HomeMy WebLinkAboutPermit M12-101 - DUPONTDUPONT
13028 INTERURBAN AV S
M12 -101
City oPi'ukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206.431 -3670
Inspection Request Line: 206 -431 -2451
Web site: http: / /www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No.:
Address:
0004800017
13028 INTERURBAN AV S TUKW
Project Name: DUPONT
Permit Number: M12 -101
Issue Date: 06/27/2012
Permit Expires On: 12/24/2012
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Email:
Contractor:
Name:
Address:
Contractor
EPROPERTY TAX INC DEPT #207
PO BOX 4900 , SCOTTSDALE AZ 85261
ALEX BURKHART
727 S KENYON ST , SEATTLE WA 98108
AL EXB @ E V ER G RE ENH VAC . C O M
EVERGREEN REFRIGERATION LLC
727 S KENYON ST , SEATTLE WA 98108
License No: EVERGRL954R2
Phone: 206 763 -1744 X 247
Phone: 206 763 -1744
Expiration Date: 01/06/2014
DESCRIPTION OF WORK:
INSTALLATION OF TENANT IMPROVEMENT DUCTWORK, GRILLES, AND DIFFUSERS.
Value of ,
f Mechanical: $4 768 00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
"
Permit Center Authorized Signature: 4 At ate:
I hereby certify that I have read and examined this pe and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether s ified herein or not.
Fees Collected: $244.88
International Mechanical Code Edition: 2009
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Signature: S^
Ata. 13t�11,►loort-
Print Name:
Date: G 1 1-7
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M12 -101
Printed: 06 -27 -2012
• •
PERMIT CONDITIONS
Permit No. M12-101
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IMC -4/10
M12 -101 Printed: 06 -27 -2012
CITY OF TUKW40
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TulcwilaWA.gov
Mechanical Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *please print **
SITE LOCATION
Site Address: 13 2 „1-in+`-ru+' 6an A `> t S
Tenant Name: DL, pal
King Co Assessor's Tax No.: 000 ' 2 600 11
Suite Number: 12-14 Floor:
New Tenant: [' Yes ❑..No
PROPERTY OWNER
Name:A le,„ j3 is
Name:
FProratr 7Tax Tom. bcp+
City: S� State: v/A Zip: q g 1 o 0
Address: p, p . (D I( Woo
()
u17
Email: ff
�te,16 0evervl�tite ,L. co,,,,‘
City: 5 Lo'f5 L/k State: A-2_
Zip: 1 526
CONTACT PERSON — person receiving all project
communication
Name:A le,„ j3 is
Address:
7 2,,-7 2,,-7 �x...1 ... Y. .
City: S� State: v/A Zip: q g 1 o 0
Phone: -2/06 ,...-163 - tri Ll �a" : 2D- 7(3 ..Z3 b 1
u17
Email: ff
�te,16 0evervl�tite ,L. co,,,,‘
MECHANICAL CONTRACTOR INFORMATION
Company Name: G
Address: 724 � ,,,. S'_ •
City: Svc✓�'�c State: QA. Zip: lg 1t
Phone: -2,06 _16,3_ l7 Li U Fax: "2/06 _ -7,3 —23 ii °I
Contr Reg No.: F V 6i2 G_r_i A 5q rz1 Exp Date: l / cs / l y
Tukwila Business License No.: n CiA Z 7
Valuation of project (contractor's bid price): $ 17 G o Q)
Describe the scope of work
�Iindetail:
OiirV�O✓
Use:
Residential:
New ❑ Replacement ❑
New ❑ Replacement ❑
Fuel Type: Electric ❑ Gas ❑
t / (/ f .v5
Other:
H:WpplicattonsTorms- Applications On Lmet201 I Apphcattons'Mechanical Pernut Application Revised 8 -9 -I I.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
•
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler /Compressor
Qty
0 -3 hp /100,000 btu
3 -15 hp /500,000 btu
15 -30 hp /1,000,000 btu
30 -50 hp /1,750,000 btu
50+ hp /1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name: R04-
Mailing Address: �7 $ - -
H:\Applications \Forms- Applications On Line \2011 Applications\Mechamcal Permit Application Revised 8- 9- 11.docx
Revised: August 2011
bh
Date:
6/2 12
Day Telephone: 2/D6 - 7G-3 — 74 -(14 e�` • 141-7
Sea *-c. L.A I BlD$
City State Zip
Page 2 of 2
Ci, of Tukwila.
