Loading...
HomeMy WebLinkAboutPermit M12-122 - WESTFIELD SOUTHCENTER MALL - MUCHO BURRITOMUCHO BURRITO 971 S OUTh CENTER MALL M12 -122 City oftukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 971 SOUTHCENTER MALL TUKW Project Name: MUCHO BURRITO Permit Number: M12 -122 Issue Date: 09/10/2012 Permit Expires On: 03/09/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: JAK MOROSHAN Phone: 714 697 -4354 Address: 16125 JUANITA WOODINVILLE WY NE #702 , BOTHELL WA 98011 Email: Contractor: Name: MODCO DESIGN LLC Phone: 716 697 -4354 Address: 16125 JUANITA WOODINVILLE WY #702 , BOTHELL, WA 98011 Contractor License No: MODCODL895LT Expiration Date: 06/30/2013 DESCRIPTION OF WORK: INSTALL WALK IN COOLER Value of Mechanical: $800.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $176.56 International Mechanical Code Edition: 2009 Date:` I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not pres construction or the performance of wor back of this permit. Signature: Print Name: e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: / — m ^ Z°/ t"-- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12-122 Printed: 09 -10 -2012 • • PERMIT CONDITIONS Permit No. M12-122 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional m responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ** *FIRE DEPARTMENT CONDITIONS * ** 8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 9: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinlder heads. (IFC 901.4)(EXTEND SPRINKLER PROTECTION TO WALK -IN FREEZER.) 10: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 11: All new sprinlder systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 12: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 13: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 14: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M12 -122 Printed: 09 -10 -2012 CITY OF TUKT:44 Community Develop Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup:/,`www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: Tenant Name: 7f 5aevL— AA4\ urr King Co Assessor's Tax No.: 12A241 IX fro Suite Number: 15G Floor: IS pROpERTY:OWNER:, \t‘i (),C7k- (A4 Address: Q0 97,0\4, p201 1,0 State: Net Zip: oing Name: City: CAA V4 CONTACT PERSON - person receiving alypitje4;. • • „. Name: Address:, ')‘0 /d C0 City: State: Phone: --ify .c9 7_ Li 35 iF'ax: Email: Jot IL 1/IA040065o Cp0,-■ New Tenant: El Yes LI.. No MECHANICAL CONTRACTOR 1TJFORMAI1ON , Company Name: )Lk 0 01 (1) Ops 91/\ Address: City: fittstz _go jley State: 6.)4 Zip: wae/ Phone: 7 y.351ax: Reg No.: Dolsc_Exp Date://,3 Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: `,-1,-S,. ILe-N Ccp ter. CO c>" y Use: Fuel Type: Residential: New 0 Replacement 0 Commercial: New 0 Replacement 0 Electric El Gas Li Other: H:\Applications\Forms-Applications On Linek2011 Applications \Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type.' Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended /wall /floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty.: Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial • ' Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler /Compressor'•: ' Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 11T ORIZED AGENT: Signature: �/ Date: Print Name: . .� 4 /� s � Day Telephone: �`� � �' %�- y35 Mailing Address: 4 5 2ci2 City H:Wpplications\Forms- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT ParcelNo.: 9202470010 Permit Number: M12 -122 Address: 971 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 08/31/2012 Applicant: MUCHO BURRITO Issue Date: Receipt No.: R12 -02506 Payment Amount: $176.56 Initials: JEM Payment Date: 08/31/2012 09:35 AM User ID: 1165 Balance: $0.00 Payee: JACOB MOROSHAN, MODCO TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 833458 ACCOUNT ITEM LIST: Description 176.56 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 141.25 000.345.830 35.31 Total: $176.56 doc: Receipt -06 Printed: 08 -31 -2012 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188+ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 /1'7/2 -J Z Project: ,47 2 /(7/-/ e) fl/I2t /iU Type of Inspection: ----:2-11/19Z. Address: Gil i S°U e4A /7- /l1 / 9%/ Date Called: Special Instructions: Date Wanted:. 