Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M12-082 - WESTFIELD SOUTHCENTER MALL - TCBY
TCBY 1119 SOUTHCENTER MALL M12 -082 �J��I�L wqs City o Tukwila Department of CormnuniO, Develo p ment 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 1119 SOUTHCENTER MALL TUKW Project Name: TCBY Permit Number: M12 -082 Issue Date: 07/19/2012 Permit Expires On: 01/15/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: BRET RYAN Address: 16435 N SCOTTSDALE RD, #195 , SCOTTSDALE AZ 85254 Email: BRET.RYAN @FITCH.COM Contractor: Name: SAYBR CONTRACTORS INC Address: 3852 S 66 ST , TACOMA WA 98409 Contractor License No: SAYBRCI033L7 Phone: 480 998 -4200 Phone: 206 - 439 -2144 Expiration Date: 06/14/2014 DESCRIPTION OF WORK: REVISE MECHANICAL LAYOUT TO MATCH NEW TENANT IMPROVEMENT LAYOUT /REQUIREMENTS Value of Mechanical: $10,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $306.06 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: - • 1d_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12-082 Printed: 07 -19 -2012 • PERMIT CONDITIONS Permit No. M12-082 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. doc: IMC -4/10 M12 -082 Printed: 07 -19 -2012 Site Address: • CITY OF TUKWILA Community Development Deportment Permit Center 6300 Southeenter Blvd, Suite 100 Tukwila, WA 98188 http://www.Tukv, i la WA .gor • . • - Mechanical Permit No. Project No. Let ) Date Application Accepted: Date Application Expires:'‘ 1,1 7)(7 2_ : (For,Office use on y MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Tenant Name: 7-e•' & ncirtk e...ev—PrEva—glVeg , ,,lefftetV3Aii■iillieloA.1.1' Tr 7 ' 1 ti ''' ,.. Name: -Z44, 'MILL 0 i•-)9 LA-C , Address: ctz,; r Tit pL. Ne- City: wm op State: IAA+ Zip:719057z_ Voi■iiVii,.•i'—' - ' ' ' 1:-....e, —.4.1 ' ' • ,,,P RSON',.-- eiSo- - ' - - " - fiWeitildi'll.iki■;;'0;2...;:;,,-.-*:•':;:',41.):-'!'..: w-recP-1.,T8.all Prq./eCt — :- Name: ,-- /Devr" 127A K.) Address: gp • (--or4dAtE *t95- fliPer;c-N C City: Zi • 4444;4 a c .,.,— State: -1.---. Pe . Phone: . 419& , tizoo Fax: cf.'s,. rci- cvs-7z7-, Email: FIC‘r% Afet4-1-e Frvet. coil King Co Assessor's Tax No.: Suite Number: PAO Floor: New Tenant: Yes 0 „No Valuation of project (contractor's bid price): $ 49( 0°C) ivCertt,t . Aur-K pr.0 70)44P--. 11 Piove /'iC.fr Describe the scope of work in detail: Use: Residential: New Commercial: New Fuel Type: Electric Replacement Replacement 11%"& Gas El Other: H:1ApplicalionsWorms-Applications On Line \201 Applicalions■Mechanical Permit Application Revised 8-9-11.docs Revised: August 2011 bh Page 1 of 2 Company Name: Address: . ft _ City: ,..... State: ' . Zip: ,, _ .;• Phone: - . . ^ --- . 1 ...- - . 4 Contr Reg No.: . Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 49( 0°C) ivCertt,t . Aur-K pr.0 70)44P--. 11 Piove /'iC.fr Describe the scope of work in detail: Use: Residential: New Commercial: New Fuel Type: Electric Replacement Replacement 11%"& Gas El Other: H:1ApplicalionsWorms-Applications On Line \201 Applicalions■Mechanical Permit Application Revised 8-9-11.docs Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended /wall /floor mounted heater Appliance vent I Repair or addition to heat/refiig/cooling system t Air handling unit <10,000 cfm Unit Type Qty. Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system t Hood and duct Incinerator— domestic Incinerator — comm/industrial • Unit Type Qty Fire damper Diffuser Thermostat t Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp/I,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Date: g• Z5 / Z-- Day Telephone: gee '448' tlLOO Mailing Address: r GC, /4,1,/ 5 5 IQ • �0re-A - / 2 City State Zip HAApplicationsTonns- Applications On Line\2011 Applications Mechanical Permit Application Revised 8.9.11.docs Revised: August 2011 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT ParcelNo.: 9202470010 Permit Number: M12 -082 Address: 1119 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/30/2012 Applicant: TCBY Issue Date: Receipt No.: R12 -02163 Initials: User ID: Payee: WER 1655 Payment Amount: $244.85 Payment Date: 07/19/2012 09:01 AM Balance: $0.00 VING ZHANG TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 01919G ACCOUNT ITEM LIST: Description 244.85 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 244.85 Total: $244.85 doc: Receiot -06 Printed: 07 -19 -2012 Cit,of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT Copy Reprinted on 05 -30 -2012 at 13:05:18 05/30/2012 RECEIPT NO: R12 -01730 Initials: JEM Payment Date: 05/30/2012 User ID: 1165 Total Payment: 1,247.04 Payee: PING RU ZHANG, ZW TRILLIONS LLC SET ID: S000001752 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D12 -183 EL12 -0500 M12 -082 PG12 -110 TOTAL: 1,063.99 66.13 61.21 55.71 1,063.99 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 1,247.04 TOTAL: 1,247.04 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 TOTAL: 66.13 1,180.91 1,247.04 ii, INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit.Inspection Request Line (206) 431 -2451 r- (112_ 082. Project: Type of Inspection: Address: 11 I. C So C r`n A LL_- Date Called: K Special Instructions: Date Wanted:. (a.m. —.2. r- r2 p.m. Requester: Phone No: v -5IO- GG'yZ- jApproved per applicable codes. Corrections required prior to approval. COMMENTS: 9"iw►i-I( °owlo /t /P Dates Inspec (: lit4.64..7 /EINSPECTION FEE REQUIRE Prior to next inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 ° R:(206) 431- 3670... Permit Inspection Request Line (206) 431 -2451 Project E �+Q� Type o Inspect AC' = J6( -." 1t t Address: 4tc1 Sc ik,tA--(( Date Called: Special Instructions: Date Wanted: .?"-a.m. Requester: Pho a No: 94 2— Approved per applicable codes. COMMENTS: ElCorrections required prior to approval. r ti Date Inspector) R�9NSPECTION FEE REQUIRED. Prior to next Inspection :fee must be - ' paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.. 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project I) �% Info l +t1_ i -ct TCBY Capacity2 Btu /h Total CFM Date 5/25/2012 . cuec® IPLV3 WESTFIELD SOUTHCENTER MALL GREENHECK SQ -100 -B For Building Dept. Use 0.25 TUKWILLA, WA 98188 VFD REVIG ODE _ V1IED FOR COMPLIANCE APPROVED f !na�4 Applicant Name: DON PENN CONSULTING ENGINEER Applicant Address: pP 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 7 51 5C1 Applicant Phone: 817 -410 -2858 Project Description Briefly describe mechanical system type and features. Includes Plans 17 20.12 BUILDof Tukvvila NG DIVISION Drawings must contain notes requireing compliance with commissioning requirements - Section 141 Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name' Model.No.1 Capacity2 Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location GREENHECK SQ -100 -B 750 0.25 1/6 VFD KITCHEN SF -1 GREENHECK SQ -100 -B 750 0.25 1/6 VFD KITCHEN MAY 3 0 2012 PERMIT CENTER a t2.......003/04e Heating Equipment Schedule Equip. ID Brand Name' Model No.1 Capacity2 Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh crTYRrArtgliA Efficiency.' GREENHECK SQ -100 -B 750 0.25 1/6 VFD KITCHEN SF -1 GREENHECK SQ -100 -B 750 0.25 1/6 VFD KITCHEN MAY 3 0 2012 PERMIT CENTER a t2.......003/04e Fan Equipment Schedule Equip. ID Brand Name' Model No.1 CFM Sp' HP /BHP Flow Controls Location of Service EF -1 GREENHECK SQ -100 -B 750 0.25 1/6 VFD KITCHEN SF -1 GREENHECK SQ -100 -B 750 0.25 1/6 VFD KITCHEN a t2.......003/04e 'If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? Aa ,,,^ If Heating Only: 9 Y � <5000 cfm? ❑ <70 /o outside air. <70% da Deeisiim Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the... e# Complex System or Systems Analysis Options must be used. CSTART ) tASystem Type Heating Only Heating /Cooling or Cooling Only Reference Section 1421 Yes — No Yes* Reference `Section 1423 otal Ca . wo economize <240,000 Btuh or 10 %? Ai-4'10,451.'36 .1 l '13 Simple System Yes _► Allowed (section 1420) Use Complex ► Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address TCBY Model No.' Date 5/25/2012 Total CFM WESTFIELD SOUTHCENTER MALL SEER or EER For Building Dept. Use Location TUKWILLA, WA 98188 Applicant Name: DON PENN CONSULTING ENGINEER Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 76051 Applicant Phone: 817 -410 -2858 Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option Simple System Q Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity2 Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity2 Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP' HP /BHP Flow Controls Location of Service 'If available. 2 As tested according to Table 14 -1A through 14-1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: Constant vol? Split system? Air cooled? Packaged sys? <20,000 Btuh? Economizer included? If Heating Only: <5000 cfm? <70% outside air? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only Heating /Cooling or Cooling Only Reference Section 1421 J Reference Section 1423 otal Ca . wo economize <240,000 Btuh or 10 %? Simple System Allowed (section 1420) Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical - Complex Systems Checklist MECH -COMP Nonresidential Energy Code Compliance Forms Revised July 2007 2006 Washington State Project Address TCBY Date 5/25/2012 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH- CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY 1431.1 Field assem. sys. Provide calculations 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2.1 Air system reset Indicate automatic reset 1432.2.2 Hydronic System Indicate automatic reset, cooling tower, & heat pump loop valves 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. 1433 Water Economizer Indicate water economizer and provide calculations if 1433 Exception 2 is utilized 1434 Separate air sys. Indicate separate systems on plans 1435 Simul. htg. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency 1438 Variable flow sys. Indicate variable flow on fan and pump schedules 1439.1 Kitchen Hoods Indicate uncooled and unheated make -up air 1439.2 Fume Hoods Indicate VAV, unheated /uncooled or heat rec. makeup no ' is circiea Tor any question, proviae expianatlon: Decision Flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the Start Here T Section 1411.1 Equipmen Efficiency Shall Meet Tables 14 -1A through 14 -1G as /Oil Furnac input > 225,000 tuh or Gas /O' t Heat Yes 4, Any Fuel Furnac input > 225,000 Btuh? Air System Serving Multiple Zones? apacity of H Heating System > 00,000 Btuh 1411.1 Intermittent Ignition Device & Power Venting or Damper. If input >_ 225,000 Btuh then 1412.6 Modulating or Staged Combustion Controls Required Yes l 1411.1 0.75% Maximum Jacket Loss Yes 1 Section 1431.1 Calculations of Total On -Site Energy Input & Ouput Required Yes i Section 1432.2.1 Supply Air Reset Controls Required Yes No Section 1432.2.2 Hot Water Supply Temperature Reset Required (continued on back) 1 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical - Complex Systems (back) MECH -COMP 2006 Washington State Nonresidential Energy Code Compliance Forms �0% Air Econ Provided? Section 1413 Yes Total Clg Capacity w/ Water Econo <500 Tons Yes tal Cap. / cono <= 480,00 Btuh or 20% of otal Cap.? V Section 1433 Economizer Required Yes Yes Yes Yeses Section 1436 50% Effective Heat Recovery Required otor Incl.! qpmt. Covr'd by Tbl 14- 1A -14- 1G? Yes Multi -speed Motor in Multi - eed system stem or Zon w/ Simultaneous Htg. & Clg.? Section 1435 Zone Controls Must Reduce Supply Air Quantity Before Reheating Recooling No--* Application Involves Variable Flow? Section 1437. Motors Must Meet Efficiencies in Table 14 -4 Section 1438 Variable Flow Devices Required No DONE Section 1439.1 No Heating or Cooling for at Least 50% of Make -up Air Section 1439.2 One Required: a. 50% VAV Exhaust & Make -up b. 75% Direct Makeup w/ Tempering Only c. Heat Recovery per 1436 d. Constant Volume w/ < 50fpm Face Velocity Yes Revised July 2007 2006 Washinston State Nonresidential Energ Code Compliance Form Electric Motors MECH -MOT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address TCBY Date 5/25/2012 Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). For Building Department Use Motor No. or Location HP Type (open /closed) Description of Application or Use Synch. Speed Min.Nom. Full load Efficiency cloned 1200 closed 1200 closed 1200 Minimum Nominal Full-Load Efficienc Synchronous Speed (RPM) HP 1.0 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 Open Motors Closed Motors 3,600 1,800 1,200 3,600 I 1,800 1 1,200 Efficiency ( %) Efficiency ( %) - 82.5 80.0 75.5 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 92.4 91.7 91.0 92.4. 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 93.0 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93.0 94.1 93.6 93.0 94.1 93.6 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95.0 Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- 1A or 14 -1B) . 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address TCBY Date 5/25/2012 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington-State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule n.a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls n.a. 1412.1 Temperature zones Indicate locations on plans n.a. 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat n.a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types n.a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control n.a. 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans n.a. 1423 Economizers Equipment schedule 1413 Air economizers n.a. 1413.1 Air Econo Operation Indicate 100% capability on schedule n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n. a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems n.a. 1414.1 Duct sealing Indicate sealing necessary n.a. 1414.2 Duct insulation Indicate R -value of insulation on duct n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements n.a. 1416.2.1 Commissioning Provide commissioning plan n.a. 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing n.a. 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training n.a. 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report n.a. 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. yes 1441 Elec. water heater Indicate R -10 insulation under tank P4.0 yes 1442 Shut -off controls Indicate automatic shut -off P4.0 yes 1443 Pipe Insulation Indicate R -value of insulation on piping P4.0 n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover no is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, theh the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0,75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. • ' Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2,hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 °F dry- bulb /40 °F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 °F dry -bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. • 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or EF CAE • < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. • ' Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2,hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 °F dry- bulb /40 °F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 °F dry -bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. • 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2006 Washington State Nonresidential Energy Code Compliance Form le IL.M.L fledlllly dnu uuuuny bybtelllb wiul ue� lyu bumpy h. did ubutdleu nuns ule eAtenul wnu do duwntduu mtut -uu UduuI Jel wnIFllylny with Section 1412.4.1. - air capacities exceeding 10,000 cfm shall have optimum start controls, Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. 4* Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Project Summary PRJ -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address TORY Date 7/10/2012 WESTPIELD SODTHCENTER MALL For Building Department Use TDEWILA, WA 98188 Applicant Name: DONPENN CONSULTING ENGINEER ApplicantAddress: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX 76051 Applicant Phone: 817 - 410 -2858 FILE COPY Feuer !lc). R CEIV D CITY OF Tu LA JUL 1 12012 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2012 City of Tukwila BUILDING DIVISION CORRECTION LTR# MV2Oi2 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address TCBY Date 7/10/2012 WESTFIELD SOUTHCENTER MALL TUKWILA, WA 98188 Applicant Name: DONPENN CONSULTING ENGINEER Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, T% 76051 Applicant Phone: 817- 410 -2858 For Building Department Use Project Description Compliance Option ❑ New Building ❑ Addition 0 Alteration ❑ Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. 0 Prescriptive Q Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed ❑ Less than 60% of the fixtures new, installed wattage not+increased„& space use not changed. Maximum Allowed Lighting Wattage Location (floor plan /room #) , , Occupancy Description • .."Allowed �•�..� Watts per ft2 ." Gross interior 2 Area in ft . nom,.. ,,. A Iowedrx Area let Floor Re'staur`ant , ", ,. 4 84 : , ` " 1.22 494 603 Basement Storage /W trehoiusa' ,. t ' - t r, . 0.50 206 103 Basement 2x4 Linear fluorescent - 3 bulb 28w 78 1 84 From able 15 -1 (over) - document,all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watts 706 Location • (floor plan /room #) i t , ., , ,,, Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 1st Floor 2x4,Lineer .fluoirescent..x+ 3 •buib,28w. T8 4 84 336 1st Floor 6" recessed downlight' - 1 'four pin 26W CFL 6 26 156 let Floor Track - 100w current limiting device 1 100 100 Basement 2x4 Linear fluorescent - 3 bulb 28w 78 1 84 84 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 676 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the Tamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 1 • a. ; IM 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary (back) LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Prescriptive Spaces Occupancy: Q Warehouse or Parking Garage Qt. Other Qualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights, -1 Unit Lighting Power Allowance ILPA Use LPA (who Use' LPA` (W /ft ) Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias,-fast food establishments', restaurants/bars5 1.20 Police and fire stations 0.90 Dormitory 0.85. Post office 1.00 Dweling Units 1.00 Retail1', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.3 3 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 U IVLCi7 ,IVI 14UIC 1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in-which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w/fl2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2 10) Display window illumination installed within 2 feet of the window, provided that the display window Is separated from the retail space by walls or at least three-quarter-height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: 1, 0.6 watts per square foot of sales floor area not listed in items Ii and iii below; ii. 1.4 watts per square foot of fumiture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only If the merchandise display luminaires comply with all of the following: (a) Located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. . 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Lighting Power Allowance Adjustments LTG -LPA 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Project Address ITCBY Revised December 2010 'Date 7/10/2012 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15.1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor plan /room #) Occupancy Description Allowed Watts per ft2" Ceiling Height for this room Ceiling Height limit for this exception ** Adjusted LPA Watts per ft2 Restaurant Restaurant 1.20 10.0 feet 9 feet 1.22 "" From Table 15 -1 based on exceptions listed in footnotes 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address . TCBY (Date 7/10/2012 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements . in the 2009 Washington State Nonresidential Ene gy.Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) Yee 1513.1 Local control /access Schedule with type, indicate locations E2.1, 82.2 Yea 1513.2 Area controls Maximum limit per switch 82.1, 82.2 N.A. 1513.3 Daylight zone control Schedule with type and features, indicate locations N.A. vertical glazing Indicate vertical glazing on plans N.A. overhead glazing Indicate overhead glazing on plans Yee 1513.4 Display /exhib /special Indicate separate controls B2.1, 82.2 N.A. 1513.5 Exterior shut -off Schedule with type and features, indicate location N.A. (a) timer w /backup Indicate location N.A. (b) photocell. Indicate location N.A. 1513.6 Inter. auto shut -off Indicate location N.A. 1513.6.1 (a) occup. sensors Schedule with type and locations N.A. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans N.A. 1513.7 Hotel/motel controls Indicate location of room master controls N.A. 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section. 1514) Yee I 1514 [Max. watts [Indicate watts for each exit sign 81.1 LIGHTING POWER ALLOWANCE (Section 1530 -1532) Yea 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture N.A. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) Yee I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency 141.1 TRANSFORMERS (Section 1540) Yea [ 1540 [Transformers 'Indicate size and efficiency Is3.0 I no" is circled for any question, provide explanation: tte,t41 tt 3 TWIN TWIST, GRAVITY ;,1 SOFT SERVE /YOGURT FREEZE F231 APPROVED JUL 17 2012 City of Tukwila UILDING DIVISION STOELTING' • Precision controlled refrigeration system designed for quality product consistency from the first cone to the last. • IntelliTec 2TM control communicates with the operator through a multiline graphics LCD display using full text instructions. • Energy Conservation Mode (ECM) protects product from over- agitation during slow or non -draw periods. • Compact design with a small footprint ideal choice for locations where space is an issue. • Proprietary auger design gently folds mix and prevents product breakdown, producing a smoother, creamier product. • Clear door shows visible moving product for merchandising appeal. • Self- closing spigot eliminates waste and assures precise portion control. • Spigot handle height meets ADA requirements for self service locations. • Adjustable dispense rate for optimal product output. • Long- wearing parts offer lower preventative maintenance costs. • Built for ease of operation and cleaning. • Twist feature allows you to serve two flavors individually or combine flavors for a unique twist. CITYRWORA MAY 31 2012 PERMIT CENTER M12�0�2 FRONT VIEW SIDE VIEW AIR INLET AIR COOLED MODELS AIR OUTLET r AIR OUTLET POWER CONNECTION REAR VIEW Continuous research leads to ongoing product improvements; therefore, these specifications are subject to change without notice and should not be used as installation specifications. Distributed by: �J STOELTING' FOODSERVICE EQUIPMENT 502 Highway 67 • Kiel, WI 53042 -1600 920 - 894 - 2293.800- 558 -5807 Fax: 920-894-7029 E -mail: foodservice @stoelting.com www.stoeltingfoodservice.com ISO 9001:2008 Registered Certified, Listed and /or Recognized by: C LISTED US Model F231. Dimensions width height depth Machine as shipped 19 -1/4" (48,9 cm) 32" (81,3 cm) 58 -1/4" (148,0 cm) 60" (152,4 cm) 28" (71,1 cm) 39" (99,1 cm) Weight 400 Ibs (181,4 kg) 470 Ibs (213,1 kg) Electrical running amps connection type 1 Phase, 208 -240 VAC, 60Hz 12A NEMA 6 -20P power cord provided 3 Phase, 208 -240 VAC, 60Hz 10A NEMA L15 -20P power cord provided International Option 1 Phase, 220 -240 VAC, 50Hz Compressor 12,000 Btu /hr (R -404A) Drive Motor Two - 3/4 hp Air Flow Air cooled units require 3" (7,6 cm) air space on both sides Plumbing Fittings Water cooled units require 1/2" N.P.T. water and drain fittings. Maximum water pressure of 130 psi. Minimum water flow rate of 3 GPM. Ideal EWT of 50 ° -70 °F Hopper Volume Two - 3 gallon (11,35 liters) Freezing Cylinder Volume Two - 0.85 gallon (3,22 liters) Continuous research leads to ongoing product improvements; therefore, these specifications are subject to change without notice and should not be used as installation specifications. Distributed by: �J STOELTING' FOODSERVICE EQUIPMENT 502 Highway 67 • Kiel, WI 53042 -1600 920 - 894 - 2293.800- 558 -5807 Fax: 920-894-7029 E -mail: foodservice @stoelting.com www.stoeltingfoodservice.com ISO 9001:2008 Registered Certified, Listed and /or Recognized by: C LISTED US Nor -Lake Model: NLUR27 Item #4 SPECIFICATIONS 1/20/2012 ITEM# 4 - REFRIGERATED COUNTER, WORK TOP (1 REQ'D) Nor -Lake NLUR27 AdvantEDGETM Undercounter /Worktable Refrigerator, 27 -1/2" W, (1) self - closing door, auto defrost, magnetic gaskets, (2) vinyl coated shelves, temperature range 32° to 40 °F, stainless steel interior, top, front & ends, 4" casters, 1/5 hp, 115v/60/1, 3.2amps, cord, NEMA 5 -15P, UL, C -UL, ETL Sanitation, EnergyStar© rated ELECTRICAL VOLTS CYCLE (HZ) PHASE CONN AFF NEMA AMPS KW HP MCA MOCP 115 60 1 5 -1SP 3.2 1/5 Standard TCBY - 2012 Concept Services REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2012 City of Tukwila BUILDING DIVISION crtri�t� MAY 31 2012 PERMIT CENTER EOST Page 4 Nor -Lake NUK -UAKt, INUUKtUKAI t 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 8UU -955 -5253 715- 386 -2323 800 - 966 -5253 Parts 800 - 388 -5253 Service 715 - 386 -6149 FAX www.norlake.com NLUR27 Item #:4 NORIAKE AdvantEDGE Undercounter/Worktable .Refrigerators PROJECT: ITEM NUMBER: MODEL NUMBER: SPECIFICATIONS FOR: NLUR27, NLUR48, NLUR60, NLUR72 • Finish: Stainless steel interior and exterior. • Insulation: The complete cabinet and doors are foamed -in -place with polyurethane insulation. • Hardware: Recessed pocket pull handle with two vinyl coated shelves per door, 61/ diameter casters standard. • Elec rical: 115 volt, 60 Hz, 1 phase with cord and plug. • Refrigeration: Self contained forced air refrigeration system. The condensate is collected and automatically evaporated from an energy efficient air over wick style vaporizer. Refrigerant flow is controlled by a capillary tube. R -134a refrigerant. Temperature range: 32 °F to 40 °F. • Approvals; UL, C -UL and ETL Sanitation. STANDARD FEATURES • Air cooled condensing unit • Automatic condensate vaporizer • Automatic defrost • Capillary tube system • Casters standard • Magnetic gaskets • Recessed pocket pull handles • Self closing doors • Stainless steel interior and exterior • UL, C -UL and ETL sanitation ■ Vinyl coated shelves • Warranties: 1 Year Parts & Labor, 5 Year Compressor OPTIONAL FEATURES* ■ Additional shelves ■ Low profile casters Nor -Lake, Inc.. Registered to ISO 9001:2008 File No. 10001816 'Most options are evadable one week from receipt of order. Please contact us for specific questions, "C -UL is Underwriters Laboratories Safely Certification Mark which indicates that UL has tested the equipment to applicable CSA Standarda, Standard TCBY - 2012 Concept Services E- 21.1d2:130 NJ3N 318d15.i210M2131N110a213aN(1 3ea3luen' { SPECIFICATION ptiinF Page: 5 NLUR27 Item #:4 • • • • • • • • • 0 • • O • • 0 • 0 0 • • • 0 • • • • • 4 a g 02 Nor -Lake F. 699 (27 t/2) 0000694;2: t14: FRONT TOP NLUR27 wort hoe (23 7/61 FRONT rr NLUR48 DOOR 761 [70) rr 227 [14 11Q TOP 1723 [ea 3/a1 FRONT TOP NLUR60 tea in WC OCOR GOO in 2A] FRONT TOP NLUR72 Standard TCBY - 2012 a a [ 762 (SDI SIDE SPECIFICATIONS Model NLUR27 NLUR48 NLUR60 NLUR72 Crated Height 36 -1/4" 36 -1/4" 36 -1/4" 36 -1/4" Crated lMdth 30 -1/8" 51 -1/8" 63" 74 -3/8" Crated Depth 33 -1/2" 33 -1/2" 33 -1/2" 33 -1/2" Crated Weight (Ibs.) 199 280 333 384 Interior Height 26 -1/8" 26 -1/8" 26-1/8" 26 -1/8" Interior Width 23 -3/4" 44 -5/8" 56 -3/4" 68 -5/8" Interior Depth 20 -1/4" 20 -1/4" 20 -1/4" 20 -1/4" Overall Height 35 -7/8" 35 -7/8" 35 -7/8" 35 -7 /8" Overall Width 27 -1/2" 48 -1/4" 60 -3/8" 72 -3 /8" Overall Depth 30" 30" 30" 30" Gross Cubage (ft.3) 7 13 16 20 Number of Shelves 2 4 4 6 Number of Casters 4 4 4 4 Condensing Unit Size 1/5 HP 3/8 HP 3/8 HP 3/8 HP Refrigerant R -134a R -134a R -134a R -134a Electrical Characteristics 115/60/1 115/60/1 115/60/1 115/60/1 Cord and Plug Furnished Yes Yes Yes Yes Nema Plug Configuration 5-15P 5 -15P 5 -15P 5 -15P Total Amp Draw 3.2 7.9 7.9 8.1 Specifications subject to change without notice. i %Standex Food Service Eouloment Group NORLAKE Revision: 5/10 ©2010 Nor -Lake, Inc. Printed in the USA Pori Nttmhar. 14AR97 Concept Services Page: 6 Randell Model: 9928SCA Item #5 SPECIFICATIONS 1/20/2012 ITEM# 5 - COLD FOOD PAN, DROP-1N (1 REQ'D) Randell 9928SCA Drop -In Cold Food Unit, refrigerated, 30,25 "L, 26 "W, 2 -pan size, Insulated pan, s/s inner liner & top, corrosion resistant steel exterior, swivel base condensing unit, 1/4 HP, NSF 7 ACCESSORIES IELECTRICAL Mfr Qty Model Spec Randell 1 115v/60/1 -ph, 5.0 amps, NEMA 5 -15P, standard VOLTS CYCLE (HZ) PHASE CONN AFF NEMA AMPS KW HP MCA MOCP 115 60 1 Cord & Plug 5 -15P 5 .575 1/4 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1'7 2012 City of Tukwila BUILDING DIVISION CITY MAY 31 2012 PERMIT CENTER M 12 -082 Standard TCBY - 2012 Concept Services Page 7 Randell 9928SCA Item #:5 RAN DELL® Drop -In Wrapped Coldwall Cold Pan models 99O0SCA/SCN model ❑ 9918SCA ❑ 9928SCA . 09943SCA 0 9957SCA ❑ 9946SCN ❑ 9966SCN ❑ 9987SCN Description: Self- contained, wrapped coldwall drop -in refrigerated cold display pan with one piece stainless steel Interior and top. Drain, and gate valve provided. R -404a refrigerant, "CFC free ". Wrapped refrig- eration construction with condensing unit, expansion valve, and thermostatic control. Cordset for 115V operation. Meets NSF Std. 117 for holding 41°F product temperatures. Specifications: Condensing unit mounted on a swivel platform that allows for 90 degrees of rotation of intake /exhaust louver, giving customer the option of mounting our louver on any of the counters four sides. Model 9918SCA is not available with rotating compressor housing. UNIT EXTERIOR: Top and coved corner interior to be constructed of 18 gauge stainless steel. Exterior body to be corrosion resistant steel. Condensing unit mounted on corrosion resistant framework, suspended below unit body. (1) stainless steel louver panel provided for field installation in counter. UNIT INTERIOR: Interior fitted with 1" drain at one end. Drain nipple supplied with gate valve. Insulated with CFC free, foamed In place polyurethane. Recessed, stainless steel ledge provided for supporting pans, adaptor bars Included on SCA units. REFRIGERATION: CFC free, R -404a refrigeration system to be wrapped refrigeration construction with thermostatic control for operator adj ustab II ity. Entire system mounted on corrosion resistant framework, suspended below unit body. 8' cordset (NEMA 5 -15P) supplied for 115V operation. Standard Features: • Swivel base condensing unit allows for unlimited location of the single air Intake /exhaust louver (model 9918SCA is not available with rotating compressor housing. • New Randell exclusive easy mount system • Self- contained, wrapped refrigeration system with thermostatic control, system utilizes "CFC free ", R -404a refrigerant • Meets 1998 NSF Std. #7 - holds 41 °F product temperatures • All stainless steel top and coved corner interior • Drain and gate valve provided • Foamed in place, "CFC free" urethane insulation • One dual air movement louver provided • 9' corset for 120V plug -in operation model 9986SCA shown �1 0 9972SCA 09986SCA model 9966SCN shown • Seff- contained, refrigerated unit for cold display without ice • Custom sizes available • Easy installation with sliding hood, louver and hold down brackets Options & Accessories: ❑ Adaptor bars ❑ Remote on /off switch 33'r to411 1055 Mendell Davis Drive, Jackson, MS 39272 888 - 994 -7636, unifiedbrands.net Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing our product line websites, ...:C...IL.....J. ..... t....L......... ....J..a..J .....d... ...i..................1 .n.- :fi......,... Standard TCBY - 2012 Concept Services Randell Drop -In, Page 1 PP SPEC0055 Rev. A Revised 06/06 Page: 8 .;# • Randell RANDELL. 9928SCA Item #:5 Models 9900SCA/SCN 17375' C 1__J 155' 5.- 175'+ CUTOUT DIMENSION 18'%24 5' r- 71 575' -1 ns' fOr 2425' -- 28 51000. 01X111141 r— 211175' 4.4.1 L,55'J r— 21.875' -+t 1011 I I A' 0 'i L155•J +� 24 25' ••■••• r■ 20 ■r WIUI10WFN9011 2418.42415' r. 21.875' e,5' n L,6 J �-- 7425- —m- (17811 DIAWN90N 41 075' 8 24 75' 40u6. 141121SCA 10 S. I.— 21 VS" •—.1 ti r--r 775' l 1. MODD.A717SG '�•• 15 1:7 - 7770117 11107.1111001 8775- %2475' M0741. 4 92.00.4 21475' -51 •+1 142857 f�•• nJ. t 275' a 11 1813+ CLiW/104A1147146 M1825. 4 24.75' 8;' CAW 111117111044 457417' 175. I y l J 1425' 4007 1114455611 44 4n MOM/ 110171.454775011 IAOTC 11.111111:11 Model 12 "x2011 Pan Capacity 0/A Dimension Length Width Cut Out Size Length Width H.P. Volts Amps NEMA Ship Wt. 9918SCA 1 171 /2" 26" 16" 24 3/4" 1/4 115/60/1 5 5 -15P 110 9928SCA 2 301 /4" 26" 28 3/4" 24 3/4" 1/4 115/60/1 5 5 -15P 140 9943SCA 3 43 3/8" 26" 41 7/8" 24 3/4" 1/4 115/60/1 5 5 -15P 175 9957SCA 4 561 /4" 26" 54 3/4" 24 3/4" 1/4 115/60/1 5 5 -15P 210 9972SCA 5 691 /4" 26" 67 3/4" 24 3/4" 1/4 115/60/1 5 5 -15P 245 9986SCA 6 821 /8" 26" 80 5/8" 24 3/4" 1/4 115/60/1 5 5 -15P 280 9946SCN 2 46" 18 5/16" 441 /2" 17" 1/4 115/60/1 5 5 -15P 140 9966SCN 3 66 3/4" 18 5/16" 65 7/16" 17" 1/4 9987SCN 4 871/2" 18 5/16" 86 3/16" 17" 1/4 115/60/1 5 115/60/1 5 5 -15P 175 5 -15P .210 055 Mendell Davis Drive, Jackson, MS 39272, 888 -994 -7636, unifiedbrands.net r U N I FI E D BRAN DS Information contained in this document is known to be current and accurate at the time '°°° " "° `" ,5w, I of printingkreation. Unified Brands recommends referencing our product line websites, ... 1:..J4.....J.....4 1... �L.........4 ....J..4.J .....J...4 :..1.......w.......J ......:lt.- 4:.. -. Standard TCBY - 2012 • Concept Services Component Page: 9 Server Products Model: 81290 Item #7B SPECIFICATIONS 1/20/2012 ITEM# 7B - FOOD WARMER, HOT FUDGE CARAMEL (1 REQ'D) Server Products 81290 TWIN FS /FSP TWIN FUDGE SERVER WITH PUMP & LADLE, stainless steel twin warmer Includes (1) each stainless steel pump and ladle, water -bath wells are controlled by individual adjustable thermostats for accurate heat control, accepts (2)3 quart (2.8 L) stainless steel jars (94009) or food manufacturer's #10 cans, pump yields 1 oz (30 ml) with collars provided to reduce yield in 1/8 oz (3.7 ml) increments, ladle is 10" (25.4 cm), 1 oz (30 ml), when dispensing potentially hazardous foods, a spout warmer is required, jars not included, (1000W/120V), NSF & C -UL -US LISTED ELECTRICAL VOLTS CYCLE (HZ) PHASE CONN AFF NEMA AMPS KW HP MCA MOCP 120 60 1 5 -15P 8.33 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2012 City of Tukwila BUILDING DIVISION CiTYRSASt6 MaY. 1 2012 HERMIT CENTER M 1 E (9//ft Standard TCBY - 2012 Concept Services Page 13 Server Products Date: Project: 81290 Item #:7B Models Twin FS /FSP FOOD WARMERS {HOT TOPPING} Twin Twin FS TWIN PUMP /LADLE r Twin FS /FSP 81290 'U Twin FS 81220 ALSO AVAILABLE FOR EXPORT us usreo Two Year Warranty Server Products equipment is backed by a two -year limited warranty against defects in materials and workmanship. For our complete warranty statement, please refer to server- products.com. Standard TCBY - 2012 Quantity: Item Number: Bid Description All stainless steel construction with a brushed ( #4) finish. Each dispenses directly from (2) stainless steel jars or #10 cans (not included). (2) adjustable precalibrated thermostats control individual 500 watt heating elements. Temperature settings— marked on thermo- stat knobs —range from 100° F (38° C) to 200° F (93° C). Power is controlled with (2) ON /OFF rocker switches. The Twin FS /FSP is designed to pump and ladle hot toppings. Comes complete with a lift -off lid and 1 ounce (30 mL) 10" (25.4 cm) Ladle (82561). The pump features a rugged cast valve body and welded construction. Maximurn stroke yields 1 ounce (30 mL). Gauging collars are supplied to reduce yield in '/8 ounce (3.7 mL) increments. The Twin FSP is designed to pump (2) hot toppings. The Twin FS is designed to ladle (2) hot toppings. Standard Features • All stainless steel construction for durability • Pump design prevents loss of valve balls • Water fill line eliminates overflow accidents • (2) 500W heating elements for reliable heating & holding • Adjustable precalibrated thermostats for accurate heat control • Temperature marks on knobs with protective knob guard • Dispense directly from stainless steel jars or #10 cans • Pump stroke yields 1 oz (30 ml), now adjustable in '/9 oz (3.7 ml) increments — allows for Portion Optimization ' • (2) cleaning brushes included with pumps for maintenance Accessory Items n 1 oz (30 mL) 10" (25.4 cm) Ladle 82561 3 qt (2.8 L) Stainless Steel Jar 94009 Specifications on reverse side Concept Services Page: 14 Server Products 81290 Item #:7B Models Twin FS /FSP 1 FOOD WARMERS {HOT TOPPING} Twin Twin FS TWIN PUMP /LADLE Twin Fudge Server with Pump and Ladle 1 155/66 38.9 cm 12s /e 31.3 cm 17" 43.2 cm Specifications Construction Brushed (//4) stainless steel units. Pumps feature a rugged cast valve body and welded construction. Capacity (2) stainless steel jars or #10 cans hold 3 quarts (2.8 L) each; 6 quart (5.7 L) total. Models Twin FS /FSP 81290 Twin FSP 8123/0 Twin FS 81220** Height in 155 /G 1 5 5/,h 1 2 5 /I6 cm 38.9 38.9 31.3 Width in 17 17 17 cm 43.2 43.2 43.2 Depth in 13 1/2 13 1/2 13 1/2 cm 34.3 34.3 34.3 Dim. A in cm 4 3/4 12.1 4 3/4 12.1 N/A Weight lb 18 19 17 kg 8.2 8.6 78 Electrical 120V, 60Hz, 1000W, 8.3A 72 in (183 cm) cord set NEMA 5 -15P, 15A, 120V PLUG FOB Richfield, Wisconsin 53076 NSF listed as a rethermalization unit to ensure food is quickly heated to a safe temperature before bacteria has an opportunity to grow. v CAD Library Individual CAD images can be downloaded from our website. We are also a member of The KCI. CADalog with more than 100 . other manufacturers. Our complete collection of CAD files can be purchased through Kochman Consultants, Ltd. at kcicad.com. Server Products, Inc. • P.O. Box 98 • Richfield, WI 53076 • Toll Free: 800 -558 -8722 P: 262-628-5600 • r: 262- 628 -51 10 • spsales©server- products.com • server - products.com Srtve Prcduris. Inc rewrven the ri9hi n mndiy spn bccoons without chUOnann. Pr•nled m I1■A S-2011 S■xk # 0205 ' Standard TCBY - 2012 Concept Services Page: 15 Server Products Model: 81230 Item #7A SPECIFICATIONS 1/20/2012 ITEM# 7A - FOOD WARMER, HOT FUDGE CARAMEL (1 REQ'D) Server Products 81230 TWIN FSP TWIN FUDGE SERVER WITH PUMPS, stainless steel twin warmer includes (2) stainless steel pumps, pumps yield 1 oz (30 ml) with collars provided to reduce yield in 1/8 oz (3.7 ml) increments, water -bath wells are controlled by individual adjustable thermostats for accurate heat control, accepts (2) 3 quart (2.8 L) stainless steel jars (94009) or food manufacturer's #10 cans, when dispensing potentially hazardous foods, a spout warmer is required, jars not included, (1000W /120V), NSF & C -UL- US LISTED IELECTRICAL VOLTS CYCLE (HZ) PHASE CONN AFF NEMA AMPS KW HP MCA MOCP 120 60 1 5-1SP 8.33 1 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2012 City of Tukwila BUILDING DIVISION M Standard TCBY - 2012 Concept Services cxrvu MAY 31 2012 PERMIT CENTER Page 10 Server Products 81230 Date: Project: Item #:7A Models Twin FS /FSP Twin FSP Twin FS FOOD WARMERS {HOT TOPPING} TWIN PUMP /LADLE Twin FS /FSP 81290 Twin FS 81220 US LISTED ALSO AVAILABLE FOR EXPORT Warranty Server Products equipment is backed by a two -year limited warranty against defects in materials and workmanship. For our complete warranty statement, please refer to server - products.com. Standard TCBY - 2012 Quantity: Item Number: Bid Description All stainless steel construction with a brushed ( #4) finish. Each dispenses directly from (2) stainless steel jars or #10 cans (not included). (2) adjustable precalibrated thermostats control individual 500 watt heating elements. Temperature settings— marked on thermostat knobs - -range from 100° F (38° C) to 200° F (93° C). Power is controlled with (2) ON /OFF rocker switches. The Twin FS /FSP is designed to pump and ladle hot toppings. Comes complete with a lift -off lid and 1 ounce (30 mL) 10" (25.4 cm) Ladle (82561). The pump features a rugged cast valve body and welded construction. Maximum stroke yields 1 ounce (30 mL). Gauging collars are supplied to reduce yield in ' /s ounce (3.7 mL) increments. The Twin FSP is designed to pump (2) hot toppings. The Twin FS is designed to ladle (2) hot toppings. Standard Features All stainless steel construction for durability Pump design prevents loss of valve balls Water fill line eliminates overflow accidents (2) 500 watt heating elements for reliable heating and holding Adjustable precalibrated thermostats for accurate heat control Temperature marks on knobs with protective knob guard Dispense directly from stainless steel jars or # 10 cans Pump stroke yields 1 ounce (30 mL), now adjustable in '/s ounce (3.7 mL) increments — allows for Portion Optimization' (2) cleaning brushes included with pumps for maintenance Topping Equipment Accessories ❑ 1 oz (30 mL) 10" (25.4 cm) Ladle 82561 ❑ 3 qt (2.8 L) Stainless Steel Jar 94009 Specifications on reverse side Concept Services Page: 11 Server Products 81230 Item #:7A Models Twin FS /FSP FOOD WARMERS {HOT TOPPING} TM::: TWIN PUMP /LADLE Twin Fudge Server with Pump and Ladle 13 1/2 34.3 cm "—Dim. A 29.1 cm 9 11/16 24.6 cm SERVER 43.2 cm Specifications Construction Capacity Brushed ( #4) stainless steel units. Pump! feature a rugged cast valve body and welded construction. (2) stainless steel jars or #10 cans hold 3 quarts (2.8 L) each; 6 quart (5.7 L) tot Models Twin FS /FSP Twin FSP Twin FS 81290 81230 812201 Height in 155/16 155 /16 125/16 cm 38.9 38.9 31.3 Width in 17 17 17 cm 43.2 43.2 43.2 Depth in 1 31/2 131/2 911/16 cm 34,3 34.3 24.6 Dim.A in 43/4 43/4 N /A- cm 12.1 12.1 Weight 181b 191b 171b -- ---- - - -_ .