Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M12-087 - SEGALE RETAIL CENTER
SEGALE RETAIL CENTER 300 ANDOVER PK W M12 -087 City otTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 2623049001 Address: 300 ANDOVER PK W TUKW Project Name: SEGALE RETAIL CENTER Permit Number: M12 -087 Issue Date: 06/22/2012 Permit Expires On: 12/19/2012 Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA WA 98138 Contact Person: Name: MICHAEL ATWOOD Address: 9630 153 AV NE , REDMOND WA 98052 Email: MAWWOOD@MERITMECHANICAL.COM Contractor: Name: MERIT MECHANICAL INC. Address: 9630 153 AV NE , REDMOND, WA 98052 Contractor License No: MERITMI163CM Phone: 425- 883 -9224 Phone: 425 883 -9224 Expiration Date: 06/01/2013 DESCRIPTION OF WORK: LIKE FOR LIKE REPLACEMENT OF (10) ROOFTOP GAS /ELECTRIC UNITS OF SAME MAKE AND CAPACITY Value of Mechanical: $83,119.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $1,145.56 International Mechanical Code Edition: 2009 L0iQL Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature Date:(, 42447, Print Name: Ale_ i7uo This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -087 Printed: 06 -22 -2012 • • PERMIT CONDITIONS Permit No. M12-087 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: IMC -4/10 M12-087 Printed: 06 -22 -2012 21: These plans were reviewed b (206)575 -4407. ector 511. If you have any questions, pleas1,1 Tukwila Fire Prevention Bureau at doc: IMC -4/10 M12 -087 Printed: 06 -22 -2012 CITY OF TUKWS- Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us • I Mechanical Permit No. V1, 1)4 97 Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: 300 Andover Park West Tenant Name: Segale Retail Center Property Owners Name: Segale Properties King Co Assessor's Tax No.: 2623049001 Suite Number: New Tenant: Mailing Address: 5811 Segale Park Drive, Suite C Tukwila Floor: ❑ Yes m ..No WA 98188 Zip City State CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Michael Atwood Mailing Address: 9630 153rd Ave NE Day Telephone: (425) 883 -9224 Redmond WA 98052 E -Mail Address: matwood @meritmechanical.com City State Fax Number: (425) 867 -0962 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: Merit Mechanical, Inc. Mailing Address: 9630 153rd Ave NE WA 98052 Contact Person: Michael Atwood (Same as Contact above) E -Mail Address: Contractor Registration Number: MERITMI163CM City Day Telephone: Fax Number: State Zip Expiration Date: 01/06/2013 ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD — All plans must be stamped by engineer of record Company Name: Mailing Address: Contact Person: E -Mail Address: H: \Applicanons\Fonns- Applications On Line \2010 Applications N7-2010 - Mechanical Permit Apphcanon.doc Revised: 7 -2010 bh City Day Telephone: Fax Number: State Zip Page 1 oft • Valuation of project (contractor's bid price): $ 83,119.00 Scope of work (please