Loading...
HomeMy WebLinkAboutPermit M12-117 - SOUND TRANSIT - SOUNDER STATIONSOUND TRANSIT SOUNDER STATION 7301 LONGACRES WY M12 -117 Parcel No.: Address: Project Name: City o"i'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206. 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT 2423049029 7301 LONGACRES WY TUKW SOUND TRANSIT SOUNDER STATION Permit Number: M12 -117 Issue Date: 09/23/2013 Permit Expires On: 03/22/2014 Owner: Name: Address: Contact Person: Name: Address: Email: UNION PACIFIC RAILROAD CO PROPERTY TAX , 1400 DOUGLAS STOP 1640 68179 KYM WILLIAMS 401 S JACKSON ST , SEATTLE WA 98104 KYM. WILLIAMS @SOUNDTRANSIT.ORG Contractor: Name: UNIVERSITY MECH CONTR INC Address: 11611 49TH PL W , MUKILTEO WA 98275 -4255 Contractor License No: UNIVMC *343N9 Phone: 206 - 398 -5156 Phone: 206 - 364 -9900 Expiration Date: 10/03/2014 DESCRIPTION OF WORK: FIRE SPRINKLING, PLUMBING AND HVAC SYSTEMS WILL BE PROVIDED FOR THE ANCILLARY BUILDING. NON - POTABLE WATER WILL BE PROVIDED TO PLATFORMS. Value of Mechanical: 200,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read an governing this work will be complie Fees Collected: $2,334.56 International Mechanical Code Edition: 2009 Date: exa fined this permit and know the same to be true and correct. All provisions of law and ordinances wit , whether specified herein or not. The granting of this permit does not pre me to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: ��aYi Date: al /73/ZO/ 3 Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12-117 Printed: 09 -23 -2013 • • PERMIT CONDITIONS Permit No. M12 -117 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code'or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -117 Printed: 09 -23 -2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. `' D d= 1 7 Project No. 1 1 Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION King Co Assessor's Tax No.: 2523049087, 0005800020 Site Address: 7301 South Longacres Way Suite Number: Floor: Tenant Name: Sound Transit PROPERTY OWNER Name: Kym Williams Address: 625 Union Station Name: Sound Transit Phone: (206) 398 -5156 Fax: (206) 398 -5228 Email: kym.williams @soundtransit.orga Address: 401 S. Jackson City: Seattle State: WA Zip: 98104 CONTACT PERSON — person receiving all project communication Name: Kym Williams Address: 625 Union Station City: Seattle State: WA Zip: 98104 Phone: (206) 398 -5156 Fax: (206) 398 -5228 Email: kym.williams @soundtransit.orga New Tenant: ❑ Yes 0 ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Fire Sprinkling, Plumbing and HVAC systems will be provided for the Ancillary Building. Non - potable water will be provided to Platforms. 200,000 Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric m Gas ❑ Other: H:WpplicationsWorna- Applications On Line 12011 Applications\Mechamcal Perrtut Application Revised 8.9 -1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor fumace 1 Suspended/wall /floor mounted heater 4 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 1 Unit Type Qty Air handling unit >10,000 cfn Evaporator cooler 1 Ventilation fan connected to single duct 3 Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat 1 Wood/gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT ED AGENT: Signatur Date: D p4d /Z-- Print Name: Ky ' Williams Day Telephone: (206) 398 -5156 Mailing Address: 625 Union Station Seattle WA 98104 City State Zip H:\Applications\Fornts- Applications On Line \2011 ApplicationsUNechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 2 of 2 Cit•of Tukwilar • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukw ila. wa. us SET RECEIPT RECEIPT NO: R13 -00822 Initials: WER Payment Date: 02/15/2013 User ID: 1655 Total Payment: 236,452.44 Payee: SOUND TRANIST SET ID: 0215 SET NAME: SOUND TRANSIT SET TRANSACTIONS: Set Member Amount D12 -272 223,072.45 EL12 -0777 11,167.15 M12 -117 1,867.65 PG12 -160 345.19 TOTAL: 2-23,072.45 TRANSACTION LIST: Type Method Description Amount Payment Check 00107206 236,452.44 TOTAL: 236,452.44 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES CASCADE WATER ALLIANCE ELECTRICAL PERMIT - NONR FLOOD ZONE CONTROL MECHANICAL - NONRES PLAN CHECK - NONRES PLAN CHECK - WATER METER PLUMBING - NONRES PW LAND ALT PERMIT FEE PW PERMIT /INSPECTION FEE PW PLAN REVIEW STATE BUILDING SURCHARGE WATER CONNECTION WATER INSPECTION FEE WATER INSTALLATION (DEP) T.7 7% Tr, T] T1 31.1 n'KT TJ T7L+ 000.322.100 640.237.500 000.322.101 00.0 000.322.400 000.322.102 00.0 000.345.830 000.345.830 000.322.103 00.0 000.342.400 000.342.400 000.345.830 640.237.114 401.379.002 401.342.400 401.245.100 A#1 '3 n"I 'Inc 27,561.95 84,070.00 11,167.15 50.00 1,867.65 69.04 30.00 276.15 721.00 86,895.00 17,895.00 4.50 685.00 45.00 4,965.00 1 c n n 11 City o?Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 2423049029 Permit Number: M12 -117 Address: 7301 LONGACRES WY TUKW Status: PENDING Suite No: Applied Date: 08/16/2012 Applicant: SOUND TRANSIT SOUNDER STATION Issue Date: Receipt No.: R12 -02387 Payment Amount: $466.91 Initials: WER Payment Date: 08/17/2012 10:03 AM User ID: 1655 Balance: $1,867.65 Payee: SOUND TRANSIT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 103180 466.91 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 466.91 Total: $466.91 doc: Receipt -06 Printed: 08 -17 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. /j CITY OF TUKWILA BUILDING DIVISION �� 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: , 5o",tc 1 / 6.-AS T" Type ofInspection: • l � v fJIA.n Is i\J AL Address: 1361 � i>Gle' Date Called: P. Pei Special Instructions: I Date Wanted: 22 f ff a.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: n,9fl�4, (c }e • Inspec Date:t Z - j4 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit M12'/ i 7 INSPECTION NO PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C- 6300 Southcenter Blvd., #100, Tukwila.,WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project- - ' ---- Dov,AD / /Gy4 I Type of In pection: ____ Ae_ r� &- . Ii( - -3`i Address: t n Gr Date Called: Special Instructions: f Date Wanted tU / W ./ f r ..a.m.. p.m. Requester: I Phone No: 2Approved per applicable codes. Corrections required prior to approval. COMMENTS: o I �. t Inspec'or. ouq-A Dater / f / n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. aar. r _.fzr INSPECTION RECORD Retain a copy with permit N►i Z� l l7 INSPECTION NO. PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Projec ., �..�. �., a u., D .. (/'e.A-S , Type of Inspection: ? . P. Svc S . Address: —1 36 1 Lt;A.4At-7-e- 5 Date Called: Special Instructions: f Date Wanted . A ,: 4 p.m. Requester: . . Phone No:. Approved per applicable codes:. Corrections required prior to approval. COMMENTS: Date z. -1.4 n REINSPECTION FEE REQUIRED. Prior to next inspection fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 YMIZ -1 i'7 Pr ect: i „c OLt /..)(k t r FI' r f Type..of Inspection: ' mci U1- Addres : .1 -3©( L b-WO ACrr Date Called: (A) Pt Special Instructions: Date Wa to [� — a— iii ,�-� 1��m. p.m. Request : Phone No: 131Approved per applicable codes. Corrections required prior to approval. COMMENTS: D % 7 NSPECTION FEE REQU FED. Prior to next inspection. fee must be paid at 6300 Southcenter Bldd.. Suite 100: Call to schedule reinspection. INSPECTION RECORD Retain copy with permit INSPECTION NO PERMIT NO.. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila.•WA 98188 (206) 43.1 -3670 Permit Inspection Request Line (206) 431 -2451. • f E-11 ri Pro t: ------ ;--- > 0 Jr\,0 " 1 r , (. Typeppf, Inspection: 0. JVl 2L , 1-49•J C-/ —` .JV Address: "730 ( (tu – t Date. Called: Special Instructions:.. - Date Wanted a.m. 1 Requester:( i i/'E-1 1-e. y P. o e No: �... I -- A, 5 3� (- --s483 ts Approved per applicable codes. 1__.J Corrections required prior to approval. COMMENTS: i "got: :r !'J E Date: n REINSPECTION FEE R`QUIRED. Prior next inspection: fee must be paid. at 6300 Southcenter Blvd.; Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451. M�2- 10 Project:: :. Typ of Inspection: �. ,S a l'A! 1 r� AS.' Address: , - t i - ailed: ' OU ' Special Instructions: / Date Wanted: 1—V? -14 a.m. ■per Requester: Phone No: Approved per applicable-codes. Corrections required prior to approval. COMMENTS: co X D _t Dat -./V1 - 1,4 I REINSPECTION. FEE REQ !RED. Prior to next inspection. fee must be paid at :6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. . 1 September 9, 2013 Kym Williams Sound Transit 401 S Jackson St Seattle, WA 98104 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Request for Reactivation Permit Numbers M12 -117, PG12 -160 & EL12 -0777 Sound Transit Sounder Station — 7301 Longacres Wy Dear Mr. Williams, This letter is in response to your written request for reactivation of Permit Numbers M12 -117, PG12 -160 and EL12 -0777. The Building Official has reviewed your letter and considered your request to reactivate the above referenced permits. It has been determined that the City of Tukwila Building Division will be reactivating your permit applications an additional 90 days from today's date, through December 9, 2013. Once issued, a new 180 day period will start before expiration. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician File: Permit No. M12 -117, PG12 -160 & EL12 -0777 W :IPermit CenterlExtension LetterslPermits120121EL12 -0777 Permit Reactivation.