Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M12-084 - SEARS
SEARS 18350 OLYMPIC AV S M12 -084 City okukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 7888900155 18350 OLYMPIC AV S TUKW Project Name: SEARS Permit Number: M12 -084 Issue Date: 06/11/2012 Permit Expires On: 12/08/2012 Owner: Name: Address: Contact Person: Name: Address: Email: C/O EPROPERTYTAX INC DEPT #207 , PO BOX 4900 85261 JOFFRE SECHIER 3202 C ST NE , KENT WA 98002 JOFFRE @C OMFORTMECH. C OM Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P -105 , KENT, WA 98032 Contractor License No: COMFOMI015LA Phone: 425 251 -9840 Phone: 425- 251 -9840 Expiration Date: 04/25/2014 DESCRIPTION OF WORK: REPLACE (1) 3 -TON ROOFTOP H/P WITH 3 -TON H/P WITH ECONOMIZER. REPLACE (1) 3 -TON SPLIT H/P WITH RELOCATED 3 -TON PACKAGED H /P. Value of Mechanical: $12,950.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $342.81 International Mechanical Code Edition: 2009 Date: 6'4 1— 1.2- I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o the pthformance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this p Signature: Print Name: aT-C1-1/431-3Z_ Date: (Q—U—tL This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -084 Printed: 06 -11 -2012 • • PERMIT CONDITIONS Permit No. M12-084 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12-084 Printed: 06 -11 -2012 Site Address: • CITY OF TUKWILA Community Development Department Permit Center 6300 Soutlzcenter Blvd , Suite 100 Tukwila, W4 98188 http: / /www.TukwilaW A.gov Mechanical Permit No. !v, 12— Od Project No.-. Date Application Accepted: at 7, Date Application Expires: l'1 0 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** Ie3,cb pLrifrat Ave. co. Tenant Name: Stn.% King Co Assessor's Tax No.: 0 i el ' t« Suite Number: PROPERTY OWNER Name: C(t opt, U-1AZO EL Address: 2� `� �ZN� d, __ 8 City: Kcki- State: w4 Zip:98 2, CONTACT PERSON.— person receiving all project communication ^ Name: �inva c. &L a tli Address: 3r7 C s7 Ii G City: Kei, State: `L it Zip9soz, Phone(t2s „2s 69 4 Fax lesz_- 3eo—(os7099 Email: ""I'OFv.QE QcOMFc2.1. titec.4---:t1.0m New Tenant: loor: Yes ❑..No -MECHANICAL CONTRACTOR INFORMATION Company Name: CA1.1%17 HEW ANUIL. Address:371z S7 Kt: City: Au— IS ■-atst State: V14 4 Zip9800 Phone4z5.7r1_apcio FaxZS.3 :1_6s / 3 ConC el! ICU a.QOOts(J4 Ex S /24 (1 Tukwila Business License NE us _0%336s- CONTACT PERSON.— person receiving all project communication ^ Name: �inva c. &L a tli Address: 3r7 C s7 Ii G City: Kei, State: `L it Zip9soz, Phone(t2s „2s 69 4 Fax lesz_- 3eo—(os7099 Email: ""I'OFv.QE QcOMFc2.1. titec.4---:t1.0m New Tenant: loor: Yes ❑..No -MECHANICAL CONTRACTOR INFORMATION Company Name: CA1.1%17 HEW ANUIL. Address:371z S7 Kt: City: Au— IS ■-atst State: V14 4 Zip9800 Phone4z5.7r1_apcio FaxZS.3 :1_6s / 3 ConC el! ICU a.QOOts(J4 Ex S /24 (1 New Tenant: loor: Yes ❑..No -MECHANICAL CONTRACTOR INFORMATION Company Name: CA1.1%17 HEW ANUIL. Address:371z S7 Kt: City: Au— IS ■-atst State: V14 4 Zip9800 Phone4z5.7r1_apcio FaxZS.3 :1_6s / 3 ConC el! ICU a.QOOts(J4 Ex S /24 (1 Tukwila Business License NE us _0%336s- Valuation of project (contractor's bid price): $ ! 2) ()SO Describe the scope of work in detail: ?LACE c T t\i(q. 3=15v i- bP g \rte -r t4i 3-10q 1r1 Ct) LxasT2N Q 3=11)N SNP 4(1°' W i CEO 1R LSE D 3 1 t N PAcoRizo t-gp, Use: Residential: New Commercial: New Fuel Type: Electric ❑ ❑ Replacement E ❑ Replacement Gas El Other: H: \Applications \Forms - Applications On Line \20I I Applications \ Mechanical Permit Application Revised 8 -9 -1 I.docx Revised: August 201 I bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type::. Qty` Furnace <100k btu Furnace >100k btu Floor furnace Suspended /wall /floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty, Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu =PERMIT APPLICATION NOTES • Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: Print Name: Mailing Address: �i rJR UTHORIZED AGENT: (Q(142, Date: Day Telephone: 4 `Z5 [ —9 <1'6 Kt AvYivQN WA- 9 City State Zip H: \Applications \Forms- Applications On Line \2011 Applications \Mechanical Permit Application Revised 8.9.1 I.docx Revised: August 2011 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7888900155 Address: 18350 OLYMPIC AV S TUKW Suite No: Applicant: SEARS RECEIPT Permit Number: M12 -084 Status: APPROVED Applied Date: 06/01/2012 Issue Date: Receipt No.: R12 -01828 Initials: User ID: Payee: WER 1655 Payment Amount: $274.25 Payment Date: 06/11/2012 09:34 AM Balance: $0.00 JOFFRE SECHIER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 11113G ACCOUNT ITEM LIST: Description 274.25 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 274.25 Total: $274.25 doc: Receipt -06 Printed: 06 -11 -2012 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7888900155 Address: 18350 OLYMPIC AV S TUKW Suite No: Applicant: SEARS RECEIPT Permit Number: M12 -084 Status: PENDING Applied Date: 06/01/2012 Issue Date: Receipt No.: R12 -01761 Initials: User ID: Payee: JEM 1165 Payment Amount: $68.56 Payment Date: 06/01/2012 01:07 PM Balance: $274.25 JOFFRE T SECHIER, COMFORT MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 51107G ACCOUNT ITEM LIST: Description 68.56 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 68.56 Total: $68.56 doc: Receiot -06 Printed: 06 -01 -2012 • INSPECTION NO. INSPECTION RECORD Retain a copy with permit (v1r2- 08(1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 vg_. (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ,1 SE AIZS Type of Inspection: f-71 NJ AL, Address: , .t .9-N '' '5 0 NM tvl PO 11■./c. Date Called: f ill ' / NJ Special Instructions: ' g f /IS S (Id ? 4/./, ' r.-> / I 1 ,,r c*.) i Date Wantv: i 7/to . p.m, m.-. Requestdr: ., Phone No: ' r- Approved per applicable codes. Corrections required prior to approval. ,,7) COMMENTS: , f ill ' / NJ '''' Lc... 4 4' i-----T\.‘ / ..zt ./. V . , ... . , . , . . . , .. . .. . ' " ,:. .."-., ------- 4 :' --.......... Date: i t) I 1 INSPIICTION FEE REQUIRED. Prior t next inspection, fee must be aid at 300 Southcenter Blvd., Suite 100 Call to schedule reinspection. INSPECTION NO. 1 INSPECTION RECORD Retain a copy with permit "20641 PERMIT NO. '-CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ., (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: SeAPS Type of Inspection: f".: i1 Address: 3 S.5.6 ©.0 9 i PiC! Date Called: /; v Special Instructions: % Date Wanted:. 6 / la a n .m Requester: Phone No: . 2d6- 963 -38 &..7 "Approved per applicable codes. E Corrections required prior to approval. g COMMENTS: R NSPECTION FE REQUIR D. Prior to ne t inspection. fee must be id at 6300 Southcenter Blvd., uite 100. C -ll to schedule reinspection. M (k) Project: 18350 Sctr South Prepared By: 3T Pkg HP -SmII Pk 05/25/2012 10:15AM FILE COPY Permit No., 3T Pkg HP -SmII Pk Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet REVIEWED FOR CODE COMPLIANCE APPROVED JUN 072012 City of Tukwila BUILDING DIVISION \g1YRSYNM1A JUN 01 2012 PERMIT CENTER Packaged Rooftop Builder 1.29v Page 1 of M 14) CIA) ‘L-vo-1 Project: 18350 Sctr South Prepared By: Unit Report For 3T Pkg HP -Stull Pk 05/25/2012 10:15AM Unit Parameters Unit Model:_. 50EZ- A36 - - -3 Unit Size. 36 (3 Tons) Volts- Phase -Hertz 208 -1 -60 Heating Type. Heat Pump Duct Cfg. Vertical Supply / Vertical Return Warranty Information 1 year warranty on parts 5 year warranty on compressor Dimensions (ft. in.) & Weight (1b.)*** Unit Length. 4' 0.1875" Unit Width. Z 8.625" Unit Height' 3' 7.9375" * ** Weights and Dimensions are approximate. Weight does not include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Total Operating Weight 343 lb ADD for Economizer Weight = 65 Ibs ADD for Curb = 55 ibs No optional warranties were selected. NOTE: Please see Warranty Catalog 500 -089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50EZ- A36 - -3 Rooftop Unit 1 Accessories CPHEATER052A00 3.8/5.0 kW, 208/230 -1 -60 volt, Electric Heater 1 CPCRKHTROO8A00 240V Crankcase Heater 1 CPECOMZR007A00 Economizer 1 CPRFCURB011A00 14 inch Common Flat Roof Curb 1 CPRLYKIT001A00 Economizer relay kit for heat pumps 1 Packaged Rooftop Builder 1.29v Page 2 of 6 Project: 18350 Sctr South Prepared By: Certified Drawing for 3T Pkg HP -SmII Pk 05/25/2012 10:15AM 9-15/16 :252.01 4 31' 1/11 - 98.5 IHIIIHII IIIINI r. = '2-5/9 :829.:1 :3474 OITLET- 0.15(13.)1N.P.T. X 1.96722 'nD[Er LEFT SIDE VIEW 12-13 'E 1325.4: 3.5/8 192.11 (40009 COIL TOP VIEW 41 :1193.81 � 1 003P/F'S01� ' P NE_ 08 38) ' J. 918 4114 3 /5850- 0011E0 15945/86. N1 (1RRIER 11!71 1' M 3( 14W'N1 TS - qOq /4 41,7 . 