HomeMy WebLinkAboutPermit M12-104 - HILL ROMHILL-ROM 12610 INTERURBAN AV S M12 -104 City di/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 0004800003 12610 INTERURBAN AV S TUKW Project Name: HILL -ROM Permit Number: M12 -104 Issue Date: 07/18/2012 Permit Expires On: 01/14/2013 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: Contractor GATEWAY OLYMPIA INC PO BOX 4900 #207 , SCOTTSDALE AZ 85261 ALEX BURKHART 727 S KENYON ST , SEATTLE WA 98108 ALEXB@EVERGREENHVAC .COM EVERGREEN REFRIGERATION LLC 727 S KENYON ST , SEATTLE WA 98108 License No: EVERGRL954R2 Phone: 206 763 -1744 X 247 Phone: 206 763 -1744 Expiration Date: 01/06/2014 DESCRIPTION OF WORK: INSTALL (1) DUCTLESS SPLIT SYSTEM UNIT, ONE EXHAUST FAN, AND DUCTWORK. Value of Mechanical: $6,938.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie xan wit Fees Collected: $269.31 International Mechanical Code Edition: 2009 Date: 0104 ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: ditrcr)2A---- Print Name: F i sk 13 km-01— A- 2 Date: /Ig1( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12-104 Printed: 07 -18 -2012 PERMIT CONDITIONS Permit No. M12-104 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Readily accessible access to roof mounted equipment is required. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12-104 Printed: 07 -18 -2012 CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: 12 I b 7-,,, %wv6aM A $o- Tenant Name: flit - (Lot"' King Co Assessor's Tax No.: "lam 0 tit O D D 3 Suite Number: Floor: New Tenant: [r Yes ❑..No PROPERTY OWNER Name: Ma. h v — Name: U44e Oti tiv Z- � . City: 564.Aritt State: VA. Zip: co L,61 Address: R. 0 , Do X tki Email: Qte)(60eve.rvvr.r.- ,h‘nu.. cov., City: Got+s ✓k. State: AZ Zip: g 52-61 CONTACT PERSON — person receiving all project communication Name: Ma. h v — Address: -L1 S . keiv,v, Sk . City: 564.Aritt State: VA. Zip: co L,61 Phone: 706,..-?6-3 , ti 4 ‘4 .1?-4:ii. Fax: 7,0E- 3— 24 8 `t Email: Qte)(60eve.rvvr.r.- ,h‘nu.. cov., MECHANICAL CONTRACTOR INFORMATION Company Name: n fry)v-ifivi,-n Address: 1^1/1 S kev411c, 9. City: S State: vA Zip: qigIA Phone: 7/06 _143 ,.. IZLILI. Fax: .7/06 , ?(3 - z- i Contr Reg No.: sU 6.r u r1 S y 12, Exp Date: 1' 6 / i , Tukwila Business License No.: t3V5 06191/9-17 Valuation of project (contractor's bid price): $ 6l 61 36 Describe the scope of work in detail: y,� Fx,UI -r1 o^<. (> c Jt,{'t-YS Lek uh k ck,c Use: Residential: New ❑ Replacement ❑ New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: H:\Applicattons\Forms- Applications On Linet2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater I Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct I Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment jpk )6^ Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: C� Print Name: , BLX Day Telephone: �' ' 7 T 1 ? e7.-4-. 24—r Mailing Address: 727 5 . ie- ') ( 4,g0$ Date: to 1 / (L- H:\Appltcations \Forms - Applications On Lute \2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh City State Zip Page 2 of 2 CiP of Tukwila, s Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: /Avww. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -01990 Initials: JEM Payment Date: 06/26/2012 User ID: 1165 Total Payment: 332.31 Payee: EVERGREEN REFRIGERATION, LLC SET ID: S000001766 SET NAME: EVERGREEN REFRIGERATION SET TRANSACTIONS: Set Member EL12 -0595 M12 -104 TOTAL: Amount 63.00 269.31 63.00 TRANSACTION LIST: Type Method Description Amount Payment Check 005451 332.31 TOTAL: 332.31 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.101.00.0 000.322.102.00.0 000.345.830 63.00 215.45 53.86 TOTAL: 332.31 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G (206) 431 -3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Projefti Typc,o Inspect n: Ake jii Add l 7i-ress: (, (0 . ± �1` " rJ't ` s led: : --� D to u Li6 w /"` Special Instructions: f-�- D e ss' ' 51 ` 7 U Ji Date Wanted�_'2_3 j ? /(ap.m. �! \ ni Requester: Phone No: _740 (— (e71 --5r�Z Approved per applicable codes. Corrections required prior to approval. COMMENTS: (,,to (41p(elre 'fir --•""r