Loading...
HomeMy WebLinkAboutPermit M12-074 - INDUSTRIAL REVOLUTIONINDUSTRIAI. REVOLUTION 5835 SEGALE PARK DR C M12 -074 City Tukwila Departfnent of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 3523049018 Address: 5835 SEGALE PARK DR C TUKW Project Name: INDUSTRIAL REVOLUTION Permit Number: M12 -074 Issue Date: 05/23/2012 Permit Expires On: 11/19/2012 Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA WA 98138 Contact Person: Name: JOFFRE SECHIER Address: 3202 C ST NE , AUBURN WA 98002 Email: JOFFRE @COMFORTMECH.COM Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P -105 , KENT, WA 98032 Contractor License No: COMFOMI015LA Phone: 425 - 251 -9840 Phone: 425 - 251 -9840 Expiration Date: 06/01/2012 DESCRIPTION OF WORK: INSTALL (1) 4020 CFM EXHAUST FAN AND (1) INTAKE HOOD WITH DUCT TO WITHIN 12" FROM FLOOR Value of Mechanical: $3,750.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied amin ith, Fees Collected: $233.13 International Mechanical Code Edition: 2009 Date: Z d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not pres - - to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t periormance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this pe Signature: Print Name: Date: 'l '7a3 /('L )()IV_ -Q LHl.R This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12-074 Printed: 05 -23 -2012 • • PERMIT CONDITIONS Permit No. M12-074 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Structrual Observations in accordance with I.B.C. Section 1709 is required. At the conclusion of the work included in the permit, the structural observer shall submit to the Building Official a written statement that the site visits have been made and identify any reported deficiencies which, to the best of the structural observer's knowledge, have not been resolved. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ** *FIRE DEPARTMENT CONDITIONS * ** 8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 9: A manual shutoff control shall be provided outside of the room in a position adjacent to the access door to the room or in an approved location. The switch shall be a break -glass or other approved type and shall be labeled; VENTILATION SYSTEM EMERGENCY SHUTOFF. (IFC 2704.3.1 -4). 10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 11: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 12: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M12 -074 Printed: 05 -23 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd , Suite 100 Tukwila. 11'.4 98188 http://www.TukwilaWA.e,ov Mechanical Permit No. Project No, Date Application Accepted: 0 Date Application Expires: �.k — (For office use anti)' MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** King Co Assessor's Tax No.: 3523049115 Site Address: 5835 Segale Park Drive C Suite Number: Floor: New Tenant: m Yes ❑..No Tenant Name: Industrial Revolution PROPERTY OWNER Name: Joffre Sechier Name: Segale Properties City: Auburn State: WA Zip: 98002 Address: 5811 Segale Park Drive C Email: joffre@comfortmech.com City: Tukwila State: WA Zip: 98188 CONTACT PERSON - person receiving all pmject • `._ • communication Name: Joffre Sechier Address: 3202 C Street NE City: Auburn State: WA Zip: 98002 Phone: (425) 251 -9840 Fax: (253) 736 -6598 Email: joffre@comfortmech.com MECHANICAL CONTRACTOR INFORMATION - Company Name: Comfort Mechanical Address: 3202 C Street NE City: Auburn State: WA Zip: 98002 Phone: (425) 251 -9840 Fax: (253) 736 -6598 Contr Reg No.: COMFOM10I5LA Exp Date: 06/01/2012 Tukwila Business License No.: BUS - 0993365 Valuation of project (contractor's bid price): $ 3,750 Describe the scope of work in detail: cILL (-0 4 IS Q-N-r1 T-P.61 4K0 (0 A-KVA-Lc 60 Doz k6 Wrc N Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ 22)-` Fuel Type: Electric ❑ Gas ❑ Other: H: \Applications \Forms- Applications On Line\201 I Applications \Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type : Qty <IOOk btu Furnace >100k btu Floor furnace Suspended/wall /floor mounted heater Appliance vent 1 Repair or addition to heat/refrig /cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system 1 Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type " ,Qty" Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Name: AUTHORIZED AGENT: Sechier Mailing Address: 3202 C Street NE H: \Applications \Forms- Applications On Line \2011 Applications \Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Date: / / Day Telephone: (425) 251 -9840 Auburn WA 98002 City State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 3523049018 Permit Number: M12 -074 Address: 5835 SEGALE PARK DR C TUKW Status: PENDING Suite No: Applied Date: 05/11/2012 Applicant: INDUSTRIAL REVOLUTION Issue Date: Receipt No.: R12 -01555 Initials: User ID: Payee: WER 1655 Payment Amount: $233.13 Payment Date: 05/11/2012 10:50 AM Balance: $0.00 JOFFRE SECHIER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 21119G ACCOUNT ITEM LIST: Description 233.13 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 186.50 000.345.830 46.63 Total: $233.13 doc: Receiot -06 Printed: 05 -11 -2012 ''.INSPECTION RECORD Retain a copy with permit INSPE6TION -N ©^" _ PERMIT NO. CITY:OE.TUKWILA BUILDING DIVISION 6300 SouthcenterBlvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection: Request Line (206) 431 -2451 it17 -Olt Project: , fI Vt!/!K 1� "[� Type of Inspection: 11 ,, tt -nNk . Address: , EEll �^ Date Called: Special Instructions; Date Wanted:. , t p Vi m. C Requester: Phon No: �c 141'43— b2)11 t Approved per applicable. codes. Corrections required prior to approval. COMMENTS::. Date: REINSPECTION FEE REQUI ED. Prior t next inspection, fee must be paid at 6300 Southcenter.Blvd., Suite100, Call to schedule reinspection. ,► 1 ' INSPECTION RECORD Retain a copy with permit INSPECTION NO. r/2-, 07Y PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: v s -7z,n/. Pc' t./ Type of Inspection: ■ ih'r h- ikki W Address: f 35 se 646 P4e4- Date Called: t- R -. / , f ' i--7/047/ AWL) Pi) ,P1, Special Instructions: AooP 4�'ass 4/irll49 d 6./g.2-.6/ Date Wanted:. 7► - 2. D _. /�. a.m: P.m: Requester: /�, a r ir) ( , Phone No: .20 6 -- 96 -$ 5 6 Z Approved per applicable codes. ® Corrections required prior to approval. COMMENTS: ,t I % i d) /CJ �'! �� "V ` A6pt/C' Gt/��/• LIr 1 -. / , f ' i--7/047/ AWL) Pi) ,P1, specs r' n Date: -2—a El PECTION FEE REQUIRE . Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: .--".v. L \i j -c 1a!— ee vo LA t u te, Type of Inspection: rr ac'■ (--e �1 eN o.l...,, Address:3i35 S--3 Suite #: €. (..i• Person: Dec,.nv Tr Q5 Special Instructions: Phone No.: 425– 4 'k'3 — S3 t\ 154,Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: ' es Sprinklers: ES ?14,,, Fire Alarm: Nr■r\r›,v...)AL._ Hood & Duct: Monitor: �a11 ‘t,� -$or ‘ICto.rv., Pre -Fire: Permits: Occupancy Type:, Inspector: - 5 ( Date: S(311 (7 Hrs.: t $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 •i Date: 5/9/2012 FILE COPY AMERICAN oo a/re-"— FAN SUBMITTAL COVER SHEET To: COMFORT MECHANICAL ATTN: JOFFRE Address: Phone: Fax: Email: Project: SEGALE H -3 Location: TUKWILA Engineer: COMFORT MECHANICAL REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2012 City of Tukwila BUILDING DIVISION From: Air Tec Co By: Mike Snorsky Address: 85 South Orcas Phone: 206 - 763 -9911 Fax: 206 - 763 -1950 Email: msnorsky @airtecco.com Comments: M RECEIVED MAY 112012 PERMIT CENTER Page 2' of 6 SEGALE H -3 Fan Schedule Item Tag Qty Model Drive Flow SP CFM inWg Fan RPM Sones Power Motor BHP HP Voltage /Ph Type Accessories /Notes 1 EF -1 1 UBCA2OKD1231 Belt 4,020 0.125 846 11.7 0.566 3/4 115V/230V 1PH OPEN PFC1 A/D A/D UL762 IH -1 TIV24X24AL .4,020: 0.115 D% Accessory Key Abbreviation Description Abbreviation Description A/D AMCA B CONSTRUCTION A/D ROOF CURB A/D EXPLOSION PROOF MOTOR PFC1 Roof Curb Page 3' of 6 Model Information UBCA AMCA Licensed for Sound and Air Performance. Power rating (BHP) does not include transmission losses. Bearing losses are included. Performance ratings do not include the effects of appurtenances (accessories). Performance shown is for Installation Type 'A' : Free inlet, Free outlet. The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5 ft.) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type 'A' : Free inlet hemispherical sone levels. Sound ratings apply to sones only. • TAG: EF•1 Type UBCA Belt Drive Centrifugal Upblast Power Roof Ventilator INDUSTRIES AMERICAN COOLAIR CORPORATION Accessories A/D EXPLOSION PROOF MOTOR A/D AMCA B CONSTRUCTION PFC1 Roof Curb Weight: 350 lbs. Qty Model No. 1 UBCA2OKD1231 Sones 11.7 C B DIA. A Fan Data CFM inWg 4,020 0.125 LwA dba @5. 74 .t$Yet21.11 ran aoaTxa L.000+1t4o115 LIt lard lSWt 00, 62 American Coolau Corporation certifies that the Type UBCA units shown herein are licensed to bear the AMCA seal The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA certified Ratings Program. Notes: UL762 Project: SEGALE H -3 Location: TUKWILA dba @ 10' 56 1 25 1.00 0.75 a of 0.50 a 025 A SQ. I.D. B C D 43 3/8 I 29 7/8 i 251 /2 Tip Speed: 4,626 ft/min RPM BHP MHP 846 0.566 3/4 dba @ 20' 50 63 Hz , Dimensions in inches unless otherwise noted Motor Data RPM Voltage /Ph 1,750 115V/230V 1 PH 2" Page 4 of 6 • Non - overloading aluminum wheel computer balanced • Force ventilated motor compartment isolated from airstream • Variable pitch motor pulley • Adjustable hinged motor bracket with bolt belt tension adjustment • Weatherproof spun aluminum housing • NEMA Standard open drip - proof motors • Overlapping wheel /inlet venturi • Built -in grease and water removal drain • Heavy duty self - aligning pillow -block bearings with cast iron housing • AMCA label for air and sound • UL Listed for Standard 705 or Standard 762 (most models) Outlet Velocity: 1,151 ft/min Accessories Hz Encl. PFC1 A/D A/D 60 !OPEN; Octave Band Sound Power (LwA) 125 Hz 250 Hz 76 79 73 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 69 68 67 62 54 Air Density: 0.075 Ibs /ft^3 25 1 00 0.75 o x s 0.25 0.00 500 1,000 1,500 2,000 2.500 3,000 3,500 4,000 4.500 Volume Flow Rata (CFM) Engineer: COMFORT MECHANICAL AMCA Licensed for Sound and Air Performance Power rating (BHP) does not include transmission losses. Beanng losses are included. Performance ratings do not include the effects of appurtenances (accessories) Performance shown is for Installation Type 'A': Free inlet, Free outlet The sound ratings shown are loudness values in henosphencal sones at 1.5 m (5 h) m a hemispherical free field calculated per AMCA Standard 301. Values shawl are for Installation Type 'A' : Free inlet hemispherical sone levels Sound ratings apply to sones only. Contractor: COMFORT MECHANICAL Submitted By: Approved By: Date 5/9/2012 Date FanSelect 6 - January 2012 ver. 6.5.4 • Type TIV Trimline Fresh Air Intake Ventilator €;await: it& INDUSTRIES Accessories A/D ROOF CURB Weight: 72 lbs. TAG: IH -1 • All aluminum construction with standard mill finish • Miter cut and continuous welded curb base corners • Hood assembled with standing and snap back seams secured with spot welds Bird Screen Page 5 of 6 • Reinforced hood braced for extra strength • Hood perimeter opening is double the throat area for low intake velocities • 1/2" x 1/2" galvanized welded wire mesh bird screen • Wide hood overhang for storm protection — .050" Aluminum .080" Aluminum -.__— Throat Width E D 1— A B C 24 24 42 B Throat Length 2 F D E F 42 32 32 G 5 G 11 Dimensions in inches unless otherwise noted Flow Pressure Drop Throat Velocity Qty Model No. CFM inWg ft/min 1 TIV24X24AL 4,020 0.115 1,005 Notes: Project: SEGALE H -3 Engineer: COMFORT MECHANICAL Location: TUKWILA Contractor: COMFORT MECHANICAL Submitted By: Date 5/9/2012 Approved By: Date FanSelect 6 - January 2012 ver. 6.5.4 • Page 6of6 Type PFC1 and PFC2 Roof Curb Dimensions For Fan Models UBCA - UDCA - CUBA INDUSTRIES AMERICAN COOLAIR CORPORATION P.O. Box 2300 Jacksonville, Florida 32203 Phone: (904) 389-3646 Fax: (904)387- 3449•(904)381 -7560 E -mail: fans @coolair.com Internet: www.coolair.com t PFC1 - 8 PFC2 - 12 1 5/8 1 1 5/8 ■ D SQ. H O.D. J I.D. Optional — Damper Shelf G SQ.