Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M12-119 - FAIRWAY CENTER
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M12 -119 Fairway Center 14240 Interurban Avenue South RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION F,age # Code Exemption � � �� Brief Explsnatoty Description, Statute /Rule The Privacy Act of 1974 evinces Congress' intent that Personal Information — social security numbers are a private concern. As such, individuals' social security numbers are Social Security Numbers redacted to protect those individuals' privacy pursuant 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. to 5 U.S.C. sec. 552(a), and are also exempt from 552(a); RCW 552(a); RCW disclosure under section 42.56.070(1) of the 42.56.070(1) 42.56.070(1) Washington State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card Personal Information — numbers, electronic check numbers, credit expiration 17 DR2 Financial Information — dates, or bank or other financial account numbers, RCW RCW 42.56.230(4 5) which are exempt from disclosure pursuant to RCW 42.56.230(5) 42.56.230(5), except when disclosure is expressly required by or governed by other law. FAIRWAY CENTER 14240 INTERURBAN AV S M12 -119 City o*Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 3365901881 14240 INTERURBAN AV S TUKW Project Name: FAIRWAY CENTER Permit Number: M12 -119 Issue Date: 09/26/2012 Permit Expires On: 03/25/2013 Owner: Name: Address: Contact Person: Name: Address: Email: BELLTOWN INVESTMENT PARTNER 2505 2ND AVE #520 , SEATTLE WA 98121 HOLLY SAWYER 2502 2 AV STE 520 , TUKWILA WA 98168 HSAWYER @THESCHUSTERGROUP. COM Contractor: Name: PSR -HVAC & MECHANICAL SERVICES Address: PO BOX 27073 , SEATTLE WA 98165 Contractor License No: PSRHVMS924JT Phone: 206 529 -3911 Phone: 206 -367 -2500 Expiration Date: 04/30/2014 DESCRIPTION OF WORK: DISCONNECT AND REMOVE 1 EXISTING CARRIER MODEL 48DJ (10 TON 8.4 EER) ROOFTOP GAS PACK. INSTALL 1 NEW CARRIER MODEL 48HC (10 TON 12 IEER) HIGH EFFICIENCY GAS PACK, ECONOMIZER WITH POWER EXHAUST, NON -FUSED DISCONNECT, RETURN AIR SMOKE DETECTOR, AND FILTER RACK. RE- INSTALL BAS CONTROLLER AND PROVIDE ALL NECESSARY MODIFICATIONS TO ELECTRICAL AND GAS FOR NEW UNIT CONNECTION. Value of Mechanical: $19,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: International Mechanical Code Edition: Date: $416.31 2009 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Print Name: Date: cl� 6/20 ) Z This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -119 Printed: 09 -26 -2012 PERMIT CONDITIONS Permit No. M12-119 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this doc: IMC -4/10 M12 -119 Printed: 09 -26 -2012 project. • 21: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M12 -119 Printed: 09 -26 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TuhwilaWA.gov Mechanical Permit No. tin 19 Project No. Date Application Accepted: 00 7 (( ).