HomeMy WebLinkAboutPermit M12-138 - NAKATA RESIDENCENAKATA RESIDENCE 11600 39 AV S M12-138 City *Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 7340600221 Address: 11600 39 AV S TUKW Project Name: NAKATA RESIDENCE Permit Number: M12 -138 Issue Date: 09/17/2012 Permit Expires On: 03/16/2013 Owner: Name: NAKATA KAZUO Address: 11600 39TH AVE S , SEATTLE WA 98168 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Email: SHRYN.PARKER @KINGCOUNTY.GOV Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI919OA Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE, AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Mechanical: $1,725.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Fees Collected: $167.70 International Mechanical Code Edition: 2009 Permit Center Authorized Signature: � Date: U ► l 1 I �. I hereby certify that I have read and governing this work will be complie ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pr construction or the performance of work. back of this permit. Signature: e to give authority to violate or cancel the provisions of any other state or local laws regulating am authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: 9"/71'2"" 1'2-' Print Name: G f G Ci ✓ e o' mot, This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -138 Printed: 09 -17 -2012 • • PERMIT CONDITIONS Permit No. M12-138 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -138 Printed: 09 -17 -2012 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.gov • Mechanical Permit No. Ott 1 t a- 17 Project No. 0--- -O ; ) Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION King Co Assessor's Tax No.: 7340600221 Site Address: 11600 39th Ave. S. Tenant Name: Sharon Nakata Suite Number: PROPERTY OWNER Name: Sharyn Parker, Program Manager Name: Sharon Nakata City: Seattle State: WA Zip: 98108 Address: 11600 39th Ave. S. Email: Sharyn.Parker @kingcounty.gov City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Sharyn Parker, Program Manager Address: 7277 Perimeter Road South City: Seattle State: WA Zip: 98108 Phone: (206) 296 -7437 Fax: (206) 269 -7315 Email: Sharyn.Parker @kingcounty.gov New Tenant: Floor: ❑ Yes m..No MECHANICAL CONTRACTOR INFORMATION Company Name: Tron Construction, Inc. Address: 1705 S. 93rd St. / Unit F9 City: Seattle State:. WA Zip: 98108 Phone: (206) 713 -8920 Fax: (425) 228 -2428 Contr Reg No.: TRONCCI9190A Exp Date: 09/01/2013 Tukwila Business License No.: BUS - 0993304 Valuation of project (contractor's bid price): $ 1,725 Describe the scope of work in detail: This project has several components that involve upgrades of existing systems and does not require any physical changes to'the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: H:WppltcatIons\Forms- Applications On Line \201 I Applications\ Mechanical Permit Application Revised 8 -9 -1 Ldocx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended /wall /floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system 1 Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND E THIS APPL e AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LA .. �' TH % ' OF WI. ' ►. NT: BUILDING OWNER O Signature: Print Name: Mailing Addres 10 - Fe . son, Project Manager /000 Delridge Way SW, Suite 200 ON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. H: \Applications \Forms - Applications On Line \2011 Applications \Mechanical Permit Application Revised 8 -9 -I I.docx Revised: August 2011 bh Date: Day Telephone: (206) 721 -0061 Seattle WA 98106 City State Zip Page 2 of 2 of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -02586 Initials: WER Payment Date: 09/12/2012 User ID: 1670 Total Payment: 2,562.50 Payee: PAMELA K KUEHL (BY PHONE) SET ID: mech SET NAME: KC Mechanical 9 -5 -12 SET TRANSACTIONS: Set Member Amount M12 -124 167.70 M12 -125 167.70 M12 -126 167.70 M12 -127 177.10 M12 -128 177.10 M12 -129 177.10 M12 -130 177.10 M12 -131 167.70 M12 -132 167.70 M12 -133 167.70 M12 -134 167.70 M12 -135 167.70 M12 -136 177.10 M12 -137 - 167.70 P1'1�21f318. o1P 1;16s'Z I7 0 f. TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 2,562.50 TOTAL:. 2,562.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - RES 000.322.102.00.0 2,562.50 TOTAL: 2,562.50 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION = ' 6300 Southcenter Blvd., #100, Tukwila: WA 98188 y:~ (206)_431 -3670 Permit Inspection Request Line (206) 431 -2451 Pr �>:: �� A" /-63 r Type`of In5E0 #`�J'. Jl ,� 1 ✓v1.0. Address: j_- 11 (z1,0 /) - Date Called: Special Instructions: r Date Wanted: 1 a:m, Requester: Phone No Approved per applicable codes. COMMENTS: ElCorrections required prior to approval. ferMt ( t nM1N Insp‘tor: Vh Date: .. .r. n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must .be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -138 PROJECT NAME: NAKATA RESIDENCE DATE: 09 -05 -12 SITE ADDRESS: 11600 39 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued EPAR MENTS: ul ding Division Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 09 -11 -12 Not Applicable n Comments: Permit. Center Use<'Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S IN IALS: DATE: Structural Review Required No further Review Required APPROVALS OR CORRECTIONS: Approved DUE DATE: 10-09 -12 Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Inter Friendly Page General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135931 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Landmark American Ins Co LHA135931 03/01/2012 03/01/2013 $1,000,000.00 03/06/2012 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.0003 /07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.0003 /10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.0008 /05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 09/17/2012 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR WB W/ W WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL 4(4) ABBR OR Z.X. 0 X/Y - DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE MTh ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 1O' -O" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG —X XXX —I-0 SSZSZZISSZI 0-, 0 4"- TOR f:p gQUIP ID #`•._ NG 1 ►1 • D 0 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD RA /EA RG SA SA RA /EA SD VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED. ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION — RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 430 GO8 "WG 8 "0 EXTERIOR 15 16 15 16 N/A 15 16 N/A — MOTOR OPERATED DAMPER 24 1 X X X 1,2 — THERMOSTAT 24 1 X X X 1 REMARKS: 1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 — DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR 150 430 GO8 "WG 8 "0 EXTERIOR 1,2 REMARKS: t INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2028 2062 4 150 CFM 150 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 GRILLE AND DIFFUSER SCHEDULE DUCT LOCATION 1 MIN VALUE (NOTES MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS REMARKS 1,3 IN CEMENT SLAB OR IN GROUND SG -1 1 75 1 <.08" WG 1 6" 1 6" 1 WALL 1 ALGRILLE 1 1, 2, 3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. REMARKS: t INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER t3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. SEPARATE PERMIT REQUIRED FOR: MebheniWll Refection, elii mbkv rOoMa Pig City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of vrork without prior approval of T ulmila Building Division_, ' < + ^TA: re1,!i^iens will require a new plan submittal °l may in:.'ude additional plan review fees. DRAWING NOTES: ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. FILE C P'Y Permit No. Plan review approval is subject to errors and omissions. A p mval of construction documents does not autilf.,riza tic violation of any adopted code or ordinance. Raceipt of approved Field Copy and conditions is acknowledged: By Date :. 7-17- iv City Of Tukwila BUILDING DIVISION THERMOSTAT HOURS OF OPERATION SET THERMOSTAT TO OPERATE 1 OF EVERY X HOURS. REVIEWED FOR LODE COMPLIANCE APPROVED SEP 12 2012 Olt City of Tukwila MECHANICAL VENTILATION CALCULATION PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / (&EGR X F) QR = (FROM TABLE 403.8.1) Z . &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 75 / (1 X 1/2) = 150 CFM M• X38 RECEIVpD CITY OF TUKWILA SEP 0 5 2012 PERMIT CENTpR 1 EXPIRES: 9/08/2012 1 P P STEM.PE.R ,.ARCHITECTS 400() DELKODGE WAY SW Sum SEMI' , W 961N (WO 41 r77 • Pia (2s» 424—E(e79 THE GREENBUSCH GROUP, INC .41..:«:..x:? 41r �11co Auoio vom • r uwcu oioraan io (200) 378 -05e9 sn� ' (2000) ii FM 081 0.03.2028 z LLI 0 0 0 AIP NUMBER 3- 534)058 -044 LA WA H H GT DATE 9/16111 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER D0 DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, DWG INDEX M1.0 0810.03 2028 CUT NEW HOLE ABOVE EXISTING, DO NOT RE -USE EXISTING HOLE EXISTING HCt_E FOR OLD FLUE TYP SG -1 75 INTO JOIST BAY r CONNECT TO EXISTING FAMILY ROOM [D SEE TYP ALL WALL GRILLES LAUNDRY ROOM BASEMENT MECHANICAL PLAN SCALE: 1/4" = 1' -0" CEILING VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING OUTSIDE AIR DUCT, SIZE AND ROUTE IN JOIST PER PLAN MOD, INTERLOCK TO FURNACE POC BEHIND (E) RETURN FLOOR stf NORTH OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE (E) E IR OM ErooI 2 24'x60 ° Tro, A a Asasa .ANE C.a•.•i A STUDY fBATIml 2 () 0 MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN 0 E CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL SCALE: NONE cliN NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE CAULK FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. WALL GRILLE INSTALLATION DETAIL DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51 -52- 0403.8.3. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51- 52- 0403.8.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51- 52- 0403.8.2 -5.8. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. SCALE: NONE ly8 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 12 2012 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 0 5 2012 PERMIT CENTER EXPIRES: 9/08/2012 ,11 STEMPER ARCHITECTS Profeadorats1 Otemgotioy 4002 DELRIDGE WAY WW SUITE 200 SEATTLE, WA 00180 (ow 04-0V77 • PAX (2O» 424-2078 THE GREENBUSCH GROUP, WC tt �aa m ' mco t IL HAM L D GI1 NO (0)378 -oae9 'sla (201) awe -oe41 3 0810.03.2028 O e z 0 z w z) O 0 EDP IMPROVEMENTS w O LL 0 L 0 L AIP NUMBER. 3-53-0058-044 DATE 4!16111 ISSUED BI() PACKAGE M-27 100% CD PROJECT ENGINEER DO PROJECT MANAGER [O DRAWN JA, DT MECHANICAL PLANS AND DETAILS M2.0 0810M.2028