ...... .. 1 - 01000 \-0090 CT DETAIL NOT TO SCALE • OMECHANICAL PLAN 1 SC ALE. 1)4• • 1'-0• MECHANICAL EQUIPMENT SCHEDULE . EXISTING FAN POWERED BOX NMK wlvACIL1921 ATMs TA11 1KKan�w im+eu ro�1°! Af°'1d051 I R W"tl IN TINE Anal 7000 ' 00 910 W,M IOWA I121iVAT OW 1 L 160110 LL 1011S1 02 0141 WM 104407110. 11 920 94514 - L.. 96 011A7O AIR DEVICE SCHEDULE IEIt PAM RAN µARK MOM • AA710 0100 NCCK OIS TYR 1b1t0 IN 4 Axaa Sew ORPLNI u. CAI arnuM ■•il • -#PI 11 920 94514 - L.. 96 011A7O EXHAUST FAN SCHEDULE MAN IIAMC MMI?AGTACR 0007110. GPM O!. N VOLT TOT 9N MP. olSa TWO .• 114 1110 • 0100 00001119007 MM 01010000101071. K 11040004 MATOM 0090X MOOD 410201 +101014211111000®1 NOTES BY SYMBOL 0 Fawn IAI0AOcomae cams 114V M. wow co =L aA15 0008 T00TAAN10L Q 11110Y1C1091 WON TACO MEMOMCT I01OV owe' a= to MOO /ME M) 6090116.9151 /OM 1(3 C019101011 BALL 160 ASST 011714 WHOM aarame 00604 1200114103 LO1W Olt 5002 WHO MAW TO L12 1111190120111 T0000 PROM MOL000Me GRATER PMNL1&01011.1!0010 MU 091 q 0.02/19l 02971!1. VAV NOTES 1.01101LY L.NOLGO MCIMOAT W L VAV 1010,24 f 090 EM.07T. NAM TO 110110A09001100. 11015 001(0071 Pm 00000140. INOUTON OM 1.00110.N100 00 FINAL IOW 710107110010 00 L71010000 071014 1 ONTO'. OM ' 100 0.07110X 4(500144 W 0R VAV BOX 100+701 FOLK 0014000071010090700 OF MAWR 00017 •0491710109116141 Or 00 NAV001 NOM. 006(0C10.41011 0904! f�s0*0. VAV AIR A OC910/01OLL4 TO MECHANICAL NOTES 71091/5011 MCP 5011001 N 000001K 0047047T SWL CO 111000 NOMNlrInt WA' AcaswL MR AU 000109 OON A901600&La 1 OM GOT DOLL 00//071000 MTh Wi OKAC P00O{.LAl, ROMP MOONS= OR DIALP00CR OWN PION NK INIER1107107114!5 AT NOIITN.MAV01 Mg1- Ihi'M!!R`07. 0. MC. ROLLVAOT7 CULT LOWS% 011104 MAIM f1R1WM0AIW OZTALIK 1201 COMAISG0! 1(00r2121 10.9WA1L 0009 roLE 0.10f12219, O0M0. WAS IOU MUM 0701371010 ROW 107104 MAW. 17071 OWL PAIR NL 0/N000 NO 001570 WO AG9OOIR010mq RClO N 0200101. 0440192 711NAOCOLN0AN 0.$00 AT 011901 OM KL1N 6 LAIN. 1. WON 900110. TO IOWA NO 8101110 NOR PDX= 1.140 CO MO LYMOM TO Al NRCMIe VAILIL7'A YO KTELOCR' A06CT OCOC 0701100471 TOG OYLL 06 LOOM M1O11D AO 010010 COMM SEMI* 10119101090C 101/000. TOO. RW. 170A0O 11171 Nl00 10000 5041(0K.14HAWN 00O11NM( OWL 6 NO A=R IOW 0071110® 0001105 OR 1160 OM. =am: m110101 PI NOCD.OFlCMN KUM.. 0 ML NNR'ROPVM mow OWSRI01MD 10111, TWO PA0 ATOIW Pa TO rake O mot • LNl W K W T1 II AMMO VT 1.007100=AIN 01751IG112T0 It 400 DEM 0 TOG 1011. MOM NO 10141 MY 00710 0010 2901011'01001I0T O 01000. K M6MAL00 9C111951101111:1101.9 40111 AL1 O 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary MECH -SUM 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised July 2011 Project .�,a#. hiin. Info FILECOPY Project Address ALDO Date 4/30/2012 690 Southcenter Mall #1525 For Building Dept. Use Seattle, WA Applicant Name: Don Penn Consulting Engineer Applicant Address: Grapevine, TX Applicant Phone: 817.410 -2858 Project Description Briefly describe mechanical system type and features. Includes Plans Existing fan powered box with integral 3 KW electric heat strip to remain. Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option ® Simple System 0 Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 E 1 Capacity2 Btu /h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N 90 D J. 1,4, - WAs.4b il ''s:t O'd ' is RV , °`, Heating Equipment Sc -• 9.b. ' ,;•••• '" Equip. ID Equip Type Brand Name' s �t Model No.1 Capacity2 Btu /h OSA cfm or Econo? Input Btuh Output Btuh Efficiency° Heat Recovery Y/N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 CFM SP' HP /BHP Flow Controls Location of Service FP -1 Titus ATQS -7 2350 VAV Stock 1' RPVIE V'en FOR . CTTY OIF CODE COMPLIANCE MAY U 4 2012 APPROVED PERMIT CENTER 1 I MI A ARIA i•If avaifabFle. Rs testea accord' ag to Table 14 -1A through 14 -1G. 3 If required. 4 COP HSPF, Combustion Efficiency, or AFUE, as applicable. 5' Flow control types: variable air vo me(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section 1433. City of Tukwila BUILDING DIVISION M 12 -17/3 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary (back) MECH -SUM 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised July 2011 System Description See Section 1421 for full description of Simple System qualifications. All Systems: ❑ No humidification? ❑ No Reheat? If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ <= 84,000 Btuh? ❑ Economizer ❑ Air cooled? ❑ Packaged sys? ❑ <= 135,000 Btuh? ❑ Cooling Cap < =15 Btuh /ft2? ❑ Heating Cap. > 0 & < =10 Btuh /ft2? If Heating Only: II <1000 cfm? ❑ <30% outside air? ❑ Heating Cap. < =10 Btuh /ft2? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. CSTART ) ap < =15 Heat/Cool Eq. with Cap < =10 ft2, or /ft ? Yes Yes Heating Only Heating /Cooling or Cooling Only Reference Section 1421 Yes Yes Yes Econo Included? Yes Simple System Allowed (section 1420) alifies Economizer Exception tion 1 Yes • Use Complex ► Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist MECH -CHK 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised July 2011 Project Address ALDO IDate 4/30/2012 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the 2009 Seattle Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment Performance N.A. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency N.A. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss N.A. 1411.1 Air - cooled chiller Provide total air and water chiller capacity N.A. 1411.2.1 Water - cooled chiller Full -load and NPLV values adjusted for any non - standard conditions N.A. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule N.A. 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls N.A. 1412.1 Temperature zones Indicate locations on plans ' N.A. 1412.2 Deadband control Indicate 5 degree deadband minimum N.A. 1412.3 Humidity control Indicate humidistat N.A. 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback Yes 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage N.A. 1412.4.2 Optimum Start Indicate optimum start controls N.A. 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule N.A. 1412.6 Combustion heating Indicate modulating or staged control N.A. 1412.7 Balancing Indicate balancing features on plans N.A. 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas and labs N.A. 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. Yes 1412.10 Sgl Zone VAV Ctrls Indicate VAV controls for single -zone systems N.A. 1416.3.2 System Balancing Indicate air and water system balancing requirements Yee 1422 Thermostat interlock Indicate thermostat interlock on plans N.A. 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers N.A. 1412.1 Single zone systems Indicate multiple cooling stage control capability. N.A. 1413.1 Air Econo Operation Indicate 100% capability on schedule N.A. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb N.A. 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. N.A. 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer N.A. 1413.5 Htg. Sys. Impact Indicate that system does not increase heating energy use during economizer operation 1414 Ducting Systems Yes 1414.1 Duct sealing Indicate duct design pressures and sealing requirements Yes 1414.1.2 Low press. duct test Indicate that low- pressure duct systems to be leak tested N.A. 1414.1.3 HP & ext. duct test Indicate that high - pressure & exterior duct systems to be leak tested Yes 1414.2 Duct insulation Indicate R -value of insulation on duct 1415 Piping Systems N.A. 1415.1 Piping insulation Indicate R -value of insulation on piping N.A. 1415.2 Radiant Systems Indicate R -value of insulation on radiant panels Yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist Continued MECH -CHK 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised July 2011 Project Address ALDO 'Date 4/30/2012 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the 2009 Seattle Energy Cocle. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Section 1416), continued 1416 Completion Requirements 1416.3.2 System Balancing Indicate air and water system balancing requirements 1416.3.3 Functional Testing Provide sequence of operations and test procedures. 1416.3.4 Documentation Indicate O&M manuals, record drawings, staff training 1416.3.5 Comm. Report Indicate requirements for final commissioning report 1416.4 Compliance Chklist Submit to building official upon substantial completion. SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. Yes 1441 Elec. water heater Indicate R -10 insulation under tank Yes 1442 Shut -off controls Indicate automatic shut -off of circulators or heat trace Yea 1443 Pipe Insulation Indicate R -value of insulation on piping No 1444 Pump Energy Indicate method of pump energy management (Sec 1438) 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. 