- Date Application Expires: v a ( )-' /( 3 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: Tenant Name: 14240 Interurban Ave South ZAtIwu Cect.t-eK PROPERTY OWNER Name: Holly Sawyer Name: The Schuster Group Inc City: Tukwila State: WA Zip: 98168 Address: 2502 2nd Ave Suit 520 Email: hswayer @theschustergroup.com City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Holly Sawyer Address: 2502 2nd Ave Suit 520 City: Tukwila State: WA Zip: 98168 Phone: (206) 529 -3911 Fax: (206) 529 -3901 Email: hswayer @theschustergroup.com King Co Assessor's Tax No.: 3365901881 Suite Number: Floor: Roof New Tenant: ❑ Yes ®..No MECHANICAL CONTRACTOR INFORMATION Company Name: PSR MECHANICAL Address: 3132 NE 133rd Street City: Seattle State: WA Zip: 98125 Phone: (206) 367 -2500 Fax: (206) 368 -6856 Contr Reg No.: PSRHVMS924JT Exp Date: 04/20/2014 Tukwila Business License No.: BUS - 0993498 Valuation of project (contractor's bid price): $ 19,000 Describe the scope of work in detail: Disconnect,and remove 1 existing Carrier Model 48DJ (10 Ton8.4 EER) rooftop gas pack. Install 1 new Carrier Model 48HC (10 Ton 12 IEER) high efficiency gas pack, economizer with power exhaust, non -fused disconnect, return air smoke detector, and filter rack. Re- install BAS controller and provide all necessary modifications to electrical and gas for new unit connection. Use: Residential: New ❑ Commercial: New Fuel Type: Electric ® Gas APPlicm i.cd: Aug..' 21111 Replacement Replacement Other: Gas Heat - Electric A/C I'auelor2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <1 OOk btu Furnace >100k btu Floor furnace Suspended /wall /floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm /industrial Unit Type Qty Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp/ I ,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER UTHOR AGENT: Signature: Print me: Jaso ensen Day Telephone: (206) 367 -2500 Mailing Address: 3132 NE 133rd Street Seattle WA 98125 I I: \,\ pp l ic.n i, •n:lr, n m: Appf.,d i, ni. Date: $47 /Z (h. 1.,,0201 I , \ppli. ai . \ \lu li,wi.al Pay , \p•li.,■i,•,i IA.i,.J 8-9-1 Ldnn City State Zip u.•,•i..•d::\"_g"<t 'l} I Page 2 or 2 hh • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 3365901881 Permit Number: M12 -119 Address: 14240 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 08/27/2012 Applicant: FAIRWAY CENTER Issue Date: Receipt No.: R12 -02464 Payment Amount: $416.31 Initials: LAW Payment Date: 08/27/2012 03:06 PM User ID: 1632 Balance: $0.00 Payee: PSR TRANSACTION LIST: Type Method Descriptio Amount Payment Check 011777 416.31 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 333.05 000.345.830 83.26 Total: $416.31 doc: Receiot -06 Printed: 08 -27 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING. DIVISION: 6300 Southcenter Blvd., #100, Tukwila. WA 98188 l _ (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 (� OD Project: t' 14T R t%J ki CAF NiTc. tZ Type of Inspection: Ottdca Lk .1 -- ► ki/11 Address: 1 L4() :n.IZCRtik,PInsl Al Date Called: J Special Instructions: { Cj Am Yt�� 1 i E, S itt c.1.tE.. $ ld tr j t50- J Date Wanted:. • -3 - i2.- '" `mN p.m: Requester: ,g it c6 Phone No: �e (] CJ A.017 -' (1-55 -3 epS Approved per applicable codes. COMMENTS: Corrections required prior to approval. I (i h !i . to — t rte/ - Y p /o./A L7 D /GN/e v (3) SM© ire. Simic\ APP./ "1-1 ?erm.i- O pte +c lrr •B- Ins:pe ttoor:: Date:. 3 n Rg1 SPECTION FEE REQUIRED. Prior to next inspection, .fee . must be pejdat 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT,NO.. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: l 2vJ'Ay e€ q..r d Type of Inspection: �, ,.J Pi L__. Address: ` '42Un LK!acv'1.k. abvtz..J Date Called: . Special Instructions: Date Wanted:. 