__ -8.2 kg 8.6 kg - - -- __ -7.8 kq- Electrical 120V, 60Hz, 1000W, 8.3A 72 in (183 cm) cord set { NEMA 5 -15P 15A. 120V PLUG FOB Richfield, Wisconsin 53076 al. NSF Listed as a rethermalization unit to ensure food is quickly heated to a safe temperature before bacteria has an opportunity to grow. tr CAD Library Individual CAD images can be downloaded from product pages on our web site. We are also a member of The KCL CADalog with more than 100 other manufacturers. Our complete collection of CAD files can be purchased through Kochman Consultants, Ltd. at kcicad.com. Server Products, Inc. • P.O. Box 98 • Richfield, WI 530/6 • Toll Free: 800-558-8722 P: 262- 628-5600 • F: 262-628 -51 10 • spsales@server- products.comn • server - products.com Serve. Pr iuri•., Inr .av■e, rho nghi m rn. iki s^+r;Frryknn.. wth- no,Higroion Pnr.erl .n 1!SA 9 2009/ M Sc irk 02051 Standard TCBY - 2012 Concept Services Page: 12 Metro Model: VARIES Item #9 SPECIFICATIONS 1/20/2012 ITEM# 9 - SHELVING, WIRE (1. REQ'D) Metro VARIES Super Erecta® Shelf, wire, sizes varyl, chrome - plated finish, plastic split sleeves are included in each carton ACCESSORIES Mfr Qty Model Spec Metro Standard TCBY - 2012 1 VARIES Super Erects® Post, sizes vary, for use with stem casters, chrome plated finish REVIEWED FOIE CODE COMPLIANCE APPROVED JUL 17 2012 City of Tukwila BUILDING DIVISION crTY OF TUK'NL► h!A1 31 2012 PERMIT Cow Concept Services Page 16 Metro VARIES Item #:9 Item ti Job SUPER ERECTA SHELF® WIRE SHELVING • Unique Design: The open wire design of these shelves minimizes dust accumulation and allows free circulation of air, greater visibility of stored items and greater light penetration. • Durable Construction: Super Erecta shelves and posts are constructed of heavy -gauge carbon steel or Type 304 stainless steel. • Choice of Finishes: Super Erecta Brite'" and chrome - plated for dry storage; Metroseal 3' " with Microban® antimicrobial product protection and stainless steel for corrosive environments; and attractive epoxy color options for merchandising applications. • Versatile: Super Erecta Shelf° wire shelving can adapt to your changing needs. By using various accessories, hundreds of shelving configurations become possible. • Fast, Secure Assembly: SiteSelect- Posts have a double groove visual guide feature every 8" (203mm), circular grooves at 1" (25mm) increments, and are numbered at 2" (50mm) intervals. A patented, tapered split sleeve snaps together around each post. Tapered openings in the shelf corners slide over the tapered split sleeves providing a positive lock. Shelf is assembled in minutes without the use of any special tools. • Adjustability: Shelves can be adjusted at 1" (25mm) intervals along the entire length of the post. • Shelf Ribs: Run front to back, allowing you to slide items on and off shelves smoothly. • Shelf Accessibility: Shelves can be loaded /unloaded easily from all sides This open construction allows maximum use of storage cube. • Adjustable Feet: Bolt levelers compensate for surface irregularities. Note: Stainless stationary posts are equipped with stainless steel leveling feet. 'MICROBAN° and the MICROBAN' symbol are registered trademarks of the Microban Products Company, Huntersville, NC. Standard TCBY - 2012 InterMetro Industries Corporation North Washington Street Wilkes- Barre, PA 18705 www.metro.com Concept Services EMERSON.. Page: 17 Metro VARIES Item #:9 SUPER ERECTA SHELF® WIRE SHELVING Wire Shelves Spilt Sleeve Aluminum Split Sleeve • Metroseal 3: Metro's proprietary epoxy coating contains Microban® antimicrobial product protection. Microban antimicrobial protects the epoxy coating from bacteria, mold, mildew, and fungus that cause odors, stains, and product degradation. • See spec sheet 10.14 for epoxy color options. • Plastic split sleeves are included with each shelf Replacements are available: Cat. No. 9985 (bag of 4) • Aluminum split sleeves are recommended for abusive mobile applications and autoclave applications. Cat. No. 9986Z (bag of 4 with zinc C- rings) Cat. No. 9986S (bag of 4 with stainless steel C- rings) • Load capacity (evenly distributed) per shelf Depths: 14" to 24" (355 to 610mm) 800 lbs. (363kg) for lengths of 18" to 48" (457 to 1219mm) 600 lbs. (272kg) for lengths of 54" (1370mm) or longer • Load capacity (evenly distributed) per unit. Stationary shelving units have a maximum load capacity (evenly distributed) of 2,000 lbs. (907kg) Mobile units have a maximum capacity of three times the caster load rating up to but not exceeding 1,000 lbs. (453kg) total. Consult the Metro catalog for caster load ratings • SUPER ERECTA SHELF meets Government Specifications MIL- S- 40144E. Approx Model No Model No Model No Model No Nominal Width/Length Pkd Wt. Super Erecte Brite Chrome Metroseal 3 with Microbarr• Stainless (in) (mm) (lbs 1 (kg) 1424BR 1424NC 1424NK3 1424NS 14x24 355x610 6 2.7 1430 BR 1430NC 1430NK3 1430NS 14x30 355x760 7 3.2 1436BR 1436NC 1436NK3 1436NS 14x36 355x914 8 3.6 1442BR 1442NC 1442NK3 1442NS 14x42 355x1066 9V2 4.3 1448BR 1448NC 1448NK3 1448NS 14x48 355x1219 10'12 4.7 14601319 1460NC 1460NK3 1460NS 14x60 355x1524. 14 6.3 1472BR 1472NC 1472NK3 1472NS 14x72 355x1829 17 7.7 1824BR 1824NC 1824NK3 1824NS 18x24 457x610 7 3.2 1830319 1830NC 1830NK3 1830N3 18x30 457x760 8 3.6 1836BR 1836NC 1836NK3 1836NS 18x36 457x914 9112 4.3 1842619 1842NC 1842NK3 1842NS 18x42 457x1066 11 5.0 1848BR 1848NC 1848NK3 1848NS 18x48 457x1219 12 5.4 1854BR 1854NC 1854NK3 1854NS 18x54 457x1370 14112 6.6 1860BR 1860NC 1860NK3 1860NS 18x60 457x1524 17 7.7 1872819 1872NC 1872NK3 1872NS 18x72 457x1829 20 9.1 21248R 2124NC 2124NK3 2124NS 21x24 530x610 8 3.6 21301319 2130NC 2130NK3 2130NS 21x30 530x760 9 4.1 2136819 2136NC 2136NK3 2136NS 21x36 530x914 11 5.0 21428R 2142NC 2142NK3 2142NS 21x42 530x1066 12 5.4 2148BR 2148NC 2148NK3 2148NS 21x48 530x1219 14 6.4 2154BR 2154NC 2154NK3 2154NS 21x54 530x1370 16 7.3 2160BR 2160NC 2160NK3 2160NS 21x60 530x1524 18 8.2 2172BR 2172NC 2172NK3 2172NS 21x72 530x1829 24 10.9 2424BR 2424NC 2424NK3 2424NS 24x24 610x610 9 4.1 2430BR 2430NC 2430NK3 2430NS 24x30 610x760 11 5.0 2436BR 2436NC • 2436NK3 2436NS 24x36 610x914 13 5.9 2442BR 2442NC 2442NK3 2442NS 24x42 610x1066 15 6.8 2448BR 2448NC 2448NK3 2448NS 24x48 610x1219 16 7.3 2454BR 2454NC 2454NK3 2454NS 24x54 610x1370 19 8.6 2460BR 2460NC 2460NK3 2460NS 24x60 610x1524 21 9.5 2472819 2472NC 2472NK3 2472NS 24x72 610x1829 26 11.8 Note: 14" (355mm) deep units Free- slandnrg units: Foot plates should be used and secured to the floor, Mobile units: maximum allowable post height is 54" (1370mm) Standard TCBY - 2012 Concept Services Page: 18 Metro VARIES Item #:9 SUPER ERECTA SHELF® WIRE SHELVING SiteSelectTM Posts Stationary Posts Stationary posts are equipped with a leveling bolt to account for uneven floors. • Height includes leveling bolt (completely tightened) and post cap Leveling bolt can be adjusted V?' (13mm). • Foot plates may be ordered separately and installed in place of leveling foot. • Replacement leveling bolts Zinc Cat. No. RPF04 -004 Stainless Steel Cat. No. RPF04 -004C • Replacement post cap for standard posts Black Cat. No. RPC06 -035 Model No, Approx. Model No Metrosoel 3 Model No Height Pkd, Wt Chrome with Microban Stainless Steel (in) (mm) (tbs) (kg) 7P 73/e 167 1/2 0.3 13P 13PK3 13PS 143le 365 1 0.5 27P 27P5 283/A 720 13/4 0.75 33P 33PK3 33PS 343/a 873 2 0.9 54P 54PK3 54PS ' 1382 3 1.4 63P 63PK3 63PS 627/1e 1585 3' /x 1.6 74P 74PK3 74P5 74'/2 1892 4 1.8 86P 86PK3 86PS 861/2 2197 5 2.3 *96P 961/2 2450 51/2 2.5 '96P should not be used on units less than 24' (610mm) deep, Consult Metro Engineering for alternate recommendations. Mobile Posts (For use with Stem Casters) • Height includes post cap. Model No Model No Melroseal 3 Model No 'Height Chrome with Microban Stainless Steel (in ) (mm) 27UP 27UPS 273/4 704 33UP 33UPK3 33UPS 333/4 857 54UP 54UPK3 54UPS 5313/1e 1366 63UP 63UPK3 63UPS 61t3/r0 1570 70UPK3 693/4 1771 74UP 74UPK3 74UPS 73'/% 1876 86UP 86UPK3 86UPS 85' /e 2181 Approx. Pkd. Wt, (los) (kg) 13/4 0.75 2 3 31/2 33/4 4 41/2 0.9 1.4 1.6 1.7 1.8 2.0 Staked Posts (For use with Truck Dollies) • Each post connects to the truck dolly through the stem receptacle. The stem receptacle is staked into the bottom of the post to ensure a durable connection in abusive mobile applications. • Each includes a leveling /connecting bolt. Model No. Chrome 54P -STKD 63P -STKD 74P -STKD Model No. Stainless Steel 54PS-STKD 63PS -STKD 74PS -STKD Height (in,) (min) 547/te 1382 627/1a 1585 741/2 1892 Approx Pkd, WI. (Ibs,) (kg) 3 1.4 3'/2 1.6 4 1.8 Swedged Posts (For use with Stem Casters in Cart Wash Applications) • Each post has an aluminum cap swedged into the top of the post. Model No. Stainless Steel 33UPS -SW .54UPS-SW 63UPS-SW Height (in ) (rnrn) 33314 857 5313/r6 1366 61'311e 1570 Approx Pkd WI (Iba ) (kg) 2 0.9 3 1.4 31/2 1.6 Standard TCBY - 2012 Concept Services SlteSelect Posts feature double grooves every 8" (203mm) to aid assembly. Special Length Posts Special length cut posts are available. Consult your Metro representative for more information. Page: 19 Metro VARIES Item #:9 Job SUPER ERECTA SHELF® WIRE SHELVING Super Wide Shelving • High - density Storage: Super Wide' shelves have a greater storage area for holding large quantities of supplies, especially large, bulky objects, providing maximum storage in minimum space. • Load Capacity (evenly distributed) per shelf: Depths: 30" and 36" (760 and 914mm) 600 lbs. (272kg) for lengths 48" (1219mm) or shorter. 400 lbs. (181kg) for lengths 54" (1370mm) or longer. Model No. Approx. Model No Melroseal 3 Model No. Nominal Width/Length Pkd. Wt Chrome with Microban Stainless Steel (in.) (mm) (lbs.) (kg) 3036NC 3036NK3 3036NS 30x36 760x914 15 6.8 3048NC 3048NK3 3048NS 30x48 760x1219 21 9.5 3060NC 3060NK3 3060NS • 30x60 760x1524 26V7 11.8 3072NC 3072NK3 3072NS 30x72 760x1829 31 14.0 3636NC 3636NK3 3636NS 36x36 910x914 18 8.2 3648NC 3648NK3 3648NS 36x48 910x1219 23 10.4 3660NC 3660NK3 3660NS 36x60 910x1524 29 13.1 3672NC 3672NK3 3672NS 36x72 910x1829 341/2 15.4 Foot Plates • Use to bolt units to the floor, or when a broader, more stable foot is desired. Foot plates also help to protect floors by distributing the point load of the shelving unit across a larger contact point. • Foot plates (completely tightened) add ' /e" (3mm) to the specified heights of each stationary post on the table. Zinc Cat. No. 9993Z Stainless Steel Cat. No. 9993S "S " Hook • Used to add on shelving units with only two posts required. Order two per shelf level. Cat. No. 9995Z All Metro Catalog Sheets are available on our Web Site: www.metro.com InterMetro Industries Corporation North Washington Street, Wilkes- Barre, PA 18705 Phone: 570 - 825 -2741 Fax: 570-825-2852 For Product Information: • Latin America: 1.561.333.3824 U.S. and Canada: 1.800.433.2232 Europe: +31.76.587.7550 Standard TCBY - 2012 Concept Services L02-006 Printed in U.S.A. Rev 11 /08 Information and specifications are subject to change without notice. Please confirm at time of order. Copyright ® 2008 InterMetro Industries Corp. Asia /Pacific: +65.6567.8003 Middle East /Africa: +971.4.811.8286 Page: 20 Metro Model: VARIES Item #10/11 SPECIFICATIONS 1/20/2012 ITEM# 10/11- SHELVING, WIRE (1 REQ')) Metro VARIES Super Erecta® Shelf, wire, sizes vary, plastic split sleeves are Included in each carton, Metroseal 3 epoxy coated corrosion - resistant finish with Microban® antimicrobial protection, NSF ACCESSORIES Mfr Qty Model Spec Metro Standard TCBY - 2012 1 VARIES Super Erecta° SiteSelect'" Post, sizes vary, adjustable leveling bolt, posts are grooved at 1" increments and numbered at 2" increments, double grooved every 8 ", Metroseal 3 epoxy coated corrosion- resistant finish with Microban° antimicrobial protection REVIEWED FOR CODE COMPLIANCE APPROVED JUL 117 2012 City of Tukwila BUILDING DIVISION CITY OF TUKrnu► MAY 31 2012 PERMIT CENTER MI2OSZ Concept Services Page 21 Metro VARIES Item #:10/11 Item # Job SUPER ERECTA SHELF® WIRE SHELVING • Unique Design: The open wire design of these shelves minimizes dust accumulation and allows free circulation of air, greater visibility of stored items and greater light penetration. • Durable Construction: Super Erecta shelves and posts are constructed of heavy -gauge carbon steel or Type 304 stainless steel. • Choice of Finishes: Super Erecta Brite'" and chrome-- plated for dry storage; Metroseal 3' with Microban® antimicrobial product protection and stainless steel for corrosive environments; and attractive epoxy color options for merchandising applications. • Versatile: Super Erecta Shelf® wire shelving can adapt to your changing needs. By using various accessories, hundreds of shelving configurations become possible. • Fast, Secure Assembly: SiteSelect- Posts have a double groove visual guide feature every 8" (203mm), circular grooves at 1" (25mm) increments, and are numbered at 2" (50mm) intervals. A patented, tapered split sleeve snaps together around each post. Tapered openings in the shelf corners slide over the tapered split sleeves providing a positive lock. Shelf is assembled in minutes without the use of any special tools. • Adjustability: Shelves can be adjusted at 1" (25mm) intervals along the entire length of the post. • Shelf Rlbs: Run front to back, allowing you to slide items on and off shelves smoothly. • Shelf Accessibility: Shelves can be loaded /unloaded easily from all sides This open construction allows maximum use of storage cube. • Adjustable Feet: Bolt levelers compensate for surface irregularities. Note: Stainless stationary posts are equipped with stainless steel leveling feet. 'MICROBAN'a and the MICROBAN.' symbol are registered trademarks of the Microban Products Company, Huntersville, NC. Standard TCBY - 2012 InterMetro Industries Corporation North Washington Street Wilkes- Barre, PA 18705 www.metro.com EMERSON.. Concept Services Page: 22 Metro VARIES Item #:10/11 SUPER ERECTA SHELF® WIRE SHELVING Wire Shelves Split Sleeve Aluminum Split Sleeve • Metroseal 3: Metro's proprietary epoxy coating contains Microban® antimicrobial product protection. Microban antimicrobial protects the epoxy coating from bacteria, mold, mildew, and fungus that cause odors, stains, and product degradation. • See spec sheet 10.14 for epoxy color options. • Plastic split sleeves are included with each shelf Replacements are available: Cat. No. 9985 (bag of 4) • Aluminum split sleeves are recommended for abusive mobile applications and autoclave applications. Cat. No. 9986Z (bag of 4 with zinc C- rings) Cat. No. 9986S (bag of 4 with stainless steel C- rings) • Load capacity (evenly distributed) per shelf Depths: 14" to 24" (355 to 610mm) 800 lbs. (363kg) for lengths of 18" to 48° (457 to 1219mm) 600 lbs. (272kg) for lengths of 54" (1370mm) or longer • Load capacity (evenly distributed) per unit. Stationary shelving units have a maximum Toad capacity (evenly distributed) of 2,000 lbs. (907kg) Mobile units have a maximum capacity of three times the caster Toad rating up to but not exceeding 1,000 lbs. (453kg) total. Consult the Metro catalog for caster load ratings • SUPER ERECTA SHELF meets Government Specifications MIL- S- 40144E. Approx Model No Model No Model No Model No Nominal Width/Length Pkd. Wt Super Erects Brito Chrome Metroseal 3 with Microbarr` Stainless (in) (mm) (lbs) (kg) 1424BR 1424NC 1424NK3. 1424NS 14x24 355x610 6 2.7 1430 BR 1430NC 1430NK3 1430NS 14x30 355x760 7 3.2 1436BR 1436NC 1436NK3 1436NS 14x36 355x914 8 3.6 14428R 1442NC 1442NK3 1442NS 14x42 355x1066 9'/2 4.3 1448BR 1448NC 1448NK3 1448NS 14x48 355x1219 10V2 4.7 1460BR 1460NC 1460NK3 1460NS 14x60 355x1524 14 6.3 1472BR 1472NC 1472NK3 1472NS 14x72 355x1829 17 7.7 1824BR 1824NC 1824NK3 I824NS 18x24 457x610 7 3.2 1830BR 1830NC 1830NK3 1830NS 18x30 457x760 8 3.6 1836BR 1836NC 1836NK3 1836NS 18x36 457x914 9'/2 4.3 1842BR 1842NC 1842NK3 1842NS 18x42 457x1066 11 5.0 1848BR 1848NC 1848NK3 1848NS 18x48 457x1219 12 5.4 1854BR 1854NC 1854NK3 1854NS 18x54 457x1370 141/2 6.6 1860BR 1860NC 1860NK3 1860NS 18x60 457x1524 17 7.7 1872BR 1872NC 1872NK3 1872NS 18x72 457x1829 20 9.1 2124BR 2124NC 2124NK3 2124NS 21x24 530x610 8 3.6 213013R 2130NC 2130NK3 2130NS 21x30 530x760 9 4.1 2136BR 2136NC 2136NK3 2136NS 21x36 530x914 11. 5.0 2142BR 2142NC 2142NK3 2142NS 21x42 530x1066 12 5.4 214813R 2148NC 2148NK3 2148NS 21x48 530x1219 14 '6.4 2154BR 2154NC 2154NK3 2154NS 21x54 530x1370 16 7.3 2160BR 2160NC 2160NK3 2160NS 21x60 530x1524 18 8.2 2172BR 2172NC 2172NK3 2172NS 21x72 530x1829 24 10.9 2424BR 2424NC 2424NK3 2424NS 24x24 610x610 9 4.1 2430BR 2430NC 2430NK3 2430NS 24x30 610x760 11 5.0 2436BR 2436NC 2436NK3 2436NS 24x36 610x914 13 5.9 2442BR 2442NC 2442NK3 2442NS 24x42 610x1066 15 6.8 2448BR 2448NC 2448NK3 2448NS 24x48 610x1219 16 7.3 2454BR 2454NC 2454NK3 2454NS 24x54 610x1370 19 8.6 2460BR 2460NC 2460NK3 2460% 24x60 610x1524 21 9.5 2472BR 2472NC 2472NK3 2472NS 24x72 610x1829 26 11.8 Note: 14" (355mm) deep units. Free- standing units: Foot plates should be used and secured to the floor, Mobile units: maximum allowable post height is 54" (1370mm) Standard TCBY - 2012 Concept Services Page: 23 Metro VARIES Item #:10/11 SUPER ERECTA SHELF° WIRE SHELVING SiteSelectTM Posts Stationary Posts Stationary posts are equipped with a leveling bolt to account for uneven floors. • Height includes leveling bolt (completely tightened) and post cap Leveling bolt can be adjusted ' /V' (13mm). • Foot plates may be ordered separately and installed in place of leveling foot. • Replacement leveling bolts Zinc Cat. No. RPF04 -004 Stainless Steel Cat. No. RPF04 -004C • Replacement post cap for standard posts Black Cat. No. RPC06 -035 Model No. Chrome 7P 13P 27P 33P 54P 63P 74P 86P •96P Model No, Melroseal 3 with Microban Model No Stainless Steel 13PK3 13PS 27PS 33PK3 33PS 54PK3 54PS 63PK3 63PS 74PK3 74PS 86PK3 86PS Height (in.) (mm) 73/8 187 14418 365 28'18 720 343/* 873 54'/m 1382 62'18 1585 741/., 1892 86'1e 2197 96'12 2450 Approx. Pled WI (lea,) (kg) '/2 0.3 1 0.5 13/4 0.75 2 0.9 3 1.4 3'/2 1.6 4 1.8 5 2.3 5'h 2.5 '96P should not be used on units less than 24' (6lOrrrn) deep Consult Metro Enginoe'ing for deenate recommendations Mobile Posts (For use with Stem Casters) • Height includes post cap. Model No Melroseal 3 with Mirmban Model No Chrome 27UP 3311P 54UP 63UP 33UPK3 54UPK3 63UPK3 70UPK3 Model No Stainless Steel 27UPS 33UPS 54UPS 63UPS 74UP 74UPK3 86UP 86UPK3 74UPS 86UPS Height (in) (mm) 273/4 704 331/4 857 53' /“. 1366 61i3/16 1570 691/4 1771 73'/4 1876 85' /a 2181 Approx. Pad. WI. (Ihs) (kg) 11/1 0.75 2 09 3 1,4 312 1.6 33/4 1.7 4 1.8 4'/2 2.0 Staked Posts (For use with Truck Dollies) • Each post connects to the truck dolly through the stem receptacle. The stem receptacle is staked into the bottom of the post to ensure a durable connection in abusive mobile applications. • Each includes a leveling /connecting bolt. Model No Civumu 54P -STKD 63P -STKD 74P -STKD Model No Staloft'so Step( 54PS•STKD 63PS -STKD 74PS -STKD Fleighl 54' /m 1382_ 62' /re 1585 74'/2 1892 Approx Pled WI (11-Is 1 (k7) 3 1.4 3'/2 1.6 4 1.8 Swedged Posts (For use with Stem Casters in Cart Wash Applications) • Each post has an aluminum cap swedged into the top of the post. Model No Stainless Steel 33UPS -SW 54UPS -SW 63UPS -SW Height (in.) (mm) 333/4 857 531318 1366 6113/18 1570 Approx Pled WI Ohs ) (kg) 2 0.9 3 ' 1.4 3'/2 1.6 Standard TCBY - 2012 Concept Services SlteSelect Posts feature double grooves every 8" (203mm) to aid assembly. Special Length Posts Special length cut posts are available. Consult your Metro representative for more information. Page: 24 an H fig Metro VARIES Item#:10111 Jab SUPER ERECTA SHELF° WIRE SHELVING. Super Wide Shelving • High- density Storage: Super Wide`" shelves have a greater storage area for holding large quantities of supplies, especially large, bulky objects, providing maximum storage in minimum space. • Load Capacity (evenly distributed) per shelf: Depths: 30" and 36" (760 and 914mm) 600 lbs. (272kg) for lengths 48" (1219mm) or shorter. 