Loading...
HomeMy WebLinkAboutPermit M12-113 - WESTFIELD SOUTHCENTER MALL - CHICKEN NOWCHICKEN NOW 2600 SOUThCENTER MALL FC -11 M12 -113 Parcel No.: Address: City o#I'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT 9202470010 2600 SOUTHCENTER MALL TUKW Project Name: CHICKEN NOW Permit Number: M12 -113 Issue Date: 08/02/2012 Permit Expires On: 01/29/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: Address: Email: DAVID BODMER 2100 196 ST SW, SUITE 122 , LYNNWOOD WA 98036 DAVID @DBSOLUTIONSNW. NET Contractor: Name: D/B SOLUTIONS LLC Address: 10627 90 ST NE , LAKE STEVENS WA 98258 Contractor License No: DBSOLSL934BK Phone: 425 -744 -6300 Phone: 425 737 -4042 Expiration Date: 01/29/2013 DESCRIPTION OF WORK: RELOCATE KITCHEN HOOD Value of Mechanical: $3,500.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied arrui with, Fees Collected: $233.13 International Mechanical Code Edition: 2009 Date: 2 Led this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: 11111.—j Print N This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: 01 Z/ / doc: IMC -4/10 M12 -113 Printed: 08 -02 -2012 PERMIT CONDITIONS Permit No. M12-113 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 14: All new automatic fire - extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 15: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 16: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 17: U.L. central station supervision is required. (City Ordinance #2327) 18: A 110 candela horn/strobe shall be installed above the kitchen hood suppression system's manual pull station. doc: IMC -4/10 M12 -113 Printed: 08 -02 -2012 19: All new fire alarm systems or mo ications to existing systems shall have the w n approval of The Tukwila Fire Prevention Bureau. No work shall c ence until a fire department permit has bee tained. (City Ordinance #2328) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 22: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M12-113 Printed: 08 -02 -2012 CITY OF TUKWtA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Mechanical Permit NQ. f D--1 Project No. Date Application Accepted: —7—— 12, Date Application Expires: --,2.0 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION 2 King Co Assessor's Tax No.: Site Address: t Se, tit` T cc a. ST't t Suite Number: F' G 1 1 Floor: Z Tenant Name: 1 vJ New Tenant: ❑ Yes j..No PROPERTY OWNER Name: Name: ,-` w":‘-1TP:1,64-b. 60eme..crr o4.1 City: L. yo )1'J00.D State: Wdi Z1p:1�v3� Address: il10b 1 +Lb1.11r-G 1 A11/A Email: O qV� „ ch73Sol IA City: �Olrc�Ss State: G11 Zip:g00Z5. CONTACT PERSON - person receiving all project communication Name: Address: Z1DD let (o �1 ST 614 ti+i IZi City: L. yo )1'J00.D State: Wdi Z1p:1�v3� Phone:1 �5 ,.i .4,4 • b300 Fax: 4zs , "1,i4 . (,34 k Email: O qV� „ ch73Sol IA MECHANICAL CONTRACTOR INFORMATION Company Name: �Lu710'15 Address: 21 00 9 `7 &T ti .,T.- 6 KI 1,4 ►TL City: ��INNwooD State: deg Zip:, Phone: z5144 . X300 Fax: AZ5,744 ,fo3Ai Contr Reg No.:I DL.S L 934 ,gam Date: 11•I Tukwila Business License No.: /r i in' t t `l,„ fd 4 Valuation of project (contractor's bid price): $ 3"5—C.O Describe the scope of work in detail: �/ ( EL_C. 4 /AT � tT`NL 1S #.00 U's1: Residential: New ❑ 11i1 Commercial: New ?I Fuel Type: Electric ❑ Gas Replacement Replacement Other: H: \Applications \Forms- Applications On Line \2011 Applications \Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <IOOk btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm /industrial Unit Type Qty Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment 1_ v c 1L t. flay Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERM =IT APPLI'CA4FCO.N }NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR THORI D AGENT: Signature: Date: l \'* \ZZ Print Na {{ Mailing Address: 7-100 (°t / 1-61 3r �t�f rzt. %/,,,w 00.0. / U►k 4030342, City State Zip Day Telephone: 4z5 '144 - (o3 0 D H: \Applications \Fours- Applications On Line \2011 Applications \Mechanical Permit Application Revised 8 -9 -1 I.docx Revised: August 2011 bh Page 2 of 2 • • City of Tukwila / \ Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.e.ov RECEIPT Parcel No.: 9202470010 Permit Number: M12 -113 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/20/2012 Applicant: CHICKEN NOW Issue Date: Receipt No.: R12 -02175 Initials: User ID: WER 1655 Payment Amount: $233.13 Payment Date: 07/20/2012 03:55 PM Balance: $0.00 Payee: SOLUTIONS NORTHWEST LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3252 233.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 186.50 000.345.830 46.63 Total: $233.13 doc: Receipt -06 Printed: 07 -20 -2012 INSPECTION RECORD Retain a copy with permit: INSPECTION NO. PERMIT NO ; CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: ( / f 1� f r (i -1C-n ! 4! o (N Type f Inspection -1-4.. Ni / • :;j: Address: 7 _ CO ,3 _.S C.._ Date Called: 60 A_Dij Special Instructions: p Date Wanted: :(J (7 , p.m. Requester: Approved per applicable codes. Corrections required-'prior to approval. COMMENTS: 0-e `"--C— c -cam r ii Inspecto : n REINSPECTION FEE REQUIRED. Prior`to next inspection fee mustbe paid at 6300 Southcenter Blvd., Suite 100. Call to schedutereinspection `: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 R (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 �F'-- NI (L3 Project: a �� , c -k- -A.1 Al U r Type of Inspections ._s v l 7.--, --� AS L1(,E r , 'OA Address: 2.,Ct?O0 sc 4 Date Called: �.-Jcd( .4 /e� 6-1 6-- Special Instructions: " 1 Date Wanted:., a.m. - Z__ .._ rp:mi, Requester: Phone 25- -!73'? -4042. Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: P Date: ` n REINSPECTION FEE REQUIRE. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING.DI.VISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 1e, (206) 431-3670 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection:. •(� Address: l 4e 0 0 W( /lM ( Date Called: - .. Special Instructions: • U - --4i 3 ( INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: Type of Inspection: :: s,,, r"'4, z) ,., i i'- Vti_ �. (::*1 Address: 7(_ 00 5; C. o ev, Suite #: < ? r Contact Person: ` Special Instructions: 4d ' (] 1(-: ' :: ( i' d` i ".„ �4 -oc 1.? sc._ Phone No.: C-J' C._'<, Approved per applicable codes. Corrections required prior to approval. `COMMENTS:: Sprinklers: ` Q > Fire Alarm: '-;' :: s,,, r"'4, z) ,., i i'- Vti_ �. (::*1 Hood & Duct: %?' c. 5. Monitor:. r. �' ,; V t _ ; ; ='. v'-. (=. ,44-` Pre -Fire: Permits: 4d ' (] 1(-: ' :: ( i' d` i ".„ �4 -oc 1.? sc._ )(-1, C-J' C._'<, \--,,,-.