Loading...
HomeMy WebLinkAboutPermit M12-109 - MEASUREMENT SYSTEMS INTERNATIONALThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M12-109 Measurement Systems International 14240 Interurban Avenue South RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION F,age # Code Exemption � � �� Brief Explsnatoty Description, Statute /Rule The Privacy Act of 1974 evinces Congress' intent that Personal Information — social security numbers are a private concern. As such, individuals' social security numbers are Social Security Numbers redacted to protect those individuals' privacy pursuant 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. to 5 U.S.C. sec. 552(a), and are also exempt from 552(a); RCW 552(a); RCW disclosure under section 42.56.070(1) of the 42.56.070(1) 42.56.070(1) Washington State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card Personal Information — numbers, electronic check numbers, credit expiration 17 DR2 Financial Information — dates, or bank or other financial account numbers, RCW RCW 42.56.230(4 5) which are exempt from disclosure pursuant to RCW 42.56.230(5) 42.56.230(5), except when disclosure is expressly required by or governed by other law. MEASUREMENT SYSTEMS INTERNATIONAL 14240 INTERURBAN AV S SUITE 200 M12 -109 City oikukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 3365901881 Address: 14240 INTERURBAN AV S TUKW Project Name: MEASUREMENT SYSTEMS INTERNATIONAL Permit Number: M12 -109 Issue Date: 07/23/2012 Permit Expires On: 01/19/2013 Owner: Name: BELLTOWN INVESTMENT PARTNER Address: 2505 2ND AVE #520 , SEATTLE WA 98121 Contact Person: Name: PAUL GOTO Address: 3132 NE 133 ST , SEATTLE WA 98125 Email: PAUL.GOTO @PSRMECHANICAL.COM Contractor: Name: PSR -HVAC & MECHANICAL SERVICES Address: PO BOX 27073 , SEATTLE WA 98165 Contractor License No: PSRHVMS922NJ Phone: 206 367 -2500 Phone: 206 - 367 -2500 Expiration Date: 04/21/2014 DESCRIPTION OF WORK: SUITE 200: INSTALL (1) NEW DUCTLESS SPLIT A/C ONLY SYSTEM FOR NEW SERVER ROOM Value of Mechanical: $4,206.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied Fees Collected: $244.88 International Mechanical Code Edition: 2009 Date: amin d this permit and know the same to be true and correct. All provisions of law and ordinances vith, hether specified herein or not. The granting of this permit does not pre s m to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -109 Printed: 07 -23 -2012 PERMIT CONDITIONS Permit No. M12 -109 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -109 Printed: 07 -23 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:ilwww.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: 01 77 0I ?213. M ()Pt Date Application. Expires: (For office; use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** King Co Assessor's Tax No.: 33 6.5 1O — lg'$1 Site Address: 114240 In -et-a ain) Avg, 5. Tenant Name: IAONSV17-6mewr SySttfAS Itvtatt4mot,Jert._ Suite Number: 200 New Tenant: PROPERTY OWNER Name: ?Aix. 601.-0 Name: getitbtal inv+GTwieVIr PAnryVt 22f1 Address: 2555 24/v 6- 0520 Email: rAoL . eiCAp a 'PERM FCCuA'Y►108L , coo City:zE State: l Zip: a$LZ) CONTACT PERSON. - person receiving all project communication Name: ?Aix. 601.