1 )' !8:68 1,71 u1 I1 )6(18:161 1008 14 1 '8368 (30071:06 THAT 116 171 :841 811. NOT 6t 111'.1:1:1 08 1110 1:117: TAMER [7110841:WS 4111108 .001( 1 19(687/8 [7/811'4' 1A 1 r:). v[( 08 A( -6714 K[ : CE :7( il:l. • ./N1' EL-CTRICAt C41R1CTEP :S -ICS JAI- IT. TUT HEIGN' :N /M5' CEAIER OF .AAV:T' IA/VV L3 6G 5)E1-424.--31 208/23)-'-6) 32) .145.1 42-1/8 Hit '9 -3/4 5)7.1 '4 -3/0 5)EZ- A3) - -- 13/5:0 208/230 -5. 200/233.3-60 332 .151.1 42-1/8 IC /C '9 -3/4. 5)1.1 (4 -3 /4 3:4.' 5312-639 - -- 13'517 308;233-1. 238/231-3 -60 335 152.3 42.1/8 . 7171 '9-3/6. 5)1.1 '4 -3'4 374.• 5313- 635 - - -66 461 -3.60 350 '158.6 42.1/9 ' 107C :9-3/6( 531.1 '4 -3/4 351.' 465.4 405.4 406.4 4C6.4 SHIES :80.34 -C. CORNER WE :GN' 50E2- 424 - -30 .208/230'64.0.23.0 5'.2.23.2 76.• 34.8.12/.9 581 5007-83)---13/5 /0 1208/230.65.5'33.2 53.2,24.1 79.• 36.2 :132.9 60.3 -0EZ 436 :3/519 ) 208/2301E7.2'30.5 53.7:24.4 80.4 32.6 :134.3 61.0 50EZ- 636-- -63 : 460 :655.2:30.5 53.7124.4 89.6 4).'1139.3 63.2 A0-8: ALL 3A8:E DAi8 '3,18843 FOR AL' '40 -0'1 INSTALLED 0311095 180631 ((060072(8 - LECTR:CAL 46(555 P8811, 1 1 06 l 2 17 -'3/16 7325.41 7.'/4 1164.21 0 1 -3/4 :44.5 P1 :14. P..C. OWER (6163 43 3/16 1122 .0; -6L0WER P46EL FRONT VIEW 3/16 :4.81 3 -7116 (61.31 4.33/16 - CC 1/8' :(/8 6 HCLS 1'27 21 80818(1 EN -R RIGHT SIDE VIEW Ik000® CLEARANCES TD CU618USRO E NLAO- (40 /1S INN) 'OP OF 0411 14 1355.61 3017 SIDE OF (427 2 15).81 SIDE OPPOSITE D1C -5 14 7355.61 601.04 OF UNIT 0 11.0: (1ECT41C /L PANEL 36 1914.41 AEC. RP.ODRED 0.0ARANCES. BETWEEN ON :TS, POWER E918' SIDE JNI' AND 242 /3)ADED SURFACES. POWER E5TR1. SUE 9817 AND BLOCK OR CONCRETE WANES AV) OTHER GROUN5E0 098'8CES. POWER ENTRY SID' BEMIRED CLEARANCE FOR WERATION APD MIMING INCHES 0511 '056.91 36 914.01 44 "056.81 INCHES (1/91 E' /AP. COE7 ACCESS 57/8 36 1914.01 POWER EN-R• SIM 42 (1066.61 IE[CE'T FOP VEC 3100(004(875/ 967' -01. 48 11219.21 SIDE OPPOSITE 301/5 36 (914.01 DUCE PANEL 12 /394.315 84(8(908 D- a57AVCES:14 JAI/ IS PLR: ' LESS -N 8 .211:481 FROM W4L, S661E8,14E4 S'S-5N P1RF06VAVCE 4918E CONPAOVISE). DEN16S :095 IN 11 ARE TM NV 15.7/8 1403.71 6 -9/16 1166.11 3-7/15 181.31 SU'PLN CU(I /3/11766 8(1'349 DUCT 0011791- 9 -1/8 21 5/6 123) 81 :543.31 1250.8: 9 1/8 REAR VIEW [Alt 01.24/C9 SIVGLE ZONE ENE-ERIC COOL:NG A PEAT SM) 50= Z50357 irl 3.0. Packaged Rooftop Builder 1.29v Page 3 of 6 FORM NO. 7843 -2P SUBMITTED TO COMPANY. DRAWN BY T. HUBBARD JOB NAME - EQUIPMENT: NOTES: Small Curb for Carrier SPP Units with Sheet Metal Base Rails 48 /50ES, EZ, VL A24 -A36; 50GL, JZ A24 -A36; 48/50VT, XL, XT A24 -A30 Units Features: • Constructed of heavy gage galvanized steel. • Roofcurb ships knocked down. • Easy field assembly. • Insulated deck pan. • Gasketing package and hardware included. • Wood nailer provided. Part Number: CRB -SDSML ** Carrier Unit 48/50ES, EZ, VL A24 -A36; 50GL, JZ A24 -A36; - 48/50VT, XL, XT A24-A30 MicroMetl Curb No. CRB - SDSML -11 CRB - SDSML -14 CRB - SDSML -24 Carrier Curb No. CPRCURB010A00 CPRCURB011A00 D 11" N/A 14" 24" NOTE: For full insulated roofcurb, add CI to the end of the part number. NOTES: Do not use these curbs on unit without base rails. CORNER DETAIL SIDE VIEW DETAIL THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETCS WRITTEN CONSENT MICROMETL CORP. - 3035 NORTH SHADELAND AVENUE, SUITE 300 - INDIANAPOLIS, IN 46226 - 1- 800.662 -4622 - MICROMETL SPARKS - 905 SOUTHERN WAY - SPARKS. NV 89431 - 1- 800 -884 -4662 SUBMITTED TO COMPANY. DRAWN BY: T. HUBBARD JOB NAME: EQUIPMENT NOTES: Down Discharge Economizer with Filter Rack for Carrier 48 /50ES,EZ,VL 024- 036,A24 -A36; 48/50VT 024- 030,A24 -A30; 50GL,JZ 024- 036,A24 -A36 Units Part Number: ECD -SDSML ** Econo. Part No. ECD - SDSML- ADB -CD Controls Dry Bulb ECD -SDSML -ENT CD Enthalpy ECD - SDSML -NC -CD No Controls Supply air cover panel. Shipped on HVAC unit. Features- Economizer for down application only. • Fully assembled, easy to install. • 2" Filter rack and 1" TAW filters provided. • Rainhood ships assembled, includes a water entrainment filter and is constructed of prepaint steel. • Low leak outside air damper. • Barometric relief damper. Carrier Equivalent: CPECOMZR007A00 FILTER RACK SIZE 1" Filters (2) 12" x 20" x 1" 2 " Filters (1)10 "x20 "x2" (1)12 "x20 "x 2" NOTES: 1. Relays required for heat pump units can be field supplied or order Carrier Kit CPRLYKIT001A00. 2, Economizer should not be used on XL,XT INFINITY units. 3. Economizer includes harness extensional for older units with no economizer harness factory installed. 4. The "NC" economizer models do not include actuator, controller, sensors, or wiring harness. Coil 00 Replacement panel shipped with economizer (some newer units will include this panel) Panel for filter and controls access Economizer outside air damper Economizer's barometric relief damper 00 00 00 00 00 00 00 00 00 00 00 00 Filters provided Rainhood with water entrainment filter SIDE VIEW Down Discharge Aluminum water entrainment filter THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL•S WRITTEN CONSENT MICROMETL CORP. - 3035 NORTH SHADELAND AVENUE. SUITE 300 - INDIANAPOLIS, IN 48226 - 1.800662 -4822 - MICROMETL SPARKS -905 SOUTHERN WAY - SPARKS. NV 89431 - 1-800 -884 -4662 • Project: 18350 Sctr South Prepared By: Performance Summary For 3T Pkg HP -SmII Pk 05/25/2012 10:15AM Part Number:50EZ- A36 - - -3 ARI SEER. 13.50 Base Unit Dimensions Unit Length .......48.2 in Unit Width 32.6 in Unit Height .........43.9 in Total Operating Weight 343 lb + Economizer & Curb Unit Unit Voltage- Phase - Hertz. 208 -1 -60 . Air Discharge. Vertical Fan Drive Type. Direct Actual Airflow. 1227 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy 31.44 BTU /Ib Evaporator Leaving Air DB 60.0 F Evaporator Leaving Air WB. 58.1 F Evaporator Leaving Air Enthalpy 25.08 BTU /Ib Net Cooling Capacity 35.09 MBH Net Sensible Capacity 26.50 MBH Total Unit Power Input 3.05 kW Coil Bypass Factor 0.191 Heating Performance Outdoor Ambient Temperature. 47.0 F Entering Air Indoor Coil DB:..... 70.0 F Leaving Air Indoor Coil DB. 96.5 F Total Heating Capacity. 35.06 MBH Integrated Heating Capacity 35.06 MBH Heating Power Input 3.02 kW High Temperature COP' 3.4 Low Temperature COP' 2.3 HSPF. 7.7 Electric Heating Capacity 3.80 kW Unit Leaving Air Temp. 106.2 F Supply Fan External Static Pressure. 0.50 in wg Options / Accessories Static Pressure Electric Heaters. 0.06 in wg Economiser 0.25 in wg Wet Coil. 0.10 in wg Total External Static 0.91 in wg Fan RPM. 0 Fan Power 0.66 BHP Fan Motor Size, hp' 3/4 NOTE- Med -High Motor Speed, Vert Electrical Data Minimum Voltage. .197 Maximum Voltage: 253 Compressor RLA. 19.3 Compressor LRA 79 Packaged Rooftop Builder 1.29v Page 4 of 6 Project: 18350 Sctr South Prepared By: Performance Summary For 3T Pkg HP -SmII Pk 05/25/2012 10:15AM Actual Electric Heater kW. Electric Heater FLA' 3.8 18.1 Outdoor Fan FLA (ea)' 1.2 Indoor Fan Motor FLA' 6 Power Supply MCA. 54 Power Supply MOCP (Fuse or HACR) :..............._ 60 Acoustics Sound Rating. Sound Power Levels, db re 10E -12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 63.0 250 Hz NA NA 68.0 500 Hz NA NA 73.0 1000 Hz NA NA 71.0 2000 Hz NA NA 67.0 4000 Hz NA NA 62.0 8000 Hz NA NA 55.