1450 Heated Pools N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R -12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction COLD STORAGE (Sections 1460 -1465) 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. COMPRESSED AIR AND VACUUM PUMPS (Section 1470) 1470 Compressed Air and Vacuum N.A. 1470.1 Air compressor gnl. Indicate "no loss" water drains N.A. 1470.2 Rotary screw comp Indicate variable speed drive or other acceptable control COMMERCIAL FOOD SERVICE (Sections 1475) 1475 Commercial Food Service N.A. 1475 Food service equip. Indicate that equipment complies with energy and water efficiency criteria in Energy Star If "no" is indicated for any item in Sections 1401 -1424 or 1440 -1465 , provide explanation SE GO Cie PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -073 DATE: 07 -13 -12 PROJECT NAME: ALDO SHOES SITE ADDRESS: 657 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPART ENTS: U T building Division gm Public Works ❑ ' W4 Fire Prevention NE Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 07 -17 -12 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08-14-12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 HERMIT COORD COP* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -073 DATE: 05/04/12 PROJECT NAME: ALDO SHOES SITE ADDRESS: 657 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Building 'vision MI Public Works In �� �t*11 Fire Preven ion Structural Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 05/08/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 06 /05/12 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 02/29/12 PROJECT NAME: SITE ADDRESS: (g 7 rat( teko oats, PERMIT NO: I V 0=073 ORIGINAL ISSUE DATE: (p —( f5" L.& REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INICL S 1 — - ��( I- Summary of Revision: /4_&,\ GUS P1 eI e ; j ` ") `r- S 4cJc. 100 -s-, Received by: 044s Rot 7eLtiks REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) Citylf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http: / /www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: % /425 /2-- Plan CheclaPermit Number: ti‘ 1 r� 7 3 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # l after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: A L t7 0 Project Address: 6'57 c/�,`�-�G.2h 4-e - . r'- I( ' �f Contact Person Ar f s 1 L) . Phone Number: 550+ i� /' 5876 Summary of Revision: RECEIVED ere( OF TUKWILA IJUL 1i,3 ZUIZi PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: VI- Entered in Permits Plus on "1 ` 1 J- H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Revision Submittal.doc Revised: May 2011 Contractors or Tradespeople liter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name SAJO INC Phone 5143850333 Address 1320 Graham Blvd Suite /Apt. City Mont -Royal State QC Zip H3P3C8 County Out Of Country Business Type Corporation Parent Company GUERRERA TEDESCHI INVESTMENTS UBI No. 601884767 Status Active License No. SAJOII *893CZ License Type Construction Contractor Effective Date 3/4/2011 Expiration Date 3/4/2013 Suspend Date Specialty 1 General Specialty 2 Unused r Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status CONSTSI0240TCONSTRUCTION SAJOINC Construction Contractor General Unused 9/30/1998 9/11/2012 Re Licensed Business Owner Information Name Role Effective Date Expiration Date GUERRERA, SALVATORE President 02/07/2011 Amount TEDESCHI, FRANCA Secretary 02/07/2011 66458312 TEDESCHI, NICOLA Vice President 02/07/2011 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 Travelers Cas li Surety Co SW1514(50008840) 04/12/2010 Until Cancelled $12,000.00 02/22/2011 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 CHART'S INS CO 66458312 12/01/2011 12/01/2012 $1,000,000.0011 /29/2011 2 Liberty Mutual Ins Co tb1b71072805060 11/01/2010 12/01/2011 $1,000,000.00 11/04/2011 1 Liberty Mutual Ins Co tb1b71072805060 11/01/2010 11/01/2011 $1,000,000.00 03/04/2011 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 06/18/2012 EXISTING. LANDLORD DUCTWORK AT 13' -I" AFF TO REMAIN EXISTING LANDLORD DUCTWORK AT I3' -4" AFF TO REMAIN DATE MAY 01, 2012 JUNE 04, 2012 JUNE 28, 2012 JULY 12, 2012 EMIS /ISSUED ALDO / SAJO / L.L., BID 4 PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR SITE CONDITION ISSUED FOR 51TE CONDITION (2ND RD) EXISTING;: VAV..AT,: 12:3.'.': : : :AhF .}...:.. TO REMAIN.; If PRINT DATE 2012 -07 -12 NEW Ibxl4 ISION I;OxI4 NL NEW IO "m NEW IO" 0 MECHANICAL PLAN SCALE: 1/4" = 1'--a" 2" WIDE MIN. DUCT STRAP 48" O.G. MAX. RIGID ROUND DUCT ELBOW EXTERNALLY INSULATED Mal METAL SUPPLY DUCT EXTERNALLY INSULATED VOLUME DAMPER (FOR FINAL BALANCE ADJJSTMENT) DIFFUSER TRIM FRAME CEILING DUCT DETAIL: SCALE: NOT TO SCALE MECHANICAL EQUIPMENT SCHEDULE EXISTING FAN POWERED BOX MIN. GI=M MAX. GFM VOLT/ REF. MARK MANUFACTURER MODEL # GI°M SETTING SETTING PHASt: ACCESSORIES �� NOTES INTEGRAL 3 kW HEAT I. RELOCATE L L. COMPATIBLE CONTROLS WHERE INDICATED. FP -I TITUS ATSQ -"i 2 i 2Oa STRIP 1 AIR DEVICE SCHEDULE tE "H" PRICE) PLAN MARK MODEL. # FACE SIZE NECK SIZE TYPE NOTES ASPD -31 24x24 SEE PLAN 5.6. CAN SPF FRAME ( ) ASGD 24x24 SEE PLAN 5.6. LAY -IN Q530 24x12 -- Rh. -- `- 520 24x24 -- R G. EGGGRATE a MECHANICAL NOTES 1. FIRST TWENTY FEET OF SUPPLY/RETURN DUCTWORK FROM/TO UNIT SHALL BE INSULATED INTERNALLY WITH I -1/2" ACOUSTICAL LINER. DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR. NOTES BY SYMBOL RELOCATE LANDLORD COMPATIBLE CONTROLS AT 43" AFF. VERIFY EXACT LOCATION PRIOR TO INSTAU.ATION. 0 PROVIDE NEW EXHAUST FAN AS SPECIFIED. CONNECT NEW S ",a EXHAUST DUCT TO EXISTING LANDLORD EXHAUST SYSTEM ABOVE. V CONTRACTOR SHALL FIELD VERIFY EXISTING VAV MEETS OR EXCEEDS THE MINIMUM REGUIREK NTS LISTED IN THE SCHEDULE ON THIS SHEET. REPAIR TO LIKE NEW CONDITION TO ENSURE FROPER AND DEPENDABLE OPERATION. PROVIDE ALTERNATE BID TO INSTALL. NEW AS 5PECIFIED IF NECESSARY. 2. FLEX DUCT SHALL BE PREINSULATED WITH I -1/2" THICK FIBERGLASS, I# DENSITY FLEXMASTER OR EQUAL PROVIDE SPIN -IN FITTING WITH INTEGRAL VOLUME DAMPER AT EACH TAP. MAXIMUM FLEX RUN - FIVE FEET (5' -09. 3. T.G.G. SHALL VERIFY EXACT LOCATION OF HVAC EQUIPMENT BEFORE FABRICATING DUCTWORK. 4. UPON COMPLETION OF CONSTRUCTION T.G.G. SHALL CLEAN GOIL'S, ADJUST BELTS, REFRIG. CHARGE AND REPLACE FILTER MEDIA TO OBTAIN MAXIMUM. EFFICIENCY. 2012 -01 -10 2012 -06 -28 2012 -05-50 2012 -05-30 2012 -05-24 DATE PER LANDLORD COMMENT PER FIELD CONDITIONS PER SAJO COMMENTS PER LANDLORD COMMENTS PER ALDO COMMENTS REVISION THIS DRAWING HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ALDO GROUP AND ITS ASSOCIATED COMPANIES TO EXPLAIN THE LAYOUT AND SERVICES REQUIREMENTS FOR THE TRADE FIXTURES OR TO EXPLAIN COMPANY CONSTRUCTION STANDARDS. ALL DIMENSIONS SHALL BE VERIFIED ON SITE, AU. ERRORS AND DISCREPANCIES SHALL RE REPORTED TO 1HE OWNER BEFORE PROCEEDING WITH THE WORK. NO DIMENSIONS SHOULD BE MEASURED ON THE DRAWING. DIMENSIONS AND AREAS ON THIS DRAWING ARE FOR INFORMATION ONLY 5. T.G.G. SHALL PAINT ALL DIFFUSERS AND GRILLES TO MATCH ADJACENT CEILING OR AS SPECIFIED IN ARCHITECTURAL DRAWINGS. b. PROVIDE BALANCING DAMPER AT DIFFUSER WHERE ACCESS IS LIMITED. 1. EXISTING DUCTWORK TO REMAIN AND BE REUSED WHERE POSSIBLE. VAV NOTES (3.14VAC WOW TO CGNFOR 1 TO ALL APPLICABLE STATE, LOCAL AND REGULATORY AGENCY CODE REQUIREMENTS. TAG. WALL USE LANDLOR) APPROVED AIR 'BALANCING CONTRACTOR t PROVIDE NEW DUCTWORK AS REQUIRED. T.G.G. SHALL GAP AND SEAL ALL UNUSED PORTIONS OF DUCTWORK AIRTIGHT. ANY NEW DUCTWORK SHALL BE FABRICATED FROM GALVANIZED SHEET METAL OR STAINLESS STEEL. FIBERGLASS DUCTWORK WILL NOT BE PERMITTED. NO PVC PIPING ALLOWED. don penn • consulting engineer 635 Westport Parkway Suite 800 Grapevine, Texas 76051 Phone: 817.410 -2858 Fax: 817 -251 -8411 FILE COPY \V1Y Plan review approval is motto and omissions" Approval of canstlu�►n documents does not authorize the violator' of any adopted code or ordnance. Receipt of approved n Blond sIsackno�dged: La • Vir AIR DEVICE SCHEDULE tE "H" PRICE) PLAN MARK MODEL. # FACE SIZE NECK SIZE TYPE NOTES ASPD -31 24x24 SEE PLAN 5.6. CAN SPF FRAME ( ) ASGD 24x24 SEE PLAN 5.6. LAY -IN Q530 24x12 -- Rh. -- `- 520 24x24 -- R G. EGGGRATE a MECHANICAL NOTES 1. FIRST TWENTY FEET OF SUPPLY/RETURN DUCTWORK FROM/TO UNIT SHALL BE INSULATED INTERNALLY WITH I -1/2" ACOUSTICAL LINER. DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR. NOTES BY SYMBOL RELOCATE LANDLORD COMPATIBLE CONTROLS AT 43" AFF. VERIFY EXACT LOCATION PRIOR TO INSTAU.ATION. 