400 lbs. (181kg) for lengths 54" (1370mm) or longer. Model No Model No Metroseal 3 Model No Chrome with Microban Stainless Steal 3036NC 3036NK3 3036NS 3048NC 3048NK3 3048NS 3060NC 3060NK3 3060NS 3072NC 3072NK3 3072NS 3636NC 3636NK3 3636NS 3648NC 3648NK3 3648NS 3660NC 3660NK3 3660NS 3672NC 3672NK3 3672NS Nominal Width/Length (in) (mm) 30x36 30x48 30x60 30x72 36x36 36x48 36x60 36x72 760x914 760x1219 760x1524 760x1829 910x914 910x1219 910x1524 910x1829 Approx Pkd. Wt (Ibs) (kg) 15 6.8 21 9.5 261/2 11.8 31 14.0 18 8.2 23 10.4 29 13.1 34r /r 15.4 Foot Plates • Use to bolt units to the floor, or when a broader, more stable foot is desired. Foot plates also help to protect floors by distributing the point load of the shelving unit across a larger contact point. • Foot plates (completely tightened) add 1 /8" (3mm) to the specified heights of each stationary post on the table. Zinc Cat. No. 9993Z Stainless Steel Cat. No. 9993S "S" Hook • Used to add on shelving units with only two posts required. Order two per shelf level. Cat. No. 9995Z All Metro Catalog Sheets are available on our Web Site: www.metro.com InterMetro Industries Corporation North Washington Street, Wilkes- Barre, PA 18705 Phone: 570 - 825 -2741 Fax: 570-825-2852 For Product Information: U.S. and Canada: 1.800.433.2232 Standard TCBY - 2012 Latin America: 1,561.3333824 Europe: +31.76.587.7550 Concept Services L02-006 Printed In U.S A Hev. 11/08 Information and specifications are subject to change without notice. Please confirm at time of order. Copyright ® 2008 InterMetro Industries Corp Asia /Pacific: +65.6567.8003 Middle East /Africa: +971.4.811.8286 Page: 25 John Boos Model: ST6R5- 2460SSK Item 1112 SPECIFICATIONS 1/20/2012 ITEM# 12 - WORK TABLE, 60 ", STAINLESS STEEL TOP (1 REQ'D) John Boos ST6R5-2460SSK Work Table, 60 "W x 24 "D, 16/300 stainless steel top with 5" backsplash & turndown, Stallion safety edge front, 90° turndown on sides, stainless steel legs & adjustable undershelf, KD, NSF Standard TCBY - 2012 REVIEWED FOR CODED R CE A OVED JUL 17 2012 City of Tukwila BUILDING DIVISION CITY MAY 31 2012 PERMIT CEtTR M12-d82 Concept Services Page 26 John Boos ST6R5- 2460SSK 'kips km Item #:12 "ST6R5 -SSK" Stainless Steel Top Work Tables wl Riser w/ 16 Gauge Stainless Steel Work Top w/ Stainless Base & Adjustable Undershelf m Item # Model # Project Qty 16 GAUGE TOP wl ADJUSTABLE UNDERSHELF 24 "WIDE Qty 30 "WIDE Qty 36 "WIDE Qty ST6R5- 2436SSK ST6R5- 3036SSK ST6R5- 3636SSK ST6R5- 2448SSK ST6R5- 3048SSK ST6R5- 3648SSK ST6R5- 2460SSK ST6R5- 3060SSK ST6R5- 3660SSK ST6R5- 2472SSK ST6R5- 3072SSK ST6R5- 3672SSK ST6R5- 2484SSK ST6R5- 3084SSK ST6R5- 36845SK ST6R5- 2496SSK ST6R5- 3096SSK ST8R5- 3696S5K ST6R5- 24108SSK ST6R5- 30108SSK ST6R5- 36108SSK ST6R5- 24120SSK ST6R5- 30120SSK ST6R5- 36120SSK FEATURES: * 16 Gauge Stainless Steel Top with 5" Riser & turndown Type 300 stainless steel with # 3 polish, satin finish * Top is Sound Deadened * Reinforced with 1 "x2" channel running entire length of table * 1 1/2" Stallion Edge on front and rear with side edges 90 degree bend down for table line -up * Stainless Steel Base with Adjustable Undershelf * Adjustable bullet feet * Shipped knocked -down, easy - to - assemble * NSF Approved CONSTRUCTION: Top: Stainless Steel Tops are TIG welded, Exposed welds are polished to match adjacent surface. MATERIAL: Top: 16 gauge stainless steel Type 300 stainless steel with # 3 polish, satin finish Shelf: 18 gauge stainless steel ** 36" Wide Tables, 16 Gauge Lower Shelf Legs: 1 5/8" Round O.D., 16 gauge tubular galvanized steel Gussets: Stainless Steel Feet: 1" adjustable stainless steel bullet feet Standard TCBY - 2012 OPTIONAL ACCESSORIES MODEL # Qty DRAWER DRAWER LOCK CASTERS OVERSHELVES SINKS POT RACK John Boos & Co 315 South First Street - Effingham, IL 62401 Phone: 217- 347 -7701 - Fax: 217- 347 -7705 Email: sales @johnboos.com - Web -site: www. johnboos.com Concept Services Page: 27 GG -1 John Boos L L CLEARANCE = L-8" W 1 1 1/2" 1 Adj All units ship unassembled for reduced shipping cost. Units 7 ft. and larger are furnished with six legs. All dimensions are typical. Tolerance +1- .500". ST6R5- 2460SSK Item #:12 DETAILED SPECIFICATIONS 1_ Turndown on Back Splash s' r. CLEARANCE = L- 9.625 "_ 2 WT. 36" WIDE . 1 1 16 GAUGE TOP & UNDERSHELF Finished size of undershelf. Shelf length = length minus 4.875" Shelf width = width minus 4.25" L 24" WIDE WT. 30" WIDE WT. 36" WIDE WT. 36 ST6R5- 2436SSK 56 ST6R5- 3036SSK 63 ST6R5- 3636SSK 80 48 ST6R5- 2448SSK 69 ST6R5- 3048SSK 78 ST6R5- 3648SSK 87 60 ST6R5- 2460SSK 82 ST6R5- 3060SSK 93 ST6R5- 3660SSK 104 72 ST6R5- 2472SSK 95 ST6R5- 3072SSK 111 ST6R5- 3672SSK 123 84 ST6R5- 2484SSK 112 ST6R5- 3084SSK 128 ST6R5- 3684SSK 144 96 ST6R5- 2496SSK 129 ST6R5- 3096SSK 176 ST6R5- 36965SK 165 108 ST6R5- 24108SSK 142 ST6R5- 30108SSK 163 S76R5- 36108SSK 183 120 ST6R5- 24120SSK 155 ST6R5- 30120SSK 178 ST6R5- 36120SSK 200 5 = Heigth of Riser w/ turndown — R = Riser Top Work Table 6 = 16. ga Work Surface ST = Stainless Steel Top 1 ST6R5- 30120SSK 30 = Width of Work Surface 120 = Length of Work Surface SS = Stainless Legs & Shelf K - K.D. w/ Adjustable Shelf John Boos as Co 315 South First - Effingham, IL 62401 Phone: 217 - 347 -7701 - Fax: 217- 347 -7705 Email: sales @johnboos.com - Web -site: www.johnboos.com ._, John BOOS Same 1887 March 2011 John Boos is constantly engaged in a program of improving products and therefore reserves the right to change specification without prior notice Standard TCBY - 2012 Concept Services Page: 28 GG -2 Metro Model: VARIES Item #13 SPECIFICATIONS 1/20/2012 ITEM# 13 - SHELVING, WIRE (1 REQ'D) Metro VARIES Super Erecta® Shelf, wire, sizes varyL, chrome- plated finish, plastic split sleeves are included in each carton ACCESSORIES Mfr Qty Model Spec Metro Standard TCBY - 2012 1 VARIES Super Erecta• Post, sizes vary, for use with stem casters, chrome plated finish • REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2012 City of Tukwila BUILDING DIVISION crtrAin MAY 31 2012 PERMIT CENTER Concept Services M 111;041T Page 29 .' Metro VARIES Item #:13 Item # Job SUPER ERECTA SHELF° WIRE SHELVING • Unique Design: The open wire design of these shelves minimizes dust accumulation and allows free circulation of air, greater visibility of stored items and greater light penetration. • Durable Construction: Super Erecta shelves and posts are constructed of heavy -gauge carbon steel or Type 304 stainless steel. • Choice of Finishes: Super Erecta Bite' and chrome- plated for dry storage; Metroseal 3'" with Microban® antimicrobial product protection and stainless steel for corrosive environments; and attractive epoxy color options for merchandising applications. • Versatile: Super Erecta Shelf® wire shelving can adapt to your changing needs. By using various accessories, hundreds of shelving configurations become possible. • Fast, Secure Assembly: SiteSelect`" Posts have a double groove visual guide feature every 8" (203mm), circular grooves at 1" (25mm) increments, and are numbered at 2" (50mm) intervals. A patented, tapered split sleeve snaps together around each post. Tapered openings in the shelf corners slide over the tapered split sleeves providing a positive lock. Shelf is assembled in minutes without the use of any special tools. • Adjustability: Shelves can be adjusted at 1" (25mm) intervals along the entire length of the post. • Shelf Ribs: Run front to back, allowing you to slide items on and off shelves smoothly. • Shelf Accessibility: Shelves can be loaded /unloaded easily from all sides This open construction allows maximum use of storage cube. • Adjustable Feet: Bolt levelers compensate for surface irregularities. Note: Stainless stationary posts are equipped with stainless steel leveling feet. 'MICROBANCe and the MICROBAN4' symbol are registered trademarks of the Microban Products Company, Hunlersville, NC, Standard TCBY - 2012 InterMetro Industries Corporation North Washington Street Wilkes- Barre, PA 18705 www.metro.com EMERSON.. Concept Services Page: 30 Metro VARIES Item #:13 SUPER ERECTA SHELF® WIRE SHELVING Wire Shelves Split Sleeve Model No Super Erecta dote Aluminum Split Sleeve • Metroseal 3: Metro's proprietary epoxy coating contains Microban® antimicrobial product protection. Microban antimicrobial protects the epoxy coating from bacteria, mold, mildew, and fungus that cause odors, stains, and product degradation. • See spec sheet 10.14 for epoxy color options. • Plastic split sleeves are included with each shelf Replacements are available: Cat. No. 9985 (bag of 4) • Aluminum split sleeves are recommended for abusive mobile applications and autoclave applications. Cat. No. 9986Z (bag of 4 with zinc C- rings) Cat. No, 9986S (bag of 4 with stainless steel C- rings) • Load capacity (evenly distributed) per shelf Depths: 14" to 24" (355 to 610mm) 800 lbs. (363kg) for lengths of 18" to 48" (457 to 1219mm) 600 lbs. (272kg) for lengths of 54" (1370mm) or longer • Load capacity (evenly distributed) per unit. Stationary shelving units have a maximum load capacity (evenly distributed) of 2,000 lbs. (907kg) Mobile units have a maximum capacity of three times the caster load rating up to but not exceeding 1,000 lbs. (453kg) total. Consult the Metro catalog for caster load ratings • SUPER ERECTA SHELF meets Government Specifications MIL- S- 40144E. Approx Model No Model No Model No Nominal Width/Length Pkd. WI Chrome Metroseal 3 with Microben" Stainless (in) (mm) (lbs.) (kg) 1424BR 1424NC 1424NK3 1424NS 14x24 355x610 6 2.7 1430 BR 1430NC 1430NK3 1430NS 14x30 355x760 7 3.2 1436BR 1436NC 1436NK3 1436NS 14x36 355x914 8 3.6 144288 1442NC 1442NK3 1442NS 14x42 355x)066 9'/2 4.3 1448BR 1448NC 1448NK3 1448NS 14x48 355x1219 10'/2 4.7 1460138 1460NC 1460NK3 1460NS 14x60 355x1524 14 6.3 1472BR 1472NC 1472NK3 1472NS 14x72 355x1829 17 7.7 1824BR 1824NC 1824NK3 1824NS 18x24 457x610 7 3.2 1830BR 1830NC 1830NK3 1830NS 18x30 457x760 8 3.6 1836BR 1836NC 1836NK3 1836NS 18x36 457x914 972 4.3 184288 1842NC 1842NK3 1842NS 18x42 457x1066 11 5.0 184888 1848NC 1848NK3 1848NS 18x48 457x1219 12 5.4 1854BR 1854NC 1854NK3 1854NS 18x54 457x1370 14'/z 6.6 1860BR 1860NC 1860NK3 1860NS 18x60 457x1524 17 7.7 1872BR 1872NC 1872NK3 1872NS 18x72 457x1829 20 9.1 2124BR 2124NC 2124NK3 2124NS 2.1x2.4 530x610 8 3.6 2130BR 2130NC 2130NK3 2130NS 21x30 530x760 9 4.1 2136BR 2136NC 2136NK3 2136NS 21x36 530x914 11 5.0 214288 214 2NC 2142NK3 2142NS 21x42 530x1066 12 5.4 2148BR 2148NC 2148NK3 2i48NS 21x48 530x1219 14 6.4 2154BR 2154NC 2154NK3 2154NS 21x54 530x1370 16 7.3 2160BR 2160NC 2160NK3 2160NS 21x60 530x1524 18 8:2 2172BR 2172NC 2172NK3 2172NS 21x72 530x1829 24 10.9 2424BR 2424NC 2424NK3 2424NS 24x24 610x610 9 4.1 2430BR 2430NC 2430NK3 2430NS 24x30 610x760 11 5.0 2436BR 2436NC 2436NK3 2436NS 24x36 610x914 13 5.9 2442BR 2442NC 2442NK3 2442N5 24x42 610x1066 15 6.8 2448BR 2448NC 2448NK3 2448NS 24x48 610x1219 16 7.3 2454BR 2454NC 2454NK3 2454NS 24x54 610x1370 19 8.6 2460BR 2460NC 2460NK3 2460NS 24x60 610x1524 21 9.5 2472BR 2472NC 2472NK3 2472NS 24x72 610x1829 26 11.8 Note: 14' (355mm) deep units. Frco- standing units' Foot plates should be used and secured to the floor Mobile unit& maximum allowable post imight is 54" (1370mm) Standard TCBY - 2012 Concept Services Page: 31 Metro VARIES Item #:13 SUPER ERECTA SHELF® WIRE SHELVING SiteSelect'M Posts Stationary Posts Stationary posts are equipped with a leveling bolt to account for uneven floors. • Height includes leveling bolt (completely tightened) and post cap Leveling bolt can be adjusted 1/2' (13mm). • Foot plates may be ordered separately and installed in place of leveling foot. • Replacement leveling bolts Zinc Cat. No. RPF04 -004 Stainless Steel Cat. No. RPF04 -004C • Replacement post cap for standard posts Black Cat. No. RPC06 -035 Model No. Chrome 7P 13P 27P 33P 54P 63P 74P 86P '96P Model No. MetrOseal 3 with Micmben Model No. Stainless Steel 13PK3 13PS 27PS 33PK3 33PS 54PK3 54PS 63PK3 63PS 74PK3 74PS 86PK3 86PS Approx. Height Pkd. Wt (h.) (ram) (Ibs.) 73 /a 187 1/2 14'/e 365 1 283/e 720 1'/4 343/a 873 2 5011 1382 3 62'/1a 1565 3'/2 (kg) 0.3 0.5 0.75 0.9 1.4 1.6 74'1e 1892 4 1.8 867A 2197 5 2.3 981/2 2450 57, 2.5 '06P 4hni lld not be u4ed no units lets than 24' (610mm) deep Cancun MntrO Engineenng for agernetn rernmmendalions Mobile Posts (For use with Stem Casters) • Height includes post cap. Model No. Model No Metroseal 3 Model No Height Chrome with Microban Stainless Steel (in.) (mm) 27UP 27UPS 273/+ 704 33UP 33UPK3 33UPS 33'/4 857 54UP 54UPK3 54UPS 53'3/h6 1366 63UP 63UPK3 63UPS 61'a /1a 1570 70UPK3 693/4 1771 74UP 74UPK3 74UPS 73'/2 1876 86UP 86UPK3 86UPS 857/a 2181 Approx Pkd WI (Ibs.) (kg) 13/4 0.75 2 0.9 3 1.4 392 1.6 3'/4 1.7 4 1.8 4'/2 2.0 Staked Posts (For use with Truck Dollies) • Each post connects to the truck dolly through the stem receptacle. The stem receptacle is staked into the bottom of the post to ensure a durable connection in abusive mobile applications. • Each includes a leveling /connecting bolt. Model No. Chrome 54P -STKD 63P -STKD 74P-SIKD Model 140. Stainless Steel 54PS -STKD 63PS -STKD 74PS•STKD Hrighl (in.) (mml 5411s 1382 621/16 1585 74'/2 1892 Approx Pkd Wt (Ibs ) (kg) 3 1.4 3'/2 1.6 4 1.8 Swedged Posts (For use with Stem Casters in Cart Wash Applications) • Each post has an aluminum cap swedged into the top of the post. • A0pnn Model No Height Pkd WI Stainless Steel (in.) (min) (Ibs ) (kg) 33UPS -SW 333/4 857 2 0.9 54UPS -SW 53 " /I6 1366 3 1.4 63UPS -SW 6113/1s 1570 3'/2 1.6 Standard TCBY - 2012 Concept Services S1teSelect Posts feature double grooves every 8" (203mm) to aid assembly. Special Length Posts Special length cut posts are available. Consult your Metro representative for more information. Page: 32 • Metro VARIES Item #:13 Job SUPER ERECTA SHELF® WIRE SHELVING Super Wide Shelving • High - density Storage: Super Wide° shelves have a greater storage area for holding large quantities of supplies, especially large, bulky objects, providing maximum storage in minimum space. • Load Capacity (evenly distributed) per shelf: Depths: 30" and 36' (760 and 914mm) 600 lbs. (272kg) for lengths 48" (1219mm) or shorter. 400 lbs. (181kg) for lengths 54" (1370mm) or longer. Model No. Approx Model No. Metroseal 3 Model No Nominal Width/Length Phd WI Chrome with Microban Stainless Steel (in.) (mm) (Ibs.) (kg) 3036NC 3036NK3 3036NS 30x36 760x914 15 6.8 3048NC 3048NK3 3048NS 30x48 760x1219 21 9.5 3060NC 3060NK3 3060NS 30x60 760x1524 261/2 11.8 3072NC 3072NK3 3072NS 30x72 760x1829 31 14.0 3636NC 3636NK3 3636NS 36x36 910x914 18 8.2 3648NC 3648NK3 3648NS 36x48 910x1219 23 10.4 3660NC 3660NK3 3660NS 36x60 910x1524 29 13.1 3672NC 3672NK3 3672NS 36x72 910x1829 34'/2 15.4 Foot Plates • • Use to bolt units to the floor, or when a broader, more stable foot is desired. Foot plates also help to protect floors by distributing the point load of the shelving unit across a larger contact point. • Foot plates (completely tightened) add 1/e' (3mm) to the specified heights of each stationary post on the table. Zinc Cat. No. 9993Z Stainless Steel Cat. No. 9993S "S " Hook • Used to add on shelving units with only two posts required. Order two per shelf level. Cat. No. 9995Z All Metro Catalog Sheets are available on our Web Site: www.metro.com InterMetro Industries Corporation North Washington Street, Wilkes- Barre, PA 18705 Phone: 570 -825 -2741 Fax: 570 -825 -2852 For Product Information: Latin America: 1.561.333.3824 U.S. and Canada: 1.800.433.2232 Europe: +31.76.5877550 Standard TCBY - 2012 Concept Services L02 -006 Printed in U.S A. Rev 1 1/08 Information and specifications are subject to change without notice. Please confirm at time of order. Copyright m 2008 InterMetro Industries Corp Asia /Pacific: +65.6567.8003 Middle East /Africa: +971.4.811.8286 Page: 33 John Boos Model: 3B184 -2D18 Item #17 SPECIFICATIONS 1/20/2012 ITEM# 17 - SINK, THREE (3) COMPARTMENT (1 REQ'D) John Boos 38184 -2D18 Sink, (3) 18" wide x 18" front -to -back x 14" deep compartments, (2) 18" drainboards, 10" high boxed backsplash with 2" return to wall at 45° & 1" turned down rear lip, corners coved at 3/4" radius, bottom of bowls drain to 3 -1/2" dia. die stamped opening, (1) set faucet holes, 16/300 s /s, 1 -5/8" OD stainless steel legs with 14/4" OD adjustable side bracing, stainless steel gussets, adjustable stainless steel bullet feet, NSF Standard TCBY - 2012 REVIEWED FOR CODE COMPLIANCE APPROVED JUL .17 2012 City of Tukwila BUILDING DIVISION CIAMIA MAY 312012 PERMIT CENTER MIQO'2 Concept Services Page 39 John Boos BOOS s 1887 3B184 -2D18 Item#:17 "3B -2DB" "B" Series Sinks Three Compartment Sinks wl 2 Drainboard w/ Stainless Steel Base & Bracing FEATURES: * Standard 16 Gauge Type 300 stainless steel with # 4 polish, satin finish • 14" Deep Bowls * All Comers, both vertical and horizontal, coved at 3/4" radius • Bottoms of bowls formed for drainage to 3 -1/2" diameter die stamped opening * Full length 10" High Boxed Backsplash, with 2" return to wall at 45 degree and 1" turned down rear lip • 1 -1/8 "Faucet Holes in Backsplash * All outside corners of assembly are Bullnosed to provide safe,clean and polished edge * Standard stainless steel legs 1 -5/8" diameter * Legs located directly under sink bowls, providing increased stability and maximum weight support CONSTRUCTION: Top: Stainless Steel Sinks are TIG welded, Exposed welds are polished to match adjacent surface. Bases: Stainless Steel Bases are MIG welded MATERIAL: Bowls & 16 gauge stainless Steel Top: Type 300 stainless steel with # 4 polish, satin finish Legs: 1 5/8" Round O.D. stainless steel Bracing: 1 1/4" Round O.D., stainless steel Gussets: Stainless Steel Feet: 1" adjustable stainless steel bullet feet Standard TCBY - 2012 STANDARD: 16 ga. 300 S/S welded Bowls 16 ga. 300 S/S Drainboards and Splash 10" Back Splash STANDARD 16 Gauge Qty 3818204 -2D18 3B184 -2018 3818244 -2018 3618244 -2024 3620304 -2020 3820304 -2024 '38244 -2D24 (') w/ 2 sets of Faucet Holes Bowl Sizes: 16 "X20" 18" X 18" 18" X 24" 20" X 30" 24 "X 24" OPTIONAL ACCESSORIES Qty FAUCETS ADD -A- FAUCETS PRE -RINSE UNITS LEVEL WASTE OVERSHELVES POT RACK John Boos & Co 315 South First Street - Effingham, IL 62401 Phone: 217- 347 -7701 - Fax: 217- 347 -7705 Email: sales @johnboos.com - Web -site: www. johnboos.com Concept Services Page: 40 P -41 John Boos BOWLS F 0 H 16 X 20 25.1/2° 20" 12- 15/16" 18 X 18 23 -1/2" 18" 14-15/16" 18 X 24 29 -1/2" 24" 14- 15/16" 24 X 24 29-1/2" 24" 14-15/16" 35 1/4 GF 111 A 16 -1/4" B 14" C 1o" D 43" 11 O c 3B184 -2D18 DETAILED SPECIFICATIONS All dimensions are typical. Tolerance +/- .500 ". All units ship unassembled for reduced shipping cost. Item #:17 STANDARD 16 GAUGE MODEL DRAIN SIM: DIMENSIONS O 0 16 X20 X14 STANDARD 16 GAUGE MODEL BOWL SIZE DIMENSIONS DB WT. 3816204 -2018 16 X20 X14 87" X 25 -1/2" 18" 380 38184 -2018 18 X 18 X 14 93" X 23 -1/2" 18" 360 3B18244 -2D18 18 X24 X 14 93" X 29 -112" 18" 395 3818244 -2024 18 X 24 X 14 105" X 29 -1/2" 24" 440 3B20304 -2D20 20 x 30 x 14 103" x 35 -1/2" 20" 580 3820304 -2D24 20 x 30 x 14 111" x 35 -1/2° 20" 600 *38244 -2024 24 X 24 X 14 123" X 29 -1/2" 24" 550 John Boos 8a. Co 315 South First - Effingham, IL 62401 Phone: 217 - 347 -7701 - Fax: 217 - 347 -7705 Email: sales@johnboos.com - Web -site: www.Johnboos.com BBOJohn O s.ro,ear We OS September 2011 John Boos Is constantly engaged In a program of improving products and therefore reserves the right to change specification without prior notice Standard TCBY - 2012 Concept Services Page: 41 P-42 T & S Brass B- 0133 -B Item #:17A T &S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 Rua.tA2WI L 19001 Travelers Rest, SC: 800 -476 -4103 Simi Valley, CA: 800 -423 -0150 Fax: 864- 834 -3518 www.tsbrass.com Model No. B- 0133 -B Item No. This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity Customer/Wholesaler Contractor Architect/Engineer 44" Flex Hose w/ Overhead Spring & Spray Valve Assembly Flex Hose, Overhead Spring & Spray Valve Assembly Not Shown for Clarity EPAct 2005 Compliant B- 0109 -01 004R s 6" Wall Finger Hook Bracket B -0107 Spray Valve 1.42 GPM 3/8" NPT x 18" Riser — Easylnstall Lock Nut & Bushing Lever Handles w/ Color Coded Indexes & Spring Check Eterna Cartridges 02" 8" [51 m m] [203mm] Flanges w/ 1/2" NPT Female Inlets Mounting Surface Product Specifications: EasyInstall Pre -Rinse Unit: 8" c/c Wall Mount Mixing Faucet, 1/2" NPT Female Inlets, 18" Riser, Overhead Spring, 44" Flex Hose, B -0107 Spray Valve & Bracket Drawn KJG Checked DHL Approved JHB Scale: 1:8 Date: 10/22/08 Standard TCBY - 2012 Concept Services .Shpph 1 of 9 Page: 43 T & S Brass B- 0133 -B Item #:17A T &S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 REG. 1A2601 I50 /9001 Travelers Rest, SC: 800-476 -4103 Simi Valley, CA: 800 -423 -0150 Fax: 864 - 834 -3518 www.tsbrass.com Model No. B- 0133 -B Item No. ITEM NO. SALES NO. DESCRIPTION 1 B -0107 Spray Valve Asm 2 010476 -45 #27 Washer 3 000907 -45 Spray Valve Hold Down Ring 4 002987 -40 5 001014 -45 Grip Handle Assembly Washer. B -0100 Hose Barrel 6 B- 0044 -H 2A 44" Flex Hose Assembly, Less Handle 7 002712 -40 Hot Eterna Spindle Assembly w/ Spring Check, Handle, Index & Screw 8 001661 -45 Red Index -HW 9 012443 -40 10 EZ -K Hot Eterna Spindle Assembly w/ Spring Check Easylnstall Kit: Bushing, 0 -Ring, Lock Washer & Loctite 222 11 000888 -45 Easylnstall Overhead Spring 12 000821 -40 Spring Body 13 B- 0109 -01 6" Wall Bracket Assembly 14 004 R Finger Hook Assembly 15 000369 -40 3/8" NPT x 18" Long Riser 16 002711 -40 Cold Eterna Spindle Assembly w/ Spring Check, Handle, Index & Screw 17 000922 -45 Lever Handle Screw 18 001660 -45 Blue lndex -CW 19 001638 -45 Lever Handle 20 012442 -40 Cold Eterna Spindle Assembly w/ Spring Check 21 001065 -45 0 -Ring 22 014200 -45 Star Washer. Anti- Rotation 23 001019 -45 Coupling Nut Washer 24 00AA Flange Assembly Product Specifications: Easylnstall Pre -Rinse Unit: 8" c/c Wall Mount Mixing Faucet, 1/2" NPT Female Inlets, 18" Riser, Overhead Spring, 44" Flex Hose, B -0107 Spray Valve & Bracket Drawn KJG Checked DHL Approved JHB Scale: NTS Date: 10/22/08 Standard TCBY - 2012 Concept Services Shaah 9 of 9 Page: 44 T & S Brass Model: B -0156 Item #17B SPECIFICATIONS ITEM# 17B - PRE -RINSE ACCESSORIES (1 REQ'D) T & 5 Brass B -0156 Add -on Faucet, for Prerinse units, 12" nozzle, includes 3" nipple, for Prerinse units Standard TCBY - 2012 1/20/2012 Concept Services Page 45 T & S Brass 8-0156 Item #:17B Standard TCBY - 2012 Concept Services Page: 46 Model No. T T &S BRASS AND BRONZE WORKS, INC. SLIS 2 SADDLEBACK COVE / P.O. BOX 1088 / TRAVELERS REST, SC 29690 ' PHONE 800- 476 -4103 FAX 864- 834 -3518 REO.P2S01 ISO ,9002 B-01 5 6 Item No,: Job Name: Architect /Engineer Approval: Notes: 12" ADA COMPLIANT PRE -RINSE RISER PIPE [305mm] 11 5/16" [287mm] SOLD SEPARATELY. 