provide detailed information): Like for Like replacement of (10) Rooftop Gas /electric units of same make and capacity. Use: Residential: New Commercial: New Fuel Type: Electric m Replacement Replacement Gas IZI m Other: Indicate type of mechanical work being installed and the quant.ty below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor 0 -3 hp /100,000 btu Qty ! furnace <100k btu air handling unit >10,000 cfm fire damper furnace >100k btu evaporator cooler diffuser 3-15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended /wall /floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig /cooling system Incinerator — domestic other mechanical equipment air handling unit <10,000 cfm incinerator — comm/ind PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD I, G O ; OR AU ORIZED NT: Signature: Print Name: Michael Atwood Date: Day Telephone: (425) 883 -9224 Mailing Address: 9630 153rd Ave NE Redmond WA 98052 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H :\Applicanons\Fotms- Applicanons On Line \2010 Apphcanons \7 -2010- Mechanical Perndt Applicanon.doc Revised: 7 -2010 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049001 Address: 300 ANDOVER PK W TUKW Suite No: Applicant: SEGALE RETAIL CENTER RECEIPT Permit Number: M12 -087 Status: PENDING Applied Date: 06/06/2012 Issue Date: Receipt No.: R12 -01800 Payment Amount: $1,145.56 Initials: WER Payment Date: 06/06/2012 03:24 PM User ID: 1655 Balance: $0.00 Payee: MERIT MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 24675 1,145.56 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 916.45 000.345.830 229.11 Total: $1,145.56 doc: Receiot -06 Printed: 06 -06 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. • PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 tAA ■ -057 Project: •-,e_...‘,A. '47--e-T-A i L.. Type of Inspection: I:7 .1,44- Address: '230C.) Date Called: Special Instructions: • Date Wanted: a.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: .-1 nspefter: N Date: 4'7) -25- REIN (.-2— I. 1 /4 , ., ........ 1 A...Vt. e..k...4-...4Ce...1 ) ( . 1 - SPECTION FEE REQUIRED. Prior/to next inspection. fee must be .9 a d at 6300 Southcenter 131,4c1., Suite 100. Call to schedule reinspection. #3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Ci` (206) 431 -3670 M ►2 -0'`7 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Pro'ect: S 6::04 tL_ 2cJ A I Type of Inspection: , s itcokP _A r�-.' . Address: C, 0 ,J D OVF f VV ,. /4- Date Called: g.111 i-13 0 V- sild -r :1.ja w /i t ? `1-0AJ 1 _ ,AAA-6& Special Instructions: /� t O E '; /Zru'i Date Wanted: . 8— _/ -----a.m. -----a.m. 11.--- p.m. Requester: i -Ti f =- 0 A „ ! .- SI,tj , J)t J T1 . ;.,..A6 /v, Phone No: -442S -414 2- —5 o.31 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: (('' .� , / ZV .' 