10 — Z'i °- 17 fa.m cp.m. Requester: Phone No: (2_0C -7 tc A(.:. • Approved per applicable codes. .D Corrections required prior to,approval. COMMENTS: 1) -- -12 c:./r1 L — NicE Is ti--) SM : AA, S to - . z X L A) --•4&•zz.s,te Inspector: Date: t j n REINSPECTION FEE EQUIRED. Pfior to next inspection. fee must -be Laid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.` INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 177 — 119 /3 - v3J PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: tom, *■-4,4 y cc,, h,.,... ,,.• a Type of Inspection: cAl . /-7',-..,/ Sn.-�� 5--2.+:4 Jp•i, Address: / '-/2 -'a Suite #: 7 4 s- Contact Person: ft,. r..41 •c.e. /°i4 s c (.._. Special Instructions: i.} ;I0/.9x15 4=s4 S. ,A, i - Phone No.:. 70e- 3 z "- 3 .Z $fr Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Se -s s 4‘..)4),,e, ‘ ÷.., pot,, -c I °sC, `J` 2.) •2rrr rte,.ter,,1,, / ...e_ - , i.} ;I0/.9x15 4=s4 S. ,A, i - �1 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: - Occupancy Type: Inspector: ,t"Nj $3 Date: 3 /'21' 3 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 . T.F.D. Form F.P. 113 CWA CONSULTANTS, P.S. STRUCTURAL ENGINEERING BUILDING CODE CONSULTANTS FILE COPY 8675 E. Caraway Road, Port Orchard, WA 98366 (360) 871 -5433 FAX: (360) 871 -5633 E-Mail: chuck@cwaconsultants.net August 22, 2012 HVAC Roof Attachment PSR HVAC and Mechanical Services Fairway Center Seattle, WA Fp= c0_._4apx5_D5)(1 +2z /J1)_ Wp Rp /Ip ASCE 7 Table 13.6 -1 ap =2.5, Rp =6.0 SPs = 0.846 z/h =1.0 max Connect new metal curb of HVAC unit to existing wood framing #12 screws (4 min) @ 24" oc at perimeter Connect HVAC unit to curb per manufacturer's installation instruction Fp = (0_._4x250_.8 6x3.0_). Wp = 0.423 Wp 6.0/1.0 Fp max = 1.6x0.846 =1.35 Fp min = 0.3x0.846 = 0.25 Use 0.423 Wp Fp @CG I, 4x8 at curb support with BA48 top flange hanger each end Existing 13" TJI Type Roof Joists Existing 8 -3/4 "x36" Glu -Lam HVAC Unit — Wt =1550# total including curb L = 88" W = 53" H = 49" Cg = 24" above base Fp = 0.423x1550 = 656# Wind X = .85x1.3x(4.0x7.0)(13) = 402# Wind Y = .85x1.3x(4.0x5.0)(13) =172# USE 656# for all calcs OT (worst case) = 656x24 — 0.6x1550 x30 = - 12,156 "# no net overturning Attachment R V''''�►! .• bPO1ti CODAPPR` load SEP 0 7 2012 City of Tukwila BUILDING DIVISION n to existing wood framing- #12 Wood screws )# x 4 (min) = 832# min > 656# OK 1193/4 = 298# R: \Documents \Word Files\PSR \PSR Fairway Center HVAC Installation.doc cmTUIV4UA AUG 2 7 2012 PERMIT CENTER M1H�� 1 -1 • ri St, cg ■•• c7 Z: vvi 03 -05 -2013 HOLLY SAWYER 2502 2 AV STE 520 TUKWILA WA 98168 .11.1 Haggerton; =11%Iaypr• ephrtmentof Communaty= Developmer JcrckPcrce Director: RE: Permit No. M12 -119 FAIRWAY CENTER 14240 INTERURBAN AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 04/22/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 04/22/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, r Marshall Technician File: Permit File No. M12 -1 19 630 . Southcenter Boulevard; Suite #100'- Tukwila, Washington 98188 • Pho ze 20 431 3670 Fax '31 3663' •PERMIT COORD COPS, PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -119 PROJECT NAME: FAIRWAY CENTER SITE ADDRESS: 14240 INTERURBAN AV