HomeMy WebLinkAboutPermit M12-079 - SAHALE SNACKSSAHALE SNACKS 3411 S 120 PL M12 -079 City ATukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 1023049069 Address: 3411 S 120 PL TUKW Project Name: SAHALE SNACKS Permit Number: M12 -079 Issue Date: 06/05/2012 Permit Expires On: 12/02/2012 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA 98168 Contact Person: Name: HEATH HAMBLIN Address: 4102 B PL NW , AUBURN WA 98001 Email: HEATH @UNIVERSALREFRIG.COM Contractor: Name: UNIVERSAL REFRIGERATION INC Address: PO BOX 614 , AUBURN WA 98071 -0614 Contractor License No: UNWERI159RF Phone: 253 - 939 -5501 Phone: 253 939 -5501 Expiration Date: 04/01/2014 DESCRIPTION OF WORK: MODIFY EXISTING DUCTWORK AND REGISTERS TO BE TIER MATCH NEW FLOOR PLAN. REUSE (2) EXISTING WSHP'S. NO NEW EQUIPMENT Value of Mechanical: $13,352.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $355.06 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this ermit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Print Name: Date: 4 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12-079 Printed: 06 -05 -2012 • • PERMIT CONDITIONS Permit No. M12-079 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -079 Printed: 06 -05 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: M is 479 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: Tenant Name: 3L(11 5.120'x' PIN*, SAIAAI€ Socks King Co Assessor's Tax No.: lOZ304— 9(Y Suite Number: /00 Floor: New Tenant: ❑ Yes g..No PROPERTY OWNER // Name: Scan Ccooel iotz Address: (ZZOI u6W 11 A 1414.1iva 444 c• ( . City: C . A1' 1 E State: , c Ztpq$ (Loo CONTACT PERSON — person receiving all project communication Name: aufkAA 1..\ r (∎ t4 Address: 4102 B Plc NW Address: 4102 B Plc NW Phone: (253) 939 -5501 Fax: (253) 735 -3432 City: Auburn State: WA Zip: 98001 Phone: (253) 939 -5501 Fax: Email: I @universalrefrig.com MECHANICAL CONTRACTOR INFORMATION Company Name: Universal Refrigeration Address: 4102 B Plc NW City: Auburn State: WA Zip: 98001 Phone: (253) 939 -5501 Fax: (253) 735 -3432 Contr Reg No.: UNIVERI159RF Exp Date: 04/01/2015 Tukwila Business License No.: zu _oqq St 2a-I Valuation of project (contractor's bid price): $ 13 t 352. • \ ` Describe the scope of work in detail: b�i GAGS ?tNUVLruleo ANb �126G1S�1(2 -j i•a loaL2. milli A ooa.. � Pt • CO�fa (Z collS�-IN t bPSS.. �o ( k) L e41". Use: Residential: New ❑ Replacement ❑ Commercial: New 21 Replacement l Fuel Type: Electric ❑ Gas ❑ Other: iJafrR. Sot)etk tk V vA S (2s) 14;4; ^.34 H:Wpplications\Forms- Applications On Line \2011 ApplicationsVNechanical Permit Application Revised 8.9.11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Z 5 Floor furnace Z Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/ref ig/cooling system (Z,� Air handling unit <10,000 cfin . , • ,3. Unit Type Qty Air handling unit >10,000 cfin Z 5 Evaporator cooler Z Ventilation fan connected to single duct Ventilation system Hood and duct (Z,� Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Z 5 Thermostat Z Wood/gas stove Emergency generator Other mechanical equipment %ak (Z,� USVIIP 5 Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure•will be reviewed and is subject to possible revision by the permit center to comply with current f e e s c h e d u l e s . „ ; , . • • Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Name: Mailing Address: D AGENT: 4102 B Plc NW H:Wpplications\Fonns- Applications On Line \2011 Applicatiorts\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Date: 5/ZZ ( ! 