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver' 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction' 0.0 ft Detailed Acoustics Information 77.0 db Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k Overall 1. Sound Power Levels at Unit's Acoustic Center, Lw 0.0 63.0 68.0 73.0 71.0 67.0 62.0 55.0 76.8 Lw 2. A- Weighted Sound Power Levels at Units Acoustic Center, LwA - 26.2 46.9 59.4 69.8 71.0 68.2 63.0 53.9 75.0 LwA 3. Sound Pressure Levels at Specific Distance from Unit, Lp 0.0 30.6 35.6 40.6 38.6 34.6 29.6 22.6 44.4 Lp 4. A- Weighted Sound Pressure Levels at Specific Distance from Unit, LpA 0.0 30.6 35.6 40.6 38.6 34.6 29.6 22.6 44.4 LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.29v Page 5 of 6 CR) Z-vu-1- 50EZ —A Comfort' Single— Packaged Heat Pump System with Puron® (R -410A) Refrigerant Single— And Three —Phase Units 2 to 5 Nominal Tons (Sizes 24 -60) Product Data A09034 Fig. 1 - Unit 50EZ -A Single- Packaged Products with Energy- Saving Features and Puron® refrigerant. • Up to 13.5 SEER • Upto7.7HSPF • Upto11.5 EERat95 °F OD • Factory- Installed TXV • Multi -Speed High Efficiency DC Blower- Standard • Dehumidification Feature FEATURES /BENEFITS One -piece Heat Pump unit with optional electric heater, low installation cost, dependable performance and easy maintenance. Efficient operation High - efficiency design with SEERs (Seasonal Energy Efficiency Ratio) of up to 13.5. Puron Environmentally Sound Refrigerant is Carrier's unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. Puron refrigerant is in service in millions of systems, proving highly reliable, environmentally sound performance. Easy Installation Factory - assembled package is a compact, fully self- contained, heat pump unit that is prewired, pre - piped, and pre- charged for minimum installation expense. These units are available in a variety of standard capacity ranges with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Carrier Turn to the Experts. Innovative Unit Base Design On the inside a high -tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Durable, dependable components Compressors are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection. Direct -drive multi -speed brushless DC blower motor is standard on all 50EZ -A models. Direct - drive, PSC (Permanent Split Capacitor)condenser -fan motors are designed to help reduce energy consumption and provide for cooling operation down to 40 °F (4.4 °C) outdoor temperature. Motormaster® 11 low ambient kit is available as a field installed accessory. Thermostat controls designed to work as a system with Carrier's small packaged product. Thermostatic Expansion Valve - A hard shutoff, balance port TXV maintains a constant superheat at the evaporator exit (cooling cycle) resulting in higher overall system efficiency. Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier. High and Low Pressure Switches provide added reliability for the compressor. Indoor and Outdoor coils are computer- designed for optimum heat transfer and efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit. Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 74dBA. Easy to service cabinets provide easy 3 -panel accessibility to serviceable components during maintenance and installation. The base with integrated drain pan provides easy ground level installation with a mounting pad. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3 /4 -in. wide perimeter flange makes frame mounting on a rooftop easy. Convertible duct configuration Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes two horizontal duct covers. Downflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Cabinets are constructed of heavyduty, phosphated, zinc - coated prepainted steel capable of withstanding 500 hours in salt spray. Interior surfaces of the evaporator and electric heater compartments are insulated with cleanable semi -rigid insulation DESCRIPTION These packaged heat pumps are designed for outdoor instal- lation. Only utility and duct connections are required at the point of installation. Field- installed electric heater accessories are available to provide electric heat, if required. STANDARD FEATURES / BENEFITS OPERATING EFFICIENCY - All units provide high operating efficiencies of 10 SEER or greater, 3.0 COP or greater and up to 7.0 HSPF. All efficiencies exceed legislated minimum levels. ON SITE FLEXIBILITY - All model sizes share a common, compact design cabinet with a single footprint. The installer has the flexibility of setting one curb or pad and placing the proper tonnage unit on that curb after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibility and needs to carry less inventory. LOWER INSTALLATION COST - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof, plus, the installer can fit this unit between the wheel wells of full size pick -up truck. All models are well under 500 pounds. All units are completely wired, charged with R -22 and tested prior to shipment. Unique test stations using a new state of the art computerized process system are used to insure product quality. Refrigerant charge, and component part numbers are verified via computers at manufacturing point. Vital run test sta- 036- 21311 - 003 -A -0104 IYORK® TECHNICAL GUIDE Champion Series SINGLE PACKAGE HEAT PUMPS BHA018 THRU 060 1 -1/2 THRU 5 NOMINAL TONS 10 SEER tistics such as system pressure, motor currents, air velocity and temperature and unit vibration are monitored and recorded by the system to insure unit performance. Equal size, side supply and return duct connections allows easy hook -up of ducts to match low crawl spaces without tran- sition pieces. UTILITY CONNECTIONS MADE EASY - Electrical utility knockouts are provided through the bottom as well as the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field in- stalled electrical disconnect switch must be installed. CONVERTIBLE AIRFLOW DESIGN - The bottom duct open- ings are covered when they leave the factory ready to be used for a side supply / side return application. If a bottom supply / bot- tom retum application is desired, you simply remove the two panels from the bottom of the unit and place them in the side supply / side retum duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. CONDENSATE PAN - A non - corrosive, long- lasting, water -tight pan is positioned below the evaporator coil to collect and drain all condensate. Less collection of stagnate condensate will build- up. The condensate pan conforms to ASHRAE 62 -89 standards (Ventilation for Acceptable Indoor Air Quality). CONDENSATE DRAIN - The heavy duty, % inch NPTI copper connection is more tolerable during installation and is more durable over time. The connection is rigidly mounted to as- sure proper fit and leak tight seal. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE BACK AND BOTTO RETURN AIR AND SUPPLY AIR DUCT OPENING (.0 V.30 1 036 - 21311 - 003 -A -0104 DIRECT DRIVE CONDENSER FAN MOTOR HIGHLY EFFICIENT ENHANCED COPPER TUBE /ALUMINUM FIN INDOOR COIL HIGH VOLTAGE TERMINAL BLOCK LOW VOLTAGE TERMINAL BLOCK LONG LASTING POWDER PAINT FINISH EARTH TONE COLOR HIGH EFFICIENCY COMPRESSOR RIGIDLY MOUNTED HIGHLY EFFICIENT ENHANCED COPPER TUBE /ALUMINUM FIN OUTDOOR COIL DECORATIVE PROTECTIVE COIL GUARD 3 -SPEED DIRECT DRIVE BLOWER MOTOR WITH SLIDE -OUT BLOWER ASSEMBLY HEAVY GAUGE REMOVABLE BASE RAILS RATINGS MODEL BHA COOLING CAPACITY 80 / 67 -95 °F HSPF1 SOUND RATING2 (dbels) NET HEATING CAPACITY AVAILABLE ELECTRIC HEAT NOMINAL CAPACITY KW @ 47 °F @ 17 °F MBH SEER MBH COP MBH COP SINGLE PHASE THREE PHASE 018 18.5 10.2 6.6 77 _ 18.5 3.0 9.3 2.0 5.0, 7.5 N / A 024 23.8 11.0 7.0 75 23.8 3.0 12.1 2.0 5.0. 7.5. 10.0 N / A 030 , 29.8 10.2 7.0 79 29.0 3.0 14.7 2.0 5.0, 7.5, 10.0, 15.0 N / A l R 036 36.0 41.0 10.6 10.2 7.0 7.0 83 83 36.0 41.5 3.0 3.0 19.2 20.8 2.0 2.0 5.0, 7.5, 10.0, 15.0 5.0, 7.5, 10.0, 15.0 10.0, 15.0 10.0, 15.0 042 048 48.0 10.0 7.0 79 47.0 3.0 22.0 2.0 10.0, 15.0, 20.0, 25.0 10.0, 15.0, 20.0, 25.0 060 57.5 10.0 _ 7.0 79 58.5 3.0 35.0 2.0 _ 10.0, 15.0, 20.0, 25.0 10.0, 15.0. 20.0, 25.0 SEER = Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in watt -hours during the same period. COP = Coefficient of Performance - the total heating capacity provided by the refrigeration system, including circulating fan heat but excluding supplementary resistance (BTU's per hour) divided by the total electric input (watts) x 3.412. HSPF = Heating Seasonal Performance Factor - the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. (Based on Region IV minimum design heating requirement). Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.2 Rated in accordance with ARI Standard 270. PHYSICAL DATA MODELS BHA 018 024 030 036 042 048 060 INDOOR CENTRIFUGAL BLOWER (Dia. x Wd. in.) 9 X 6 10 X 8 10 X 8 10 x 8 11 X 10 11 X 10 11 X 10 BLOWER FAN MOTOR HP (Three Speed) Y Y2 Y2 Y4 % 34 1 ROWS DEEP 2 2 3 3 3 3 3 INDOOR COIL FINS PER INCH 15 13 13 15 15 16 16 FACE AREA (Sq. Ft.) 4.38 4.38 4.38 4.38 4.38 5.62 5.62 PROPELLER DIA. (in.) 22 22 22 22 22 22 22 OUTDOOR FAN FAN MOTOR HP 14 t4 14 l4 �< to t4 NOM. CFM TOTAL 1,800 1.800 1,800 2,400 2,400 2,800 2,800 ROWS DEEP 1 1 1 1 1 1 1 OUTDOOR COIL FINS PER INCH 20 20 20 20 20 16 20 FACE AREA (Sq. Ft.) 8.3 11.7 _11.7 11.7 11.7 16.4 16.4 CHARGE REFRIGERANT 22 (Ibs. /oz.) 4 / 12 5 / 12 7/ 8 5 / 5 5 / 5 9 / 0 10 /0 FILTER FACE AREA (Sq. Ft. / Qty. / Size) 4.28 / 2 / 14" x 22" COMPRESSOR HERMETIC Type, (Qty. = 1) I Recip Recip Recip Recip Recip Scroll Scroll 4 Unitary Products Group UNIT DIMENSIONS HIGH VOLTAGE CONN. %" DIA. KNOCKOUT FRONT v-u-z. HIGH VOLTAGE CONN. 13%2" DIA. KNOCKOUT LOW VOLTAGE CONN. DIA KNOCKOUT SIDE SUPPLY AIR OPENING "A" (OVERALL) 036 - 21311 - 003 -A -0104 COMPRESSOR SERVICE ACCESS COMPARTMENT PANEL UNIT SIZE DIMENSION "A" 018 - 042 048 - 060 SIDE RETURN AIR OPENING LOW VOLTAGE CONN. /" DIA. KNOCKOUT 28); 49yo (OVERALL) 3% FRONT 4y2 HIGH VOLTAGE CONN. 13%2" x X' DIA. KNOCKOUT 47y, (OVERALL) UNIT CONDENSATE CONNECTION 3a" NPTI (TRAP REQUIRED) 33)z 4th REFRIGERANT CONNECTIONS ELECTRICAUFILTER SERVICE ACCESS COMPARTMENT PANEL HIGH VOLTAGE CONN. 123'x' DIA. KNOCKOUT All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. 43) 40y CONDENSATE DRAIN 3," NPTI 22y, 14y SIDE SUPPLY AIR OPENING 28% OUTDOOR COIL BOTTOM SUPPLY AIR OPENING 3% BACK 14 y2 15 28% 3 SIDE RETURN AIR OPENING 2 3y, BOTTOM RETURN AIR OPENING 20 Unitary Products Group 036 - 21311 - 003 -A -0104 CENTER OF GRAVITY FRONT OF UNIT CENTER OF GRAVITY 25 , Z?/ 47y, 49y CLEARANCES UNIT CLEARANCES Innlmmuml Front 12" Back 0" Left Side (Filter Access) 24" Right Side 24" Below Unit/ 0" Above Unite 36" (For Condenser Air Discharge) Units may be installed on combustible floors made from wood or class A, 8 or C roof covering material. 2 Units must be installed outdoors. Overhanging structures or shrubs should not obstruct outdoor air discharge outlet. NOTE: FOR UNITS APPLIED WITH A ROOF CURB, THE MINIMUM CLEARANCE MAY BE REDUCED FROM 1 INCH TO 1/2 INCH BETWEEN COMBUSTIBLE ROOF CURB MATERIAL AND THE SUPPLY DUCT. Ct) BHA UNIT SIZE SHIPPING WEIGHT OPERATING WEIGHT CORNER WEIGHTS A B C D 018 350 345 103 92 73 82 024 350 345 95 92 80 83 030 360 355 98 94 82 85 036 367 362 100 96 84 87 042 394 389 107 103 90 93 048 445 440 121 117 102 105 060 490 485 133 129 112 116 MINIMUM CLEARANCE OF 1' ALL SIDES FOR THE FIRST 3' OF DUCT FOR 20825 kW. ZERO INCHES THEREAFTER, FOR ALL OTHER HEATERS, ZERO INCH CLEARANCE ALL SIDES FOR ENTIRE LENGTH OF DUCT. FLEXIBLE DUCT COLLAR Unitary Products Group 21 JOB NAME LOCATION PURCHASER ORDER NO. ENGINEER SUBMITTED TO FOR: Reference Approval Construction SUBMITTED BY DATE ".7 UNIT DESIGNATION: Schedule No. 42% 40% 17% MODEL NO. 1714 � 43,v4 22 -- • rirr OPENING FOR SUPPLY AIR DUCT A, 1> FRONT MODEL 1RC0449 1 RC0463 DIMENSION "A" 8 14 INSULATED PANELS NOTE: 1. Roof curb is built to NRCA standards. 2. Roof curb is constructed of 18 gauge G90 steel. 3. Unit duct supports are provided. 4. Full perimeter 1 x 4 wood nailer. 5. Curbs are shipped unassembled. 6. Corner hinge pins are used for assembly. WOOD NAILER r RECOMMENDED DUCT SIZE SUPPLY AIR DUCT 17Ye" x 211'Z" RETURN AIR DUCT 17 fa" x 16a' Roof opening; 43;8" long x 18 N" wide Subject to change without notice. Printed in the U. S. A. ROOF CURB MODELS: 1RC0449 AND 1RC0463 FOR THE FOLLOWING UNITS; BHA, BHH, DEB, DEH, DNA, DNH, DNP, BHP 036 - 22442 - 001 -A -0203 Supersedes: 530.46 -SD1OY (197) 111YORK® Heating and Air Conditioning Field Installed Accessories - Non- cntctrrcar SUB I MODEL V VOLTAGE D DESCRIPTION W WHERE USED W WEIGHT I V VOLUME F FAM S tAK0107 A All R Round Adapter Kale round (Side Duct 2 2 0 05 0 01 Al{ Units 2 22 2 2 2 20 9 90 1800406 A All B Burglar Bars (works with Interposing A 10 O 2 2 20 9 90 1FA0406 A All 1 OA Damper 0%thru50% i 1FE0413 A All F Ftue Extension Kt A All GaslElectric Models 0 0 0 0.3 2 20 9 90 1FF0110 2 208230.1.60 D D'N/H( Z / 0 / X) 024-030 2 2 2 0 05 0 01 Filter Frame Krt (Single phase models D D•NX 036 2.5 3 3 0 05 0 01 1FF0112 2 208/230-1-60 F D'E( Z /0) 024 -060 2 2 2 0 05 0 01 1FF0114 2 208230 -1 -00 V 1HA0802 A All H HlghAttlude Instruction Packet A All Gas/Electric Models . . 0 0 0.9 2 20 9 90 1H00812 A Alt D Hat Guard Kit D'NX024 1 10 5 5 5 5 0 01 D'N(Z /0) 024 -036 1 10 5 5 0 05 0 01 11400819 A All ( B'H(Z / Q) 024 -036 10 5 5 0 05 0 01 11400814 A All 0 D'N(Z / O) 042 -060 (MicroChannel 1 15 7 7 0 05 0 01 1H00820 A All U D'EZ024.042 1 15 0 05 0 01 11400821 A All ( 0'FZ048 -060 1 15 7 7 0 05 0 01 1H00822 A All 0 D'NX038,048 1 10 5 5 0 05 . .01 1HG0817 A All D B'H( Z10) 042-060 10 5 5 0 05 0 01 11400818 A All . 1LN0802 A All L Low NOx Kt A All Gas/Electric Models 2 2 1 1 2 20 9 90 1NP0807' A All N Natural Gas to Propane Conversion Kit 2 O'N/H(Z /0)024 -036 2 0 0.9 2 20 9 90 2 0 0.9 2 20 9 90 1NP0809' N N1 ( Natural Gas to Propane Conversion Kit 0 0•NX 024 2 1NP0808' A All N Natural Gas to Propane Conversion Kit 2 D'NH(Z /0)042 -060 2 0 0.9 2 20 9 90 2 0 0.9 2 20 9 90 1NP0810' A All ( Natural Gas to Propane Conversion Kit D D'NX 036-048 2 1RC0449 A All ' ' Roof ur. A All Units r r 3 3 2 20 9 90 1RC0463 A Ail 4 4' Root Curb A All Units n num 3 3 2 20 9 90 1 WC0410 A Alt W Wooden Crate or extra protection during A All Units 2 258 5 58 2 20 9 90 Please refer to propane conversion kit instructions for proper natural gas to propane ma ps. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary MECH -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Info Project Address Date /�j)6.po n, pr /� 1 ON v��(MI et Ave S For Building Dept. Use -1 kwaL(4 4 9PIEA Applicant Name: 4tyizi,E seimzoz ApplicantAddress:374Z- Q ST NG , AuILURN) `NA Applicant Phone: 42s'2s'I_ 4840 Project Briefly describe system type Description mechanical and features. Plans FEP(.Ac.t (0 tx2.6'TTNb Z-104 Nkftivoto Ve vvtrt4 Nev 3=1K "r w EGo1*I6M��ER, 2E PLFM, ,1/ k yam' b. 3-104 -Sear `1 r Wr 1 f7- UGaSr Ist 0 Ant P hbeu 1W. Include documentation requiring compliance with commissioning requirements, Section 1416. • Indudes Compliance Option e Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name Model No.1 Capacity2 Btulh OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N RIO NiP -113Rt€ R SOCe 43lo 3;690 tc16N.q az Heating Equipment Schedule Equip. ID Equip Type Brand Name Model No.1 Capacity2 Btulh OSA cfm or Econo? Input Btuh Output Btuh Efficiency's Heat Recovery Y/N KA t+? CAR "UF.R SO€ 433 3s,u426 Cumtt. - Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP1 HP/BHP Flow Controls Location of Service lif available. 2 As tested according to Table 14 -1A through 14- G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types:. variable airvolume(VAV), constant volume (CV), or variable speed NS). 6 Exception numberfrom 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary (back) MECH -SUM 2009 Washington State Energy Code Comp iance Forms for Nonresidential and Multifamily Residential Revised February 2011 System Description See Section 1421 for full description of Simple System qualifications. All Systems: • No humidification? • No Reheat? If Heating /Cooling or On 9 Only: [Constant vol? • S lit system? <= 84,000 Btuh? economizer Included? ErAir cooled? Packaged sys? • Btuh? • Cooling Cap < =15 Btuh/112? • Heating Ca p• > 0 & < =10 Btuh/112 If Heating Only: • <1000 cfrn? • <30% outside air? • Heating Cap. < =10 Btuh/ft2? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Yes Heating/Cooling or Cooling Only Reference Section 1421 • lifies Economizer Exception ion 1 Simple System Allowed (section 1420) • Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical - Complex Systems Checklist MECH -COMP 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Address I35 CLf 1.itPnC AVe SS Date The following additional information is necessary to check a mechanical permit application for a complex mecj,anical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH -CHK checklist for additional requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable altemative. For Building Department Use . Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes ADDJTIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY IV `J 1431.1 Field assem. sys. Provide calculations for total onsite energy input/output to equip. 