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206-431-3665
Web site: hup://www.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R12 -01961
Initials: JEM
Payment Date: 06/22/2012
User ID: 1165 Total Payment: 312.08
Payee: EVERGREEN REFRIGERATION, LLC
SET ID: S000001764 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member
EL12 -0578
M12 -101
TOTAL:
Amount
67.20
244.88
67.20
TRANSACTION LIST:
Type Method Description Amount
Payment Check 005443 312.08
TOTAL: 312.08
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
MECHANICAL - NONRES
PLAN CHECK - NONRES
000.322.101.00.0
000.322.102.00.0
000.345.830
67.20
195.90
48.98
TOTAL: 312.08
INSPECTION RECORD
Retain a copy with permit M t 2-' 101
INSPECTION NO: PERMIT N0. V
_-CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 . (206) 431 -3670
-Permit Inspection Request Line (206) 431 -2451
Proj ct:
+� a N-:
Type ftlnspectio
a1
.,Q ¢hr-
Address: _ 1
i 30 2.-g 7-Artiji.AAI
Date Called:
Special Instructions:
Date Wanted:
`7-3
.m\.;
•-(Z__ p.m.
Requester:
Phone No
7/0
--(o7q -3139
Approved per applicable codes. E Corrections required prior to approval.
COMMENTS:
InspeEtor:
n
Date.;—,
eLAA t -- - Z---
v \'\ jt
REINSPECTION FEE REQ IRED_Pr1ior to next inspection, fee must be
I I paid at 6300 Southcenter Suife 100. Call to schedule reinspection.
INSPECTION NO.
,,INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451 �?
Projec
U'V
Type of, Inspection:
A;i-( AA ems. •
Address:
028 _V .JJ 4),w
Date Called:
Special Instructions:
Date Wanted:
Requester:
Phone No:
3 3 7
EiApproved per applicable codes. - Corrections required prior to approval.
COMMENTS:
1Ji:t �
$
�r� ( 7ar -r
• f G. A ei '7 coJt
Inspector:
Date
7.
n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite. 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 j, (206) 431 -367
Permit Inspection Request Line (206) 431 -2451
Project:
Type of Inspect' n:
Address: '
1 30 ZS' -d,)i 1: 1\
Date Called:
Special Instructions:
Date Wanted:.
6- 27 -rZr
a.m.
Em
Requester:
`
Phone No:
ElApproved per applicable codes.
0 Corrections required prior to approval. S
COMMENTS:
A
Inspec3�or:
1 A II
DateJ` ' 7A'
r7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 14, (206) 431 -36
Permit Inspection Request Line (206) 431 -2451
PERMIT NO.
0
Project:
Type of In ectigy
Address: l;
f 3 0-
T
U J64it/
Date Called:
Special Instructions:
_
Date Wanted:.//�
tiCJ
ca.m
r p.m.
Requester:
Phone No: t
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
Ins ector:
04 Iv-,
Date(.. ( 7
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
• paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
.1
EVERGREEN REFRIGERATION, LLC
727 S KENVON ST.
SEATTLE, WA. 98108
206- 763 -1744
CONTR. # EVERGl201 D7
TEST AND BALANCE REPORT
Project: Dupont TI Gateway Corporate Park
Evergreen Job #:
Date:
Location:
412122
June 29, 2012
13028 Interurban Ave S
Tukwila, WA 98168
JUL cniN
067012
►'ERMRCEN1gR
Engineer: EVERGREEN REFRIGERATION LLC
Evergreen Refrigeration LLC, has balanced the system described in accordance
with the plans, specifications, and within the limitations of the equipment.
The testing, balancing, and adjusting has been performed in accordance with
industry standards. The results of these tests are herein recorded.
Commissioning Technician: %a.ly/►
Date completed: 2 `2 / / Z
47
AIR OUTLET TEST REPORT - SUPPLY
EVERGREEN REFRIGERATION, LLC
Page 1
Project: Dupont TI Gateway Corporate Park
Job #: 412122
Date: 6/29/12
Unit #
Area Served
Outlet
Design
Target
Preliminary
Final
No
Type
Size
C.F.M.
C.F.M.
C.F.M.
C.F.M.
C.F.M.
TTu II /
I l
5/►�t1ef/ iih'y
5), l
ite.b
13
220
51.2
nie b
/0
yy0
5i.3
/nab
/2-
35s
51. V
&KJ)
/0
2130
7 L/ t. rill
i2.95
I4TG.It2
E • ?ec;rn eJer
52./
f ul
I0
35-0
52.Z
,nab
8
4210
52 .3
,4c):.
a
205-
52.4/
mc.