-0 Address: 3132 146-133¢9 p!' City: e State: ev Zip: art Phone:) 34 7_ Z,SD..z, Fax: (2,0 368'% eigo Email: rAoL . eiCAp a 'PERM FCCuA'Y►108L , coo Floor: 2 ❑ Yes [X. No MECHANICAL CONTRACTOR INFORMAT ION Company Name: r5(L N•ECAnA'1V Kest.. Address: 3'137_ 146 I3'142A ST City: 3 le State: Zip: agtZ$ Phone:( � X67- v Fax: ) 368' -68 Contr Reg No.: aitkivIvt,012,E4 Jr xp Date / 30! ty Tukwila Business License No.: als --Oct934gg Valuation of project (contractor's bid price): $ 411206 Describe the scope of work in detail: tn9i i (1) "641 Dttcxtess �fs 'td SPLrr Pr/ avtk ;ppt-Grn (F„IL Plena! S .w rum.) - Use: Residential: New Commercial: New Fuel Type: Electric E g Gas Replacement Replacement Other: II: \Appl icaliois'.Forns•Appl icat ions On Linc12011 Applicel tuns Nle..haniwl Permit Appl di tun Res iseJ 3 -0 -1 Ldoc. Revised: August 2011 bh Page 1 or2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall /floor mounted heater Appliance vent Repair or addition to heat/refrig /cooling system Air handling unit / <10,000 cfm 1 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: -r /t3 i/Z- Print Name: PAL Gen Day Telephone:r(2O) SG 7- ZaTO Mailing Address: '1'2. Aft !'332Q Sr" FI: \Applicaiions \Porn Applic.tions On Line \2011 Appli..aioit.;\Tkchaui.al Permit Appli..aliun Res is J S -9 -I 1.Jo.x Res'ised. August 2011 bh Setrine t.et QB`t zS City State Zip Page 2 of 2 C City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.ov RECEIPT Parcel No.: 3365901881 Permit Number: M12 -109 Address: 14240 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 07/13/2012 Applicant: MEASUREMENT SYSTEMS INTERNATIONAL Issue Date: Receipt No.: R12 -02122 Initials: JEM User ID: 1165 Payment Amount: $244.88 Payment Date: 07/13/2012 01:00 PM Balance: $0.00 Payee: PSR HVAC & MECHANICAL SERVICES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 011769 244.88 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 195.90 000.345.830 48.98 Total: $244.88 doc: Receiot -06 Printed: 07 -13 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 F (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: P a rIJ 18 tit eik \ S tc (e4f Type of Insp ection: LA JG� u G - i Jt Addr4 7.4 a :F_Are u tw -A.ate Cal - /4. f,r 6C/ ' %9 V Special Instructions: •ti �-- S � Date Wanted: _ a.m. 1 Requester: k. (� _ Approved per applicable codes. Corrections required prior to approval. l� COMMENTS: "TarkpprbJ c,ei ,31 due,c),\ i-i- /Ar.)k,_ 4 . r ‘e.,k _ -.,/i ` „4.- 1 _ a .... 1 r Inspec or: Date: 2 I I REINSPECTION FEE REQUIRED. rior to next inspection, fee must be paid at 6300 Southcenter Blvd.; Suite 100..Catl to schedule reinspection. 7 Air System Sizing Summary for Ductless Split Project Name: Fairway Center Ductless Split Prepared by: PSR 07/13/2012 10:34AM, Air System Information Air System Name* Ductless Split Air System Type. Single Zone CAV FILE COPY Number of zones{ . 1 Floor Area' �'Ci!..p-, No. 1540 sgft Location. Seattle IAP, m as g P'- Sizing Calculation Information Calculation Months. Jan to Dec Calculation method. Transfer Function Method Central Cooling Coil Sizing Data Total coil load. 1.9 Tons Load occurs at Jun 1800 Total coil Toad. 22.3 MBH OA DB / WB: 80.2/63.7 F Sensible coil load. 22.3 MBH Entering DB / WB: 72.7/72.7 F Coil airflow 1500 CFM Leaving DB / WB: 58.7/58.7 F Sensible heat ratio: 1.000 Coil ADP. 57.1 F Area per unit Toad* 82.8 sqft/Ton Bypass Factor' 0.100 Load per unit area: 144.9 BTU /(hr -sqft) Resulting RH• 0 % Design supply temp. 58.0 F Supply Fan Sizing Data Actual max airflow: 1500 CFM Fan motor BHP. 0.00 BHP Standard airflow:. 1476 CFM Fan motor kW. 0.00 kW Actual max airflow per unit area 9.74 CFM /sqft Fan static. 0.00 in wg Outdoor Ventilation Air Data Design airflow:.. 0 CFM Airflow per person. 