14 4 1431.2 System Sizing Indicate equipment & system sizing complies with 1431.2 N14 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1` 1432.2.1 Air system reset Indicate automatic temperature reset & operation sequence U 1432.2.2 Hydr. Sys. reset Indicate automatic temperature reset & operation sequence v 1432.3.1 Hydr. Var. Flow Indicate variable flow method for all applicable systems q 1432.3.X Hydronic Isolation Indicate method of isolation for all applicable systems U 1432.4 DDC Capabilities Indicate control capabilities including demand response setpoind adj. ‘.• 1432.4 DDC data mgmt Indicate metering and trending capabilities. w 1432.5 Pressure Reset Indicate static pressure reset for VAV systems Y� 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption. Demonstrate higher efficiency equipment if required. 1 IVr /i4 1433 Water Economizer Indicate water economizer and provide calculations showing compliance with 1413 if 1433 Exception 3 is utilized V 1434 Separate air sys. Indicate special requirement zones and indicate systems ti 1435 Simul. Mg. & clg. Indicate method of prohibiting simultaneous heating and cooling, or state excpetion and show supporting calculations v. 1436 Heat recovery Indicate heat recovery of all applicable systems on plans; complete and attach heat recovery calculations {,,, 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency V 1438 Variable speed drives Indicate VS control or equivalent on schedules for all applicable equip. t" 1438.1 Heat Rejection Indicate heat rejection equipment types and fan types 1. 1438.2 Hot Gas Bypass Indicate cooling equipment staging and capacity modulation abilities r. 1438.3 Large Volume sys Indicate multiple system rooms & indicate ventilation control v% 1439.1 Kitchen Hoods Indicate source and conditioning of make -up air "', . 1439.2 Laboratory Exhaust Indicate HR, VAV, semi - conditioned makeup, or CERM calc If "no" is circled for any question, provide explanation: Decision Flowchart Start Here Use flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for complete information on the requirements. Section 1411.1 Equipment Efficiency Shall Meet Tables 14 -1A through 14-1G s/Oil Fume input > 225,000 uh or Any U • eate ace >50 with Design > 25 people per 000S Air System Serving Multiple Zones? Yes 1411.1 IID & Power Venting or Damper. If input > 225,000 Btuh then 1412.6 Modulating Controls Required Yes Section 1411.1 0.75% Maximum Jacket Loss Yes ♦ Section 1412.8 Ventilation Controls for High -Occupancy Areas Yes Section 1431.1 Calculations of Total On-Site Energy Input & Ouput Required Section 1432.2.1 Supply Air Reset Controls Required (continued on back) 7. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical - Complex Systems (back) 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential MECH -COMP Revised February 2011 Hydronio System Yes 0. Section 1432.3.2 through 1432.3.5 Device Isolation Required Section 1432.3.1 Variable Flow Design Required dronic Syst Heated or Cooled 300,000 Btu Section 1432.2.2 Water Temperature Reset Required 0 Mechanical Cooling? Section 1433 Economizer Required C Present Total Cooling > 780kBtuh Section 1432.4 DDC Required Wdh Trending and Demand Response 0 Supply OSA > =5000 CFM Yes* Section 1436.1 50% Effective Heat Recovery Required Steam System Yes♦ Section 1436.2 Condensate Recovery Required N No 4 Hour Ops, ter Cooled Conden tuh, & Servi kBt >1,50 Yes p,„ ter Section 1436.3 Condenser Heat Recovery Required emot Refrigeration Condensers > 500kBt Yes* Section 1436.4 Refrigeration Condenser Heat Recovery Required No No ystem or Zones w/ Simultaneous tg. & Clg.? Yes• Section 1435 Zone Controls Must Reduce Supply Air Quantity Before Reheating/Recooling ystem o ystems serving a room have 10,000 C ppI Yes—• Section 1438.3 Controls Must Reduce Airflow When System In Not Heating or Cooling 0 No Section 1438 Variable Flow Devices Required otor Incl. in Eqpmt. Coved by Tbl 14-1 A -14- 1G? Section 1437 Motors Must Meet Efficiencies in Table 14-4 No DONE Section 1439.1 No Heating or Cooling for at Least 50% of Make -up Air Yes Section 1439.2 One Required: a. Heat Recovery per 1439.2 b. 50% VAV Exhaust & Make -up c. 75% Direct Makeup w/ Tempering Only d. Combined Energy Reduction Qer> =Amin Yes 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Economizer MECH -ECO 2009 Washington State Energy Code Compliance Fo s for Nonresidential and Multifamily Residential Revised February 2011 Economizer Summary Check box(es) for exceptions being claimed. List the system /equipment that qualifies for each exception. See Section 1433 for full description of Economizer requirements. Full Air Econo: Ex 1: ❑ Ex 5: Ex 9a: E Ex 2: ❑ Ex 6: Ex 9b: Ex 3: ❑ Ex 7: ❑ Ex 9c: Ex 4: Ex 8: Ex 10: Decision Flowchart Use this flowchart to determine if project complies with Economizer requirements. If not, the Systems Analysis Option must be used. Yes Reference Section 1433 \ J Group R Occ. ified Un m Table 14 -1A, =, / EER 15% ode ception 8: Unit Cap <20,000 Btuh Yes Full Air Economizer - Complies Yes ception it Cap <54,000 B it not Exterior 'ace No ception . it Cap < 33,000 Bt nit not Exterior o djacen Idg. • Cap. w/o economizer <72,000 Btuh or 5 %? Exception 2: Chilled Water Sys. • er 25% over Idg Cap wo Econ — 80,000 Btu or 2 ptio er Cooled Re . aterside Economize ing chiiled b Sys 0 NIo xception 3 Syste Cap. <- 500 tons No Exception 4: Cooling 75% Site HR or Solar Exception 5: Special OA iltration Need ception Dehumidification with supporting rgy anal xception 7: Heat Pump Loop eting All Crite No No ception 9: Dedicated Server or Eq Rm e erved b 14 -1A or 14 -1B uipme . 9a: EER & IPLV Ye Over ••e No No ception 10: RF System Meeting All Criteria c. RAE 127 is 14- 1A/14- IP c. 9•. Water Econo ER & IPL 5% . - 'ode Ye P• Lo ote C or be cap >85,00 Yea No No Does Not Comply Qualifies for Full Air Economizer Exception - Complies 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist MECH -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Address I SI 3C'y1 OLMP$e Ale S, 'Date The following information is necessary to check a mechanical permit application for compliance with the mechanical, requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department _ Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment Performance Yt5 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M i K / /1 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper & jacket loss l 1411.1 Air - cooled chiller Provide total air and water chiller capacity t' 1411.2.1 Water - cooled chiller Full -load and NPLV values adjusted for any non - standard conditions 11C) 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule IA l 11114 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls 14(4 1412.1 Temperature zones Indicate locations on plans Y1412.2 Deadband control Indicate 5 degree deadband minimum M 1 itf74. 1412.3 Humidity control Indicate humidistat Y 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback l'1. 14,4 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage 4 1412.4.2 Optimum Start Indicate optimum start controls AS 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule M 1 14/7 1412.6 Combustion heating Indicate modulating or staged control M 1412.7 Balancing Indicate balancing features on plans at 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas 4 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. V 1422 Thermostat interlock Indicate thermostat interlock on plans w 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers 64 1412.1 Single zone systems Indicate multiple cooling stage control capability. tik 1 1.- 1413.1 Air Econo Operation Indicate 100% capability on schedule K' UlA 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb •• 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. Y(+,` 1413.3 Integrated operation Indicate capability for partial cooling IA ` u A. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems Yt% 1414.1 Duct sealing Indicate duct design pressures, sealing, and testing requirements M I (■ IA 1414.1.2 Low press. duct test Indicate applicable low pressure duct systems shall be leak tested N/ 1414.1.3 High press. duct test Indicate high pressure duct systems shall be leak tested, and identify the location of this ductwork on plans Yk,S 1414.2 Duct insulation Indicate R -value of insulation on duct M l_ 1415 Piping Systems ' 14 f / 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements • 14 f /. 