0 PROVIDE NEW EXHAUST FAN AS SPECIFIED. CONNECT NEW S ",a EXHAUST DUCT TO EXISTING LANDLORD EXHAUST SYSTEM ABOVE. V CONTRACTOR SHALL FIELD VERIFY EXISTING VAV MEETS OR EXCEEDS THE MINIMUM REGUIREK NTS LISTED IN THE SCHEDULE ON THIS SHEET. REPAIR TO LIKE NEW CONDITION TO ENSURE FROPER AND DEPENDABLE OPERATION. PROVIDE ALTERNATE BID TO INSTALL. NEW AS 5PECIFIED IF NECESSARY. 2. FLEX DUCT SHALL BE PREINSULATED WITH I -1/2" THICK FIBERGLASS, I# DENSITY FLEXMASTER OR EQUAL PROVIDE SPIN -IN FITTING WITH INTEGRAL VOLUME DAMPER AT EACH TAP. MAXIMUM FLEX RUN - FIVE FEET (5' -09. 3. T.G.G. SHALL VERIFY EXACT LOCATION OF HVAC EQUIPMENT BEFORE FABRICATING DUCTWORK. 4. UPON COMPLETION OF CONSTRUCTION T.G.G. SHALL CLEAN GOIL'S, ADJUST BELTS, REFRIG. CHARGE AND REPLACE FILTER MEDIA TO OBTAIN MAXIMUM. EFFICIENCY. 2012 -01 -10 2012 -06 -28 2012 -05-50 2012 -05-30 2012 -05-24 DATE PER LANDLORD COMMENT PER FIELD CONDITIONS PER SAJO COMMENTS PER LANDLORD COMMENTS PER ALDO COMMENTS REVISION THIS DRAWING HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ALDO GROUP AND ITS ASSOCIATED COMPANIES TO EXPLAIN THE LAYOUT AND SERVICES REQUIREMENTS FOR THE TRADE FIXTURES OR TO EXPLAIN COMPANY CONSTRUCTION STANDARDS. ALL DIMENSIONS SHALL BE VERIFIED ON SITE, AU. ERRORS AND DISCREPANCIES SHALL RE REPORTED TO 1HE OWNER BEFORE PROCEEDING WITH THE WORK. NO DIMENSIONS SHOULD BE MEASURED ON THE DRAWING. DIMENSIONS AND AREAS ON THIS DRAWING ARE FOR INFORMATION ONLY 5. T.G.G. SHALL PAINT ALL DIFFUSERS AND GRILLES TO MATCH ADJACENT CEILING OR AS SPECIFIED IN ARCHITECTURAL DRAWINGS. b. PROVIDE BALANCING DAMPER AT DIFFUSER WHERE ACCESS IS LIMITED. 1. EXISTING DUCTWORK TO REMAIN AND BE REUSED WHERE POSSIBLE. VAV NOTES (3.14VAC WOW TO CGNFOR 1 TO ALL APPLICABLE STATE, LOCAL AND REGULATORY AGENCY CODE REQUIREMENTS. TAG. WALL USE LANDLOR) APPROVED AIR 'BALANCING CONTRACTOR t PROVIDE NEW DUCTWORK AS REQUIRED. T.G.G. SHALL GAP AND SEAL ALL UNUSED PORTIONS OF DUCTWORK AIRTIGHT. ANY NEW DUCTWORK SHALL BE FABRICATED FROM GALVANIZED SHEET METAL OR STAINLESS STEEL. FIBERGLASS DUCTWORK WILL NOT BE PERMITTED. NO PVC PIPING ALLOWED. don penn • consulting engineer 635 Westport Parkway Suite 800 Grapevine, Texas 76051 Phone: 817.410 -2858 Fax: 817 -251 -8411 FILE COPY \V1Y Plan review approval is motto and omissions" Approval of canstlu�►n documents does not authorize the violator' of any adopted code or ordnance. Receipt of approved n Blond sIsackno�dged: EXHAUST FAN SCHEDULE PLAN MARK MANUFACTURER MODEL NO. G.F.M. S.P. HP VOLT NOTES EF -I GROAN QTRIIOL 100 .25" 1/4 120 a CEILING. FANS SHALL 9E FURNISHED WITH THE FOLLOWING AMICABLE: a. BAGKDRAFT DAMPER b. VIBRATION ISOLATION SUPPORT HANGERS G. ROOF JACK WITH 331RPSGREEN 1. USE ONLY LANDLORD SPECIFICATION VAV CONTROLS FOR THIS PROJECT. REFER TO TEMPERATURE CONTROL NOTES THIS SHEET FOR ADDITIONAL INFORMATION ON PROGRAMMING AND FINAL WIRING CONNECTIONS TO THE LANDLORD'S SYSTEM. 2. UTILIZE ONLY RIGID DUCTWORK UPSTREAM OF THE VAV BOX. PROVIDE FOUR EQUIVALENT DUCT DIAMETERS OF STRAIGHT DUCTWORK DIRECTLY UPSTREAM OF THE VAV BOX INLETS. S. T.G.G. SHALL MAINTAIN ALL LL RETURN AIR OPENINGS 114 DEMISING. WALLS TO ENSURE OPERATION OF U.. CENTRAL VAV SYSTEM. RECEIVED JUL 13 2012 PERMIT CENTER G R O U P E 2300 EMILE— BELANGER, MONTREAL QUEBEC, CANADA, H4R 3J4 TEL: (514) 747 -2536 FAX: (514) 747 -6504 PROJET /PROJECT: SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical la Electrical *Plumbing Gas Piping City of Tukwila 1SU�,, i, .TANG DIVISION ALDO . . SOUTHGENT R AESTF I ELI, SEATTLE, YASHINGTON REVISIONS No des shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. R: \AIDO \..Fitch \2012. Projects \12. 3243. SouthoenterMoll .Settle.WA \12.3243.M1.dwg PROJET NO. /PROJECT NO. 2161 ECHELLE /SCALE: CONCEPT, ANNEE /YEAR: AAO6 DESSINE /DRAWN: DA VERWFIE /CHECKED: BM PAGE: M —I • EXHAUST FAN SCHEDULE PLAN MARK MANUFACTURER MODEL NO. G.F.M. S.P. HP VOLT NOTES EF -I GROAN QTRIIOL 100 .25" 1/4 120 a CEILING. FANS SHALL 9E FURNISHED WITH THE FOLLOWING AMICABLE: a. BAGKDRAFT DAMPER b. VIBRATION ISOLATION SUPPORT HANGERS G. ROOF JACK WITH 331RPSGREEN 1. USE ONLY LANDLORD SPECIFICATION VAV CONTROLS FOR THIS PROJECT. REFER TO TEMPERATURE CONTROL NOTES THIS SHEET FOR ADDITIONAL INFORMATION ON PROGRAMMING AND FINAL WIRING CONNECTIONS TO THE LANDLORD'S SYSTEM. 2. UTILIZE ONLY RIGID DUCTWORK UPSTREAM OF THE VAV BOX. PROVIDE FOUR EQUIVALENT DUCT DIAMETERS OF STRAIGHT DUCTWORK DIRECTLY UPSTREAM OF THE VAV BOX INLETS. S. T.G.G. SHALL MAINTAIN ALL LL RETURN AIR OPENINGS 114 DEMISING. WALLS TO ENSURE OPERATION OF U.. CENTRAL VAV SYSTEM. RECEIVED JUL 13 2012 PERMIT CENTER G R O U P E 2300 EMILE— BELANGER, MONTREAL QUEBEC, CANADA, H4R 3J4 TEL: (514) 747 -2536 FAX: (514) 747 -6504 PROJET /PROJECT: SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical la Electrical *Plumbing Gas Piping City of Tukwila 1SU�,, i, .TANG DIVISION ALDO . . SOUTHGENT R AESTF I ELI, SEATTLE, YASHINGTON REVISIONS No des shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. R: \AIDO \..Fitch \2012. Projects \12. 3243. SouthoenterMoll .Settle.WA \12.3243.M1.dwg PROJET NO. /PROJECT NO. 2161 ECHELLE /SCALE: CONCEPT, ANNEE /YEAR: AAO6 DESSINE /DRAWN: DA VERWFIE /CHECKED: BM PAGE: M —I rEXISTING LANDLORD DUCTWORK AT 1S1-I° AFF TO REMAIN ■ /I I ., •, i „ .11 f I i • it • , ; ,. . a EXISTIWV.ANI:AT-..12`...a.!:::AFF:-.. to REMAIN.' REFER TO M-1111:' „ tt • It t 1 ; i i t 1 1 1 I t t 1 .t, • . t „ : t t EXISTING LANDLORD DUCTWORK AT 15'-4" APP TO REMAIN • • ^ • , . I • • • • • t • , • . • • • • • .• i4Ssi..-J. 0 1 11 . (j) 11 I t.; ‘1; ';;•; cs tt, :1 i •••i , t ii ! t • P: 'A . : i . 1 . 4 ,t .. . . s ' . .... .. ... ..... 1 ti II ......1 - • • • ..y•• -,•.•-• -••••., • , •••• • • • j) • • • •••• ..• • .1 .• • • .1 •,-, ••., H 2.. • r • ,. .• (1 '' I I (114, . .II . I ! I ". 1::.:..i i,: ':;j c .■!. ? I Ii III , i ...,;..,,!I ' k..K,7, :i , 9 \ r4 "NM 7, i C i f . t I t 1 i „1 : 1 !t I i ' i. t ..:...:.1...7... , ,..,i I ! I , i . . . f 1:3 r/f,ft "Arm .2TR; EL E3 0 0 NL m MECHANICAL DEMOLITION PLAN SCALE: 1/4" = 1b-0" DEMO NOTES 1. EXISTING DUCTWORK AND DIFFUSERS TO ESE REMOVED A5 NOTED. 2. REMOVE ALL EXISTING MECHANICAL. EQUIPMENT, DUCTWORK, PLUMBING FIXTURES AND PIPING SYMMS ETC. NOT BEING REUSED. DO NOT JJST ABANDON. NOTES BY SYMBOL 0 EXISTING GRILLES AND ASSOCIATED BRANCH DUCT INDICATED ARE TO BE DEMOLISHED 0 MECHANICAL CONTRACTOR TO UTILIZE AS MUCH EXISTING DUCTWORK AS POSSIBLE IF IT MEETS SIZES SHOWN ON M-I REGARDLESS OF WHAT IS SHOWN TO BE DEMOLISHED ON THIS PLAN. VERIFY IN FIELD ACTUAL. EXISTING SIZES . REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 0 2m2 City of Tukwila BUILDING DIVISION REVISIONNO.1. MuO73 4 RECEIVED JUL 1 3 2012 PERMIT CENTER R: \ALDO\._Fitch\2012.Proslects\l2.3243.SouthcenterMall.Settle.WA\12.3243,M1A.dwg ALDO DATE EMIS/ISSUED MAY 01, 2012 ALDO / SAJO / L.L., SID 4 PERMIT JUNE 04, 2012 ISSUED FOR CONSTRUCTION JUNE 25, 2012 ISSUED FOR SITE CONDITION JULY 12, 2012 ISSUED FOR SITE CONDITION (2ND RD) PRINT DATE: 2012-07-12 5 2012-01-10 PER LANDLORD COMMENT 4 2012-06-2S PER FIELD CONDITIONS 5 2012-05-50 PER SAJO COMMENTS 2 2012-05-50 PER LANDLORD COMMENTS 2012-05-2q PER ALDO COMMENTS NO. DATE REVISION MIS DRAWING HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF 1HE ALDO GROUP AND ITS ASSOCIATED COMPANIES TO EXPLAIN THE LAYOUT AND SERVICES REQUIREMENTS FOR THE TRADE FIXTURES OR TO EXPLAIN COMPANY CONSTRUCTION STANDARDS. ALL DIMENSIONS SHALL BE VERIFIED ON SIIE. ALL ERRORS AND DISCREPANCIES SHALL BE REPORTED TO THE OWNER BEFORE PROCEEDING WITH THE WORK NO DIMENSIONS SHOULD BE MEASURED ON 1HE DRAWING. DIMENSIONS AND AREAS ON MIS DRAWING ARE FOR INFORMATION ONLY d p c e don penn a consulting engineer 635 Westport Parkway Suite 300 Grapevine, Texas 76051 Phone: 817-410-2858 Fax: 817-251-8411 ALDO G R OUPE 2300 EMILE—BELANGER, MONTREAL QUEBEC, CANADA, H4R 3J4 TEL.: (514) 747-2536 FAX: (514) 747-6504 PROJET/PROJECT: ALDO SOUTHCENTEIR !NSW IUD SEATTLE, INASHIN&TON TITRE/TITLE: MECHANICAL DEMOLITION PLAN PROJET NO./PROJECT NO. 2161 ECHELLE/SCALE: DESSINE/DRAWN: VERIFIE/CHECKED: BH CONCEPT, ANNEE/YEAR: AAOb PAGE: M.' I A MECHANICAL SPECIFICATIONS 15100 - GENERAL PRESCRIPTIONS 1.0 GENERAL NOTE 1.I THE COMPLETE INSTALLATION SHALL BE MADE 114 STRICT ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS. CONSULT LANDLORD'S DESIGN CRITERIA. L2 THE DRAWINGS AND THE SPECIFICATIONS SHAD. BE CONSIDERED ADDITIONAL TO ARCHITECT AND ELECTRICAL ENGINEER'S SPEGIFIGATIONS. ANY DISCREPANCY OR CONTRADICTION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. 