0.00 CFM /person Airflow per unit floor area 0.00 CFM /sqft Space Sizing Data Space Name Maximum Cooling Sensible MBH Design Airflow. °'CFM Time of Peak Load '. Maximum =- Heating Load MBH Space Floor Area sqft Space CFM/sqft Server Room 22.3 1500 Jun 1800 0.7 154.0 9.74 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 0 2012 City of Tukwila BUILDING DIVISION R CEIED Crrf OF Tt V IEALA JUL 1 S 7012 PERMIT CENTER Block Load 4.15 AM9--- Page 1 of 3 System Design Load Summary for Ductless Split Project Name: Fairway Center Ductless Split Prepared by: PSR 07/13/2012 10:34AM Block Load 4.15 Page 2 of 3 DESIGN COOLING DESIGN HEATING Jun 1800 OA DB / WB 80.2 F / 63.7 F Design Heating Day OADB1WB23F/192F Zone Loads based on TFM ., Details Sensible BTU/hr Latent BTU /hr Details Sensible BTU/hr Latent BTU /hr Window and Skylight Solar Loads 0 sqft 0 - O'sgft - - Wall Transmission 0 sqft 0 - 0 sqft 0 - Roof Transmission 154 sqft 584 - 154 sqft 659 - Window Transmission 0 sqft 0 - 0 sqft 0 - Skylight Transmission 0 sqft 0 - 0 sqft 0 - Door Loads 0 sqft 0 - 0 sqft 0 - Floor Transmission 0 sqft 0 - 0 sqft 0 - Partitions/Ceilings 0 sqft 0 - 0 sqft 0 - Overhead Lighting 200 W 683 - 0 W 0 - Electric Equipment 308 W 1051 - 0 W 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 20000 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 »Total Zone Loads - 22317 0 - 659 0' Thermostat and Pulldown Adjustment - -7 0 - -585 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 1500 CFM 0 - 1500 CFM 0 - » Total System Loads ' 22311 0 - 73 0 Central Cooling Coil - 22311 0 - 0 0 Total Coil Loads' - . - • 22311 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are c g loads Block Load 4.15 Page 2 of 3 "'PERMIT COORD COOP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -109 DATE: 07/13/12 PROJECT NAME: MEASUREMENT SYSTEMS INTERNATIONAL SITE ADDRESS: 14240 INTERURBAN AV S, STE 200 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: �' 12 bit\ 1/Bai ing- Division Fire ' Preve�nti/on I� Public Works Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 07/17/12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route lgtj REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/14/12 Approved Approved with Conditions Jf Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople Pf ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name PSR -HVAC 8 MECHANICAL SERVICES UBI No. 602811195 Phone 2063672500 Status Active Address Po Box 27073 License No. PSRHVMS924JT Suite /Apt. License Type Construction Contractor City Seattle Effective Date 4/30/2008 State WA Expiration Date 4/30/2014 Zip 98165 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status PUGETI`261CG PUGET SOUND REFRIGERATION INC Construction Contractor Air Conditioning Commercial /Industrial /Refrig2 /7/1974 2/1/1984 Archived PUGETSR169CB PUGET SOUND REFRIGERATION INC Construction Contractor General Unused 2/2/1984 12/31/2008 Inactive PSR " "936JP P S R Construction Contractor General Unused 4/17/200712/31 /2008 Re- Licensed Business Owner Information Name Role Effective Date Expiration Date O'MALLEY, JAMES J Member 04/30/2008 Amount HOGERTY, REAGAN P Member 04/30/2008 GL0488649702 O'DONNELL,STEPHEN 0 04/01/2013 04/30/2008 04/12/2012 RIST, STEVEN L 04/05/2012 04/30/2008 04/12/2012 Bond Information No records found for the previous 6 year period Assignment of Savings Information Page 1 of 2 Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 4/30/2008 Until Released Bond $12,000.00 4/30/2008 Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 Zurich American Ins Co GL0488649702 