1418.3.2 System Balancing Indicate air and water system balancing requirements YU 1416.3.3 Functional Testing Provide sequence of operations and test procedures. its 1416.3.4 Documentation Indicate O &M manuals, record drawings, staff training till 1416.3.5 Comm. Report Indicate requirements for final commissioning report 1416.4 Compliance Chklist Submit to building official upon substantial completion. l`1 ' Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer FILE COPY Permit N©., STRUCTURAL CALCULATIONS AND NOTES FOR SOUTHCENTER SOUTH 18350 OLYMPIC AVENUE SOUTH TUKWILA, WASHINGTON PREPARED FOR: COMFORT MECHANICAL MAY 30, 2012 CASCADE CREST CONSULTING ENGINEERS. INC. 21902 96TH AVENUE SE SNOHOMISH, WASHINGTON 98296 (206) 909.7808 PREPARED BY: KEITH MOORE, S.E. - Sy, �,., 0 WA mr o \ R 8959 �p / FG /STEFi�/ ZONAL ENS'\ o I EXPIRES REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 0'7 2012 • City of Tukwila BUILDING DIVISION cmr JUN 012012 PERMIT CENTER M 24M GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS AND THE INTERNATIONAL BUILDING CODE (IBC), 2009 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNIT RTU 1- 463 POUNDS RTU 2 - 437 POUNDS EARTHQUAKE SDS = 0.878 SITE CLASS C to D WIND 85 MPH, EXPOSURE B 3. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE SKETCHES ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 4. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 6. FRAMING LUMBER SHALL BE KILN DRIED OR MC -19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS: (2x MEMBERS) (3x & 4x MEMBERS) HEM -FIR NO. 2 HEM -FIR NO. 1 Fb = 850 PSI, Fv = 150 PSI Fb = 850 PSI, Fv = 150 PSI 7. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG - TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C -2011. 8. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD - FORMED STEEL STRUCTURAL MEMBERS ". 9. WOOD SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18.6.1. 10. METAL STRAPS, IF UTILIZED, FOR ANCHORAGE OF MECHANICAL UNITS SHALL CONFORM TO ASTM A446 GRADE A WITH A MINIMUM YIELD STRESS OF 33 KIPS PER SQUARE INCH. 1-4 a 11. CONNECT THE NEW UNITS TO THE METAL CURB WITH (2) #10 SHEET METAL SCREWS ON EACH SIDE OF THE UNIT. PLACE EACH SCREW 6" TO 8" FROM EACH CORNER OF THE UNIT. 12. CONNECT THE METAL CURBS FOR EACH UNIT TO THE WOOD ROOF STRUCTURE WITH (2) #10 x 2" LONG ON EACH SIDE OF THE UNIT. PLACE EACH SCREW 6" TO 8" FROM EACH CORNER OF THE UNIT. M9' - 161 Tro c� CLU • 4-FN4A c(LS of f"FR -1 n.i_T! of ∎ i) -2 zx w 1)5 2(0 - IGelLS ZWt 4 v4-: c - 2az-'b +.ic ;EIS N LiarS 1 I ti 12 FofL csvtilnl Ec rro4 jy� L lq rt-�� To f F- I .�T _ 206.-.ri I G _ P F7V- f ASCAfl CREST CONSULTING ENGINEERS. INC. PROJECT: ,�oJ'itc �EP"cL. Teo (..te ENGR: DATE: 51-50 SCALE: `Z SHEET j.O.,( -6C:1� P:71/ iP � -Ci �i V �x`}4,i rn #t C-, �� ? j P_ j7 r`c tt {mil �c-f�c O CT3 u.1 - • Cx-a .ks �. T 47 , 416 CASCADE Mister COMSULnnie EMGDOZERS. MC. PROJECT: �7o `I-14- rta- ENGR: JC DATE: 44(7, SCALE: "1 SHEET 4112 ncn QS tin •vcr) /Ani kti2lot • 42(INiatsim(1, 03Sn v_Mas (I) wmpaazi W8() VP\ (VIltsN'Ic\L • .0t0313 (1% kn-11 AA2N cs 3AV -Acily4 lop C1S%1 • 4.kup\ "T- ox. 3-)vick41 tuocs ummsnis pacr) • • or— . i' , . --_ — . , Z • t"r‘t% 49 Af3 14"L'INS'oc) MI IS1 4 i R ,201$6. tan„s -z, twathm Ilci . ,Eynki :711rNA • II . \ Tc 1F-' • , AO _. j z.-)inq tlfl 0 1 • . • rro,7)-0 milaoa 1,11 17 1 v L.3 vitt6vc kg' jit71; ‘0140) • .._..... NI elo .7-' • as ipq QS tin •vcr) /Ani kti2lot • 42(INiatsim(1, 03Sn v_Mas (I) wmpaazi W8() VP\ (VIltsN'Ic\L • .0t0313 (1% kn-11 AA2N cs 3AV -Acily4 lop C1S%1 • 4.kup\ "T- ox. 3-)vick41 tuocs ummsnis pacr) • • Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.438 Longitude = - 122.25100000000002 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 1.386 (Ss, Site Class B) 1.0 0.473 (S1, Site Class B) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.438 Longitude = - 122.25100000000002 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and'SM1 =FvxS1 Site Class D - Fa = 1.0 ,Fv = 1.527 Period Sa (sec) (g) 0.2 1.386 (SMs, Site Class D) 1.0 0.723 (SM1, Site Class D) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.438 Longitude = - 122.25100000000002 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2/3 x SM1 Site Class D - Fa = 1.0 ,Fv = 1.527 Period Sa (sec) (g) 0.2 0.924 (SDs, Site Class D) 1.0 0.482 (SD1, Site Class D) 2005 ASCE 7 Standard Latitude = 47.438 Longitude = - 122.25100000000002 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 = Fv x S1 Site Class E - Fa = 0.9 ,Fv = 2.4 Period Sa (sec) (g) 0.2 1.248 (SMs, Site Class E) 1.0 1.136 (SM1, Site Class E) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.438 Longitude = - 122.25100000000002 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2/3xSM1 Site Class E - Fa = 0.9 ,Fv = 2.4 Period Sa (sec) (g) 0.2 0.832 (SDs, Site Class E) 1.0 0.758 (SD1, Site Class E) CONTROL Box ACCESS PANEL BLOWER ACCESS PANEL f• INDOOR BLOWER &ELECTRIC C HEAT 10T . ACCESS PANEL CON1ROLBOX ACCESS PANEL GRILLE OUTDOOR COIL UOUID PRESSURE SERVICE PORT SUCTION PRESSURE SERVICE PORT CONDENSATE DRAIN OW NPTF) E 2 3/4" ELECTRIC HEAT WIRE ENTRANCE (ACCESSORY) MODEL NUMBERS A B C D E F G PCO24. 030. & 036 56 1/4" 24" 26 7/8" 25" 19 1/2" 19 13/16" 3 1/4" PC042, 048, & 060 63" 32" 34 3/8' 32 1/2° 21 7/8" 27 5/16" 1 7/8" OUTDOOR COIL MO)ELNUMBERS A B C D E F G H PC 24,030, &036 9-5/8" 15" 1 -3/4" 1 -7/16" 8-1/4" 9-1/4" 12" 14" PC 2,048, & 060 10- 11/16" 19" 2-1/4" 11/16' 9-118" 10 -1/8" 14" 14" CIRCULAR DUCT MOUNTING PANEL (SUPPLIED WITH UNIT) RETURN DUCT OPENING SUPPLY DUCT OPENING MODELNUMBERS A BC D E F PCO24, 030, & 036 3-518" 12" 3" 17 12" 16" PC042, 048, & 060 3-3/4" 14" 5" 14" 14" 16" CONTROL BOX ACCESS PANEL BLOWER ACCESS PANEL i UNIT WITH CIRCULAR DUCT PANEL REMOVED OUTDOOR COIL NOTE ANGLE IS ON UNIT FOR OPTION OF HAVING SAME SIZE SUPPLY & RETURN DUCTWORK TO UNIT RETURN DUCTOPEN/NO SUPPLY DUCT OPENING PC - DATA AND SPECIFICATIONS (1) Certified perARI 210 (2) BTU/Watt Q 80/67 F inside - 95 °F outside air (3) M.O.P. (Maximum Overcurrent Protection) Note - May use fuses or HACR type Circuit Breakers of the same size as noted BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. Vim- - 26S Qi3 ! 06 4?F?c. 425*• PCO24-1 PC030 -1 PC036 -1A PC036 -3A PC042 -1A PC042 -3A Total Cooling- 23200 28000 36000 36000 42000 40000 BTUH Sens. Cooling- 16800 20900 26200 26200 30400 30400 BTUH SEER (1) 10 10 10 10 10 10 EERa (2) 9 9 9 9 9 9 Sound 8 8 8 8 8.4 8.4 Rating(bels) Indoor Blower Type DD DD DD DD DD DD Size -DxW 9x6 9x6 10x6 10x6 9x8 9x8 Motor H.P. 5-Jan 3-Jan 3-Jan 3-Jan 3-Jan 3-Jan Evaporator Coil Face Area (ft2) 3.33 3.33 3.33 3.33 3.33 3.33 Fin/In. 14 14 14 14 14 14 No. of Rows 2 2 3 3 2 2 Outdoor Fan Fan Dia. (In.) 18 18 18 18 22 22 Motor H.P. 6-Jan 6-Jan 6-Jan 6-Jan 4-Jan 4 -Jan Condenser Coil Face Area (ft2) 12.1 12.1 12.1 12.1 16.2 16.2 Fin /in. 16 16 16 16 19 19 No. of Rows 1 1 1 1 1 1 Electrical Ph 1 1 1 3 1 1 Volts 208/230 208/230 208/230 208/230 208/230 208/230 Compr. RLA 12.1 14.7 17.3 17.3 19.2 12 Compr. LRA 57 78 89 89 120 60 Indoor Biw FLA 1.3 2.3 2.6 2.6 2.3 2.3 Outdoor Blw 1 1 1.6 1.6 1.6 1.6 FLA Min. Circuit 17.5 21.7 25.3 17.7 27.9 18.9 Amp. M.O.P. (3) 30 35 40 30 45 30 Net Weight 240 245 265 F 265 335 325 Shipping 255 260 280 280 350 350 Weight (1) Certified perARI 210 (2) BTU/Watt Q 80/67 F inside - 95 °F outside air (3) M.O.P. (Maximum Overcurrent Protection) Note - May use fuses or HACR type Circuit Breakers of the same size as noted BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. Vim- - 26S Qi3 ! 06 4?F?c. 425*• Chi) Project 18350 Sctr South Prepared By: Unit Report For 3T Pkg HP -SmII Pk 05/25/2012 10.15AM Unit Parameters Unit Model. - _._50EZ- A36- -3 Unit Size _..__ _....... ...._.......___...___.._.._.36 (3 Tons) Volts- Phase -Hertz __...._ .208 -1-60 Heating Type:. __.__ ..__...._._....__..�_�___..Heat Pump Duct Cfg:.__._.. __Vertical Supply/Vertical Return Warranty Information 1 year warranty on parts 5 year warranty on compressor Dimensions (ft in.) & Weight (Ib.) "' Unit Length. 