2 5/16" LESS TIP IS MALE ....--0-4 I [59mm] THREAD FOR AERATOR 1 1/4 TURN w HANDLE w Hill I I 3/8 NPT FEMALE ADD- ON -FCT. BODY. f — DIVERTS FLOW TO SWING NOZZLE. NOT A FULL SHUT OFF. 8 9/16" :111 • ' 1-----i- [218mm] i 3/8" NPT MALE. FITS STD. T &S RIGID BASE FCTS. '5, $ BASE FCTS SOLD ;'►Itt } - I - -C$ "' l SEPARATELY L.- J l• "° f • w NOTES: 1. THE ADD -ON FAUCET IS AN ADDITION TO PRE -RINSE UNITS AND IS INSTALLED IN OUTLETS OF BASE MIXING FAUCETS OF UNITS BEFORE FITTING RISER PIPE, AS SHOWN. 2. LEVER HANDLE CONTROLS WATER ON -OFF THRU NOZZLE ONLY; PRESSURE IS ALWAYS "ON" IN RISER PIPE. (CONTROLLED BY BASE FAUCET). Nroduct Description: ADD -ON FAUCET WITH 12" SWING NOZZLE AND 1/4 TURN HANDLE Drawn: WJS Checked JKD Scale: 1 :4 Approved MVW Dote: 8/18/99 Standard TCBY - 2012 Concept Services Page: 46 T & S Brass Model: B -3952 SPECIFICATIONS ITEM# 17C - LEVER WASTE (3 REQ'D) T & 5 Brass B -3952 Twist Waste Valve, 3 -1/2" sink opening, 2" drain outlet (replaces B -3913, B -3917) Standard TCBY - 2012 Item #17C 1/20/2012 Concept Services Page 47 T & S Brass B -3952 Item #:17C T &S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 Model No. B -3952 REG. #A2601 Item No 150 09071 Travelers Rest, SC: 800 -476 -4103 Simi Value, CA: 800- 423 -0150 Fax: 864 - 834 -3518 www.tsbrass.com This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity Customer/Wholesaler Contractor Architect/Engineer Removable Snap -in Strainer 2" NPT Male Thread, 1 -1/2" NPT Female Thread 12 1/4 "±1/4" [312mm] Product Specifications: Rotary Waste Valve w/ Twist Handle, 3 1/2" Sink Opening, 2" NPT Male / 1 -1/2" NPT Female Outlet Standard TCBY - 2012 Twist Handle w/ Heat Resistant Plastic Grip (Shown in Open Position) LOCKED 60° 180° CLOSED HANDLE ORIENTATION Drawn Checked Approved DHL JRM JHB Scale: Date: 1:4 3/19/07 OPENED Shoat. 1 of ') Concept Services Page: 48 T & S Brass B -3952 T &S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 Item #:17C Model No. B -3952 REG, PA260, Item No. wow, , Travelers Rest, SC: 800 - 476 -4103 Simi Valley, CA: 800 -423 -0150 Fax: 864 - 834 -3518 www.tsbrass.com ITEM SALE NO. DESCRIPTION 1 010389 -45 0 -Ring, Plunger 2 010390 -45 Ferrule, Coupling Nut 3 010391 -45 Nut, Coupling For Twist Drain 4 010382 -45 Gasket, 3 1/2" Face Flange 5 010384 -45 Flange, 3 1/2" Face 6 010386 -45 Strainer, 3 1/2" Snap -in Removable 7 010388 -45 Plunger, Twist Drain 8 010393 -45 Rod Assembly, Twist 0 Washers, 0 -Rings & Gaskets are included Parts Kit B -39 -K Also Furnished w/ Sealing Cap When Overflow Tube Coupling Nut is Not Used. PN# 012640 -45 Product Specifications: Rotary Waste Valve w/ Twist Handle, 3 1/2" Sink Opening, 2" NPT Male / 1 -1/2" NPT Female Outlet Standard TCBY - 2012 Drawn Checked Approved DHL JRM JHB Scale: Date: 1:4 3/19/07 Shaat• 9 of 9 Concept Services Page: 49 Metro Model: SMART WALL Item #14 SPECIFICATIONS 1/20/2012 ITEM# 14 - SHELVING, WALL GRID PANEL (1 REDID) Metro SMART WALL Smart Wall G3 Wire Grid, Metroseal 3 epoxy coated corrosion- resistant finish with Microban® antimicrobial protection; brackets not included Standard TCBY - 2012 REVIEWED FOR CODE PROVED CE AP JUL 17 2012 City of Tukwila BUILDING DIVISION cm8iFtrAtA MAY 312012 PERAM'1'CENTER M I- 4n/ Concept Services Page 34 Metro SMART WALL Item #:14 SmartWall G3TM System Organized, efficient wall space at work. A unique storage and work station system for often underutilized space - empty walls. SmartWall G3 and its system of integrated wall tracks offer the flexibility to add wall shelving and wall mounted task stations where needed throughout a facility. The use of the system around and above sinks, work tables, and equipment will keep these areas cleaner and more organized. Smart Wall G3 can become an integral part of everyday. operating processes to improve efficiencies and ultimately the return on Investment (ROI). Task Station (medium duty) with accessories for a sink /prep area. Task Stet on (standard duty) with accessories for a food prep area. Adjustable Wall Shelving • Flexible, Robust Design: Wall tracks and uprights are designed to interface with wood studs, plywood, concrete, and other suitable wall structures. • Configurations Task Stations: unique combinations of wall tracks, shelves, grids, and accessories. Adjustable Wall Shelving: standard Metro Super Erecta wire and solid, MetroMax Q, and MetroMax iT" shelves can be used with the SmartWall G3 shelf supports. • Easy to Adjust: Uprights and grid brackets can be easily repositioned along the track. Heavy gauge uprights: 1 -1/2" (38m) vertical adjustment of shelves and grids Grids: 3" (76mm) vertical and horizontal adjustment of accessories • Easy to Install: Simply attach the wall tracks to a proper mounting structure. The wall tracks provide a level mounting surface for uprights and grid brackets. Hang the uprights or grid brackets from the track. Configure the task station or wall shelving. Finally, secure the uprights or bottom grid brackets to the wall. • Easy to Clean: Shelves, shelf supports, and grids can easily be removed for thorough cleaning of walls. Wall tracks and uprights can easily be wiped clean. • Durable Finishes: Super Erecta Brite for dry environments; Metroseal 3 epoxy for wet or damp environments with built -in Microban® antimicrobial product protection to inhibit the growth of bacteria, mold, mildew, and fungus that cause odors and product degradation. . MICROBAN and the MICROBAN symbol are registered trademarks of the Microban Products Company, Muntersville, NC. Standard TCBY - 2012 InterMetro Industries Corporation North Washington Street Wilkes- Barre, PA 18705 www.metro.com EMERSON METRO) SmartWall G3TM System Concept Services Page: 35 Metro SMART WALL Item #:14 SmartWall G3 Specifications • Wall tracks: 12 gauge cold rolled steel; obround mounting holes located at 8" (204mm) increments; first and last holes are located 4" (102mm) from the ends of the track; obround hole dimensions (1/8 x 3/4 "; 3 x 19mm). Wall tracks include stop fasteners for the ends of the tracks and joiner plates for connecting adjacent tracks. • Uprights: 12 gauge cold rolled steel; slotted every 1 -1/2" (38mm); 1 -1/8" (29mm) diameter mounting holes are spaced every 6" (152mm) along the upright • Shelf Supports: cold rolled steel; sleeve is high density polyethylene (HDPE) • Shelves: standard Super Erecta wire and solid, MetroMax Q, or MetroMax i'"' shelves may be used. See catalog sheets 10.01, 10.20, 9.20, and 9.21 for shelving specifications. • Finishes: standard finishes for components are Metro BRITE for dry environments and Metroseal 3 epoxy for wet or damp environments. Metroseal 3 contains built -in Microban® antimicrobial product protection to protect the product from bacteria, mold, mildew, and fungus that cause odors and product degradation. • Wire Grids: 1/4" (6mm) diameter cold rolled•steel wire • Grid bracket kits: 14 gauge, type 304 stainless steel • Grid Accessories: see catalog sheet 10.44 • Cleaning instructions: Clean with mild detergents and damp cloths. Do not use abrasive materials because these may damage the protective coatings. Configurations SmartWall G3 offers limitless configurations. The following are examples and meant to demonstrate how to configure the basic product. Accessories can be added to these base units. Task Station (medium duty) Components [qty] [1] Wall Track [2] Uprights [4] Single shelf supports [2] Super Erecta shelves [1] Grid (same length as shelf) Task Station (standard duty) Components [qty] [1] Wall Track [1] Grid bracket kit (cat. no. SWGB1) [1] Grid [1] Grid shelf with retaining edge [same length as grid] Standard TCBY - 2012 Adjustable Wall Shelving Components [qty] [2] Wall Tracks [3] Uprights (4] Single shelf supports [2] Double (intermediate) shelf supports [4] Super Erecta shelves Task Station (standard duty) Components [qty] [1] Grid bracket kit (cat. no. SWGB2) [1] Grid Concept Services Page: 36 Metro Components SMART WALL Wall Tracks (minimum one per system) • Joiner plates and stop fastener hardware included. Does not include hardware to mount wall tracks to the wall. • Packed one track per carton. • Replacement joiner plate (1) and stop fastener hardware (2 sets): cat. no. RPTRK -HDWE Cat. No. Cat. No. Actual Length Actual Depth Actual Brite zinc Metroseal 3 (in.) (mm) (In.) (mm) (In.) ISW40612 " ':SW.40K3 :2 40; 3 1016y ' ::=x3 /_4, ;�.4 .1,. ;.gr 1;;9/16 SW56BR _ SW56K3 56 1423 3/4 19 1-9/16 itW113 ' - SW72K3 72;`F.71-829. -* "µ3' /Ai•`--19 "..•`•.`I'T9%16 NOTE: Tracks can be cut to length, but Metro does not provide this service. Metroseal 3 tracks is available. Cat. No. TP -K2 Item #:14 SmartWall G3 y %. K7 %2 XI Width Approx. Pkd. Wt. (mm) (Ibs.) (kg) 40 6.0 2.6 Touch up paint for Medium duty configurations consist of wall tracks, uprights, shelf supports, and grids Uprights (for medium duty applications, minimum two per system) • Built -in slots allow shelf supports and grids to attach without tools or hardware. • 1 -1/2" (38mm) slot spacing allows shelves and grids to be adjusted on 1 -1/2" (38mm) increments • Sold by the piece; packed two per carton Cat. No. Cat. No. Number Actual Length Actual Width Actual Depth Approx. Pkd. Wt. Brite zinc Metroseal 3 of slots (in.) (mm) (in.) (mm) (In.) (mm) (Ibs.) (kg) (swin.p RuSWU1sK3 7 16 406 111'/8 29 a- 1 Z/8: 48 rta I)glin SWU3OBR SWU30K3 17 31 787 1 -1/8 29 1 -7/8 48 3.5 1.5 SWl14SBR SVYl145CK3 ' 26' .. 44'- `1%2." 1130! .31" 1/8 294 °..."1= /8! W48?a 5 =3 2:3 Shelf Supports • Mount directly to slotted uprights • Single shelf supports are used on each end of a stand -alone unit or side -by -side unit (pictured). Sold by the piece; packed two per carton. • Double (intermediate) shelf supports are used when configuring side -by -side wall shelving units. Sold by the piece; packed one per carton. Single Shelf Supports Cat. No. Cat. No. Actual Brite zinc Metroseal 3 Flts shelf depth (in.) 4SWS14BRIS _W51,4_K3;14;,;($55 In) 16A%16, SWS18BR SWS18K3 18" (457mm) 20 -9/16 LSw5218R SWS21K3: ?l 1(530mm)j 23 9/j16_ SWS24BR SWS24K3 24" (610mm) 26 -9/16 Length Actual Width (mm) (in.) (mm) 522 1 -1/2 38 675 1 -1/2 38 Single support Actual Height Approx. (In.) (mm) (Ibs.) 8.3/.16 :: 208_ ; METRO SmartWall G3TM System Metro SmartWall G3 SMART WALL Item #:14 Standard duty configurations consist of wall tracks (optional), grid brackets, and grids. Grid Mounting Brackets (for standard duty applications without uprights) • For standard duty applications, grids may be mounted directly to the track or directly to the wall without a track using SmartWall G3 grid bracket kits. Cat. No. Description SWG62 Direct wall mount bracket kit; Consists of (6) bottom brackets Approx. Pkd. Wt. Ibs, (k? 2.0 0.9 Bottom bracket: Top bracket: connects to wall connects to track Grids • Grids are a mounting surface for task management accessories, • See spec sheet 10.43 for grid accessories. Cat. No. Cat, No. Width x Length Approx. Pkd. Wt. Plated Metroseal3 (in.) (mm) (Ibs.) (kg) - WG1830K3 ; . 18x30 457x760 7,5 3,3 WG1836BR WG1836K3 18x36 457x914 9,0 4.1 WG1848111R ING1848K3 18x48 ..457x1219 12.0 5.4= WG1860BR WG1860K3 18x60 457x1524 14.0 6.4 WG243011C3 , 24x35 ''610x91.4 r' , 12;0 5.4 WG2448K3 24x48 610x1219 15.5 7.0 4WG303610 a30x36 ` 76Ox91,4 ' , §s 12,8 3 .• 5,8 WG3048K3 30x48 760x1 19 16.5 7.5 NOTE: • Grids can mount directly to the uprights without brackets. • Mount a grid directly to the track with bracket kit model SWGB1. • Mount a grid directly to the wall without a track with bracket kit model SWGB2, Weight capacities are based on a !tend -alnne unit with a wall track, two uprights, and any combination of shelves and grids. Structures into which wall tracks are mounted Wood Studs Woods Studs with cross-stud reinforcement Plywood: Minimum thickness - 1/2" (13mm) Concrete Metal Studs Environmental room and walk -in cooler walls (appropriately reinforced) Weight capacity per shelf (Super Erecta, MetroMax Q, MetroMax I) !Per Unit 400 Ibs. (180kg) 400 Ibs. (180kg) 400 Ibs. (180kg) 1200 Ibs. (90kg) '1013 lbs. (45kg) (:consult your Metro representative 250 Ibs. (113kg) not to exceed the overall stated weight !capacity of the unit based on the wall structure Weight capacities for adlacent unit; that share an upright. ... .. - i : 1/2 the stated weight capacity of a stand -alone unit 'based on the wall structure !Shelf! 125 Ibs. (56kg) not to exceed the overall weight I capacity of the unit based on the wall structure. General Rule Weight capacities for grids and grid shelves Grid 250 lbs. (113kg) 5014s. (22.Skg) Grid shelf with retaining edge Adjacent units with a shared upright Grid and Grid shelf Standard TCBY - 2012 InterMetro Industries Corporation North Washington St. Wilkes- Barre, PA 18705 For Product Information: U.S. and Canada: 1.800.433.2232 Latin America: 1.561,333.3824 Europe: +31(0)76.587.75.50 Asia /Pacific: +65.6567.8003 Middle East/Africa: +971.4.811.8286 L02 -181 8/09 Information and specifications are subject to change without notice. Please confirm at the time of order. Concept Services Page: 38 John Boos Model: 1B244 -1D24L OR R Item #18 SPECIFICATIONS 1/20/2012 ITEM# 18 - SINK, ONE (1) COMPARTMENT (1 REQ'D) John Boos 18244 -1D24L OR R Sink, (1) 24" wide x 24" front to back x 14" deep compartments, (1) 24" left or right drainboard, 10" high boxed backsplash with 2" return to wall at 45° & 1" turned down rear lip, corners coved at 3/4" radius, bottom of bowl drain to 3 -1/2" dia. die stamped opening, (1) set faucet holes, 16 /300 s /s,1- 5/8" OD stainless steel legs with 1 -1/4" OD adjustable side bracing, stainless steel gussets, adjustable stainless steel bullet feet, NSF Standard TCBY - 2012 REVIEWED FOR CODE PROV CE AP ED JUL 1.7 2012 City of Tukwila BUILDING DIVISION CITY MAY 31 2012 PERMIT CENTER Concept Services Page 50 V' John Boos Boos Snca I 7 1 B244 -1 D24L OR R Item #:18 "1 B -1 DB" "B" Series Sinks One Compartment Sinks w/ 1 Drainboard w/ Stainless Steel Base & Bracing FEATURES: * Standard 16 Gauge Type 300 stainless steel with # 3 polish, satin finish * 14" Deep Bowls , * All Corners, both vertical and horizontal, coved at 3/4" radius * Bottoms of bowls formed for drainage to 3 -1/2" diameter die stamped opening * Full length 10" High Boxed Backsplash, with 2" return to wall at 45 degree and 1" turned down rear lip * 1 -1/8" Faucet Holes in Backsplash * All outside corners of assembly are Bullnosed to provide safe,clean and polished edge * Standard stainless steel legs 1 -5/8" diameter * Legs located directly under sink bowls, providing increased stability and maximum weight support CONSTRUCTION: Top: Stainless Steel Sinks are TIG welded, Exposed welds are polished to match adjacent surface. Bases: Stainless Steel Bases are MIG welded MATERIAL: Bowls & 16 gauge stainless Steel Top: Type 300 stainless steel with # 3 polish, satin finish Legs: 1 5/8 ". Round O.D., stainless steel Bracing: 1 1/4" Round O.D., stainless steel Gussets: Stainless Steel Feet: 1" adjustable stainless steel bullet feet Standard TCBY - 2012 STANDARD: 16 ga. 300 S/S welded Bowls 16 ga. 300 S/S Drainboard and Splash 10" Back Splash STANDARD 16 Gauge Qty 1B16204-1D18 1B184-1D18 1B18244-1D18 1B18244 -1D24 1B244-1D24 Must specify Left or Right Dralnboards Bowl Sizes: 16" X 20" 18" X 18" 18" X 24" 24" X 24" OPTIONAL ACCESSORIES Qty FAUCETS ADD -A- FAUCETS PRE -RINSE UNITS LEVEL WASTE OVERSHELVES POT RACK John Boos & Co 315 South First Street - Effingham, IL 62401 Phone: 217- 347 -7701 - Fax: 217- 347 -7705 Email: sales @johnboos.com - Web -site: www. johnboos.com Concept Services Page: 51 P -27 John Boos BOWLS 16 X 20 25 -1/2" 20" 12- 15/16" 18 X 18 23 -1/2' 18' 11- 15/16" 18 X 24 29 -1/2" 24° 14- 15/16" 24 X 24 29 -1/2' 24" 14- 15/16" F 0 �H- 35 1/4 A 16 -1/4" B 14" C 1o" D 43" c 1 B244 -1 D24L OR R DETAILED SPECIFICATIONS L All dimensions are typical. Tolerance +1- .500 ". All units ship unassembled for reduced shipping cost. DRAINBOARD SIZE Item #:18 STANDARD 16 GAUGE MODEL BOWL SIZE DIMENSIONS DB WT. 1816204 -1018 16 X 20 X 14 38" X 25 -1/2" 18" 65 113184 -1018 18 X 18 X 14 40" X 23 -1/2" 18" 62 1B18244 -1018 18 X 24 X 14 40" X 29 -1/2" 18" . 70 1018244 -1024 18 X 24X 14 46" x 29 -1/2" 24" 82 10244.1 D24 24 X 24 X 14 52" X 29-1/2" 24" 135 John Boos 8s Co 315 South First - Effingham, IL 62401 Phone: 217 -347 -7701 - Fax: 217 - 347 -7705 Email: sales @Johnboos.com - Web -site: www.Johnboos.com John WA BOOS snoe 1887 May 2009 John Boos Is constantly engaged In a program of improving products and therefore reserves the right to change specification without prior notice Standard TCBY - 2012 Concept Services Page: 52 P -28 T & S Brass Model: B =0231 Item #18A SPECIFICATIONS 1/20/2012 ITEM# 18A - FAUCET (1 REQ'D) T & S Brass B -0231 Sink Mixing Faucet, with 12" swing nozzle, wall mounted, 8" centers on sink faucet with 1/2" IPS eccentric flanged female inlets, lever handles HOT SIZE HOT GPM COLD SIZE FILTERED SIZE CONDENSER INLET SIZE CONDENSER OUTLET SIZE 1/2" 1/2" 1 Standard TCBY - 2012 INDIRECT SIZE WASTE DIRECT SIZE Concept Services Page 53 T & S Brass B -0231 T &S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 ri0 Item #:18A Model No. B -0231 REG #A2601 • Item No. uo awXoi Travelers Rest, SC: 800 -476 -4103 Simi Valley, CA: 800 - 423 -0150 Fax: 864 - 834 -3518 www.tsbrass.com This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity Customer/Wholesaler Contractor Architect/Engineer Variations or Applicable Options: -WH6 6" Wrist Action Handles -WH4 4" Wrist Action Handles -175F 4 -Arm Kitchen Handles 7 7/8" [200mm] 062X 12" Swing Nozzle w/ Stream Regulator Lever Handles w/ Colored Indexes \ 12" [305mm] 5 1/8" [131 mm] 8" [203mm] Adjustable from 7 3/4" to 8 1/4" (197rnrn to 210rnm] _\ 512" [51 mm[ w/ 1/2" NPT Female Inlets Product Specifications: 8" c/c Wall Mount Mixing Faucet w/ 1I2" NPT Female Eccentric Inlet Flanges, Lever Handles, 12" Swing Nozzle w/ Stream Regulator Standard TCBY - 2012 Concept Services 2 3/8" ._*-1 [61mrn] Drawn Checked Approved WJS JRM JHB Scale: Date: 1:4 10/19/06 Shaah 1 of ') Page: 54 T & S Brass B -0231 T &S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 Item #:18A Model No. B -0231 RE(: NAsnoi Item No. LSO #9Q0) Travelers Rest, SC: 800 -476 -4103 Simi Valley, CA: 800 - 423 -0150 Fax: 864 - 834 -3518 www.tsbrass.com ITEM PART NO. DESCRIPTION 1 00AA 00AA Flange Asm 2 001019 -45 CpIg Nut Washer 3 005959 -40 Eterna Barrel Asm -Cold 4 005960 -40 Eterna Barrel Asm -Hot 5 177F Lever Handle 6 000922 -45 Lever Handle Screw 7 001660 -45 Blue Index -CW 8 001661 -45 Red Index -HW 9 062X 062X Swing Nozzle Product Specifications: 8" c/c Wall Mount Mixing Faucet w/ 1/2" NPT Female Eccentric Inlet Flanges, Lever Handles, 12" Swing Nozzle w/ Stream Regulator Standard TCBY - 2012 Drawn Checked WJS JRM Scale: 1:4 Approved JHB Date: 10/19/06 Shoat. 9 of 9 Concept Services Page: 55 T & 5 Brass Model: B -3952 Item #188 SPECIFICATIONS 1/20/2012 ITEM# 18B - LEVER WASTE (3 REQ'D) T & S Brass B -3952 Twist Waste Valve, 3 -1/2" sink opening, 2" drain outlet (replaces B-3913, B -3917) Standard TCBY - 2012 Concept Services Page 56 T & S Brass B -3952 Item #:18B T &S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 Model No. B -3952 REG.02601 Item No. uo #904 Travelers Rest, SC: 800 -476 -4103 Simi Valley, CA: 800 - 423 -0150 Fax: 864 - 834 -3518 www.tsbrass.com This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity Customer/Wholesaler Contractor Architect/Engineer Removable Snap -in Strainer 4 1/2" [114mm] � Eiti Qa 04 7/16" [113mm] 2 5/8" [68mm] 2" NPT Male Thread, 1 -1/2" NPT Female Thread 12 1/4 "±1/4" [312mm] Product Specifications: Rotary Waste Valve w/ Twist Handle, 3 1/2" Sink Opening, 2" NPT Male / 1 -1/2" NPT Female Outlet Standard TCBY - 2012 Concept Services Twist Handle w/ Heat Resistant Plastic Grip (Shown in Open Position) LOCKED 4 60° CLOSED HANDLE ORIENTATION Drawn DHL Scale: 180° Checked JRM OPENED Approved JHB Date: 1:4 3/19/07 Shoot. 