2 C94 .,,S14J�GC. ©li �l ' T A ele,6--- W wU A-C,AJ A 2t i i 41,, , K Sk✓Z'Jo off 17_--tviv n K POCW11 g.111 i-13 0 V- sild -r :1.ja w /i t ? `1-0AJ 1 _ ,AAA-6& ic- l 0 5 A K 5L J lit JV -'A 17 'rv--■ d --11/I A [ZZl 1 .r-9 A K--:' '. �L, ✓ i elui/t c9k.)k6A RI\ i *4 ,I i�- U.r,todA `hK frcAO^ re 1-1/ 4- eq k C AAD1114 • Q • ,friA-GA i -Ti f =- 0 A „ ! .- SI,tj , J)t J T1 . ;.,..A6 /v, (4ti (Ia. n KC.. Sktiraowl of,. A A(. A, Kral ?_, ( 56A ZI A n,,i A CI k. ,t4,46 A � A Inspe� ctor: akikA \ n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 — (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 AA 12- al Projec G 12... ` T� ) lsirDik`o--1-10 is Address: 00 DOUif V Date Called: — Special Instructions: h POOF r11/4) X171 ' Date Wanted:. 'tea m.. — I ( -' (�. p.m. Requester: Phone 7:= .4442._ j D 7 171. �pproved per applicable codes. Corrections required prior to approval. COMMENTS: 1 spec dr: 1 1 " 1../ eft, EINSPECTION FE EQUIREDL Prior to next inspection, fee must be id at 6300 Southce ter Blvd.. Suite 100. Call to schedule reinspection. Date: ter" %NM Y • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -087 DATE: 06 -06 -12 PROJECT NAME: SEGALE RETAIL CENTER SITE ADDRESS: 300 ANDOVER PK W X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Atid f t0 `� rl o" V USX I L �uliding Division Fire Prevention Public Works Structural Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: ig] Incomplete DUE DATE: 06-07-12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required nNo further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07-05-12 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 Contractors or Tradespeople P ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MERIT MECHANICAL INC UBI No. 600517946 Phone 4258839224 Status Active Address 9630 153Rd Avenue Ne License No. MERITMI163CM Suite /Apt. License Type Construction Contractor City Redmond Effective Date 2/14/1984 State WA Expiration Date 6/1/2013 Zip 98052 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AUTOMMC044QH AUTOMATED MECH CONTROLS INC Construction Contractor General Unused 11/8/1996 6/1/2010 Expired Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V President 02/14/1984 Bond Amount KIRKWOOD, JOAN M Secretary 02/27/2006 08358695 FRICKBERG, WILLIAM MICHAEL Vice President 02/27/2006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 10 FIDELITY Et DEPOSIT CO OF MD 08358695 02/01/2010 Until Cancelled $12,000.0001 /20 /2010 9 ARCH INS CO SU1041124 02/01/2009 Until Cancelled 02/01/2010 $12,000.00 01/12/2009 8 TRAVELERS CAS Et SURETY CO 081S103546895BCM 07/22/2001 Until Cancelled 02/01/2009 $12,000.0003/07 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 27 Travelers Property Cas Co of A VTC2JC0828K6148TILL1 11/01/2011 11/01/2012 $2,000,000.00 10/25/2011 26 LEXINGTON I INS 014180670 11/01/2010 11/01/2011 $2,000,000.00 10/29/2010 25 LEXINGTON IINS 049159165 