4' 0.1875" Unit Width:..._..._........._..._. ......- •--- .._....._.___..2' 8.625" Unit Height...__ 3' 7.9375" "" Weights and Dimensions are approximate. Weight does not include roof curbs, unit pact®ging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Total Operating Weight_._.__.__ __.__..._.__...343 lb ADD for Economizer Weight = 65 Ibs ADD for Curb = 55 ibs No optional warranties were selected. NOTE: - Please see Warranty Catalog 500- 089.for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50EZ -A36 -3 Rooftop Unit 1 Accessories CPHEATER052A00 3.8/5.0 kW, 208230 -1-60 volt, Electric Heater 1 CPCRKHTROO8A00 240V Crankcase Heater 1 CPECOMZR007A00 Economizer 1 CPRFCURB011A00 14 inch Common Flat Roof Curb 1 CPRLYKJTOO1A00 Economizer relay kit for heat pumps 1 Packaged Rooftop Builder 1.29v Page 2 of 6 Project 18350 Sctr South Prepared By: Certified Drawing for 3T Pkg HPSmII Pk 05/25/2012 10:15AM 37 1113 1710.51 -+ 9.15716 +- 21 1/11 0.13116 •.-- 1252.41 32.!/3 / :0718 011111- - 6z ..1 e1/- 3)8,1,1. 6 2.6 t (.6303 0100(0 LEFT SIDE VIEW 12.1) '/ 1325.4: 3-530 142.11 47 7113.61 C01r700001- P 1E. r i 00 '6 3716 11231.0: FRONT VIEW - 6.0111 P1171 - 115841541 4( ::31 74551 7.3/6 70519 (1571 r 01.9711) (iY1j(100'CS • 1 f1 uI 177. x, [14 -1 1010[ r u c.31, « P1a- m n » a 11 ' 10ii 3eu : actt a n '0:34 3( 361" (LLC191C11 :4114C7ll:31C3 311" 17. 15 1 10 /'917 00(007 :6,05 55(1.421•••3( 203103).'•3 325 ,119.6 4 124(3 12)0 C217_1 57 '4011. 11,04 •1.314 531.0 •4 -11 1 004.' 11 53(2. 133--- 13 1S:C 253 /231.1, 200/210.340 110 .150.1 41•(1 1072 '14)13, 531,1 •4.311 374,+ 5000 436 13 10 3081133.1. (081130.3-90 131 152.3 42.146: IC(C •1.3111 511,7 '4 -3,4 174.1 511(.436•• -60 413.3.60 350 '153.1 42.1/6 • 107c :4•3/11 511.1 :4.371 374.1 14 4(6.4 111.1 151.1 154.1 101[1 000 1*3- FtC[ /1 I(01111I0 Al 144'070 1101470ED 11111111111111111 IIIIIIIIIIIIIII 12•'3/14 (125.61 1•'74 (34.21 tea 0'.)) •�� /t)/N (•00 21 01718. 1117.0 E:32.2: . C011 RIGHT SIDE VIEW :4,3114 3 MOWED [1EAP41G3 TO COMMIT/2 PAUL 16(010 (1701 'Or 0; 0617 14 1333.61 ' 3007 310E 02 2123 2 150.01 1 SIDE CP?03-1( D0C13 14 1333.61 001101 OF 0617 6 10.0: (1(5871(15 P6105 11 311.11 5EC. I E9Q351 GF/R16/J3 IsC.(3 7980 3(73(51 03116, 00511 5311. 616E tt :1011.01 Jut- 336 3!07731616 002(4(10, P0000 3505' 613E 31 1911.0) 7511 400 310C1 03 50053(01 DAUS 405 011151 010(1510,53604550, PO1E1 13711 010' 42 (1066.01 REDO= CLEW= 101 66410/ AND 033VC0110 (65913 1x1 190. C011 4(5136 113E 11 2314.31 71151 5006• E100.. 43 01461.01 114(111 707 41C IE003(06111 UNIT 700 10 (1211.21 010E 02205:TE 35577 11 011.01 005' 14310 12 (134.01' ,4501500 DISTI9CE3:l 31(7 I1 71450 . 3 I1 1 '2 115157 1006 0453 ('3126.15[41'J•E3 E 709440(1'6131 (6000'(33. 3:6145:063 IP 11 4d1 I9 ID 11401.201.2 1 • 1111111111111111111 1 _ :81,1 1 501126 01 :00 d /26 ;40.7003 5052. 606• -35 {206/23111.5 21.0 51.2'23.2 16.1 34.1.121.155 1 5611. 30 :2 433--- 13lS14 416 73 /514 120613114.3 :3.2 1206/214117.2130.3 51.214.7 51.7124.4 71.7 60.1 31.21112.1 00.3 31.6134.0 67.0 50(2- 131 - -.3 1 110 ,11.2:31.3 51. 7124.4 60.6 65.11111.313.2 101[1 000 1*3- FtC[ /1 I(01111I0 Al 144'070 1101470ED 11111111111111111 IIIIIIIIIIIIIII 12•'3/14 (125.61 1•'74 (34.21 tea 0'.)) •�� /t)/N (•00 21 01718. 1117.0 E:32.2: . C011 RIGHT SIDE VIEW :4,3114 3 MOWED [1EAP41G3 TO COMMIT/2 PAUL 16(010 (1701 'Or 0; 0617 14 1333.61 ' 3007 310E 02 2123 2 150.01 1 SIDE CP?03-1( D0C13 14 1333.61 001101 OF 0617 6 10.0: (1(5871(15 P6105 11 311.11 5EC. I E9Q351 GF/R16/J3 IsC.(3 7980 3(73(51 03116, 00511 5311. 616E tt :1011.01 Jut- 336 3!07731616 002(4(10, P0000 3505' 613E 31 1911.0) 7511 400 310C1 03 50053(01 DAUS 405 011151 010(1510,53604550, PO1E1 13711 010' 42 (1066.01 REDO= CLEW= 101 66410/ AND 033VC0110 (65913 1x1 190. C011 4(5136 113E 11 2314.31 71151 5006• E100.. 43 01461.01 114(111 707 41C IE003(06111 UNIT 700 10 (1211.21 010E 02205:TE 35577 11 011.01 005' 14310 12 (134.01' ,4501500 DISTI9CE3:l 31(7 I1 71450 . 3 I1 1 '2 115157 1006 0453 ('3126.15[41'J•E3 E 709440(1'6131 (6000'(33. 3:6145:063 IP 11 4d1 I9 ID 11401.201.2 1 • 1111111111111111111 1 _ HOlIlIlIlIlIlIlIl . I6I'P11 CP107- -3116 1(3301 0«9280 =mom 1161.11 IIC 0 0 3•3(70 162,31 -+ 3.716 •�- 21.5(0 ��+ 0 7/6 1235 3 -542.11 (250.1: REAR VIEW e.n ' 01,74/C9 1,711(11/1 SIVGLE /ONE CL:CTR(C COOL:NG A. I'CAt :90 50 :Z5CD35' U. 3.0 Packaged Rooftop Builder 1.29v Page 3 of 6 SUBMITTED TO: COMPANY: DRAWN BY T. HUBBARD JOB NAME' EQUIPMENT: NOTES: Small Curb for Carrier SPP Units with Sheet Metal Base Rails 48/60ES, EZ, VL A24-A36; 60GL, JZ A24 -A36; 48 /60VT, XL, XT A24 -A30 Units Part Number: CRB -SDSML ** Features; • Constructed of heavy gage galvanized steel. • Roofcurb ships knocked down. • Easy field assembly. • Insulated deck pan. • Gasketing package and hardware included. • , Wood nailer provided. Carrier Unit 48/50ES. EZ, VLA24 -A36• 50GL, JZ A24 -A36: -4 48/50VT, XL, XT A24 -A30 M croMeII Curb No. CRB - SDSML -11 CRB - SDSML -14 CRB - SDSML -24 Carrier Curb No. CPRCURB010A00 CPRCURB011A00 N/A D 11 14' 24 NOTE: For full insulated roofcurb, add CI to the end of the part number. NOTES: Do not use these curbs on unit without base rails. CORNER DETAIL SIDE VIEW DETAIL Tt08 DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT SE DISCLOSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT MICROMETL CORP -3035 NORTH SHADELAND AVENUE. SUITE 300 - INDIANAPOUS, IN 48228 . 1 -800802 -4822 - MICROMETL SPARKS -905 SOUTHERN WAY - SPARKS. NV 89431 - 1- 804884.4882 UNIT DIMENSIONS HIGH VOLTAGE CONN. ;S DIA. KNOCKOUT FRONT COMPRESSOR \1 SERVICE ACCESS COMPARTMENT ENNT PANEL CustA 036 - 21311 -003 -A -0104 HIGH VOLTAGE CONN. 13V DIA. KNOCKOUT LOW VOLTAGE CONN. X74" DIA. KNOCKOUT SIDE SUPPLY AIR OPENING SIDE RETURN AIR OPENING LOW VOLTAGE CONN. I/; DIA. KNOCKOUT "A' (OVERALL) UNIT SIZE DIMENSION 'A' 018 -042 048 - 060 28% 47y, (OVERALL) 49) (OVERALL) 3% FRONT HIGH VOLTAGE CONN. 1% x % DIA. KNOCKOUT - UNIT CONDENSATE CONNECTION NPTI (TRAP REQUIRED) 33)4 4th REFRIGERANT CONNECTIONS ELECTRICAUFILTER SERVICE ACCESS COMPARTMENT PANEL HIGH VOLTAGE CONN. 1%%; DIA. KNOCKOUT All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. 43% 40 CONDENSATE DRAIN NPTI 20 22y 14% SIDE SUPPLY AIR OPENING 28% 14 1 y, BACK OUTDOOR COIL BOTTOM SUPPLY. AIR OPENING 1% 14 y, 15 28 SIDE RETURN AIR OPENING 3x 3y, \ BOTTOM RETURN AIR OPENING 1% Unitary Products Group q CUsth) _1 036 - 21311 -003 -A -0104 CENTER OF GRAVITY CLEARANCES UNIT CLEARANCES (minimum) Front 12" Back 0" Left Side (Filter Access) 24" Right Side 24" Below Unit' 0" Above Unite 38" (For Condenser Air Discharge) ' Units may be installed on combustible doors made from wood or dass A, B or C roof covering material. r Units must be installed outdoors. Ovethangtng structures or shrubs should not obstruct outdoor air trge outlet NOTE: FOR UNITS APPLIED WITH AROOF CURB, THE MINIMUM CLEARANCE MAY BE REDUCED FROM 1 INCH TO 1/2 INCH BETWEEN COMBUSTIBLE ROOF CURB MATERIAL AND THE SUPPLY DUCT. BHA UNIT SIZE SHIPPING WEIGHT OPERATING WEIGHT CORNER WEIGHTS A B C D 018 350 345 103 92 73 82 024 350 345 95 92 80 83 030 360 355 98 94 82 85 036 367 362 100 96 84 87 042 394 389 107 103 90 93 048 445 440 121 117 102105 060 490 485 133 129. 112 1 116 MINIMUM CLEARANCE OF 1° ALL SIDES FOR THE FIRST 3' OF DUCT FOR 20825 kW. ZERO INCHES THEREAFTER, FOR ALL OTHER HEATERS, ZERO INCH CLEARANCE ALL SIDES FOR ENTIRE LENGTH OF DUCT. FUMBLE DUCT COLLAR Unitary Products Group 21 /tek Ws ;) V-c JOB NAME LOCATION PURCHASER ORDER NO. ENGINEER SUBMITTED TO FOR: Reference Approval Construction SUBMITTED BY DATE IUNIT DESIGNATION: Schedule No. MODEL NO. 42Y4 40% OPENING FOR — RETURN AIR DUCT ''''+L,,�- OPENING FOR �`� '<----, SUPPLY AIR DUCT \ �/j -45y 43: \ 1 FRONT MODEL 1RC0449 1RC0463 DIMENSION "A" 8 14 INSULATED PANELS NOTE: 1. Roof curb is built to NRCA standards. 2. Roof curb is constructed of 18 gauge G90 steel. 3. Unit duct supports are provided. 4. Full perimeter 1 x 4 wood nailer. 5. Curbs are shipped unassembled. 6. Corner hinge pins are used for assembly. WOOD NAILER RECOMMENDED DUCT SIZE SUPPLY AIR DUCT 17V x 21.