Ins ector: i Date n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. MITSUBISHI ELECTRIC COOLING & HEATING f1ir.S�llf1. Split - ductless A/C and Heat Pumps SUBMITTAL DATA: MSZ- GE18NA -8 & MUZ- GE18NA -1 18,000 BTU/H WALL - MOUNTED HEAT -PUMP SYSTEMS Job Name:- Purchaser: FILE COPY Submitted to: System Designation: PeT1 t " Location: Engineer: ❑Reference ❑Approval ❑Construction Schedule No.: IDate: DI -- GENERAL FEATURES • Wall- mounted indoor unit • Standard Hybrid Catechin Prefilter is included with indoor unit • Quiet operation • Choice of fan speeds: Quiet, Low, Medium, High, and Super High Auto fan speed control also included • Hand -held Wireless Remote Controller • Indoor unit powered from outdoor unit using A- Control • Auto restart following a power outage • Base heater is available as an option • Anti - allergy Enzyme Filter • Limited warranty: five years on parts a on the compressor OPTIONAL ACCESSORIES Outdoor Unit ❑ Base Heater (MAC-641BH-U) ❑ Drain Socket Assembly (MAC -811 DS) Indoor Unit ❑ Condensate Pump (230V; SI3100 -23 Controller Options I ❑ Wireless Remote Controller Kit (MH 4 )��yyll' er1 • - 'C•rlt�fl�r•�I� (MRCH1), Wireless Receiver (MIFH1) , @IA V I • N ❑ Setback down to 50 °F when used wi - ❑ Portable Central Controller (MCCH1; for use with Wireless Remote Controller Kit MHK1)* ❑ Outdoor Air Sensor (MOS1; for use with Remote Controller (MRCH1), Wireless Remote Controller Kit (MHK1) and Portable Central Controller (MCCH1)* 'See Submittal for information on each option. ❑ Wall- mounted Wired Controller (PAR -21 MAA; req. MAC -3971 F) ❑ MA Contact Terminal Interface (MAC- 397IF) ❑ M -NET Control Adapter (MAC- 3991F) ❑ Remote Temperature Sensor (M21 -JKO -307) ❑ Lockdown Bracket for Hand -held Controller (RCMKP1 CB) Cooling* Rated Capacity 17,200 Btu /h Minimum Capacity 3 700 Btu /h SEER 19.2 Btu /h/W Total Input 1 640 W Heating at 47 °F" Rated Capacity 21,600 Btu /h Minimum Capacity 3,500 Btu /h HSPF 10.0 Btu /h/W Total Input 1 900 W Heating at 17 °F* Rated Capacity 13,400 Btu /h Rated Total Input 1 450 W Maximum Capacity 17,200 Btu /h Maximum Total Input 2,080 W Rating Conditions (Cooling) - Indoor: 80 °F (27 °C) DB, 67 °F (19°C) WB; Outdoor: 95 °F (35 °C) DB, 75 °F (24 °C) WB. (Heating at47°F)- Indoor: 70°F (21°C) DB, 60°F (16°C) WB; Outdoor:47°F (8°C) DB, 43°F (6°C) WB. (Hearing at 17°F)- Indoor. 70°F (21°C) DB, 60°F (16°C) WB; Outdoor 17°F (-8°C) DB, 15°F ( -9°C) WB. Electrical Requirements Power Supply 208 / 230V, 1- Phase, 60 Hz Breaker Size Indoor Unit MSZ- GE18NA -8 d defRE VIEWS& FOR 0 ERATING RANGE CODE COMPLIANCE' APPROVED JUL 17 2012 15A Voltage Indoor - Outdoor S1 -S2 AC 208 / 230V Indoor - Outdoor S2 -S3 DC 12 -24V Indoor - Remote Controller Wireless © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. Wireless Remote ! Controller Outdoor Unit: MUZ- GE18NA -1 Indoor Intake Air Temp. Outdoor Intake Air Temp. ooling Maximum 90 °F (32 °C) DB, 73 °F (23 °C) WB 115 °F (46 °C) DB Minimum 67 °F (19 °C) DB, 57 °F (14 °C) WB 14 °F ( -10 °C) DB eating Maximum 80 °F (27 °C) DB, 67 °F (19 °C) WB 75 °F (24 °C) DB, 65 °F (18 °C) WB Minimum 70 °F (21 °C) DB, 60 °F (16 °C) WB -4 °F ( -20 °C) DB, -5 °F ( -21 °C) WB door Unit CA 1A an Motor 0 76 FL.A. now (Quiet - Lo - Med - Hi - Super Hi) Cooling 230 - 275 - 339 - 420 - 533 Dry CFM 194 - 240 - 304 - 385 - 498 Wet CFM Heating 230 - 275 - 339 - 431 - 512 Dry CFM Sound Pressure Level (Quiet- Lo - Med - Hi - Super Hi) Cooling 28 - 33 - 38 - 44 - 49 dB(A) Heating 28 - 33 - 38 - 43 - 49 dB(A) DIMENSIONS UNIT INCHES / MM W 31 -7/16 / 799 D 9 -1/8 / 232 H 11 -5/8 / 295 Weight 22 lbs. / 10 kg External Finish Munsell No. 1.0Y 9.2 / 0.2 Field Drainpipe Size O.D. 5/8" / 15.88 mm Outdoor Unit Compressor DC Inverter -driven Twin Rotary MCA 14 A Fan Motor 0.93 F.L.A. Sound Pressure Level Cooling Heating 54 dB(A 56 dB(A) DIMENSIONS INCHES / MM W 33-1/16 / 840 13/330 H 33 -7/16 / 849 Weight 119 lbs. / 54 kg External Finish Munsell No. 3Y 7.8 / 1.1 Refrigerant Type R41 OA Refrigerant Pipe Size O.D. Gas Side 1/2" / 12.7 mm Liquid Side 1/4" / 6.35 mm Max. Refrigerant Pipe Length 100 ft. / 30 m Max. Refrigerant Pipe Height Difference 50 ft. / 15 m Connection Method Jared DIMENSIONS: MSZ - GEI8NA -8 & MUZ- GEI8NA -1 MSZ - GEI8NA -8 2- 5/8 3/4 7/16.1 Oblong hole Installation plate 3-1/8 31 -7/16 30-15/16 1/4 Indoor unit 0 8-7/8 U 1 -15/16 24-3/8 I 5-1/8 I fl Is 2 -3/18 • • • 2 -3/8 a L Unit: inch 7116 •13/16 Oblong hole 8-7/8 3-1/8 @ A 61/8 .