-z>. . Needs Shift Inspection: ;- t o. Sprinklers: ` Q > Fire Alarm: '-;' , Hood & Duct: %?' c. 5. Monitor:. ; ..v-, Pre -Fire: Permits: Occupancy Type: IS Inspector: ' :. _ - ,, s Date: 3, t .,‘ ;- , Hrs.: • $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 I(ra.zari & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION DATE: 7 -27 -12 PROJECT #: 066 -12157 PROJECT: Chicken Now LOCATION: South Center Mall KRAZAN P.M.: Bill Throne «it_CEIVED art r OF TUKWILA FIELD AUG 10 20121 REPORT NO.: agiMIT CONTRACTOR: PERMIT #: INSPECTOR: Chris Johnson JURISDICTION: City of Tukwila WEATHER: Overcast TEM Krazan and Associates representative on site as requested to perform Duct inspection. Upon arrival met with contractor and reviewed plans and specifications. Performed interior and exterior visual inspection of each section of the Kitchen Exhaust Hood Duct. It appeared as though each section of the Duct was connected soundly by welds that showed no sign of weakness in accordance with the requirements of the construction documents. Reviewed By: VT'' ASTM Test #: Equipment/Asset Number(s): To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications, and regulatory requirements. Supertntendent/Represenlative: Technician: 1501 Field Report Offices Serving the Western United States Revision 5 Effective Date: 7 -29-11 Bothell (425) 485 -5519 • Poulsbo (360) 598 -2126 • Puyallup (253) 939 -2500 iheidedeion pro ded co lhie report h yapad tbr the reins= oie ore* ahem. The report may oat bo goodicol le say format without the =boo pendaa® ofthnched and Kaman d Aradmo:. Thb repon edema our inspectors obwntie ad totes rode bind ee site =diem sod =dome the damnation is =Ides to =tot prior m find submittal By dotesdd, repot our =sector does Dot accept rapordehty for=kik erode. The IMO httanMian Wr hem podded by etas an tie. Page 1 of 1 July 31, 2012 Project: Chicken Now /Westfield Southcenter Mall Subject: 3M Fire Wrap "Put Our Service To The Test!" The new install of 3M fire wrap insulation is 2 layers and provides a 2 hour rated wrap per code and we provided and installed (2) 2 hour rated access doors. Rick Moisant Mechanical Resource Services, Inc. 425- 673- 55800ffice 425 - 673- 5680fax 206 - 510- 7349Ceii 3129 RUSSET ROAD, BRIER, WA 98036 - (425) 673 -5580 - FAX (425) 673 -5680 Krazan pkis;i iVED AUG 2 0 20121. & ASSOCIATES INC rnf wtuF,tff_ GEOTECHNICAL ENGINEERING • ENVIRONMENTAL Weer CONSTRUCTION TESTING AND INSPECTION DATE: 7 -27 -12 PROJECT #:066 -12157 PROJECT: Chicken Now LOCATION: South Center Mall KRAZAN P.M.: Bill Throne FIELD REPORT NO.: 12157DFR072712 -CJ CONTRACTOR: PERMIT #: ifjno INSPECTOR: Chris Johnson JURISDICTION: City of Tukwila WEATHER: Overcast r „/4' TEM 6 .1 Krazan and Associates representative on site as requested to perform Duct inspection. Upon arrival met with contractor and reviewed plans and specifications. Performed interior and exterior visual inspection of each section of the Kitchen Exhaust Hood Duct. It appeared as though each section of the Duct was connected soundly by welds that showed no sign of weakness in accordance with the requirements of the construction documents. Reviewed By: il`y'9 ASTM Test #: Equipment/Asset Number(s): To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications, and regulatory requirements. Technician: Su perintendent/Representative: 1501 Field Report C . )o,ScrA Offices Serving the Western United States Revision 5 Effective Date: 7 -29 -11 Bothell (425) 485 -5519 • Poulsbo (360) 598 -2126 • Puyallup (253) 939 -2500 The information providul on this rayon is preparul for the cclusive use of the dim. This report may not he repnducat hl any format without the wrinat nu-mission of the ,lion mid tiv/yt & Assmiato. This 'won indicatvti Our inspn-mrs obsuvation and lusting results basal on site undilitnis and u,nuaunr activitio. This udbrmation is subject to review prior to final subininal By signing this report, our inspector does not accept responsibility for validity of faults. The same information has Iwo provided by others on site. Page 1 of 1 PERMIT CO i 7 COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -113 DATE: 07 -20 -12 PROJECT NAME: CHICKEN NOW SITE ADDRESS: 2600 SOUTHCENTER MALL, FC -11 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 1 J L o l7' V1 41A/\ I L --y(0- u. Bwldin "Division re Prevention Planning Division 9 Public Works Structural n Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 07 -24 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRE DUE DATE: 08-21-12 Approved with Conditions ki Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pr Friendly Page General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name D/B SOLUTIONS LLC UBI No. 602667064 Phone 4257446300 Status Active Address 2100 196Th St Sw, Ste 122 License No. DBSOLSL934BK Suite /Apt. License Type Construction Contractor City Lynnwood Effective Date 1/29/2007 State WA Expiration Date 1/29/2013 Zip 98036 Suspend Date County Snohomish Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company D/B SOLUTIONS NORTHWEST, LLC Business Owner Information Name Role Effective Date Expiration Date D/B SOLUTIONS, LLC Partner /Member 01/12/2007 Bond Amount Received Date BODMER, DAVID HENRY Partner /Member 10/05/2009 01/10/2008 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 CBIC SG7910 01/10/2008 Until Cancelled 01/10/2013 $12,000.0010/05 /2009 1 CBIC SG7910 01/10/2007 10/05/2009 01/10/2011 01/10/2012 $6,000.0001/29/2007 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 Co ntury Surety CCP733008 01/10/2012 01/10/2013 $1,000,000.00 01/09/2012 5 CENTURY SURETY CO CCP679163 01/10/2011 01/10/2012 $1,000,000.0001 /10/2011 4 FIRST MERCURY INS CO FMWA001022 01/10/2010 01/10/2011 $1,000,000.00 01/07/2010 3 FIRST MERCURY INS CO FMWA0000042 01/10/2009 01/10/2010 $1,000,000.00 01/09/2009 2 FIRST MERCURY INS CO FMWA000004 01/10/2008 01/10/2009 $1,000,000.00 01/14/2008 1 CAPITOL SPECIALTY INS CORP CS00335826 01/10/2007 01/10/2008 $1,000,000.0001 /29/2007 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 08/02/2012 mod• ®�c �� tips fiEMODEU$G DRAWING INDEX �� M�. -�i �� ,� -1 �+® ®Oy �tp. ����® $�® $ITT CMS► �i �k S P r =Mx, D� r FI H sc °i • +�O � s�Cn® I� H, s C,. PLUMBING MODIFICATION CODE: •IBC (2009) WITH WASHINGTON STATE AMENDMENTS BUILDING • N.E.C. (2006) WITH WASHINGTON STATE AMENDMENTS • LM.C. (2009) WITH WASHINGTON STATE AMENDMENTS- • U.P.C. (2009) WITH WASHINGTON STATE AMENDMENTS • I.F.C. (2009) WITH WASHINGTON STATE AMENDMENTS • 2009 WASHINGTON NON RESIDENTIAL ENERGY CODE OCCUPANCY CLASS: GROUP ' M ' NONCOMBUSTIBLE CONSTRUCTION TYPE: TYPE II B , UNPROTECTED TOTAL LEASED AREA: 600 S.F. MAXIMUM ALLOWABLE AREA: — 600 S.F. OCCUPANT LOAD: 5 WORKERS AT ALL TIME 36" INCHES REQUIRED EXIT WIDTH: 36" INCHES PROVIDED EXIT WIDTH: •it Ir1 r , r I 14 J SPACE EC1 1 GENERAL NOTES 6\33 SO , � c.E. 1. THESE DOCUMENTS REPRESENT THE SCOPE OF WORK TO BE TO PERFORMED BY THE GENERAL CONTRACTOR ( UNLESS OTHERWISE NOTED.J 2. CHECK DIMENSIONS AND CONDITIONS IN THE FIELD ALL DIMENSIONS AND CONDITIONS OF THIS JOB SHALL BE FIELD CHECKED BY GENERAL CONTRACTOR WHO WILL BE RESPONSIBLE FOR SAME. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE START OF CONSTRUCTION. COSTS DUE TO A FAILURE OF REPORTING THESE DISCREPANCIES WILL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 3. ERRORS AND OMISSIONS ANY DISCREPANCIES OR OMISSIONS ON THESE DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF CONSTRUCTION AND BID TO OWNER. FAILURE BY THE CONTRACTOR TO IDENTIFY DISCREPANCIES OR OMISSIONS WILL THEN BECOME THE RESPONSIBILITY OF THE CONTRACTOR. 4. COMPLY WITH DESIGN CRITERIA GENERAL CONTRACTOR TO FOLLOW AND COMPLY WITH LANDLORD'S TENANT DESIGN CRITERIA AND REQUIREMENTS FOR ALL EXHIBITS. ( IF APPLICABLE. ) 5. NOTES ALL NOTES ON ANY PORTION OF THESE DOCUMENTS APPLY TO ENTIRE DOCUMENT WHETHER OR NOT THEY ARE REPEATED IN OTHER AREAS. 6. WORK, MATERIALS AND CONSTRUCTION METHODS ALL WORK, MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM WITH ALL GOVERNING AUTHORITIES HAVING JURISDICTION. APPROVAL APPROVAL H SE GOVERNING D WI DRAWINGS Y GOVERNING S APPROVAL OF THESE DRAWINGS BY GOVERNING AUTHORITIES DOES NOT RELEASE THE CONTRACTOR FROM COMPLYING WITH ALL APPLICABLE CODES AND STANDARDS. 8. INSTALLATION BY GENERAL CONTRACTOR ALL MATERIALS AND EQUIPMENT ITEMS SUPPLIED BY THE OWNER /TENANT ARE TO BE INSTALLED BY GENERAL CONTRACTOR UNLESS INDICATED OTHERWISE. 9. MATERIALS ALL MATERIALS SHALL BE NEW AND FIRST CLASS. ALL WORK AND EQUIPMENT ITEMS SHALL BE WARRANTIED BY THE CONTRACTOR FOR A MINIMUM OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE. EXCEPT FOR MANUFACTURE'S WARRANTY WHICH MAY BE LONGER. 10. COMBUSTIBLE MATERIALS NO COMBUSTIBLE MATERIALS ARE PERMITTED ABOVE CEILING. 11. FIRE EXTINGUISHERS CAPACITY AND RATING AS REQUIRED BY N.F.P.A. PAMPHLET #10 AND LOCAL AUTHORITIES. LOCATE PER LOCAL AUTHORITIES AND N.F.P.A. 10. 12. FIRE WALLS ALL FIRE-WALL PENETRATIONS TO BE INSTALLED PER U.L. NUMBERS: WL 1001 WL 2002 WL 1002 WL 2003 WL 1003 WL 2004 WL 5002 WL 2005 13. MISC. PRIOR TO INSTALLING SHELVING IN REFRIGERATOR, T.G.C. TO WASH DOWN (SPONGE) INTERIOR THREE (3) TIMES WITH A SOLUTION OF 50% VINEGAR AND 50 %WATER. SET REFRIGERATOR OPERATE AT 34 -.38 F RANGE. SPECIAL NOTE: r ' �4,- • 9,.,181/4„., REVIEWED FOR COMPLIANCE APPRO y `' ED JUL 3 0 2012 City of ila p C�7UihDiN t ISlON sin OW4 � 1 / of I11C1C y S FUTURE RETAIL "-.+ SEPARATE PERMIT REQUIRED FOR: 0 mechanical ® • l = EXISTING LANDLORD DEMISING PARTITION NORDSTROM 1 .wb7.1ViY Plu = 3 -5/8" OR 6" SEE PLAN METAL STUDS @ 16" 0.C. C = EXISTING INTERIOR WALLS TO BE REMOVED JCP2nf12}/ Piping City Cty of TVkwiia/� BUILDING DIVISION CHICKEN B iN iO W SPACE FC11 r 600 FT. 4114r `'� PROW IO�O• _' t o R' LEVEL 2 OF 3 EMPLOYEE RESTROOMS 1;� Zi [2b ' 1 l r�l ►� 1►�� %, %�7� . tl'� J[LLI. LANDLORD: OWNER WESTFIELD CORPORATION Tenant Coordination - Southcenter 14th Floor 11601 Wilshire Blvd. LOS Angeles; CA 9OOZ5 Atterl: Josh Kimmel (31 O) $93 -4781 Ph: (310) 47$ 4456 Fx: (310) 575 5991 MAGIC WOK 3421 N. LAKE VIEW DRIVE, SUITE 168 TAMPA, FL 33618 ATTN : DAVID WU TEL (813) 265 -3955 FAX (813) 265-3428 • �_ — _ _ _ _ ..= =_, = LANDLORD. PROVIDED PUBLIC RESTROOMS U► �� ! 'p' `.. _: �. .� ., .. _ r= ., - _ , ; .. '. �'!' _ _ -� _ - CONTRACTOR AND ALL SUB - CONTRACTORS SHALL VISIT JOB SITE PRIOR TO THE BID. TO REVIEW ACTUAL FIELD CONDITIONS THAT MAY AFFECT THE BID. CONTACT ARCHITECT WITH. ANY FIELD CONDITION AFFECTING DRAWINGS BEFORE BID TO OWNER. IF NOT COMMUNICATED WITH THE ARCHITECT; THEN CONTRACTOR 8+, SUB-CONTRACTOR WILL BECOME RESPONSIBLE FOR ALL COSTS INVOLVED. '= 1 1 - �- - — -_ .. - - -- - _ � � -` - �= I I I I I I (I I I I I LJ I I - -- - suiwiNG Dot m pair. NG CONDITION 1 DomourioN NOTES G c® 0 / DEMOUTION PLAN CITY OF TUKWILA BUILDING DIVISION 6300 SOUTHCENTER BLVD #100 T3 6300 HC NTE - ATTN: PLAN REVIEW TEL.: (206) 431 3670 DEPARTMENT OF HEALTH - SEATTLE & KING COUNTY 999 3RD AVE. SUITE 1200 SUITE SEATTLE, 99 3RD VE 98104 ATTN: PLAN REVIEW TEL.: (206) 296 4600 1 GENERAL CONTRACTOR SHALL REMOVE EXISTING WALL FINISHES AT THIS AREA ONLY AS SHOWN. EXERCISE GREAT CARE IN NOT DAMAGING THE FIRE RATED DRYWALL AT THE DEMISING WALLS. IF DAMAGED, G.C. ' SHALL REPAIR AS NECESSARY AND PREPARE THE WALL TO RECEIVE NEW FINISHES PER FINISH SCHEDULE AND ELEVATIONS, THE REST OF STOREFRONT FINISHES SHALL REMAIN AS IS, SEE ELEVATIONS FOR THE XTENT OF NEW REMODEL. 2 GENERAL CONTRACTOR SHALL VERIFY THE CONDITION OF THE EXISTING WALL FINISHES IN KITCHEN AREA, RESTORE TO LIKE -NEW CONDITION, AND REPLACE AS REQUIRED. GENERAL CONTRACTOR SHALL REMOVE EXISTING NONBEARING PARTITION WALLS AS INDICATED. DISCONNECT AND REMOVE ALL EXISTING ELECTRIC, CAP 3 OFF PLUMBING (IF ANY) WITHIN REMAINING WALLS OR ABOVE CEILING, AS REQUIRED. PATCH AND REPAIR REMAINING WALL, CEILING, AND FLOOR SURFACES TO ACCEPT FINISHES AS INDICATED. 4 EXISTING GYP. BD. CEILING AT SALES AREA TO REMAIN. GENERAL CONTRACTOR SHALL RESTORE TO LIKE NEW CONDITION, PAINT PER CEILING PLAN AND ELEVATIONS ON SHEETS A -1 & A -3. 5 EXISTING HVAC SYSTEM AND EXISTING DIFFUSERS TO REMAIN. GENERAL CONTRACTOR SHALL VERIFY CONDITION OF EXISTING SYSTEM, SEE NOTE ON SHEET A -1. EXISTING LIGHT FIXTURES IN KITCHEN AND SALES AREA TO REMAIN. GENERAL CONTRACTOR TO VERIFY THE CONDITION OF ALL LIGHTING, RESTORE TO 6 LIKE -NEW CONDITION, AND RELAMP AS REQUIRED. 7 EXISTING LANDLORD BULKHEAD AND CEILING TO REMAIN. 8 CONTRACTOR SHALL COORDINATE WITH OWNER AND RELOACTE EXISTING EXHAUST HOOD TO NEW LOCATION SHOWN ON EQUIPMENT PLAN, REROUTE EXISTING EXHAUST AND MAKE UP AIR DUCT TO NEW HOOD LOCATION ACCORDINGLY 9 GENERAL CONTRACTOR SHALL VERIFY THE CONDITION OF THE EXISTING FLOORING, PRESSURE WASH, AND RESTORE TO LIKE NEW CONDITION. 10 EXISTING MALL FLOORING TO REMAIN. GENERAL CONTRACTOR TO RESTORE TO LIKE NEW CONDITION AND PATCH AND REPAIR AS NECESSARY ALONG LEASE LINE. CONTRACTOR SHALL COORDINATE WITH OWNER AND REMOVE PORTION OF EXISTING SALES COUNTER MATERIAL AND EQUIPMENT TO ALLOW FOR NEW 11 COUNTER CONFIGURATION SHOWN OF FLOOR PLAN AND EQUIPMENT PLAN. 12 EXISTING HAND SINK TO REMAIN. TO BE RELOCATED, SEE EQUIPMENT PLAN FOR NEW LOCATION. 