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665 Bill Rambo From: Sent: To: Cc: Subject: Importance: Hi Bob— Williams, Kym <kym.williams @soundtransit.org> Friday, September 06, 2013 4:51 PM Bob Benedicto O'Hare, Jon; Bill Rambo Permit Renewals Tukwila Commuter Rail Station High Thank you so much for returning my phone message. Per your request here is my email to you asking formally for renewal /extension of trades permits M12 -117, PG12 -160, and EL12 -0777. Additionally, it may also be that the construction permit D12 -272 is expired as well as most of these permits were sent renewals simultaneously. If not too much of a trouble I request that this permit too be renewed consistent with the rest. Thank you again for your time. If any questions, do not hesitate to contact me. Have a great weekend. Kym Williams Assistant Permit Administrator Sound Transit Dept of Engineering and Construction Management P: 206 398 -5156 C: 206 473 -0910 Kvm.williams @soundtransit.org OKI Nit) cetatijv,kat �t arka.o+^a.Q 90 dcLe, /cj/2cf3 1 t>\T-ek (3 RECEIVED CITY OF TUKWILA SEP 0 6 2013 PERMIT CENTER 04 -02 -2013 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director KYM WILLIAMS 401 S JACKSON ST SEATTLE WA 98104 RE: Permit Application No. M12 -117 SOUND TRANSIT SOUNDER STATION 7301 LONGACRES WY TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 08/16/2012, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 05/13/2013. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M12-117 6300 Southcenter Boulevard, Suite # 100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 -431 -3665 4 January 29, 2013 City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Jon O'Hare Sound Transit 401 S Jackson Street Seattle, WA 98104 -2826 RE: Request for Extensions Permit Numbers D12 -272, EL12 -0777, M12 -117, and PG12 -160 Sound Transit Sounder Station — 7301 Longacres Wy Dear Mr. O'Hare, This letter is in response to your written request for an extension to Permit Numbers D12 -272, EL12- 0777, M12 -117, and PG12 -160. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permits an additional 180 days from the date of expiration, through May 13, 2013. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, AA.ev\ shall ician File: Permit No. D12 -272, ELI2 -0777, M12 -117, & PG12 -160 W:IPermit CenterlExtension LetterslPermits120121D12 -272 Permit Extension.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665 • • SOUNDTRANSIT January 18th, 2013 Jack Pace Director of Community Development Department of Community Development City of Tukwila 6300 Southcenter Boulevard, Suite # 100 Tukwila, WA 98188 Permit Extension Request for Department of Community Development Permits M12- 117, EL 12 -0777, D 12 -272, and Pit -1^ .rAtp "E.,7 G la b aFPROLMI7 Dear Mr. Pace, 4 /Zeta Pursuant to IBC, IMC, UPC, and NEC, Sound Transit respectfully requests 90 day extensions for the following DCD permits: —r - 1 . Building Permit DI 2-272 (Sounder Station) FIRE , I5 pity p lac ) 2. Mechanical Permit M12- 117AC'PRoOED 4LJ(OruRt4 DW&) 3. Electrical Permit EL12- 07774C'Ptgovap 4. Plumbing/Gas Permit~ tp 0 d hPieoJeGG7 All above permits are scheduled to expire on 2/12/2013. Design changes and funding have delayed us in getting these permits issued. The permit sets have been resubmitted for review and we are working diligently on getting these permits issued and work underway. These permits are critical to the essential forward progress of building the new sounder station for our customers. If you have any questions regarding this request, please contact me immediately at the number listed below. Sincerely O'Hare Permits Administrator (206) 903 -7368 t 118-La -r v &t)\ (r C�7s`o U ?.ABED L ZT n� t - - AmooNT, oF QTY OF Tt>'x WIU+. 1JAN 222U13 PERMIT CENTER o,K, 40 €44l ro -06 /2/Zol3 Central Puget Sound Regional Transit Authority • Union Station 401 5. Jackson St., Seattle WA 98104 -2826 • 206 - 398 -5000 • 1- 800 - 201 -4900 • www.soundtransit.org atM • PcCarthy Pierce County °Executive` ;VICE CHAIRS -`Juba Patterson • ing County Councilniember= Aaron Reardon nohoniish County Executive :BOARDMEMBERS Claudia Balducci Bellevue Coiincilnieniber Fred Butler Issaquah Deputy Council President l RiclardConlin Seattle Couincilniember -.:Dow Constantine'' ing,County Executive Dave Earling Edmonds Mayor Dave eEnslow;;�. _`Sumner Mayor. 'Paula J. Hammond P.E.' • Washington State Secretary of :-.Transportation tw _ ax _ John Marchione j" ;Redmond Maya -• Joe McDermott King'Coditif Councalmentber Mike McGinn Seattle Mayon Mary Moss kewood:Councdmembei • 'Larry Phillips . • King'County Counctlmember PauhRoberts verett Councilniember "a. MarilynStrickland Tacoma -Mayor tt- eter•von Reichbauer, ..` ing-County Councilniember • Qxc " 0C- 01 -02 -2013 KYM WILLIAMS 625 UNION STATION SEATTLE WA 98104 • Jim. -Hagg e r to n,. ; Mayo r epartment of Cornmurnty Development JackPaee, Director RE: Permit Application No. M12 -117 SOUND TRANSIT SOUNDER STATION 7301 LONGACRES WY TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 08/16/2012, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 02/12/2013. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M12-117 6300 Southcenter Boulevard, 'SA* #1 by.. Tukw la, Washington 98188 • Phone 206 -431 3670 • Fax 206--01-3W FILE COPY Permit No., Tukwila Sounder Station: Mechanical Construction Permit Application Contents: • City of Tukwila Mechanical Permit Application Form • Washington State Energy Code Compliance Forms: o Envelope Summary (ENV -SUM) o Envelope UA Calculations (ENV -UA) o SHGC Calculation (ENV -SHGC) o Building Permit Plans Checklist (ENV -CHK) o Mechanical Summary (MECH -SUM) o Mechanical Permit Plans Checklist (MECH -CHK) o Interior Lighting Summary (LTG -INT) o Exterior Lighting Summary (LTG -EXT) 90% Permit Drawings (Mechanical Sheets) under separate cover Consulting Engineers 1 601 Fifth Avenue, Suite 1600 Seattle, WA 98101 (206) 622 -5822 KPFF Project No. 111026 July 6, 2012 tlIl117 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 12 2012 City ofTukrri►lle BUILDING DIVISION RECEIVED AUG 16 2012 PI+RM1T CENTER CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION King Co Assessor's Tax No.: 2523049087, 0005800020 Site Address: 7301 South Longacres Way Suite Number: Sound Transit Tenant Name: PROPERTY OWNER - Address: 625 Union Station Name: Sound Transit Phone: (206) 398 -5156 Fax: (206) 398 -5228 Email: kym.williams @soundtransit.orga Address: 401 S. Jackson State: City: Seattle State: WA Zip: 98104 CONTACT PERSON — person receiving all project communication Name: Kym Williams Address: 625 Union Station City: Seattle State: WA Zip: 98104 Phone: (206) 398 -5156 Fax: (206) 398 -5228 Email: kym.williams @soundtransit.orga Floor: New Tenant: ❑ Yes m .. No MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: • Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Fire Sprinkling, Plumbing and HVAC systems will be provided for the Ancillary Building. Non - potable water will be provided to Platforms. 200,000 Use: Residential: New ❑ Commercial: New Replacement Replacement Fuel Type: Electric VI Gas ❑ Other: H:\Applications \Forms- Applications On Line \20I I Applications\vIcchanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace 1 Suspended/wall /floor mounted heater 4 Appliance vent Repair or addition to headrefrig/cooling system Air handling unit <10,000 cfm 1 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler 1 Ventilation fan connected to single duct 3 Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat 1 Wood/gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp/ 1,000,000. btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print Name: Kym Williams Day Telephone: (206) 398 -5156 Mailing Address: 625 Union Station Seattle WA 98104 City H:Wpplicat ions \Forms-Applications On Line \201 I Applications\Mechanical Permit Application Revised 8 -9 -1 I.docx Revised: August 2011 bh State Zip Page 2 of 2 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Envelope UA Calculations Zone 1 Non - Residential 20.9 Washington State Energy Code Compliance Forms for Nonresidential and M ENV -UA Project Address Sound Transit Tukwila Station Date 06/15/2012 Occupancy Group O Nonresidential 0 Multifamily residential Clear For Building Department Use Climate Zone ® Zone 1 0 Zone 2 Fenestration Area as % gross exterior wall area 6.5% Max. Target: 40.0% Notes: 1: If fenestration area exceeds maximum allowed, then calculate adjusted areas on Target Area Adjustment sheet on the backside of the ENV -SHGC form. 2: U- factors shall come from chapter 10 or calculated per 1332. See the ENV -CHK worksheet for example of how to complete the rows on this form. Building Component Provide assembly ID & page /plan # for each bldg. element Proposed UA U- factor x Area (A) = UA (U x A' Target UA . U- factor x Area (A) = UA (U x A) w $ o R= 30 ID: RA -1 TK- A10.15 R= ID: R= . ID: 0.030 869 26.1 0.034 869 J 29.5 Above Deck Insulation U- 0.034. v T S R= ID: R= ID: R= ID: 0.031 Metal Building U -0:031 w O R= ID: R= ID: R= ID: 0.027 Single raft attic, other ,0 -0.027 Opaque Walls - Above IMetal Frm R= ID: R= ID: R= ID: R= ID: 0.064 1 -. I Steel frame /metal bldg U =0:064 .. r_, 'N o R =19 , ID: WA -1 TK- A10.15 R= ID: R= ID: R= ID: 0.038 1416 53.8 0.057 I 1416 I 80.7 Wood ,Frame, other U- 0.057' y 2 i R= ID: R= ID: R= ID: R= ID: Proposed assembly U- factor from Tables 10 -5 thru 10 -5B 0.150 I I Mass Wall U-0 :150 • Below R= ID: R= ID: R= ID: Proposed assembly U- factor from Tables 10 -5 thru 10 -5B. Do NOT use Table 10 -1. 