}. 6-1 /8 w 13-5/16 i 13-9/16 d, 21 do Vir 2 -1/8 Air in Wall hole 02 -9/18 Installation ate i•I _ T / ,-5/6 � � r Drain hose Air out 4-3/8 P F. a Insulation 01 - 3/8 0.D Liquid line e1/4 19 - 11/16 (Flared connection 01/4) Gas line 03/8 16 - 15/16 (Flared connection: 03/8 (GE98109/12NA), 012 (GE15/18NA)) Drain hose Insulation 01 -1/8 0.D Connected part 05/8 0.D MUZ - GEI8NA -1 Drain 3 holes (01 -5/16) 20 -9/32 1 -9/16 33 -1/16 4-3/8 ■ 13/16 slot 3-3/16 4-25/32 REQUIRED SPACE Open as a rule 20 inch or more if the front and both sides are open 4 inch or more/ 8 inch or more if there are obstacles to both sides Open as a rule 20 inch or more if the back, both sides and top are open Liquid:1 /4(flared) m Gas :1/2(flared) 611/32 �i CERTIFIED,. www.ahrldireotor9.ore Unitary Small HP AHPo Standard 210/240 at**. q■••• wry wan ew Compide rwm%b WWI wide Mt Intertek FORM# MSZ- GE18NA -8 & MUZ- GE18NA -1 - 201008 © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. ENERGY STAR PARTNER mtMITSUBISHI ELECTRIC C O O L I N G & H E A T I N G Live Better 3400 Lawrenceville Suwanee Rd Suwanee, GA 30024 Tele: 678 - 376 -2900 • Fax: 800 - 889 -9904 Toll Free: 800 - 433 -4822 ( #3) www.mehvac.com Specifications are subject to change without notice. ORWA® FILE COPY Permit No. SPECIFICATION SHEET QTR / QTRE SERIES FANS MODELS QTR050F, QTR080, QTR110 QTRE080, QTRE080R, QTRE110 QTRE080 QTRE110 Ultra- quiet, high performance bath fan with a modern - styled grille. FEATURES BLOWER: • Plug -in, permanently lubricated motor - engineered for continuous operation • Dynamically balanced centrifugal blower wheel for quiet, efficient performance • Low RPM for quiet operation • Resilient anti - vibration motor mounts (QTR080 only) HOUSING: • Rugged, 26 gauge, galvanized steel construction • Polymeric, 4" round duct connector with tapered sleeve and no metallic clatter • 7 -5/8" height allows for 2" x 8" (nominal) joist installations • Sturdy, easy mounting directly to joist • Includes hanger bars to position housing anywhere between 16" to 24 " -on- center joists (Models QTRE080 & QTRE110 only) • Includes mounting frame for easy retrofit or replacement of existing fan (QTRE808R only) GRILLE: • Polymeric construction • Innovative design - the result of extensive research with designers and consumers BUILDER PACKS: • Broan Model QTRO5OF - Includes blower and grille only (packed 1 per carton) • Rough -in housing required - order Broan Model QTXR000HF (4 housings per carton) - Includes hanger bars to position housing anywhere between 16" to 24 " -on- center joists (4 sets of hangers per carton) - Two sets of mounting holes for hanger bars allow flush installation with bottom or top of drywall CONTROLS (Purchase separately): • Model 69 L (Ivory) / 69WL (White) - One rocker switch with "on" indicator light • Other controls available from Broan - NuTone U.L. Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit (ceiling mount only). 3 -Year Warranty TYPICAL SPECIFICATION Ceiling Ventilator shall be Broan Model QTR050F (QTR080) (QTR110) (QTRE080) (OTRE080R) (QTRE110). Ceiling Ventilator shall have corrosion resistant galvanized steel housing. It shall be ducted to a roof or wall cap using 4" round ductwork. Blower assembly shall be removable, have a centrifugal -type blower wheel and a permanently lubricated motor designed for continuous operation. Non - metallic damper /duct connector shall be included. Air delivery shall be no less than 50 (80) (110) CFM and sound level no greater than 0.4 (0.8) (1.0) (1.3) (1.5) Sones. All air and sound ratings shall be certified by HVI. Ceiling ventilator shall be Energy Star® qualified and have an energy efficient permanent split capacitor motor (Models QTRE080, QTRE080R & QTRE110 only). Ceiling Ventilator shall be U.L. Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit. 7 /Ila QTR080 QTR110 i 0! Ile/ 2-- / QTRE080 QTRE110 /' Ile QTREO8OR IHIVI CERTIFIED Broan NuTone LLC Hartford, Wisconsin www.broan.com 800 - 558 -1711 /14 ENERGY STAR Models QTRE080, OTREO8OR & QTRE110 only REFe ",IEV'dElTFoOR CODE COMPLIAN APPROVED JUL 17 2012 Tukwila CE City of BUILDING DIVISION REMARKS Project CITY W iiA JUN 262012 PERMIT CENTER Location Architect A I " / r Engineer Contractor Submitted by Date 90K 99043401G PERFORMANCE RATINGS QTTR / QTRE SERIES FANS HVI PERFORMANCE Model QTRO5OF QTR080 Static Pressure (Ps) 0.10 CFM 50 Sones 0.4 0.25 0.10 0.25 28 80 66 1.0 Fan Watts TR110 0.10 0.25 110 98 1.5 QTRE080 QTREO8OR 0.10 80 0.8 0.25 OTRE110 2100 0.10 55 110 HVI CERTIFIED AMPS Model QTRO5OF - QTR080 OTR110 QTRE080 QTREO8OR QTRE110 0.25 89 1.3 28.2 36.3 HVI -2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off- the -shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in a state-of-the-art test laboratory. Sones are a measure of humanly- perceived loudness, based on laboratory measurements. Amps 0.2 0.7 0.3 0.3 0.3 ENERGY STAR Models QTRE080, QTREO8OR & QTRE110 only WEIGHT Model QTRO5OF QTR080 QTR110 QTR E080 QTREO8OR OTRE110 AIR FLOW PERFORMANCE MODEL QTRO5OF 0.5 0.4 010.3 3 0.2 a 0.1 0.0 0 Shipping Weight 6.6 lbs. 12.4 lbs. 12.4 lbs. 12.4 lbs. 13.0 lbs 10 20 30 40 Airflow (cfm) BRM 50 60 70 Broan - NuTone LLC Hartford, Wisconsin AIR FLOW PERFORMANCE MODEL QTR080 0.9 0.8 0.7 • 0.6 0.5 0.4 a (1 0.3 0.2 0.1 0.0 0.9 0.8 0.7 • 0.6 O 10 20 30 40 50 60 70 Airflow (cfrn) -+MODEL QTR110 80 90 100 3 0.5 v 0.4 a 0.3 0.2 0.1 0.0 O 10 20 30 40 50 60 70 80 90 100 110 Airflow (cfm) MODELS QTRE080 & QTREO8OR 0.6 0.5 0.4 3 0.3 In a 0.2 0.1 0.0 0 120 0.7 0.6 0.5 0.4 •c .,0.3 a 0.2 0.1 0.0 0 10 10 20 30 40 50 60 70 Airflow (cfm) MODEL QTRE110 80 90 100 www.broan.com NNN\\ 20 30 40 50 60 70 80 Airflow (cfm) 800 - 558 -1711 90 100 110 120 130 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary MECH -SUM ' 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address 12610 Interurban Avenue South Date 6/25/2012 Tukwila, WA 98168 For Building Dept. Use Applicant Name: Evergreen Refrigeration Applicant Address: 727 S. Kenyon St. Seattle, WA 98108 Applicant Phone: 206- 763 - 1744x247 �ect Briefly describe system type Description mechanical and features. Plans Installation of one (1) ductless split system unit and one fan. REV jIEvVEo ODE COMPLIANCE APPROVED Drawings must contain notes requireing compliance with corn ssioning requirements t�a: 'f (1) exhaust FOR - Section 1, 6 4 Includes Compliance Option Simple System Q Complex System Q System ,'Analyst�JL 1 7 211 (See Decision Flowchart (over) for qualifications. Use separa MECH -SUM for simple & complex Equipment Schedules The following information is required to be incorporated with t e mec I s hedule on the plans. For projects without plans, fill in the required infor I ��. ING DIV,Si ti Cooling Equipment Schedule .- Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N AB 1' CO -1 Mitsubishi MSZ- G818NA -8, MOZ- GR18NA -1 17200 19 . 2 1433.10 N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu /h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N A8 1' CU -1 Mitsubishi MSZ-GE18NA-8, MUZ- GE18NA -1 21600 21600 21600 10 N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 CFM $p' HP /BHP Flow Controls Location of Service EP -1 Eroan QTR110 90 0.20" 0.10 cv c 1 T JUN 2 6 2012 WOW PERMIT 11f available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section IuM- 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary (back) MECH -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 System Description See Section 1421 for full description of p Simple System qualifications. All Systems: .✓ No humidification? ✓ No Reheat? If Heating/Cooling or Cooling Only: 9 y: ✓ Constant vol? ✓ Split system? ✓ < =84,000 Btuh? ❑ Economizer included? ❑ Air rnnlarl? ❑ Parkannri sys? ❑c =115.nnn Rtiih? ❑ Coolina Can < =15 Btuh /ft2? ❑ Heating Cap. > 0 & < =10 Btuh/ft2? If Heating Only: ❑ <1 nnn rfm9 ❑ <30% outside air? ❑ Heating Cap. < =10 Btuh/ft2? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. CSTART ft2, or ft2 Yes Yes Heating/Cooling or Cooling Only No Heating Only Reference Section 1421 Yes Yes Yes eatin Cap <= 10 Yes - tuh/ alifies Economizer Exception ion 1 Yes • Simple System Allowed (section 1420) Yes • Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist MECH -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address 12610 Interurban Avenue South !Date 6/25/2012 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment Performance Yee 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Ml N.A. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss N.A. 1411.1 Air - cooled chiller Provide total air and water chiller capacity N.A. 1411.2.1 Water - cooled chiller Full -load and NPLV values adjusted for any non - standard conditions N.A. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule N.A. 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls N.A. 1412.1 Temperature zones Indicate locations on plans Yes 1412.2 Deadband control Indicate 5 degree deadband minimum Ml N.A. 1412.3 Humidity control Indicate humidistat Yee 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback M1 N.A. 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage N.A. 1412.4.2 Optimum Start Indicate optimum start controls N.A. 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule N.A. 1412.6 Combustion heating Indicate modulating or staged control Yes 1412.7 Balancing Indicate balancing features on plans Ml N.A. 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas N.A. 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. N.A. 1422 Thermostat interlock Indicate thermostat interlock on plans N.A. 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers N.A. 1412.1 Single zone systems Indicate multiple cooling stage control capability. Yee 1413.1 Air Econo Operation Indicate 100% capability on schedule Ml N.A. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb N.A. 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. N.A. 1413.3 Integrated operation Indicate capability for partial cooling N.A. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems N.A. 1414.1 Duct sealing Indicate duct design pressures, sealing, and testing requirements N.A. 1414.1.2 Low press. duct test Indicate applicable low pressure duct systems shall be leak tested N.A. 1414.1.3 High press. duct test Indicate high pressure duct systems shall be leak tested, and identify the location of this ductwork on plans N.A. 1414.2 Duct insulation Indicate R -value of insulation on duct 1415 Piping Systems N.A. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements Yes 1416.3.2 System Balancing Indicate air and water system balancing requirements Ml Yee 1416.3.3 Functional Testing Provide sequence of operations and test procedures. Ml Yes 1416.3.4 Documentation Indicate O &M manuals, record drawings, staff training M1 Yee 1416.3.5 Comm. Report Indicate requirements for final commissioning report M1 N.A. 1416.4 Compliance Chklist Submit to building official upon substantial completion. Yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential 'Mechanical Permit Plans Checklist Continued MECH -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address 12610 Interurban Avenue South 'Date 6/25/2012 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. N.A. 1441 Elec. water heater Indicate R -10 insulation under tank N.A. 1442 Shut -off controls Indicate automatic shut -off of circulators or heat trace N.A. 1443 Pipe Insulation Indicate R -value of insulation on piping N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. 1460 Heated Pools N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R -12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction COLD STORAGE (Sections 1460 -1465) 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Sections 1401 -1424 or 1440 -1465 , provide explanation: • ., • *Evergreen Eve,tlreen • Refrigeration HVAC 3 HVAC & CONTROLS DESIGN INSTALLATION SERVICE CORRECTION LETTER #1 RESPONSE DATED 07/10/12 To: City of Tukwila Building Department Attn: Dave Larson Permit Number: M12-104 Project Name: Hill -Rom 1. Please provide a floor plan of the space to show where the new equipment will be installed. Response: A floor plan has now been provided on a new page, A0.1. 