04/01/2012 04/01/2013 $1,000,000.00 04/05/2012 5 Zurich American Ins Co GL0488649701 04/01/2011 04/01/2012 $1,000,000.00 04/04/2011 4 ZURICH AMERICAN INS CO GL0488649700 04/01/2010 04/01/2011 $1,000,000.00 04/05/2010 3 HARTFORD CAS INS CO 37UUNN03345 04/01/2009 04/01/2010 $1,000,000.00 03/31/2009 2 HARTFORD FIRE INS CO 37UUNN03345 06/01/2008 06/01/2009 $1,000,000.0006 /06/2008 https: // fortress .wa.gov /lni /bbip /Print.aspx 07/23/2012 Foster Golf #.intrs 5 144th St arfire Sports Cnrnj)lex Farrl -y Fun Center R Bullvrink"e's Restaurant }Pacifir1 '64Fi oirteer Meld Southcenter 1:t1 California SITE VIC\ITY NTS SITE INFO ADDRESS: OWNER: PARCEL /TAX # LEGAL: 14240 INTERURBAN AVE. S. TUKWILA, WA 98168 BELLTOWN INVESTMENT PARTNER 3365901881 HILLMANS SEATTLE GARDEN TRS POR OF LOT 1 & ALL OF LOTS 2 THRU 7 & POR ADJ IN SE 1/4 OF SECTION 14 -23 -04 DAF - BEG SE COR OF SAID LOT 7 TH NLY ALG ELY LN 315 FT TO LFT BANK OF DUWAMISH RIVER AS ORIGINALLY PLATTED TH CONTG ON NLY PROD OF SD ELY 220 FT M/L TO LFT BANK AS EXISTED UNDER SUPERIOR COURT CAUSE NO 81 -2- 05910 -4 TH WLY ALG SD BANK TO AN INTSN WITH NELY PROD OF SELY LN OF NWLY 72 FT OF SD LOT 1 TH SWLY ALG SD LN PROD 200 FT M/L TO LFT BANK OF DUWAMISH RIVER AS PLATTED IN ORIGINAL PLAT TH CONTG IN SWLY DIRECTION ALG SELY LN OF NWLY 72 FT OF SD LOT 1 DISTANCE OF 55 FT M/L TO SWLY LN OF SD LOT 1 TH SELY ALG SD LN TO INTSN WITH N MGN OF S 143RD ST FIRST AVE TH ELY ALG SD MGN TO TPOB -TGW POR FOSTER JOSEPH DC #39 BEING POR OF ABANDONED PUGET.SOUND ELECTRIC RR R/W IN THE SW 1/4 OF SE 1/4 OF SD SEC 14 SD RR R/W BOUNDED ON NE BY MAULE AVE ON SW BY A LN 20 FT NE OF & PLT NELY MGN OF SR 181 UNDER REC #8905231113 ON THE SEBYR /W #5 &ON THE NW BY R/W #6 BOTH R/W DEFINED IN QCD AUD FILE # 6557639 - TGW VAC MAULE AVE ADJ TGW POR VAC ST ADJ Y PLA SCALE NOTE: \NJ 2009 WASHI \CTON STATE E \ERGY CODE \OTES GENERAL NOTES 1411.1: EQUIPMENT SHALL HAVE A MINIMUM PERFORMANCE AT THE SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES SHOWN IN TABLES 14 -1A THROUGH 14 -1G. 1411.4: PACKAGED ELECTRICAL EQUIPMENT PROVIDING BOTH HEATING AND COOLING WITH A TOTAL COOLING CAPACITY GREATER THAN 20,000 BTU /H SHALL BE A HEAT PUMP. 1412.1: EACH SYSTEM SHALL BE PROVIDED WITH AT LEAST ONE TEMPERATURE CONTROL DEVICE. EACH ZONE SHALL BE CONTROLLED BY INDIVIDUAL THERMOSTATIC CONTROL RESPONDING TO TEMPERATURE WITHIN THE ZONE. AT A MINIMUM, EACH FLOOR OF A BUILDING SHALL BE CONSIDERED AS A SEPARATE ZONE. 1412.4: HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF ACCOMPLISHING A REDUCTION IN OF ENERGY USE THROUGH CONTROL SETBACK OR EQUIPMENT SHUTDOWN DURING PERIODS OF NON -USE OR ALTERNATE USE OF THE SPACES SERVED BY THE SYSTEM. 1412.4.1: OUTSIDE AIR INTAKES, EXHAUST OUTLETS AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH MOTORIZED DAMPERS WHICH CLOSE AUTOMATTICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE. STAIR SHAFT AND ELEVATOR SHAFT SMOKE RELIEF DAMPERS SHALL REMAIN CLOSED UNTIL ACTIVATED BY SMOKE DETECTION SYSTEM. DAMPERS INSTALLED TO COMPLY WITH THIS SECTION, INCLUDING DAMPER INTEGRAL TO HVAC EQUIPMENT, SHALL HAVE A MAXIMUM LEAKAGE REATE WHEN TESTED IN ACCORDANCE WITH AMCA STANDARD 500 OF: A. MOTORIZED DAMPERS: 10 CFM /SQ. FT. OF DAMPER AREA AT 1.0 IN. W.G. B. NONMOTORIZED DAMPERS: 20 CFM/ SQ. FT. OF DAMPER AREA AT 1.0 INCH W.G., EXCEPT THAT FOR NONMOTORIZED DAMPER SMALLER THAN 24 INCHES IN EITHER DIMENSION: 40 CFM/ SQ.FT. OF DAMPER AREA AT 1.0 INCH W.G. 1412.4.1.1: DAMPERS FOR OUTDOOR AIR SUPPLY AND EXHAUST SHALL AUTOMATICALLY SHUT WHEN THE SYSTEM IS NOT IN USE OR DURING BUILDING WARM -UP COOLDOWN AND SETBACK. 