0.150 1 I Assumed to•be Mass' Wall 0;0.150 - N a $ 0 U= 0.6 ID: Doors TK- A10.11 U= ID: U= ID: 0.600 202 121.3 0.60 I 202 121.3 All Doors U-0.60 ' E $ LL R= ID: R= ID: R= ID: 0.029.1 1 Floors U -0:029 F- factor x Perimeter = UA(U x AZ F- factor x Perimeter = UA (U x A) R =10 ID: Floor TK- A10,15 R= ID: R= ID: 0.540 172 92.9 r 0.540 I 172 I 92.9 Slab -On -Grade U= 0:540 1 Heated R= ID: R= ID: Proposed assembly F- factors can use the unheated values in 1 iAnti walls maahnn Tahla 1'2 -1 1-nntnnic 1 .... tie ....i......4 Table 10 -2 0.360 1 Heated Slab-On-Grade U= 0:360 dith U- -v 1 e f 15 rat FierThan Table 16$b weiues laris must early state loo note requirements. Page 1 Subtotal Area UA 2659 294 Area UA I2659 324 I L -- �•• �• «� L_1 yy uue L.vrrrpnance t-orms tor Nonresidential and Multifamily Zone 1 Non - Residential ENV -UA Envelope UA, continued. Project Address Sound Transit Tukwila Station Fenestration Area as % gross exterior wall area Date 06/15/2012 6.5% Max. Target: 40 .0% Notes: 1: If fenestration area exceeds maximum allowed, then calculate adjusted areas on Target Area Adjustment sheet on the backside of the ENV -SHGC form. 2: Provide NFRC or Table 10 -6 U- factor (See Section 1312.1) for fenestration assemby (combined frame and glazing performance). See the ENV -CHK worksheet for example of how to complete the rows on this form. For Building Department Use Building Component Provide assembly ID & page /plan # for each bldg. element Vertical Fenestration E u_ m U= 0.4 ID: Windows TK- A10.13 U= ID: U= ID: U= ID: Proposed UA U- factor x Area (A) = UA 0.40 112 Target UA U x A� U- factor x Area (A) = UA (U x A) 44.8 0.40 112 44.8 Metal Frame U-0.40 2 0 0 z Mtl entrance U 0 z U U= ID: U= ID: U= ID: U= ID: U= ID: U= ID: U= ID: U= ID: U= ID: U= ID: U= ID: U= ID: U= ID: U= ID: U= ID: U= ID: 0.32 Non -Metal Frame U -0.32 0.60 Metal Entance Door U -0.60 0.50 Without Curb U -0.50 0.60 Including Curb U -0.60 Page 2 Subtotal Page 1 Subtotal To comply: 1) Proposed Total UA shall not exceed Target Total UA. 2) Proposed Total Area shall equal Target Total Area. Total Area UA 112 45 2659 294 2771 339 Area UA NIL 112 45 2659 324 2771 369 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily SHGC Calculation 2009 Washington State Energy Code Complian Zone 1 Non - Residential ENV -SHGC Project Address Sound Transit Tukwila Station Date 06/15/2012 Fenestration Area as % gross exterior wall area 6. 5% Prop 40% Max.Target For Building Department Use Prescriptive PF Credit 0 Yes O No Vertical North Facing Credit (1323.3 Exp. 2) 0 Yes O No Notes: To comply the Proposed total SHGC x A for all fenestration (vertical & skylights) shall not exceed Target total SHGC x A. If the north facing credit is used then the north and non -north must comply separately with skylights being included with the non -north vertical fenestration. Skylights Proposed SHGC List ID & page #, NFRC or glass only SHGC* x Area (A) = SHGC x E SHGC Target SHGC x Area (A) = SHGC x A ID: ID: ID: ID: ID: 44.8 Total 44.8 0.35 1 Criteria All SHGC , .:0.35 * Note: Manufacturer's SC may be used in lieu of SHGC. Totals Nonresidential compliance is based upon combined skylight and vertical fanactratinn narfnrmanna I7neirinnHal .........L.,...... t.. L........, .. Totals) I only: pun skylight All Non -North Vertical Fenestration ++ Proposed SHGC List ID & page #, NFRC or glass only SHGC+ PF PF Adjusted x Area (A) = SHGC x / Mule SHGC Target SHGC SHGC x Area (A) = SHGC x A ID: ID: ID: ID: ID: ID: ID: ID: ID: ID: 0.40 1.00 0.40 112 45 0.40 112 44.8 Criteria SHGC •AII 0.40 ,'Prescriptive PF 0.45 + +Note: If projection factors or north vertical glazing credit are used Totals then vertical fenestration must be entered according to orientation. If neither are used then ventical fenestration can be entered in either section. Non -North + Note: Manufacturer's SC may be used in lieu of SHGC. Fenestration that separates conditinned cnara from a nnn- rnn,4ifinnarl nr .o.,,■_..,,..rti�l,..,,,a 112.0 44.8 Totals 112.0 44.8 Total 44.8 44.8 shall be listed here with a proposed SHGC equal to the target value. * Note: Multipliers only apply if prescriptive PF credit not used. North Vertical Fenestration ++ Proposed SHGC List ID & page #, NFRC or glass only SHGC+ PF PF Adjusted x Area (A) = SHGC x R Mult* SHGC Target SHGC SHGC x Area (A) = SHGC x A ID: ID: ID: ID: ID: ID: 1 Criteria Mixed North Orientation Separate All ,0.40 0.45 ' Pescrpt P 0:45 030 North Total . I 1 For compliance: Proposed total SHGC x A shall not exceed Target total SHGC x A. If north glazing credit is used then north facing vertical fenestration must comply separately from non -north vertical fenestration and skylights. Area SHGC x A Grand I 112.. 0 Total 44.8 Area Grand I 112 .0 Total SHGC x A 44.8 I 2009 Washin ton State Ener Code Compliance Forms for Nonresidential and Multifamil ,Building Permit Plans Checklist 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Project Address ENV -CHK Revised February 2011 Sound Transit Tukwila Station (Date 6/15/2012 The following information is necessary to check a building permit application for compliance with the building envelope requirements in the WashingtonState Nonresidential Energy Code. Applicability (yes,no,na) Code Section Component • Information Required Location on Plans Building Department Notes GENERAL REQUIREMENTS (Sections 1301 -1314) 1301 Scope Unconditioned spaces Identified on plans If allowed N.A. 1310.2 Semi- heated spaces Semi - heated spaces identified on plans if allowed N.A. 1310.3 Cold Storage / refrigeratr All refrigerated spaces identified on plans. ENV -RFG completed. 1311 Insulation Yea 1311.1 General installation Indicate installation nethod, densities and clearances to achieve intended R -value of all insulation materials -A5.31 A10.15 Yes 1311.2 Roof /ceiling insul. Indicate R -value on roof sections for attics and other roofs; Indicate clearances for attic Insulation; Indicate baffles if eave vents installed; Indicate face stapling of faced batts A5.31 A10.15 Yes 1311.3 Wall insulation Indicate R -value and framing material on wall sections; Indicate face stapling of faced batts; Indicate above grade exterior insulation is protected; Indicate mass of masonry walls if mass wall claimed Indicate loose -fill core insulation for masonry walls as necessary Indicate frequency of grouted cores and bond beams as necessary A5.31 A10.15 N.A. 1311.4 Floor insulation Indicate R -value on floor sections; Indicate substantial contact with surface; Indicate supports not more than 24" o.c.; Indicate that insulation does not block airflow through foundation vents. - Yea 1311.5 Slab -on -grade floor Indicate R -value on wall section or foundation detail; Indicate slab Insulation extends down vertically 24" from top; Indicate above grade exterior insulation Is protected A5.31 A10.15 N.A. 1311.6 Radiant floor Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically 36" from the top; Indicate above grade exterior insulation is protected; Indicate insulation also under entire slab where req'd. by Official - Yes 1312 Glazing and doors Provide calculation of vertical and overhead glazing area as percent of gross wall area 6nvSum Yes 1312.1 U- factors Indicate glazing and door U- factors on glazing and door schedule (provide area - weighted calculations as necessary); Indicate if values are NFRC or default, if default then specify frame type, glazing layers, gapwidth, low -e coatings, gas filling A10.11 -1 Yes 1312.2 SHGC & SC Indicate glazing solar heat gain coefficient or shading coefficient on glazing schedule (provide area - weighted calculations by orientation as necessary) - A10.13 1313 - Moisture control Yea 1313.1 Vapor retarders Indicate vapor retarders applied to warm side of insulation A11.15 Yes 1313.2 Roof /ceiling vap.ret. Indicate vapor retarder on roof section; or list exception Indicate vap. retard. with sealed seams for non -wood structure A11.15 Yes 1313.3 Wall vapor retarder Indicate vapor retarder on wall section All .15 Yes 1313.4 Floor vapor retarder Indicate vapor retarder on floor section A11.15 N.A. 1313.5 Crawl space vap. ret. Indicate required grade ground cover with required overlapping. _ 1314 Air leakage , Yes 1314.1 Bldg. envel. sealing Indicate sealing, caulking, gasketing, and weatherstripping TK -A5.31 Yes 1314.2 Glazing/door sealing Specify maximum air leakage rates for fenestration and door products A11.11 Yes 1314.3 Assemb. as ducts Indicate sealing, caulking and gasketing Mo.01 Yes 1314.4 Recessed Lighting Fixtur Indicate IC rating, ASTM E283 cert., and gasketing or caulking to ceiling A11.11 N.A. 1314.5 Loading Dock Seal Indicate weatherseal at cargo and loading dock doors _ Yes 1314.6 Continuous Air Barrier Indicate air barrier sealing on all roof, wall & floor details Indicate leakage testing method. Provide testing results to building official. Max. leakage of 0.40 cfm /ft2 at 0.3 inch w. TK -A5.31 TK -A8.11 TK -A8.12 PRESCRIPTIVE PERFORMANCE Sections 1320 -1323) Yea ENV -SUM Form Completed and attached. Yes 1323 Glazing Indicate number of glazing panes and location of emissivity coating or exception taker A10.13 COMPONENT PERFORMANCE /`Sections 1330 - 1338)_ Yes I IENV -SUM, ENV -UA, (Completed and attached. & ENV -SHGC Forms 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary MECH -SUM 2009 Washington State Energy Code Compliance Forms for Nonr Project Info - ---- --__...., ..-- .-- .... -. Project Address Sound Transit Tukwila Station r- evrseu reoruary zu11 Date 6/15/2012 Tukwila Wachington For Building Dept. Use Applicant Name: KPFF Consulting Engineers Applicant Address: 1601 Fifth Avenue, Suite Applicant Phone: (206) 622 -5822 Project Description Briefly describe mechanical system type and features. El Includes Plans Split system heat pump for Electrical Room, which has equipment as well as electrical service. Electric fan coil Room. Other rooms heated using electric wall heaters, and provided for make -up air on exhaust systems. Drawings must contain notes requireing compliance with commissioning requirements communication heat for Guard ventilation - Section 1416 Compliance Option O Simple System 0 Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu /h OSA CFM or Econo? SEER ' or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N See Schedule On Plana Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu /h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N See N Schedule • On Plane• Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 CFM SP' HP /BHP Flow Controls Location of Service See Schedule On Plans �If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section 1433. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential ec anica Permit Plans Checklist MECH -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Address Sound Transit Tukwila Station 'Date 6/15/2012 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Ene gy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment Performance Yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M0.02 N.A. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss N.A. 1411.1 Air- cooled chiller Provide total air and water chiller capacity N.A. 1411.2.1 Water - cooled chiller Full -load and NPLV values adjusted for any non - standard conditions Yes 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule M0.02 N.A. 1411.5 Unenclosed Heat . Indicate radiant heat system and occupancy controls 1412 HVAC Controls Yes 1412.1 Temperature zones Indicate locations on plans M1.01 Yes 1412.2 Deadband control Indicate 5 degree deadband minimum MO.01 N.A. 1412.3 Humidity control Indicate humidistat Yes 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback MO.01 Yes 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage m1.01 Yes 1412.4.2 Optimum Start Indicate optimum start controls MO .01 Yes 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule M1.01 N.A. 1412.6 Combustion heating Indicate modulating or staged control Yes 1412.7 Balancing Indicate balancing features on plans M1.01 N.A. 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas N.A. 1412 9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. Yes 1423 Thermostat interlock Indicate thermostat interlock on plans M1.01 N.A. 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers N.A. 1412.1 Single zone systems Indicate multiple cooling stage control capability. N.A. 1413.1 Air Econo Operation Indicate 100% capability on schedule N.A. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb N.A. 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. N.A. 1413.3 Integrated operation Indicate capability for partial cooling N.A. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems Yes 1414.1 Duct sealing Indicate duct design pressures, sealing, and testing requirements M0.01 Yes 1414.1.2 Low press. duct test Indicate applicable low pressure duct systems shall be leak tested M0.01 N • A • 1414.1.3 High press. duct test Indicate high pressure duct systems shall be leak tested, and identify the location of this ductwork on plans Yes 1414.2 Duct insulation Indicate R -value of insulation on duct m0.01 1415 Piping Systems Yes 1415.1 Piping insulation Indicate R -value of insulation on piping MO .01 1416 Completion Requirements Yes 1416.3.2 System Balancing Indicate air and water system balancing requirements m1.01 Yes 1416.3.3 Functional Testing Provide sequence of operations and test procedures. M0.01 Yes 1416.3.4 Documentation Indicate O &M manuals, record drawings, staff training M0.01 Yes 1416.3.5 Comm. Report Indicate requirements for final commissioning report MO.01 1416.4 Compliance Chklist Submit to building official upon substantial completion. Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer zuuu wasnington State tnergy code compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist Continued MECH -CHK:. Revised February 1011 2009 Washington State Energy Code Compliance Forms for Nonresidentiiil and Multifamily Residential Project Address sound Transit Tukwila Station , 'Date 6/15/2012 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington -State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. N.A. 1441 Elec. water heater Indicate R -10 insulation under tank N.A. 1442 Shut -off controls Indicate automatic shut -off of circulators or heat trace Yes 1443 Pipe Insulation Indicate R -value of insulation on piping 140.01 N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. 1460 Heated Pools N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R -12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction COLD STORAGE (Sections 1460 -1465) 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Sections 1401 -1424 or 1440 -1465 , provide explanation: 2009 Washin ton State Ener Code Com•liance Form for Nonresidential and Multifamil Residential Interior Lighting Summary 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Resi LTG -INT Project Info Project Address Sound'Transit Tukwila Station Date 6/21/2012 `V Tukwila, WA For Building Department Use Ancillary Bldg Applicant Name: rasp Flack + Kurtz Applicant Address: boo University Ave, Seattle, WA 98104 Applicant Phone: 206- 342 -9900 Project Description '% New Building • Addition • Alteration • Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). hdicate Prescriptive & LPA spaces dearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) • No changes are being made to the lighting and space use not changed ■ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan/room #) Occupancy Description Allowed Watts per ft2 ** gross intenor Area in ft2 - Allowed x Area Ancillary Bldg Commons Areas - Electrical, Restroom, Guard Room 0.80 975 780 Ancillary Bldg FB - surface mount lensed fixture 14 30 420 _ _ 1 (over) - document all exceptions on form LTG- Proposed Lighting Wattage Total Allowed Watts 780 Location (floor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Ancillary Bldg CB - recessed lensed downlight 2 36 72 Ancillary Bldg FB - surface mount lensed fixture 14 30 420 may not exceed Total Allowed Watts for Interior Total Proposed Watts 492 Notes: 1. For proposed Fixture Description, indicate fixture type, Tamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. zuuu wasnington State trier Code Como Hance Form for Nonresidential and Multifamil Residential Interior Lighting Summary (back) 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential LTG -INT Prescriptive Spaces Occupancy: 0 Warehouse or Parking Garage ,t)♦ Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.85 • Chedc if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. -7 Umt ugnting tower Allow Use' LPAI (W /ft `) Use' LPA1(yy/ ) 0.91 Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 Convention center 1.10 Parking garages _ 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments5, restaurants/bars5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture - 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies° (except mall concourses) _ 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 ootnotes for Table lb- 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w /ft2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter - height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, dothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii,-or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of tad( attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be tumed off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. 2009 Washin ton State Energ Code Come fiance Form for Nonresidential and Multifamil Residential Exterior Lighting Summary 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential LTG -EXT Project Info ProjAddressound Transit Tukwila Station Date 6/21/2012V V Tukwila, WA For Building Department Use Plaza Name: WSP Flack + Kurtz Appl. Name 600 University Ave, Seattle, WA 98104 Appl. Phone 206 - 342 -9900 Project Description '% New • Addition • Alteration • Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Lighting Zone (as specified by Jurisdiction) O Zone 1 Zone 2 0 Zone 3 0 Zone 4 • Compliance Option • Lighting Power Allowance 0 Systems Analysis I I Building Grounds (luminaires > 100 Watts) '� Efficacy > 60 lumens/W • Controlled by motion sensor • Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) • No changes are being made to the lighting and space use not changed. • Less than 60% of fixtures are new, installed wattage not increased, & space use not changed. HC pole mount aea light 1 -head Tradable Maximum Allowed Lighting Wattage Base Site Allowance:I 750 I Tradable Surfaces Description # uowea watts per ft2 or per If Area (ft`), perimeter (If) or # of items Hnowea vvatts x ft2 (or x If) Uncovered Parking and drives Entry drive and surface parking 0.10 W/ft2 210192 21019 Grounds Walkways <10 wide Walkways 0.8 W/LF 9387 7510 Grounds Walkways >10' wide Plazas and platforms 0.16 W/ft2 56714 9074 Stairways Exterior stairs 1.0 W /ft2 1836 1836 Total Allowed Tradable Watts: T- ..- .7 -L7._ if-. 39439 1pOSed Llghtlrig Wattage (use mfgr listed maximum input wattage for luminaire.) Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Plaza HA - pole mount area light 2 -heads 16 350 5600 Walkway HAl - pole mount area light 1 -head 18 175 3150 Platform shelters HB surface mount fixture 92 125 11500 Platform HC pole mount aea light 1 -head 24 175 4200 Parking lot HD parking fixture 2 -heads 10 350 3500 Parking lot HD1 - parking fixture 1 -head 3 175 525 Roadway HE - pole mount are light 1 -head 15 175 2625 Entry stair HF surface mount area light 2 -head 6 180 1080 Ancillary Bldg entry CB - recessed lensed downlight 2 36 • 72 Shelters FA - shelter direct light fixture 42 30 1260 Bike storage FB surface mount lensed direct fixture 23 30 690 Shelters FC - shelter uplight 64 30 1920 Ancillary building tr psformer CA - wall mount area light 1 36 36 Underpass walkway FE - Linear uplight 10 30 300 underpass walkway HG - Side mount downlight 11 30 330 Total proposed tradable watts may not exceed the sum of total allowed tradable watts Total Proposed Tradable Watts: plus the base site allowance. Any base site allowance not needed to make tradable watts comply can be applied to individual non - tradable categories. 