S DATE: 08/27/12 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued EPARTMENTS: /AT A1!tt r Building Division Public Works 8 -30"a, ire Prev" ention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ,K Incomplete I I DUE DATE: 08/28/12 Not Applicable ❑ Comments: Permit ' Center' Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: DUE DATE: 09/25/12 REVIEWER'S INITIALS: DATE: =Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople Pr, ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company PSR -HVAC Et MECHANICAL SERVICES 2063672500 Po Box 27073 Seattle WA 98165 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602811195 Active PSRHVMS924JT Construction Contractor 4/30/2008 4/30/2014 General Unused se License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status PUGETI.261CG PUGET SOUND REFRIGERATION INC Construction Contractor Air Conditioning Commercial /Industrial /Refrig2 /7/1974 2/1/1984 Archived PUGETSR169CB PUGET SOUND REFRIGERATION INC Construction Contractor General Unused 2/2/1984 12/31/2008 Inactive PSR****936JP PSR Construction Contractor General Unused 4/17/2007 /2008 Re- Re- Licensed Business Owner Information Name Role Effective Date Expiration Date O'MALLEY, JAMES J Member 04/30/2008 Amount HOGERTY, REAGAN P Member 04/30/2008 GL0488649702 O'DONNELL, STEPHEN 0 04/01 /2013 04/30/2008 04/12/2012 RIST, STEVEN L 04/05/2012 04/30/2008 04/12/2012 Bond Information No records found for the previous 6 year period Assignment of Savings Information Page 1 of 2 Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 4/30/2008 Until Released Bond $12,000.00 4/30/2008 Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 Zurich American Ins Co GL0488649702 04/01 /2012 04/01 /2013 $1,000,000.00 04/05/2012 5 Zurich American Ins Co GL0488649701 04/01/2011 04/01/2012 $1,000,000.00 04/04/2011 4 ZURICH AMERICAN INS CO GL0488649700 04/01/2010 04/01/2011 $1,000,000.0004 /05/2010 3 HARTFORD CAS INS CO 37UUNN03345 04/01/2009 04/01/2010 $1,000,000.0003 /31/2009 2 HARTFORD FIRE INS CO 37UUNN03345 06/01/2008 06/01/2009 $1,000,000.00 06/06/2008 https: // fortress .wa.gov /lni/bbip/Print.aspx 09/26/2012 SITE VICINITY NTS SITE INFO ADDRESS: OWNER: PARCEL /TAX # LEGAL: 14240 INTERURBAN AVE. S. TUKWILA, WA 98168 BELLTOWN INVESTMENT PARTNER 3365901881 HILLMANS SEATTLE GARDEN TRS POR OF LOT 1 & ALL OF LOTS 2 THRU 7 & POR ADJ IN SE 1/4 OF SECTION 14 -23 -04 DAF - BEG SE COR OF SAID LOT 7 TH NLY ALG ELY LN 315 FT TO LFT BANK OF DUWAMISH RIVER AS ORIGINALLY PLATTED TH CONTC ON NLY PROD OF SD ELY 220 FT M/L TO LFT BANK AS EXISTED UNDER SUPERIOR COURT CAUSE NO 81 -2- 05910 -4 TH WLY ALG SD BANK TO AN INTSN WITH NELY PROD OF SELY LN OF NWLY 72 FT OF SD LOT 1 TH SWLY ALG SD LN PROD 200 FT M/L TO LFT BANK OF DUWAMISH RIVER AS PLATTED IN ORIGINAL PLAT TH CONTG IN SWLY DIRECTION ALG SELY LN OF NWLY 72 FT OF SD LOT 1 DISTANCE OF 55 FT M/L TO SWLY LN OF SD LOT 1 TH SELY ALG SD LN TO INTSN WITH N MGN OF S 143RD ST FIRST AVE TH ELY ALG SD MGN TO TPOB -TGW POR FOSTER JOSEPH DC #39 BEING POR OF ABANDONED PUGET SOUND ELECTRIC RR R/W IN THE SW 1/4 OF SE 1/4 OF SD SEC 14 SD RR R/W BOUNDED ON NE BY MAULE AVE ON SW BY A LN 20 FT NE OF & PLT NELY MGN OF SR 181 UNDER REC #8905231113 ON THE SE BY R/W #5 & ON THE NW BY R/W #6 BOTH R/W DEFINED IN QCD AUD FILE # 6557639 - TGW VAC MAULE AVE ADJ TGW POR VAC ST ADJ EY PLA\ SCALE NOTE: j 2009 WASHINGTON STATE ENERGY CODE NOTES GENERAL NOTES 1411.1: EQUIPMENT SHALL HAVE A MINIMUM PERFORMANCE AT THE SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES SHOWN IN TABLES 14 -1A THROUGH 14-10. 