MECHANICAL PERMIT
Parcel No.: 3348401682
Address: 5003 S 113 ST TUKW
Project Name: CAJIGAS & SUK RESIDENCE
Permit Number: M12 -128
Issue Date: 09/17/2012
Permit Expires On: 03/16/2013
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Email:
CAJIGAS ELMER +SUK WONG
529 244TH AVE NE , SAMMAMISH WA 98074
SHARYN PARKER
7277 PERIMETER RD S , SEATTLE WA 98108
S HRYN. PARKER @KING C OUNTY. G O V
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI9190A
Phone: 206 -296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS
.AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND
STRUCTURE, INCLUDING: SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE, AND
MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Mechanical: $2,256.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
Fees Collected: $177.10
International Mechanical Code Edition: 2009
Date:
D�I�1IV1�
I hereby certify that I have read and ex u:" d this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied 'th, hether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Signature: ,3 (__ e2 __ Date: 72/7"/-2—
Print Name: ZCG Cy c? o r
This permit shall become null ` and hid if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M12 -128 Printed: 09 -17 -2012
PERMIT CONDITIONS
Permit No. M12-128
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431- 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IMC -4/10
M12 -128 Printed: 09 -17 -2012
3g
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188 .
htto://www.TukwilaWA.gov
Mechanical Permit No.`f)4(a -
- Project No. �1 0(0
DateDate
Application Accepted:
Date Application Expires:
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *please print **
SITE LOCATION
33/-1 610- [tS
Site Address: 5003 S. 113th St.
Tenant Name:
Elmer Cajigas and Wong Suk
King Co Assessor's Tax No.:
Suite Number: Floor:
New Tenant: ❑ Yes .. No
PROPERTY OWNER
Name: Sharyn Parker, Program Manager
Name: Elmer Cajigas and Wong Suk
City: Seattle State: WA Zip: 98108
Address: 5003 S. 113th St.
Email: Sharyn.Parker @kingcounty.gov
City: Tukwila State: WA
Zip: 98178
CONTACT PERSON — person receiving all project ,' ,•;
. communication
Name: Sharyn Parker, Program Manager
Address: 7277 Perimeter Road South
City: Seattle State: WA Zip: 98108
Phone: (206) 296 -7437 Fax: (206) 269 -7315
Email: Sharyn.Parker @kingcounty.gov
84 79401 -366
MECHANICAL CONTRACTOR INFORMATION =,
Company Name: Tron Construction, Inc.
Address: 1705 S. 93rd St. / Unit F9
City: Seattle State: WA Zip: 98108
Phone: (206) 713 -8920 Fax: (425) 228 -2428
Contr Reg No.: TRONCCI9190A Exp Date: 09/01/2013
Tukwila Business License No.: BUS - 0993304
Valuation of project (contractor's bid price): $ 2,256
Describe the scope of work in detail:
This project has several components that involve upgrades of existing systems and does not require any physical changes to the
building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work
(windows, doors, insulation and abatement.)
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement ❑
Fuel Type: Electric ❑
Gas ❑
Other:
H:\Applications \Forms - Applications On Line\2011 Applications \Mechanical Permit Application Revised 8.9.1I.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended /wall /floor
mounted heater
Appliance vent
2
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
2
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood /gas stove
Emergency generator
Other mechanical
equipment
Boiler /Compressor
Qty
0 -3 hp/I00,000 btu
3 -15 hp /500,000 btu
15 -30 hp /1,000,000 btu
30 -50 hp /1,750,000 btu
50+ hp /1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN Oi
Signature:
Print Name
y J. Fenlason, Project Manager
Mailing Address: 4000 Delridge Way SW, Suite 200
Hi\Applications \Forms - Applications On Line \2011 Applications \Mechanical Permit Application Revised 8-9 -I 1 docz
Revised: August 2011
bh
Date:
Day Telephone: (206) 721 -0061
Seattle WA 98106
City State Zip
Page 2 of 2
City of Tukwila.