2. Is the condenser outside on the ground or on the roof? Show location on relative plan. Response: The condenser is located on the roof. It has now been labeled as such on page Ml and the location of the space relative to the rest of the building has been provided on a new page, A0.1. 3. Label the room where the ductless split will be installed. Does the room have exterior insulated walls? Is the roof /ceiling insulated? Is this a new cooling load or replacing existing cooling load? Response: The room where the ductless split will be installed has now been labeled as "Files/Data Room" on page Ml. The room has exterior insulated walls, the roof is insulated, and this is a new cooling load. CORRECTION 727 SOUTH KENYON ST. - SEATTLE, WA. 98108 (206) 763 -1744 - FAX (206) 763 -2389 t1L2b 1DM RECEIVED JUL 10 2012 PERMIT CENTER Evergreen Refrigeration, Inc. • •07/10/2012 (Continued) If you have any questions or comments, please contact me at the information located below. Sincerely, Alex Burkhart Evergreen Refrigeration, LLC 727 S. Kenyon St. Seattle, WA 98108 Desk: 206 - 763 -1744 ext. 247 Fax: 206 - 763 -2389 alexb@evergreenhvac.com 727 SOUTH KENYON ST. - SEATTLE, WA. 98108 (206) 763 -1744 - FAX (206) 763 -2389 July 5, 2012 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Alex Burkhart Evergreen Refrigeration 727 S Kenyon St Seattle, WA 98108 RE: Correction Letter #1 Mechanical Permit Application Number M12 -104 Hill -Rom —12610 Interurban Av S Dear Mr. Burkhart, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. Sincerely, D R•L Bill Rambo Permit Technician encl File No. M12 -104 W:\Pennit Center \Correction Letters \2012 \M12 -104 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: July 3, 2012 Project Name: Hill -Rom Permit # M12 -104 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Please provide a floor plan of the space to show were the new equipment will be installed. 2. Is the condenser outside on the ground or on the roof? Show location on relative plan. 3. Label the room were the ductless split will be installed. Does this room have exterior insulated walls? Is the roof /ceiling insulated? Is this new cooling load or replacing existing cooling load? Should there be questions concerning the above information please contact the Building Division at 206- 431 -3670. ittT u0 CAP IP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -104 PROJECT NAME: HILL -ROM SITE ADDRESS: 12610 INTERURBAN AV S Original Plan Submittal X Response-to,Correction Letter # 1 DATE: 07 -10 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: ci BGmling ivi n Public Works n Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 07 -12 -12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S 1 TIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: DUE DATE: 08 -09 -12 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 *ERMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -104 DATE: 06/26/12 PROJECT NAME: HILL -ROM SITE ADDRESS: 12610 INTERURBAN AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 1-)L- hAol Vitt- /11" Building Division Fire Prevention Planning Division Public Works Structural Permit Coordinator n n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 06/28/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required Ti No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/26/12 Approved Approved with Conditions Ti Not Approved (attach comments) M Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only }^ CORRECTION LETTER MAILED: Departments issued corrections: Bldg IR' Fire ❑ Ping ❑ PW ❑ Staff Initials: m'( • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tuki'ila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1/ IC) / I2 Plan Check/Permit Number: M12-104 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Hill -Rom Project Address: 12610 Interurban Av S Contact Person: AID � Phone Number: 2M6 " 7C;'5 7 4'I act.v17 Summary of Revision: Pc-r &ay- evi-;ts -, L Vii- 914),..