1.3 ARCHITECTS GENERAL. REQUIREMENTS ARE PART OF THIS CONTRACT AND THEY SHALL 5E APPLIED BY THE GENERAL CONTRACTOR AND SUBCONTRACTORS (HVAG- PLUMBING -FIRE PROTECTION etc.). 1.4 GENERAL CONTRACTOR SHALL VISIT THE J08 SITE IN ORDER TO FAMILIARIZE HIMSELF WITH CONDITIONS THAT CAN AFFECT HIS WORK IN ANY MANNER. (MEASUREMENTS - PARTICULAR CONDITIONS, ETC...) NO EXTRA COST DUE TO THE IGNORANCE OF LOCAL CONDITIONS WILL BE ACCEPTED BY THE OWNER. 15 DUCTWORK, PIPING, EQUIPMENT AND ACCESSORIES ARE SHOWN SCHEMATICALLY. NO DIMENSION SHALL BE SCALED ON THE DRAWINGS. GIVE PRIORITY TO THE DIMENSIONS MARKED ON THE DRAWINGS. 1.6 GENERAL CONTRAGTOR SHALL MAKE AU. NECESSARY CHECKING AND ADJUSTMENTS TO COMPLY WITH THE INTENT OF SPECIFICATIONS. 1.1 THE DRAWINGS SHOW THE APPROXIMATE LOCATION OF THE EQUIPMENT. EACH SUBCONTRACTOR SHALL VERIFY THESE LOCATIONS BEFORE INSTALLATION. 1.8 BEFORE STARTING THE WORK, COORDINATE ALL SUBCONTRACTOR WORK. NO EXTRA COST WILL BE ACCEPTED FOR A LAGK OF COORDINATION. 1.4 GENERAL. CONTRACTOR'S TENDER SHALL INCLUDE THE COST OF ALL NECESSARY PERMITS AND GERTIFIGATES, ALL DRAWINGS APPROVAL COSTS AND ALL INSPECTION COSTS REQUIRED BY ALL AUTHORITIES HAVING JURISDICTION. 1.10 EACH SUBCONTRACTOR SHALL COMPLETE THE WORK IN EVERY DETAIL. EVEN THOUGH NOT SHOWN 014 DRAWINGS OR GALLED FOR IN THIS SPECIFICATION. 1.11 ALL RUBBISH'S AND GARBAGE SHALL BE REMOVED FROM THE JOB SITE AT THE END OF EVERY WORKDAY. AT THE CONTRACT COMPLETION, ALL TOOLS AND EQUIPMENT SHALL BE REMOVED AND THE JOB SITE SHALL SE LEFT IN A GLEAN CONDITION.. 1,12 STARTUP SHAH BE DONE BY MECHANICAL SUBCONTRACTOR AND THE GENERAL CONTRAGTOR 1.13 COMPLY WITH ALL APPLICABLE CODES. 114 ALL WORK AFFECTING OTHER TENANTS SHALL BE DONE OFF mimeo HOURS (NIGHT OR WEEKEND). COORDINATE WITH THE LANDLORD. 2.0 GUARANTEE 21. EACH SUBCONTRACTOR SHALL GUARANTEE HIS WORK FOR ONE YEAR AFTER DATE OF PROVISIONAL ACCEPTANCE BY THE TENANT. EACH SUBCONTRACTOR SHALL REPAIR OR REPLACE AT HIS OWN EXPENSE, ALL DEFECTS SHOWING DURING GUARANTEE PERIOD, AND THIS, WITHIN 48 HOURS FROM NOTICE. 2.2 PROJECTS IMPLYING AIR CONDITIONING COMPRESSORS SHALL INCLUDE AN EXTENDED FOUR (4) YEARS WARRANTY PERIOD COVERING COMPRESSORS. 3.0 SHOP DRAWINGS AND INSTRUCTION MANUALS. 3.1 PRIOR TO ORDERING OR INSTALLING ANY EQUIPMENT, SUBMIT TO ENGINEER FOR APPROVAL A MINIMUM OF TO (2) COPIES OF SHOP DRAWINGS FOR E..AGH ITEM OF EQUIPMENT, IF REQUESTED. 3.2 UPON COMPLETION OF CONTRACT, SUBCONTRACTOR SHALL SUPPLY INSTRUCTION MANUALS, COVERING OPERATION AND MAINTENANCE OF EQUIPMENT INCLUDED IN HIS CONTRACT. INSTRUCTION MANUALS SHALL BE SUPPLIED 114 LOOSE LEAF BINDER, IN THREE (9) COPIES. (ONE (I) DOPY FOR THE LANDLORD AND TWO (2) FOR THE TENANT). INSTRUCTION MANUALS SHALL INCLUDE: 0. ALL GUARANTEES ON EQUIPMENT AND INSTALLATIONS. b. TESTS RESULTS AND AIR BALANCE REPORT. G. OPERATION AND MAINTENANCE MANUALS. d. SPRINKLERS ACCEPTANCE CERTIFICATE AS PER N12PA -13. 4.0 ALTERNATE EQUIPMENT 4.1 PROPOSAL SHALL BE BASED ON SPECIFIED EQUIPMENT AND MATERIAL. 4.2 PROPOSAL FOR ALTERNATE TO SPECIFICATION SHALL INCLUDE MANUFACTURER NAME, MODEL AND COST MODIFICATION. 4.3 COST OF ANY CHANGE REQUIRED TO OTHER TRADES WORK DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT, SHALL BE INCLUDED IN THE SUBCONTRACTORS PROPOSAL GALLING FOR TH15 SUBSTITUTION. EVEN IF THESE CHANGES APPEAR AFTER THE DEMAND FOR SUBSTITUTION. 4.4 ALTERNATE PROPOSALS WILL 13E ACCEPTED OR REJECTED BEFORE CONTRACTS ARE AWARDED. 140 CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED. 5.0 DRILLING AND ACCESS DOORS 5.1 OBTAIN AUTHORIZATION FROM BUILDING LANDLORD BEFORE DRILLING ANY HOLE 114 CEILINGS, SLABS, OUTSIDE WALLS, TENANTS WAILS OR FIRE RETARDING WALLS, 5.2 OPENINGS, PAINTING, GUTTING AND PATCHING OF HOLES IN WALLS AND SLABS, SHALL BE MADE BY THE GENERAL CONTRACTOR 5.3 ALL RECESSED FRAMES AND ACCESS DOORS, FIRE RETARDING ACCESS DOOM 114 WALLS AND GEILIN65, MALL BE SUPPLIED BY THE CONCERNED SUBCONTRACTOR AND INSTALLED BY THE 6,ENERAL CONTRACTOR. THEY SHALL BE INSTALLED I ERE REQUIRED. THE SUBCONTRACTOR SHALL DETERMINE THE LOCATION 114 ACCORDANCE WITH THE ARCHITECT. 6.0 DEMOLITION 6.1 EVERY SUBCONTRACTOR OF E..AGH SECTION SHALL. EXECUTE DEMOLITION WORK DESCRIBE ON DRAWINGS, AND THOSE NEEDED TO COMPLETE CONTRACT ADEQUATELY. 6.2 UNLESS OTHERWISE INDICATED, ALL REMOVED AND UNUSED MECHANICAL EGUL1'MIENT SHALL BE TURNED TO THE LANDLORD. 15400 - FIRE PROTECTION 1.0 WORK INCLUDES GENERALLY, LABOR, SUPPLY AND INSTALLATION OF ALL MATERIALS AND EQUIPMENT REQUIRED FOR THE FIRE PROTECTION WORK INDICATED IN DRAWINGS AND SPECIFICATIONS. 2.0 THE TENANT'S FIRE PROTECTION SUBCONTRACTOR SHALL VISIT THE SITE IN ORDER TO WHITENESS ALL EXISTING CONDITIONS AND SUBMIT A DETAILED REPORT TO THE TENANT, DESCRIBING ALL PEFEGTS IN EXISTING INSTALLATION. 3.0 INSTALLATION SHALL CONFORM TO ALL STANDARDS AND REGULATIONS REGARDING T14I5 TYPE OF CONTRACT TYPE, AND SHALL SE APPROVED BY THE AUTHORITIES HAVING JURISDICTION. TO EE COORDINATED BY THE WILDING LANDLORD AS PER NFPA 13, LAST EDITION. 4.0 CONTRACTOR SHALL BE LICENSED FOR EXECUTION OF THIS TYPE OF WORK. 5.0 ALL MATERIALS SHHAL. BE FM, ULNLG LISTED, AND MEET ALL REGENT PUBLISHED REGULATIONS. 6.0 FIRE PROTECTION SUBCONTRACTOR SHALL MAKE SURE THAT INSPECTION OF HIS INSTALLATION 15 MADE, BEFORE IT IS CONGEALED BY GEILIN6 AND COVERING. 7.0 AT FINAL INSPECTION BY THE AUTHORITIES HAVING JJRI$DIGTION, THE FIRE PROTECTION SUBCONTRACTOR SHALL MAKE ALL REQUIRED CHANGES, NECESSARY TO OBTAIN FINAL. APPROVAL 8.0 THE FIRE PROTECTION SUBCONTRACTOR SHALL OBTAIN A CERTIFICATE OF INSPECTION FROM AUTHORITIES HAVING JURISDICTION, AND TURN IT TO THE LANDLORD BEFORE FINAL APPROVAL. 4.0 AUTHORITIES HAVING JURISDICTION, SHALL APPROVE DESIGN DRAWINGS, COMPLETE INSTALLATION, EQUIPMENT AND MATERIALS, INSPECT THEM AND SUPERVISE TESTS. (FIRE PROTECTION SUBCONTRACTOR SHALL PAY ALL COSTS AND FEES). 10.0 PREPARE ALL INSTALLATION DRAWINGS, DETAILS AND HYDRAULIC CALCULATIONS NECESSARY TO OBTAIN APPROVAL FROM CONCERNED AUTHORITIES, BEFORE WORK IS STARTED. (T=IRE PROTECTION SUBCONTRACTOR TO PAY FOR ALL FEES AND COSTS INVOLVED). DIVISION 15000 15400 - FIRE PROTECTION (CONTINUED) 110 DRAWINGS SHALL INDICATE IN CLEAR MANNER: a. LOCATION OF THE BUILDING b. ADDRESS OR ANY OTHER MEANS FOR DESIGNATION OF THE WILDING G. HAZARD ZONE SCHEDULE d. FIRE PROTECTION SUBCONTRACTORS NAME AND ADDRESS 0. AUTHORITIES HAVING JURISDICTION NAME F. THE SYSTEM DESIGN GRITS RIAS SUCH AS HAZARD TYPE, MINIMUM FLOW RATE AND THROW OF EACH SPRINKLER HEAD g TOTAL REQUIRED WATER FLOW, INCLUDING INSIDE FIRE HOSE CABINETS, AND OUTSIDE FIRE HYDRANTS h. WATER SUPPLY INFORMATION I. SUPPLY ONE (I) SEPIA AND TWO (2) COPIES, SCALE I /4" = (1:50) OF INSTALLATION DRAWINGS. 12.0 THE ROOM 15 CLASSIFIED ORDINARY HAZARD. EACH SPRINKLER HEAD SHALL DOVER 130 sgFt (12.1m ) MAXIMUM. TO BE COORDINATED WITH THE LANDLORD. 15.0 SEMI- LOGARITHMIGS TYPE GRAPHICS SHALL INCLUDE WATER SUPPLY CURVES, SYSTEM REQUIREMENTS, EXTERIOR AND INTERIOR HOSES REQUIREMENTS, IN SUCH A MY AS TO PRESENT A GRAPHIC RESUME OF HYDRAULIC CALCULATIONS. 14D PIPING AND FITTINGS SHALL BE APPROVED TYPE, IN COMPLIANCE WITH NFPA CODE, FM OR ULG IDENTIFIED AND DESIGNED TO WITHSTAND A WORKING PRESSURE OF 115 Ib /sgin (12I0KP0). 15.0 FIRE PROTECTION SUBCONTRACTOR SHALL INSTALL ALL VALVES SHOWN 014 DRAWINGS AND AS NECESSARY FOR THE PROPER OPERATION OF THE INSTALLATION AND AS REQUESTED BY NFPA. 16.0 ELBOWS, REDUCERS, ADAPTERS, FITTINGS AND COUPLINGS SHALL EE SAME MANUFACTURE AS TEES. 1 ?.0 PIPING $HALL BE BLACK STEEL, SCHEDULE 40, ASTM -A53, ASTM -A135 AND ASTM -A 158. THREADED JOINTS, CAST IRON FITTINGS ASTM- A126,125 lblsgh, (860KP0) BY GRINNELL, UL APPROVED, THREADED, HYDROSTATIC, WORKING PRESSURE OF 115 Ib /sgln (I210KPa) AT 1507 (66'G) AND LESS. FLANGES PACKING, TUBE RUBBER, ALBION 850, I /8" (3.2m n). 18.0 RUNS OF PIPE AND EQUIPMENT LOCATION ARE SHOWN APPROXIMATE. FIRE PROTECTION SUBCONTRACTOR SHALL COORDINATE 1415 INSTALLATION WITH THE CEILING, DUCTS, WONTING AND GENERAL. LOOK OF THE WORK. 140 FLUSHING CONNECTIONS SHALL BE INSTALLED AT LOW POINTS WHERE REQUIRED AND WHERE INDICATED 014 DRAWINGS, N SUCH A WAY AS TO EMPTY THE SYSTEM COMPLETELY. 