1412.5: UNITARY AIR COOLED HEAT PUMPS SHALL INCLUDE MICROPROCESSOR CONTROLS THAT MINIMIZE SUPPLEMENTAL HEAT USAGE DURING START -UP, SET -UP AND DEFROST CONDITIONS. 1412.7: EACH AIR SUPPLY OUTLET OR AIR OR WATER TERMINAL DEVICE SHALL HAVE MEANS FOR BALANCING, INCLUDING BUT NOT LIMITED T0, DAMPERS, TEMPERATURE AND PRESSURE TEST CONNECTIONS AND BALANCING VALVES. 1413.1: AIR ECONOMIZERS SHALL BE CAPABLE OF AUTOMATICALLY MODULATING OUTSIDE AND RETURN AIR DAMPERS TO PROVIDE 100% OF THE DESIGN SUPPLY AIR AS OUTSIDE AIR TO REDUCE OR ELIMINATE THE NEED FOR MECHANICAL COOLING. 1413.3: AIR AND WATER ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET THE COOLING LOAD. 1414.1: DUCTWORK (OTHER THAN ROUND OR FLAT OVAL) WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED. 1414.1.2: ALL LOW PRESSURE DUCT SYSTEMS SHALL BE SEALED TO A LEAKAGE RATE NOT TO EXCEED 6% OF THE FAN FLOW IF THE DUCT SYSTEM HAS MORE THAN 25% DUCT SURFACE AREA LOCATED IN ANY UNCONDITIONED SPACE. THE LEAKAGE RATE SHALL BE CONFIRMED THROUGH FIELD VERIFICATION AND DIAGNOSTIC TESTING, IN ACCORDANCE WITH SMACNA DUCT LEAKAGE TEST PROCEDURES - 1985. 1414.1.3: DUCT WORK DESIGNED TO OPERATE IN EXCESS OF 3" WATER COLUMN SHALL BE LEAK TESTED IN ACCORDANCE WITH SMACNA DUCT LEAKAGE TEST PROCEDURES - 1985. 1414.2: INSULATION OF SUPPLY, RETURN AND OUTSIDE AIR DUCTWORK SHALL MEET THE REQUIREMENTS OF CHAPTER 13, DAMPERS SHALL COMPLY WITH SECTION 1412.4.1 BE INSULATED IN ACCORDANCE WITH TABLE 14 -5. 1416.2.1: BUILDINGS WHICH REQUIRE A COMMISSIONING PROCESS IN ACCORDANCE WITH WSEC SECTION 1416 AND SHALL INCLUDE: 1. COMMISSIONING PLAN 2. SYSTEMS TESTING AND BALANCING 3. HVAC EQUIPMENT AND CONTROLS FUNCTIONAL TESTING 4. SUPPORTING DOCUMENTATION IN THE FORM OF OPERATION AND MAINTENANCE AND RECORD DOCUMENTS 5. COMMISSIONING REPORT. 1416.3.3: ALL HVAC SYSTEMS, EQUIPMENT AND CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH SEQUENCES OF OPERATION PRESCRIBED IN THE CONSTRUCTION DOCUMENTS. WRITTEN PROCEDURES WHICH CLEARLY DESCRIBE THE INDIVIDUAL SYSTEMATIC TEST PROCEDURES, THE EXPECTED SYSTEMS' RESPONSE OR ACCEPTANCE CRITERIA FOR EACH PROCEDURE, THE ACTUAL RESPONSE OR FINDINGS, AND ANY PERTINENT DISCUSSION 1416.3.4.2: TRAINING OF THE MAINTENANCE STAFF FOR EACH EQUIPMENT TYPE AND /OR SYSTEM SHALL INCLUDE AS A MINIMUM: 1. REVIEW OF SYSTEM DOCUMENTATION. 2. HANDS -ON DEMONSTRATION OF ALL NORMAL MAINTENANCE PROCEDURES, NORMAL OPERATING MODES, AND ALL EMERGENCY SHUTDOWN AND START -UP PROCEDURES. 3. TRAINING COMPLETION REPORT. 1416.3.5: THE COMMISSIONING REPORT SHALL BE COMPLETED AND PROVIDED TO THE OWNER. THE COMMISSIONING REPORT SHALL INCLUDE: 1: COMPLETED FUNCTIONAL TEST FORMS INCLUDING MEASURABLE CRITERIA FOR TEST ACCEPTANCE. 2: ISSUES LOG OF CORRECTED AND UNCORRECTED DEFICIENCIES WITH THE ANTICIPATED DATE OF CORRECTION. 3: DEFERRED TESTS, WHICH CANNOT BE PERFORMED AT THE TIME OF REPORT PREPARATION, WITH ANTICIPATED DATE OF COMPLETION. 4: RECORD OR PROGRESS AND COMPLETION OF OPERATOR TRAINING. 5: COMPLETED COMMISSIONING COMPLIANCE FORM. 1416.4: A COMMISSIONING, COMPLIANCE CHECKLIST SHALL BE SUBMITTED TO THE BUILDING OFFICIAL UPON SUBSTANTIAL COMPLETION OF THE BUILDING. THE CHECKLIST SHALL BE COMPLETED AND SIGNED BY THE BUILDING OWNER OR OWNER'S REPRESENTATIVE. COMPLETION OF THE COMMISSIONING COMPLIANCE CHECKLIST IS DEEMED TO SATISFY THIS REQUIREMENT. 1432.2.1: AIR SYSTEMS SERVING MULTIPLE ZONES SHALL HAVE CONTROLS TO AUTOMATICALLY RESET SUPPLY AIR TEMPERATURE BY REPRESENTATIVE BUILDING LOADS OR OUTSIDE AIR TEMPERATURE. 