1411.4: PACKAGED ELECTRICAL EQUIPMENT PROVIDING BOTH HEATING AND COOLING WITH A TOTAL COOLING CAPACITY GREATER THAN 20,000 BTU /H SHALL BE A HEAT PUMP. 1412.1: EACH SYSTEM SHALL BE PROVIDED WITH AT LEAST ONE TEMPERATURE CONTROL DEVICE. EACH ZONE SHALL BE CONTROLLED BY INDIVIDUAL THERMOSTATIC CONTROL RESPONDING TO TEMPERATURE WITHIN THE ZONE. AT A MINIMUM, EACH FLOOR OF A BUILDING SHALL BE CONSIDERED AS A SEPARATE ZONE. 1412.4: HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF ACCOMPLISHING A REDUCTION IN OF ENERGY USE THROUGH CONTROL SETBACK OR EQUIPMENT SHUTDOWN DURING PERIODS OF NON -USE OR ALTERNATE USE OF THE SPACES SERVED BY THE SYSTEM. 1412.4.1: OUTSIDE AIR INTAKES, EXHAUST OUTLETS AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH MOTORIZED DAMPERS WHICH CLOSE AUTOMATTICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE. STAIR SHAFT AND ELEVATOR SHAFT SMOKE RELIEF DAMPERS SHALL REMAIN CLOSED UNTIL ACTIVATED BY SMOKE DETECTION SYSTEM. DAMPERS INSTALLED TO COMPLY WITH THIS SECTION, INCLUDING DAMPER INTEGRAL TO HVAC EQUIPMENT, SHALL HAVE A MAXIMUM LEAKAGE REATE WHEN TESTED IN ACCORDANCE WITH AMCA STANDARD 500 OF: A. MOTORIZED DAMPERS: 10 CFM /SQ. FT. OF DAMPER AREA AT 1.0 IN. W.G. B. NONMOTORIZED DAMPERS: 20 CFM/ SQ. FT. OF DAMPER AREA AT 1.0 INCH W.G., EXCEPT THAT FOR NONMOTORIZED DAMPER SMALLER THAN 24 INCHES IN EITHER DIMENSION: 40 CFM/ SQ.FT. OF DAMPER AREA AT 1.0 INCH W.G. 1412.4.1.1: DAMPERS FOR OUTDOOR AIR SUPPLY AND EXHAUST SHALL AUTOMATICALLY SHUT WHEN THE SYSTEM IS NOT IN USE OR DURING BUILDING WARM -UP COOLDOWN AND SETBACK. 1412.5: UNITARY AIR COOLED HEAT PUMPS SHALL INCLUDE MICROPROCESSOR CONTROLS THAT MINIMIZE SUPPLEMENTAL HEAT USAGE DURING START -UP, SET -UP AND DEFROST CONDITIONS. 1412.7: EACH AIR SUPPLY OUTLET OR AIR OR WATER TERMINAL DEVICE SHALL HAVE MEANS FOR BALANCING, INCLUDING BUT NOT LIMITED TO, DAMPERS, TEMPERATURE AND PRESSURE TEST CONNECTIONS AND BALANCING VALVES. 1413.1: AIR ECONOMIZERS SHALL BE CAPABLE OF AUTOMATICALLY MODULATING OUTSIDE AND RETURN AIR DAMPERS TO PROVIDE 100% OF THE DESIGN SUPPLY AIR AS OUTSIDE AIR TO REDUCE OR ELIMINATE THE NEED FOR MECHANICAL COOLING. 1413.3: AIR AND WATER ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET THE COOLING LOAD. 1414.1: DUCTWORK (OTHER THAN ROUND OR FLAT OVAL) WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED. 1414.1.2: ALL LOW PRESSURE DUCT SYSTEMS SHALL BE SEALED TO A LEAKAGE RATE NOT TO EXCEED 6% OF THE FAN FLOW IF THE DUCT SYSTEM HAS MORE THAN 25% DUCT SURFACE AREA LOCATED IN ANY UNCONDITIONED SPACE. THE LEAKAGE RATE SHALL BE CONFIRMED THROUGH FIELD VERIFICATION AND DIAGNOSTIC TESTING, IN ACCORDANCE WITH SMACNA DUCT LEAKAGE TEST PROCEDURES - 1985. 1414.1.3: DUCT WORK DESIGNED TO OPERATE IN EXCESS OF 3" WATER COLUMN SHALL BE LEAK TESTED IN ACCORDANCE WITH SMACNA DUCT LEAKAGE TEST PROCEDURES - 1985. 1414.2: INSULATION OF SUPPLY, RETURN AND OUTSIDE AIR DUCTWORK SHALL MEET THE REQUIREMENTS OF CHAPTER 13, DAMPERS SHALL COMPLY WITH SECTION 1412.4.1 BE INSULATED IN ACCORDANCE WITH TABLE 14 -5. 