Loading...
HomeMy WebLinkAboutPermit M12-098 - HARDGRAVE RESIDENCEHARD GRAVE RESIDENCE 13757 MACADAM RD S M12 -098 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 3229200047 Address: 13757 MACADAM RD S TUKW Project Name: HARDGRAVE RESIDENCE Permit Number: Issue Date: Permit Expires On: M12 -098 06/18/2012 12/15/2012 Owner: Name: Address: Contact Person: Name: Address: Email: RICHARDSON STEFANIE A 13757 MACADAM RD S , TUKWILA WA 98168 STEPHANIE HARDGRAVE 13757 MACADAM RD S , TUKWILA WA 98168 NOT PROVIDED Contractor: Name: GREENWOOD HEATING & A/C Address: 2850 YANCY ST PMB 203 , SEATTLE WA 98126 Contractor License No: GREENHA922U7 Phone: 206 - 979 -4762 Phone: 206 - 365 -3313 Expiration Date: 02/03/2013 DESCRIPTION OF WORK: REPLACE GAS FURNACE, LIKE FOR LIKE. LENNOX ML180UH070E36B, 80 %, 70,000 BTU'S Value of Mechanical: $1,750.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $167.70 International Mechanical Code Edition: 2009 Date: 1Q.1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: %14// V11"' v Date: G Print Name: Mt This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -098 Printed: 06 -18 -2012 • • PERMIT CONDITIONS Permit No. M12-098 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -098 Printed: 06 -18 -2012 CITY OF TUKWI Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: to rY1acAacLrn �RdS PROPERTY ,OWNER Name: phG,Y11'e, NA a.rozyrow Address: 15-4 5.3 Not.Aaamis City: liA,1C■1a State: 1,0,p,, Zip:Q % 1 j6 CONTACT PERSON - person r communication Name:cJiGPhG1.n % e- NA-Ar-acyro.. C�. Address: 1-6 - e.} MeAcAtScurYNS City: TV��C v►71 01 State: w A Zip: t 81 a , Phone:lolYq,}ei.. t ax: Email: King Co Assessor's Tax No.: 3'2.Zq ? O ('CA -{." -' Suite Number: Floor: New Tenant: ❑ Yes ❑ ..No Company Name: Green‘ocect a.A.%■r,o‘ ift C Address: gas S. tivju1/4 St te: W Zip: (1%14 City:�CA Q Phone: p t �1�S Fax: 20'o 14to2. • (.42 tto Contr Reg No.: Exp Date: Gag OMHA92.ZVt"'I- 2 f 3 f 13 Tukwila Business License No.: Valuation of project (contractor's bid price): $ rfSO Describe the scope of work in detail: CC C.Q OOOIS AArnacQ , l Oct. 4-O r 1 i ka , L,Q(Anci)C '60°10 00C> em i1/4 Use: Residential: New ❑ Replacement Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas Val L I $ b U, H 01-b63413, Other: 1-1 \ Applications \Forms - Applications On Line 2011 Applications \Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended /wall /floor mounted heater Appliance vent Repair or addition to heat/refrig /cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLIC;4T] Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER AUTH ZED AGENT: Signature: 1 Print Name: Mailing Address: ta_J S 1 S} H \Applications \Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8 -9 -11 docx Revised: August 2011 bh Date: Le 13 • ( Day Telephone: 2,0 ( "r-%14 $ I a 9 813 City State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.00v Parcel No.: 3229200047 Address: 13757 MACADAM RD S TUKW Suite No: Applicant: HARDGRAVE RESIDENCE RECEIPT Permit Number: M12 -098 Status: PENDING Applied Date: 06/18/2012 Issue Date: Receipt No.: R12 -01895 Initials: WER User ID: 1655 Payment Amount: $167.70 Payment Date: 06/18/2012 10:58 AM Balance: $0.00 Payee: GREENWOOD HEATING & AC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 13933 167.70 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - RES 000.322.102.00.00 167.70 Total: $167.70 doc: Receipt -06 Printed: 06 -18 -2012 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 _ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: '' 4r4VL.- Kr,�S) AzAC� Type of Inspection: ' j --- - ' ad__ M. e cA A dress: Date Call d: Special Instructions: Date Z Wanted Z-- " tf -,: p.m. Requester: 6 Phone No: 2,0 67 – `724 -23 (3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: r). 2 -M.\,-{ d ( r, 1 Date ,� L, n REINSPECTION FEE REQUIRE 1 : rior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ,w- ..,•._ ._,_.�.:......,..u_�v�_, -J,-.. ....,K -n -. _ �: Caw'-- Y"".- `--_Y- .._.. ...— ...... r Contractors or Tradespeople Primer Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name GREENWOOD HEATING & A/C UBI No. 602259014 Phone 2063653313 Status Active Address 2850 Sw Yancy St Pmb 203 License No. GREENHA922U7 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 3/27/2008 State WA Expiration Date 2/3/2013 Zip 98126 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name yP Type Specialty 1 P y Specialty 2 P y Effective Date Expiration Date Status SELECAS972BW SELECT AIR SERVICES INC Construction Contractor Air Conditioning Metal Fabrication 1/16/2003 1/16/2005 Archived GREENAS952CC GREENWOOD AIRE SERV Construction Contractor Air Conditioning Unused 2/3/2005 2/3/2009 Inactive Business Owner Information Name Role Effective Date Expiration Date PORTER, MICHAEL Owner 03/27/2008 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 CBIC SI4989 01/14/2010 Until Cancelled $12,000.0001/13 /2010 3 HARTFORD FIRE INS 45BSBEZ5127 03/21/2008 Until Cancelled 03/21/2010 $12,000.00 03/27 /2008 2 FIRE INS CO 45BSBEJ2369 45BSBEJ2369 01/14/2007 03/21/2008 $6,000.0005/21/2007 3 1 HARTFORD FIRE INS 45BSBBZ8401 01/14/2003 Until Cancelled 05/03/2007 $1,000,000.0001 /09/2006 $6,000.0001/16/2003 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 Mid-Century Ins 604663707 08/01/2008 08/01/2012 $2,000,000.0007 /14/2011 5 NATIONWIDE MUTUAL INS CO ACPACT0712203883601/15/2008 01/15/2009 $1,000,000.0001 /07/2008 4 AMCOINSCO ACT07102038836 01/15/2007 01/15/2008 $1,000,000.0001 /11/2007 3 ALLIED INS 104711 01/15/2005 01/15/2007 $1,000,000.0001 /09/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information Infraction / Citation 1 Date 1 RCW Code I Type i Status I Violation Amount https: // fortress .wa.gov /lni /bbip /Print.aspx 06/18/2012