1435: SYSTEMS WHICH PROVIDE HEATING AND COOLING TO THE SAME ZONE SIMULTANEOUSLY ARE PROHIBITED EXCEPT AS NOTED IN SECTION 1435. 1437: THREE PHASE ELECTRIC MOTORS NOT INCLUDED IN EQUIPMENT EFFICIENCY RATINGS (LE., EXHAUST FANS, PUMPS, COOLING TOWER FANS) SHALL MEET MINIMUM EFFICIENCY RATINGS LISTED IN WSEC TABLE 14 -4A & B. REVIEWED FOR CODE COMPLIANCE APPROVED JUL L22 0 2012 City of vile, BUILDING !SION PROTECT ALL DUCT OPENINGS OF FIRE RATED ASSEMBLIES PER I.B.C. 716. INSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF SHAFT ENCLOSURES PER I.B.C. SECTION 707. INSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF FIRE PARTITIONS, FIRE WALLS, FIRE BARRIERS AND SMOKE PARTITIONS PER I.B.C. CHAPTER 7. ALL FIRE DAMPERS SHALL BE DYNAMIC TYPE, U.L. 555 RATED. ALL CEILING RADIATION DAMPERS SHALL BE U.L. 555C RATED. ALL COMBINATION SMOKE FIRE DAMPERS SHALL BE U.L. 555S RATED. INSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING PER I.B.C. REQUIREMENTS. INSTALL ALL PIPING ON ROOM SIDE OF BUILDING INSULATION. MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND DO NOT NECESSARILY REFLECT EVERY REQUIRED OFF -SET, FITTING OR ACCESSORY. COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING STRUCTURE AND ALL OTHER TRADES. THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS, PIPES, UTILITIES AND BUILDING STRUCTURE. VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. ALL MECHANICAL EQUIPMENT LOCATED IN CEILING CAVITIES THAT REQUIRE ELECTRICAL CONNECTION SHALL HAVE AN 8 -1/2 "x11" LAMINATED SIGN PERMANENTLY MOUNTED ON THE ELECTRICAL ENCLOSURES THAT INDICATES: "THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36" (LESS THAN 460V) AND 42" (460V AND ABOVE) ". NO TRADE SHALL BLOCK THIS SPACE EVEN IF SHOWN ON THE DRAWINGS. INSTALL SIGN PRIOR TO INSTALLATION OF EQUIPMENT. ALL MECHANICAL EQUIPMENT THAT REQUIRES ACCESS FOR COIL PULL, FILTER CHANGE, MOTOR CHANGE, COMPRESSOR CHANGE, LUBRICATION, SHEAVE AND BELT CHANGE, FAN CHANGE OUT, ETC. SHALL HAVE AN 8 -1/2 "x11" LAMINATED SIGN PERMANENTLY MOUNTED ON THE EQUIPMENT ACCESS PANELS THAT INDICATES "THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36 ". NO TRADE SHALL BLOCK THIS SPACE. DUCTLESS SPLIT SYSTEM EQUIPMENT SCHEDULE MARK LOCATION COOLING CAPACITY REFRIGERATION CONNECTION ELECTRICAL OPER. WEIGHT SOUND (DBA) BASIS OF DESIGN SERVES REM ARKS BTUH REFRIGERANT CFM LIQUID SUCTION VOLT /PHASE MOCP MCA SEER INDOOR OUTDOOR INDOOR OUTDOOR MANUFACTURER MODEL AC- 1 /CU -1 SERVER ROOM 24,000 R410A 659 1/4 5/8 208 -230/1 20 11.5 17.5 31 88 48 56 FUJITSU 24CL SERVER ROOM 1,2,3 1) SELF CONTAINED CONTROLS. PROVIDE PERMANENT MOUNT FOR WIRED THERMOSTAT 2) PUMP CONDENSATE TO APPROVED LOCATION 3) OUTDOOR UNIT (CU -1 LOCATED ON TREATED, GALV. SHEETMETAL CAPPED ROOF SLEEPERS. MOUNT SLEEPERS ON APPROVED ROOF PADS AREA OF WORK SEPARATE PERMIT REQUIRED FOR: % ❑ Mechanical Electrical 14plumbing 10Gas Piping City of Tukwila BURPING DIVISION No changes shall lelmade to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review foes. LEGEND ~O I l 11 OFD r20051 129ft2 SUPPLY DIFFUSER RETURN GRILLE EXHAUST FAN VOLUME DAMPER CAP FLEX DUCT DIRECTION OF AIRFLOW THERMOSTAT POINT OF CONNECTION DEMO MOTORIZED DAMPER FIRE DAMPER ROOM NUMBER AREA OF ROOM TYPE AND NOTE [R] _ [N] _ [E] _ SIZE \--CUBIC FEET PER MINUTE r RAG 12x2 FILE COPY Permit No.. i1AV2 - -1V °1 plan review approval is to errors and omissions. Approval of construction documents does not authorise the violation of any adopted axle or ordinance. Receipt of approve! Field !edged: RELOCATED NEW EXISTING City Of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA UL 13 2012 J PERMIT CENTER MlLHO � NOTE: r 0 U ro U (3) ro ro 0 ro a a) ■. U T 4-- CS 0 co 1 3132 N.E. 133 ST Seattle, Washington 98125 -4423 PO Box 27073 Seattle, Washington 98165 -1473 (206) 367-2500 Fax (206) 368 -6856 PSRHVMS924JT D � Z W Z w O D Z ° Q ~ W W W > ct = W ct W ?