20.0 ALL SPRINKLERS SHALL BE OF AN APPROVED F06 TYPE WITH FUSE MELTING AT A VARIOUS TEMPERATURES ACCORDING TO THE REQUIREMENTS. 210 PENDANT SPRINKLER HEAD: MICROMATIG, MODEL WITH GLASS FUSE (E -I), SEMI - RECESSED, CHROMED PLATED ESCUTCHEON AND SPRINKLER, OR ALTERNATE APPROVED EQUIPMENT. 22.0 UPRIGHT SPRINKLER HEAD; MlGROMATIG, MODEL WITH GLASS FUSE (M), BRONZE FINISH. OR ALTERNATE APPROVED EQUIPMENT. 23.0 INVISIBLE SPRINKLER HEAD: STAR, MODEL H ( "UNSPOILT RN), FULLY RECESSED IN CEILING AND HIDE WITH 4" DIAMETER PLATE OR ALTERNATE APPROVED EQUIPMENT. 24.0 REMOVED SPRINKLER HEADS SHALL NOT BE REUSED. 25.0 FIRE PROTECTION SUBCONTRACTOR SHALL INSTALL SPRINKLER GUARDS IN LOCATION WHERE SPRINKLERS MAY SE SUSJEGT 70 MEGHANIGAL IMPACTS AND WHERE INDICATED 014 DRAWINGS. 26.0 FIRE PROTECTION SUBCONTRACTOR SHALL INSTALL EVERYWHERE PIPES RUN THROUGH WALLS, FLOORS, CEILINGS ETC,.. A CAST IRON ESGUTGIEON ON EACH SIDE OF THE PARTITION. FIG 3x15 OF GRINNELL OR ALTERNATE APPROVED EQUIPMENT. 21.0 FIRE PROTECTION SUBCONTRACTOR SHALL INSTALL EVERYWHERE PIPES RUN THROUGH ACOUSTICAL CEILINGS, CHROMED STEER.. ESCUTCHEON WITH CLAMPING MECHANISM, AND CONGEALED HINGES, FI620 OF GRINNELL, OR ALTERNATE APPROVED EQUIPMENT. 28.0 FIRE PROTECTION SUBCONTRACTOR SHALL COORDINATE WITH LANDLORD'S UNDERWRITERS THE ADDITION OF SPRINKLER HEADS OVER FINISHED CEILING. 24.0 FIRE PROTECTION SUBCONTRACTOR SHALL SUPPLY AND INSTALL TWO (2) PORTABLE FIRE EXTINGUISHERS, ABC PRY POWDER, PRESSURE TYPE, GLASS 6A, 80136, 10 POUNDS (4.5 K6) CAPACITY, 235 Ib /ssqq,,In (1620 KPa) WORKING PRESSURE. MODEL VEDL -ABGIO OF GFH, WALL INSTALLATION, OR ALTERNATE APPROVED EQUIPMENT. 15500 - VENTILATION- HEATING -AIR CONDITIONING 1.0 WORK INCLUDES GENERALLY, LABOR, SUPPLY AND INSTALLATION OF ALL MATERIALS AND EQUIPMENT REQUIRED FOR THE VENTILATION WORK INDICATED IN DRAWINGS AND SPECIFICATIONS. 2.0 THE TENANT'S VENTILATION SUBCONTRACTOR SHALL VISIT THE SITE IN ORDER TO WHITENESS ALL EXI5TI146 CONDITIONS AND SUBMIT A DETAILED REPORT TO THE TENANT, DESCRIBING ALL DEFECTS 114 EXISTING INSTALLATION, 3.0 THE LANDLORD'S VENTILATION SUBCONTRACTOR SHALL VERIFY ALL HVAG UNITS AND THE TENANT'S VENTILATION SUBCONTRACTOR SHALL PERFORM THE NECESSARY CORRECTIONS WITHOUT BEING LIMITED TO, a. BALL BEARINGS LUBRICATION. b. COILS, GLEANING AND PURGING. G. FANS: REPLACE BELTS, ALIGNMENT IF REQUIRED. d. REPLACE FILTER MEDIA. 0. CHECK REFRIGERANT CHARGE. F. CHECK WIRING AND CONTROLS. g. CONDENSER AND ACCESSORIES GLEANING. h. PERFORM BALANCING WORK AND SUPPLY A BALANCING REPORT To OMER AND TENANT. 4.0 THE VENTILATION SUBCONTRACTOR SHALL ADJUST THE AIR QUANTITIES OF UNITS A5 PER DRAWINGS AND SPECIFICATIONS. 5.0 THE VENTILATION SUBCONTRACTOR SHALL VISIT THE JOB SITE TO MAKE SURE OF THE EXACT LOGATION OF NEW DUCTS, GRILLES AND DIFFUSERS. HE SHALL ALSO SUPPLY SHOP DRAWINGS TO THE TENANT BEFORE FABRICATION AND INSTALLATION. 6.0 THE EXACT LOCATION OF GRILLES AND PIER/MRS SHALL BE MADE 114 ACCORDANCE WITH THE LAST ISSUED REFLECTED CEILING PLAN. TO BE COORDINATE WITH ARCHITECT. 1.0 WHEN REQUIRED, SMOKE DETECTORS SHALL BE SUPPLIED AND INSTALLED BY VENTILATION SUBCONTRACTOR. 8.0 THE VENTILATION SUBCONTRACTOR SHALL VERIFY AND REPAIR THE EXISTING DUCTS INDICATED 014 DRAWINGS. INCLUDING ACOUSTICAL AND THERMAL INSULATION. 4.0 NEW DUCTS SHALL BE MADE OF GALVANIZED STEEL CLICCT. CONNECTIONS AND INSTALLATION INCLUDING JOINTS AND ANCHOR GASES AS PER ASHRAE/SMAGNA REQUIREMENTS. DIMENSIONS INDICATED 014 DRAWINGS ARE INTERNAL DIMENSIONS. 10.0 MANUFACTURED FLEXIBLE DUCTS FROM "SIMPLE FLEX" OF A MAXIMUM OF FIVE (5) FEET (I500mm) IN LENGTH, TO BE INSTALLED AT .THE INLET OF AIR TERMINAL UNITS, DIFFUSERS, ETC. 11.0 THE TENANT SHALL INDICATE 1'0 THE VENTILATION SUBCONTRACTOR, THE EXACT NEW LOCATION OF THE EXISTING THERMOSTAT. ALL. CONTROLS COMPONENTS SHALL EE VERIFIED. 12.0 IAIHEN REQUIRED, INSTALL FIRE DAMPERS WHERE INDICATED 014 DRAWINGS. FIRE DAMPERS IN ACCORDANCE WITH NFPA -10M0B STANDARDS. ULG LISTED. a. RECTANGULAR DUCTS: RECTANGULAR COLLAR , TYPE '8' WITH 140 AIR STREAM INTERFERENCE. 114 SPECIAL GASES WHERE VERTICAL SPADE 15 LIMITED TYPE 'A' MAY BE AGGEPTASLE. b. ROUND DUCTS : CIRCULAR DOLLAR, GR TYPE WITH NO AIR STREAM INTERFERENCE. 13.0 SUPPLY AND INSTALL. MANUAL DAMPERS WHERE INDICATED ON DRAWINGS. SINGLE OR MULTIPLE BLADE DAMPERS, OPPOSED BLADE TYPE, MANUALLY ADJUSTABLE FOR AIR FLOW ADJUSTMENT. 15700 - ACOUSTICAL AND THERMAL INSULATION 1.0 GENERAL NOTES 1.1 WORK INCLUDES GENERALLY, LABOR, SUPPLY AND INSTALLATION OF ALL MATERIALS AND EQUIPMENT REQUIRED FOR THE INSULATION WORK INDICATED 114 DRAWINGS AND SPECIFICATIONS. 1.1 WORK INCLUDES GENERALLY, LABOR, SUPPLY AND INSTALLATION OF ALL MATERIALS AND EQUIPMENT REQUIRED FOR THE INSULATION WORK INDICATED IN DRAWINGS AND SPECIFICATIONS. 2.0 PLUMBING 2.1 INSTALL I" (25.4n1m) THERMAL INSULATION ON DOMESTIC WATER PIPING UP TO PLUMBING FIXTURES. RESIN IMPREGNATED GLASS FIBER. 2.2 MOLDED FIBERGLASS BONDED WITH BAKED RESIN, WITH ALUMINUM COVERING AND OUTSIDE WHITE 191415H. MAXIMUM THERMAL CONDUCTIVITY OF 0.24 BTU- INh -fta-T (0.03511/m'G) AT 75.27 (24 t). JOINTS SHALL BE COVERED WITH STRIPS OF ALUMINUM FOIL, SEAL WITH VAPOR PROOF ADHESIVE. 3.0 VENTILATION 3.1 INSTALL ACOUSTICAL INSULATION WHERE REQUESTED IN THE SPECIFICATION. FLEXIBLE INSULATION CONFORM WITH NFPA 40, 2 Ib/ft° (32 K6 /m°) OF DENSITY FOR I /2" (I3nm) THICKNESS AND 1.5 lb/ft° (24.03 KG /m ) FOR OTHER THICKNESS. CLOVER SIDE EXPOSED To AIR STREAM WITH BLACK CANVAS. 32. INSTALL ACOUSTICAL INSULATION ON HVAG UNITS SUPPLY DUCT FOR TEN (10) FEET (am) IN LENGTH. 5.5 INSTALL ACOUSTICAL INSULATION ON HVAG UNITS RETURN DUCT FOR TEN (10) FEET (3m) IN LENGTH FROM UNITS. 3.4 INSTALL THERMAL INSULATION WHERE REQUESTED IN THE SPECIFICATION. RI612 FIBERGLASS BLANKET OF 3Ib/ft8 (48KG /m °) OF DENSITY, MAXIMUM CONDUCTIVITY OF 0.23 131)- In/h- Ft' -'F (0.033W/m'G) AT 15.2'F (24 G) WITH TYPE RFFRK VAPOR BARRIER. 5.5 INSTALL THERMAL INSULATION 014 ALL TOILET EXHAUST AIR DUCTS WHEN CONNECTED TO AIR EXHAUSTS. + COOLING OA DB COOLING IA DB • HEATiG OA + ROOF U- FACTOR + LIGHT DIVERS VAV MIN :AIR • LTS- ,SURFACE • %LETS- SURFACE • WALL .AREA + %R.00FTO SPACE PEOPLE SENS HEAT ALDO Southcenter Mall Seatt 'e, WA 235 SQUARE FEET A.3HRiE DESIGN CONDITIONS SENSIBLE HEAT GAIN PEOPLE VENTILATION ROOF LOAD LT$- SURFACE LT$- RECESSE0 MIEIC LOAD WALL LOAD TOTAL SENSIBLE 250 • COOLING OA WB COOLING IA W$ HEATING IA LTS- RECESSED %LTS- RECESSED MI SC. WATTS SO FT /PERSON NO OF PEOPLE WALL U- FACTOR PEOPLE LATENT COOLING LOAD SUMMARY LATENT HEAT GAIN 7833 .PEOPLE 0 VENTILATION 0 70% TO SPACE 100% TO SPACE 70% TO SPACE '11644 '15659 10239 0 45375 TOTAL COOLING LOAD SEI14SUTHDTAL RA1I0 . NOMINAL CFM (15 DEG F UFO + SUPPLY AIR TEMP TEMPERATURE DIFFERENCE SENSIBLE HEATGAI VENTILATION ROOF LOAD WALL LOAD TOTAL SENSIBLE 1111.1`W 1111,1MPIRM TOTAL LATENT 5 [642 BTIJH SS To 2212 CFM DEG F 1$DEGF HEATING LOAD SUM 0 0 4 ARY LATENT' HEAT GAIN V ENTILATION TOTAL LATENT TOTAL HEATING LOAD NOMINAL KW ELEC HEAT IMNIMUM KW ELEC HEAT {EASED ON 20 DEG F RISE 63 70 200 6267 0 6267 0 BTLIfi 0 KW 2 KW VAV MIN AIR) 0 0 3.6W /SOFT 0,98 CFMISQ FT 22 BTLUH /SQ FT 4.3 TONS 546 SO FUTON LEGEND t=2] CiP 1 t� f CFM E.1.30)^1 WITH TURNING VANES SUPPLY DUCT RETURN OR EXHAUST DUCT TAKE -OFF WITH BOOTH MANUEL DAMPER TRANSFORMATION FROM RECTANGULAR DUCT TO FLEXIBLE DUCT ELECTRICAL COIL THERMOSTAT VENTILATION GRILLE TYPE CUBIC FEET PER MINUTE CUBIC FEET PER MINUTE DUCT TO BE DEMOLISHED REVIEWED FOR CODE COMPLIANCE APPROVED APP JUL 2 0 2012 City of Tukwila BUILDING DIVISION REVISION:NOLL 4POJ3 RECEIVED JUL 13 2012 pERM1T CENTER R: \ALDO\) itch \2012.Projecte \12. 