% RETURN AIR DUCT 171;; x 16V Roof opening; 43 }B" long x 18 x," wide Subject to change without notice. Printed in the U. S. A. ROOF CURB MODELS: 1RC0449 AND 1RC0463 FOR THE FOLLOWING UNITS: BHA, BHH, DEB, DEN, DNA, DNH, DNP, BHP 036- 22442- 001 -A -0203 Supersedes: 530.46 -SD1OY (197) YORK ° Heating and Air Conditioning rum tnstauea Accessories - roon- clecmcat WHERE USED 61:11 GHT VOLUME FAM SUB MODEL VOLTAGE DESCRIPTION tAKOf07 Ag Round AdapterNt14'round(SMeDuct Croft All Milts 2 05 01 11300408 M Burglar Dais enomtze rig blade 22 2 20 00 1FA0408 All Manual OA. that 50% capability 10 2 20 80 1FE0413 All Flue Edenslon 101 141 Gas8Elecldc Modem 0 0.3 20 90 IFF01I0 208/2300.1.60 FOerRrame NI (Single phase models e D'N01( Z /Q / X) 024-030 13'14M(Z / 00 038 2 2 05 01 L IFF01I2 2082344.80 D'NX 038 MOW / Z /0) 042 D'NM(P / Z I Q) 048-080 2.5 3 05 01 IFF0114 2081230-140 LYE( 2 /0) 024.080 VEX 024-048 8'H(Z I0/ X)024-080 2 2 05 01 1HAD802 All H(gh Altitude he0ucfmn Packet MI GeslEiechtc Models 0 0.9 20 00 1100812 140 Haft Guard MI - D'NX024 10 5 5 01 11100818 141 D'14( 2 /Q) 024-038 QAaoChannel Unle Onit 10 6 -05 01 11100814 An 811(Z /Q )024-038 D'EX 024,038 8'}C(024.038 10 5 05 01 1H00820 An D'N(2/0) Utz 2-080 Channol 18 7 05 01 11130821 All 17E2024442 (fRomChannei Was Only) 15 7 05 01 11400322 A11 tYQ048-060 (PRUOehamwl thats Only) 15 7 05 01 11130817 - All 0'11X038.048 10 5 05 -01 11100818 18 E111( Z/0) 042-080 D'EX 048 S'18( 048,080 10 _ 5 05 01 1LN0802 All LawNOZ10t All Gas!EtechlcModels 2 1 20 00 114P0807' All Natural Gas to Propane Conversion Kit (Singe Stage modals only) D'N0i(Z /CS 024-038 D'NX024 0.9 20 80 1NP080' Al Natural Gas to Propane Conversion Mt (1\do Stage models only) 2 0.8 20 90 1NP0808' AG Natural Gas to Propane Conversion 101 (Singe Stage models only) D'NM(Z I Q) 042080 Dia 038.048 2 0.8 20 90 111P0810• An Netaral Gas to Propane Conversion Kd (Rye Stele models only) 2 0.9 20 90 1RC0449 All Roof Cub All Units 3 20 90 1RC0663 An ,C8 r14" M1Unlls f 3 20 90 1 WC0410 pp Wooden Crate r entry protection duMg sh1ptaq and handling All UNts 258 58 20 90 ' Please refer to propane conversion Idthrstrudions for proper natural gas to propane Id matchups. (;) z G; 3L ; " CASCADE CREST CONSULTDIG ENGINEERS- INC. PROJECT: So of (.1,3).tic 7,14LS ID Cr 7 4.4_. ("0■I11 <<ce3,9 L SLr`et,JC 4-'v rve>-- ENGR: DATE: 11,?..--- - SCALE: SHEET • • • 1rU-fZr)- -& EASC.JLIXt CRtsr Co►BULrtaG ENGINEERS. INC. PROJECT: Seem ct5a- S-o0-rtt ENGR: K -. \ DATE: T130 Ill SCALE: q/ SHEET HERMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -084 PROJECT NAME: SEARS SITE ADDRESS: 18350 OLYMPIC AV S DATE: 06/01/12 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEP1ng"tsion RTMENTS: Public Works Fire Prevention Structural Dai.lti • Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 06/05/12 Incomplete ❑ Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/03/12 Approved n Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 02/29/12 Contractors or Tradespeople Pr tter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LW to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name COMFORT MECHANICAL UBI No. 601954041 INC Phone 4252519840 Status Active Address 3202 C St Ne License No. COMFOMI015LA Suite /Apt. License Type Construction Contractor City Auburn Effective Date 6/1/1999 State WA Expiration 4/25/2014 Date Zip 98002 Suspend Date County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Business Type Corporation Specialty 2 Unused Parent Company ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FIVESM`010JT FIVE STAR MECHANICAL Construction Contractor General Unused 4/30/1999 5/1/2014 Active COMFOP'064D2 COMFORT PLUS Construction Contractor Air Conditioning Air Heat,Ventilation,Evaporat 3/22/1994 3/21/2000 Archived FIVESSE941KU FIVE STAR ENERGY SOLUTIONS Construction Contractor General Unused 5/24/20065/24/2008 Expired Business Owner Information Name Role Effective Date Expiration Date JACKSON, SHIRLEY A President 01/01/1980 Bond Amount JACKSON, HERB J Vice President 01/01/1980 9815017 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 Lexon Ins Co 9815017 06/01/2012 Until Cancelled $6,000.00 06/04/2012 2 COLONIAL AM CAS & SURETY OF MD LPM4041162 06/01/2002 Until Cancelled 06/01/2012 $6,000.00 05/15/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 Federated Mutual Ins Co 9849307 06/01/2010 06/01/2013 $1,000,000.00 04/24/2012 7 FEDERATED MUTUAL INS CO 9849306 06/01/2006 06/01/2010 $1,000,000.00 05/01/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni /bbip/Print.aspx 06/11/2012 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 07 2012 City of Tukwila BUILDING DIVISION Aresomssonswesemosiommorsomommow•rararrossomonut 1PARCEL DATA II Name I !Site Address Geo Area Parcel 788890-0155 C/O EPROPERTYTAX INC 18340 OLYMPIC AVE S 98188 70-60 [Spec Area Property Name 0-0 SOUTHCENTER SOUTH Jurisdiction !Levy Code Property Type Plat Block 1 Building Number Plat Lot 1 Unit Number I TUKWILA 12340 Quarter-Section-Township-Range ic 114-15-16-17 NE.35.23.4 !Legal Description IISOUTHCENTER SOUTH INDUSTRIAL PARK LOTS 19 & 20 AMEND TUKWILA SHORT PLAT NO MF 73-19-SS RECORDING NO 7807210798 SD PLAT DAF - BEG SW COR LOT 16 PLAT OF SOUTHCENTER SOUTH II INDUSTRIAL PARK TH N 78-36-10 W 360 FT TH N 11-23-50 E 698.25 FT TH ALG CURVE TO RGT RAD 110 FT PARC DIST 172.79 FT THRU C/A 90-00-00 TH S 78-36-10 E 480 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT THRU C/A 90-00-00 TH S 11-23-50 W 648.25 FT TH ALG CURVE TO LFT RAD 50 FT / RC DIST 78.54 FT THRU C/A 90-00-00 TH N 78-36-10 W TO POB ASSESSOR DATA \ \ \ \ • \\ \ i(E) VACANT SPACE RELOCATE RtU-2 \ "AREA OF WORK" SITE PLAN Map of: 18350 Olympic Ave S Tukwila, WA 98188-4723 VICINITY MAP PROJECT DESCRIPTION: 1 REPLACE (1) 3-TON HEAT PUMP PACKAGED ROOFTOP UNIT WITH (1) NEW 3-TON HEAT PUMP PACKAGED ROOFTOP UNIT (RTU-1) WITH ECONOMIZER AND NEW ROOF CURB. 2. REPLACE (1) 3-TON SPLIT SYSTEM HEAT PUMP SERVING 1ST FLOOR OFFICES WITH (1) "USED/PROVIDED BY OWNER" 3- TON HEAT PUMP PACKAGED ROOFTOP UNIT (RTU-2) WITH NEW ROOF CURB. 3. INSTALL DUCTWORK FROM RTU-2 AND CONNECT TO EXISTING DUCTWORK AT WAREHOUSE WALL. 4. NEW 7-DAY PROGRAMMABLE THERMOSTATS. GENERAL NOTES: 1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING. 2. THERMOSTAT TO PROVIDE MINIMUM 5° DEADBAND. 3. 7-DAY PROGRAMMABLE THERMOSTAT. 4. INSTALL GFCI OUTLET WITHIN 25° OF UNIT. 5. INSTALL RETURN AIR DUCT SMOKE DETECTOR FOR UNITS WITH GREATER THAN 2,000 CFM. 6. ROUTE CONDENSATE TO SPLASH BLOCK ON ROOF. 7. PROVIDE AIR BALANCE AND COMMISIONING REPORT. 8. VERIFY ALL DUCT DIMENSIONS PRIOR TO INSTALLATION. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. 10. INSULATE ALL DUCT PER WSEC TABLE 14-5. 11. SEAL ALL DUCT PER WSEC. EXISTING OFFICE SPACE EXISTING WAREHOUSE ....ww■sset AC-3 CONDENSING UNIT ON ROOF REMOVE (E) RTU-1 AC-3 AIR HANDLER "2ND FLOOR CEILING SPACE" EXISTING WAREHOUSE EXISTING WAREHOUSE HVAC Equipment Schedule Unit # Brand Model Ton 3.0 CFM 1200 OSA 120 Econo. 0-100 SP 0.5 Cap. Cool :, SEER 35,090 13.5 Cap. Heat 35,060 Strip Heat 5kw Weight 463 Dba 80 Location Roof HP-1 Carrier 50EZA36 HP-2 York B1HA036 3.0 1200 120 0-100 0.5 36,000 10.6 36,000 5kw 447 80 Roof RELOCATE (E) FROM VACANT SPACE RTU-2 CONNECT DUCT FROM RTU-2 TO (E) DUCT INTO 1ST FLOOR OFFICES EXISTING WAREHOUSE (E) HP-1 AIR HANDLER 2ND FLOOR EXISTING OFFICE 1ST FLOOR ELEVATION "RTU-2" PERMIT 11:01FIRED FOR: 0 Mechanical goriectrical eijornbing Mae Piping City of Tukwila LONG DIVISION REVISIONS No changes shaft be made to the scope of wort( without prior approval of Twfwila Building Division. r'. will require a new plan submittal may in:ude additional plan review fees. FILE COPY aot Permit No. tk 1 )-114'w tal 1,11 port roview approval Is subject to errors and omisslors. 01 construction documents does not authorize 1 v-,olation of any adopted code or ordnance. Receipt 1d opy and condWons Is acknowledged: By Date: (1 (0.- 11— 17_ City Of ltikvilla BUILDING DIVISION EXISTING WAREHOUSE REMOVE (E) "ABANDONED" SPLIT AC SYSTEM HP-2 AIR HANDLER HP-2 CONDENSING UNIT-ON ROOF [1 REMOVE (E) HP-2 "SPLIT SYSTEM" PARTIAL FLOOR PLAN/DEMO EXISTING OFFICE "NO CHANGE" NEW RTU-1 EXISTING WAREHOUSE RELOCATE (E) RTU-2 FROM ADJACENT VACANT RTU-2 OFFICE SPACE PARTIAL FLOOR PLAN/NEW • REV I S I ONS JUN 0 1 2012 PERMIT CENTER • z MECHANICAL, COMFORT F. 425.251.9871 w co > co < oT) 00) < ectir% u) < 1.1.1 op DATE SCALE. DRAWNI CHECKED t M1 00-000