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206-431-3665
Web site: htt : //www.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R12 -02586
Initials: WER
Payment Date: 09/12/2012
User ID: 1670 Total Payment: 2,562.50
Payee: PAMELA K KUEHL (BY PHONE)
SET ID: mech SET NAME: KC Mechanical 9 -5 -12
SET TRANSACTIONS:
Set Member Amount
M12 -124 167.70
M12 -125 167.70
M12 -126 167.70
M� 1�2 -1y2'8 177.10
M12 -129 177.10
M12 -130 177.10
M12 -131 167.70
M12 -132 167.70
M12 -133 167.70
M12 -134 167.70
M12 -135 167.70
M12 -136 177.10
M12 -137 167.70
M12 -138 167.70
TRANSACTION LIST:
Type Method Description
Amount
Payment Credit C VISA 2,562.50
TOTAL: 2,562.50
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
MECHANICAL - RES 000.322.102.00.0
TOTAL:
2,562.50
2,562.50
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 ,„ (206) 431- 3670
Permit Inspection Request Line (206) 431 -2451
M t 2 ('Lg
Projec
Type of Inspeectio
Add,�ss: —
X 003
7/
113
Date Called:
Special Instructions:
Date Wanted:. p
t
` a.n
f ��.1 2..- -- �p.m.
Requester:
Phossr 5 _ :
07 2..•2
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
n -f (.Al , t ., tIA tkt-n
Inspector:
Date. : •
1'
F7 REINSPECTION FEE REQUIRED. f??or to next inspection,- fee must be .
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule_reinspection•:
•
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M12 -128 DATE: 09 -05 -12
PROJECT NAME: CAJIGAS & SUK RESIDENCE
SITE ADDRESS: 5003 S 113 ST
X Original Plan Submittal _
Response to Correction Letter # _
Response to Incomplete Letter #
Revision # After Permit Issued
BDEPARTMENTS: EPTM 61-1t-LL
�lildingDDiv sion II Fire Prevention ❑ Planning Division
Public Works ❑ Structural n Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
DUE DATE: 09-11 -12
Complete Incomplete ❑ Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUESITHURS ROUTING:
Please Route
Structural Review Required
❑ No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved El
with Conditions Not Approved (attach comments) n N/
Notation:
REVIEWER'S INITIALS: DATE:
DUE DATE: 10 -09 -12
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople -ter Friendly Page
General /Specialty Contractor
A business registered as a construction contractor with LIi1 to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCCI9190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135931
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
5
Landmark
American Ins Co
LHA135931
03/01/2012
03/01/2013
$1,000,000.00
03/06/2012
3
Landmark
American Ins Co
LHA135245
03/01/2011
03/01/2012
$1,000,000.00
03/07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.00
03/10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01 /2009
03/01 /2010
$1,000,000.00
08/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions /Citations Information No records found for the previous 6 year period
https: // fortress .wa.gov /lni/bbip/Print.aspx
09/17/2012
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
H VAC
HW
H WC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
M TG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ABBR DESCRIPTION
OR M
0
X/Y -
1
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9
REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4' -O" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
it PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
SYMBOL
XXX
DN I
+ f +
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VD
RA /EA
RG
SA
SA
RA /EA
SD
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
TOR THERMOSTAT
EQUIP ID EQUIPMENT LOCATION
NG
•
0
D'4
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
DESCRIPTION
VOLTS
PH
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
15
16
15
16
N/A
15
16
N/A
BV -1, 2
BLENDING UNIT VENTILATOR
120
1
X
7"
7"
X
WALL CAP
1, 2, 3, 4
X
90
1,2
-
SWITCHES (ON, TIMER)
120
1
1, 2, 3, 4
X
25
X
4"
4"
X
DECO
1
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
140
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
BV -2
115
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
2
SG -1
140
GO8" WG
8"
8"
CEILING
ALGRILLE
1, 2, 3
SG -2
115
GO8" WG
7"
7"
CEILING
ALGRILLE
1, 2, 3
OG -1
90
CO8" WG
7"
7"
WALL
WALL CAP
1, 2, 3, 4
00 -2
90
CO8" WG
7"
7"
WALL
WALL CAP
1, 2, 3, 4
RG -1
25
<08" WG
4"
4"
CEILING
DECO
1, 2, 3
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1935 BV -1
856
2
90 CFM
90 CFM
1
0810.03.1935 BV -2
825
1
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE INOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
SEPARATE PERMIT
REQUIRED FOR:
❑ Mechanical
QJecrical
(*umts *
C `Gas Piping
City of Tukwila
BUILDING DIVISION
FILE COPY
Permit No % I ' t2 g
Plan review approval is subject to errors and omissions.
tippro ai of construction documents does rcl auth.tA
thc ; oiation of any adopted code or ordinance. ; wcc t
nF approved Field Copy and conditions is acknowiedg 'd:
By
Date:. % /?•%
City Of Tukwila
BUILDING DIVISION
THERMOSTAT /SWITCH HOURS OF OPERATION
SET BV -1 SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
SET BV -1 SWITCH TO OPERATE 1 OF EVERY 3 HOURS.
REVIEWED FOR
400AE PP ROVED
NCE
SEP 12 2012
City of Tukwila
BUILDING DIVISION
BV—
MECHANICAL VENTILATION CALCULATION
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) 4
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION La
QF = 45 / (1 X 1 /2) = 90 CFM
BV-2 MECHANICAL VENTILATION CALCULATION
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) IQ
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION La
QF = 30 / (1 X 1 /3) = 90 CFM
REVISIONS
No changes shall be made to the scope
of \!work without prior approval of
'uk<rwila Building Division.
NOTC;.: Revisions will require a new plan submittal
and may include additional plan review fees. i
titp.-128
RECEIVED
CITY OF TUKWILA
SEP 0 5 2012
PERMIT CENTER
EXPIRES: 9/08/2012
STEMPER
A.RG.H.ITECTS
A Pragiossottattel WAWA WM4 %peeve
4£800 DELEIDGE WAY SW
SurrE 20 ° SEATTLE, WA 90100
(zoo) 424...an x3ax (200 ee4...pt
THE GREENBUSCH GROUP, INC
(soo y ' r U1E I IENRIE. 98119
209) 37l -O56 (200) 379 -0641 FM
081 0.03.1935
KING COUNTY INTERNATIONAL K
M R V M Ni
0
z
I
0
w
AIP NUMBER
3-53-0058444
0
0
4
ft—
DATE
961 6/11
ISSUED BID PACKAGE M-27
100% DD
PROJECT ENGINEER
DO
PROJECT MANAGER
IBC)
DRAWN
JA, DT
LEGENDS ,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1935
KITCHEN 2
LIVING- ROOM
1
TYP
5AT- OCM
t*-
D INING ROOM
SEE
5.1-1
140
WH
w
4.
UNDRY
1
L
IIM 2
SOFFIT, REFER TO
ARCHITECTURAL
25
SEE
TYP ALL
WALL GRILLES
TE DUCT IN JOIST BAY
8 "0 TO 12/4
DUCT TRANSITION
IOM 3
- SOFFIT, REFER TO
ARCHITECTURAL
4 "0
625 7"0
3 E
..i. a
CF.)vENI T 4.
BASEMENT MECHANICAL PLAN
IN JOIST
BAY
SCALE: 1/4" = 1' -0"
INSTALL PER THE
MANUFACTURER'S
WRITTEN INSTRUCTIONS
RETURN AIR
DUCT
OUTSIDE AIR
DUCT
16" MIN
HOLD TIGHT TO
STRUCTURE
FILTERS ACCESS
MOTOR ACCESS
USE EXISTING ATTIC
ACCESS HATCH FOR
ELECTRICAL AND
MAINTENANCE ACCESS
ArnC
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION,
2. INSULATE ALL DUCT AS SCHEDULED.
3. BV -1 INSTALLATION SIMILAR.
I31/-1 AND DUCTWORK EXPOSED IN LAUNDRY ROOM.
®BLENDING UNIT INSTALLATION DETAIL
SCALE: NONE
NORTH
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
OG -1
90
SEE
5
TYP
SEE
qG -2 -*
90
20° 30; (E.) ATTIC
ACCESS PANEL
L. IVING ROM
7 "0
5ATHROON
C2)
DUCT PER PLAN
(E)EG
KITCHEN
SEE M2 0 TYP
CEILING GRILLES
RG -1
25
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
CAULK
FOAM BACKER
ROD
WALL CAP OR
SIDEWALL GRILLE
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1/A2.2 FOR DETAIL.
WALL CAP INSTALLATION DETAIL
SCALE: ` NONE
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
DUCT PER PLAN
COORDINATE SOFFIT WITH
TECHNICAL REPRESENTATIVE
FIELD FABRICATE PLENUM
BEHIND CEILING GRILLE
CAULK
FOAM BACKER ROD
ARCHITECT TO PROVIDE 2X4
BLOCKING TO SUPPORT CEILING
CUTTING
FLOOR OR CEILING JOIST
CEILING
SLEEVE AND ESCUTCHEON
GRILLE
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S
WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
CEILING GRILLE INSTALLATION DETAIL
SCALE: NONE
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DRAWING NOTES:
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS
AT MINIMUM 10 FEET AWAY OR 3 FEET
BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER WAC 51- 52- 0403.8.3.
FLAG NOTES:
El V-1. AND DUCTWORK ROUTED EXPOSED.
BV -2 AND DUCTWORK ROUTED IN ATTIC. USE
EXISTING ATTIC ACCESS HATCH FOR ELECTRICAL
AND MAINTENANCE ACCESS.
ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER
SWITCH BY TECHNICAL SPECIFICATIONS SECTION
16100. AFFIX A LABEL TO THE CONTROLLER THAT
READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER WAC
51 -52- 0403.8.2 -5.8.
TRANSITION DUCT TO AIR TERMINAL NECK SIZE
IMMEDIATELY BEFORE MAKING FINAL GRILLE OR
DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS REQUIRED TO
INSTALL OUTSIDE AIR INLET. APPLY ACOUSTICAL
DAMPING COMPOUND TO INTERIOR FACES OF WALL
CAP. COORDINATE PAINT ON WALL CAP EXTERIOR
FACES WITH ARCHITECT. REFER TO
ARCHITECTURAL DRAWINGS AND TECHNICAL
SPECIFICATIONS.
INSULATE ALL DUCT AS SCHEDULED. REFER TO
THE MINIMUM DUCT INSULATION THICKNESS
SCHEDULE ON M1.0.
DUCT PER PLAN
CAULK
FOAM BACKER
ROD
WALL
GRILLE
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S
WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
WALL GRILLE INSTALLATION DETAIL
SCALE: NONE
.,ODE COMPLIANCE
APPROVED
SEP 12 2012
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
SEP 0 5 2012
PERMIT CENTER
EXPIRES: 9/08/2012
TE .R
yl,y'.PE
�. H. .I T E T
A Psvfavaiwara 114043ity Company
40016) DE GE WAY SW
Eur 3 NM • SEATTLE, WA OBOE
(200) 424-23777 PAX (204) 024- 2070
THE GREENBUSCH GROUP, INC
tt AUOEO vmm a t cHM1C1L DGPltERINO
(2OQ} 78—O5 9 61P�T ( ) 370— OQ41�FiMx
081 0.03. 935
ON AL AIRPORT
re
LU
0
0
Z
EDY IMPROVEMENTS
RESIDENTIAL AIRCRAFT NUS
AIP NUMBER
3-53-0058 -044
LA WASHINGTON
DATE
9/16 /11
ISSUED
BID. PACKAGE NI-27
100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
CEO
DRAWN
JA, DT
MECHANICAL
PLANS AND
DETAILS
M2.0
081 O.O P1935