11/01/2009 11/01/2010 $2,000,000.00 11/02/2009 24 LEXINGTON INS 004052434 11/01/2008 11/01/2009 $2,000,000.0011 /04/2008 23 ACE AMERICAN HDOG23734941 03/03/2008 03/03/2009 $2,000,000.0003 /10/2008 22 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2007 11/01/2008 $1,000,000.00 10/31/2007 21 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2005 11/01/2007 $1,000,000.0010 /18/2006 https://fortress.wa.gov/lni/bbip/Print. aspx 06/22/2012 ABBREVIATIONS 0 DIAMETER ABV ABOVE AD ACCESS DOOR AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT AP ACCESS PANEL BF BELOW FLOOR BFC BELOW FINISHED CEILING BOT BOTTOM CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE CG CEILING GRILLE CIP CAST IN PLACE CLG CEILING CONC CONCRETE CONN CONNECTION CTG CEILING TRANSFER GRILLE DB DRY BULB DIA DIAMETER DIFF DIFFUSER DN DOWN DWG DRAWING EA EACH EAT ENTERING AIR TEMPERATURE ENT ENTERING EQUIP EQUIPMENT ESP EXTERNAL STATIC PRESSURE EWT ENTERING WATER TEMPERATURE EXH EXHAUST FLR FLOOR FPM FEET PER MINUTE FT FOOT OR FEET FUT FUTURE GALV GALVANIZED GR GRILLE HP HORSEPOWER HT HEIGHT HVAC HEATING, VENTILATION AND AIR - CONDITIONING HWG HIGH WALL GRILLE HWR HEATING WATER RETURN HWRR HEATING WATER REVERSE RETURN HWS HEATING WATER SUPPLY HWTG HIGH WALL TRANSFER GRILLE IBC INTERNATIONAL BUILDING CODE ID INSIDE DIAMETER /DIMENSION IE INVERT ELEVATION IMC INTERNATIONAL MECHANICAL CODE IN INCHES IN WG INCHES WATER GAUGE LBS POUNDS LIN DIFF LINEAR DIFFUSER LIN FT LINEAR FOOT OR FEET LWG LOW WALL GRILLE LWR LOW WALL REGISTER MAX MAXIMUM MBH 1000 BRITISH THERMAL UNITS PER HOUR MD MIN MTD NC NO OBD OD OSA PCF PH POC PSI MOTORIZED DAMPER MINIMUM MOUNTED NORMALLY CLOSED NORMALLY OPEN OR NUMBER OPPOSED BLADE DAMPER OUTSIDE DIAMTER /DIMENSION OUTSIDE AIR POUNDS PER CUBIC FOOT PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE RA RETURN AIR REG REGISTER REQ'D REQUIRED RFA RELIEF AIR RPBP REDUCED PRESSURE BACKFLOW PREVENTER RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SL SOUND LINED SMACNA SHEET METAL AND AIR- CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION SQ FT SQUARE FOOT OR FEET SYM SYMBOL TDH TOTAL DYNAMIC. HEAD TG TRANSFER GRILLE TOT TOTAL TYP TYPICAL UNO UNLESS NOTED OTHERWISE UPC UNIFORM PLUMBING CODE VTR VENT THROUGH ROOF W WATTS OR WIDTH W/ WITH W/O WITHOUT WB WET BULB WG WATER GAUGE WSEC WASHINGTON STATE ENERGY CODE CODE COMPLIANCE NOTES GENERAL NOTES 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. '15. 