4
it S
52. S
ncc%
Co
>co
ecm 74,1
9e8
A) /re
53. /
rnrl3
10
200
Rru 3
53.2
,A
8
27C
53.3
n3c 6
10
25S
53.y
10
1604
960
1
PERMIT COORD COP
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M12 -101 DATE: 06/22/12
PROJECT NAME: DUPONT
SITE ADDRESS: 13028 INTERURBAN AV S
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
DEPARTMENTS:
�uilding �bivisi(C31
Public Works
Ait
Fire Prevention
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete gj
Comments:
Incomplete
DUE DATE: 06/26/12
Not Applicable n
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route 1X,
REVIEWER'S INITIALS:
Structural Review Required
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 07/24/12
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Contractors or Tradespeople Pri r Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with MI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name EVERGREEN REFRIGERATION LLC UBI No. 602512953
Phone 2067631744 Status Active
Address 727 5 Kenyon St License No. EVERGRL954R2
Suite /Apt. License Type Construction Contractor
City Seattle Effective Date 1/6/2006
State WA Expiration Date 1/6/2014
Zip 98108 Suspend Date
County King Specialty 1 General
Business Type Limited Liability Company Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
EVERGHH910J0
EVERGREEN HOME
HEATING & ENGY
Construction
Contractor
General
Unused
4/20/2009
4/20/2013
Active
EVERGI'201D7
EVERGREEN
REFRIGERATION INC
Construction
Contractor
General
Unused
3/27/1980
7/31/2006
Re
Licensed
Business Owner Information
Name
Role
Effective Date
Expiration Date
EVERGREEN REFRIGERATION LLC
Partner /Member
12/22/2005
Bond Amount
PATTON, DAVID
Partner /Member
01/06/2006
WA15097
PATTON, RODGER
Partner /Member
01/06/2006
PATTON, MATTHEW
Partner /Member
01/06/2006
TRAVELERS CAS &
SURETY CO
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
2
Merchants Bonding Co
(Mutual)
WA15097
01/01/2012
Until Cancelled
$12,000.00
12/15/2011
1
TRAVELERS CAS &
SURETY CO
104667361
01/01/2006
Until Cancelled
$12,000.00
01/03/2006
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
3
AMERICAN FIRE
AND CASUALTY
COM
BAW54192293
07/31/2010
07/31/2012
$1,000,000.0007
/27/2011
2
Continental
Western Ins Co
CWP2640663
07/31/2006
07/31/2010
$1,000,000.00
03/23/2009
1
ALASKA
NATIONAL
INSURANCE CO
05GLS31381
07/31/2005
07/31/2006
$1,000,000.0001
/03/2006
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
06/27/2012
VICINITY MAP
SCALE : NONE
•
L
L
L -
E
N
L
E
HVAC FLOOR PLAN
SCALE : 1/8" = 1' -0"
COMPLETION AND COMMISSIONING FOR
MECHANICAL SYSTEMS
RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE
BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE
PER WA ENERGY CODE (WSEC) SECTION 1416.3.4.2
AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE
BUILDING OWNER PER WSEC SECTION 1416.3.4.1 .
ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE
PROVIDED TO THE OWNER PER WSEC SECTION 14516.3.2.1.
FOR WAREHOUSES SEMIHEATED SPACES AND SIMPLE SYSTEMS (AS DEFINED IN
WSEC SECTION 1421): HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND
ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY
OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE
REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER
PER WSEC SECTION 1416.3.3.
FOR ALL OTHER SYSTEMS; HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED
AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY
OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.3.3.
NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.3.3;
A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE
PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION
1416.3.4.1 AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST
PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.4
No changes REVISIONS
i irk without hall tie made to the scope
Tukwila tdinor approval of
NOTE: Revisions will require 9 Division.
and may include addittionl new plan submittal
Ptah review fees.
FILE COPY
it No.
Ron rl+vlew approval Is } i to
4:- ./a1 of construction docu
fl. JictiOn of any a
of 4)proved Reid Copy and
By_ dix-el/V--
awl
not authorize
Receipt
City Oflikwila
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 6 2012
City of Tukwila
BUILDING DIVISION
GENERAL NOTES
DUCTWORK
1.1
ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH
DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4 "TO EACH DIMENSION IF
DUCTWORK IS ON THE EXTERIOR OF BUILDING.
1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND
NUMBER IS THE HEIGHT.
1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING
LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER
IMC 602.2.1.
1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN
1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT
PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED
IN ACCORDANCE WITH STANDARD RS -7. .
1.5 ALL DUCT GAUGES PER SMACNA, IMC 603 -4;
1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10.
1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES.
1.8 • BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS.