36788 Non - Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: 750 Non - Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Non - Tradable Proposed Lighting Wattage Surface Fixture Description Number of Fixtures Watts /. Fixture Watts. Proposed Non - tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non - tradable surfaces are Tess than the remaining site allowance. Total excess Non - Tradable watts: Site Allowance Balance: 0 750 2009 Washington State Energ Code Com.liance Form for Nonresidential and Multifamil Residential - Exterior Lighting Summary (back) LTG -EXT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential TABLE 15 -2B Revised December 2010 Specific area description Zone 1 Zone 2 600 W Zone 3 750 W Zone 4 1300 W Base site allowance' 500 W Tradable Surfaces 2 Uncovered Parking Parking lots and drives Areas 0.04 W /ft2 0.06 W/ft2 0.10 W/ft2 0.13 W /ft2 Building Grounds Walkways less than 10 ft wide 0.7 W /linear foot 0.7 W/ linear foot 0.8 W/ linear foot 1.0 W/ linear foot Walkways 10 ft wide or greater Plaza areas Special feature areas 0.14 W /ft2 0.14 W /ft2 0.16 W /ft2 0.2 W /ft2 Exterior Stairways 0.75 W /ft2 1.0 W /ft2 1.0 W /ft2 1.0 W /ft2 Pedestrian tunnel 0.15 W /ft2 0.15 W /ft2 0.2 W /ft2 0.3 W /ft2 Landscaping 0.04 W /ft2 0.05 W /ft2 0.05 W /ft2 0.05 W /ft2 Building Entrances and Exits / . Main entries 20 W /linear foot of door width 20 W/linear foot of door width X30 W/linear foot of door width 30 W /linear foot of door width Other doors 20 W /linear foot of door width 20 W/linear foot of door width 20 W/linear foot of door width 20 W /linear foot of door width Entry canopies 0.25 W /ft2 0.25 W /ft2 0.4 W /ft2 _ 0.4 W /ft2 Sales Canopies Free standing and attached 0.6 W /ft2 0.6 W /ft2 0.8 W /ft2 1.0 W /ft2 Outdoor Sales Open areas; 0.25 W /ft2 0.25 W /ft2 0.5 W /ft2 0.7 W /ft2 Street frontage for vehicle sales lots in addition to `open area allowance No Allowance 10 W/linear foot 10 W/linear foot 30 W /linear foot Non - Tradable Surfaces° Building Facades No Allowance 0.1 W /ft2 for each illuminated wall or surfaces 0.15 W /ft2 for each illuminated wall or surfaces 0.2 W /ft2 for each illuminated wall or surface Automated teller machines and night depositories 270 W per locations 270 W per locations 270 W per locations 270 W per locations Entrances and gatehouse inspection stations at guarded facilities 0.75 W /ft2 of covered & uncovered area Loading areas for law enforcement, fire, ambulance and other emergency service vehicles _ 0.5 W /ft2 of covered & uncovered area Material handling and associated storage No Allowance' No Allowance I No Allowance 10.5 W /ft2 Drive -up Windows & Doors 400W per drive - through Parking near 24 -hour retail entrances 800 W per main entry R TABLE 15 -2B: 1. Base site allowance may be used in tradable or nontradable surfaces. 2. Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded. 3. Including vehicle sales lots. 4. Lighting power density calculations for the following applications can be used only for the specific application and cannot be trade between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted i the "Tradable Surfaces" section of this table. 5. May alternately use 2.5 watts per linear foot for each wall or surface length 6. May alternately use 3.75 watts per linear foot for each wall or surface length. 7. May alternately use 5 watts per linear foot for each wall or surface length. 8. An additional 90 watts is allowed per additional ATM location. • PET CO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -117 DATE: , 08 -16 -12 PROJECT NAME: SOUND TRANSIT SOUNDER STATION SITE ADDRESS: 7301 LONGACRES WY. X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued D PTMENTS:� ny'�� Bul In Division � ! 1 �� Ire Preve�tlon `1 9 Public Works ❑ Structural ❑ Planning Division Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 08-21 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 09-18-12 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople 1 ter Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name UNIVERSITY MECH CONTR INC UBI No. 578025176 Phone 2063649900 Status Active Address 11611 49Th PI W License No. UNIVMC'343N9 Suite /Apt. License Type Construction Contractor City Mukilteo Effective Date 8/29/1966 State WA Expiration Date 10/3/2014 Zip 982754255 Suspend Date County Snohomish Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status UNIVEMC009C4 UNIVERSITY MECH CONTR INC Electrical Contractor Hvac /Rfrg Lighting Maintenance 2/24/2000 7/30/2014 Active GRANSML982R3 GRANSTON MECHANICAL LLC Construction Contractor General Unused 12/23/2002 1/8/2009 Expired Business Owner Information Name Role Effective Date Expiration Date BUSH, GERALD D President 03/13/2002 Bond Amount GRANSTON, EDWARD B Secretary 03/13/2002 08965196 PETTERSON, DEAN M Treasurer 03/13/2002 SMITH, DOUG Vice President 03/18/2002 TRAVELERS CAS & SURETY CO KOMMERS, EDWARD D Vice President 03/13/2002 09/13/2004 BALDWIN, TERRY L Vice President 03/13/2002 09/10/2003 GRANSTON, FRANK Treasurer 03/18/2002 12/23/2002 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 FIDELITY ii DEPOSIT CO OF MD 08965196 07/31 /2009 Until Cancelled $12,000.0006/04 /2009 6 TRAVELERS CAS & SURETY CO 103335164 07/21./2001 Until Cancelled 07/31/2009 $12,000.00 10/03 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 31 Phoenix Insurance Company, The DTC0526D8270PHX11 06/01/2011 06/01/2014 $1,000,000.0005 /03/2013 30 THE PHOENIX INS CO C0526D8270PHX10 10/01/2010 10/01/2011 $1,000,000.0009 /22/2010 29 PHOENIX INS CO C0526D8270PHX09 10/01/2009 10/01/2010 $1,000,000.0009 /22/2009 28 TRAVELERS PROPERTY CAS INS CO DTE0526D8270TIL07 10/01/2007 10/01/2009 $1,000,000.0009 /19/2008 27 TRAVELERS PROPERTY CAS INS CO DTEC0526D8270TIK07 10/01/2007 10/01/2008 $250,000.0009/21 /2007 https://fortress.wa.gov/lni/bbip/Print.aspx 09/23/2013 A • 0 0 0 0 2 0 00 • • SEPARATE PERMIT REQUIRED FOR 0M Ilumbing Qas Pipkia City of Tukwila LBUILDING DIVISION, REVISIONS' No changes shall be made to the scope of 1 fork 14'ithout prior approval of • k!vila Building Division, t , ,'.. b'v irl F .=��I. r 4re a new � olan submittal in.rnJde additional plan review ft es. FILZ COP' M1)1%7 Permlt Goo. pl^rt !TI AN approval is subject to errors and omissions. /,4,, , , of construction documents does not authori n of Y °y adopted code or ordinance. Receipt n► L l ovecl Yield Copy and conditions is acknowledged: By Date: W340/5 City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE. APPROVED SEP 12 2012 114- City of Tukwila BUILDING DIVISION • GENERAL NOTES. 1. THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW THE EXACT DETAILS AND LOCATIONS, NOR ALL OFFSETS IN DUCTWORK AND PIPING. CONTRACTOR SHALL PROVIDE ADDITIONAL FITTINGS, OFFSETS AND EXTENSIONS IN PIPING, DUCTWORK AND RELATED MECHANICAL INSULATION AS REQUIRED TO MEET THE INTENT OF THE DOCUMENTS. CONTRACTOR SHALL INCLUDE IN HIS BID PROVISIONS TO RELOCATE OR SHIFT PIPING AND DUCTWORK WHERE CONFLICTS EXIST WITH STRUCTURE, ARCHITECTURE OR ELECTRICAL. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OWN COORDINATION BETWEEN ALL OTHER TRADES. DEVELOPMENT OF SHOP DRAWINGS SHALL BE A COLLABORATIVE EFFORT BETWEEN THE GENERAL CONTRACTOR, MECHANICAL CONTRACTOR AND ALL OTHER SUBCONTRACTORS WORKING ON THE PROJECT. SHIFTING OF PIPING, DUCTWORK AND OTHER MECHANICAL ITEMS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TEAM TO MAINTAIN THE INTENT, OF THE DOCUMENTS. 3. MAINTAIN MAINTENANCE & SERVICE ACCESS TO ALL MECHANICAL EQUIPMENT. GENERALLY RUN PIPING & DUCTWORK AS HIGH AS POSSIBLE, AVOID MAJOR WALKWAYS & ACCESS ROUTES. 4. SHEET METAL: ALL PRODUCTS SHALL COMPLY W/ SMACNA DUCT CONSTRUCTION STANDARDS, SECOND EDITION. 5. SEAL ALL DUCT WORK AS REQUIRED BY WASHINGTON STATE ENERGY CODE. 6. PROVIDE LEAK TESTING FOR HIGH AND /OR LOW PRESSURE DUCTWORK AS REQUIRED BY WASHINGTON STATE ENERGY CODE. 7. RATING OF ACCESS DOORS AND /OR ACCESS PANELS THROUGH FIRE - RATED WALLS, SHAFTS, CEILINGS, ETC., MUST EQUAL THE MATERIAL PENETRATED. 8. ALL EQUIPMENT SHALL BE LABELED PER PLAN DESIGNATIONS. 9. ALL RECTANGULAR & ROUND DUCTWORK SIZES SHOWN ARE SHEET METAL. PROVIDE TURNING VANES IN ALL RECTANGULAR 90- DEGREE ELBOWS, & WHERE SHOWN ON ROUND DUCT. 10. PROVIDE NEC CODE MINIMUM WORKING CLEARANCE IN FRONT OF & OVER ANY ELECTRICAL PANEL. OFFSET PIPING & DUCTWORK AS REQUIRED. 11. DUCTWORK SHALL MEET THE INSULATION REQUIREMENTS OF THE WASHINGTON STATE ENERGY CODE. ALL SHEET METAL DUCTWORK SHALL BE INSULATED IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE. 12. ALL PIPING SHALL BE INSULATED IN ACCORDANCE W/ THE WASHINGTON STATE ENERGY CODE, INCLUDING REFRIGERANT PIPING. 13. DIFFUSERS & GRILLES SHALL BE COORDINATED W/ PLACEMENT OF LIGHT FIXTURES. 14. MECHANICAL CONTRACTOR SHALL VERIFY HEIGHT, DEPTH, & LOCATION OF LIGHT FIXTURES TO AVOID ALL CONFLICTS WITH DUCTS, EQUIPMENT & MOUNTING BRACKETS. ALLOW A MINIMUM OF 3" CLEARANCE ABOVE LIGHTING FIXTURES FOR INSTALLATION OF WIRING CONNECTIONS. 15. COORDINATE LOCATIONS OF ALL EQUIPMENT AND APPURTENANCES W/ OTHER TRADES. 16. CONTRACTOR SHALL PROVIDE COMPLETE OPERATING SYSTEMS. 17. WHERE FLEXIBLE DUCTWORK IS SHOWN TO CONNECT TO CEILING DIFFUSERS, PROVIDE 6' MAXIMUM OF FLEXIBLE DUCT. USE INSULATED DIFFUSER BOX AT DIFFUSER. SEE DETAIL 2, SHEET M1.01. 18. PROVIDE VOLUME DAMPERS AT ALL BRANCHES FOR BALANCING. 19. PROVIDE FLEXIBLE CONNECTORS AT SUPPLY AIR & RETURN AIR CONNECTIONS TO EQUIPMENT 20. MECHANICAL SYSTEMS SHALL COMPLY W/ CHAPTER 14 OF THE WASHINGTON STATE ENERGY CODE. 21. CONTROLS SHALL ALLOW FOR AIR SYSTEM TEMPERATURE RESET, MINIMUM 5- DEGREE DEAD BAND, OPTIMUM START, AND NIGHT SETBACK 22. PROVIDE O &M MANUALS, OWNER TRAINING, AND RECORD DRAWINGS PER SPEC SECTIONS 20 08 00. BALANCE AIR AND WATER SYSTEMS PER SECTION 23 05 93. COMMISSION SYSTEMS PER SECTIONS 20 08 00. RECEIVED AUG 16 2012 PERMIT CENTER MD: 117 • MECHAN 1 CAL LEGEND SYMBOL DESCRIPTION COLD WATER (CW) HOT WATER (HW) WASTE OR SANITARY SEWER (W OR SS) - - VENT (V) FIRE SPRINKLER PIPING F PIPE DOWN cl PIPE UP O1 +1 BRANCH - SIDE CONNECTION 1 CAP END OF PIPE FLOW DIRECTION a FLUSH CLEANOUT (FCO) OR SURFACE CLEANOUT (SCO) AS INDICATED NON- FREEZE WALL BOX HYDRANT (NFBH) GATE VALVE (GV) CHECK VALVE (CV) TEMPERATURE /PRESSURE RELIEF VALVE (T &PV) STRAINER UNION BALL VALVE (BY) DRAIN VALVE WITH HOSE CONNECTION OR HOSE BIBB I AUTOMATIC OR MANUAL AIR VENT (AAV, MAV) 0 PRESSURE GAUGE �THERMOMETER 11 REDUCED PRESSURE BACKFLOW PREVENTER RPBP FLOOR DRAIN (FD) 0 FLOOR & FUNNEL DRAIN (F &FD) • SUPPLY AIR -DUCT UP ► EXHAUST /RETURN AIR - DUCT UP ■IM SUPPLY AIR - DUCT DOWN 14MZEIW, EXHAUST /RETURN AIR - DUCT DOWN =NM 12/12 RR AIR TERMINAL SIZE, TYPE & CUBIC FEET PER MINUTE (CFM) 300 C M CEILING AIR TERMINAL - SQUARE IN + BACKDRAFT DAMPER (BDD) u FLEXIBLE CONNECTION (DUCT) + 111 + OT ROOM TEMPERATURE SENSOR /THERMOSTAT —A . COMBINATION FIRE /SMOKE DAMPER (CFSD) G.C. GENERAL CONTRACTOR M.C. MECHANICAL CONTRACTOR E.C. ELECTRICAL CONTRACTOR W WALL CLEAN OUT SCO SURFACE CLEAN OUT FCO FLOOR CLEAN OUT T &P TEMPERATURE AND PRESSURE RELIEF VALVE BFV BUTTERFLY VALVE RD ROOF DRAIN ORD OVERFLOW ROOF DRAIN POC POINT OF CONNECTION Designed By scs Drawn By TMP tirrail Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Scale: NO SCALE Filename: TK —MO.0 I .dwg Contract No.: RTA /CP 0101 -05 SOU \3 TRA T`. KW \.ST T LA, WAS 90% PER KWILA STAT O\ V I T S.,BMITTAL Drawing No.: TK -M0.0I \ GTO\ MECHAN 1 CAL LEGEND AND GENERAL NOTES Submitted: Date: 06/1 Approved: Date: Date: 06/15/12 • • • DUCTLESS SPLIT SYSTEM OUTDOOR UNIT SCHEDULE UNIT N SERVICE MFR MFR /MODEL COOLING HEATING SEER POWER CONNECTION OPERATING WEIGHT (LBS) NOTES TOTAL MBH OA CF) TOTAL MBH OA (•F) MCA MOP VOLT /PH CU -1 ELECTRICAL ROOM MITSUBISHI PUZ— HA3ONHA2 30 95 19 17 16.1 28 30 208/1 265 p® NOTES: 10 DO NOT EXCEED MAXIMUM TUBING LENGTH. 