2 Day Telephone: (253) 939 -5501 Auburn WA 98001 City State • Zip Page 2 of2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.Qov RECEIPT Parcel No.: 1023049069 Permit Number: M12 -079 Address: 3411 S 120 PL TUKW Status: PENDING Suite No: Applied Date: 05/24/2012 Applicant: SAHALE SNACKS Issue Date: Receipt No.: R12 -01677 Initials: User ID: WER 1655 Payment Amount: $355.06 Payment Date: 05/24/2012 10:20 AM Balance: $0.00 Payee: UNIVERSAL REFRIGERATION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 44391 355.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 284.05 000.345.830 71.01 Total: $355.06 doc: Receiot -06 Printed: 05 -24 -2012 INSPECTION NO. INSPECTION RECORD Retain a copy with permit X7/2 C75 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 R. (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: Sf' k .') cA //90 K C Type of Inspection: s= AJ9 / Address: .i 10/ S / () P __ Date Called: Special Instructions: Date Wanted:. Requester: Phone No: _7 s -.2 6/ - o5.94( pp`oved per applicable codes. El Corrections required prior to approval. 1- COMMENTS: 7 +644, r /0 p/# Inspe or .. Dat /� .1/ 7/ �. �� (/° /� ,REINSPECTION EE REQUI ED. Prior to r xt inspection, fee must be /' paid at 6300 Southcenter Blv Suite 100.'Call to schedule reinspection. INSPECTION RECORD 'Retain a copy with permit INSPECTION NO. 144 )2 -077 PERMIT NO. ,CITY'OF:TUKWILA BUILDING DIVISION .6300Southcenter Blvd„ #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection;Request Line (206) 431 -2451 Project: ,..,8.;1-k A E. ,J .Z =) Type of Inspection: • I h { b t-t ' I_r,l Address: ' G1,I1 . -j.:26 ?1..m- - Date Called: Special Instructions:; Date Wanted :. (n — {3 l7 Ca. a.m. Requester: Phone No: 6 6., -- 1 0 - 7 ~-1 —7 -7----, pp`ved-per;applicable codes. D Corrections required prior to approval. COMMENTS :' REINSPECTION FEE REQUIRED. Prior to next i . spection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. maw ASSOCIATED AIR BALANCE COUNCIL w Project Name:, SAHALE SNACK$ System: WSHP -1 (EXISTING) AND WSHP -2 (EXISTING) Date: 6/1/12 Page: 1 of 1 AIR DISTRIBUTION DATA TERMINAL NUMBER ROOM NUMBER TERMINAL FACTOR DESIGN TEST (FPM OR CFM) FINAL TYPE 1 SIZE FPM I I CFM TEST1 I 1 TEST2 I TEST3 FPM I CFM WS_ HP -1 (E XISTING) 1 - CD 10x10 - - 250 290 265 255 - 255 2 - CD 10x10 - - 250 285 275 260 - 260 3 - CD 10x10 - - 250 280 270 255 - 255 4 - CD 10x10 - - 250 205 225 240 - 240 5 - CD 10x10 - - 250 215 230 245 - 245 6 - CD 10x10 - - 250 220 230 240 - 240 7 - CD 10x10 - - 250 215 235 245 - 245 8 - _ CD 10x10 - - 250 285 _ 265 255 - _ 255 WSHP -2 (E_ XISTIN_G) 1 - CD 8x8 - - 200 225 215 205 - 205 2 - CD 8x8 - - 200 165 180 190 - 190 3 - CD 8x8 - - 200 165 175 190 - 190 4 - CD 8x8 - - 200 165 180 195 - 195 5 - CD 8x8 - - 200 160 180 190 - 190 6 - CD 8x8 - - 200 235 225 210 - 210 7 - CD 8x8 - - 200 240 220 210 - 210 8 - CD 8x8 - - 200 230 220 205 - 205 Remarks: ¶ERT•COPV • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -079 PROJECT NAME: SAHALE SNACKS SITE ADDRESS: 3411 S 120 PL, SUITE 100 X Original Plan Submittal Response to Correction Letter # DATE: 05 -24 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building WvjG ivisi n Public Works 