1416.2.1: BUILDINGS WHICH REQUIRE A COMMISSIONING PROCESS IN ACCORDANCE WITH WSEC SECTION 1416 AND SHALL INCLUDE: 1. COMMISSIONING PLAN 2. SYSTEMS TESTING AND BALANCING 3. HVAC EQUIPMENT AND CONTROLS FUNCTIONAL TESTING REVIEWED FOR CODE COMPLIANCE APPROVED 4. SUPPORTING DOCUMENTATION IN THE FORM OF OPERATION AND MAINTENANCE AND RECORD DOCUMENTS 5. COMMISSIONING REPORT. SEP 07 2012 City of BUILDIN 1416.3.3: ALL HVAC SYSTEMS, EQUIPMENT AND CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH SEQUENCES OF OPERATION PRESCRIBED IN THE CONSTRUCTION DOCUMENTS. WRITTEN PROCEDURES WHICH CLEARLY DESCRIBE THE INDIVIDUAL SYSTEMATIC TEST PROCEDURES, THE EXPECTED SYSTEMS' RESPONSE OR ACCEPTANCE CRITERIA FOR EACH PROCEDURE, THE ACTUAL RESPONSE OR FINDINGS, AND ANY PERTINENT DISCUSSION 1416.3.4.2: TRAINING OF THE MAINTENANCE STAFF FOR EACH EQUIPMENT TYPE AND /OR SYSTEM SHALL INCLUDE AS A MINIMUM: 1. REVIEW OF SYSTEM DOCUMENTATION. 2. HANDS -ON DEMONSTRATION OF ALL NORMAL MAINTENANCE PROCEDURES, NORMAL OPERATING MODES, AND ALL EMERGENCY SHUTDOWN AND START -UP PROCEDURES. 3. TRAINING COMPLETION REPORT. 1416.3.5: THE COMMISSIONING REPORT SHALL BE COMPLETED AND PROVIDED TO THE OWNER. THE COMMISSIONING REPORT SHALL INCLUDE: 1: COMPLETED FUNCTIONAL TEST FORMS INCLUDING MEASURABLE CRITERIA FOR TEST ACCEPTANCE. 2: ISSUES LOG OF CORRECTED AND UNCORRECTED DEFICIENCIES WITH THE ANTICIPATED DATE OF CORRECTION. 3: DEFERRED TESTS, WHICH CANNOT BE PERFORMED AT THE TIME OF REPORT PREPARATION, WITH ANTICIPATED DATE OF COMPLETION. 4: RECORD OR PROGRESS AND COMPLETION OF OPERATOR TRAINING. 5: COMPLETED COMMISSIONING COMPLIANCE FORM. 1416.4: A COMMISSIONING COMPLIANCE CHECKLIST SHALL BE SUBMITTED TO THE BUILDING OFFICIAL UPON SUBSTANTIAL •. COMPLETION OF THE BUILDING. THE CHECKLIST SHALL BE COMPLETED AND SIGNED BY THE BUILDING OWNER OR OWNER'S REPRESENTATIVE. COMPLETION OF THE COMMISSIONING COMPLIANCE CHECKLIST IS DEEMED TO SATISFY THIS REQUIREMENT. 1432.2.1: AIR SYSTEMS SERVING MULTIPLE ZONES SHALL HAVE CONTROLS TO AUTOMATICALLY RESET SUPPLY AIR TEMPERATURE BY REPRESENTATIVE BUILDING LOADS OR OUTSIDE AIR TEMPERATURE. 1435: SYSTEMS WHICH PROVIDE HEATING AND COOLING TO THE SAME ZONE SIMULTANEOUSLY ARE PROHIBITED EXCEPT AS NOTED IN SECTION 1435. 1437: THREE PHASE ELECTRIC MOTORS NOT INCLUDED IN EQUIPMENT EFFICIENCY RATINGS (LE., EXHAUST FANS, PUMPS, COOLING TOWER FANS) SHALL MEET MINIMUM EFFICIENCY RATINGS LISTED IN WSEC TABLE 14 -4A & B. la ISION PROTECT ALL DUCT OPENINGS OF FIRE RATED ASSEMBLIES PER I.B.C. 716. INSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF SHAFT ENCLOSURES PER I.B.C. SECTION 707. INSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF FIRE PARTITIONS, FIRE WALLS, FIRE BARRIERS AND SMOKE PARTITIONS PER I.B.C. CHAPTER 7. ALL FIRE DAMPERS SHALL BE DYNAMIC TYPE, U.L. 555 RATED. ALL CEILING RADIATION DAMPERS SHALL BE U.L. 555C RATED. ALL COMBINATION SMOKE FIRE DAMPERS SHALL 3E U.L. 555S RATED. NSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING PER I.B.C. EQUIREMENTS. INSTALL ALL PIPING ON ROOM SIDE OF BUILDING INSULATION. MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND DO NOT NECESSARILY REFLECT EVERY REQUIRED OFF -SET, FITTING OR ACCESSORY. COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING STRUCTURE AND ALL OTHER TRADES. THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS, PIPES, UTILITIES AND BUILDING STRUCTURE. VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. ALL MECHANICAL EQUIPMENT LOCATED IN CEILING CAVITIES THAT REQUIRE ELECTRICAL CONNECTION SHALL HAVE AN 8 -1/2 "x11" LAMINATED SIGN PERMANENTLY MOUNTED ON THE ELECTRICAL ENCLOSURES THAT INDICATES: "THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36" (LESS THAN 460V) AND 42" (460V AND ABOVE) ". NO TRADE SHALL BLOCK THIS SPACE EVEN IF SHOWN ON THE DRAWINGS. INSTALL SIGN PRIOR TO INSTALLATION OF EQUIPMENT. ALL MECHANICAL EQUIPMENT THAT REQUIRES ACCESS FOR COIL PULL, FILTER CHANGE, MOTOR CHANGE, COMPRESSOR CHANGE, LUBRICATION, SHEAVE AND BELT CHANGE, FAN CHANGE OUT, ETC. SHALL' HAVE AN 8 -1/2 "x11" LAMINATED SIGN PERMANENTLY MOUNTED ON THE EQUIPMENT ACCESS PANELS THAT INDICATES "THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36 ". NO TRADE SHALL BLOCK THIS SPACE. AREA OF WORK SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical ok Electrical Plumbing 'Gas Piping f Tukwila F ' ' DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional pan review fees. LEGEND PA1 [20051 129ft2 SUPPLY DIFFUSER RETURN GRILLE EXHAUST FAN VOLUME DAMPER CAP FLEX DUCT DIRECTION OF AIRFLOW THERMOSTAT POINT OF CONNECTION DEMO MOTORIZED DAMPER FIRE DAMPER ROOM NUMBER AREA OF ROOM TYPE AND NOTE [R] = RELOCATED [N] = NEW [E] = EXISTING - SIZE CUBIC FEET PER MINUTE 1 RAG 12x2 FALE C PY Permit No. Plan review approval is subject to errors and omissions. 1. r rov►al of construction documents does not authorize Mc violation of any adopted code or ordinance. Recent of approved Field Copy and conditions is acknowledged: v Date: City Of Tukwila BUILDING DIVISION NOTE: [1] PROVIDE RUN -OUT DUCT AND FLEXIBLE CONNECTION SAME SIZE AS DIFFUSER NECK DIAMETER. (FIELD VERIFY BEST LOCATION) REt tiv D CITY OF TUKWILA AUG 272012 PERMIT CENTER �t12 -III 3132 N.E. 133 ST Seattle, Washington 98125 -4423 PO Box 27073 Seattle, Washington 98165 -1473 (206) 367-2500 Fax (206) 368 -6856 PSRHVMS924JT 1 oz Z W o 00 W z wo J Q Z Q I-- F- LU Wz Z I_L_ W F-- • LL O 0 00 0 0 (9 W (/) U (/) 0 LL 0 0 m w w z i- 0 w z w z w 1- N TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. 1 General Notes 1. 11 "x17" SHEET SIZE NTS. PERMIT SET 8/2/12 Revision/Issue Date, Project P4735 Sheet Project Manager N. SINGER M 0.0 Scale VARIES SITE IV AP • / • • / • / / • • /\ 1 /32" =1' • i i 1 i 1 1 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 7 2012 City of Tukwila BUILDING DIVISION MI.1%-- 119 Rr tV )., CITY OF TUKVVILA AUG 2 7 2012 PERMIT CENTER 3132 N.E. 133 ST Seattle, Washington 98125 -4423 PO Box 27073 Seattle, Washington 98165 -1473 (206) 367-2500 Fax (206) 368 -6856 PSRHVMS924JT ■ z w U w z 0 w LL W I- z D 0 0 LL 0 0 FOR SCHUSTER GROUP 1- 0 W Z W m cc w 1— z 0 CV d' TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. P General Notes 1 1. 