3243. SouthcehterMall .Settle.WA \12.3243.M2.dwg ALDO DATE EMIS /ISSUED MAY 01, 2012 ALDO / SAJO / L.L., BID H' PERMIT JUNE 04, 2012 155UED FOR CONSTRUCTION JUNE 28, 2012 ISSUED FOR SITE CONDITION JJLY 12, 2012 ISSUED FOR SITE CONDITION (2ND RD) PRINT DATE 2012 -07 -12 5 2 NO. 2012 -01 -10 2012 -06 -2S 2012 -05-50 2012 -05-50 2012 -05-24 DATE PER LANDLORD COMMENT PER FIELD CONDITIONS PER SAJO COMMENTS PER LANDLORD COMMENTS PER ALDO COMMENTS REVISION THIS DRAWING HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ALDO GROUP AND ITS ASSOCIATED COMPANIES TO EXPLAIN 1HE LAYOUT AND $ERVICES REQUIREMENTS FOR THE 1RADE FIXTURES OR TO EXPLAIN COMPANY CONSTRUCTION STANDARDS. ALL DIMENSIONS SHALL BE VERIFIED ON SITE. ALL ERRORS AND DISCREPANCIES SHALL BE REPORTED TO THE OWNER BEFORE PROCEEDING WITH THE WORK. NO DIMENSIONS SHOULD BE MEASURED ON THE DRAWING. DIMENSIONS AND AREAS ON THIS DRAWING ARE FOR INFORMATION ONLY d V e don penn • consulting engineer 635 Westport Parkway Suite 300 Grapevine, Texas 76051 Phone: 817 -410 -2858 Fax: 817 -251 -8411 ALDO G R O U P E 2300 EMILE - BELANGER, MONTREAL QUEBEC, CANADA, H4R 3J4 TEL.: (514) 747-2536 FAX: (514) 747 -6504 PROJET /PROJECT: ALDO SOUTHCENTER WESTF1 E11, SEATTLE, WASHINGTON TITRE /TITLE: MECHANICAL SPECIFICATIONS PROJET NO. /PROJECT NO. 2167 DESSINE /DRAWN: DA ECHELLE /SCALE: VERIFIE /CHECKED: BH CONCEPT, ANNEE /YEAR: AAO6 PAGE: M -2 2" WIDE MIN. DUCT STRAP 48" O.G. MAX. RIGID ROUND METAL DUCT EXTERNALLY INSULATED RIGID ROUND DUCT ELBOW EXTERNALLY INSULATED INSULATED FLEXIBLE DUCT MAX. LENGTH 5'-0" VOLUME DAMPER (FOR FINAL BALANCE ADJJSTMENT) DIFFUSER TRIM FRAME METAL SUPPLY DUCT EXTERNALL INSULATED 7 EXISTING LANDLORD .DUCTWORK AT I3' -I" AFF TO REMAIN EXISTING VAV AT 12' -5" AFF— TO REMAIN EXISTIN6 16"0 1 EXISTIN6 LANDLORD DUCTWORK AT 15' -4" AFF TO REMAIN NEW 20x18 NEW IO "m 2 • • H C1} MECHANICAL PLAN NEW I8xI4 LI NEW 10 "m R ❑ d 215 ❑ e 0 NL R MECHANICAL EQUIPMENT SCHEDULE EXISTING FAN POWERED BOX MARK MANUFACTURER MODEL # GFM MIN. GFM SETTING MAX. GFM SETTING VOLT/ PHASE ACCESSORIES REF. NOTES FP -I TITUS ATS0 -1 2350 1800 2350 208/3 INTEGRAL 3 KW HEAT STRIP I. RELOCATE LL. COMPATIBLE CONTROLS WHERE INDICATED. - DIFFUSER CEILING DUCT DETAIL E `J SCALE: NOT TO SCALE PLAN MARK AIR DEVICE SCHEDULE (E.H. PRICE) MODEL # ASPD -3I FACE SIZE 24x24 24x24 24x12 NECK SIZE SEE PLAN TYPE S.G. 5.6. R.G. NOTES G/W SPF FRAME SEPARATE PERMIT REQUIRED FOR • Mechanical (a•Electrical • Plumbing as Piping c; ' of Tukwila '' a DIVISION NOTES BY SYMBOL O RELOCATE LANDLORD COMPATIBLE CONTROLS AT 48" AFF. VERIFY EXACT LOCATION PRIOR TO INSTALLATION. O EXISTIN6 EXHAUST FAN AND ALL ASSOCIATED DUCTWORK TO REMAIN. REPAIR OR REPLAGE TO LIKE NEW CONDITION TO ENSURE PROPER AND DEPENDABLE OPERATION. 0 CONTRACTOR SHALL FIELD VERIFY EXISTING VAV MEETS OR EXCEEDS THE MINIMUM REQUIREMENTS LISTED IN THE SCHEDULE ON THIS SHEET. REPAIR TO LIKE NEV CONDITION TO ENSURE PROPER AND DEPENDABLE OPERATION. PROVIDE ALTERNATE BID TO INSTALL NEW AS SPECIFIED IF NECESSARY. VAV NOTES I. USE ONLY LANDLORD SPECIFICATION VAV CONTROLS FOR THIS PROJECT. REFER TO TEMPERATURE CONTROL NOTES THIS SHEET FOR ADDITIONAL INFORMATION ON PROGRAMMING AND FINAL WIRING CONNECTIONS TO THE LANDLORD'S SYSTEM. 2. UTILIZE ONLY RIGID DUCTWORK UPSTREAM OF THE VAV BOX. PROVIDE FOUR EQUIVALENT DUCT DIAMETERS OF STRAIGHT DUCTWORK DIRECTLY UPSTREAM OF THE VAV BOX INLETS. 5. T.G.G. SHALL MAINTAIN ALL LL RETURN AIR OPENINGS IN DEMISING WALLS TO ENSURE OPERATION OF LL CENTRAL VAV SYSTEM. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. 1 M iovisicns will require a new plan submittal 11 and may include additional plan review fees. J t MECHANICAL NOTES I. FIRST TWENTY FEET OF SUPPLY/RETURN DUCTWORK FROM/TO UNIT SHALL BE INSULATED INTERNALLY WITH I -1/2" ACOUSTICAL LINER. DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR. 2. FLEX DUCT SHALL BE PREINSULATED WITH I-I/2" THICK FIBERGLASS, I# DENSITY FLEXMASTER OR EQUAL. PROVIDE SPIN -IN FITTING WITH INTEGRAL VOLUME DAMPER AT EACH TAP. MAXIMUM FLEX RUN - FIVE FEET (5' -09. 3. T.G.G. SHALL VERIFY EXACT LOCATION OF HVAG EQUIPMENT BEFORE FABRICATING DUCTWORK. 4. UPON COMPLETION OF CONSTRUCTION T.G.G. SHALL GLEAN COILS, ADJUST BELTS, REFRIG. CHARGE AND REPLACE FILTER MEDIA TO OBTAIN MAXIMUM EFFICIENCY. 5. T.6.0. SHALL PAINT ALL DIFFUSERS AND GRILLES TO MATCH ADJACENT CEILING OR AS SPECIFIED IN ARCHITECTURAL DRAWINGS. 6. PROVIDE BALANCING DAMPER AT DIFFUSER INHERE ACCESS 15 LIMITED. 'l. EXISTING DUCTWORK TO REMAIN AND BE REUSED WHERE POSSIBLE. 8. HVAC WORK TO CGtfOR'1 TO ALL APPLICABLE STATE, LOCAL AND REGULATORY AGENCY CODE REQUIREMENTS. T.G.C. SHALL USE LANDLORD APPROVED AIR BALANCING CONTRACTOR S. PROVIDE NEW DUCTWORK AS REQUIRED. T.6.G. SHALL GAP AND SEAL ALL UNUSED PORTIONS OF DUCTWORK AIRTIGHT. ANY NEW DUCTWORK SHALL. BE FABRICATED FROM GALVANIZED SHEET METAL OR STAINLESS STEEL. FIBERGLASS DUCTWORK WILL NOT BE PERMITTED. NO PVC PIPING ALLOWED. 10. ALL ABANDONED HVAC EQUIPMENT SHALL BE REMOVED COMPLETELY FROM SPACES AND ROOF BACK TO POINT OF ORIGIN. II. ALL ROOF WORK 15 TO BE PERFORMED BY LANDLORD DESIGNATED CONTRACTOR AT THE TENANTS EXPENSE. 12. T.G.G. SHALL DEMOLISH AND REMOVE ANY EXISTING DUCTWORK AND DIFFUSERS NOT BEING REUSED. 13. REBALANCE THE SYSTEM WITH NEW GFM'S SHOWN. Permit No :2;':QJ3 Plan raw approval is subject to ems and omissions" t, ;'1 +:ia I of construction documents does not authorize \, O a#iorl of any adopted code or ordinance. Receipt � : CRY : : acknowledged: oil approved F' i.. :4 .If s'• �� • / //' By Date: (Ai 14 I7ol- City ofhtkvwita BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1A 2012 City of Tukwila BUILDING DIVISION crtnetilemiA MAY 0 41011 PERMIT CENTER M12 013 R: \ALDO \J,tch \2012.Pro Jects \12. 3243. SouthcenterMaI(.Settle. WA \12.3243.M1.dwg ALDO DATE EMIS /ISSUED MAY 01, 2012 ALDO / SAJO / L.L., BID 4 PERMIT PRINT DATE • 2012-05-01 NO.I DATE I REVISION THIS DRAWING HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF NE ALDO GROUP AND ITS ASSOCIATED COMPANIES TO EXPLAIN THE LAYOUT AND SERVICES REQUIREMENTS FOR THE TRADE FIXTURES OR TO EXPLAIN COMPANY CONS1RUC1ION STANDARDS. ALL DIMENSIONS SHALL BE VERIFIED ON SITE. ALL ERRORS AND DISCREPANCIES SHALL BE REPORTED TO 1HE OWNER BEFORE PROCEEDING WITH THE WORK. NO DIMENSIONS SHOULD BE MEASURED ON THE DRAWING. DIMENSIONS AND AREAS ON THIS DRAWING ARE FOR INFORMATION ONLY d p c e 635 Westport Parkway Suite 300 Grapevine, Texas 76051 Phone: 817 -410 -2858 Fax: 817-251-8411 don penn • consulting engineer ALDO G R O U P E 2300 EMILE - BELANGER, MONTREAL QUEBEC, CANADA, H4R 3J4 TEL.: (514) 747 -2536 FAX: 1514) 747 -6504 PROJET /PROJECT: ALDO SOUTHGENTER lNESTW I ELD SEATTLE, V ASHINGTON TITRE /TITLE: MECHANICAL PLAN PROJET NO. /PROJECT NO. 2167 DESSINE /DRAWN: DA/JG ECHELLE /SCALE: VERIFIE /CHECKED: CONCEPT, ANNEE /YEAR: AAO6 PAGE: •-I EXISTING LANDLORD DUCTWORK AT 131-1" AFF TO REMAIN • EXISTING VAV AT 121-3" AFF TO REMAIN. REFER TO 11 • 11 • I . 0 II_ _I 1 LCtl _ _ EXISTING LANDLORD DUCTWORK AT 131-4" AFF TO REMAIN LI* •0" H El ,.‘ ........ ......... ......... „ . ................. MECHANICAL DEMOLITION PLAN SCALE: 1/4" = D El D SW a El El e -MO : ; 1 i ? ? Ll 4 / )/.1.3 1 '44. Li , w 14.-' ..1.- . ® a ° El NL El —Ne- LI it4 ;II 6 DEMO NOTES L EXISTING DUCTWORK AND DIFFUSERS TO BE REMOVED AS NOTED. 2. REMOVE ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PLUMBING FIXTURES AND PIPING SYSTEMS ETC. NOT BEING REUSED. DO NOT JUST A5ANDON. NOTES BY SYMBOL 0 EXISTING GRILLES AND ASSOCIATED BRANCH DUCT INDICATED ARE TO BE DEMOLISHED 0 MECHANICAL CONTRACTOR TO UTILIZE AS MUCH EXISTING DUCTWORK AS POSSIBLE IF IT MEETS SIZES SHOWN ON M-I REGARDLESS OF WHAT 15 SHOWN TO BE DEMOLISHED ON THIS PLAN. VERIFY IN FIELD ACTUAL EXISTING SIZES . REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1 A 2012 City of Tukwila BUILDING DIVISION CiTYRWatfiLA MAY 0 4 2012 PERMIT CENTER R: \ALDO \_Fitch \2012.Projects\12.3243.SouthcenterMall.Settle.WA \12.3243.M1A.dwg ALDO DATE EMIS/ISSUED MAY 01, 2012 ALDO / SAJO / L.L., BID 4 PERMIT PRINT DATE: 2012 05 01 NO. I DATE I REVISION IRIS DRAWING HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ALDO GROUP AND ITS ASSOCIATED COMPANIES TO EXPLAIN 1HE LAYOUT AND SERVICES REQUIREMENTS FOR THE 1RADE FIXTURES OR TO EXPLAIN COMPANY CONSTRUCTION STANDARDS. ALL DIMENSIONS SHALL BE VERIFIED ON SITE ALL ERRORS AND DISCREPANCIES SHALL BE REPOR1ED TO 1HE OWNER BEFORE PROCEEDING WITH THE WORK. NO DIMENSIONS SHOULD BE MEASURED ON THE DRAWING. DIMENSIONS AND AREAS ON THIS DRAWING ARE FOR INFORMATION ONLY d p c e don penn • consulting engineer 635 Westport Parkway Suite 300 Grapevine, Texas 76051 Phone: 817-410-2858 Fax: 817-251-8411 ALDO G R OUP E 2300 EMILE-BELANGER, MONTREAL QUEBEC, CANADA, H4R 3J4 TEL.: (514) 747-2536 FAX: 15141 747-6504 PROJET/PROJECT: ALDO SOUTHGENTER INESTFIELO SEATTLE, INASHINGTON TITRE/TITLE: MECHANICAL. DEMOLITION PLAN PROJET NO./PROJECT NO. 2167 DESS1NE/DRAWN: DAAJG ECHELLE/SCALE: .30.10•116 VERIF1E/CHECKED: BH CONCEPT, ANNEE/YEAR: AA0b PAGE: MECHANICAL SPECIFICATIONS 15100 GENERAL PRESCRIPTIONS 1.0 GENERAL NOTES 1.1 THE COMPLETE INSTALLATION SHALL BE MADE 114 STRICT ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS. CONSULT LANDLORD'S DESIGN CRITERIA. 1.2 THE DRAWINGS AND THE SPECIFICATIONS SHALL BE CONSIDERED ADDITIONAL TO ARCHITECT AND ELECTRICAL ENGINEER'S SPECIFICATIONS. ANY DISCREPANCY OR CONTRADICTION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. 