1 of Page: 57 T & S Brass B -3952 T &S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 Item #:186 Model No. B -3952 REG 0A2601 Item No. 6O M90 I Travelers Rest, SC: 800 - 476 -4103 Simi Valley, CA: 800 -423 -0150 Fax: 864 - 834 -3518 www.tsbrass.com ITEM SALE NO. DESCRIPTION 1 010389 -45 0 -Ring, Plunger 2 010390 -45 Ferrule, Coupling Nut 3 010391 -45 Nut, Coupling For Twist Drain 4 010382 -45 Gasket, 3 1/2" Face Flange 5 010384 -45 Flange, 3 1/2" Face 6 010386 -45 Strainer, 3 1/2" Snap -in Removable 7 010388 -45 Plunger, Twist Drain 8 010393 -45 Rod Assembly, Twist 0 Washers, 0 -Rings & Gaskets are included Parts Kit B -39 -K Also Furnished w/ Sealing Cap When Overflow Tube Coupling Nut is Not Used. PN# 012640 -45 Product Specifications: Rotary Waste Valve w/ Twist Handle, 3 1/2" Sink Opening, 2" NPT Male / 1 -1/2" NPT Female Outlet Standard TCBY - 2012 Drawn Checked Approved DHL JRM JHB Scale: Date: 1:4 3/19/07 Shaft. 9 of • Concept Services Page: 58 John Boos Model: PBHS =W- 1410 -P Item #19 1/20/2012 SPECIFICATIONS ITEM# 19 - SINK, HAND (1 REQ'D) John Boos PBHS -W- 1410 -P Hand Sink, wall mount, 14" wide x 10" front -to -back x 5" deep, faucet, all stainless steel construction (Splash Mount faucet included) I WATER HOT SIZE HOT GPM COLD SIZE FILTERED SIZE CONDENSER INLET SIZE CONDENSER OUTLET SIZE 1 /2" 1 1 1 /2" Standard TCBY - 2012 INDIRECT SIZE DIRECT SIZE WASTE 1 -1/Z" REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2012 City of Tukwila BUILDING DIVISION cm MAY 3 1 2012 PERMIT CENTER ikAl2.014- Concept Services Page 59 09 :stied seOIAJeS ldaouo3 0 2 8 O b m j i N z 0 O Y z U d NO v rn Z 1.0Z - A831 pepuelg SHEET NUMBER: QUAD LOCATION: ROOM NUMBER: ITEM NUMBER: HANSOMS QUANTITY: MODEL NUMBER: PBH&W1410P SCALE: DATE 41005 DRAWN BY: MB SALES ORDER NUMBER 6 L : #wall d-OM-M-SHBd PRO BOWL S INKS JOHN BOOS & CO. B0"05 qm soo8 uyor John Boos Model: PBDISINK101410 Item #20 SPECIFICATIONS 1/20/2012 ITEM# 20 - DROP -IN SINK (1 REQ'D) John Boos PBDISINK101410 Drop -In Sink, one compartment, 10" wide x 14" front to back x 10" deep bowl, 16 /300 stainless steel, (faucet not Included) I WATER HOT SIZE HOT GPH COLD SIZE FILTERED SIZE CONDENSER INLET SIZE CONDENSER OUTLET SIZE REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1'7 2012 City of Tukwila BUILDING DIVISION Standard TCBY - 2012 Concept Services INDIRECT SIZE DIRECT SIZE I WASTE 2" R V CITY MAY 31 2012 PERMIT CENTER Page 61 John Boos Model: PBF -4 -D Item #20A SPECIFICATIONS 1/20/2012 ITEM# 20A - FAUCET (1 REQ'D) John Boos PBF -4 -D Economy Faucet, deck mounted, 4" centers, 3 -1/2" gooseneck spout (WRIST BLADES NOT AVAILABLE) I WATER HOT SIZE HOT GPH COLD SIZE FILTERED SIZE CONDENSER INLET SIZE CONDENSER OUTLET SIZE 1/2" 1/2" Standard TCBY - 2012 INDIRECT SIZE DIRECT SIZE I WASTE Concept Services Page 62 Vita -Mix Model: 570 SPECIFICATIONS Item #21 1/20/2012 ITEM# 21- DRINK MIXER (1 REQ'D) Vita -Mix 570 (VM0800) Mix'n MachineTM Frozen Dessert Machine, standard, countertop, permanent soft ice cream agitator, DOES NOT include foot control - must be purchased separately, 5 yr. parts & labor warranty, 1/4 peak HP, 120V, 50/60 Hz, 2.6 amps, UL, cUL listed, NSF certified ACCESSORIES ELECTRICAL ELECTRICAL 2 Mfr Qty Model Spec Vita -Mlx 1 120 volt standard, std. VOLTS CYCLE (H2) PHASE CONN AFF NEMA AMPS KW HP MCA MOCP 120 50 /60 1 2.6 .312 1/4 120 60 1 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2012 City of Tukwila BUILDING DIVISION Standard TCBY - 2012 Concept Services crtr MAY 31 2012 PERMIT CENTER M12 -9$9„ Vita -Mix 570 Item #:21 N THE VITA -MIX® MIX'N MACHINE'"", THE INDUSTRY'S LEADING FROZEN DESSERT MIXER, CAN INCORPORATE CANDIES, COOKIES AND OTHER HARD -TO -MIX INGREDIENTS INTO Q HARD / SOFT SERVE ICE CREAM OR YOGURT TO MAKE HIGHLY PROFITABLE FROZEN W DRINKS. THE MACHINE IS AVAILABLE IN BOTH COUNTERTOP AND WALL MOUNT MODELS. z IV 0 c z MIX'N MACHINE' ITEM NUIVBER DESCRIPTION 570 Standard Mix'n Machine - Permanent Soft Ice Cream Agitator 27 lbs. 112.2 kg., 2.3 cu. ft. /.06 cu. m* 571 Standard Mix'n Machine - Removable Agitator, includes 10 removable agitators, 27 lbs. 712.2 kg., 2.3 cu. ft. /.06 cu. m* . 577 Standard Mix'n Machine - Permanent Hard Ice Cream Agitator 19 lbs. / 9.3 kg., 1.1 cu. ft. / .03 cu. m* 572 Wall Mount Mix'n Machine - Permanent Soft Ice Cream Agitator 19 lbs. / 8.62 kg., 1.1 cu. ft. / .03 cu. m* 573 Wall Mount Mix'n Machine - Removable Agitator includes 10 removable agitators,19 lbs. / 8.62 kg., 1.1 cu. ft. / .03 cu. m* 57° Wall Mount Mix'n Machine- Permanent Hard Ice Cream Agitator 19 lbs. / 8.62 kg., 1.1 cu. ft. / .03 cu. m* These Item Numbers are for 120VAC. Other voltages are also available. 241 /4 inches/ 60.9 cm L10 inches /j 25.4 cm 20 inches 51 cm L Standard TCBY - 2012 L__1 7 1/4 inches/ 18.5 cm COUNTERTOP 570 571 577 24 1/4 inches/ 60.9 cm L inc hes/ 20.3 cm — n 572 20 573 inches/ 51 cm 578 1— WALL MOUNT I I 8 3/4 inches/ 22 cm MIX'N MACHINE'" Frozen Dessert Mixer Specifications: RPM 3,440 (60Hz.) / 2840 (50Hz.) bare motor speed 120VAC, 50/60 Hz, 2.7 amps Other voltages available 1 per standard pack *Mix'n Machine models do not include foot control - must be purchased separately. STANDARD PERMANENT AGITATOR MODEL #VM0800 STANDARD REMOVABLE AGITATOR MODEL #VM0800A WALL MOUNT PERMANENT AGITATOR MODEL #VM0804 WALL MOUNT REMOVABLE AGITATOR MODEL #VM0804A °1* NSF. wwI when applicable F O O D S E R V I C E Concept Services Page: 64 Beverage Air Model: MMF23 -1 -W Item #25 SPECIFICATIONS 1/20/2012 ITEM# 25 - FREEZER, MERCHANDISER (1 REQ'D) Beverage Air MMF23 -1 -W MarketMax"M Freezer Merchandiser, reach -in, one - section, (1) triple pane glass door, 23 cu. ft. capacity, electronic control, digital display, (5) epoxy coated steel shelves, fluorescent interior lighting, self closing door w /automatic hold -open feature, anti - microbial door handles, bottom - mounted refrigeration, white exterior, 1/2 hp, UL, cUL, UL -EPH, ENERGY STAR ®, MADE IN USA ACCESSORIES ELECTRICAL Mfr Qty Model Spec Beverage Air 1 Limited Warranty: 1 yr parts and labor Beverage Air 1 Additional 4 yr compressor warranty, standard Beverage Air 1 115v/60/1 -ph, 10.9 amps, 8' cord, NEMA 5 -15P, standard VOLTS CYCLE (HZ) PHASE CONN AFF NEMA AMPS KW HP MCA MOCP 115 60 1 Standard TCBY - 2012 8' cord & plug 5 -15P 10.9 1/2 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2012 City of Tukwila BUILDING DIVISION crrvSMItiA MAY 31 2012 PERMIT CENTER AA19:-(762. Concept Services Page 65 Beverage Alr MMF23 -1 -W Item #:25 II/ ij u` _ ' ' BEVERAGE-AIR 1L�i► 3779 Champion Blvd., Winston - Salem, NC 27105 1- 888 - 845 -9800 Fax# 1-336-245-6453 http: //www.Beverage- Air.com Commercial Refrigeration Equipment General Specification MARKETMAXT*' MERCHANDISER SERIES —GLASS DOOR MERCHANDISER Single section glass door merchandiser with lighted sign panel used for merchandising and storage of frozen food, frozen novelty items and cold product. CABINET CONSTRUCTION Heavy duty construction includes white coated steel interior walls. Exterior finish is heavy -duty steel with a baked on durable coating. Choose from black or white finish. S/S exterior and black interior options are available. Foamed -in -place CFC and HCFC -free polyurethane insulation Modern, one -piece grille is easily removed for cleaning and servicing. Refrigerators have double pane, IowE argon filled glass doors. Freezer models have heated triple pane glass. Inside and outside panes are tem- pered for added safety. Anti - microbial door handles are standard. Door provides automatic hold -open feature. Brightly lighted sign panel. SHELVING Five (5) heavy duty epoxy coated wire shelves per section standard. Four (4) shelf clips included per shelf (field installed). Shelves are adjustable In '' /:° increments. ELECTRONIC CONTROL Electronic thermostat with manual defrost button provides a digital display of cabinet temperatures, which includes status indicators and key pad for any necessary temperature adjustments. REFRIGERATION Self- contained bottom mount refrigeration system. Expansion valve refrig- erant control on freezer provides quick temperature pull down and reduces compressor run time — meaning reduced energy consumption. Includes automatic condensate disposal. Refrigerators utilize ozone friendly R134a refrigerant. Freezers utilize ozone friendly R404A refrigerant and its defrost system is fully automatic, time - initiated and temperature terminated operation. Freezer product temperatures from –10 °F to –15 °F. Refrigerator product temperatures from 36 °F to 38 °F. ELECTRICAL Interior fluorescent lighting enhances product illumination. Optional LED lighting provides hidden light source for increased product visibility. LED bulbs last up to 10 times longer compared to fluorescent bulbs and renders additional energy savings due to reduced wattage load on compressor. Refrigerator and freezer units are wired at factory and ready for connection to a 115/60/1 phase, 15 amp dedicated outlet. 8' long cord and plug set included. YEAR USA •Nnta• ,Int all marlrinne ma,, anal,/ 61 =11 mnrlal ,mrlalinnc Standard TCBY - 2012 Item No Quantity HINGED GLASS DOOR MARKETMAXTM MERCHANDISER SERIES MM23 Refrigerator and,Freezers Single Door MODELS: MMR23 -1 -B MMR23 -1 -W MMR23 -1 -B -LED MMR23-1-W-LED MMF23 -1 -B MMF23 -1 -W MMF23 -1 -B -LED MMF23 -1 -W -LED MMR23 -1 -S (SHOWN IN VS EXTERIOR) White and Black Exterior finishes available MMF23 -1 -S (SHOWN IN S/S EXTERIOR) White and Black Exterior finishes available SPECIAL FEATURES • MMR23 and MMF23 have earned the ENERGY STAR® • Anti - microbial door handle • Electronic control with digital display • Brightly lighted sign panel • Optional LED lighting • Available options: S/S Exterior, Black Interior, Wine Racks, Spring Feed Dividers, Casters, Audible Alarm With PM Feature, Smart Defrost 11516011 NEMA -5.15P ELECTRICAL CONNECTION Units pre -wired at factory and include 8' long cord and plug set. Available From: Concept Services Page: 66 Beverage Air MMF23 -1 -W Item #:25 Model Specified Store# Location Quantity BEVERAGE -AIR MarketMaxM Glass Door Merchandisers Model: MMR23, MMF23 MODEL MMR23 MMF23 EXTERNAL DIMENSIONAL DATA r 1 r 1' Length Overall (inches) - includes handle Length Overall (mm) - includes handle 27 1/4" 692 27 1/4" 592 Depth Overall (inches) Daplh Overall (mm) 33 3/4" 857 33 3/4" 857 Height Overall— (inches) Height Overall— (mm) 76• 1961 78" 1961 Number of doors 1 1 Depth with Door Open 90 ° 80" 60" INTERNAL DIMENSIONAL DATA NET Capacity (cubic R) NET Capacity (Liters) 23 651 23 651 Internal Length Overall (inches) Internal Length Overall (mm) 24" 610 24" 610 Internal Depth Overall (inches) Internal Depth Overall (mm) 28 1/2" 724 28 1(2" 724 Internal Height Overall— (inches) Internal Height Overall —(mm) 81 3/4' 1569 81 3/4" 1569 Number of ahelves 5 5 ELECTRICAL DATA Full Load Amperes 115/80/1 5.8 A 10.9 A REFRIGERATION DATA Horsepower 1/3 1/2 WEIGHT DATA Gross Weight (Crated Ibs) 300 325 Gross Weight (Crated kg) 136 147 USa Note: Not all markings may apply to all model variations. 32" __ 27 1/4" 24" INSIDE WIDTH 57 1/4" PLAN VIEWS 78" 61 3/4" INSIDE HEIGHT 78" 32" - -- 33 3/4" 28 1/2" INSIDE DEPTH END 27 1/4" H FRONT BEVERAGE -AIR® CORPORATION 3779 Champion Blvd. • Winston- Salem, NC 27105 USA • (336) 245 -6400 • Fax (336) 245 -6453 • (888) 845 -9800 • www.beverage- air.com Standard TCBY - 2012 Concept Services Page: 67 f1 / I / V r 1 r 1' r..._...._._..__.. \: r 1 FRONT BEVERAGE -AIR® CORPORATION 3779 Champion Blvd. • Winston- Salem, NC 27105 USA • (336) 245 -6400 • Fax (336) 245 -6453 • (888) 845 -9800 • www.beverage- air.com Standard TCBY - 2012 Concept Services Page: 67 Master -Bilt Products Model: DD -46L SPECIFICATIONS Item #27 1/20/2012 ITEM# 27 - DISPLAY CASE, DIPPING, GELATO ICE CREAM (1 REQ'D) Master -Bilt Products DD -46L Ice Cream Dipping /Display Cabinet, low- glass, (8) 3 gallon can display, (4) 3 gallon storage, painted textured galvanized steel interior and exterior, 46" high s/s serving deck, low front glass view windows, fluorescent light w /switch, temp range 5° to -5 °F, 115v/60/1, 1 /2hp, 7.5amps, 9' cord, NEMA 5 -15P, UL, cUL, NSF ACCESSORIES Mfr Qty Model Spec Master-8k Products Master -Bilt Products Master -Bilt Products Master -Bilt Products Master -Bilt Products Master -Bilt Products 1 1 1 1 1 1 44 -00984 A062 -20301 NOTE: If third party carrier is used, this freight class does NOT apply Two year limited parts and labor warranty Three year extended compressor warranty White textured finish, standard Can Covers, clear (each) for DD series Can Holders, includes white can covers, for DD- 46/D D -46L /DD- 46CG /D D -46LCG VOLTS CYCLE (HZ) PHASE CONN AFF NEMA AMPS KW HP MCA MOCP ELECTRICAL 115 60 1 5 -15P 7.5 1/2 ELECTRICAL REMARKS 9' cord & plug Standard TCBY - 2012 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2012 City of Tukwila BUILDING DIVISION Concept Services R CITY MAY 31 2012 PERMIT CENTER MizOz Page 68 Master -Bilt Products NIS. Refrigeration Solutions DD-46L MBMASTER-D11r Item #:27 ITEM NO. PROJECT LOCATION DATE QTY. DD/DD-CGIDD-L SERIES Deluxe Ice Cream Dipping /Display Merchandisers STANDARD MODELS 0 DD -26 ❑ DD -46 0 DD -66 0 DD -88 CURVED LOW GLASS GLASS MODELS MODELS O DD -26CG 13 DD -26L U DD -46CG 0 DD -46L ❑ DD -66CG 0 DD -66L O DD -88CG 0 DD -88L FEATURES CONSTRUCTION • Attractive, contemporary design • 24 gauge painted textured interior and exterior • Equipped with leveling legs to cor- rect for unlevel flooring situations • Rear air intake and discharge elimi- nates front grille and allows full front of cabinet for graphics • Independent on /off compressor and light switch • Stainless steel top and attached superstructure • "tempered plate glass viewing win- dow • Drain with garden hose connector for ease of cleaning • Brilliant, interior fluorescent lighting • Stainless steel serving deck • Top and side lid wiper gaskets • Heavy -duty epoxy - coated wire can support racks • 9 ft. Tong cord with molded plug • 21/4" foamed -in -place "zero ODP" urethane insulation • Number and length of interior light fixtures: — DD- 26/26CG/261. (1) 18" — DD- 46/46CG/46L (1) 36" — DD-66 /661. (1) 18 ", (1) 36" — DD -66CG (2) 18" — DD- 88/88CG/881 (2) 36" LIDS • Hinged, high- tensile, transparent acrylic dipping compartment lids with full length handle REFRIGERATION • Refrigerant: — DD- 26/26CG/261., DD- 46/46CG/46L R -134a — DD -66 /66CG /66L, DD- 88/88CG/88L R -404A • Cold wall evaporator • Low maintenance bare tube condenser coil on all models except Dl)- 26/26CG/26L • No minimum clearance required on cabinet sides but front, back and top must be left open for customer and operator access • Temperature range: 5° to -5 °F ( -15° to -21 °C) • R- factor (insulation efficiency rat- ing): 19.40 WARRANTY • Standard limited three year extend- ed compressor and two year limited parts and labor gIMASTEB -GILT• / 908 Highway 15 North • New Albany, MS 38652 Refrigeration soMons / PHONE: 800- 647 -1284 or 662 -534 -9061 • FAX: 800 -232 -3966 or 662 -534 -6049 • www.master- bilt.com Standard TCBY - 2012 Concept Services Page: 69 Master -Bilt Products DD-46L Item #:27 MitDD/DD- CG/DD -L SERIES DELUXE ICE CREAM DIPPING /DISPLAY MERCHANDISERS OPTIONS 0 Rear service doors for DD -46, DD -66 and DD -88 models (factory installed) ❑ Custom colors ❑ Removable can holders with white overnight can covers ❑ Dipper well 0 Removable frost shields 0 Leg kit 0 Casters 0 Lid locking kit (less locks) ❑ Flavor identification tabs (for DD and DD -CG models only) 0 Ice cream pan rack assembly (pans not included) 1101MIME e erfi- Ft•!._: sa::x:rp ��. '1 17...11101111=1.111 REAR SERVICE DOOR FOR DD -46, DD -66 AND DD -88 DD-46 MODELS DD -66 & DD -88 MODELS 11.75" x 14.625" DOOR OPENING DOOR SIZE: 13.25' X 16.125" FROST SHIELDS FLAVOR IDENTIFICATION TAB Standard TCBY - 2012 LID LOCKING KIT CAN HOLDERS Concept Services Page: 70 Master -Bilt Products DD-46L Item #:27 TECHNICAL SPECIFICATIONS `Height of standard and low glass models: 50" (1270mm), curved glass models: 52" (1321 mm). * *Car acities in 91/ " diameter, 3 gallon cans. 'Measured to the load line level. DD -26 - 22 -1/8" DD-46 - 43" DD -66 - 64 -318" DD -88 - 85 -7/8" 'DISTANCES ARE STANDARD ON ALL MODELS PLAN VIEW STANDARD SIDE VIEW LISTINGS Standard TCBY - 2012 DD -26 - 26-1/2" DD -46 - 47-3/4" DD-66 - 69 -1/4" DD -88 - 90.3/4" SAFE LOAD LEVEL- DD-28- 22.1VOMITSTORAGE —w COMPARTMENT _11Z�DD-46- 19-12' 0. 1181+1 10.718" • OD-80 - 62.3/8' STANDARD & CURVED GLASS ELEVATION VIEW CURVED GLASS SIDE VIEW 10 -5/8" ON STANDARD — AND CURVED GLASS MODELS DD -26L- 26.1/2" DD-46L- 47 -3/4" DD- 88L- 90./4" DD-88L- 90 -3314" SAFE LOAD LEVEL i' DO-26{.- 22•18' OMIT STORAGE COMPARTMENT .._ 7''3-1/2: E1O-45 •1S1R' '„•OD66L•46116 "-*4 10 -7/8" 00-881.- 62-3/8' L ( LOW GLASS ELEVATION VIEW LOW GLASS SIDE VIEW HOOKUP Via plug in, 9 foot long, flexible 3 wire 14/3 cord with molded plug. Drain hookup has standard garden hose connection. Concept Services NEMA 5 -15P Page: 71 DIMENSIONS DIMENSIONS CAN CAP.'" SHIP (in.) (mm) UNIT DISPLAY/ CAP. SHIP W1'. MODEL L D H L D H VOLTS AMPS H.P. STORAGE CU. FE.? CU. FP. LB /KG DD- 26/26CG/261. 261/2 271/4 • 673 705 • 115 7.4 1/3 4/0 3.5 38.0 240/109 DD- 46/46CG/461. 473/4 7,71/4 * 1213 705 • 115 7.5 1/2 8/4 9.6 54.0 370/168 DD- 66/66CG/661. 691/4 27 .1/4 • 1759 705 • 115 9.7 1/2 12/8 16.0 76.0 495/225 DD- 88/88CG/88L 901/4 27/4 • 2305 705 • 115 11.5 3/4 16/12 22.5 97.0 600/273 `Height of standard and low glass models: 50" (1270mm), curved glass models: 52" (1321 mm). * *Car acities in 91/ " diameter, 3 gallon cans. 'Measured to the load line level. DD -26 - 22 -1/8" DD-46 - 43" DD -66 - 64 -318" DD -88 - 85 -7/8" 'DISTANCES ARE STANDARD ON ALL MODELS PLAN VIEW STANDARD SIDE VIEW LISTINGS Standard TCBY - 2012 DD -26 - 26-1/2" DD -46 - 47-3/4" DD-66 - 69 -1/4" DD -88 - 90.3/4" SAFE LOAD LEVEL- DD-28- 22.1VOMITSTORAGE —w COMPARTMENT _11Z�DD-46- 19-12' 0. 1181+1 10.718" • OD-80 - 62.3/8' STANDARD & CURVED GLASS ELEVATION VIEW CURVED GLASS SIDE VIEW 10 -5/8" ON STANDARD — AND CURVED GLASS MODELS DD -26L- 26.1/2" DD-46L- 47 -3/4" DD- 88L- 90./4" DD-88L- 90 -3314" SAFE LOAD LEVEL i' DO-26{.- 22•18' OMIT STORAGE COMPARTMENT .._ 7''3-1/2: E1O-45 •1S1R' '„•OD66L•46116 "-*4 10 -7/8" 00-881.- 62-3/8' L ( LOW GLASS ELEVATION VIEW LOW GLASS SIDE VIEW HOOKUP Via plug in, 9 foot long, flexible 3 wire 14/3 cord with molded plug. Drain hookup has standard garden hose connection. Concept Services NEMA 5 -15P Page: 71 Master -ER Products DD-46L Item #:27 DD/DD- CWDD -L SERIES IB// DELUXE ICED CE CREAM DIPPING /DISPLAY MERCHANDISERS BID SPECIFICATIONS Item no. DD- Provide ( ) Deluxe Ice Cream Dipping /Dis- play Merchandiser(s), Master -Bilt model no. DD- Cabinet will feature textured finish on interior and exterior. Cabinet to be provided with inde- pendent on /off compressor and light switch, drain connection, stainless steel top and super- structure, tempered plated glass viewing window and interior fluorescent lighting. Cabinet is to have rear air intake and discharge. Standard leveling legs provided to correct for unlevel flooring situa- tions. Hanging frost shields with mounting screws offered as an op- tion (consult your Master -Bilt rep- resentative for additional options). Cabinet will be provided with 9 foot cord and molded plug. DD- 26/26CG/26L and DD- 46/46CG/46L will use R -134a re- frigerant while DD66/66CG/66L and DD- 88/88CG/88L, will use R -404A refrigerant. The tempera- ture range will be 5° to -5 °F ( -15° to - 21 °C). All models except DD- 26/26CG/26L to be supplied with a refrigeration system containing low maintenance bare tube con- denser coil. Cabinet to have standard limited three year extended compressor warranty and two year limited parts and labor warranty. Cabinet to be UL, C -UL and NSF listed. N(111.: Cabinet designed for optimum perturnfance in air - conditioned arca at 7S'F ambient and S5'!.. relative humidity. \II specilicaliun.e subject to change without notice. MBMASTER -HILT' ���ReMQgerationo�Srolutions tmn"�.nta n+•dr".o Standard TCBY - 2012 1 908 Highway 15 North • New Albany, MS 38652 /J PHONE: 800 - 647 -1284 or 662 -534 -9061 • FAX: 800- 232 -3966 or 662 -534 -6049 • www.master- bilt.cont 274 -3/1 lay OMastcr -Bile Products division of Standen International, Inc. All rights reserved. Printed in U.S.A. Concept Services Page: 72 4 Custom Model: IRTPLPCONE SPECIFICATIONS ITEM# 31- WAFLE CONE BAKER (2 REQ')) Custom ;IRTPLPCONE Waffle Cone Baker Standard TCBY - 2012 REVIEWED CODE COMPLIANCE APPROVED JUL 17 2012 BUILDING f Tukwila DIVISION Concept Services Item #31 1/20/2012 crtvSMAA MAY 31 2012 PERMIT CENTER MI2O 12 Page 73 Custom IRTPLPCONE Item #:31 ®I VDtive products Innovative Products Cone RT Series Waffle Baker Specifications 110 — 120 Volts A/C 1300 -Watts • Approximately 11 Amps Height: 10 'h inches Closed Height: 23 '/2 inches Open Width: 12 inches Overall Length: 25 inches Weight: 21 pounds Auto -Start Timer: No buttons to push. Waffle baker timer will automatically engage after rotating grids. Solid Aluminum Grids with Non - Stick Coating: 6 -ounce grids feature non -stick coating with instant recovery time for high volume users. Cool Touch Safety Handles: Safe and easy grasp design. UL and NSF Listed: UL and NSF approved Standard TCBY - 2012 Concept Services Page: 74 • Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: June 11, 2012 Project Name: TCBY Permit # M12 -082 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Per section 501.2 of the Uniform Mechanical Code Exhaust discharge. The air removed by every mechanical exhaust system shall be discharged outdoors at a point where it will not cause a nuisance and not less than the distances specified in Section 501.2.1. The air shall be discharged to a location from which it cannot again be readily drawn in by a ventilating system. Air shall not be exhausted into an attic or crawl space. Also the mall is considered a corridor and in the case of smoke or fire, it would not be appropriate to blow smoke out into the mall. 2. Please show how outside fre h air will be supplied to this tenant space. . .SE6 t-14E If=6- rse r M4 (,t, GoorzeitiJ4,cQ m `L. PLANS `714 G frtit e & /401,G Sc lsrere,i t ii , Should there be questions concerning the above information please contact the Building Division at 206- 431 -3670. d p don penn • consulting engineer July 10, 2012 RE: TCBY Westfield Southcenter Mall, Suite D36 633 Southcenter Seattle, WA 98188 To whom it may concern: In response to your plan review comments for the above mentioned project, we have made the following corrections to the construction documents or written explanation below. All changes have been clouded delta one: Mechanical Comments: Comment #1: Per section 501.2 of the Uniform Mechanical code Exhaust discharge. The air removed by every mechanical exhaust system shall be discharged outdoors at a point where it will not cause a nuisance and not less than the distances specified in section 501.2.1. the air shall, be discharged to a location from which it cannot again be readily drawn in by a ventilating system. Air shall not be exhausted into an attic or crawl space. Also the mall is considered a corridor and in the case of smoke or fire, it would not be appropriate to blow smoke out into the mall. Response: The supply /exhaust system originally designed to circulate air to the prep area has been removed and replaced by a VAV connected to the LL system. Since the circulation system was removed the exhaust fan discharging into mall common has been removed. Comment #2: Please show how outside fresh air will be supplied to this tenant space. Response: Circulation system originally designed has been removed and replaced by a VAV connected to the LL system. The LL system is .maintained at 20% outside air so the VAV system will provide 90 CFM of fresh air as indicated on M1.1 to the prep area. Seating is open to the mall common and accounted for in the fresh air design of the mall. Plumbing Comments: Comment #1: A grease interceptor is required for this space as a grease waste sewer line is not available per Scott Preister, Regional Tenant Coordinator for Westfield Mall. Please Provide the make and model number with sizing calculations of the proposed interceptor. At a minimum, the pot sink and the triple sink should tie into the grease interceptor and any of the floor sinks that might catch fats, oils or grease. Please provide an elevation or cross - section detail to show all parts of the system including vents, flow control, indirect waste, 635 Westport Parkway, Suite 300 817.410.2858 (office) Grapevine, Texas 76051 817.251.8411 (fax) Electrical • Mechanical • Plumbing Geothermal traps, fixtures etc. Plemp also include the manufacturers sp ('cations and installation instructions for the grinb interceptor. Response: A grease interceptor was added to the sanitary plans on P2.1. The pot sink, 3- comp sink, and all other fixtures that could possible catch fats, grease or oil were connected to the interceptor. The grease interceptor sizing calculation was provided on P2.1. Specification of the interceptor was provided on P2.1 keyed note 4 as well as P1.1 Plumbing Fixture Schedule. Comment #2: Provide the make and specific model number of the proposed backflow device. Include the manufacturer's specification sheet. Response: The manufacturer and model number for the RPZ was added to sheet P2.0 Keyed note 7. Specified to be Watts model #009. Cut sheet is attached. Development Comments: Comment #1: Please show the location of the remote stock room on the area plan on sheet T Response: By Arch Comment #2: The interior lighting budget form submitted is outdated. The correct version is 2009 Interior Lighting Budget. Also, the allowable wattage values have changed. Cafeterias, fast food establishments, restaurants /bars are allowed 1.20 watts /ft. The remote stock room would be storage similar to warehousing. This space would be allowed to have 0.5 watts /sf and it is currently in compliance. You cannot take extra credit from the stock room and apply it to the yogurt shop. Please make adjustments as necessary. I have included a new form with this memo. Response: Updated lighting compliance form is attached. To accommodate reduction in wattage (3) P1 fixtures were removed and the current limiting transformer serving the track lighting was reduced from 150watts to 100 watts. See sheets E1.1 and E2.1. Comment #3: Page A1.0 has references to page A8.3. This page is missing. Please add this page. Response: By Arch 11 you have any questions regarding the above, plea .'. esitate to call. Thank you, Don Penn, PE, CGD Don Penn Consulting Engineer Don Penn Consulting Engineer Page 2 of 2 June 13, 2012 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Bret Ryan Fitch 16435 N Scottsdale Rd, Suite 195 Scottsdale, AZ 85254 RE: Correction Letter #1 Mechanical Permit Application Number M12 -082 TCBY —1119 Southcenter Mall Dear Mr. Ryan, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File No. M12 -082 W:\Pennit Center \Correction Letters\2012\M12 -082 Correction Letter #l.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 k Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: June 11, 2012 Project Name: TCBY Permit # M12 -082 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Per section 501.2 of the Uniform Mechanical Code Exhaust discharge. The air removed by every mechanical exhaust system shall be discharged outdoors at a point where it will not cause a nuisance and not less than the distances specified in Section 501.2.1. The air shall be discharged to a location from which it cannot again be readily drawn in by a ventilating system. Air shall not be exhausted into an attic or crawl space. Also the mall is considered a corridor and in the case of smoke or fire, it would not be appropriate to blow smoke out into the mall. 2. Please show how outside fresh air will be supplied to this tenant space. Should there be questions concerning the above information please contact the Building Division at 206- 431 -3670. OPERM1T COORS COFI. PLAN REVIEW /ROUTING SLIP ACTIVITY,' NUMBER: M12 -082 DATE: 07/11/12 PROJECT NAME: TCBY SITE ADDRESS: 1119 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued D P RTM TS;n t�li B i ng Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 07/12/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/09/12 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: *EMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -082 PROJECT NAME: TCBY SITE ADDRESS: 1119 SOUTHCENTER MALL DATE: 05/31/12 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued Building Division Public Works Awe Ai /A— )- t2 Fire Prevention mi Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 06/05/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required ❑ REVIEWER'S INITIALS: No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions ❑ DUE DATE: 07/03/12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: L2 —1 - 14 Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 02/29/12 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: M12-0814-, Date: .7 - R ' ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # ^ after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: TCBY Project Address: 1119 Southcenter Mall Contact Person: ii•faCrt— Phone Number: _ Z%8© c!q e - LIZOO CInO 1TUKWLA JUL 1 12012 PERMIT CENTER Summary of Revision: S6 (21kricp e-O I M(GG eoeePt ;•ra'KC ,u8-44`L. PLi tJ Sheet Number(s): Gt�y �� ���� tt l t " $(4 e-, "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: [h Entered in Permits Plus on 0 \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople *nter Friendly Page General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name SAYBR CONTRACTORS INC UBI No. 601795367 Phone 2535312144 Status Active Address 3852 South 66Th Street License No. SAYBRCI033L7 Suite /Apt. License Type Construction Contractor City Tacoma Effective Date 6/27/1997 State WA Expiration Date 6/14/2014 Zip 98409 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status JWCONSL954RMJ W CONSTRUCTION SERVICES LLC Construction Contractor General Unused 12/14/2005 3/31/2009 Expired JWDEVDL956DU JW DEVELOPERS LLC Construction Contractor General Unused 3/31/2005 3/31/2007 Inactive Business Owner Information Name Role Effective Date Expiration Date CROWLEY a MACKIN Agent 06/27/1997 Bond Amount MULLER, MICHAEL THOMAS Chief Operating Officer 02/06/2007 LPM09001079 SAY, KAREN MARIE President 06/27/1997 MCALOON, MICHAEL THOMAS Vice President 06/27/1997 HARTFORD FIRE INS BROWN, WINFIELD V Vice President 06/27/1997 06/30/2007 WAYMIRE, JOEL Secretary 06/27/1997 01/14/2005 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 FIDELITY Et DEPOSIT CO OF MD LPM09001079 06/12/2010 Until Cancelled $12,000.0005/27 /2010 3 HARTFORD FIRE INS 52BSBDL7280 06/12/2005 Until Cancelled 06/12/2010 $12,000.0005/25 /2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name' Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 16 Endurance American Specialty I ECC10100703503 05/01/2012 05/01/2013 $1,000,000.00 05/02/2012 15 Endurance American Specialty I ECC10100703502 05/01/2011 05/01/2012 $1,000,000.00 04 /28/2011 14 ENDURANCE AMERICAN SPEC ECC10100703500 05/01/2009 05/01/2011 $1,000,000.00 04 /29/2010 13 HUDSON SPEC INS CO FEC7002746 05/01/2008 05/01/2009 $1,000,000.00 04/30/2008 12 HUDSON SPECIALTY INS CO FEC7000497 11/15/2007 11/15/2008 $1,000,000.00 11/14/2007 https: // fortress .wa.gov /lni /bbip /Print.aspx 07/19/2012 1.0 GENERAL: 1.1 ALL APPLICABLE CODES, LAWS AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS, AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR WHO SHALL INFORM THE OWNER, PRIOR TO SUBMITTING A PROPOSAL, OF ANY WORK OR MATERIALS WHICH VIOLATE ANY OF THE ABOVE LAWS AND REGULATIONS. ANY WORK DONE BY THE CONTRACTOR CAUSING SUCH VIOLATION SHALL BE CORRECTED BY THE CONTRACTOR. 1.2 INVESTIGATE EACH SPACE THROUGH WITH EQUIPMENT MUST BE MOVED. WHERE NECESSARY, EQUIPMENT SHALL BE SHIPPED FROM MANUFACTURER IN SECTIONS OF SIZE SUITABLE FOR MOVING THROUGH AVAILABLE RESTRICTIVE SPACES. ASCERTAIN FROM BUILDING OWNER AT WHAT TIMES OF DAY EQUIPMENT MAY BE MOVED THROUGHALL AREAS. 1.3 DUCTWORK IS SHOWN DIAGRAMMATICALLY AND DOES NOT SHOW ALL OFFSETS, DROPS AND RISES OF RUNS. THE CONTRACTOR SHALL ALLOW IN HIS PRICE FOR ROUTING OF DUCTWORK TO AVOID OBSTRUCTIONS. EXACT LOCATIONS ARE SUBJECT TO APPROVAL OF ARCHITECT. COORDINATION WITH THE EXISTING SERVICES, INCLUDING THOSE OFOTHER TRADES IS REQUIRED. 1.4 SUPPORT ALL DUCTWORK FROM BUILDING STRUCTURE AND /OR FRAMING IN AN APPROVED MANNER. WHERE OVERHEAD CONSTRUCTION DOES NOT PERMIT FASTENING OR SUPPORTS FOR EQUIPMENT, FURNISH ADDITIONAL FRAMING. INSERTS SHALL BE STEEL, SLOTTED TYPE AND FACTORY PAINTED. SINGLE ROD SHALL BE SIMILAR TO GRINNELL FIG. 281. MULTI-ROD SHALL BE SIMILAR TO FEE & MASON SERIES 9000 WITH END CAPS AND CLOSURE STRIPS. MAXIMUM LOADING INCLUDING PIPES, .DUCTWORK CONTENTS AND COVERING SHALL NOT EXCEED 75% OF RATED INSERT CAPABILITY. WHEN SUPPORTING FROM BUILDING USE BEAM CLAMPS IN APPROVED MANNER.', 1.5 INSTALL WORK SO AS TO BE READILY ACCESSIBLE FOR OPERATION, MAINTENANCE AND REPAIR. MINOR DEVIATIONS FROM DRAWINGS MAY BE MADE TO ACCOMPLISH THIS, BUT CHANGES WHICH INVOLVE EXTRA COST SHALL NOT BE MADE WITHOUT APPROVAL. 1.6 REMOVAL AND RELOCATION OF CERTAIN EXISTING WORK WILL BE NECESSARY FOR THE PERFORMANCE OF THE GENERAL WORK. ALL EXISTING CONDITIONS CANNOT BE COMPLETELY DETAILED ON THE DRAWINGS. THE CONTRACTOR SHALL SURVEY THE SITE AND INCLUDE ALL CHANGES IN MAKING UP THE WORK PROPOSAL. 1.7 PLAN INSTALLATION OF NEW WORK AND CONNECTIONS TO EXISTING WORK TO INSURE MINIMUM INTERFERENCE WITH REGULAR OPERATION OF EXISTING FACILITIES. ALL SYSTEM SHUTDOWNS AFFECTING OTHER AREAS SHALL BE COORDINATED WITH BUILDING OWNER. INSTALL ISOLATION VALVES AT POINT OF CONNECTION TO THE EXISTING - PIPING. PROVIDE TEMPORARY DUCT CAPS AND /OR CONNECTIONS TO MINIMIZE SHUTDOWN TIME 1.8 CONNECT NEW WORK TO EXISTING WORK IN NEAT AND APPROVED MANNER. RESTORE EXISTING WORK DISTURBED WHILE INSTALLING NEW . WORK TO ACCEPTABLE CONDITION AS DETERMINED BY ARCHITECT. 1:9•DISCONNECT, REMOVE AND /OR RELOCATE'EXISTING MATERIAL, EQUIPMENT AND OTHER WORK AS NOTED OR REQUIRED FOR PROPER INSTALLATION OF NEW SYSTEM. 1.10 THE CONTRACTOR SHALL KEEP ALL EQUIPMENT AND MATERIALS, AND ALL PARTS OF THE BUILDING, EXTERIOR SPACES AND ADJACENT STREETS, SIDEWALKS AND PAVEMENTS, FREE FROM MATERIAL AND DEBRIS RESULTING FROM THE EXECUTION OF THIS WORK. EXCESS MATERIALS WILL NOT BE PERMITTED TO ACCUMULATE EITHER ON THE INTERIOR OR THE EXTERIOR. 1.11 SEAL OPENINGS AROUND DUCTS AND PIPING THROUGH PARTITIONS, WALLS AND FLOORS (NOT IN SHAFTS) WITH MINERAL WOOL OR OTHER NONCOMBUSTIBLE MATERIAL. 1.12 ALL NECESSARY FLASHING AND COUNTERFLASHING TO MAINTAIN THE WATERPROOFING INTEGRITY OF THIS BUILDING AS REQUIRED BY THE INSTALLATION OF DUCTS AND EQUIPMENT SHALL 3E PROVIDED BY LANLORD'S ROOFING CONTRACTOR AT TENANTS EXPENSE. PROVIDE EQUIPMENT CURBS AS REQUIRED. . 1.13 ALL PRESENT MATERIAL, EQUIPMENT AND CONSTRUCTION DEBRIS TO BE REMOVED UNDER THIS CONTRACT SHALL BECOME THE PROPERTY OF THE CONTRACTOR WITH THE EXCEPTION OF SPECIFIC EQUIPMENT AND APPARATUS REQUESTED BY THE BUILDING REPRESENTATIVE, ARCHITECT OR AS NOTED TO BE RELOCATED ON THE DRAWINGS SHALL BE PROPERLY DISPOSED OF BY THIS CONTRACTOR. 1.14 MATERIALS AND WORKMANSHIP, UNLESS OTHERWISE NOTED; SHALL BE IN ACCORDANCE WITH BUILDING STANDARDS. 1.15 THE WORK IN THE BUILDING SHALL BE DONE WHEN AND AS DIRECTED, AND IN .A MANNER SATISFACTORY TO THE OWNER. THE WORK SHALL BE PERFORMED SO AS TO CAUSE THE LEAST POSSlE LE INCONVENIENCE AND DISTURBANCE TO THE PRESENT OCCUPANTS.. • . 1.16 UNLESS OTHERWISE SPECIFICALLY SPECIFIED, INCLUDE ALL CUTTING AND PATCHING OF EXISTING FLOORS, WALLS, PARTITIONS AND OTHER MATERIALS IN THE EXISTING BUILDING. THE CONTRACTOR SHALL RESTORE THESE AREAS TO ORIGINAL CONDITION. 1.17 REMOVABLE ACCESS TILE AND /OR ACCESS DOOR ARE REQUIRED IN HUNG. CEILINGS, SHAFTS AND WALLS FOR ALL VOLUME AND FIRE DAMPERS, AUTOMATIC DAMPERS AND ALL OTHER MECHANICAL EQUIPMENT AND DEVICES. HVAC CONTRACTOR TO FURNISH ACCESS LOCATION REQUIREMENTS TO GENERAL CONTRACTOR. ACCESS TILE IDENTIFICATION: PROVIDE BUTTONS, TABS, AND MARKERS TO IDENTIFY LOCATION OF CONCEALED DAMPERS AND EQUIPMENT. 1.18 ALL MATERIAL AND EQUIPMENT TO BE NEW UNLESS OTHERWISE NOTED AND SHALL BE IN • . ACCORDANCE WITH BUILDING STANDARDS. 1.19 SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT A CAREFUL EXAMINATION OF THE PORTIONS OF THE EXISTING BUILDING, EQUIPMENT, ETC:, WHICH AFFECT THIS WORK, AND THE ACCESS TO SUCH SPACES, HAS BEEN MADE AND THAT THE CONTRACTOR IS FAMILIAR WITH EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT THE EXECUTION OF THE WORK. LATER CLAIMS SHALL NOT BE MADE FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED, WHICH COULD HAVE BEEN FORESEEN DURING SUCH AN EXAMINATION. THE ON -SITE INSPECTION SHALL VERIFY EXISTING DUCTWORK; PIPING (SIZES, CLEARANCES, ETC) AND CONDITIONS. 1.20 INSURANCE IN ACCORDANCE WITH BUILDING REQUIREMENTS AND SHALL INCLUDE A HOLD HARMLESS CLAUSE FOR OWNER AND ENGINEER. 1.21 THE FINAL ACCEPTANCE WILL BE MADE AFTER THE CONTRACTOR HAS ADJUSTED HIS EQUIPMENT, BALANCED THE VARIOUS SYSTEMS, .DEMONSTRATED THAT IT FULFILLS THE REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS AND HAS FURNISHED ALL THE REQUIRED CERTIFICATES OF INSPECTION AND APPROVAL. 1.22 SPECIFICATIONS ARE OF SIMPLIFIED FORM AND INCLUDE INCOMPLETE SENTENCES: WORDS OR PHRASES SUCH AS "THE CONTRACTOR SHALL," "SHALL BE," "FURNISH," "PROVIDE," "A," "THE," AND "ALL HAVE BEEN OMITTED FOR BREVITY.. 1.23 DEFINITIONS: • 1) "PROVIDE ": TO SUPPLY, INSTALL AND. CONNECT UP COMPLETE AND READY FOR SAFE AND REGULAR OPERATION THE PARTICULAR WORK REFERRED TO UNLESS SPECIFICALLY OTHERWISE NOTED. 2) INSTALL": TO ERECT, MOUNT AND CONNECT COMPLETE WITH RELATED ACCESSORIES. 3) "FURNISH" OR "SUPPLY ": TO PURCHASE, PROCURE, ACQUIRE AND DELIVER COMPLETE WITH RELATED ACCESSORIES. 4) "WORK ": LABOR, MATERIALS, EQUIPMENT, APPARATUS, CONTROLS; ACCESSORIES AND OTHER ITEMS REQUIRED FOR PROPER AND COMPLETE INSTALLATION. i) "CONCEALED ":. EMBEDDED IN MASONRY OR OTHER CONSTRUCTION, INSTALLED IN FURRED SPACES, WITHIN DOUBLE PARTITIONS OR HUNG CEILINGS, IN TRENCHES, IN CRAWL SPACES, OR IN ENCLOSURES. 6) "EXPOSED ": NOT INSTALLED UNDERGROUND OR "CONCEALED" AS DEFINED ABOVE. 7) "SIMILAR" OR "EQUAL ": EQUAL IN MATERIALS, WEIGHT, SIZE, DESIGN AND EFFICIENCY OF SPECIFIED PRODUCT. 2.0 SCOPE OF WORK: 2.1 THE WORK UNDER CONTRACT INCLUDES ALL LABOR, MATERIALS AND APPLIANCES NECESSARY FOR THE FURNISHING, INSTALLING AND TESTING, COMPLETE AND READY FOR SAFE OPERATION OF THE SYSTEMS. WORK SHALL BE INSTALLED IN A NEAT, WORKMANLIKE MANNER. 2.2 THE CONTRACTOR SHALL GIVE NECESSARY NOTICE, FILE DRAWINGS AND SPECIFICATIONS WITH THE DEPARTMENT. HAVING JURISDICTION, OBTAIN PERMITS OR LICENSES NECESSARY TO CARRY OUT THIS WORK AND PAY ALL FEES THEREFORE. THE CONTRACTOR SHALL ARRANGE FOR INSPECTION AND TESTS OF ANY OR ALL PARTS OF THE WORK IF SO REQUIRED BY AUTHORITIES AND PAY ALL CHARGES FOR IT. THE CONTRACTOR SHALL PAY ALL COSTS FOR, AND FURNISH TO THE OWNER BEFORE FINAL BILLING, ALL CERTIFICATES NECESSARY AS EVIDENCE THAT THE WORK INSTALLED CONFORMS WITH ALL REGULATIONS WHERE THEY APPLY TO THIS WORK. 2.3 THE CONTRACTORSHALL FURNISH A WRITTEN GUARANTEE TO REPLACE OR REPAIR PROMPTLY AND ASSUME RESPONSIBILITY FOR ALL EXPENSES INCURRED FOR ANY WORKMANSHIP AND EQUIPMENT IN WHICH DEFECTS DEVELOP WITHIN ONE YEAR FROM THE DATE OF FINAL • CERTIFICATE FOR PAYMENT AND /OR FROM DATE OR ACTUAL USE OF EQUIPMENT OR OCCUPANCY OF SPACES, BY OWNER, INCLUDED UNDER THE VARIOUS PARTS:OF THE WORK, WHICHEVER DATE IS EARLIER. THIS WORK SHALL BE DONE AS DIRECTED BY THE OWNER. THIS GUARANTEESHALL ALSO PROVIDE THAT WHERE. DEFECTS OCCUR, THE CONTRACTOR WILL ASSUME RESPONSIBILITY • FOR ALL EXPENSES INCURRED IN REPAIRING AND REPLACING WORK OF OTHER TRADES • AFFECTED BY DEFECTS, REPAIRS OR REPLACEMENTS IN EQUIPMENT SUPPLIED BY THE CONTRACTOR. MECHANICAL SPECIFICATIONS 2.0 SCOPE OF WORK CONTINUED: 2.4 CONTROLLED INSPECTION BY A LICENSED PROFESSIONAL ENGINEER TO BE HIRED BY THIS CONTRACTOR. 2.5 PRIOR TO THE INSTALLATION OF ANY WORK AND PROCUREMENT OF EQUIPMENT PROVIDE COMPLETE SET OF COORDINATED SHOP DRAWINGS OF ALL NEW MD EXISTING EQUIPMENT, DUCTWORK, PIPING AND CONTROL SYSTEMS INDICATING CAPACITY DIMENSIONS AND SEQUENCE • OF OPERATION FOR WRITTEN APPROVAL BY THE ARCHITECT AND ENGINEER. 3.0 SHEET METAL WORK: 3.1 EXCEPT AS OTHERWISE SHOWN OR NOTED, ALL DUCTWORK AND OTHER SHEET METAL WORK SHALL BE GALVANIZED SHEET STEEL AND SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION, INC. DUCT CONSTRUCTION STANDARDS, PRESSURE CLASSIFICATION 2 IN. W.G. 3.2 VOLUME DAMPERS: GALVANIZED STEEL, PER SMACNA "LOW VELOCITY MANUAL," EXCEPT PROVIDE BEARING AT ONE END OF DAMPER ROD AND QUADRANT, WITH LEVER AND LOCKSCREW AT OTHER END. FOR INSULATED DUCTS, QUADRANTS MOUNTED OH COLLAR TO CLEAR INSULATION. INSTALL WITH LEVERS ACCESSIBLE., 3.3 ACCESS DOORS: INSULATED OR UNINSULATED, SAME AS DUCT 1) PROVIDE MINIMUM 20 IN X 14 IN. ON MAIN DUCTS, AND 12IN. X 6 IN. ON BRANCH DUCTS, UNLESS OTHERWISE APPROVED, AT FIRE DAMPERS, AND AT ALL DUCT ACCESSORIES SUCH AS HUMIDIFIERS, DUCT SMOKE DETECTORS, AUTO DAMPERS, AND LOUVERS. 2) ALL ACCESS DOORS TO BE HINGED, WITH LATCH SIMILARTO VENTLOCK NO. 100. 3.4 FLEXIBLE CONNECTIONS: NEOPRENE - COATED GLASS FABRIC, 30 OZ PER SQ YD WITH SEWED AND CEMENTED SEAMS, SIMILAR TO VENT FABRICS. PROVIDE WITH METAL COLLARS. ALLOW MINIMUM MOVEMENT OF 1 IN. 3.5 TURNING VANES: GALVANIZED STEEL SMALL DOUBLE - THICKNESS VANES WITH 2 IN. INSIDE RADIUS. 3.6 FIRE DAMPERS: UL LISTED, GALVANIZED STEEL CONSTRUCTION, MULTIBLADED TYPE, SPRING LOADED, EQUIPPED WITH FUSIBLE LINK, CONFORMING TO NFPA STANDARD 90A. SIMILAR TO AIR BALANCE MODEL 319 -P, RATED AS REQUIRED. SEE INSTALLATION ON DRAWING. 3.7 ALL DUCT DIMENSIONS INDICATED ON PLANS ARE INSIDE CLEAR DIMENSIONS. 3.8AUTOMATIC DAMPERS: COMPLETE WITH LINKAGE AND ELECTRIC OPERATOR. OPPOSED BLADE DAMPER OR GALVANIZED STEEL MIN. 4 IN., MAX. 8:IN. WIDE WITH COMPRESSIBLE EDGE SEALS TO PREVENT LEAKAGE. FACTORY - ASSEMBLE STEEL LINKAGE AND SHAFT WITH NYLON OR OIL - IMPREGNATED BRONZE BEARINGS. MOTOR WITH SUFFICIENT POWER TO LIMIT LEAKAGE TO 10 CFM PER SQ FT. LINKAGE TO WITHSTAND LOAD EQUAL TO TWICE MAXIMUM OPERATING FORCE WITHOUT DEFLECTION. DAMPER MOUNTED IN WELDED STEEL CHANNEL FRAME. 