Loading...
HomeMy WebLinkAboutPermit M12-090 - FULTZ RESIDENCEFULTZ RESIDENCE 12522 50 PL S M12 -090 J��If,IA h�q City oi'ukwila � sy Department of Communi h' Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0179002635 Address: 12522 50 PL S TUKW Project Name: FULTZ RESIDENCE Permit Number: M12 -090 Issue Date: 07/27/2012 Permit Expires On: 01/23/2013 Owner: Name: FULTZ PATRICK +LAUREL Address: 12522 50TH PL S , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Email: SHARYN.PARKER @KINGCOUNTY.GOV Contractor: Name: S K M CONSTRUCTION INC Address: 14415 SE 143 PL , RENTON, WA 98059 Contractor License No: SKMCOI *052L3 Phone: 206 - 296 -7437 Phone: 425 235 -5569 Expiration Date: 12/30/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Mechanical: $1,734.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $167.70 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Date: -7'oZ7/(Z. Print Name: st�G(�`flFf"'��� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12-090 Printed: 07 -27 -2012 • • PERMIT CONDITIONS Permit No. M12-090 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -090 Printed: 07 -27 -2012 CITY OF TUKWIL- Community Develop Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.ci. tukwila.wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 12522 50th PI. S. Tenant Name: Patrick and Laurel Fultz Property Owners Name: Patrick and Laurel Fultz Mailing Address: 12522 50th PI. S. King Co Assessor's Tax No.: 0179002635 Suite Number: Floor: New Tenant: ❑ Yes J .. No Tukwila WA 98178 CONTACT- PERSON City State Zip who do we contact when your permit is ready to be Issued``. Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip .;GENERAL CONTRACTOR INFORMATION :(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City State Contact Person: Day Telephone: E -Mail Address: Fax Number: Expiration Date: Zip Contractor Registration Number: • ARCHITECT.OF. RECORD -.A11 plans must be wet stamped by Architect of Record • Company Name: Mailing Address: SM Stemper Architects, PLLC 4000 Delridge Way SW, Suite 200 Seattle WA 98106. Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number. (206) 624 -2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 Valuation of Project (contractor's bid price): $ 25,860 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades, of existing systems and does not require any physical changes to the building.footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes I.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas to Square Footage Below ', Addition,to Existing Structure Type of', Construction. per IBC Type of Occupancy per IBC 1`Floor 992 2 11a Floor .: 3"1- Floor Floors Basemen 'Accessory: S tructure*.�: Attached Garage °i Detached :Garage:;; ;Attached C Detached Carport Covered Deck: Uncovered PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWotms- Applications On Line \2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 MECHANICAL PERMIT INF ATION — 206-431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ -731-1.00 Scope of Work (please provide detailed information): ._5 Use: Residential: New .... ❑ Replacement .. ❑ Commercial: New .... ❑ Replacement .... ❑ .. Fuel Type: Electric ❑ Gas .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 'l Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind H:\Applications\Forms- Applications On Line \2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 4 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A IT j ED AGENT: Signature: Print Name: Tim y J. enlas Mailing Address: 4000 Delridg SM Stemper Architects, PLLC ay SW, Suit &,200 Date: bi 2- Day Telephone: (206) 624 -2777 Seattle WA 98106 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\Applications\Forms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 Citii of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: hto://www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R12 -01839 Initials: WER Payment Date: 06/11/2012 User ID: 1655 Total Payment: 9,571.97 Payee: PAMELA KUEHL SET ID: 0611 SET NAME: KING COUNTY HOUSING SET TRANSACTIONS: Set Member Amount D12 -196 D12 -197 D12 -198 D12 -199 D12 -200 1,067.51 993.76 1,635.20 1,856.13 905.73 D12 -201 779.67 D12 -202 1,141.27 M12 -089 167.70 00112C101910 leiti kaila6w7A47o0 : M12 -091 M12 -092 M12 -093 M12 -094 M12 -095 177.10 177.10 167.70 167.70 167.70 TOTAL: 1,067.51 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 9,571.97 TOTAL: 9,571.97 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES MECHANICAL - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 000.322.102.00.0 000.345.830 640.237.114 TOTAL: 5,059.25 1,192.70 3,288.52 31.50 9,571.97 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C/ 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project:- Type of Inspection: Address: '7t I t �Z S0 —PL .s, Date Cal ed.:I/,, A v e:LI, _led u6({ �: Special Instructions: • P % Date Wanted:. a.m. �1 --J 'p Requester: .5-ft "C T r "C Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: .0? rA 1,0 -4 /) i r ( \ /0 Inspector: 6A--1/2(3) A Date: U n REINSPECTION FEE REQUIRED. Priori Ito paid at 6300 Southcenter Blvd., Suite 100. next inspection, fee must be Call to schedule reinspection. •PtNni �,vMCP) PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -090 PROJECT NAME: FULTZ RESIDENCE SITE ADDRESS: 12522 50 PL S X Original Plan Submittal Response to Correction Letter # DATE: 06 -08 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: r_��y 1 iiIding" Division lY� d`'� Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06 -12 -12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route IA Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07 -10-12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name S K M CONSTRUCTION INC UBI No. 601577401 Phone 4252355569 Status Active Address 14415 Se 143Rd Pl License No. SKMC01'052L3 Suite /Apt. License Type Construction Contractor City Renton Effective Date 6/23/1995 State WA Expiration Date 12/30/2013 Zip 98059 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SKMCO * *093L6 S K M CONSTRUCTION Construction Contractor General Unused 6/26/1991 6/17/1995 Archived SKMINI *976QL S K M INDUSTRIES INC Construction Contractor General Unused 11/13/2003 12/6/2009 Expired Business Owner Information Name Role Effective Date Expiration Date MORRISON, SHEILA K President 06/23/1995 Bond Amount MARKET SANDERS Agent 06/23/1995 06/25/2001 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 FIRST NATL INS CO OF AMERICA 6695979 06/17/2010 Until Cancelled $12,000.0004/26 /2010 4 DEVELOPERS SURETY e INDEM CO 188889C 12/30/2001 Until Cancelled 08/01/2010 $12,000.0012/05 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 15 James River Ins 00049593 08/21/2011 08/21/2012 $1,000,000.00 08/18/2011 14 COLONY INS CO EPK300402 08/21/2010 08/21/2011 $1,000,000.0008 /20/2010 13 CENTURY SURETY CO CCP616634 08/21/2009 08/21/2010 $1,000,000.0001 /20/2010 12 AMERICAN STATES INS CO 01CH6810051 01/25/2009 01/25/2010 $1,000,000.0001 /23/2009 11 AMERICAN STATES INS CO 01CH6810051 12/30/2008 01/25/2009 $1,000,000.00 12/23/2008 10 AMERICAN STATES INS CO 01CH6810051 12/30/2007 12/30/2008 $1,000,000.00 12/07/2007 9 AMERICAN STATES INS CO 01CD87273820 12/30/2006 12/30/2007 $1,000,000.00 12/19/2006 8 AMERICAN STATES INS CO 01CD87273810 12/30/2005 12/30/2006 $1,000,000.00 12/06/2005 https://fortress.wa.gov/lni/bbip/Print.aspx 07/27/2012 I.� ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CI RC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW H WC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN M TG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SRC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR WWB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SEATTLE RESIDENTIAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL 4 0 OR a. 0 X/Y DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS AND DETAILS. GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. REVISIONS No changes shall be made to the scope of work without prior approval of 'u`ct.wJiila Building Division. r.:lsicns will require a new plan submittal and may include additional plan review fees. SYMBOL SG -X xxX O- O4 - U.1 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD VOLUME DAMPER RA /EA RETURN AIR OR EXHAUST AIR DUCT RG RETURN AIR GRILLE SA SUPPLY AIR OUTLET, SIDEWALL SA SUPPLY AIR DUCT RA /EA RETURN AIR OR EXHAUST AIR DUCT SD SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH TOR Q THERMOSTAT EQUIP ID \ EQUIPMENT LOCATION NG • 3 0 MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 4 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 165 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 3 SG -1 165 <.08" WC 8" 8" CEILING ALLGRILLE 1, 2, 4 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3 RG -1 25 <O8" WG 4" 4" CEILING DECO 1, 2, 4 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2131 913 3 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION i MIN VALUE NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. FIL E COPY Permit No. 1 l X% 090 Finn rr° ►law approval is subject to errors and omissions. 