0 M.C. TO PROVIDE POWER WIRING TO INDOOR UNIT PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. DUCTLESS SPLIT SYSTEM INDOOR UNIT SCHEDULE UNIT NO SERVICE MFR MFR /MODEL CFM TOTAL COOLING MBH EAT POWER CONNECTION (2) OPERATING WEIGHT (LBS) FILTER SEER NOTES DB ('F) - WB ('F) FLA MCA VOLT /PH AC -1 ELECTRICAL ROOM MITSUBISHI PCA— A3OKA4 565 30 80 67 0.54 1 208/1 71 WASHABLE 16.1 O© ©O NOTES: 0 410a REFRIGERANT 0 POWER CONNECTION FROM OUTDOOR UNIT 0 PROVIDE W/ HARD —WIRED WALL — MOUNTED REMOTE CONTROLLER 0 PROVIDE W/ INTEGRAL CONDENSATE PUMP C FAN SCHEDULE UNIT NO MFR MODEL AREA SERVED TYPE PERFORMANCE POWER CONNECTION BACK DRAFT DAMPER SPEED CONTROLLER WEIGHT (POUNDS) NOTES CFM TSP (IN) RPM SONES HP /W VOLT /PH EF -1 COOK GN 162 RESTROOM IN LINE 130 0.25 1074 2.0 86 W 120/1 YES YES 18 0© EF -2 COOK GN 162 JANITOR CEILING 130 0.25 1074 2.0 86 W 120/1 YES YES 18 O© NOTES: 0 SWITCH W/ ROOM LIGHTS O PROVIDE W/ FACTORY —WIRED SPEED SWITCH & WHITE ALUMINUM GRILLE GRILLE, REGISTER, DIFFUSER AND LOUVER SCHEDULE UNIT NO SYMBOL AIR TERMINAL EGH EXHAUST GRILLE: TITUS MODEL 50 -F FOR INSTALLATION IN HARD CEILING. PAINT DUCT MATTE BLACK BEHIND GRILLE. FINISH' SHALL BE #26 WHITE. SEE PLANS FOR SIZES. WTG WALL TRANSFER GRILLE: TITUS' MODEL 350 —RL STEEL GRILLE WITH HORIZONTAL BLADES SPACED 3/4" AND 35' DEFLECTION. SEE PLANS FOR SIZES. PAINT DUCT MATTE BLACK BEHIND GRILLE. FINISH SHALL BE #26 WHITE. TURN BLADES UP. SWSG SIDEWALL SUPPLY GRILLE: TITUS MODEL 300 —FL DOUBLE DEFLECTION REGISTER WITH 3/4" BLADE SPACING. FINISH SHALL BE #26 WHITE. WPL LOUVER; SEE ARCHITECTURAL PLANS AND SPECIFICATIONS ELECTRIC POINT OF -USE WATER HEATER SCHEDULE UNIT NO AREA SERVED LOCATION MFR MODEL ELECTRICAL TEMP. RISE F. GPH ® 60° RISE CAPACITY (GALLONS) OPERATING WEIGHT LBS NOTES VOLT /PH KW WH -1 ANCILLARY BUILDING ROOM 104 IN— SINK — ERATOR W -154 120/1 1.5 80' 10.4 4 15 INCLUDE 3' CORD WITH GROUNDED PLUG PLUMBING FIXTURE SCHEDULE FIXTURE NO FIXTURE DESCRIPTION /MFR /MODEL NUMBERS LOCAL PIPING CONNECTION NOTES W V CW HW P -1A WATER CLOSET DURA —WARE, WALL HUNG, COMPACT SIPHON JET: ACORN ENGINEERING `2105— T— i —FVBO —ADA, DUAL FLUSH VALVE: SLOAN "SOLIS" 8111- 1.6/1.1 —BN SOLAR POWERED DUAL FLUSH CARRIER: ZURN 1203 -N4 —XH OR 1204— N4 —XH, 500 LB MISC: MOUNT FLUSH CONTROLS 44" AFF; MOUNT W/ SEAT AT 17" TO 19" AFF 4" 2" 1" - HANDICAPPED DUAL FLUSH P -2A URINAL DURA —WARE, WALL HUNG, WASHDOWN: ACORN ENGINEERING 2158— T- 1 -FVBO —ADA, 0.5 GALLON FLUSH "SOLIS" VALVE: SLOAN SOLIS 8186 -0.5 SOLAR POWERED SENSOR ACTIVATED CARRIER: PROVIDED FOR WALLS UP TO 8" THICK. MISC: MOUNT FLUSH CONTROLS 44" AFF; MOUNT W/ RIM NO MORE THAN 17" AFF 2" 1 -1 2" / 3/4" / — HANDICAPPED P -3A LAVATORY DURA —WARE, WALL HUNG, 18 "x22 ": ACORN ENGINEERING 1953LC— ADA- 1— DMS- 9— H1— GT —TPT, TAILPIECE /TRAP INCLUDED FAUCET: SLOAN "SOLIS" EAF- 275 —ISM, 0.5 GPM SOLAR POWERED WITH INTEGRAL SPOUT TEMPERATURE MIXER. ETF -312A 4 "CC TRIM PLATE SUPPLIES: BRASSCRAFT NO. SCR1912AC, OR EQUAL BY McGUIRE OR EASTMAN HANGER: CONCEALED ARM CARRIER ZURN 1231 MISC: PROVIDE POWERS E480 POINT OF USE MIXING VALVE, OR APP'D EQUAL ON HOT WATER PIPING. PROVIDE HOT /COLD WATER SUPPLY AND WASTE PROTECTION — TRAP WRAP BY BROCAR PRODUCTS, INC. OR HANDI —LAV —GUARD BY TRUEBRO, INC. MOUNT LAV W/ RIM AT 34" AFF SO THAT CLEARANCE HEIGHT IS AT LEAST 29" 2" 1-1/2" 1/2" 1/2" HANDICAPPED P -5 SERVICE SINK FLOOR MOUNT, 36 "x24 ", MOLDED STONE, STAINLESS STEEL DOME STRAINER: FIAT NO MSB- 3624 FAUCET: ADJUSTABLE INLETS, VACUUM BREAKER SPOUT, PAIL HOOK WITH WALL SUPPORT, INTEGRAL STOPS, 3/4" HOSE THREAD OUTLET: CHICAGO FAUCET NO. 897 —CP TRAPS & TAILPIECES: PROVIDED. WITH UNDERGROUND PIPING SUPPLIES: INTEGRAL TO FAUCET MISCELLANEOUS: PROVIDE FIAT 832 —AA 30" LONG 3/4" HOSE AND HOSE BRACKET, AND FIAT 889 —CC STAINLESS STEEL MOP HANGER. SEAL SEAM BETWEEN SERVICE SINK AND WALL WITH FIAT 832 —AA SILICONE SEALANT. PROVIDE STAINLESS STEEL WALL GUARD TO EXTEND UP WALL 2 SIDES TO APPROX. 42" AFF 3" 2" 3/4" 3/4" FLOOR MOUNTED P -6 ELECTRONIC TRAP PRIMER ELECTRONIC TRAP PRIMING MANIFOLD, PRECISION PLUMBING PRODUCTS MP- 500 -115V. PROVIDE WITH DISTRIBUTION UNIT & RECESSED MOUNTING BOX W/ STAINLESS STEEL ACCESS DOOR _ _ 1 / 2 " ELECTRIC HEATER SCHEDULE UNIT NO. MFR MODEL LOCATION WATTS SIZE VOLT /PM NOTES EH -1 MARKEL E3055TDWB RESTROOM 1500 10 "x12 "x3" 120/1 1 2 EH -2. MARKEL E3055TDWB JANITOR 1500 10 "x12 "x3" 120/1 1 2 EH -3 MARKEL E3055TDWB HALL 1500 10 "x12 "x3" 120/1 0O EH -4 MARKEL E3055TDWB STORE ROOM 1500 10"x12 "x3" 120/1 00 NOTES: 0 WALL MOUNTED; PROVIDE W/ MANUFACTURER'S MOUNTING FRAME 0 INTEGRAL THERMOSTAT W/ "OFF" POSITION, MOUNTED ON UNIT ELECTRIC CABINET HEATER SCHEDULE UNIT NO MFR MODEL AREA SERVED CFM MOTPOR COIL kW POWER CONNECTION DISCONNECT NOTES VOLT /PH MCA MOP CH -1 TRANE FFCB020 • GUARD 250 1/15 3.0 208/3 12.5 15 BY E.C. 0000 NOTES: 0 BOTTOM RETURN 0 OUTSIDE AIR DAMPER, AUTO TWO POSITION, BACK OUTSIDE AIR OPENING 0 FRONT DUCT COLLAR 0 2 —STAGE HEAT EXPANSION TANK SCHEDULE UNIT NO MFR MODEL SERVICE ' TYPE TANK VOLUME MAX SIZE INCHES NOTES DIAMETER , HEIGHT ET -1 ARMSTRONG ST -5 —C WH -1 BLADDER 2.1 10 10 -3/8 1002 NOTES: 0 NSF RATED FOR POTABLE WATER 0 ASME RATED MIXING VALVE SCHEDULE UNIT NO. MFR MODEL SERVICE WATER CONNECTIONS NOTES CW INLET HW INLET OUTLET MV -1 LEONARD 370 120° HW 3/4" 3/4" 3/4" WALL MOUNTED CERTIFIED LEAD —FREE MIS -117 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 12 2012 City of Tukwila BUILDING DIVISION 90% PERV Designed By SCS Drawn By TMP Checked By DMM No. Date By Chk. App. Revisions Approved By WYL Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Scale: NO SCALE Filename: TK— M0.02.dwg Contract No.: RTA /CP 0101 -05 Submitted:. Date: Approved: Date: Date: 06/15/12 SOJNJD TRA \ST TUKWILA STAT O TUKWILA, WASH \GTO\ MECHAN 1 CAL SCHEDULES RECEIVED AUG 16 2012 PERMIT CENTER T S, BV TTA.L Drawing No.: TK -MO.02 Sheet No.: Rev.: 287 JI- Z 3/4" RELIEF VALVE SET 0 65# —\ o 1— _ V NOTES: 1. ALL MATERIALS IN CONTACT WITH WATER TO BE COPPER, BRASS, BRONZE, EPDM, OR STAINLESS STEEL. SERVICE SINK MA i rl 411 1 LUG —TYPE BUTTERFLY VALVE - - - - _J J 1 TO BUILDING GO VALVE 11-1454 w 00 1 m a0) -3" WATER HAMMER ARRESTOR 2" HEADER 1 BLIND FLANGE PRESSURE REDUCING VALVE; 33 GPM CAD 80 PSI INLET & 60 PSI OUTLET 1 RPBP 1 I� I GALVANIZED STEEL SLEEVE 1" ABOVE FF WITH LINK SEAL n RPBP 1-- -TO SITE BOX WALL HYDRANTS AIR GAP FITTING — PIPE. DISCHARGE FULL SIZE TO DRAIN r FINISHED FLOOR SUPPORT PIPES 5' FROM BLDG DOMESTIC WATER HEADER SCALE: NONE DUCT TAPE CUT 1-1/2" RIGID INSULATION TO FIT. ATTACH WITH DUCT TAPE CON CRETE BY G.C. FLOOR DRAIN BODY DURING CONCRETE POUR (STEP #1) INSTALL STRAINER, STRAINER HEAD, & FLASHING COLLAR (SET FINAL ELEV) FINAL CONNECTION BY M.C. 2" BUILDING SERVICE REMOVE AND STORE STRAINER, STRAINER HEAD AND FLASHING COLLAR PIPE SIZE AS NOTED ON PLANS CW SUPPLY I— — — ACCESS ON WALL COORDINATE LOCATION W/ G.C. STRAINER HEAD STRAINER FINISHED L GROUT BY M.C. TRAP PRIMER 1 VALVE 1 DISTRIBUTION` UNIT l -1 FLOOR DRAIN BODY CONCRETE BY G.C. PIPE SIZE AS NOTED ON PLANS FLASHING COLLAR AFTER CONCRETE HARDENS (STEP #2) NOTE: COMPLETE INSTALLATION OF FLOOR DRAIN AND SETTING OF FINAL ELEVATION WILL NOT BE ALLOWED DURING INITIAL CONCRETE POUR FLOOR DRAIN INSTALLATION SCALE: NONE TO FLOOR DRAINS HW TO FIXTURES — SIZE AS SHOWN ON PLAN 5---1207 -- - IN —LINE FLOW CONTROL THERMOMETER (30' -180') ASME RATED COMBINATION TEMPERATURE & PRESSURE RELIEF VALVE INSTANT -FLOW WATER HEATER WH -1 CORD AND GROUNDED PLUG POWER GFCI RECEPTACLE FINISHED FLOOR —\ NOTE: WATER HEATERS AND EXPANSION TANKS SHALL HAVE SEISMIC SUPPORTS ATTACHED `TO STRUCTURE DESIGNED BY OTHERS (TYPICAL) MV -1 r, CW — SIZE AS SHOWN ON PLAN EXPANSION TANK ET -1 PIPE FULL SIZE TO MOP SINK L__., SERVICE SINK I NSTANT -FLOW WATER HEATER M1. 