3.9 ALUMINUM DUCTWORK: ALL OUTSIDE AIR, EXHAUST, AND RELIEF DUCTWORK WITHIN 5 FT OF LOUVERS SHALL BE ALUMINUM WITH SEAMS SEALED WATERTIGHTWITH ALCOAALUMINASTIC TYPE C SEAM SEALER OR SOLDER. PITCH DUCTWORK TOWARDS LOUVER. 3.10 WIRE MESH SCREEN (WMS): NO. 16 USSG, 3/4 SQUARE MESH, IN 1 IN. WIDE GALVANIZED STEEL ENCLOSING FRAME. FLANGED DUCT OPENING TO RECEIVE FRAME. 3.11 LOW PRESSURE FLEXIBLE DUCT: SHALL BE A FACTORY FABRICATED HIGH TEMPERATURE COPOLYMER IMPREGNATED GLASS FABRIC, LOCKED TO COLD ROLLED FLAT STEEL SPIRAL. SIMILAR TO WIREMOLD 57. MAXIMUM INSTALLED LENGTH SHALL NOT EXCEED 18 IN. 3.12 COMBINATION FIRE AND SMOKE DAMPERS: UL LISTED, GALVANIZED STEEL. CONSTRUCTION MULTI- BLADED TYPE. EQUIPPED WITH FUSIBLE LINK CONFORMING TO NFPA STANDARD 90A. SIMILAR TO RUSKIN MODEL FSD60.. 4.0 AIR OUTLETS: 4.1 GENERAL: 1) MARGIN TYPES, COLORS, FINISH AND METHODS OF ATTACHMENT FOR ALL DIFFUSERS, GRILLES AND REGISTERS SHALL BE COORDINATED WITH ARCHITECTURAL CEILING AND WALL DETAILS AND SPECIFICATIONS. 2) FRAME TYPE SUITABLE FOR MOUNTING IN CEILING OR WALL CONSTRUCTION AS INDICATED ON ARCHITECTURAL PLANS. 3) EXACT LOCATION OF ALL AIR OUTLETS AS PER ARCHITECTURAL PLANS. 4) SUITABLE FOR OPERATION AT 20% EXCESS AND 20% LESS THAN NOTED CAPACITY FOR CONSTANT VOLUME SYSTEMS AND AT 20% EXCESS AND 60% LESS THAN NOTED CAPACITY FOR VARIABLE VOLUME SYSTEMS. MANUFACTURER RESPONSIBLE FOR EXAMINING AN APPLICATION OF EACH OUTLET AND GUARANTEE THAT EACH WILL PROVIDE REQUIRED NC LEVELS AND COMFORT SPACE CONDITIONS WITHOUT DRAFTS THROUGHOUT OPERATING RANGE. . 5) ALL REGISTERS AND DIFFUSERS SHALL BE PROVIDED WITH OPPOSED BLADE VOLUME DAMPERS. DAMPER OPERATING LEVERS SHALL BE ACCESSIBLE AT THE FACE OF AIR OUTLETS. 42 DIFFUSERS: DIFFUSERS SHALL BE STEEL CONSTRUCTION PAINTED WHITE SIMILAR TO TITUS TYPE SUITABLE FOR THE TYPE OF CEILING. ALL CEILING DIFFUSERS SHALL BE PROVIDED WITH VOLUME DAMPER. 4.3 REGISTERS AND GRILLES: 1) RETURN AND EXHAUST REGISTERS: STEEL CONSTRUCTION WITH VOLUME DAMPER AS PER MECHANICAL SCHEDULE. 5.0 NOISE CONTROL: 5.1 ALL ROOM NC LEVELS SHALL BE MAXIMUM NC-40. 5.2 PROVIDE SOUNDLINING FOR THE FOLLOWING DUCTWORK:' 1) ALL DUCTWORK NOT LESS THAN 20 FT ON EACH SIDE OF ALL FANS AND AC UNITS. 2) ALSO WHERE NOTED ON A DRAWING. 5.3 SOUNDLINING IN DUCTWORK: FIBROUS GLASS, MINIMUM 3 LB DENSITY, 1 IN. THICKNESS; MAXIMUM 0.25 K FACTOR AT 75 DEG F MEAN TEMPERATURE WITH ACRYLIC COATED FINISH FACTORY APPLIED EDGE COATING AND STENCILED IN ACCORDANCE WITH NFPA 90. FLAMESPREAD SHALL BE A MAXIMUM OF 25. LINING SHALL NOT SUPPORT MICROBIAL GROWTH AND SHALL BE TESTED IN ACCORDANCE WITH ASTM C 1071 AND ASTM G211G22. SIMILAR TO MANVILLE PERMACOTE LINA COUSTIC. 5.4 ALL SOUNDLINING, ADHESIVES, FACES AND ACCESSORIES TO BE APPLIED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, EXCEPT AS OTHERWISE NOTED. 6.0 TESTING AND BALANCING: 6.1 AIR BALANCING SHALL BE ACCOMPLISHED BY ADJUSTMENT OF FANS AND BRANCH DAMPERS FOR MAJOR ADJUSTMENTS. ADJUSTMENT OF TERMINAL DAMPERS AND DEVICES SHALL BE FOR TRIM OR MINOR ADJUSTMENT ONLY. THIS SHALL BE DONE TO PERMIT THE LEAST NOISE GENERATION IN THE TERMINAL AREAS AND UTILIZE MINIMUM FAN ENERGY. 6.2 UPON COMPLETION OF THE INSTALLATION, THE CONTRACTOR SHALL REBALANCE ANY EXISTING PORTIONS OF AIR DISTRIBUTION SYSTEM AFFECTED BY THE RENOVATION AND ALSO BALANCE ALL NEW WORK. 6.3 THE CONTRACTOR SHALL PROVIDE ALL LABOR, PRESSURE GAUGES, FLOW METERS, SHEAVES, AND BELTS REQUIRED TO BALANCE THE SYSTEMS. 6.4 BALANCING REPORT SHALL BE PROVIDED ON AABC -TYPE FORNS. 6.5 FANS AND AIR HANDLING UNITS SHALL BE BALANCED TO WITHIN +5% OF THEIR DESIGN CAPACITIES. ALL OTHER AIR AND WATER QUANTITIES SHALL BE BALANCED TO WITHIN +10% OF THE DESIGN QUANTITIES. 6.6 BALANCING AND TESTING SHALL BE PERFORMED AND SUPERVISED BY AN INDEPENDENT FIRM SPECIALIZING IN TESTING AND BALANCING. THE CITY INSPECTOR SHALL RECEIVE A COPY OF THE CERTIFIED AIR BALANCE REPORT PRIOR TO THE ISSUE OF CERTIFICATE OF OCCUPANCY. 6.7 THE PERFORMANCE AND CAPACITY OF ALL SYSTEMS AND EQUIPMENT TO BE DEMONSTRATED BY THE CONTRACTOR. 7.0 INSULATION - GENERAL REQUIREMENTS: 7.1 ALL INSULATION MATERIALS, INCLUDING JACKETS, FACING, ADHESIVE, COATINGS, AND ACCESSORIES ARE TO BE FIRE HAZARD RATED AND LISTED BY UNDERWRITERS LABORATORIES, INC. USING STEINER TUNNEL TEST METHOD FOR FIRE HAZARD CLASSIFICATION OF BUILDING MATERIALS, STANDARD UL 723 (ASTM E- 84),(ASA A2.5- 1963). FLAMESPREAD: MAXIMUM 25. FUEL CONTRIBUTED AND SMOKE DEVELOPED: MAXIMUM 50. FLAMEPRCOFING TREATMENTS SUBJECT TO DETERIORATION FROM MOISTURE OR HUMIDITY ARE NOT ACCEPTABLE 7.0 INSULATION - GENERAL REQUIREMENTS CONTINUED: 7.2 DEFINITIONS: 1) EXPOSED: INDOOR DUCTS, PIPING OR EQUIPMENT LOCATED IN MECHANICAL EQUIPMENT ROOMS AND IN AREAS WHICH WILL BE VISIBLE WITHOUT REMOVING CEILINGS OR OPENING ACCESS PANELS. 2) CONCEALED: INDOOR DUCTS, PIPING OR EQUIPMENT, WHICH IS NOT EXPOSED. 3) OUTDOOR: DUCTS, PIPING OR EQUIPMENT, WHICH IS EXPOSED TO THE WEATHER. 8.0 DUCTWORK INSULATION: 8.1 INSULATE ALL DUCTWORK IN ACCORDANCE WITH INSULATION SCHEDULE EXCEPT AS OTHERWISE NOTED. 1) SUPPLY /RETURN - CONCEALED - 1" THICKNESS - D1 MATERIAL - VAPORSEAL FINISH 2) SUPPLY /RETURN - EXPOSED - 1" THICKNESS - D2 MATERIAL - VAPORSEAL FINISH 8.2 NON - INSULATED DUCTWORK: 1) WHERE SOUNDLINING IS OF MINIMUM THICKNESS SPECIFIED FOR INSULATION. 8.3 MATERIAL: 1) TYPE D -1: MINIMUM 1 -LB DENSITY FIBERGLASS BLANKET, MAXIMUM 0.28 K- FACTOR AT 75 DEG F MEAN TEMPERATURE WITH FACTORY - APPLIED FOIL -SKRIM -KRAFT FACING SIMILAR TO MANVILLE MICROLITE. 2) TYPE D -2: 3. LB. FIBERGLASS BOARD. THE MAXIMUM K FACTOR SHALL BE 0.23 AT 75 DEG F MEAN TEMPERATURE WITH A MINIMUM DENSITY OF 3 LB. THE INSULATION SHALL BE PROVIDED WITH A FACTORY - APPLIED ALL PURPOSE OR ALL SERVICE FACING. THE INSULATION SHALL BE EQUAL TO MANVILLE TYPE 814 SPIN -GLAS AP. 8.4 INSTALLATION: 1). FIBERGLASS BLANKET: 2 IN. LAP STRIPS AT ALL SEAMS. SECURE BOTTOM OF ALL DUCTS OVER 24 IN. WIDE WITH MIN. 2 ROWS OF WELD PINS 12 IN. ON CENTER. SECURE ALL SEAMS WITH FOIL VAPOR BARRIER TAPE AND VAPORSEAL ADHESIVE. 2) FIBERGLASS BOARD: SEAL JOINTS AND BREAKS IN FACING WITH 3 IN. WIDE TAPE TO MATCH FACING AND ADHERE WITH VAPOR SEAL ADHESIVE. APPLY 5 IN. WIDE TAPE AT CORNERS, WELD PINS ON TOP, SIDES AND BOTTOM. 8.5 INSTALLATION: 1) BEFORE APPLYING INSULATION ALL PRESSURE AND LEAK TESTS SHALL BE COMPLETED AND APPROVED. 2) ALL INSULATION SHALL BE BUTTED FIRMLY TOGETHER. PROVIDE 2 IN. LAMP STRIPS AT ALL SEAMS SECURED WITH ADHESIVE. USE VAPOR BARRIER TAPE AND VAPORSEAL ADHESIVE WHERE REQUIRED. STAPLES NOT PERMITTED. 3) ALL INSULATION AND VAPOR BARRIERS SHALL BE CONTINUOUS PASSING THROUGH SLEEVES, HANGERS, ETC., OR OTHER OPENINGS. PROVIDE SADDLES OR SHIELDS FOR PROTECTION. 4) INSULATION FOR STRAINERS OR OTHER FITTINGS OR ACCESSORIES REQUIRING SERVICING OR INSPECTION SHALL HAVE INSULATION REMOVABLE AND REPLACEABLE WITHOUT DAMAGE. 9.0 VIBRATION ISOLATION SYSTEMS: 9.1 GENERAL: 1) PROVIDE ISOLATION FOR EQUIPMENT, PIPING AND DUCTWORK. 2) INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 3) PROVIDE LEVELING DEVICES AND APPROVED RESILIENT RESTRAINING DEVICES AS REQUIRED TO LIMIT EQUIPMENT AND PIPING MOTION IN EXCESS OF 1/4 IN. 4) ACCEPTABLE MANUFACTURERS: 9.2 MASON INDUSTRIES, INC. 9.3 VIBRATION ELIMINATOR CO. 9.4 KORFUND DYNAMICS CORP. 10.0 MOTORS: 10.1 MOTORS (UNDER HVAC WORK): IN ACCORDANCE WITH NEMA, IEEE AND ANSI C50 STANDARDS: 1) STANDARD EFFICIENCY UNLESS OTHERWISE NOTED. 2) 1.15 SERVICE FACTOR. 3) SQUIRREL CAGE INDUCTION, OPEN DRIPPROOF TYPE, 1750 RPM, NEMA TYPE B INSULATION CLASS, CONTINUOUS DUTY, EXCEPT AS NOTED. 11.0 MOTOR CONTROLLERS: 11.1 PROVIDED BY HVAC CONTRACTOR AND INSTALLED AND WIRED BY ELECTRICAL CONTRACTOR. 11.2 NEMA ENCLOSURE, WEATHERPROOF WHERE MOUNTED OUTDOORS. 11.3 WITH OVERLOAD PROTECTION. COORDINATE ALL MOTOR CONTROLLER TYPES AND SIZES WITH MOTOR TYPES AND SIZES. 11.4 1/3 HP AND SMALLER: PROVIDE MANUAL STARTER EXCEPT USE MAGNETIC TYPE WHERE AUTOMATICALLY CONTROLLED. 1) MANUAL TYPE: 2-POLE TOGGLE SWITCH WITH OVERLOAD PROTECTION AND PILOT LIGHT. 11.5 1/2 HP AND LARGER: PROVIDE MAGNETIC STARTER: 1) COMBINATION UNFUSED DISCONNECT SWITCH AND MAGNETIC STARTER EXCEPT AS NOTED. 2) OVERLOAD PROTECTION IN EACH PHASE LEG WITH RESET IN ENCLOSURE. 3) HOA SELECTOR SWITCH FOR AUTOMATICALLY OPERATED MOTORS. SAFETY CONTROLS COMMON TO BOTH CONTROLS. 4) RED, GREEN AND AMBER PILOT LIGHTS. 5) SWITCHES: HORSE- POWER - RATED, EXTERNAL PADLOCKING TYPE. 6) HOLDING COILS: 10 WATT, 120 VOLT. 7) CONTACTS: MAIN LINE AND MINIMUM (2) - NORMALLY OPEN, (2) - NORMALLY CLOSED 10 AMP AUXILIARIES, IN ADDITION TO CONTACTS REQUIRED FOR CONTROLS SPECIFIED. 8) CONTROL TRANSFORMER: FOR MOTORS OVER 120 VOLTS, TO STEP DOWN CONTROL VOLTAGE TO 120 VOLTS; OF THE REQUIRED CAPACITY WITH FUSE AND GROUND CONNECTION ON VOLTAGE SIDE. 9) FUSES: SIMILAR TO BUSSMAN. 10) RELAYS: TO SUPPLEMENT AUXILIARY CONTACTS IN CONTROLLER. MINIMUM 10 WATT COIL AND TWO 10 AMP CONTACTS. 11) TERMINALS: SUITABLE FOR CONDUCTORS NOTED AND AS APPROVED. 11.6 ACCEPTABLE MANUFACTURERS: 1) CUTLER - HAMMER. 2) SQUARE D. 3) ALLEN BRADLEY. 12.0 EQUIPMENT: 12.1 PROVIDE AND INSTALL ALL EQUIPMENT AND ACCESSORIES OF THE SIZES AND CAPACITIES AS SCHEDULED AND AS INDICATED ON THE DRAWINGS AND IN ACCORDANCE WITH APPROVED SHOP DRAWINGS AND MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL MOTOR STARTERS AS REQUIRED; MOTOR STARTERS WILL BE INSTALLED BY THIS CONTRACTORS AND WIRED BY ELECTRICAL TRADE. . 2.2 CONTRACTOR 1S RESPONSIBLE FOR MAINTAING ALL REQUIRED CLEARANCES FOR SERVICING SEPARATE PERMIT AND MAINTENANCE. COORDINATE REQUIREMENTS WITH ALL TRADES. REQUIRED FOR: ❑ Mechanical I Electrical Plumbing Gas Piping City of Tukwila `y'NU DIVISION REVISIONS No changes shall bo made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEWD OR CODE COMPLIANCE APPROVED JUL 17 2012 PIT City of _ BUILDING ISION ila FILE COPY Permit No., MGb'- PIan review approval is subject to errors and omissions. Approval of construction documents does not authclfae the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By Date: , 1 ? - City Oflbkwifa BUILDING DIVISION juQik ttVCITY aTUKWLA JUL 112012 PRMIT CENTER CORRECTION LT R# - TCBI 2007 COPYRIGHT NOTICE; These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. CONSULTING ENGINEER SEATTLE, WA 98188 0 0 MECHANICAL SPECIFICATIONS DATE: 5 -18 -2012 SHEET: SCALE: DRAWN BY: 6 PROJECT No.: TG81200'1 M1.0 GENERAL NOTES 1. THE GENERAL CONTRACTOR SHALL INSTALL BLOCKING OR FRAME ROOF OPENINGS AS SHOWN FOR ALL HVAG EQUIPMENT AND EXHAUST FANS. 2. INSTALLATION SHALL CONFORM TO THE ENERGY CONSERVATION DESIGN MANUAL STANDARDS FOR NEW NON- RESIDENTIAL BUILDINGS. 5. ALL WORK AND MATERIALS SHALL COMPLY WITH GOVERNING CODES, SAFETY ORDERS AND REGULATIONS. 4. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS, FEES AND INSPECTIONS REQUIRED BY GOVERNING AUTHORITIES. 5. ALL MATERIALS AND EQUIPMENT PROVIDED AND OR INSTALLED SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR UNLESS OTHERWISE INDICATED, FROM THE DATE OF FINAL ACCEPTANCE OF THE WORK BY THE DINNER. ANY DEFECTIVE MATERIALS OR INFERIOR WORKMANSHIP SHALL BE CORRECTED TO THE ENTIRE SATISFACTION OF THE OWNER. 6. FLEXIBLE DUCT SHALL INSULATED WITH ACOUSTICAL VINYL VAPOR BARRIER (U.L. APPROVED). MAXIMUM LENGTH NOT TO EXCEED 5' -0 ". DUCT SHALL BE CONNECTED TO TRUNK OR BRANCH DUCT WITH SHEET METAL SCREWS. HANGER STRIPS SHALL BE MINIMUM I" x BO ga. 1. CONGEALED CONDITIONED SUPPLY AND RETURN AIR DUCTS SHALL BE INSULATED WITH I -I/2" THICK .015 POUND DENSITY GLASS FIBER DUCT WRAP WITH REFLECTIVE VAPOR SEAL FASTENED TO DUCTWORK WITH 16 GAUGE SOFT ANNEALED WIRE SPACED AT 12" ON CENTER. SPACING TO BE 5" ON CENTER FOR FITTINGS. 5. ALL SHEET METAL DUCTWORK SHALL BE INSULATED IN ACCORDANCE WITH SMACNA AND OR LOCAL AND ASHRAE CODES. TAPE ALL TRANSVERSE AND LONGITUDINAL JOINTS AND TAKE OFFS ON SUPPLY, RETURN AND EXHAUST DUCTS. DUCT SHALL BE MILD GALVANIZED STEEL IN ACCORDANCE WITH SMAGNA STANDARDS (EXCEPT EXHAUST HOOD). CONTRACTOR TO FAMILIARIZE HIMSELF WITH THE SITE AND VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION AND ADJUST FOR ACTUAL FIELD CONDITIONS AT NO EXPENSE TO OWNER. REPORT TO THE ARCHITECT AND OR ENGINEER ANY DISCREPANCIES WITH THE PLANS AND EXISTING CONDITIONS. 10. ALL DUCTWORK, HANGERS, PAMPER CONSTRUCTION, SEAMS, INSTALLATION, ETC., SHALL CONFORM TO THE STANDARDS AS ADOPTED BY A.S.H.R.A.E. 8 SMAGNA. ALL WORK SHALL CONFORM TO ALL APPLICABLE LAWS, RULES REGULATIONS 4 RECOMMENDATIONS OF LOCAL BUILDING DEPARTMENT, NATIONAL BOARD OF FIRE UNDERWRITERS, N.F.P.A., 4 SHOPPING CENTER GENERAL SPECIFICATIONS. ALL DUCTWORK SHALL BE SHEETMETAL CONFORMING TO SMAGNA STANDARDS FOR LOW PRESSURE DUCTWORK 4 A.S.H.R.A.E. STANDARD 1Q -'75. II. THE MECHANICAL CONTRACTOR SHOULD FURNISH, CONNECT AND INSTALL THE THERMOSTAT /CONTROL WIRING AND THE ELECTRICAL CONTRACTOR SHOULD PROVIDE, INSTALL AND CONNECT THE ELECTRIC TO THE UNITS. 12. SCHEDULE OF WORK: THIS CONTRACTOR SHALL 15E REQUIRED TO FAMILIARIZE HIMSELF WITH THE PROPOSED WORK SCHEDULE 4 SHALL COORDINATE HIS WORK SCHEDULE WITH THE OTHER TRADES, 50 THAT WORK PROGRESSES CAN BE PLANNED IN A PROPER SYSTEMATIC FASHION TO AVOID ANY DUPLICATION OF EFFORT 4 RESULTANT DELAY OF PROJECT. 15. CONTRACTOR SHALL PROVIDE OPERABLE H 4 V SYSTEMS COMPLETE IN ALL RESPECTS AS CONTEMPLATED BY THE INFORMATION INDICATED ON THE DRAWINGS. IT IS NOT INTENDED THAT THE DRAWINGS 4 SPECIFICATIONS INDICATE EACH 4 EVERY ITEM OF INFORMATION NECESSARY FOR COMPLETE SYSTEMS BUT INDICATE SUFFICIENT INFORMATION FOR THE CONTRACTOR TO SECURE ADDITIONAL INFORMATION FROM OTHER SOURCES 4 PROVIDE ALL MATERIALS, EQUIPMENT 4 LABOR NECESSARY FOR COMPLETE INSTALLATIONS. 14. PROVIDE ARCHITECT WITH THREE (B) COPIES OF AIR BALANCE REPORT. INSTRUCT OWNER IN USE OF EQUIPMENT. AIR BALANCE REPORT TO BE AN INDEPENDENT TESTING AGENCY. AIR BALANCE TEST REPORT TO BE TAKEN IN THE LATE AFTERNOON WITH THE FOLLOWING TEMPERATURE READINGS DOCUMENTED (IN ADDITION TO GFM) I.) TEMPERATURE OF AIR LEAVING EACH CEILING DIFFUSER, 2.) TEMPERATURE OF AIR LEAVING HVAG UNIT, 5.) TEMPERATURE OF OUTSIDE AIR AT HVAG UNIT, 4.) TEMPERATURE OF AIR WITHIN SALES AREA (AT THERMOSTAT). 15. CONTRACTOR SHALL COORDINATE INSTALLATION OF ALL DUCTWORK WITH CEILING AND ROOF FRAMING, COOPERATE WITH OTHER TRADES, MAINTAIN MANUFACTURERS RECOMMENDED CLEARANCES OF ALL ITEMS AND EQUIPMENT, INSTALL TURNING VANES IN ALL a!O DEG ELBOWS, INSTALL SPIN -IN EXTRACTOR/DAMPER AT BRANCH DUCT CONNECTION TO MAIN DUCT AND DEAL AIR TIGHT. 16. CONTRACTOR TO INSTALL PRECHARGED REFRIGERANT LINES FROM FAN COIL TO CONDENSER ON ROOF. 11. ALL SUPPLY AND RETURN AIR DUCT DIMENSIONS ARE INSIDE CLEAR. I. CONTRACTOR TO PROVIDE AND INSTALL FLUE GAS EXHAUST VENT FOR WATER HEATER. VAV BOX SCHEDULE MARK VAV MANUFACTURER CARRIER MODEL NUMBER 55E INLET DIAMETER 6" GFM SET POINT 450 VAV ELEC. (VOLT) 120 ELEC. HEAT (KW - VOLT /PH) N/A GFM (MAXIMUM) 515 GFM (MINIMUM) 8q NOTE: COORDINATE ALL CONTROLS WITH LANDLORD, T.G.G. 15 TO PROVIDE ALL CONTROLS AND COMPONENTS REQUIRED FOR A FULLY FUNCTIONAL HVAG SYSTEM. VERIFY CONTROL REQUIREMENTS PRIOR TO ORDERING VAV BOXES. 1 AIR DEVICE SCHEDULE MARK SYMBOL MANUFACTURER CATALOG NUMBER FIXTURE DESCRIPTION NECK SIZE REMARKS 51 REQUIRED O.A. GFM ///"""" \ KITCHEN TITUS PAS 24x24 SUPPLY GRILLE SEE PLAN LAY -IN ACT. CEILING S2 E )/// ����� \„ 53 TITUS PA5 24x24 SUPPLY GRILLE SEE PLAN GYP. BOARD CEILING 53 10 CONDENSING UNIT `�, TITUS PA5 12x12 SUPPLY GRILLE SEE FLAN GYP. BOARD CEILING i>! DRINKING FOUNTAIN RI MOTORIZED DAMPER \ \\ R DIAMETER. TITUS PAR 24x24 RETURN GRILLE __ LAY -1N ACT. CEILING R2 EF ` 1— TITUS PAR 24x24 RETURN GRILLE -- GYP. SOAR, CEILING R3 FLOOR GLEAN OUT TITUS 50F 12x12 RETURN GRILLE -- -- R4 = TITUS 55RL LOUVERED GRILLE I5xI2 -- NOTE: I. ALL GRILLES IN GYP BOARD CEILING SHALL BE ORDERED WITH BALANCING DAMPERS VENTILATION REQUIREMENT CALCULATION PER IMG -200 t TABLE 4.3 ROOM NAME UNIT SERVICING PEOPLE PER 1000 SOFT arm/ PERSON GFM / SF AREA (SOFT) PEOPLE x GFM /PERSON SF x GFM /SF REQUIRED O.A. GFM PROVIDED O.A. GFM KITCHEN VAV -I 10 10 0.12 ISI 2 X 10 = 20 ISI x 0.18 = 33 53 10 MINIMUM FRESH AIR GFM REQUIRED PER CODE AIR VOLUME - CUBIC FEET / MINUTE 55 TOTAL OF ALL FRESH AIR INTRODUCED INTO SPACE TURNING VANES 10 LL SUPPLY AIR 15 MAINTAINED AT 20% OUTSIDE AIR. TENANT VAV 15 SET TO 450 CFM PROVIDING 10 GFM OF FRESH AIR TO THE SPACE. 1 MECHANICAL SYMBOLS LEGEND ABBREVIATIONS ASUPPLY GRILLE AS SPECIFIED A.F.F. ABOVE FINISHED FLOOR \ RETURN GRILLE AS SPECIFIED AHU AIR HANDLER UNIT SIDEWALL SUPPLY GRILLE AS SPECIFIED CD CONDENSATE DRAIN w- - -� -� FLOW ARROW GFM AIR VOLUME - CUBIC FEET / MINUTE TURNING VANES GU CONDENSING UNIT `�, EXHAUST DUCT THROUGH ROOF GW GOLD WATER ---1 VOLUME DAMPER DF DRINKING FOUNTAIN MD MOTORIZED DAMPER PIA R DIAMETER. �D FIRE PAMPER EPH ELECTRIC DUCT HEATER OTHERMOSTAT EF EXHAUST FAN 1— ELECTRIC DUCT HEATER ESP EXTERNAL STATIC PRESSURE l_!" PUMP FGO FLOOR GLEAN OUT ODUCT MOUNTED SMOKE DETECTOR FP FLOOR DRAIN REMOTE ALARM FOR DUCT DETECTOR ACTIVATION FLA FULL LOAD AMPS 21 EXHAUST FAN GPM GALLONS / MINUTE ,/ REMOTE TEMPERATURE SENSOR HP HORSEPOWER ' J MOTOR HW HOT WATER r---i. RECTANGULAR DUCT BREAK/GONTINUATION IWH INSTANTANEOUS WATER HEATER ROUND DUCT BREAK /CONTINUATION LAV LAVATORY 0 4 DDUCT TRANSITION LL LANDLORD # x # DUCT DIMENSIONS - WIDTH x HEIGHT MCA MINIMUM CIRCUIT AMPACITY (=it }GRILLE TYPE SUPPLY /RETURN GRILLE TAG GPM MD MOTORIZED DAMPER MOP MAXIMUM OVERGURRENT PROTECTION PLUMBING SYMBOLS LEGEND N.I.G. NOT IN CONTRACT L BALL VALVE NTS NOT TO SCALE GATE VALVE OA OUTSIDE AIR CHECK VALVE RA RETURN AIR 2 -WAY CONTROL VALVE RTU ROOF TOP UNIT It 3 -WAY CONTROL VALVE SA SUPPLY AIR Ili PIPE UNION SS SANITARY SEWER [ END GAP TEN TENANT 01 PIPE TURN UP T.G.G. TENANT (GENERAL CONTRACTOR C 1 PIPE TURN DOWN T -STAT THERMOSTAT FLOOR DRAIN TYP TYPICAL 0 SANITARY WASTE LINE UH UNIT HEATER t- ---- -; GOLD WATER LINE U.N.O. UNLESS NOTED OTHERWISE HOT WATER LINE VD VOLUME DAMPER Z Z i-- —f` VENT LINE V.I.F. VERIFY IN FIELD H.- 6 —i GAS LINE NC WATER CLOSET —GW -1 GREASE WASTE LINE NCO WALL GLEAN OUT u u TANK TYPE WATER HEATER WH TANK TYPE WATER HEATER NOT NOT ALL SYMBOLS OR ABBREVIATIONS MAY APPEAR ON PLANS. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2012 City of Tukwila BUILDING DIVISION IS -082- R)rG. ti:11..�l�i1, CITY OFTUIvi11LA JUL 112012 PERMIT CENTER TCB12007 COPYRIGHT NOTICE; These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. SEATTLE, WA 98188 111111.111/..%k :C:t3 miwU SP)1)3 0 NI C CONSULTING ENGINEER 0 v1 z 0 H te -10 -I2 GIN COMMENTS n la 0. E v J E J 0 W 0 a . 1C o 0 z c>: N 1".. V (0 C 0) N�� • co u N to 0 0 0 t v Z Chi co el o co 3 .4. F▪ �- DATE: 5- I5-2OI2 SHEET: SCALE: I/4"= DRAWN BY: AM PROJECT No.: TGB12O0.7 M1.1 THREADED ROD METAL JOIST 1" X I/8" MIN (DUCTS OVER 2 SQ. FT.) I" X 1/16" MIN (DUCTS UNDER 2 SQ. FT.) FOR DUCTS OVER 49" WIDE, TURN METAL STRAP UNDER BOTTOM OF DUCT AND FASTEN MAX. SIDE INCHES THROUGH 12 I3 THROUGH 30 31 THROUGH 54 55 THROUGH 84 OVER 84 RECTANGULAR DUCTS MIN. 6ALV. BHT. GAUGE 26 (0.022 IN. ) 24 (0.028 IN. ) 22 (0.034 IN. ) 20 (0.040 IN. ) 18 (0.052 114. ) ALUMINUM MIN. B 4 S GAUGE 24 (0.020 IN. ) 22 (0.025 IN. ) 20 (0.032 IN. ) 18 (0.040 IN. ) 16. (0.051 IN. ) DUCT SUPPORT DETAIL 2" WIDE MIN. DUCT STRAP 48" O.G. MAX. RIGID ROUND METAL DUCT EXTERNALLY INSULATED SCALE: N.T.S. SELF TAPPING SCREWS RIGID ROUND DUCT ELBOW EXTERNALLY INSULATED INSULATED FLEXIBLE DUCT MAX. LENGTH 5' -0" VOLUME DAMPER (FOR FINAL BALANCE ADJUSTMENT) DIFFUSER TRIM FRAME ALL DUCT LINER TRANSVERSE EDGES TO SE COATED WITH ADHESIVE IN ACCORDANCE WITH SMAGNA STANDARDS (TYP.) METAL SUPPLY DUCT EXTERNALLY INSULATED DIFFUSER CEILING DIFFUSER CONNECTION DETAIL SCALE: N.T.S. KEYED NOTES 0 PROVIDE VAV AS SPECIFIED ON MI.I CONNECTED TO LL SUPPLY DUCT ABOVE ADJACENT TENANT. COORDINATE DUCT CONNECTION WITH LANDLORD AND ADJACENT TENANT. 0 PROVIDE THERMOSTAT AT 45" AFF. PROVIDE GONTROL5 COMPATIBLE WITH EXISTING LANDLORD SYSTEM. VERIFY PRIOR TO BID. COORDINATE FINAL LOCATION WITH OWNER /ARCH. OPROVIDE R.A. GRILLE FOR PLENUM RETURN TO LL SYSTEM. FLANGED AN 6ASKETED JOINT OR DUCT CONNECTION AND RE- INFORGEMENT IN ACCORDANCE WITH SMAGNA 2" W.G. GLASS, SEAL NON- GASKETED TRANS- VERSE JOINTS IN ACCORDANCE WITH SMAGNA GLASS "G" (TYP.) MAIN DUCT 1 I" ACOUSTICAL LINING 45 BRANCH DUCT -1 VOLUME DAMPER LOCATION W HERE ABOVE LAY -IN GEILIN6. P ROVIDE WITH LOCKING QUADRANT 18" LONG ORANGE MARKER TAPE ATTACHED TO PAMPER TO IDENTIFY LOCATION TYPICAL RECTANGULAR DUCT TAKE -OFF DETAIL SCALE: N.T.S. REMOTE MECHANICAL PLAN SCALE: 1/4"=1`-0" REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2012 City of Tukwila BUILDING DIVISION MECHANICAL PLAN SCALE: 1/4".-7,1'-0" i M082 RECENECk CITY OF TUKWILA JUL 11 2012 PERMIT CENTER TCB12007 COPYRIGHT NOTICE.; These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. 0) a .c V • M w Q p •72 ,41) 11 5 2 vi 0 14111i tlo' CONSULTING ENGINEER SEATTLE, WA 98188 "4-'15 ..C.`) a 0 a z O In to z .O v v (V i 0 t 1- cT- - co W E co - o N Af° = .Q u) 13 9 J z 4 tg 0 U N II to i— '' 0 YI is. V ^^ CO co CO g0 ok„ Q"r 1J CU r� '" N 0) 0) co DATE: SCALE: DRAWN BY: PROJECT No.: 5 -I8 -2012 SHEET: 1/4 "= I' -0" AM M2.1 TGB 1200'1