� O w UZ NTERNATIONAL FOR MEASUREMENT SYSTEMS z 0 J w z w ILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. General Notes 1 11 "x17" SHEET SIZE NTS. PERMIT SET 7/11/12 Revision /Issue Drawn By P. GOTO Date, 1 Date 11 JULY 2012 Lead Tech Engineered By Date Project P4729 Project Manager SIN sale VARIE [1] PROVIDE RUN -OUT DUCT AND ER FLEXIBLE CONNECTION SAME SIZE S AS DIFFUSER NECK DIAMETER. (FIELD VERIFY BEST LOCATION) 0' Sheet M 0.0 di • ./ ,/ SITE N / AP 1 177' -10" ► 1 /32 " =1' REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 0 2012 City of Tukwila BUILDING DIVISION 1 ► 1 1 ► 1 1 1 ► 1 1 ► ► 1 1 1 1 ► 1 ► RECEIVED CITY OF TUKWILA JUL 13 2012 PERMIT CENTER 3132 N.E. 133 ST Seattle, Washington 98125 -4423 PO Box 27073 Seattle, Washington 98165 -1473 (206) 367 -2500 Fax (206) 368 -6856 PSRHVMS924JT J Q Z 0 E - H Z o Z n 0 N D W w H I- m = 2 Z 0 0 Z 0- °o %I u m co 2 � w �' WW W I--Wvz - > am W Ce ce iii L H Z cp d- ill u) V' Z FOR MEA TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. General Notes 1. 11 "x17" SHEET SIZE NTS. Date 11 JULY 2012 Lead Tech Engineered By Date 1 PERMIT SET 7/11/12 No. Revision /Issue Date Drawn By P. GOTO Date 11 JULY 2012 Lead Tech Engineered By Date Project P4729 Project Manager N. SINGER Scale 1 /32 " =1'0" Sheet M 0.1 KEY PLAN SCALE NOTE: AREA OF WORK 1 #100 RSC 2 -3 \ 4 -60 ZD �0/ 3A \\ '� �� 2 -3A \ � 4-48 ) i TQ' \ . 0 \ \O! J \ 2D ZD ZD 3B �RSC> 2 -3 //‘, 1 4B ZD RSC 2 -4 ZD 3C \O� t \ REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 0 2012 City of Tukwila BUILDING DIVISION ZD 3D \\ \ \ \o . \ 1 • RSC 2 -14 NO/ o / \ 2 -4A PARTIAL 2ND FLOOR DE\40 PLA\ 2 -14B BPD \ ■ i A/C 3 2 -14B / BPD 4A ZD - - - -- I - __ 3/16 " =1' DEMO NOTES 1) RELOCATE (1) SUPPLY AIR DIFFUSER OUT OF NEW SERVER ROOM AND INTO ADJACENT AREA. M(i (o' CITYECEIVED OF TUKWILA JUL 1 3 2012 PERMIT CENTER l • Mooing= 1 3132 N.E. 133 ST Seattle, Washington 98125 -4423 PO Box 27073 Seattle, Washington 98165 -1473 (206) 367-2500 Fax (206) 368 -6856 ` PSRHVMS924JT z a. J I— Oz w� 00 ct0 O Q O D J w ce zw N U) J aw I..V 0 z 0 i- < z w z FOR MEASUREMENT SYSTEMS CO z 0 5 m w 1- z w u_ O 0 N w 1- 5 1- 0) w z m Z TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. l General Notes 1 1. 11"x17" SHEET SIZE NTS. Date 11 JULY 2012 Lead Tech Engineered By Date 1 PERMIT SET 7/11/12 `No. Revision /Issue Date, Drawn By P. GOTO Date 11 JULY 2012 Lead Tech Engineered By Date Project P4729 Project Manager N. SINGER Scale 3/16 " =1'0" Sheet M 1.0 KEY PLAN SCALE NOTE: AREA OF WORK 1— 1 u \ 00J �R C) 2 -3 '0 I N. ZD 3A N\\ 2 -3A 4 -48 4 -60 4 2 -3B I 1 AC -1 2D ZD /' 2-4B 4-41 lei 4B ZD 3B 7 it /\\Allim RSC 2 -3 ) 2 -3C 4 -59 3C REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 0 2012 City of Tukwila BUILDING DIVISION ZD 3D \o REFRIGERANT PIPING \ UP TO ROOF \ PIPE CONDENSATE TO NEAREST APPROVED LOCATIN 1 ■ 1 i 6 4-49 T 2 -2D ZD RSC ) 2 -4 'O / I0. • RSC 2 -14 O . . I ' 2 -4A 4 -43 PARTIAL 2ND FLOOR HVAC PLAN 2 -14B BPD (RO13 \ 2 -14B �i BPD JA/C3 - - - - - - - - - . ► _ 1 4A ZD N. -r 3/16 " =1' 2 -3D 4 -58 - HVAC NOTES 1) INSTALL NEW 2 TON COOLING ONLY DUCTLESS SPLIT SYSTEM TO NEW SERVER ROOM. 2) INSTALL REFRIGERANT PIPING TO CONDENSING UNIT ON ROOF. 3) PUMP CONDENSATE TO NEAREST APPROVED DISPOSAL LOCATION. 