13 AS NEE SCONTRACTOR SHALL VERIFY THE CONDITION OF EXISTING SINKS THROUGHOUT THE SPACE AND RESTORE TO LIKE NEW CONDITION, REPLACING 14 CONTRACTOR SHALL VERIFY THE CONDITION OF THE EXISTING WATER HEATER AND MOP SINK. INSTALL NEW AS REQUIRED. 15 EXISTING EQUIPMENT /FIXTURES TO REMAIN. VERIFY CONDITION. CONTRACTOR SHALL COORDINATE WITH OWNER AND REMOVE /REPLACE /RELOCATE COOKING EQUIPMENT. CONTRACTOR SHALL INSTALL RELOCATE THE GAS 16 LINES /ELECTRICAL OUTLETS ACCORDINGLY, SEE NEW EQUIPMENT PLAN CONFIGURATION. FILECOIM EXISTING ELECTRICAL POWER SUPPLY, PANELS AND TRANSFORMER TO REMAIN. SEE NOTE ON SHEET A-1. _ '� _ i4 `� ������ / //� �, �` _ 14 1 i - iY � PR ARCHITECT MOSAD ELEWA 6601 MEMORIAL HIGHWAY STE. 204 TAMPA FL 33615 TEL,: (813) 245 -6554 FAX.: (801) 218 -6554 E -MAIL: INFO @MCDART.NET DAVID HIATT ARCHITECT , 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 PHONE: (813) 289 -3336 FAX: (813) 289-3332 le m 3 ��■ �� � 1 I I rit • • ■■ - 0 / i- -- /! ! ABOVE 11 ICI I� 11 I I I I 0 15 15 11 4 5 6 ABOVE LANDLORD S I ABOVE 15 • Y I BE I ' • 6 _ 15 4/ ABOVE i 8 13 "11 • IiI 1D , 16 2 mg / !i 15 3 3 I I- 15 '� �.`�11 13 -- 15 - - - �E 1 1 ui!i ■ ei � 9 - -- - - - 15 - -. •11 3 , lh, 18 EXISTING SERVICE DOOR TO REMAIN. ADD NEW HARDWARE AS REQUIRED. W'\1 _ I11I Plan review epprnwib subject bems Approval of construction documents does the violators of any &doped code or Reid of approved Copy .._ Ind omissions. -- — 2 S o o not authorize - I — - Receipt sN�: is 12 11 �J �_ 1 — - . : . 7 -11 -12 0 �/7_ r . _ DP/ISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal I and may include additional plan review fees. es k VISIONS e made prior a • n nnOP ;r 6l h al scope of DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: ao SOUTHCENTER SPACE FC 633 SOUTHCENTER WA 98188 REVISIONS AREVISED PER LANDLORD 1/23/08 DAVID HIATT ARCHITECT 4410 W. MELROSE AVENUE TAMPA, FLORIDA33629 TEL. 813.333.2717 FAX. 813.289.3332 RECEIVED JUL 20 2012 PERMIT CENTER COVER SHEET SHEET NUMBER ci 1l2W3 OF.1 DOOR SCHEDULE 100 GENERAL CONTRACTOR SHALL VERIFY EXISTINANCE AND CONDITION OF 1 -LAYER OF 5/8" TYPE 'X' GYPSUM WALLBOARD AT ALL DEMISING WALLS. ALL DEMISING PARTITIONS ARE TO HAVE 5/8" TYPE 'X' GYPSUM WALLBOARD FROM FINISH FLOOR TO UNDERSIDE OF DECK, CONTINUOUS. PER #U425. DESCRIPTION FINISH JAM B JAM B FINISH JAMB DETAIL HARDWARE GENERAL CONTRACTOR SHALL PROVIDE F.R.T. BLOCKING AS REQUIRED FOR INSTALLATION OF NEW HAND SINK. ALL BLOCKING TO BE 3/4" F.R.T. PLYWOOD (MARINE GRADE IN. WET AREAS). SCREW FASTEN BETWEEN METAL STUDS AT NEW. PARTITIONS AND FURRED WALLS. COVER W/ 5/8" GYP BD. AND FINISH WITH PER ELEVATIONS. SEE DETAILS THIS SHEET. NOT USED EXISTING 3' -0 "x 7' -0" H.M. DOOR U.L. LABEL "B" STEEL U.L. LABEL "B" 3 STANLEY HINGES: FBB179, 4- 1 /2 "x4- 1 /2 ",NRP, 26D 1 SCHLAGE LOCK, D8OPD RHODES, 626. (LEVER HANDLE) 1 NORTON CLOSER, P8301BF SNB ALUM. 1 KICK PLATE, 12x2 "LDW, 32D 1 IVES VIEWER, 698B26D 1 STOP AS REQUIRED 3 SILENCERS 1 THRESHOLD 'PEMKO' #2005 AT DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: 1/2" GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL NEW INTERIOR PARTITION WITH 3 -5/8" METAL STUD AT 16" O.C. PART. WITH 5/8" WATER RESISTANT WALLBOARD ON BOTH SIDES OF WALL BETWEEN SALES /KITCHEN; TAPE AND SPACKLE; REMAINING INTERIOR WALLS TO HAVE 5/8" WATER RISISTANT GYP. BD. BOTH SIDES, TAPE & SPACKLE. NOT USED 9' -2 1/2„ U L- 105 WALL TILE, SOFFIT TILE AND BASES IN ROOMS WITH GYPSUM WALLBOARD WALLS SHALL BE THIN SET WITH ADHESIVE IN ACCORDANCE WITH THE TILE COUNCIL OF AMERICA, INC. ANSI A- 108.5. NOTE: ALL WALL AND SOFFIT TILE SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR. (106) GENERAL CONTRACTOR SHALL PROVIDE & INSTALL TILE T -4 ACCORDING TO. MANUFACTURERS INSTRUCTIONS FOR APPLICATION OVER GYPSUM DRYWALL. 107 GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL STAINLESS STEEL PANELS OVER GYPSUM WALL BOARD FROM TOP OF QUARRY TILE BASE TO BOTTOM OF HOOD. ALONG THE LENGTH OF THE HOOD AT BACK AND SIDES. EXIST. 5/8" TYP. "X" GYP. BD. T -4 OVER 5/8" GYP, BD. 3' -7 1/2" 3' -0" GENERAL CONTRACTOR SHALL INSTALL 1 -1/2" X 1 -1/2" 16ga.S /S CORNER GUARDS OR END CAPS FLOOR TO CEILING AT ALL OUTSIDE CORNERS WITHIN THE PREP. ROOM, SCREW FASTEN AND SEAL WITH CLEAR SILICONE. TYP. ALL OUTSIDE CORNERS. SEE DETAIL 3/A -2. NOT USED HOLLOW METAL EXISTING DEMISING WALL STUDS EXISTING' HOLLOW METAL FRAME, W/ THREE JAMB ANCHORS PER JAMB. B -LABLE EXISTING 1 3/4" H.M. B -LABLE DOOR. PAINT P -1 (BOTH SIDES AND EDGES) EXISTING LOW WALL LEASE LINE EXISTING QUARRY TILE FLOORING TO REMAIN, PRESSURE WASH AND RESTORE TO LIKE NEW CONDITION. CUT OUT FOR EQUIPMENT. VERIFY SIZE PRIOR TO CUTTING COUNTER TOP. SEE EQUIPMENT PLAN AND SCHEDULE. NOT USED EXISTING 2'X4' LAY -IN CEILING SYSTEM AS INDICATED ON REFLECTED CEILING PLAN. VERIFY CONDITION REPLACE ANY DAMAGED TILE WITH NEW. 3" =1' -0" 2' -10 1' -5" LOWING FIXTURE SCHEDULE Z U W 1:1) F.- Z = w O o H CO 0 ,o@ N 4 M M ,.. co DESCRIPTION MANUFAC. CATALOG REMARKS LAMPS/ FIXT. BAL.ASTS BALLAST/ FIXT. TOTAL WATT EXISTING 2 -LAMPS 2x4 RECESS TROFFER M ERCURY 35E2320CT9A125ELB (2) F032T8/841 RECESSED W /ELECTRONIC RAPID START BALLAST 07)114 EXISTING GYP. BD. CLG. TO REMAIN, GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL NEW 5/8" TYP. "X" GYP. BD. CEILING AND PAINT P -1 AT RELOCATED EXHAUST HOOD. GENERAL CONTRACTOR SHALL RECONFIGURE EXISTING SALES COUNTER TO ACCOMEDIATE NEW STEAM TABLE AND COLD PANS, RECONFIGURE CASEWORK ACCORDINGLY, COORDINATED WITH EQUIP FOR SIZE OF EQUIPMENT SUPPLIER BEFORE MAKING ANY COUNTER CUTOUT. SUPPLIER, SEE SECTIONS SHEET #A -4 . INSTALL ALL FINISHES AS SPECIFIED. ALL JOINTS IN AND AROUND CABINETS, SINKS, VENTILATOR, ICE BIN, ETC., TO BE SEALED WITH CLEAR SILICONE SEALANT. PROVIDE BLACK PLASTIC WIRE WAY GROMMETS AT ALL DRILLED OPENINGS. ELECTRONIC SYLVANIA QTP2X32T8 /UNV PSX -SC EXISTING 2 -LAMPS 2x4 RECESS TROFFER 11' -3" 0 1/2" MERCURY 35E232OCT9A125ELB (2) F032T8/841 RECESSED W /ELECTRONIC RAPID START BALLAST ELECTRONIC I 1 6 SYLVANIA QTP2X32T8 /UNV PSX -SC ADJACENT TENANT REVISIONS EXISTING /NEW COUNTER COVE LIGHT BARTCO LIGHTING TEL: 714 - 230 -3200 BFLSLM -14/6 28W T5 46 1/16" LAMP UNDER COUNTER COVE LIGHT MINIATURE LINEARET5 120 FLUORESCENT SINGLE WIDTH STAGGERED. 6" LAMP OVERLAP, INTEGRAL BALLAST. 