02 1 NSTALLAT 1 ON SCALE: NONE ADJUSTABLE WALL CLAMP NFBH — NON— FREEZE WALL BOX HYDRANT KEY — OPERATED VALVE VACUUM BREAKER HOSE CONNECTION \\ INTERIOR FACE \\ OF WALL LOCKING COVER EXTERIOR FACE OF WALL KEY NON - FREEZE WALL BOX HYDRANT (NFBH) SCALE: NONE WEATHERPROOF LOUVER PER PLANS OUTSIDE WALL DIMENSIONS PIPE SIZE (OUTSIDE DIAMETER) BASE DIAMETER UNIT HEIGHT 1/4" to 3" 7 -3/4" 4" 4" to 6" 10 -3/4" 5" 15' -0" MIN FROM ANY FRESH AIR INTAKE DEK -11TE (OR APP'D EQUAL) PIPING FLASHING (SIZE AS SHOWN BELOW) PIPE DIAMETER 1/2" MIN. 1 12" MIN UNIT HEIGHT BASE DIAMETER METAL ROOF P I PE FLASHING SCALE: NONE BIRDSCREEN INSULATION PER SPECIFICATIONS PLENUM AS SHOWN ON PLANS SELF— ADHERING RUBBERIZED ASPHALT FLASHING 6" SLOPE ?j.,z.. r t5 S2S25?S144Q0 PROVIDE 1/2" SPACE BETWEEN BOTTOM OF BIRDSCREEN AND BACK EDGE OF LOUVER TO ALLOW DRAINAGE COORDINATE HYDRANT INSTALLATION WITH ARCHITECTURAL PLANS, SEE SHEETS TK —A8.40 FOR KIOSK DETAILS 18" FACE OF KIOSK WALL HYDRANT KEY 6" SCHEDULE 40 SLEEVE FINISHED GRADE /FLOOR 18" ACTSSWIRR:712:SS I= ., 1•t • • • • I•: • • • 1t • • • • • • • Lil • • • • • 1:1 • • •'; • • I: • • • • 1 • • • • • • • 15" PROVIDE MINIMUM 24" COVER 17 REVIEWED FOR ODE COMPLIANCE } APPROVED SEP i 2 2012 City of Tukwila BUILDING DIVISION WEATHERPROOF LOUVER I NSTALLAT I ON SCALE: NONE HEAT TRACE & INSULATE WATER PIPING FROM 18" BELOW GRADE TO BACK. OF 1 FREEZELESS WALL HYDRANT. ELECTRICAL TO BE SOURCED FROM 120V CIRCUITS 1_ SERVING KIOSK 3/4" TYPE K COPPER PIPE 1" TYPE K COPPER PIPE TYPE K COPPER SUPPLY. MAIN; SIZE AS SHOWN ON PLAN K 1 OSK FREEZELESS WALL HYDRANT SCALE: NONE REFRIGERANT PIPING SIZE AS RECOMMENDED BY , EQUIPMENT MANUFACTURER PIPE INSULATION PER SECTION (BOTH LINES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS) "UNICUSHION" VIBRATION ELIMINATING PAD ALL SUPPORTS UNISTRUT — LAG TO 2x6's ® 24" O.C. PIPE CLAMP (TYP.) NOTES: PROVIDE PIPING SUPPORT AS SHOWN AT ALLOWABLE SPACING AS NOTED IN SPECIFICATIONS FOR PIPE HANGERS. COVER ENTIRE LENGTH OF EXPOSED PIPING ON EXTERIOR WALL 4 W/ ) 24 G EPDXY PAINTT METAL FLASHING. (2) COATS PRIMER, RECEIVED REFRIGERANT PIPING ON Au616 2012 EXTER I OR WALL SCALE: NONE 90% PER PERMIT CENTER v T S „BV Drawing No.: Designed By sc5 Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Scale: NO SCALE Filename: TK— M0.03.dwg Contract No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 SOUN IRA T, SIT TU <WI L_A STAT <WI LA, WASH \ GTO MECHANICAL DETA 1 LS 0\ TTAL TK -MO.03 Sheet No.: Rev.: 288 • • • • • UNISTRUT (2) CH -1 UNISTRUT (2) FLEXIBLE CONNECTION (TYP.) CONNECT TO STRUCTURE; SEE STRUCTURAL PLANS FOR STRUCTURE TYPE 4 (TYP.) VIBRATION ISOLATOR (TYP.) BOTTOM RETURN OPENING CEILING - MOUNTED FAN OR CAB 1 NET HEATER 1 NSTALLAT 1 ON SCALE: NONE 4 "0 OUTSIDE. AIR CONNECTION 0 32/12 WPL ■ NDOOR AIR HANDLER OUTSIDE AIR CONNECTION TO LOUVER SCALE: NONE U -1 M1.03 O 14/12 WP CONDENSATE DRAIN PIPING 32/12 8/8 WTG BOTH SIDES W/ SHEETMETAL SLEEVE) O CONDENSATE PIPING DN TO SERVICE SINK FILTER RACK W/ 1" FILTERS 6/6 EGH 100 CFM /8 WTG BOTH SIDES V/ SHEETMETAL SLEEVE) CEILING ACCESS PANEL; SEE SHEET 5/A2.11 RETURN ON BTM OF UNIT 32/12 WPL —4--- 16/8 SOUNDLINED v 1 /8 SWSGI. 2 0 CFM 16/8 TG BOTH IDES W/ SHEETMETAL SLEEVE (TYP.) ANCILLARY BUILDING - MECHAN I CAL PLAN SCALE: 1 /4" = 1 ' - 0" TKM 1.00 PLAN NOTES 0 LOUVER IS TO FIT INTO FRAME; SEE SHEET TK— A10.11 FOR EXACT SIZE AND LOCATION. SEE DETAIL 7 /TK —M0.03 FOR PLENUM REQUIREMENTS 2O SEE SHEET TK —A4.11 FOR EXACT LOCATION 03 MOUNT EQUIPMENT SO AS TO PROVIDE MAXIMUM HEAD HEIGHT AVAILABLE O 7 —DAY PROGRAMMABLE REVIEWED FOR ! 40DE COMPLIANCE APPROVED SEP122012 City of Tukwila BUILDING DIVISION ((2: 117 4 2 4 SCALE IN FEET RECEIVED AUG 162012 PERMIT CENTER 90% PERU Designed By scs Drawn By. TMP No. Date By Chk. App. Revisions Checked By DMM Approved B. WYL Consulting Engineers 1601 Fifth Avenue, Suite. 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Scale: 40 = nII Filename: TK —M I.OI .dwg Contract No.: RTA /CP 0101. -05 Submitted: Date: Approved: Date: Date: 06/15/12 SO„ f\ 3 TRANSIT TU K WI LA STAT O T, K W LA, WAS \ G TO\ ANCILLARY BUILDING — MECHAN I CAL T SUBVV TTAL Drawing No.: TK- M I.0 I Sheet No.: 290 Rev.: • • 2" AREA DR IN 3 "0 STAIN SS STEEL DOWNSPe T UP TO GUTTER (REF. ' - A5.21) & DOWN TO STO (REF. DK- DR.02) O LECTRONIC TRAP PRIMER; CCESS FROM JANITOR ROS M0.03' DO ESTI HE DER /2"CW 3 /4 "HW P -5 o4" 2 —WAY SCO 16' -2" 1"CAP FOR FUTURE AREA DRAIN TO STORM; SEE TK -DR.02 & TK -UC.02 T &P: DRAIN FULL SIZE TO SERVICE SINK P -5 41 1 /2"NON- POTABLE- WATER TO SITE; FOR CONTINUATION SEE SHEETS TK ,M,1 X11 _ THROUGH TK -M1.14 3 /4 "CW FIRE SPRIN SEE SHEET FOR FIRE SPRIN PLAN & DETAILS ER HEADER, -M1.03 AP MER VALVE 2 "V 4 "V UP TO 4 "VTR 2 "V M0.03 FWH 2" AREA DRAIN 1' -8" • POC 1 5' -0" TO BLDG EDGE (TYP.) 0 3 "0 STAINLESS STEEL DOWNSPOUT UP TO GUTTER (REF. TK- A5.21) & DOWN TO STORM (REF. DK- DR.02) • POC FOR CONTINUATION SEE TK -UC.02 POC; 4" 2 -WAY SCO ■■■ 5' -0" TO ,BLDG EDGE (TYP.) 2 "STORM UP TO L� 2 "DOMESTIC CW SERVICE 4 "SS 4" 2 -WAY SCO 5' -0" 1I — .p -1- 1 1 1 1 1 1 $ PLAN NOTES -1/21 - ...FOR NON- POTABLE CW TO SITE 1 4 "VTRJIL 2"-\ - FIRE SPRINKLER STANDPIPE DRAIN, SEE SHEET TK -M1.03 FOR FIRE SPRINKLER PLAN AND DETAILS DOWNSPOUTS - SEE DETAIL 4 /TK -M1.00 & ARCHITECTURAL DETAILS 8/TK -A8.15 & 11/TX-8.15 ROOF I---4- - ++- 2 . 12 -F- n CEILING 2FU 2 "FD POC fik\ 2 "-1 1- 1 /2 "NON,POTABLEp WATER ur �"' L F FIRE SERVICE • POC FIRE PROTECTION SUPPLY, SEE SHEET TK -M1.03 FOR FIRE SPRINKLER PLAN & DETAILS AREA DRAIN TO STORM; SEE TK -DR.02 & TK -UC.02 P -6 ELECTRONIC TRAP PRIMER; ACCESS FROM STORAGE ROOM 3 "s ST�i DOWNSP (REF. T . STORM INLESS STEEL UT UP TO GUTTER K 5.21) & DOWN TO (RE K- DR.02) n ANC ILLAY BUILDING — SCALE: 1/4" = 1' -0" PLUMBING PLAN 4 "S U 2 "s • POC 3 "93 STAINLESS STEEL DOWNSPOUT UP TO GUTTER (REF. TK- A5.21) & DOWN TO STORM (REF. DK- DR.02) TK—M1.0 0 2 "STORM UP TO AREA DRAIN 1 4 "SS UP UP WCO 1 -1/2 "NON "=POTABLE CW WATER TO SITE, FOR CONTINUATION SEE SHEET TK -M 11 L_1 ANC 1 LLARY BU II LD 1 NG - FOUNI�AT 1 ON PLAN SCALE: 1/4" = 1' -0" Designed By. scs Drawn By TMP No. Date By Chk. App. Revisions Checked By DMM Approved By WYL Consulting Engineers. 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 TRES WEST ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 T SOUNDTRANSIT Scale: 4 "- 2" W EC (/) o 1-O -J cnZZ .7a coots 2" 1 2FU 2 "FD 2" 2FU RR) P -2A CO% 2 ■\ 2 "-ti1 1FU P -3AA V CO% 2 "-. C-� 2» 3FU �STO JAN 2 "FCO P -5 WCO I h FINISHED FLOOR n 2 n 4" 4 "J 2" n 2\ 3" / 7 / 4 "] SANITARY SEWER AND VENT RISER DIAGRAM SCALE: DIAGRAMMATIC TK —M1.02 4 (2-- TK—M1.0 0 4" = 11 2 SCALE IN FEET 90% P =RN ECEIVED AUG 162012 PERMIT CENTER IT S,B V TTAL X11 Filename: TK -M 1 .02.dwg Contract No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 SOU\ TRA\ SI I TUKWILA STAT TUKWILA, WAS-II \ G TO \ ANCILLARY BUILDING PLUMBING O\ Drawing No.: TK —M 1.02 Sheet No.: Rev.: 291 • • E • STRAINER �+- -F TO BUILDING FOR CONTINUATION 5' -0" TO rBLDG EDGE SEE TK —UC.02 1 F • POC FIRE PROTEC SUPPLY MAIN F IRE DEPARTMENT ONNECTION 42" ABOVE* 1NISHED GRADE FIRE SPRINKLER HEADER STANDPIP DRAIN —\ C Iry FIRE SPRINKLER HEADER { 3 M1.03 ANCILLARY BUILDING FIRE SPRINKLING PLAN SCALE: 1 /4" = 11-0" 6 "0 STANDPIPE DRAIN FOR FIRE SPRINKLER SYSTEM BRACKET 2 "VENT PIPE WATER MOTOR GONG OUTSIDE WALL - STRAP TO WALL. COORDINATE WITH FIRE SPRINKLER CONTRACTOR 30" FLOOR PROVIDE P —TRAP WITH TRAP PRIMER FIRE SPRINKLER HEADER STANDP. I PE DRAIN DETA I L SCALE: NONE TK—M1.00 FIRE DEPARTMENT CONNECTION F 1 F CHECK VALVE FIRE SPRINKLER HEADER STANDPIPE DRAIN RETARD CHAMBER WITH PRESSURE SWITCH MAIN DRAIN AND FLOW TEST VALVE WET PIPE ALARM CHECK VALVE AND PRESSURE GAUGES TO FIRE ALARM PANEL —OS & Y VALVE WITH TAMPER SWITCH DOUBLE DETECTOR CHECK VALVE ASSEMBLY 'W J FIRE PROTECTION SUPPLY MAIN' 5--- -F PROVIDE STEEL PIPE SLEEVE (TYPICAL) EXTEND 1"ABOVE FINISHED FLOOR. INSTALL WITH LINK SEALS NOTES 1. PROVIDE PIPE SUPPORTS AND ANCHORS AS REQUIRED TO SUPPORT ENTIRE VALVE ASSEMBLES. 2. THIS DIAGRAM IS PRESENTED AS AID TO CONTRACTOR. IT DOES NOT RELIEVE CONTRACTOR FROM MEETING ALL REQUIREMENTS OF NFPA 13 AND LOCAL AUTHORITIES. FIRE SPRINKLER HEADER DIAGRAM SCALE: NONE PLAN NOTES 0 COORDINATE PENETRATION SIZE AND LOCATION WITH STRUCTURAL ENGINEER FIRE SPRINKLING GENERAL NOTES 1. DESIGN, FURNISH AND INSTALL A COMPLETE "WET PIPE" AUTOMATIC SPRINKLING SYSTEM FOR THE ANCILLARY BUILDING INCLUDING AREAS ABOVE AND BELOW CEILINGS, ATTIC SPACES, INTERSTITIAL SPACES. THE AUTOMATIC SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13 (IBC 903.31 STANDARDS), IBC, IFC AND ALL LOCAL CODES AS A MINIMUM STANDARD. ADDITIONAL REQUIREMENTS ARE NOTED IN THE SPECIFICATIONS OR IN THESE DRAWINGS. 2. PROVIDE COVERAGE FOR THE ENTIRE ANCILLARY BUILDING INCLUDING AREAS ABOVE AND BELOW CEILINGS, ATTIC SPACES, MEZZANINES, INTERSTITIAL SPACES, OVERHANGS AND MECHANICAL /ELECTRICAL ROOMS. THE ASSUMPTION OF FIRE ALARM DEVICES OR SYSTEMS BEING INSTALLED DOES NOT RELIEVE THE FIRE SPRINKLING CONTRACTOR OF PROVIDING COVERAGE IN ALL AREAS. . THE INTENT OF THIS DRAWING IS TO SHOW THE ROUTING OF THE LARGER FIRE SPRINKLER MAIN IN CRITICAL AREAS. ALL PIPING SHALL BE CONCEALED EXCEPT FOR WHERE NOTED ON THIS DRAWING. ANY DEVIATIONS IN THE FIRE MAIN LAYOUT SHOWN HERE SHALL BE APPROVED BY THE ARCHITECT DURING SUBMITTAL PROCESS BEFORE INSTALLATION AND SHALL BE AT NO ADDITIONAL COST TO THE OWNER. NO EXPOSED PIPING WILL BE ALLOWED IF, IN THE BUILDING STRUCTURE, THE ARCHITECT HAS PROVIDED SHAFTS, FURRED AREAS, OR CONCEALED SPACES WHERE PIPING COULD BE HIDDEN FROM VIEW. DO NOT RUN PIPING OVER ELECTRICAL PANELS OR SWITCHGEAR EXCEPT WHERE LOCATED ABOVE THE STRUCTURAL CEILING. 4. FIRE , SPRINKLER MAIN NOT SHOWN SHALL BE LAID OUT PER FIRE SPRINKLER COVERAGE REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS FOR AREAS NOT SHOWN OR FOR MULTIPLE FLOORS THAT REQUIRE FIRE SPRINKLING COVERAGE. . THE FIRE SPRINKLER CONTRACTOR SHALL COORDINATE THE LOCATION OF THE PIPING AND HEADS TO AVOID INTERFERENCES WITH LIGHT FIXTURES, HEATING /COOLING EQUIPMENT, DUCTWORK AND ANY ARCHITECTURAL FEATURES SUCH AS EXPOSED SLOPE ROOF STRUCTURES, SKYLIGHTS, •STAIRWAYS, ETC. IN CATWALK AREAS, PIPING SHALL BE RUN AS HIGH AS POSSIBLE TO ALLOW THE MAXIMUM HEADROOM OVER THE MECHANICAL EQUIPMENT AND AISLE SPACES. MAXIMUM CLEARANCE SHALL BE MAINTAINED FOR SERVICE ACCESS AND MAINTENANCE FOR ALL EQUIPMENT. FAILURE TO COORDINATE SHALL BE JUSTIFICATION TO REQUIRE THE FIRE SPRINKLER CONTRACTOR, AT HIS OWN EXPENSE, TO MOVE AND REDO HIS WORK. 6. IT SHALL BE THE FIRE SPRINKLER CONTRACTOR'S FULL RESPONSIBILITY TO INSTALL A COMPLETE WORKING SYSTEM MEETING ALL CODES. 