- () .. Y►Ns Lxe.„, vwr 4 (A-c. cf- 11.,5 „ v v (M Pro _. l� uw+' +&c . (Dv ;34./6 (,mrruf1- Lei I145 irnst RECEIVED CITY OF TUKWILi f IUL 11.0 2012 Sheet Number(s): M 1 IA 0.1- PERMIT CEldTEF4 "Cloud" or highlight all areas of revision including date of revii io, Received at the City of Tukwila Permit Center by: entered in Permits Plus on l I V 12. \applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople P.ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name EVERGREEN REFRIGERATION LLC UBI No. 602512953 Phone 2067631744 Status Active Address 727 S Kenyon St License No. EVERGRL954R2 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 1/6/2006 State WA Expiration Date 1/6/2014 Zip 98108 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EVERGHH910J0 EVERGREEN HOME HEATING & ENGY Construction Contractor General Unused 4/20/2009 4/20/2013 Active EVERGI'201D7 EVERGREEN REFRIGERATION INC Construction Contractor General Unused 3/27/1980 7/31/2006 Re Licensed Business Owner Information Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC Partner /Member 12/22/2005 Bond Amount PATTON, DAVID Partner /Member 01 /06/2006 WA15097 PATTON, RODGER Partner /Member 01 /06/2006 PATTON, MATTHEW Partner /Member 01 /06/2006 TRAVELERS CAS a SURETY CO Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Merchants Bonding Co (Mutual) WA15097 01/01/2012 Until Cancelled $12,000.00 12/15 /2011 1 TRAVELERS CAS a SURETY CO 104667361 01/01/2006 Until Cancelled $12,000.0001 /03 /2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 AMERICAN FIRE AND CASUALTY COM BAW54192293 07/31/2010 07/31/2012 $1,000,000.00 07/27/2011 2 Continental Western Ins Co CWP2640663 07/31/2006 07/31/2010 $1,000,000.0003 /23/2009 1 ALASKA NATIONAL INSURANCE CO 05GLS31381 07/31/2005 07/31/2006 $1,000,000.0001 /03/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni /bbip /Print.aspx 07/18/2012 MARK MANF. MODEL EXHAUST FAN SCHEDULE CFM S. P. EF 1 BROAN QTR 110 90 0.2" VOLTS PHASE Hp /A NOTES 115 71 W. LOCATED ON CEILING COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS . RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE . PER WA ENERGY CODE (WSEC) SECTION 1416.3.4.2 AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.3.4.1 ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14(516.3.2.1. • FOR C SECT ONS 421) H IAC CONTROL SPACES, SIMPLE BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.3.3. FOR ALL OTHER SYSTEMS: HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.3.3. NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.3.3; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION 1416.3.4.1 AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.4 GENERAL, NOTES DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION 1 0 OBTAIN OUTSIDE DIMENSION, ADD 4 "TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND. NUMBER IS THE HEIGHT. . • , 1.3. MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603,10. 1.7 ` ATTACH DIFFUSERS AND GRILLES TO T -BAR ARID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES.` 2.2 INSULATE REFRIGERANT 8 CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. MJr PUBLISFIGU. ALL KJUKIS Kt. tKVGU. IF1t • DRAVING AND SPECIFICATIONS, IDEAS, DESIGNS • AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION DEC. NO PART THEREOF SHALL DE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE. PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC - ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. W GENERAL CONTRACTOR • 3.1 GENERAL CONTRACTOR TO PROVIDE AND GUT OPENINGS FOR ALL ROOFTOP CEILING FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRS PROOF LINING PER IMC & IBC. GENERAL CONTRACTOR TO VERIFY PENETFATION LOCATION AND DIMENSIONS WIFRE AG L. GENERTH AERL L CONTRACTOR BEO FRAMING TO PROVIDE OPENINGS ALL DEMOLITION, PATCHING, AND PAINTING VICINITY MAP SCALE: NONE MARK MANF. SPLIT SYSTEM EQUIPMENT SCHEDULE COOLING HEATING CAPACITY