24' -1" GENERAL CONTRACTOR SHALL REFURBISH ANY L.L. AREAS DAMAGED AT THE STOREFRONT TO A LIKE NEW CONDITION. ( NEUTRAL PIERS, NEUTRAL BANDS, ETC. ) EXISTING SPRINKLER AND /OR FIRE ALARM TO REMAIN. . SPRINKLER CONTRACTOR TO PROVIDE NECESSARY DOCUMENTS FOR CONSTRUCTION AND PERMITTING UNDER SEPARATE COVER TO THE ARCHITECT, LANDLORD AND GOVERNING AUTHORITIES FOR APPROVAL PRIOR TO ANY MODIFICATIONS TO THE EXISTING SPRINKLER SYSTEM. COORDINATE MODIFICATION SCHEDULE W/ L.L. FIELD REP. SYSTEM I5 TO BE FULLY CHARGED AND OPERATIONAL WHEN G.C. IS OFF SITE. FINAL SPRINKLER LAYOUT TO BE DETERMINED BY SUBCONTRACTORS SHOP DRW'GS. 119 EXISTING MECHANICAL DIFFUSERS TO REMAIN. EXISTING /NEW RECESSED DOWN LIGHT EXISTING DECORATIVE PENDANT LIGHT H274HP -120V F13DTT -Halo Z64 RECESSED SCALE: 1/4" = 1' -0" VAXCEL PD30119SN - LAVA SWIRL MINI PENDANT (1)50W 610 CAND C INCANDESCENT MPT MONOPOINT COORD W /OWNER 120 CALL LIGHTING UNIVERSE (800) 801 -2207 EXISTING EXIT LIGHT EXISTING RECESSED EMERGENCY LIGHT JUL 3 0 2012 ATLITE PNLRU, ENCORE LIGHTING ERG -630 -R ERG SERIES FURNISHED W /UNIT A PAR 36 SEALED BEAM LAMP UNIVERSAL 90 MINUTE BATT. BACKUP POWER RECESSED FULL LIGHT OUTPUT 12 FOR OP TO 4 HOURS. BATTERY CAPACITY 30 City of Tukwila BUILDING DIVISION NOTES: OELECTRICAL CONTRACTOR TO INQUIRE ABOUT LOCAL REBATES ON LIGHT FIXTURES. O INSTALLATION OF LIGHT FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S 2 RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENTS. V ALL LAMPS TO BE SYLVANIA UNLESS NOTED OTHERWISE. OPROVIDE LIGHT TUBE COVERS, LENSES, ETC., AS REQUIRED TO PROTECT FOOD SERVICE AREA. EXISTING SIGN 2 7/8' 5/8" WATER RESISTANCE GYP. BD. INSTALL FINISH PER ELEVATIONS AND NOTES. HORIZONTAL BLOCKING SUPPORT; 2 1/2" 16 GA METAL STUDS BETWEEN WALL STUDS. 3/4" FIRE RATED PLY -WOOD BLOCKING FLUSH TO BACK SIDE OF GYP.BD. 11' -0 A.F.F. BOTT. OF EXISTING SIGN BAND 11' -0" A.F.F. Type I Hood Special Inspections Type I hoods and ducts shall be inspected by approved inspection agencies that satisfy the requirements as to qualifications and reliability. Final inspection reports duct shall approved accepted by the Type I hood and the code official after the special inspections of hood and duct have been completed. (2009 IMC 107.2.4 & IMC 506.3.2.5) .4 EXISTING SUSPEND CEILIN (SCP -1) EXTEND BEYOND MIN. OF 6" FDRURE OR EQUIPMENT. 12' -10 ": BOTT. OF NEW GYP. BD. & CLG. AT HATCHED AREA 12' -0" A.F.F. BOTT, OF EXISTING SOFFIT NEW MENU BOARDS SINK WITH LEVER HANDLE FAUCET A.CEA OF BLOCK'G. SHOWN HATCHED. •aaq L 1er•ri■ 3 5/8" M.S. SEE EQU PMENT PLAN FOR PLUMBING ACCESS. SCHEDULE BLOCK'G. PER DETAI THIS SHEET. F.F. EXISTING RECESSED FLUOR. LIGHT FIXT. \ 7' -0" A.F.F. BOTT. OF EXISTING SOFFIT 12' -10" BOTT. OF EXISTING GYP. BD. & CLG. 114 SECTION: NON DEMISING MOW. SCALE: AS NOTED 7' -0" A.F.F. BOTT. OF EXISTING SOFFIT NO SCALE TION OEM LEASE LINE EXISTING RECESSED LIGHT FIXT. a"w..ra JAM, ....wA.NM* • NOTE. ALL LIGHT FIXTURES ABOVE THE SERVICE, PREPARATION, UTENSIL WASHING AND FOOD STORAGE AREAS (INLCUDING THOSE LIGHTS WITHIN STEAM TABLES, REFRIGERATION UNITS HOODS AND COOKING EQUIPMENT) SHALL BE SHIELDED OR EQUIPPED WITH SHATTER -PROOF BULBS. EXISTING RELOCATED EXH. HO REMOVE PORTION CLG. TO ALLOW FOR THE INSTALLATION OF RELOCATED HOOD. REFLECTED CC1.01 KAN SCALE: 1/4" = 1' -0" M12= 113 DAVID HIATT ARCHITECT 44.10 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.27w FAX. 813.289.3332 RECEIVED JUL 20 2012 PERMIT CENTER FLOOR PLAN, CEILING PLAN &NOTES SHEET NUMBER A-1 OF.5 EQUIPMENT *= EXISTING TO REMAIN *R = EXISTING RELOCATED N = NEW IBLOCKING I OREV ®NS: CLASS ABC FIRE EXTINGUISHERS. EXTINGUISHERS MARK RESPONSIBILITY ITEM/ QNTY DIMS SPECIFICATIONS: REMARKS: FLOOR ` � SHALL BE CONSPICUOUSLY LOCATED AND READILY ACCESSIBLE. THE TOP OF THE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT. ABOVE THE FLOOR AND THE BOTTOM OF THE EXTINGUISHER SHALL NOT BE LESS THAN 4 INCHES ABOVE THE FLOOR: EXTINGUISHERS SHALL BE INSTALLED IN ACCORDANCE WITH CLASSIFICATION, RATING, AND DISTRIBUTION REQUIREMENTS OF NFPA 10. [NFPA 1: 13.6.1.2] ~� ® �.� '� ... �.4 ® i • � - -- O "DAL -TILE 6 "X6" "ARID GRAY" #Q42 SMOOTH ABRASIVE TILE HAS WET-DRY Q * 1 SERVICE COUNTER (CSCI) 1 VARIES SEE PLAN EXISTING, MODIFY PER PLANS AND SECTIONS PROVIDE AND INSTALL MARINE GRADE PLYWOOD AT ALL WET AREAS INCLUDING BEVERAGE AND STEAM TABLE AREAS. QT -1 C S.C•O.F. OF 0.73 -0.90 INSTALL WITH CADET GRAY COLOR GROUT. SEE CONSTRUCTION NOTES AND SPECIFICATIONS FOR INSTALLATION PROCEDURES. * 2 POINT OF SALE SYSTEM (OSCI) 3 cash) #QT -8000 BASE N 3.0 3-WELL STEAM TABLE W/ OVERSHELF & SNEEZGUARD (OSCI) 1 43 -1/2 W 19 -7/8" D ATLAS METAL WIH -3 208 V, 2,55 KW, 12.3 AMPS CUT -OUT REQUIRED: 22 -1/4 D x 41 -3/4 W L6 -20P NEMA CONFIGURATION (TB-1 COVED TILE BASE = 6" HIGH, "'DAL- TILE" ` TO MATCH T -1 Q Q N 3A FRIED FOOD HOLDING N 1 15.8" W 24.6" D 13" H MERCO COUNTERTOP MODEL #FFHS -16, 120 VOLTS, 12.3 AMPS, 1450 WATTS. 5 -15P NEMA CONFIGURATION WALLS ® EXISTING 12X12 MOSAIC N 4 :::05d1) DROP -IN COLD PAN (OSCI) 1 45.32" W 26" D DELFIELD MODEL #8140 -EF 115 V, 60 HZ, 1 PH, 7.0 AMPS, 1/4 HP UT REQUIRED: 25.00 D x 44.25" W CUT-OUT ® 4- 1/4 "X4 -1/4" DALTILE GLASS REFLECION "WHITE ICE #CR13" N g SNEEZE GUARD (OSCI) VARIES SEE PLAN CUSTOM FABRICATED Z' TEMPERED GLASS WITH FLOUR. LIGHT FIXTURE, SEE SECTIONS FIRE EXTINGUSHERS -CLASS K ■■ ® 6 "X12" ASI PORCELAIN COLLECTION FLCCD344 PHOENIX STYLE CLASS K FIRE EXTINGUISHERS • SHALL BE PROVIDED FOR HAZARDS O t 1 BE GLASS SNEEZE * 6 BAG IN BOX 1 COKE Co. 4X4 WHITE CERAMIC TILE. "DAL -TILE" #D -100 WITH MATCHING COLORED SAND 29 WHERE THERE IS A POTENTIAL FOR J B A COOKING MEDIA. [NFPA 10 :4.3.2] CNI SIC SODA DISPENSER/ "SITCO" #WRD -6 ; REQ. 110V/20 AMP TO 3/8" W /GATE VALVE. 1 -1/2" DRAIN FIELD VERIFY EQUIP. BEFORE MAKING ANY CUTS IN THE CONTACT SANDY MANUEL(813)973 -3465 TO COORD, DELIV. GROUT. - X 71 I I 4 5 O *R 8 COLD -CUP DISPENSER (3) 4.375 "D 5.875 "D "TOMLINSON" MODEL #ELC -1002 " TOMLINSON" MODEL #ELC -1020 FIELD VERIFY EQUIPMENT BEFORE MAKING ANY CUTS IN THE COUNTERTOP. sls ® 12X35, PORCELONSA WALL TILE, BRUNI GRIS FNO CALL JULIO HERNANDEZ 305- 715 -7153 TIC 9 REAR/SIDE COUNTER 1 VARIES SEE LN CUSTOM FABRICATED STAINLESS STEEL ® „ /$"i7/ A. ,� © - r * 10 MENU BOARD VARIES CUSTOM FABRICATED LCD PANELS COUNTERS O O ■r OA* - (GR 1) 3/4" THICK GRANITE "BLACK GALAXY" INSTALLED PER MANUFACTURER'S RECOMENDATIONS R 11 CONDIMENT HOLDER 8 COOR0. WITH OWNER , 32 LI I� I _ I_ 1 :1 * 12 DRINK DISPENSER 1 CRATHCO 035 115V/60 HZ, B.5 AMPS CEILINGS is \ ' �\ ,f _ - 0 O 0 Q 11114 O 42 ' : _ i7 i�i [••C �, _,I JF R 16 GAS G RIDDLE /RANGE 1 34" W 39" D 36" H VULACAN #GH60T /45 MUST BE PROVIDED W/ LEGS,STAND AND CASTERS . MUST BE UNDER HOOD VENTING 200 F.F.M. FER SQ. FT. OF EQUIP. SURF. 3/4" GAS