INSULATION
2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES.
2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES.
GENERAL CONTRACTOR
3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP
CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING
AND FIRE PROOF LINING PER IMC & IBC.
3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS
WITH ERL BEFORE FRAMING OPENINGS.
3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING
AS REQUIRED FOR MECHANICAL WORK.
3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS
REQUIRED FOR MECHANICAL WORK.
3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR
MECHANICAL WORK.
GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL
MECHANICAL EQUIPMENT.
3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE
ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS.
3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING
AS REQUIRED FOR HVAC INSTALLATION.
3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED
FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL
BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC.
ELECTRICAL
4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED
BY ELECTRICAL CONTRACTOR.
4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS,
DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. .
4.3 ELECTRICAI. CONTRACTOR TO VERIFY EQUIPMENT SIZES LOADS AND LOCATIONS
WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS.
4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT
SWITCH.
4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH
CAPABILITY OF 5 °F DEADBAND.
4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER.
4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT
OF EACH PIECE OF MECHANICAL EQUIPMENT.
3.6
PLUMBING
5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR
MECHANICAL EQUIPMENT PER CODE.
5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH
AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1.
5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT.
CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER.
ENERGY CODE COMPLIANCE
6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY
THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS.
6.2 •OUTSIDE AIR INTAKES, EXHAUST OUTLETS AND RELIEF OUTLETS SERVING
CONDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE
AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE,
PER WSEC' _C. 1412.4.1.
6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT
SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER
SHALL COMPLY WITH WSEC SEC. 1423.
MECHANICAL CODE COMPLIANCE
7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS
IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM.
DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606.
WA2004 #1
SYMBOL LEGEND
SYMBOL
ABBV.
DESCRIPTION
z
DUCT SECTION SUPPLY
ra
DUCT SECTION - RETURN /EXHAUST
RECTANGULAR DUCT
ROUND DUCT
.
FLEXIBLE DUCT
MVD
MANUAL VOLUME DAMPER
L
❑ BOB
BDD
BACKDRAFT DAMPER
I
4
r
MD
MOTORIZED DAMPER
FD •
FIRE DAMPER
FSD
FIRE /SMOKE DAMPER (I20V POWER REQ.)
-®-4
CEILING RADIATION DAMPER
sn
SD
SMOKE DETECTOR
TO
T
THERMOSTAT
S
SENSOR
R
REFRIGERANT LINES
-R- - - -R
G-
G
NATURAL GAS LINES
- - - -r,
ra
CEILING DIFFUSER (SUPPLY)
CEILING DIFFUSER (RETURN /EXHAUST)
D
EXHAUST FAN (CEILING MOUNTED)
[L°J
-]
INLINE FAN E
PROPELLER FAN
JUN 2 2 2012
� I /
SIDEWALL DIFFUSER BERMITCEiER
L
DUCT FITTING
B.O.J. 12' 2' -"949
DATUM
la
VI
UNIT TAG
2........ t-o-
DUCT RISER
U
0
ria;
z
NOT PUBLISHED. ALL RIGHTS RESERVED. THE
DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS
AND ARRANGEMENTS REPRESENTED THEREBY
ARE AND SHALL REMAIN THE PROPERTY OF EVE-
RGREEN REFRIGERATION INC. NO PART THEREOF
SHALL BE REPRODUCED, COPIED, ADAPTED, DISC-
LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB-
LISHED OR OTHERWISE USED WITHOUT THE PRIOR
WRITTEN CONSENT OF AND APPROPRIATE COMPEN-
SATION TO EVERGREEN REFRIGERATION INC. VISUAL
CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC-
ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE
OF ACCEPTANCE OF THESE RESTRICTIONS.
a)
a0
nl
''�l•
SEATTLE. WASHINGTON 98108
727 SOUTH KENYON
EVERGRL954R2
ZZ
0
N
•D
0
L�J
0
NOT FOR CONSTRUCTION
W
d
N
g
(
F-
Z
Z
0_
W
Ct O
CL <
•
ooa
W
E-
d
0
CONSTRUCTION DRAWINGS
LLI
0
AS BUILT DRAWINGS
GATEWAY CORP PARK
DUPONT T
HVAC COVER SHEET
u)
z Co
�/� CO
I.L. O)
:D <
ct
W
w
�
CO
N
c
F.-
REVISIONS
NO
DATE
ITEM
DRAWING DATE:
06/20/12
DWG. BY
GN
CHK. BY:
DP
JOB NO.:
412122
DWG. FILE:
412122M1
SHEET:
M1
OF 1 SHEETS