11"x17" SHEET SIZE NTS. 2 AUGUST 2012 Lead Tech Engineered By Date N. SINGER 1 PERMIT SET 82/12 `O. Revision/Issue Date, Drawn By P. GOTO 2 AUGUST 2012 Lead Tech Engineered By Date Project P4735 Sheet Project Manager N. SINGER M 0.1 Scale tI /32 " =1'0" i DEMO NOTES 1) DISCONNECT ELECTRICAL 2) REMOVE UNIT B -5 FROM REGULATIONS. ROOF DEN 0 PLAN 1 /16" =1' FROM UNIT ROOF AND B -5 AND DISPOSE MAKE SAFE. OF UNIT PER EPA Ili RECEIVED CIw OF TUIMn1A AUG 2 7 2012 PERMIT CENTER i 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165 -1473 (206) 367-2500 Fax (206) 368 -6856 PSRHVMS924JT z W 2U W z Q U J Q r J EL! O W W F- a Z LL D OCL O0 u_ 0 0 L.L FOR SCHUSTER GROUP co z 5 ce- w H Z w U u_ I- D 0 w Z w Z m w Z N •f' TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANTTO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. r General Notes 1 1. 11"x17" SHEET SIZE NTS. Date 2 AUGUST 2012 Lead Tech Engineered By Date 1 PERMIT SET 8/2/12 `Nod Revision/Issue D Drawn By P. GOTO Date 2 AUGUST 2012 Lead Tech Engineered By Date Project P4735 Project Manager N. SINGER Scale 1/16"=1'0" Sheet M 1.0 I HVAC NOTES 1) INSTALL 1 NEW 10 TON ROOFTOP UNIT ON EXISTING ROOF CURB, USING EXISTING ROOF PENETRATIONS. 2) SECURE NEW UNIT TO ROOF CURB WITH SHEET METAL SCREWS. 3) CONNECT ELECTRICAL AND CONTROL WIRING. PACKAGED AC ECOMMENT SCHEDULE Sheet Project Manager N. SINGER M 2.0 Scale 1 PERMIT SET 8/2/12 `No. Revision/issue Date) LOCATION ]' COXING GAS FEAT ? ELECTRIC OPERATING BASIS OF SERVES R NOMINAL TONS TOTAL CFM - OSA CFM ECON CYCLE SP WIMP TOTAL SE INPUT HEATING RISE , C a _ VOLTAGEIPHASEI MCA CP PS Lbs. MANWACTIETER MODEL 10 . 100% 1.2 119.85 92.51 12 180 148 4,01M 87 48013 27 1.308 , - 48HCOD1182A6-6131.10 { 214 Floor Area UNIT MOUNTED SMOKE DETECTOR B -1 1 B -6 1 B -4 1 B -5 ROOF HVAC PLAN 1/16"=1' REVIEWE CODE COMPLIANCE APPROVED SEP 0 7 2012 City of Tukwila BUILDING DIVISION REGEIV E° CITY OF TUKWILA AUG 2 7 2012 PERMIT CENTER I 3132 N.E. 133 ST Seattle, Washington 98125 -4423 PO Box 27073 Seattle, Washington 98165 -1473 (206) 367-2500 Fax (206) 368 -6856 PSRHVMS924JT 1 H- z w zO QQ ri 0_ 0w =z u 0 E NOp u_ 0 0 U z FOR SCHUSTER GROUP Z W J 5 Z W Q W Z Z m U 0 > a <w >~ Z Q L N d' TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. r General Notes 1 1. 11"x17" SHEET SIZE NTS. Sheet Project Manager N. SINGER M 2.0 Scale 1 PERMIT SET 8/2/12 `No. Revision/issue Date) Drawn By P. GOTO Date 2 AUGUST 2012 Date Lead Tech Engineered By Project P4735 Sheet Project Manager N. SINGER M 2.0 Scale 1/16 " =1' 27 EXISTING 3'6" PARAPET B -5 6" 16' 15-6" EXISTING 3'6" PARAPET EXISTING ROOF' EXIS11NG ROOF EX STING ROOF CURB I 29' 24' -1" \ORTH ELEVATION 3/32 " =1' B -5 29' -1" 24' a a3 EXISTING ROOF EXIS11NG GRADE' EXISTING 3'6" PARAPET EXISTING ROOF CURB REVIEWED FOR CODE COMPLIANC APPROVED SEP 0 7 2012 City of Tukwila BUILDING DIVISIOI'I� EXISTING 3'6" PARAPET fl i EXISTING ROOF' L J. WEST ELEVATION 3/32 " =1' EXISTING GRADE' 15' -6" 27' -6" 16' RECEIVED CITY OF TUKWILJA AUG 2 7 2012 PERMIT CENTER r 3132 N.E. 133 ST Seattle, Washington 98125 -4423 PO Box 27073 Seattle, Washington 98165 -1473 (206) 367-2500 Fax (206) 368 -6856 PSRHVMS924JT z w 2 U wz U Q z J w < 1- wz w0_ 0 u_ 0 0 FOR SCHUSTER GROUP FAIRWAY CENTER, BUILDING B 14240 INTERURBAN AVENUE SOUTH TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. General Notes ‘ 1. 11 "x17" SHEET SIZE NTS. Date 2AUGUT2012 Lead Tech Engineered By Date 1 PERMIT SET 8/2/12 `No. Revisionlissue Date f Drawn By P. GOTO Date 2AUGUT2012 Lead Tech Engineered By Date Project P4735 Project Manager N. SINGER 3/32 " =1'0" Scale Sheet ] M 3.0