INLET IS LOCATED AT LEFT REAR. GAS PRESSURE MUST BE 6" W.C. FOR NATURAL OR 10" W.C. FOR PROPANE BTU /HOUR TOTAL = 150,000 BTUH PROVIDE DORMONT QUICK DISCONNECT SYS EM. ( ) SUSPENDED CEILING PANELS: 2'x4' VINYL CLAD GYPSUM ROCK, "USG", `SCP-1 > > ®�f UI GRID: CHICAGO METALIC: SERIES 830 ALUMINUM W/ WHITE FINISH #41 I 41„........11 44 O I J _ za (GB -1) GYPSUM BOARD, CEILING- 5/8" TYPE "X" PAINTED PER REFLECTED CEILING PLAN �1 I * R 18 GRILLRICAL 1 32 D l5" H TAYLOR COMPANY QS12 208 VOLT/ 60 HZ / 30 PROVIDED W/ L15 -30P 9.6 KW, 27 AMP \,.,- I ' MISC. _ r II h j $ / II * R 17 HEATLAMP STRIPE i CUSTOM HATCO OVERHEAD WARMER HEAT LAMP GLO -RAY® INFRARED FOODWARMER, HIGH WATTAGE, TUBULAR METAL HEATER ROD, SINGLE HEATER ROD HOUSING, ALUMINUM CONSTRUCTION, 1100 WATTS, 6 7 Mil PAINT METAL DOOR & FRAME ETC.: "SHERWIN WILLIAMS" CELU -TONE SATIN ( I ( I _ re • LUSTER ENAMEL; WHITE, USDA APPROVED. �� % B I A i�C R 24 HIGH VOLUME GAS FRYER 1 62" W 33" D 33" H ULTRAFRYER SYSTEM MODEL# B U /HR 4 360,000 BTU /HR 120V/60 HZ/ 10 8.5 AMP UNIT TO BE VENTED UNDER CANOPY W /MECH. EXHAUST SYS. 3/4" I.P.S. MANIFOLD AND GAS CONNECTION. PROVIDE "E 6R W C FOR NATUIRAL OR 11SW.CE OR PRO ANEURETO B C P -2 ) BENJAMIN MOORE RED (2000 -10) ---� -._.�, 44 G %In 16) �Q j . i MN BENJAMIN MOORE SOFT BEIGE (2156 -60) • ( P -4 ) BENJAMIN MOORE RACING ORANGE (2169 -10) B A I • I�i 8 N 25 SANDWICH PRESS ( OSCI) 2 16" W 23 -1/8" D 14 -3/8" H STAR MANUFACTURING INTERNATIONAL INC. MODEL #GR14SPTA 2 -SIDED GRILL, 120. V, 2300 WATTS, 19.2 AMPS 5 -20 NEMA CONFIGURATION - 12 ® STAINLESS STEEL. - O - •• R 26 EXH. HOOD 1 24 "H W /LIGHT FIXTURES SEE HOOD DRAWING LENGTH & WIDTH VARY, SEE PLAN AND HOOD SHOP DWGS. EXHAUST /SUPPLY DUCTS TO BE CUSTOM SIZED FOR- CONTROL OF SMOKE FROM WOK. I// EQUIPMEW PLAN ANSUL SYSTEM TANKS AND CONTROL PANEL i "ANSUL" PRE -ENG. LIQUID CHEMICAL FIRE SUPPRESSION SYS. W /FIXED NOZZELS. SYS. TO BE UL CLASSIFIED AND INSTALLED M H L BE CAPABLE NFPA #96 REQ. SYSTEM SHALL BE CAPABLE OF AUTOMATIC AND MECH. OPERATION W /AUTO SOLINOID GAS VALVE SHUT DOWN. ASSEMBLY, TESTING AND CERTIFICATION BY GEN. CONTR. INSTALL SYSTEM AS CLOSE TO CEILING AS POSSIBLE. MIN HGT. TO BOTT. OF UNIT TO BE 6' -6" AFF. NOTE: NOZZELS CHROME AND PIPING IN PUBLIC VIEW SHALL BE CHROME FINISHED, ELEC: FOR EMERGENCY SHUT OFF, CONNECT. CONTROL PANEL TO SOLINOID FOR SHUT DOWN OF GAS SUPPLY UPON ACTIVATION. PLUMB :CONNECT ANSUL TANKS TO HOOD W/ RED PAINTED PIPE. INSTALL GAS SOLINOID VALVE SIZED PER PIPE SIZE. NOTE: " " 1. ALL FINISHES TO BE MIN. CLASS C . 2. ALL MATERIALS USED FOR INTERIOR FINISHES AND TRIM SHALL BE CLASSIFIED IN ACCORDANCE WITH ASTM E84• SCALE: 1/4" = 1' -0" EXISTING CEILING * 23 HOLDING CABINET 1 26" W. 3 6" D 36" H ALTO SHAAM 125 v 1 ph, 16 amp. FILL VOIDS WITH U.L. #HW- S -0009 (1 -HR) SUPPORT WIRE * 29 ICE MAKER ICE BIN 1 CUBER 22" W 30-1/4" H BIN 30" W. 34" D 44" H. "MANITOWOC" #SN950 CUBER AIR COOLED: 208 - 230/60/1 15.0 AMPS 3 WIRE W /NEUTRAL FOR 115V B570 ALLOW 6" AIR CLEARANCE @BACK OF UNIT. ELEC : '208- 230V/60/1 - 7 AMPS SIMPLEX @ 80" AFF (3 WIRE WITH NEUTRAL FOR 115V) PROVIDE 6' CORD AND PLUG TO UNIT. PROVIDE 3/4" INDIRECT WASTE DRAINS FROM BIN & CUBER. 3/8" O.D. CONDENSATE AND 1/2" INDERECT WASTE FROM CONDENSER To FLOOR DRAIN. MAINFOLD AS REQUIRED. � � � ® ! �aaa��a���J���POPJ�� .��p���p�p�����pp". ��������������_ ��������������������������'��������� • X444 .•����...•4*.. :h..,k., :!: � :!���,���kit:��� *,��X:! a p y� p2 g._ ?lia ?2d EXISTING FLOOR CEILING & ' " RUNNER: 20 MSG (MIN.) GALV. STEEL 1 IN. HIGH, RETURN LEGS 3-5/8 IN. WIDE (MIN.) ATTACHED TO FLOOR AND CEILING WITH FASTENERS 24 IN. O.C. 100 GYPSUM 1 BRING INCONSISTENCIES BETWEEN FINISH MATERIAL NOTES, FINISHES PLAN, INTERIOR ELEVATIONS & DETAILS TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION PRIOR TO ORDERING MATERIALS OR BEGINNING INSTALLATION. 2' SUBCONTRACTORS MUST EXAMINE EACH INSTALLATION AREA FOR CONDITIONS INTERFERING WITH PROPER, TIMELY, OR. ACCEPTABLE COMPLETION OF THE WORK & SHALL NOTIFY THE GENERAL CONTRACTOR OF UNACCEPTABLE CONDITIONS REQUIRING ATTENTION BEFORE FINISH MATERIAL INSTALLATION. 3• DO NOT BEGIN FINISH MATERIAL INSTALLATION BEFORE UNACCEPTABLE CONDITIONS HAVE BEEN CORRECTED IN A MANNER ACCEPTABLE TO THE GEN. CONTRACTOR & ARCHITECT FOR THAT PORTION OF THE WORK. 4• PERFORMANCE OF THIS WORK BY THE INSTALLER INDICATES ACCEPTANCE OF ALL SUBSTRATE CONDITIONS & ASSUMPTION OF RESPONSIBILITY FOR COMPLIANCE WITH MATERIAL INSTALLATION QUALITY STANDARDS. EXISTING �I * ' I 3" S/S CHANNEL WELDED To HOOD BY MANUFACTURER DECK EXISTING SUSP. CLG . STAINLESS SEAL TO DECK - 100 JOINT TAPE FA COMPOUND * 32 3 -COMP. SINK 1 96 "W 30 -1/2 "D 40 -1 /2"H "EAGLE" MODEL #412- 18 -3 -18 R&L BOWL SIZE 24x18; PROVIDE W /" FISHER" - #3254 BACKSPLASH MOUNTED FAUCET PROVIDED W/1 -1/2" IPS BASKET TYPE WASTE. PROVIDE 1/2" In HOT &COL.D WATER CONNECTIONS. PROVIDE W/T&S FAUCET SPRAYER #T- 40/B1298V W /ADD ON FAUCET #B156ADF. STEEL TRIM - TIC 33 1 -COMP. SINK 0 38.5 "W 27 -1 /2"D 40 "H "EAGLE" MODEL #414- 16 -1 -18 R OR L BOWL SIZE 20X16 PROVIDED W/1 -1/2" IPS BASKET. TYPE WASTE. PROVIDE 1/2" IPS HOT & COLD WATER CONNECTIONS. WALLBOARD: 5/8 IN. THICK, TYPE X, 4 FT. WIDE, ATTACHED TO STEEL STUDS AND FLOOR * 34 MOP SINK 1 224 o FIAT 24z4. SEE PLUMBING * R 39 SANDWICH TOP REFRIG. 2 32.31" W 31.5" D 46' H DELFIELD 4432 mega top ref. 115/60/1 7.2 AMPS 1/5 HP AND CEILING TRACK WITH 1 IN. LONG, TYPES SELF - TAPPING STEEL SCREWS SPACED 8IN. O.C. ALONG EDGES OF BOARD AND 12 IN. O.C. IN THE THE BOARD. OINTS OF ORIENTED VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF THE ASSEMBLY. U.S. GYPSUM CO.-TYPE 'C' OR EQUAL. HOOD * 39A WORK TOP REFREGIRATOR 1 48" w, 30" D. Continental Refrigerator Model: SW48 WORKTOP COOLER 115/60/1 7.2 AMPS 1/5 HP '* R 39B WORK TOP FREEZER 1 48 -3/8" W 33 "DH TRUE 413E 115/60/1 5 AMPS 1/5 HP DRY OR PREMIXED JOINT COMPOUND, APPLIED IN TWO COATS TO JOINTS AND SCREW HEADS; PAPER AT HOOD 2 EQUIPMENT N�� * 40 WATER HEATER 1 SEE- PLUMBING 1. ALL EQUIPMENT AND SIGNAGE SHALL BE PURCHASED BY THE OWNER AND INSTALLED BY THE GENERAL CONTRACTOR. 2. FOOD SERVICE AND BEVERAGE DISPENSING EQUIPMENT SHALL COMPLY W/ NSF REQUIREMENTS AND REQUIREMENTS OF LOCAL HEALTH OFFICIALS HAVING JURISDICTION. 3. INSTALLATION AND CONNECTION OF ALL FOOD SERVICE EQUIPMENT IS TO BE PERFORMED BY THE GENERAL CONTRACTOR UNLESS OTHERWISE INDICATED. 4. SHELVING UNITS SHALL BE ASSEMBLED AND SET IN PLACE BY THE GENERAL CONTRACTOR. 5. FOOD SERVICE EQUIPMENT REQUIRING AN ELECTRICAL CONNECTION IS TO BE FURNISHED W/ CORD AND PLUG UNLESS OTHERWISE INDICATED. 