1.3 ARCHITECT'S GENERAL REQUIREMENTS ARE PART OF THIS CONTRACT AND THEY SHALL BE APPLIED BY THE GENERAL CONTRACTOR AND SUBCONTRACTORS (HVAG- PLUMBING -FIRE PROTECTION ETC...). L4 GENERAL CONTRACTOR SHALL VISIT THE JOB SITE IN ORDER TO FAMILIARIZE HIMSELF WITH CONDITIONS THAT CAN AFFECT HIS WORK IN ANY MANNER. (MEASUREMENTS PARTICULAR CONDITIONS, ETC..) NO EXTRA COST DUE TO THE IGNORANCE OF LOCAL CONDITIONS WILL BE ACCEPTED BY THE OWNER 1.5 DUCTWORK, PIPING, EQUIPMENT AND ACCESSORIES ARE SHOWN SCHEMATICALLY. NO DIMENSION SHALL BE SCALED ON THE DRAWINGS. GIVE PRIORITY TO THE DIMENSIONS MARKED ON THE DRAWINGS. 1.6 GENERAL CONTRACTOR SHALL MAKE ALL NECESSARY CHECKING AND ADJJSTMENTS TO COMPLY WITH THE INTENT OF SPECIFICATIONS. 1.1 THE DRAWINGS SHOW THE APPROXIMATE LOCATION OF THE EQUIPMENT. EACH SUBCONTRACTOR SHALL VERIFY THESE LOCATIONS BEFORE INSTALLATION. L8 BEFORE STARTING THE WORK, COORDINATE ALL SUBCONTRACTOR WORK. NO EXTRA COST WILL BE ACCEPTED FOR A LACK OF COORDINATION. I.q GENERAL CONTRACTOR'S TENDER SHALL INCLUDE THE COST OF ALL NECESSARY PERMITS AND CERTIFICATES, ALL DRAWINGS APPROVAL COSTS AND ALL INSPECTION COSTS REQUIRED BY ALL AUTHORITIES HAVING, JURISDICTION. 1.10 EACH SUBCONTRACTOR SHALL COMPLETE THE WORK IN EVERY DETAIL. EVEN THOUGH NOT SHOWN ON DRAWINGS OR GALLED FOR IN THIS SPECIFICATION. 1.11 ALL RUBBISH'S AND GARBAGE SHALL BE REMOVED FROM THE JOB SITE AT THE END OF EVERY WORKDAY. AT THE CONTRACT COMPLETION, ALL TOOLS AND EQUIPMENT SHALL BE REMOVED AND THE JOB SITE SHALL BE LEFT IN A GLEAN CONDITION.. 1.12 STARTUP SHALL BE DONE BY MECHANICAL SUBCONTRACTOR AND THE GENERAL CONTRACTOR 1.13 COMPLY WITH ALL APPLICABLE CODES. 1.14 ALL. WORK AFFECTING, OTHER TENANTS SHALL BE DONE OFF BUSINESS HOURS (NIGHT OR WEEKEND). COORDINATE WITH THE LANDLORD. 2.0 GUARANTEE 21. EACH SUBCONTRACTOR SHALL GUARANTEE HIS. WORK FOR ONE YEAR AFTER DATE OF PROVISIONAL ACCEPTANCE BY THE TENANT. EACH SUBCONTRACTOR SHALL REPAIR OR REPLACE AT HIS OWN EXPENSE, ALL DEFECTS SHOWING DURING GUARANTEE PERIOD, AND THIS, WITHIN 48 HOURS FROM NOTICE. 2.2 PROJECTS IMPLYING AIR GONDITIONIN6 COMPRESSORS SHALL INCLUDE AN EXTENDED FOUR (4) YEARS WARRANTY PERIOD COVERING COMPRESSORS. 3.0 SHOP DRAWINGS AND INSTRUCTION MANUALS. 3.1 PRIOR TO ORDERING OR INSTALLING ANY EQUIPMENT, SUBMIT TO ENGINEER FOR APPROVAL A MINIMUM OF TO (2) COPIES OF SHOP DRAWINGS FOR EACH ITEM OF EQUIPMENT, IF REQUESTED. 3.2 UPON COMPLETION OF CONTRACT, SUBCONTRACTOR SHALL SUPPLY INSTRUCTION MANUALS, COVERING OPERATION AND MAINTENANCE OF EQUIPMENT INCLUDED IN HIS CONTRACT. INSTRUCTION MANUALS SHALL BE SUPPLIED • IN LOOSE LEAF BINDER, IN THREE (3) COPIES. • (ONE (I) COPY FOR THE LANDLORD AND TWO (2) FOR THE TENANT). INSTRUCTION MANUALS SHALL INCLUDE: a. ALL GUARANTEES ON EQUIPMENT AND INSTALLATIONS. b. TESTS RESULTS AND AIR BALANCE REPORT. c. OPERATION AND MAINTENANCE MANUALS. d. SPRINKLERS ACCEPTANCE CERTIFICATE AS PER NFPA -I3. 4.0 ALTERNATE EQUIPMENT 4.1 PROPOSAL SHALL BE BASED ON SPECIFIED EQUIPMENT AND MATERIAL. 4.2 PROPOSAL FOR ALTERNATE TO SPECIFICATION SHALL INCLUDE MANUFACTURER NAME, MODEL AND COST MODIFICATION. 4.3 COST OF ANY CHANGE REQUIRED TO OTHER TRADES WORK DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT, SHALL BE INCLUDED IN THE SUBCONTRACTORS PROPOSAL GALLING FOR THIS SUBSTITUTION. EVEN IF THESE CHANGES APPEAR AFTER THE DEMAND FOR SUBSTITUTION. 4.4 ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE CONTRACTS ARE AWARDED. NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT 15 SIGNED. 5.0 DRILLING AND ACCESS DOORS 5.I OBTAIN AUTHORIZATION FROM BUILDING, LANDLORD BEFORE DRILLING ANY HOLE IN CEILINGS, SLABS, OUTSIDE WALLS, TENANTS WALLS OR FIRE RETARDING WALLS. 5.2 OPENINGS, PAINTING, GUTTING AND PATCHING OF HOLES IN WALLS AND SLABS, SHALL BE MADE BY THE GENERAL CONTRACTOR. 5.3 ALL RECESSED FRAMES AND ACCESS DOORS, FIRE RETARDING ACCESS DOORS IN WALLS AND CEILINGS, SHALL BE SUPPLIED BY THE CONCERNED • SUBCONTRACTOR AND INSTALLED BY THE GENERAL. CONTRACTOR. THEY SHALL BE INSTALLED WHERE REQUIRED. THE SUBCONTRACTOR SHALL DETERMINE THE LOCATION IN ACCORDANCE WITH THE ARCHITECT. 6.0 DEMOLITION 6.1 EVERY SUBCONTRACTOR OF EACH SECTION SHALL EXECUTE DEMOLITION WORK DESCRIBE ON DRAWINGS, AND THOSE NEEDED TO COMPLETE CONTRACT ADEQUATELY. 6.2 UNLESS OTHERWISE INDICATED, ALL REMOVED AND UNUSED MECHANICAL EQUIPMENT SHALL BE TURNED TO THE LANDLORD. 15400 - FIRE PROTECTION 1.0 WORK INCLUDES GENERALLY, LABOR, SUPPLY AND INSTALLATION OF ALL MATERIALS AND EQUIPMENT REQUIRED FOR THE FIRE PROTECTION WORK INDICATED IN DRAWINGS AND SPECIFICATIONS. 2.0 THE TENANT'S FIRE PROTECTION SUBCONTRACTOR SHALL VISIT THE SITE IN ORDER TO WHITENESS ALL EXISTING CONDITIONS AND SUBMIT A DETAILED REPORT TO THE TENANT, DESCRIBING ALL DEFECTS IN EXISTING INSTALLATION. 3D INSTALLATION SHALL CONFORM TO ALL STANDARDS AND REGULATIONS REGARDING THIS TYPE OF CONTRACT TYPE, AND SHALL BE APPROVED BY THE AUTHORITIES HAVING JURISDICTION. TO BE COORDINATED BY THE BUILDING LANDLORD AS PER NFPA 15, LAST EDITION. 4A CONTRACTOR SHALL BE LICENSED FOR EXECUTION OF THIS TYPE OF WORK. 5.0 ALL MATERIALS SHALL BE FM, ULNLG LISTED, AND MEET ALL REGENT PUBLISHED REGULATIONS. 6.0 FIRE PROTECTION SUBCONTRACTOR SHALL MAKE SURE THAT INSPECTION OF 1415 INSTALLATION 15 MADE, BEFORE IT 15 CONGEALED BY GEILIN6 AND COVERING. 1.0 AT FINAL INSPECTION BY THE AUTHORITIES HAVING JURISDICTION, THE FIRE PROTECTION SUBCONTRACTOR SHALL MAKE ALL REQUIRED CHANGES, NECESSARY TO OBTAIN FINAL APPROVAL. 8.0 THE FIRE PROTECTION SUBCONTRACTOR SHALL OBTAIN A CERTIFICATE OF INSPECTION FROM AUTHORITIES HAVING JURISDICTION, AND TURN IT TO THE LANDLORD BEFORE FINAL APPROVAL. q.0 AUTHORITIES HAVING JURISDICTION, SHALL APPROVE DESIGN DRAWINGS, COMPLETE INSTALLATION, EQUIPMENT AND MATERIALS, INSPECT THEM AND SUPERVISE TESTS. (FIRE PROTECTION SUBCONTRACTOR SHALL PAY ALL COSTS AND FEE5). 10.0 PREPARE ALL INSTALLATION DRAWING'S, DETAILS AND HYDRAULIC CALCULATIONS NECESSARY TO OBTAIN APPROVAL FROM CONCERNED AUTHORITIES, BEFORE WORK 15 STARTED. (FIRE PROTECTION SUBCONTRACTOR TO PAY FOR ALL FEES AND COSTS INVOLVED). DIVISION 15000 15400 - FIRE PROTECTION (CONTINUED) 11.0 DRAWINGS SHALL INDICATE IN CLEAR MANNER: a. LOCATION OF THE BUILDING b. ADDRESS OR ANY OTHER: MEANS FOR DESIGNATION OF THE BUILDING a. HAZARD ZONE SCHEDULE d. FIRE PROTECTION SUBCONTRACTOR'S NAME AND ADDRESS a. AUTHORITIES HAVING JURISDICTION NAME f. THE SYSTEM DESIGN CRITERIA'S SUCH AS HAZARD TYPE, MINIMUM FLOW RATE AND THROW OF EACH SPRINKLER HEAD g. TOTAL REQUIRED WATER FLAW, INCLUDING INSIDE FIRE HOSE CABINETS, AND OUTSIDE FIRE HYDRANTS h. WATER SUPPLY " INFORMATION I. SUPPLY ONE (I) SEPIA AND TWO (2) COPIES, SCALE 1/4' = I'-O" (1 :50) OF INSTALLATION DRAWINGS. 12.0. THE ROOM 15 CLASSIFIED ORDINARY HAZARD. EACH SPRINKLER HEAD SHALL DOVER 130 sqft (12.Im ) MAXIMUM. TO BE COORDINATED WITH THE LANDLORD. 15.0 SEMI- LO6ARITHMIGS TYPE GRAPHICS SHALL INCLUDE WATER SUPPLY CURVES, SYSTEM REQUIREMENTS, EXTERIOR AND INTERIOR 1405E5 REQUIREMENTS, IN SUCH A WAY AS TO PRESENT A GRAPHIC RESUME OF HYDRAULIC CALCULATIONS., 14.0 PIPING AND FITTINGS SHALL BE APPROVED TYPE, IN COMPLIANCE WITH NFPA CODE, FM OR ULG IDENTIFIED AND DESIGNED TO WITHSTAND A WORKING PRESSURE OF 115 lb/actin (I2IOKPa).' 15.0 FIRE PROTECTION SUBCONTRACTOR SHALL INSTALL ALL VALVES SHOWN ON DRAWINGS AND AS NECESSARY FOR THE PROPER OPERATION OF THE INSTALLATION AND AS REQUESTED BY NFPA. 16.0 ELBOWS, REDUCERS, ADAPTERS, FITTINGS AND COUPLINGS SHALL BE SAME MANUFACTURE AS TEES. 11.0 PIPING SHALL BE BLACK STEEL, SCHEDULE 40, ASTM -A55, ASTM -A155 AND ASTM- A158. THREADED JOINTS, CAST IRON FITTINGS ASTM-AI26, 125 Ib /sgin (860KPa) BY GRINNELL, UL APPROVED, THREADED, HYDROSTATIC WORKING PRESSURE OF 115 Ib /sgln (I2IOKPa) AT 150'F (66 G) AND LESS. FLANGES PACKING, TUBE RUBBER, ALBION 350, I/8" (52mm). 18.0 RUNS OF PIPE AND EQUIPMENT LOCATION ARE SHOWN APPROXIMATE. FIRE PROTECTION SUBCONTRACTOR SHALL COORDINATE HIS INSTALLATION WITH THE CEILING, DUCTS, LIGHTING AND GENERAL LOOK OF THE WORK. 141.0 FLUSHING CONNECTIONS SHALL BE INSTALLED AT LOW POINTS WHERE REQUIRED AND WHERE INDICATED ON DRAWINGS, IN SUCH A WAY AS TO EMPTY THE SYSTEM COMPLETELY. 20.0 ALL SPRINKLERS SHALL BE OF AN APPROVED F06 TYPE WITH FUSE MELTING AT A VARIOUS TEMPERATURES ACCORDING TO THE REQUIREMENTS. 21.0 PENDANT SPRINKLER' HEAD: MICROMATIG, MODEL WITH GLASS FUSE (E -I), SEMI - RECESSED, CHROMED PLATED ESCUTCHEON AND SPRINKLER, OR ALTERNATE APPROVED EQUIPMENT. 