9-27-12 a.m., Requester: C - 29 Phone No: 7iy 6C 4-/$54/ ©Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: (;:t>miZrie//:;,;PV I spectioo E /SPECTION FEE R QUIRED a 7i�r . Pr or to next inspection. fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit P112- Z INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 l- •2(206).431 - 3.670 Permit Inspection Request Line (206) 431 -2451 Project: ,vi/e7 ►> o /3 2/n gi i (� Type of Inspection: ,<d.17V 4 C., Address: G7/ S'd Cz,rr /' /I' Date Called: Special Instructions: Date Wanted:. a'.m' Requester: Phone No: 7/4-- G 5`7 - - `13:5 q ❑ Approved per applicable codes. COMMENTS: Nel ,0c44 Corrections required prior to approval. Innspec o .. / Date: C_. 7 REINSPECTION FEE EQUIRED. Prior to next inspection.. fee must be at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451, Project: X1.1ur1;U 3Li(2TUio Type of Inspection: k 7 2Aw -sar.1 Address: q 7 f 921-1? R_Il C� Date Called: Special Instructions: • anted:. Date Wanted: r a /, m: Requester: Phone No: 7114 - (57- L-1-557V , Approved per applicable codes. D Corrections required prior to approval. COMMENTS: l specro REIhSPECTION FEE REQUIRED. Priorito next inspection; fee must be pad at 6300 Southcenter Blvd.. Suite 100. Callao schedule reinspection. Date:, L1-2 I —i7 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: 410cha coy,', ,) Type of Inspection: P';',-- I ,- 6o J 5 . Address: 92/ �‘'�44.4a° Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: • ,- V .5,(, raicji,i 4)da, --)1 •4v, Cool. it. 6,-) j� I3 fl a4,0C6b4/i..6 G %d ,5_9,1 -vP rl cf ` s Pre -Fire: Permits: Occupancy Type: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: fin ; Date: V z 7/s Hrs.: / IV„ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: 1 Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 7 2012 City of Tukwila BUILDING DIVISION Item Qty (; Kl A. N Quote Date 7/12/2012 Project: From: Mucho Burrito -South Center Food Smith & Greene Company Court Tom Olsen 19015 66th Ave. South FILECOPY Kent WA 98032 -1154 C (425) 988 -6632 (Phone) (425) 681 -3851 (Cell) Perot Description Sell Sell Total 'vmMSM . eo 4960aVCa...,.q.aw .a ...rwmnw s..e.+.n s.xaawa+.+i.ea.tw -. w. ..s.aaawawr., ,e<mr.aw a. ..,r ,xM •.< 11 1 ea WALK IN COOLER, MODULAR, SELF - CONTAINED Nor -Lake Model No. KLB7768 -C Packed: ea Kold LockerTM, Indoor +35 °F Cooler, 6'x 8'x 7' -7 "H, with floor, 26 gauge embossed coated steel interior & exterior finish, self - closing door, locking deadbolt handle, Capsule -Pak ceiling mt., 5 /8hp, 115v/60/1, same day shipment 1 ea Fifteen year original equipment panel warranty 1 ea 5 Yr compressor warranty (net) 1 ea Door hinged on right Weight: 1177 Ibs total iiY?�]4aYF'F1Ya6Y�AiY�'L' $5,912.42 $5,912.42 $79.07 $79.07 ITEM TOTAL: $5,991.49 24 1 ea HOOD SYSTEM Captive Aire Model No. 5430ND 2 PSf' F lacked: e fans and electrical system. $9,722.39 $9,722.3 Acceptance: Printed Name: Mucho Burrito -South Center Food Court freight Tax (9.5 %) Total Date: $15,713.88 $1,683.71 $1,652.77 $19,050.36 RECEIVED ., CITY OF TUKWIA AUG 312012 PERMIT CENTER M1Z I22 Nor -Lake NOR -LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 KLB7768 -C 800 - 955 -5253 715 -386 -2323 800 - 388 -5253 Parts 715 -386 -4291 FAX www.norlake.com KOLD LOCKERTM WALK -INS NORLAKE O 0 9 ✓/'�ti O 0 0 �./�` O 0 0 �/ O 0 O 0 a 0 ✓ 0 O 0 Item #:11 O 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 Standard Model Coolers, Freezers and Combination Cooler /Freezers In Stock for SAME DAY SHIPMENT STANDARD FEATURES • STANDARD MODELS SHIP THE SAME DAY* • Coolers, freezers and combination cooler / freezers • Sizes from 3'6" x 6' to 8' x 20' • Three heights: 67" & 7'7" with floor; 7'4" floorless • Indoor or outdoor models • Three temperatures: +35 °F., - 10 °F., - 20 °F( -20 °F 10 day ship). • Capsule PakTM' refrigeration system (ceiling or wall mount) • Air - cooled condensing unit (wall mount 10 day ship) • Automatic condensate vaporizer. No drain line required on indoor units • Time clock provided for automatic defrost on both coolers and freezers. • 26 gauge corrosion resistant stucco embossed temper passed coated steel on all surfaces except interior floor • Smooth aluminum interior floor (on models with floor) • Floorless models supplied with NSF listed vinyl sealers • Full 4" thick panels foamed -in -place with HFC -134a polyurethane insulation which is CFC and HCFC free • 26" wide, self closing door • Heavy duty adjustable cam -lift hinges • Spring actuated door closer • Deadbolt locking handle with independent key /pad lock feature and inside safety release • Magnetic gasket • Digital thermometer • Floor double sweep gasket • Perimeter heater wire • Vapor -proof light • Switch and pilot light • Registered by UL to ISO 9001:2000 • NSF, UL flame spread 25 on all panels; UL and CSA electrical listing on door sections • UL and CSA electrical listing on complete Capsule Pak'" refrigeration systems • City of New York (MEA) listed • City of Houston listed • LA County listed • California State listed STANDARD FEATURES • Oregon State listed • USDA accepted • Fifteen year panel warranty • 18 month labor warranty • One year parts warranty INDOOR MODELS: • Hot gas condensate vaporizer OUTDOOR MODELS: • White membrane roof and trim • Refrigeration hood • Door hood (optional) • -20 °Fahrenheit ambient controls OPTIONAL FEATURES ** • U- shaped shelving system • Floor treadplate kit • Exterior ramp • Condensing unit air deflector kit • Heater kit for cooler located outdoors in below 32 °Fahrenheit ambient • Leak detector / alarm (may be a requirement in s areas) • Three phase electrical • Remote Capsule Pak'" refrigeration systems • Five year compressor warranty • CEC compliant models available - - additional lead maybe required • 220/50/1 electrical • CE approved models for international installations • 8' -4" & 8' -7" heights • Electric vaporizer (for Remote Capsule Pak *M applications) RECEIVED CITY OF TUKWILA AUG 31 2012 PERMIT CENTER time ** Most options are available two weeks from receipt of order. Please contact us for specific questions. � ge: * Some models ship in 5 or 10 days Mucho Burrito -South Center Food Court Smith & Greene Company Nor -Lake, Inc. Registered to ISO 9001:2000 L File No. A3204 SN.OIIVN181A103 '$ S213Z3321 J `S213.1003 mi1213)1001 aio SPECIFICATION Nor -Lake KLB7768 -C Item #:11 WALK -IN SPECIFICATIONS Kold Lockerr" walk -ins are built •,of modular panels, and are insulated with foamed -in -place HFC -134a polyurethane insulation which is CFC and HCFC free. Each panel is designed to ensure ease of installation, long term reliability and high insulating efficiency. A. All panels are -- manufactured with =male end female mating, rails to ensure proper alignment',' ,during installation.. The polyurethane: insulation wraps around the return bend metal seams on` both section to create a light weight,panel of exceptional strength and durability.- AIL panels are a full four (4) inches thick and provide a superior insulating value. ' B. The foamed -in -place cam- locking;:xfasteners ensure an airtight seal for maximum ,energy. efficiency. C. Kold LockerTM : panel gaskets around•`fhe outer : perimeter of the panel are continuous, without cuts or breaks at corners: The Nor -Lake patented gasket design provides a- ,foamed -in -{ place gasket as an integral part of the_`panel. Gaskets cannot fall off or pull offfduring'shipment` or installation. D. Panels lock together tightly to assure an energy efficient walk -in. E. Edge caps for ends of floor and ceiling panels are foamed -in -place rather than . overlapped ormechanically fastened. Edge caps cannot come loose, and they stay in place - though the life of the walk -in. F. Panel Finishes: Interior and exterior complete to be 26 gauge corrosion resistant stucco embossed temper passed coated steel. Models supplied with a floor will include a smooth aluminum interior floor. surface. Insulation: Panels to be four (4) inches thick, metal "clad and foamed -in -place with :HFC -134a polyurethane . insulation which is CFC and HCFC free. " Mini Kold LockerTM Walk -ins 3'6" x 6'0" x 6'7" and 3'6" x 7'O" x 6'7 Similar floor space as 3 door'' reach -in. Modular -easy to get into existing building, through doors and hallways. 20 % -30% more capacity than 3 door reach -in. Expanded Kold LockerTM Coolers: Now three larger coolers are in stock for Same Day Shipment: 6'x14', 8'x12',. 8' x 14' Single Compartment Mucho Burrito -South Center Food Court A. B. C. D. E. Kold LockerTM Single Room Coolers or Freezers Floor Plan Layouts 6x8 3.5x6 • 3.5x7 3'6"/6 3'6"/7 46 . 4x6 46 6x10 45 46 48 6x6 66 F. 66 661 662 583 E70 I 5101 E102 E'. 23 612 II u 6121 6122 6123 6124 6125 88 614 6 8 6141 6142 6143 14 6144 11 6145 881 882 810 812 8121 8101 8 12 6123 814 8141 * 5 Day Ship 8142 8143 8.10 8102 6146 6147 8103 8104 8105 8x14 8144 67,:5 8126 8127 8145 8146 8147 8148 Smith & Greene Company Page: 3 8149 Nor -Lake DOOR Door sections manufactured at Nor -Lake are factory tested to assure proper fit, performance and alignment. All 'doors feature a stepped profile design that serves as a barrier to air flow which results in an energy efficient door system. . Each Kold LockerTM walk -in compartment is equipped with a 26" wide door. the height of the door opening varies with the series of .Kold. LockerTM ;walk -in; ordered. The 45 Series has 'a 59" door, the Standard Series (6'7" high). has a 66" high door and the 74 and. 77 Series Kold LockerTM walk -ins have a 78; -. high door. The door is self-closing, flush mounted, infitting and .:constructed to incorporate heavy duty, molded ABS' breaker, which is permanently foamed-in-place. KLB7768 -C Item #:11 Doors are a'ailable'with right `orleft side hinges and include two cam- lift,hinges, top hinge field : adjustable,with ;locking set . screw, spring actuated door closer, NL 9800 deadbolt locking handle with independent key /padlock feature and inside safety release. The doors are pre -hung in a four foot wide frame panel which is equipped with replaceable perimeter heater wire, magnetic stainless steel trim, digital thermometer, vapor -proof light fixture and switch with exterior pilot . indicator light. The door section is completely' pre- wired within concealed conduit inside the door frame panel. 115/60/1 electrical is field wired to a junction box which is surface mounted on the interior frame above the vapor proof light fixture. Hinges and door handle are mounted to 1/2" synthetic insulated ;tapping plates. Each door section is complete with a heavy gauge galvanized steel ;heated threshold. FLOOR CONSTRUCTION Floor panels (when supplied) are similar in construction to the wall panels except they are made to withstand uniformly distributed floor loads of up to 800 pounds per square foot. The interior floor metal is smooth aluminum. The 74 Series, floorless models, are supplied with a patented vinyl floor sealer to stop conductivity at floor level. This unique sealer sits flat on existing floors and fits tightly against the interior /exterior wall panels. The walk -in wall panel is supported on the shoulder of the sealer so the foam edge is free of compressing weight. The vinyl floor sealer is NSF list- Mucho Burrito -South Center Food Court DOORS FEATURE A STEPPED PROFILE DESIGN VAPOR PROOF LIGHT FIXTURE SPRING ACTUATED DOOR CLOSER DEADBOLT LOCKING HANDLE NL 9800 Deadbolt locking handle with independent key /padlock feature and inside safety release. FLOORLESS MODELS ARE SUPPLIED WITH A PATENTED VINYL FLOOR SEALER Smith & Greene Company Page: 4 Nor -Lake KLB7768 -C Item #:11 IL /-%L 7rCL•11- 11LAllVNJ OUTDOOR MODELS: All Kold LockeriM walk-ins installed outdoors include a weather protection kit consisting of: One piece; 35 mill, white membrane roof material which requires no seaming or gluing,to the top of the Kold LockerTh , ,walk -in ceiling panels. Plastic strips for;_ -; flashing the membrane.,: roofmaterial.to' the side of the Kold °LockerT"' walk -in wall panels are included.; Trim is secured to the Kold- LockerTM wall panels,with self drilling and self tapping TEK screw's. In °applications where the Kold Locker ?"" `walk -in: is installed - next to'a abuilding', the trim can be used to secure -the turned up membrane roof material —to . the building wall, with fasteners supptied by the equipment:;installer. , Above door rain hoods are an ;option and should be included on. installations where the door panels" are =exposed to the outdoor weather APPROVALS : Kold LockerTM walk ins construction is approved by s the 'National Sanitation Foundation' and shall have the N.S.F. seal on the door section. Walk -in panels shall have a U.L. flame spread rating of 25. The door section is U.L. : and C.S.A. listed for electrical safety...: • Registered by UL to. ISO 9001 • City of New York (MEA) listed • City of Houston listed;; • LA County listed • California Sate listed • Oregon State listed • USDA accepted • CEC Nor -Lake, Inc.. Registered to ISO 9001:2000 File No. A3204 Mucho Burrito -South Center Food Court 2 3/4 "- 1 8 63/8" 6'0" (45 Series) 67" (STD Series) 7'3 5/8" (74 Series) 7'7"(77 Senes) 6'7" HIGH 1.1141 19168100 CUBAGE KL45(6'0" High) 77 KL46 105 KL66 168 KL68 231 KL610 295 KL612 357 KL614 420 KL88 318 KL810 404 KL812 490 KL814 578 7'4" HIGH & 7'7" HIGH IJi/JI 111160108 CUBAGF KL7745 100 KL7746 KL7766 KL7768 KL77610 KL77612 KL77614 KL7788 KL77810 KL77812 KL77814 123 196 270 344 418 490 372 473 574 675 Door Opening Size W H Model 26" 59" 45 Series 26" 66" STD Series 26" 78" 74 Series 26" 78" 77 Series Corresponding Capsule PakTM Refrigeration System Kold Locker Model 38 °F -35 °F 38 °F -35 °F -10° Ceiling Wall Ceiling -10° Wall -20° Ceiling KL45 501 050 060 060 N/A KL366 501 050 050 060 N/A KL367 501 050 050 060 N/A KL46 501 050 060 060 100 KL66 501 050 075 075 100 KL68 050 050 100 100 150 KL610 050 050 100 100 150 KL612 751 075 150 150 150 KL614 100 N/A N/A N/A N/A KL88 050 050 100 100 150 KL810 751 075 150 150 150 KL812 100 N/A N/A N/A N/A KL814 100 N/A N/A N/A N/A 1.1,7746 501 050 075 075 N/A KL7748 050 N/A 100 N/A N/A KL7766 501 050 100 100 150 KL7768 050 050 100 100 150 KL77610 751 075 150 150 150 KL77612 751 075 150 150 151 KL77614 100 N/A N/A N/A N/A KL7788 751 075 150 150 150 KL77810 751 075 150 150 151 KL77812 100 N/A N/A N/A N/A KL77814 100 N/A N/A N/A N/A KL7446 050 050 N/A N/A N/A KL7466 050 050 N/A N/A N/A KL7468 751 075 N/A N/A N/A KL74610 751 075 N/A N/A N/A KL74612 075 075 N/A N/A N/A KL74614 100 N/A N/A N/A N/A KL7488 075 075 N/A N/A N/A KL74810 075 075 N/A N/A N/A KL74812 100 N/A N/A N/A N/A KL74814 100 N/A N/A N/A N/A KOD45 501 050 060 060 N/A KOD46 501 050 075 075 N/A KOD66 050 050 100 100 N/A KOD68 751 075 100 100 N/A KOD610 751 075 150 150 N/A KOD612 751 075 150 150 N/A KOD614 100 N/A N/A N/A N/A KOD88 751 075 150 150 N/A KOD810 751 075 150 150 N/A KOD812 100 N/A N/A N/A N/A K0D814 100 N/A N/A N/A N/A K0D7746 751 050 075 075 N/A KOD7766 751 075 100 100 N/A KOD7768 751 075 150 150 N/A K0077610 751 075 150 150 N/A KOD77612 075 075 150 150 N/A KOD77614 100 N/A N/A N/A N/A KOD7788 075 075 150 150 N/A KOD77810 075 075 151 151 N/A KOD77812 100 N/A N/A N/A N/A KOD77814 100 N/A N/A N/A N/A • Consideration must be given to accessibility for service 8 free condenser air flow. Consult Factory. Smith & Greene Company Page: 5 -20° Wall N/A N/A N/A 100 100 150 150 150 N/A 150 150 N/A N/A N/A N/A 150 150 150 150 N/A 150 150 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 1--W H EEEE F 7'4" HIGH & 7'7" HIGH IJi/JI 111160108 CUBAGF KL7745 100 KL7746 KL7766 KL7768 KL77610 KL77612 KL77614 KL7788 KL77810 KL77812 KL77814 123 196 270 344 418 490 372 473 574 675 Door Opening Size W H Model 26" 59" 45 Series 26" 66" STD Series 26" 78" 74 Series 26" 78" 77 Series Corresponding Capsule PakTM Refrigeration System Kold Locker Model 38 °F -35 °F 38 °F -35 °F -10° Ceiling Wall Ceiling -10° Wall -20° Ceiling KL45 501 050 060 060 N/A KL366 501 050 050 060 N/A KL367 501 050 050 060 N/A KL46 501 050 060 060 100 KL66 501 050 075 075 100 KL68 050 050 100 100 150 KL610 050 050 100 100 150 KL612 751 075 150 150 150 KL614 100 N/A N/A N/A N/A KL88 050 050 100 100 150 KL810 751 075 150 150 150 KL812 100 N/A N/A N/A N/A KL814 100 N/A N/A N/A N/A 1.1,7746 501 050 075 075 N/A KL7748 050 N/A 100 N/A N/A KL7766 501 050 100 100 150 KL7768 050 050 100 100 150 KL77610 751 075 150 150 150 KL77612 751 075 150 150 151 KL77614 100 N/A N/A N/A N/A KL7788 751 075 150 150 150 KL77810 751 075 150 150 151 KL77812 100 N/A N/A N/A N/A KL77814 100 N/A N/A N/A N/A KL7446 050 050 N/A N/A N/A KL7466 050 050 N/A N/A N/A KL7468 751 075 N/A N/A N/A KL74610 751 075 N/A N/A N/A KL74612 075 075 N/A N/A N/A KL74614 100 N/A N/A N/A N/A KL7488 075 075 N/A N/A N/A KL74810 075 075 N/A N/A N/A KL74812 100 N/A N/A N/A N/A KL74814 100 N/A N/A N/A N/A KOD45 501 050 060 060 N/A KOD46 501 050 075 075 N/A KOD66 050 050 100 100 N/A KOD68 751 075 100 100 N/A KOD610 751 075 150 150 N/A KOD612 751 075 150 150 N/A KOD614 100 N/A N/A N/A N/A KOD88 751 075 150 150 N/A KOD810 751 075 150 150 N/A KOD812 100 N/A N/A N/A N/A K0D814 100 N/A N/A N/A N/A K0D7746 751 050 075 075 N/A KOD7766 751 075 100 100 N/A KOD7768 751 075 150 150 N/A K0077610 751 075 150 150 N/A KOD77612 075 075 150 150 N/A KOD77614 100 N/A N/A N/A N/A KOD7788 075 075 150 150 N/A KOD77810 075 075 151 151 N/A KOD77812 100 N/A N/A N/A N/A KOD77814 100 N/A N/A N/A N/A • Consideration must be given to accessibility for service 8 free condenser air flow. Consult Factory. Smith & Greene Company Page: 5 -20° Wall N/A N/A N/A 100 100 150 150 150 N/A 150 150 N/A N/A N/A N/A 150 150 150 150 N/A 150 150 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A KLB7768 -C Mucho Burrito -South Center Food Court Item #:11 KOLD, LOCKERTM' WALK -IN SIZES AVAILABLE SINGLE COMPARTMENT SIZES; The 45 Series is available in one size which.' is 4' wide x 5' long x 6' -0" high. This model is supplied with a walk -in floor. This series ships in 5 days. The Standard Series of Kold LockerTM walk - insure all 6' -7" high and are all supplied with a floor. The sizes available are as follows: - 4' wide x 6' long, 6' wide x 6' long, 6' wide x 8'. long, 6' wide x 10' long, 6' wide x 12' long, 8' wide x 8' long, and 8' wide x 10' long. The 77 Series of Kold LockerTM -walk -ins are all 7 7" „high- and,are all supplied with:aa floor. The sizes available are as follows: 6' wide x 6' long, 6' wide x 8' long, 6' wide'x 10' long, 6'r�`. wide x.12' long, 8' wide x 8' long, and 8' wide x 10' long. The 74 Series of Kold LockerTm walk -ins are. all 7' -3 5/8” high and are all supplied without a floor. Wall panels are Installed on top of N.S.F listed vinyl sealers provided. The sizes available are as follows: 6' wide x 6' long, 6' wide x 8' long, 6' wide x 10' long, 6' wide x 12' long, 8' wide x 8' long, and 8' wide, x 10', long. COMBINATION KOLD LOCKERTM COMPARTMENT SIZES: The . Kold LockerTA4. combination. cooler / freezer line is available in 6' -7" high and 7' -7" high models and are all supplied complete with a floor. All models are available in two widths, 6' wide and 8' wide. The overall length of the combination Kold LockerTM is determined by the size of the cooler compartment and freezer compartment desired. The available: sizes are the same as available in' mat- ing single compartment models. EXAMPLE #1: If you have determined that you need a 6' wide combination model your choices for cooler and freezer compartment lengths are 6', 8', 10' and 12'. Therefore, if you desire both cooler and freezer to have lengths of 8' your overall combination dimensions will be 6' wide x 16' long. EXAMPLE #2: If you have determined that you need an 8' wide combination model your choices for cooler and freezer compartment lengths are 6', 8', and 10'. Therefore, if you desire the cooler to be 8' long and the freezer to be 6' long, your overall combination dimensions will be 8' wide x 14' long. Smith & Greene Company Page: 6 Nor -Lake SHELVING KITS Shelving kits specifically designed : for each Kold LockerTM walk -in configuration = are I offered as an optional extra. These kits are shipped with. the Kold Locker-r"" walk -in and. Capsule Pak."'" refrigeration' system so that all , necessary •omponenets are at your location, promptly when you need them the shelving, sets are coded to correspond-to the Kold.' LockerTM r walk -in configuration ordered -and are offered in either three or four tier. KLB7768 -C Item #:11 TWO TYPES .OF SHELVING .SYSTEMS ARE AVALIABLE ;FROM NOR-LAKE.' A. Green KoteTA° Shelving, „Green epoxy. .1 coated shelves.: 15. year guarantee against .1 corrosion. B. Nor -Lake Standard Chrome• =KoteTM Shelving. Shelving system construction ,is identical. Select the shelving FINISH of your choice. Shelving posts are engineered for maxium strength. Shelves are adjustable on 2" centers. Alt•shelves are N.S.F listed and are zinc coated with a heavy layer of Protoxy for a maximum life span under humid storage conditions. Special clips are utilized to gain the maxium square footage: of storage space for each Kold LockerTM model. _14 ", 18" and • 24" wide shelves are used as , required for maximum storage capacity in each set. This wire shelving is ideal for storage of all refrigerated or frozen products -' SHELVES: Shelves to, have #9 (.148 ") guage crosswires spaced 3/4" on centers with crossbraces 1/4" (.192 ") minimum of 4 -3/4" on center. Shelf Frames Channel to be 9/16" x 1" x .075" thick. Shelf Collars A round tapered 1 -5/16" high -steel collar to be welded at each corner. FINISHES A. Green KoteTm: Electrostatically applied green baked epoxy over zinc steel and brite basic wire. Thickness : 4-7 mill. B. Chrome KoteTM: Plated quality wire and steel. Surface nickel chrome plated. POSTS Posts to be..062" thick 1" O.D. round tubing notched every 2 on each corner of the post. POST LEVELERS Installed on the bottom of each post is nylon housing for -a steel leveler 3/8 " -16 x 1 -3/4 ". FINISHES A. Green KoteTM: Electrostatically applied green baked epoxy over zinc steel and brite basic wire. Thickness :'2 -3 mill. B. Chrome KoteTM: Plated quality wire and steel. Surface nickel chrome plated. Mucho Burrito -South Center Food Court 6' 0" 6' -0 /072r00) 10' 0" 6' 0" 18 x60 SHELF • ....,.. 7 110'77. 24.24 $HELP iiii 14 — SHELF CUP (2 PER TIER) Cl ., ' 18 x60' SHELF /072r00) 10' 0" 6' 0" NOR -LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016 800- 955 -5253 715- 386 -2323 800- 388 -5253 PARTS /SERVICE • 715- 386 -4292 FAX www.norlake.com 9001 .2 Registered to ISO 9001:2000 File No. A3204 Smith & Greene Company • Lt .11irz'g:,..., .t • ....,.. 7 110'77. 0 lir .7... ,...... NOR -LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016 800- 955 -5253 715- 386 -2323 800- 388 -5253 PARTS /SERVICE • 715- 386 -4292 FAX www.norlake.com 9001 .2 Registered to ISO 9001:2000 File No. A3204 Smith & Greene Company • Lt 1` = 01 TI • ST1— = v1 to m 7 18 x24 SHELF • = _' PER 1102 (2 PER 'i'cn) -i POST (10 REQ'D) Standex NORLAKE © 2006 NOR -LAKE, INC. Printed in U.S.A. Part Number: 079297 Revision Date: 2/06 Page: 7 1111PERMir COORD COP. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -122 PROJECT NAME: MUCHO BURRITO SITE ADDRESS: 971 SOUTHCENTER MALL DATE: 08/31/12 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued E ART E T: O s L f C at611_ B it ing Division 1 ire Prevention Public Works ❑ Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Complete DUE DATE: 09 /04/12 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/02/12 Approved ❑ Approved with Conditions k Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople Per Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MODCO DESIGN LLC 7146974354 16125 Juanita Woodinville #702 Bothell WA 98011 King Limited Liability Company UBI No. 603098736 Status Active Way License No. MODCODL895LT License Type Construction Contractor Effective Date 6/30/2011 Expiration Date 6/30/2013 Suspend Date Specialty 1 General Specialty 2 Unused Business Owner Information Name Role Effective Date Expiration Date MOROSHAN, JACOB Partner /Member 06/30/2011 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 AEGIS SECURITY INSURANCE COMPANY 520574 06/20/2011 Until Cancelled $12,000.00 06/30/2011 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 Nevada Capital Ins Co 77 NPP 4- 025711 05/02/2012 05/02/2013 $1,000,000.0005 /11/2012 2 Co Shield Ins CNT 017338 10/11/2011. 10/11/2012 05/22/2012 $1,000,000.00 10/21/2011 1 Underwriters at Lloyds A1Q924993 06/20/2011 06/20/2012 09/29/2011 $500,000.0006/30 /2011 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 09/10/2012 k a / /l / / /!J / /J/ , ////// z///m." ,, /./I///1 / / / /i / /! / //r / /izarr-r 1 war.. / / / / /!- „Arm/...m.r // // // // / /// .r ∎m /!1! / / /J// /f! /IY// /,f.r.w /il /.emar ∎ D AIL1D AIL1 "WALK -IN” COOLER BY MANUFACTURER DETAIL 1 STEEL L SUPPORT CURB AT (2) EXPOSED SIDES ■■m..NIN MN IMiINI noon No on SEPARATE PERMIT REQUIRED FOR: 0 Michankcat IS) Electrical gPlumbing Gas PO/ City of Tukwila BUILDING DIVISION 4 A d- a 4 • e1 WALK-IN COOLER WALL at Mop TftusS 5c+¢ew I'IZ x 1'I,' stEEc. � 1 1Z CoNcc. Pl&is 4• • DETAI REVISIONS No changes shall he made to the scope of work without prior approval of Tukwila Building Division_ NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SCALE: 1 1/2" = 1' -0" COOLER PLAN & DETAIL M3 ALL MAMMAL HERM CONSTRUES THE ORIGINAL WORK OFTHE ARCHITECT ANO MAY NOT SE USA PUBLISHED, D6CI.o6m OR RO'RODUC:a WIItiOUTTHE nitRTEN COIZENT OFTHIE ARCHITECT CCPYWRICHT LIGHT ARCHi}T IuRE & JAMB MIL ARCHITECT 2011 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 7 2012 City of u ila BUILDING I ISION FILE COPY Permit I1o.. p■1.-- Plan review approval is subject to errors and omissions. of constructioydocuments does not authorize th :. violation of any as f4 ed code or ordinance. Receipt of approved Field \ and conditions is acknowledged: B Date: City Of Tukwila BUILDING DIVISION RECEIVE) CITY OF TUKVVIL.A, AUG 312012 PERMIT CENTER M.12-122