'al of construction documents does not authorize t ,..Nation of any adopted code or ordinance. Receipt cif &pproved laid Copy and conditions is acknowledged: By Date: °1I I ca... City Of Tukwila BUILDING DIVISION THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. SEPARATE PERMIT REQUIRED FOR: 0 Mechanical C lectrical Etumbing E!eas Piping REVIEWED FOR CODE COMPLIANCE APPROVED JUN212012 CI ofTukwila BUILDING DIVISION S.M. STEMPER ARCHITECTS A Prutoodon.i rlm t.d Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 08100 (205) 624 -2777 • FAY (200) 024 -2975 THE GREENBUSCH GROUP, INC ,000 T ST L LIE 201 E w+ fell (200) 378 -0509 (205) 37e -0e41 FM of Tukwila MECHANICAL VEWILAINAPICALCULATION PER WAC 51 -51, SECTION M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE M1508.2) 4 &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1 /2) = 90 CFM RECEIVED 2,„ O/� O � � PERMIT �uw os CE202 NTER EXPIRES: 9/08/2012 0810.03.2131 TIONAL AIRPORT KING COUNTY INTERN RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3- 53- 0058 -044 DATE 3/1/2012 ISSUED GROUP 21 100% TUKWILAWASHINGTON PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.2131 NO MECHANICAL WORK THIS LEVEL STORAGE FUR CRAWL SPACE LOWER FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS RETURN AIR DUCT OUTSIDE AIR DUCT HOLD TIGHT TO STRUCTURE USE EXISTING ATTIC ACCESS HATCH FOR ELECTRICAL AND MAINTENANCE ACCESS NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. CU ATTIC MOTOR ACCESS FILTERS ACCESS BLENDING UNIT INSTALLATION DETAIL SCALE: NONE BEDROOM 3 RG- BATI -1 1 14' x 24' EXIST. ATTIC ACCESS PANEL RG 1 25 BEDROOM 2 1- W 0 1 U 4- N 0 1 0 LAUNDRY ROOM RG -1 25 KITCHEN BEDROOM SHEETMETAL TRANSITION TO GRILLE NECK SIZE 165 SEE TYP ALL CEILING GRILLES LIVINGr ROOM TYP MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" DUCT PER PLAN 2X BLOCKING FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON 2X BLOCKING WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORD. W /ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL SCALE: NONE SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE 2X BLOCKING r r r 4 "0 DN L TO RG -1 r 4 "0 C L JL 14' x 24' EXIST ATTIC ACCESS PANEL 4 „0 4 "0 DN TO RG -1 n I I 11 _J L_ DUCT PER PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE ATTIC MECHANICAL PLAN 8 "0 DN TO SG -1 L J FIELD FABRICATE PLENUM BEHIND CEILING GRILLE FOAM BACKER ROD CAULK 2X BLOCKING SLEEVE AND ESCUTCHEON GRILLE NOTES: FLOOR OR CEILING JOIST CEILING SCALE: 1 /4" = 1' -0” 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL SCALE: NONE DRAWING NOTES: NORTH 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51 -51, SECTION M1508.6.6. 2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK -OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND /OR BLENDING AIR UNIT SYSTEMS WITH NEW FILTERS. FLAG NOTES: 13V -1. AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL A MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNIC SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -51, SECTION M1508.6.4. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. VtI2O96 REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 2 1 2012 L City of rukwil l BUILDING DIVISION AIR RECEIVED JUN 08 2012 PERMIT CENTER S.M. STEMPER ARCHITECTS A Professional limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, NA 96106 (206) 824 -2777 • PAX (806) 924 -2973 THE GREENBUSCH GROUP, INC 0••••••••)) (26 31-8m 8 9 Deo T & I (2C0H8M) l C 3 7J. 6 SVGA EXPIRES: EXPIRES: 9/08/2012 0810.03.2131 TIONAL AIRPORT KING COUNTY INTERN CO z w w 0 0_ >- w 0 w W U) O z LL J z w w AIP NUMBER 3 -53 -0058 -044 DATE 3/1/2012 ISSUED GROUP 21 100% PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT ILA WASHINGTON MECHANICAL PLANS AND DETAILS M2.0 0810.03.2131