* Wood Nailer 11/2 Thick Insulation Unit Size Roof Curb and Damper Dimensions D G* H J 06, 08, 10 24 1/2 11 1/4 16 1/2 13 1/4 12, 13, 15 32 1/2 19 1/4 24 1/2 21 1/4 16, 18 36 1/2 23 1/4 28 1/2 25 1/4 20, 21, 24 40 1/2 27 1/4 32 1/2 29 1/4 30 461/2 331/4 381/2 351/4 36 52 1/2 29 1/4 44 1/2 41 1/4 44 62 1/2 49 1/4 54 1/2 51 1/4 * - The Damper Shelf is an optional accessory. Dimensions in inches •PEFiMIT COCA CUP', M PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -074 DATE: 05 -11 -12 PROJECT NAME: INDUSTRIAL REVOLUTION SITE ADDRESS: 5835 SEGALE PARK DR C X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Binding Dsio I Public Works ❑ /1114A 11414/ giV1)" Fire Prevention Structural Planning Division n n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05-15 -12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route X Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06-12 -12 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople ter Friendly Page General /Specialty Contractor A business registered as a construction contractor with Lli1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name COMFORT MECHANICAL UBI No. 601954041 INC Phone 4252519840 Status Active Address 3202 C St Ne License No. COMFOMI015LA Suite /Apt. License Type Construction Contractor City Auburn Effective Date 6/1/1999 State WA Expiration 4/25/2014 Date Zip 98002 Suspend Date County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FIVESM'010JT FIVE STAR MECHANICAL Construction Contractor General Unused 4/30/1999 5/1/2014 Active COMFOP'064D2 COMFORT PLUS Construction Contractor Air Conditioning Air Heat,Ventilation,Evaporat 3/22/1994 3/21/2000 Archived FIVESSE941KU FIVE STAR ENERGY SOLUTIONS Construction Contractor General Unused 5/24/20065/24/2008 06/01/2005 Expired Business Owner Information Name Role Effective Date Expiration Date JACKSON, SHIRLEY A President 01/01/1980 Amount JACKSON, HERB J Vice President 01/01/1980 9849307 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 COLONIAL AM CAS Et SURETY OF MD LPM4041162 06/01/2002 Until Cancelled $6,000.00 05/15/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 Federated Mutual Ins Co 9849307 06/01/2010 06/01/2013 $1,000,000.00 04/24/2012 7 FEDERATED MUTUAL INS CO 9849306 06/01/2006 06/01/2010 $1,000,000.0005/O1/2009 6 FEDERATED SERV /MUT INS CO 9849306 06/01/2005 06/01/2006 $1,000,000.0004 /25/2005 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni /bbip /Print.aspx 05/23/2012 PARCEL DATA Parcel Name Site Address Geo Area 352304 -9115 SEGALE PROPERTIES LLC 15811 SEGALE PARK - C DR 98188 70 -50 Spec Area Property Name 1500 -25 Legal Description DISTRIBUTION WAREHOUSE fi Jurisdiction I Levy Code Property Type ;Plat Block / Building Number 1 Plat Lot / Unit Number € Quarter- Section - Township -Range TUKWILA 2360 C SW -35 PAR E OF TUKWILA BLA #L02 -029 REC #2002100790001 SD PAR LOCATED E 1/2 SW 1/4 OF SD SEC ASSESSOR DATA. PROJECT DESCRIPTION: 1. INSTALL (1) 4,020CFM (1CFM /SF) ROOFTOP EXHAUST FAN TO PROVIDE FOR CONTINUOUS VENTILATION PER IFC 2704.3.1 2. PROVIDE AND INSTALL (1) ROOF HOOD WITH DUCTING DOWN TO WITHIN 12" OF FLOOR PER IFC 2704.3.1 Description SEPARATE REQUIRED FOR IT 0 Mechanical Electrical Plumbing Gas Pipit, City of Tukwila staNtici DIVISION Map of; Segale Properties 5811 Segale Park Drive C Tukwila, WA 98188 (206) 575 -2000 No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. j VICINITY MAP SUBJECT OF THIS PERMIT uu❑ uuuu'Lu NORTH OVERALL BUILDING PLAN EXISTING UJARENOUSE EF -1 PROPOSED 4-43 ROOM IH -1 6m'dd° 28" ROUND PIPE TO WITHIN 12" AFF H3 ROOM PLAN_ NORTH O Z �.. _._e_.*... .■4,4•11.... REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2012 City of ila BUILDING I ISION FILE COPY n Penult No., M -. 01 Plaaxeview approval Is subs to errors and =lost Appro gal of construction documents does not auttlori . the violation 'f any adopted code or ordinance. Rece of approv- e ` 1 *, and oondltions is adcnowledgE cue: iimitsty B z City Of'rukwiia BUILDING DIVISION RECEIVED MAY 112012 PERMIT CENTER. 6•17-C) 714 REVISIONS IIWAC SERVICE MID comonsucnou 6802 S. 220TH STREET KENT, WA 98032 425.251.9840 F. 425.251.9871 f MLGI I0I SUS 15 SI KWI DATE, SCALE: DRAWN: CHECKED: Ilt ir. M 1 00 -000 ■ J