ELECTRICAL MODEL TOTAL SEER EER RATED MIN VOLTS PHASE M.C.A. WEIGHT NOTES AH -1 CU -1 MITSUBISHI MITSUBISHI NISZ- GE18NA -8. klUZ -GE 18NA -1 BTUH BTUH BTUH (V) '208-230 10 (A) 1 LBS 22 17,200 19.2 21,600 3,500 208 -230 10 14 119 LOCATED ON ROOF 3.2 3.3 3.4 3.5 AS REQUIRED FOR MECHANICAL WORK: GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK:. GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK.: 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED .BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. • 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OFT OAR CEILING AS FR LA. 3.9 GENERAL REQUIRED CONTRACTOR OHVAC TI PROTECT TION ALL (»ENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. . ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WRING, CONDUIT WILL BE PROVIDED BY . 4.2 ELECTRICAL CONTRACTOR ELECTRICAL CONTRACTOR TO PROVIDE ALL, ELECTRICAL CONNECTIONS, DISCONNECTS, AND STA CH __ _ 4.3 ELECTRICAL CONTRACTOR TO VERIFY. EQUIPMENT SIZES LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. . MECHANICAL EQUIPMENT.:, ASA ON ROOF 1013.5 Mechanical Equipment.. Guards shall be provided where appliances, equipment, fans, roof hatch opening or other components that require service are located within 10- feet of a roof edge or open side of a. walking surface and such edge or open side is located more than 30- inches above the floor, roof or grade below. The guard shall be constructed so as to prevent the passage of a 21- inch - diameter sphere. The guard shall extend not less than 30- inches beyond each end of such appliances, equipment, fan or component. 1013.6 Roof Access. Guards shall be provide where the roof hatch opening is located within. 10 -feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30- inches above the floor, roof or grade below. The guard shall be constructed so as to prevent the passage of a 21- inchdiameter sphere. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5 °F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. (n Z o - Q: ••.. Fc CI CD J L Z •. Q. Q . Z . Z 'S E O . h= 0 to a 0 V) LL1.. D 1- UJ >. , •LQ J o C9 co c pa. O Z v) Q-' . < U < on El 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH P'--._ OF --- ..HANK. EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 1 Q FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT or, INTAKE, IMC 401.4.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH CONTROL FLOOR FOR IS TO EACH BE CONSI ZONE DERED A SEPARATE ZONE. VERIFY .. AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS AND RELIEF OUTLETS SERVING . AUTOMATICALLY SPACES SHALL BE EQUI OF) WITH DAMPERS WHICH CLOSE PER WSEC .. .1. OR UPON POWER FAILURE, 6.3 AIR ECONOSECMIZERS 14 WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE r1T 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC ShIUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR OOOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. . WA2004 $1 SYMBOL DESCRIPTION FILES /DATA. ROOM RECTANGULAR DUCT REVISIONS 07/10/12 CITY COMMENTS ■ FIRE DAMPER FILE COPY SEPARATE PERMIT REQUIRED FOR: DM Et Electrical Plumbing Gas Piping Plan review Approval of c onstn the violation of any of approved Field does not authodze ordinance. Receipt 'edged: CEILINra RADIATION DAMPER SMOKE. DETECTOR T HER 1110STAT SENSOR DRAWING DATE: City of Tukwila BUILDING � DIVISION 06/22./12. 6 " UP v o NATURAL GAS LINES CEILING DIFFUSER (SUPPLY) City Of htkvilla BUILDING DIVISION JOB . NO.: REVISIONS o nrk withoute prior made approval of of Tukwila Building Division. NOTE: will t e submittal Revisions include additional plan review fees. HVAC FLOOR PLAN B.O.J. 12' 2' SCALE : 1/4" = 1' -0 ". INLINIr.. FAN RECEIVED. 412130 DWG. FILE: 412130M1 PROPELLER FAN DUCT PITTING DATUM UNIT TAG DUCT RISER SHEETS T H E RONHOVDE ARCHITECTS L L C 14100 INTERURBAN AVE SOUTH SUITE 13E5 TUKWILA, WASHINGTON 98168 (206) 854 -5500 I FAX (206) 854 -5501 ronhovdeor~ch(tects.com \-.„4,3744 REGISTERED ARCHITECT TOR -JAN RONHOVDE STATE OF WASHINGTON 10 5 -22 -12 PERMIT SUBMITTAL NO DATE DESCRIPTION SHEET CONTENTS: . OVERALL BUILDING FLOOR PLAN