4) MOUNT FACTORY WIRELESS THERMOSTAT ON WALL OF NEW SERVER ROOM. 5) NEW UNIT CONFORMS WITH SECTION 1344 OF THE 2009 WASHINGON STATE ENERGY CODE EXCEPTION 9. UNIT IS MORE THAN 15% OVER MINIMUM EFFICIENCY IN TABLE 14-1A, AND USED FOR A DEDICATED SERVER ROOM. Mir -ia� c r1 OflUKWIIA JUL 1 32012 PERMIT CENTER 3132 N.E. 133 ST Seattle, Washington 98125 -4423 PO Box 27073 Seattle, Washington 98165 -1473 (206) 367 -2500 Fax (206) 368 -6856 PSRHVMS924JT Z J a_ ~ 0 Q _0 oC O 0 C 0 -I W LL > 0Q Z W N (/) J 17( Z LL 0 FOR MEASUREMENT SYSTEMS m c9 z 0 m w 1- z w TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. General Notes 1 1. 11 "x17" SHEET SIZE NTS. Date 11 JULY 2012 Lead Tech Engineered By Date 1 PERMIT SET 7/11/12 `No. Revision /Issue Date Drawn By P. GOTO Date 11 JULY 2012 Lead Tech Engineered By Date Project P4729 Project Manager N. SINGER Scale 3/16 " =1' Sheet M 2.0 J KEY PLAN SCALE NOTE: AREA OF WORK NEW SLEEPERS ROOFED IN MY OTHERS CU -1 REFRIGERANT LINES UP FROM 2ND FLOOR Unit #B -3 EXISTING UNIT REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 0 2012 City of Tukwila BUILDING DIVISION PARTIAL ROOF HVAC PLA 3/16 " =1' ROOF NOTES 1) INSTALL NEW WOOD SLEEPERS WITH SHEET METAL CAPS ON ROOF. 2) ROOF SLEEPERS ONTO ROOF (BY OTHERS) 3) INSTALL DOG HOUSE AROUND REFRIGERANT PIPING PENETRATION IN ROOF. 4) ROOF IN DOGHOUSE (BY OTHERS) R CEiVEi� ,. CITY' F TUPNVILA JUL 13 2012 PERMIT CENTER r ro ft, U V N CZ til • 3132 N.E. 133 ST Seattle, Washington 98125 -4423 PO Box 27073 Seattle, Washington 98165 -1473 (206) 367 -2500 Fax (206) 368 -6856 ` PSRHVMS924JT Z F. Q — ^J Z 2 <0 >O OW O> L.1. _I W QC!) I— w 1..� Z J z 0 1- Q z cc w z FOR MEASUREMENT SYSTEMS 0 0 N W H CO co �_ Z J 5 mW W z w wa o ZZ Q m C4 �W E- Z 0 N TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. General Notes 1. 11 "x17" SHEET SIZE NTS. Date 11 JULY 2012 Lead Tech Engineered By Date 1 PERMIT SET 7/11/12 No. Revision /Issue Date Drawn By P. GOTO Date 11 JULY 2012 Lead Tech Engineered By Date Project P4729 Sheet M 2.1 Project Manager N. SINGER Scale 3/16 " =1'0" 28' 26' -4" A 24' 27' EXISTING 3'6" PARAPET AC -1 -s" v 16 Project Manager EXISTING 3'6" PARAPET 1 1 1 1 M 3.0 1 1 PERMIT SET n 1 I I I Revision /Issue Date, • ' 26' -4" 2f EXISTING ROOF _,I_b 24 ' 15 i „ -6 1 I I L EXISTING ROOF' NORTH ELEVATION 3/32 " =1' AC -1 1 EXISTING 3'6" PARAPET EXISTING ROOF EXISTING GRADE REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 0 2012 City of Tukwila BUILDING DIVISION EXISTING 3'6" PARAPET EXISTING ROOF' L _1 15' -6" 6' 27' 6" EXISTING GRADE WEST ELEVATION 3/32 " =1' ti 1 to Rt CEIV CITY OF TO JUL 1 3 2012 PERMIT CENTER ›. rO = • ro O E L)lrDI O • I— .c V C -2 O ra C/) N V t 8 a) I) • : U) wcrt 4- Ul •— a.= CO 3132 N.E. 133 ST Seattle, Washington 98125 -4423 PO Box 27073 Seattle, Washington 98165 -1473 (206) 367 -2500 Fax (206) 368 -6856 PSRHVMS924JT J J z 0 z 1- z V) U) (1) z w w v, Cw NG I.L 0 m z 0 5 w z w a Q O 0 N w 5 m 1- 0 w z w z w 1- z O N TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. , General Notes \ 1. 11 "x17" SHEET SIZE NTS. Sheet Project Manager N. SINGER M 3.0 Scale 1 PERMIT SET 7/11/12 `No. Revision /Issue Date, Drawn By P. GOTO Date 11 JULY 2012 Lead Tech Engineered By Date Project P4729 Sheet Project Manager N. SINGER M 3.0 Scale 3/32 " =1'0"