16. COORDINATE ALL NEW UNITS WITH STRUCTURE AND OTHER TRADES. ROOM SENSORS TO BE MOUNTED ON WALLS APPROXIMATELY 54" ABOVE FINISHED FLOOR. HVAC EQUIPMENT WEIGHTS AND LOCATIONS TO BE APPROVED BY STRUCTURAL ENGINEER. FIELD VERIFY UNIT LOCATIONS, DROPS AND POSITIONS. GAS PIPING SHALL RUN BELOW THE ROOF. MAXIMUM FLEXIBLE DUCT LENGTH SHALL BE 12' -0 ". A 120 -VOLT RECEPTACLE SHALL BE WITHIN 25' OF EACH PIECE OF EQUIPMENT. DISCONNECT BY ELECTRICAL CONTRACTOR. AN ACCESSIBLE GAS SHUT -OFF VALVE SHALL BE INSTALLED WITHIN 3' OF ALL GAS APPLIANCES. SMOKE DETECTOR WIRE SHALL BE BY ELECTRICIAN; CONTROL SHALL BE BY FIRE AND LIFE SAFETY. ALL LINE VOLTAGE WORK SHALL BE BY ELECTRICIAN. ALL FIRE /SMOKE DAMPERS AND SMOKE DETECTORS SHALL BE POWERED BY OTHERS. ALL DUCT MOUNTED SMOKE DETECTORS SHALL BE SUPPLIED AND INSTALLED BY THE MECHANICAL CONTRACTOR. HVAC SYSTEMS HAVE BEEN DESIGNED PER THE REQUIREMENTS OF 2009 WSEC, IBC AND IMC. ALL DUCTWORK SPECIFIED SHALL BE BUILT IN ACCORDANCE WITH SMACNA STANDARDS AND IMC REQUIREMENTS; STATIC PRESSURES SHALL BE BASED ON DESIGN STATIC PRESSURE VALUES IN THE EQUIPMENT SCHEDULES. COORDINATE ALL PIPING AND VENTING WITH BELOW GRADE FOUNDATIONS, STRUCTURE, FIRE PROTECTION AND OTHER TRADES. PIPE DIAMETERS SHOWN ARE NOMINAL SIZES. CONTROLS SHALL BE CAPABLE OF PROVIDING 5 DEGREE DEAD BAND AS REQUIRED BY 2009 WSEC SECTION 1412.2. 2. CONTROLS SHALL BE CAPABLE OF PROVIDING SEVEN DAY PROGRAMMABLE TEMPERATURE SETTINGS AND SETBACK AND SHUTOFF AS REQUIRED BY 2009 WSEC SECTION 1412.4. 3. MOTORIZED AND GRAVITY DAMPERS SHALL BE PROVIDED AS REQUIRED BY 2009 WSEC SECTION 1412.4.1, INCLUDING MAXIMUM LEAKAGE RATES WHEN TESTED IN ACCORDANCE WITH AMCA 500 OF 10 CFM /SF OF DAMPER AREA AT 1 INCH WG FOR MOTORIZED DAMPERS AND 20 CFM /SF OF DAMPER AREA AT 1 INCH WG FOR NON- MOTORIZED DAMPERS EQUAL TO OR LARGER THAN 24 INCHES IN EITHER DIMENSION AND 40 CFM /SF OF DAMPER AREA AT 1 INCH WG FOR NON- MOTORIZED DAMPERS SMALLER THAN 24 INCHES IN EITHER DIMENSION. 4. CONTROLS SHALL BE CAPABLE OF PROVIDING OPTIMUM SYSTEM STARTUP AS REQUIRED BY 2009 WSEC SECTION 1412.4.2. HEAT PUMP CONTROLS SHALL BE CAPABLE OF MINIMIZING THE USE OF SUPPLEMENTAL HEAT AS DESCRIBED IN 2009 WSEC SECTION 1412.5. DEMAND CONTROL VENTILATION CONTROLS SHALL BE PROVIDED AS REQUIRED BY 2009 WSEC SECTION 1412.8. 7. AIRSIDE ECONOMIZERS SHALL BE USED AS A FIRST STAGE OF COOLING AND SHALL BE CAPABLE OF PROVIDING FULL OR PARTIAL COOLING CAPACITY DEPENDING ON THE COOLING DEMAND AND THE OUTSIDE AIR TEMPERATURE IN ACCORDANCE WITH 2009 WSEC SECTION 1413. 8. DUCT WORK SHALL BE SEALED AND PRESSURE TESTED AS REQUIRED BY 2009 WSEC SECTION 1414.1. DUCT WORK SHALL BE INSULATED AND PROVIDED WITH A VAPOR RETARDER AS REQUIRED BY 2009 WSEC SECTION 1414.2 AS TYPE SUPPLY RETURN OUTSIDE AIR SUPPLY RETURN OUTSIDE AIR LOCATION NOT IN CONDITIONED SPACE NOT IN CONDITIONED SPACE IN CONDITIONED SPACE IN CONCRETE OR IN GROUND IN CONCRETE OR IN GROUND IN CONCRETE OR IN GROUND R -VALUE 7 7 7 5.3 5.3 5.3 10. MECHANICAL PIPING SHALL BE INSULATED AS REQUIRED BY 2009 WSEC SECTION 1415.1 AS FOLLOWS: TYPE 180' HEATING WATER 180' HEATING WATER 40' AND OVER CHILLED WATER 40' AND OVER CHILLED WATER DOMESTIC HOT WATER DOMESTIC HOT WATER SIZE (INCHES) MINIMUM THICKNESS (INCHES) <4 1 -1/2 4 AND LARGER 2 <1 -1/2 1 1 -1/2 AND LARGER 1 -1/2 <1 -1/2 1 1 -1/2 AND LARGER 1 -1/2 FOLLOWS: 11. HEATING AND COOLING SYSTEMS SHALL BE CONTROL INTERLOCKED TO PREVENT SIMULTANEOUS HEATING AND COOLING AS REQUIRED BY 2009 WSEC SECTION 1422. 