11. rm Oft oS. f Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 05 -29 -12 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 06-26-12 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Piper Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company UNIVERSAL REFRIGERATION INC 2539395501 Po Box 614 Auburn WA 980710614 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 600599723 Active UNIVERI159RF Construction Contractor 12/6/1985 4/1/2014 Commercial/ Industrial/ Refrig Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status UNIVERIOOOBO UNIVERSAL REFRIGERATION INC Electrical Contractor Hvac /Rfrg Ltd Energy Unused 1/20/2000 1/20/2014 Active Business Owner Information Name Role Effective Date Expiration Date GATES, CHRISTOPHER A President 03/29/2012 Amount GALVIN, BRYAN 5 Vice President 03/29/2012 01CG749762 -8 RAEDER, STEVEN C President 01/01/1980 03/29/2012 VERNON, GUY E 03/20/2012 01/01/1980 01/01/1980 JACKSON, SHELDON G 04/01/2010 01/01/1980 01/01/1980 OSENBAUGH, CHARLES R $1,000,000.00 01/01/1980 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 AMERICAN STATES INS CO EX903622 12/06/2001 Until Cancelled $6,000.00 03/18/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 26 American States Insurance Co 01CG749762 -8 04/01/2012 04/01/2013 $1,000,000.00 03/20/2012 25 American States Insurance Co 01CG7497627 04/01/2010 04/01/2012 $1,000,000.00 03/07/2011 24 AMERICAN STATES INS CO 01CG7497625 04/01/2009 04/01/2010 $1,000,000.00 03/09/2009 23 AMERICAN STATES INS CO 01CG7497624 04/01/2008 04/01/2009 $1,000,000.00 03/11/2008 22 FIRST NAT'LINS CO OF AMERICA 01CG7497623 04/01/2007 04/01/2008 $1,000,000.00 03/01/2007 21 FIRST NATIONAL INS. CO. OF AME 01CG7497622 04/01/2006 04/01/2007 $1,000,000.00 03/13/2006 20 FIRST NATIONAL 01CG749762 04/01/2006 04/01/2007 $1,000,000.00 03/10/2006 https: // fortress .wa.gov /lni/bbip/Print.aspx 06/05/2012 GAS PIPING REGULATOR DETAIL 1 .409.4 MP REGULATOR VALVES A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY AHEAD OF EACH MP REGULATOR • 409.5 APPLIANCE SHUTOFF VALVE EACH APPLIANCE SHALL BE PROVIDED WITH A SHUTOFF VALVE IN ACCORDANCE WITH SECTION 409.5.1,409.5.0, OR 409.5.3 ® VENT LIMITERS E E NT ARE DESIGNED D FOR USE INDOORS AND IN SPACES WHERE LIMITING THE AMOUNT OF GAS ESCAPEMENT DUE TO DIAPHRAGM FAILURE IS CRITICAL. VENT LIMITERS ARE NOT TO BE USED OUTDOORS IF THEY ARE EXPOSED TO THE ENVIRONMENT. 13A15 VENT PROTECTOR IS AVAILABLE FOR OUTDOOR USE WHEN VENT PROTECTION IS REQUIRED. ® 411.1.6 UNIONS A UNION FITTING SHALL BE PROVIDED FOR APPLIANCES CONNECTED BY RIGID METALLIC PIPE. SUCH UNIONS SHALL BE ACCESSIBLE AND LOCATED WITHIN 6 FEET (1829 MM) OF THE APPLIANCE. 5 , 410.1 PRESSURE REGULATORS A LINE PRESSURE REGULATOR SHALL BE INSTALLED WHERE THE APPLIANCE IS DESIGNED TO OPERATE AT A LOWER PRESSURE THAN THE SUPPLY PRESSURE. LINE PRESSURE GAS REGULATORS SHALL BE LISTED AS COMPLYING WITH ANSIZ21.80. ACCESS SHALL BE PROVIDED TO PRESSURE REGULATORS. PRESSURE. REGULATORS SHALL BE PROTECTED FROM PHYSICAL DAMAGE. REGULATORS INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUDOOR INSTALLATION. © A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED BETWEEN THE MP REGULATOR AND ITS UPSTREAM SHUTOFF VALVE. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF A PRESSURE- MEASURING INSTRUMENT AND TO SERVE AS A SEDIMENT TRAP. ( A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED NOT LESS THAN 10 PIPE DIAMETERS DOWNSTREAM OF THE MP REGULATOR OUTLET. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF A PRESSURE - MEASURING INSTRUMENT. OSA DISTRIBUTION /NON- DUCTED RETURN HVAC ABBREVIATIONS SECTION 302.3,53 WSIAQC - OUTDOOR AIR SHALL BE DISTRIBUTED TO EACH ROOM /AREA. WHERE SUPPLY IS SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIRFLOW BY UNDERCUTTING 000RS, TRANSFER GRILLES, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT A MINIMUM 1/2" ABOVE FLOOR COVERING (SEE BELOW). CFM THROUGH DOOR - NO TRANSFER GRILLE FIG. 15 SECTION 25.19 1997 ASHRAE b - r- 1 -- --I ACW= 1 a +b +c +d 600 a - - - -- 0 P = .30 inches I I I 4 1 Assume a, b, c = .1 inches d = .5 inches c ACW= .2 inches Average door measurements ACW inches 1 = .2 ,2 avg. crack width (ACW) d Now correlate to pressure differential of acceptable AP =.15 inches HrO NOTE: . ROOMS SUPPLIED WITH .15 CFM = CFM *.683 (.30 = CFM 400 CFM OR MORE 1 )55 REQUIRE TRANSFER GRILLES (�P .15i) 600 x .68 = 408 CFM 9. THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL GAS PIPING REGULATOR DETAIL 1 .409.4 MP REGULATOR VALVES A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY AHEAD OF EACH MP REGULATOR • 409.5 APPLIANCE SHUTOFF VALVE EACH APPLIANCE SHALL BE PROVIDED WITH A SHUTOFF VALVE IN ACCORDANCE WITH SECTION 409.5.1,409.5.0, OR 409.5.3 ® VENT LIMITERS E E NT ARE DESIGNED D FOR USE INDOORS AND IN SPACES WHERE LIMITING THE AMOUNT OF GAS ESCAPEMENT DUE TO DIAPHRAGM FAILURE IS CRITICAL. VENT LIMITERS ARE NOT TO BE USED OUTDOORS IF THEY ARE EXPOSED TO THE ENVIRONMENT. 13A15 VENT PROTECTOR IS AVAILABLE FOR OUTDOOR USE WHEN VENT PROTECTION IS REQUIRED. ® 411.1.6 UNIONS A UNION FITTING SHALL BE PROVIDED FOR APPLIANCES CONNECTED BY RIGID METALLIC PIPE. SUCH UNIONS SHALL BE ACCESSIBLE AND LOCATED WITHIN 6 FEET (1829 MM) OF THE APPLIANCE. 5 , 410.1 PRESSURE REGULATORS A LINE PRESSURE REGULATOR SHALL BE INSTALLED WHERE THE APPLIANCE IS DESIGNED TO OPERATE AT A LOWER PRESSURE THAN THE SUPPLY PRESSURE. LINE PRESSURE GAS REGULATORS SHALL BE LISTED AS COMPLYING WITH ANSIZ21.80. ACCESS SHALL BE PROVIDED TO PRESSURE REGULATORS. PRESSURE. REGULATORS SHALL BE PROTECTED FROM PHYSICAL DAMAGE. REGULATORS INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUDOOR INSTALLATION. © A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED BETWEEN THE MP REGULATOR AND ITS UPSTREAM SHUTOFF VALVE. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF A PRESSURE- MEASURING INSTRUMENT AND TO SERVE AS A SEDIMENT TRAP. ( A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED NOT LESS THAN 10 PIPE DIAMETERS DOWNSTREAM OF THE MP REGULATOR OUTLET. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF A PRESSURE - MEASURING INSTRUMENT. HVAC LEGEND INLINE EXHAUST FAN(S) ROOFTOP EXHAUST FAN SIDEWALL EXHAUST FAN VAV FAN BOX CEILING EXHAUST FAN GAS METER ZD12 VVT DAMPER �Q. THERMOSTAT X T -BAR SUPPLY DIFFUSER T -BAR RETURN GRILLE HARDLID SUPPLY DIFFUSER HARDLID RETURN GRILLE FD FSD •- FIRE SMOKE DAMPER pi 1= VOLUME DAMPER SD ■ SMOKE DETECTOR MMw FLEXIBLE DUCT SARA ROUND DUCT UP ROUND DUCT DOWN r1 Ox10 CD\ 11300 CFM -10 "o/ DIFFUSER TAG REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a nev plan submittal and may include additional plan rovisw fees. OSA INTAKE (THROUGH ROOF) ECONOMIZER HVAC NOTES HVAC ABBREVIATIONS 1. DUCT INSULATION SHALL MEET REQUIREMENTS OF SECTION 1414.2 OF THE 2009 WSEC AND TABLE 14 -5. 2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN AIR DUCTS PER SECTION 606 OF THE 2009 IMC. HVAC SMOKE DUCT DETECTORS SHALL SHUT DOWN POWER TO THE UNIT UPON ACTIVATION AND A "SUPERVISORY" ZONE SHALL BE INITIATED AT FIRE ALARM PANEL UPON SMOKE DUCT DETECTOR ACTIVATION. IMC SECTION 606.2.1. 3 DUCTWORK- MAINTRUNK IS R -4.2 IN CONDITIONED SPACES AND R -8 IN UNCONDITIONED SPACES AS PER THE WSEC. 4. ALL SINGLE PACKAGE HVAC UNITS SHALL BE INSTALLED AFF BDD BTUH CD CFM DB DEG DH DN EA EER EG ESP EWT EXH FCU FD FPM FSD GA GF GPM GRD GWB HP ID IRH KW MBH MCD NC NIC NTS OBD OC OD OSA PD RPM. RA RAG SA SG SP SSG TBD TG TYP VAV VFD VTR I VVT ABOVE FINISHED FLOOR BACKDRAFT DAMPER BRITISH THERMAL UNIT PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE DECIBEL DEGREE DUCT HEATER DOWN EXHAUST AIR ENERGY EFFICIENCY RATIO EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST FAN COIL UNIT FIRE DAMPER, FLOOR DRAIN FEET PER MINUTE FIRE AND SMOKE DAMPER GAUGE GAS FURNACE GALLONS PER MINUTE GRILLE, REGISTER, DIFFUSER GYPSUM WALLBOARD HORSEPOWER, HEAT PUMP INSIDE DIMENSION INFRARED HEATER KILOWATT THOUSAND BTU PER HOUR MOTORIZED CONTROL DAMPER NOISE CRITERIA NOT IN CONTRACT NOT TO SCALE OPPOSED BLADE DAMPER ON CENTER OUTSIDE DIMENSION OR DIAMETER OUTSIDE AIR PRESSURE DROP REVOLUTIONS PER MINUTE RETURN AIR RETURN AIR GRILLE SUPPLY AIR SUPPLY GRILLE STATIC PRESSURE SIDEWALL SUPPLY GRILLE TO BE DETERMINED TRANSFER GRILLE TYPICAL VARIABLE AIR VOLUME VARIABLE FREQUENCY DRIVE VENT TO ROOF VARIABLE VOLUME AND TEMPERATURE AND SHALL OPERATE, PER W.S.E.C. 2009, SECTION 1413. 5. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON -SITE HVAC LEGEND INLINE EXHAUST FAN(S) ROOFTOP EXHAUST FAN SIDEWALL EXHAUST FAN VAV FAN BOX CEILING EXHAUST FAN GAS METER ZD12 VVT DAMPER �Q. THERMOSTAT X T -BAR SUPPLY DIFFUSER T -BAR RETURN GRILLE HARDLID SUPPLY DIFFUSER HARDLID RETURN GRILLE FD FSD •- FIRE SMOKE DAMPER pi 1= VOLUME DAMPER SD ■ SMOKE DETECTOR MMw FLEXIBLE DUCT SARA ROUND DUCT UP ROUND DUCT DOWN r1 Ox10 CD\ 11300 CFM -10 "o/ DIFFUSER TAG REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a nev plan submittal and may include additional plan rovisw fees. OSA INTAKE (THROUGH ROOF) ECONOMIZER SCOPE OF WORK JOB #12107 1. INSTALL DUCTWORK AND GRILLES FOR (2) EXISTING WATER SOURCE HEAT PUMPS. SUPPLY AIR DUCT WSHP -1,2 (EXISTING) I� 0 D 50 t'0 "0 200ICFM MEZZANINE SLEEPERS FILTER RACK BPIF XISTING) CEILING GRID WiTiMMET NAT. GAS SEPARATE PERMIT REQUIRED FOR ❑' Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION J REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2012 50 CFM-1O" 0 :�I !EMU �U 1ST FLOOR 00 CFM DETAIL - TYPICAL GAS FURNACE INSTALLATION SCALE: NTS HVAC PLAN SCALE: 1,1411=11-0" L NOTE: These plans are diagrammatical only Please verify all dimensions at job site. PENDING CITY APPROVAL) uI REFRIGE - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939 -5501 TACOMA: (253) 922 -3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 °UNIVERSAL REFRIGERATION DRAWING -2001 DESCRIPTION REVISION 0 N N w cc w z Q z w J 2 C0 CIO CD PRINT /PLOT DATE: 5/22/12 PROJECT START DATE 5/22/12 DRAFTER: CFN DESIGNER: HH PROJECT MANAGER: HH JOB NUMBER: 12107 SHEET NUMBER: M -1 HVAC NOTES 1. DUCT INSULATION SHALL MEET REQUIREMENTS OF SECTION 1414.2 OF THE 2009 WSEC AND TABLE 14 -5. 