6. VERIFY THE ELECTRICAL AND MECHANICAL REQUIREMENTS OF FOOD Q SERVICE EQUIPMENT PRIOR TO INSTALLATION. 7. SINKS SHALL BE PROVIDED W/ DRAIN TAILPIECES AND FITTINGS. THE GENERAL CONTRACTOR SHALL PROVIDE SHUT -OFF VALVES, SUPPLIES AND TRAPS NECESSARY TO CONNECT SUCH SINKS. 8. PROVIDE A SHUT -OFF VALVE AT HOT AND /OR COLD WATER SERVICE�� TO EACH PIECE OF EQUIPMENT REQUIRING WATER CONNECTION(S). 9. PROVIDER BACKFLOW E AT EACH PIECE OF EQUIPMENT REQUIRING WATER CONNECTIONS. ( NOT INCLUDING SINKS ) NOTE: TAPE, 2 IN WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVERALL JOINTS. AS AN ALTERNATE, NOMINAL 3/32 IN. SCALE: 3" = 1' -0" A-2 * 42 WALL SHELF 3 14 "D 74 "H "METRO" WALL UNIT SEE PLAN FOR WIDTH THICK GYPSUM VENEER I I TIC as SHELF UNIT (OSCI) 3 SEE PLAN "EAGLE" 4 -TIER COATED WIRE SHELVING CATALOG #1860Z W /P74 -C POSTS GEN. CONTR. SET SHELF HGTS. AS FOLLOWS: BOTTOM SHELF:6" A.F.F. /SECOND SHELF:24" A.F.F. THIRD SHELF:48" A.F.F. / FOURTH SHELF:72" A.F.F. PLASTER MAY BE APPLIED TO THE ENTIRE SURFACE OF CLASSIFIED VENEER BASEBOARD, JOINTS EXISTING STEEL STUDS: 3 5/8" IN. WIDE (MIN.) 1 -1/4 IN LEGS, 3/8 IN. RETURN, FORMED OF 25 (MIN.) MSG MIN: GALV STEEL MAX *46 R HAND SINK DROP IN (OSCI) 1 14 -1/2 "W 1e -1/2"D "EAGLE" - _ MODEL #HSA -10 -F PROVIDE 1/2" IPS HOT & COLD WATER CONNECTIONS REINFORCED. STUD SPACING 24 IN. O.C. - TILE I TILE OR IP * 46A HAND SINK WALL MOUNTED O NE EXISTING & NEW 1 10 "W 14 "D 10 "H "ADVANCE" MODEL #D1 -1 -10 PROVIDE 1/2" IPS HOT & COLD WATER CONNECTIONS - • IN FRP FINISH * 47A 2 DOOR FREEZER (OSCI) 1 52" 35" D. 83" H. TRAULSEN #G22010 115 /60 /1 NEMA L14 -20P PLUG 14.9 AMP 3/4 HP r FRP FINISH EXISTING EXIST.FLOOR & CEILING RUNNER: 20 MSG (MIN.) GALV. STEEL 1 IN. HIGH, RETURN LEGS 3-5/8 IN. WIDE (MIN.) ATTACHED TO FLOOR AND CEILING WITH FASTENERS 24 IN. O.C. * R 47B COOLER (OSCI) 1 5V L 35" D. 83" H. TRAULSEN #RHT232WUT -FHG 115/60/1 NEMA L14 -20P PLUG 10.4 AMP 1/2 HP ( N _ I N 48 SANDWICH TOP REFRIGERATOR (OSCI) 1 60 -3/8" W 30 -1/8" D 36 -3/4" H TRUE MODEL #TSSU- 60 -12, 12 PANS, 4 SHELVES, 15.5 CUBIC FEET, 1]3 HP, 110 VOLTS, 60 HZ, 1 PHASE, 7.8 AMPS, WITH OVERHEAD SHELVING 5 -15P NEMA CONFIGURATION _ 2„ 16 GA S/S ANGLE CORNER SLAB QTB 1 BASE SALES AND KITCHEN AREA, GUARD, SET IN PLACE W/ STR'L ADHESIVE & 16 GA.S /S END WALL CAP SILICONE ALL EDGES GUARD, SET IN PLACE W/ STR'L ADHESIVE & PLAN VIEW SILICONE ALL EDGES * 51 ELECT. PANELS (CSCI) 1 SEE ELECTRICAL DWG. IDEMOLS 3 ALL FIRE -WALL PENETRATIONS TO BE INSTALLED PER U.L. NUMBERS: WL 1001 WL 2002 WL 1002 WL 2003 WL 1003 WL 2004 WL 5001 WL 2005 WL 5002 ROOM NNISH sooDuto SCALE: 1 1/2" = 1' -0" A 2 -�. THE ABBREVIATIONS NOTED ON THE EQ. SCHEDULE: "O.S.C.1." STAND FOR 0= OWNER C= CONTRACTOR S= SUPPLIED I= INSTALLED AREA FLOOR WALLS CEILING BASE U.L. DESIGN NO U425 NONBEARING WALL RATING - 1 HR. ritip, @ DEMISING ALL 1 SCALE: 3/4" = 1' -0" A -2. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 3 2012 Cit y' Of Tukwila BUILDING DIVISION , D KITCHEN QUARRY TILE QT -1 WHITE CER. TILE T -4 WASHABLE VINYL FACED LAY -IN TILE LAP -1 QTB -1 � P G ACCESSORIES SC� A SURFACE MOUNTED SOAP DISPENSER BOBRICK #8 -87 SALES QUARRY TILE QT -1 CER. TILE SEE ELEV. PAINTED RED, _ QTB -1 . GB-1 c p -2 � B SURFACE MOUNTED PAPER TOWEL DISPENSER -" BOBRICK #B2621 a COOKING QUARRY TILE QT-1 STAINLES STEEL PANELS SEE ELEV. _ PAINTED SOFT BEIGE, QTB -i 7 -1 1-'12 GB -1 imp iPd13 DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: as owl SOUTHCENTER REVISIONS SPACE FC 633 SOUTHCENTER WA 98188 DAVID HIATT ARCHITECT 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL, 813.333.2717 FAX. 813.289.3332 RECEIVED JUL 20 2012 PERMIT CENTER EQUIPMENT PLAN, SCHED. DETAILS, FINISH SCHED. • SHEET NUMBER A-2 O F. 5 EXISTING "CHICKEN NOW" SIGN. PER CONTRACTOR. SIGN CONTRACTOR TO SUBMIT SHOP DRAWINGS TO L.L. FOR APPROVAL PENDANT LIGHT RELOCATE TO CENTER ON NEW SNEEZE GUARD EXISTING "CHICKEN NOW SIGN. PER CONTRACTOR. SIGN CONTRACTOR TO SUBMIT SHOP DRAWINGS TO L.L. FOR APPROVAL PENDANT LIGHT RELOCATE TO CENTER ON NEW SNEEZE GUARG EXISTING COUNTER TOP MATERIAL TO REMAIN EXISTING COUNTER TOP MATERIAL TO REMAIN REVIEWED FOR CODE COMPLIANCE APPROVED JUL 3 0 2012 EXISTING 6" BASE FLUSHED WITH TILE REMOVE EXISTING 1/4" TEMP. AND ART MURAL. RECONFIGURE THIS AREA FOR NEW STEAM TABLE AND COLD PANS. Menu Board: Provide shop drawings for menu and revised signage along with Graphic Content of Menu boards for LL approval N EW 1/4" TEMP. GLASS PANELS OVER GRAPHIC MURAL 1/4" TEMP. GLASS PANELS BACK PAINTED RED TO MATCH EXISTING RED COLOR NEW RECESSED PRE FAB. MENU BOARD BOX FLUSHED W /FACE OF GLASS EXISTING 1/4" BACK PAINTED TEMP. GLASS PANELS P -4 PAIN COLOR. ORANGE EXISTING 4X4 GLASS TILE HATCH AREA INDECATES EXISTING TO REMAIN EXISTING 'CHICKEN NOW'. SIGN TO REMAIN NEW 3 5/8 M.S. WITH 5/8" GYP. BD. BOTH SIDES FINISH PER NEM (4r1-0P OF COUNTER EXIST. LANDLORD 2' -10" NEUTRAL PIER LEASE LINE NEW 3 5/8 M.S. WITH 5/8" GYP. BD. BOTH SIDES FINISH PER EXISTING 1/4" TEMP. GLASS PANELS BACK PAINTED RED EXISTING C ' UNTER ECONFIGURE EXISTING COUNTER Design DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: L.i 0 W 0 Z 0 W. 13) = Z Lil 0 0 M CO CO REVISIONS AREVISED PER LANDLORD 1/23/00 WA 98188 4410 W. MELROSE AVENUE TAMPA, FLORIDA33629 TEL. 813.333.2717 FAX. 813.289.3332 RECEIVED JUL 2 0 2012 PERMIT CENTER STOREFRONT ELEVATIONTS AND SECTIONS SHEET NUMBER Alw3 O F. 5 NEW T 2 COVERED BY HOOD EXISTING ( T -2 ) EXISTING (T -2) NEW HAND SIN NEW OPEN QTB -1 ( T -2 11 ELWATION SCALE: 3/8" = 1' -0" OPEN TO KITCHEN S /STEEL PANELS OPEN S/S PANELS 0 HOOD ELOCATED S /STEEL PANELS O O 24 24 �u 1 W L (QTB -1) 01 O O 24 000000 u I VA. ,.u.. Menu Board: Provide shop drawings for menu and revised signage along with Graphic Content cf Menu boards for LL approval 1' -3" 1' -3 3/4" QTB 1 BASE, TYP. O N SNEEZE GUARD LIGHT 1/2" TEMP GLASS SILICONE BUTT -JOINT (GR-1) WOOD BLOCKING (GR-1) 3/4" PLYWOOD LIGHT COVE SEE LIGHTING SCHEDULE CONT. STAINLESS STEEL ANGLE FOR SUPPORT STAINLESS STEEL BASE PT 2X SUPPORTS COUNTER s SCALE: 1 -1/2" = 1' -0" EXISTING 8" GYP.BD. 6" METAL STUDS BLOCKING LCD SCREEN BRACKET MOUNTED ON PLYWOOD. 5/8" GYP. BD. TYP. FINISH TO MATCH ADJACENT. NOTE 0 N S/S J CHANNEL FOR GLASS SUPPORT 1/4" BACK PAINTED TEMP GLASS 1 -1/2" S/S ANGLE AROUND OPENING 3/4" GAP AROUND MENU BOX MENU BOX SHALL COME WITH A REMOVABLE BLACK METAL FRAME TO HIDE GAP AND TO \ FLUSH WITH FACE OF GLASS. PROVIDE ACCESS TO ALL REQUIRED WIRING, COORDINATE WITH OWNER FOR LOCATION. r m i0 M 1) pox D SCALE: 1 -1/2" = 1' -0" 3/4" F.R.T. PLYWOOD OVER GYP. BD. PAINT PLYWOOD BLACK. RECESSED MENU BOX 1 -1/2" S/S ANGLE AROUND OPENING 1/4" BACK PAINTED TEMP GLASS 1 -1/2" S/S ANGLE AROUND OPENING REVIEWED FOR CODE COMPLIANCE APPROVED JUL 3 0 2012 City of Tukwila BUILDING DIVISION /est eid Design Review 0' yppro:i.Ki • ., ppr47' N k i :• ft uurr; 1t" fir vi,4•91.h3+rf)g-4Trar+Y.