12. HEATING AND COOLING SYSTEMS HAVE BEEN SIZED IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES AND AS REQUIRED BY 2009 WSEC SECTION 1431.2. 13. SUPPLY AIR TEMPERATURE RESET SHALL BE PROVIDED AS REQUIRED BY 2009 WSEC SECTION 1432.2.1. 14. MAINTAIN 10' -0" MINIMUM DISTANCE BETWEEN OSA INTAKES AND PLUMBING VENTS, EXHAUST AND COMBUSTION AIR OUTLETS. HVAC - LEGEND m m or3-1( 0 I RG - 100 CD - 100 EG - 100 SLSM AIR FLOW DIRECTION SUPPLY OR OSA DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR SUPPLY OR OSA DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR ROUND DUCT SYMBOL RETURN AIR, NUMBER INDICATES CFM QUANTITY SUPPLY AIR, NUMBER INDICATES CFM QUANTITY EXHAUST AIR, NUMBER INDICATES CFM QUANTITY EXISTING DUCTWORK SOUND LINED SHEET METAL FC FLEXIBLE EQUIPMENT CONNECTION � SFD COMBINATION FIRE AND SMOKE DAMPER TFD FIRE DAMPER SD SMOKE DAMPER VD VOLUME DAMPER MD MOTORIZED DAMPER VD � I TURNING VANES ROUND TO ROUND 45' FITTING SQUARE TO SQUARE 45' FITTING SQUARE TO ROUND 45' FITTING 45' FITTING FOR DUCTWORK GAS PIPING THERMOSTAT TERMINAL UNIT REQUIRED EQUIPMENT CLEARANCE COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER 2009 WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416.3.4. AN OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER 2009 WSEC SECTION 1416.3.4. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER 2009 WSEC SECTION 1416.3.2. ALL HVAC SYSTEMS SHALL BE COMMISSIONED AND A CHECKLIST SHALL BE PROVIDED TO THE BUILDING OFFICIAL AS REQUIRED BY 2009 WSEC SECTION 1416.4. HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED. SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST RESULTS SHALL BE FILED WITH THE OWNER PER 2009 WSEC SECTION 1416.3.3 AND 1416.3.5. VICINITY MAP LEGAL DESCRIPTION COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT 'NY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. 300 ANDOVER PARK WEST TUKWILA, WA 98188 POR OF SE 1/4 OF NE 1/4 DAF - BAAP 30 FT S OF NW COR OF SE 1/4 OF NE 1/4 OF SD SEC TH S 88 -15 -33 E ALG S MGN OF STRANDER BLVD & W EXT THOF 578.68 FT TO TPOB TH CONT S 88 -15 -33 E ALG SD S MGN OF SD BLVD 76.63 FT TO NW COR OF LOT 5 ANDOVER INDUSTRIAL PARK NO 3 TH S 14 -39 -30 E ALG W LN OF SD LOT 5 89.17 FT TH ALG A CRV TO LFT ALG SD W LN OF LOT 5 HAVING RAD OF 410.28 FT TH ALG CRV 493.58 FT TAP ON N LN OF LOT 4 ANDOVER INDUSTRIAL PARK #5 TH N 84 -25 -51 W ALG N LN OF LOT 4 198.11 FT TH ALG CRV TO LFT ALG N & W LN OF SD LOT 4 HAVING RAD OF 410.28 FT TH ALG SD CRV 584.42 FT TH N 88 -16 -17 W 204.94 FT TH N 16 -06 -21 E 5.55 FT TH N 36 -31 -55 E 58.10 FT TH N 22 -46 -35 E 117.50 FT TH N 34 -41 -35 E 