2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN AIR DUCTS PER SECTION 606 OF THE 2009 IMC. HVAC SMOKE DUCT DETECTORS SHALL SHUT DOWN POWER TO THE UNIT UPON ACTIVATION AND A "SUPERVISORY" ZONE SHALL BE INITIATED AT FIRE ALARM PANEL UPON SMOKE DUCT DETECTOR ACTIVATION. IMC SECTION 606.2.1. 3 DUCTWORK- MAINTRUNK IS R -4.2 IN CONDITIONED SPACES AND R -8 IN UNCONDITIONED SPACES AS PER THE WSEC. 4. ALL SINGLE PACKAGE HVAC UNITS SHALL BE INSTALLED WITH ECONOMIZERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS PER I.M.C. 2009, SECTION 403, CHAPTER 6, AND SHALL OPERATE, PER W.S.E.C. 2009, SECTION 1413. 5. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON -SITE FOR INSPECTIONS. 6: ALL HVAC EQPM. TO BE LABELED TO THE SPACE SERVED. 7. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE VERTICAL AT 12' -0" MAX., HORIZONTAL AT 10' -0" MAX. WITH STRAP, OR 8' -0" MAX. F TRAPEZE SUPPORT. 8. THERMOSTAT TO BE SEVEN -SAY TYPE AND HAVE NIGHT SETBACK WITH 5 DEGREE DEADBAND. 9. THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 1416 WSEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, O &M MANUALS, SYSTEM BALANCE REPORT, AND A COMM- ISSIONING REPORT. 10. DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC 1414.1. DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -18: EXTENT OF SEALING IS AS FOLLOWS: a. STATIC PRESSURE: 1/2" TO 2' SEAL TRANSVERSE JOINTS. b. STATIC PRESSURE 2: 2" TO 3"; SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. c. STATIC PRESSURE: ABOVE 3 "; SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS. 11. NREC FORMS, DUCTING PLANS (BALANCING FEATURES), AS WELL AS VIAQ INFORMATION IS REQUIRED ALONG WITH A MECH. PERMIT AT THE TIME OF THE TENANT IMPROVEMENT PERMIT. 12. PIPING INSULATION SHALL MEET THE REQUIREMENTS OF 1415 OF THE WSEC: - TABLE 14-8 MAN PIPE INSULATION IMO OPWAT1N9 •I . RAN 'F ri' i I' ' •7 •r Blu- in/h- F12 -'F , '' 7 TEIP. 'F •;I "i I UP TO 2 ", l . > . . LESS HEMS SYSTEMS SIEAII, SIM CONDENSATE IMO HOT WATER NOM & L NSULA11ON THICKNESS hri I. 251-350 0.29 -0.31 200 1.5 10 2.5 2.5 3.5 3.5 201 -250 0.27 -0.30 150 1.0 1.5 1.5 2.0 2.0 3.5 141 -200 0.25 -0.29 125 0.5 1.5 1.5 1.5 1.5 1.5 105 -140 0.24-0.28 100 1.5 1.0 1.0 1.0 1.5 1.5 IIIi!ve 11 ;1tliZM r� MIMEIMl�)•l�!<�MNIM�iF.. =II!: ..EM (BELOW 40 0.23-0 75 1.0 1.5 1.5 1.5 1.5 SCOPE OF WORK JOB #12107 1. INSTALL DUCTWORK AND GRILLES FOR (2) EXISTING WATER SOURCE HEAT PUMPS. SUPPLY AIR DUCT WSHP -1,2 (EXISTING) I� 0 D 50 t'0 "0 200ICFM MEZZANINE SLEEPERS FILTER RACK BPIF XISTING) CEILING GRID WiTiMMET NAT. GAS SEPARATE PERMIT REQUIRED FOR ❑' Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION J REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2012 50 CFM-1O" 0 :�I !EMU �U 1ST FLOOR 00 CFM DETAIL - TYPICAL GAS FURNACE INSTALLATION SCALE: NTS HVAC PLAN SCALE: 1,1411=11-0" L NOTE: These plans are diagrammatical only Please verify all dimensions at job site. PENDING CITY APPROVAL) uI REFRIGE - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939 -5501 TACOMA: (253) 922 -3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 °UNIVERSAL REFRIGERATION DRAWING -2001 DESCRIPTION REVISION 0 N N w cc w z Q z w J 2 C0 CIO CD PRINT /PLOT DATE: 5/22/12 PROJECT START DATE 5/22/12 DRAFTER: CFN DESIGNER: HH PROJECT MANAGER: HH JOB NUMBER: 12107 SHEET NUMBER: M -1