-a tr*-1 : (;:s)4, "yf.y ik ∎ZeJ.}. 4 {Y01."..:21.3 y 1Y4J, 1 .. `J i.T111 :47: Fri' 1"4 blur(; b O ?t...:d:`.."4.1. CS".; : #; re a;sr .t ;:rr I;r zne,-T.'yeg s ° *`t P10710O r n rt Aa, 'a;a►'!. C u' .irl! ti.�:. 4 •z�]S Sn' .'� �� A j r.11.1 Y1'kt 211 - Sy9 Iffr to '.u1s:!;It7! i!a,ttt..*'. 7 -11 -12 L 1 DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: SOUTHCENTER SPACE FC 1 1 SOUTHCENTER M WA 98188 1— Q REVISIONS LAVID H CHI EC 4410 W. MELROSE AVENUE TAMPA, FLORIDA33629 TEL. 813.333.2717 FAX. 813.289.3332 RECEIVED JUL 20 2012 PERMIT CENTER SECTIONS AND DETAILS SHEET NUMBER 7A3=4 0F5 . r. L• y. VERIFY SIZE WITH EQUIP. SUPPLIER COLD /HOT WELLS SEE EQUIPMENT PLAN WHITE PLASTIC LAMINATE PI TO EXISTING FLOOR SINK JJ Ce >ppCp QTB 1 BASE, TYP. O N SNEEZE GUARD LIGHT 1/2" TEMP GLASS SILICONE BUTT -JOINT (GR-1) WOOD BLOCKING (GR-1) 3/4" PLYWOOD LIGHT COVE SEE LIGHTING SCHEDULE CONT. STAINLESS STEEL ANGLE FOR SUPPORT STAINLESS STEEL BASE PT 2X SUPPORTS COUNTER s SCALE: 1 -1/2" = 1' -0" EXISTING 8" GYP.BD. 6" METAL STUDS BLOCKING LCD SCREEN BRACKET MOUNTED ON PLYWOOD. 5/8" GYP. BD. TYP. FINISH TO MATCH ADJACENT. NOTE 0 N S/S J CHANNEL FOR GLASS SUPPORT 1/4" BACK PAINTED TEMP GLASS 1 -1/2" S/S ANGLE AROUND OPENING 3/4" GAP AROUND MENU BOX MENU BOX SHALL COME WITH A REMOVABLE BLACK METAL FRAME TO HIDE GAP AND TO \ FLUSH WITH FACE OF GLASS. PROVIDE ACCESS TO ALL REQUIRED WIRING, COORDINATE WITH OWNER FOR LOCATION. r m i0 M 1) pox D SCALE: 1 -1/2" = 1' -0" 3/4" F.R.T. PLYWOOD OVER GYP. BD. PAINT PLYWOOD BLACK. RECESSED MENU BOX 1 -1/2" S/S ANGLE AROUND OPENING 1/4" BACK PAINTED TEMP GLASS 1 -1/2" S/S ANGLE AROUND OPENING REVIEWED FOR CODE COMPLIANCE APPROVED JUL 3 0 2012 City of Tukwila BUILDING DIVISION /est eid Design Review 0' yppro:i.Ki • ., ppr47' N k i :• ft uurr; 1t" fir vi,4•91.h3+rf)g-4Trar+Y.-a tr*-1 : (;:s)4, "yf.y ik ∎ZeJ.}. 4 {Y01."..:21.3 y 1Y4J, 1 .. `J i.T111 :47: Fri' 1"4 blur(; b O ?t...:d:`.."4.1. CS".; : #; re a;sr .t ;:rr I;r zne,-T.'yeg s ° *`t P10710O r n rt Aa, 'a;a►'!. C u' .irl! ti.�:. 4 •z�]S Sn' .'� �� A j r.11.1 Y1'kt 211 - Sy9 Iffr to '.u1s:!;It7! i!a,ttt..*'. 7 -11 -12 L 1 DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: SOUTHCENTER SPACE FC 1 1 SOUTHCENTER M WA 98188 1— Q REVISIONS LAVID H CHI EC 4410 W. MELROSE AVENUE TAMPA, FLORIDA33629 TEL. 813.333.2717 FAX. 813.289.3332 RECEIVED JUL 20 2012 PERMIT CENTER SECTIONS AND DETAILS SHEET NUMBER 7A3=4 0F5 INSTALL 120V 25 AMP GFI ELECT 0 FOR SAND. PRESS INSTALL 120V GFI ELECT OUTLET FOR SNEEZE GUARD LIGHT INSTALL 120V 20 AMP GFI ELECT OUTLET FOR COLD WELLS. INSTALL 208V 20 AMP GFI ELECT OUTLET FOR HOT WELLS EXISTING ELECTRICAL SYSTEM (PANELS, XFRMR., RECEPTACLES, L REMAIN. RECONNECT NEW EQUIPMENT TO SPARE CIRCUITS ON PANEL. VERIFY THE ELECTRICAL RATING FOR ALL NEW REPLACED ECG �GHT FIXTURES, ETC.) TO EXISTING LOW VOLTAGE UIPMENT. HYAC NOTE: EXISTING MOP SINK EXISTING WATER HEATER EXISTING ICE /IACHINE I� XISTING HAND SINK NEW .COLD WELLS NEW HOT WELLS EXISTING SODA MCHINE EXISTING FLOOR SINK, NEW ,HOT WELLS AND COLD WELLS TO BE INDIRECTLY DRAINED TO EXISTING FLOOR SINK EXISTING 3 COMP SINK C REMAIN EXIST PREP SINK REMAIN !, sal NEW HAND SINK. INSTALL 1/2" CO WATER AND CONNECT TO EXISTING COLD AND H WATER AT THIS LOCATION. PROVIDE AND INSTALL 1 -1/2" IDIRECT DRAIN LINE TO FLOOR SINK UNDER PREP SINK. EXISTING / MODIFIED PLU NOTE: EXTEND GAS LINE TO RELOCATED COOKING EQUIPMENT AND RECONNECT ACCORDINGLY EXISTING SODA MCHINE RELOCATED DROP IN HAND SINK. INSTALL 1/2" COLD AND HOT WATER AND CONNECT TO EXISTING COLD AND HOT WATER AT THIS LOCATION. PROVIDE AND INSTALL 1 -1/2" IDIRECT DRAIN LINE TO FLOOR K UNDER PREP SINK. ING PLAN UNLESS NOTED OTHERWISE ON PLANS, ALL PLUMBING (FLOOR DRAIN, FLOOR SINKS, VENTS, WASTE LINES, C/W LINES, H/W LINES, WATER HEATER, ETC.) ARE EXISTING TO REMAIN. CONTRACTOR TO VERIFY THE CONDITION OF ALL OF THE ABOVE AND REPORT FINDINGS TO OWNER AND ARCHITECT. RECONNECT RELOCATED EQUIPMENT AND PLUMBING FIXTURES TO EXISTING PLUMBING AND WATER SYSTEMS. EXISTING HVAC SYSTEM TO REMAIN MECHANICAL CONTRACTOR IS TO VERIFY CONDITION OF EXISTING HVAC UNIT TO BE REUSED AND VERIFY ALL COMPONENTS (I. E. FAN MOTORS, COMPRESSOR, HEATING COILS, THERMOSTATS AND CONTROL DEVICES, ETC.), PERFORM ALL NECESSARY TESTS TO ASCERTAIN SYSTEM IS IN GOOD WORKING ORDER AND INSURE UPON HIS INSPECTION THAT UNIT AND ALL COMPONENTS WILL BE WARRANTED FOR A MINIMUM OF 90 DAYS FROM DATE OF CERTIFICATE OF OCCUPANCY OR WHEN STORE OPENS, WHICHEVER IS LATER. MECHANICAL CONTRACTOR IS TO PROVIDE A WRITTEN REPORT OF ALL TESTS PERFORMED, ALONG WITH HIS RECOMMENDATIONS ON THE EQUIPMENT TO OWNER CORPORATION. MECHANICAL CONTRACTOR SHALL COORDINATE WITH OWNER AND RELOCATE EXISTING EXHAUST HOOD TO LOCATION SHOWN ON PLAN. RECONNECT ALL EXHAUST / MAKEUP AIR DUCT WORK TO EXISTING DUCT. ALL WORK SHALL COMPLY WITH ALL CODES AND LANDLORD REQUIREMENT. NOTE: ALL DUCT WRAP SHALL BE SEALED WITH GLASS INSTALL PER MANUFACTURES PRODUCT LITERATURE. "PRODUCT DATA REVIEWED FOR CODE COMPLIANCE. APPROVED JUL 3 ,0 2012 City of Tukwila BUILDING DIVISION 3" MINIMUM OVERLAP • (TYP =.LONGITUDINAL OR TRANSVERSE JOINTS) 3M FIRE BARRIER DUCT WRAP 615+ BLANKET FOR GREASE DUCT ENCLOSURE ASSEMBLIES 2 LAYER = 2 HOUR ESR #1255 2 HOUR RATED ASSEMBLY. 16 GA. `GREASE DUCT NOTE: PROVIDE SIMILAR CONSTRUCTION AROUND HOOD CONT. WELD FIELD APPLIED OR FACTORY BUILT GREASE DUCT ENCLOSURE SHALL BE INSTALLED PER THE LATEST MANUFACTURER'S INSTALLATION INSTRUCTIONS AND IN COMPLIANCE WITH TERMS OF ITS LISTING. ALL END CUTS OR CUTS IN THE FOIL JACKET OF FIELD APPLIED GREASE DUCT ENCLOSURE SHALL BE SEALED PER THE MANUFACTURER'S RECOMMENDATIONS. ALL INSTALLATIONS SHALL BE COMPLETELY ACCESSIBLE FOR VISUAL INSPECTION. AT TIME OF INSPECTION, THE FIELD APPLIED OR FACTORY BUILT GREASE DUCT ENCLOSURE INSTALLATION INSTRUCTIONS SHALL BE MADE AVAILABLE AT THE JOB SITE. . DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: u. w N U 0_ I..L Q I v) Z ww ct UU w. 4) 2 Z 1.4 U V ! CO D 0 2 V) co Ci REVISIONS WA 98188 DAVID HIATT ARCHITECT 44io: W MELROSE AVENUE TAMPA, FLORIDA 33629 TEL.' 813.333.2717 FAX. 81:3.2893332 RECEIVED JUL 20 2012 PERMIT CENTER MECH., ELECT. & PLUMBING MODIFICATIONS SHEET NUMBER MEP-1