304.50 FT TH N 39 -31 -35 E 157.50 FT TH N 21 -01 -35 E 114 FT TH N 09 -28 -25 W 38.39 FT TO POB - -- CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO 86- 60 -BLA RECORDING NO 8612171456 TGW PORTION OF SE 1/4 OF NE 1/4 - DAF BAAP 30 FT S OF NW CORNER TH S 88 -15 -33 E 578.68 FT TO POB TH S 09 -28 -25 E 38.39 FT TH S 21 -01 -35 W 114 FT TH S 39 -31 -35 W 157.50 FT TH S 34 -41 -35 W 304.50 FT TH S 22 -46 -35 W 117.50 FT TH S 36 -31 -55 W 58.10 FT TH S 16 -06 -21 W 5.55 FT TH N 88 -16 -17 W 171.78 FT TO E MGN OF ANDOVER PARK WEST TH N 01 -05 -05 E 688.09 FT TH S 88 -15 -33 E 548.68 FT TO POB - -- CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO 86- 60 -BLA RECORDING NO 8612171456 PARCEL NUMBER: 2623049001 IF;Lti" Perm t No., n 1 007 PI *' rR►16W £,pproval is subject to errors and omissions. c Instruction documents does not authorize f _Apr, .a .rny rldopted code or ordinance. Receipt L4 iovec ie d ? opy and •' iitio - is acknowledged: By Date: (v(2Z(7�o[1 City Of Tiukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope tear { without prior approval of •takes la Gui ding Division. will rewire a new plan submittal may include add tional plan review fees. SEPARATE l E PERMIT REQUIRED FOR: 0 Mechanical 13' lectricai &Plumbing Ias Piping of Tukwila 7T,:.DIVISION REVIEWED FOR oDE COMPLIANCE APPROVED JUN 192012 tL-- City of Tukwila BUILDING DIVISION GENERAL LEGEND EQUIPMENT TAG TYPE EQUIPMENT TAG NUMBER DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL /DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION IS SHOWN C:r) e REVISION CLOUD AND CHRONOLOGICAL NUMBER DETAIL REFERENCE OUTLINE POINT OF CONNECTION TO EXISTING OR TO OTHERS' WORK C MECHANICAL SCOPE MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 (425) 883 -9224 FAX (425) 867 -0962 LICENSE: MERITMI163CM REMOVE AND REPLACE 10 ROOFTOP GAS /ELECTRIC PACKAGED HVAC UNITS WITH NEW UNITS THAT MATCH EXISTING IN MAKE AND CAPACITY: TWO 7 -1/2 TON UNITS EIGHT 12-1/2 TON UNITS REUSE EXISTING GAS PIPING, ELECTRICAL, CONTROLS, ROOF CURBS AND DISTRIBUTION DUCTWORK. BUILDING BUILDING OWNER'S REPRESENTATIVE SEGALE PROPERTIES 5811 SEGALE PARK DRIVE, SUITE C TUKWILA, WA 98188 (206) 575 -2000 STEVE NELSON RECEIVED JUN 06 2012 INFORMATION ZONING: CONSTRUCTION TYPE: OCCUPANCY TYPE: TUC MASONRY (SPRINKLER) RETAIL PEFZMIT (:tN I tK DRAWING INDEX DRAWING NO. DRAWING TITLE MO.1 MECHANICAL COVER SHEET MO.2 SITE AND ELEVATION PLAN M2.2 ROOF PLAN - HVAC REVISIONS 0. PERMIT DESIGNED ASA CHECKED DJ H DATE 6 -5 -2012 JOB NUMBER 912040 SHEET TITLE MECHANICAL COVER SHEET SHEET NUMBER M0.1 1 OF 3 RTU to 9A RTU 8A ROOF /RTU\ 7A NORTHWEST ELEVATION SCALE: 1/16" = 1' - /RTU\ 6A f %/ {ly RETAIL 2 STORIES § I • • Q d W I o • • RETAIL 1 STORY RESERVE/ WILDERNESS AREA STRANDER BLVD. RETAIL 1 STORY RETAIL 1 STORY 'Up HOTEL 3 STORIES 1 • N OFFICE 1 STORY TRECK DR. OFFICE 1 STORY RETAIL 1 STORY \ VACANT OFFICE 3 STORIES BANK 1 STORY RETAIL 1 STORY SITE PLAN SCALE: 1/64" = 1' - 0" VR2O87 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 19 2012 City of Tukwila BUILDING DIVISION RECEIVED JUN 06 2012 PERMIT CENTER COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. I— z W W W I" v za 0 W a °C 1.