7. COORDINATE ALL SPRINKLER HEAD LOCATIONS WITH LIGHTING, MECHANICAL, AND ALL OTHER CEILING APPURTENANCES. SEE TK— A2.11, TK— M1.01, & TK —E2.11 MIXtaft- 117 4 2 0 4 8 SCALE IN FEET Designed By. scs Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622-81.30 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Scale: 1 /4" 11 Filename: TK -M 1.03.dwg Contract No.: RTA /CP 0101-05 RECEIVED AUG 162012 PERMIT CENTER 90% PERU T SUBV TTAL Drawing No.: TK -M 1.03 SOU \3 TRANSIT TU <W LA STAT Submitted: Date: No Date Chk. ADD." 06/1 Approved: Date: Date: 06/1 5/1 2 TU <WI LA, WAS \ GTO\ ANCILLARY BUILDING SPRINKLING FIRE 0\ Sheet No.: Rev.: 292 • 3 • 1 1 "NON— POTABLE CW PLAN NOTES Q 1" NON— POTABLE CW UP TO KIOSK NON— FREEZE WALL BOX HYDRANT; SEE DETAIL 4 /TK —M0.03 PARTIAL BELOW GRADE PLAN 1 - MECHAN I CAL SCALE: 1/8" = 1' -0" 1"NON—POTABLE CW 1 TK —M1.00 L KEY PLAN 0 8 16 SCALE IN FEET AS 217 RECEIVED AUG 16 2012 PERMIT CENTER 90% PERv T S „B TTAL Designed By. SCS Drawn By. TMP Checked By DNN No. Date By Chk. App. Revisions Approved By WYL 1E101011f Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 TRES WEST ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 T SOUNDTRANSIT Scale: 8" = Filename: 0” SOU \D TRA \S T TUKWILA STAT O\ TU <WILA, WASH \ GTO\ TK -M I . I I .dwg Contract No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 PARTIAL BELOW GRADE PLAN I — MECHANICAL Drawing No.: TK -M 1. 1 1 Sheet No.: Rev.: 293 • 4 SEE DWG TK -M1.11 • • • 1 1 1 1 1 I 1 1 1 1 1 1 1 • � 1 '-1 "NON— POTABLE CW 1 -1 /2"NON— POTABLE CW V) y 1~ I 6 0 1 1 1 0 0I 1 ELL] (r) PARTIAL BELOW GRADE PLAN 2 - MECHAN I CAL /-1 "NON—POTABLE CW SCALE: 1/8" = 1' -0" TK —M1.00 1 -1 /2 "NON— POTABLE CW PLAN NOTES 0 1" NON— POTABLE CW UP TO .KIOSK NON— FREEZE WALL BOX. HYDRANT; SEE DETAIL 4 /TK —M0.03 oi.rp 1 1 I 1 I .1 0 w w (f) KEY PLAN 4 0 8 SCALE IN FEET 90% PER V Designed By SCS Drawn By TMP Checked By DMM No. Date By Chk. App. Revisions Approved By. WYL MEI Consulting Engineers 1601 fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 TRES WEST ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 Tim SOVNDTRANSIT Scale: 1/8" = 1'_0" Filename: TK -M 1.12.dwg Contract No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 SOU \ D TR A \SIT TU K W LA STAT TU K W LA, WASH\ G TO \ PARTIAL BELOW GRADE PLAN 2 - MECHANICAL 0\ RECEIVED AUG 16 2012 PERMIT CENTER. T SUBMITTAL Drawing No.: TK -M I.. I2 Sheet No.: 294 Rev.: 1-� 1 1 1 1 1 I 1 1 1 1 1 1 1 • � 1 '-1 "NON— POTABLE CW 1 -1 /2"NON— POTABLE CW V) y 1~ I 6 0 1 1 1 0 0I 1 ELL] (r) PARTIAL BELOW GRADE PLAN 2 - MECHAN I CAL /-1 "NON—POTABLE CW SCALE: 1/8" = 1' -0" TK —M1.00 1 -1 /2 "NON— POTABLE CW PLAN NOTES 0 1" NON— POTABLE CW UP TO .KIOSK NON— FREEZE WALL BOX. HYDRANT; SEE DETAIL 4 /TK —M0.03 oi.rp 1 1 I 1 I .1 0 w w (f) KEY PLAN 4 0 8 SCALE IN FEET 90% PER V Designed By SCS Drawn By TMP Checked By DMM No. Date By Chk. App. Revisions Approved By. WYL MEI Consulting Engineers 1601 fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 TRES WEST ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 Tim SOVNDTRANSIT Scale: 1/8" = 1'_0" Filename: TK -M 1.12.dwg Contract No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 SOU \ D TR A \SIT TU K W LA STAT TU K W LA, WASH\ G TO \ PARTIAL BELOW GRADE PLAN 2 - MECHANICAL 0\ RECEIVED AUG 16 2012 PERMIT CENTER. T SUBMITTAL Drawing No.: TK -M I.. I2 Sheet No.: 294 Rev.: • 4 • E F 1 FOR CONTINUATION 1 SEE SHEET TK —M1.02 - 1 1 1 1 1 1 1 N I 1 1 C— 0 1 1 w N , 1 1 1 _1 /2 „NON— POTABLE CW 1 1 1 7 v' CD w uJI CD - - - - - - - �- - -/ ” — CW 1 1 /2 NON POTABLE - - - - 1 -1 2 "NON— POTABLE CW — / - - i 4 I i i - - - - - - - - - --1 1 -1 2 "NON— POTABLE CW J i / / 1 I 1 1 . I L_•1111 1 N1 1 1 1 , 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 -1 /2 „NON— POTABLE CW IN d CASING — SEE TK —UC.05 U L 1 1 1 I 1 1 1 1 1 1 1 1 1 r 1 1 1 i i 1 1 1 1 1 1 O i 1 0 1 1 1 1 I— I L _ _ J 1� 1 CD 1� �1 wl 1 1 -1 /2 NON—POTABLE CW I � 1 -1 /2 "NON— POTABLE CW 1 1 — — — — — — — 11 I I— — — — ., U , RECEIVED rib AUG 16 2012 _ ® IMIIII — PERMIT CENTER NOTES PLAN O 1" NON— POTABLE CW UP TO KIOSK NON— FREEZE WALL BOX HYDRANT, Are PARTIAL BELOW GRADE PLAN 3 - MECHAN I CAL SEE DETAIL 4 /TK —M0.03 KEY PLAN Qi���,�.�� � Z 8 4 0 8 16 =k, ....) SCALE: 1 /8” = 1, -0„ TK— M1.00 SCALE IN FEET 90% PERVIT SURv TTAL Designed B g y, scs Drawn By TMPa- �_ � ' gu G . ov�� ' r � 3 ! rs, • 31308 � �� y [9 ry� ss o 06/1. ��, w w w= t�. Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622-81.30 TRES WEST SOUNDTRANSIT Scale: 1 /s° = II_O1� SOU\D T. PARTIAL TRA K W \S L A, BELOW MECHANICAL T T`,�WILA WASH GRADE STAT \ G T 0\ PLAN 3 — O\ Drawing No.: — TK M I . I3 ENGINEERS ,INC. Filename: Z TK —M 1.1 3.dwg 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 Contract No.: RTA /CP .0 101 -05 Sheet No.: : Rev.. 295 Checked By DMM Submitted: Date: Approved: Date: Date: 06/15/12 Approved By. WYL No. Date By Chk. App. Revisions A •' B • • • •. H 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT UP; CONTINUED ON SHEET TK —M1.14 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT; ROUTE UNDER SLAB ABOVE - -� " 1 NON - POTABLE CW 3" SCHEDULE 80 STAINLESS BICYCLE CAGESTEEL DOWNSPOUT; ROUTE UNDER SLAB ABOVE (SIMILAR) 6 M0.3 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT r- L__ NFBI-1; SEE TK —A2.12 FOR EXACT LOCATION 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT UP; CONTINUED ON SHEET TK -M1.14 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT® 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT; ROUTE UNDER SLAB ABOVE; CIVIL TO CONNECT TO TRENCH DRAIN PIPING, REF. TK —DR.05 /-1"NON—POTABLE CW PARTIAL BELOW GRADE PLAN 4 - MECHAN I CAL SCALE: 1 /8" = 1' -0,, n TK —M1.00 PLAN NOTES 0 1" NON — POTABLE CW UP TO KIOSK NON— FREEZE WALL BOX HYDRANT; SEE DETAIL 4 /TK —M0.03 rilifolow fl fl � fl fl fl fl fl O 0 O 0 O O O 0 O 0 O 0 O 0 O 0 O 0 4KoY PLAN SCALE IN FEET icii9,464,f/4947.1 F 90% ICE R Designed By scs No. Date By Chk. App. Revisions Drawn By TMP Checkod By DMM Approired By WYL Consulting Engineers 1601 'Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Scale: 1/8 = 11 Filename: TK —M I.14.dwg Contract No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 SOU \3 TRA \SIT TU <W LA STAT O\ TU <WILA, WASHI\GTO\ PARTIAL BELOW GRADE PLAN 4 — MECHANICAL RECEIVED AUG 162012 PERMIT CENli Eli. SUB v TTA L Drawing No.: TK -MI.14 Sheet No.: Rev.: 296 • • PLAN NOTES 01 KIOSK NON— FREEZE WALL BOX HYDRANT; SEE DETAIL 4 /TK —M0.03 G =him PIP d •-G• �7i75�[7 PART 1 AL PLATFORM PLAN 1 - MECHAN 1 CAL SCALE: 1 /8" = Designed By. scs Drawn By •TMP Checked By DNN Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622-81.30 T R E S W E S T SOUR 3 ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Approved By WYL No. Date By App. Revisions Submitted: Date: Approved: Date: Filename: TK —M I.2 I .dwg Contract No.: RTA /CP 0101 -05 TRA \SIT T „ '<WILA STAT O\ TJ KW LA, WASH RGTO\ SuBV Drawing No.: TTA L Date: 06/1 0/15/1 2 PARTIAL PLATFORM PLAN I - MECHANICAL Sheet No.: Rev.: 1 1 1 1 1 1 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT 3 _mom1.1 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT 11, r. 1I STAINLESS STEEL DOWNSPOUT 2 EDULE 80 SS STEEL OUT I: 1 1 1 1 1 1 - 3 CHEDULE 80 STA NLESS STEEL DOWNSPOUT O 11 -B� PARTIAL PLATFORM PLAN 2 - MECHAN I CAL SCALE: 1/8" = 1'_0" Date By Chk. App. Revisions 3" SCHEDULE 80 STA NLESS STEEL DOWNSPOUT n Designed By SCS Drawn By TMP Checked By DMM Approved By WYL TK —M 1.00 EMI Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 PLAN NOTES 3 7 1 1 1 3" CHEDULE 80 TAINLESS STEEL KIOSK NON - FREEZE WALL BOX HYDRANT; SEE DETAIL 4 /TK —M0.03 ® DOWNSPOUTS — SEE DETAIL 4 /TK —M1.00 & ARCHITECTURAL DETAILS 8/TK —A8.15 AND 11/TK—A8.15. CONNECT TO STORM DRAINAGE, REF. TK —DR.02 THRU TK —DR.06 SOUNDTRANSIT 11.7 Scale: I /8" Filename: TK —M 1.22.dwg Contract No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 3 • CHEDULE 80 STA NLESS STEEL DOWNSPOUT O ICD Li cri uJ S0 KEY PLAN 0 8 16 i, 90% P SCALE IN FEET 0 RECEIVED AUG 162111` PERMIT CEN \D TRA \S T TUKWILA STAT O\ TUKWILA, WASH \ GTO\ PARTIAL PLATFORM PLAN 2 - MECHANICAL UBV TTAL rowing No.: TK-M 1.22 Sheet No.: Rev.: 298 • F • N • 1 I II Cp I I D 1 w Iw 1 1 1 1 1 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT O 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT O 1 F 1 1 1 1 1 I DIW wl 1 1 PART I AL PLATFORM PLAN 3 MECHAN I CAL SCALE: 1/8" = 1,_0" No. Date Revisions Designed By scs Drawn By • 'IMP Checked By DMM n i 3" SCHEDULE 80 STA NLESS STEEL DOWNSPOUT O 1 TK —M1.00 AMIN Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 3" CHEDULE 80 STAINLESS STEEL DOWNSPOUT O TRES WEST ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 1112.----i 1 7 PLAN NOTES O KIOSK NON— FREEZE WALL BOX HYDRANT; SEE DETAIL 4 /TK —M 0.03 02 DOWNSPOUTS — SEE DETAIL 4 /TK —M1.00 & ARCHITECTURAL DETAILS 8/TK -A8.15 AND 11/TK- A8.15. CONNECT TO STORM DRAINAGE, REF. TK —DR.02 THRU TK —DR.06 SOUNDTRANSIT Approved By. WYL Submitted: Date: Approved: Date: Scale: I /8" = I 1 nll Filename: TK -M I.23.dwg Contract No.: RTA /CP 0101 -05 Date: 06/15/12 SOU SCALE IN FEET 3 TRANSIT T„ T, <WILA STAT NGTO\ <WILA, WAS PARTIAL PLATFORM PLAN 3 - MECHANICAL 0\ RECEIVED AUG 162012 PERMIT CENTER S „B V TTAL Drawing No.: TK -M 1.23 Sheet No.: Rev.: 299 • • • 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT; CONNECT TO GUTTER & SEE SHEET TK —M1.14 FOR CONTINUATION -3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT; CONNECT TO GUTTER & SEE SHEET I TK -M1.14 FOR CONTINUATION 0 3" SCHEDULE 80 STAIN1ESS=ETE€ DOWNSPOUT �E! SPOUT UP TO GUTTER (TK -A2.13 & TK— A7.13). DAYLIGHT TO PLATFORM LEVEL 3 "0 STAINLESS STEEL DOWNSPOUT UP TO GUTTER (TK —A2.13 & TK— A7.13). -DAYLIGHT TO— GRRAADE 3 "0 STAINLESS STEEL DOWNSPOUT UP TO GUTTER (TK —A2.13 & TK— A7.13) & DOWN TO STORM (TK- DR.05) 3" SCHEDULE STAI&ESS —S DOWNSPOUT 3 CHEDULE 80 STAINLESS STEEL rTh TK —M7.00 PLAN NOTES 0 KIOSK NON— FREEZE WALL BOX HYDRANT; SEE DETAIL 4 /TK —M0.03 O DOWNSPOUTS — SEE DETAIL 4 /TK —M1.00 & ARCHITECTURAL DETAILS 8/TK —A8.15 AND 11/TK— A8.15. CONNECT TO STORM DRAINAGE, REF. TK —DR.02 THRU TK -DR.06 03 DAYLIGHT TO TRENCH DRAIN; REF. TK —DR.05 KEY PLAN 0 8 SCALE IN FEET 90% PERV1 UBv TTAL No. Date Revisions Designed By SCS Drawn By TMP Checked By. DMM Approved By. WYL Scale: ellEIN Consulting Engineers 9 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSR Submitted: Date: Approved: Date: Filename: TK— Contract No RTA /CP Date: M I.24.dwg 0101 -05 TRA \'SIT T, KWILA STAT TJ /<WILA, WASH \GTO\ Drawing No.: PARTIAL PLATFORM PLAN 4 - MECHAN I CAL Sheet No.: Rev.: