Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M12-078 - BOEING #9-101
BOEING #9 -101 9725 EAST MARGINAL wys M12 -078 City o/Ofukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0003400018 Address: 9725 EAST MARGINAL WY S TUKW Project Name: BOEING #9 -101 Permit Number: M12 -078 Issue Date: 07/03/2012 Permit Expires On: 12/30/2012 Owner: Name: BOEING COMPANY THE Address: PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 98124 Contact Person: Name: TOM NAVRATIL Address: 2945 NE ARGYLE ST , PORTLAND OR 97211 Email: TOM.NAVRATIL @PERMCOLD.COM Contractor: Name: PERMACOLD ENGINEERING INC Address: 2945 NE ARGYLE ST , PORTLAND OR 97211 Contractor License No: PERMAEI077RO Phone: 971 404 -0586 Phone: 503- 249 -8190 Expiration Date: 12/08/2012 DESCRIPTION OF WORK: INSTALL (2) EVAPORATORS INTO A COOLING CHAMBER TO PIPE TO A CONDENSING UNIT LOCATED OUTSIDE THE BUILDING Value of Mechanical: 110,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Fees Collected: $1,412.06 International Mechanical Code Edition: 2009 Permit Center Authorized Signature: ALI ∎ i .L Date:7 C/ I hereby certify that I have read and examined this p t and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorize • o s • • n and obtain this mechanical permit and agree to the conditions on the back of this permit. j Signature: rC(IQ.. Date: Print Name: l (i trJ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -078 Printed: 07 -03 -2012 PERMIT CONDITIONS Permit No. M12-078 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ** *FIRE DEPARTMENT CONDITIONS * ** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: The installation must comply with all applicable provisions of International Fire Code section 606 Mechanical Refrigeration. 11: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 12: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 15: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M12-078 Printed: 07 -03 -2012 \O\ • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: o= l g 2 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION 4' i E. r14.cc ; fka -\ •Z k tT: „w • Fuel Type: Electric ❑ Gas ❑ Other: FCcO‘• Site Address: Q1Z5 G . 44"‘")‘. Soh Tenant Name: 13De+ nQ{ King Co Assessor's Tax No.: 0003li "-00 l 3 Suite Number: Floor: New Tenant: ❑ Yes IY.No PROPERTY OWNER Name: ',, t\kvr&H Name: E-' ^' 11g� City: P©r.k..L A State: oQ Zip: (-rZ l t Address: 9.7 ZS , . na1 W, cn Sv t 4 City: 1/ ta.. State: \ 1 A Zip: qb((t CONTACT PERSON — person receiving all project communication Name: ',, t\kvr&H Address: zg US A nI e 11g� City: P©r.k..L A State: oQ Zip: (-rZ l t Phone:c 71 _,1404- OS ,a, Fax: c1 1 _tip Li . OSc Email:1_0, . a4A/fttA'. ew,r oicl . COM MECHANICAL CONTRACTOR INFORMATION Company Name: /' I 1 45 ; it eed, , Address: � 45 NE nlfloc'ft _ S� /-1 City: Por�,_ 1 Stalttee: �� Zip:p72.1 , Phone:50- 249 Boo Fax: g71 404 0 S9S Contr Reg No.: P 1At10.77 ZDExp Date: Tukwila Business License No.: QC3 _ 009 3 4 t o Valuation of project (contractor's bid price): $ 1 I O i ODO Describe the scope of work in detail: IINSkv..1t Z eve...vn lerS ; \a cc)ok u n I oca--\ ezk Use: Residential: New Commercial: New Replacement Replacement H:\Applications \Forms - Applications On Line\201 1 Applications\Mechanical Permit Application Revised 8 -9 -I I.docx Revised: August 2011 bh Page 1 of 2 • Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heatlrefrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING I W jl;�'' O' • ?64e1Q Signature: Print Name: Mailing Address: 2— qtt5 /✓ (e ,IU H:\Applications \Forms - Applications On Line \20I 1 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Date: C v r )DI D Day Telep one: S 03-0)16-S196 rot r ^�' �� r 2021 1 l City State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0003400018 Permit Number: M12 -078 Address: 9725 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 05/18/2012 Applicant: BOEING #9 -101 Issue Date: Receipt No.: R12 -02021 Initials: User ID: LAW 1632 Payment Amount: $1,129.65 Payment Date: 06/29/2012 01:57 PM Balance: $0.00 Payee: BRIAN HENDRICKS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 05555C ACCOUNT ITEM LIST: Description 1,129.65 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 1,129.65 Total: $1,129.65 doc: Receiot -06 Printed: 06 -29 -2012 fil City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.ov RECEIPT Parcel No.: 0003400018 Permit Number: M12-078 Address: 9725 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 05/18/2012 Applicant: BOEING #9 -101 Issue Date: Receipt No.: R12 -01617 Initials: User ID: Payee: JEM 1165 Payment Amount: $282.41 Payment Date: 05/18/2012 08:00 AM Balance: $1,129.65 ELLIOT W PARKER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 035773 ACCOUNT ITEM LIST: Description 282.41 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 282.41 Total: $282.41 doc: Receiot -06 Printed: 05 -18 -2012 1A-7 INSPECTION RECORD Retain a copy with permit /P /2-673 PERMIT NO.e_ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 0 Permit Inspection Request Line (206) 431 -2451 1 INSPECTION NO. Project: t acC/tiG Type of Inspection: r= f"A/9C. Address: 9 7.25 FAs; f74 G/iV'k Date Called: Special Instructions: �j °' t / (,Ca2- 7S3 -0 I Date Wanted:. y– G2.0-i2 (a p.m. Requester: Phone No: 50,3-14/2 -- 3/9 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: C-err 1`.k`;!e:.o Inspet or. 1 11 Date: 9 7 6 — ! 2.- n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �-I INSPECTION RECORD'" Retain a copy with permit INSPECTION NO. PERMIT. NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 R._ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Projg3: Type of Inspection: _ Addres .. eir X12 5 � . Awa. JK( Date -all d: 1 - ' -( ti . .�.. Special Instructions: �f J L Date Wanted:. i �a:m„ Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 3 K- i)/\_. Dr nU -I 9 �1 Inspector: Date:. s n REINSPECTION FEE REQUIRED. Prior to next inspection :fee must::;be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule. reinspection. 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: �o e / Duel Cr - / O 1 . T✓-eQ z.et Type of Inspectn: toc_ / A ddress: ci -7 a5-- Suite #: L , 5, wa..... ki,Contact Person:, Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: i`v✓ -Z... - OK, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: s c --- Date: "M "L. Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 *FITE REFRIGERATION DIVISION RAE COkROPAltON Air Cooled Condensing Unit Rating Condensing Unit Model: DD3OL7 Refrigerant: R507 Condenser Capacity @ 1 °F TD: 12202 Circuit 1 Compressor: Fan: CoII: Circuit 2 Compressor: Fan: Coil: Quantity: 1 Quantity: 2 Rows: 3 Quantity: 1 Quantity: 2 Rows: 3 Points outside operating limits omitted. 60 HZ Rating Standard Rating Compressor safety override Is OFF •ti Note: Capacity based on 5 degrees sub cooling P •iP�: . >� ®• Compressor Quantity: Fan Quantity: Altitude: Type: 4DL3 -1500 () Description: 0.5 hp, 24" dia, 1140 rpm FPI: 12 Fin Height: 32.5 Type: 40L3 -1500 () Description: 0.5 hp, 24" dia, 1140 rpm FPI: 12 Fin Height: 32.5 FXLE COPY 2 4 O ft. Fin Length: 83.5 Fin Length: 83.5 Suction Ambient Cond. Temp. Capacity [STUN_ Unit [kw] Unit EER Condenser Capacity [BTUH] TD -25 °F 85 °F 103.1 °F 140,393 26.5 5.3 220,019 18.1 °F -25 °F 95 °F 112.3 °F 127,504 27.2 4.7 209,747 17.3 °F -25 °F 105 °F 121.2 °F 113,620 27.6 4.1 197,567 16.2 °F -20 °F 85 °F 105 °F 157,317 28.4 5.5 242,940 20 °F -20 °F 9,,E 114.1 °F 142.914 29.3 4_9 231 826 19.1 °F -20 °F 105 °F 123 °F 127,262 29.9 4.3 218,638 18 °F -15 °F 85 °F 106.9 °F 175,169 30.3 5.8 266,786 21.9 °F -15 0F 95 °F 115.9 °F 159,086 31.3 5.1 254,656 20.9 °F -15 °F 105 °F 124.8 °F 141,446 32.1 4.4 240,246 19.8 °F -10 °F 85 °F 108.9 °F 193,750 32.2 6 291,453 23.9 °F -10 °F 95 °F 117.8 °F 175,787 33.4 5.3 278,097 22.8 °F -10 °F 105 °F 126.6 °F 156,135 34.4 4.5 262,406 21.6 °F REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 8 2012 City of Tukwila BUILDING DIVISION CORRECTION LTR## CITY V lA JUN 1 2012 PERMIT CENTER We reserve the right to change or revise specifications and product design in connection with any eature of our products. Such changes do not entitle the buyer to corresponding changes, Improvements, additions, or replacements for equipment previously sold or shipped. PO Box 1206 1 Pryor, OK 74362 I Phone (918) 825 -7222 Fax (918) 825 -0723 1 © 2002 -2012 RAE Corporation Report Created On: 3/23/2012 Page 1 of 1 Report Created By: JAYK Application Version: 2012.3.21.1 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: June 4, 2012 Project Name: Boeing #9 -101 Permit # M12 -078 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculation sheets shall be stamped, 1. Please provide the efficiency ratings for the new equipment. W0.s 'ride b. 5c-1e-.5 red �k■e.y du r carry ee: e.enej 2. I could not find the size of the Titen anchor bolts proposed to secure the condensers and the e aporator rack. Th embedment was show v. nee. 5 er. j3eal 'G,1. sea 0\ ec -w,' j3 3. Please add required special inspections to the plans. k fs'or evaft5S, wel4 r\ our 5160p b Cer4. C,64 Should there be questions concerning the above information please contact the Building Division at 206- 431 -3670. CITY JUN 14 2012 PERMIT CENTER June 5, 2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Tom Navratil 2945 NE Argyle Street Portland, OR 97211 RE: Correction Letter #1 Mechanical Permit Application Number M12 -078 Boeing #9-101 — 9725 East Marginal Wy S Dear Mr. Navratil, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and be reflected on your drawings. I have enclosed comments from the Building Department. The Fire Department has no corrections at this time. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, enc File: M12 -078 fer Marshall it Technician W:\Pennit Center \Correction Letters\2012\M12 -078 Correction Letter #I.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: June 4, 2012 Project Name: Boeing #9 -101 Permit # M12 -078 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculation sheets shall be stamped, 1. Please provide the efficiency ratings for the new equipment. 2. I could not find the size of the Titen anchor bolts proposed to secure the condensers and the evaporator rack. The embedment was shown. 3. Please add required special inspections to the plans. Should there be questions concerning the above information please contact the Building Division at 206- 431 -3670. PERMIT COORD p G PLAN REVIEW /RO��I SLIP ACTIVITY NUMBER: M12 -078 PROJECT NAME: BOEING #9 -101 SITE ADDRESS: 9725 EAST MARGINAL WY S DATE: 06/14/12 Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division Public Works ® Fire Prevention ❑ Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 06/19/12 Incomplete ❑ Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route `t" Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/17/12 Approved n Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 02/29/12 »PERMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -078 DATE: 05/18/12 PROJECT NAME: BOEING #9 -101 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: s d(A114 i itux, ` 2, BLildmg Division Fire Prevention 1 Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tuesday /Thursday) DUE DATE: 05/22/12 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required ❑ No Further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/19/12 Approved ❑ Approved with Conditions ❑ Not App'd (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only I I CORRECTION LETTER MAILED: �� 1 Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: A, • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 6 - g - 12 Plan Check/Permit Number: M12-078 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Boeing #9 -101 AEC CRVaprutA IJUW14 2012i PERMIT cEr"EH Project Address: 9725 East Marginal Wy S o Contact Person 1 c'. 1�1ci-J ^c l j Phone Number: Q 7 ( WY-) D S 86 Summary of Revision: AekIee` s 1-1b dC t w,',• 4�� Sheet Number(s): 13.3 2.0 c 4.0 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: /�Ul1nj Entered in Permits Plus on \applications \forms - applications online \revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople Pier Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company PERMACOLD ENGINEERING INC 5032498190 2945 Ne Argyle St Portland OR 97211 Out Of State Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601511020 Active PERMAE1077R0 Construction Contractor 12/20/1993 12/8/2012 Boiler /Steam Fit /Proc Piping Unused d Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WESTOCD099Q0 W E STONE CO DVN /WESCOLD INC Construction Contractor General Unused 11/20/1991 11/1/2001 Archived WESTO**278QE W E STONE / CO INC Construction Contractor General Unused 11/5/1973 11/1/1990 Archived Business Owner Information Name Role Effective Date Expiration Date JACKSON, STEPHEN L President 10/15/2001 Amount CIELOHA, RANDY SCOTT Vice President 09/09/2009 C2064437877 RISTAU, WARD W President 10/20/1993 09/09/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 DEVELOPERS SURETY & INDEM CO 198338C 10/10/2001 Until Cancelled $6,000.00 10/15/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 14 NATIONAL FIRE INS CO OF HARTFO C2064437877 10/01/2009 10/01/2012 $1,000,000.00 09/30/2011 13 CAOLLEY FORGE INS TCP2064437877 10/01/2008 10/01/2010 $1,000,000.00 09/28/2009 12 CAOLLEY FORGE INS TCP2064437877 10/01/2006 10/01/2008 $1,000,000.0009 /26/2007 11 11 TRANSCONTINENTAL INS CO 10/01/2006 $1,000,000.0009 /26/2005 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: / /fortress.wa. gov /lni/bbip /Print.aspx 07/03/2012 AREA OF WORK INDEX: 0.0: COVER ES -1: EQUIPMENT SCHEDULE 1.0: SCHEMATIC 2.0: CONDENSER ELEVATION 3.0: LAYOUT 4.0: RACK WELDMENT ,400/ 9725 E. MARGINAL WAY SOUTH TUKWILA, WA 98108 PACKAGED FREON CONDENSER /EVAP.COIL INSTALL AND PIPING REFRIGERATION DRAWINGS *PERMIT SET* REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal Iand may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical [electrical Gelumbing is Piping City of Tukwila BUILDING DIVISION FILE COPY Permit No., 101' O 7 „„ Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize v,olation of any adopted code or ordnance. Receipt ol approved Field Copy and conditions is acknowledged: By Date: �? – — 12 City Of Tukwila BUILDING DIVISION WASHINGTON STATE CODE COMPLIANCE SPECIFICATION ISSUES & NOTES REVIEWED FOR.•. p0bE COMPLIANCE APPROVED JUN 2 8 2012 t)f- City of Tukwila BUILDING DIVISION 1. REFRIGERATION SYSTEM TO BE IN COMPLIANCE WITH CHAPTER 11 (REFRIGERATION) OF 2009 INTERNATIONAL MECHANICAL CODE AND CHAPTER 6 SECTION 606 (MECHANICAL REFRIGERATION) OF 2009 INTERNATIONAL FIRE CODE. 2. IN ACCORDANCE WITH SECTION 1101.6, REFRIGERATION SYSTEM SHALL BY REFERENCE COMPLY WITH ASHRAE 15 STANDARDS. 3. IN ACCORDANCE WITH SECTION 1103.2, OCCUPANCY CLASSIFICATION IS #6 INDUSTRIAL. 4. IN ACCORDANCE WITH SECTION 1103.3, SYSTEM IS CLASSIFIED AS A HIGH - PROBABILITY SYSTEM. 5. IN ACCORDANCE WITH SECTION 1107.3.1, ALL REFRIGERANT PIPING SHALL BE COPPER PIPE AS SPECIFIED AND SHALL BE PER ANSI /ASME B31.5 STANDARDS. 6. IN ACCORDANCE WITH SECTION 1108, SYSTEM SHALL BE FIELD TESTED PER SPECIFIED REQUIREMENTS. 7. IN ACCORDANCE WITH SECTION 606.5, REASONABLE ACCESS SHALL BE PROVIDED AT ALL TIMES TO FIRE CODE OFFICIALS. 8. IN ACCORDANCE WITH SECTION 606.6.1, BY COPY OF THIS INFORMATION OWNER OF FACILITY HAS OR WILL BE NOTIFIED OF THE PERIODIC TESTING REQUIREMENTS OF THIS SECTION. REL;tivte4 CITY OF TUKWILA SAY 182012 PERMIT CENTER Mir -V11 PROJECT FOR: >- m REVISION SCHEDULE W w 0 • z 0 1— z Q D 0 r ti co 2 ci¢ rn W 12 a m W m Z W Z Z V w O J Z CC 0 0 Oo Z Y LL m W U %0 N (0 N d' W J V N 0 1-- 0 Z Ch L LLI 0 U S z Z 0 2W!I: - W w_uwi� Qzad w Z W 0 re Z > ce�aI- oW Ow 020 ->. ZQOe° ►-- ¢nw.o -wuwi zo�cw .0r- �i w a d Z J ZQ�Z� ¢ Q- W =�WZ('j W< a 0 W~ W E5 J F w W o�awOOZZ OZ°F�►=-Zo v°ZO? §ww oZO«QZQw0° ¢�w°aodo¢z¢ z=r0° wa � aHn.?m© PROJECT NUMBER: 12R —C733 SHEET NUMBER: 0.0 e ENGINEER'S STAMP: 5 /L J AIR COOLED CONDENSER UNIT QUANTITY MAKE AND MODEL SUCTION (PSIG) SST ( °F) CONDENSING }I TR REFRIGERANT V/PH/HZ COMPRESSORS WT.(LBS) WT.(LBS) SUCTION LIQUID OVERALL DIMENSIONS COMMENTS 1 CENTURY DD3OL7 15.8 -22.8 95 11 R -507 460/3/60 2 3253 3097 (2) 2 -1/8" (2) 5/8" 138.75" L x 67.75" W x 63" H 2 CIRCUITS WITH A419 T -STAT EVAPORATORS QUANTITY MAKE AND MODEL LOCATION ROOM TEMP CO TD CO TR FINS PER INCH FEED COIL MATRL NUMBER FANS HP POWER V /PH /HZ TYPE DEFROST PAN MAT 'L CASING MAT 'L SHIPPING WT.(LBS) OPERATING WT.(LBS) LIQUID SUCTION COMMENTS 2 CENTURY PFE 417- 67 -10E COLD ROOM -10 10.8 5.6 4 TXV COPPER 1 3 460/3/60 ELECTRIC ALUM ALUM 808 683 5/8" 2 -1/8" 39.25" L x 61" W x 51.625" H REVIEWED FOR E COMPLIANCE. APPROVED I JUN 2 8 2012 City of Tukwila BUILDING DIVISION crrY IJP i A MAY18 2012 PERMIT CENTER PROJECT FOR: ZgL. P !AEA Wig >- m REVISION SCHEDULE DATE a W d' Engineering, Inc. 3005 N.E. ARGYLE PORTLAND, OR 97211 (503 )-249 -8190 OR (800)-455-8585 FAX (503)- 249 -8322 OREGON LICENSE NUMBER: 95654 WASHINGTON LICENSE NUMBER: PERMAEI077RO CHECKED BY: BFH 4/26/12 SCALE: NOT TO SCALE MEMBER International Institute of a r Ammonia Refrikpration r m z J c STATEMENT OF CONFIDENTIALITY: THE DESIGN AND INFORMATION CONTAINED HEREIN ARE THE PROPERTY OF AND PROPRIETARY TO PERMACOLD ENGINEERING INC. AND MAY NOT BE SOLD, USED, REPRODUCED, OR COPIED BY ANY MEANS IN WHOLE OR IN PART, FOR ANY PURPOSE WHATSOEVER, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF PERMACOLD ENGINEERING INC. © PERMACOLD ENGINEERING. ALL RIGHTS RESERVED E scI PROJECT NUMBER: 12R —C733 SHEET NUMBER: ES -1 ` ENGINEER'S S 4 ` oQ .d . • OA FSSIO r- STAMP: p. MN) V Asio4,04"4, , ME44598co FCISTE,' f� 'vim `�Qr N A% e. J CLEAN -ROOM FLOOR 00 00 00 DD3OL7 CONDENSER L. 2-1/8" FREEZER WALL CONDENSATION TO DRAIN 7/8" ) 5/8" 2-1/8" 2 -1/8" \/(2)/\ 5/811 I s 2-1/8" EVAP 1 EVAP 2 11 , — SEE DETAIL "A" V , V V V - V , V V V V ', V e. 1 e. 1 _ e� • e. I e_ e. I _ e., i•;- 6. 1 V , ` v V ' V • v ,,` V •, .` V V V V • V ' . 1 q '7 _ is_ v _ •' li_ v _ is_ p _ I Q p _ ;'.e v _ 1, I,Q -. p _ I Imo !, 1 • - d e 6 d - d • - d d' d - e P V V V, V' V • V V 17 DETAIL A NOT TO SCALE EVAP 1 EVAP 2 V V V • V V V V V ' V V V V ' V • e- 1 `_ ei 1,"_ 4 e' 1 e' 1 e' 1 4, 1 e' 1 ;_ e' 1 _ e,. 1 ;- _ _ei ••- _ - e, 1 —•` 17 ,.s- 17 • ` v .� V V 1 •,� p • 1:_ 4-, Is_ 6• I.'_ e' 1• _ ' I _ 1.'_ e• �: e• 1:_ - I,_ e' I•_ e''1i_ d• 1:_ • • 1 7 V v • 1 7 , V 7 V ' V •, P r. V V • V• FREEZER WALL 111)=-0748 FLOOR REVIEWED FOR CODE COMPLIANCE APPROVED I JUN 2 8 2012 City of Tukwila eUILDINC3 DIVISION REC:tivt , . CITY OFTUKWLA MAY .18 2012 PERMIT CENTER PROJECT FOR: rd I I WA W r m REVISION SCHEDULE 7DA1 a W Engineering, Inc. 3005 N.E. ARGYLE PORTLAND, OR 97211 l ; (503)-249-8190 OR (800)455 -8585 FAX (503)-249-8322 OREGON LICENSE NUMBER: 95654 WASHINGTON LICENSE NUMBER: PERMAE1077RO CHECKED BY: BFH 4/26/12 I SCALE: NOT TO SCALE International Institute of Ammonia Refrigeration mZ z J I— 0 1 W mi W ■= • mi is STATEMENT OF CONFIDENTIALITY: THE DESIGN AND INFORMATION CONTAINED HEREIN ARE THE PROPERTY OF AND PROPRIETARY TO PERMACOLD ENGINEERING INC. AND MAY NOT BE SOLD, USED, REPRODUCED, OR COPIED BY ANY MEANS IN WHOLE OR IN PART, FOR ANY PURPOSE WHATSOEVER, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF PERMACOLD ENGINEERING INC. © PERMACOLD ENGINEERING. ALL RIGHTS RESERVED PROJECT NUMBER: 12R -C733 SHEET NUMBER: 1.0 ENGINEER'S STAMP: �4y Op VMSf►,,,,c`S�r9 rI4 / 1 ' IONn�e� t vc\-�h , /z• / J ; -4 a i J. • :.. _ • . • 4 .:. :: • . a 1i I i - �!= ! =i�` - i- = !cis' - -!= _lc i -mil loso. �1'��� ■■■• uIII�1111-= 1111 =1111=1111 1111 1111 =" "' — (6) TITEN HD 1/2" X 4 "L ANCHORS SET AND LEVEL CONDENSER AND FRAME BEFORE EMBEDDING TITEN ANCHOR BOLTS. FOLLOW INSTRUCTIONS FOR TITEN HD ANCHORS. (4" DP) DETAIL "A" SCALE: 2/1 • ! •' ..:� •. _ •.: - .4r, •t�� y i � • . i .f _ S . . t ` :•. . • =' :1 �1►e r_4 •I� : l: INI_ "��� �_ �_ `M_ e_ �_ w___ w_ w_ �— �— �_ w_ w-_ 1_ — `s— `�_ W_ !'�► r►`. �► f..� ..-� .� .. !_o • !! ! ! ! o ! o ! o 411M.1.1.0 co �► o 1 � �! !! !_cam l ! c �Ill�n•• ° -- �E�11111�)111�11 11111- 11111111• III IIII�IIII�IIIIE�� 3/16" \ 48" `BOTH SIDES 4" CORRECTION M LTR # REVIEWED FOR CODE COMPLIANCE ,Q APPROVED JUN 2 8 2012 4. t''' City of Tukwila BUILDING DIVISION R V CITY JUN 14 2012 PERMIT CENT 011, PROJECT FOR: i?A di rate m REVISION SCHEDULE ADDED ANCHOR CALL -OUT DATE N \ 00 c0 w < Engineering, Inc. 7c ' 3005 N.E. ARGYLE PORTLAND, OR 97211 (503)-249-8190 OR (800)-455-8585 _ - FAX (503)-249-8322 OREGON LICENSE NUMBER: 95654 WASHINGTON LICENSE NUMBER: PERMAEI077RO milmmemmem CHECKED BY: BFH N CNI c0 Nt SCALE: NOT TO SCALE International Institute of Ammonia Refrigeration z J g o k- il° 0 W•IN STATEMENT OF CONFIDENTIALITY: THE DESIGN AND INFORMATION CONTAINED HEREIN ARE THE PROPERTY OF AND PROPRIETARY TO PERMACOLD ENGINEERING INC. AND MAY NOT BE SOLD, USED, REPRODUCED, OR COPIED BY ANY MEANS IN WHOLE OR IN PART, FOR ANY PURPOSE WHATSOEVER, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF PERMACOLD ENGINEERING INC. ® PERMACOLD ENGINEERING. ALL RIGHTS RESERVED El PROJECT NUMBER: 12R —C733 SHEET NUMBER: 2.0 ENGINEER'S STAMP: A• Milk l q", ��Q� WASy�se$ r,l Il .e ME445984p 4, 'Poi, RFGISTl? FsSIONA1• C `�� f v vt 6/' if J n moirxoe l81 318V1 m CA 1 £X0£ 0£X0 181 1 1767" HuS 11 Fri- 40- 68" 1822 -1 H TUNNEL 1 R20 -1 1 L_ u 88 REVIEWED FOR CODE comPLIANOB APPROVED JUN 2 8 2012 City of Tukwila BUILDING DIVISION 1T20 - -1 C • wtu. CITY TIJKw MAY . 9 8 201 PERMIT CENT 2 PROJECT FOR: .45 FAEZA# TUKWILA, WASHINGTON m I r REVISION SCHEDULE DATE i PermaCo Id CHECKED BY: BFH 5/8/12 11 00 y MEMBER International a r Ammonia Institute of II1 Refrigeration a0 Z K F- o r STATEMENT OF CONFIDENTIALITY: THE DESIGN AND INFORMATION CONTAINED HEREIN ARE THE PROPERTY OF AND PROPRIETARY TO PERMACOLD ENGINEERING INC. AND MAY NOT BE SOLD, USED, REPRODUCED, OR COPIED BY ANY MEANS IN WHOLE OR IN PART, FOR ANY PURPOSE WHATSOEVER, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF PERMACOLD ENGINEERING INC. © PERMACOLD ENGINEERING. ALL RIGHTS RESERVED PROJECT NUMBER: 12R -C733 SHEET NUMBER: 3.0 ENGINEER'S STAMP: �g A• Mq� 4 ME44598 9 w� FsSIONAI%��6 L 1 (2) 16" (2) 46" (2) 1 1T 1 (2) 3714" (8) 014" CLR. HOLE SEE DETAIL 'B' (8) BRACINGS: HSS 2"x2"x1/4" TYP BRACINGS: HSS 2"x2"x1/4" TYP (8) 4 „ \ - \ rr'N) )f 1 16 16 (4) (4) 8"x8"x1/2" PLATE 3"x3"x1/4" ANGLE (4) 72" BRACINGS: HSS 2"x2"x1/4" TYP (8)> 3"x3"x1/4" ANGLE <() 1 6 /\ (16) TITEN HD 3/8" X 3"L ANCHORS DETAIL A SCALE: 2/1 (4) 3/4" A307 SST JAMBNUTS TYP. 60" DETAIL B SCALE: 4/1 3/4" A307 SST THREADED ROD 161" 54" 79" 1 6 BRACINGS: HSS 2"x2"x1/4" TYP 240" BRACINGS: HSS 2"x2"x1/4" TYP SEE DETAIL 'A' 078 REVIEVVED FOR ,4013E COMPLIANCE APPROVED JUN 2 8 2012 City &Tukwila BUILDING DIVISION R•- arl • JUN 1 42.01Z PERMIT CENTER PROJECT FOR: • ra PA EZA TUKWILA, WASHINGTON • ti E T2 ply REVISION SCHEDULE CHANGE TOP ELEVATION OF SUPORT FRAME ADDED ANCHOR CALL -OUT 771177 05/04/12 INI co \ co < Ad PermaCold CHECKED BY: BFH 'Ff I/ I C J 0 R - VI g 2 --Iz ..u- S MEMBER ;liar STATEMENT OF CONFIDENTIALITY: THE DESIGN AND INFORMATION CONTAINED HEREIN ARE THE PROPERTY OF AND PROPRIETARY TO PERMACOLD ENGINEERING INC. AND MAY NOT BE SOLD, USED, REPRODUCED, OR COPIED BY ANY MEANS IN WHOLE OR IN PART, FOR ANY PURPOSE WHATSOEVER, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF PERMACOLD ENGINEERING INC. © PERMACOLD ENGINEERING. ALL RIGHTS RESERVED 11 PROJECT NUMBER: 12R-733 SHEET NUMBER: 4.0 ENGINEER'S STAMP: v1-09 %mu/4 4'4,, d" o 7 ,.I 100 0.71.769 4/4' A*4S/0 N A (D L