••• W � z -Ia W CO Q W 300 ANDOVER PARK WEST TUKWILA, WA 98188 MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 FAX (425) 8867?0962 LICENSE: MERITMI163CM REVISIONS 0. PERMIT DESIGNED ASA CHECKED DJH DATE 6 -5 -2012 JOB NUMBER 912040 SHEET TITLE ELEVATION & SITE PLAN SHEET NUMBER M0.2 2 OF 3 SL ITI- 800 SI_LLP CO„ \TRY 9 PACKAGED ROOFTOP UNIT SCHEDULE TAG MAKE & MODEL DESCRIPTION MINIMUM OUTSIDE AIR (CFM) FAN PERFORMANCE COOLING CAPACITY HEATING CAPACITY FILTERS ELECTRICAL DATA SOUND WEIGHT (LBS) REMARKS AIRFLOW (CFM) ESP (IN WG) BHP FLA TOTAL (MBH) SENSIBLE (MBH) SEER /EER MBH IN MBH OUT EFFICIENCY (%) GAS SIZE (IN) TYPE / SIZE VOLT PH MCA MOCP (DBA) RTU -1 CARRIER 48TCDA08B2A6 GAS /ELECTRIC ROOFTOP 960 3,000 1.00 2.28 3.4 95.2 70.9 /11.0 125.0 103.0 82 1/2 DISPOSABLE /4x 16x20x2 460 3 20.3 30 82 879 1, 2, 3 RTU -2 CARRIER 48TCED14B2A6 GAS /ELECTRIC ROOFTOP 1,000 4,800 0.60 3.63 4.4 148.0 103.8 /11.0 224.0 183.6 82 3/4 DISPOSABLE /4x 20x20x2 460 3 30.5 40 87 1,284 1, 2, 3 NOTES: 1. EQUIPMENT MAY BE SUBSTITUTED FOR EQUAL OR BETTER MANUFACTURER. 2. PROVIDE WITH DOWNFLOW SUPPLY AND RETURN, ECONOMIZER WITH BAROMETRIC RELIEF DAMPER, RETURN AIR SMOKE DETECTOR, MEDIUM STATIC FAN OPTION AND HINGED ACCESS DOORS. 3. REUSE AND RECONNECT TO EXISTING THERMOSTATS, DUCTWORK, ROOF CURBS, ELECTRICAL AND CONDENSATE DRAINS. S TI- 600 S I-- ATT L- I- L_ G I IT ACCESS TO ROOF. 4A C 4B 5A 5C 53 \G 0 -r S„ TI- 5C0 TOTAL W \ TIJ /RTu\ 6 /RTU REPLACE WITH RTU -2 REPLACE WITH RTU -2 /RTU\ � REPLACE WITH RTU -2 /RTU\ �6C� REPLACE WITH RTU -1 /RTU\ 7B REPLACE WITH RTU -2 0 /RTU\ �8A� REPLACE WITH RTU -2 /RTU\ �8B� REPLACE WITH RTU -2 RTU 8C REPLACE WITH RTU -1 ROOF PLAN - HVAC SCALE: 1/16" = 1' - 0" SLIT 0FFIC S�ITI- 45C VACA \T 0 /RTU)9A REPLACE WITH RTU -2 RTU 3 M REPLACE WITH RTU -2 3 9C COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. CC Imo W z W V 1 a 1 W CC W 1 a C'3 W u) 300 ANDOVER PARK WEST TUKWILA, WA 98188 13A REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 19 2012 City of Tukwila BUILDING DIVISION SPR \KLFR RS 8c AL_AR fV PA\ GENERAL NOTES: v -R R00 v - L_ L_O CAT I O 5 10B 2 1 0 C MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 (425) 883 -9224 FAX (425) 867 -0962 LICENSE: MERITMI 163CM REVISIONS 0. PERMIT DESIGNED ASA CHECKED DJ H DATE 6 -5 -2012 JOB NUMBER 912040 RECEIVED \ JUN 06 2012 PERMIT CENTER 1. REUSE THE EXISTING THERMOSTATS, DUCTWORK, ROOF CURBS, ELECTRICAL CONNECTIONS AND CONDENSATE PIPING FOR THE NEW UNITS. SHEET TITLE ROOF PLAN HVAC SHEET NUMBER M2.2 3 OF 3