22.0 UPRIGHT SPRINKLER HEAD; MICROMATIG, MODEL WITH GLASS FUSE (M), BRONZE FINISH. OR ALTERNATE APPROVED EQUIPMENT. 23.0 INVISIBLE SPRINKLER HEAD: STAR, MODEL H ( "UNSPOILER'), FULLY RECESSED IN GEILIN6 AND HIDE WITH 4" DIAMETER PLATE OR ALTERNATE' APPROVED EQUIPMENT. 24.0 REMOVED SPRINKLER HEADS SHALL NOT BE REUSED. 25.0 FIRE PROTECTION SUBCONTRACTOR SHALL INSTALL SPRINKLER GUARDS IN LOCATION WHERE SPRINKLERS MAY BE SUBJECT TO MECHANICAL IMPACTS AND WHERE INDICATED ON DRAWINGS. 26.0 FIRE PROTECTION SUBCONTRACTOR SHALL INSTALL EVERYWHERE PIPES RUN THROUGH WALLS, FLOORS, CEILINGS ETC... A CAST IRON ESCUTCHEON ON EACH SIDE OF THE PARTITION. FI6915 OF GRINNELL OR ALTERNATE APPROVED EQUIPMENT. 21.0 FIRE PROTECTION SUBCONTRACTOR SHALL INSTALL EVERYWHERE PIPES RUN THROUGH ACOUSTICAL CEILINGS, CHROMED STEEL ESCUTCHEON WITH CLAMPING MECHANISM, AND CONGEALED HINGES, FI620 OF GRINNELL, OR ALTERNATE APPROVED EQUIPMENT. 28.0 FIRE PROTECTION: SUBCONTRACTOR SHALL COORDINATE WITH LANDLORD'S UNDERWRITERS THE ADDITION OF SPRINKLER HEADS OVER FINISHED CEILING. 2W FIRE PROTECTION SUBCONTRACTOR SHALL SUPPLY AND INSTALL TWO (2) PORTABLE FIRE EXTINGUISHERS, ABC PRY POWDER, PRESSURE TYPE, GLASS 6A, SOBG,10 POUNDS (45 K6) CAPACITY, 235 Ib /sgin (1620 KPa) WORKING PRESSURE. MODEL WBDL ABGIO OF GFH, WALL INSTALLATION, OR ALTERNATE APPROVED EQUIPMENT. 15500 VENTILATION- HEATING -AIR CONDITIONING 1.0 WORK INCLUDES GENERALLY, LABOR, SUPPLY AND INSTALLATION OF ALL MATERIALS AND EQUIPMENT REQUIRED FOR THE VENTILATION WORK INDICATED IN DRAWINGS AND SPECIFICATIONS. 2.0 THE TENANT'S VENTILATION SUBCONTRACTOR SHALL VISIT THE SITE IN ORDER TO WHITENESS ALL EXISTING CONDITIONS AND SUBMIT A DETAILED REPORT TO THE TENANT, DESCRIBING ALL DEFECTS IN EXISTING INSTALLATION. 3.0 THE LANDLORD'S VENTILATION SUBCONTRACTOR SHALL VERIFY ALL HVAG UNITS AND THE TENANT'S VENTILATION SUBCONTRACTOR SHALL PERFORM THE NECESSARY CORRECTIONS WITHOUT BEING LIMITED TO: a BALL BEARINGS LUBRICATION. b. COILS, CLEANING, AND PURGING. G. FANS: REPLACE BELTS, ALIGNMENT IF REQUIRED. d. REPLACE FILTER MEDIA. a. CHECK REFRIGERANT CHARGE. f. CHECK WIRING AND CONTROLS. g. CONDENSER AND ACCESSORIES CLEANING. h. PERFORM BALANCING WORK AND SUPPLY A BALANCING REPORT TO OWNER AND TENANT. 4.0 THE VENTILATION SUBCONTRACTOR SHALL ADJUST THE AIR QUANTITIES OF UNITS AS PER DRAWINGS AND SPECIFICATIONS. 5.0 THE VENTILATION SUBCONTRACTOR SHALL VISIT THE JOB SITE TO MAKE SURE OF THE EXACT LOCATION OF NEW DUCTS, GRILLES AND DIFFUSERS. HE SHALL ALSO SUPPLY SHOP DRAWINGS TO THE TENANT BEFORE FABRICATION AND INSTALLATION. 6.0 THE EXACT LOCATION OF GRILLES AND DIFFUSERS SHALL BE MADE IN ACCORDANCE WITH THE LAST ISSUED REFLECTED CEILING PLAN. TO BE COORDINATE WITH ARCHITECT. 7.0 WHEN REQUIRED, SMOKE DETECTORS SHALL BE SUPPLIED AND INSTALLED BY VENTILATION SUBCONTRACTOR. 8.0 THE VENTILATION SUBCONTRACTOR SHALL VERIFY AND REPAIR THE EXISTING DUCTS INDICATED ON DRAWINGS. INCLUDING ACOUSTICAL AND THERMAL INSULATION. 01.0 NEW DUCTS SHALL BE MADE OF GALVANIZED STEEL SHEET. CONNECTIONS AND INSTALLATION INCLUDING JOINTS AND ANCHOR GAGES AS PER ASHRAE/SMAGNA REQUIREMENTS. DIMENSIONS INDICATED ON DRAWINGS ARE INTERNAL DIMENSIONS. 10.0 MANUFACTURED FLEXIBLE DUCTS FROM "SIMPLEFLEX" OF A MAXIMUM OF FIVE (5) FEET (I50Omm) IN LENGTH, TO BE INSTALLED AT THE INLET OF AIR TERMINAL UNITS, DIFFUSERS, ETC. 11.0 THE TENANT SHALL INDICATE TO THE VENTILATION SUBCONTRACTOR, THE EXACT NEW LOCATION OF THE EXISTING THERMOSTAT: ALL CONTROLS COMPONENTS SHALL BE VERIFIED. 12.0 WHEN REQUIRED, INSTALL FIRE DAMPERS WHERE INDICATED ON DRAWINGS. FIRE DAMPERS IN ACCORDANCE WITH NFPA- gOA.GIOB STANDARDS. ULG LISTED. a. RECTANGULAR DUCTS: RECTANGULAR COLLAR , TYPE '5' WITH NO AIR STREAM INTERFERENCE. IN SPECIAL CASES WHERE VERTICAL SPADE IS LIMITED TYPE 'A' MAY BE ACCEPTABLE. b. ROUND DUCTS : CIRCULAR COLLAR, GR TYPE WITH NO AIR STREAM INTERFERENCE. 13.0 SUPPLY AND INSTALL MANUAL DAMPERS WHERE INDICATED ON DRAWINGS. SINGLE OR MULTIPLE BLADE DAMPERS, OPPOSED BLADE TYPE, MANUALLY ADJUSTABLE FOR AIR FLOW ADJUSTMENT. 15700 - ACOUSTICAL AND THERMAL INSULATION 1.0 GENERAL NOTES 1.1 WORK INCLUDES GENERALLY, LABOR, SUPPLY AND INSTALLATION OF ALL MATERIALS AND EQUIPMENT REQUIRED FOR THE INSULATION WORK INDICATED IN DRAWINGS AND SPECIFICATIONS. 1.1 WORK INCLUDES GENERALLY, LABOR, SUPPLY AND INSTALLATION OF ALL MATERIALS AND EQUIPMENT REQUIRED FOR THE INSULATION WORK INDICATED IN DRAWINGS AND SPECIFICATIONS. 2.0 PLUMBING 2.1 INSTALL I (25.4.mm) THERMAL INSULATION ON DOMESTIC WATER PIPING UP TO PLUMBING FIXTURES. RESIN IMPREGNATED GLASS FIBER. 2.2 MOLDED FIBERGLASS BONDED WITH BAKED RESIN, WITH ALUMINUM COVERING AND OUTSIDE WHITE FINISH. . MAXIMUM THERMAL CONDUCTIVITY OF 0.24 131U- in/h -ft 2 - F (0.03511/m G) AT 1527 (24 t). JOINTS SHALL BE COVERED WITH STRIPS OF ALUMINUM FOIL, SEAL. WITH VAPOR PROOF ADHESIVE. 3.0 VENTILATION 5.1 INSTALL ACOUSTICAL INSULATION WHERE REQUESTED IN THE SPECIFICATION. FLEXIBLE INSULATION CONFORM WITH NFPA q0, 2 Ib/ft° (32 KG /m °) OF DENSITY FOR 1/2" (I3mm) THICKNESS AND 1.5 Ib /ft° (24.03 KG /m ) FOR OTHER THICKNESS. COVER SIDE EXPOSED TO AIR STREAM WITH BLACK CANVAS. 32. INSTALL ACOUSTICAL INSULATION ON HVAG UNITS SUPPLY DUCT FOR TEN (10) FEET (3m) IN LENGTH. 5.3 INSTALL ACOUSTICAL INSULATION ON HVAG UNITS RETURN DUCT FOR TEN (10) FEET (3m) IN LENGTH FROM UNITS. 3.4 INSTALL THERMAL INSULATION WHERE REQUESTED IN THE SPECIFICATION. RIGID FIBERGLASS BLANKET OF 5Ib/ft° (48K6 /m°) OF DENSITY, MAXIMUM CONDUCTIVITY OF 0.25 5T1J- In/h- ft' -7 (0.033W/m'G) AT 15.2°F (24 G) WITH TYPE RFFRK VAPOR BARRIER. 5.5 INSTALL THERMAL INSULATION ON ALL TOILET EXHAUST AIR DUCTS WHEN CONNECTED TO AIR EXHAUSTS. COOL.LNG OA DB COOLING LA DB + HEATING OA. + ROOF U.-FACTOR + LIGHT DIVERS " VAV' MIN AIR + LTk- SURFACE + %LIS- SURFACE a WALL AREA + %ROOF TO SPACE PEOPLE: SENS MEAT ALDO South center Mail Seatt le, WA 2350 SQUARE FEET ASHRAE DESIGN CONDITIONS 21T 2: CtOLIt� COOLING OA WB COOLING IA WB` HEATING IA 7 LTS- RECESSED ;ISM %LTS- RECESSED 7 - MISC. WATTS 000 SQ FT/PERSON NO OF PEOPLE WALL U- FACTOR O:2C PEOPLE LATENT 20G OA St MMf1,RY SENSIBLE ': HE, ,TG.,+;.IN LATENT HEAT GAIN PEOPLE VENTU.AT1ON ROOF LOAD LTA:-SURFACE LTS- RECESSEQ MISC LOAD WALL LOAD 7 PEOPLE. 0 VENTILATION. (I' ` 70% TO SPACE 11644 1QI % TO SPACE 1565 70% TO SPACE 10239 0 TOTAL SEN SJ ILE X15375 TOTA L. 6267 TENT 6267 3.5 WJSQ FT TOTAL CO« LUNG LOAD 5'1 .2 BTiJH 0.98 CFM /SQ FT SENS/TOTAL RATIO E18 % 22 BTtJH /SCE FT NOMINAL CFM (15 DEG F OF 22 I CFM 4.; TONS + SUPPLY AIR TEMP DEG F TEMPERATURE DIFFERENCE 13 DEG F SENSIBLE HE, T GAIL VIENT.ATIONL ROOF LOAD WALL LOAD TOTAL SENSIBLE IEA.TINC LOAD St.1! 0 0 0: ARV LATENT HEAT GAIN VENTILATION TOTAL LATENT TOTAL HEATING LOAD I#1OMNAL II/ OLEO HEAT MINNUM KW ELEC -TEAT (BASED ON 20 DEG F RISE VAV MIN AIR) 0 BTUH. 0 KW 2 K - 546 SQ FT/TON LEGEND tit f Q2=3 e CFM ELBOW WITH TURNING VANES SUPPLY DUCT RETURN OR EXHAUST DUCT TAKE -OFF WITH BOOTH MANUEL DAMPER TRANSFORMATION FROM RECTANGULAR DUCT TO FLEXIBLE DUCT ELECTRICAL COIL THERMOSTAT VENTILATION GRILLE TYPE CUBIC FEET PER MINUTE CUBIC FEET PER MINUTE DUCT TO BE DEMOLISHED MPrP0'73 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1 R 2012 City of Tukwila BUILDING DIVISION CITY ` MAY 04.2012 PERMIT CENTER R: \ALDO \Jitch \ 2012. Projects \12. 3243. SouthcenterMall.Settle. WA \12.3243.M2.dwg ALDO DATE EMIS /ISSUED MAY 01, 2012 ALDO / SAJO / L.L., BID 4 PERMIT PRINT DATE • 2012 -05 -01 fy ,`,. J PD% - _ :, ,: fel NO.I DATE I REVISION THIS DRAWING HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ALDO GROUP AND ITS ASSOCIATED COMPANIES TO EXPLAIN THE LAYOUT AND SERVICES REQUIREMENTS FOR THE TRADE FIXTURES OR TO EXPLAIN COMPANY CONSTRUCTION STANDARDS. ALL DIMENSIONS SHALL BE VERIFIED ON SITE ALL ERRORS AND DISCREPANCIES SHALL BE REPORTED TO THE OWNER BEFORE PROCEEDING WITH THE WORK. NO DIMENSIONS SHOULD BE MEASURED ON THE DRAWING. DIMENSIONS AND AREAS ON THIS DRAWING ARE FOR INFORMATION ONLY d p c e 635 Westport Parkway Suite 300 Grapevine, Texas 76051 Phone: 817 - 410 -2858 Fax: 817- 251 -8411 don penn • consulting engineer ALDO GR O U P E 2300 EMILE - BELANGER, MONTREAL QUEBEC, CANADA, H4R 3J4 TEL.: (5141 747 -2536 FAX: (514) 747 -6504 PROJET /PROJECT: ALDO SOUTHGENTER !NESTW I ELD SEATTLE, 1NA5H I N&TON TITRE /TITLE: MECHANICAL SPECIFICATIONS PROJET NO. /PROJECT NO. 261 DESSINE /DRAWN: DA /J6 ECHELLE /SCALE: CONCEPT, ANNEE /YEAR: AAO6 VERIFIE /CHECKED: BH M -2 PAGE: